HAZARDOUS (Classified) LOCATIONS GUIDE for NORTH AMERICA Typical Equipment Marking for Divisions Enclosure Ingress Rating Comparisons Class Division Gas/Dust Groups Temperature Class Enclosure Type Rating Class I Div 1 Gas Groups A, B, C, D T4 Type 4X Class II Div 2 Dust Groups E*, F, G T135C —— North America Enclosure Type Ratings IEC 60529 Degree of Protection (IP) 2014/34/EU (ATEX) IEC NEC 500/505/506 Type 1 IP20 Group I (mining) Group I (mining) n/a Type 2 IP22 Group II (surface) Group II (surface, gas) Class I (gas + vapour) Type 3, 3X, 3S, 3SX IP55 Type 4, 4X IP66 “ Type 5 IP53 Group III (surface, dust) Class II (dust) —— Class III Type 6 IP67 Type 6P IP68 Type 12, 12K IP54 Type 13 IP54 *Group E Dust automatically indicates Division 1 Typical Equipment Marking for Zones Zone Standard: Ex (Canada) / AEx (US) Type of Protection Equipment Group Temperature Class Zone 21 AEx tb IIC T4 Protection Concept Comparisons Europe/IEC North American Zones North American Divisions (not exclusive) Flameproof (db) EN/IEC 60079-1 Flameproof UL/C22.2 60079-1 Explosion proof UL1203 / FM 3615 / C22.2 No.30 Intrinsic Safety (ia, ib) EN/IEC 60079-11 Intrinsic Safety UL/C22.2 60079-11 Intrinsic Safety UL913 / FM 3610 / C22.2 No. 60079-11 Purged + Pressurised EN/IEC 60079-2 Purged + Pressurised UL/C22.2 60079-2 Purged + Pressurised NFPA 496 / FM 3620 / ISA 12.04.01 Increased Safety (eb) EN/IEC 60079-7 Increased Safety UL/C22.2 60079-7 Increased Safety ISA 12.12.01 / C22.2 No.213 Encapsulation (ma, mb) EN/IEC 60079-18 Encapsulation UL/C22.2 60079-18 Encapsulation ISA 12.12.01 / C22.2 No.213 Powder Filling (qb) EN/IEC 60079-5 Powder Fillings UL/C22.2 60079-5 —— Oil Filled (ob) EN/IEC 60079-6 Oil Filled UL/C22.2 60079-6 —— Flameproof (dc) EN/IEC 60079-1 Flameproof UL/C22.2 60079-1 Enclosed Break ISA 12.12.01 / C22.2 No.213 Hermetically Sealed (nC) EN/IEC 60079-15 Hermetically Sealed UL/C22.2 60079-15 Non-incendive UL 12.12.01 / C22.2 No.213 Non-incendive (nC) EN/IEC 60079-15 Non-incendive UL/C22.2 60079-15 Non-incendive UL 12.12.01 / C22.2 No.213 Non-sparking (nA) EN/IEC 60079-15 Non-sparking UL/C22.2 60079-15 Non-incendive UL 12.12.01 / C22.2 No.213 Oil Filled (oc) EN/IEC 60079-6 Oil Filled UL/C22.2 60079-6 Restricted Breathing EN/IEC 60079-15 Restricted Breathing UL/C22.2 60079-15 —— Optical Radiation (op is) EN/IEC 60079-28 Optical Radiation UL/C22.2 60079-28 —— Trace Heating EN/IEC/IEEE 60079-30-1 Trace Heating IEC/IEEE 60079-30-1 Trace Heating IEC/IEEE (515) 60079-30-1 / C22.2 60079-30-1 Process Sealing EN/IEC 60079-40 Process Sealing UL/C22.2 60079-40 —— Special Protection (s) EN/IEC 60079-33 —— —— Flame Arrester EN/ISO 16852 Flame Arrester UL 525 —— Diesel Engines EN1834 (Part 41) Diesel Engines UL 122001 —— Caplights EN/IEC 60079-35 Caplights C22.2 60079-35 —— Dust Protection by Enclosure EN/IEC 60079-31 Dust Protection by Enclosure UL/C22.2 60079-31 Dust Protection by Enclosure UL 1203/3611/3616 / ISA 12.12.01 / C22.2 No.25 Non-electrical EN/IEC 80079-36/37 Hazardous (Classified) Locations Guide for North America v1.1 OTC 2022 Eurofins E&E NA Hazloc Poster v1.1 with address to print for OTC ONLY.indd 1 Temperature Class Comparisons (Gas & Vapours) NEC/CEC Divisions IEC / 2014/34/EU NEC/CEC Zones Temperature T1 T1 ≤450°C T2 T2 ≤300°C T2A “ ≤280°C T2B “ ≤260°C T2C “ ≤230°C T2D “ ≤215°C T3 T3 ≤200°C T3A “ ≤180°C T3B “ ≤165°C T3C “ ≤160°C T4 T4 ≤135°C T4A “ ≤120°C T5 T5 ≤100°C T6 T6 ≤85°C Note: This is a general comparison, where the type rating exceeds the equivalent IP rating. Type and IP rating are generally not interchangeable due to the differences in testing. Dust Group Comparisons 2014/34/EU (ATEX) IEC & NEC/CEC Zones IIIC IIIC IIIB IIIB IIIA IIIA NEC/CEC (ignitable fibres & flyings) NEC/CEC (combustible dusts) E n/a F —— G n/a n/a Class III Gas Group Comparisons 2014/34/EU (ATEX) IEC & NEC/CEC Zones NEC/CEC Divisions IIC IIC A/B IIB IIB C IIA IIA D —— —— Equipment Groups Category / Zones / Division Comparisons 2014/34/EU ATEX Category IEC Zones Equipment Protection Level (EPL) NEC/CEC Divisions NEC/CEC Zones 1G Zone 0 Ga Class I / Division 1 Class I / Zone 0 2G Zone 1 Gb Class I / Division 2 Class I / Zone 1 3G Zone 2 Gc Class I / Division 2 Class I / Zone 2 1D Zone 20 Da Class II / Division 1 —— Class III / Division 1 Class II / Zone 20 2D Zone 21 Db Class II / Division 2 —— Class III / Division 2 Class II / Zone 21 3D Zone 22 Dc Class II / Division 2 —— Class III / Division 2 Class II / Zone 22 —— Eurofins E&E North America (Austin) 13501 McCallen Pas TX 78753 Austin Eurofins E&E CML New Port Road Ellesmere Port, CH65 4LZ, UK +1 512.287.2500 info@metlabs.com www.metlabs.com +44 151 559 1160 sales@cmlex.com www.eurofins.co.uk/cml 12/04/2022 09:51:26