Uploaded by Rinson Jawer Rivera Gonzalez

SFTP CAT6 DOUBLE JACKET DATA SHEET (1)-1

advertisement
23AWG CAT6 SFTP CABLE
Part No.:
Cross Section
Performance
Electrical Characteristics:
Frequency
Attenuation
(MHz)
(dB/100m)
1
2.0
4
3.8
10
6.0
16
7.6
20
8.5
31.25
10.7
62.5
15.4
100
19.8
200
29
250
32.8
NEXT
(dB/100m)
74.3
65.3
59.3
56.2
54.8
51.9
47.4
44.3
39.8
38.3
PSNEXT
(dB/100m)
72.3
63.3
57.3
54.2
52.8
49.9
45.4
42.3
37.8
36.3
Return Loss
>=dB
20
23
25
25
25
24
22
20
18.0
17.3
Marking
TBD
Description
Application
Horizontal Wiring in LAN
Reference Standard
EIA/TIA568 & ISO/IEC 11801
Construction
Conductor
Solid Bare Copper
AWG
23
Conductor Dia. (mm)
0.57
Insulation
PE
Average Thickness(mm)
0.295
Insulation Dia.(±0.1mm)
1.16
Twisting Lay Length(mm)
30underneath
Cabling Lay Length(mm)
200underneath
Filler(CROSS)
PE
PET
YES
AL-PET
YES
Drain
CCS
Structure
1/0.50
Braid
AL&Mg
Structure
16/5/0.12
Coverage
>=45%
Inter Jacket
PVC
Average Thickness(mm)
0.55
Min. Point Thickness(mm)
0.46
Outer Dia.(±0.3mm)
8.10
Rip Cord
YES
Jacket
LLDPE
Average Thickness(mm)
0.5
Min. Point Thickness(mm)
0.45
Outer Dia.(±0.3mm)
9.20
Weight(kg/km)
------
Color
Insulation colors are:
Blue,White
Orange,White/Orange
Green,White/Green
Brown,White/Brown
Inter Jacket
Per customer request RAL7035
Jacket colors:
Per customer request (RAL9011)
Part No.:
Ref. spec No.:
Revision History
Frequency
(MHz)
1
4
10
16
20
31.25
62.5
100
200
250
ELFEXT
(dB/100m)
67.8
55.8
47.8
43.7
41.8
37.9
31.9
27.8
21.8
19.8
PSELFEXT
SRL.
(dB/100m)
(dB/100m)
64.8
52.8
44.8
40.7
>23
38.8
34.9
28.9
24.8
18.8
16.8
23-10Log(f/20)
1.0-250MHz Impedance (ohms)
1.0-250.0MHz Delay Skew (ns/100m)
Pair-to-Ground Capacitance Unbalance (pF/100m)
Max. Conductor DC Resistance 20oC (ohms/km)
Resistance Unbalance (%)
Delay
(ns/100m)
570.0
552.0
545.4
543.0
542.0
540.4
538.6
537.6
536.5
536.3
100 ± 15
<=45
<=330
93.8
<=5
Download