Concertor N100-5800 The most intelligent wastewater pump on the market. Suitable for customers operating traditional on/off pump stations who want to benefit from re-settable pump performance, clog detection and pump cleaning, soft start, constant power and motor protection. Technical specification Curves according to: [m] Head 32 31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 0 10 Water, pure [100%],4 °C,1000 kg/m³,1.569 mm²/s 80 [l/s] Curve: ISO 9906 Nominal (mean) data shown. Under- and over-performance from this data should be expected due to standard manufacturing tolerances. Please consult your local Flygt representative for performance guarantees. Configuration Motor number Installation type Impeller diameter Discharge diameter N6020.181 18-08-1AZ-W 5.5KW 20 30 40 50 60 70 P - Semi permanent, Wet 100 m m 200 mm Pump information Materials Impeller diameter Impeller 200 mm Hard-Iron Discharge diameter 100 mm Inlet diameter 150 mm Maximum operating speed 500-1945.4 rpm Number of blades 2 Max. fluid temperature 40 °C Project Block Created by Created on Xylect-20810356 0 Program version Data version User group(s) 69.0 - 15/05/2023 (Build 33) 28/06/2023 10:31 Xylem: Dubai - EXT 7/5/2023 Last update 7/5/2023 Concertor N100-5800 Technical specification Motor - General Motor number Phases Rated speed Rated power Approval Insulation class Rated current Type of Duty Frequency Rated voltage Motor efficiency class N6020.181 18-08-1AZ-W 5.5KW No 3~ 500-1945 rpm H 50 Hz 5.5 kW 9.6 A 380 V S1 IE4 according to IEC/TS 60034-30-2 Ed. 1 Motor - Technical Power factor - 1/1 Load Motor efficiency - 1/1 Load Power factor - 3/4 Load Motor efficiency - 3/4 Load Power factor - 1/2 Load Motor efficiency - 1/2 Load 0.95 90.0 % 0.95 91.0 % 0.95 91.0 % Nominal speed - 1/1 Load 2300 rpm Nominal speed - 3/4 Load 2070 rpm Nominal speed - 1/2 Load 1840 rpm Starting current 9.6 A Project Block Xylect-20810356 0 Created by Created on Program version Data version User group(s) 69.0 - 15/05/2023 (Build 33) 28/06/2023 10:31 Xylem: Dubai - EXT 7/5/2023 Last update 7/5/2023 Concertor N100-5800 Monitoring and Control equipment Project Block Created by Created on Xylect-20810356 0 Program version Data version User group(s) 69.0 - 15/05/2023 (Build 33) 28/06/2023 10:31 Xylem: Dubai - EXT 7/5/2023 Last update 7/5/2023 Concertor N100-5800 Performance curve Duty point Flow Head 40.1 l/s 10 m Curves according to: [m] 32 31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 [%]0 70 60 50 40 30 20 10 0 [kW] 8 7 6 5 4 3 2 1 [m] 16 14 12 10 8 6 4 2 Water, pure [100%],4 °C,1000 kg/m³,1.569 mm²/s Head Eff. 74.6% 73.9% 10 m 7800 5800 600 45.7% Efficiency Overall efficiency 73.6 % 66.7 % 7800 7800 5800 5800 600 600 Power input P1 Shaft power P2 7800 (P1) 7800 (P2) 5.93 kW 5800 (P1) 5800 (P2) 5.37 kW 600 600 (P1) (P2) NPSH-values 7800 5800 4.46 m 600 40.09 l/s 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 Nominal (mean) data shown. Under- and over-performance from this data should be expected due to standard manufacturing tolerances. Please consult your local Flygt representative for performance guarantees. Project Block Created by Created on Xylect-20810356 0 Program version Data version User group(s) 69.0 - 15/05/2023 (Build 33) 28/06/2023 10:31 Xylem: Dubai - EXT 75 Last update 7/5/2023 80 85 [l/s] Curve: ISO 9906 7/5/2023 Concertor N100-5800 Duty Analysis [m] Curves according to: Water, pure ,4 °C,1000 kg/m³,1.569 mm²/s 1 Head 26.0 25.0 24.0 23.0 22.0 21.0 20.0 19.0 18.0 17.0 16.0 15.0 14.0 13.0 12.0 11.0 73.9% 10 m 10.0 9.0 8.0 7.0 6.0 5.0 4.0 3.0 2.0 5800 1.0 40.09 l/s 0.0 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 [l/s] Operating characteristics Pumps / Systems Flow Head Shaft power Flow Head Shaft power Hydr.eff. Specific Energy NPSHre 1 40.1 l/s 10 m 5.37 kW 40.1 l/s 10 m 5.37 kW 73.6 % 0.0411 kWh/m³ 4.46 m Project Block Xylect-20810356 0 Created by Created on Program version Data version User group(s) 69.0 - 15/05/2023 (Build 33) 28/06/2023 10:31 Xylem: Dubai - EXT 7/5/2023 Last update 7/5/2023 Concertor N100-5800 Dimensional drawing 426 83 2" Guidebars 249 273 679 95 15 341 400 DN100 Min water level* 140 Z Z 70 23 979 701 213 192 71 100 200 Outlet center line 171 Ref. line 250 VIEW Z Z * Only applicable for intermittent duty. Consult the IOMfor more info. NP Project Block 6020 Created by Created on Xylect-20810356 0 Program version Data version User group(s) 69.0 - 15/05/2023 (Build 33) 28/06/2023 10:31 Xylem: Dubai - EXT MT 7/5/2023 Weight Pump Stand kg 117 43 Discharge outlet P ump outlet DN 100 DN 100 S cale 1:10 Date 220216 P ump inlet Drawing number Revision S uction inlet 8034100 3 Last update 7/5/2023