Eternal Drive VECTOR-P100 Direct Current Variable Frequency Drive User Manual Version 1.0 September, 2022 LONGWEI AUTOMATIC VECTOR-P100 USER MANAL LONGWEI AUTOMATIC Updated records DCR# Rev. Originator Date 1 1.00 Dales Wong 10/10/2022 DC VARIABLE FREQUENCY DRIVE Remark Initial release 2 VECTOR-P100 USER MANAL LONGWEI AUTOMATIC Content 1.Electrical specifications 2.Installation and overall dimensions 3.Interface Definition 3.2 Left interface 3.2 Right interface 3.3 Dip switch diagram and speed setting table 4.Terminal control (I/O interface) 4.1 Input electrical schematic diagram 4.2 Output electrical schematic diagram (optional function) 5.Electrical connection mode 5.1 Wiring speed control PNP mode 5.2 Wiring speed control NPN mode 5.3 Multiple drivers are connected to PLC in PNP mode 5.3.1 Multiple drive RUN port connect to PLC in PNP mode 5.3.2 Multiple drive VERTOR-P100 port connect to PLC in PNP mode 5.4 Multiple drive connect to PLC in NPN mode 5.4.1 Multiple drive RUN port connect to PLC in NPN mode 5.4.2 Multiple drive VERTOR-P100 port connect to PLC in NPN mode DC VARIABLE FREQUENCY DRIVE 3 VECTOR-P100 USER MANAL LONGWEI AUTOMATIC 1. Electrical specifications Item Unit Drive model number Specifications VECTOR-P100 With Hall sine wave control Drive brushless mode Rated voltage V DC24±5% Peak current A 10 Rated power W 100 Working form % 100 Control mode Installation sizes S1: continuous working form I/O signal mm Power interface Terminal control interface Motor and Hall interface Working temperature Remark ℃ Working humidity DC VARIABLE FREQUENCY DRIVE 92mm×36mm 2 core screw access socket Nylon (PA66), UL94V-2/0 2 core screw access terminal phosphor bronze (C5191), cable: RVV 2X1.0mm² 6 core screw access socket Nylon (PA66), UL94V-2/0 6 core screw access terminal phosphor bronze (C5191), cable: ZR-RVSP 0.5mm² 9 core square socket Nylon (PA66), UL94V-2/0 9 core square terminal phosphor bronze (C5191), cable: RVV 2X1.0mm² -10~40 below 85% no water drops, no rain 4 VECTOR-P100 USER MANAL LONGWEI AUTOMATIC 2. Installation and overall dimensions (figure 1 drive dimensions unit: mm) 3. Interface Definition power input motor interface functional dip alert lamp control interface (figure 2 drive interface definition) DC VARIABLE FREQUENCY DRIVE 5 VECTOR-P100 USER MANAL LONGWEI AUTOMATIC 3.1 Left interface description (figure 3 the left interface) Power input No. Item Functional Definition Remark 1 VIN+ DC24V positive input Input voltage range: DC24V ±5% 2 VIN- DC24V negative input Current: Rated current is divided into 3A and 4.2A Motor interface No. Item Functional Definition Remark 1 U motor U phase connect to reduction motor U phase (ref: yellow wire) 2 V motor V phase connect to reduction motor V phase (ref: green wire) 3 W motor W phase connect to reduction motor W phase (ref: blue wire) 4 ENV- power ground Hall power negative pole (ref: black wire) 5 ENV+ +5V Hall power Hall power positive pole (ref: red wire) 6 TEMP temperature sensor NTC signal temperature sensor NTC signal (ref: white wire) 7 HA Hall signal A connect to reduction motor Hall signal A (ref: yellow wire) 8 HB Hall signal B connect to reduction motor Hall signal B (ref: green wire) 9 HC Hall signal C connect to reduction motor Hall signal C (ref: blue wire) 3.2 Right interface description (figure 4 DC VARIABLE FREQUENCY DRIVE the right interface) 6 VECTOR-P100 USER MANAL LONGWEI AUTOMATIC Control interface No. Item Functional Definition Remark 1 EEROR-N in case of failure, output 0V in case of without failure, output is +24V 2 EEROR-P in case of failure, output 24V in case of without failure, output is +24V Default disconnection: clockwise 3 REVERSE motor running direction signal Connected to the common terminal 0V or the power positive pole +24V: counterclockwise 4 RUNA run input signal A 5 RUNB run input signal B 6 COMMON common terminal power supply 0V Functional dip No. Item Functional Definition Remark 1 DIP-1 speed setting refer to annexed table 1 2 DIP-2 speed setting refer to annexed table 1 3 DIP-3 speed setting refer to annexed table 1 4 DIP-4 speed setting refer to annexed table 1 5 DIP-5 speed setting refer to annexed table 1 6 DIP-6 current setting default OFF: 3A, ON: 2A 7 DIP-7 brake setting default OFF: EABS, ON: servo brake 8 DIP-8 speed acceleration/deceleration Setting refer to annexed table 2 9 DIP-9 speed acceleration/deceleration Setting refer to annexed table 2 10 DIP-10 Direction setting default direction OFF: clockwise, ON: counterclockwise Note: When the outlet wire of the drum motor is connected to the drive or the extension end, it is necessary to plug the connector tightly, so that the white positioning line of the male head is completely covered by the female head (the female head does not show the white line), and it is judged that the connector is firmly inserted. 3.3 Dip switch diagram and speed setting table The DIP switch ON/OFF position (figure 5 DC VARIABLE FREQUENCY DRIVE dip switch position) 7 VECTOR-P100 USER MANAL LONGWEI AUTOMATIC Note: The area where the dip switch and LED are located is protected by a transparent plastic cover. Open the protective cover outwards, set the corresponding dip switch, and fasten the protective cover tightly when closing the protective cover. Annexed table 1 Dip switch speed setting table (DIP1-5) DC VARIABLE FREQUENCY DRIVE 8 VECTOR-P100 USER MANAL LONGWEI AUTOMATIC Annexed table 2 Dip switch speed acceleration/deceleration setting table (DIP8-9) No. DIP-8 DIP-9 Acceleration/Deceleration Speed (second) 1 OFF OFF 2 2 ON OFF 1 3 OFF ON 0.5 4 ON ON 0.2 Status lamp No. Item Functional Definition Remarks fault-free: lights on 1 red LED power indicator fault alarm faulty: blink (0.5S blink at an interval of 1.5S) Once: Hall 3 times: overcurrent twice: temperature 4 times: locked-rotor 2 green LED Running status indicator DC VARIABLE FREQUENCY DRIVE 6 times: undervoltage 7 times: overvoltage fault-free: blink, faulty: lights off 9 VECTOR-P100 USER MANAL LONGWEI AUTOMATIC 4. Terminal interface (I/O interface) 4.1 Input electrical schematic diagram (figure 6 input electrical schematic diagram) Input interface No. 1 Item RUNA RUNB Functional Definition Remark run input signal 1.RUNA, RUNB, REVERSE control signal can be NPN (activelow), also can be PNP (active-high). 2 REVERSE motor running direction signal 3 COMMON common terminal (0v) DC VARIABLE FREQUENCY DRIVE 10 VECTOR-P100 USER MANAL LONGWEI AUTOMATIC 4.2 Output electrical schematic diagram (optional function) (figure 7 output electrical schematic diagram) Output interface No. Item Functional Definition Remark 1 ERROR-N run input signal 1. ERROR-N/ VERTOR-P100 Is the fault output point signal, the signal is constant on. 2. ERROR-N/ VERTOR-P100 is an open leakage output 2 point. When there is an output signal, ERROR-N and COM are connected, and VERTOR-P100 and VDD are VERTOR-P100 connected. 3. FO output maximum current limit 20mA, maximum voltage 72V. 3 COMMON common terminal (0v) 4 VDD Internal power supply DC VARIABLE FREQUENCY DRIVE 11 VECTOR-P100 USER MANAL LONGWEI AUTOMATIC 5. Electrical connection mode 5.1 Wiring speed control PNP mode Wiring Diagram RUNA RUNB Remark ON OFF Motor roller runs at a set speed of 100% OFF ON Motor roller runs at a set speed of 70% ON ON Motor roller runs at a set speed of 30% OFF OFF Motor roller stops running 5.2 Wiring speed control NPN mode Wiring Diagram RUNA RUNB Remark ON OFF Motor roller runs at a set speed of 100% OFF ON Motor roller runs at a set speed of 70% ON ON Motor roller runs at a set speed of 30% OFF OFF Motor roller stops running 5.3 Multiple drivers are connected to PLC in PNP mode DC VARIABLE FREQUENCY DRIVE 12 VECTOR-P100 USER MANAL 5.3.1 LONGWEI AUTOMATIC Multiple drive RUN port connect to PLC in PNP mode (figure 8 multiple drive RUNA port connect to PLC in PNP mode) Note: Figure 8 shows single PLC output points to the RUN A port of multiple drive. The same applies to RUN B and REVERSE. DC VARIABLE FREQUENCY DRIVE 13 VECTOR-P100 USER MANAL 5.3.2 LONGWEI AUTOMATIC Multiple drive VERTOR-P100 port connect to PLC in PNP mode (figure 9 multiple drive VERTOR-P100 port connect to PLC in PNP mode) Note: Figure 9 shows single PLC output points to the ERROR-P port of multiple drive. This input point is triggered when there is an error in any of the drive. DC VARIABLE FREQUENCY DRIVE 14 VECTOR-P100 USER MANAL LONGWEI AUTOMATIC 5.4 Multiple drive connect to PLC in NPN mode 5.4.1 Multiple drive RUN port connect to PLC in NPN mode (figure 10 multiple drive RUNA port connect to PLC in NPN mode) Note: Figure 10 shows single PLC output points to the RUN A port of multiple drive. The same applies to RUN B and REVERSE. DC VARIABLE FREQUENCY DRIVE 15 VECTOR-P100 USER MANAL LONGWEI AUTOMATIC 5.4.2 Multiple drive VERTOR-P100 port connect to PLC in NPN mode (figure 11 multiple drive ERROR-N port connect to PLC in NPN mode) Note: Figure 11 shows single PLC output points to the ERROR-N port of multiple drive. This input point is triggered when there is an error in any of the drive. DC VARIABLE FREQUENCY DRIVE 16