HP 3PAR StoreServ 70007450 Storage Cabling Configuration Guide E - 4 Node Systems with Large 3.5-inch Drive Enclosures-c03692692

advertisement
HP 3PAR StoreServ 7000/7450 Storage
Cabling Configuration Guide E:
4 Node Systems with Large 3.5-inch Drive
Enclosures
Abstract
This guide provides cabling information for authorized technicians performing installation and maintenance services on the HP
3PAR StoreServ 7000/7450 Storage systems.
HP Part Number: QR482-96649
Published: March 2014
© Copyright 2014 Hewlett-Packard Development Company, L.P.
The information contained herein is subject to change without notice. The only warranties for HP products and services are set forth in the express
warranty statements accompanying such products and services. Nothing herein should be construed as constituting an additional warranty. HP shall
not be liable for technical or editorial errors or omissions contained herein.
Acknowledgments
Microsoft®, Windows®, are U.S. registered trademarks of Microsoft Corporation.
Warranty
WARRANTY STATEMENT: To obtain a copy of the warranty for this product, see the warranty information website:
http://www.hp.com/go/storagewarranty
Printed in the US.
Contents
1 Cabling Preparation for HP 3PAR StoreServ 7000/7450.................................5
Following Precautions................................................................................................................5
Identifying and Labeling the Components....................................................................................5
2 Cabling HP 3PAR StoreServ 7000/7450.......................................................8
4 Node 2 Drive Enclosures (2L)..................................................................................................8
Attach DP-1 Chains to Enclosure.............................................................................................9
Attach DP-2 Chains to Enclosures.........................................................................................10
Review Completed Cabling.................................................................................................11
4 Node 4 Drive Enclosures (4L)................................................................................................12
Attach DP-1 Chains to Enclosures..........................................................................................13
Attach DP-2 Chains to Enclosures.........................................................................................14
Review Completed Cabling.................................................................................................15
4 Node 6 Drive Enclosures (6L)................................................................................................16
Attach DP-1 Chains to Enclosures..........................................................................................17
Attach DP-2 Chains to Enclosures.........................................................................................18
Review Completed Cabling.................................................................................................19
4 Node Interconnect Cabling..............................................................................................20
4 Node 8 Drive Enclosures (8L)................................................................................................21
Attach DP-1 Chains to Enclosures..........................................................................................22
Attach DP-2 Chains to Enclosures.........................................................................................23
Review Completed Cabling.................................................................................................24
4 Node Interconnect Cabling..............................................................................................25
4 Node 12 Drive Enclosures (12L)..............................................................................................26
Attach DP-1 Chains to Enclosures..........................................................................................27
Attach DP-2 Chains to Enclosures.........................................................................................28
Review Completed Cabling.................................................................................................29
4 Node Interconnect Cabling..............................................................................................30
4 Node 14 Drive Enclosures (14L)..............................................................................................31
Attach DP-1 Chains to Enclosures..........................................................................................32
Attach DP-2 Chains to Enclosures.........................................................................................33
Review Completed Cabling.................................................................................................34
4 Node Interconnect Cabling..............................................................................................35
4 Node 16 Drive Enclosures (16L).............................................................................................36
Attach DP-1 Chains to Enclosures..........................................................................................37
Attach DP-1 Chains to Enclosures Between Racks....................................................................38
Attach DP-2 Chains to Enclosures.........................................................................................39
Attach DP-2 Chains to Enclosures Between Racks....................................................................40
Review Completed Cabling.................................................................................................41
Review Completed Cabling Between Racks...........................................................................42
4 Node Interconnect Cabling..............................................................................................43
4 Node 18 Drive Enclosures (18L).............................................................................................44
Attach DP-1 Chains to Enclosures..........................................................................................45
Attach DP-1 Chains to Enclosures Between Racks....................................................................46
Attach DP-2 Chains to Enclosures.........................................................................................47
Attach DP-2 Chains to Enclosures Between Racks....................................................................48
Review Completed Cabling.................................................................................................49
Review Completed Cabling Between Racks...........................................................................50
4 Node Interconnect Cabling..............................................................................................51
3 Additional Resources and Related Documentation.........................................52
Contacting HP........................................................................................................................52
Contents
3
HP 3PAR Documentation..........................................................................................................52
4
Contents
1 Cabling Preparation for HP 3PAR StoreServ 7000/7450
The following instructions list important precautions and information about cabling installation
options for the storage system.
Following Precautions
Follow these general precautions to avoid injury, data loss, and damage before and during
installation or while servicing the HP 3PAR StoreServ Storage system:
•
Avoid using improper tools
•
Prepare an Electrostatic Discharge-safe (ESD) work surface by placing an antistatic mat on
the floor, or table, near the storage system. Attach the ground lead of the mat to an unpainted
surface of the rack
•
Always use a wrist-grounding strap, provided with the storage system. Attach the grounding
strap clip directly to an unpainted surface of the rack
•
Avoid contact between electronic components and clothing which can carry an electrostatic
charge
•
Ensure all cables are properly labeled and easily identifiable prior to removing a component
•
Observe local occupational safety requirements and guidelines for handling heavy equipment
•
Always load the heaviest item first, and start from the bottom when loading the rack. Loading
from the bottom makes the rack bottom-heavy and helps prevent the rack from becoming
unstable
•
Do not attempt to move a fully-loaded equipment rack. Remove all equipment from the rack
before moving the rack
•
Use at least two people to safely move the rack from the pallet
Identifying and Labeling the Components
This section of the chapter applies to all configurations in this guide. The guide provides instructional
guidance for cabling the HP 3PAR StoreServ 7000/7450 according to a specific configuration.
All HP 3PAR StoreServ Storage systems contain either the HP 3PAR 7200 (2 nodes) or 7400/7450
(with 2 or 4 nodes), M6720 large drive enclosure(s), and M6710 small drive enclosure(s).
The M6720 large drive enclosures supports 3.5-inch disk drives and the smaller M6710 drive
enclosure supports 2.5-inch disk drives.
The cabling configurations are identifiable by the specific number of nodes connecting to a
combination of small or large disk drive enclosures. The cabling configuration examples below
uses the following identification:
•
4 Node 1 Drive Enclosure (1S) refers to a configuration using four nodes connecting to one
small (2.5-inch) disk drive enclosure
•
4 Node 10 Drive Enclosures (6S+4L) refers to a configuration using four nodes connecting to
a combination of six small (2.5-inch) and four large (3.5-inch) drive enclosures
Following Precautions
5
Types of Components
Use the red and green color coding to assist with the cabling. Only connect to components sharing
the same color.
Figure 1 Identifying Components and SAS Ports
6
Cabling Preparation for HP 3PAR StoreServ 7000/7450
Labeling the Enclosures
Before connecting the cables:
•
Labels (A, B, C, and D) are provided to help identify the enclosures in the storage system.
Apply the labels to each enclosure in a visible location and avoid covering other labels
•
Apply label A to the controller enclosure with nodes 0 and 1. Alternate the labeling (A/B) on
each enclosure below the controller enclosure
If applicable, a system using four nodes, apply label C to the controller enclosure with nodes 2
and 3. Alternate the labeling (C/D) on each enclosure above the controller enclosure.
The illustration below describes a typical configuration using four nodes with a combination of
large and small drive enclosures.
NOTE: The illustrative depiction may not reflect the configuration setup of your system but the
labeling pattern is similar.
Figure 2 Labeling the Components
For more information relating to cabling hosts, refer to HP 3PAR StoreServ 7000/7450 Installation
Guide.
Identifying and Labeling the Components
7
2 Cabling HP 3PAR StoreServ 7000/7450
The following illustrative sections provide a rear view of the rack with recommended racking
configuration of the system.
4 Node 2 Drive Enclosures (2L)
Before you begin cabling the storage system, carefully read or print the following section, including
figures 1 and 2 “Identifying and Labeling the Components” (page 5).
8
Cabling HP 3PAR StoreServ 7000/7450
Attach DP-1 Chains to Enclosure
This system does not require any connections to node port DP-1.
4 Node 2 Drive Enclosures (2L)
9
Attach DP-2 Chains to Enclosures
Red routing
1.
2.
3.
4.
Connect
Connect
Connect
Connect
Node 0 (DP-2) to the I/O 0 (DP-1) on the B drive enclosure closest to the controller.
all B drive enclosures from (DP-2) to (DP-1) working away from the controller.
Node 2 (DP-2) to the I/O 0 (DP-1) on the D drive enclosure closest to the controller.
all D drive enclosures from (DP-2) to (DP-1) working away from the controller.
Green routing
1.
2.
3.
4.
Connect
Connect
Connect
Connect
NOTE:
10
Node 1 (DP-2) to I/O 1 (DP-1) on the B drive enclosure farthest from the controller.
all B drive enclosures from (DP-2) to (DP-1) working toward the controller.
Node 3 (DP-2) to I/O 1 (DP-1) on the D drive enclosure farthest from the controller.
all D drive enclosures from (DP-2) to (DP-1) working toward the controller.
The two adjacent enclosures are not directly connected.
Cabling HP 3PAR StoreServ 7000/7450
Review Completed Cabling
4 Node 2 Drive Enclosures (2L)
11
4 Node 4 Drive Enclosures (4L)
Before you begin cabling the storage system, carefully read or print the following section, including
figures 1 and 2 “Identifying and Labeling the Components” (page 5).
12
Cabling HP 3PAR StoreServ 7000/7450
Attach DP-1 Chains to Enclosures
Red routing
1.
2.
3.
4.
Connect
Connect
Connect
Connect
Node 0 (DP-1) to the I/O 0 (DP-1) on the A drive enclosure closest to the controller.
all A drive enclosures from (DP-2) to (DP-1) working away from the controller.
Node 2 (DP-1) to the I/O 0 (DP-1) on the C drive enclosure closest to the controller.
all C drive enclosures from (DP-2) to (DP-1) working away from the controller.
Green routing
1.
2.
3.
4.
Connect
Connect
Connect
Connect
NOTE:
Node 1 (DP-1) to I/O 1 (DP-1) on the A drive enclosure farthest from the controller.
all A drive enclosures from (DP-2) to (DP-1) working toward the controller.
Node 3 (DP-1) to I/O 1 (DP-1) on the C drive enclosure farthest from the controller.
all C drive enclosures from (DP-2) to (DP-1) working toward the controller.
The two adjacent enclosures are not directly connected.
4 Node 4 Drive Enclosures (4L)
13
Attach DP-2 Chains to Enclosures
Red routing
1.
2.
3.
4.
Connect
Connect
Connect
Connect
Node 0 (DP-2) to the I/O 0 (DP-1) on the B drive enclosure closest to the controller.
all B drive enclosures from (DP-2) to (DP-1) working away from the controller.
Node 2 (DP-2) to the I/O 0 (DP-1) on the D drive enclosure closest to the controller.
all D drive enclosures from (DP-2) to (DP-1) working away from the controller.
Green routing
1.
2.
3.
4.
Connect
Connect
Connect
Connect
NOTE:
14
Node 1 (DP-2) to I/O 1 (DP-1) on the B drive enclosure farthest from the controller.
all B drive enclosures from (DP-2) to (DP-1) working toward the controller.
Node 3 (DP-2) to I/O 1 (DP-1) on the D drive enclosure farthest from the controller.
all D drive enclosures from (DP-2) to (DP-1) working toward the controller.
The two adjacent enclosures are not directly connected.
Cabling HP 3PAR StoreServ 7000/7450
Review Completed Cabling
4 Node 4 Drive Enclosures (4L)
15
4 Node 6 Drive Enclosures (6L)
Before you begin cabling the storage system, carefully read or print the following section, including
figures 1 and 2 “Identifying and Labeling the Components” (page 5).
16
Cabling HP 3PAR StoreServ 7000/7450
Attach DP-1 Chains to Enclosures
Red routing
1.
2.
3.
4.
Connect
Connect
Connect
Connect
Node 0 (DP-1) to the I/O 0 (DP-1) on the A drive enclosure closest to the controller.
all A drive enclosures from (DP-2) to (DP-1) working away from the controller.
Node 2 (DP-1) to the I/O 0 (DP-1) on the C drive enclosure closest to the controller.
all C drive enclosures from (DP-2) to (DP-1) working away from the controller.
Green routing
1.
2.
3.
4.
Connect
Connect
Connect
Connect
NOTE:
Node 1 (DP-1) to I/O 1 (DP-1) on the A drive enclosure farthest from the controller.
all A drive enclosures from (DP-2) to (DP-1) working toward the controller.
Node 3 (DP-1) to I/O 1 (DP-1) on the C drive enclosure farthest from the controller.
all C drive enclosures from (DP-2) to (DP-1) working toward the controller.
The two adjacent enclosures are not directly connected.
4 Node 6 Drive Enclosures (6L)
17
Attach DP-2 Chains to Enclosures
Red routing
1.
2.
3.
4.
Connect
Connect
Connect
Connect
Node 0 (DP-2) to the I/O 0 (DP-1) on the B drive enclosure closest to the controller.
all B drive enclosures from (DP-2) to (DP-1) working away from the controller.
Node 2 (DP-2) to the I/O 0 (DP-1) on the D drive enclosure closest to the controller.
all D drive enclosures from (DP-2) to (DP-1) working away from the controller.
Green routing
1.
2.
3.
4.
Connect
Connect
Connect
Connect
NOTE:
Node 1 (DP-2) to I/O 1 (DP-1) on the B drive enclosure farthest from the controller.
all B drive enclosures from (DP-2) to (DP-1) working toward the controller.
Node 3 (DP-2) to I/O 1 (DP-1) on the D drive enclosure farthest from the controller.
all D drive enclosures from (DP-2) to (DP-1) working toward the controller.
The two adjacent enclosures are not directly connected.
CAUTION
Disconnect all power
for complete isolation
DP-1
DP-2
3
1
DP-1
DP-2
1
Disconnect all power
for complete isolation
CAUTION
D
3
CAUTION
Disconnect all power
for complete isolation
Disconnect all power
for complete isolation
CAUTION
CAUTION
Disconnect all power
for complete isolation
3
3
1
1
Disconnect all power
for complete isolation
CAUTION
CAUTION
Disconnect all power
for complete isolation
Disconnect all power
for complete isolation
CAUTION
CAUTION
Disconnect all power
for complete isolation
DP-1
DP-2
3
1
DP-1
DP-2
1
Disconnect all power
for complete isolation
CAUTION
D
3
CAUTION
Disconnect all power
for complete isolation
Disconnect all power
for complete isolation
CAUTION
C
DP-2
DP-1
DP-1
DP-2
A
DP-2
DP-1
DP-1
DP-2
CAUTION
Disconnect all power
for complete isolation
3
DP-2
DP-1
DP-2
3
Disconnect all power
for complete isolation
CAUTION
B
DP-1
CAUTION
1
1
Disconnect all power
for complete isolation
Disconnect all power
for complete isolation
CAUTION
CAUTION
Disconnect all power
for complete isolation
3
3
1
1
Disconnect all power
for complete isolation
CAUTION
CAUTION
Disconnect all power
for complete isolation
Disconnect all power
for complete isolation
CAUTION
CAUTION
Disconnect all power
for complete isolation
DP-1
DP-2
3
1
DP-1
DP-2
1
Disconnect all power
for complete isolation
CAUTION
B
3
CAUTION
Disconnect all power
for complete isolation
Disconnect all power
for complete isolation
CAUTION
18
Cabling HP 3PAR StoreServ 7000/7450
Review Completed Cabling
4 Node 6 Drive Enclosures (6L)
19
4 Node Interconnect Cabling
The interconnection between Controller A (node pair 0/1), and Controller B (node pair 2/3) uses
the four large interconnect cables.
The cables are DIRECTIONAL and must be installed correctly for the system to function properly.
Connect one cable at a time:
1. Controller A, Node 0, Intr 0 to Controller C, Node 2, Intr 1
2. Controller A, Node 0, Intr 1 to Controller C, Node 3, Intr 0
3. Controller A, Node 1, Intr 0 to Controller C, Node 3, Intr 1
4. Controller A, Node 1, Intr 1 to Controller C, Node 2, Intr 0
The completed cabling is shown below.
After confirming all cabling is correct (SAS and interconnection), the system may be powered on
by using procedures from the installation guide.
NOTE:
20
The Interconnect Link Cables are directional and labeled A and C.
Cabling HP 3PAR StoreServ 7000/7450
4 Node 8 Drive Enclosures (8L)
Before you begin cabling the storage system, carefully read or print the following section, including
figures 1 and 2 “Identifying and Labeling the Components” (page 5).
4 Node 8 Drive Enclosures (8L)
21
Attach DP-1 Chains to Enclosures
Red routing
1.
2.
3.
4.
Connect
Connect
Connect
Connect
Node 0 (DP-1) to the I/O 0 (DP-1) on the A drive enclosure closest to the controller.
all A drive enclosures from (DP-2) to (DP-1) working away from the controller.
Node 2 (DP-1) to the I/O 0 (DP-1) on the C drive enclosure closest to the controller.
all C drive enclosures from (DP-2) to (DP-1) working away from the controller.
Green routing
1.
2.
3.
4.
Connect
Connect
Connect
Connect
NOTE:
22
Node 1 (DP-1) to I/O 1 (DP-1) on the A drive enclosure farthest from the controller.
all A drive enclosures from (DP-2) to (DP-1) working toward the controller.
Node 3 (DP-1) to I/O 1 (DP-1) on the C drive enclosure farthest from the controller.
all C drive enclosures from (DP-2) to (DP-1) working toward the controller.
The two adjacent enclosures are not directly connected.
Cabling HP 3PAR StoreServ 7000/7450
Attach DP-2 Chains to Enclosures
Red routing
1.
2.
3.
4.
Connect
Connect
Connect
Connect
Node 0 (DP-2) to the I/O 0 (DP-1) on the B drive enclosure closest to the controller.
all B drive enclosures from (DP-2) to (DP-1) working away from the controller.
Node 2 (DP-2) to the I/O 0 (DP-1) on the D drive enclosure closest to the controller.
all D drive enclosures from (DP-2) to (DP-1) working away from the controller.
Green routing
1.
2.
3.
4.
Connect
Connect
Connect
Connect
NOTE:
Node 1 (DP-2) to I/O 1 (DP-1) on the B drive enclosure farthest from the controller.
all B drive enclosures from (DP-2) to (DP-1) working toward the controller.
Node 3 (DP-2) to I/O 1 (DP-1) on the D drive enclosure farthest from the controller.
all D drive enclosures from (DP-2) to (DP-1) working toward the controller.
The two adjacent enclosures are not directly connected.
4 Node 8 Drive Enclosures (8L)
23
Review Completed Cabling
24
Cabling HP 3PAR StoreServ 7000/7450
4 Node Interconnect Cabling
The interconnection between Controller A (node pair 0/1), and Controller B (node pair 2/3) uses
the four large interconnect cables.
The cables are DIRECTIONAL and must be installed correctly for the system to function properly.
Connect one cable at a time:
1. Controller A, Node 0, Intr 0 to Controller C, Node 2, Intr 1
2. Controller A, Node 0, Intr 1 to Controller C, Node 3, Intr 0
3. Controller A, Node 1, Intr 0 to Controller C, Node 3, Intr 1
4. Controller A, Node 1, Intr 1 to Controller C, Node 2, Intr 0
The completed cabling is shown below.
After confirming all cabling is correct (SAS and interconnection), the system may be powered on
by using procedures from the installation guide.
CAUTION:
The Interconnect Link Cables are directional and labeled A and C.
4 Node 8 Drive Enclosures (8L)
25
4 Node 12 Drive Enclosures (12L)
Before you begin cabling the storage system, carefully read or print the following section, including
figures 1 and 2 “Identifying and Labeling the Components” (page 5).
26
Cabling HP 3PAR StoreServ 7000/7450
Attach DP-1 Chains to Enclosures
Red routing
1.
2.
Connect Node 2 (DP-1) to the I/O 0 (DP-1) on the C drive enclosure closest to the controller.
Connect all C drive enclosures from (DP-2) to (DP-1) working away from the controller.
Green routing
1.
2.
Connect Node 3 (DP-1) to I/O 1 (DP-1) on the C drive enclosure farthest from the controller.
Connect all C drive enclosures from (DP-2) to (DP-1) working toward the controller.
NOTE:
The two adjacent enclosures are not directly connected.
4 Node 12 Drive Enclosures (12L)
27
Attach DP-2 Chains to Enclosures
Red routing
1.
2.
Connect Node 2 (DP-2) to the I/O 0 (DP-1) on the D drive enclosure closest to the controller.
Connect all D drive enclosures from (DP-2) to (DP-1) working away from the controller.
Green routing
1.
2.
Connect Node 3 (DP-2) to I/O 1 (DP-1) on the D drive enclosure farthest from the controller.
Connect all D drive enclosures from (DP-2) to (DP-1) working toward the controller.
NOTE:
28
The two adjacent enclosures are not directly connected.
Cabling HP 3PAR StoreServ 7000/7450
Review Completed Cabling
4 Node 12 Drive Enclosures (12L)
29
4 Node Interconnect Cabling
The interconnection between Controller A (node pair 0/1), and Controller B (node pair 2/3) uses
the four large interconnect cables.
The cables are DIRECTIONAL and must be installed correctly for the system to function properly.
Connect one cable at a time:
1. Controller A, Node 0, Intr 0 to Controller C, Node 2, Intr 1
2. Controller A, Node 0, Intr 1 to Controller C, Node 3, Intr 0
3. Controller A, Node 1, Intr 0 to Controller C, Node 3, Intr 1
4. Controller A, Node 1, Intr 1 to Controller C, Node 2, Intr 0
The completed cabling is shown below.
After confirming all cabling is correct (SAS and interconnection), the system may be powered on
by using procedures from the installation guide.
CAUTION:
30
The Interconnect Link Cables are directional and labeled A and C.
Cabling HP 3PAR StoreServ 7000/7450
4 Node 14 Drive Enclosures (14L)
Before you begin cabling the storage system, carefully read or print the following section, including
figures 1 and 2 “Identifying and Labeling the Components” (page 5).
4 Node 14 Drive Enclosures (14L)
31
Attach DP-1 Chains to Enclosures
Red routing
1.
2.
Connect Node 2 (DP-1) to the I/O 0 (DP-1) on the C drive enclosure closest to the controller.
Connect all C drive enclosures from (DP-2) to (DP-1) working away from the controller.
Green routing
1.
2.
Connect Node 3 (DP-1) to I/O 1 (DP-1) on the C drive enclosure farthest from the controller.
Connect all C drive enclosures from (DP-2) to (DP-1) working toward the controller.
NOTE:
32
The two adjacent enclosures are not directly connected.
Cabling HP 3PAR StoreServ 7000/7450
Attach DP-2 Chains to Enclosures
Red routing
1.
2.
Connect Node 2 (DP-2) to the I/O 0 (DP-1) on the D drive enclosure closest to the controller.
Connect all D drive enclosures from (DP-2) to (DP-1) working away from the controller.
Green routing
1.
2.
Connect Node 3 (DP-2) to I/O 1 (DP-1) on the D drive enclosure farthest from the controller.
Connect all D drive enclosures from (DP-2) to (DP-1) working toward the controller.
NOTE:
The two adjacent enclosures are not directly connected.
4 Node 14 Drive Enclosures (14L)
33
Review Completed Cabling
34
Cabling HP 3PAR StoreServ 7000/7450
4 Node Interconnect Cabling
The interconnection between Controller A (node pair 0/1), and Controller B (node pair 2/3) uses
the four large interconnect cables.
The cables are DIRECTIONAL and must be installed correctly for the system to function properly.
Connect one cable at a time:
1. Controller A, Node 0, Intr 0 to Controller C, Node 2, Intr 1
2. Controller A, Node 0, Intr 1 to Controller C, Node 3, Intr 0
3. Controller A, Node 1, Intr 0 to Controller C, Node 3, Intr 1
4. Controller A, Node 1, Intr 1 to Controller C, Node 2, Intr 0
The completed cabling is shown below.
After confirming all cabling is correct (SAS and interconnection), the system may be powered on
by using procedures from the installation guide.
CAUTION:
The Interlink Cables are directional and labeled A and C.
4 Node 14 Drive Enclosures (14L)
35
4 Node 16 Drive Enclosures (16L)
Before you begin cabling the storage system, carefully read or print the following section, including
figures 1 and 2 “Identifying and Labeling the Components” (page 5).
36
Cabling HP 3PAR StoreServ 7000/7450
Attach DP-1 Chains to Enclosures
Red routing
1.
2.
Connect Node 2 (DP-1) to the I/O 0 (DP-1) on the C drive enclosure closest to the controller.
Connect all C drive enclosures from (DP-2) to (DP-1) working away from the controller.
Green routing
1.
2.
Connect Node 3 (DP-1) to I/O 1 (DP-1) on the C drive enclosure farthest from the controller.
Connect all C drive enclosures from (DP-2) to (DP-1) working toward the controller.
NOTE:
The two adjacent enclosures are not directly connected.
4 Node 16 Drive Enclosures (16L)
37
Attach DP-1 Chains to Enclosures Between Racks
Six meter (6m) cables must be used for connections between racks.
Red routing
1.
2.
Connect Node 0 (DP-1) to the I/O 0 (DP-1) on the A drive enclosure closest to the controller.
Connect all A drive enclosures from (DP-2) to (DP-1) working away from the controller.
Green routing
1.
2.
Connect Node 1 (DP-1) to I/O 1 (DP-1) on the A drive enclosure farthest from the controller.
Connect all A drive enclosures from (DP-2) to (DP-1) working toward the controller.
NOTE:
38
The two adjacent enclosures are not directly connected.
Cabling HP 3PAR StoreServ 7000/7450
Attach DP-2 Chains to Enclosures
Red routing
1.
2.
Connect Node 2 (DP-2) to the I/O 0 (DP-1) on the D drive enclosure closest to the controller.
Connect all D drive enclosures from (DP-2) to (DP-1) working away from the controller.
Green routing
1.
2.
Connect Node 3 (DP-2) to I/O 1 (DP-1) on the D drive enclosure farthest from the controller.
Connect all D drive enclosures from (DP-2) to (DP-1) working toward the controller.
NOTE:
The two adjacent enclosures are not directly connected.
4 Node 16 Drive Enclosures (16L)
39
Attach DP-2 Chains to Enclosures Between Racks
Six meter (6m) cables must be used for connections between racks.
Red routing
1.
2.
Connect Node 0 (DP-2) to the I/O 0 (DP-1) on the B drive enclosure closest to the controller.
Connect all B drive enclosures from (DP-2) to (DP-1) working away from the controller.
Green routing
1.
2.
Connect Node 1 (DP-2) to I/O 1 (DP-1) on the B drive enclosure farthest from the controller.
Connect all B drive enclosures from (DP-2) to (DP-1) working toward the controller.
NOTE:
40
The two adjacent enclosures are not directly connected.
Cabling HP 3PAR StoreServ 7000/7450
Review Completed Cabling
4 Node 16 Drive Enclosures (16L)
41
Review Completed Cabling Between Racks
42
Cabling HP 3PAR StoreServ 7000/7450
4 Node Interconnect Cabling
The interconnection between Controller A (node pair 0/1), and Controller B (node pair 2/3) uses
the four large interconnect cables.
The cables are DIRECTIONAL and must be installed correctly for the system to function properly.
Connect one cable at a time:
1. Controller A, Node 0, Intr 0 to Controller C, Node 2, Intr 1
2. Controller A, Node 0, Intr 1 to Controller C, Node 3, Intr 0
3. Controller A, Node 1, Intr 0 to Controller C, Node 3, Intr 1
4. Controller A, Node 1, Intr 1 to Controller C, Node 2, Intr 0
The completed cabling is shown below.
After confirming all cabling is correct (SAS and interconnection), the system may be powered on
by using procedures from the installation guide.
CAUTION:
The Interconnect Link Cables are directional and labeled A and C.
4 Node 16 Drive Enclosures (16L)
43
4 Node 18 Drive Enclosures (18L)
Before you begin cabling the storage system, carefully read or print the following section, including
figures 1 and 2 “Identifying and Labeling the Components” (page 5).
44
Cabling HP 3PAR StoreServ 7000/7450
Attach DP-1 Chains to Enclosures
Red routing
1.
2.
Connect Node 2 (DP-1) to the I/O 0 (DP-1) on the C drive enclosure closest to the controller.
Connect all C drive enclosures from (DP-2) to (DP-1) working away from the controller.
Green routing
1.
2.
Connect Node 3 (DP-1) to I/O 1 (DP-1) on the C drive enclosure farthest from the controller.
Connect all C drive enclosures from (DP-2) to (DP-1) working toward the controller.
NOTE:
The two adjacent enclosures are not directly connected.
4 Node 18 Drive Enclosures (18L)
45
Attach DP-1 Chains to Enclosures Between Racks
Six meter (6m) cables must be used for connections between racks.
Red routing
1.
2.
Connect Node 0 (DP-1) to the I/O 0 (DP-1) on the A drive enclosure closest to the controller.
Connect all A drive enclosures from (DP-2) to (DP-1) working away from the controller.
Green routing
1.
2.
Connect Node 1 (DP-1) to I/O 1 (DP-1) on the A drive enclosure farthest from the controller.
Connect all A drive enclosures from (DP-2) to (DP-1) working toward the controller.
NOTE:
46
The two adjacent enclosures are not directly connected.
Cabling HP 3PAR StoreServ 7000/7450
Attach DP-2 Chains to Enclosures
Red routing
1.
2.
Connect Node 2 (DP-2) to the I/O 0 (DP-1) on the D drive enclosure closest to the controller.
Connect all D drive enclosures from (DP-2) to (DP-1) working away from the controller.
Green routing
1.
2.
Connect Node 3 (DP-2) to I/O 1 (DP-1) on the D drive enclosure farthest from the controller.
Connect all D drive enclosures from (DP-2) to (DP-1) working toward the controller.
NOTE:
The two adjacent enclosures are not directly connected.
4 Node 18 Drive Enclosures (18L)
47
Attach DP-2 Chains to Enclosures Between Racks
Six meter (6m) cables must be used for connections between racks.
Red routing
1.
2.
Connect Node 0 (DP-2) to the I/O 0 (DP-1) on the B drive enclosure closest to the controller.
Connect all B drive enclosures from (DP-2) to (DP-1) working away from the controller.
Green routing
1.
2.
Connect Node 1 (DP-2) to I/O 1 (DP-1) on the B drive enclosure farthest from the controller.
Connect all B drive enclosures from (DP-2) to (DP-1) working toward the controller.
NOTE:
48
The two adjacent enclosures are not directly connected.
Cabling HP 3PAR StoreServ 7000/7450
Review Completed Cabling
4 Node 18 Drive Enclosures (18L)
49
Review Completed Cabling Between Racks
50
Cabling HP 3PAR StoreServ 7000/7450
4 Node Interconnect Cabling
The interconnection between Controller A (node pair 0/1), and Controller B (node pair 2/3) uses
the four large interconnect cables.
The cables are DIRECTIONAL and must be installed correctly for the system to function properly.
Connect one cable at a time:
1. Controller A, Node 0, Intr 0 to Controller C, Node 2, Intr 1
2. Controller A, Node 0, Intr 1 to Controller C, Node 3, Intr 0
3. Controller A, Node 1, Intr 0 to Controller C, Node 3, Intr 1
4. Controller A, Node 1, Intr 1 to Controller C, Node 2, Intr 0
The completed cabling is shown below.
After confirming all cabling is correct (SAS and interconnection), the system may be powered on
by using procedures from the installation guide.
CAUTION:
The Interconnect Link Cables are directional and labeled A and C.
4 Node 18 Drive Enclosures (18L)
51
3 Additional Resources and Related Documentation
Contacting HP
For worldwide technical support information, see the HP support website:
http://www.hp.com/support
Before contacting HP, collect the following information:
•
Product model names and numbers
•
Technical support registration number (if applicable)
•
Product serial numbers
•
Error messages
•
Operating system type and revision level
•
Detailed questions
Specify the type of support you are requesting:
HP 3PAR Storage System
Support Request
HP 3PAR StoreServ 7200, 7400, and 7450 Storage
systems
StoreServ 7000/7450 Storage
HP 3PAR StoreServ 10000 Storage systems
3PAR or 3PAR Storage
HP 3PAR T-Class storage systems
HP 3PAR F-Class storage systems
HP 3PAR Documentation
For additional information about other related cabling configurations, refer to the following
documents:
52
•
HP 3PAR StoreServ 7000/7450 Storage Cabling Configuration Guide A: 2 Node Systems
with Small 2.5-inch Drive Enclosures
•
HP 3PAR StoreServ 7000/7450 Storage Cabling Configuration Guide B: 2 Node Systems
with Large 3.5-inch Drive Enclosures
•
HP 3PAR StoreServ 7000/7450 Storage Cabling Configuration Guide C: 2 Node Systems
with Mixed-Size Drive Enclosures
•
HP 3PAR StoreServ 7000/7450 Storage Cabling Configuration Guide D: 4 Node Systems
with Small 2.5-inch Drive Enclosures
•
HP 3PAR StoreServ 7000/7450 Storage Cabling Configuration Guide E: 4 Node Systems
with Large 3.5-inch Drive Enclosures
•
HP 3PAR StoreServ 7000/7450 Storage Cabling Configuration Guide F: 4 Node Systems
with Mixed-Size Drive Enclosures
Additional Resources and Related Documentation