Uploaded by mengk.lin

80xxGEM SECS(x-xx-x-473 version) Release

advertisement
Kulicke & Soffa
SECS/GEM Interface for
K&S Model Power Series Automatic Ball Bonder,
K&S Model Gen-S Automatic Ball Bonder,
Running 8-88-4-73
The information in this document is the property of Kulicke & Soffa. Any reproduction or distribution to a
third party is strictly forbidden unless written permission is given by an authorized agent of Kulicke & Soffa.
Kulicke & Soffa Pte Ltd
23A Serangoon North Ave 5 #01-01
K&S Corporate Headquarters
Singapore 554369
Phone: +65-6880-9600
Fax:
+65-6880-9580
Document Revision 4.2
Jan 28, 2021
SECS/GEM Interface for Ball Bonders
Bonder software version x-xx-x-473-series
Table of Contents
1. GENERAL INFORMATION .................................................................. - 10 1.1
1.2
1.3
INTRODUCTION ................................................................................................................................... - 10 MANUFACTURER AND PRODUCT MODEL ............................................................................................ - 10 GENERAL DESCRIPTION OF EQUIPMENT FUNCTION ............................................................................ - 10 Intended Function of Interface ................................................................................................ - 10 Software Version Number ....................................................................................................... - 10 -
2. SECS-II MESSAGE SUMMARY .......................................................... - 14 2.1
2.2
HOST-ORIGINATED T RANSACTIONS ................................................................................................... - 14 EQUIPMENT-ORIGINATED T RANSACTIONS .......................................................................................... - 16 -
3. SECS-II MESSAGE DETAIL ................................................................ - 17 3.1
3.2
DATA ITEMS ....................................................................................................................................... - 17 Data Dictionary........................................................................................................................ - 17 Status Variables ....................................................................................................................... - 26 Equipment Constants .............................................................................................................. - 26 Collection Events ..................................................................................................................... - 26 Alarms...................................................................................................................................... - 26 HOST-ORIGINATED T RANSACTIONS ................................................................................................... - 26 Sx,F0 Abort Transaction (SxF0).............................................................................................. - 26 S1,F1 Are You There Request (R) ........................................................................................... - 26 S1,F2 On Line Data (D) ........................................................................................................... - 26 S1,F3 Selected Equipment Status Request (SSR) .................................................................... - 26 S1,F4 Selected Equipment Status Data (SSD) ......................................................................... - 27 S1,F11 Status Variable Namelist Request (SVNR) ................................................................. - 27 S1,F12 Status Variable Namelist Reply (SVNRR) .................................................................. - 27 S1,F13 Establish Communications Request (CR) ................................................................... - 27 S1,F14 Establish Communications Request Acknowledge (CRA) .......................................... - 28 S1,F15 Request OFF-LINE (ROFL) ....................................................................................... - 28 S1,F16 OFF-LINE Acknowledge (OFLA) ............................................................................... - 28 S1,F17 Request ON-LINE (RONL) ......................................................................................... - 28 S1,F18 ON-LINE Acknowledge (ONLA) ................................................................................ - 28 S2,F13 Equipment Constant Request (ECR) .......................................................................... - 28 S2,F14 Equipment Constant Data (ECD)................................................................................ - 28 S2,F15 New Equipment Constant Send (ECS) ........................................................................ - 28 S2,F16 New Equipment Constant Acknowledge (ECA).......................................................... - 29 S2,F17 Date and Time Request (DTR) .................................................................................... - 29 S2,F18 Date and Time Data (DTD) ......................................................................................... - 29 S2,F23 Trace Initialize Send (TIS) .......................................................................................... - 29 S2,F24 Trace Initialize Acknowledge (TIA) ............................................................................ - 29 S2,F29 Equipment Constant Namelist (ECNR) ...................................................................... - 30 S2,F30 Equipment Constant Namelist (ECN) ......................................................................... - 30 S2,F31 Date and Time Set Request (DTS) ............................................................................... - 30 S2,F32 Date and Time Set Acknowledge (DTA) ..................................................................... - 30 S2,F33 Define Report (DR) ...................................................................................................... - 30 S2,F34 Define Report Acknowledge (DRA) ............................................................................ - 31 S2,F35 Link Event Report (LER) ............................................................................................ - 32 S2,F36 Link Event Report Acknowledge (LERA) .................................................................. - 32 S2,F37 Enable/Disable Event Report (EDER) ........................................................................ - 33 S2,F38 Enable/Disable Event Report Acknowledge (EERA) .................................................. - 33 S2,F39 Multi-Block Inquire (MBI) .......................................................................................... - 33 S2,F40 Multi-Block Grant (MBG)........................................................................................... - 33 Page ii of 324
Jan 28, 2021 Rev 4.2
Kulicke & Soffa™
SECS/GEM Interface for Ball Bonders
Bonder software version x-xx-x-473-series
Table of Contents
3.3
S2,F41 Host Command Send (HCS) ........................................................................................ - 33 S2,F42 Host Command Acknowledge (HCA) ......................................................................... - 34 S2,F43 Reset Spooling Streams and Functions (RSSF) ........................................................... - 34 S2,F44 Reset Spooling Acknowledge (RSA) ............................................................................ - 35 S2,F45 Define Variable Limit Attributes (DVLA) .................................................................. - 35 S2,F46 Variable Limit Attribute Acknowledge (VLAA)......................................................... - 36 S2,F47 Variable Limit Attribute Request (VLAR) ................................................................. - 37 S2,F48 Variable Limit Attributes Send (VLAS) ..................................................................... - 37 S5,F3 Enable/Disable Alarm Send (EAS) ................................................................................ - 38 S5,F4 Enable/Disable Alarm Acknowledge (EAA) ................................................................. - 38 S5,F5 List Alarms Request (LAR) ........................................................................................... - 38 S5,F6 List Alarms Data (LAD) ................................................................................................ - 39 S6,F15 Event Report Request (ERR) ...................................................................................... - 39 S6,F16 Event Report Data (ERD)............................................................................................ - 40 S6,F19 Individual Report Request (IRR) ................................................................................ - 40 S6,F20 Individual Report Data (IRD) ..................................................................................... - 40 S6,F23 Request Spooled Data (RSD) ....................................................................................... - 40 S6,F24 Request Spooled Data Acknowledgment Send (RSDAS) ............................................ - 40 S7,F1 Process Program Load Inquire (PPI) ............................................................................ - 41 S7,F2 Process Program Load Grant (PPG)............................................................................. - 41 S7,F3 Process Program Send (PPS) ......................................................................................... - 41 S7,F4 Process Program Acknowledge (PPA) .......................................................................... - 41 S7,F5 Process Program Request (PPR) ................................................................................... - 41 S7,F6 Process Program Data (PPD) ........................................................................................ - 41 S7,F17 Delete Process Program Send (DPS) ........................................................................... - 41 S7,F18 Delete Process Program Acknowledge (DPA) ............................................................. - 42 S7,F19 Current EPPD Request (RER) .................................................................................... - 42 S7,F20 Current EPPD Data (RED) ......................................................................................... - 42 S10,F3 Terminal Display, Single (VTN) .................................................................................. - 42 S10,F4 Terminal Display, Single Acknowledge (VTA) ........................................................... - 42 S10,F5 Terminal Display, Multi-Block(VTM) ........................................................................ - 42 S10,F6 Terminal Display, Multi-Block Acknowledge (VMA) ................................................. - 43 S13,F1 Send Data Set Send (DSSS) ......................................................................................... - 43 S13,F2 Send Data Set Acknowledge (DSSA) ........................................................................... - 43 EQUIPMENT-ORIGINATED T RANSACTIONS .......................................................................................... - 44 Sx,F0 Abort Transaction (SxF0).............................................................................................. - 44 S1,F1 Are You There Request (R) ........................................................................................... - 44 S1,F2 On Line Data (D) ........................................................................................................... - 44 S1,F13 Establish Communications Request (CR) ................................................................... - 44 S1,F14 Establish Communications Request Acknowledge (CRA) .......................................... - 44 S5,F1 Alarm Report Send (ARS)............................................................................................. - 44 S5,F2 Alarm Report Acknowledge (ARA) .............................................................................. - 44 S6,F1 Trace Data Send ............................................................................................................ - 45 S6,F2 Trace Data Acknowledge............................................................................................... - 45 S6,F5 Multi-block Data Send Inquire (MBI) .......................................................................... - 45 S6,F6 Multi-block Grant (MBG) ............................................................................................. - 45 S6,F11 Event Report Send (ERS) ............................................................................................ - 45 S6,F12 Event Report Acknowledge (ERA) .............................................................................. - 46 S7,F1 Process Program Load Inquire (PPI) ............................................................................ - 46 S7,F2 Process Program Load Grant (PPG)............................................................................. - 46 S7,F3 Process Program Send (PPS) ......................................................................................... - 46 Page iii of 324
Jan 28, 2021 Rev 4.2
Kulicke & Soffa™
SECS/GEM Interface for Ball Bonders
Bonder software version x-xx-x-473-series
Table of Contents
S7,F4 Process Program Acknowledge (PPA) .......................................................................... - 46 S7,F5 Process Program Request (PPR) ................................................................................... - 47 S7,F6 Process Program Data (PPD) ........................................................................................ - 47 S9,F1 Unrecognized Device ID (UDN)..................................................................................... - 47 S9,F3 Unrecognized Stream Type (USN) ................................................................................ - 47 S9,F5 Unrecognized Function Type (UFN) ............................................................................. - 48 S9,F7 Illegal Data (IDN) .......................................................................................................... - 48 S9,F9 Transaction Timer Timeout (TTN) ............................................................................... - 48 S9,F11 Data Too Long (DLN) .................................................................................................. - 48 S10, F1 Terminal Request (TRN) ............................................................................................ - 48 S10, F2 Terminal Request Acknowledge (TRA) ..................................................................... - 48 S13,F3 Open Data Set Request (DSOR) .................................................................................. - 48 S13,F4 Open Data Set Data (DSOD) ....................................................................................... - 48 S13,F5 Read Data Set Request (DSRR) ................................................................................... - 49 S13,F6 Read Data Set Data (DSRD) ........................................................................................ - 49 S13,F7 Close Data Set Send (DSCS) ........................................................................................ - 49 S13,F8 Close Data Set Acknowledge (DSCA).......................................................................... - 49 S14,F1 GetAttr Request(GAR) ................................................................................................ - 49 S14,F2 GetAttr Data (GAD) .................................................................................................... - 50 -
4. STATE MODELS, CAPABILITIES, AND SCENARIOS ................... - 51 4.1
4.2
4.3
4.4
4.5
COMMUNICATIONS .............................................................................................................................. - 51 Communications State Model.................................................................................................. - 51 Communications State Transitions ......................................................................................... - 53 Host Attempts to Establish Communications.......................................................................... - 54 Host-Initiated Are You There ................................................................................................. - 54 Equipment-Initiated Are You There ....................................................................................... - 54 CONTROL ........................................................................................................................................... - 55 Control State Model................................................................................................................. - 55 Control State Transitions ........................................................................................................ - 56 Host Accepts ON-LINE ........................................................................................................... - 56 Host Denies ON-LINE ............................................................................................................. - 57 Operator Sets OFF-LINE ........................................................................................................ - 57 Operator Sets REMOTE ......................................................................................................... - 57 Operator Sets LOCAL............................................................................................................. - 57 Host Sets OFF-LINE ............................................................................................................... - 57 Host Sets ON-LINE ................................................................................................................. - 58 PROCESS ........................................................................................................................................... - 58 Process State Model ................................................................................................................. - 58 Process State Transitions ......................................................................................................... - 59 Process States........................................................................................................................... - 59 DATA COLLECTION ............................................................................................................................. - 60 Event Data Collection .............................................................................................................. - 60 Host Requests Collection Event Report .................................................................................. - 60 Collection Event Reporting Setup ........................................................................................... - 60 Host Requests Report .............................................................................................................. - 60 Equipment Status Report ........................................................................................................ - 61 Equipment Status Variable Namelist Report .......................................................................... - 61 ALARMS ............................................................................................................................................. - 61 Enable/Disable Alarms ............................................................................................................ - 61 Upload Alarm Information...................................................................................................... - 61 Page iv of 324
Jan 28, 2021 Rev 4.2
Kulicke & Soffa™
SECS/GEM Interface for Ball Bonders
Bonder software version x-xx-x-473-series
Table of Contents
4.6
4.7
4.8
4.9
4.10
4.11
4.12
4.13
4.14
4.15
4.16
Alarm Detected By Equipment................................................................................................ - 61 REMOTE CONTROL ............................................................................................................................. - 61 Host Sends Remote Command to Equipment ......................................................................... - 61 EQUIPMENT CONSTANTS .................................................................................................................... - 71 Host Sends Equipment Constants ........................................................................................... - 71 Host Equipment Constants Request ........................................................................................ - 71 Host Equipment Constants Namelist Request......................................................................... - 71 PROCESS PROGRAMS ........................................................................................................................ - 71 Process Program Deletion By Host.......................................................................................... - 71 Host-Initiated Process Program Upload (Unformatted) ......................................................... - 71 Equipment-Initiated Process Program Download (Unformatted) .......................................... - 73 Process Program Directory Request ....................................................................................... - 73 Host-Initiated Process Program Download (Unformatted) .................................................... - 73 Equipment-Initiated Process Program Upload (Unformatted) .............................................. - 74 T ERMINAL SERVICES .......................................................................................................................... - 74 Host Sends Information to Equipment’s Display Device ........................................................ - 74 Host Sends Multi-block Message to Equipment’s Display Device .......................................... - 75 Operator Sends Information to Host ....................................................................................... - 75 STRIP MAP ......................................................................................................................................... - 76 Get Strip Map Attribute Data ................................................................................................. - 76 S14,F1 Sample Message ........................................................................................................... - 76 S14,F2 Sample Message ........................................................................................................... - 81 Query Cell Status/Cell Grade Data ......................................................................................... - 83 JOB CONTROL .................................................................................................................................... - 84 S3F17/S3F18 Stream Function ................................................................................................ - 84 S14F9/S14F10 Stream Function .............................................................................................. - 85 S16F15/S16F16 Stream Function ............................................................................................ - 86 S16F21/S16F22 Stream Function ............................................................................................ - 88 S16F27/S16F28 Stream Function ............................................................................................ - 88 S16F5/S16F6 Stream Function ................................................................................................ - 88 CALIBRATION RESULT DATA .............................................................................................................. - 89 Get Calibration Data ............................................................................................................... - 89 Calibration Results Object Attribute Table ............................................................................ - 90 Calibration Name and OBJID Mapping ................................................................................. - 91 Content of Attribute “CalData” .............................................................................................. - 92 ERROR MESSAGES............................................................................................................................. - 93 Message Fault Due to Unrecognized Device ID ....................................................................... - 93 Message Fault Due to Unrecognized Stream Type .................................................................. - 93 Message Fault Due to Unrecognized Function Type ............................................................... - 93 Message Fault Due to Illegal Data Format .............................................................................. - 93 Message Fault Due to Transaction Timer Timeout................................................................. - 93 SPOOLING .......................................................................................................................................... - 94 Spooling State Model ............................................................................................................... - 94 Spooling State Transitions ....................................................................................................... - 94 Host Defines Set of Messages to be Spooled ............................................................................ - 95 Define Maximum Number of Messages to Send in Response to S6,F23 ................................. - 95 Request and Delete Spooled Data ............................................................................................ - 95 AUTOMATED MATERIAL MOVEMENT MANAGEMENT ........................................................................... - 96 AGV/OHT Auto Handling System Sequence (Premium Option) ........................................... - 96 KNS Bonder to Host Events And Applicable SVID ................................................................ - 99 ENHANCED OPERATOR DATA ENTRY ................................................................................................. - 99 Page v of 324
Jan 28, 2021 Rev 4.2
Kulicke & Soffa™
SECS/GEM Interface for Ball Bonders
Bonder software version x-xx-x-473-series
Table of Contents
Overview .................................................................................................................................. - 99 Operator Data Entry #1 Dialog - Host Definable Items .......................................................... - 99 Operator Data Entry #2 Dialog - Host Definable Items .......................................................... - 99 4.17 OS FILE DOWNLOAD SCENARIO FOR REMOTE INSTALLATION.......................................................... - 101 4.18 TRACE: EXAMPLE OS_FILE_DWNLD SCENARIO ......................................................................... - 102 4.19 DATA SET T RANSFERS ..................................................................................................................... - 103 Data Set Upload ..................................................................................................................... - 103 Data Set Download ................................................................................................................ - 103 -
5. MESSAGE TRANSFER PROTOCOLS ............................................ - 104 5.1
5.2
HIGH-SPEED SECS MESSAGE SERVICES (HSMS) .......................................................................... - 104 SEMI EQUIPMENT COMMUNICATIONS STANDARD 1 (SECS-I) ......................................................... - 106 -
6. APPENDIX 0 - K&S MODEL POWER SERIES AUTOMATIC BALL
BONDER AND K&S MODEL GEN-S AUTOMATIC BALL BONDER
SHARED ITEMS ......................................................................................... - 107 6.1 INTRODUCTION ................................................................................................................................. - 107 6.2 K&S MODEL POWER SERIES AUTOMATIC BALL BONDER AND K&S MODEL GEN-S AUTOMATIC BALL
BONDER SHARED STATUS VARIABLES ....................................................................................................... - 107 6.3 K&S MODEL POWER SERIES AUTOMATIC BALL BONDER AND K&S MODEL GEN-S AUTOMATIC BALL
BONDER SHARED EQUIPMENT CONSTANTS ............................................................................................... - 149 6.4 K&S MODEL POWER SERIES AUTOMATIC BALL BONDER AND K&S MODEL GEN-S AUTOMATIC BALL
BONDER SHARED COLLECTION EVENTS .................................................................................................... - 170 6.5 K&S MODEL POWER SERIES AUTOMATIC BALL BONDER AND K&S MODEL GEN-S AUTOMATIC BALL
BONDER SHARED ALARMS......................................................................................................................... - 267 6.6 K&S MODEL POWER SERIES AUTOMATIC BALL BONDER AND K&S MODEL GEN-S AUTOMATIC BALL
BONDER SHARED DATA VALUES................................................................................................................ - 302 6.7 K&S MODEL POWER SERIES AUTOMATIC BALL BONDER AND K&S MODEL GEN-S AUTOMATIC BALL
BONDER GEM COMPLIANCE STATEMENT .................................................................................................. - 304 -
7. APPENDIX 3 - SUMMARY OF SOFTWARE CHANGES ............... - 304 8. APPENDIX 4 - SUMMARY OF DOCUMENT CHANGES ............... - 311 9. APPENDIX 5 – KNOWN ISSUES ...................................................... - 312 10. APPENDIX 6 – SAMPLE TRANSACTIONS AND SCENARIOS - 312 10.1 COMMUNICATIONS ............................................................................................................................ - 312 Enable Communications ........................................................................................................ - 312 Equipment Test for Host Online ........................................................................................... - 312 10.2 ALARMS ........................................................................................................................................... - 312 Enable All Alarms ................................................................................................................. - 312 Equipment Generated Alarm ................................................................................................ - 313 10.3 COLLECTION EVENTS AND REPORTS ............................................................................................... - 313 Disable All Collection Events................................................................................................. - 313 Delete All Reports .................................................................................................................. - 313 Delete Specific Reports .......................................................................................................... - 313 Unlink All Reports Linked to Specific Collection Events ..................................................... - 314 Define Reports ....................................................................................................................... - 316 Link Reports to Collection Events......................................................................................... - 317 Enable Specific Collection Events ......................................................................................... - 319 10.4 EQUIPMENT STATUS ......................................................................................................................... - 319 Host Request for Selected Status Variable Values ................................................................ - 319 Event Report From Equipment ............................................................................................. - 320 Page vi of 324
Jan 28, 2021 Rev 4.2
Kulicke & Soffa™
SECS/GEM Interface for Ball Bonders
Bonder software version x-xx-x-473-series
Table of Contents
10.5 DATA SET T RANSFER ....................................................................................................................... - 320 Open Data Set To Upload File ............................................................................................... - 320 Open Data Set to Download File ........................................................................................... - 322 -
Page vii of 324
Jan 28, 2021 Rev 4.2
Kulicke & Soffa™
SECS/GEM Interface for Ball Bonders
Bonder software version x-xx-x-473-series
Figures and Tables
Figure 1 – Corresponding Equipment Software .................................................................................. - 13 Figure 2 - Host-Originated Transactions ............................................................................................ - 15 Figure 3 - Equipment-Originated Transactions ................................................................................... - 16 Figure 4 - SML Data Types vs. SEMI E5 Item Format Codes ............................................................ - 17 Figure 5 – Data Types ....................................................................................................................... - 25 Figure 6 - GEM Communications State Model .................................................................................. - 52 Figure 7 – Communications State Transitions .................................................................................... - 53 Figure 8 – Scenario: Host Attempts to Establish Communications ..................................................... - 54 Figure 9 – Scenario: Host-Initiated Are You There ............................................................................ - 54 Figure 10 – Scenario: Equipment-Initiated Are You There ................................................................. - 54 Figure 11 - GEM Control State Model ............................................................................................... - 55 Figure 12 – Control State Transitions................................................................................................. - 56 Figure 13 – Scenario: Operator Actuates ON-LINE Switch and Host Accepts .................................... - 57 Figure 14 – Scenario: Operator Actuates ON-LINE Switch and Host Denies...................................... - 57 Figure 15 – Scenario: Request or Delete Spooled Data ....................................................................... - 57 Figure 16 – Scenario: Operator Sets Switch from LOCAL to REMOTE............................................. - 57 Figure 17 – Scenario: Operator Sets Switch from REMOTE to LOCAL............................................. - 57 Figure 18 – Scenario: Host Sets Equipment OFF-LINE ..................................................................... - 57 Figure 19 – Scenario: Host Sets Equipment ON-LINE ....................................................................... - 58 Figure 20 - K&S Model Power Series Automatic Ball Bonder and K&S Model Gen-S Automatic Ball
Bonder ........................................................................................................................................ - 58 Figure 21 – State Changes for Process Model. ................................................................................... - 59 Figure 22 – Scenario: Collection Event Occurs on the Equipment ...................................................... - 60 Figure 23 – Scenario: Host Requests Collection Event Report............................................................ - 60 Figure 24 – Scenario: Collection Event Report Setup ......................................................................... - 60 Figure 25 – Scenario: Host Requests Report ...................................................................................... - 61 Figure 26 – Scenario: Host Requests Equipment Status Report .......................................................... - 61 Figure 27 – Scenario: Host Requests Equipment Status Namelist ....................................................... - 61 Figure 28 – Scenario: Host Enables or Disables Alarm ...................................................................... - 61 Figure 29 – Scenario: Upload Alarm Information .............................................................................. - 61 Figure 30 – Scenario: Alarm Occurrence Deleted By Equipment ....................................................... - 61 Figure 31 – Scenario: Host Sends Remote Command to Equipment ................................................... - 61 Figure 32 – Scenario: Host Sends New Equipment Constant Value to the Host .................................. - 71 Figure 33 – Scenario: Host Request Equipment Constant Value from Equipment ............................... - 71 Figure 34 – Scenario: Host Requests Equipment Constants Namelist ................................................. - 71 Figure 35 – Scenario: Host Requests Deletion of Process Program ..................................................... - 71 Figure 36 – Scenario: Host Initiated Process Program Upload. ........................................................... - 72 Figure 37 – Scenario: Host Initiated PP Upload using PP_PREP remote command. ........................... - 73 Figure 38 – Scenario: Equipment Initiated Process Program Download.............................................. - 73 Figure 39 – Scenario: Process Program Directory Request ................................................................. - 73 Figure 40 – Scenario: Host-Initiated Process Program Download. ...................................................... - 74 Figure 41 – Scenario: Equipment-Initiated Process Program Upload - Unformatted ........................... - 74 Figure 42 – Scenario: Host Sends Information to Equipment’s Display Device .................................. - 74 Figure 43 – Scenario: Host Sends Multi-block Message to Equipment Display .................................. - 75 Figure 44 – Scenario: Message Fault Due to Unrecognized Device ID ............................................... - 93 Figure 45 – Scenario: Message Fault Due to Unrecognized Stream Type ........................................... - 93 Figure 46 – Scenario: Message Fault Due to Unrecognized Function Type ........................................ - 93 Page viii of 324
Jan 28, 2021 Rev 4.2
Kulicke & Soffa™
SECS/GEM Interface for Ball Bonders
Bonder software version x-xx-x-473-series
Figures and Tables
Figure 47 – Scenario: Message Fault Due to Illegal Data Format ....................................................... - 93 Figure 48 – Scenario: Message Fault Due to Transaction Timer Timeout ........................................... - 93 Figure 49 - GEM Spooling State Model ............................................................................................. - 94 Figure 50 – Scenario: Host Defines Set of Messages to be Spooled .................................................... - 95 Figure 51 – Scenario: Host Defines Maximum Number of Messages to be Sent ................................. - 95 Figure 52 – Scenario: Request and Delete Spooled Data .................................................................... - 96 Figure 53 – AGV/OHT Action .......................................................................................................... - 96 Figure 54 – Host Defineable Operator Entry #1 Dialog Items............................................................. - 99 Figure 55 – Host Defineable Operator Entry #2 Dialog Items........................................................... - 100 Figure 56 - HSMS Protocol Parameters ........................................................................................... - 105 Figure 57 - SECS-I Protocol Parameters .......................................................................................... - 106 Figure 58 – K&S Model Power Series Automatic Ball Bonder and K&S Model Gen-S Automatic Ball
Bonder Shared Status Variables ................................................................................................. - 149 Figure 59 – K&S Model Power Series Automatic Ball Bonder and K&S Model Gen-S Automatic Ball
Bonder Shared Equipment Constants ......................................................................................... - 169 Figure 60 – K&S Model Power Series Automatic Ball Bonder and K&S Model Gen-S Automatic Ball
Bonder Shared Collection Events ............................................................................................. - 266 Figure 61 – K&S Model Power Series Automatic Ball Bonder and K&S Model Gen-S Automatic Ball
Bonder Shared Alarms .............................................................................................................. - 302 Figure 62 – K&S Model Power Series Automatic Ball Bonder and K&S Model Gen-S Automatic Ball
Bonder Shared Data Values ....................................................................................................... - 303 Figure 63 – K&S Model Power Series Automatic Ball Bonder and K&S Model Gen-S Automatic Ball
Bonder GEM Compliance Statement ......................................................................................... - 304 -
Page ix of 324
Jan 28, 2021 Rev 4.2
Kulicke & Soffa™
SECS/GEM Interface for K&S Ball Bonders
Bonder software version x-xx-x-473-series
1.
General Information
This document incorporates the SECS-II Standard Form specified in section 8 of SEMI E5 and complies with the
documentation requirements of SEMI E30. K&S Model Power Series Automatic Ball Bonder and K&S Model Gen-S
Automatic Ball Bonder SECS messaging is described herein. Appendix 0 contains tables of status variables,
equipment constants, collection events, alarms, and data values which are shared by K&S Model Power
Series Automatic Ball Bonder and K&S Model Gen-S Automatic Ball Bonder.
1.1
Introduction
This document describes the SEMI Equipment Communications Standard (SECS) communications interface for the
K&S Model Power Series Automatic Ball Bonder and K&S Model Gen-S Automatic Ball Bonder. It is intended for
use by computer-integrated manufacturing (CIM) personnel who wish to monitor and control the equipment via a
remote host computer.
A working knowledge of the equipment and the following Semiconductor Equipment and Materials International
(SEMI) Equipment Automation/Software Standards is assumed:
• SEMI E4-91 Equipment Communications Standard 1 Message Transfer (SECS-I).
• SEMI E5-96 Equipment Communications Standard 2 Message Content (SECS-II).
• SEMI E30-95 Generic Model for Communications and Control of SEMI Equipment (GEM).
• SEMI E37-95 High-Speed SECS Message Services (HSMS) Generic Services.
• SEMI E37.1-95 High-Speed SECS Message Services Single-Session Mode (HSMS-SS).
• SEMI G84-1101 Specification for Strip Map Protocol (Premium Option)
• SEMI E142 Protocol for Substrate Mapping (Premium Option)
• SEMI E87 Carrier Management (Premium Option)
• SEMI E40 Processing Job Management (Premium Option)
• SEMI E94 Control Job Management (Premium Option)
1.2
Manufacturer and Product Model
K&S Model IConn/IConn PLUS/IConn ProCu/IConn ProCu PLUS/IConn MEM PLUS/RAPID/RAPID Pro/RAPID
MEM Automatic Ball Bonder
K&S Model ConnX/ConnX PLUS/ConnX-LED/ConnX-LED PLUS/ConnX ELITE/ConnX ELITE RPM/ConnX ELITE
Opto/ConnX ELITE Opto RPM/ConnX ELITE VLF/OptoLux/OptoLux VLF Automatic Ball Bonder
1.3
General Description of Equipment Function
The K&S Model Power Series Automatic Ball Bonder and K&S Model Gen-S Automatic Ball Bonder series attach
wires on semiconductor integrated circuit (IC) devices. The machines process wires by means of a thermosonic
bonding process using heat, force and ultrasonic energy to fuse each end of the wire to the device. The machines
feature integrated PRS/Video Lead Locator systems and are equipped with automatic material handling systems.
Intended Function of Interface
The function of the SECS/GEM interface is to allow an external host computer to monitor and control K&S Model
Power Series Automatic Ball Bonder and K&S Model Gen-S Automatic Ball Bonder according to specified SECS-II
message sets and supported GEM capabilities.
Software Version Number
Page - 10 - of 324
Jan 28, 2021 Rev 4.2
Kulicke & Soffa™
SECS/GEM Interface for K&S Ball Bonders
Bonder software version x-xx-x-473-series
Date
03/02/09
BALL BONDER OPERATING SYSTEM SOFTWARE VERSIONS
Software
Document
Model
Version
Revision #
Comments
IConnConnx &
UltraElite
IConnConnx &
UltraElite
IConn/ConnX/ConnX+/
ConnXLED/ProCu &
Ultra/Elite
IConn/ConnX/ConnX+/
ConnXLED/ProCu &
Ultra/Elite
IConn/IConn+/
ConnX/ConnX+/
ConnXLED/ProCu/
ProCu+
IConn/IConn+/
ConnX/ConnX+/
ConnXLED/ProCu/
ProCu+
IConn/IConn+/
ConnX/ConnX+/
ConnXLED/ ProCu/
ProCu+
IConn/IConn+/
ConnX/ConnX+/
ConnXLED/
ConnXLED+ ProCu/
ProCu+
x-xx-x-41A-1
Rev 1.9
See Appendix 3 for change details
x-xx-x-43A-1
Rev 2.0
See Appendix 3 for change details
x-xx-x-446
Rev 2.1
See Appendix 3 for change details
x-xx-x-451
Rev 2.2
See Appendix 3 for change details
x-xx-x-454
Rev 2.3
See Appendix 3 for change details
x-xx-x-455
Rev 2.4
See Appendix 3 for change details
x-xx-x-456
Rev 2.5
See Appendix 3 for change details
x-xx-x-457
Rev 2.6
See Appendix 3 for change details
07/21/15
IConn/IConn+/
ConnX/ConnX+/
ConnXLED/ ProCu/
ProCu+
x-xx-x-458
Rev 2.7
See Appendix 3 for change details
11/19/15
IConn/IConn+/
ConnX/ConnX+/
ConnXLED/ ProCu/
ProCu+
x-xx-x-459
Rev 2.8
See Appendix 3 for change details
02/19/16
IConn/IConn+/
ConnX/ConnX+/
ConnXLED/ ProCu/
ProCu+
x-xx-x-460
Rev 2.9
See Appendix 3 for change details
07/20/16
IConn/IConn+/
ConnX/ConnX+/
ConnXLED/ ProCu/
ProCu+
x-xx-x-461
Rev 3.0
See Appendix 3 for change details
12/27/16
IConn/IConn+/
ConnX/ConnX+/
ConnXLED/ ProCu/
ProCu+
x-xx-x-462
Rev 3.1
See Appendix 3 for change details
04/20/17
IConn/IConn+/
ConnX/ConnX+/
ConnXLED/ ProCu/
ProCu+
IConn/IConn+/
ConnX/ConnX+/
ConnXLED/ ProCu/
ProCu+/ConnXLED+/ConnX ELITE
x-xx-x-463
Rev 3.2
See Appendix 3 for change details
x-xx-x-464
Rev 3.3
See Appendix 3 for change details
09/16/10
02/10/12
05/08/13
01/10/14
06/12/14
09/22/14
01/15/15
09/25/17
Page - 11 - of 324
Jan 28, 2021 Rev 4.2
Kulicke & Soffa™
SECS/GEM Interface for K&S Ball Bonders
Bonder software version x-xx-x-473-series
Date
03/15/18
09/10/18
01/04/19
05/28/19
08/23/19
03/19/20
05/19/20
09/18/20
1/28/21
BALL BONDER OPERATING SYSTEM SOFTWARE VERSIONS
Software
Document
Model
Version
Revision #
Comments
IConn/IConn+/
ConnX/ConnX+/
ConnXLED/ ProCu/
ProCu+/ConnXLED+/ConnX ELITE/
Rapid Pro/OptoLUX
IConn/IConn+/
ConnX/ConnX+/
ConnXLED/ ProCu/
ProCu+/ConnXLED+/IConn MEM
Plus/ConnX ELITE/
Rapid/Rapid
Pro/OptoLUX/ConnX
ELITE Opto
IConn+/ConnX+/
ProCu+/ConnXLED+/IConn MEM
Plus/ConnX ELITE/
Rapid/Rapid
Pro/OptoLUX/ConnX
ELITE Opto
IConn+/ConnX+/
ProCu+/ConnXLED+/IConn MEM
Plus/ConnX ELITE/
Rapid/Rapid
Pro/OptoLUX/ConnX
ELITE Opto
IConn+/ConnX+/
ProCu+/ConnXLED+/IConn MEM
Plus/ConnX ELITE/
Rapid/Rapid
Pro/OptoLUX/ConnX
ELITE Opto
IConn+/ConnX+/
ProCu+/ConnXLED+/IConn MEM
Plus/ConnX ELITE/
Rapid/Rapid
Pro/OptoLUX/ConnX
ELITE Opto
IConn+/ConnX+/
ProCu+/ConnXLED+/IConn MEM
Plus/ConnX ELITE/
Rapid/Rapid
Pro/OptoLUX/ConnX
ELITE Opto/OptoLux
VLF
IConn+/ConnX+/
ProCu+/ConnXLED+/IConn MEM
Plus/ConnX ELITE/
Rapid/Rapid
Pro/OptoLUX/ConnX
ELITE Opto/OptoLux
VLF
IConn+/ConnX+/
ProCu+/ConnXLED+/IConn MEM
Plus/ConnX ELITE/
Rapid/Rapid
Pro/OptoLUX/ConnX
ELITE Opto/OptoLux
VLF
x-xx-x-465
Rev 3.4
See Appendix 3 for change details
x-xx-x-466
Rev 3.5
See Appendix 3 for change details
x-xx-x-467
Rev 3.6
See Appendix 3 for change details
x-xx-x-468
Rev 3.7
See Appendix 3 for change details
x-xx-x-469
Rev 3.8
See Appendix 3 for change details
x-xx-x-470
Rev 3.9
See Appendix 3 for change details
x-xx-x-471
Rev 4.0
See Appendix 3 for change details
x-xx-x-472
Rev 4.1
See Appendix 3 for change details
x-xx-x-473
Rev 4.2
See Appendix 3 for change details
Page - 12 - of 324
Jan 28, 2021 Rev 4.2
Kulicke & Soffa™
SECS/GEM Interface for K&S Ball Bonders
Bonder software version x-xx-x-473-series
Figure 1 – Corresponding Equipment Software
Page - 13 - of 324
Jan 28, 2021 Rev 4.2
Kulicke & Soffa™
SECS/GEM Interface for K&S Ball Bonders
Bonder software version x-xx-x-473-series
2.
SECS-II Message Summary
2.1
Host-Originated Transactions
The following table summarizes the primary SECS-II messages understood by the equipment and the associated
secondary replies (where applicable):
Page - 14 - of 324
Jan 28, 2021 Rev 4.2
Kulicke & Soffa™
SECS/GEM Interface for K&S Ball Bonders
Bonder software version x-xx-x-473-series
Host to Equipment Messages
Primary
SX,F0 Abort Transaction (SXF0)
Secondary
-
S1,F1 Are You There Request (R)
S1,F3 Selected Equipment Status Request (SSR)
S1,F11 Status Variable Namelist Request (SVNR)
S1,F13 Establish Communications Request (CR)
S1,F15 Request OFF-LINE (ROFL)
S1,F17 Request ON-LINE (RONL)
S2,F13 Equipment Constant Request (ECR)
S2,F15 New Equipment Constant Send (ECS)
S2,F17 Date and Time Request (DTR)
S2,F23 Trace Initialize Send (TIS)
S2,F29 Equipment Constant Namelist Request
(ECNR)
S2,F31 Date and Time Set Request (DTS)
S2,F33 Define Report (DR)
S2,F35 Link Event Report (LER)
S2,F37 Enable/Disable Event Report (EDER)
S2,F39 Multi-Block Inquire (MBI)
S2,F41 Host Command Send (HCS)
S2,F43 Reset Spooling Streams and Functions
(RSSF)
S2,F45 Define Variable Limit Attributes (DVLA)
S1,F2 On Line Data (D)
S1,F4 Selected Equipment Status Data (SSD)
S1,F12 Status Variable Namelist Reply (SVNRR)
S1,F14 Establish Communications Request
Acknowledge (CRA)
S1,F16 OFF-LINE Acknowledge (OFLA)
S1,F18 ON-LINE Acknowledge (ONLA)
S2,F14 Equipment Constant Data (ECD)
S2,F16 New Equipment Constant Acknowledge
(ECA)
S2,F18 Date and Time Data (DTD)
S2,F24 Trace Initialize Acknowledge (TIA)
S2,F30 Equipment Constant Namelist (ECN)
S2,F32 Date and Time Set Acknowledge (DTA)
S2,F34 Define Report Acknowledge (DRA)
S2,F36 Link Event Report Acknowledge (LERA)
S2,F38 Enable/Disable Event Report
Acknowledge (EERA)
S2,F40 Multi-Block Grant (MBG)
S2,F42 Host Command Acknowledge (HCA)
S2,F44 Reset Spooling Acknowledge (RSA)
S2,F47 Variable Limit Attribute Request (VLAR)
S4,F19 Transfer Job Create (TJ)
S4,F21 Transfer Job Command (TC)
S4,F27 Handoff Ready (HR)
S4,F33 Handoff Verified (HV)
S2,F46 Variable Limit Attribute Acknowledge
(VLAA)
S2,F48 Variable Limit Attributes Send (VLAS)
S4,F20 Transfer Job Acknowledge (TJA)
S4,F22 Transfer Command Acknowledge (TCA)
-
S5,F3 Enable/Disable Alarm Send (EAS)
S5,F5 List Alarms Request (LAR)
S5,F4 Enable/Disable Alarm Acknowledge (EAA)
S5,F6 List Alarms Data (LAD)
S6,F15 Event Report Request (ERR)
S6,F19 Individual Report Request (IRR)
S6,F23 Request Spooled Data (RSD)
S6,F16 Event Report Data (ERD)
S6,F20 Individual Report Data (IRD)
S6,F24 Request Spooled Data Acknowledgment
Send (RSDAS)
S7,F1 Process Program Load Inquire (PPI)
S7,F3 Process Program Send (PPS)
S7,F5 Process Program Request (PPR)
S7,F17 Delete Process Program Send (DPS)
S7,F2 Process Program Load Grant (PPG)
S7,F4 Process Program Acknowledge (PPA)
S7,F6 Process Program Data (PPD)
S7,F18 Delete Process Program Acknowledge
(DPA)
S7,F20 Current EPPD Data (RED)
S7,F19 Current EPPD Request (RER)
S10,F3 Terminal Display, Single (VTN)
S10,F5 Terminal Display, Multi-Block (VTN)
S14,F1 GetAttr Request (GAR)
S10,F4 Terminal Display, Single Acknowledge
(VTA)
S10,F6 Terminal Display, Multi-Block
Acknowledge (VMA)
S14,F2 GetAttr Data (GAD)
Figure 2 - Host-Originated Transactions
Page - 15 - of 324
Jan 28, 2021 Rev 4.2
Kulicke & Soffa™
SECS/GEM Interface for K&S Ball Bonders
Bonder software version x-xx-x-473-series
2.2
Equipment-Originated Transactions
The following table summarizes the primary SECS-II messages originated by the equipment and the expected
secondary replies (where applicable):
Equipment to Host Messages
Primary
Secondary
SX,F0 Abort Transaction (SXF0)
S1,F1 Are You There Request (R)
S1,F13 Establish Communications Request (CR)
S1,F2 On Line Data (D)
S1,F14 Establish Communications Request
Acknowledge (CRA)
S2,F17 Date and Time Request (DTR)
S2,F18 Date and Time Data (DTD)
S4,F23 Transfer Job Alert (TJA)
S4,F27 Handoff Ready (HR)
S4,F33 Handoff Verified (HV)
S4,F24 Transfer Alert Acknowledge (TLA)
-
S5,F1 Alarm Report Send (ARS)
S5,F2 Alarm Report Acknowledge (ARA)
S6,F1 Trace Data Send (TDS)
S6,F5 Multi-Block Data Send Inquire (MBI)
S6,F11 Event Report Send (ERS)
S6,F2 Trace Data Acknowledge (TDA)
S6,F6 Multi-Block Grant (MBG)
S6,F12 Event Report Acknowledge (ERA)
S7,F1 Process Program Load Inquire (PPI)
S7,F3 Process Program Send (PPS)
S7,F5 Process Program Request (PPR)
S7,F2 Process Program Load Grant (PPG)
S7,F4 Process Program Acknowledge (PPA)
S7,F6 Process Program Data (PPD)
S9,F1 Unrecognized Device ID (UDN)
S9,F3 Unrecognized Stream Type (USN)
S9,F5 Unrecognized Function Type (UFN)
S9,F7 Illegal Data (IDN)
S9,F9 Transaction Timer Timeout (TTN)
S9,F11 Data Too Long (DLN)
S9,F13 Conversation Timeout (CTN) (Note: Not
currently used)
-
S10,F1 Terminal Request (TRN)
S10,F2 Terminal Request Acknowledge (TRA)
S14,F1 GetAttr Request (GAR)
S14,F2 GetAttr Data (GAD)
Figure 3 - Equipment-Originated Transactions
Page - 16 - of 324
Jan 28, 2021 Rev 4.2
Kulicke & Soffa™
SECS/GEM Interface for K&S Ball Bonders
Bonder software version x-xx-x-473-series
3.
SECS-II Message Detail
3.1
Data Items
Complete details of all SECS-II messages supported by the equipment are provided in this section. For enhanced
readability, messages are documented using SECS Message Language (SML) format. Data item names are
presented as comments within each message description. SML data item types map to SEMI E5 item header
format codes as follows:
SML DATA TYPES VS. SEMI E5 ITEM FORMAT CODES
SML
Data Item Type
SEMI E5 (Octal)
L
List
00
B
Binary
10
BL
Boolean
11
A
ASCII
20
J
JIS-8
21
I8
Signed 8-byte integer
30
I1
Signed 1-byte integer
31
I2
Signed 2-byte integer
32
I4
Signed 4-byte integer
34
F8
8-byte floating point
40
F4
4-byte floating point
44
U8
Unsigned 8-byte integer
50
U1
Unsigned 1-byte integer
51
U2
Unsigned 2-byte integer
52
U4
Unsigned 4-byte integer
54
V
Variable
N/A
Figure 4 - SML Data Types vs. SEMI E5 Item Format Codes
Data Dictionary
This section describes the data items used in the SECS-II messages supported by the equipment.
Page - 17 - of 324
Jan 28, 2021 Rev 4.2
Kulicke & Soffa™
SECS/GEM Interface for K&S Ball Bonders
Bonder software version x-xx-x-473-series
Data Types
Name
ACKC5
Format
B[1]
Where
Used
S5F4
S5F2
ACKC6
B[1]
S6F12
ACKC7
B[1]
S7F4
S7F18
ACKC10
B[1]
S10F4,
F6
ACKC13
B
S13F2,
S13F4,
S13F6,
S13F8
ALCD
B[1]
S5F6
Description
Stream
0
>0
1-63
Stream
0
>0
1-63
Stream
0
1
2
4
5
5 acknowledge code.
= accepted
= error, not accepted
= reserved
6 acknowledge code.
= Accepted
= Error, not accepted
= Reserved
7 acknowledge code.
= Accepted
= Permission not granted (busy)
= Length error
= PPID not found
= Mode unsupported (equipment not under
remote control)
6-63
= Reserved
Stream 10 acknowledge code.
0
= Accepted for display
1
= Message will not be displayed
2
= Terminal not available
3-63
= Reserved
Acknowledge code
0 = O.K.
1 = ERROR: Try later.
2 = ERROR: Unknown Data Set Name.
3 = ERROR: Illegal Checkpoint value.
4 = ERROR: Too many open Data Sets.
5 = ERROR: Data set open too many times.
6 = ERROR: No open Data set
7 = ERROR: Cannot Continue
8 = ERROR: End of Data
9 = ERROR: Handle in Use.
10 = ERROR: Pending Transaction.
Alarm code.
bit 8
= 1 means alarm set
bit 8
= 0 means alarm cleared
bits 7 - 1 is alarm category code:
0
= Not used
1
= Personal safety
2
= Equipment safety
3
= control warning
4
= Parameter control error
5
= Irrecoverable error
6
= Equipment status warning
7
= Attention flags
8
= Data integrity
>8
= Other categories
9-63
= Reserved
Page - 18 - of 324
Jan 28, 2021 Rev 4.2
Kulicke & Soffa™
SECS/GEM Interface for K&S Ball Bonders
Bonder software version x-xx-x-473-series
Data Types
Name
ALED
Format
B[1]
Where
Used
S5F3
ALID
U2[1]
ALTX
CEED
A[40]
BL[1]
S5F3,
F5, F6
S5F6
S2F37
CEID
U2[1]
COMMACK
B[1]
CKPNT
CPACK
54
B[1]
S13F3,F6
CPNAME
A[40]
CPVAL
DATAID
V
U2[1]
S2F41,
S2F42
S2F41
S2F33,
F35, F45;
S6F5,
F11, F16
DATALENGTH
U4[1]
DRACK
B[1]
DSNAME
A
S13F1,
S13F2
S13F3,
S13F4
DSPER
A[6]
S2F23
S2F35,
F37;
S6F11,
F15
S1F14
S2F42
S2F39;
S6F5.
S2F34
Description
Alarm enable/disable code.
bit 8
= 1 means enable alarm
bit 8
= 0 means disable alarm
Alarm identification.
Alarm text, limited to 40 characters.
Collection event enable/disable code.
FALSE = Disable
TRUE = Enable
Collection event ID.
Communications acknowledge code.
0
= Accepted
1
= Denied, try again
2-63
= Reserved
Checkpoint as defined by the sending system
Command parameter acknowledge code.
1
= Parameter name does not exist
2
= Illegal value specified
3
= Illegal format specified for CPVAL
4-63
= Reserved
Command parameter name.
Command parameter value.
Data ID.
In SECS-I environments, the equipment uses the DATAID to
match a multi-block S2F33,F35,F45 with the corresponding
S2F39/40 multi-block inquire/grant. Therefore, the host should
only use a non-zero DATAID when the S2F33,F35,F45
message will be multi-block. If the S2F33,35,45 message is
single-block, the DATAID must be 0.
In HSMS environments, messages are always a single block
and the DATAID must always be 0.
Total bytes to be sent.
Define report acknowledge code.
0
= Accepted
1
= Denied. Insufficient space
2
= Denied. Invalid format
3
= Denied. At least one RPTID already defined
4
= Denied. At least one VID does not exist
5
= DATAID Not found or other internal error
6-63
= Reserved
Data Set Name - logical name that has meaning to both the
bonder and the host.
• PACKAGE_INF - associated with the data file
(PACKAGE.INF) that contains requirements for
installing bonder software.
• PACKAGE_TAR - associated with the files needed to
install bonder software.
Data sample period, format hhmmss
Page - 19 - of 324
Jan 28, 2021 Rev 4.2
Kulicke & Soffa™
SECS/GEM Interface for K&S Ball Bonders
Bonder software version x-xx-x-473-series
Data Types
Name
DVVAL
EAC
Format
V
B[1]
Where
Used
S6F11
S2F16
ECDEF
ECID
V
U2[1]
ECMAX
ECMIN
ECNAME
ECV
V
V
A[40]
V
EQNAME
ERACK
A[40]
B[1]
S2F30
S2F13,
F15, F29,
F30
S2F30
S2F30
S2F30
S2F14,
F15
S4F27
S2F38
FCNID
U1[1]
FILDAT
GRANT
B
B[1]
S2F43,
F44
S13F6
S2F40
GRANT6
B[1]
S6F6
HANDLE
U2
HCACK
B[1]
S13F3,
13F4,
S13F5,
13F6,
S13F7,
S1F8
S2F42
HOACK
BL[1]
S4F33
Description
Data value.
Equipment acknowledge code.
0
= Acknowledge
1
= Denied. At least one constant does not exist
2
= Denied. Busy
3
= Denied. At least one constant out of range
4-63
= Reserved
Equipment constant default value.
Equipment constant ID.
Equipment constant maximum value.
Equipment constant minimum value.
Equipment constant name.
Equipment constant value.
Equipment name. Note: Not used, always set to empty string ''.
Enable/disable event report acknowledge code.
0
= Accepted
1
= Denied. At least CEID does not exist
2-63
= Reserved
Function identification.
Data from the data set.
Grant code.
0
= Positive response, load OK
1
= Busy, try again
2
= No space
3
= Duplicate name
4-63
= Reserved
Permission to send.
0
= Permission granted
1
= Busy, try again
2
= Not interested
3-63
= Reserved
Logical unit or channel. Used to keep track of the state of a
particular data set and instance of OPEN between the host and
the bonder.
Host command parameter acknowledge code.
0
= Acknowledge; command has been performed
1
= Command does not exist
2
= Cannot perform now
3
= At least one parameter is invalid
4
= Acknowledge; command will be performed
5
= Rejected; already in desired condition
6
= Unable to perform, Internal error occurred.
7-63
= Reserved
Status of corresponding handoff activity.
FALSE = Fail
TRUE = Success
Page - 20 - of 324
Jan 28, 2021 Rev 4.2
Kulicke & Soffa™
SECS/GEM Interface for K&S Ball Bonders
Bonder software version x-xx-x-473-series
Data Types
Name
LENGTH
LIMITACK
Format
U4[1]
B[1]
Where
Used
S7F1
S2F46
LIMITID
B[1]
S2F45,
F46, F48
LIMITMAX
V
S2F48
LIMITMIN
V
S2F48
LOWERDB
V
LRACK
B[1]
S2F45,
F46, F48
S2F36
LVACK
B[1]
S2F46
MDLN
A[6]
MHEAD
B[10]
OFLACK
B[1]
S1F2,
F13, F14
S9F1,
F3, F5,
F7
S1F16
ONLACK
B[1]
S1F18
PPBODY
B[N]
S7F3, F6
Description
Process program body (PPBODY) length, in bytes.
Variable limit attribute set acknowledge code.
0
= Accepted
1
= LIMITID does not exist
2
= UPPERDB > LIMITMAX
3
= LOWERDB < LIMITMIN
4
= UPPERDB < LOWERDB
5
= Illegal UPPERDB or LOWERDB format
6
= ASCII value cannot be translated to numeric
7
= Duplicate LIMITID
8
= Other error
9-63
= Reserved
The identifier of a specific limit in a set of limits.(as defined by
UPPERDB and LOWERDB) for a variable to which the limits
refer.
The maximum value for the limit values of a specific variable.
The format must match that of the referenced variable.
The minimum value for the limit values of a specific variable.
The format must match that of the referenced variable.
The lower boundary of the deadband of a limit. The value
applies to a single limit (LIMITID) for a specified VID.
Link report acknowledge code.
0
= Accepted
1
= Denied. Insufficient space
2
= Denied. Invalid format
3
= Denied. At least one CEID link already defined
4
= Denied. At least one CEID does not exist
5
= Denied. At least one RPTID does not exist
6
= Denied. Invalid DATAID or internal runtime error
7-63
= Reserved
Variable limit definition acknowledge code.
0
= Accepted
1
= Variable does not exist
2
= Variable has no limits capability
3
= Variable repeated in message
4
= Limit value error as described in LIMITACK
5-63
= Reserved
Model number; a constant ASCII field. Content is an equipmentspecific EC.
The header of a message containing an error (SECS-I format).
The block number in MHEAD will be a constant 0, regardless of
the message transport protocol in use.
OFF-LINE request acknowledge code.
0
= OFF-LINE acknowledge
1-63
= Reserved
ON-LINE request acknowledge code.
0
= ON-LINE accepted
1
= ON-LINE not allowed
2
= Equipment already ON-LINE
3-63
= Reserved
Process program body. Maximum N (approximate) = 232
(HSMS) or 7.9Mb (SECS-I).
Page - 21 - of 324
Jan 28, 2021 Rev 4.2
Kulicke & Soffa™
SECS/GEM Interface for K&S Ball Bonders
Bonder software version x-xx-x-473-series
Data Types
Name
PPGNT
Format
B[1]
Where
Used
S7F2
PPID
A[80]
S7F1,
F3, F5,
F6, F17,
F20
RCMD
A[20]
S2F41
READLEN
U4
S13F5
RECLEN
REPGSZ
RPTID
3(),5()
RSDA
B[1]
S13F4
S2F23
S2F33,
F35;
S6F11,
F16
S6F24
RSDC
U1[1]
S6F23
RSPACK
B[1]
S2F44
RTYPE
U2
S13F4
SHEAD
B[10]
S9F9
SMPLN
SOFTREV
<U,I>
A[6]
S6F1
S1F2,
F13, F14
U4[1]
U2[1]
Description
Process program grant status.
0
= OK
1
= Already have
2
= No space
3
= Invalid PPID
4
= Busy, try later
5
= Will not accept
6
= other errors
7
= No PFF file is installed (Customization)
8-63
= Reserved
Process program ID. This is the name of the process program:
If PPSelectMode = 0, use standard DOS compatible “8.3”
format.
If PPSelectMode = 1, use 80 characters maximum.
The host system must first determine the process program
select mode of the equipment by requesting the PPSelectMode
status variable (SVID3106). Currently, the process program
select mode can only be set manually at the equipment.
Remote command code. Case is not significant and dashes ‘-‘
may be substituted for underscores ‘_’. See section 4.6 for
more information regarding remote commands.
Maximum number of data bytes that the bonder is able to
process at one time.
Note: 20% of available contiguous RAM is assigned to
READLEN.
Maximum length of a Discrete record
Reporting group size.
Report ID.
Request spool data acknowledge.
0
= OK
1
= Denied, busy try later
2
= Denied, spooled data does not exist
3-63
= Reserved
Request spool data code.
0
= Transmit spooled messages
1
= Purge spooled messages
2-63
= Reserved
Reset spooling acknowledge.
0
= Acknowledge, spooling setup accepted
1
= Spooling setup rejected
2- 63 = Reserved
Type of record.
0 = stream
Stored header related to a transaction timer timeout (SECS-I
format). The block number in SHEAD will be a constant 0,
regardless of the message transport protocol in use.
Sample Number
The software revision code; a constant ASCII field. Content is
an equipment-specific EC.
Page - 22 - of 324
Jan 28, 2021 Rev 4.2
Kulicke & Soffa™
SECS/GEM Interface for K&S Ball Bonders
Bonder software version x-xx-x-473-series
Data Types
Name
Format
Where
Used
S6F1
S6F24
STIME
STRACK
A [12]
STRID
U1[1]
SV
V
SVID
U2[1]
SVNAME
TEXT
A[40]
A[80]
TIAACK
B[1]
S2F43,
F44
S1F4;
S6F1
S1F3,
F11, F12;
S2F23,
S2F33
S1F12
S10F3,
F5
S2F24
TIACK
B[1]
S2F32
TID
B[1]
S10F3,
F5
TIME
A[12]
TOTSMP
TRACK
U4[1]
BL[1]
S2F18,
F31
S2F23
S4F20,
F22, F23
TRATOMICID
U2[1]
S4F20
TRAUTOSTART
BL[1]
S4F19
TRCMDNAME
A[40]
S4F21
B[1]
Description
Sample Time. 12 byte format YYMMDDhhmmss
Spool stream acknowledge.
1
= Spooling not allowed for stream (i.e. S1).
2
= Stream unknown.
3
= Unknown function specified for this stream.
4
= Secondary function specified for this stream.
Stream identification.
Status variable value.
Status variable ID. Status variables may include any parameter
that can be sampled in time such as temperature or quantity of
a consumable.
Status variable name.
A single line of characters.
Trace acknowledge code.
0
= Accepted
1
= Too many SVIDs
2
= No more traces allowed
3
= Invalid period
4
= Rejected
5-63
= Reserved
Time acknowledge code.
0
= OK
1
= Error, not done
2-63
= Reserved
Terminal number.
0
= Display message on the equipment’s display device
after
the Msg button is selected.
1
= Display message directly on the equipment’s display
device when received.
Time of day, 12 bytes, format yymmddhhmmss.
Total samples to be made.
Status of related transfer activity.
FALSE = Fail
TRUE = Success
Equipment assigned identifier for an atomic transfer.
Value expected to be equal to TRLINK in S4F19.
For each atomic transfer, this data item tells the equipment if it
should automatically start the handoff when ready (=TRUE) or
wait for the host's "Start Handoff" command (=FALSE) following
setup.
This data item only affects the primary transfer.
Note: Always set to TRUE; equipment awaits host start
command.
Identifier of the transfer job related command to be executed.
Possible values: "ABORT"
Page - 23 - of 324
Jan 28, 2021 Rev 4.2
Kulicke & Soffa™
SECS/GEM Interface for K&S Ball Bonders
Bonder software version x-xx-x-473-series
Data Types
Name
TRDIR
Format
U1[1]
Where
Used
S4F19
TRID
U2[1]
TRJOBID
B[1]
TRJOBMS
U1[1]
S2F23,
S6F1
S4F20,
F21, F23
S4F23
TRJOBNAME
A[40]
TRLINK
U2[1]
TRLOCATION
U2[1]
TROBJNAME
A[40]
TROBJTYPE
U2[1]
TRPORT
U1[1]
TRPTNR
A[40]
S4F19,
F27
TRPTPORT
U2[1]
S4F19,
F27
TRRCP
A[40]
S4F19
TRROLE
U1[1]
S4F19,
F27
TRTIMEOUT
U2[1]
TRTYPE
U1[1]
S4F19,
F27
UNITS
A[N]
UPPERDB
V
S1F12;
S2F30,
F48
S2F45,
F46, F48
S4F19,
F23
S4F19,
F27, F33
S4F19,
F27
S4F19,
F23, F27
S4F19,
F27
S4F19,
F27
Description
Direction of handoff as seen from the equipment.
1
= Send material.
2
= Receive material.
Trace request ID.
Equipment assigned identifier for the transfer job.
Note: Always set to 1.
Milestone for a transfer job (e.g. started or complete).
1
= Transfer job started.
2
= Transfer job completed
Host assigned identifier for the transfer job.
Note: Not used, always set to empty string ''.
Common identifier for the atomic transfer used by the transfer
partners to confirm that they are working on the same hostdefined task.
Identifier of the material location involved with the transfer.
Note: Not used; always set to 0.
Identifier for the material (transfer object) to be transferred.
Type of object to be transferred.
0
= Magazine
Identifier of the equipment port to be used for the handoff.
1
= Port 1: preprocess load port
2
= Port 2: preprocess unload port
3
= Port 3: postprocess load port
4
= Port 4: postprocess unload port
Name of the equipment that will serve as the other transfer
partner for this atomic transfer. This corresponds to EQNAME.
Note: Not used; always set to empty string ''.
Identifier of the transfer partner's port to be used for the
transfer.
Note: Not used; always set to 0.
Name of the transfer recipe for this transfer.
Note: Not used; always set to empty string ''.
Tells whether the equipment is to be an active or passive
(primary / secondary) participant in the transfer.
1
= Primary transfer partner
2
= Secondary transfer partner
Note: Equipment is the Secondary transfer partner (2).
Maximum time to wait in state "AWAITING XFR PARTNER" in
seconds.
Tells whether the equipment is to be an active or passive
participant in the transfer.
1
= Active (Track Robot)
2
= Passive (Equipment)
Units identifier.
The upper boundary of the deadband of a limit. The value
applies to a single limit (LIMITID) for a specified VID.
Page - 24 - of 324
Jan 28, 2021 Rev 4.2
Kulicke & Soffa™
SECS/GEM Interface for K&S Ball Bonders
Bonder software version x-xx-x-473-series
Data Types
Name
VID
Format
U2[1]
VLAACK
B[1]
Where
Used
S2F45,
F46, F47,
F48
S2F46
Description
Variable ID.
Variable limit attribute acknowledge code.
0
= Accepted
1
= Limit attribute definition error
2
= Cannot perform now, equipment busy
3
= Other equipment-specific error
4-63
= Reserved
Figure 5 – Data Types
Page - 25 - of 324
Jan 28, 2021 Rev 4.2
Kulicke & Soffa™
SECS/GEM Interface for K&S Ball Bonders
Bonder software version x-xx-x-473-series
Status Variables
The status variables (SVs) and associated status variable ID (SVID) provided by the equipment are described in the
equipment specific appendices.
Equipment Constants
The equipment constant values (ECVs) and associated equipment constant IDs (ECIDs) provided by the equipment
are described in the equipment specific appendices.
Collection Events
The collection events (CEs) and associated collection event ID (CEID) provided by the equipment are described in
the equipment specific appendices.
Alarms
The Alarms and associated Alarm IDs (ALID) provided by the equipment are described in the equipment specific
appendices.
3.2
Host-Originated Transactions
This section details the primary SECS-II messages understood by the equipment and the associated secondary
replies (where applicable).
Sx,F0 Abort Transaction (SxF0)
Usage:
S,H->E
Description: Used with all streams in lieu of an expected message to abort a transaction.
Structure:
Header-only.
S1,F1 Are You There Request (R)
Usage:
S,H->E,reply
Description: Used to test whether the equipment is on-line. A function 0 response to S1,F1 indicates SECS
communication is inoperative (equivalent to a T3 (reply) timeout at the host). While
communications are established, the host may issue this message at any time to test the SECS
link.
Structure:
Header-only.
S1,F2 On Line Data (D)
Usage:
S,H<-E
Description: Equipment reply to host-originated S1,F1.
Structure:
<L[2]
<A[MAX 6]>
<A[MAX 6]>
>.
* MDLN
* SOFTREV
S1,F3 Selected Equipment Status Request (SSR)
Usage:
S,H->E,reply
Description: Used to request the values of selected status variables.
Structure:
<L[MAX N]
<U2[1]>
* SVID1
.
.
.
<U2[1]>
* SVIDN
>.
Notes:
If N=0, then KGem will report all known SVs in ascending SVID order. ECVs may not be requested
via this message. The older (alternative) format of this message is not supported.
Page - 26 - of 324
Jan 28, 2021 Rev 4.2
Kulicke & Soffa™
SECS/GEM Interface for K&S Ball Bonders
Bonder software version x-xx-x-473-series
S1,F4 Selected Equipment Status Data (SSD)
Usage:
S,H<-E
Description: Returned by the equipment to report the SV values in the order requested.
Structure:
<L[MAX N]
<V>
* SV1
.
.
.
<V>
* SVN
>.
Notes:
A zero-length list (<L[0]>) returned for SVi means that SVIDi has not been defined to KGem.
S1,F11 Status Variable Namelist Request (SVNR)
Usage:
S,H->E,reply
Description: This message is used by the host to request identification of certain status variables.
Structure:
<L[MAX N]
<U2[1]>
* SVID1
.
.
.
<U2[1]>
* SVIDN
>.
Notes:
If N=0, then KGem will report all known SVs in ascending SVID order. ECVs may not be requested
via this message.
S1,F12 Status Variable Namelist Reply (SVNRR)
Usage:
S,H<-E
Description: Returned by the equipment to report the requested SV information.
Structure:
<L[MAX N]
<L[3]1
<U2[1]>
* SVID1
<A[MAX 40]>
* SVNAME1
<A[MAX N]>
* UNITS1
>
.
.
.
<L[3]N
<U2[1]>
<A[MAX 40>
<A[MAX N]>
Notes:
* SVIDN
* SVNAMEN
* UNITSN
>
>.
A zero-length name and units (<A[0]>) returned for SVi means that SVIDi has not been defined to
KGem.
S1,F13 Establish Communications Request (CR)
Usage:
S,H->E,reply
Description: Used by the host to attempt to initialize communications with the equipment.
Structure:
<L[0]>.
Page - 27 - of 324
Jan 28, 2021 Rev 4.2
Kulicke & Soffa™
SECS/GEM Interface for K&S Ball Bonders
Bonder software version x-xx-x-473-series
S1,F14 Establish Communications Request Acknowledge (CRA)
Usage:
S,H<-E
Description: Equipment reply to host-originated S1,F13.
Structure:
<L[2]
<B[1]>
* COMMACK
<L[2]
<A[MAX 6]>
* MDLN
<A[MAX 32]>
* SOFTREV
>
>.
S1,F15 Request OFF-LINE (ROFL)
Usage:
S,H->E,reply
Description: Used by the host to request equipment transition to the OFF-LINE control state.
Structure:
Header-only.
S1,F16 OFF-LINE Acknowledge (OFLA)
Usage:
S,H<-E
Description: OFF-LINE request acknowledge or error.
Structure:
<B[1]>.
* OFLACK
S1,F17 Request ON-LINE (RONL)
Usage:
S,H->E,reply
Description: Used by the host to request equipment transition to the ON-LINE control state.
Structure:
Header-only.
S1,F18 ON-LINE Acknowledge (ONLA)
Usage:
S,H<-E
Description: ON-LINE request acknowledge or error.
Structure:
<B[1]>.
* ONLACK
S2,F13 Equipment Constant Request (ECR)
Usage:
S,H->E,reply
Description: Used by the host to request current equipment constant values from the equipment.
Structure:
<L[N]
<U2[1]>
* ECID1
.
.
.
<U2[1]>
* ECIDN
>.
Notes:
SVs may not be requested via this message. The older (alternative) format of this message will not
be supported.
S2,F14 Equipment Constant Data (ECD)
Usage:
S,H<-E
Description: Equipment response to S2,F13. ECVs are reported in the order requested.
Structure:
<L[N]
<V>
* ECV1
.
.
.
<V>
* ECVN
>. Notes:
A zero-length list returned for ECVi means that ECIDi does not exist.
S2,F15 New Equipment Constant Send (ECS)
Usage:
S,H->E,reply
Page - 28 - of 324
Jan 28, 2021 Rev 4.2
Kulicke & Soffa™
SECS/GEM Interface for K&S Ball Bonders
Bonder software version x-xx-x-473-series
Description:
Structure:
The host directs the equipment to change specific equipment constants. The equipment is
responsible for validating new equipment constant values. New values will take effect as soon as
possible.
<L[N]
<L[2]1
<U2[1]>
* ECID1
<V>
* ECV1
>
.
.
.
<L[2]N
<U2[1]>
* ECIDN
<V>
* ECVN
>
>.
S2,F16 New Equipment Constant Acknowledge (ECA)
Usage:
S,H<-E
Description: Equipment response to S2,F15. Any error will cause the entire message to be rejected. Partial
updates will not be performed.
Structure:
<B[1]>.
* EAC
S2,F17 Date and Time Request (DTR)
Usage:
S,H->E,reply
Description: Used by the host to request the current date and time from the equipment.
Structure:
Header-only.
S2,F18 Date and Time Data (DTD)
Usage:
S,H<-E
Description: Actual time data, equipment response to S2,F17.
Structure:
<A[12]>.
* TIME
Notes:
A zero length item means no time exists.
S2,F23 Trace Initialize Send (TIS)
Usage:
S,H->E,reply
Description: Method for sampling selected status variables as a function of time.
Structure:
<L[5]
<U2[1]>
*TRID
<A[6]>
*DSPER
<U4[1]>
*TOTSMP
<U4[1]>
*REPGSZ
<L[N]>
<U2[1]>
*SVID1
.
.
.
<U2[1]>
*SVIDN
>
>.
Notes:
Only 4 active traces can be supported. New trace can only be added when active trace is
terminated (TOTSMP=0)
S2,F24 Trace Initialize Acknowledge (TIA)
Usage:
S,H<-E
Description: Acknowledge or error.
Page - 29 - of 324
Jan 28, 2021 Rev 4.2
Kulicke & Soffa™
SECS/GEM Interface for K&S Ball Bonders
Bonder software version x-xx-x-473-series
Structure:
<B[1]>
*TIAACK
S2,F29 Equipment Constant Namelist (ECNR)
Usage:
S,H->E,reply
Description: This function allows the host to retrieve basic information about what equipment constants are
available in the equipment.
Structure:
<L[N]
<U2[1]>
* ECID1
.
.
.
<U2[1]>
* ECIDN
>.
Notes:
A zero-length list means send information for all ECIDs.
S2,F30 Equipment Constant Namelist (ECN)
Usage:
S,H<-E
Description: Data response to S2,F29 message.
Structure:
<L[N]
(number of equipment constants)
<L1[6]
<U2[1]>
* ECID1
<A[MAX 40]>
* ECNAME1
<V>
* ECMIN1
<V>
* ECMAX1
<V>
* ECDEF1
<A[MAX N]>
* UNITS1
>
.
.
.
<LN[6]
<U2[1]>
* ECIDN
<A[MAX 40]>
* ECNAMEN
<V>
* ECMINN
<V>
* ECMAXN
<V>
* ECDEFN
<A[MAX N]>
* UNITSN
>
>.
S2,F31 Date and Time Set Request (DTS)
Usage:
S,H->E,reply
Description: The host requests the equipment to set its internal clock to the indicated TIME.
Structure:
<A[12]>.
* TIME
S2,F32 Date and Time Set Acknowledge (DTA)
Usage:
S,H<-E
Description: Acknowledge the receipt of the date and time.
Structure:
<B[1]>.
* TIACK
S2,F33 Define Report (DR)
Usage:
S,H->E,reply
Description: Used by the host to associate equipment variables with discrete reports to be provided with
collection events. Association is performed by grouping specific equipment-defined VIDs with hostdefined RPTIDs.
In SECS-I environments, if this message is multi-block, then it must be preceded by a successful
S2,F39/S2,F40 Inquire/Grant transaction.
Page - 30 - of 324
Jan 28, 2021 Rev 4.2
Kulicke & Soffa™
SECS/GEM Interface for K&S Ball Bonders
Bonder software version x-xx-x-473-series
Structure:
<L[2]
<U2[1]>
<L[N]
* DATAID
<L1[2]
<U2[1]>
<L[M]
* RPTID1
<U2[1]> * SVID1
.
.
.
<U2[1]> * SVIDM
>
>
.
.
.
<LN[2]
<U2[1]>
<L[M]
* RPTIDN
<U2[1]> * SVID1
.
.
.
<U2[1]> * SVIDM
>
>
>
>.
S2,F34 Define Report Acknowledge (DRA)
Usage:
S,H<-E
Description: Acknowledge or error. If an error condition is detected the entire message is rejected (i.e. partial
changes are not allowed).
Structure:
<B[1]>.
* DRACK
Page - 31 - of 324
Jan 28, 2021 Rev 4.2
Kulicke & Soffa™
SECS/GEM Interface for K&S Ball Bonders
Bonder software version x-xx-x-473-series
S2,F35 Link Event Report (LER)
Usage:
S,H->E,reply
Description: Used by the host to associate reports with specific collection events on the equipment. Association
is performed by grouping host-defined RPTIDs with equipment-defined CEIDs. A report must be
defined before it is linked to an event (see S2,F33). In SECS-I environments, if this message is
multi-block, then it must be preceded by a successful S2,F39/S2,F40 Inquire/Grant transaction.
Structure:
<L[2]
<U2[1]>
* DATAID
<L[N]
<L1[2]
<U2[1]>
* CEID1
<L[M]
<U2[1]> * RPTID1
.
.
.
<U2[1]> * RPTIDM
>
>
.
.
.
<LN[2]
<U2[1]>
* CEIDN
<L[M]
<U2[1]> * RPTID1
.
.
.
<U2[1]> * RPTIDM
>
>
>
>.
Notes:
If N=0, then all report links will be deleted; report definitions will not be changed. If M=0, then all
report links to the specified CEID will be deleted; otherwise, all report links to the CEID will be
replaced.
There is no explicit limit placed on the number of reports linked to an event. The equipment allows
multiple instances of a report to be linked to an event.
Event reporting links will remain unchanged should the host modify a report via a subsequent
S2,F33 message. The format of the resulting event report messages (S6,F11), however, may
change.
S2,F36 Link Event Report Acknowledge (LERA)
Usage:
S,H<-E
Description: Acknowledge or error. If an error condition is detected the entire message is rejected (i.e. partial
changes are not allowed).
Structure:
<B[1]>.
* LRACK
Page - 32 - of 324
Jan 28, 2021 Rev 4.2
Kulicke & Soffa™
SECS/GEM Interface for K&S Ball Bonders
Bonder software version x-xx-x-473-series
S2,F37 Enable/Disable Event Report (EDER)
Usage:
S,H->E,reply
Description: Used by the host to enable or disable specific event reports on the equipment.
Structure:
<L[2]
<BL[1]>
* CEED
<L[N]
<U2[1]>
* CEID1
.
.
.
<U2[1]>
* CEIDN
>
>.
S2,F38 Enable/Disable Event Report Acknowledge (EERA)
Usage:
S,H<-E
Description: Acknowledge or error. If an error condition is detected the entire message is rejected (i.e. partial
changes are not allowed).
Structure:
<B[1]>.
* ERACK
S2,F39 Multi-Block Inquire (MBI)
Usage:
S,H->E,reply
Description: Used by the host in SECS-I environments to request permission to send a multi block Stream 2
message to the equipment.
Structure:
<L[2]
<U2[1]>
* DATAID
<U4[1]>
* DATALENGTH
>.
S2,F40 Multi-Block Grant (MBG)
Usage:
S,H<-E
Description: Grant permission to send multi-block message.
Structure:
<B[1]>.
* GRANT
S2,F41 Host Command Send (HCS)
Usage:
S,H->E,reply
Description: The host requests the equipment perform a specified remote command.
Structure:
<L[2]
<A[MAX 20]>
* RCMD
<L[MAX 1]
<L[2]
<A[MAX N]>
* CPNAME
<V>
* CPVAL
>
>
>.
Page - 33 - of 324
Jan 28, 2021 Rev 4.2
Kulicke & Soffa™
SECS/GEM Interface for K&S Ball Bonders
Bonder software version x-xx-x-473-series
S2,F42 Host Command Acknowledge (HCA)
Usage:
S,H<-E
Description: Host command acknowledge or error.
Structure:
<L[2]
<B[1]>
* HCACK
<L[1] **
<L[2]
<A[MAX N ]>
* CPNAME
<V>
* CPACK
>
>
>.
Notes:
** If HCACK= 0 or 4 then <L[0]>.
S2,F43 Reset Spooling Streams and Functions (RSSF)
Usage:
S,H->E,reply
Description: This message allows the host to select specific streams and functions to be spooled whenever
spooling is active.
Structure:
<L[M]
<L1[2]
<U1[1]>
* STRID
<L[N]
<U1[1]>
* FCNID1
.
.
.
<U1[1]>
* FCNIDN
>
>
.
.
.
<LM[2]
<U1[1]>
<L[N]
* STRID
<U1[1]>
.
.
.
<U1[1]>
* FCNID1
* FCNIDN
>
Notes:
>
>.
A zero-length list, M=0 turns off spooling for all streams and functions. A zero-length list, N=0, turns
off spooling for all functions for the stream. Spooling for Stream 1 is not allowed. The equipment
must allow the host to spool all primary messages for a stream (except Stream 1). A defined list of
functions for a stream will replace any previously selected functions.
Page - 34 - of 324
Jan 28, 2021 Rev 4.2
Kulicke & Soffa™
SECS/GEM Interface for K&S Ball Bonders
Bonder software version x-xx-x-473-series
S2,F44 Reset Spooling Acknowledge (RSA)
Usage:
S,H<-E
Description: Response to S2,F43 message; acknowledge or error.
Structure:
<L[2]
<B[1]>.
* RSPACK
<L[M]
<L1[3]
<U2[1]>
* STRID1
<B[1]>.
* STRACK1
<L[N]
<U1[1]> * FCNID1
.
.
.
<U1[1]> * FCNIDN
>
>
.
.
.
<LM[3]
<U2[1]>
* STRIDM
<B[1]>
* STRACKM
<L[N]
<U1[1]> * FCNID1
.
.
.
<U1[1]> * FCNIDN
>
>
>
>.
Notes:
If RSPACK = 0, then a zero-length list, M=0 is given, indicating no streams or functions in error. A
zero-length list, N=0, indicates no functions in error for specified.
S2,F45 Define Variable Limit Attributes (DVLA)
Usage:
M,H->E,reply
Description: This message allows the host to define multiple limits to be applied to selected status variables
(SV’s).
Structure:
<L[2]
<U2[1]>
* DATAID
<L[M]
(M = # VIDs)
<L1[2]
<U2[1]>
* VID1
<L[N]
(N = #Limits for this VID)
<L1[2]
<B[1]> * LIMITID1
<L[P]
(p={0,2})
<V>
*UPPERDB
<V>
*LOWERDB
>
>
.
Page - 35 - of 324
Jan 28, 2021 Rev 4.2
Kulicke & Soffa™
SECS/GEM Interface for K&S Ball Bonders
Bonder software version x-xx-x-473-series
.
.
<LN[2]
<B[1]> * LIMITIDN
<L[P]
(p={0,2})
<V>
*UPPERDB
<V>
*LOWERDB
>
>
>
>
.
.
<LM[2]
<U2[1]>
<L[N]
* VIDM
(N = #Limits for this VID)
<L1[2]
<B[1]> * LIMITID1
<L[P]
(p={0,2})
<V>
*UPPERDB
<V>
*LOWERDB
>
>
.
.
.
<LN[2]
<B[1]> * LIMITIDN
<L[P]
(p={0,2})
<V>
*UPPERDB
<V>
*LOWERDB
>
>
>
>
>
Notes:
>.
A zero-length list, M=0, sets all limit values for all monitored VIDs to "undefined.
A zero-length list, N=0, sets all limits values for that VID to "undefined.
A zero-length list, P=0, sets that limit to "undefined."
S2,F46 Variable Limit Attribute Acknowledge (VLAA)
Usage:
M,H<-E,reply
Description: Acknowledge definition of variable limit attributes or report error. If DVLA is not accepted due to
one or more invalid parameters (e.g., LIMITACK=3), then a list of invalid parameters is returned
containing the variable limit attribute and reason for rejection. If an error condition is detected, the
entire message is rejected, i.e., partial changes are not allowed.
Page - 36 - of 324
Jan 28, 2021 Rev 4.2
Kulicke & Soffa™
SECS/GEM Interface for K&S Ball Bonders
Bonder software version x-xx-x-473-series
Structure:
<L[2]
<B[1]>
<L[M]
* VLAACK
<L1[3]
<U2[1]>
<B[1]>
<L[N]
* VID1
* LVACK1
(N={0,2})
<B[1]> * LIMITID1
<B[1]> * LIMITACK1
>
>
.
.
.
<LM[3]
<U2[1]>
<B[1]>
<L[N]
* VIDM
* LVACKM
(N={0,2})
<B[1]> * LIMITIDM
<B[1]> * LIMITACKM
>
>
Notes:
>
>.
A zero-length list, M=0, indicates no invalid variable limit attributes.
A zero-length list, N=0, indicates no invalid limit values for that VID.
S2,F47 Variable Limit Attribute Request (VLAR)
Usage:
S,H->E,reply
Description: This message allows the host to query the equipment for current variable limit attribute definitions.
Structure:
<L[N]
<U2[1]>
* VID1
.
.
.
<U2[1]>
* VIDN
>.
Notes:
A zero-length list, N=0, requests a list of all VID values that can have variable limit attributes.
S2,F48 Variable Limit Attributes Send (VLAS)
Usage:
M,H<-E,reply
Description: Equipment sends values of requested variable limit attribute definitions in the order requested.
Structure:
<L[M]
(M = # VIDs)
<L1[2]
<U2[1]>
* VID1
<L[P]
(P={0,4})
<A[R]
* UNITS1
<V>
* LIMITMIN1
<V>
* LIMITMAX1
<L[N]
<L1[3]
<B[1]> * LIMITID1
<V>
* UPPERDB1
<V>
* LOWERDB1
>
.
Page - 37 - of 324
Jan 28, 2021 Rev 4.2
Kulicke & Soffa™
SECS/GEM Interface for K&S Ball Bonders
Bonder software version x-xx-x-473-series
.
.
<LN[3]
<B[1]> * LIMITIDN
<V>
* UPPERDBN
<V>
* LOWERDBN
>
>
>
>
.
.
.
<LM[2]
<U2[1]>
<L[P]
* VIDM
(P={0,4})
* UNITSM
* LIMITMINM
* LIMITMAXM
<A[R]
<V>
<V>
<L[N]
<L1[3]
<B[1]> * LIMITID1
<V>
* UPPERDB1
<V>
* LOWERDB1
>
.
.
.
<LN[3]
<B[1]> * LIMITIDN
<V>
* UPPERDBN
<V>
* LOWERDBN
>
>
>
>
Notes:
>.
A zero-length list, P=0, indicates that limits are not supported for the VID.
A zero-length list, N=0, indicates that no limits are currently defined for the VID.
S5,F3 Enable/Disable Alarm Send (EAS)
Usage:
S,H->E,reply
Description: Allows the host to selectively enable or disable individual alarms the equipment.
Structure:
<L[2]
<B[1]>
* ALED
<U2[1]>
* ALID
>.
Notes:
A zero length ALID means all alarms.
S5,F4 Enable/Disable Alarm Acknowledge (EAA)
Usage:
S,H<-E
Description: Acknowledge or error.
Structure:
<B[1]>.
* ACKC5
S5,F5 List Alarms Request (LAR)
Usage:
S,H->E,reply
Description: Requests the equipment to provide current alarm information to the host.
Page - 38 - of 324
Jan 28, 2021 Rev 4.2
Kulicke & Soffa™
SECS/GEM Interface for K&S Ball Bonders
Bonder software version x-xx-x-473-series
Structure:
<U2[N]>.
* ALID1,.., ALIDN
S5,F6 List Alarms Data (LAD)
Usage:
S,H<-E
Description: Equipment response to S5,F5. The equipment sends current alarm data to the host.
Structure:
<L[N]
<L1[3]
<B[1]>
* ALCD1
<U2[1]>
* ALID1
<A[MAX 40]>
* ALTX1
>
.
.
.
<LN[3]
<B[1]>
* ALCDN
<U2[1]>
* ALIDN
<A[MAX 40]>
* ALTXN
>
>.
Notes:
If a specified ALID does not exist, then zero-length ALCD and ALTX fields will be returned.
S6,F15 Event Report Request (ERR)
Usage:
S,H->E,reply
Description: Used by the host to request an event report for a given CEID.
Structure:
<U2[1]>.
* CEID
Page - 39 - of 324
Jan 28, 2021 Rev 4.2
Kulicke & Soffa™
SECS/GEM Interface for K&S Ball Bonders
Bonder software version x-xx-x-473-series
S6,F16 Event Report Data (ERD)
Usage:
S,H<-E
Description: Equipment reply to host-originated S6,F15. S6,F16 is identical in format to S6,F11.
Structure:
<L[3]
<U2[1]>
* DATAID
<U2[1]>
* CEID
<L[N]
<L1[2]
<U2[1]>
* RPTID1
<L[M]
<V>
* V1
.
.
.
<V>
* VM
>
>
.
.
.
<LN[2]
<U2[1]>
* RPTIDN
<L[M]
<V>
* V1
.
.
.
<V>
* VM
>
>
>
>.
S6,F19 Individual Report Request (IRR)
Usage:
S,H->E,reply
Description: Used by the host to request a report via RPTID.
Structure:
<U2[1]>
* RPTID
S6,F20 Individual Report Data (IRD)
Usage:
S,H<-E
Description: Equipment reply to host-originated S6,F19.
Structure:
<L[N]
<V>
* V1
.
.
.
<V>
* VN
>.
Notes:
A zero-length list, N=0, means that there are no variables linked to the given RPTID or that the
given RPTID does not exist.
S6,F23 Request Spooled Data (RSD)
Usage:
S,H->E,reply
Description: Host requests transmission or deletion of the messages currently spooled by the equipment.
Structure:
<B[1]>.
* RSDC
S6,F24 Request Spooled Data Acknowledgment Send (RSDAS)
Page - 40 - of 324
Jan 28, 2021 Rev 4.2
Kulicke & Soffa™
SECS/GEM Interface for K&S Ball Bonders
Bonder software version x-xx-x-473-series
Usage:
Description:
Structure:
S,H<-E
Equipment acknowledges the receipt of the S6,F23 message.
<B[1]>.
* RSDA
S7,F1 Process Program Load Inquire (PPI)
Usage:
S,H->E,reply
Description: This message is used by the host to inquire whether or not the equipment will accept the download
of a multi-block process program.
Structure:
<L[2]
<A[MAX 80]>
* PPID
<U4[1]>
* LENGTH
>.
S7,F2 Process Program Load Grant (PPG)
Usage:
S,H<-E
Description: Equipment reply to host-originated S7,F1. Used to acknowledge or reject host request to download
multi-block process program.
Structure:
<B[1]>.
* PPGNT
S7,F3 Process Program Send (PPS)
Usage:
M,H->E,reply
Description: Used by the host to send an existing process program to the equipment.
Structure:
<L[2]
<A[MAX 80]>
* PPID
<B[MAX N]>
* PPBODY
>.
Notes:
The equipment must be in HIT mode in order to use this capability.
S7,F4 Process Program Acknowledge (PPA)
Usage:
S,H<-E
Description: Equipment reply to host-originated S7,F3. Used to acknowledge or reject process program
downloaded from the host.
Structure:
<B[1]>.
* ACKC7
S7,F5 Process Program Request (PPR)
Usage:
S,H->E,reply
Description: Used by the host to request an existing process program from the equipment.
Structure:
<A[MAX 80]>.
* PPID
S7,F6 Process Program Data (PPD)
Usage:
M,H<-E
Description: Equipment reply to host-originated S7,F6. Used to upload process programs from the equipment to
the host.
Structure:
<L[2]
<A[MAX 80]>
* PPID
<B[MAX N]>
* PPBODY
>.
NOTES: If doing an unformatted upload, L[0] returned on the first S7,F6.
S7,F17 Delete Process Program Send (DPS)
Usage:
S,H->E,reply
Description: Host requests the equipment to delete process programs from equipment storage.
Page - 41 - of 324
Jan 28, 2021 Rev 4.2
Kulicke & Soffa™
SECS/GEM Interface for K&S Ball Bonders
Bonder software version x-xx-x-473-series
Structure:
<L[N]
<A[MAX 80]>
.
.
.
<A[MAX 80]>
Notes:
* PPID1
* PPIDN
>.
If N=0, then delete all.
S7,F18 Delete Process Program Acknowledge (DPA)
Usage:
S,H<-E
Description: Acknowledge receipt of S7,F17 message.
Structure:
<B[1]>.
* ACKC7
S7,F19 Current EPPD Request (RER)
Usage:
S,H->E,reply
Description: Used by the host to request the equipment process program directory (EPPD). The EPPD is a list
of all PPIDs currently available for use at the equipment. The equipment must be in HIT mode,
otherwise S7,F20 <L[0]>. is returned.
Structure:
Header-only.
S7,F20 Current EPPD Data (RED)
Usage:
M,H<-E
Description: Used by the equipment to transfer its current EPPD to the host.
Structure:
<L[N]
<A[MAX 80]>
* PPID1
.
.
.
<A[MAX 80]>
* PPIDN
>.
S10,F3 Terminal Display, Single (VTN)
Usage:
S,H->E,reply
Description: The host requests the equipment to display a single line of text on its terminal display.
Structure:
<L[2]
<B[1]>
* TID
<A[MAX 80]>
* TEXT
>.
S10,F4 Terminal Display, Single Acknowledge (VTA)
Usage:
S,H<-E
Description: Equipment response to S10,F3.
Structure:
<B[1]>.
* ACKC10
S10,F5 Terminal Display, Multi-Block(VTM)
Usage:
S,H->E,reply
Description: The host requests the equipment to display multiple lines of text on its terminal display.
Page - 42 - of 324
Jan 28, 2021 Rev 4.2
Kulicke & Soffa™
SECS/GEM Interface for K&S Ball Bonders
Bonder software version x-xx-x-473-series
Structure:
<L[2]
<B[1]>
<L[N]
* TID
<A[MAX 80]>
.
.
.
<A[MAX 80]>
* TEXT
* TEXT
>
>.
S10,F6 Terminal Display, Multi-Block Acknowledge (VMA)
Usage:
S,H<-E
Description: Equipment response to S10,F5.
Structure:
<B[1]>.
* ACKC10
S13,F1 Send Data Set Send (DSSS)
Usage:
S,H<->E,reply
Description: Sent by the sending system to request that the other system read a dataset.
Structure: L,1
1.<DSNAME>
S13,F2 Send Data Set Acknowledge (DSSA)
Usage:
S,H<->E
Description: Sent by the receiving system in response to Send Data Set Send.
Structure: L,2
1. <DSNAME>
2. <ACKC13>
Exceptions: The possible ACKC13 codes for this message are:
0=O.K.
1=ERROR:Try later.
2=ERROR:Unknown Data Set Name.
Page - 43 - of 324
Jan 28, 2021 Rev 4.2
Kulicke & Soffa™
SECS/GEM Interface for K&S Ball Bonders
Bonder software version x-xx-x-473-series
3.3
Equipment-Originated Transactions
This section details the primary SECS-II messages understood by the host and the associated secondary replies
(where applicable).
Sx,F0 Abort Transaction (SxF0)
Usage:
S,H<-E
Description: Used with all streams in lieu of an expected message to abort a transaction.
Structure:
Header-only.
S1,F1 Are You There Request (R)
Usage:
S,H<-E,reply
Description: Used to test host on-line. A function 0 response to S1,F1 indicates SECS communication is
inoperative (equivalent to a T3 (reply) timeout at the equipment). The equipment may issue this
message at any time to test the SECS link.
Structure:
Header-only.
S1,F2 On Line Data (D)
Usage:
S,H->E
Description: Host reply to equipment-originated S1,F1.
Structure:
<L[0]>.
S1,F13 Establish Communications Request (CR)
Usage:
S,H<-E,reply
Description: Used by the equipment to attempt to initialize communications with the host.
Structure:
<L[2]
<A[MAX 6]>
* MDLN
<A[MAX 6]>
* SOFTREV
>.
S1,F14 Establish Communications Request Acknowledge (CRA)
Usage:
S,H->E
Description: Host- reply to equipment originated S1,F13.
Structure:
<L[2]
<B[1]>
* COMMACK
<L[0]>
>.
S5,F1 Alarm Report Send (ARS)
Usage:
S,H<-E,[reply]
Description: Report change in or presence of an alarm condition.
Structure:
<L[3]
<B[1]>
* ALCD
<U2[1]>
* ALID
<A[MAX 40]>
* ALTX
>.
Notes:
A zero-length item means no time exists.
S5,F2 Alarm Report Acknowledge (ARA)
Usage:
Description:
S,H<-E
Host acknowledge alarm send.
<B[1]>.
* ACKC5
Page - 44 - of 324
Jan 28, 2021 Rev 4.2
Kulicke & Soffa™
SECS/GEM Interface for K&S Ball Bonders
Bonder software version x-xx-x-473-series
S6,F1 Trace Data Send
Usage: M,H<-E,[reply]
Description: Used by the equipment to send samples to the host according to the trace setup done by S2,F33.
Structure:
<L[4]
<U2[1]>
*TRID
<U,I>
*SMPLN
<A[12]>
*STIME
<L[N]
<U2[1]>
*SVID
.
.
.
<U2[1]>
*SVID
>
>
Notes: A zero-length STIME means no value is given and that the time is to be derived from SMPLN.
S6,F2 Trace Data Acknowledge
Usage: Acknowledge or error.
Structure:<B[1]>
*ACKC6
S6,F5 Multi-block Data Send Inquire (MBI)
Usage:
S,H<-E,reply
Description: If the discrete data report S6,F3/F9/F11/F13 is more than one block, then inquire if host will accept
the report.
Structure:
<L[2]
<U2[1]>
* DATAID
<U4[1]>
* DATALENGTH
>.
S6,F6 Multi-block Grant (MBG)
Usage:
S,H->E
Description: Acknowledge or error.
Structure:
<B[1]>.
* GRANT6
S6,F11 Event Report Send (ERS)
Usage:
M,H<-E,[reply]
Description: Used by the equipment to notify the host of an event.
Page - 45 - of 324
Jan 28, 2021 Rev 4.2
Kulicke & Soffa™
SECS/GEM Interface for K&S Ball Bonders
Bonder software version x-xx-x-473-series
Structure:
<L[3]
<U2[1]>
<U2[1]>
<L[N]
* DATAID
* CEID
<L1[2]
<U2[1]>
<L[M]
* RPTID1
<V>
.
.
.
<V>
* V1
* VM
>
>
.
.
<LN[2]
<U2[1]>
<L[M]
* RPTIDN
<V>
.
.
.
<V>
* V1
* VM
>
>
>
>.
S6,F12 Event Report Acknowledge (ERA)
Usage:
S,H->E
Description: Acknowledges an event report from the equipment (optional).
Structure:
<B[1]>.
* ACKC6
Notes:
The equipment ignores the value of ACKC6.
S7,F1 Process Program Load Inquire (PPI)
Usage:
S,H<-E,reply
Description: This message is used by the equipment to inquire whether or not the host will accept upload of a
multi-block process program.
Structure:
<L[2]
<A[MAX 80]>
* PPID
<U4[1]>
* LENGTH
>.
S7,F2 Process Program Load Grant (PPG)
Usage:
S,H->E
Description: Host reply to equipment-originated S7,F1. Used to acknowledge or reject equipment request to
upload multi-block process program.
Structure:
<B[1]>.
* PPGNT
S7,F3 Process Program Send (PPS)
Usage:
M,H<-E,reply
Description: Used by the equipment to send an existing process program to the host.
Structure:
<L[2]
<A[MAX 80]>
* PPID
<B[MAX N]>
* PPBODY
>.
S7,F4 Process Program Acknowledge (PPA)
Page - 46 - of 324
Jan 28, 2021 Rev 4.2
Kulicke & Soffa™
SECS/GEM Interface for K&S Ball Bonders
Bonder software version x-xx-x-473-series
Usage:
Description:
Structure:
S,H->E
Host reply to equipment originated S7,F3. Used to acknowledge or reject process program
uploaded from the equipment.
<B[1]>.
* ACKC7
S7,F5 Process Program Request (PPR)
Usage:
S,H<-E,reply
Description: Used by the equipment to request an existing process program from the host.
Structure:
<A[MAX 80]>.
* PPID
S7,F6 Process Program Data (PPD)
Usage:
M,H->E
Description: Host reply to equipment-originated S7,F5. Used to download process programs from the host to
the equipment.
Structure:
<L[2]
<A[MAX 80]>
* PPID
<B[MAX N]>
* PPBODY
>.
Notes:
A zero length list means request denied.
S9,F1 Unrecognized Device ID (UDN)
Usage:
S,H<-E
Description: Sent by the equipment when a message is received containing an unrecognized device ID.
Structure:
<B[10]>.
* MHEAD
Notes:
S9,F2 is not used.
S9,F3 Unrecognized Stream Type (USN)
Usage:
S,H<-E
Description: Sent by the equipment when a message is received containing an unrecognized stream number.
Structure:
<B[10]>.
* MHEAD
Notes:
S9,F4 is not used.
Page - 47 - of 324
Jan 28, 2021 Rev 4.2
Kulicke & Soffa™
SECS/GEM Interface for K&S Ball Bonders
Bonder software version x-xx-x-473-series
S9,F5 Unrecognized Function Type (UFN)
Usage:
S,H<-E
Description: Sent by the equipment when a message is received containing an unrecognized function number.
Structure:
<B[10]>.
* MHEAD
Notes:
S9,F6 is not used.
S9,F7 Illegal Data (IDN)
Usage:
S,H<-E
Description: Sent by the equipment when a message is received containing an invalid data format.
Structure:
<B[10]>.
* MHEAD
Notes:
S9,F8 is not used.
S9,F9 Transaction Timer Timeout (TTN)
Usage:
S,H<-E
Description: Sent by the equipment when a transaction timer times out.
Structure:
<B[10]>.
* SHEAD
Notes:
S9,F10 is not used.
S9,F11 Data Too Long (DLN)
Usage:
S,H<-E
Description: Sent by the equipment when the equipment receives more data than it can handle.
Structure:
<B[10]>.
* MHEAD
Notes:
S9,F12 is not used.
S10, F1 Terminal Request (TRN)
Usage:
S,H<-E,reply
Description: A terminal text message to the host.
Structure:
<L[2]
<B[1]>
<A[MAX 80]>
* TID
* TEXT
>.
S10, F2 Terminal Request Acknowledge (TRA)
Usage:
S,H->E
Description: Acknowledge or error.
Structure:
<B[1]>.
* ACKC10
S13,F3 Open Data Set Request (DSOR)
Usage:
S,H<-E
Description: Sent by the receiving system to open a data set for reading.
Structure:
<L[3]
<U2[1]>
* HANDLE
<A[40]>
*DSNAME
<U4[1]>
*CKPNT
>.
S13,F4 Open Data Set Data (DSOD)
Usage:
S,H->E
Description: Sent by the sending system in response to Open Data Set Request.
Structure:
<L[5]
<U2[1]>
*HANDLE
<A[40]>
* DSNAME
<Bi[1]>
*ACKC13
<U2[1]>
*RTYPE
Page - 48 - of 324
Jan 28, 2021 Rev 4.2
Kulicke & Soffa™
SECS/GEM Interface for K&S Ball Bonders
Bonder software version x-xx-x-473-series
<U4[1]>
*RECLEN
>.
S13,F5 Read Data Set Request (DSRR)
Usage:
S,H<-E
Description:
Sent by the receiving system to read data from an open data set.
Structure:
<L[2]
<U2[1]>
* HANDLE
<U4[1]>
*READLN
>.
S13,F6 Read Data Set Data (DSRD)
Usage:
M,H->E
Description: Sent by the sending system in response to Read Data Set Request.
Structure:
<L[4]
<U2[1]>
*HANDLE
<Bi[ 1 ]>
*ACKC13
<U4[1]>
*CKPNT
<L[1]
<B[RECLEN]>
*FILDAT
>
>.
S13,F7 Close Data Set Send (DSCS)
Usage:
S,H<-E
>
Description: Sent by the receiving system to close an open data set.
Structure:
<L[1]
<U2[1]
*HANDLE
>.
S13,F8 Close Data Set Acknowledge (DSCA)
Usage:
S,H->E
Description: Sent by the sending system in response to Close Data Set Send (DSCS).
Structure:
<L[2]
<U2[1]>
*HANDLE
<Bi[1]>
*ACKC13
>.
S14,F1 GetAttr Request(GAR)
Usage:
Description:
S, H<->E
This message is used to request a set of specified attributes for one or more objects. It consists of
an “object specifier” for the owner of the target objects (the objects of interest), the target object
type, a list of identifiers of the target objects, a filter (a list of qualifying relationships) that limits the
target objects of interest to those that meet all of the qualifications in and the specific attributes
whose values are requested.
The object specifier provides a specification of the owner of the target objects. It contains a
sequence of hierarchical object relationships. Each element of the object specifier indentifies a
specific object instance that is the superior of the following object instance in the sequence. The
last object type designates the type of the target object, and the list of the object indentifiers
indicates the specific instance of tha t type that are of interest. The target type may be omitted only
if object identifiers are unique across all object types and the list of the identifiers is not empty.
Page - 49 - of 324
Jan 28, 2021 Rev 4.2
Kulicke & Soffa™
SECS/GEM Interface for K&S Ball Bonders
Bonder software version x-xx-x-473-series
The object filter is an optional list of qualifications, each of which provides a condition to be applied
to the object instances of interest. Each qualification objects of interest are those that meet all of
the specified qualifications.
The attribute relationship quantifier is a logical binary relationship ATTRRELNi that the specified
qualifying value ATTRDATAi has to be the corresponding attribute of each instance of the desired
object type(s). The objects that are to be qualified with this filter have an attribute value Vi such that
the statement “ATTRDATAi ATTRRELNi Vi” is TRUE. IF ATTRRELNi is omitted, the relationship of
equality is intended.
For ASCII attribute values ATTRDATAi, the characters for question mark “?” and asterisk “*” are
used as “wild characters” to provide filtering for certain object types. The character “?” may be used
in any attribute or key attribute value with an ASCII format to represent “any single character” and
may be repeated. The asterisk character “*” may be similarly used to represent a variable-length
string, including a null string. The string “*x” represents a string of any length that ends in “x”, the
string “x*” represents any string that begins with “x”, and the string “*” represents any string of any
none-zero length. The comparison for text characters is case insensitive.
Equipment is not required to support wild characters in particular, or attribute filters in general.
Structure:
<L[5]
<OBJSPEC>
<OBJTYPE>
<L[i]
<OBJID1>
.
.
<OBJIDi>
>
< L[q]
<L1[3]
<ATTRID1>
<ATTRDATA1>
<ATTRRELEN1>
>
.
.
<Lq[3]
<ATTRID1>
<ATTRDATA1>
<ATTRRELEN1>
>
>
<L[a]
< ATTRID1>
.
.
< ATTRIDa>
>
>.
Notes: If OBJSPEC is a zero-length item, no object specifier is provided. If i = 0, only the filter is to be applied. If q
= 0, no filter is specified. If both I and q = 0, information for all instances of the objects are requested. If a = 0, all
attributes are requested.
S14,F2 GetAttr Data (GAD)
Usage:
M, H<->E
Description: This message is used to transfer the set of requested attributes for the specified objects.
The order of attributes is retained from the primary message.
Structure:
<L[2]
<L[n]
<L[2]
Page - 50 - of 324
Jan 28, 2021 Rev 4.2
Kulicke & Soffa™
SECS/GEM Interface for K&S Ball Bonders
Bonder software version x-xx-x-473-series
<OBJID1>
<L[2]
<ATTRID1>
<ATTRDATA1>
>
.
.
<L[2]
<ATTRIDa>
<ATTRDATAa>
>
>
<L[2]
<OBJIDn>
<L[2]
<ATTRID1>
<ATTRDATA1>
>
.
.
<L[2]
<ATTRIDb>
<ATTRDATAb>
>
>
>
<L[2]
<OBJACK>
<L[p]
<L[2]
<ERRCODE1>
<ERRTEXT1>
>
.
.
<L[2]
<ERRCODEp>
<ERRTEXTp>
>
>
>
>.
Notes: If OBJSPEC is a zero-length item, no object specifier is provided. If n = 0, no objects matched the specified
filter. If p = 0, no errors were detected.
4.
State Models, Capabilities, and Scenarios
The following sections describe the equipment in terms of GEM state models, GEM capabilities, and commonly
used equipment operating scenarios.
4.1
Communications
Communications State Model
The equipment will support the GEM Communications State Model as described by the SEMI E30 standard.
Page - 51 - of 324
Jan 28, 2021 Rev 4.2
Kulicke & Soffa™
SECS/GEM Interface for K&S Ball Bonders
Bonder software version x-xx-x-473-series
1
COMMUNICATIONS
DISABLED
C
ENABLED
2
3
4
NOT COMMUNICATING
10
HOST-INITIATED
CONNECT
EQUIPMENT-INITIATED
CONNECT
WAIT CR
FROM HOST
WAIT DELAY
11
12
8
WAIT TX
COMPLETE
13
5
14
7
6
WAIT CRA
9
COMMUNICATING
Figure 6 - GEM Communications State Model
The Communications State Model may be enabled or disabled (refer to the Communications State Model
equipment constant). If the Communications State Model is enabled, then communications will be established when
an S1,F13 Establish Communications Request (CR)/S1,F14 Establish Communications Request Acknowledge
(CRA) transaction completes successfully. Otherwise, if the Communications State Model is disabled, the S1,F1 Are
You There Request (R)/S1,F2 On Line Data (D) transaction may be used to determine the communications state.
When the Communications State Model is disabled, SECS communications will function in a “connectionless” mode;
the COMMUNICATING sub-state of the model will be assumed.
Page - 52 - of 324
Jan 28, 2021 Rev 4.2
Kulicke & Soffa™
SECS/GEM Interface for K&S Ball Bonders
Bonder software version x-xx-x-473-series
Communications State Transitions
#
CURRENT
STATE
TRIGGER EVENT
NEW
STATE
Action
COMMENT
1
(Entry to
COMMUNICATIONS)
System initialization
System
Default
None
2
DISABLED
ENABLED
None
3
ENABLED
DISABLED
None
SECS-II communications are
prohibited
4
(Entry to ENABLED)
Operator switches from
DISABLED to
ENABLED
Operator switches from
ENABLED to
DISABLED
Any entry to ENABLED
state
The system default may be
set to DISABLED or
ENABLED
SECS-II communications are
enabled
NOT
COMMUNICATING
None
5
(Entry to
EQUIPMENTINITIATED
CONNECT)
(Any entry to NOT
COMMUNI-CATING)
WAIT CRA
6
WAIT CRA
WAIT DELAY
7
WAIT DELAY
8
WAIT DELAY
Connection transaction
failure
Comm-Delay timer
expired
Received a message
other than S1,F13.
Initialize
communication. Set
Comm-Delay timer
"expired." Send
S1,F13
Initialize CommDelay timer
Send S1,F13
May enter from system
initialization to ENABLED or
through operator switch to
ENABLED
Begin the attempt to establish
communications
9
WAIT CRA
COMMUNICATING
10
WAIT CR
FROM HOST
None
Wait for S1,F13 from Host
Received S1,F13
12
(Entry to HOSTINITIATED
CONNECT)
WAIT CR FROM
HOST
WAIT TX COMPLETE
Received expected
S1,F14 with
COMMACK = 0
(Any entry to NOT
COMMUNI-CATING)
Send S1,F14 with
COMMACK = 0
None
Host seeks to establish
communications
Wait for S1,F13 from Host
13
WAIT TX COMPLETE
None
14
COMMUNICATING
WAIT TX
COMPLETE
WAIT CR
FROM HOST
COMMUNICATING
NOT
COMMUNICATING
Communications are
established
Dequeued messages may be
placed in spool buffer as
appropriate
11
S1,F14 transmission
failed
S1,F14 transmission
completed successfully
Communication failure
WAIT CRA
WAIT CRA
Discard message.
No reply. Set CommDelay timer
"expired". Send
S1,F13
None
Dequeue all
messages queued to
send
Wait for timer to expire
Wait for S1,F14. May receive
S1,F13 from Host
Indicates opportunity to
establish communications
Communications established
Figure 7 – Communications State Transitions
In the ENABLED/NOT COMMUNICATING communications state, the equipment will only accept S1,F13 Establish
Communications Request (CR) and stream 9 messages.
When the equipment receives an S1,F13 Establish Communications Request (CR) message it responds with an
S1,F14 Establish Communications Request Acknowledge (CRA) message. If the equipment is ready to establish
communications, then COMMACK is set to 0. Otherwise, COMMACK is set to 1.
When the S1,F14 Establish Communications Request Acknowledge (CRA) Communications message, with
COMMACK = 0, is sent successfully, the equipment changes its communications state from ENABLED/NOT
COMMUNICATING to ENABLED/COMMUNICATING and its control state is set to its default state.
If the equipment receives an the S1,F13 Establish Communications Request (CR) message from the host and the
communications state is already set to ENABLED/COMMUNICATING, then the equipment will respond with an
S1,F14 Establish Communications Request Acknowledge (CRA) reply.
If the S1,F13 Establish Communications Request (CR)/S1,F14 Establish Communications Request Acknowledge
(CRA) transaction is not being used to establish communications (the Communications State Model is disabled), then
the communications state will always be ‘COMMUNICATING’. A status variable (CommEnabled) is used to determine
whether or not the equipment has disabled communications. When the equipment receives an S1,F1 Are You There
Request ® message and communications are enabled, it replies with an S1,F2 On Line Data (D) message. If
communications are disabled the equipment will not respond to any messages received from the host.
Page - 53 - of 324
Jan 28, 2021 Rev 4.2
Kulicke & Soffa™
SECS/GEM Interface for K&S Ball Bonders
Bonder software version x-xx-x-473-series
An equipment constant(DisableCommunicationsStateModel) will determine whether the S1,F13 Establish
Communications Request (CR)/S1,F14 Establish Communications Request Acknowledge (CRA) transaction or the
S1,F1 Are You There Request ®/S1,F2 On Line Data (D) transaction establishes communications.
Host Attempts to Establish Communications
This scenario is used when the communications state model has been enabled.
COMMENT
HOST
EQUIPMENT
COMMENT
Communications state is
ENABLED (any substate).
Establish communications
S1,F13→
request.
S1,F14
Reply COMMACK = 0 and
communications state =
COMMUNICATING.
Figure 8 – Scenario: Host Attempts to Establish Communications
Host-Initiated Are You There
COMMENT
Are You There request.
HOST
EQUIPMENT
COMMENT
S1,F1→
S1,F2
On-Line Data response.
Figure 9 – Scenario: Host-Initiated Are You There
Equipment-Initiated Are You There
COMMENT
On-Line Data response.
HOST
EQUIPMENT
COMMENT
S1,F1
Are You There request.
S1,F2→
Figure 10 – Scenario: Equipment-Initiated Are You There
Page - 54 - of 324
Jan 28, 2021 Rev 4.2
Kulicke & Soffa™
SECS/GEM Interface for K&S Ball Bonders
Bonder software version x-xx-x-473-series
4.2
Control
Control State Model
The equipment will support the GEM Control State Model as described by the SEMI E30 standard.
CONTROL
1
C
OFF-LINE
2
EQUIPMENT
OFF-LINE
12
3
4
C
C
ATTEMPT
ON-LINE
HOST
OFF-LINE
6
7
11
10
5
C
8
LOCAL
REMOTE
9
ON-LINE
Figure 11 - GEM Control State Model
Page - 55 - of 324
Jan 28, 2021 Rev 4.2
Kulicke & Soffa™
SECS/GEM Interface for K&S Ball Bonders
Bonder software version x-xx-x-473-series
Control State Transitions
#
CURRENT
STATE
TRIGGER EVENT
NEW
STATE
Action
COMMENT
1
(Undefined)
Entry into CONTROL
state (system
initialization).
CONTROL
(Substate
conditional on
configuration)
None
Equipment may be configured
to default to ON-LINE or OFFLINE*.
2
(Undefined)
Entry into OFF-LINE
state
OFF-LINE
(Substate
conditional on
configuration.)
None
Equipment may be configured
to default to any substate of
OFF-LINE
3
EQUIPMENTOFFLINE
Operator actuates ONLINE switch
ATTEMPT
ON-LINE
None
Note that an S1,F1 is sent
whenever ATTEMPT ONLINE is activated
4
ATTEMPT ON-LINE
S1,F0
New state
conditional on
configuration
None
This may be due to a
communication failure,** reply
timeout, or receipt of S1,F0.
Configuration may be set to
EQUIPMENT OFF-LINE or
HOST OFF-LINE
5
ATTEMPT ON-LINE
Equipment receives
expected S1,F2
message from the host
ON-LINE
None
Host is notified of transition to
ON-LINE at transition 7.
6
ON-LINE
Operator actuates
OFF-LINE switch
EQUIPMENT
OFF-LINE
None
"Equipment OFF-LINE" event
occurs***. Event reply will be
discarded while OFF-LINE is
active
7
(Undefined)
Entry to ON-LINE state
ON-LINE
(Substate
conditional on
REMOTE/
LOCAL switch
setting.)
None
"Control State LOCAL" or
"Control State REMOTE"
event occurs. Event reported
based on actual ON-LINE
substate activated
8
LOCAL
Operator sets front
panel switch to
REMOTE
REMOTE
None
"Control State REMOTE"
event occurs
9
REMOTE
Operator sets front
panel switch to LOCAL
LOCAL
None
"Control State LOCAL" event
occurs
1
0
ON-LINE
Equipment accepts
"Set OFF-LINE"
message from host
(S1,F15).
HOST OFFLINE
None
"Equipment OFF-LINE" event
occurs
1
1
HOST OFF-LINE
Equipment accepts
host request to go ONLINE (S1,F17).
ON-LINE
None
Host is notified to transition to
ON-LINE at transition 7
1
2
HOST OFF-LINE
Operator actuates
OFF-LINE switch
EQUIPMENT
OFF-LINE
None
"Equipment OFF-LINE" event
occurs
Figure 12 – Control State Transitions
*
The configuration mentioned for transitions 1 and 2 should be a single setting. This would provide the user
with a choice of entering the EQUIPMENT OFF-LINE, ATTEMPT ON-LINE, HOST OFF-LINE, or ON-LINE
states.
**
If SECS-I is used, this means the retry limit RTY is exceeded during the attempt to send a message.
***
Any host initiated transaction open at the equipment must be completed. This may happen either by sending
the appropriate reply to the host prior to sending the event message or by sending an Sx,FO message
following the event message (i.e., after the transaction).
Host Accepts ON-LINE
Page - 56 - of 324
Jan 28, 2021 Rev 4.2
Kulicke & Soffa™
SECS/GEM Interface for K&S Ball Bonders
Bonder software version x-xx-x-473-series
COMMENT
HOST
Host grants ON-LINE.
EQUIPMENT
COMMENT
S1,F1
Equipment requests ON-LINE.
S1,F2→
S6,F11
Acknowledge.
Control state LOCAL or
REMOTE event.
S6,F12→
Figure 13 – Scenario: Operator Actuates ON-LINE Switch and Host Accepts
Host Denies ON-LINE
COMMENT
HOST
EQUIPMENT
COMMENT
S1,F1
Equipment requests ON-LINE.
Host denies ON-LINE.
S1,F0→
Figure 14 – Scenario: Operator Actuates ON-LINE Switch and Host Denies
Operator Sets OFF-LINE
COMMENT
HOST
Acknowledge.
EQUIPMENT
COMMENT
S6,F11
Equipment requests OFF-LINE
event.
S6,F12→
Figure 15 – Scenario: Request or Delete Spooled Data
Operator Sets REMOTE
COMMENT
Acknowledge.
HOST
EQUIPMENT
COMMENT
S6,F11
Control State REMOTE
Event.
S6,F12→
Figure 16 – Scenario: Operator Sets Switch from LOCAL to REMOTE
Operator Sets LOCAL
COMMENT
Acknowledge.
HOST
EQUIPMENT
COMMENT
S6,F11
Control State LOCAL event.
S6,F12→
Figure 17 – Scenario: Operator Sets Switch from REMOTE to LOCAL
Host Sets OFF-LINE
COMMENT
Host requests ON-LINE.
Acknowledge.
HOST
EQUIPMENT
COMMENT
S1,F15→
S1,F0
Equipment is OFF-LINE.
S1,F16
Equipment is ON-LINE,
transitions to default OFF-LINE
state.
S6,F11
Equipment Acknowledges
transition to OFF-LINE state.
S6,F12→
Figure 18 – Scenario: Host Sets Equipment OFF-LINE
Page - 57 - of 324
Jan 28, 2021 Rev 4.2
Kulicke & Soffa™
SECS/GEM Interface for K&S Ball Bonders
Bonder software version x-xx-x-473-series
Host Sets ON-LINE
COMMENT
Host requests ON-LINE.
HOST
Acknowledge.
4.3
EQUIPMENT
COMMENT
S1,F17→
S1,F18
Equipment is not HOST OFFLINE, equipment denies report.
S1,F18
Equipment is HOST OFFLINE, accepts request and
goes to default ON-LINE state.
S6,F11
Equipment Acknowledges
transition to ON-LINE LOCAL
or ON-LINE REMOTE state.
S6,F12→
Figure 19 – Scenario: Host Sets Equipment ON-LINE
Process
Process State Model
The equipment will support a GEM Process State Model as required by the SEMI E30 standard.
PROCESSING
NOT ACTIVE
11
12
2
6
9
3
PAUSE
C WAITING
4
10
5
7
EXECUTING
ASSIST
8
AUTO RUN
PROCESSING ACTIVE
Figure 20 - K&S Model Power Series Automatic Ball Bonder and K&S Model Gen-S Automatic Ball Bonder
Page - 58 - of 324
Jan 28, 2021 Rev 4.2
Kulicke & Soffa™
SECS/GEM Interface for K&S Ball Bonders
Bonder software version x-xx-x-473-series
Process State Transitions
#
CURRENT
STATE
TRIGGER EVENT
NEW
STATE
Action
1
System initialization
System power-up.
None
2
AUTO RUN
3
AUTO RUN
4
AUTO RUN
PAUSE
None
5
ASSIST
PROCESSING
NOT ACTIVE
None
6
PAUSE
Operator completes job
or a fatal error occurs.
Auto detects an assist
condition.
Operator pressed STOP
button to enter
Sequence Stop.
1) Operator selects Abort
Auto from Assist.
2) Operator selects
Standby Mode.
1) Operator selects Abort
Auto from Sequence
Stop.
2) Operator selects
Standby Mode.
PROCESSING
NOT ACTIVE
PROCESSING
NOT ACTIVE
ASSIST
PROCESSING
NOT ACTIVE
None
COMMENT
None
None
Figure 21 – State Changes for Process Model.
Process States
AUTO RUN ............................... In Auto Mode and RUN button pressed
PAUSE ..................................... In Auto Mode, RUN button pressed and manually entered Sequence Stop by
pressing Stop button from AUTO RUN.
ASSIST ..................................... In Auto Mode, RUN button pressed and an assist occurred.
PROCESSING NOT ACTIVE .... ALL other machine states.
Page - 59 - of 324
Jan 28, 2021 Rev 4.2
Kulicke & Soffa™
SECS/GEM Interface for K&S Ball Bonders
Bonder software version x-xx-x-473-series
4.4
Data Collection
Event Data Collection
COMMENT
Send Multi-block Grant.
HOST
EQUIPMENT
COMMENT
S6,F5
If Event Report is multi-block,
then send a Multi-block Inquire
Message.
S6,F6→
S6,F11
Send Event Report.
Host Acknowledges the Event
S6,F12→
Report.
Figure 22 – Scenario: Collection Event Occurs on the Equipment
Host Requests Collection Event Report
COMMENT
HOST
Host requests a collection event
S6,F15→
report.
EQUIPMENT
COMMENT
S6,F16
Equipment Sends a Collection
Event Report.
Figure 23 – Scenario: Host Requests Collection Event Report
Collection Event Reporting Setup
COMMENT
HOST
If Define Report is Multi-block and
S2,F39→
Multi-block inquire EC is enabled,
then send a Multi-block inquire.
EQUIPMENT
S2,F40
Send the report definitions.
S2,F33→
If Link Event/Report is Multi-Block
and Multi-block Inquire EC is
enabled, then send a Multi-block
inquire.
Link Events to Report.
Multi-block grant.
DATAIDs, RPTIDs and VIDs
received by equipment.
S2,F34
Sent Report Definition
acknowledge.
S2,F40
Multi-Block grant.
S2,F39→
S2,F35→
CEIDs and RPTIDs received by
equipment.
S2,F36
Enable Specific Collection Events.
COMMENT
Event linkages accepted.
Acknowledge = 0
S2,F37→
Enable/Disable CEIDs.
Enable events accepted.
Acknowledge = 0
Figure 24 – Scenario: Collection Event Report Setup
S2,F38
Host Requests Report
COMMENT
Host request data variables
contained in report RPTID.
HOST
S6,F19→
EQUIPMENT
S6,F20
Page - 60 - of 324
Jan 28, 2021 Rev 4.2
Kulicke & Soffa™
COMMENT
Equipment responds with a list of
variable data for the given
RPTID.
SECS/GEM Interface for K&S Ball Bonders
Bonder software version x-xx-x-473-series
Figure 25 – Scenario: Host Requests Report
Equipment Status Report
COMMENT
Host requests report of selected
status variable values.
HOST
S1,F3→
EQUIPMENT
COMMENT
S1,F4
Equipment responds with the
requested status variable data.
Figure 26 – Scenario: Host Requests Equipment Status Report
Equipment Status Variable Namelist Report
COMMENT
Host requests equipment identify
status variables.
HOST
S1,F11→
EQUIPMENT
COMMENT
S1,F12
Equipment responds with the
requested status variable
descriptions.
Figure 27 – Scenario: Host Requests Equipment Status Namelist
4.5
Alarms
Enable/Disable Alarms
COMMENT
Enable/Disable alarm
HOST
S5,F3→
EQUIPMENT
COMMENT
S5,F4
Equipment Acknowledges
Figure 28 – Scenario: Host Enables or Disables Alarm
Upload Alarm Information
COMMENT
Request alarm data/text.
HOST
S5,F5→
EQUIPMENT
COMMENT
S5,F6
Send alarm data / text.
Figure 29 – Scenario: Upload Alarm Information
Alarm Detected By Equipment
COMMENT
Acknowledge.
4.6
HOST
EQUIPMENT
COMMENT
S5,F1
Send Alarm Report if alarm is
enabled.
S5,F2→
Figure 30 – Scenario: Alarm Occurrence Deleted By Equipment
Remote Control
Host Sends Remote Command to Equipment
COMMENT
Host Command Send.
HOST
S2,F41→
EQUIPMENT
S2,F42
COMMENT
Host Command Acknowledge.
Figure 31 – Scenario: Host Sends Remote Command to Equipment
The following RCMDs are recognized by the equipment. Case is not significant, and dashes ‘-‘ may be substituted
for underscores ‘_’.
Note: Equipment will check previous equipment mode to decide accept remote command or not, when it is in
Power Save or Power Restroation mode.
Page - 61 - of 324
Jan 28, 2021 Rev 4.2
Kulicke & Soffa™
SECS/GEM Interface for K&S Ball Bonders
Bonder software version x-xx-x-473-series
Commands
ACCEPT_IN_MAG
ACCEPT_OUT_MAG
CALC_PM_DATA
RCMDs recognized by the equipment
Description
Arguments
Positive response to equipmentRETMAGID – ID of
initiated MHS_IN_BCR_SCAN
the magazine at the
collection event. Host decides that
input position.
the bar code and process program
match, so equipment should process
RETLOTID – ID of
magazine.
the lot for the input
magazine.
Positive response to equipmentRETMAGID – ID of
initiated MHS_OUT_BCR_SCAN
the magazine at the
collection event. Host decides that
output position.
the bar code and process program
match, so equipment should process
RETLOTID – ID of
magazine.
the lot for the output
magazine.
Begin calculations of Production
N/A
Monitoring Data (see SVID’s 3500 –
3541/ 3597 – 3613/ 3618 – 3623/
3626 – 3637). Equipment constants
PM_StartTime and PM_StopTime
must be set via S2 F15 prior to
issuing this remote command.
Equipment will notify host that data
is ready via the collection event
Process Monitoring Data Ready.
ENTER_HIT
Request equipment to enter Host
Initiated Transfer Mode.
N/A
EXIT_HIT
Request equipment to exit Host
Initiated Transfer Mode.
N/A
Page - 62 - of 324
Jan 28, 2021 Rev 4.2
Kulicke & Soffa™
Note
Equipment accepts this
command in any mode
except Motor Stop
Mode. If the
equipment received
the command while in
Auto: Run mode
processing a device,
the equipment
completes processing
the current device, and
suspends device
processing to perform
the calculations of
Production Monitoring
Data. The equipment
resumes device
processing once the
calculation is
completed.
Equipment only
accepts this command
when it is in Idle mode
(i.e. none of the
equipment operational
mode is selected).
SECS/GEM Interface for K&S Ball Bonders
Bonder software version x-xx-x-473-series
Commands
INHIBIT_AUTO
RCMDs recognized by the equipment
Description
Arguments
Prevent the operator from entering
N/A
AUTO: RUN mode.
Page - 63 - of 324
Jan 28, 2021 Rev 4.2
Kulicke & Soffa™
Note
If the equipment is in
AUTO:RUN
processing a device
when this command is
received, the
equipment completes
processing the current
device, returns to
PROCESSING NOT
ACTIVE process state,
and enables Inhibit
Auto: Run mode.
Equipment remains in
Inhibit Auto: Run
mode until the
RELEASE_INHIBIT_
AUTO remote
command is received
or when the equipment
is rebooted.
SECS/GEM Interface for K&S Ball Bonders
Bonder software version x-xx-x-473-series
OS_FILE_DWNLD
Initiates downloading of equipment
Operating Software
N/A
Page - 64 - of 324
Jan 28, 2021 Rev 4.2
Kulicke & Soffa™
1.
When the
bonder receives the
S2F41 (Host
Command Send)
message with a
command parameter
name of
OS_FILE_DWNLD
the command callback
function performs the
following in order:
2.
Check initial
conditions for
accepting or rejecting
the remote command.
3.
Send the
remote command
acknowledge to the
host.
4.
Use Stream
13 messages to request
the PACKAGE.INF
file from the host.
5.
Use the data
in PACKAGE.INF to
check for OS
install/upgrade
requirements.
6.
Notify host if
bonder does or does
not meet the OS
upgrade/installation
requirements. Request
the files needed for OS
upgrade/installation if
bonder meets the
requirements. Upon
completion of file
download, the operator
will be prompted with
an OK/CANCEL
dialog to complete the
software installatio.7.
The
OS_FILE_DWNLD
command will be
rejected if the bonder
operational mode is
not in Idle (i.e. no
operational mode is
selected) or Standby.
8.
The bonder
will include in its reply
to the command
request the appropriate
host command
parameter
SECS/GEM Interface for K&S Ball Bonders
Bonder software version x-xx-x-473-series
Commands
RCMDs recognized by the equipment
Description
Arguments
Prepare Process Program for upload.
Equipment will notify host that
program is ready (or an error
occurred during preparation) via the
collection event PP Upload and the
status variables UploadPPStatus and
UploadPPName.
Load program into memory for
Processing. Equipment will notify
host that program has been
successfully loaded via the collection
event PP Select OK, or that an error
occurred during loading via the
collection event PP Select Failed.
PPID – name of
program to be
uploaded, including
the .BND extension
PROCESS_START
Start Process Remotely
N/A
REJECT_IN_MAG
Negative response to equipmentinitiated MHS_IN_BCR_SCAN
collection event. Host decides that
the bar code and process program
DO NOT match, so equipment
should unload magazine.
RETMAGID – ID of
the magazine at the
input position.
PP_PREP
PP_SELECT
REJECT_OUT_MAG
RELEASE_INHIBIT_AUTO
RESET_PROD_COUNTERS
Negative response to equipmentinitiated MHS_OUT_BCR_SCAN
collection event. Host decides that
the bar code and process program
DO NOT match, so equipment
should unload magazine.
Disables Inhibit Auto: Run mode.
Reset Status Variables Devices
Processed and Devices Skipped to
zero.
PPID – name of
program to be loaded,
including the .BND
extension
RETLOTID – ID of
the lot for the input
magazine.
RETMAGID – ID of
the magazine at the
output position.
RETLOTID – ID of
the lot for the output
magazine.
N/A
N/A
Page - 65 - of 324
Jan 28, 2021 Rev 4.2
Kulicke & Soffa™
Note
acknowledge code
listed below:
2 = Cannot perform
now. Bonder is not in
Idle (i.e. no
operational mode is
selected) or Standby
mode.
4= Acknowledge;
command will be
performed.
N.
Equipment only
accepts this command
when it is in HIT
mode.
Equipment only
accepts this command
when it is in Idle mode
(i.e. none of the
equipment operational
mode is selected).
THE COMMAND
WILL BE REJECTED
IF THE
WORKHOLDER IS
NOT EMPTY.
Need sign safety
agreement, please
contact KNS for more
information
SECS/GEM Interface for K&S Ball Bonders
Bonder software version x-xx-x-473-series
Commands
STOP_PROCESSING
MOVE_TO_IDLE
LTO_ENABLE
LTO_DISABLE
INIT_LOT_SPEC
RCMDs recognized by the equipment
Description
Arguments
Request that the equipment pause
N/A
processing and enter the PAUSED
process state. See section 4.3
Move machine to IDLE mode from
N/A
any mode other than equipment
under below condition:
1.
Equipment in Standby
mode.
2.
Equipment in AUTO:RUN
mode.
3.
Equipment in Heat Block
teach mode.
4.
Operation GUI display
menu or dialog not support mapped
MMI “Esc” hotkey.
5.
Information/Warning/Error
pop-up dialog showing up.
Enable light tower override setting.
N/A
Disable light tower override setting.
N/A
Initialize lot data items.
RETLOTID – Lot ID
Name.
MAG_NUM
– Total Mag Number
in Lot.
Note
Only applicable for
bonder with Mag
Handler
Configuration
SUBSTRAT
E_NUM– Total
Substrate Number in
Lot.
PPID–
Current PPID for this
Lot.
ABORT_LOT
Abort Current Lot and set to InActive Mode.
START_LOT
Start Current Lot and set to In-Active
Mode.
LOTOPID–
Current Operator ID
for this Lot.
N/A
N/A
Page - 66 - of 324
Jan 28, 2021 Rev 4.2
Kulicke & Soffa™
Only applicable for
bonder with Mag
Handler
Configuration
Only applicable for
bonder with Mag
Handler
Configuration
SECS/GEM Interface for K&S Ball Bonders
Bonder software version x-xx-x-473-series
Commands
JOG_EJECT_MAG
RCMDs recognized by the equipment
Description
Arguments
DO_MAG_CMD-remote magazine
The DO_MAG_CMD
operation CMD.
has six values.
I.
0JOG_IP
UT_MA
G means
mhs to
jog input
mag.
II.
1BJOG_I
PUT_M
AG
means
mhs to
jog input
mag
reversel
y.
III.
2JOG_OP
UT_MA
G means
mhs to
jog
output
mag.
IV.
3BJOG_
OPUT_
MAG
means
mhs to
jog
output
mag
reversel
y.
V.
4EJE_IP
UT_MA
G means
mhs to
eject
input
mag.
VI.
5EJE_OP
UT_MA
G means
mhs to
eject
output
mag.
Page - 67 - of 324
Jan 28, 2021 Rev 4.2
Kulicke & Soffa™
Note
SECS/GEM Interface for K&S Ball Bonders
Bonder software version x-xx-x-473-series
Commands
LF_IN_OUT
LOAD_MGZ_CONFIRM
CLEAR_MAG_ASSIST
MAG_ID_SCAN_ACK
RCMDs recognized by the equipment
Description
Arguments
The LF_CMD has two values.
DO_LF_CMD –
LF_PULL_IN means mhs to pull in a remote lead frame
new lead frame. LF_EJECT_OUT
operation CMD.
means mhs to eject the lead frame.
The
DO_LF_CMD has
two values.
LF_PULL_IN means
mhs to pull in a new
lead frame.
LF_EJECT_OUT
means mhs to eject
the lead frame.
Load magazine confirmation
MGZ-ID and
CONFIRM-FLAG.
CONFIRM-FLAG
has three
options:T,F,H
Clear Magazine Assist
N/A
Magazine ID Scan Acknowledge
MAGTYPE, ACK
and MAGID
MAGTYPE has two
options: INPUT and
OUTPUT.
ACK has three
options: TRUE,
FALSE and WAIT
MAG_EJECT_HOST_VALI
DATION
Magazine Eject Host Validation
One argument
MAGTYPE, which
has two options,
INPUT and
OUTPUT.
Another argument
ACK which has two
options, GO and
NOGO.
N/A
RESET_PBI_STATS
Reset the PBI statistics
DO_INDEX
SUB_CONFIRM
Do index
Sub Confirm
STOP
RESET_STATS_SUMMAR
Y
RESET_TOOL_COUNTER
RESET_WIRE_SPOOL
Stop
Remote reset statistics summary
N/A
SUB-ID and
CONFIRM-FLAG.
CONFIRM-FLAG
has two options: T,F.
N/A
N/A
Remote reset tool counter
Remote reset wire spool
N/A
N/A
Page - 68 - of 324
Jan 28, 2021 Rev 4.2
Kulicke & Soffa™
Note
Equipment only
accepts this command
when it is not
initializing or and PBI
status GUI is not
active
SECS/GEM Interface for K&S Ball Bonders
Bonder software version x-xx-x-473-series
Commands
COMPRESS_FILE
INSPECTION_CONFIRM
INSPECTION_PARA_INFO
_SEND
RCMDs recognized by the equipment
Description
Arguments
Remote compress file or folder
One argument
FUNCTION –
compress file function
type.
FUNCTION has one
option:
REAL_TIME_3RD_
OPT_IMAGES– real
time 3RD optical
inspection image file.
LHM: Confirm inspection result
SUB-ID and
CONFIRM-FLAG.
CONFIRM-FLAG
has two options: T
and F.
LHM: Send inspection parameters.
PARAM_COUNT
PARAM_CD_1,
SAMPLE_QTY_1,
USL_1,LSL_1,
UCL_1, LCL_1,
PARAM_CD_2,
LOAD_MGZ_LOT_CONFI
RM
Get lot id information.
RETRIEVE_CURRPP_LAS
TSAVED_TS
Retrieve the last saved time stamp
based on current active loaded
process program
PART_PROCESSED_RSLT
_CONFIRM
Perform part processed result
validation
Three arguments
MAGTYPE, ACK
and LOTID.
MAGTYPE has two
options: INPUT and
OUTPUT. ACK has
one option: TRUE.
PP_SOURCE
( 0 means PP in Disk;
1 means PP in RAM;
2 means PP in RAM
and Disk)
2 arguments
1.
“ACK”
Accept/reject
“0”: accept result
Others: reject result
2.
“REASON”
Detail reason.
Page - 69 - of 324
Jan 28, 2021 Rev 4.2
Kulicke & Soffa™
Note
Applicable for specific
customer only. Please
contact K&S for more
information.
Parameters will be
applied to Loop ID
(ECID 1751). It’s
recommended to
always set the Loop ID
right before sending
this RCMD.
Applicable for specific
customer only. Please
contact K&S for more
information.
Applicable for specific
customer only. Please
contact K&S for more
information.
Applicable for specific
customer only. Please
contact K&S for more
information.
Applicable for specific
customer only. Please
contact K&S for more
information.
SECS/GEM Interface for K&S Ball Bonders
Bonder software version x-xx-x-473-series
Commands
CHANGE_OVER_REQUES
T
TOOL_CHANGE_CONFIR
M
WIRE_CHANGE_CONFIR
M
RCMDs recognized by the equipment
Description
Arguments
Request to start change over
5 arguments
1.
“CONFIRMFLAG”
Accept/reject
“T”: accept
changeover
“F”: reject
changeover
Others: Invalid Value
2.
“PARTSPER-CARRIER”
Index Count
3.
“PROGNAME”
For productset up
4.
“TOOLFAMILY”
For productset up
5.
“WIREPART-NO”
For productset up
Request to tool change
5 arguments
1.
“ACK”
Accept/reject
“0”: accept
Others: reject
2.
“TOOL-ID”
3.
“TOOLSTATE”
“0”: OK
“1”: Warning
“2”: Block
4.
“TOOLFAMILY”
5.
“COUNTER
”
Tool remaining
counter
Request to wire spool change
4 arguments
1.
“ACK”
Accept/reject
“0”: accept
Others: reject
2.
“WIRE-ID”
3.
“WIRESTATE”
“0”: OK
“1”: Warning
“2”: Block
4.
“WIREPART-NO”
Page - 70 - of 324
Jan 28, 2021 Rev 4.2
Kulicke & Soffa™
Note
Applicable for specific
customer only. Please
contact K&S for more
information.
Applicable for specific
customer only. Please
contact K&S for more
information
Applicable for specific
customer only. Please
contact K&S for more
information
SECS/GEM Interface for K&S Ball Bonders
Bonder software version x-xx-x-473-series
Commands
RESET_PBI_WIRE_INSP_S
TATS
4.7
RCMDs recognized by the equipment
Description
Arguments
Wire Inspection: Reset wire
inspection statistics
Note
Applicable for specific
customer only. Please
contact K&S for more
information.
Equipment Constants
Host Sends Equipment Constants
COMMENT
Host sends equipment constants.
HOST
S2,F15→
EQUIPMENT
COMMENT
S2,F16
Equipment sets constants.
Figure 32 – Scenario: Host Sends New Equipment Constant Value to the Host
Host Equipment Constants Request
COMMENT
Host constant request.
HOST
S2,F13→
EQUIPMENT
COMMENT
S2,F14
Equipment constant data.
Figure 33 – Scenario: Host Request Equipment Constant Value from Equipment
Host Equipment Constants Namelist Request
COMMENT
Host constant namelist request.
HOST
S2,F29→
EQUIPMENT
COMMENT
S2,F30
Equipment constant namelist.
Figure 34 – Scenario: Host Requests Equipment Constants Namelist
4.8
Process Programs
The equipment supports uploads or downloads only of unformatted process programs.
Process Program Deletion By Host
COMMENT
Delete Process Program Send.
HOST
S7,F17→
EQUIPMENT
COMMENT
Equipment must be in HIT mode.
S7,F18
Delete Process Program
acknowledge.
Figure 35 – Scenario: Host Requests Deletion of Process Program
Host-Initiated Process Program Upload (Unformatted)
Page - 71 - of 324
Jan 28, 2021 Rev 4.2
Kulicke & Soffa™
SECS/GEM Interface for K&S Ball Bonders
Bonder software version x-xx-x-473-series
COMMENT
Process Program Request.
HOST
S7,F5→
EQUIPMENT
S7,F6
COMMENT
Equipment responds with a zero
length list.
If in HIT mode, the Equipment
prepares the process program
for uploading by combining
component files into a single zip
file, else jump to end.
S6,F11
Process Program Request.
Equipment notifies host that
process program is ready for
uploading.
S7,F5→
S7,F6
Process Program Data.
Figure 36 – Scenario: Host Initiated Process Program Upload.
Page - 72 - of 324
Jan 28, 2021 Rev 4.2
Kulicke & Soffa™
SECS/GEM Interface for K&S Ball Bonders
Bonder software version x-xx-x-473-series
COMMENT
Remote Command PP_PREP.
HOST
S2,F41→
EQUIPMENT
S2,F42
S6,F11
Process Program Request.
COMMENT
PPID specified as argument.
If in HIT mode, equipment
acknowledges command, else
reject and jump to end.
Equipment prepares the process
program and notifies the host
that the program is ready for
uploading.
S7,F5→
S7,F6
Process Program Data.
Figure 37 – Scenario: Host Initiated PP Upload using PP_PREP remote command.
When the equipment receives an S7,F5 Process Program Request (PPR) message, it replies with a S7,F6 Process
Program Data (PPD) message. If the equipment is 1) not in Host Initiated Transfer (HIT) mode or 2) is unable to
upload the requested process program or, 3) the program has not been prepared for upload but the control context
is HIT, then the equipment will send the S7,F6 Process Program Data (PPD) message with a zero-length list. In case
3) above, the equipment will proceed to combine the process program components into a single file and notify the
host with a S6,F11 at completion of the preparation for upload. On receiving the S6,F11, the host can repeat the
upload request and the process program will be sent.
The remote command PP_PREP, with the PPID specified, prompts the equipment to prepare the process program
for upload, with the S6,F11 sent by the equipment (if the equipment is in HIT mode) at the completion of the
preparation for upload. The host can then send the S7,F5 and expect an immediate S7,F6 response (if the equipment
remains in HIT mode).
Equipment-Initiated Process Program Download (Unformatted)
COMMENT
HOST
EQUIPMENT
COMMENT
S7,F5
Process Program Request
Process Program Data
S7,F6→
Figure 38 – Scenario: Equipment Initiated Process Program Download
Process Program Directory Request
COMMENT
Current EPPD Request.
HOST
S7,F19→
EQUIPMENT
COMMENT
Equipment must be in HIT mode.
S7,F20
Current EPPD Data.
Figure 39 – Scenario: Process Program Directory Request
The host can determine which process programs exist on the equipment. When the equipment receives an S7,F19
Current EPPD Request (RER) message from the host, it replies with an S7,F20 Current EPPD Data (RED) message.
If the equipment accepts the S7,F19 Current EPPD Request (RER) message, then an S7,F20 Current EPPD Data
(RED) message containing a list of the process programs stored at the equipment will be returned. If the message is
rejected, then the S7,F20 Current EPPD Data (RED) message will contain a zero-length list.
Host-Initiated Process Program Download (Unformatted)
Page - 73 - of 324
Jan 28, 2021 Rev 4.2
Kulicke & Soffa™
SECS/GEM Interface for K&S Ball Bonders
Bonder software version x-xx-x-473-series
COMMENT
If process program is multi-block
and
DisableProcessProgramLoadIn
quire is false, then send Process
Program Load Inquire. Specify
exact filename and file size in
bytes.
HOST
S7,F1→
EQUIPMENT
S7,F2
Process Program Send.
COMMENT
Equipment must be in HIT mode.
Process Program Load Grant
S7,F3→
S7,F4
S6,F11
Process Program Acknowledge.
Equipment sends an event report
to host
Figure 40 – Scenario: Host-Initiated Process Program Download.
If the host is attempting to download a multi-block process program to the equipment, then an S7,F1 Process Program
Load Inquire (PPI) and S7,F2 Process Program Load Grant (PPG) transaction must precede the process program
download. When the equipment receives an S7,F1 message from the host, the equipment will respond with an S7,F2
PPGNT.
If the download is granted by the equipment, the host can send the S7,F3 Process Program Send (PPS) message
containing the unformatted process program. The equipment will respond with an S7,F4 ACKC7.
Once the equipment has verified the downloaded program, the results of the verification will be stored in the status
variable DownloadPPStatus, and the collection event PP Download will be sent to the host.
Equipment-Initiated Process Program Upload (Unformatted)
COMMENT
HOST
Process Program Load Grant.
EQUIPMENT
COMMENT
S7,F1
If the process program is multiblock and
DisableProcessProgramLoadIn
quire is false, then send Process
Program Load Inquire.
S7,F2→
S7,F3
Process Program Send.
Process Program Acknowledge.
S7,F4→
Figure 41 – Scenario: Equipment-Initiated Process Program Upload - Unformatted
4.9
Terminal Services
The equipment terminal services will allow for the host to display information on the equipment’s display devices.
Host Sends Information to Equipment’s Display Device
COMMENT
Host sends textual information to
equipment for display to operator
at terminal x.
HOST
S10,F3→
EQUIPMENT
COMMENT
S10, F4
Equipment acknowledges
request to display text.
Figure 42 – Scenario: Host Sends Information to Equipment’s Display Device
There are three types terminal message.
Single-Type Terminal Message (TID = 0, 1, 2, 3).
❖ 0 = Standard message
❖ 1 = Message immediate display
❖ 2 = Message immediate display - dialog box has colored label
❖ 3 = Message immediate display - dialog box has colored label, Alarm/beep, Light tower blinks Yellow
Persistent-Type Terminal Message (TID =10, 11, 12, 13). It would be hold until a new message arrives to
overwrite it.
Page - 74 - of 324
Jan 28, 2021 Rev 4.2
Kulicke & Soffa™
SECS/GEM Interface for K&S Ball Bonders
Bonder software version x-xx-x-473-series
❖ 10 = Standard message
❖ 11 = Message immediate display
❖ 12 = Message immediate display - dialog box has colored label
❖ 13 = Message immediate display - dialog box has colored label, Alarm/beep, Light tower blinks Yellow.
Multiple-Type Terminal Messages (TID = 20, 21, 22, 23). Equipment maintains a message buffer to hold on
message. Equipment will reject coming message (ACKC10 = 1 - Message will not be displayed) if the maximum
number of buffered message is reached. In the equipment GUI, user could be able to view the previous and next
message, and delete any one he wants.
❖ 20 = Standard message
❖ 21 = Message immediate display
❖ 22 = Message immediate display - dialog box has colored label
23 = Done Disabled; Message immediate display - dialog box has colored label, Alarm/beep, Light tower blinks Yellow.
Host Sends Multi-block Message to Equipment’s Display Device
COMMENT
Host sends textual information to
equipment for display to operator
at terminal x.
HOST
S10,F5→
EQUIPMENT
COMMENT
S10, F6
Equipment acknowledges
request to display text.
Figure 43 – Scenario: Host Sends Multi-block Message to Equipment Display
Operator Sends Information to Host
COMMENT
Operator sends textual
information via equipment
terminal x.
EQUIPMENT
S10,F1→
HOST
S10, F2
Page - 75 - of 324
Jan 28, 2021 Rev 4.2
Kulicke & Soffa™
COMMENT
Host acknowledges receipt of
operator imitated message.
SECS/GEM Interface for K&S Ball Bonders
Bonder software version x-xx-x-473-series
4.10
Strip Map
The equipment supports stream 14 messages as defined by the SEMI E30 standard. (Premium Option)
Strip Map standard implementation shall use the SECS/GEM standard Object Services (S14, F1/F2) and standard
Collection Event S6, F11/F12 Streams and Functions for the transfer of Strip Maps to and from equipment.
Get Strip Map Attribute Data
The equipment requests a strip map download from the host using the Standard Object Services (OSS) command,
S14, F1 GetAttribute Request (GAR). The host will respond to the GetAttribute Request with an S14F2, Get
Attribute Data (GAD).
COMMENT
EQUIPMENT
HOST
COMMENT
Equipment sends a message with
S14,F1→
OBJSPEC(KNS), OBJTYPE(Strip
Map), OBJID(StripID) and
ATTRID(Rows/Columns/OriginLo
cation/LotID/CellStatus).
S14, F2
Host acknowledges requested
data with corresponding OBJID
data items and desired OBJACK.
S14,F1 Sample Message
Page - 76 - of 324
Jan 28, 2021 Rev 4.2
Kulicke & Soffa™
SECS/GEM Interface for K&S Ball Bonders
Bonder software version x-xx-x-473-series
Item
GUI Configuration
Map Data Request
Message S14F1
Page - 77 - of 324
Jan 28, 2021 Rev 4.2
Kulicke & Soffa™
Map Data Reply
Message S14F2
SECS/GEM Interface for K&S Ball Bonders
Bonder software version x-xx-x-473-series
1
Cell Status Only
S14F1 (WB)
---<L [5]
------<A [3]
KNS>
------<A [8]
StripMap>
------<L [1]
---------<A [7]
StripID>
------>
------<L [0]>
------<L [5]
---------<A [4]
Rows>
---------<A
[7]
Columns>
---------<A
[14] OriginLocation>
---------<A [5]
LotID>
---------<A
[10] CellStatus>
------>
--->
Page - 78 - of 324
Jan 28, 2021 Rev 4.2
Kulicke & Soffa™
S14F2 (Host)
< L,2
< L,1
< L,2
< A[11]
'tempStripID'>
< L,5
< L,2
<
A[4]
'Rows'>
<
U4
1>
>
< L,2
<
A[7]
'Columns'>
<
U4
5>
>
< L,2
<
A[14]
'OriginLocatio
n'>
<
U1
1>
>
< L,2
<
A[5]
'LotID'>
<
A[9]
'TestLotID'>
>
< L,2
<
A[10]
'CellStatus'>
< L,5
<
U1
0>
<
U1
0>
<
U1
0>
<
U1
0>
<
U1
0>
>
>
>
>
>
< L,2
< U1
0>
< L,0
>
>
>
SECS/GEM Interface for K&S Ball Bonders
Bonder software version x-xx-x-473-series
2
Cell Grade Only
S14F1 (WB)
---<L [5]
------<A [3]
KNS>
------<A [8]
StripMap>
------<L [1]
---------<A [7]
StripID>
------>
------<L [0]>
------<L [5]
---------<A [4]
Rows>
---------<A
[7]
Columns>
---------<A
[14] OriginLocation>
---------<A [5]
LotID>
---------<A
[9]
CellGrade>
------>
--->
Page - 79 - of 324
Jan 28, 2021 Rev 4.2
Kulicke & Soffa™
S14F2 (Host)
< L,2
< L,1
< L,2
< A[11]
'tempStripID'>
< L,5
< L,2
<
A[4]
'Rows'>
<
U4
1>
>
< L,2
<
A[7]
'Columns'>
<
U4
5>
>
< L,2
<
A[14]
'OriginLocatio
n'>
<
U1
1>
>
< L,2
<
A[5]
'LotID'>
<
A[9]
'TestLotID'>
>
< L,2
<
A[10]
'CellGrade'>
< L,5
<
U1
11>
<
U1
11>
<
U1
11>
<
U1
11>
<
U1
11>
>
>
>
>
>
< L,2
< U1
0>
< L,0
>
>
>
SECS/GEM Interface for K&S Ball Bonders
Bonder software version x-xx-x-473-series
3
Cell Status & Cell Grade
S14F1 (WB)
---<L [5]
------<A [3]
KNS>
------<A [8]
StripMap>
------<L [1]
---------<A [7]
StripID>
------>
------<L [0]>
------<L [6]
---------<A [4]
Rows>
---------<A
[7]
Columns>
---------<A
[14] OriginLocation>
---------<A [5]
LotID>
---------<A
[10] CellStatus>
---------<A
[9]
CellGrade>
------>
--->
Page - 80 - of 324
Jan 28, 2021 Rev 4.2
Kulicke & Soffa™
S14F2 (Host)
< L,2
< L,1
< L,2
<
A[7] 'StripID'>
< L,6
< L,2
<
A[4]
'Rows'>
<
U4
1>
>
< L,2
<
A[7]
'Columns'>
<
U4
5>
>
< L,2
<
A[14]
'OriginLocatio
n'>
<
U1
1>
>
< L,2
<
A[5]
'LotID'>
<
A[3]
'abc'>
>
< L,2
<
A[10]
'CellStatus'>
< L,5
<
U1
2>
<
U1
2>
<
U1
2>
<
U1
2>
<
U1
2>
>
>
< L,2
<
A[9]
'CellGrade'>
< L,5
<
U1
11>
<
U1
11>
SECS/GEM Interface for K&S Ball Bonders
Bonder software version x-xx-x-473-series
<
U1
11>
U1
11>
U1
11>
<
<
>
>
>
>
>
< L,2
< U1
< L,0
>
>
>
S14,F2 Sample Message
Page - 81 - of 324
Jan 28, 2021 Rev 4.2
Kulicke & Soffa™
0>
SECS/GEM Interface for K&S Ball Bonders
Bonder software version x-xx-x-473-series
Item
1
OBJACK Setting
OBJACK = 0
Map Data Reply Message S14F2
< L,2
< L,1
< L,2
< A[7] 'StripID'>
< L,6
< L,2
< A[4]
'Rows'>
< U4
1>
>
< L,2
< A[7]
'Columns'>
< U4
5>
>
< L,2
< A[14]
'OriginLocation'>
< U1
1>
>
< L,2
< A[5]
'LotID'>
< A[3]
'abc'>
>
< L,2
< A[10]
'CellStatus'>
< L,5
< U1
2>
< U1
2>
< U1
2>
< U1
2>
< U1
2>
>
>
< L,2
< A[9]
'CellGrade'>
< L,5
< U1
11>
< U1
11>
< U1
11>
< U1
11>
< U1
11>
>
>
>
>
>
< L,2
< U1
0>
< L,1
< L,2
< U2 0>
< A[0]
''>
>
>
>
>
Page - 82 - of 324
Jan 28, 2021 Rev 4.2
Kulicke & Soffa™
SECS/GEM Interface for K&S Ball Bonders
Bonder software version x-xx-x-473-series
2
OBJACK = 1
Host wants to reject a particular substrate and
wants bonder to prompt Error#2250
STRIP_MAP_HOST_REPLY_ERROR
Note:
ERRCODE, ERRTEXT can be leave as
empty
< L,2
< L,1
< L,2
< A[11] 'tempStripID'>
< L,6
< L,2
< A[4]
'Rows'>
< U4
1>
>
< L,2
< A[7]
'Columns'>
< U4
5>
>
< L,2
< A[14]
'OriginLocation'>
< U1
1>
>
< L,2
< A[5]
'LotID'>
< A[3]
'abc'>
>
< L,2
< A[10]
'CellStatus'>
< L,5
< U1
0>
< U1
0>
< U1
0>
< U1
0>
< U1
0>
>
>
< L,2
< A[9]
'CellGrade'>
< L,5
< U1
11>
< U1
11>
< U1
11>
< U1
11>
< U1
11>
>
>
>
>
>
< L,2
< U1
1>
< L,1
< L,2
< U2 0>
< A[0]
''>
>
>
>
>
Query Cell Status/Cell Grade Data
Page - 83 - of 324
Jan 28, 2021 Rev 4.2
Kulicke & Soffa™
SECS/GEM Interface for K&S Ball Bonders
Bonder software version x-xx-x-473-series
Strip Map data upload can be retrieved either via S6F11 report or SVID inqury stream S1F3/F4.
COMMENT
EQUIPMENT
HOST
COMMENT
Once cell status/cell grade
S6,F11→
variables updated, equipment
sends CEID 8336.
S1, F3
Host receives the event and
query corresponding cell
status/cell grade data.
Equipment sends the data to host.
4.11
S1, F4→
Host receives the queried data.
Job Control
The equipment supports stream function as defined by the SEMI E5 (Equipment Communications Standard), E87
(carrier management), E40 (Processing management), and E94 (control job management) to realize production
automation control by factory host. (Premium Option)
S3F17/S3F18 Stream Function
S3F17/S3F18 – carrier action request
Page - 84 - of 324
Jan 28, 2021 Rev 4.2
Kulicke & Soffa™
SECS/GEM Interface for K&S Ball Bonders
Bonder software version x-xx-x-473-series
Data
DATAID
CARRIERACTION
Description
Data ID
Specifies the action requested for a carrier
CARRIERID
The identifier of a carrier
PORT
Port ID
Capacity
Maximum number of substrates a carrier
can hold
SubstrateCount
The number of substrates currently in the
carrier
Usage
The type of material contained in the
carrier
Ordered list of slot status as provided by
host and corresponding to slot 1,2,3…n
until a successful slot map read, then as
read by equipment.
SlotMap
UNDEFINED – 0
EMPTY – 1
NOT EMPTY – 2
CORRECTLY OCCUPIED – 3
DOUBLESLOTTED – 4
CROSS SLOTTED – 5
ContentMap
Ordered list of a lot and substrate
identifiers corresponding to slot 1,2,3,…n
Remark
will not use this data
Only support
Bind,
ProceedWithCarrier(for
ID
verification),
CancelCarrier
Use it to do CarrierID
Verification.
Only support 1 for input
loadport and 4 for output
loadport, other numbers
are invalid
Will use it to check
whether
SlotMap/ContentMap
count is right or not
Will use it to check
whether presence data
in slotmap is right or not
Will not use
Due
to
hardware
limitation,
slotmap
verification will not be
performed. But will use
this slotmap to check
whether need to pull in
L/F from the slot. So
provided carrier slot
status must match the
slotmap.
Otherwise
incorrect error info will
be
reported
when
pulling L/F.
Will only use substrate
id
when
substrate
verification
after
substrate id scan.
S14F9/S14F10 Stream Function
S14F9/S14F10 – create control job request
Per semi e94, the process jobs specified for a control job must exist prior to calling create control job.
Otherwise, bonder will report fail for this create control job request.
Page - 85 - of 324
Jan 28, 2021 Rev 4.2
Kulicke & Soffa™
SECS/GEM Interface for K&S Ball Bonders
Bonder software version x-xx-x-473-series
Data
OBJSPEC
Description
A text string that has an internal
format and that is used to point to
a specific object instance.
Identifier for a group or class of
objects
OBJTYPE
(Must be ControlJob)
ATTRID
(Identifier
for
an
attribute
for
a
specific
type
of
object)
ObjID
Host defined identifier of the
control job
ProcessingCtrlSpec
Define the method for the order in
which process jobs are initiated
A list of carrierID for material that
will be used by ControlJob.
CarrierInputSpec
MtrlOutSpec
Maps material from source to
destination after processing.
ProcessOrderMgmt
Define the method for the order in
which process jobs are initiated.
StartMethod
A logical flag that determines if
the
ControlJob
can
start
automatically.
Remark
Will not use this
data.
This must be set as
ControlJob
to
indicate
this
is
control job creation
Will use this attribute
data as control job
id, this data is
required.
Only
support
1
process job.
Only one CarrierID
is supported. And
the carrierID must
equal
to
the
CarrierInputSpec in
process
job
definition of above
ProcessingCtrlSpec.
Will not use this
data. Follows the PP
definition. And must
fill in L,0 for this
attribute
Will only support
1=ARRIVAL,
process jobs shall
be initiated as the
related
material
arrives and passes
verification.
Can only support
TRUE – Auto, which
means
when
material
comes,
bonder will start
control job.
S16F15/S16F16 Stream Function
S16F15/S16F16 – create multiple process job request
Currently ball bonder only supports one process job to be queued and one process job to be executed.
So only one process job can be created with this request to queue the process job.
Data
DATAID
PRJOBID
Description
Data ID
Text string which uniquely identifies a
process job
MF
Material format code 1 byte by Format
10.
Page - 86 - of 324
Jan 28, 2021 Rev 4.2
Kulicke & Soffa™
Remark
Will not use this data.
Will use this data.
When bonder sends
process job state
change to host, this
data is required
Only support
value=13 (Quantities
SECS/GEM Interface for K&S Ball Bonders
Bonder software version x-xx-x-473-series
CARRIERID
The identifier of a carrier.
SLOTID
Used to reference material by slot in a
carrier.
Indicates the recipe specification type,
whether tuning is applied and which
method is used.
Recipe specifier. The object specifier of
a recipe.
PRRECIPEMETHOD
RCPSPEC
RCPPARNM
The name of a recipe variable parameter
RCPPARVAL
The initial setting assigned to a recipe
variable parameter.
PRPROCESSSTART
Indicates that the process resource start
processing immediately when ready.
PRPAUSEEVENT
The list of event identifiers which may be
sent as an attribute value to a process
job. When a process job encounter one
of these events it will pause, until it
receives the PRJobCommand RESUME.
Page - 87 - of 324
Jan 28, 2021 Rev 4.2
Kulicke & Soffa™
in carriers) according
to customer provided
example.
Will use this data to
know whether the
material using this
process job.
Will not use. 1,2,….n
as slot sequence.
Only support value=1
recipe only
PP name. Will use it
since process job
status update need
this info.
Will not use now since
we do not support
parameter tuning now
Will not use now since
we do not support
parameter tuning now
Only support
TRUE=AutoStart as
customer provided
flow.
Will not use now.
SECS/GEM Interface for K&S Ball Bonders
Bonder software version x-xx-x-473-series
S16F21/S16F22 Stream Function
S16F21/S16F22 – Get the number of process jobs bonder has space to create
Data
Description
Remark
PRJOBSPACE(ACK)
The number of process jobs that can be If no process job in the
created.
queue, returns 1 to
host.
Otherwise
returns 0 to host.
S16F27/S16F28 Stream Function
S16F27/S16F28 – Control Job Command Request / Control Job Command Acknowledge
Data
Description
Remark
CTLJOBID
Identifier for Control Job. Conforms to Use this data to check
OBJID
which control job is
required
to
be
processed.
CTLJOBCMD
Control Job Command codes are Only
support
assigned as follows.
7=CJAbort now to
1 = CJStart
abort queued control
2 = CJPause
job or active control
3 = CJResume
job
4 = CJCancel
5 = CJDeselect
6 = CJStop
7 = CJAbort
8 = CJHOQ
CPNAME
Command Parameter Name
Since only CJAbort is
supported, it needs fill
CPNAME as “Action”.
CPVAL
Command Parameter Value
It indicates value of
“Action”.
SAVEJOBS(=0) and
REMOVEJOBS(=1)
are supported. It only
affects process jobs
that are in QUEUED
state.
S16F5/S16F6 Stream Function
S16F5/S16F6 – Process Job Command Request/Acknowledge
Page - 88 - of 324
Jan 28, 2021 Rev 4.2
Kulicke & Soffa™
SECS/GEM Interface for K&S Ball Bonders
Bonder software version x-xx-x-473-series
4.12
Calibration Result Data
Object service standard provide an easy and flexible approach to get a collection of data. Each calibration result is
a collection of sub calibration data.
Get Calibration Data
Host could retrieve calibration results through S14F1.With empty the attribute filter; they can retrieve certain
calibration result through setting the OBJID. If not specified OBJID, they will get all calibration results.
Page - 89 - of 324
Jan 28, 2021 Rev 4.2
Kulicke & Soffa™
SECS/GEM Interface for K&S Ball Bonders
Bonder software version x-xx-x-473-series
COMMENT
Host sends a message with
OBJSPEC(KNS),
OBJTYPE(CalibrationResults),
OBJID(Corresponding to
calibration name) and
ATTRID(CalStatus/CalTime/
CalData).
EQUIPMENT
S14,F1→
HOST
S14, F2
COMMENT
Equipment acknowledges
requested data with
corresponding OBJID data items
and desired OBJACK.
Calibration Results Object Attribute Table
Attribute Name
OBJID
OBJTYPE
CalStatus
CalTime
CalData
Definition
Type
Corresponding to calibration
name, refer to Table 4-2
Object type.
Calibration status
text
SECSGEM
Type
ASCII
text
enumerated
ASCII
U2
Calibration time
Calibration data of certain
calibration
text
list
ASCII
List
Page - 90 - of 324
Jan 28, 2021 Rev 4.2
Kulicke & Soffa™
Value
“CalibrationResults”
UNKNOWN - not yet
done (0)
OK - done(1),
NOT GOOD- done(2),
DEFAULT-(3)
SECS/GEM Interface for K&S Ball Bonders
Bonder software version x-xx-x-473-series
Calibration Name and OBJID Mapping
Calibration Name
OBJID
Servo Tune X Axis Calibration
CAL_SERVO_X_FF
Servo Tune Y Axis Calibration
CAL_SERVO_Y_FF
Servo_z_ff Calibration
CAL_SERVO_Z_FF
Servo_z_fb Calibration
CAL_SERVO_Z_FB
PRS Calibration
CAL_PRS
Cross-Hair Offset
CAL_XHAIR_OFFSET
Wand Height Calibration
CAL_WAND_HT
Copper Wand Calibration
CAL_COPPER_WAND_HT
USG Calibration
CAL_USG
Bond Force Calibration
CAL_BOND_FORCE
MHS Rail Z Calibration
CAL_RAIL_Z
Puller Sensor Calibration
CAL_ATX3_PULLER_HALL_SNS
Indexer Gripper Sensor Calibration
CAL_ATX3_INDEX_HALL_SNS
Index Gripping Force Calibration
CAL_ATX3_INDEX_CLG_FORCE
Eject Gripper Sensor Calibration
CAL_ATX3_EJECT_HALL_SNS
Eject Gripping Force Calibration
CAL_ATX3_EJECT_CLG_FORCE
Indexer Calibration
CAL_INDEXER
MHS Xsensor Calibration
CAL_XSENSOR
Input Wall Sensor Calibration
CAL_IN_WALL
Output Wall Sensor Calibration
CAL_OUT_WALL
MHS Rail Calibration
CAL_RAIL
MHS Clamp Calibration
CAL_CLAMP
Input Tray Calibration
CAL_INTRAY
Output Tray Calibration
CAL_OUTTRAY
Input Slot Calibration
CAL_INSLOT
Output Slot Calibration
CAL_OUTSLOT
Y Sensor Offset Calibration
CAL_Y_SENSOR_OFFSET
Temperature Control
CAL_TEMPCONTB1
Jam Detect Calibration
CAL_JDC
CAL JDC Sample:
Page - 91 - of 324
Jan 28, 2021 Rev 4.2
Kulicke & Soffa™
SECS/GEM Interface for K&S Ball Bonders
Bonder software version x-xx-x-473-series
Content of Attribute “CalData”
“CalData” is a set of calibration data items. Each calibration data item composed of name and value.
L, n
# n = number of calibration data items
1. L, 2
1. <name>
2. <value>
.
.
n. L, 2
1. <name>
2. <value>
The following tables list the calibration data items of each calibration. You can get the name, the value type and
description of them.
Page - 92 - of 324
Jan 28, 2021 Rev 4.2
Kulicke & Soffa™
SECS/GEM Interface for K&S Ball Bonders
Bonder software version x-xx-x-473-series
4.13
Error Messages
The equipment supports stream 9 messages as required by the SEMI E30 standard.
Message Fault Due to Unrecognized Device ID
COMMENT
Host sends a message with a
device ID not recognized by the
equipment.
HOST
Sx,Fy→
EQUIPMENT
COMMENT
S9,F1
Equipment reports to the host
that an unrecognized device ID
was received.
Figure 44 – Scenario: Message Fault Due to Unrecognized Device ID
Message Fault Due to Unrecognized Stream Type
COMMENT
Host sends a message containing
a stream type not recognized by
the equipment.
HOST
Sx,Fy→
EQUIPMENT
COMMENT
S9,F3
Equipment reports to the host
that an unrecognized stream
type was received.
Figure 45 – Scenario: Message Fault Due to Unrecognized Stream Type
Message Fault Due to Unrecognized Function Type
COMMENT
Host sends a message containing
a function type not recognized by
the equipment.
HOST
Sx,Fy→
EQUIPMENT
COMMENT
S9,F5
Equipment reports to the host
that an unrecognized function
type was received.
Figure 46 – Scenario: Message Fault Due to Unrecognized Function Type
Message Fault Due to Illegal Data Format
COMMENT
Host sends an incorrectly
formatted message to the
equipment.
HOST
Sx,Fy→
EQUIPMENT
COMMENT
S9,F7
Equipment reports to the host
that a message was received
containing an illegal data format.
Figure 47 – Scenario: Message Fault Due to Illegal Data Format
Message Fault Due to Transaction Timer Timeout
COMMENT
HOST
EQUIPMENT
COMMENT
Sx,Fy
Equipment sends a primary
message requiring a reply to the
host. Reply is not received within
the configured period;
transaction timer timeout occurs.
S9,F9
Equipment reports a transaction
timer timeout.
Figure 48 – Scenario: Message Fault Due to Transaction Timer Timeout
Page - 93 - of 324
Jan 28, 2021 Rev 4.2
Kulicke & Soffa™
SECS/GEM Interface for K&S Ball Bonders
Bonder software version x-xx-x-473-series
4.14
Spooling
The equipment will support the GEM Spool State Model as described by the SEMI E30 standard.
Spooling State Model
SPOOLING
SPOOL
ACTIVE
SPOOL OUTPUT
H*
PURGE
SPOOL
TRANSMIT
SPOOL
3
4
8
POWER
OFF
SPOOL
INACTIVE
7
1
SPOOL
UNLOAD
5/6
NO
SPOOL
OUTPUT
SPOOL
LOAD
SPOOL
FULL
2
SPOOL
NOT
FULL
POWER ON
Figure 49 - GEM Spooling State Model
Spooling State Transitions
Page - 94 - of 324
Jan 28, 2021 Rev 4.2
Kulicke & Soffa™
SECS/GEM Interface for K&S Ball Bonders
Bonder software version x-xx-x-473-series
#
CURRENT
STATE
TRIGGER
EVENT
NEW
STATE
ACTION
COMMENT
1
SPOOL
INACTIVE
Communication
failure detected
SPOOL
ACTIVE
SpoolCountActual and
SpoolCountTotal are
initialized to zero. Any open
transactions with the host
are aborted. SpoolStartTime
(SV) is set to current time.
Alert the operator that
spooling is active
The default state in each OR
substate is entered. The
message which could not be
sent remains in the send queue
and is dealt within Spool Active
state. The collection event
Spooling Activated has occurred
2
SPOOL NOT
FULL
Message generate
which will not fit into
spool area
SPOOL FULL
SpoolFullTime (SV) is set to
current time. Alert the
operator that spool is full
The message which would not fit
into the spooling area is dealt
with after the transition. No
collection event is generated
3
SPOOLOUTPU
T
Spool area emptied
SPOOL
INACTIVE
Spooling process disabled.
Alert the operator that
spooling has been
terminated
The collection event Spooling
Deactivated has occurred.
Transition from the OR substate
Spool Load component occurs
4
NO
SPOOLOUTPU
T
S6,F23 received
w/RSDC=1
PURGE
SPOOL
No action
Initiates purging process. No
collection event is generated
since this is based on host
request
5
NO
SPOOLOUTPU
T
S6,F23 received w/
RSCD=0
TRANSMIT
SPOOL
No action
Initiates message transmission
from spool. No collection event
is generated since this is based
on host request
6
TRANSMITSP
OOL
Comm. failure or
MaxSpool Transmit
reached
NO SPOOL
OUTPUT
Spool transmission process
suspended
If communications failure, the
event Spool Transmit Failure
has occurred. No collection
event generated for
MaxSpoolTransmit reached
7
POWER ON
Equipment power
source discontinued
POWER OFF
No action
Spooling context has been
maintained in non-volatile
storage prior to this transition
8
POWEROFF
Equipment power
source restored
POWER ON
Spooling context restored
from non-volatile memory
If spooling were active prior to
power down, it shall continue. If
TRANSMIT SPOOL were active
at power down, transition #6 is
expected to follow since
communications state is initially
NOT COMMUNICATING
Host Defines Set of Messages to be Spooled
COMMENT
Host defines messages to be
spooled in case of
communications failure.
HOST
S2,F43→
EQUIPMENT
COMMENT
S2,F44
Equipment acknowledges setup.
Figure 50 – Scenario: Host Defines Set of Messages to be Spooled
Define Maximum Number of Messages to Send in Response to S6,F23
COMMENT
Host sends value for equipment
constant MaxSpoolTransmit.
HOST
S2,F15→
EQUIPMENT
S2,F16
COMMENT
Equipment acknowledges
equipment constant change.
Figure 51 – Scenario: Host Defines Maximum Number of Messages to be Sent
Request and Delete Spooled Data
Page - 95 - of 324
Jan 28, 2021 Rev 4.2
Kulicke & Soffa™
SECS/GEM Interface for K&S Ball Bonders
Bonder software version x-xx-x-473-series
COMMENT
Host Requests data that includes
spool related status variables.
If MaxSpoolTransmit not 0,
request spooled data.
Delete spooled data.
HOST
EQUIPMENT
COMMENT
S1,F3→
S1,F4
Send status data.
S6,F24
Request/delete spooled data
acknowledgment.
S6,F23→
S6,F23→
S6,F24
Request/delete spooled data
acknowledgment.
Figure 52 – Scenario: Request and Delete Spooled Data
4.15
Automated Material Movement Management
AGV/OHT Auto Handling System Sequence (Premium Option)
AGV/OHT gets empty magazine
AGV/OHT puts unbonded magazine
AGV/OHT puts empty magazine
AGV/OHT gets bonded magazine
Figure 53 – AGV/OHT Action
Action 1
Loading Tray at Input Magazine Handler
Operation
Sequence
1. Check that there is a (unbonded) magazine on the loading tray. Bonder waits for
magazine to be loaded. A wait message prompt appears.
• If a magazine is loaded, continue with the operation
• If the user selects Abort, the operation terminates
2. The loading belt turns on.
3. The (unbonded) magazine moves to grip position.
4. The bonder signals the host for Load Port Status Changed.
5. The benching kit activates.
6. After a delay time, the benching kit de-activates.
7. The Z tower grips the magazine and moves to slot position.
Page - 96 - of 324
Jan 28, 2021 Rev 4.2
Kulicke & Soffa™
SECS/GEM Interface for K&S Ball Bonders
Bonder software version x-xx-x-473-series
Action 2
Unloading Tray at Input Magazine Handler
Operation
Sequence
1. Check that the unloading tray is empty. If (empty) magazine present, machine
waits for magazine to be removed. A wait message prompt appears.
• If the AGV removes the magazine from the tray, continue with the operation
• If you select Abort, the operation terminates
2. The loading belt turns on.
3. Check the status of the upper tray sensor.
4. The bonder signals the host for Unload Port Status Changed.
Action 3
Loading Tray at Output Magazine Handler
Operation
Sequence
1. Check that there is an empty magazine on the loading tray. Bonder waits
for magazine to be loaded.
• If there is no magazine present on tray, a wait message prompt appears. If
user selects Abort in wait message, the operation terminates
• If magazine (from unloading tray at Input Magazine Handler) is put on the
tray, continue with the operation
2. The loading belt turns on.
3. The (empty) magazine moves to grip position.
4. The bonder signals the host for Load Port Status Changed.
5. The benching kit activates.
6. After a delay time, the benching kit de-activates.
The Z tower grips the magazine and moves to slot position.
Action 4
Operation
Sequence
Unloading Tray at Output Magazine Handler
1. Check that the unloading tray is empty. If (bonded) magazine present,
machine waits for magazine to be removed.
• If there is a (bonded) magazine present on tray, a wait message prompt
appears. If user selects Abort in wait message, the operation
terminates
Page - 97 - of 324
Jan 28, 2021 Rev 4.2
Kulicke & Soffa™
SECS/GEM Interface for K&S Ball Bonders
Bonder software version x-xx-x-473-series
• If the AGV removes the magazine from the tray, continue with the operation
2. The loading belt turns on.
3. Check the status of the lower tray sensor.
4. The bonder signals the host for Unload Port Status Changed.
Page - 98 - of 324
Jan 28, 2021 Rev 4.2
Kulicke & Soffa™
SECS/GEM Interface for K&S Ball Bonders
Bonder software version x-xx-x-473-series
KNS Bonder to Host Events And Applicable SVID
Sensor/Button
IMH load
sensor
tray’s
CEID
SVID
outer 8402 ML_Load_Port_Status_Changed
3817 ML_Load_Port_Status
IMH unload tray’s outer 8403 ML_Unload_Port_Status_Changed
sensor
3818
ML_Unload_Port_Status
OMH load tray’s outer 8404 MR_Load_Port_Status_Changed
sensor
3819 MR_Load_Port_Status
OMH unload tray’s outer 8405 MR_Unload_Port_Status_Changed
sensor
3820
MR_Unload_Port_Status
IMH load tray’s inner limit 8409 ML_Load_Limit_Sns_Status_Changed
sensor
3823
ML_Load_Limit_Sns_Status
OMH load tray’s inner limit 8410 MR_Load_Limit_Sns_Status_Changed
sensor
3824
MR_Load_Limit_Sns_Status
4.16
Enhanced Operator Data Entry
Overview
The existing Operator Entry dialog has been expanded with additional status variable and collection event fields, each
with a corresponding label that can be set using an equipment constant. With this enhanced capability, the host
system can implement up to four additional operator events as needed.
Refresh of the Operator Entry dialogs will not occur while the dialogs are being displayed. If the host system changes
a field label, the change will not become apparent to the operator until the dialog is re-displayed.
Operator Data Entry #1 Dialog - Host Definable Items
Entry
#
1
2
3
4
Label
ECID
1332
1333
1334
1822
EC Value
Assoc. SV Value Default SV
Label Default EC Value
Format
SVID
Format
Value
A[15]
“Enter_Data_A”
3032
A[80]
NULL string
A[15]
“Enter_Data_B”
3033
A[80]
NULL string
A[15]
“Enter_Operator_”
3034
A[80]
NULL string
A[30]
“Send_Operator_Event”
Figure 54 – Host Defineable Operator Entry #1 Dialog Items
Operator Data Entry #2 Dialog - Host Definable Items
Page - 99 - of 324
Jan 28, 2021 Rev 4.2
Kulicke & Soffa™
CEID
8022
SECS/GEM Interface for K&S Ball Bonders
Bonder software version x-xx-x-473-series
Entry
#
1
2
3
4
5
6
7
8
Label
ECID
1391
1392
1393
1394
1891
1892
1893
1894
EC Value
Assoc. SV Value Default SV
Label Default EC Value
Format
SVID
Format
Value
A[15]
“Enter_SV_3091”
3091
A[80]
NULL string
A[15]
“Enter_SV_3092”
3092
A[80]
NULL string
A[15]
“Enter_SV_3094”
3093
A[80]
NULL string
A[15]
“Enter_SV_3095”
3094
A[80]
NULL string
A[30]
“Send_CE_8091”
A[30]
“Send_CE_8092”
A[30]
“Send_CE_8093”
A[30]
“Send_CE_8094”
Figure 55 – Host Defineable Operator Entry #2 Dialog Items
Page - 100 - of 324
Jan 28, 2021 Rev 4.2
Kulicke & Soffa™
CEID
8091
8092
8093
8094
SECS/GEM Interface for K&S Ball Bonders
Bonder software version x-xx-x-473-series
4.17
OS File Download Scenario for Remote Installation
Once the bonder has acknowledged that the command OS_FILE_DWNLD will be performed, it will request the
PACKAGE.INF file from the factory automation host system by initiating the OPEN, READ, and CLOSE
transactions. The file download scenario using the functions of Stream 13 is shown in the table below.
HOST
S2F41 (Host Command Send) ----
BONDER
<---- (Host Command Ack) S2,F42
<---- (Open Data Set Request) S13,F3
S13,F4 (Open Data Set Data) ---<---- (Read Data Set Request) S13,F5
S13,F6 (read Data Set Data) ---<---- (Close Data Set Send) S13,F7
S13,F8 (Close Data Set Ack) ---The GUI message below will be displayed while the file is being downloaded.
File download in progress … Please
standby!
Note:
• The xclient window will be temporarily locked during file transfer to prevent the operator from selecting
any of the operational modes.
• The above message will be removed upon completion of file download or if the reply message timer
expires. If the timer expires then the host would have to send the remote command OS_FILE_DWNLD
again to trigger the file download scenario.
Upon completion of file download the above GUI message will be cleared and the required bonder OS version and
the disk space specified in the PACKAGE.INF file will be verified. The host will be notified, using the existing
Stream 6/ Function 11 (S6F11, Event Report Send) message, whether or not the bonder meets the requirement.
The S6F11 message will be sent with collection event ID 8400 (CEID).
There will be a status variable that will indicate the status of file transfer (See SVID 3048). Once the host is
notified that the bonder meets the requirement for installing/upgrading software, the bonder should request the
PACKAGE.TAR file. The download process will be similar to the scenario used when PACKAGE.INF file was
downloaded. Upon completion of file download, the following GUI message will be displayed while files are
being extracted from the PACKAGE.TAR file.
Preparing files … Please standby!
After the installation files have been extracted, the operator will be prompted with the following message dialog:
Ready to install software version ATX1-8028-2-31..
Press OK to complete OS installation, CANCEL to
abort.
OK
CANCEL
- Pressing the OK button should reboot the bonder from a hard drive partition that has the files needed for OS
installation.
- Pressing the CANCEL button should not initiate OS installation. Instead, an internal flag will be set to indicate that
host has downloaded files needed to install bonder software. This internal flag will be checked next time the Install
item of the Software Options menu is selected. If the flag is set a dialog will be displayed to prompt the operator to
either install the software from the floppy drive or from the hard drive.
Install
Current S/W version : ATX1-8028-2-30
1. From Floppy Drive
2. From Hard Drive (ATX1-8028-2-31)
Done
Page - 101 - of 324
Jan 28, 2021 Rev 4.2
Kulicke & Soffa™
SECS/GEM Interface for K&S Ball Bonders
Bonder software version x-xx-x-473-series
4.18
TRACE: Example OS_FILE_DWNLD scenario
Bonder must be IDLE.
------------------Communications INIT
------------------>>S>>>
>>S>>> S2F41 "Host Command Send"
>>S>>> S2F41R {L:2 {A "OS_FILE_DWNLD"} {L:0 } }
<<<R<<
<<<R<< S2F42 "Host Command Acknowledge"
<<<R<< {2004-11-05 17:07:39} S2F42 {L:2 {B:1 0x04} {L:0}}
<<<R<<
<<<R<< S13F3 "Open Data Set Request"
<<<R<< {2004-11-05 17:07:39} S13F3 {L:3 {U2:1 0} {A:11 PACKAGE_INF} {U4:1 0}}
>>S>>>
>>S>>> S13F4 "Open Data Set Data"
>>S>>> S13F4 {L {U2 0} {A PACKAGE_INF} {B 0} {U2 0} {U4 1}}
<<<R<<
<<<R<< S13F5 "Read Data Set Request"
<<<R<< {2004-11-05 17:07:39} S13F5 {L:2 {U2:1 0} {U4:1 2008683}}
>>S>>>
>>S>>> S13F6 "Read Data Set Data"
>>S>>> S13F6 {L {U2 0} {B 0} {U4 0} {L {B 0x23 0x20 0x50 0x41 0x43 0x4b
--------------- INTENTIONALLY TRUNCATED -----------------0x4f 0x4e 0x45 0x0d 0x0a 0x00}}}
<<<R<<
<<<R<< S13F5 "Read Data Set Request"
<<<R<< {2004-11-05 17:07:40} S13F5 {L:2 {U2:1 0} {U4:1 2008683}}
>>S>>>
>>S>>> S13F6 "Read Data Set Data"
>>S>>> S13F6 {L {U2 0} {B 8} {U4 0} {L}}
<<<R<<
<<<R<< S13F7 "Close Data Set Send"
<<<R<< {2004-11-05 17:07:40} S13F7 {L:1 {U2:1 0}}
>>S>>>
>>S>>> S13F8 "Close Data Set Ack"
>>S>>> S13F8 {L {U2 0} {B 0}}
<<<R<<
<<<R<< S13F3 "Open Data Set Request"
<<<R<< {2004-11-05 17:07:40} S13F3 {L:3 {U2:1 0} {A:11 PACKAGE_TAR} {U4:1 0}}
>>S>>>
>>S>>> S13F4 "Open Data Set Data"
>>S>>> S13F4 {L {U2 0} {A PACKAGE_TAR} {B 0} {U2 0} {U4 1}}
<<<R<<
<<<R<< S13F5 "Read Data Set Request"
<<<R<< {2004-11-05 17:07:40} S13F5 {L:2 {U2:1 0} {U4:1 2016451}}
>>S>>>
>>S>>> S13F6 "Read Data Set Data"
>>S>>> S13F6 {L {U2 0} {B 0} {U4 0} {L {B 0x49 0x4e 0x53 0x54 0x41 0x4c
--------------- INTENTIONALLY TRUNCATED -----------------0xb7 0x86 0xf0 0x4d 0xa8 0x1c }}}
<<<R<<
<<<R<< S13F5 "Read Data Set Request"
<<<R<< {2004-11-05 17:09:33} S13F5 {L:2 {U2:1 0} {U4:1 2016451}}
>>S>>>
>>S>>> S13F6 "Read Data Set Data"
>>S>>> S13F6 {L {U2 0} {B 8} {U4 0} {L}}
<<<R<<
<<<R<< S13F7 "Close Data Set Send"
<<<R<< {2004-11-05 17:09:34} S13F7 {L:1 {U2:1 0}}
>>S>>>
>>S>>> S13F8 "Close Data Set Ack"
>>S>>> S13F8 {L {U2 0} {B 0}}
END TRACE
Page - 102 - of 324
Jan 28, 2021 Rev 4.2
Kulicke & Soffa™
SECS/GEM Interface for K&S Ball Bonders
Bonder software version x-xx-x-473-series
4.19
Data Set Transfers
The Data Set Transfers is used to upload/download non-PP files.
Data Set Upload
The data set upload scenario using the functions of Stream 13 is shown in the table below.
COMMENT
HOST
EQUIPMENT
COMMENT
Open data set.
S13,F3→
S13,F4
Open data set acknowledgment.
Read data set.
S13,F5→
S13,F6
Read data set acknowledgment.
… …
Close data set.
S13,F7→
S13,F8
Close data set acknowledgment.
The files that can be uploaded are as follows.
DATA SET NAMES FOR UPLOAD
Name
Description
BOND_PARM_ACCESS
Password file for limiting the access to change bond parameters.
BOND_PARM_LIMITS
A tar’ed file contraining the bond parameters. Download this file
can change bonder’s parameter opr/process limit.
PBI_LOGLIST
PBI log file list upload.
If there are no PBI log files then Unknown Data Set name will be
returned
If there are PBI log files then a list of PBI log files will be
returned.
PBI_LOG
PBI log file upload.
MDP_FILE
MDP file.
PRIV_OP_ACCESS
Op access password file.
PRIV_SETTINGS
File that contains the present privilege setting, e.g., user, system
manager, etc.
SERVICE_PWD_FILE
This password file should only be downloaded to bonders with
the ZTC option installed.
USER_PWD_FILE
User password file.
BOND_POSITION_ACCESS
Bond position file upload. Upon receiving this message, bonder
will extract bond position to a temp file and transfer this file to the
host. To execute Bond position data transfer, bonder should be
in the IDLE.
Or STANDBY mode, in order to extract bond position info from
the current process program.
INDIVIDUAL_LOG_FILE
Backup an individual bonder log file by setting
EC_Remote_Selected_LogFile.
DEFECT_ID_FILE
Defined cell grade.
CUSTOMIZED_LOG
Customized log.
STRIP_MAP_LOG
Strip map log file upload.
PRIV_USER_DB
Privilege user configuration file upload.
INPUT_GOOD_CELL_GRADE
Input cell grade upload.
INPUT_UNKNOWN_CELL_GRADE
User-defined cell grade upload.
REAL_TIME_3RD_OPT_IMAGES
Real time 3RD opt images file upload.
Data Set Download
The data set download scenario using the functions of Stream 13 is shown in the table below.
Page - 103 - of 324
Jan 28, 2021 Rev 4.2
Kulicke & Soffa™
SECS/GEM Interface for K&S Ball Bonders
Bonder software version x-xx-x-473-series
COMMENT
Send data set.
HOST
EQUIPMENT
COMMENT
S13,F1→
S13,F2
Send data set acknowledgment.
S13,F3
Open data set.
Open data set acknowledgment.
S13,F4→
S13,F5
Read data set.
Read data set acknowledgment.
S13,F6→
… …
S13,F7
Close data set.
Close data set acknowledgment.
S13,F8→
The files that can be downloaded are as follows.
DATA SET NAMES FOR DOWNLOAD
Name
Description
BOND_PARM_ACCESS
Password file for limiting the access to change bond parameters.
BOND_PARM_LIMITS
A tar’ed file contraining the bond parameters. Download this file
can change bonder’s parameter opr/process limit.
MDP_FILE
MDP file.
PRIV_OP_ACCESS
Op access password file.
PRIV_SETTINGS
File that contains the present privilege setting, e.g., user, system
manager, etc.
SERVICE_PWD_FILE
This password file should only be downloaded to bonders with
the ZTC option installed.
USER_PWD_FILE
User password file.
DEFECT_ID_FILE
Defined cell grade.
PRIV_USER_DB
Privilege user configuration file download.
INPUT_GOOD_CELL_GRADE
Input cell grade download.
INPUT_UNKNOWN_CELL_GRADE
User-defined cell grade download.
See section10.5 Appendix for Data Set Transfer.
5.
Message Transfer Protocols
SEMI publishes two message transfer protocols for SECS-II message I/O: High-speed SECS Message Services
(HSMS) and the SEMI Equipment Communications Standard 1 (SECS-I).
NOTE: Interleaving messages is not supported.
5.1
High-speed SECS Message Services (HSMS)
HSMS (SEMI E37) uses a stream sockets interface over a Transmission Control Protocol/Internet Protocol (TCP/IP)
network to send and receive SECS-II messages. HSMS does not specify the physical network medium to be used;
however, 10 Mb Ethernet is generally assumed.
The equipment supports exactly one (1) HSMS port, in single-session (HSMS-SS) mode. The following HSMS
protocol parameters are configurable at the equipment:
Page - 104 - of 324
Jan 28, 2021 Rev 4.2
Kulicke & Soffa™
SECS/GEM Interface for K&S Ball Bonders
Bonder software version x-xx-x-473-series
Name
Device ID
T3 (Reply)
Timeout
T5 (Connect
Separation)
Timeout
T6 (Control
Transaction)
Timeout
T7 (Not
Selected)
Timeout
T8 (Network
Inter-character)
Timeout
Connect Mode
Local IP
Address and
Port Number
Remote IP
Address and
Port Number
HSMS PROTOCOL PARAMETERS
Function
Default
Equipment identifier.
0
Specifies message reply timeout.
45
seconds
Specifies amount of time between
10
successive attempts to connect to a
seconds
remote entity.
Specifies length of time a control
5 seconds
transaction may remain open before it
is considered a communications
failure.
Time a TCP/IP connection can remain
10
in the NOT SELECTED state before it
seconds
is considered a communications
failure.
Maximum allowable time between
5 seconds
successive bytes of an HSMS
message.
Specifies the logic the entity will use
PASSIVE
to establish an HSMS connection.
Required in PASSIVE mode; defines
the local connection entity.
Required in ACTIVE mode; defines
the remote connection entity.
Range
0-32767
1-120
seconds
1-240
seconds
Resolution
1
1 second
1-240
seconds
1 second
1-240
seconds
1 second
1-120
seconds
1 second
ACTIVE/
PASSIVE
-
-
-
-
-
1 second
-
Figure 56 - HSMS Protocol Parameters
The default protocol parameters are in effect only upon initial software installation. The configurable protocol
parameters are stored in non-volatile memory and are restored each time the equipment is reset.
Page - 105 - of 324
Jan 28, 2021 Rev 4.2
Kulicke & Soffa™
SECS/GEM Interface for K&S Ball Bonders
Bonder software version x-xx-x-473-series
5.2
SEMI Equipment Communications Standard 1 (SECS-I)
SECS-I (SEMI E4) uses an RS-232-C serial connection to send and receive SECS-II messages. The equipment
supports exactly one (1) SECS-I port. The following SECS-I protocol parameters are configurable at the equipment:
SECS-I PROTOCOL PARAMETERS
Name
Function
Default
Range
Resolution
Baud Rate
Specifies serial line speed.
9600
300-19200
300, 600, 1200,
2400, 4800,
9600, 19200
Device ID
Equipment identifier.
0
0-32767
1
T1 (InterDetects timeouts between received 0.5 second
0.1-10
0.1 second
Character)
characters.
seconds
Timeout
T2 (Protocol)
Detects lack of protocol response.
10 seconds
0.2-25
0.2 second
Timeout
seconds
T3 (Reply)
Specifies message reply timeout.
45 seconds
1-120
1 second
Timeout
seconds
T4 (Inter-Block)
Specifies inter-block receive
45 seconds
1-120
1 second
Timeout
timeout.
seconds
Retry Limit
Specifies maximum block transmit
3
0-31
1
retries.
Figure 57 - SECS-I Protocol Parameters
The equipment is designated as the Master. The host should be configured as the Slave.
Page - 106 - of 324
Jan 28, 2021 Rev 4.2
Kulicke & Soffa™
SECS/GEM Interface for K&S Ball Bonders
Bonder software version x-xx-x-473-series
6.
APPENDIX 0 - K&S Model Power Series Automatic Ball Bonder and
K&S Model Gen-S Automatic Ball Bonder Shared Items
6.1
Introduction
Appendix 0 contains tables of status variables, equipment constants, collection events, alarms, and data values
which are shared by all models of K&S Model Power Series Automatic Ball Bonder and K&S Model Gen-S
Automatic Ball Bonder.
6.2
K&S Model Power Series Automatic Ball Bonder and K&S Model Gen-S Automatic
Ball Bonder Shared Status Variables
The Status Variables (SVs) and associated Status Variable IDs (SVID) shared by K&S Model Power
Series Automatic Ball Bonder and K&S Model Gen-S Automatic Ball Bonder are described in this section.Unless
otherwise stated, the status variables listed below are not capable of being monitored by Limits Monitoring, as
defined in SEMI E30, section 4.2.4.
Page - 107 - of 324
Jan 28, 2021 Rev 4.2
Kulicke & Soffa™
SECS/GEM Interface for K&S Ball Bonders
Bonder software version x-xx-x-473-series
IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Status Variables
SVID
Name
Type
Description
CommStopped
BL[1]
If the Communications State Model is disabled, then this status
variable determines whether communications are enabled.
(U2)
3000
FALSE = communications enabled
TRUE = communications disabled
3001
CommState
B[1]
Current communications state.
0 = UNKNOWN
1 = COMMUNICATIONS DISABLED
2 = COMMUNICATIONS ENABLED/NOT COMMUNICATING
3 = Host initiated connection waiting for CR from host
4 = Host initiated connection waiting for TX from host
5 = Equipment initiated connection waiting for Host
6 = Wait delay
7 = Communicating
8-63 = Reserved
3002
ControlState
B[1]
Current control state. When reported, it is related to a control
state transition.
0 = UNKNOWN
1 = OFFLINE/EQUIPMENT OFFLINE
2 = OFFLINE/ATTEMPTING TO GO ONLINE
3 = OFFLINE/HOST OFFLINE
4 = ONLINE/LOCAL
5 = ONLINE/REMOTE
6-63 = Reserved
3003
PreviousControlStat
e
B[1]
Previous control state . When reported it is related to a control
state transition.
3004
PPExecName
A[81]
The PPID of the process program which is currently selected.
3007
ProcessState
U1[1]
The current process state of the equipment.
0 = UNKNOWN
1 = PROCESSING NOT ACTIVE - all states other than those
below
2 = AUTO RUN - In Auto mode and bonding
3 = ASSIST - In Auto mode and performing an assist
4 = PAUSED - In Auto mode and paused (Sequence Stop)
5 = WAITING - In Auto mode and not bonding (Backload MMM
only)
6-63 = Reserved
Page - 108 - of 324
Jan 28, 2021 Rev 4.2
Kulicke & Soffa™
SECS/GEM Interface for K&S Ball Bonders
Bonder software version x-xx-x-473-series
IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Status Variables
SVID
Name
Type
Description
3008
PreviousProcessSt
ate
U1[1]
The previous process state of the equipment (see SVID3007
for values).
3009
AlarmsEnabled
L[N]
List of alarm IDs currently enabled for reporting.
3010
AlarmsSet
L[N]
List of alarm IDs currently enabled set.
3011
Clock
A[17]
The current value of the equipment time, format
yyyymmddhhmmsscc.
3012
SpoolCountActual
U4[1]
Count of messages stored in spool.
3013
SpoolCountTotal
U4[1]
Count of total messages directed to the spool, regardless
whether currently in the spool.
3014
SpoolFullTime
A[17]
Timestamp when the spool last became full, format
yyyymmddhhmmsscc
3015
SpoolStartTime
A[17]
Timestamp from when spooling was last activated, format
yyyymmddhhmmsscc
3016
SpoolStateGeneral
B[1]
Current major Spool State.
(U2)
0 = UNKNOWN
1 = SPOOL INACTIVE
2 = SPOOL ACTIVE
3017
SpoolStateLoad
B[1]
The SPOOL LOAD component of SPOOL ACTIVE, set to
UNKNOWN unless SpoolStateGeneral is SPOOL ACTIVE.
0 = UNKNOWN
3 = SPOOL INACTIVE
4 = SPOOL ACTIVE
3018
SpoolStateUnload
B[1]
The SPOOL UNLOAD component of SPOOL ACTIVE, set to
UNKNOWN unless SpoolStateGeneral is SPOOL ACTIVE.
0 = UNKNOWN
5 = SPOOL NO OUTPUT
6 = SPOOL PURGE
7 = SPOOL XMIT
3019
EventsEnabled
L[N]
List of Collection Event Ids that are currently enabled for
reporting.
3021
SV_START_COLU
MN
U2[1]
Start column per index
3022
SV_END_COLUMN
U2[1]
End column per index
Page - 109 - of 324
Jan 28, 2021 Rev 4.2
Kulicke & Soffa™
SECS/GEM Interface for K&S Ball Bonders
Bonder software version x-xx-x-473-series
IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Status Variables
SVID
Name
Type
Description
Equipment Mode
U1[1]
Current equipment mode of operation
(U2)
3030
0 = Idle
1 = Auto
2 = Manual
3 = Program
4 = Configure
5 = Calibration
6 = Utilities
7 = Diagnostic
8 = Sys Admin
9 = Host Initiated Transfer
10 = Equipment Initiated Transfer
11 = Standby (Motor Stop)
12 = Power Save
13 = Restoration
100 = Unintialized
3031
Light Tower State
U2[1]
Current light tower state. This status variable contains a 2 byte
bit encoded data. The bit assignments are:
0 = Not used
1 = Not used
2,3 = Alarm 3 (see note 1)
4,5 = Alarm 2 (see note 1)
6,7 = Alarm 1 (see note 1)
8,9 = White Light (see note 1)
10,11 = Green Light (see note 1)
12,13 = Yellow Light (see note 1)
14,15 = Red Light (see note 1)
Note 1: For all 2 bit codes:
00 = OFF
01 = ON
10 = BLINK OR PULSE
3032
Operator Data A
A[81]
Alpha/Numeric operator data.
3033
Operator Data B
A[81]
Alpha/Numeric operator data.
3034
Operator Data ID
A[81]
Alpha/Numeric operator data.
Page - 110 - of 324
Jan 28, 2021 Rev 4.2
Kulicke & Soffa™
SECS/GEM Interface for K&S Ball Bonders
Bonder software version x-xx-x-473-series
IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Status Variables
SVID
Name
Type
Description
InLoadPortState
U2[1]
Current transfer state of the preprocessing load port.
(U2)
3035
(Backload MMM only)
0 = Port not ready for transfer (Port tray is full)
1 = Port ready for transfer
3036
InUnloadPortState
U2[1]
Current transfer state of the preprocessing unload port.
(Backload MMM only)
0 = Port not ready for transfer (Port tray is empty)
1 = Port ready for transfer (Port tray contains magazine(s)
ready to be picked up by the robot
0 = Port not ready for transfer (Port tray is empty)
1 = Port ready for transfer (Port tray contains magazine(s)
ready to be picked up by the robot)
3037
OutLoadPortState
U2[1]
Current transfer state of the postprocessing load port.
(Backload MMM only)
0 = Port not ready for transfer (Port tray is full)
1 = Port ready for transfer
3038
OutUnloadPortStat
e
U2[1]
Current transfer state of the postprocessing unload port. port.
(Backload MMM only)
0 = Port not ready for transfer (Port tray is empty)
1 = Port ready for transfer (Port tray contains magazine(s)
ready to be picked up by the robot)
3039
SV_Clear_FA_Data
_Dialog
U1[1]
Indicate which operator data dialog cleared all data
Page - 111 - of 324
Jan 28, 2021 Rev 4.2
Kulicke & Soffa™
SECS/GEM Interface for K&S Ball Bonders
Bonder software version x-xx-x-473-series
IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Status Variables
SVID
Name
Type
Description
SV_OpeModeCode
U2[1]
Indicates the current OPEN mode or activity in an OPE mode.
(U2)
3045
1000 - Regular Production
2000 - Engineering
2010 - ENG/Process Engineering
2011 - ENG/Process Engineering/Evaluation Lot
2012 - ENG/Process Engineering/Sample Lot
2013 - ENG/Process Engineering/Setup-Conversion
2020 - ENG/Product Engineering
2021 - ENG/Product Engineering/Evaluation Lot
2022 - ENG/Product Engineering/Sample Lot
2023 - ENG/Product Engineering/Setup-Conversion
2030 - ENG/PEM
2031 - ENG/PEM/M/C Setup
2032 - ENG/PEM/M/C Conversion
2033 - ENG/PEM/M/C Upgrading
3000 - Schedule Activity
3010 - SA/Autonomous Maintenance
3011 - SA/Autonomous Maintenance/Cleaning/Inspection
3012 - SA/Autonomous Maintenance/Small Group
Activity/Training
3020 - SA/Unmanned
3030 - SA/Planned Maintenance
3031 - SA/Planned Maintenance/Routine
Maintenance/Modular PM
3032 - SA/Planned Maintenance/Major PM
3033 - SA/Planned Maintenance/Small Group Activity/Training
3040 - SA/Diagnostic Check
3050 - SA/Calibration
3060 - SA/Plant Shutdown(Reserved)
4000 - SCHDULE DOWNTIME
4010 – No Operator
4020 - No Material
5000 – UN SCHDULE DOWNTIME
6000 - Reserved
7000 – NON- SCHDULED TIME
Page - 112 - of 324
Jan 28, 2021 Rev 4.2
Kulicke & Soffa™
SECS/GEM Interface for K&S Ball Bonders
Bonder software version x-xx-x-473-series
IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Status Variables
SVID
Name
Type
Description
3046
SV_OpeTechID
A[41]
The ID that is entered at the OPE Downtime mode dialog.
3047
SV_PrevToolUsage
U4[1]
The number of times the previous tool was used for bonding
before it was replaced. This status variable is only updated
when the Tool Changed event (CEID 8031) occurs.
3048
FileXfrStat
I2[1]
Status of file transfer in a scenario that uses stream 13
messages.
(U2)
0 = Last data set download was successful
1 = Internal error.
2 = No partition exists.
3 = Unreliable partition.
4 = Invalid or corrupt INF file.
5 = Incompatible version.
6 = Invalid or corrupt TAR file.
95 = Invalid handle.
96 = File creation error.
97 = Unsupported record type.
98 = Host denied open data set request.
99 = Reply timer T3 expired.
3049
SV_BPCLeadSites
L[N]
Pair of lead sites where BPC failed
3050
SV_BPCLeadSiteR
efSys
A[40]
Reference system where BPC failed
3051
USG Impedance
F4[1]
Machine tuned USG Low impedance as displayed in the USG
Calibration dialog.
3052
SV_USGFrequency
F4[1]
Machine free air tuned Low USG frequency.
3053
BITS Status
BL[1]
Auto BITS status as displayed in the BITS Configurations or
Auto Run Configuration dialog.
ON = at least one wire has BITS
enabled.
OFF = no wire has BITS enabled.
3054
SoftwareVersion
A[40]
Current wire bonder software version.
3055
UpgradeSoftwareV
ersion
A[40]
Upgrade version of the downloaded bonder software (i.e. TAR
file) in /tmp0 partition that is to be installed into /sd0 partition.
3056
SV_WireCtrlStartDe
viceName
A[30]
Device name of start control. (max 30 characters)
3057
SV_WireCtrlStopDe
viceName
A[30]
Device name of stop control. (max 30 characters)
Page - 113 - of 324
Jan 28, 2021 Rev 4.2
Kulicke & Soffa™
SECS/GEM Interface for K&S Ball Bonders
Bonder software version x-xx-x-473-series
IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Status Variables
SVID
Name
Type
Description
3058
SV_UsgTouchDow
n
U2[1]
USG bond count.
3059
SV_PbiNumAvlBallI
ds
U1[1]
PBI available ball IDs.
3060
SV_PbiNumAssgnd
BallIds
U1[1]
Number of PBI assigned ball IDs.
3061
SV_PbiGetMeasure
dBallSize
U1[1]
Nominal diameter for the given PBI Ball ID.
3062
SV_HFUSGFreque
ncy
F4[1]
Machine free air tuned High USG frequency.
3063
SV_USGTransduce
rType
I2[1]
3064
SV_HFUSGImpeda
nce
F4[1]
Machine tuned High USG frequency impedance as displayed
in the USG Calibration dialog.
3065
SV_PeriodScanUS
GImpedance
F4[1]
Period Scan USG Impedance (Note: If only enable high
frequency USG on bonder configuration, it should used for HF
USG Impedance. If enable both High/Low frequency, it should
used for LF USG Impedance.
3066
SV_PeriodScanHF
USGImpedance
F4[1]
Period Scan HF USG Impedance
3067
SV_Cover_Gas_Fai
l_Skip_Mode
U2[1]
Cover Gas Fail Skip Mode
3068
SV_Bondsite_Air_B
lower_State
U1[1]
Bondsite Air Blower Configuration.
3070
SV_DeviceCoordin
ate
A[20]
Device coordination (column, row)
3071
SV_OriginLocation
U1[1]
Origin location
3072
SV_AlarmID
U2[1]
Corresponding alarm ID
3073
SV_AlarmDesc
A[81]
Alarm description for alarm ID
3081
SV_UserSV5
A[81]
User SV5 on operator data entry#3 dialog
3082
SV_UserSV6
A[81]
User SV6 on operator data entry#3 dialog
3083
SV_UserSV7
A[81]
User SV7 on operator data entry#3 dialog
3084
SV_UserSV8
A[81]
User SV8 on operator data entry#3 dialog
3085
SV_UserSV9
A[81]
User SV9 on operator data entry#3 dialog
3086
SV_UserSV10
A[81]
User SV10 on operator data entry#3 dialog
3087
SV_UserSV11
A[81]
User SV11 on operator data entry#3 dialog
3088
SV_UserSV12
A[81]
User SV12 on operator data entry#3 dialog
(U2)
USG transducer type (0 – Hign Freq Only, 1 – Dual
Freq)
0=OFF/1=ON/2=Always ON
Page - 114 - of 324
Jan 28, 2021 Rev 4.2
Kulicke & Soffa™
SECS/GEM Interface for K&S Ball Bonders
Bonder software version x-xx-x-473-series
IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Status Variables
SVID
Name
Type
Description
3089
SV_UserSV13
A[81]
User SV13 on operator data entry#3 dialog
3090
SV_UserSV14
A[81]
User SV14 on operator data entry#3 dialog
3091
UserSV1
A[81]
User defined status variable
3092
UserSV2
A[81]
User defined status variable
3093
UserSV3
A[81]
User defined status variable
3094
UserSV4
A[81]
User defined status variable
3096
SV_InhibitAuto
I2[1]
Indicates whether equipment is in “inhibit auto” state.
(U2)
0 = Release inhibit auto state
1 = Inhibit auto state
3100
HitMode
BL[1]
Indicates whether equipment is in Host Initiated Transfer
mode.
FALSE = Equipment is NOT accepting Process Program
transfers from host.
TRUE = Equipment IS accepting Process Program transfers
from host.
3101
UploadPPName
A[81]
Name of Process Program currently being transferred from
equipment to host.
Page - 115 - of 324
Jan 28, 2021 Rev 4.2
Kulicke & Soffa™
SECS/GEM Interface for K&S Ball Bonders
Bonder software version x-xx-x-473-series
3102
UploadPPStatus
B[1]
Status of current process program transfer from equipment to
host.
0 = Last upload was successful.
1 = Ready for upload.
2 = Equipment is requesting permission to upload a process
program to host.
3 = N/A
4 = N/A
5 = N/A
6 = N/A
7 = N/A
8 = N/A
9 = Concatenating process program components into an
uncompressed bundle.
10 = Compressing bundled components into a compressed
bundle.
11 = Process program is ready to be sent to host.
12 = Waiting for host to request prepared process program
bundle.
13 = Transmitting bundled program to host.
14 = N/A
15 = N/A
16 = Preparing Program
17 = Not Used
18 = Error code: memory allocation failure.
19 = Error code: Hard disk write failure.
20 = Error code: Internal failure.
21 = Error code: Illegal upload request.
22 = N/A
23 = Error code: Illegal PPID requested,
24 = N/A
25 = Error code: Operator-initiated upload request denied by
host
26 = N/A
27 = N/A
28 = N/A
29 = Error code: Compression error
30 = Error code: Concatenation error
31 = Error code: Component of program missing
Page - 116 - of 324
Jan 28, 2021 Rev 4.2
Kulicke & Soffa™
SECS/GEM Interface for K&S Ball Bonders
Bonder software version x-xx-x-473-series
IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Status Variables
SVID
Name
Type
Description
(U2)
32 = Error code: Program not found
33 = N/A
34 = Error Code: Reply time T3 timeout.
3103
DownloadPPName
A[81]
Name of Process Program currently being transferred from
host to equipment.
Page - 117 - of 324
Jan 28, 2021 Rev 4.2
Kulicke & Soffa™
SECS/GEM Interface for K&S Ball Bonders
Bonder software version x-xx-x-473-series
3104
Download PPStatus
B[1]
Status of current process program transfer from host to
equipment.
0 = Last download was successful.
1 = Ready for download.
2 = Equipment is requesting permission to download a process
program from host.
3 = Permission has been granted by host for a download.
4 = Receiving process program.
5 = Uncompressing downloaded process program.
6 = Separating downloaded process program components.
7 = Verifying downloaded process program.
8 = Saving downloaded process program to disk.
9 = N/A
10 = N/A
11 = N/A
12 = N/A
13 = N/A
14 = N/A
15 = Loading program to RAM
16 = N/A
17 = N/A
18 = Error code: memory allocation failure.
19 = Error code: Hard disk write failure.
20 = Error code: Internal failure.
21 = Error code: Illegal download request.
22 = Error code: Program exists and cannot be overwritten.
23 = Error code: Illegal PPID requested,
24 = N/A
25 = Error code: Operator-initiated download request denied
by host.
26 = Error code: Decompression error
27 = Error code: Extraction error
28 = Error code: Verification error
29 = N/A
30 = N/A
31 = N/A
32 = N/A
33 = Error Code: Component overwrite not permitted.
Page - 118 - of 324
Jan 28, 2021 Rev 4.2
Kulicke & Soffa™
SECS/GEM Interface for K&S Ball Bonders
Bonder software version x-xx-x-473-series
IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Status Variables
SVID
Name
Type
Description
(U2)
34 = Error Code: Reply time - T3 timed out.
3105
PPEditDialog
A[81]
Name of the GUI dialog where a change was made to the
process program in memory.
3106
PPSelectMode
I4[1]
Process program select mode
0 = by File Name
1 = by Long Name
3107
Bond Parameter
Name
L[N]
Bond parameter names that were modified
3108
Bond Parameter
Value
L[N]
Value of the parameter defined in the status variable Bond
Parameter Name.
3109
Bond Parameter
Wire Group
U2[1]
Wire group where the parameter changes were applied.
3110
Bond Parameter
Change Apply Type
U2[1]
Scope of where parameter changes were applied: Wire,
Group, or All.
3111
Bond Site Number
L[N]
List of bond sites that were modified.
3112
Bond Site X
Coordinate
L[N]
X coordinates for the modified sites listed in the status variable
bondsite Number.
3113
Bond Site Y
Coordinate
L[N]
Y coordinates for the modified sites listed in the status variable
bondsite Number.
3114
Instance Name
A[40]
Filename of the reference system with a bond location change.
3115
Reference System
Filename
A[40]
Filename of the reference system with a bond location change.
Page - 119 - of 324
Jan 28, 2021 Rev 4.2
Kulicke & Soffa™
SECS/GEM Interface for K&S Ball Bonders
Bonder software version x-xx-x-473-series
IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Status Variables
SVID
Name
Type
Description
Completed PP Edit
U2[1]
Last edit performed on the process program in RAM.
(U2)
3116
1 = Changed bond parameter
2 = Changed bond location
3 = Deleted bond site
4 = Resequenced wire
5 = Deleted wire
6 = Added wire
7 = Regrouped wire
8 = N/A
9 = Deleted reference system
10 = Moved reference system
11 = Rotated reference system
12 = Copied reference system
13 = Copied device
14 = Moved device
15 = Deleted device
16 = Resequenced device
17 = Rotated device
18 = Cleared process program in RAM
19 = Retaught pad
20 = Retaught lead
3117
SV_PP_ID
A[80]
PP that was Saved/Renamed/Deleted
3118
SV_PP_SAV_REN
_DEL_STAT
B[1]
Flag for Saved/Renamed/Deleted
3119
SV_BondParmWire
GrpList
L[N]
Bond Parm Wire Group List
3120
SV_LP_Init_PortID
U1[1]
Port id of init port report after machine reboot
1 - input loadport
2 - output unloadport
3 - input unload port
4 - output loadport
Page - 120 - of 324
Jan 28, 2021 Rev 4.2
Kulicke & Soffa™
SECS/GEM Interface for K&S Ball Bonders
Bonder software version x-xx-x-473-series
IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Status Variables
SVID
Name
Type
Description
SV_LP_Init_Transf
er_State
U1[1]
Transfer state of init port report after machine reboot
(U2)
3121
0 - OUT OF SERVICE
1 - TRARNSFER BLOCKED
2 - READY TO LOAD
3 - READY TO UNLOAD
3122
SV_LP_Init_Associ
ation_State
U1[1]
Association state of init port report after machine reboot
0 - NOT ASSOCIATED
1 - ASSOCIATED
3123
SV_LP_Init_Reserv
ation_State
U1[1]
Reservation state of init port report after machine reboot
0 - NOT RESERVED
1 - RESERVED
3124
SV_LP_TransferSta
te_Change_State
U1[1]
Port transfer state of port transfer state changes
0 - OUT OF SERVICE
1 - TRARNSFER BLOCKED
2 - READY TO LOAD
3 - READY TO UNLOAD
3125
SV_LP_TransferSta
te_Change_PortID
U1[1]
Port id of port transfer state changes
1 - input loadport
2 - output unloadport
3 - input unload port
4 - output loadport
3126
SV_LP_TransferSta
te_Change_CarrierI
D
A[80]
Carrier ID of port transfer state changes
3127
SV_AssociationStat
e_Change_State
U1[1]
Port association state of port association state changes
0 - NOT ASSOCIATED
1 - ASSOCIATED
3128
SV_AssociationStat
e_Change_PortID
U1[1]
Port id of port association state changes
1 - input loadport
2 - output unloadport
3 - input unload port
4 - output loadport
Page - 121 - of 324
Jan 28, 2021 Rev 4.2
Kulicke & Soffa™
SECS/GEM Interface for K&S Ball Bonders
Bonder software version x-xx-x-473-series
IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Status Variables
SVID
Name
Type
Description
SV_ReservationSta
te_Change_State
U1[1]
Port reservation state of port reservation state changes
(U2)
3129
0 - NOT RESERVED
1 - RESERVED
3130
SV_ReservationSta
te_Change_PortID
U1[1]
Port id of port reservation state changes
1 - input loadport
2 - output unloadport
3 - input unload port
4 - output loadport
3131
SV_CarrierAccessi
ngStatus_Status
U1[1]
Status of carrier accessing status changes
0 - NOT ACCESSED
1 - IN ACCESS
2 - CARRIER COMPLETE
3 - CARRIER STOPPED
3132
SV_CarrierAccessi
ngStatus_CarrierID
A[80]
Carrier ID that carrier accessing status changes
3133
SV_CarrierAccessi
ngStatus_LocationI
D
A[80]
Location ID that carrier accessing status changes
Note: Bonder does verification at buffer, so location id is
provided. This differs from Micron’s provided workflow. This
item is not required by semi E87
Text for location id, scope as below.
{
P1,
P2,
Buffer1,
Buffer2,
P3,
P4,
}
3134
SV_CarrierIDStatus
_Status
U1[1]
Status of carrier ID status changes
0 - ID NOT READ
1 - ID WAITING FOR HOST
2 - ID VERIFICATION OK
3 - ID VERIFICATION FAILED
3135
SV_CarrierIDStatus
_CarrierID
A[80]
Carrier ID of carrier ID status changes
Page - 122 - of 324
Jan 28, 2021 Rev 4.2
Kulicke & Soffa™
SECS/GEM Interface for K&S Ball Bonders
Bonder software version x-xx-x-473-series
IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Status Variables
SVID
Name
Type
Description
SV_CarrierIDStatus
_LocationID
A[80]
Location ID of carrier ID status changes
(U2)
3136
Note: Bonder does verification at buffer, so location id is
provided. This differs from semi E87 standard
Text for location id, scope as below.
{
P1,
P2,
Buffer1,
Buffer2,
P3,
P4,
}
max 80 characters
3137
SV_SlotMapStatus
_Status
U1[1]
SlotMap Status. Current state of slot map status.
0 - SLOT MAP NOT READ
1 - SLOT MAP WAITING FOR HOST
2 - SLOT MAP VERIFICATION OK
3 - SLOT MAP VERIFICATION FAILED
3138
SV_SlotMapStatus
_CarrierID
A[80]
Carried ID that slotmap status changes
3139
SV_SlotMapStatus
_LocationID
A[80]
Location ID that slotmap status changes
Text for location id, scope as below.
{
P1,
P2,
Buffer1,
Buffer2,
P3,
P4,
}
max 80 characters
3140
SV_AccessMode_
Mode
U1[1]
Current access mode
0 - Manual
1 - Auto
Page - 123 - of 324
Jan 28, 2021 Rev 4.2
Kulicke & Soffa™
SECS/GEM Interface for K&S Ball Bonders
Bonder software version x-xx-x-473-series
IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Status Variables
SVID
Name
Type
Description
SV_AccessMode_P
ortID
U1[1]
Port ID of access mode changes
(U2)
3141
1 - input loadport
2 - output unloadport
3 - input unload port
4 - output loadport
3142
SV_CarrierCreated
_CarrierID
A[80]
CarrierID of carrier created
3143
SV_CarrierCreated
_PortID
U1[1]
Port ID of carrier created
1 - input loadport
2 - output unloadport
3 - input unload port
4 - output loadport
3144
SV_CarrierLoc_Ch
ange_CarrierID
A[80]
Carrier ID that carrier location changes
3145
SV_CarrierLoc_Ch
ange_LocationID
A[80]
Location ID that carrier location changes
Text for location id, scope as below.
{
P1,
P2,
Buffer1,
Buffer2,
P3,
P4,
}
max 80 characters
3146
SV_PortOccupied_
PortID
U1[1]
Port ID indicates which port occupied
1 - input loadport
2 - output unloadport
3 - input unload port
4 - output loadport
Page - 124 - of 324
Jan 28, 2021 Rev 4.2
Kulicke & Soffa™
SECS/GEM Interface for K&S Ball Bonders
Bonder software version x-xx-x-473-series
IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Status Variables
SVID
Name
Type
Description
SV_PortOccupied_
TransferState
U1[1]
Transfer State of port that occupied
(U2)
3147
0 - OUT OF SERVICE
1 - TRARNSFER BLOCKED
2 - READY TO LOAD
3 - READY TO UNLOAD
3148
SV_PortOccupied_
AssociationState
U1[1]
Association state of port that occupied
0 - NOT ASSOCIATED
1 - ASSOCIATED
3149
SV_PortOccupied_
ReservationState
U1[1]
Reservation state of port that occupied
0 - NOT RESERVED
1 - RESERVED
3150
SV_PortEmptyPortI
D
U1[1]
Port ID indicates which load port is empty
1 - input loadport
2 - output unloadport
3 - input unload port
4 - output loadport
3151
SV_CJ_Status_Cha
nge_JobID
A[80]
Control Job ID that status changes
3152
SV_CJ_Status_Cha
nge_Status
U1[1]
Control Job status that status changes.Scope as below
0 - QUEUED
1 - SELECTED
2 - WAITING FOR START
3 - EXECUTING
4 – PAUSED
5 – COMPLETED
3153
SV_PJ_Status_Cha
nge_JobID
A[80]
Process Job ID that status changes
Page - 125 - of 324
Jan 28, 2021 Rev 4.2
Kulicke & Soffa™
SECS/GEM Interface for K&S Ball Bonders
Bonder software version x-xx-x-473-series
IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Status Variables
SVID
Name
Type
Description
SV_PJ_Status_Cha
nge_Status
U1[1]
Process Job status that status changes.Scope as below
(U2)
3154
0 - QUEUED/POOLED
1 - SETTING UP
2 - WAITING FOR START
3 - PROCESSING
4 – PROCESS COMPLETE
5 – (Reserved)
6 - PAUSING
7 - PAUSED
8 - STOPPING
9 - ABORTING
10 - STOPPED
11 - ABORTED
3155
SV_PJ_Status_Cha
nge_RecipeID
A[80]
RecipeID of process job that status changes
3156
SV_CJ_QueueSpa
ce
U1[1]
How many control jobs can be newly created.
Note: Only one control job can be queued. If the queued
control job status is changed to selected, host can queue the
next control job
How many control jobs can be queued
3157
SV_PJ_Queue_Sp
ace
U1[1]
How many process jobs can be newly created.
Note: Only one process job can be queued. If the queued
process job status is changed to setting up, host can queue
the next control job
How many process jobs can be queued.
3158
SV_PortID
U1[1]
Port ID of related state changes
1 - input loadport
2 - output unloadport
3 - input unload port
4 - output loadport
3159
SV_CarrierID
A[80]
Carrier ID of related state changes
3160
SV_LocationID
A[80]
Location ID of related state changes
3161
SV_AccessMode_P
1
U1[1]
Access mode of P1
0 - Manual
1 - Auto
Page - 126 - of 324
Jan 28, 2021 Rev 4.2
Kulicke & Soffa™
SECS/GEM Interface for K&S Ball Bonders
Bonder software version x-xx-x-473-series
IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Status Variables
SVID
Name
Type
Description
SV_AssociationStat
e_P1
U1[1]
Association state of P1
(U2)
3162
0 - NOT ASSOCIATED
1 - ASSOCIATED
3163
SV_ReservationSta
te_P1
U1[1]
Reservation state of P1
0 - NOT RESERVED
1 - RESERVED
3164
SV_TransferState_
P1
U1[1]
Transfer state of P1
0 - OUT OF SERVICE
1 - TRARNSFER BLOCKED
2 - READY TO LOAD
3 - READY TO UNLOAD
3165
SV_AccessMode_P
2
U1[1]
Access mode of P2
0 - Manual
1 - Auto
3166
SV_AssociationStat
e_P2
U1[1]
Association state of P2
0 - NOT ASSOCIATED
1 - ASSOCIATED
3167
SV_ReservationSta
te_P2
U1[1]
Reservation state of P2
0 - NOT RESERVED
1 - RESERVED
3168
SV_TransferState_
P2
U1[1]
Transfer state of P2
0 - OUT OF SERVICE
1 - TRARNSFER BLOCKED
2 - READY TO LOAD
3 - READY TO UNLOAD
3169
SV_AccessMode_P
3
U1[1]
Access mode of P3
0 - Manual
1 - Auto
3170
SV_AssociationStat
e_P3
U1[1]
Association state of P3
0 - NOT ASSOCIATED
1 - ASSOCIATED
3171
SV_ReservationSta
te_P3
U1[1]
Reservation state of P3
0 - NOT RESERVED
1 - RESERVED
Page - 127 - of 324
Jan 28, 2021 Rev 4.2
Kulicke & Soffa™
SECS/GEM Interface for K&S Ball Bonders
Bonder software version x-xx-x-473-series
IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Status Variables
SVID
Name
Type
Description
SV_TransferState_
P3
U1[1]
Transfer state of P3
(U2)
3172
0 - OUT OF SERVICE
1 - TRARNSFER BLOCKED
2 - READY TO LOAD
3 - READY TO UNLOAD
3173
SV_AccessMode_P
4
U1[1]
Access mode of P4
0 - Manual
1 - Auto
3174
SV_AssociationStat
e_P4
U1[1]
Association state of P4
0 - NOT ASSOCIATED
1 - ASSOCIATED
3175
SV_ReservationSta
te_P4
U1[1]
Reservation state of P4
0 - NOT RESERVED
1 - RESERVED
3176
SV_TransferState_
P4
U1[1]
Transfer state of P4
0 - OUT OF SERVICE
1 - TRARNSFER BLOCKED
2 - READY TO LOAD
3 - READY TO UNLOAD
3177
SV_CarrierLocation
Matrix
L[N]
A list all the carriers at/in the equipment. Both internal to the
equipment, and on equipment load ports.
3178
SV_SubstLocID
A[80]
Identifier of substrate location
3179
SV_SubSource
A[83]
Substrate comes from which slot of which input carrier
3180
SV_SubDestination
A[83]
Substrate is ejected to which slot of which output carrier
3181
SV_SlotMapStatus
_SlotMap
L[N]
Slot Map that is waiting for slot map verification
3182
SV_SlotMapStatus
_Reason
U1[1]
The reason of Slot Map waiting for slot map verification
0=verification needed
1=verification by equipment unsuccessful
2=read fail
3=improper substrate position
3183
SV_SubstLocChg_
SubID
A[80]
Substrate ID of substrate location changes
3190
SV_RAMPP_LastS
avedTime
A[15]
Last saved time of the pp in ram
Page - 128 - of 324
Jan 28, 2021 Rev 4.2
Kulicke & Soffa™
SECS/GEM Interface for K&S Ball Bonders
Bonder software version x-xx-x-473-series
IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Status Variables
SVID
Name
Type
Description
3191
SV_DISKPP_LastS
avedTime
A[15]
Last saved time of the pp in disk
3200
Zone1 Temperature
I4[1]
Temperature in degrees Celsius at Pre-Bond. This SV is
capable of being monitored by Limits Monitoring, as defined in
SEMI E30, section 4.2.4
3201
Zone2 Temperature
I4[1]
Temperature in degrees Celsius at Bond. This SV is capable of
being monitored by Limits Monitoring, as defined in SEMI E30,
section 4.2.4
3202
Zone3 Temperature
I4[1]
Temperature in degrees Celsius at Post-Bond. This SV is
capable of being monitored by Limits Monitoring, as defined in
SEMI E30, section 4.2.4
3203
SV_Zone1_Temper
ature_offset
I4[1]
Pre_Bond temperature offset
3204
SV_Zone2_Temper
ature_offset
I4[1]
In_Bond temperature offset
3205
SV_Zone3_Temper
ature_offset
I4[1]
Post_Bond temperature offset
3206
SV_Zone1_Temper
ature_State
U2[1]
Temperature On/Off
3207
SV_Zone2_Temper
ature_State
U2[1]
Temperature On/Off
3208
SV_Zone3_Temper
ature_State
U2[1]
Temperature On/Off
3209
SV_Zone1_Temper
ature_SetPoint
I4[1]
Temperature Setpoint
3210
SV_Zone2_Temper
ature_SetPoint
I4[1]
Temperature Setpoint
3211
SV_Zone3_Temper
ature_SetPoint
I4[1]
Temperature Setpoint
3212
SV_Zone1_Temper
ature_Tolerance
I4[1]
Temperature Tolerance
3213
SV_Zone2_Temper
ature_Tolerance
I4[1]
Temperature Tolerance
3214
SV_Zone3_Temper
ature_Tolerance
I4[1]
Temperature Tolerance
3220
SV_OS_VERSION
A[40]
OS Software version
3221
SV_OS_SERVICE_
PACK
A[40]
OS software service pack
3222
SV_CHGOVER_PA
RTS_PER_CARRI
ER
U1[1]
Parts per carrier for changeover
(U2)
Page - 129 - of 324
Jan 28, 2021 Rev 4.2
Kulicke & Soffa™
SECS/GEM Interface for K&S Ball Bonders
Bonder software version x-xx-x-473-series
IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Status Variables
SVID
Name
Type
Description
3223
SV_CHGOVER_PP
ID
A[81]
Program name for changeover
3224
SV_CHGOVER_TO
OL_FAMILY
A[81]
Tool family for changeover
3225
SV_CHGOVER_WI
REPARTNO
A[81]
Wire part no. for changeover
3226
SV_CHGOVER_IN
_PROGRESS
BL[1]
Whether changeover is in process
3227
SV_PART_ID_IN_P
ROCESS
A[81]
Which part id is in process
3228
SV_CURRENT_IN
STALLED_TOOL_F
AMILY
A[81]
Current installed tool family
3229
SV_CURRENT_IN
STALLED_WIRE_P
ART_NO
A[81]
Current installed wire part no.
3230
SV_TO_BE_INSTA
LLED_TOOL_ID
A[81]
Tool ID to be installed
3231
SV_TO_BE_INSTA
LLED_TOOL_FAMI
LY
A[81]
Tool family to be installed
3232
SV_TO_BE_INSTA
LLED_TOOL_COU
NTER
U4[1]
Tool counter to be installed
3233
SV_TO_BE_INSTA
LLED_WIRE_ID
A[81]
Wire id to be installed
3234
SV_TO_BE_INSTA
LLED_WIRE_PART
_NO
A[81]
Wire part no. to be installed
3235
SV_CURRENT_IN
STALLED_WIRE_I
D
A[81]
Wire ID of current installed wire
3236
SV_PREV_INSTAL
LED_WIRE_ID
A[81]
Wire ID of previous installed wire
3237
SV_CURRENT_IN
STALLED_TOOL_I
D
A[81]
Tool ID of current installed tool
3239
SV_MACHINE_BO
OTUP_TIME
A[21]
Machine Boot Up Time
3240
SV_P1_LotId
A[81]
Text of LotID of mag on input load tray
3241
SV_P2_LotId
A[81]
Text of LotID of mag on output unload tray
(U2)
Page - 130 - of 324
Jan 28, 2021 Rev 4.2
Kulicke & Soffa™
SECS/GEM Interface for K&S Ball Bonders
Bonder software version x-xx-x-473-series
IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Status Variables
SVID
Name
Type
Description
3242
SV_P3_LotId
A[81]
Text of LotID of mag on input unload tray
3243
SV_P4_LotId
A[81]
Text of LotID of mag on output load tray
3244
SV_Buffer1_LotId
A[81]
Text of LotID of mag on input processing unit
3245
SV_Buffer2_LotId
A[81]
Text of LotID of mag on output processing unit
3246
SV_PIO_Continue_
Bit
BL[1]
The status of PIO continue bit
3247
SV_Carrier_Push_
No
U2[1]
Total number of carriers transferred from the loader magazine
3248
SV_Latest_Alarm_
Report
U2[1]
Latest event code which pop up
3249
SV_Latest_Alarm_
Cleared
U2[1]
Latest event code which cleared
3250
SV_Current_Alarm
_Count
U2[1]
Current event count which pop up
3300
Input LF Count
U2[1]
Number of lead frames removed from magazine in input side
gripper.
3301
Output LF Count
U2[1]
Number of lead frames inserted into magazine in output side
gripper.
3302
Devices Processed
U4[1]
Count of devices successfully processed since the equipment
was powered on, or since the host last reset production
counters via RESET_PROD_COUNTERS remote command.
3303
Devices Skipped
U4[1]
Count of devices skipped since the equipment was powered
on, or since the host last reset production counters via
RESET_PROD_COUNTERS remote command.
3304
Input Bar Code
A[81]
Bar Code of magazine in input side gripper. Valid if Input Scan
Status SV = 0 or 1.
3305
Output Bar Code
A[81]
Bar Code of magazine in output side gripper. Valid if Output
Scan Status SV = 0 or 1.
3306
Material Source Bar
Code
A[81]
Bar Code number of the source magazine. Like the Input Bar
Code SV, but qualified as having been accepted by the EQC.
3307
Input Scan Status
B[1]
Status of bar code scan of magazine in input side gripper.
(U2)
0 = OK
1 = bar code keyed in manually
2 = scan failed
3308
Output Scan Status
B[1]
Status of bar code scan of magazine in output side gripper.
0 = OK
1 = bar code keyed in manually
2 = scan failed
Page - 131 - of 324
Jan 28, 2021 Rev 4.2
Kulicke & Soffa™
SECS/GEM Interface for K&S Ball Bonders
Bonder software version x-xx-x-473-series
IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Status Variables
SVID
Name
Type
Description
SV_MagEjectOpt
BL[1]
Magazine Eject Option
(U2)
3309
Ported to Central by FEA1264
3310
SV_WHL_Status
BL[1]
The status indicates whether whl has L/F or not
3319
SV_2D_CODE
A[81]
2D Code scanned by 2D reader.
3320
SV_STRIP_ID
A[81]
ID of Strip Map, which uniquely identifies the strip map.
3321
SV_STRIP_ROW
U4[1]
The number of rows of Strip Map.(Download from host)
3322
SV_STRIP_COLU
MN
U4[1]
The number of columns of Strip Map.(Download from host)
3323
SV_STRIP_ORIGI
NLOCATION
U1[1]
Coordinate system of Strip Map to address devices.
0 = N/A
1 = Upper right (UR) - top side,
2 = Upper left (UL) - top side,
3 = Lower left (LL) - top side,
4 = Lower right (LR) - top side,
6 = Upper right (UR) - bottom side,
7 = Upper left (UL) - bottom side,
8 = Lower left (LL) - bottom side,
9 = Lower right (LR) - bottom side.
10 = N/A
3324
SV_STRIP_CELLS
TATUS
L[N]
A list of values indicating the value of each unit on a strip.
0 = Good,
1 = Unknown,
2 = Defect
3325
SV_STRIP_LOTID
A[30]
Production lot identifier this data.
3326
SV_STRIP_TRANS
ACTION
I2[1]
Strip transaction
3327
SV_STRIP_CELLG
RADE
L[N]
A list of values indicating the classification of each unit on a
strip. Custom in Strip Map configuration dialog.
3328
SV_UPLOAD_MAP
_STRIP_ID
A[81]
Strip ID for uploaded strip map data
3329
SV_STRIP_CELL_
COORDINATE
A[20]
Strip cell coordinate (Format: Col-Row)
3330
SV_EXPECTED_S
TRIP_ROW
U4[1]
Expected strip row number based on process program
3331
SV_EXPECTED_S
TRIP_COL
U4[1]
Expected strip column number based on process program
Page - 132 - of 324
Jan 28, 2021 Rev 4.2
Kulicke & Soffa™
SECS/GEM Interface for K&S Ball Bonders
Bonder software version x-xx-x-473-series
IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Status Variables
SVID
Name
Type
Description
3332
SV_STRIP_WIRE_
USAGE
F4[1]
Wire usage of current processed strip. Unit is Feet. It is
guaranteed to be updated when strip map ready for upload
event (CEID 8336) occurs.
3350
SV_SAFETY_KIT_
STATUS
BL[1]
Safety sensor status
3360
SV_BFC_Scale_Fa
ctor
F4[1]
Bond Force Scale Factor
3361
SV_EFO_Cal_Heig
ht
F4[1]
EFO Calibration Height Value
3362
SV_RealTime_3rd_
Opt_Option
U4[1]
Real Time 3rd Option
3363
SV_DummyState
U1[1]
Dummy mode State: 0 = Normal; 1=Dummy;2=Local
(U2)
1 = Dummy
Dummy mode state
0 = Normal
1 = Dummy2 = Local
3364
SV_Realtime_FAB_
Flow_Rate
F4[1]
Real time FAB gas flow rate
3365
SV_Realtime_Bond
_Flow_Rate
F4[1]
Real time bond gas flow rate
3366
SV_Realtime_Clam
p_Flow_Rate
F4[1]
Real time clamp gas flow rate
3367
SV_LHM_MEASUR
ED_WIRE_LOOP_I
D
L[N]
Loop ID of each measured wire
3368
SV_LHM_DEVICE_
RESULT
U1[1]
Measurement result of reported device
(0 – Within Limit
1 – Exceeds Error Limit
2 – Exceeds Warning Limit)
3369
SV_LHM_MEASUR
ED_WIRE_ID
L[N]
Measured wire IDs
3370
SV_LHM_MAX_LO
OP_HEIGHT_SAM
PLE_QTY
U4[1]
Number of maximum loop height samples
3371
SV_LHM_MAX_LO
OP_HEIGHT_VAL
UES
L[N]
Maximum loop height of each measured wire
3372
SV_LHM_EDGE_H
EIGHT_SAMPLE_
QTY
U4[1]
Number of edge height samples
Page - 133 - of 324
Jan 28, 2021 Rev 4.2
Kulicke & Soffa™
SECS/GEM Interface for K&S Ball Bonders
Bonder software version x-xx-x-473-series
IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Status Variables
SVID
Name
Type
Description
3373
SV_LHM_EDGE_H
EIGHT_VALUES
L[N]
Edge height of each measured wire
3374
SV_LHM_MAX_LO
OP_HEIGHT_LEA
RNED_VALUES
L[N]
Learned maximum loop height of each measured wire
3375
SV_LHM_EDGE_C
LEARANCE_LEAR
NED_VALUES
L[N]
Learned edge height of each measured wire
3376
SV_LHM_LOOP_H
EIGHT_WARN_UP
PER_LIMITS
L[N]
Upper warning limits (loop height) for each measured wire
3377
SV_LHM_LOOP_H
EIGHT_WARN_LO
WER_LIMITS
L[N]
Lower warning limits (loop height) for each measured wire
3378
SV_LHM_LOOP_H
EIGHT_ERROR_U
PPER_LIMITS
L[N]
Upper error limits (loop height) for each measured wire
3379
SV_LHM_LOOP_H
EIGHT_ERROR_L
OWER_LIMITS
L[N]
Lower error limits (loop height) for each measured wire
3380
SV_LHM_EDGE_C
LEARANCE_WAR
N_UPPER_LIMITS
L[N]
Upper warning limits (edge height) for each measured wire
3381
SV_LHM_EDGE_C
LEARANCE_WAR
N_LOWER_LIMITS
L[N]
Lower warning limits (edge height) for each measured wire
3382
SV_LHM_EDGE_C
LEARANCE_ERRO
R_UPPER_LIMITS
L[N]
Upper error limits (edge height) for each measured wire
3383
SV_LHM_EDGE_C
LEARANCE_ERRO
R_LOWER_LIMITS
L[N]
Lower error limits (edge height) for each measured wire
3384
SV_LHM_MAX_LO
OP_HEIGHT_MEA
S_CODE
A[20]
Code for maximum loop height measurement
3385
SV_LHM_EDGE_H
EIGHT_MEAS_CO
DE
A[20]
Code for edge height measurement
3386
SV_LHM_LOOP_H
EIGHT_ASSIGNED
_LOOP_ID
L[N]
Loop IDs that are assigned to loop height measurement
(U2)
Page - 134 - of 324
Jan 28, 2021 Rev 4.2
Kulicke & Soffa™
SECS/GEM Interface for K&S Ball Bonders
Bonder software version x-xx-x-473-series
IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Status Variables
SVID
Name
Type
Description
3387
SV_LHM_LOOP_H
EIGHT_ASSIGNED
_LOOP_ID_WARN
_UPPER_LIMITS
L[N]
Upper warning limits (loop height) correspond to
SV_LHM_LOOP_HEIGHT_ASSIGNED_LOOP_ID
3388
SV_LHM_LOOP_H
EIGHT_ASSIGNED
_LOOP_ID_WARN
_LOWER_LIMITS
L[N]
Lower warning limits (loop height) correspond to
SV_LHM_LOOP_HEIGHT_ASSIGNED_LOOP_ID
3389
SV_LHM_LOOP_H
EIGHT_ASSIGNED
_LOOP_ID_ERRO
R_UPPER_LIMITS
L[N]
Upper error limits (loop height) correspond to
SV_LHM_LOOP_HEIGHT_ASSIGNED_LOOP_ID
3390
SV_LHM_LOOP_H
EIGHT_ASSIGNED
_LOOP_ID_ERRO
R_LOWER_LIMITS
L[N]
Lower error limits (loop height) correspond to
SV_LHM_LOOP_HEIGHT_ASSIGNED_LOOP_ID
3391
SV_LHM_EDGE_H
EIGHT_ASSIGNED
_LOOP_ID
L[N]
Loop IDs that are assigned to edge height measurement
3392
SV_LHM_EDGE_H
EIGHT_ASSIGNED
_LOOP_ID_WARN
_UPPER_LIMITS
L[N]
Upper warning limits (edge height) correspond to
SV_LHM_EDGE_HEIGHT_ASSIGNED_LOOP_ID
3393
SV_LHM_EDGE_H
EIGHT_ASSIGNED
_LOOP_ID_WARN
_LOWER_LIMITS
L[N]
Lower warning limits (edge height) correspond to
SV_LHM_EDGE_HEIGHT_ASSIGNED_LOOP_ID
3394
SV_LHM_EDGE_H
EIGHT_ASSIGNED
_LOOP_ID_ERRO
R_UPPER_LIMITS
L[N]
Upper error limits (edge height) correspond to
SV_LHM_EDGE_HEIGHT_ASSIGNED_LOOP_ID
3395
SV_LHM_EDGE_H
EIGHT_ASSIGNED
_LOOP_ID_ERRO
R_LOWER_LIMITS
L[N]
Lower error limits (edge height) correspond to
SV_LHM_EDGE_HEIGHT_ASSIGNED_LOOP_ID
3396
SV_LHM_HOST_V
ALIDATION_STAT
E
U1[1]
Auto Loop Height Measurement Host Validation State
3401
SV_Osc_Current_F
actor
F4[1]
USG current factor in Osc / Amp Results menu
3402
SV_Person_Curren
t_Factor
F4[1]
USG current factor in Personality Values
3403
SV_MDP_ModifyNa
me
L[N]
This SV is for generic MDP Parameter change report
(U2)
Page - 135 - of 324
Jan 28, 2021 Rev 4.2
Kulicke & Soffa™
SECS/GEM Interface for K&S Ball Bonders
Bonder software version x-xx-x-473-series
IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Status Variables
SVID
Name
Type
Description
3404
SV_MDP_ModifyVa
lue
L[N]
This SV is for generic MDP Parameter change report
3405
SV_HF_Osc_Curre
nt_Factor
F4[1]
High Frequency USG current factor in Osc / Amp Results
menu
3406
SV_HF_Person_Cu
rrent_Factor
F4[1]
High Frequency USG current factor in Personality Values
3417
SV_RCMD_InMag
I2[1]
Input magazine is accepted or rejected remotely by host. (0 =
Accepted, 1 = Rejected)
3418
SV_RMCD_OutMa
g
I2[1]
Output magazine is accepted or rejected remotely by host. (0 =
Accepted, 1 = Rejected)
3420
SV_LatestErrorSub
Coordinate
A[10]
Substrate Col/Row information of latest error
3421
SV_LatestErrorInst
ance
A[40]
Instance Name of latest error
3476
SV_ToolUsageHour
sInUse
U4[1]
(updated under process error and PRS error only)
Tool has been used in hours
3477
SV_ToolChanged
A[18]
Time that tool changed
3478
SV_CAP_CLEAN_
COUNT
U2[1]
Count for cap clean has been done
3479
SV_TapeUsedTouc
hDown
U4[1]
Count for tap touch down on tap
3480
SV_TapeRemainTo
uchDown
U4[1]
Touch down that not used
3481
SV_WireUsed
F4[1]
Wire length that has been used
3482
SV_TimeRemaining
F4[1]
Time remain
3500
Wires Bonded
U4[1]
PM SV: Number of wires bonded during Engineering Time and
Productive Time.
3501
Devices Bonded
U4[1]
PM SV: Number of devices bonded.
3502
Standby Time
F4[1]
PM SV: Time bonder was up, but was in Standby Mode (see
SEMI E-10). [Hrs.]
3503
Productive Time
F4[1]
PM SV: Time bonder was up and executing Auto Mode (see
SEMI E-10). [Hrs.]
3504
Engineering Time
F4[1]
PM SV: Sum of Standby Time and Productive Time. [Hrs.]
3505
Bonder Utilization
F4[1]
PM SV: Percent of Productive Time during total time
(PM_StopTime - PM_StartTime).
3506
Net MTBAp
F4[1]
PM SV: Mean (productive) Time Between Assists. [Hrs.]
3507
MCBA
F4[1]
PM SV: Mean Cycles (devices processed) Between Assists.
3508
Gross UPH
F4[1]
PM SV: Units Per Hour in any mode since PM_StartTime.
(U2)
(updated under process error and PRS error only)
Page - 136 - of 324
Jan 28, 2021 Rev 4.2
Kulicke & Soffa™
SECS/GEM Interface for K&S Ball Bonders
Bonder software version x-xx-x-473-series
IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Status Variables
SVID
Name
Type
Description
3509
Net UPH
F4[1]
PM SV: Units Per Hour in auto mode since PM_StartTime.
3510
EFO
U4[1]
PM SV: Number of EFO Open exceptions.
3511
Devices Skipped
U4[1]
PM SV: Number of devices skipped, owing to process
exceptions.
3512
MHS Interrupts
U4[1]
PM SV: Number of MHS related errors, including following
categories and errors.
(U2)
•
WHL:
MHSEyeFailure;
InjectorPuller;
BondingSite;
IndexerTucker;
JamDetect;
Sensor;
•
Mag Handler:
InputMagOperation;
InputMagSensor;
OutputMagOperation;
OutputMagSensor;
•
Material:
NoInputMaterial; /* Input Mag. Empty */
OutputMagFull;
3513
NSOP
U4[1]
PM SV: Number of No Stick On Pad or broken wire
exceptions.
3514
NSOL
U4[1]
PM SV: Number of No Stick On Lead or bad tail exceptions.
3515
Short Tails
U4[1]
PM SV: Number of short tail exceptions.
3516
Assists
U4[1]
PM SV: Number of events requiring assists.
3517
MTBFp
F4[1]
PM SV: Mean Time Between Failures
3518
MCBF
F4[1]
PM SV: Mean Cycles Between Failures
3519
Net Failures
U4[1]
PM SV: Total failures due to machine out-of-spec.
3520
Tool Usage
U4[1]
Non-PM SV: The number of times the tool has been used for
bonding.
3521
Wire Remaining
F4[1]
Non-PM SV: The wire length remaining in the spool.
3522
Lot Device Bonded
U4[1]
Non-PM SV: Number of devices bonded in the current lot.
3523
Temperature Errors
U4[1]
PM SV: Number of temperature errors
3524
Missing Wire Detect
U4[1]
PM SV: Missing wire error count (For wedge)
Page - 137 - of 324
Jan 28, 2021 Rev 4.2
Kulicke & Soffa™
SECS/GEM Interface for K&S Ball Bonders
Bonder software version x-xx-x-473-series
IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Status Variables
SVID
Name
Type
Description
3525
Device Eye Failures
U4[1]
PM SV: Device eye failure count.
3526
VLL Find Failures
U4[1]
PM SV: Number of VLL find failures.
3527
Line Tolerance
Failures
U4[1]
PM SV: Number of Line Tolerance failures.
3528
No Input Materials
U4[1]
PM SV: Empty input magazine tray error count.
3529
Output Mag Full
U4[1]
PM SV: Full output magazine tray error count.
3530
Wire Feed Error
U4[1]
PM SV: Number of Wire feed failures.
3531
Air Supply Low
U4[1]
PM SV: Low air pressure error count
3532
MHS Eye Failures
U4[1]
PM SV: Number of MHS Eye failures.
3533
Injector Puller
U4[1]
PM SV: Number of Injector puller failures.
3534
Bonding Site
U4[1]
PM SV: Number of Bonding site failures.
3535
Indexer Tucker
U4[1]
PM SV: Number of Indexer Tucker failures.
3536
Jam Detect
U4[1]
PM SV: Number of workholder jams.
3537
Workholder Sensor
U4[1]
PM SV: Number of Workholder sensor failures.
3538
Input Mag
Operation
U4[1]
PM SV: Number of Input magazine operation failures.
3539
Input Mag Sensor
U4[1]
PM SV: Number of Input magazine sensor failures.
3540
Output Mag
Operation
U4[1]
PM SV: Number of Output magazine operation failures.
3541
Output Mag Sensor
U4[1]
PM SV: Number of Output magazine sensor failures.
3542
SV_PbiUnitTime
A[21]
PBI unit time(YY/MM/DD HH:MM:SS)
3543
SV_PbiUnitNumber
U4[1]
PBI unit number
3544
SV_PbiUnitAvgBall
Dia
F4[1]
Average ball diameter
3545
SV_PbiUnitBallDia
Min
F4[1]
Minimum Ball Diameter.
3546
SV_PbiUnitBallDia
Max
F4[1]
Maximum Ball Diameter
3547
SV_PbiUnitBallDia
ErrCnt
U4[1]
Ball diameter error count
3548
SV_PbiUnitBallFind
FailCnt
U4[1]
Ball find failure count
3549
SV_PbiUnitAvgXBa
llPlcErr
F4[1]
Average X Ball Placement error
3550
SV_PbiUnitXBallPlc
ErrMin
F4[1]
Minimum X Ball Placement error
(U2)
Page - 138 - of 324
Jan 28, 2021 Rev 4.2
Kulicke & Soffa™
SECS/GEM Interface for K&S Ball Bonders
Bonder software version x-xx-x-473-series
IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Status Variables
SVID
Name
Type
Description
3551
SV_PbiUnitXBallPlc
ErrMax
F4[1]
Maximum X Ball Placement error
3552
SV_PbiUnitXBallPlc
ErrCnt
U4[1]
X Ball Placement error count
3553
SV_PbiUnitAvgYBa
llPlcErr
F4[1]
Average Y Ball Placement error
3554
SV_PbiUnitYBallPlc
ErrMin
F4[1]
Minimum Y Ball Placement e
3555
SV_PbiUnitYBallPlc
ErrMax
F4[1]
Maximum Y Ball Placement error
3556
SV_PbiUnitYBallPlc
ErrCnt
U4[1]
Y Ball Placement error count
3557
SV_PbiUnitAvgXW
edgePlcErr
F4[1]
Average X Stitch Placement error
3558
SV_PbiUnitXWedg
ePlcErrMin
F4[1]
Minimum X Stitch Placement error
3559
SV_PbiUnitXWedg
ePlcErrMax
F4[1]
Maximum X Stitch Placement error
3560
SV_PbiUnitXWedg
ePlcErrCnt
U4[1]
X Stitch Placement error count
3561
SV_PbiUnitAvgYW
edgePlcErr
F4[1]
Average Y Stitch Placement error
3562
SV_PbiUnitYWedg
ePlcErrMin
F4[1]
Minimum Y Stitch Placement error
3563
SV_PbiUnitYWedg
ePlcErrMax
F4[1]
Maximum Y Stitch Placement error
3564
SV_PbiUnitYWedg
ePlcErrCnt
U4[1]
Y Stitch Placement error count
3565
SV_PbiUnitWedgeF
indFailCnt
U4[1]
Stitch Find Failure count
3566
SV_PbiSumStartTi
me
A[21]
PBI summary start time(YY/MM/DD HH:MM:SS).
3567
SV_PbiSumPkgCnt
U4[1]
Number of Packages Inspected
3568
SV_PbiSumDevCnt
U4[1]
Number of Devices Inspected
3569
SV_PbiSumWireCn
t
U4[1]
Number of Wires Inspected
3570
SV_PbiSumAvgBall
Dia
F4[1]
Average Ball Diameter
3571
SV_PbiSumStdDev
BallDia
F4[1]
Standard Deviation of Ball Diameters
(U2)
Page - 139 - of 324
Jan 28, 2021 Rev 4.2
Kulicke & Soffa™
SECS/GEM Interface for K&S Ball Bonders
Bonder software version x-xx-x-473-series
IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Status Variables
SVID
Name
Type
Description
3572
SV_PbiSumBallDia
Min
F4[1]
Minimum Ball Diameter
3573
SV_PbiSumBallDia
Max
F4[1]
Maximum Ball Diameter
3574
SV_PbiSumBallDia
ErrCnt
U4[1]
Ball Diameter error count
3575
SV_PbiSumBallFin
dFailCnt
U4[1]
Ball Find Failure count
3576
SV_PbiSumAvgXB
allPlcErr
F4[1]
Average X Ball Placement error
3577
SV_PbiSumStdDev
XBallPlcErr
F4[1]
Standard Deviation of X Ball Placement errors
3578
SV_PbiSumXBallPl
cErrMin
F4[1]
Minimum X Ball Placement error
3579
SV_PbiSumXBallPl
cErrMax
F4[1]
Maximum X Ball Placement error
3580
SV_PbiSumXBallPl
cErrCnt
U4[1]
X Ball Placement error count
3581
SV_PbiSumAvgYB
allPlcErr
F4[1]
Average Y Ball Placement error
3582
SV_PbiSumStdDev
YBallPlcErr
F4[1]
Standard Deviation of Y Ball Placement errors
3583
SV_PbiSumYBallPl
cErrMin
F4[1]
Minimum Y Ball Placement error
3584
SV_PbiSumYBallPl
cErrMax
F4[1]
Maximum Y Ball Placement error
3585
SV_PbiSumYBallPl
cErrCnt
U4[1]
Y Ball Placement error count
3586
SV_PbiSumAvgXW
edgePlcErr
F4[1]
Average X Stitch Placement error
3587
SV_PbiSumStdDev
XWedgePlcErr
F4[1]
Standard Deviation of X Stitch Placement errors
3588
SV_PbiSumXWedg
ePlcErrMin
F4[1]
Minimum X Stitch Placement error
3589
SV_PbiSumXWedg
ePlcErrMax
F4[1]
Maximum X Stitch Placement error
3590
SV_PbiSumXWedg
ePlcErrCnt
U4[1]
X Stitch Placement error count
3591
SV_PbiSumAvgYW
edgePlcErr
F4[1]
Average Y Stitch Placement error
(U2)
Page - 140 - of 324
Jan 28, 2021 Rev 4.2
Kulicke & Soffa™
SECS/GEM Interface for K&S Ball Bonders
Bonder software version x-xx-x-473-series
IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Status Variables
SVID
Name
Type
Description
3592
SV_PbiSumStdDev
YWedgePlcErr
F4[1]
Standard Deviation of Y Stitch Placement errors
3593
SV_PbiSumYWedg
ePlcErrMin
F4[1]
Minimum Y Stitch Placement error
3594
SV_PbiSumYWedg
ePlcErrMax
F4[1]
Maximum Y Stitch Placement error
3595
SV_PbiSumYWedg
ePlcErrCnt
U4[1]
Y Stitch Placement error count
3596
SV_PbiSumWedge
FindFailCnt
U4[1]
Stitch Find Failure count
3597
Small Ball Detect
U4[1]
PM SV: Small ball detected
3598
Bond Height Error
U4[1]
PM SV: Bond height error detected
3599
PBI Error
U4[1]
PM SV: PBI error detected
3600
FALSE NSOP
U2[1]
PM SV: False NSOP detected
3601
AUTOREBOND
ATTEMPTS
U2[1]
PM SV: Auto re-bond attempts
3602
AUTO REBOND
NON ATTEMPTS
U2[1]
PM SV: Auto re-bond non attempts
3603
AUTO REBOND
SUCCESSES
U2[1]
PM SV: Auto re-bond successes
3604
AssistTime
F4[1]
PM SV: Accumulated assist time = The time when the operator
is performing assist to recovery form errors.
3605
VLL FM Detection
U4[1]
PM SV: Accumulated VLL foreign material detection.
3606
Material Assist
U4[1]
PM SV: Accumulated material assist.
3607
Schedule DwnTime
F4[1]
PM SV: Accumulated schedule downtime when operator is
changing consumbles: capillary and wire.
3608
UnSchedule
DwnTime
F4[1]
PM SV: Accumulated un-schedule downtime when machine is
stopped and receiving assists by operator.
3609
NonScheduleT ime
F4[1]
PM SV: Accumulated non-schedule time when required to
bring machine to be usable after software/hardware upgrade.
3610
TotalTime
F4[1]
PM SV: Accumulated total time.
3611
Wait for Opr
F4[1]
PM SV: Accumulated time waiting for operator.
3612
Gross MTBA
F4[1]
PM SV: Gross MTBA.
3613
Gross Assists
U4[1]
PM SV: Gross accumulated assists.
3614
SV_LatestErrorCon
text
U4[1]
Non-PM SV: Latest error context.
3615
SV_LatestErrorDevi
ce
U4[1]
Non-PM SV: Latest error device.
(U2)
Page - 141 - of 324
Jan 28, 2021 Rev 4.2
Kulicke & Soffa™
SECS/GEM Interface for K&S Ball Bonders
Bonder software version x-xx-x-473-series
IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Status Variables
SVID
Name
Type
Description
3616
SV_LatestErrorWire
U4[1]
Non-PM SV: Latest error wire.
3617
SV_LatestErrorBon
d
U4[1]
Non-PM SV: Latest error bond.
3618
Die Eye Failure
U4[1]
PM SV: Accumulated die eye points failures.
3619
Lead Eye Failure
U4[1]
PM SV: Accumulated lead eye points failures.
3620
Substrate Eye
Failure
U4[1]
PM SV: Accumulated substrate eye points failures.
3621
Long Tails
U4[1]
PM SV: Accumulated long tail exceptions in SSB process.
PM SV: Accumulated long tail exceptions in SSB process
3622
FALSE NSOL
U2[1]
PM SV: Accumulated false NSOL reported by BITS.
3623
NetDevicesBonded
U4[1]
PM SV: Accumulated PM Net Device Bonded.
3624
SV_PbiUnitBallDia
PlcFailRate
F4[1]
PBI Unit Ball Diameter Placement Fail Rate
3625
SV_PbiSumBallDia
PlcFailRate
F4[1]
PBI Sum Ball Diameter Placement Fail Rate
3626
SV_PM_Bump_NS
OP
U4[1]
PM statistic for ssb bump nsop error.
3627
SV_PM_Bump_SH
TL
U4[1]
PM statistic for ssb bump short tail error.
3628
SV_PM_Bump_SB
D
U4[1]
PM statistic for ssb bump small ball detected error.
3629
SV_PM_Bump_Lift
U4[1]
PM statistic for ssb bump lift error.
3630
SV_PM_LBD
U4[1]
Large ball error statistics
3631
SV_PM_Bump_LB
D
U4[1]
Bump large ball error staistics
3632
SV_PM_AUTO_SH
TL_RECV_ATTEM
PTS
U4[1]
Attempts that auto recovery tries after SHTL
3633
SV_PM_AUTO_SH
TL_RECV_SUCCE
SSES
U4[1]
Success that auto recovery done after SHTL
3634
SV_PM_AUTO_EF
O_OPEN_RECV_A
TTEMPTS
U4[1]
Attempts that auto recovery tries after EFO OPEN
3635
SV_PM_AUTO_EF
O_OPEN_RECV_S
UCCESSES
U4[1]
Success that auto recovery done after EFO OPEN
3636
SV_PM_NSOL_RE
WORK_ATTEMPT
S
U4[1]
PM statistic for NSOL Auto Rework attempts.
(U2)
Page - 142 - of 324
Jan 28, 2021 Rev 4.2
Kulicke & Soffa™
SECS/GEM Interface for K&S Ball Bonders
Bonder software version x-xx-x-473-series
IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Status Variables
SVID
Name
Type
Description
3637
SV_PM_NSOL_RE
WORK_SUCCESS
U4[1]
PM statistic for NSOL Auto Rework success.
3638
SV_PM_AUTO_SH
TL_FALSE_ALARM
U4[1]
False shtl alarm count
3639
SV_PM_IndexVacu
um
U4[1]
PM SV: Number of Index Vacuum Error
3641
SV_PM_DRPAllErr
ors
U4[1]
Accumulated all the DRP errors
3650
SV_PM_Center_De
v_1stWire_2ndBnd
_BH
F4[1]
First Wire Second Bond Bond Height
3651
SV_PM_WireInspe
ctionError
U4[1]
PM SV: Number of wire inspection errors
3660
SV_RailHeightVal
F4[1]
Rail height value
3661
SV_RailHeightState
I4[1]
Rail height state
3662
SV_PbiUnitBallFind
IgnoreCnt
U4[1]
Ball find ignore count
3663
SV_PbiSumBallFin
dIgnoreCnt
U4[1]
Ball Find Ignore count
3670
SV_Die_Eye_Fail_
Skip_Filter
U1[1]
Die Eye Fail skip device filter: By Count/By Time/By Count&By
Time
3671
SV_Lead_Eye_Fail
_Skip_Filter
U1[1]
Lead Eye Fail skip device filter: By Count/By Time/ By
Count&By Time
3672
SV_Die_LTOL_Fail
_Skip_Filter
U1[1]
Die Line Tolerance Fail skip device filter: By Count/By Time/
By Count&By Time
3673
SV_Lead_LTOL_Fa
il_Skip_Filter
U1[1]
Lead Line Tolerance Fail skip device filter: By Count/By Time/
By Count&By Time
3674
SV_NSOP_Skip_Fil
ter
U1[1]
NSOP skip device filter: By Count/By Time/ By Count&By Time
3675
SV_NSOL_Skip_Fil
ter
U1[1]
NSOL skip device filter: By Count/By Time/ By Count&By Time
3676
SV_SHTL_Skip_Filt
er
U1[1]
SHTL skip device filter: By Count/By Time/ By Count&By Time
3677
SV_Wire_Feed_Err
_Skip_Filter
U1[1]
Wire Feed Error skip device filter: By Count/By Time/ By
Count&By Time
3678
SV_PBI_Wire_Stop
_Skip_Filter
U1[1]
PBI Eire Stop Error skip device filter: By Count/By Time/ By
Count&By Time
3679
SV_Cover_Gas_Fai
l_Skip_Filter
U1[1]
Cover Gas Fail skip device filter: By Count/By Time/ By
Count&By Time
(U2)
Page - 143 - of 324
Jan 28, 2021 Rev 4.2
Kulicke & Soffa™
SECS/GEM Interface for K&S Ball Bonders
Bonder software version x-xx-x-473-series
IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Status Variables
SVID
Name
Type
Description
3680
SV_DRP_Errors_S
kip_Filter
U1[1]
DRP Error skip device filter: By Count/By Time/ By Count&By
Time
3700
SV_PM_SSB_Stitc
h_NSOL
U4[1]
PM SV: SSB Stitch NSOL
3701
SV_PM_SSB_Stitc
h_SHTL
U4[1]
PM SV: SSB Stitch SHTL
3702
SV_PM_DevicesAu
toSkippedTotal
U4[1]
PM SV: Total Devices Auto Skipped
3703
SV_PM_DevicesAu
toSkippedPRS
U4[1]
PM SV: PRS Devices Auto Skipped
3704
SV_PM_DevicesAu
toSkippedNSOP
U4[1]
PM SV: NSOP Devices Auto Skipped
3705
SV_PM_DevicesAu
toSkippedNSOL
U4[1]
PM SV: NSOL Devices Auto Skipped
3706
SV_PM_DevicesAu
toSkippedSHTL
U4[1]
PM SV: SHTL Devices Auto Skipped
3707
SV_PM_DevicesAu
toSkippedRejEP
U4[1]
PM SV: Reject Eye Point Devices Auto Skipped
3708
SV_PM_DevicesAu
toSkippedProbeNo
Die
U4[1]
PM SV: Probe No Die Devices Auto Skipped
3709
SV_PM_DevicesAu
toSkippedPBI
U4[1]
PM SV: PBI Devices Auto Skipped
3710
SV_PM_DevicesAu
toSkippedDRP
U4[1]
PM SV: DRP Devices Auto Skipped
3711
SV_PM_DevicesAu
toSkippedCoverGa
s
U4[1]
PM SV: Cover Gas Devices Auto Skipped
3712
SV_PM_DevicesAu
toSkippedWireFeed
U4[1]
PM SV: Wire Feed Devices Auto Skipped
3713
SV_PM_DevicesAu
toSkippedIBB
U4[1]
PM SV: IBB Devices Auto Skipped
3714
SV_PM_DevicesAu
toSkippedUnionDev
ice
U4[1]
PM SV: Union Device Devices Auto Skipped
3715
SV_PM_DevicesAu
toSkippedVacuumP
ortEmpty
U4[1]
PM SV: Vacuum Port Empty Devices Auto Skipped
3790
SV_First_Bond_Se
g_Mode
U1[1]
First bond seg mode: 0-Classic, 1-ProBond
(U2)
Page - 144 - of 324
Jan 28, 2021 Rev 4.2
Kulicke & Soffa™
SECS/GEM Interface for K&S Ball Bonders
Bonder software version x-xx-x-473-series
IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Status Variables
SVID
Name
Type
Description
3791
SV_Second_Bond_
Seg_Mode
U1[1]
Second bond seg mode: 0-Classic, 1-ProStitch
3800
SV_BONDING_PA
RM_GROUP_LIST
L[N]
List of bonding parameter group. Need enable EC1239 to
update value.
3801
SV_1ST_BOND_TI
ME
L[N]
List of the first bond time. Need enable EC1239 to update
value.
3802
SV_1ST_USG_BO
ND_CURRENT
L[N]
List of the first USG bond current. Need enable EC1239 to
update value
3803
SV_1ST_BOND_F
ORCE
L[N]
List of the first bond force. Need enable EC1239 to update
value.
3804
SV_1ST_TIP
L[N]
List of the first Tip. Need enable EC1239 to update value.
3805
SV_1ST_CV
L[N]
List of the first CV. Need enable EC1239 to update value.
3806
SV_2ND_BOND_TI
ME
L[N]
List of the second bond time. Need enable EC1239 to update
value.
3807
SV_2ND_USG_BO
ND_CURRENT
L[N]
List of the second USG bond current. Need enable EC1239 to
update value.
3808
SV_2ND_BOND_F
ORCE
L[N]
List of the second bond force. Need enable EC1239 to update
value.
3809
SV_2ND_TIP
L[N]
List of the second Tip. Need enable EC1239 to update value.
3810
SV_2ND_CV
L[N]
List of the second CV. Need enable EC1239 to update value.
3811
SV_FAB_SIZE
L[N]
List of fab size. Need enable EC1239 to update value.
3812
SV_EFO_CURREN
T
L[N]
List of EFO current. Need enable EC1239 to update value.
3813
SV_KINK_HEIGHT
L[N]
List of kink height. Need enable EC1239 to update value.
3814
SV_REVERSE_MO
TION
L[N]
List of reverse motion. Need enable EC1239 to update value.
3815
SV_LOOP_FACTO
R
L[N]
List of loop factor. Need enable EC1239 to update value.
3816
SV_PM_RefDriftFai
lure
U4[1]
Number of Reference Drift failures.
3817
ML_Load_Port_Stat
us
BL[1]
Left maghandler loading tray outer sensor status.
3818
ML_Unload_Port_S
tatus
BL[1]
Left maghandler unloading tray outer sensor status.
3819
MR_Load_Port_Sta
tus
BL[1]
Right maghandler loading tray outer sensor status.
3820
MR_Unload_Port_S
tatus
BL[1]
Right maghandler loading tray outer sensor status.
(U2)
Page - 145 - of 324
Jan 28, 2021 Rev 4.2
Kulicke & Soffa™
SECS/GEM Interface for K&S Ball Bonders
Bonder software version x-xx-x-473-series
IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Status Variables
SVID
Name
Type
Description
3821
AGV_Control_Statu
s
BL[1]
AGV control ON/OFF.
3822
AGV_VALID_Statu
s
BL[1]
AGV valid status. (1 = AGV is present, 0 = AGV is not present)
3823
ML_Load_Limit_Sn
s_Status
BL[1]
Left maghandler loading tray limit sensor status.
3824
MR_Load_Limit_Sn
s_Status
BL[1]
Right maghandler loading tray limit sensor status.
3825
OHT_Control_Statu
s
BL[1]
Status change of OHT magazine load control.
3829
SV_IncompleteCal
A[600]
Incomplete calibration items.
3830
SV_LATEST_SUC
CESSFUL_CAL
A[81]
The latest successful calibration item
3831
SV_Package_Bondi
ng_Status
U1[1]
Bonder Status
3840
SV_Lot_State
B[1]
Current Lot Status
3841
SV_Lot_ID
A[31]
Current Lot ID
3842
SV_Lot_Remaning
_Mag_Num
I4[1]
Current Lot Remaining Mag Number
3843
SV_Lot_Total_Mag
_Num
I4[1]
Current Lot Total Mag Number
3844
SV_Lot_OPID
A[31]
Current Lot Operator ID
3850
SV_WIRE_USAGE
_PER_UNIT
F4[1]
Average Wire Usage per Unit
3851
SV_AVAILABLE_B
OND_UNIT_CURR
_SPOOL
U4[1]
Avaiable Bond Unit that can be bonded with current wire spool
3852
SV_WIRE_USAGE
_DEV_BOND
F4[1]
Wire Usage Device Bond
3853
SV_WIRE_USAGE
_NON_DEV_BOND
F4[1]
Wire Usage Non Device Bond
3854
SV_Remove_Wire_
Spool_ID
A[20]
Removed Wire Spool ID
3855
SV_Install_Wire_Sp
ool_ID
A[20]
Installed Wire Spool ID
3856
SV_WireSpoolMoni
_OPID
A[20]
Lot OPID
3857
SV_SpoolDevicesB
onded
U4[1]
The bonded device number of current wire spool
3858
SV_PrevWireUsage
F4[1]
The number of used wire before wire spool is replaced
(U2)
Page - 146 - of 324
Jan 28, 2021 Rev 4.2
Kulicke & Soffa™
SECS/GEM Interface for K&S Ball Bonders
Bonder software version x-xx-x-473-series
IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Status Variables
SVID
Name
Type
Description
3859
SV_DRP_Errors_S
kip_Mode
U2[1]
DRP errors auto skip mode
3860
SV_Auto_Err_Skip_
Sub_Coordinate
A[10]
Auto skip device coordinate with format(Col-Row)
3861
SV_Auto_Err_Skip_
Event_CL
U2[1]
Auto skip error’s event classification
3862
SV_NSOP_Skip_M
ode
U2[1]
NSOP skip mode
3863
SV_NSOL_Skip_M
ode
U2[1]
NSOL skip mode
3864
SV_SHTL_Skip_Mo
de
U2[1]
SHTL skip mode
3865
SV_Die_Eye_Fail_
Skip_Mode
U2[1]
Die Eye Fail skip mode
3866
SV_Lead_Eye_Fail
_Skip_Mode
U2[1]
Lead Eye Fail skip mode
3867
SV_Die_LTOL_Fail
_Skip_Mode
U2[1]
Die Line TOL Fail skip mode
3868
SV_Lead_LTOL_Fa
il_Skip_Mode
U2[1]
Lead Line TOL Fail skip mode
3869
SV_Wire_Feed_Err
_Skip_Mode
U2[1]
Wire Fees Error skip mode
3870
SV_PBI_Wire_Stop
_Skip_Mode
U2[1]
PBI Wire Stop Error skip mode
3871
SV_ID_INFO
A[81]
Grasped ID info
3872
SV_Wire_Clamp_T
otal_Usage
U4[1]
Wire Clamp Total Usage
3873
SV_Wire_Clamp_Li
fetime
F4[1]
Wire Clamp Lifetime
3874
SV_CM_LOG_NAM
E
A[81]
Name of customized log file
3875
SV_CM_LOG_STA
RTTIME
A[15]
Start time of customized log file (yyyymmddhhmmss)
3876
SV_CM_LOG_END
TIME
A[15]
End time of customized log file (yyyymmddhhmmss)
3880
SV_NumAvlWireIns
pIds
U1[1]
Wire Inspection: Number of available wire inspection IDs
3881
SV_NumTaughtWir
eInspIds
U1[1]
Wire Inspection: Number of taught wire inspection IDs
(U2)
Page - 147 - of 324
Jan 28, 2021 Rev 4.2
Kulicke & Soffa™
SECS/GEM Interface for K&S Ball Bonders
Bonder software version x-xx-x-473-series
IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Status Variables
SVID
Name
Type
Description
3882
SV_NumAssgndWir
eInspIds
U1[1]
Wire Inspection: Number of assigned wire inspection IDs
3883
SV_WireInspUnitTi
me
A[21]
Wire Inspection: Unit time(YY/MM/DD HH:MM:SS)
3884
SV_WireInspUnitFi
ndFailCnt
U4[1]
Wire Inspection: Find failure count for last unit
3885
SV_WireInspUnitAv
gWireSway
F4[1]
Wire Inspection: Average wire sway for last unit
3886
SV_WireInspSumSt
artTime
A[21]
Wire Inspection: Summary
3887
SV_WireInspSumP
kgCnt
U4[1]
Wire Inspection: Number of Packages wire inspected
3888
SV_WireInspSumD
evCnt
U4[1]
Wire Inspection: Number of Devices wire inspected
3889
SV_WireInspSumW
ireInspCnt
U4[1]
Wire Inspection: Summary inspection count
3890
SV_WireInspSumFi
ndFailCnt
U4[1]
Wire Inspection: Summary find failure count
3891
SV_WireInspSumEr
rCnt
U4[1]
Wire Inspection: Summary wire sway error count
3892
SV_WireInspIDInsp
Cnt
U4[1]
Wire Inspection: Inspect count for specific ID
3893
SV_WireInspIDFind
FailCnt
U4[1]
Wire Inspection: Find failure count for specific ID
3894
SV_WireInspIDErrC
nt
U4[1]
Wire Inspection: Error count for specific ID
3895
SV_WireInspIDAvg
WireSway
F4[1]
Wire Inspection: Average wire sway for specific ID
3896
SV_WireInspIDStd
DevWireSway
F4[1]
Wire Inspection: Standard deviation for specific ID
3897
SV_WireInspIDWire
SwayMin
F4[1]
Wire Inspection: Min wire sway for specific ID
3898
SV_WireInspIDWire
SwayMax
F4[1]
Wire Inspection: Max wire sway for specific ID
4016
SV_1ST_FORCE_
PROFILING
L[N]
List of the first force profiling. Need enable EC1239 to update
value.
4017
SV_1ST_X_SCRU
B
L[N]
List of the first X scrub. Need enable EC1239 to update value.
4018
SV_1ST_Y_SCRU
B
L[N]
List of the first Y scrub. Need enable EC1239 to update value.
(U2)
Start time(YY/MM/DD HH:MM:SS)
Page - 148 - of 324
Jan 28, 2021 Rev 4.2
Kulicke & Soffa™
SECS/GEM Interface for K&S Ball Bonders
Bonder software version x-xx-x-473-series
IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Status Variables
SVID
Name
Type
Description
4019
SV_1ST_SCRUB_
CYCLES
L[N]
List of the first scrub cycles. Need enable EC1239 to update
value.
4020
SV_2ND_TAIL_SC
RUB_MODE
L[N]
List of the second tail scrub mode. Need enable EC1239 to
update value.
4021
SV_2ND_TAIL_XY
_SCRUB
L[N]
List of the second tail XY scrub. Need enable EC1239 to
update value.
4022
SV_2ND_TAIL_SC
RUB_CYCLES
L[N]
List of the second tail scrub cycles. Need enable EC1239 to
update value.
4023
SV_BUMP_BOND_
POWER
L[N]
List of bump Bond power. Need enable EC1239 to update
value.
4024
SV_BUMP_BOND_
FORCE
L[N]
List of bump bond force. Need enable EC1239 to update
value.
4025
SV_BUMP_FORCE
_PROFILING
L[N]
List of bump force profiling. Need enable EC1239 to update
value.
4026
SV_BUMP_SCRUB
_CYCLES
L[N]
List of bump scrub cycles. Need enable EC1239 to update
value.
4027
SV_BUMP_BOND_
OFFSET
L[N]
List of bump bond offset. Need enable EC1239 to update
value.
4028
SV_LOOP_FAB_SI
ZE
L[N]
List of loop fab size. Need enable EC1239 to update value.
4029
SV_BITS_ENABLE
D
L[N]
List of BITS enable status. Need enable EC1239 to update
value.
4030
SV_Shuffled_LogFil
e_OriginalNam
A[81]
The shuffled log file original name. Will be updated while
CE_LogFile_Shuffled occurred.
4031
SV_Shuffled_LogFil
e_TargetNam
A[81]
The shuffled log file target name. Will be updated while
CE_LogFile_Shuffled occurred
(U2)
Figure 58 – K&S Model Power Series Automatic Ball Bonder and K&S Model Gen-S Automatic Ball Bonder
Shared Status Variables
6.3
K&S Model Power Series Automatic Ball Bonder and K&S Model Gen-S Automatic
Ball Bonder Shared Equipment Constants
The Equipment Constant values (ECVs) and associated Equipment Constant IDs (ECIDs) shared by K&S Model
Power Series Automatic Ball Bonder and K&S Model Gen-S Automatic Ball Bonder are described in this section.
Page - 149 - of 324
Jan 28, 2021 Rev 4.2
Kulicke & Soffa™
SECS/GEM Interface for K&S Ball Bonders
Bonder software version x-xx-x-473-series
ECID
(U2)
1000
IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Equipment Constants
Name
Type
Description
Default
Communications
State
B[1]
1001
Default
State
B[1]
1002
Communication
State Model
BL[1]
1003
BL[1]
1006
1007
1008
Disable
Process
Program
Load
Inquire
Establish
Communications
Timeout
MDLN
SOFTREV
Starting SVID
1009
DeviceID
U2[1]
1010
MaxSpool
Transmit
U4[1]
1011
OverWriteSpool
BL[1]
1012
Comm
State
Callback Response
Control
State
Callback Response
Load
Inquire
Callback Response
Download Callback
Response
Upload
Callback
Response
Directory Callback
Response
Validate
Comm
Start
Callback
Response
Remote Command
Callback Response
I4[1]
1005
1013
1014
1015
1016
1017
1018
1019
Control
U2[1]
A[7]
A[32]
U2[1]
I4[1]
I4[1]
I4[1]
I4[1]
I4[1]
I4[1]
I4[1]
The initial communicatisons state. Host read-only.
1 = COMM DISABLED
2 = COMM ENABLED/NOTCOMMUNICATING
3-255 = Reserved
The initial control state. Host read-only.
1 = OFFLINE/EQUIPMENT OFFLINE
2 = OFFLINE/ATTEMPTING TO GO ONLINE
3 = OFFLINE/HOST OFFLINE
4 = ONLINE/LOCAL
5 = ONLINE/REMOTE
6-63 = Reserved
Flag used to enable or disable the GEM Communication State
Model. If the flag is set to FALSE, then the S1,F1 Are You There
Request (R) /S1,F2 On Line Data (D) transaction is used instead
of the S1,F13 Establish Communications Request (CR)/ S1,F14
Establish Communications Request Acknowledge (CRA)
transaction to establish communications. The default value is
set to TRUE.
Flag used to disable the requirement of process program load
inquire before equipment is sent a multi-block process program.
The default value of this flag is zero (false).
The length of time, in seconds, of the interval between attempts
to send S1,F13 Establish Communications Request (CR)
messages when establishing communications.
Equipment model type. Host read-only.
Software revision. Host read-only.
The start variable ID number for status variables. Host readonly.
The device ID which is used for SECS II messages. Host readonly.
Maximum number of messages to transmit when an S6,F23
Request Spooled Data (RSD) message is received from the
host. If 0, no limit.
Either overwrite the spool when spooling area becomes full, or
stop adding messages to the spool.
Default response if no application code callback is registered for
communication state changes.
Default response if no application code callback is registered for
control state changes.
Default response if no application code callback is registered for
host initiated process program download inquiries.
Default response if no application code callback is registered for
host initiated process program download requests.
Default response if no application code callback is registered for
host initiated process program upload requests.
Default response if no application code callback is registered for
host initiated process program directory requests.
Default response if no application code callback is registered for
host attempting to establish communications.
Default response if no application code callback is registered for
remote commands from host.
Page - 150 - of 324
Jan 28, 2021 Rev 4.2
Kulicke & Soffa™
SECS/GEM Interface for K&S Ball Bonders
Bonder software version x-xx-x-473-series
ECID
(U2)
1020
IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Equipment Constants
Name
Type
Description
Default
S1F2
Response
Default
Offline
Control State
Starting CEID
I4[1]
Default response to host sending S1F1.
B[1]
1023
Default
Enabled
BL[1]
1024
Number of SVIDs
U2[1]
1025
B[1]
1026
1027
1028
1029
1032
Default
Online
Control State
Starting ALID
Starting RPTID
Starting DataID
Last SVID
S6 F11 Reply
New control state when host fails to respond to or denies an
operator initiated attempt to go on-line.
The start variable ID number for collection events. Host readonly.
Flag used to enabled disable HSMS communications upon
equipment startup. Valid only when Using HSMS equipment
constant is TRUE.
Maximum number of status variables that can be configured on
equipment. This EC and Starting SVID define the valid range of
SVIDs.
New control state when equipment goes online.
1033
1034
Starting DVID
Number of DVIDs
U2[1]
U2[1]
1035
SpoolMode
BL[1]
1036
1037
EC_DefOpeMode
EC_OpeTechIdOpt
U2[1]
I2[1]
The start variable ID number for alarms. Host read-only.
The start variable ID number for reports. Host read-only.
The start variable ID number for data IDs. Host read-only.
The ending variable ID number for data IDs. Host read-only.
Flag used to determine if equipment should expect a reply to
S6F11 messages.
The starting ID number for data values. Host read-only.
Maximum number of data values that can be configured on
equipment. This EC and Starting DVID define the valid range
of DVIDs. Host read-only.
Message spooling control (except Stream 1, i.e., S1F1, S1F13).
FALSE = disable spooling
TRUE = enable spooling
Default Ope mode
Ope down time configuration
1038
EC_OpeModeChgT
mr
EC_OpeAlrmClrTm
r
EC_PrevOpeMode
RcmdStartTmr
Tool
Usage
Warning Level
I4[1]
Ope change timer
I4[1]
Ope alarm clear timer
U2[1]
I2[1]
F4[1]
Tool Usage Bond
Limit
Tool Usage Hour
Limit
EC_BondProximity
Check
EC_WireSpoolLeng
th
EC_PbiState
EC_PbiBallSizeInsp
State
EC_PbiBallLocInsp
State
U4[1]
Previously saved OPE mode
Process start (remote command) timer. Default as 10 seconds.
Tool usage level in percent (< 100%) that must be reached
before the collection event Approaching Tool Usage Limit is sent
to the host.
Tool usage bond limit count.
U4[1]
Tool Usage Hour Limit
BL[1]
Tool usage time limit in hours.
F4[1]
BL[1]
BL[1]
Total wire length. It is the wire spool length that is normally
specified in the Wire Usage dialog.
PBI enable. (TRUE = On; FALSE = Off)
PBI: Ball size inspection. (TRUE = On; FALSE = Off)
BL[1]
PBI: Ball placement inspection. (TRUE = On; FALSE = Off)
1021
1022
1039
1040
1041
1042
1043
1044
1045
1046
1047
1048
1049
HSMS
U2[1]
U2[1]
U2[1]
U2[1]
U2[1]
BL[1]
Page - 151 - of 324
Jan 28, 2021 Rev 4.2
Kulicke & Soffa™
SECS/GEM Interface for K&S Ball Bonders
Bonder software version x-xx-x-473-series
ECID
(U2)
1050
1051
1052
1053
IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Equipment Constants
Name
Type
Description
EC_PbiWedgeInsp
Enable
EC_PbiInspUnit
EC_PbiActualBallDi
a
EC_PbiBallFindDia
Tol
BL[1]
PBI: Wedge placement inspection. (TRUE = On; FALSE = Off)
B[1]
F4[1]
PBI: Inspection unit. (0 = Package; 1 = Device)
PBI: Actual ball diameter.
F4[1]
PBI: Ball find diameter tolerance.
The Max Value for this ECID is the current value of ECID 1052
(EC_PbiActualBallDia)
1054
1055
1056
1057
1058
1059
1060
1061
1062
1063
1064
1065
1066
1067
1068
1069
1070
1071
1072
1073
1074
EC_PbiAutoThresh
old
EC_PbiBinThreshol
d
EC_PbiNumSample
s
EC_PbiSamplingM
ethod
EC_PbiRandomSa
mpling
EC_PbiSamplePerc
ent
EC_PbiReqMeasur
ePerWire
EC_PbiTriesPerWir
eMax
EC_PbiRealignStat
e
EC_PbiBallDiaTol
BL[1]
Can only be modified if there is a process program in RAM.
If not, returns 6 in EAC return
PBI: Auto Threshold (TRUE = On; FALSE = Off)
F4[1]
PBI: Binary threshold value (0 - 255)
U2[1]
PBI: Sample every n units.
B[1]
BL[1]
PBI: Sampling method (0 = last n wires; 1 = user selected wires;
2 = all wires)
PBI: Random sampling (TRUE = On; FALSE = Off)
F4[1]
PBI: Sample percentage (1 - 100)
U2[1]
PBI: Required measurement per wire (value >= 1)
I2[1]
PBI: Maximum tries per wire (value >= 1)
BL[1]
PBI: Realign before inspection (TRUE = On; FALSE = Off)
F4[1]
EC_PbiBallXLocTol
EC_PbiBallYLocTol
EC_PbiFailStopMo
de
EC_ApplyParmLimi
ts
F4[1]
F4[1]
B[1]
INHIBIT_AUTO_RU
N_WITHOUT_PBI
EC_PbiSkipDevice
EC_PbiProcNomDi
a
EC_PbiBallSizeBia
sBasis
EC_PbiBallSizeBia
sValid
EC_PbiBallSizeBia
sValue
EC_PbiExtBallFind
ParmSetID
BL[1]
PBI: Ball diameter inspection tolerance (value = percentage of
nominal ball diameter)
PBI: Ball X placement inspection tolerance.
PBI: Ball Y placement inspection tolerance.
PBI: Failure machine stop mode (0 = don’t stop on failure; 1 =
stop on unit average failure; 2 = stop on any inspection failure)
Flag used to enable or disable application of parameter limits to
the current program in RAM after downloading bond parameter
limits files to the bonder.
Inhibit auto run without PBI ball signature reteach
U2[1]
F4[1]
Support PBI Skip Device
PBI: Process Nominal Ball Diameter.
B[1]
PBI: Ball Size Biasing Basis.
BL[1]
PBI: Ball Size Bias Valid Flag.
F4[1]
PBI: Ball Size Bias Value.
B[1]
PBI: Ext Ball Find Parm Set ID.
BL[1]
Page - 152 - of 324
Jan 28, 2021 Rev 4.2
Kulicke & Soffa™
SECS/GEM Interface for K&S Ball Bonders
Bonder software version x-xx-x-473-series
ECID
(U2)
1075
1076
1077
1078
1079
1080
1081
1082
1083
1084
1085
1086
IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Equipment Constants
Name
Type
Description
EC_PBILogFileDay
s
U2[1]
EC_TimeBeforePo
werSave
EC_PowerSaveCon
fig
EC_TimeBeforeBon
ding
EC_Heaters
EC_AirGuide
EC_NUMERIC_LIM
IT_OPTION
EC_ToolUsageBon
dCountType
EC_SaveComCtrlSt
ate
U4[1]
PBI: Maximum age for archived PBI log files. PBI log files that
have resided on the number longer than the number of days
specified by EC_PBILogLifeDays will be deleted from the
bonder and their entries from PBILIST.LOG
Change in TimeBeforePowerSave
BL[1]
PowerSaveConfiguration ON/OFF
U4[1]
Change in TimeBeforeBonding
BL[1]
BL[1]
U1[1]
Heaters Yes/No
Air Guide Yes/No
The bonder shall allow the host to read & modify the
configuration for Numeric Limit Action.
Counter Type: 0=Down, 1=Up
EC_Worklight
EC_Monitor
EC_EnterHitExtAcc
ess
BL[1]
BL[1]
BL[1]
U4[1]
BL[1]
TRUE = Attempt to resume to the last known GEM
Communication and Control State after a power failure or other
power cycle
FALSE = Off
Work light Yes/No
Monitor Yes/No
Flag used to allow execution of ENTER_HIT remote command
at any operational mode except at Auto Run mode.
FALSE = Default setting. ENTER_HIT remote command is
restricted at Idle and Sequence Stop mode.
TRUE = Allows ENTER_HIT remote command at any
operational mode except Auto Run mode. (Note: The existing
requirement to inhibit Auto in Sequence Stop mode remains the
same.)
1087
1088
1089
1090
1091
1092
1093
Note: In the Modify Equipment Constant dialog this equipment
constant will have the label 'Enter HIT Command Extended
Access'
PBI: Breakpoint Enable State
EC_PbiBrkPntsEna
bled
EC_OutputMagEjec
tWarning
EC_EjectThreshold
Warning
EC_EjectThreshold
BL[1]
EC_WireCtrlStartSt
ate
EC_WireCtrlStartSit
e
EC_WireCtrlStartWi
re
U1[1]
If set to TRUE, the Output Mag Eject Warning will be displayed
when an output magazine is ejected
If set to TRUE, the Eject Threshold Warning will displayed when
the Eject Threshold of a magazine is reached
The number of strips which are left to be ejected before the the
output magazine is full. It is the triggering point for Eject
Threshold Warning.NOTE: Max number up to 5
Start Control Mode. (0 = OFF; 1 = ONCE; 2 = ALWAYS)
U2[1]
Start Device.
U2[1]
Start Wire.
BL[1]
BL[1]
U1[1]
Page - 153 - of 324
Jan 28, 2021 Rev 4.2
Kulicke & Soffa™
SECS/GEM Interface for K&S Ball Bonders
Bonder software version x-xx-x-473-series
ECID
(U2)
1094
1095
1096
1097
1098
1099
1100
IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Equipment Constants
Name
Type
Description
EC_WireCtrlStopSt
ate
EC_WireCtrlStopSit
e
EC_WireCtrlStopWi
re
EC_WireCtrlStopAc
tion
EC_UsgImpedance
HHLimit
EC_UsgImpedance
HLLimit
Process Program
Write Protect
U1[1]
Stop Control Mode. (0 = OFF; 1 = ONCE; 2 = ALWAYS)
U2[1]
Stop Device.
U2[1]
Stop Wire.
BL[1]
Action After Stop. (0 = NONE; 1 = GOTO SEQ STOP)
U1[1]
USG impedance high frequency high limit
U1[1]
USG impedance high frequency low limit.
BL[1]
Flag used to indicate that the process program name and its
components residing on equipment should not be overwritten by
the host downloading a program with the same name or
component name.
TRUE = enable write protect
FALSE = disable write protect
Maximum size, in bytes, of a concatenated process program
that can be uploaded to host without being compressed. Set to
zero (0) to disable compression. NOTE: On download, the
equipment automatically detects whether a process program is
compressed and reads it accordingly.
Storage device where the process program is stored.
0 = DISK
1 = RAM
Storage device where the process program will be stored.
0 = DISK
1 = RAM
2 = DISK & RAM
3 = RAM without MHS
Enable/disable Process program verification. (0 = OFF, 1 = ON)
1101
Process Program
Compression
Threshold
U4[1]
1102
Upload
Device
Source
I4[1]
1103
Download
Device
Target
I4[1]
1104
KGemPP_EC_PP_
Verify
EC_AutoUsgCal
I4[1]
EC_UsgAutoCalSc
anMode
EC_UsgAutoCalSc
anInterval
EC_LinktestInterval
U1[1]
EC_PrivAutoUsgCa
lOnOff
EC_PbiNSOPEvalu
ationState
EC_PbiBallAssocSt
ate
EC_KgemPBIBallId
EC_PbiBallNSOPE
valuationState
EC_PbiNSOPStop
Mode
BL[1]
Link test interval. UNIT: Seconds.
(MIN = 0; DEFAULT = 0; MAX = 120)
Master enable switch for USG impedance monitor feature.
BL[1]
PBI: NSOP evaluation state
BL[1]
PBI: ball association state
U1[1]
BL[1]
PBI: ball id
PBI: ball NSOP evaluation state(0 = OFF, 1 = ON)
BL[1]
PBI: NSOP stop mode (0 = OFF, 1 = ON)
1105
1106
1107
1108
1109
1111
1112
1113
1115
1116
BL[1]
U4[1]
U1[1]
Enable/disable Auto periodic USG calibration. (0 = OFF, 1 =
ON)
USG Auto scan mode. (0 = After device, 1 = After
leadframe/strip)
Scan interval during Auto periodic USG calibration.
Page - 154 - of 324
Jan 28, 2021 Rev 4.2
Kulicke & Soffa™
SECS/GEM Interface for K&S Ball Bonders
Bonder software version x-xx-x-473-series
ECID
(U2)
1117
1118
1119
1120
1121
1122
1123
1124
1125
1126
1127
1128
1129
1130
1131
1132
1133
1134
1135
1136
1137
1138
1140
1141
1142
1145
1146
IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Equipment Constants
Name
Type
Description
EC_PBIDelayBefor
eFirstCapture
EC_StripInject
EC_AutoIndex
EC_EFO_Current_
Offset
EC_EFO_Wand_lif
etime
EC_LoopHeightSca
leFactor
EC_LoopHeightOffs
et
EC_BondForceOffs
et
EC_Tool_Change_
Setting
EC_Tool_Usage_S
etting
EC_Cover_Gas_Co
ntrol_Type
EC_Save_PP_to_C
U2[1]
PRS delay before PBI inspection per bond
BL[1]
BL[1]
F4[1]
Enable/disable strip inject. (0 = OFF, 1 = ON)
Enable/disable auto index. (0 = OFF, 1 = ON)
Change EFO Current Offset
F4[1]
EFO wand life time checking
F4[1]
Loop Height Scale Factor
F4[1]
Loop Height Offset
I4[1]
Bond Force Offset
U1[1]
EC_Load_PP_Opti
on
EC_Wire_Lifetime
EC_Auto_Logoff_Pr
ivilege_User
EC_Priv_Level
U1[1]
EC_ClearFADataB
utton
EC_User_ID_Priv_
Level
BL[1]
Tool Change Setting
0=Normal/1=Lockout/2=Forced
Tool Usage Setting
0=PP/1=MDP
Cover gas control type
0=Manual/1=ON_OFF
Save PP to C option
0=Not Allowed/1=Allowed.
Load PP by file name or long name
0=Load by file name/1=Load by long name
Control wire life time setting
Auto Logoff Privilege User
0=OFF/1=ON
Privilege level
1=Anyone/2=Operator/3=Supervisor/4=Administrator
Enable/Disable clear FA data button
EC_AutoJogInMag
Ctrl
EC_AccessViolatio
nContCtrl
EC_AutomationJob
Ctrl
EC_LoadPPMethod
EC_DefaultWireCla
mpProfile
EC_FocusAdjState
EC_FocusAdjLimit
EC_PART_RECEIV
E_WAIT_TIME
EC_PART_EJECT_
WAIT_TIME
U1[1]
User ID Privilege Level
1=Anyone/2=Operator/
3=Supervisor/4=Engineer/
5=Administrator
Control of auto jogging magazine
U1[1]
Control of continue option support in access violation alarm
U1[1]
Control of automation job support
U1[1]
U1[1]
BL[1]
U2[1]
U4[1]
Control how to load process program for Next Job
Control option setting of Default Wire Clamp Profile 0=Standard/
1=Gentle/2=Super Gentle
Focus Adjustment State ON/OFF
Change in Focus Adjustment Limit
Part missing timer
U4[1]
Part jam timer
U1[1]
U1[1]
U1[1]
F4[1]
U1[1]
U1[1]
U1[1]
Page - 155 - of 324
Jan 28, 2021 Rev 4.2
Kulicke & Soffa™
SECS/GEM Interface for K&S Ball Bonders
Bonder software version x-xx-x-473-series
ECID
(U2)
1147
1148
1149
1150
1151
1152
1153
1154
1155
1156
1157
1158
1159
1160
1161
1162
1163
1164
1165
1166
1167
1170
1171
1172
1173
1174
IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Equipment Constants
Name
Type
Description
EC_MES_CTRL
U1[1]
EC_PPSelectMode
EC_Host_Reply_Ti
meout
EC_MotorStopTime
BeforePowerSave
EC_MotorStopTime
BeforeBonding
EC_MotorStopPow
erSaveConfig
EC_MotorStopHeat
ers
EC_MotorStopIllumi
nation
EC_MotorStopAirG
uide
EC_MotorStopMoni
tor
EC_MotorStopBlow
erKit
EC_Illumination
EC_BlowerKit
EC_XRegSeekAuto
RetryCount
EC_XRegSeekAuto
RetryDistance
EC_P1_AccessMod
e
EC_P2_AccessMod
e
EC_P3_AccessMod
e
EC_P4_AccessMod
e
EC_AUTO_LOGOF
F_TIME
EC_PRD_TIME_G
RACE_PERIOD
EC_Opr_Align_Pos
_Limit_Check_Stat
e
EC_Die_Opr_Align
_Pos_Limit
EC_LeadSub_Opr_
Align_Pos_Limit
EC_Substrate_Info
_Display_Name
EC_Substrate_Info
_Data
I4[1]
U1[1]
MES control
0 = disable
1 = enable
Process program select mode
Request Mag ID timeout
U4[1]
Change in MotorStopTimeBeforePowerSave
U4[1]
Change in MotorStopTimeBeforeBonding
BL[1]
MotorStopPowerSaveMode ON/OFF
BL[1]
MotorStopHeaters Yes/No
BL[1]
MotorStopIllumination Yes/No
BL[1]
MotorStopAirGuide Yes/No
BL[1]
MotorStopMonitor Yes/No
BL[1]
MotorStopBlowerKit Yes/No
BL[1]
BL[1]
U4[1]
Illumination Yes/No
BlowerKit Yes/No
X registration extra retry count
U4[1]
X registration extra retry distance
U1[1]
Access mode of input load tray
U1[1]
Access mode of output unload tray
U1[1]
Access mode of input unload tray
U1[1]
Access mode of output load tray
I4[1]
ECID for auto logoff privilege user time
I4[1]
BL[1]
ECID for production time grace period, which is the time from
engineering mode to production mode.
Operator align position limit check state
F4[1]
Die reference system operator align position limit
F4[1]
Lead/Substrate reference system operator align position limit
A[15]
The sub info display name in GUI
A[80]
The substrate information data
Page - 156 - of 324
Jan 28, 2021 Rev 4.2
Kulicke & Soffa™
SECS/GEM Interface for K&S Ball Bonders
Bonder software version x-xx-x-473-series
ECID
(U2)
1175
1176
1177
1178
1179
1180
1181
1182
1186
1187
1188
1189
1190
1191
1192
1193
1194
1195
1196
1197
1198
IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Equipment Constants
Name
Type
Description
EC_AllowLoadPPW
OMHS
EC_LoadPPWithTe
mperature
EC_PBIBondsWith
LowScore
EC_LoadPPWithInd
exEyePoint
EC_InhibitAutoRun
WithoutConv
EC_Save_Real_Ti
me_3rd_Opt_Image
s_State
EC_Save_Real_Ti
me_3rd_Opt_Image
s_Format
EC_Keep_Real_Ti
me_3rd_Opt_Image
s_After_Upload
EC_Reteach_DIE_
EP_Pos_Limit_Tol_
X
EC_Reteach_DIE_
EP_Pos_Limit_Tol_
Y
EC_Reteach_LEAD
_EP_Pos_Limit_Tol
_X
EC_Reteach_LEAD
_EP_Pos_Limit_Tol
_Y
EC_Reteach_SUB_
EP_Pos_Limit_Tol_
X
EC_Reteach_SUB_
EP_Pos_Limit_Tol_
Y
EC_USG_LF_Engr
_Current_Offset
EC_USG_HF_Engr
_Current_Offset
EC_USG_LF_Curre
nt_Factor
EC_USG_HF_Curr
ent_Factor
EC_USG_LF_Mach
ine_Current_Offset
EC_USG_HF_Mac
hine_Current_Offse
t
EC_UsgImpedance
LHLimit
U1[1]
Allow Load PP Without MHS
U1[1]
Load PP with temperature
U1[1]
PBI bonds with low score control option
U1[1]
Load PP with index eye point settings
U1[1]
Inhibit auto run without auto minor conversion
BL[1]
Real Time 3rd Opt Images Save State
U1[1]
Real Time 3rd Opt Images Save Format
BL[1]
EC_Keep_Real_Time_3rd_Opt_Images_After_Upload
F4[1]
Position limit tolerance of x coordinator during die eye point
reteach
F4[1]
Position limit tolerance of y coordinator during die eye point
reteach
F4[1]
Position limit tolerance of x coordinator during lead eye point
reteach
F4[1]
Position limit tolerance of y coordinator during lead eye point
reteach
F4[1]
Position limit tolerance of x coordinator during substrate eye
point reteach
F4[1]
Position limit tolerance of y coordinator during substrate eye
point reteach
F4[1]
Low USG Engineer voltage offset
F4[1]
High USG Engineer voltage offset
F4[1]
USG Low Frequency Current Factor
F4[1]
USG High Frequency Current Factor
F4[1]
USG Low Frequency voltage offset
F4[1]
USG High Frequency voltage offset
U2[1]
USG impedance low frequency high limit.
Page - 157 - of 324
Jan 28, 2021 Rev 4.2
Kulicke & Soffa™
SECS/GEM Interface for K&S Ball Bonders
Bonder software version x-xx-x-473-series
ECID
(U2)
1199
IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Equipment Constants
Name
Type
Description
U1[1]
USG impedance low frequency low limit.
1200
EC_UsgImpedance
LLLimit
Using HSMS
I4[1]
1201
1202
1203
1204
1205
1206
1207
1208
1211
T1
T2
T3
T4
T5
T6
T7
T8
BaudRate
I4[1]
I4[1]
I4[1]
I4[1]
I4[1]
I4[1]
I4[1]
I4[1]
I4[1]
1212
1213
RetryLimit
ConnectWait
I4[1]
I4[1]
1214
DetectDuplicate
I4[1]
1215
ActiveMode
I4[1]
1216
RemoteAddress
A[40]
1217
RemotePort
I4[1]
1218
LocalPort
I4[1]
1219
CommPort
A[40]
1220
Machine IP Address
A[15]
1221
GatewayInet
A[15]
1222
TargetName
A[19]
1223
1224
1225
1226
HostName
HostIP
SubnetMask
KgemBtnPwd
A[19]
A[15]
A[15]
A[12]
Flag used to indicate that HSMS will be used by equipment for
SECS2 communications. Host read-only. When changed by
operator, requires equipment to be rebooted to take effect.
FALSE = use SECS 1
TRUE = use HSMS
SECS-I Inter-Character Timeout(see section 5)
SECS-I Protocol Timeout(see section 5)
SECS-I/HSMS Reply Timeout(see section 5)
SECS-I Inter-Block Timeout(see section 5)
HSMS Connect Separation Timeout(see section 5)
HSMS Control Transaction Timeout(see section 5)
HSMS Not Selected Timeout(see section 5)
HSMS Network Inter-Character Timeout(see section 5)
SECS-I serial line speed. Host read-only. When changed by
operator, requires equipment to be rebooted to take effect.
SECS-I retry limit.
Number of seconds equipment’s HSMS should wait to establish
a TCP/IP connection.
Flag used to indicate if SECS1 should check for duplicate blocks
when receiving multi-block messages.
HSMS Connect Mode. Host read-only. When changed by
operator, requires equipment to be rebooted to take effect.
IP address or IP host name of Host. Host read-only. When
changed by operator, requires equipment to be rebooted to take
effect.
TCP/IP Port used by host. Host read-only. When changed by
operator, requires equipment to be rebooted to take effect.
TCP/IP port used by equipment. Host read-only. When changed
by operator, requires equipment to be rebooted to take effect.
Name of equipment’s serial device. Host read-only. When
changed by operator, requires equipment to be rebooted to take
effect.
IP Address used by equipment. Host read-only. When changed
by operator, requires equipment to be rebooted to take effect.
The internet address of the gateway through which to boot, if
the host is not on the same network as the target(gateway
inet(g) in Bootline). When changed by the operator, requires
equipment to be rebooted to take effect.
Target name (tn) in BootLine. This the bonder's host name.
When changed by the operator, requires equipment to be
rebooted to take effect.
The name of the host to boot from.
The Internet address of the host to boot from.
Mask used to correctly access the host
Password for accessing the Communication and Control State
dialogs.
Page - 158 - of 324
Jan 28, 2021 Rev 4.2
Kulicke & Soffa™
SECS/GEM Interface for K&S Ball Bonders
Bonder software version x-xx-x-473-series
ECID
(U2)
1227
IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Equipment Constants
Name
Type
Description
LoadDefBootParms
BL[1]
EC_EnablePrimary
BondParm
EC_AutoUnclamp
BL[1]
EC_RegripLeadfra
me
EC_RehomeZ
EC_PowerFailReco
very
EC_PFRInterval
EC_MotionAfterYS
ensorSetup
BL[1]
When set to TRUE, factory default settings for host name,
machine IP address, host IP, gateway IP address, and target
name.
Note: The equipment constant is always set to FALSE every
time the Modify Equipment Constant dialog is displayed.
Enable/Disable the primary bond parameter update. (0 = OFF,
1 = ON)
Setting for auto unclamp mode
0=OFF/1=AutoStateOnly/2=Auto&IdleState
Turn the Regrip Leadframe ON/Off
BL[1]
BL[1]
Turn on/off the Rehome Z magazine
Power fail recovery mode
U2[1]
BL[1]
BL[1]
F4[1]
U1[1]
Request PP List from host has timed out
BL[1]
Auto Correct Ref.Sys Xhair Delta Feature Enabled/Disabled
U1[1]
U4[1]
1332
EC_GUI_PP_Prote
ct
EC_Auto_Unclamp
_Timeout
Req_PP_List_Time
out
EC_AutoCorrectRef
SysXhairDelta
EC_NegYPullOffset
ProdReportThresho
ld
EC_AutoClearFAD
ataOnPage1
EC_AutoClearFAD
ataOnPage2
EC_AutoClearFAD
ataOnPage3
UserEC1
Power fail recovery interval(minutes).
Calibrated / Manual option.
255 = Calibrated,
0 = Manual
Control permission to overwrite existing Long and / or Short
Program Filenames when using the bonder GUI.
ECO Auto Unclamp time
1333
UserEC2
A[15]
1334
UserEC3
A[15]
1377
EC_UserEC23
BL[1]
1378
EC_UserEC24
BL[1]
1379
EC_UserEC25
BL[1]
Magazine y direction configuration, normal(0) or reverse(1).
Number
of
packages
to
be
processed
before
PACKAGE_THRESHOLD-REACHED collection event is sent.
Constant to show if “auto clear FA Data After Sent” feature for
page of operator manual data Entry #1 is enabled or disabled.
Constant to show if “auto clear FA Data After Sent” feature for
page of operator manual data Entry #2 is enabled or disabled.
Constant to show if “auto clear FA Data After Sent” feature for
page of operator manual data Entry #3 is enabled or disabled.
Operator Entry #1 dialog - 1st item string label.
Default = "Enter_Data_A"
Operator Entry #1 dialog - 2nd item string label.
Default = "Enter_Data_B"
Operator Entry #1 dialog - 3rd item string label.
Default = "Enter_Operator_"
Set the lock state of panel 1 on
“Operator Data Entry #2” dialog
FALSE: unlock the data entry
TRUE: lock the data entry
Set the lock state of panel 2 on
“Operator Data Entry #2” dialog
FALSE: unlock the data entry
TRUE: lock the data entry
Set the lock state of panel 3 on
“Operator Data Entry #2” dialog
FALSE: unlock the data entry
TRUE: lock the data entry
1239
1240
1241
1242
1243
1244
1245
1246
1247
1248
1250
1255
1300
1329
1330
1331
U1[1]
BL[1]
BL[1]
BL[1]
A[15]
Page - 159 - of 324
Jan 28, 2021 Rev 4.2
Kulicke & Soffa™
SECS/GEM Interface for K&S Ball Bonders
Bonder software version x-xx-x-473-series
ECID
(U2)
1380
IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Equipment Constants
Name
Type
Description
EC_UserEC26
BL[1]
1381
1382
1383
1384
1385
1386
1387
1388
1389
1390
1391
EC_UserEC13
EC_UserEC14
EC_UserEC15
EC_UserEC16
EC_UserEC17
EC_UserEC18
EC_UserEC19
EC_UserEC20
EC_UserEC21
EC_UserEC22
UserEC5
A[15]
A[15]
A[15]
A[15]
A[15]
A[15]
A[15]
A[15]
A[15]
A[15]
A[15]
1392
UserEC6
A[15]
1393
UserEC7
A[15]
1394
UserEC8
A[15]
1395
U1[1]
1398
EC_BITsAutoRecv
Shtl
EC_BITsAutoRecv
EFO
EC_FalseNSOP
1399
EC_TimeFormat
U1[1]
1401
EC_PreclampExpa
nsionOption
U1[1]
1402
EC_PreclampExpa
nsionTime
EC_MagEjectOpt
U4[1]
EC_CAP_CLEAN_
ENABLE
EC_CAP_CLEAN_
KWIRE
EC_CAP_CLEAN_
TOUCHDOWN
EC_TIP_For_CapCl
eaning
EC_CV_For_CapCl
eaning
EC_USG_Current_
For_CapCleaning
BL[1]
1396
1403
1404
1405
1406
1407
1408
1409
U1[1]
U1[1]
BL[1]
U2[1]
Set the lock state of panel 4 on
“Operator Data Entry #2” dialog
FALSE: unlock the data entry
TRUE: lock the data entry
Operator Entry #3 dialog - 1th item string label.
Operator Entry #3 dialog - 2th item string label.
Operator Entry #3 dialog - 3th item string label.
Operator Entry #3 dialog - 4th item string label.
Operator Entry #3 dialog - 5th item string label.
Operator Entry #3 dialog - 6th item string label.
Operator Entry #3 dialog - 7th item string label.
Operator Entry #3 dialog - 8th item string label.
Operator Entry #3 dialog - 9th item string label.
Operator Entry #3 dialog - 10th item string label.
Operator Entry #2 dialog - 1st item string label.
Default = "Enter_SV_3901"
Operator Entry #2 dialog - 2nd item string label.
Default = "Enter_SV_3092"
Operator Entry #2 dialog - 3rd item string label.
Default = "Enter_SV_3093"
Operator Entry #2 dialog - 4th item string label.
Default = "Enter_SV_3094"
BITS Dialog setting on auto recovery for Short Tail
0=OFF/1=ON
BITS Dialog setting on auto recovery for EFO
0=OFF/1=ON
Flag to turn on/off Backup for BITS NSOP
0=OFF/1=NSOP ON BALL/2=NSOP ON BUMP
System Time Format:
0 = 12 bytes: YYMMDDHHMMSS
1 = 16 bytes: YYYYMMDDHHMMSSCC
Expansion Compensation state:Preclamp expansion option
0 = OFF
1 = FIRST INDEX
2 = ALL INDEX
Preclamp expansion time
Enable/Disable “Eject Mag after Every PP Change”. (0 = OFF.,
1 = ON)
Cap cleaning enable/disable(=0/1)
F4[1]
Number of wires to be bonded before cap cleaning sequence is
triggered (x1000)
Number of cap touchdowns on the tape for each cap cleaning
sequence
Tip value for cap cleaning (same meaning as Bond parameter)
F4[1]
C/V value for cap cleaning (same meaning as Bond parameter)
F4[1]
USG current for cap cleaning (same meaning as Bond
parameter)
U2[1]
Page - 160 - of 324
Jan 28, 2021 Rev 4.2
Kulicke & Soffa™
SECS/GEM Interface for K&S Ball Bonders
Bonder software version x-xx-x-473-series
ECID
(U2)
1410
IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Equipment Constants
Name
Type
Description
EC_USG_Time_Fo
r_CapCleaning
EC_Bond_Force_F
or_CapCleaning
EC_Contact_Thres
hold_For_CapClea
ning
EC_USG_Prebleed
_For_CapCleaning
EC_PM_TimeForm
at
F4[1]
USG time for cap cleaning (same meaning as Bond parameter)
F4[1]
Bond force for cap cleaning (same meaning as Bond parameter)
U1[1]
Contact threshold for cap cleaning (same meaning as Bond
parameter)
U1[1]
BL[1]
U1[1]
VLL foreign material detection area tolerance.
1417
EC_PM_VLLFMDE
TECTED
EC_PM_VLLFMAR
EATOL
EC_LTO_Green
USG Pre-bleed for cap cleaning (same meaning as Bond
parameter)
Define production monitoring (PM) time format.
0 = : Support yyyymmddhhmmss (14 characters).
1 = : Support yyyymmddhhmmsscc (16 characters).
It takes effect after machine reboot.
VLL foreign material detection setting for MTBA calculation.
U1[1]
1418
EC_LTO_Yellow
U1[1]
1419
EC_LTO_Red
U1[1]
1420
1421
1422
EC_Pusher_Kit
CfgAuto_Eye_Pts
CfgAuto_Contact_S
urface
CfgAuto_VLL
CfgAuto_VLL_Asso
c
CfgAuto_Backup_E
ye_Pts
CfgAuto_Indexing
CfgAuto_EFO
CfgAuto_Operator_
Pts
CfgAuto_Temp_Ala
rm
CfgAuto_Alarm_Co
nfig
CfgAuto_Temp_Err
or
CfgAuto_VLL_Tip_
Find
Auto_Run_Mode
BL[1]
BL[1]
BL[1]
Green light tower settings
0=off/1=on/2=flash
Yellow light tower settings
0=off/1=on/2=flash
Red light tower settings
0=off/1=on/2=flash
Pusher Kit configuration
Eye Points
Contact_Surface surface
BL[1]
BL[1]
VLL surface setting on Dry cycle
VLL_Assoc surface setting on Dry cycle
U1[1]
Backup_Eye Points
U1[1]
BL[1]
BL[1]
Indexing 0/Normal 1/Manual 2/Dry 3/Skip
EFO 0=off /1=on
Operator Points 0=off /1=on
BL[1]
Temperature Alarm 0=off /1=on
BL[1]
Temp_ Alarm_ Config 0=off /1=on
BL[1]
Delayed Temp_ Error 0=off /1=on
BL[1]
VLL_ Tip_ Find 0=off /1=on
BL[1]
EC_GEMButtonsEn
abled
EC_OfflineTimeBef
oreInhibitAuto
EC_ProcessErrors
EC_VisionErrors
BL[1]
Run Mode:
0/Dry Cycle 1/Auto Run
GEM buttons configuration.
U2[1]
Offline time (in seconds) before inhibit auto.
U4[1]
U4[1]
Process errors
Vision errors
1411
1412
1413
1414
1415
1416
1423
1424
1425
1426
1427
1428
1429
1430
1431
1432
1433
1434
1435
1436
1437
U1[1]
Page - 161 - of 324
Jan 28, 2021 Rev 4.2
Kulicke & Soffa™
SECS/GEM Interface for K&S Ball Bonders
Bonder software version x-xx-x-473-series
ECID
(U2)
1438
1439
IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Equipment Constants
Name
Type
Description
EC_MaterialErrors
EC_WorkholderErr
ors
EC_MaghandlerErr
ors
CfgRun_BITS
CfgRun_Wire_Feed
_Error
CfgRun_VLL
CfgRun_VLL_Asso
c
CfgRun_Backup_E
ye_Pts
CfgRun_Indexing
CfgRun_Temp_Alar
m_Config
CfgRun_Delayed_T
emp_Error
CfgRun_VLL_Tip_F
ind
EC_VLL_Delay
EC_Prs_Die_Delay
EC_Prs_Lead_Dela
y
EC_Backup_PRS_
NSOP
EC_NSOPNotify
EC_NSOLNotify
EC_SHTLNotify
EC_PRSNSOPWire
AngleCheck
EC_TOOL_VALIDA
TION
U4[1]
U4[1]
Material errors
Work holder errors
U4[1]
Magazine handler errors.
BL[1]
BL[1]
BITS setting on Auto Run
Wire_ Feed_ Error on Auto Run Configuration Dialog.
BL[1]
BL[1]
VLL on Auto Run Configuration Dialog.
VLL Association on Auto Run Configuration Dialog.
U1[1]
Backup_ Eye Points on Auto Run Configuration Dialog.
BL[1]
BL[1]
Indexing 0/Normal 1/Manual on Auto Run Configuration Dialog.
Temp_Alarm_Config setting on Auto Run
BL[1]
Delayed_Temp_Error setting on Auto Run
BL[1]
VLL_ Tip_ Find on Auto Run Configuration Dialog.
F4[1]
F4[1]
F4[1]
VLL Delay
PRS Delay for Die Eye Point
PRS Delay for Lead Eye Point
U4[1]
Backup PRS NSOP BITS error auto recovery
BL[1]
BL[1]
BL[1]
U1[1]
BITS Configuration: NSOP Notify 0=off /1=on
BITS Configuration: NSOL Notify 0=off /1=on
BITS Configuration: SHTL Notify 0=off /1=on
Change in PRS NSOP Wire Angle Check
U1[1]
1461
EC_WIRE_VALIDA
TION
U1[1]
1462
EC_DFLT_PART_I
D
EC_LTO_White
EC_LTO_Blue
EC_USGCleanVolt
EC_USGFreqSelec
tion
EC_ForceBondHtR
elrn
EC_MinWireThresh
old
EC_WireUsageTim
er
EC_TimerDuration
A[80]
Tool validation enables flag
0 = disable
1 = enable
Wire validation enables flag
0 = disable
1 = enable
Default part Id
U1[1]
U1[1]
U2[1]
U1[1]
White light tower settings 0=off/1=on/2=flash
Blue light tower settings 0=off/1=on/2=flash
USG clean voltage
USG high and low frequency selection
U1[1]
Force bond height to relearn if enable
F4[1]
U1[1]
Wire spool should be changed if remaining wire length less than
min wire threshold
Turn on/off wire usage with timer
U2[1]
Time duration for change wire spool
1440
1441
1442
1443
1444
1445
1446
1449
1450
1451
1452
1453
1454
1455
1456
1457
1458
1459
1460
1470
1471
1481
1482
1483
1484
1485
1486
Page - 162 - of 324
Jan 28, 2021 Rev 4.2
Kulicke & Soffa™
SECS/GEM Interface for K&S Ball Bonders
Bonder software version x-xx-x-473-series
ECID
(U2)
1487
1488
1489
1490
1491
1492
1500
1501
1502
1503
1504
1505
1506
1507
1508
1509
1510
1511
1512
1513
1514
1515
1516
1517
1518
1519
1520
1521
1522
IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Equipment Constants
Name
Type
Description
EC_StopBondingAft
er
EC_WireUsageInfo
MinSample
EC_WireUsageDisp
lay
EC_WireSpoolDiam
eter
EC_InitialBondCou
nt
EC_InitialHoursInU
se
PM Data Update
Mode
PM_StartTime
PM_StopTime
EC_Lot_StartTime
EC_PM_StartTime
EC_PM_EndTime
EC_PreclampExpa
nsionClamp
EC_PreclampHBOff
set
EC_ToolPNInfo
EC_WirePNInfo
EC_FalseNSOL
EC_LOT_CONTRO
L_TRACKING
EC_WireUsageUnit
EC_ConnInhibitAut
oOption
U1[1]
When wire expired, stop at finish device, index, or strip
U1[1]
U1[1]
Min sample index bonded, then can display wire usage
information
Switch to show wire usage, OFF/Wire Remaining/ Wire Used
F4[1]
Wire spool diameter
U4[1]
Initial bond count when start bond
U4[1]
Initial used hours when start bond
U1[1]
I4[1]
Update PM SV data Mode 0 = HOST RCMD
1 = Bonder GUI
Start time for logged data analysis, format yyyymmddhhmmss.
Stop time for logged data analysis, format yyyymmddhhmmss.
Lot Start Time.
The Start Time of PM data summary in bonder side
The End Time of PM data summary in bonder side
Preclamp expansion clamp
0=OPEN/1= CLOSE
Preclamp HB Offset
A[33]
A[33]
BL[1]
BL[1]
Capillary Serial or Part number
Wire Serial or Part number
Flag to turn on/off Backup for BITS NSOL. (0 = OFF, 1 = ON)
Flag to turn on/off Lot Control Tracking. (0 = OFF, 1 = ON)
U4[1]
U2[1]
EC_Map_Column_
Compacted
CfgMagID_IMH_St
ate
CfgMagID_IMH_Fai
lOP
CfgMagID_IMH_De
faultBcr
CfgMagID_IMH_Val
idOp
CfgMagID_IMH_Re
try
CfgMagID_OMH_St
ate
CfgMagID_OMH_F
ailOP
CfgMagID_OMH_D
efaultBcr
BL[1]
Wire Usage Unit configuration. (0=DEVICE/1=INDEX)
Option for Connectivity Inhibit Auto option (Read Only):
Bit 1 = Comm Down.
Bit 2 = Control Offline.
Bit 3 = Control Local.
Flag to turn on/off strip map column compact mode. (0 = OFF,
1 = ON)
Configure Mag ID Input Mag Handler State
A[14]
A[14]
A[14]
A[14]
A[14]
U1[1]
BL[1]
U1[1]
A[80]
Configure Mag ID Input Mag Handler OP (0=ASK /1=Eject
/2=Eject and Stop / 3= Send Default Mag ID)
Configure Mag ID Input Mag Handler Default BCR
BL[1]
Configure Mag ID Input Mag Handler Valid OP
U1[1]
Configure Mag ID Input Mag Handler Retry (0= 0 times /1= 1
times /2= 2 times /3= 3 times)
Configure Mag ID Output Mag Handler State
BL[1]
U1[1]
A[80]
Configure Mag ID Output Mag Handler Fail OP (0=ASK /1=Eject
/2=Eject and Stop / 3= Send Default Mag ID)
Configure Mag ID Output Mag Handler Default BCR
Page - 163 - of 324
Jan 28, 2021 Rev 4.2
Kulicke & Soffa™
SECS/GEM Interface for K&S Ball Bonders
Bonder software version x-xx-x-473-series
ECID
(U2)
1523
1524
1525
1526
1527
1528
1529
1530
1531
1532
1533
1534
1535
1536
1537
1538
1540
1550
1551
1552
1553
1554
IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Equipment Constants
Name
Type
Description
CfgMagID_OMH_V
alidOp
CfgMagID_OMH_R
etry
OhtCtrlStatus
BL[1]
Configure Mag ID Output Mag Handler Valid OP
U1[1]
EC_OHT_Load_Ma
g_Benching_Kit_Ac
tion
EC_ARVState
B[1]
EC_ImhSlotScanSt
ate
EC_OmhSlotScanS
tate
EC_LoadPPNoInfo
Dialog
EC_UsgImpedance
DeltaCheck
EC_UsgImpedance
LDeltaForManualC
alibration
EC_UsgImpedance
HDeltaForManualC
alibration
EC_UsgImpedance
LDeltaForPeriodicS
can
EC_UsgImpedance
HDeltaForPeriodicS
can
EC_PreclampSeco
ndPrsCorrOption
EC_OutSlotLFDete
ctKitInstalled
EC_OutSlotLFDete
ctEnabled
EC_GEMMessage
CollectionEnabled
EC_SubReaderEna
ble
EC_SubIDValidatio
n
EC_GLOBAL_ID_V
ALIDATION_SWIT
CH_CHANGED
EC_ID_VALIDATIO
N_OFF_AT_COMM
DOWN
EC_ID_VALIDATIO
N_OFF_AT_CTRL_
OFFLINE
BL[1]
BL[1]
Configure Mag ID Output Mag Handler Retry (0= 0 times /1= 1
times /2= 2 times /3= 3 times)
OHT control Status
(TURE:OHT FALSE: STANDALONE)
Determine the benching kit action after OHT loads mag onto
loading tray. 0 means no action. 1 means that benching kit
extends and holds there after mag being loaded by OHT.
ARV state
(TRUE = enable; FALSE=disable)
True – Input mag slot scanning is enabled.
False – Input mag slot scanning is disabled
True – Output mag slot scanning is enabled.
False – Output mag slot scanning is disabled
Load PP Ignore Info Dialog
BL[1]
USG Impedance Delta Check
F4[1]
USG Impedance Low Delta For Manual Cal
F4[1]
USG Impedance High Delta For Manual Cal
F4[1]
USG Impedance Low Delta for Perioidc Scan
F4[1]
USG Impedance High Delta for Perioidc Scan
U1[1]
PreClamp Sencond PRS Correction Option
BL[1]
Constant to show if “out slot LF detection kit” is installed or not .
BL[1]
Constant to show if the “out slot LF detection” feature is enabled
BL[1]
GEM Log Msg Collection Enable/Disable
BL[1]
Substrate reader enables flag
BL[1]
Substrate reader validation enables flag
BL[1]
Global ID host validation switch changed
BL[1]
Set ID Validation switch when bonder in COMM-DOWN mode
BL[1]
Set ID Validation switch when bonder in CTRL-Offline mode
BL[1]
BL[1]
BL[1]
Page - 164 - of 324
Jan 28, 2021 Rev 4.2
Kulicke & Soffa™
SECS/GEM Interface for K&S Ball Bonders
Bonder software version x-xx-x-473-series
ECID
(U2)
1555
1556
1557
1558
1559
1560
1561
1562
1563
1564
1565
1566
1567
1568
1569
1570
1571
1572
1573
1574
1575
1576
1577
1578
IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Equipment Constants
Name
Type
Description
EC_ID_VALIDATIO
N_OFF_AT_CTRL_
LOCAL
EC_Input_Mag_Vali
dation_Reject_Opti
on
EC_Input_Mag_Vali
dation_Timeout
EC_Output_Mag_V
alidation_Reject_O
ption
EC_Output_Mag_V
alidation_Timeout
EC_Substrate_Vali
dation_Reject_Opti
on
EC_Substrate_Vali
dation_Timeout
EC_Dummy_State
Remote Selected
Log File
EC_StripMap_Dwnl
d_Src
StripMap_State
StripMap_Downloa
d_Mode
Output_CellStatus_
OutputGoodDev
Output_CellStatus_
InputDefectDev
Output_CellStatus_
RejectedDev
Output_CellStatus_
NotBondedDev
CellGrade_Mode
StripID_From_2D_
State
2D_Code_Reader_
State
2D_Force_Read_St
ate
BackupSubIDSearc
h
EC_Desirable_Strip
Map_Setting
EC_Cpu-And-OsFault-MonitorInterval
EC_Cpu-And-OsFault-MonitorEnable
BL[1]
Set ID Validation switch when bonder in CTRL-Local mode
U1[1]
Input Magazine On Validation Reject Option /0= error /1= stop
U1[1]
Input Magazine validation timeout
U1[1]
Output Magazine On Validation Reject Option /0= error /1= stop
U1[1]
Output Magazine validation timeout
U1[1]
Substrate validation Reject Option /0= error /1= stop
U1[1]
Substrate validation Timeout
U1[1]
A[81]
BL[1]
U1[1]
Dummy State Setting
Used to indicate which log file is selected for the log file
transferring via S13F3-S13F8.
The source of input strip map:
0=Machine/1=Host
Strip Map On/Off Setting
Strip Map Download Mode
U1[1]
Output Cell Status of output Good Device
U1[1]
Output Cell Status of Input Defect Device
U1[1]
Output Cell Status of Rejected Device
U1[1]
Output Cell Status of Not Bonded Device
U1[1]
BL[1]
Cell Grade Mode
Get Strip ID From 2D
BL[1]
2D Code Reader State
BL[1]
2D Force Read State
U1[1]
Backup substrate ID search type
U1[1]
Desirable Strip Map Setting
I4[1]
Interval to monitor for CPU and System Fault (in Seconds)
BL[1]
Flag to enable the monitoring for CPU and System Fault (in
Seconds
U1[1]
Page - 165 - of 324
Jan 28, 2021 Rev 4.2
Kulicke & Soffa™
SECS/GEM Interface for K&S Ball Bonders
Bonder software version x-xx-x-473-series
ECID
(U2)
1579
1580
1581
1582
1583
1584
1585
1586
1587
1588
1589
1590
1591
1592
1593
1594
1595
1596
1597
1600
1601
1602
1603
1604
1605
1606
IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Equipment Constants
Name
Type
Description
EC_StripMap_Unde
sired
_Setting_Inhibit_Au
to
OHT_Insp_Mode_S
tatus
OHT_Input_Load_T
imeout
OHT_Input_Unload
_Timeout
OHT_Output_Load
_Timeout
OHT_Output_Unloa
d_Timeout
EC_OHT_Load_Tra
y_Benching
EC_OHT_Unoad_T
ray_Belting
EC_IndexEyeExten
dSearch
EC_SKIP_BITS_LE
ARN_PROMPT
EC_CM_Log_State
EC_StripMapLoadF
rom
EC_StripMapPPDef
ault
EC_MAP_DOWNL
OAD_ORIENTATIO
N
EC_MAP_UPLOAD
_ORIENTATION
EC_InputStripMapC
ells
EC_InputCellGrade
OnAssist
EC_UnknownDevCt
lOption
EC_CellGradeForm
at
EC_INPUT_BARC
ODE_READER
EC_OUTPUT_BAR
CODE_READER
EC_2D_CODE_RE
ADER
EC_EFOPMEnable
EC_EFOCleaningIn
terval
EC_CmLogInterval
EC_StripIDReadLo
adFrom
U1[1]
When enable Undesired Setting Inhibit Auto, it will inhibit auto
bonding if strip map configuration doesn't match the
desire.Default is Disabled.
BL[1]
OHT Insp Mode Status
U2[1]
OHT input loading timeout delay
U2[1]
OHT input unloading timeout delay
U2[1]
OHT output loading timeout delay
U2[1]
OHT output unloading timeout delay
BL[1]
OHT loading tray benching option
BL[1]
OHT output mag unload tray belting config
BL[1]
State of extend search of index eye point
U1[1]
Control of prompt of BITS Learn related
BL[1]
U1[1]
Control of common log file function
Configure where to load Strip Map configuration
U1[1]
Default Strip Map setting for PP
U2[1]
Change the download map orientation
U2[1]
Change the upload map orientation
U1[1]
Input strip map data
BL
Input Cell Grade On Assist
BL
Unknown Device control option
U1[1]
Cell grade format
A[30]
Input Barcode Reader
A[30]
Output Barcode Reader
A[30]
2D Code Reader
U4[1]
U4[1]
EFO Preventive Maintenance enable
EFO Cleaning Interval
U4[1]
U1[1]
Interval for common log file saving
Configure where to load strip ID read state setting, MDP or PP
Page - 166 - of 324
Jan 28, 2021 Rev 4.2
Kulicke & Soffa™
SECS/GEM Interface for K&S Ball Bonders
Bonder software version x-xx-x-473-series
ECID
(U2)
1607
1612
1613
1614
1615
1616
1617
1618
1619
1620
1621
1622
1623
1626
1627
1628
1708
IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Equipment Constants
Name
Type
Description
EC_StripIDReadPP
Default
EC_TempZone1Set
Point
EC_TempZone1Off
set
EC_TempZone1Tol
erance
EC_TempZone1On
Off
EC_TempZone2Set
Point
EC_TempZone2Off
set
EC_TempZone2Tol
erance
EC_TempZone2On
Off
EC_TempZone3Set
Point
EC_TempZone3Off
set
EC_TempZone3Tol
erance
EC_TempZone3On
Off
EC_showOHTPaus
eWarningWhl
EC_showOHTPaus
eWarningMag
EC_skipLimitCheck
Option
EC_PrivControlMod
e
U1[1]
I2[1]
Default strip ID read state setting for loading strip ID read from
PP when no PP is loaded.
Set temperature zone1 preheat setpoint value
I2[1]
Set temperature zone1 preheat offset value
I2[1]
Set temperature zone1 preheat tolerance value
U1[1]
Turn temperature zone1 preheat on/off
I2[1]
Set temperature zone2 bondsite setpoint value
I2[1]
Set temperature zone2 bondsite offset value
I2[1]
Set temperature zone2 bondsite tolerance value
U1[1]
Turn temperature zone2 bondsite on/off
I2[1]
Set temperature zone3 postheat setpoint value
I2[1]
Set temperature zone3 postheat offset value
I2[1]
Set temperature zone3 postheat tolerance value
U1[1]
Turn temperature zone3 postheat on/off
U1[1]
Show OHT pause warning option for WHL (0 – no, 1 -yes)
U1[1]
U1[1]
Show OHT pause warning option for magazine handler (0 – no,
1 -yes)
Allow skip xhair offset limit check once.
U1[1]
Set/Get Privilege Password Control Setting.
0: Access Level
1: User Identification
LHM enable
(F=Off, T=On)
Target Loop ID for associated GEM operations
1749
EC_LHM_STATE
BL[1]
1751
EC_LHM_GEM_LO
OP_ID
EC_LHM_GEM_M
EASURE_TYPE
EC_LHM_LIMIT_M
ETHOD
EC_LHM_ERROR_
LIMIT_ACTIVE
U1[1]
EC_LHM_ERROR_
UPPER_LIMIT
EC_LHM_ERROR_
LOWER_LIMIT
F4[1]
Target Measurement Type for associated GEM operations
(0=Max Loop Height, 1=Edge Height
Limit Method to use for targeted Loop ID and Limit Type
(0=Off, 1=User Defined)
Error limit control of targeted Loop ID and Limit Type
(0=Off, 1=Both,
2=Upper Only,
3=Lower Only)
Upper error limit of targeted Loop ID and Limit Type
F4[1]
Lower error limit of targeted Loop ID and Limit Type
1753
1754
1758
1759
1760
U1[1]
U1[1]
U1[1]
Page - 167 - of 324
Jan 28, 2021 Rev 4.2
Kulicke & Soffa™
SECS/GEM Interface for K&S Ball Bonders
Bonder software version x-xx-x-473-series
ECID
(U2)
1761
1762
1763
1764
1765
1770
1771
1780
1781
1782
1783
1784
1785
1786
1787
1788
1789
1790
1791
1792
1793
1794
1795
IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Equipment Constants
Name
Type
Description
EC_LHM_RESULT
_VALIDATION_ST
ATE
EC_LHM_RESULT
_VALIDATION_RE
JECT_OPTION
EC_LHM_MAX_LO
OP_HEIGHT_MEA
S_CODE
EC_LHM_EDGE_H
EIGHT_MEAS_CO
DE
EC_LHM_LIMIT_C
ONTROL_TYPE
EC_LHM_SAMPLI
NG_UNIT
EC_LHM_SAMPLI
NG_INTERVAL
EC_WireInspState
BL[1]
Measurement result validation enable
U1[1]
Measurement result validation Reject Option
(0=Error, 1=Stop)
A[20]
Code for maximum loop height measurement
A[20]
Code for edge height measurement
U1[1]
U1[1]
Limit Type to use for targeted Loop ID
(0=Absolute, 1=Relative)
LHM sampling unit (0=Index, 1=Strip, 2=Mag)
U4[1]
LHM sample every N units
BL[1]
EC_WireInspBrkPnt
sEnabled
EC_WireInspAssoc
State
EC_WireInspRealig
nState
EC_ReqMeasurePe
rWireInsp
EC_TriesPerWireIn
spMax
EC_WireInspFailSt
opMode
EC_WireInspPeriod
icSamplingState
EC_WireInspSampl
ingIntervalUnit
EC_WireInspSampl
ingInterval
EC_WireInspTrigge
rOnToolChangeStat
e
EC_WireInspTrigge
rOnWireSpoolChan
geState
EC_WireInspTrigge
rOnStartAutoRunSt
ate
EC_KgemWireInspI
d
EC_WireInspLimitM
ethod
EC_WireInspErrorLi
mitUpperState
BL[1]
Wire Inspection:
Enabled state
Wire Inspection:
Breakpoint enabled state
Wire Inspection:
Association enabled state
Wire Inspection:
Realign before inspection enabled state
Wire Inspection:
Required measurement per wire inspection (value >= 1)
Wire Inspection:
Maximum tries per wire (value >= 1)
Wire Inspection:
Fail stop mode
Wire Inspection:
Periodic sampling state
Wire Inspection:
Sampling interval unit. 0- Device, 1-Index
Wire Inspection:
Sampling interval number
Wire Inspection:
Trigger on tool change state
BL[1]
BL[1]
U1[1]
U1[1]
B[1]
BL[1]
B[1]
U2[1]
BL[1]
BL[1]
Wire Inspection:
Trigger on wire spool change state
BL[1]
Wire Inspection:
Trigger on start auto run state
U1[1]
Wire Inspection:
Wire inspection ID
Wire Inspection:
Limit method, 0-Off, 1-User Define
Wire Inspection:
Error limit upper state
B[1]
BL[1]
Page - 168 - of 324
Jan 28, 2021 Rev 4.2
Kulicke & Soffa™
SECS/GEM Interface for K&S Ball Bonders
Bonder software version x-xx-x-473-series
ECID
(U2)
1796
IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Equipment Constants
Name
Type
Description
F4[1]
1822
EC_WireInspErrorLi
mitUpper
EC_WireInspWarnL
imitUpperState
EC_WireInspWarnL
imitUpper
UserEC4
1891
UserEC9
A[30]
1892
UserEC10
A[30]
1893
UserEC11
A[30]
1894
UserEC12
A[30]
1797
1798
BL[1]
F4[1]
A[30]
Wire Inspection:
Error limit upper value
Wire Inspection:
Warn limit upper state
Wire Inspection:
Warn limit upper value
Operator Entry #1 dialog - 4th item
Default = "Send_Operator_Event"
Operator Entry #2 dialog - 5th item
Default = "Send_CE_8091"
Operator Entry #2 dialog - 6th item
Default = "Send_CE_8092"
Operator Entry #2 dialog - 7th item
Default = "Send_CE_8093"
Operator Entry #2 dialog - 8th item
Default = "Send_CE_8094"
string label.
string label.
string label.
string label.
string label.
Figure 59 – K&S Model Power Series Automatic Ball Bonder and K&S Model Gen-S Automatic Ball Bonder
Shared Equipment Constants
Page - 169 - of 324
Jan 28, 2021 Rev 4.2
Kulicke & Soffa™
SECS/GEM Interface for K&S Ball Bonders
Bonder software version x-xx-x-473-series
6.4
K&S Model Power Series Automatic Ball Bonder and K&S Model Gen-S Automatic
Ball Bonder Shared Collection Events
The Collection Events (CEs) and associated Collection Event IDs (CEID) shared by K&S Model Power
Series Automatic Ball Bonder and K&S Model Gen-S Automatic Ball Bonder are described in this section.
Page - 170 - of 324
Jan 28, 2021 Rev 4.2
Kulicke & Soffa™
SECS/GEM Interface for K&S Ball Bonders
Bonder software version x-xx-x-473-series
IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Collection Events
CEID
Name
Description
8001
Control State Changed to
Online-Local
WB transitions to the Online-Local control state. See the "WB
communication/control state transition diagram". Recommend
that a RPTID containing the SV's "ControlState" and
"PreviousControlState" be linked to this event.
8002
Control State Changed to
Online-Remote
WB transitions to the Online-Remote control state. See the "WB
communication/control state transition diagram". Recommend
that a RPTID containing the SV's "ControlState" and
"PreviousControlState" be linked to this event.
8003
Control State Changed to
Offline
WB transitions to an Offline control state. See the "WB
communication/control state transition diagram". Recommend
that a RPTID containing the SV's "ControlState" and
"PreviousControlState" be linked to this event.
8004
Process State Change
WB transitions between any process state. Recommend that a
RPTID containing the SV's "ProcessState" and
"PreviousProcessState" be linked to this event.
8006
SpoolingDeactivated
WB has emptied spool and has no more messages to transmit.
8007
SpoolingActivated
WB has begun spooling due to a communications failure.
8008
SpoolingXmitFail
WB has detected a communication failure while transmitting
spooled data to the host. Unloading of spooled data has ceased.
8010
TerminalMsgAck
Operator has read and acknowledged a terminal message.
8011
Operator EC Change
Operator has modified an equipment constant. Recommend that
a RPTID containing the DVVAL
8012
New Output Magazine
Required
WB Output Side ready for new (empty) output mag
8013
Process Monitoring Data
Ready
Data generated in response to the host-initiated remote
command CALC_PM_DATA is ready.
8014
Process Program Change
Operator has modified a process program.
8015
CE_SAFETY_KIT_SNS_CH
ANGED
Safety kit sensor status changed
8016
CE_FOCUS_ADJ_CONFIG_
CHANGED
Whenever there is change in focus adjustment configuration
parameters.
8017
CE_PRIV_USER_DB_UPDA
TE_SUCCESS
Notify host password database update successfully
8018
CE_PRIV_USER_DB_UPDA
TE_FAIL
Notify host password database update fail
8020
Operation Mode Change
Equipment operation mode has changed. Recommend that a
RPTID containing a status variable "Equipment Mode" be linked
to this event.
8021
Light Tower Status Change
The light tower changed from one state to another. Recommend
that a RPTID containing a status variable "Light Tower State" be
linked to this event.
(U2)
Page - 171 - of 324
Jan 28, 2021 Rev 4.2
Kulicke & Soffa™
SECS/GEM Interface for K&S Ball Bonders
Bonder software version x-xx-x-473-series
IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Collection Events
CEID
Name
Description
8022
Operator Data Entry
This message is sent on command by the operator.
Recommend that a RPTID containing the status variable
"Operator Data A", "Operator Data B", and "Operator data ID" be
linked to this event.
8023
CE_Clear_FA_Data
Clear all data in an operator data dialog
8024
CE_Auto_Inhibited
Auto is inhibited by host
8025
PBI-NOSTOP-ERR
PBI:PBI No stop error
8028
CE_OPE_Mode_Change
OPE mode or an activity in an OPE mode has changed.
(U2)
Note: This event is generated when an item in the main OPE
dialog is selected, an intermediate sub-mode is displayed or
when an ite in the lowest level sub-mode is selected.
8029
CE_Process_Start
The equipment has started or resued execution of process
program
8030
CE_Process_Stop
Process program execution has ended. Equipment is no longer
in Auto mode.
8031
AUTO-CHANGED-TOOL
The equipment tool has been changed.
8032
CE_Process_Assist
Process program execution has stopped due to
alarms/execptions. At this point the equipment is still Auto mode
waiting for the user to clear the alarms.
Note:OPE host may use this event as the Outpu Stop signal from
the equipment.
8033
CE_OPE_Tech_ID_Change
The OPE Tech ID has been changed. This event is generated
every time the OPE Tech ID dialog is closed.
8034
MHS_CARRIER_EJECTED
This event is generated every time a leadframe is ejected into the
output magazine.
8035
CE_Process_Pause
This event is generated when the Run/Stop button is pressed
during Auto Run mode to pause (Sequence Stop) process
program execution.
Note:OPE host may use this event as the Output Stop signal
from the equipment.
8036
CE_RcmdStart_Aborted
Remote command PROCESS_START has been aborted.
8037
UPDATE_ERROR_GROUP
S
Error group has been updated.
8038
UPDATE_MACHINE_STAT
ES
Machine state has been updated.
8039
Auto BITS Status Changed
The global BITS state has been changed. The BITS state is
manually changed in the Auto Run Configuration or BITS
Configuration dialog.
8040
Changed Wire Spool
Operator has changed the Wire Spool length. The event is
triggered when the Change Wire Spool item of Wire Usage
dialog is selected.
Page - 172 - of 324
Jan 28, 2021 Rev 4.2
Kulicke & Soffa™
SECS/GEM Interface for K&S Ball Bonders
Bonder software version x-xx-x-473-series
IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Collection Events
CEID
Name
Description
8041
CAL_USG_SUCCESSFUL
USG calibration was performed. The event is triggered when the
Accept item is selected from the USG Tune Results dialog.
8042
ASSIST_COMPLETE
When the alarm type is configured to be ON/OFF, operator's
selection from the main event handler dialog has been
completed, i.e. continue, retry, abort, recover, or done.
(U2)
When the alarm type is configured to be “ASK”, the operator has
selected a reason code.
8043
PBI_UNIT_INSPECT_COM
PLETED
PBI: Inspection of a unit has completed
8044
PBI_CONFIG_CHANGED
PBI: Config has been changed.
8045
PBI_STATISTICS_RESET
PBI: Statistics has been reset.
8046
CE_POWERSAVE_CONFIG
_CHANGED
Whenever there is change in a power save configuration
parameters
8048
O_MAG_EJECT_THRESHO
LD_WARNING_HEADER
Output magazine eject threshold has been reached.
8049
CE_WireCtrl_Config_Chang
ed
The start/stop wire control parameters has been changed.
8050
CE_PROCESS_MON_DAT
A_UPDATED
PM status variable data 3500-3520 has been updated.
8051
CE_INCORRENT_PM_DAT
A
The PM data is incorrent
8052
CE_CM_LOG_READY
Customized Log File is ready
8053
CE_CM_LOG_FAIL
Fail to generate customized Log File
8054
CE_PART_MAP_DLOAD_A
BORT
Abort the part map download process
8060
EH_AUTO_SHTL_RECV_A
TTEMPTED
Triggered while Short tail recovery attempts
8061
EH_AUTO_SHTL_RECV_S
UCCESS
Triggered while Short tail recovery attempts success
8062
EH_AUTO_EFO_OPEN_RE
CV_ATTEMPTED
Triggered while EFO open recovery attempts
8063
EH_AUTO_EFO_OPEN_RE
CV_SUCCESS
Triggered while EFO open recovery success
8064
EH_VACUUM_ERROR_SKI
PPED_REPORT
CEID triggered when skip package for vacuum error
8065
CE_START_INDEX_DEVIC
E
CEID triggered when start index device to bondsite
8066
CE_OPE_STATE_CHANGE
D
OPE State Changed
8067
CE_Start_Process_Device
CEID triggered when start to process device
Page - 173 - of 324
Jan 28, 2021 Rev 4.2
Kulicke & Soffa™
SECS/GEM Interface for K&S Ball Bonders
Bonder software version x-xx-x-473-series
IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Collection Events
CEID
Name
Description
8070
EH_AUTO_LHM_MEASURE
_COMPLETED
LHM: Measurement has completed
8080
CE_SUBSYSTEM_CONFIG
_CHANGED
Notify host when subsystem configuration changed.
8085
CE_Xhair_Offset_Limit_Set_
Chg
Message for xhair offset limit setting changed
8086
CE_Xhair_Offset_Out_Limit
Message for xhair offset is out of limit
8090
CE_UserDefinedSV_Change
d
UserDefinedSV Changed
8091
CE_User_Defined_CE1
A Customer-defined event to indicate the start of a lot.
8092
CE_User_Defined_CE2
A Customer-defined event to indicate the end of a lot.
8093
CE_User_Defined_CE3
A Customer-defined event to indicate the cancellation of a lot.
8094
CE_User_Defined_CE4
User Defined Event and event description
8100
PP Download
Equipment has completed downloading the process program,
whether successful or not. Recommend that a RPTID containing
the SV’s "DownloadPPName" and "DownloadPPStatus" be
linked to this event.
8101
PP Upload
Equipment has completed preparing the process program for
upload subsequent to receipt of a PP_PREP remote command.
Recommend that a RPTID containing the SV’s "UploadPPName"
and "UploadPPStatus" be linked to this event.
8102
HIT Transition
Operator has entered or left HIT Mode. Recommend that a
RPTID containing the SV’s "HitMode" be linked to this event.
8103
PP Select OK
The equipment has successfully loaded the Process Program
requested in the host-initiated remote command PP_SELECT.
8104
PP Select Failed
The equipment has detected an error while loading the Process
Program requested in the host-initiated remote command
PP_SELECT.
8105
PP Modified
Indicates the process program has been modified. Recommend
that a RPTID containing the SV "PPEditDialog" be linked to this
event.
8106
Process Program Clear
Process program in RAM has been cleared.
8107
Bond Parameter Changed
Process program bond parameter has been changed.
8108
Bond Location Changed
Process program bond location has been changed.
8109
PARM_LIMITS_EDITED
Default bond parameter limit has been changed
8110
ENTERING_PP_CONV
Process Program conversion sequence started
8111
PP_CONV_COMPLETE
Process Program conversion sequence completed
8112
PP_CONV_ABORTED
Process Program conversion sequence aborted
8113
CE_LTO_OVERRIDE_ON
LightTowerOverride ENABLED
(U2)
Page - 174 - of 324
Jan 28, 2021 Rev 4.2
Kulicke & Soffa™
SECS/GEM Interface for K&S Ball Bonders
Bonder software version x-xx-x-473-series
IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Collection Events
CEID
Name
Description
8114
CE_LTO_OVERRIDE_OFF
LightTowerOverride DISABLED
8115
CE_Bond_Limit_Edited
It is triggered while bond limit has been edited.
8116
CE_Hour_Limit_Edited
It is triggered while hour limit has been edited.
8117
CE_PrivLevel_Changed
It is triggered while privilege level changed.
8118
CE_UPDATE_BOND_PARA
M_SV
Send out once Bond Parameter related SVIDs updated
8119
CE_INDEX_PROHIBIT_BY_
RAIL_HEIGHT
Event to notify host that indexing is prohibited due to
unacceptable rail height
8120
CE_AUTO_MINOR_CONV_
COMPLETE
CEID for auto minor conversion completion
8130
Misc_PP_Edit
Occurs when one of the following process program edits is
performed:
(U2)
- Delete bond site
- Resequence wires
- Delete wire
- Add wire
- Regroup wire
- Delete reference system
- Move reference system
- Rotate reference system
- Copy reference system
- Copy device
- Move device
- Delete device
- Resequence device
- Rotate device
Recommend that a RPTID containing the status variable
"Completed PP Edit" (SVID 3116) be linked to this event.
Notes:
1. Reserved for KNET use only.
2. Disabled is the default setting.
8131
CE_Mag_Eject_Opt_Change
d
Eject magazine option has been changed
Page - 175 - of 324
Jan 28, 2021 Rev 4.2
Kulicke & Soffa™
SECS/GEM Interface for K&S Ball Bonders
Bonder software version x-xx-x-473-series
IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Collection Events
CEID
Name
Description
8132
CE_PP_SAVE_RENAME_D
ELETE
PP has been SAVE/RENAME/DELETE. Recommend that a
RPTID containing the status variable SV_PP_ID (SVID 3117)
and PP_SAVE_RENAME_DELETE_STAT (SVID 3118) be
linked to this event.
8133
EH_AUTO_FALSE_NSOP_
DETECTED
This Event will be sent when backup PRS NSOP auto recovery
successfully.
8134
CE_BITSSTATE_BACKUP_
PRS_NSOP_CHANGED
BITS State Backup PRS NSOP Changed.
8135
CE_USG_PERSONALITY_V
ALUE_CHANGED
Change any of the values on “Personality Values"
8136
CE_USG_PERIODIC_SCAN
USG PERIODIC SCAN
8139
CE_MULTI_STAGE_BOND_
CHANGED
Notify host when cap break in parameter changed.
8140
CE_MDP_CHANGED
This event will be trigger when Personality Current Factor
Changed
8141
CE_MC_GUI_CAL_CONFIG
_CHANGED
Machine configured data which related to calibration is changed
8142
CE_ARV_STATE_CHG
ARV state is changed from GUI
8150
CE_IMH_RFID_POS_REAC
HED
Input Mag handler reach RFID position
8151
CE_OMH_RFID_POS_REA
CHED
Output Mag handler reach RFID position
8152
CE_OMH_RFID_POS_EJE
CT_REACHED
Output Mag handler reach eject position
8153
CE_IMH_LOAD_TO_ID_PO
S_MANUALLY
Load input magazine to ID Scan Position by clicking button “Load
New Mag to ID Scan Position”
8154
CE_OMH_LOAD_TO_ID_P
OS_MANUALLY
Load output magazine to ID Scan Position by clicking button
“Load New Mag to ID Scan Position”
8155
EH_INPUT_MAG_EJECT_H
OST_VALIDATION
Before input mag eject, send event to host to do verification, host
will decide whether it is possible to eject
8156
EH_OUTPUT_MAG_EJECT
_HOST_VALIDATION
Before output mag eject, send event to host to do verification,
host will decide whether it is possible to eject
8160
CE_ENTER_SAFETY_MOD
E
Operator request open door, machine enter safety mode
8161
CE_EXIT_SAFETY_MODE
Operator request close door, machine enter normal mode
8162
CE_OVERDRIVE_ENABLE
D
Operator turn on Overdrive key, machine enter safety mode, but
is allowed to perform operation
8163
CE_OVERDRIVE_DISABLE
D
Operator turn off Overdrive key, machine enter normal mode
(U2)
Page - 176 - of 324
Jan 28, 2021 Rev 4.2
Kulicke & Soffa™
SECS/GEM Interface for K&S Ball Bonders
Bonder software version x-xx-x-473-series
IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Collection Events
CEID
Name
Description
8164
CE_BYPASS_SAFETY_EN
ABLED
Operator turn on bypass mode, machine will be able to perform
operation in safety mode
8165
CE_BYPASS_SAFETY_DIS
ABLED
Operator turn off bypass mode, machine will not have exception
in safety mode
8200
Temperature_Zone1_Limit_
Event
The monitored temperature at pre bond has become either too
hot or too cool according to host-defined limits. Recommend that
a RPTID containing the DVVAL’s "LimitVariable",
"TransitionType" and "EventLimit" be linked to this event.
8201
Temperature Zone 2
Limit_Event
The monitored temperature at bond has become either too hot or
too cool according to host-defined limits. Recommend that a
RPTID containing the DVVAL’s "LimitVariable", "TransitionType"
and "EventLimit" be linked to this event.
8202
Temperature_Zone3_Limit_
Event
The monitored temperature at post bond has become either too
hot or too cool according to host-defined limits. Recommend that
a RPTID containing the DVVAL’s "LimitVariable",
"TransitionType" and "EventLimit" be linked to this event.
8203
CE_TEMP_ON_OFF_CHAN
GED
Temp Zone ON/OFF
8204
CE_TEMP_SETPOINT_CH
ANGED
Temp Setpoint
8205
CE_TEMP_OFFSET_CHAN
GED
Temp Offset
8206
CE_TEMP_TOL_CHANGED
Temp Tolerance
8210
CE_LP_Init_State_Report
Initial state of loadport after machine bootup.
8211
CE_LP_Transfer_ReadyToL
oad_To_Blocked
Port transfer state changes from ready to load to transfer blocked
8212
CE_LP_Transfer_Blocked_T
o_ReadyToLoad
Port transfer state changes from transfer blocked to ready to load
8213
CE_LP_Transfer_Blocked_T
o_ReadyToUnload
Port transfer state changes from transfer blocked to ready to
unload
8214
CE_LP_Transfer_ReadyToU
nload_To_ReadyToLoad
Port transfer state changes from ready to unload to ready to load
8215
CE_CarrierID_NotRead_To_
VerifyOK
Carrier ID status changes from not read to verify OK
8216
CE_CarrierID_NotRead_To_
WaitForHost
Carrier ID status changes from not read to wait for host
8217
CE_CarrierID_WaitForHost_
To_VerifyOK
Carrier ID status changes from wait for host to verify ok
8218
CE_CarrierID_WaitForHost_
To_VerifyFail
Carrier ID status changes from wait for host to verify fail
(U2)
Page - 177 - of 324
Jan 28, 2021 Rev 4.2
Kulicke & Soffa™
SECS/GEM Interface for K&S Ball Bonders
Bonder software version x-xx-x-473-series
IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Collection Events
CEID
Name
Description
8219
CE_CarrierAccess_NotAcce
ssed_To_InAccess
Carrier Accessing status changes from not accessed to in access
8220
CE_CarrierAccess_InAccess
_To_Complete
Carrier Accessing status changes from in access to carrier
complete
8221
CE_CarrierAccess_InAccess
_To_Stopped
Carrier Accessing status changes from in access to carrier
stopped
8222
CE_Carrier_SlotMap_NotRe
ad_To_VerifyOK
Carrier Slot Map status changes from not read to verify ok
8223
CE_Carrier_SlotMap_NotRe
ad_To_WaitForHost
Carrier Slot Map status changes from not read to wait for host
8224
CE_Carrier_SlotMap_WaitF
orHost_To_VerifyOK
Carrier Slot Map status changes from wait for host to verify ok
8225
CE_Carrier_SlotMap_WaitF
orHost_To_VerifyFail
Carrier Slot Map status changes from wait for host to verify fail
8226
CE_OHT_Enabled
OHT changes from disabled to enabled
8227
CE_OHT_Disabled
OHT changes from enabled to disabled
8228
CE_LP_Reservation_NotRe
served_To_Reserved
Load Port reservation state from not reserved to reserved
8229
CE_LP_Reservation_Reserv
ed_To_NotReserved
Load Port reservation state from reserved to not reserved
8230
CE_LP_Association_NotAss
ociated_To_Associated
Load Port association state changes from not associated to
associated
8231
CE_LP_Association_Associa
ted_To_NotAssociated
Load Port association state changes from associated to not
associated
8232
CE_Carrier_Location_Chang
e
Carrier location changes
8233
CE_Carrier_Created
Carrier Created
8234
CE_LP_Occupied
Load Port is occupied
8235
CE_LP_Empty
Load Port is empty
8236
CE_PJ_Queued
Process Job is queued
8237
CE_PJ_Queued_To_Setting
Up
Process Job from queued to setting up
8238
CE_PJ_SettingUp_To_Proc
essing
Process Job from setting up to processing
8239
CE_PJ_Processing_To_Co
mplete
Process Job from processing to complete
8240
CE_PJ_Executing_To_Pausi
ng
Process Job from executing to pausing
(U2)
Page - 178 - of 324
Jan 28, 2021 Rev 4.2
Kulicke & Soffa™
SECS/GEM Interface for K&S Ball Bonders
Bonder software version x-xx-x-473-series
IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Collection Events
CEID
Name
Description
8241
CE_PJ_Pausing_To_Pause
d
Process Job from pausing to paused
8242
CE_PJ_Paused_To_Executi
ng
Process Job from paused to executing
8243
CE_CJ_Queued
Control Job is queued
8244
CE_CJ_Queued_To_Selecte
d
Control Job from queued to selected
8245
CE_CJ_Selected_To_Execu
ting
Control Job from selected to executing
8246
CE_CJ_Executing_To_Paus
ed
Control Job from executing to paused
8247
CE_CJ_Paused_To_Executi
ng
Control Job from paused to executing
8248
CE_CJ_Executing_To_Com
pleted
Control Job from executing to completed
8249
CE_Substrate_Process_Star
t
Substrate starts to be processed
8250
CE_CarrierID_NotRead
Carrier ID status is not read
8251
CE_Carrier_SlotMap_NotRe
ad
Carrier Slot Map status is not read
8252
CE_CarrierAccess_NotAcce
ssed
Carrier accessing status is not accessed
8253
CE_AccessMode_Manual_T
o_Auto
Access mode changes from manual to auto
8254
CE_AccessMode_Auto_To_
Manual
Access mode changes from auto to manual
8255
MHS_CARRIER_PULLED_I
N
Substrate is registered at X sensor(at prebond)
8256
CE_CJ_Completed_To_NoS
tate
Control Job is destroyed after the last output carrier is processed
and removed from unload tray
8257
CE_PJ_PostActive_To_Extin
ction
Process Job is destroyed after its processed output carrier is
removed from the unload tray
8258
CE_PJ_QUEUED_To_NoSt
ate
Process Job is removed from the Queue
8259
CE_Carrier_To_NoState
Carrier is removed from unload tray and carrier object is
destroyed
8260
CE_CJ_QUEUED_To_NoSt
ate
Control job is removed from the queue
8267
CE_PP_Loaded_Only_With_
Process_Parameter
Apply the process parameter from pp in disk to pp in ram
successfully
(U2)
Page - 179 - of 324
Jan 28, 2021 Rev 4.2
Kulicke & Soffa™
SECS/GEM Interface for K&S Ball Bonders
Bonder software version x-xx-x-473-series
IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Collection Events
CEID
Name
Description
8268
CE_PP_LastSavedTime_Re
ady
The last saved timer retrieved from current process program is
ready
8300
MHS_MAG_IN_READY
Input side magazine is at index position.
8301
MHS_MAG_OUT_READY
Output side magazine is at index position.
8302
MHS_MAG_IN_UNLOAD
Input side MHS deposits a magazine on the unload tray for
pickup by the robot.
8303
MHS_MAG_OUT_UNLOAD
Output side MHS deposits a magazine on the unload tray for
pickup by the robot.
8304
Package Threshold Reached
Device Processed since last CEID8304 triggered reached the
configured Threshold by Equipment Constant (ECID1300)
8305
MHS_MAG_IN_BCR_SCAN
Input side MHS has scanned bar code of fresh magazine picked
up by the equipment. (Backload SMEMA only) This event is
predecessor to the EQC initiated remote command
"ACCEPT_IN_MAG" or "REJECT_IN_MAG" (S2 F41) which tells
the equipment whether it should process or unload the
magazine.
8306
MHS_MAG_OUT_BCR_SC
AN
Output side MHS has scanned bar code of fresh magazine
picked up by the equipment. (Backload SMEMA only) This event
is predecessor to the EQC initiated remote command
"ACCEPT_OUT_MAG" or "REJECT_OUT_MAG" (S2 F41) which
tells the equipment whether it should process or unload the
magazine.
8307
MHS_MAG_IN_MAG_REQU
EST
New input magazine required. This event is issued by the
equipment concurrent with the SMEMA "ready" signal on the
load tray of the input side.
8308
MHS_MAG_OUT_MAG_RE
QUEST
New output magazine required. This event is issued by the
equipment concurrent with the SMEMA "ready" signal on the
load tray of the output side.
8309
MHS_MAG_IN_BCR_REJE
CT
Material ID error at input side. Bar code scan failure on the input
side.
8310
MHS_MAG_OUT_BCR_REJ
ECT
Material ID error at output side. Bar code scan failure on the
output side.
8311
CE_IN_LOAD_PORT_STAT
E_CHG
Equipment preprocessing load port state has changed.
Recommend that a RPTID containing a status variable
"InLoadPortState" be linked to this event. Backload MMM only).
8312
CE_IN_UNLOAD_PORT_ST
ATE_CHG
Equipment preprocessing unload port state has changed.
Recommend that a RPTID containing a status variable
"InUnLoadPortState" be linked to this event. (Backload MMM
only).
8313
CE_OUT_LOAD_PORT_ST
ATE_CHG
Equipment postprocessing load port state has changed.
Recommend that a RPTID containing a status variable
"OutLoadPortState" be linked to this event. (Backload MMM
only).
(U2)
Page - 180 - of 324
Jan 28, 2021 Rev 4.2
Kulicke & Soffa™
SECS/GEM Interface for K&S Ball Bonders
Bonder software version x-xx-x-473-series
IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Collection Events
CEID
Name
Description
8314
CE_OUT_UNLOAD_PORT_
STATE_
CHG
Equipment postprocessing unload port state has changed.
Recommend that a RPTID containing a status variable
"OutUnLoadPortState" be linked to this event. event. (Backload
MMM only).
8315
Nearing Tool Usage Limit
Tool usage is approaching the limit.
8316
NUMERIC_LIMIT_OPTION_
CHANGED
This event is triggered when operator changes the Numeric Limit
Action from the Privileged Operations Menu.
8317
CE_IDLE_MODE_AUTO_CL
AMP_OPEN
Idle Mode Auto Clamp Open
8318
CE_REGRIPLEADFRAME_
CHANGED
Regrip Leadframe setting changed
8319
CE_REHOMEZ_CHANGED
Rehome Z magazine changed
8320
CE_COMM_DISABLED
Event that is generated when the operator disables
communications using the GUI.
(U2)
Generated before breaking communications.
8321
CE_Input_Magazine_Loade
d
Signal this event when Input Magazine Loaded.
8322
CE_Output_Magazine_Load
ed
Signal this event when Output Magazine Loaded.
8323
CE_Strip_From_Input_Maga
zine
Signal this event when a strip pulled from the input magazine to
the process area and ready for bonding.
8324
CE_Bond_Area_Process_St
art
Signal this event when the process of a bond area started. This
implies ready to bond the first device for each strip.
8325
CE_Device_PRS_Start
Signal this event when the initial / first PRS scan is done on each
device.
8326
CE_Device_Process_Start
Signal this event when bonding begins on each device.
8327
CE_Device_Process_Compl
ete
Signal this event when the last bond is completed on each
device.
8328
CE_Bond_Area_Process_C
omplete
Signal this event when the process of a bond area completed.
This implies the entire strip is processed and ready for ejection.
8329
CE_Strip_To_Output_Magaz
ine
Signal this event when a strip was moved to the output
magazine.
8330
CE_Input_Magazine_Auto_
Unload
Signal this event when Input Magazine Unloaded.
8331
CE_Output_Magazine_Auto
_Unload
Signal this event when Output Magazine Unloaded.
8332
AUTO_CONFIGURATION_
CHANGED
Auto configuration changed.
8333
RUN_CONFIGURATION_C
HANGED
Run configuration changed.
Page - 181 - of 324
Jan 28, 2021 Rev 4.2
Kulicke & Soffa™
SECS/GEM Interface for K&S Ball Bonders
Bonder software version x-xx-x-473-series
IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Collection Events
CEID
Name
Description
8334
CE_ErrCategory_Changed
Error category changed.
8335
CE_2D_Dot_Code_Scan
Vision 2D Code Reader Scan once Scan completed
8336
CE_Upload_Strip_Map
Strip bonding completed and ready to upload Strip Map Data
8337
CE_StripMap_State_Change
d
It is triggered while turning on or off strip map feature.
8338
OHT_IP_EMPTY_MAG_TR
ANSFER_REQ
Input mag ready for transfer(OHT only)
8339
OHT_OP_EMPTY_MAG_TR
ANSFER_REQ
Output mag ready for transfer(OHT only)
8340
CE_Input_Magazine_Ungrip
ped
Release input mag on unload tray
8341
CE_Output_Magazine_Ungri
pped
Release output mag on unload tray
8342
MHS_MAG_IN_MANUAL_U
NLOAD
Send CEID 8342 CE_Input_Magazine_Manual_Unloaded to host
when manual eject input magazine.
8343
MHS_MAG_OUT_MANUAL
_UNLOAD
Send CEID 8343 CE_Output_Magazine_Manual_Unloaded to
host when manual eject output magazine.
8344
CE_Input_Magazine_Unload
ed
Unload input mag complete
8345
CE_Output_Magazine_Unlo
aded
Unload output mag complete
8346
CE_ECO_CLAMP_OPEN
CEID for ECO Clamp Open
8347
CE_ECO_CLAMP_CLOSE
CEID for ECO Clamp Close
8348
CE_ECO_IDLE_MODE_EJE
CT_CARRIER
Start ejecting carrier in idle mode ECO
8349
CE_ECO_AUTO_MODE_EJ
ECT_CARRIER
Start ejecting carrier in auto mode ECO
8350
CE_GLOBAL_ID_VALIDATI
ON_SWITCH_CHANGED
Global ID validation switch changed.
8351
CE_DUMMY_STATE_CHAN
GED
Dummy State Changed
8352
CE_Upload_Substrate_Map
Strip bonding is complete and ready to upload xml map data
8354
CE_COMPRESS_FILE_FIN
Notify compress file or folder operation complete.
8355
CE_CLAMP_CLOSE_AFTE
R_ECO_OPEN
Clamp Close
8356
CE_STRIP_PASS_THROU
GH
A strip marked as pass through by host leaves WHL
8360
CE_WIRE_SPOOL_SEQ_S
TART
Wire Spool Sequence Start
(U2)
Page - 182 - of 324
Jan 28, 2021 Rev 4.2
Kulicke & Soffa™
SECS/GEM Interface for K&S Ball Bonders
Bonder software version x-xx-x-473-series
IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Collection Events
CEID
Name
Description
8361
CE_WIRE_SPOOL_SEQ_E
ND
Wire Spool Sequence End
8362
CE_WIRE_SPOOL_SEQ_VI
OLATION
Wire Spool Sequence Violation
8363
CE_WIRE_SPOOL_SEQ_F
AILURE
Wire Spool Sequence Failure
8364
CE_WIRE_SPOOL_COVER
_OPENED
Wire Spool Cover Opened
8365
CE_WIRE_SPOOL_COVER
_CLOSEED
Wire Spool Cover Closed
8366
CE_WIRE_SPOOL_INSTAL
LED
Wire Spool Installed
8367
CE_WIRE_SPOOL_REMOV
ED
Wire Spool Removed
8368
CE_WIRE_SPOOL_REMOV
AL_SEQ_DONE
Wire Spool Removal Sequence Done
8369
CE_WIRE_SPOOL_INSTAL
LMENT_SEQ_DONE
Wire Spool Installment Sequence Done
8370
CE_SINGLE_INTERACTIVE
_TM_OVERRIDDEN
Single interactive terminal message is overridden
8371
CE_SINGLE_INTERACTIVE
_TM_DESTROYED
Single interactive terminal message is destroyed
8372
CE_REQ_PP_FROM_HOST
Request PP list from host
8373
CE_SERIAL_PORT_ID_IN
ID info is grasped at serial port
8375
CE_Alarm_Assist
Operator start assist of error
8376
CE_AUTO_PAUSED_FOR_I
NJECT
Machine wait for new parts to input conveyor to start bonding
8377
CE_PAUSED_FOR_EJECT
Machine cannot eject out parts from output conveyor
8378
CE_CHANGEOVER_START
_WT_HOST
Changeover start request
8379
CE_AUTO_PAUSED_FOR_I
NJECT_RECOVERED
Recovery from pause for inject
8380
CE_PAUSED_FOR_EJECT
_RECOVERED
Recovery from pause for eject
8381
CE_CHANGEOVER_COMP
LETE
Changeover complete successfully
8382
CE_TOOLCHANGE_START
_WT_HOST
Tool change start request
8383
CE_WIRECHANGE_START
_WT_HOST
Wire change start request
(U2)
Page - 183 - of 324
Jan 28, 2021 Rev 4.2
Kulicke & Soffa™
SECS/GEM Interface for K&S Ball Bonders
Bonder software version x-xx-x-473-series
IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Collection Events
CEID
Name
Description
8384
CE_TOOLCHANGE_COMP
LETE
Tool change complete
8385
CE_WIRECHANGE_COMP
LETE
Wire change complete
8386
CE_PACKAGE_PROCESS_
START
Start process a package
8387
CE_CHANGEOVER_ABOR
T
Abort from changeover sequence
8388
CE_SUBTRATE_PROCESS
_COMPLETE
Complete process a substrate
8389
CE_AUTO_TOOL_USAGE_
LIMIT_REACHED
Tool usage limit reached (No EH Prompt)
8390
WHL_Center_LeadRef_1stL
eadBond_BH_Set
When SVID 3650
SV_PM_WHL_Center_LeadRef_1stLeadBond_BH has been set,
this CEID will be sent to host
8391
CE_ACC_MC_READY_LOA
D_CAP_CHANGER
Machine is ready for OHT to dock ACC
8392
CE_ACC_DOCK_SUCCESS
_SEQUENCE_START
ACC change cap sequence starting
8393
CE_ACC_SEQUENCE_CO
MPLETED
ACC change cap sequence complete
8394
CE_ACC_MC_READY_UNL
OAD_CAP_CHANGER
Machine is ready for OHT to undock ACC
8395
CE_ACC_UNDOCK_AND_U
NLOADED
ACC unload completed by OHT
8400
Data Set Download Done
Equipment has completed or terminated downloading data set
using Stream 13 messages. Recommend that a RPTID
containing the status variable FileXfrStat (SVID 3048) be linked
to this event.
8402
ML_Load_Port_Status_Chan
ged
Input Mag Handler load tray’s outer sensor status changed.
8403
ML_Unload_Port_Status_Ch
anged
Input Mag Handler load tray’s outer sensor status changed.
8404
MR_Load_Port_Status_Cha
nged
Output Mag Handler load tray’s outer sensor status changed.
8405
MR_Unload_Port_Status_Ch
anged
Output Mag Handler load tray’s outer sensor status changed.
8406
AGV_Control_Status_Chang
ed
AGV control status changed.
8407
AGV_VALID_Status_Chang
ed
AGV valid status changed.
(U2)
Page - 184 - of 324
Jan 28, 2021 Rev 4.2
Kulicke & Soffa™
SECS/GEM Interface for K&S Ball Bonders
Bonder software version x-xx-x-473-series
IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Collection Events
CEID
Name
Description
8408
EJECT_INPUT_MAGAZINE
_NOT_EMPTY
Ejected input magazine is not empty.
8409
ML_Load_Limit_Sns_Status
_Changed
Input Mag Handler load tray’s inner limit sensor status changed
8410
MR_Load_Limit_Sns_Status
_Changed
Ouput Mag Handler load tray’s inner limit sensor status changed
8411
OHT_Control_Status_Chang
ed
Overhead Host Transport status changed
8420
CE_Calibration_Successful
A successful calibration is done.
8421
CAL_XHAIR_MAP_SUCCE
SSFUL
Cal Xhair Map Successful
8422
EH_PERIODIC_EFO_HEIG
H_CHECK_PERFORM
Periodic EFO height calibration performs
8430
CE_CAP_CLEAN_START
Cap Clean Start
8431
CE_CAP_CLEAN_TAPE_C
HANGED
Cap Clean State Changed
8432
CAP_CLEANING_REACHIN
G_LIMIT
Cap Clean Reach Limit
8440
EDIT_DEVICE_STATUS_D
ONE
Edit Device Status completed.
8450
CE_LOT_START
Triggered when first input mag loaded and Lot becomes ACTIVE
8451
CE_LOT_END
Triggered when all L/Fs processed and Lot becomes END
8452
CE_LOT_SPEC_INIT
Triggered when WB accept the INIT_LOT_SPEC
8453
CE_LOT_ABORT
Triggered when WB completed the LOT under below conditions:
(U2)
1.The last input mag specified in lot specification is ejected.
2. No remaining lead freames are in processing in WHL.
3.The output magazine is ejected automatically or manually.
8454
CE_LOT_FIRST_LF_PULLE
D_IN
Lot First Lead Fream Pulled In
8460
Run_Stop_Pressed
Auto Run/Stop Button Pressed
8461
CE_MHS_CONV_DONE_AF
T_LOADING_PP
PP_Loaded MHS Coversion Done
8462
CE_Manual_Skip_Device
Manual Skip Device
8463
CE_AUTO_ERR_SKIP_UNI
T
Auto Error Skip Device:Notify host when configured auto error
triggered skip unit
8464
IND_NOT_BONDED_CARRI
ER_JAM
JAM error with not completely bonded LF
Page - 185 - of 324
Jan 28, 2021 Rev 4.2
Kulicke & Soffa™
SECS/GEM Interface for K&S Ball Bonders
Bonder software version x-xx-x-473-series
IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Collection Events
CEID
Name
Description
8470
CE_BONDSITE_CHKSUM_
MISMATCH
Bond Site Location checksum mismatch (Prevent for wrong
bond)
8471
CE_WRONG_BOND_CHEC
KSUM_ERROR_DETECT
Wrong Bond Checksum Error Detected
8472
CE_Alarm_Set
General Alarm Set Event.Report should contain DVID
10009/DVID10010 when link this event.
8473
CE_Device_Alarm_Detect
CEID triggered when an alarm detect
8480
CE_CARRIER_EJECTED_C
OMPLETE
Carrier Ejected to Mag Completed
8481
CE_OHT_Insp_Mode_Statu
s_Changed
Insp mode status changed
8482
CE_OHT_INSP_PENDING_
TO_READY
Insp pending to ready
8483
CE_OHT_Insp_Ready
MC ready to inspect
8484
CE_OHT_Insp_Confirm
Inspection confirmed
8485
CE_OHT_Insp_Retry
Inspection need retry
8486
CE_OHT_MC_START_RUN
User press Run/Stop, Mc try to Run
8487
CE_OHT_INPUT_LOAD_RE
QUEST
Input load tray empty
8488
CE_OHT_OUTPUT_LOAD_
REQUEST
Output load tray empty
8489
CE_MHS_MAG_GRIPPED
Input Mag Gripped by input mag handler
8490
CE_MHS_MAG_GRIPPED_
O
Output Mag Gripped by output mag handler
8491
ML_Load_Port_Occupied
Input load tray sensor blocked
8492
MR_Load_Port_Occupied
output load tray sensor blocked
8493
ML_Load_Port_MANUAL_E
mpty
Input load tray sensor unblocked due to magazine removed
8494
MR_Load_Port_MANUAL_E
mpty
output load tray sensor unblocked due to magazine removed
8495
ML_Load_Limit_Port_Manau
l_Empty
Input load tray limit sensor unblocked due to magazine removed
8496
MR_Load_Limit_Port_Mana
ul_Empty
output load tray limit sensor unblocked due to magazine removed
8497
ML_Unload_Port_Manual_E
mpty
Operator pick input magazine before it reach tray sensor position
8498
MR_Unload_Port_Manual_E
mpty
Operator pick output magazine before it reach tray sensor
position
(U2)
Page - 186 - of 324
Jan 28, 2021 Rev 4.2
Kulicke & Soffa™
SECS/GEM Interface for K&S Ball Bonders
Bonder software version x-xx-x-473-series
IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Collection Events
CEID
Name
Description
8499
CE_IMH_ID_PRE_REQUES
T
Pre-request mag id for input magazine
8500
CE_OMH_ID_PRE_REQUE
ST
Pre-request mag id for output magazine
8501
MHS_IMH_ID_PRE_SCAN_
COMPLETED
Pre-scan mag id for input magazine sucessfully
8502
MHS_OMH_ID_PRE_SCAN
_COMPLETED
Pre-scan mag id for output magazine sucessfully
8503
CE_OUT_REPORT_EVENT
Trigger after all carriers processed and transferred into the
magazine in unloader port
8504
CE_IMH_Start_Auto_Ungrip
ped
Trigger when input magazine handler start to ungrip input
magazine
8505
CE_OMH_Start_Auto_Ungri
pped
Trigger when output magazine handler start to ungrip output
magazine
8506
CE_IMH_Start_Manual_Ung
ripped
Trigger when input magazine handler start to ungrip input
magazine
8507
CE_OMH_Start_Manual_Un
gripped
Trigger when output magazine handler start to ungrip output
magazine
8508
CE_Alarm_Report
EH dialog pop up
8509
CE_Alarm_Clear
EH dialog clear
8510
WIRE_INSP_UNIT_INSPEC
T_COMPLETED
Wire inspection of a unit has completed
8511
WIRE_INSP_CONFIG_CHA
NGED
Wire inspection config has been changed
8512
WIRE_INSP_STATISTICS_
RESET
Wire inspection statistics has been reset
8901
GEM_CTRL_STATE_CHAN
GED
The equipment has changed control state. Recommend that a
RPTID containing the SV’s "ControlState" and
"PreviousControlState" be linked to this event.
8902
CE_LogFile_Shuffled
Triggered while log file is full (1.3MB) and shuffled.
9010
PDT-EFO-OPEN-SET
Alarm set: PDT-EFO-OPEN
9011
PDT-EFO-OPEN-CLEAR
Alarm clear: PDT-EFO-OPEN
9012
PDT-EFO-OPEN-EXCLUDE
PDT EFO OPEN for MTBA.
9020
PDT-EFO-SHORT-SET
Alarm set: PDT-EFO-SHORT
9021
PDT-EFO-SHORT-CLEAR
Alarm clear: PDT-EFO-SHORT
9030
PDT-EFO-ERROR-SET
Alarm set: PDT-EFO-ERROR
9031
PDT-EFO-ERROR-CLEAR
Alarm clear: PDT-EFO-ERROR
9040
EFO-HAZARD-SET
Alarm set: EFO-HAZARD
(U2)
Page - 187 - of 324
Jan 28, 2021 Rev 4.2
Kulicke & Soffa™
SECS/GEM Interface for K&S Ball Bonders
Bonder software version x-xx-x-473-series
IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Collection Events
CEID
Name
Description
9041
EFO-HAZARD-CLEAR
Alarm clear: EFO-HAZARD
9050
PDT-WIREFEED-ERRORSET
Alarm set: PDT-WIREFEED-ERROR
9051
PDT-WIREFEED-ERRORCLEAR
Alarm clear: PDT-WIREFEED-ERROR
9060
MANUAL-EFO-OPEN-SET
Alarm set: MANUAL-EFO-OPEN
9061
MANUAL-EFO-OPENCLEAR
Alarm clear: MANUAL-EFO-OPEN
9070
MANUAL-EFO-SHORT-SET
Alarm set: MANUAL-EFO-SHORT
9071
MANUAL-EFO-SHORTCLEAR
Alarm clear: MANUAL-EFO-SHORT
9080
MANUAL-EFO-ERROR-SET
Alarm set: MANUAL-EFO-ERROR
9081
MANUAL-EFO-ERRORCLEAR
Alarm clear: MANUAL-EFO-ERROR
9090
MANUAL-EFO-HAZARDSET
Alarm set: MANUAL-EFO-HAZARD
9091
MANUAL-EFO-HAZARDCLEAR
Alarm clear: MANUAL-EFO-HAZARD
9100
AUTO-TEMP-OUT-OFLIMITS-SET
Alarm set: AUTO-TEMP-OUT-OF-LIMITS
9101
AUTO-TEMP-OUT-OFLIMITS-CLEAR
Alarm clear: AUTO-TEMP-OUT-OF-LIMITS
9110
FATAL-ERROR-SET
Alarm set: FATAL-ERROR
9111
FATAL-ERROR-CLEAR
Alarm clear: FATAL-ERROR
9120
OS-ERROR-SET
Alarm set: OS-ERROR
9121
OS-ERROR- CLEAR
Alarm clear: OS-ERROR
9130
INTERNAL-ERROR-SET
Alarm set: INTERNAL-ERROR
9131
INTERNAL-ERROR-CLEAR
Alarm clear: INTERNAL-ERROR
9140
PROCESS-ERROR-SET
Alarm set: PROCESS-ERROR
9141
PROCESS-ERROR-CLEAR
Alarm clear: PROCESS-ERROR
9150
MHS_MOTOR_DRIVER_ER
ROR-SET
Alarm set: MHS_MOTOR_DRIVER_ERROR
9151
MHS_MOTOR_DRIVER_ER
ROR-CLEAR
Alarm clear: MHS_MOTOR_DRIVER_ERROR
9160
IND_DEVICE_OVERHEATE
D-SET
Alarm set: IND_DEVICE_OVERHEATED
9161
IND_DEVICE_OVERHEATE
D-CLEAR
Alarm clear: IND_DEVICE_OVERHEATED
(U2)
Page - 188 - of 324
Jan 28, 2021 Rev 4.2
Kulicke & Soffa™
SECS/GEM Interface for K&S Ball Bonders
Bonder software version x-xx-x-473-series
IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Collection Events
CEID
Name
Description
9170
IND_NO_CLAMP_VACUUM
-SET
Alarm set: IND_NO_CLAMP_VACUUM
9171
IND_NO_CLAMP_VACUUM
-CLEAR
Alarm clear: IND_NO_CLAMP_VACUUM
9180
IND_CARRIER_JAM-SET
Alarm set: IND_CARRIER_JAM
9181
IND_CARRIER_JAMCLEAR
Alarm clear: IND_CARRIER_JAM
9190
MH_BAD_GRIPPER_CHAN
GE-SET
Alarm set: MH_BAD_GRIPPER_CHANGE
9191
MH_BAD_GRIPPER_CHAN
GE–CLEAR
Alarm clear: MH_BAD_GRIPPER_CHANGE
9220
MON-X-MOTOR-OVERTEMP–SET
Alarm set: MON-X-MOTOR-OVER-TEMP
9221
MON-X-MOTOR-OVERTEMP–CLEAR
Alarm clear: MON-X-MOTOR-OVER-TEMP
9230
MON-YL-MOTOR-OVERTEMP–SET
Alarm set: MON-YL-MOTOR-OVER-TEMP
9231
MON-YL-MOTOR-OVERTEMP–CLEAR
Alarm clear: MON-YL-MOTOR-OVER-TEMP
9240
MON-YR-MOTOR-OVERTEMP–SET
Alarm set: MON-YR-MOTOR-OVER-TEMP
9241
MON-YR-MOTOR-OVERTEMP–CLEAR
Alarm clear: MON-YR-MOTOR-OVER-TEMP
9250
MON-Z-MOTOR-OVERTEMP–SET
Alarm set: MON-Z-MOTOR-OVER-TEMP
9251
MON-Z-MOTOR-OVERTEMP–CLEAR
Alarm clear: MON-Z-MOTOR-OVER-TEMP
9260
MON-T-MOTOR-OVERTEMP–SET
Alarm set: MON-T-MOTOR-OVER-TEMP
9261
MON-T-MOTOR-OVERTEMP–CLEAR
Alarm clear: MON-T-MOTOR-OVER-TEMP
9270
MON-RACK-OVER-TEMP–
SET
Alarm set: MON-RACK-OVER-TEMP
9271
MON-RACK-OVER-TEMP–
CLEAR
Alarm clear: MON-RACK-OVER-TEMP
9280
MON-PSUPPLY-OVERTEMP–SET
Alarm set: MON-PSUPPLY-OVER-TEMP
9281
MON-PSUPPLY-OVERTEMP–CLEAR
Alarm clear: MON-PSUPPLY-OVER-TEMP
(U2)
Page - 189 - of 324
Jan 28, 2021 Rev 4.2
Kulicke & Soffa™
SECS/GEM Interface for K&S Ball Bonders
Bonder software version x-xx-x-473-series
IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Collection Events
CEID
Name
Description
9290
MON-WIREFEED-AIRDOWN–SET
Alarm set: MON-WIREFEED-AIR-DOWN
9291
MON-WIREFEED-AIRDOWN–CLEAR
Alarm clear: MON-WIREFEED-AIR-DOWN
9300
MON-SYSTEM-AIR-DOWN–
SET
Alarm set: MON-SYSTEM-AIR-DOWN
9301
MON-SYSTEM-AIR-DOWN–
CLEAR
Alarm clear: MON-SYSTEM-AIR-DOWN
9310
MON-STEP1-BD-FAULT–
SET
Alarm set: MON-STEP1-BD-FAULT
9311
MON-STEP1-BD-FAULT–
CLEAR
Alarm clear: MON-STEP1-BD-FAULT
9320
MON-STEP2-BD-FAULT–
SET
Alarm set: MON-STEP2-BD-FAULT
9321
MON-STEP2-BD-FAULT–
CLEAR
Alarm clear: MON-STEP2-BD-FAULT
9330
TEMP_ZONE_OPEN_LOOP
_ERROR–SET
Alarm set: TEMP_ZONE_OPEN_LOOP_ERROR
9331
TEMP_ZONE_OPEN_LOOP
_ERROR–CLEAR
Alarm clear: TEMP_ZONE_OPEN_LOOP_ERROR
9340
POWER-FAILURE–SET
Alarm set: POWER-FAILURE
9341
POWER-FAILURE–CLEAR
Alarm clear: POWER-FAILURE
9350
POWER-LOW–SET
Alarm set: POWER-LOW
9351
POWER-LOW–CLEAR
Alarm clear: POWER-LOW
9360
POWER-OVERTEMP–SET
Alarm set: POWER-OVERTEMP
9361
POWER-OVERTEMP–
CLEAR
Alarm clear: POWER-OVERTEMP
9370
SYSTEM-FAILURE–SET
Alarm set: SYSTEM-FAILURE
9371
SYSTEM-FAILURE–CLEAR
Alarm clear: SYSTEM-FAILURE
9380
PFAIL-DETECT–SET
Alarm set: PFAIL-DETECT
9381
PFAIL-DETECT–CLEAR
Alarm clear: PFAIL-DETECT
9390
PFAIL-SHUTDOWNINCOMPLETE–SET
Alarm set: PFAIL-SHUTDOWN-INCOMPLETE
9391
PFAIL-SHUTDOWNINCOMPLETE–CLEAR
Alarm clear: PFAIL-SHUTDOWN-INCOMPLETE
9400
PFAIL-SHUTDOWNUNUSABLE–SET
Alarm set: PFAIL-SHUTDOWN-UNUSABLE
(U2)
Page - 190 - of 324
Jan 28, 2021 Rev 4.2
Kulicke & Soffa™
SECS/GEM Interface for K&S Ball Bonders
Bonder software version x-xx-x-473-series
IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Collection Events
CEID
Name
Description
9401
PFAIL-SHUTDOWNUNUSABLE–CLEAR
Alarm clear: PFAIL-SHUTDOWN-UNUSABLE
9410
PFAIL-RECOVERYFAILURE–SET
Alarm set: PFAIL-RECOVERY-FAILURE
9411
PFAIL-RECOVERYFAILURE–CLEAR
Alarm clear: PFAIL-RECOVERY-FAILURE
9420
PFAIL-DIRTY-PROGRAM–
SET
Alarm set: PFAIL-DIRTY-PROGRAM
9421
PFAIL-DIRTY-PROGRAM–
CLEAR
Alarm clear: PFAIL-DIRTY-PROGRAM
9430
PFAIL-BONDOFF-FAILEDSET
Alarm set: PFAIL-BONDOFF-FAILED
9431
PFAIL-BONDOFF-FAILEDCLEAR
Alarm clear: PFAIL-BONDOFF-FAILED
9440
PFAIL-SHUTDOWNPROCESS-ERROR–SET
Alarm set: PFAIL-SHUTDOWN-PROCESS-ERROR
9441
PFAIL-SHUTDOWNPROCESS-ERROR–CLEAR
Alarm clear: PFAIL-SHUTDOWN-PROCESS-ERROR
9450
PFAIL-SHUTDOWN-FATALERROR–SET
Alarm set: PFAIL-SHUTDOWN-FATAL-ERROR
9451
PFAIL-SHUTDOWN-FATALERROR–CLEAR
Alarm clear: PFAIL-SHUTDOWN-FATAL-ERROR
9460
SERVO_FAULT–SET
Alarm set: SERVO_FAULT
9461
SERVO_FAULT–CLEAR
Alarm clear: SERVO_FAULT
9470
PARM_TYPE_INVALID-SET
Alarm set: PARM_TYPE_INVALID
9471
PARM_TYPE_INVALIDCLEAR
Alarm clear: PARM_TYPE_INVALID
9480
EH_FAINT6_FAULT-SET
Alarm Set: EH_FAINT6_FAULT
9481
EH_FAINT6_FAULT-CELAR
Alarm Clear: EH_FAINT6_FAULT
9490
PDT-UNEXPECTED-NSOPSET
Alarm Set: PDT Error - Unexpected BITS Error NSOP
9491
PDT-UNEXPECTED-NSOPCLEAR
Alarm Clear: PDT Error - Unexpected BITS Error NSOP
9492
PDT-UNEXPECTED-NSOPEXCLUDE
PDT NSOP for MTBA.
9500
PDT-UNEXPECTED NSOLSET
PDT Error - BITS Error NSOL
9501
PDT-UNEXPECTED-NSOLCLEAR
Alarm Clear: PDT Error - Unexpected BITS Error NSOL
(U2)
Page - 191 - of 324
Jan 28, 2021 Rev 4.2
Kulicke & Soffa™
SECS/GEM Interface for K&S Ball Bonders
Bonder software version x-xx-x-473-series
IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Collection Events
CEID
Name
Description
9502
PDT-UNEXPECTED-NSOLEXCLUDE
PDT NSOL for MTBA.
9510
PDT-UNEXPECTED-SHTLSET
Alarm Set: Unexpected PDT Error - BITS Error SHTL
9511
PDT-UNEXPECTED-SHTLCLEAR
Alarm Clear: PDT Error – Unexpected BITS Error CLEAR
9512
PDT-UNEXPECTED-SHTLEXCLUDE
PDT SHTL for MTBA.
9520
AUTO-ALIGN-FIND-FAILSET
Alarm Set: ALIGN status - inadequate eye points found
9521
AUTO-ALIGN-FIND-FAILCLEAR
Alarm Clear: ALIGN status - inadequate eye points found
9530
AUTO-ALIGN-LTOL-FAILSET
Alarm Set: ALIGN status - line distance outside tolerance
9531
AUTO-ALIGN-LTOL-FAILCLEAR
Alarm Clear: ALIGN status - line distance outside tolerance
9540
AUTO-VLL-FIND-FAIL-SET
Alarm Set: ALIGN status - line distance outside tolerance
9541
AUTO-VLL-FIND-FAILCLEAR
Alarm Clear: ALIGN status - line distance outside tolerance
9550
AUTO-VLL-WIDTH-FAILSET
Alarm Set: VLL Error - lead width out of tolerance
9551
AUTO-VLL-WIDTH-FAILCLEAR
Alarm Clear: VLL Error - lead width out of tolerance
9560
AUTO-XHAIR-ERROR-SET
Alarm Set: Auto X Hair Correction Error
9561
AUTO-XHAIR-ERRORCLEAR
Alarm Clear: Auto X Hair Correction Error
9570
AUTO-DRIFT-ERROR-SET
Alarm Set: X Hair Offset Inaccurate
9571
AUTO-DRIFT-ERRORCLEAR
Alarm Clear: X Hair Offset Inaccurate
9580
AUTO-TOOL-USAGE-LIMITEXCEEDED-SET
Alarm Set: Tool Usage Limit Exceeded
9581
AUTO-TOOL-USAGE-LIMITEXCEEDED-CLEAR
Alarm Clear: Tool Usage Limit Exceeded
9590
AUTO-BONDHEADSAFETY-VIOLATION-SET
Alarm Set: Bond Head Safety Violation
9591
AUTO-BONDHEADSAFETY-VIOLATIONCLEAR
Alarm Clear: Bond Head Safety Violation
9600
AUTO-BONDHEAD-TABLEVIOLATION-SET
Alarm Set: Bond Head Table Size Violation #254
(U2)
Page - 192 - of 324
Jan 28, 2021 Rev 4.2
Kulicke & Soffa™
SECS/GEM Interface for K&S Ball Bonders
Bonder software version x-xx-x-473-series
IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Collection Events
CEID
Name
Description
9601
AUTO-BONDHEAD-TABLEVIOLATION-CLEAR
Alarm Clear: Bond Head Table Size Violation #254
9610
AUTO-AIR-OUT-OF-LIMITSSET
Alarm Set: Missing air supply #262
9611
AUTO-AIR-OUT-OF-LIMITSCLEAR
Alarm Clear: Missing air supply #262
9620
AUTO-TEMP-OUT-OF-ADRANGE-SET
Alarm Set: Temperature Sensor Out of A-D Range #264
9621
AUTO-TEMP-OUT-OF-ADRANGE-CLEAR
Alarm Clear: Temperature Sensor Out of A-D Range #264
9630
AUTO-TEMP-OUT-OF-ADRANGE-CLXC-SET
Alarm Set: Temperature Sensor for Zone 4 Out of A-D Range
#265
9631
AUTO-TEMP-OUT-OF-ADRANGE-CLXC-CLEAR
Alarm Clear: Temperature Sensor for Zone 4 Out of A-D Range
#265
9640
MHS_WORKHOLDER_NOT
_EMPTY_SET
Alarm Set: Work holder not empty
9641
MHS_WORKHOLDER_NOT
_EMPTY_CLEAR
Alarm Clear: Work holder not empty
9650
MHS_PUL_CARRIER_ALR
EADY_PRESENT_SET
Alarm Set: Leadframe cannot be pulled in - one already present
9651
MHS_PUL_CARRIER_ALR
EADY_PRESENT_CLEAR
Alarm Clear: Leadframe cannot be pulled in - one already
present
9660
FRL_WILL_REACH_LIMIT_I
NDEX-SET
Alarm Clear: Leadframe cannot be pulled in - one already
present
9661
FRL_WILL_REACH_LIMIT_I
NDEX-CLEAR
Alarm Clear: Leadframe cannot be pulled in - one already
present
9670
PUL_HOME_NOT_FOUNDSET
Alarm Set: Puller's home not found
9671
PUL_HOME_NOT_FOUNDCLEAR
Alarm Clear: Puller's home not found
9680
IND_HOME_NOT_FOUNDSET
Alarm Set: Indexer's home not found
9681
IND_HOME_NOT_FOUNDCLEAR
Alarm Clear: Indexer's home not found
9690
FRL_HOME_NOT_FOUNDSET
Alarm Set: Front rail's home not found
9691
FRL_HOME_NOT_FOUNDCLEAR
Alarm Clear: Front rail's home not found
9700
RRL_HOME_NOT_FOUNDSET
Alarm Set: Rear rail's home not found
(U2)
Page - 193 - of 324
Jan 28, 2021 Rev 4.2
Kulicke & Soffa™
SECS/GEM Interface for K&S Ball Bonders
Bonder software version x-xx-x-473-series
IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Collection Events
CEID
Name
Description
9701
RRL_HOME_NOT_FOUNDCLEAR
Alarm Clear: Rear rail's home not found
9710
CI_HOME_NOT_FOUNDSET
Alarm Set: Clamp's home not found
9711
CI_HOME_NOT_FOUNDCLEAR
Alarm Clear: Clamp's home not found
9720
HB_HOME_NOT_FOUNDSET
Alarm Set: Heat block's home not found
9721
HB_HOME_NOT_FOUNDCLEAR
Alarm Clear: Heat block's home not found
9730
GRP_HOME_NOT_FOUNDSET
Alarm Set: Indexer gripper's home not found
9731
GRP_HOME_NOT_FOUNDCLEAR
Alarm Clear: Indexer gripper's home not found
9740
IND_CARRIER_EDGE_NOT
_FOUND-SET
Alarm Set: Lead frame's X registration edge not found
9741
IND_CARRIER_EDGE_NOT
_FOUND-CLEAR
Alarm Clear: Lead frame's X registration edge not found
9750
IND_DEVICE_NOT_FOUND
-SET
Alarm Set: Device's eye point not found
9751
IND_DEVICE_NOT_FOUND
-CLEAR
Alarm Clear: Device's eye point not found
9760
IND_BOND_TEACH_FAILU
RE-SET
Alarm set: teach bonding position failure.
9761
IND_BOND_TEACH_FAILU
RE-CLEAR
Alarm clear: teach bonding position failure.
9770
PUL_CARRIER_NOT_PRE
SENT-SET
Alarm Set: Empty input magazine slot
9771
PUL_CARRIER_NOT_PRE
SENT-CLEAR
Alarm Clear: Empty input magazine slot
9780
PUL_CARRIER_EDGE_NO
T_FOUND-SET
Alarm Set: Lead frame's X registration edge not found
9781
PUL_CARRIER_EDGE_NO
T_FOUND-CLEAR
Alarm Clear: Lead frame's X registration edge not found
9790
MHS_INIT_FAILURE-SET
Alarm Set: MHS initialization failed
9791
MHS_INIT_FAILURECLEAR
Alarm Clear: MHS initialization failed
9800
RAILS_LIMIT_DETECTEDSET
Alarm Set: Rail limit sensor was blocked
(U2)
Page - 194 - of 324
Jan 28, 2021 Rev 4.2
Kulicke & Soffa™
SECS/GEM Interface for K&S Ball Bonders
Bonder software version x-xx-x-473-series
IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Collection Events
CEID
Name
Description
9801
RAILS_LIMIT_DETECTEDCLEAR
Alarm Clear: Rail limit sensor was blocked
9810
FRL_LIMIT_DETECTEDSET
Alarm Set: Front rail limit sensor was blocked
9811
FRL_LIMIT_DETECTEDCLEAR
Alarm Clear: Front rail limit sensor was blocked
9820
RRL_LIMIT_DETECTEDSET
Alarm Set: Rear rail limit sensor was blocked
9821
RRL_LIMIT_DETECTEDCLEAR
Alarm Clear: Rear rail limit sensor was blocked
9830
Y_COOR_EXCEEDS_LIMIT
-SET
Alarm Set: Y correction requested exceeds limit
9831
Y_COOR_EXCEEDS_LIMIT
-CLEAR
Alarm Clear: Y correction requested exceeds limit
9840
X_COOR_EXCEEDS_UPDA
TE_LIMIT-SET
Alarm Set: X correction exceeds update limit
9841
X_COOR_EXCEEDS_UPDA
TE_LIMIT-CLEAR
Alarm Clear: X correction exceeds update limit
9850
Y_COOR_EXCEEDS_UPDA
TE_LIMIT-SET
Alarm Set: Y correction exceeds update limit
9851
Y_COOR_EXCEEDS_UPDA
TE_LIMIT-CLEAR
Alarm Clear: Y correction exceeds update limit
9860
RLS_INDEX_ERROR-SET
Alarm Set: Rail index motion error
9861
RLS_INDEX_ERRORCLEAR
Alarm Clear: Rail index motion error
9870
MH_SLOT_SENSOR_BLOC
KED_NONE_MAG-SET
Alarm Set: Work holder detected slot sensor blocked
9871
MH_SLOT_SENSOR_BLOC
KED_NONE_MAG-CLEAR
Alarm Clear: Work holder detected slot sensor blocked
9880
MH_SLOT_SENSOR_BLOC
KED_NONE_MAG_O-SET
Alarm Set: Work holder detected slot sensor blocked
9881
MH_SLOT_SENSOR_BLOC
KED_NONE_MAG_OCLEAR
Alarm Clear: Work holder detected slot sensor blocked
9890
MH_SLOT_SENSOR_BLOC
KED-SET
Alarm Set: Input Mag Handler detected slot sensor blocked
9891
MH_SLOT_SENSOR_BLOC
KED-CLEAR
Alarm Clear: Input Mag Handler detected slot sensor blocked
9900
MH_SLOT_SENSOR_BLOC
KED_O-SET
Alarm Set: Output Mag Handler detected slot sensor blocked
(U2)
Page - 195 - of 324
Jan 28, 2021 Rev 4.2
Kulicke & Soffa™
SECS/GEM Interface for K&S Ball Bonders
Bonder software version x-xx-x-473-series
IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Collection Events
CEID
Name
Description
9901
MH_SLOT_SENSOR_BLOC
KED_O-CLEAR
Alarm Clear: Output Mag Handler detected slot sensor blocked
9910
MH_Y_SENSOR_FAILURESET
Alarm Set: Input Y motor: motion error or home sensor timeout
9911
MH_Y_SENSOR_FAILURECLEAR
Alarm Clear: Input Y motor: motion error or home sensor timeout
9920
MH_Y_SENSOR_FAILURE_
O-SET
Alarm Set: Output mag handler Y home error
9921
MH_Y_SENSOR_FAILURE_
O-CLEAR
Alarm Clear: Output mag handler Y home error
9930
MH_Z_SENSOR_FAILURESET
Alarm Set: Input mag handler Z home error
9931
MH_Z_SENSOR_FAILURECLEAR
Alarm Clear: Input mag handler Z home error
9940
MH_Z_SENSOR_FAILURE_
O-SET
Alarm Set: Output mag handler Z home error
9941
MH_Z_SENSOR_FAILURE_
O-CLEAR
Alarm Clear: Output mag handler Z home error
9950
RRL_WILL_REACH_LIMIT_I
NDEX-SET
Alarm Set: rear rail will reach limit during device index
9951
RRL_WILL_REACH_LIMIT_I
NDEX-CLEAR
Alarm Clear: rear rail will reach limit during device index
9960
MH_FAILED_STORE_MAGSET
Alarm Set: Input mag handler failed unload
9961
MH_FAILED_STORE_MAGCLEAR
Alarm Clear: Input mag handler failed unload
9970
MH_FAILED_STORE_MAG
_O-SET
Alarm Set: Output mag handler failed unload
9971
MH_FAILED_STORE_MAG
_O-CLEAR
Alarm Clear: Output mag handler failed unload
9980
MH_FAILED_GET_MAGSET
Alarm Set: Input mag handler: Failed to load mag (calibration)
9981
MH_FAILED_GET_MAGCLEAR
Alarm Clear: Input mag handler: Failed to load mag (calibration)
9990
MH_FAILED_GET_MAG_OSET
Alarm Set: Output mag handler: Failed to load mag (calibration)
9991
MH_FAILED_GET_MAG_OCLEAR
Alarm Clear: Output mag handler: Failed to load mag
(calibration)
10000
MH_INPUT_TRAY_EMPTYSET
Alarm Set: Input magazine handler, Load tray is empty
(U2)
Page - 196 - of 324
Jan 28, 2021 Rev 4.2
Kulicke & Soffa™
SECS/GEM Interface for K&S Ball Bonders
Bonder software version x-xx-x-473-series
IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Collection Events
CEID
Name
Description
10001
MH_INPUT_TRAY_EMPTYCLEAR
Alarm Clear: Input magazine handler, Load tray is empty
10010
MH_INPUT_TRAY_EMPTY_
O-SET
Alarm Set: Output magazine handler, Load tray is empty
10011
MH_INPUT_TRAY_EMPTY_
O-CLEAR
Alarm Clear: Output magazine handler, Load tray is empty
10020
MH_OUTPUT_TRAY_FULLSET
Alarm Set: Input magazine handler, tray full sensor detected
10021
MH_OUTPUT_TRAY_FULLCLEAR
Alarm Clear: Input magazine handler, tray full sensor detected
10030
MH_OUTPUT_TRAY_FULL
_O-SET
Alarm Set: Output magazine handler, tray full sensor detected
10031
MH_OUTPUT_TRAY_FULL
_O-CLEAR
Alarm Clear: Output magazine handler, tray full sensor
10040
MH_G_SENSOR_FAILURESET
Alarm Set: Input G motor: motion error or home sensor timeout
10041
MH_G_SENSOR_FAILURECLEAR
Alarm Clear: Input G motor: motion error or home sensor timeout
10050
MH_G_SENSOR_FAILURE
_O-SET
Alarm Set: Output G motor: motion error or home sensor timeout
10051
MH_G_SENSOR_FAILURE
_O-CLEAR
Alarm Clear: Output G motor: motion error or home sensor
timeout
10060
MH_FAILED_OPERATION_
CHESS-SET
Alarm Set: Input magazine handler, Cannot correct the situation
please chess to a safe location
10061
MH_FAILED_OPERATION_
CHESS-CLEAR
Alarm Clear: Input magazine handler, Cannot correct the
situation please chess to a safe location
10070
MH_FAILED_OPERATION_
CHESS_O-SET
Alarm Set: Output magazine handler, Cannot correct the
situation please chess to a safe location
10071
MH_FAILED_OPERATION_
CHESS_O-CLEAR
Alarm Clear: Output magazine handler, Cannot correct the
situation please chess to a safe location
10080
FRL_WILL_REACH_LIMIT_
CORR-SET
Alarm Set: Front rail will reach limit during device correction
10081
FRL_WILL_REACH_LIMIT_
CORR-CLEAR
Alarm Clear: Front rail will reach limit during device correction
10090
RRL_WILL_REACH_LIMIT_
CORR-SET
Alarm Set: Rear rail will reach limit during device correction
10091
RRL_WILL_REACH_LIMIT_
CORR-CLEAR
Alarm Clear: Rear rail will reach limit during device correction
10100
FRL_LIMIT_REACHED_IND
EX-SET
Alarm Set: Front rail reached limit during device index
(U2)
Page - 197 - of 324
Jan 28, 2021 Rev 4.2
Kulicke & Soffa™
SECS/GEM Interface for K&S Ball Bonders
Bonder software version x-xx-x-473-series
IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Collection Events
CEID
Name
Description
10101
FRL_LIMIT_REACHED_IND
EX-CLEAR
Alarm Clear: Front rail reached limit during device index
10110
MH_TRAY_NOT_DETECTE
D-SET
Alarm Set: Input mag handler tray detect sensor not blocked
10111
MH_TRAY_NOT_DETECTE
D-CLEAR
Alarm Clear: Input mag handler tray detect sensor not blocke
10120
MH_TRAY_NOT_DETECTE
D_O-SET
Alarm Set: Output mag handler tray detect sensor not blocked
10121
MH_TRAY_NOT_DETECTE
D_O-CLEAR
Alarm Clear: Output mag handler tray detect sensor not blocked
10130
MH_TRAY_DETECT_SENS
OR_FAILURE-SET
Alarm Set: Input mag handler tray detect sensor state error
10131
MH_TRAY_DETECT_SENS
OR_FAILURE-CLEAR
Alarm Clear: Input mag handler tray detect sensor state error
10140
MH_TRAY_DETECT_SENS
OR_FAILURE_O-SET
Alarm Set: Output mag handler tray detect sensor state error
10141
MH_TRAY_DETECT_SENS
OR_FAILURE_O-CLEAR
Alarm Clear: Output mag handler tray detect sensor state error
10150
MH_GRIP_SENSORS_FAIL
ED-SET
Alarm Set: Input mag handler gripping sensor states not same
10151
MH_GRIP_SENSORS_FAIL
ED-CLEAR
Alarm Clear: Input mag handler gripping sensor states not same
10160
MH_GRIP_SENSORS_FAIL
ED_O-SET
Alarm Set: Output mag handler gripping sensor states not same
10161
MH_GRIP_SENSORS_FAIL
ED_O-CLEAR
Alarm Clear: Output mag handler gripping sensor states not
same
10170
MH_GRIP_ACTIVE_INVALI
D-SET
Alarm Set: Input mag handler grip sensor blocked
10171
MH_GRIP_ACTIVE_INVALI
D-CLEAR
Alarm Clear: Input mag handler grip sensor blocked
10180
MH_GRIP_ACTIVE_INVALI
D_O-SET
Alarm Set: Output mag handler grip sensor blocked
10181
MH_GRIP_ACTIVE_INVALI
D_O-CLEAR
Alarm Clear: Output mag handler grip sensor blocked
10190
MH_TOUCH_ACTIVE_INVA
LID-SET
Alarm Set: Input mag handler touch sensor blocked
10191
MH_TOUCH_ACTIVE_INVA
LID-CLEAR
Alarm Clear: Input mag handler touch sensor blocked
10200
MH_TOUCH_ACTIVE_INVA
LID_O-SET
Alarm Set: Output mag handler touch sensor blocked
(U2)
Page - 198 - of 324
Jan 28, 2021 Rev 4.2
Kulicke & Soffa™
SECS/GEM Interface for K&S Ball Bonders
Bonder software version x-xx-x-473-series
IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Collection Events
CEID
Name
Description
10201
MH_TOUCH_ACTIVE_INVA
LID_O-CLEAR
Alarm Clear: Output mag handler touch sensor blocked
10210
MH_STATE_BAD_SENSOR
S_GRIP-SET
Alarm Set: Input mag handler gripping sensors blocked
10211
MH_STATE_BAD_SENSOR
S_GRIP-CLEAR
Alarm Clear: Input mag handler gripping sensors blocked
10220
MH_STATE_BAD_SENSOR
S_GRIP_O-SET
Alarm Set: Output mag handler gripping sensors blocked
10221
MH_STATE_BAD_SENSOR
S_GRIP_O-CLEAR
Alarm Clear: Output mag handler gripping sensors blocked
10230
MH_FAILED_GET_MAGSET
Alarm Set: Input mag handler: Fail to load mag (setup)
10231
MH_FAILED_GET_MAGCLEAR
Alarm Clear: Input mag handler: Fail to load mag (setup)
10240
MH_FAILED_GET_MAG_OSET
Alarm Set: Output mag handler: Fail to load mag (setup)
10241
MH_FAILED_GET_MAG_OCLEAR
Alarm Clear: Output mag handler: Fail to load mag (setup)
10250
MH_STORE_SENSOR_ER
ROR-SET
Alarm Set: Input mag handler tray full or detect sensor blocked
10251
MH_STORE_SENSOR_ER
ROR-CLEAR
Alarm Clear: Input mag handler tray full or detect sensor blocked
10260
MH_STORE_SENSOR_ER
ROR_O-SET
Alarm Set: Output mag handler tray full or detect sensor blocked
10261
MH_STORE_SENSOR_ER
ROR_O-CLEAR
Alarm Clear: Output mag handler tray full or detect sensor
blocked
10270
MH_TRAY_ERROR_IN_LO
AD-SET
Alarm Set: A magazine was illegally place on the input mag's
load tray or it was illegally taken off
10271
MH_TRAY_ERROR_IN_LO
AD-CLEAR
Alarm Clear: A magazine was illegally place on the input mag's
load tray or it was illegally taken off
10280
MH_TRAY_ERROR_IN_UN
LOAD-SET
Alarm Set: A magazine was illegally place on the Input Mag's
unload tray or it was illegally taken off
10281
MH_TRAY_ERROR_IN_UN
LOAD-CLEAR
Alarm Clear: A magazine was illegally place on the Input Mag's
unload tray or it was illegally taken off
10290
MH_TRAY_ERROR_OUT_L
OAD-SET
Alarm Set: A magazine was illegally place on the Output Mag's
load tray or it was illegally taken off
10291
MH_TRAY_ERROR_OUT_L
OAD-CLEAR
Alarm Clear: A magazine was illegally place on the Output Mag's
load tray or it was illegally taken off
10300
MH_TRAY_ERROR_OUT_U
NLOAD-SET
Alarm Set: A magazine was illegally place on the Output Mag's
unload tray or it was illegally taken off
(U2)
Page - 199 - of 324
Jan 28, 2021 Rev 4.2
Kulicke & Soffa™
SECS/GEM Interface for K&S Ball Bonders
Bonder software version x-xx-x-473-series
IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Collection Events
CEID
Name
Description
10301
MH_TRAY_ERROR_OUT_U
NLOAD-CLEAR
Alarm Clear: A magazine was illegally place on the Output Mag's
unload tray or it was illegally taken off
10310
MHS_IND_AXIS_LIMIT_ER
ROR-SET
Alarm Set: Indexer Motion interrupted
10311
MHS_IND_AXIS_LIMIT_ER
ROR-CLEAR
Alarm Clear: Indexer Motion interrupted
10320
MHS_IND_JAM_RELIEF_E
RROR-SET
Alarm Set: Jam transducer decompression failure
10321
MHS_IND_JAM_RELIEF_E
RROR-CLEAR
Alarm Clear: Jam transducer decompression failure
10330
RRL_LIMIT_REACHED_IND
EX-SET
Alarm Set: Rear rail reached limit during device index
10331
RRL_LIMIT_REACHED_IND
EX-CLEAR
Alarm Clear: Rear rail reached limit during device index
10340
FRL_LIMIT_REACHED_CO
RR-SET
Alarm Set: Front rail reached limit during device correction
10341
FRL_LIMIT_REACHED_CO
RR-CLEAR
Alarm Clear: Front rail reached limit during device correction
10350
RRL_LIMIT_REACHED_CO
RR-SET
Alarm Set: Rear limit reached limit during device correction
10351
RRL_LIMIT_REACHED_CO
RR-CLEAR
Alarm Clear: Rear limit reached limit during device correction
10360
FRL_LIMIT_REACHED_CY
CLE-SET
Alarm Set: Front rail reached limit during cycling
10361
FRL_LIMIT_REACHED_CY
CLE-CLEAR
Alarm Clear: Front rail reached limit during cycling
10370
RRL_LIMIT_REACHED_CY
CLE-SET
Alarm Set: Rear rail reached limit during cycling
10371
RRL_LIMIT_REACHED_CY
CLE-CLEAR
Alarm Clear: Rear rail reached limit during cycling
10380
FRL_WILL_REACH_LIMIT_
SETUP-SET
Alarm Set: Front rail will reach limit during setup
10381
FRL_WILL_REACH_LIMIT_
SETUP-CLEAR
Alarm Clear: Front rail will reach limit during setup
10390
RRL_WILL_REACH_LIMIT_
SETUP-SET
Alarm Set: Rear rail will reach limit during setup
10391
RRL_WILL_REACH_LIMIT_
SETUP-CLEAR
Alarm Clear: Rear rail will reach limit during setup
10400
PUL_NOT_OUT_OF_HOME
-SET
Alarm Set: Puller is not out of home
(U2)
Page - 200 - of 324
Jan 28, 2021 Rev 4.2
Kulicke & Soffa™
SECS/GEM Interface for K&S Ball Bonders
Bonder software version x-xx-x-473-series
IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Collection Events
CEID
Name
Description
10401
PUL_NOT_OUT_OF_HOME
-CLEAR
Alarm Clear: Puller is not out of home
10410
IND_NOT_OUT_OF_HOMESET
Alarm Set: Indexer is not out of home
10411
IND_NOT_OUT_OF_HOMECLEAR
Alarm Clear: Indexer is not out of home
10420
FRL_NOT_OUT_OF_HOME
-SET
Alarm Set: Front rail is not out of home
10421
FRL_NOT_OUT_OF_HOME
-CLEAR
Alarm Clear: Front rail is not out of home
10430
RRL_NOT_OUT_OF_HOME
-SET
Alarm Set: Rear rail is not out of home
10431
RRL_NOT_OUT_OF_HOME
-CLEAR
Alarm Clear: Rear rail is not out of home
10440
CI_NOT_OUT_OF_HOMESET
Alarm Set: Clamp is not out of home
10441
CI_NOT_OUT_OF_HOMECLEAR
Alarm Clear: Clamp is not out of home
10450
HB_NOT_OUT_OF_HOMESET
Alarm Set: Heat block is not out of home
10451
HB_NOT_OUT_OF_HOMECLEAR
Alarm Clear: Heat block is not out of home
10460
GRP_NOT_OUT_OF_HOM
E-SET
Alarm Set: Indexer gripper is not out of home
10461
GRP_NOT_OUT_OF_HOM
E-CLEAR
Alarm Clear: Indexer gripper is not out of home
10470
IND_RECOVERY-SET
Alarm Set: Index sequence aborted
10471
IND_RECOVERY-CLEAR
Alarm Clear: Index sequence aborted
10480
IND_REMOVE_CRR-SET
Alarm Set: Remove leadframe from the rails
10481
IND_REMOVE_CRRCLEAR
Alarm Clear: Remove leadframe from the rails
10490
CORR_IFR_WITH_PREBO
ND_CRR-SET
Alarm Set: Correction will interfere with pre-bond leadframe
10491
CORR_IFR_WITH_PREBO
ND_CRR-CLEAR
Alarm Clear: Correction will interfere with pre-bond leadframe
10500
RLS_CORRECT_ERRORSET
Alarm Set: Rail correction motion error
10501
RLS_CORRECT_ERRORCLEAR
Alarm Clear: Rail correction motion error
(U2)
Page - 201 - of 324
Jan 28, 2021 Rev 4.2
Kulicke & Soffa™
SECS/GEM Interface for K&S Ball Bonders
Bonder software version x-xx-x-473-series
IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Collection Events
CEID
Name
Description
10510
WHL_HAS_DEVICE_CLAM
PED-SET
Alarm Set: There is a clamped device present and operation will
release this device
10511
WHL_HAS_DEVICE_CLAM
PED-CLEAR
Alarm Clear: There is a clamped device present and operation
will release this device
10520
MH_INIT_CANNOT_STORE
_MAGAZINE-SET
Alarm Set: Cannot unload magazine so cannot properly complete
the init operation
10521
MH_INIT_CANNOT_STORE
_MAGAZINE-CLEAR
Alarm Clear: Cannot unload magazine so cannot properly
complete the init operation
10530
MH_CHESS_TO_SAFE_LO
CATION-SET
Alarm Set: Lost power fail data must chess out to safe location
10531
MH_CHESS_TO_SAFE_LO
CATION-CLEAR
Alarm Clear: Lost power fail data must chess out to safe location
10540
MH_DROP_MAGAZINESET
Alarm Set: MH magazine will be dropped
10541
MH_DROP_MAGAZINECLEAR
Alarm Clear: MH magazine will be dropped
10550
MH_MUST_ALSO_HOME_
Y_MOTOR-SET
Alarm Set: Home operation on Input magazine handler will also
Home the Y motor since damage to the trays could result
otherwise
10551
MH_MUST_ALSO_HOME_
Y_MOTOR-CLEAR
Alarm Clear: Home operation on Input magazine handler will also
Home the Y motor since damage to the trays could result
otherwise
10560
MH_MUST_ALSO_HOME_
Y_MOTOR_O-SET
Alarm Set: Home operation on Output magazine handler will also
home the Y motor since damage to the trays could result
otherwise
10561
MH_MUST_ALSO_HOME_
Y_MOTOR_O-CLEAR
Alarm Clear: Home operation on Output magazine handler will
also home the Y motor since damage to the trays could result
otherwise
10570
MH_HOME_G_MUST_HOM
E_Y_MOTOR-SET
Alarm Set: Homing the gripper on the Input magazine handler
while in the tray area could damage the trays
10571
MH_HOME_G_MUST_HOM
E_Y_MOTOR-CLEAR
Alarm Clear: Homing the gripper on the Input magazine handler
while in the tray area could damage the trays
10580
MH_HOME_G_MUST_HOM
E_Y_MOTOR_O-SET
Alarm Set: Homing the gripper on the Output magazine handler
while in the tray area could damage the trays
10581
MH_HOME_G_MUST_HOM
E_Y_MOTOR_O-CLEAR
Alarm Clear: Homing the gripper on the Output magazine handler
while in the tray area could damage the trays
10590
MH_HOME_G_MUST_HOM
E_Z_MOTOR-SET
Alarm Set: Homing the gripper motor on the Input magazine
handler may damage the handler so must first home the Z motor
10591
MH_HOME_G_MUST_HOM
E_Z_MOTOR-CLEAR
Alarm Clear: Homing the gripper motor on the Input magazine
handler may damage the handler so must first home the Z motor
(U2)
Page - 202 - of 324
Jan 28, 2021 Rev 4.2
Kulicke & Soffa™
SECS/GEM Interface for K&S Ball Bonders
Bonder software version x-xx-x-473-series
IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Collection Events
CEID
Name
Description
10600
MH_HOME_G_MUST_HOM
E_Z_MOTOR_O-SET
Alarm Set: Homing the gripper motor on the Output magazine
handler may damage the handler so must first home the Z motor.
10601
MH_HOME_G_MUST_HOM
E_Z_MOTOR_O-CLEAR
Alarm Clear: Homing the gripper motor on the Output magazine
handler may damage the handler so must first home the Z motor.
10610
MH_HOME_GRIPPER_DR
OP_MAG-SET
Alarm Set: Homing the gripper on the Input magazine handler will
drop the magazine
10611
MH_HOME_GRIPPER_DR
OP_MAG-CLEAR
Alarm Clear: Homing the gripper on the Input magazine handler
will drop the magazine
10620
MH_HOME_GRIPPER_DR
OP_MAG_O-SET
Alarm Set: Homing the gripper on the Output magazine handler
will drop the magazine
10621
MH_HOME_GRIPPER_DR
OP_MAG_O-CLEAR
Alarm Clear: Homing the gripper on the Output magazine handler
will drop the magazine
10630
MH_INVALID_GRIP_STATE
-SET
Alarm Set: Input magazine handler state says gripped yet touch
and grip sensor are not both active
10631
MH_INVALID_GRIP_STATE
-CLEAR
Alarm Clear: Input magazine handler state says gripped yet
touch and grip sensor are not both active
10640
MH_INVALID_GRIP_STATE
_O-SET
Alarm Set: Output magazine handler state says gripped yet touch
and grip sensor are not both active
10641
MH_INVALID_GRIP_STATE
_O-CLEAR
Alarm Clear: Output magazine handler state says gripped yet
touch and grip sensor are not both active
10650
MH_INVALID_UNGRIP_ST
ATE-SET
Alarm Set: Input magazine handler state stays ungripped yet
touch and/or grip sensor are active
10651
MH_INVALID_UNGRIP_ST
ATE-CLEAR
Alarm Clear: Input magazine handler state stays ungripped yet
touch and/or grip sensor are active
10660
MH_INVALID_UNGRIP_ST
ATE_O-SET
Alarm Set: Output magazine handler state stays ungripped yet
touch and/or grip sensor are active
10661
MH_INVALID_UNGRIP_ST
ATE_O-CLEAR
Alarm Clear: Output magazine handler state stays ungripped yet
touch and/or grip sensor are active
10670
MH_TRAY_DETECT-SET
Alarm Set: Input magazine handler, tray detect sensor active at
invalid location, Invalid sensor condition
10671
MH_TRAY_DETECTCLEAR
Alarm Clear: Input magazine handler, tray detect sensor active at
invalid location, Invalid sensor condition
10680
MH_TRAY_DETECT_OSET
Alarm Set: Output magazine handler, tray detect sensor active at
invalid location, Invalid sensor condition
10681
MH_TRAY_DETECT_OCLEAR
Alarm Clear: Output magazine handler, tray detect sensor active
at invalid location, Invalid sensor condition
10690
MH_GRIP_ACTIVE_INVALI
D_ABORT-SET
Alarm Set: Input mag handler grip sensor blocked
10691
MH_GRIP_ACTIVE_INVALI
D_ABORT-CLEAR
Alarm Clear: Input mag handler grip sensor blocked
(U2)
Page - 203 - of 324
Jan 28, 2021 Rev 4.2
Kulicke & Soffa™
SECS/GEM Interface for K&S Ball Bonders
Bonder software version x-xx-x-473-series
IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Collection Events
CEID
Name
Description
10700
MH_GRIP_ACTIVE_INVALI
D_ABORT_O-SET
Alarm Set: Output mag handler grip sensor blocked
10701
MH_GRIP_ACTIVE_INVALI
D_ABORT_O-CLEAR
Alarm Clear: Output mag handler grip sensor blocked
10710
MH_TOUCH_ACTIVE_INVA
LID_ABORT-SET
Alarm Set: Input mag handler touch sensor blocked
10711
MH_TOUCH_ACTIVE_INVA
LID_ABORT-CLEAR
Alarm Clear: Input mag handler touch sensor blocked
10730
MH_STATE_BAD_SENSOR
S_GRIP_ABORT-SET
Alarm Set: Input magazine handler state reports ungripped, and
sensors report a magazine is gripped
10731
MH_STATE_BAD_SENSOR
S_GRIP_ABORT-CLEAR
Alarm Clear: Input magazine handler state reports ungripped,
and sensors report a magazine is gripped
10740
MH_STATE_BAD_SENSOR
S_GRIP_ABORT_O-SET
Alarm Set: Output magazine handler state reports ungripped,
and sensors report a magazine is gripped
10741
MH_STATE_BAD_SENSOR
S_GRIP_ABORT_O-CLEAR
Alarm Clear: Output magazine handler state reports ungripped,
and sensors report a magazine is gripped
10750
MH_OP_SUSPEND-SET
Alarm Set: Input mag handler: Operation Suspended
10751
MH_OP_SUSPEND-CLEAR
Alarm Clear: Input mag handler: Operation Suspended
10760
MH_OP_SUSPEND_O-SET
Alarm Set: Output mag handler: Operation Suspended
10761
MH_OP_SUSPEND_OCLEAR
Alarm Clear: Output mag handler: Operation Suspended
10770
MH_I_OP_WARN-SET
Alarm Set: Input mag handler: Mag Interference Possible
10771
MH_I_OP_WARN-CLEAR
Alarm Clear: Input mag handler: Mag Interference Possible
10780
MH_O_OP_WARN-SET
Alarm Set: Output mag handler: Mag Interference Possible
10781
MH_O_OP_WARN-CLEAR
Alarm Clear: Output mag handler: Mag Interference Possible
10790
MH_TEACH_TOO_MUCH_
ROTATION-SET
Alarm Set: Too much rotation found when teaching magazine
10791
MH_TEACH_TOO_MUCH_
ROTAION-CLEAR
Alarm Clear: Too much rotation found when teaching magazine
10800
MH_TEACH_OPERATION_
FAILED-SET
Alarm Set: Teach operation failed
10801
MH_TEACH_OPERATION_
FAILED-CLEAR
Alarm Clear: Teach operation failed
10810
MH_CAL_SLOT_OPERATI
ON_FAILED-SET
Alarm Set: Calibrate slot operation failed
10811
MH_CAL_SLOT_OPERATI
ON_FAILED-CLEAR
Alarm Clear: Calibrate slot operation failed
10820
MH_CAL_TRAY_OPERATI
ON_FAILED-SET
Alarm Set: Calibrate tray operation failed
(U2)
Page - 204 - of 324
Jan 28, 2021 Rev 4.2
Kulicke & Soffa™
SECS/GEM Interface for K&S Ball Bonders
Bonder software version x-xx-x-473-series
IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Collection Events
CEID
Name
Description
10821
MH_CAL_TRAY_OPERATI
ON_FAILED-CLEAR
Alarm Clear: Calibrate tray operation failed
10830
IND_THETA_EXTEND_FAIL
URE-SET
Alarm Set: Theta bar not extended due to indexer's position
10831
IND_THETA_EXTEND_FAIL
URE-CLEAR
Alarm Clear: Theta bar not extended due to indexer's position
10840
MHS_JDC_CMD_FAILURESET
Alarm Set: Jam Detect command failed
10841
MHS_JDC_CMD_FAILURECLEAR
Alarm Clear: Jam Detect command failed
10850
MHS_JDC_DIAG_FAILURESET
Alarm Set: Jam Detect diagnostic failed - do calibration
10851
MHS_JDC_DIAG_FAILURECLEAR
Alarm Clear: Jam Detect diagnostic failed - do calibration
10860
MHS_JDC_INIT_FAILURESET
Alarm Set: Work holder JDC cross load failed
10861
MHS_JDC_INIT_FAILURECLEAR
Alarm Clear: Work holder JDC cross load failed
10870
PUL_Y_REGISTRATION_F
AILURE-SET
Alarm Set: Lead frame's Y registration edge not found
10871
PUL_Y_REGISTRATION_F
AILURE-CLEAR
Alarm Clear: Lead frame's Y registration edge not found
10880
PUL_CARRIER_MISSINGSET
Alarm Set: leadframe is not present on the work holder
10881
PUL_CARRIER_MISSINGCLEAR
Alarm Clear: leadframe is not present on the work holder
10890
PUL_Y_REGISTRATION_A
CTIVE-SET
Alarm Set: Y registration sensor is already blocked
10891
PUL_Y_REGISTRATION_A
CTIVE-CLEAR
Alarm Clear: Y registration sensor is already blocked
10900
MHS_INDEXER_CALIBRAT
ION_UNSUCCESSFUL-SET
Alarm Set: Indexer calibration terminated
10901
MHS_INDEXER_CALIBRAT
ION_UNSUCCESSFULCLEAR
Alarm Clear: Indexer calibration terminated
10910
MHS_CLAMP_CALIBRATIO
N_UNSUCCESSFUL-SET
Alarm Set: Clamp calibration terminated
10911
MHS_CLAMP_CALIBRATIO
N_UNSUCCESSFULCLEAR
Alarm Clear: Clamp calibration terminated
(U2)
Page - 205 - of 324
Jan 28, 2021 Rev 4.2
Kulicke & Soffa™
SECS/GEM Interface for K&S Ball Bonders
Bonder software version x-xx-x-473-series
IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Collection Events
CEID
Name
Description
10920
MHS_RAILS_CALIBRATION
_UNSUCCESSFUL-SET
Alarm Set: Rails calibration terminated
10921
MHS_RAILS_CALIBRATION
_UNSUCCESSFUL-CLEAR
Alarm Clear: Rails calibration terminated
10930
MHS_X_SENSOR_CALIBR
ATION_UNSUCCESSFULSET
Alarm Set: Work holder X sensor calibration terminated
10931
MHS_X_SENSOR_CALIBR
ATION_UNSUCCESSFULCLEAR
Alarm Clear: Work holder X sensor calibration terminated
10940
MHS_CAL_TUCKER_EJEC
T_OPERATION_FAILEDSET
Alarm Set: Indexer tucker eject calibration terminated
10941
MHS_CAL_TUCKER_EJEC
T_OPERATION_FAILEDCLEAR
Alarm Clear: Indexer tucker eject calibration terminated
10950
MHS_JAM_CALIBRATION_
UNSUCCESSFUL-SET
Alarm Set: Jam detect calibration terminated
10951
MHS_JAM_CALIBRATION_
UNSUCCESSFUL-CLEAR
Alarm Clear: Jam detect calibration terminated
10960
MHS_IN_BCR_FAIL-SET
Alarm Set:Input Magazine Barcode read fail
10961
MHS_IN_BCR_FAIL-CLEAR
Alarm Clear: Input Magazine Barcode read fail
10970
MHS_OUT_BCR_FAIL-SET
Alarm Set:Output Magazine Barcode read fail
10971
MHS_OUT_BCR_FAILCLEAR
Alarm Clear: Output Magazine Barcode read fail
10980
AUTO_INVALID_MAG-SET
Alarm Set:Invalid Magazine
10981
AUTO_INVALID_MAGCLEAR
Alarm Clear: Invalid Magazine
10990
PBI-UNIT-STOP-ERR-SET
Alarm set: out of tolerance detected during Post Bond Inspection.
10991
PBI-UNIT-STOP-ERRCLEAR
Alarm clear: out of tolerance detected during Post Bond
Inspection.
11000
AUTO-LEAD-BPC-ERR-SET
Alarm set: Bond proximity check failed
11001
AUTO_LEAD_BPC_ERROR
-CLEAR
Alarm clear: Bond proximity check cleared
11010
AUTO-USG-IMPEDANCECAL-FAIL-SET
Alarm set: AUTO-USG-IMPEDANCE-CAL-FAIL
11011
AUTO-USG-IMPEDANCECAL-FAIL-CLEAR
Alarm clear: AUTO-USG-IMPEDANCE-CAL-FAIL
11020
AUTO-USG-IMPEDANCEOUT-LIMIT-SET
Alarm set: AUTO-USG-IMPEDANCE-OUT-LIMIT
(U2)
Page - 206 - of 324
Jan 28, 2021 Rev 4.2
Kulicke & Soffa™
SECS/GEM Interface for K&S Ball Bonders
Bonder software version x-xx-x-473-series
IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Collection Events
CEID
Name
Description
11021
AUTO-USG-IMPEDANCEOUT-LIMIT-CLEAR
Alarm clear:AUTO-USG-IMPEDANCE-OUT-LIMIT
11040
TEMPERATURE_AUTO_TU
NE_FAIL-SET
Alarm set: Auto tuning of the heat block temperature failure
11041
TEMPERATURE_AUTO_TU
NE_FAIL_CLEAR
Alarm clear: Auto tuning of the heat block temperature failure
11050
AUTO-CU-COVER-GASPRESSURE-OUT-LIMITSET
Alarm set: Nitrogen gas flow out of tolerance
11051
AUTO-CU-COVER-GASPRESSURE-OUT-LIMITCLEAR
Alarm clear: Nitrogen gas flow out of tolerance
11060
X_Y_TABLE_LIMITS-SET
Alarm set: X or Y table limits are unacceptable
11061
X_Y_TABLE_LIMITSCLEAR
Alarm clear: X or Y table limits are unacceptable
11070
AUTO-VLL-FM-DETECTEDSET
Alarm set: Auto VLL foreign material detected
11071
AUTO-VLL-FM-DETECTEDCLEAR
Alarm clear: Auto VLL foreign material detected
11080
AUTO-OVERLAPPED-DIESSET
Alarm set: There are overlapped dies
11081
AUTO-OVERLAPPED-DIESCLEAR
Alarm clear: There are overlapped dies
11090
AUTO-ALIGN-REFDRIFTFAIL-SET
Alarm set: AUTO-ALIGN-REFDRIFT-FAIL.
11091
AUTO-ALIGN-REFDRIFTFAIL-Clear
Alarm clear: AUTO-ALIGN-REFDRIFT-FAIL.
11100
AUTO_BOND_COUNT_RE
ACHING_LIMIT_Set
Alarm set: AUTO_BOND_COUNT_REACHING_LIMIT.
11101
AUTO_BOND_COUNT_RE
ACHING_LIMIT_Clear
Alarm clear: AUTO_BOND_COUNT_REACHING_LIMIT.
11110
AUTO_BOND_COUNT_RE
ACHING_LIMIT_NOWAIT_S
et
Alarm set: AUTO_BOND_COUNT_REACHING_LIMIT_NOWAIT
11111
AUTO_BOND_COUNT_RE
ACHING_LIMIT_NOWAIT_C
lear
Alarm clear:
AUTO_BOND_COUNT_REACHING_LIMIT_NOWAIT
11120
PDT-BONDHEIGHTERROR-Set
Alarm set: PDT-BONDHEIGHT-ERROR.
11121
PDT-BONDHEIGHTERROR-Clear
Alarm clear: PDT-BONDHEIGHT-ERROR.
(U2)
Page - 207 - of 324
Jan 28, 2021 Rev 4.2
Kulicke & Soffa™
SECS/GEM Interface for K&S Ball Bonders
Bonder software version x-xx-x-473-series
IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Collection Events
CEID
Name
Description
11130
ZTC-OUT-OF-LIMITS-Set
Alarm set: ZTC-OUT-OF-LIMITS.
11131
ZTC-OUT-OF-LIMITS-Clear
Alarm clear: ZTC-OUT-OF-LIMITS.
11150
CAP_CLEAN_TAPE_USAG
E_EXCEED_LIMIT-SET
Alarm set: CAP_CLEAN_TAPE_USAGE_EXCEED_LIMIT.
11151
CAP_CLEAN_TAPE_USAG
E_EXCEED_LIMIT-ClEAR
Alarm clear: CAP_CLEAN_TAPE_USAGE_EXCEED_LIMIT.
11160
EH-PDT-SMBALL-SET
Alarm Set: PDT Small Ball Set
11161
EH-PDT-SMBALL-CLEAR
Alarm Clear: PDT Small Ball Clear
11170
PDT-UNEXPECTED-NSOPTOL-SET
Alarm Set: PDT Unexpected NSOP TOL Set
11171
PDT-UNEXPECTED-NSOPTOL-CLEAR
Alarm Clear: PDT Unexpected NSOP TOL Clear
11180
PBI-REALIGN-FAILURESET
Alarm Set: PBI Realign Failure Set
11181
PBI-REALIGN-FAILURECLEAR
Alarm Clear: PBI Realign Failure Clear
11190
CAP_CLEANING_LIMIT_EX
CEEDED-SET
Alarm Set: Set Cap Clean Exceeded Limit
11191
CAP_CLEANING_LIMIT_EX
CEEDED-CLEAR
Alarm Clear: Clear Cap Clean Exceeded Limit
11200
BONDSITE_CHKSUM_FAIL
-SET
Alarm Set: Bond Site Check Sum Fail Set
11201
BONDSITE_CHKSUM_FAIL
-CLEAR
Alarm Clear: Bond Site Check Sum Failure Clear
11210
REF_SYS_XHAIR_OFFSET
_FAIL-SET
Alarm Set: Ref Sys Xhair Offset Fail
11211
REF_SYS_XHAIR_OFFSET
_FAIL-CLEAR
Alarm Clear: Ref Sys Xhair Offset Fail
11220
MH_WAIT_GET_MAG-SET
Alarm Set: MH Wait Get Mag
11221
MH_WAIT_GET_MAGCLEAR
Alarm Clear: MH Wait Ge Mag
11230
MH_WAIT_GET_MAG_OSET
Alarm Set: MH Wait Get Mag Output
11231
MH_WAIT_GET_MAG_OCLEAR
Alarm Clear: MH Wait Get Mag Output
11240
STRIP_ID_NOT_FOUNDSET
Alarm Set: Strip ID Not Found
11241
STRIP_ID_NOT_FOUNDCLEAR
Alarm Clear: Strip ID Not Found
(U2)
Page - 208 - of 324
Jan 28, 2021 Rev 4.2
Kulicke & Soffa™
SECS/GEM Interface for K&S Ball Bonders
Bonder software version x-xx-x-473-series
IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Collection Events
CEID
Name
Description
11250
MH_WT_HOST_RETRY_XC
EED-SET
Alarm Set: MH_WT_HOST_RETRY_XCEED
11251
MH_WT_HOST_RETRY_XC
EED-CLEAR
Alarm Clear: MH_WT_HOST_RETRY_XCEED
11260
MH_WT_HOST_RETRY_XC
EED_O-SET
Alarm Set: MH_WT_HOST_RETRY_XCEED_O
11261
MH_WT_HOST_RETRY_XC
EED_O-CLEAR
Alarm Clear: MH_WT_HOST_RETRY_XCEED_O
11270
EH_SUB_VALIDATION_TIM
EOUT-SET
Alarm Set: EH_SUB_VALIDATION_TIMEOUT
11271
EH_SUB_VALIDATION_TIM
EOUT-CLEAR
Alarm Clear: EH_SUB_VALIDATION_TIMEOUT
11280
MHS_IN_BCR_REJECT_ER
ROR-SET
Alarm Set: MHS_IN_BCR_REJECT_ERROR
11281
MHS_IN_BCR_REJECT_ER
ROR-CLEAR
Alarm Clear: MHS_IN_BCR_REJECT_ERROR
11290
MHS_OUT_BCR_REJECT_
ERROR-SET
Alarm Set: MHS_OUT_BCR_REJECT_ERROR
11291
MHS_OUT_BCR_REJECT_
ERROR-CLEAR
Alarm Clear: MHS_OUT_BCR_REJECT_ERROR
11300
EH_SUB_VALIDATION_RE
JECTED-SET
Alarm Set: EH_SUB_VALIDATION_REJECTED
11301
EH_SUB_VALIDATION_RE
JECTED-CLEAR
Alarm Clear: EH_SUB_VALIDATION_REJECTED
11310
EH_EVENT_COUNT_THRE
SHOLD_EXCEEDED-SET
Alarm Set: EH_EVENT_COUNT_THRESHOLD_EXCEEDED
11311
EH_EVENT_COUNT_THRE
SHOLD_EXCEEDEDCLEAR
Alarm Clear: EH_EVENT_COUNT_THRESHOLD_EXCEEDED
11320
AUTO_USG_LOCK_FREQ_
DRIFT-SET
Alarm Set: Auto USG Lock FREQ Drift
11321
AUTO_USG_LOCK_FREQ_
DRIFT-CLEAR
Alarm clear: Auto USG Lock FREQ Drift
11330
EH_EVENT_COUNT_STOP
_AUTO-SET
Alarm Set: EH Event Count Stop Auto
11331
EH_EVENT_COUNT_STOP
_AUTO-CLEAR
Alarm clear: EH Event Count Stop Auto
11340
PDT-MOTION-TIMEOUTSET
Alarm Set: PDT Motion Time Out
11341
PDT-MOTION-TIMEOUTCLEAR
Alarm clear: PDT Motion Time Out
(U2)
Page - 209 - of 324
Jan 28, 2021 Rev 4.2
Kulicke & Soffa™
SECS/GEM Interface for K&S Ball Bonders
Bonder software version x-xx-x-473-series
IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Collection Events
CEID
Name
Description
11350
PDT-AWAIT-TIMEOUT-SET
Alarm Set: PDT Await Time Out
11351
PDT-AWAIT-TIMEOUTCLEAR
Alarm clear: PDT Await Time Out
11360
PDT-CALLBACKREGISTRATION-SET
Alarm Set: PDT Callback Registration
11361
PDT-CALLBACKREGISTRATION-CLEAR
Alarm clear: PDT Callback Registration
11370
WARNING_EFO_NOT_HAZ
ARD-SET
Alarm Set: Warning EFO Not Hazard
11371
WARNING_EFO_NOT_HAZ
ARD-CLEAR
Alarm clear: Warning EFO Not Hazard
11380
PDT-EFO-INVALID-DATASET
Alarm Set: PDT EFO Invalid Data
11381
PDT-EFO-INVALID-DATACLEAR
Alarm clear: PDT EFO Invalid Data
11390
EH-PDT-BUMP-LIFT-SET
Alarm Set: EH PDT Bump Lift
11391
EH-PDT-BUMP-LIFTCLEAR
Alarm clear: EH PDT Bump Lift
11400
EFO-BOX-COM-ERRORSET
Alarm Set: EFO Box COM Error
11401
EFO-BOX-COM-ERRORCLEAR
Alarm clear: EFO Box COM Error
11410
EFO-RESOURCE-NOTAVAILABLE-SET
Alarm Set: EFO Resource Not Available
11411
EFO-RESOURCE-NOTAVAILABLE-CLEAR
Alarm clear: EFO Resource Not Available
11420
PDT-NO-TIMERS-SET
Alarm Set: PDT No Timers
11421
PDT-NO-TIMERS-CLEAR
Alarm clear: PDT No Timers
11430
PDT-NO-FS-DETECT-SET
Alarm Set: PDT No FS Detect
11431
PDT-NO-FS-DETECTCLEAR
Alarm clear: PDT No FS Detect
11440
PDT-BITS-CAL-ERRORSET
Alarm Set: PDT BITS Cal Error
11441
PDT-BITS-CAL-ERRORCLEAR
Alarm clear: PDT BITS Cal Error
11450
PDT-DIE-MISSING-SET
Alarm Set: PDT Die Missing
11451
PDT-DIE-MISSING-CLEAR
Alarm clear: PDT Die Missing
11460
PDT-UNEXPECTED-LGTLSET
Alarm Set: PDT Unexpected LGTL
(U2)
Page - 210 - of 324
Jan 28, 2021 Rev 4.2
Kulicke & Soffa™
SECS/GEM Interface for K&S Ball Bonders
Bonder software version x-xx-x-473-series
IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Collection Events
CEID
Name
Description
11461
PDT-UNEXPECTED-LGTLCLEAR
Alarm clear: PDT Unexpected LGTL
11470
PDT-UNEXPECTED-NSOPBY-PRS-SET
Alarm Set: PDT Unexpected NSOP By PRS
11471
PDT-UNEXPECTED-NSOPBY-PRS-CLEAR
Alarm clear: PDT Unexpected NSOP By PRS
11480
MANUAL-UNEXPECTEDNSOP-SET
Alarm Set: Manual Unexpected NSOP
11481
MANUAL-UNEXPECTEDNSOP-CLEAR
Alarm clear: Manual Unexpected NSOP
11490
MANUAL-UNEXPECTEDNSOL-SET
Alarm Set: Manual Unexpected NSOL
11491
MANUAL-UNEXPECTEDNSOL-CLEAR
Alarm clear: Manual Unexpected NSOL
11500
MANUAL-UNEXPECTEDSHTL-SET
Alarm Set: Manual Unexpected SHTL
11501
MANUAL-UNEXPECTEDSHTL-CLEAR
Alarm clear: Manual Unexpected SHTL
11510
MANUAL-WIREFEEDERROR-SET
Alarm Set: Manual Wirefeed Error
11511
MANUAL-WIREFEEDERROR-CLEAR
Alarm clear: Manual Wirefeed Error
11520
MANUAL-EFO-INVALIDDATA-SET
Alarm Set: Manual EFO Invalid Data
11521
MANUAL-EFO-INVALIDDATA-CLEAR
Alarm clear: Manual EFO Invalid Data
11530
EFO-CLEAN-SET
Alarm Set: EFO Clean
11531
EFO-CLEAN-CLEAR
Alarm clear: EFO Clean
11540
MANUAL-UNEXPECTEDLGTL-SET
Alarm Set: Manual Unexcepted LGTL
11541
MANUAL-UNEXPECTEDLGTL-CLEAR
Alarm clear: Manual Unexcepted LGTL
11550
CAP-UNCLOG-SET
Alarm Set: Cap UNCLOG
11551
CAP-UNCLOG-CLEAR
Alarm clear: Cap UNCLOG
11560
EH_AUTO_RECV_REPLAC
E_BOFF_PLATE-SET
Alarm Set: EH Auto Recive Replace BOFF Plate
11561
EH_AUTO_RECV_REPLAC
E_BOFF_PLATE-CLEAR
Alarm clear: EH Auto Recive Replace BOFF Plate
11570
AUTO-USG-LOCK-DRIFTSET
Alarm Set: Auto USG Lock Drift
(U2)
Page - 211 - of 324
Jan 28, 2021 Rev 4.2
Kulicke & Soffa™
SECS/GEM Interface for K&S Ball Bonders
Bonder software version x-xx-x-473-series
IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Collection Events
CEID
Name
Description
11571
AUTO-USG-LOCK-DRIFTCLEAR
Alarm clear: Auto USG Lock Drift
11580
AUTO-EMS-LOW-SET
Alarm Set: Auto EMS Low
11581
AUTO-EMS-LOW-CLEAR
Alarm clear: Auto EMS Low
11590
AUTO-ALIGN-FATAL-SET
Alarm Set: Auto Align Fatal
11591
AUTO-ALIGN-FATALCLEAR
Alarm clear: Auto Align Fatal
11600
AUTO-ALIGN-MOT-FAILSET
Alarm Set: Auto Align Mot Fail
11601
AUTO-ALIGN-MOT-FAILCLEAR
Alarm clear: Auto Align Mot Fail
11610
AUTO-ALIGN-PRS-FAILSET
Alarm Set: Auto Align PRS Fail
11611
AUTO-ALIGN-PRS-FAILCLEAR
Alarm clear: Auto Align PRS Fail
11620
AUTO-ALIGN-VLL-FAILSET
Alarm Set: Auto Align VLL Fail
11621
AUTO-ALIGN-VLL-FAILCLEAR
Alarm clear: Auto Align VLL Fail
11630
AUTO-UPDATE-AWAITTIMEOUT-SET
Alarm Set: Auto Update Await Time Out
11631
AUTO-UPDATE-AWAITTIMEOUT-CLEAR
Alarm clear: Auto Update Await Time Out
11640
AUTO-BAD-START-SET
Alarm Set: Auto Bad Start
11641
AUTO-BAD-START-CLEAR
Alarm clear: Auto Bad Start
11650
AUTO-REJECTEYESKIPPARMS-EXCEEDEDSET
Alarm Set: Auto Reject Eye Skip Parameters Exceeded
11651
AUTO-REJECTEYESKIPPARMS-EXCEEDEDCLEAR
Alarm clear: Auto Reject Eye Skip Parameters Exceeded
11660
AUTO-ZPROBESKIPPARMS-EXCEEDEDSET
Alarm Set: Auto ZPROBE Skip Parameters Exceeded
11661
AUTO-ZPROBESKIPPARMS-EXCEEDEDCLEAR
Alarm clear: Auto ZPROBE Skip Parameters Exceeded
11670
AUTO-LARGE-DRIFTERROR-SET
Alarm Set: Auto Large Drift Error
(U2)
Page - 212 - of 324
Jan 28, 2021 Rev 4.2
Kulicke & Soffa™
SECS/GEM Interface for K&S Ball Bonders
Bonder software version x-xx-x-473-series
IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Collection Events
CEID
Name
Description
11671
AUTO-LARGE-DRIFTERROR-CLEAR
Alarm clear: Auto Large Drift Error
11680
FAILED-CAPILLARY-FINDSET
Alarm Set: Failed Capillary Find
11681
FAILED-CAPILLARY-FINDCLEAR
Alarm clear: Failed Capillary Find
11690
MLO-EXCESS-CHG-STOPSET
Alarm Set: MLO Excess CHG Stop
11691
MLO-EXCESS-CHG-STOPCLEAR
Alarm clear: MLO Excess CHG Stop
11700
BOFF-AREA-FULL-SET
Alarm Set: BOFF Area Full
11701
BOFF-AREA-FULL-CLEAR
Alarm clear: BOFF Area Full
11710
AUTO-NEARING-TOOLUSAGE-LIMIT-SET
Alarm Set: Auto Nearing Tool Usage Limit
11711
AUTO-NEARING-TOOLUSAGE-LIMIT-CLEAR
Alarm Set: Auto Nearing Tool Usage Limit
11720
AUTO-BONDHEAD-TABLEVIOLATION-NOWAIT-SET
Alarm Set: Auto Bondhead Table Violation No Wait
11721
AUTO-BONDHEAD-TABLEVIOLATION-NOWAITCLEAR
Alarm clear: Auto Bondhead Table Violation No Wait
11730
AUTO-CONF-BPC-ERRSET
Alarm Set: Auto Configure BPC Error
11731
AUTO-CONF-BPC-ERRCLEAR
Alarm clear: Auto Configure BPC Error
11740
AUTO-BITS-CFG-XMATCHSWDC-HWAC-SET
Alarm Set: Auto BITS Configure XMatch SWDCHWAC
11741
AUTO-BITS-CFG-XMATCHSWDC-HWAC-CLEAR
Alarm clear: Auto BITS Configure XMatch SWDCHWAC
11750
AUTO-BITS-CFG-XMATCHSWAC-HWDC-SET
Alarm Set: Auto BITS Configure XMatch SWACHWDC
11751
AUTO-BITS-CFG-XMATCHSWAC-HWDC-CLEAR
Alarm clear: Auto BITS Configure XMatch SWACHWDC
11760
AUTO-PRE-BOND-CHECKSET
Alarm Set: Auto PRE Bond Check
11761
AUTO-PRE-BOND-CHECKCLEAR
Alarm clear: Auto PRE Bond Check
11770
MC_IDLE_TOO_LONG-SET
Alarm Set: MC Idle Too Long
11771
MC_IDLE_TOO_LONGCLEAR
Alarm clear: MC Idle Too Long
(U2)
Page - 213 - of 324
Jan 28, 2021 Rev 4.2
Kulicke & Soffa™
SECS/GEM Interface for K&S Ball Bonders
Bonder software version x-xx-x-473-series
IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Collection Events
CEID
Name
Description
11780
AUTO-WIRE-USAGETHRESHOLD-EXCEEDEDSET
Alarm Set: Auto Wire Usage Threshold Exceeded
11781
AUTO-WIRE-USAGETHRESHOLD-EXCEEDEDCLEAR
Alarm clear: Auto Wire Usage Threshold Exceeded
11790
AUTO-TOOL-USAGE-LIMITEXCEEDED-NOWAIT-SET
Alarm Set: Auto Tool Usage Limit Exceeded No Wait
11791
AUTO-TOOL-USAGE-LIMITEXCEEDED-NOWAITCLEAR
Alarm clear: Auto Tool Usage Limit Exceeded No Wait
11800
AUTO-MHS-CLAMP-OPENSET
Alarm Set: Auto MHS Clamp Open
11801
AUTO-MHS-CLAMP-OPENCLEAR
Alarm clear: Auto MHS Clamp Open
11810
ZTC-AD-RANGE-ERRORSET
Alarm Set: ZTC AD Range Error
11811
ZTC-AD-RANGE-ERRORCLEAR
Alarm clear:ZTC AD Range Error
11820
AUTO-TEMP-OUT-OFRANGE-OPTICS-SET
Alarm Set: Auto Temp Out Of Range Optics
11821
AUTO-TEMP-OUT-OFRANGE-OPTICS-CLEAR
Alarm clear: Auto Temp Out Of Range Optics
11830
ZPROTECT-HI-ALARM-SET
Alarm Set: ZPROTECT HI Alarm
11831
ZPROTECT-HI-ALARMCLEAR
Alarm clear: ZPROTECT HI Alarm
11840
ZPROTECT-OPENSENSOR-SET
Alarm Set: ZPROTECT Open Sensor
11841
ZPROTECT-OPENSENSOR-CLEAR
Alarm clear: ZPROTECT Open Sensor
11850
AUTO-ALIGN-PAD-FAILSET
Alarm Set: Auto Align Pad Fail
11851
AUTO-ALIGN-PAD-FAILCLEAR
Alarm clear: Auto Align Pad Fail
11860
AUTO-TEMP-CTRL-COMMFAIL-SET
Alarm Set: Auto Temp CTRL COMM Fail
11861
AUTO-TEMP-CTRL-COMMFAIL-CLEAR
Alarm clear: Auto Temp CTRL COMM Fail
11870
OPERATOR-ERROR-SET
Alarm Set: Operator Error
11871
OPERATOR-ERRORCLEAR
Alarm clear: Operator Error
(U2)
Page - 214 - of 324
Jan 28, 2021 Rev 4.2
Kulicke & Soffa™
SECS/GEM Interface for K&S Ball Bonders
Bonder software version x-xx-x-473-series
IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Collection Events
CEID
Name
Description
11880
AUTO-MATROX-E-DRIVEFULL-SET
Alarm Set: Auto Matrox E Drive Full
11881
AUTO-MATROX-E-DRIVEFULL-CLEAR
Alarm clear: Auto Matrox E Drive Full
11890
AUTO-EFO-LIMITEXCEEDED-SET
Alarm Set: Auto EFO Limit Exceeded
11891
AUTO-EFO-LIMITEXCEEDED-CLEAR
Alarm clear: Auto EFO Limit Exceeded
11900
AUTO-EFO-START-CLEANSET
Alarm Set: Auto EFO Start Clean
11901
AUTO-EFO-START-CLEANCLEAR
Alarm clear: Auto EFO Start Clean
11910
AUTO_EFOPM_LIMIT_EXC
EEDED-SET
Alarm Set: Auto EFOPM Limit Exceeded
11911
AUTO_EFOPM_LIMIT_EXC
EEDED-CLEAR
Alarm clear: Auto EFOPM Limit Exceeded
11920
TEST-ERROR-SET
Alarm Set: Test Error
11921
TEST-ERROR-CLEAR
Alarm clear: Test Error
11930
MHS_UNDEFINED_CMDSET
Alarm Set: MHS Undefined CMD
11931
MHS_UNDEFINED_CMDCLEAR
Alarm clear: MHS Undefined CMD
11940
MHS_DISABLED_ACTIVE_
CMD-SET
Alarm Set: MHS Disabled Active Command
11941
MHS_DISABLED_ACTIVE_
CMD-CLEAR
Alarm clear: MHS Disabled Active Command
11950
MHS_UNAVAILABLE_CMD
_RESOURCES-SET
Alarm Set: MHS Unavailable Command Resources
11951
MHS_UNAVAILABLE_CMD
_RESOURCES-CLEAR
Alarm clear: MHS Unavailable Command Resources
11960
MHS_LOGIC_ERROR-SET
Alarm Set: MHS Logic Error
11961
MHS_LOGIC_ERRORCLEAR
Alarm clear: MHS Logic Error
11970
MHS_ALREADY_ACTIVE_C
MD-SET
Alarm Set: MHS Already Active Command
11971
MHS_ALREADY_ACTIVE_C
MD-CLEAR
Alarm clear: MHS Already Active Command
11980
MHS_MSG_QUEUE_OVER
FLOW-SET
Alarm Set: MHS MSG Queue Overflow
(U2)
Page - 215 - of 324
Jan 28, 2021 Rev 4.2
Kulicke & Soffa™
SECS/GEM Interface for K&S Ball Bonders
Bonder software version x-xx-x-473-series
IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Collection Events
CEID
Name
Description
11981
MHS_MSG_QUEUE_OVER
FLOW-CLEAR
Alarm clear: MHS MSG Queue Overflow
11990
MHS_DYNAMIC_LOAD_ER
ROR-SET
Alarm Set: MHS Dynamic Load Error
11991
MHS_DYNAMIC_LOAD_ER
ROR-CLEAR
Alarm clear: MHS Dynamic Load Error
12000
MHS_CONFIRM_CMD_RES
OURCES-SET
Alarm Set: MHS Confirm CMD Resources
12001
MHS_CONFIRM_CMD_RES
OURCES-CLEAR
Alarm clear: MHS Confirm CMD Resources
12010
MHS_LOGIC_ERROR_NO_
BLOCK-SET
Alarm Set: MHS Logic Error No Block
12011
MHS_LOGIC_ERROR_NO_
BLOCK-CLEAR
Alarm clear: MHS Logic Error No Block
12020
PUL_CARRIER_ALREADY_
PRESENT-SET
Alarm Set: Pul Carrier Already Present
12021
PUL_CARRIER_ALREADY_
PRESENT-CLEAR
Alarm clear: Pul Carrier Already Present
12030
MH_LOGIC_ERROR-SET
Alarm Set: MH Logic Error
12031
MH_LOGIC_ERRORCLEAR
Alarm clear: MH Logic Error
12040
MH_SETUP_ERROR-SET
Alarm Set: MH Setup Error
12041
MH_SETUP_ERRORCLEAR
Alarm clear: MH Setup Error
12050
MH_CREATE_ERROR-SET
Alarm Set: MH Create Error
12051
MH_CREATE_ERRORCLEAR
Alarm clear: MH Create Error
12060
MH_SEND_ERROR-SET
Alarm Set: MH Send Error
12061
MH_SEND_ERROR-CLEAR
Alarm clear: MH Send Error
12070
MH_RX_ERROR-SET
Alarm Set: MH RX Error
12071
MH_RX_ERROR-CLEAR
Alarm clear: MH RX Error
12080
MH_CHUTE_EMPTY-SET
Alarm Set: MH Chute Empty
12081
MH_CHUTE_EMPTYCLEAR
Alarm clear: MH Chute Empty
12090
MH_CHUTE_EMPTY_OSET
Alarm Set: MH Chute Empty O
12091
MH_CHUTE_EMPTY_OCLEAR
Alarm clear: MH Chute Empty O
(U2)
Page - 216 - of 324
Jan 28, 2021 Rev 4.2
Kulicke & Soffa™
SECS/GEM Interface for K&S Ball Bonders
Bonder software version x-xx-x-473-series
IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Collection Events
CEID
Name
Description
12100
MH_BAD_GRIPPER_SIZESET
Alarm Set: MH Bad Gripper Size
12101
MH_BAD_GRIPPER_SIZECLEAR
Alarm clear: MH Bad Gripper Size
12110
MH_BAD_GRIPPER_SIZE_
O-SET
Alarm Set: MH Bad Gripper Size O
12111
MH_BAD_GRIPPER_SIZE_
O-CLEAR
Alarm clear: MH Bad Gripper Size O
12120
MH_BAD_GRIPPER_CHAN
GE_O-SET
Alarm Set: MH Bad Gripper Change O
12121
MH_BAD_GRIPPER_CHAN
GE_O-CLEAR
Alarm clear: MH Bad Gripper Change O
12130
MH_TRAY_DETECT_SENS
OR_FAILURE_O-SET
Alarm Set: MH Tray Detect Sensor Failure O
12131
MH_TRAY_DETECT_SENS
OR_FAILURE_O-CLEAR
Alarm clear: MH Tray Detect Sensor Failure O
12140
MH_MAG_IFR-SET
Alarm Set: MH Mag IFR
12141
MH_MAG_IFR-CLEAR
Alarm clear: MH Mag IFR
12150
MH_MAG_IFR_O-SET
Alarm Set: MH Mag IFR O
12151
MH_MAG_IFR_O-CLEAR
Alarm clear: MH Mag IFR O
12160
MH_PUSHER_NOT_RETRA
CT-SET
Alarm Set: MH Pusher Not Retract
12161
MH_PUSHER_NOT_RETRA
CT-CLEAR
Alarm clear: MH Pusher Not Retract
12170
MH_PUSHER_NOT_RETRA
CT_0-SET
Alarm Set: MH Pusher Not Retract O
12171
MH_PUSHER_NOT_RETRA
CT_0-CLEAR
Alarm clear: MH Pusher Not Retract O
12180
MH_PUSHER_NOT_OUTSET
Alarm Set: MH Pusher Not Out
12181
MH_PUSHER_NOT_OUTCLEAR
Alarm clear: MH Pusher Not Out
12190
MH_PUSHER_NOT_OUT_0
-SET
Alarm Set: MH Pusher Not Out O
12191
MH_PUSHER_NOT_OUT_0
-CLEAR
Alarm clear: MH Pusher Not Out O
12200
MH_MAG_IN_LOAD_NEWSET
Alarm Set: MH Mag IN Load New
12201
MH_MAG_IN_LOAD_NEWCLEAR
Alarm clear: MH Mag IN Load New
(U2)
Page - 217 - of 324
Jan 28, 2021 Rev 4.2
Kulicke & Soffa™
SECS/GEM Interface for K&S Ball Bonders
Bonder software version x-xx-x-473-series
IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Collection Events
CEID
Name
Description
12210
MH_MAG_OUT_LOAD_NE
W-SET
Alarm Set: MH Mag Out Load New
12211
MH_MAG_OUT_LOAD_NE
W-CLEAR
Alarm clear: MH Mag Out Load New
12220
MH_STANDBY_MAG_NOT_
READY-SET
Alarm Set: MH Standby Mag Not Ready
12221
MH_STANDBY_MAG_NOT_
READY-CLEAR
Alarm clear: MH Standby Mag Not Ready
12230
MH_STANDBY_MAG_NOT_
READY_O-SET
Alarm Set: MH Standby May Not Ready O
12231
MH_STANDBY_MAG_NOT_
READY_O-CLEAR
Alarm clear: MH Standby May Not Ready O
12240
MH_TRAY_FULL_DETECTSET
Alarm Set: MH Tray Full Detect
12241
MH_TRAY_FULL_DETECTCLEAR
Alarm clear: MH Tray Full Detect
12250
MH_TRAY_FULL_DETECT_
O-SET
Alarm Set: MH Tray Full Detect O
12251
MH_TRAY_FULL_DETECT_
O-CLEAR
Alarm clear: MH Tray Full Detect O
12260
MH_INVALID_SENSORSET
Alarm Set: MH Invalid Sensor
12261
MH_INVALID_SENSORCLEAR
Alarm clear: MH Invalid Sensor
12270
MH_TEACH_OPERATION_
WORKED-SET
Alarm Set: MH Teach Operation Worked
12271
MH_TEACH_OPERATION_
WORKED-CLEAR
Alarm clear: MH Teach Operation Worked
12280
WHL_UNDEFINED_CRR_L
OCK_STS-SET
Alarm Set: WHL Undefined CRR Lock STS
12281
WHL_UNDEFINED_CRR_L
OCK_STS-CLEAR
Alarm clear: WHL Undefined CRR Lock STS
12290
WHL_UNDEFINED_INDEX_
TYPE-SET
Alarm Set: WHL Undefined Index Type
12291
WHL_UNDEFINED_INDEX_
TYPE-CLEAR
Alarm clear: WHL Undefined Index Type
12300
WHL_UNDEFINED_INDEX_
STS-SET
Alarm Set: WHL Undefined Index STS
12301
WHL_UNDEFINED_INDEX_
STS-CLEAR
Alarm clear: WHL Undefined Index STS
(U2)
Page - 218 - of 324
Jan 28, 2021 Rev 4.2
Kulicke & Soffa™
SECS/GEM Interface for K&S Ball Bonders
Bonder software version x-xx-x-473-series
IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Collection Events
CEID
Name
Description
12310
WHL_UNDEFINED_CORR_
STS-SET
Alarm Set: WHL Undefined CORR STS
12311
WHL_UNDEFINED_CORR_
STS-CLEAR
Alarm clear: WHL Undefined CORR STS
12320
WHL_UNDEFINED_INDEX_
CYCLE-SET
Alarm Set: WHL Undefined Index Cycle
12321
WHL_UNDEFINED_INDEX_
CYCLE-CLEAR
Alarm clear: WHL Undefined Index Cycle
12330
WHL_UNDEFINED_INDEXE
R_STATE-SET
Alarm Set: WHL Undefined Indexer State
12331
WHL_UNDEFINED_INDEXE
R_STATE-CLEAR
Alarm clear: WHL Undefined Indexer State
12340
WHL_UNDEFINED_PULLE
R_STATE-SET
Alarm Set: WHL Undefined Puller State
12341
WHL_UNDEFINED_PULLE
R_STATE-CLEAR
Alarm clear: WHL Undefined Puller State
12350
WHL_CANNOT_CREATE_S
EMAPHORE-SET
Alarm Set: WHL Cannot Create Semaphore
12351
WHL_CANNOT_CREATE_S
EMAPHORE-CLEAR
Alarm clear: WHL Cannot Create Semaphore
12360
WHL_CANNOT_OPEN_CH
ANNEL-SET
Alarm Set: WHL Cannot Open Channel
12361
WHL_CANNOT_OPEN_CH
ANNEL-CLEAR
Alarm clear: WHL Cannot Open Channel
12370
WHL_UNDEFINED_PULL_T
YPE-SET
Alarm Set: WHL Undefined Pull Type
12371
WHL_UNDEFINED_PULL_T
YPE-CLEAR
Alarm clear: WHL Undefined Pull Type
12380
WHL_WANTS_BONDHEAD
_MOVED-SET
Alarm Set: WHL Wants Bondhead Moved
12381
WHL_WANTS_BONDHEAD
_MOVED-CLEAR
Alarm clear: WHL Wants Bondhead Moved
12390
WHL_WANTS_BONDHEAD
_POSITIONED-SET
Alarm Set: WHL Wants Bondhead Positioned
12391
WHL_WANTS_BONDHEAD
_POSITIONED-CLEAR
Alarm clear: WHL Wants Bondhead Positioned
12400
MHS_CMD_TBL_SIZE_ERR
OR-SET
Alarm Set: MHS CMD TBL Size Error
12401
MHS_CMD_TBL_SIZE_ERR
OR-CLEAR
Alarm clear: MHS CMD TBL Size Error
(U2)
Page - 219 - of 324
Jan 28, 2021 Rev 4.2
Kulicke & Soffa™
SECS/GEM Interface for K&S Ball Bonders
Bonder software version x-xx-x-473-series
IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Collection Events
CEID
Name
Description
12410
MHS_JDC_CMD_TIMEOUT
-SET
Alarm Set: MHS JDC CMD Time Out
12411
MHS_JDC_CMD_TIMEOUT
-CLEAR
Alarm clear: MHS JDC CMD Time Out
12420
PUSHER_KIT_JAM-SET
Alarm Set: Pusher Kit Jam
12421
PUSHER_KIT_JAM-CLEAR
Alarm clear: Pusher Kit Jam
12430
PUSHER_KIT_SENSOR_FA
ILURE-SET
Alarm Set: Pusher Kit Sensor Failure
12431
PUSHER_KIT_SENSOR_FA
ILURE-CLEAR
Alarm clear: Pusher Kit Sensor Failure
12440
SENSOR_MON_UNSAFESET
Alarm Set: Sensor MON Unsafe
12441
SENSOR_MON_UNSAFECLEAR
Alarm clear: Sensor MON Unsafe
12450
SENSOR_MON_UNSAFE_
WHEN_BONDING-SET
Alarm Set: Sensor MON Unsafe When Bonding
12451
SENSOR_MON_UNSAFE_
WHEN_BONDING-CLEAR
Alarm clear: Sensor MON Unsafe When Bonding
12460
MH_FAILED_GRIP_MAG_O
-SET
Alarm Set: MH Failed Grip Mag O
12461
MH_FAILED_GRIP_MAG_O
-CLEAR
Alarm clear: MH Failed Grip Mag O
12470
PULLER_GRIPPER_SENS
OR_FAILURE-SET
Alarm Set: Puller Gripper Sensor Failure
12471
PULLER_GRIPPER_SENS
OR_FAILURE-CLEAR
Alarm clear: Puller Gripper Sensor Failure
12480
RAILS_TARGET_POS_CLI
PPED-SET
Alarm Set: Rails Target POS Clipped
12481
RAILS_TARGET_POS_CLI
PPED-CLEAR
Alarm clear: Rails Target POS Clipped
12490
MHS_NEED_CAL_FOR_CI
WIDTHCHK_NO_DONESET
Alarm Set: MHS Need Cal For CIWIDTHCHK No Done
12491
MHS_NEED_CAL_FOR_CI
WIDTHCHK_NO_DONECLEAR
Alarm clear: MHS Need Cal For CIWIDTHCHK No Done
12500
EH_CAPILLARY_DETECTI
ON_ERROR-SET
Alarm Set: EH Capillary Detection Error
12501
EH_CAPILLARY_DETECTI
ON_ERROR-CLEAR
Alarm clear: EH Capillary Detection Error
(U2)
Page - 220 - of 324
Jan 28, 2021 Rev 4.2
Kulicke & Soffa™
SECS/GEM Interface for K&S Ball Bonders
Bonder software version x-xx-x-473-series
IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Collection Events
CEID
Name
Description
12510
EH_FAST_PACKAGE_ALIG
N_FAIL-SET
Fast package alignment error set
12511
EH_FAST_PACKAGE_ALIG
N_FAIL-CLEAR
Fast package alignment error clear
12520
IND_LOAD_SENSOR_UNS
AFE-SET
Alarm Set: IND Load Sensor Unsafe
12521
IND_LOAD_SENSOR_UNS
AFE-CLEAR
Alarm clear: IND Load Sensor Unsafe
12530
RWH_INDEX_FAILURESET
Alarm Set: RWH Index Failure
12531
RWH_INDEX_FAILURECLEAR
Alarm clear: RWH Index Failure
12540
MHS_PARAMETER_ERRO
R-SET
Alarm Set: MHS Parameter Error
12541
MHS_PARAMETER_ERRO
R-CLEAR
Alarm clear: MHS Parameter Error
12550
RWH_IM_CMD_FAILURESET
Alarm Set: RWH IM CMD Failure
12551
RWH_IM_CMD_FAILURECLEAR
Alarm clear: RWH IM CMD Failure
12560
RWH_IV_CMD_FAILURESET
Alarm Set: RWH IV CMD Failure
12561
RWH_IV_CMD_FAILURECLEAR
Alarm clear: RWH IV CMD Failure
12570
RWH_CB_CMD_FAILURESET
Alarm Set: RWH CB CMD Failure
12571
RWH_CB_CMD_FAILURECLEAR
Alarm clear: RWH CB CMD Failure
12580
INDEX_GRP_SENSOR_FAI
LURE-SET
Alarm Set: Index GRP Sensor Failure
12581
INDEX_GRP_SENSOR_FAI
LURE-CLEAR
Alarm clear: Index GRP Sensor Failure
12590
EJECT_GRP_SENSOR_FAI
LURE-SET
Alarm Set: Eject GRP Sensor Failure
12591
EJECT_GRP_SENSOR_FAI
LURE-CLEAR
Alarm clear: Eject GRP Sensor Failure
12600
PUL_CARRIER_WRONG_O
RIENTATION-SET
Alarm Set: PUL Carrier Wrong Orientation
12601
PUL_CARRIER_WRONG_O
RIENTATION-CLEAR
Alarm clear: PUL Carrier Wrong Orientation
(U2)
Page - 221 - of 324
Jan 28, 2021 Rev 4.2
Kulicke & Soffa™
SECS/GEM Interface for K&S Ball Bonders
Bonder software version x-xx-x-473-series
IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Collection Events
CEID
Name
Description
12610
PUL_CARRIER_ORIENTATI
ON_EDGE_NOT_FOUNDSET
Alarm Set: PUL Carrier Orientation Edge Not Found
12611
PUL_CARRIER_ORIENTATI
ON_EDGE_NOT_FOUNDCLEAR
Alarm clear: PUL Carrier Orientation Edge Not Found
12620
MHS_WHL_VERIFICATION
_UNSUCCESSFUL-SET
Alarm Set: MHS WHL Verification Unsucessful
12621
MHS_WHL_VERIFICATION
_UNSUCCESSFUL-CLEAR
Alarm clear: MHS WHL Verification Unsucessful
12630
INDEX_THETA_BAR_SENS
OR_FAILURE-SET
Alarm Set: Index Theta Bar Sensor Failure
12631
INDEX_THETA_BAR_SENS
OR_FAILURE-CLEAR
Alarm clear: Index Theta Bar Sensor Failure
12640
EJECT_THETA_BAR_SENS
OR_FAILURE-SET
Alarm Set: Eject Theta Bar Sensor Failure
12641
EJECT_THETA_BAR_SENS
OR_FAILURE-CLEAR
Alarm clear: Eject Theta Bar Sensor Failure
12650
MHS_GRIP_POINT_ERRO
R-SET
Alarm Set: MHS Grip Point Error
12651
MHS_GRIP_POINT_ERRO
R-CLEAR
Alarm clear: MHS Grip Point Error
12660
MHS_GP_ERROR_INDEX_
ABORT-SET
Alarm Set: MHS GP Error Index Abort
12661
MHS_GP_ERROR_INDEX_
ABORT-CLEAR
Alarm clear: MHS GP Error Index Abort
12670
LOAD_FAILED-SET
Alarm Set: Load Failed
12671
LOAD_FAILED-CLEAR
Alarm clear: Load Failed
12680
LOAD_INFO-SET
Alarm Set: Load INFO
12681
LOAD_INFO-CLEAR
Alarm clear: Load INFO
12690
LOAD_INTERNAL_ERRORSET
Alarm Set: Load Internal Error
12691
LOAD_INTERNAL_ERRORCLEAR
Alarm clear: Load Internal Error
12700
LOADER_BUSY-SET
Alarm Set: Loader Busy
12701
LOADER_BUSY-CLEAR
Alarm clear: Loader Busy
12710
AUTO_PARAM_LOAD_FAIL
ED-SET
Alarm Set: Auto Param Load Failed
12711
AUTO_PARAM_LOAD_FAIL
ED-CLEAR
Alarm clear: Auto Param Load Failed
(U2)
Page - 222 - of 324
Jan 28, 2021 Rev 4.2
Kulicke & Soffa™
SECS/GEM Interface for K&S Ball Bonders
Bonder software version x-xx-x-473-series
IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Collection Events
CEID
Name
Description
12720
MISCT_PARAM_LOAD_FAI
LED-SET
Alarm Set: Misct Param Load Failed
12721
MISCT_PARAM_LOAD_FAI
LED-CLEAR
Alarm clear: Misct Param Load Failed
12730
LEADT_PARAM_LOAD_FAI
LED-SET
Alarm Set: Leadt Param Load Failed
12731
LEADT_PARAM_LOAD_FAI
LED-CLEAR
Alarm clear: Leadt Param Load Failed
12740
PADT_PARAM_LOAD_FAIL
ED-SET
Alarm Set: Padt Param Load Failed
12741
PADT_PARAM_LOAD_FAIL
ED-CLEAR
Alarm clear: Padt Param Load Failed
12750
INV_AUTO_PRM_DATA_PT
R-SET
Alarm Set: INV Auto PRM Data PTR
12751
INV_AUTO_PRM_DATA_PT
R-CLEAR
Alarm clear: INV Auto PRM Data PTR
12760
AUTO_PRM_RES_NOT_RE
L-SET
Alarm Set: Auto PRM RES Not REL
12761
AUTO_PRM_RES_NOT_RE
L-CLEAR
Alarm clear: Auto PRM RES Not REL
12770
AUTO_PRM_RES_NOT_AV
L-SET
Alarm Set: Auto PRM RES Not AVL
12771
AUTO_PRM_RES_NOT_AV
L-CLEAR
Alarm clear: Auto PRM RES Not AVL
12780
INV_TCH_PRM_DATA_PTR
-SET
Alarm Set: INV TCH PRM Data PTR
12781
INV_TCH_PRM_DATA_PTR
-CLEAR
Alarm clear: INV TCH PRM Data PTR
12790
MISCT_PRM_RES_NOT_R
EL-SET
Alarm Set: MISCT PRM RES Not REL
12791
MISCT_PRM_RES_NOT_R
EL-CLEAR
Alarm clear: MISCT PRM RES Not REL
12800
MISCT_PRM_RES_NOT_A
VL-SET
Alarm Set: MISCT PRM RES Not AVL
12801
MISCT_PRM_RES_NOT_A
VL-CLEAR
Alarm clear: MISCT PRM RES Not AVL
12810
LEADT_PRM_RES_NOT_R
EL-SET
Alarm Set: LeadT PRM RES Not REL
12811
LEADT_PRM_RES_NOT_R
EL-CLEAR
Alarm clear: LeadT PRM RES Not REL
(U2)
Page - 223 - of 324
Jan 28, 2021 Rev 4.2
Kulicke & Soffa™
SECS/GEM Interface for K&S Ball Bonders
Bonder software version x-xx-x-473-series
IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Collection Events
CEID
Name
Description
12820
LEADT_PRM_RES_NOT_A
VL-SET
Alarm Set: LeadT PRM RES Not AVL
12821
LEADT_PRM_RES_NOT_A
VL-CLEAR
Alarm clear: LeadT PRM RES Not AVL
12830
PADT_PRM_RES_NOT_RE
L-SET
Alarm Set: PADT PRM RES Not REL
12831
PADT_PRM_RES_NOT_RE
L-CLEAR
Alarm clear: PADT PRM RES Not REL
12840
PADT_PRM_RES_NOT_AV
L-SET
Alarm Set: PADT PRM RES Not AVL
12841
PADT_PRM_RES_NOT_AV
L-CLEAR
Alarm clear: PADT PRM RES Not AVL
12850
RESTORE_ERROR-SET
Alarm Set: Restore Error
12851
RESTORE_ERROR-CLEAR
Alarm clear: Restore Error
12860
BACKUP_ERROR-SET
Alarm Set: Backup Error
12861
BACKUP_ERROR-CLEAR
Alarm clear: Backup Error
12870
SELECT_ERROR-SET
Alarm Set: Select Error
12871
SELECT_ERROR-CLEAR
Alarm clear: Select Error
12880
MEMORY_ERROR-SET
Alarm Set: Memory Error
12881
MEMORY_ERROR-CLEAR
Alarm clear: Memory Error
12890
FILE_ERROR-SET
Alarm Set: File Error
12891
FILE_ERROR-CLEAR
Alarm clear: File Error
12900
CLEANUP_ERROR-SET
Alarm Set: Clean Up Error
12901
CLEANUP_ERROR-CLEAR
Alarm clear: Clean Up Error
12910
BACKUP_LIST_FILE_INVAL
ID-SET
Alarm Set: Backup list File Invalid
12911
BACKUP_LIST_FILE_INVAL
ID-CLEAR
Alarm clear: Backup list File Invalid
12920
PP_HEAP_ALLOC_FAILEDSET
Alarm Set: PP Heap Alloc Failed
12921
PP_HEAP_ALLOC_FAILEDCLEAR
Alarm clear: PP Heap Alloc Failed
12930
PP_HEAP_CREATE_FAILE
D-SET
Alarm Set: PP Heap Create Failed
12931
PP_HEAP_CREATE_FAILE
D-CLEAR
Alarm clear: PP Heap Create Failed
12940
PP_HEAP_SIZE_INVALIDSET
Alarm Set: PP Heap Size Invalid
(U2)
Page - 224 - of 324
Jan 28, 2021 Rev 4.2
Kulicke & Soffa™
SECS/GEM Interface for K&S Ball Bonders
Bonder software version x-xx-x-473-series
IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Collection Events
CEID
Name
Description
12941
PP_HEAP_SIZE_INVALIDCLEAR
Alarm clear: PP Heap Size Invalid
12950
MON-Y-MOTOR-OVERTEMP-SET
Alarm Set: MON Motor Over Temp
12951
MON-Y-MOTOR-OVERTEMP-CLEAR
Alarm clear: MON Motor Over Temp
12960
MON-MOTOR-WARNINGSET
Alarm Set: MON Motor Warning
12961
MON-MOTOR-WARNINGCLEAR
Alarm clear: MON Motor Warning
12970
MON-UPS-RUNNING-SET
Alarm Set: MON UPS Running
12971
MON-UPS-RUNNINGCLEAR
Alarm clear: MON UPS Running
12980
MON-SENSOR-BUSERROR-SET
Alarm Set: MON Sensor Bus Error
12981
MON-SENSOR-BUSERROR-CLEAR
Alarm clear: MON Sensor Bus Error
12990
MON-UPS-BAD-BATTERYSET
Alarm Set: MON Ups Bad Battery
12991
MON-UPS-BAD-BATTERYCLEAR
Alarm clear: MON Ups Bad Battery
13000
EH_MON_IDLE_CLAMP_O
PEN_TIMEOUT-SET
Alarm Set: EH MON Idle clamp Open Time Out
13001
EH_MON_IDLE_CLAMP_O
PEN_TIMEOUT-CLEAR
Alarm clear: EH MON Idle clamp Open Time Out
13010
EH_GRIPPER_SOLENOID_
OVER_TEMP_FAIL-SET
Alarm Set: EH Gripper Solenoid Over Temp Fail
13011
EH_GRIPPER_SOLENOID_
OVER_TEMP_FAIL-CLEAR
Alarm clear: EH Gripper Solenoid Over Temp Fail
13020
EH_STANDBY_SEND_MHS
_COMMAND-SET
Alarm Set: EH Standby Send MHS Command
13021
EH_STANDBY_SEND_MHS
_COMMAND-CLEAR
Alarm clear: EH Standby Send MHS Command
13030
EH_STANDBY_ERRORSET
Alarm Set: EH Standby Error
13031
EH_STANDBY_ERRORCLEAR
Alarm clear: EH Standby Error
13040
POWER-FAILURE-REBOOT-MACHINE-SET
Alarm Set: Power Failure Reboot Machine
(U2)
Page - 225 - of 324
Jan 28, 2021 Rev 4.2
Kulicke & Soffa™
SECS/GEM Interface for K&S Ball Bonders
Bonder software version x-xx-x-473-series
IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Collection Events
CEID
Name
Description
13041
POWER-FAILURE-REBOOT-MACHINE-CLEAR
Alarm clear: Power Failure Reboot Machine
13050
MOMENTARY-POWERFAILURE-SET
Alarm Set: Momentary Power Failure
13051
MOMENTARY-POWERFAILURE-CLEAR
Alarm clear: Momentary Power Failure
13060
POWER-LOW--REBOOTMACHINE-SET
Alarm Set: Power Low Reboot Machine
13061
POWER-LOW--REBOOTMACHINE-CLEAR
Alarm clear: Power Low Reboot Machine
13070
MOMENTARY-POWERLOW-SET
Alarm Set: Momentary Power Low
13071
MOMENTARY-POWERLOW-CLEAR
Alarm clear: Momentary Power Low
13080
POWER-OVERTEMP-REBOOT-MACHINE-SET
Alarm Set: Power Overtemp Reboot Machine
13081
POWER-OVERTEMP-REBOOT-MACHINE-CLEAR
Alarm clear: Power Overtemp Reboot Machine
13090
MOMENTARY-POWEROVERTEMP-SET
Alarm Set: Momentary Power Overtemp
13091
MOMENTARY-POWEROVERTEMP-CLEAR
Alarm clear: Momentary Power Overtemp
13100
SYSTEM-FAILURE-REBOOT-MACHINE-SET
Alarm Set: System Failure Reboot Machine
13101
SYSTEM-FAILURE-REBOOT-MACHINE-CLEAR
Alarm clear: System Failure Reboot Machine
13110
MOMENTARY-SYSTEMFAILURE-SET
Alarm Set: Momentary System Failure
13111
MOMENTARY-SYSTEMFAILURE-CLEAR
Alarm clear: Momentary System Failure
13120
Z-CONTACT_FAILURE-SET
Alarm Set: Z Contact Failure
13121
Z-CONTACT_FAILURECLEAR
Alarm clear: Z Contact Failure
13130
Z-POSITION_ERROR-SET
Alarm Set: Z Position Error
13131
Z-POSITION_ERRORCLEAR
Alarm clear: Z Position Error
13140
ZSEEK_RECOVERY_ERRO
R-SET
Alarm Set: Z Seek Recovery Error
(U2)
Page - 226 - of 324
Jan 28, 2021 Rev 4.2
Kulicke & Soffa™
SECS/GEM Interface for K&S Ball Bonders
Bonder software version x-xx-x-473-series
IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Collection Events
CEID
Name
Description
13141
ZSEEK_RECOVERY_ERRO
R-CLEAR
Alarm clear: Z Seek Recovery Error
13150
CPU2_Z_NEG_LIMIT_UPD
ATE_ERROR-SET
Alarm Set: CPU2 Z NEG Limit Update Error
13151
CPU2_Z_NEG_LIMIT_UPD
ATE_ERROR-CLEAR
Alarm clear: CPU2 Z NEG Limit Update Error
13160
X-POSITION_ERROR-SET
Alarm Set: X Position Error
13161
X-POSITION_ERRORCLEAR
Alarm clear: X Position Error
13170
Y-POSITION_ERROR-SET
Alarm Set: Y Position Error
13171
Y-POSITION_ERRORCLEAR
Alarm clear: Y Position Error
13180
EH_Z_LIMIT_FIND_ERROR
-SET
Alarm Set: EH Z Limit Find Error
13181
EH_Z_LIMIT_FIND_ERROR
-CLEAR
Alarm clear: EH Z Limit Find Error
13190
EH_BFC_MOTION_ERROR
-SET
Alarm Set: EH BFC Motion Error
13191
EH_BFC_MOTION_ERROR
-CLEAR
Alarm clear: EH BFC Motion Error
13200
EH_BFC_NON_MOTION_E
RROR-SET
Alarm Set: EH BFC NON Motion Error
13201
EH_BFC_NON_MOTION_E
RROR-CLEAR
Alarm clear: EH BFC NON Motion Error
13210
EH_ZMAP_MOTION_ERRO
R-SET
Alarm Set: EH ZMAP Motion Error
13211
EH_ZMAP_MOTION_ERRO
R-CLEAR
Alarm clear: EH ZMAP Motion Error
13220
EH_BITS_AGC_CAL_NOT_
DONE-SET
Alarm Set: EH BITS AGC CAL Not Done
13221
EH_BITS_AGC_CAL_NOT_
DONE-CLEAR
Alarm clear: EH BITS AGC CAL Not Done
13230
EH_FS_BONDOFF_VERIFY
_FAIL-SET
Alarm Set: EH FS Bondoff Verify Fail
13231
EH_FS_BONDOFF_VERIFY
_FAIL-CLEAR
Alarm clear: EH FS Bondoff Verify Fail
13240
EH_WFEED_COMPORT_O
PER_ERROR-SET
Alarm Set: EH Wfeed COMPORT Oper Error
(U2)
Page - 227 - of 324
Jan 28, 2021 Rev 4.2
Kulicke & Soffa™
SECS/GEM Interface for K&S Ball Bonders
Bonder software version x-xx-x-473-series
IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Collection Events
CEID
Name
Description
13241
EH_WFEED_COMPORT_O
PER_ERROR-CLEAR
Alarm clear: EH Wfeed COMPORT Oper Error
13250
EH_WFEED_COMMUNICA
TION_ERROR-SET
Alarm Set: EH Wfeed Communication Error
13251
EH_WFEED_COMMUNICA
TION_ERROR-CLEAR
Alarm clear: EH Wfeed Communication Error
13260
TEMPERATURE_COMMUN
ICATION_ERROR-SET
Alarm Set: Temperature Communication Error
13261
TEMPERATURE_COMMUN
ICATION_ERROR-CLEAR
Alarm clear: Temperature Communication Error
13270
EH_TEMP_INVALID_PARA
MS-SET
Alarm Set: EH Temp Invalid Params
13271
EH_TEMP_INVALID_PARA
MS-CLEAR
Alarm clear: EH Temp Invalid Params
13280
EH_TEMP_RESOURCE_AC
QUIRE_ERROR-SET
Alarm Set: EH Temp Resource Acquire Error
13281
EH_TEMP_RESOURCE_AC
QUIRE_ERROR-CLEAR
Alarm clear: EH Temp Resource Acquire Error
13290
EH_TEMP_INVALID_SYS_
R_SELECTOR-SET
Alarm Set: EH Temp Invalid SYS R Selector
13291
EH_TEMP_INVALID_SYS_
R_SELECTOR-CLEAR
Alarm clear: EH Temp Invalid SYS R Selector
13300
EH_TEMP_INVALID_SYS_
G_SELECTOR-SET
Alarm Set: EH Temp Invalid SYS G Selector
13301
EH_TEMP_INVALID_SYS_
G_SELECTOR-CLEAR
Alarm clear: EH Temp Invalid SYS G Selector
13310
EH_TEMP_INVALID_ZONE
_R_SELECTOR-SET
Alarm Set: EH Temp Invalid Zone R Selector
13311
EH_TEMP_INVALID_ZONE
_R_SELECTOR-CLEAR
Alarm clear: EH Temp Invalid Zone R Selector
13320
EH_TEMP_INVALID_ZONE
_EM_SELECTOR-SET
Alarm Set: EH Temp Invalid Zone EM Selector
13321
EH_TEMP_INVALID_ZONE
_EM_SELECTOR-CLEAR
Alarm clear: EH Temp Invalid Zone EM Selector
13330
EH_TEMP_PID_RESET_VA
LUE_ERROR-SET
Alarm Set: EH Temp Pid Reset Value Error
13331
EH_TEMP_PID_RESET_VA
LUE_ERROR-CLEAR
Alarm clear: EH Temp Pid Reset Value Error
13340
EH_TEMP_OFFSET_VALU
E_ERROR-SET
Alarm Set: EH Temp Offset Value Error
(U2)
Page - 228 - of 324
Jan 28, 2021 Rev 4.2
Kulicke & Soffa™
SECS/GEM Interface for K&S Ball Bonders
Bonder software version x-xx-x-473-series
IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Collection Events
CEID
Name
Description
13341
EH_TEMP_OFFSET_VALU
E_ERROR-CLEAR
Alarm clear: EH Temp Offset Value Error
13350
EH_TEMP_ZONE_EM_PAR
AM_ERROR-SET
Alarm Set: EH Temp Zone EM Param Error
13351
EH_TEMP_ZONE_EM_PAR
AM_ERROR-CLEAR
Alarm clear: EH Temp Zone EM Param Error
13360
EH_TEMP_SERIAL_WRITE
_ERROR-SET
Alarm Set: EH Temp Serial Write Error
13361
EH_TEMP_SERIAL_WRITE
_ERROR-CLEAR
Alarm clear: EH Temp Serial Write Error
13370
EH_TEMP_SERIAL_READ_
ERROR-SET
Alarm Set: EH Temp Serial Read Error
13371
EH_TEMP_SERIAL_READ_
ERROR-CLEAR
Alarm clear: EH Temp Serial Read Error
13380
EH_TEMP_ERROR_MSG_
REPLY-SET
Alarm Set: EH Temp Error MSG Reply
13381
EH_TEMP_ERROR_MSG_
REPLY-CLEAR
Alarm clear: EH Temp Error MSG Reply
13390
EH_TEMP_READ_NOT_RE
ADY-SET
Alarm Set: EH Temp Read Not Ready
13391
EH_TEMP_READ_NOT_RE
ADY-CLEAR
Alarm clear: EH Temp Read Not Ready
13400
EH_TEMP_WRITE_NOT_R
EADY-SET
Alarm Set: EH Temp Write Not Ready
13401
EH_TEMP_WRITE_NOT_R
EADY-CLEAR
Alarm clear: EH Temp Write Not Ready
13410
EH_TEMP_IO_SELECT_ER
ROR-SET
Alarm Set: EH Temp IO Select Error
13411
EH_TEMP_IO_SELECT_ER
ROR-CLEAR
Alarm clear: EH Temp IO Select Error
13420
EH_TEMP_WRITE_PROTE
CTED_PARM-SET
Alarm Set: EH Temp Write Protected Parm
13421
EH_TEMP_WRITE_PROTE
CTED_PARM-CLEAR
Alarm clear: EH Temp Write Protected Parm
13430
EH_TEMP_UNKNOWN_ER
ROR-SET
Alarm Set: EH Temp Unknown Error
13431
EH_TEMP_UNKNOWN_ER
ROR-CLEAR
Alarm clear: EH Temp Unknown Error
13440
EH_TEMP_CHANGERATE_
ERROR-SET
Alarm Set: EH Temp Changerate Error
(U2)
Page - 229 - of 324
Jan 28, 2021 Rev 4.2
Kulicke & Soffa™
SECS/GEM Interface for K&S Ball Bonders
Bonder software version x-xx-x-473-series
IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Collection Events
CEID
Name
Description
13441
EH_TEMP_CHANGERATE_
ERROR-CLEAR
Alarm clear: EH Temp Changerate Error
13450
EH_IDIAG_SYNCH_ERROR
-SET
Alarm Set: EH Idiag SYNCH Error
13451
EH_IDIAG_SYNCH_ERROR
-CLEAR
Alarm clear: EH Idiag SYNCH Error
13460
EH_IDIAG_ASYNCH_ERRO
R-SET
Alarm Set: EH Idiag ASYNCH Error
13461
EH_IDIAG_ASYNCH_ERRO
R-CLEAR
Alarm clear: EH Idiag ASYNCH Error
13470
EH_IDIAG_TEMP_ZONE_F
AULT-SET
Alarm Set: EH Idiag Temp Zone Fault
13471
EH_IDIAG_TEMP_ZONE_F
AULT-CLEAR
Alarm clear: EH Idiag Temp Zone Fault
13480
EH_IDIAG_BITS_MODE_H
W_SW_MISMATCH-SET
Alarm Set: EH Idiag BITS Mode HW SW MISMATCH
13481
EH_IDIAG_BITS_MODE_H
W_SW_MISMATCH-CLEAR
Alarm clear: EH Idiag BITS Mode HW SW MISMATCH
13490
EH_IDIAG_BITS_CROSSLO
AD_ERROR-SET
Alarm Set: EH Idiag BITS Crossload Error
13491
EH_IDIAG_BITS_CROSSLO
AD_ERROR-CLEAR
Alarm clear: EH Idiag BITS Crossload Error
13500
EH_BITS_FULL_AGC_FAIL
ED-SET
Alarm Set: EH BITS FULL AGC Failed
13501
EH_BITS_FULL_AGC_FAIL
ED-CLEAR
Alarm clear: EH BITS FULL AGC Failed
13510
EH_BITS_WF_DUMP_FAIL
ED-SET
Alarm Set: EH BITS WF Dump Failed
13511
EH_BITS_WF_DUMP_FAIL
ED-CLEAR
Alarm clear: EH BITS WF Dump Failed
13520
EH_BITS_WF_LOG_FAILE
D-SET
Alarm Set: EH BITS WF LOG Failed
13521
EH_BITS_WF_LOG_FAILE
D-CLEAR
Alarm clear: EH BITS WF LOG Failed
13530
EH_IDIAG_EEPROM_ERR
OR-SET
Alarm Set: EH BITS EEPROM Error
13531
EH_IDIAG_EEPROM_ERR
OR-CLEAR
Alarm clear: EH BITS EEPROM Error
13540
EH_IDIAG_INVALID_TABLE
_CONFIG-SET
Alarm Set: EH Idiag Invalid Table Configure
(U2)
Page - 230 - of 324
Jan 28, 2021 Rev 4.2
Kulicke & Soffa™
SECS/GEM Interface for K&S Ball Bonders
Bonder software version x-xx-x-473-series
IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Collection Events
CEID
Name
Description
13541
EH_IDIAG_INVALID_TABLE
_CONFIG-CLEAR
Alarm clear: EH Idiag Invalid Table Configure
13550
TAR_ERROR-SET
Alarm Set: Tar Error
13551
TAR_ERROR-CLEAR
Alarm clear: Tar Error
13560
TAR_WARNING-SET
Alarm Set: Tar Warning
13561
TAR_WARNING-CLEAR
Alarm clear: Tar Warning
13570
FLOPPY_WRITE_PROTEC
TED-SET
Alarm Set: Floppy Write Protected
13571
FLOPPY_WRITE_PROTEC
TED-CLEAR
Alarm clear: Floppy Write Protected
13580
FLOPPY_INSERT_ERRORSET
Alarm Set: Floppy Insert Error
13581
FLOPPY_INSERT_ERRORCLEAR
Alarm clear: Floppy Insert Error
13590
DEVICE_READY_ERRORSET
Alarm Set: Device Ready Error
13591
DEVICE_READY_ERRORCLEAR
Alarm clear: Device Ready Error
13600
DISK_FULL_ERROR-SET
Alarm Set: Disk Full Error
13601
DISK_FULL_ERRORCLEAR
Alarm clear: Disk Full Error
13610
INSERT_NEXT_DISK-SET
Alarm Set: Insert Next Disk
13611
INSERT_NEXT_DISKCLEAR
Alarm clear: Insert Next Disk
13620
CALIBRATION_DATA_ERR
OR-SET
Alarm Set: Calibration Data Error
13621
CALIBRATION_DATA_ERR
OR-CLEAR
Alarm clear: Calibration Data Error
13630
INVALID-SET
Alarm Set: Invalid
13631
INVALID-CLEAR
Alarm clear:Invalid
13640
MISSING_MARKERS-SET
Alarm Set: Missing Markers
13641
MISSING_MARKERSCLEAR
Alarm clear: Missing Markers
13650
CRC_OR_TIME_INVALIDSET
Alarm Set: CRC Or Time Invalid
13651
CRC_OR_TIME_INVALIDCLEAR
Alarm clear: CRC Or Time Invalid
(U2)
Page - 231 - of 324
Jan 28, 2021 Rev 4.2
Kulicke & Soffa™
SECS/GEM Interface for K&S Ball Bonders
Bonder software version x-xx-x-473-series
IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Collection Events
CEID
Name
Description
13660
CRC_STRING_LENGTH_IN
VALID-SET
Alarm Set: CRC String Length Invalid
13661
CRC_STRING_LENGTH_IN
VALID-CLEAR
Alarm clear: CRC String Length Invalid
13670
TIME_STRING_LENGTH_IN
VALID-SET
Alarm Set: Time String Length Invalid
13671
TIME_STRING_LENGTH_IN
VALID-CLEAR
Alarm clear: Time String Length Invalid
13680
EH_BONDER_CONFIG_ER
ROR-SET
Alarm Set: EH Bonder Configure Error
13681
EH_BONDER_CONFIG_ER
ROR-CLEAR
Alarm clear: EH Bonder Configure Error
13690
EH_FAINT6_CPU_SPURIO
US_INT-SET
Alarm Set: EH Faint6 CPU Spurious INT
13691
EH_FAINT6_CPU_SPURIO
US_INT-CLEAR
Alarm clear: EH Faint6 CPU Spurious INT
13700
EH_PCI_BRIDGE_FAILURE
-SET
Alarm Set: EH PCI Bridge Failure
13701
EH_PCI_BRIDGE_FAILURE
-CLEAR
Alarm clear: EH PCI Bridge Failure
13710
EH_SERDES_BUS_ERROR
-SET
Alarm Set: EH Serdes Bus Error
13711
EH_SERDES_BUS_ERROR
-CLEAR
Alarm clear: EH Serdes Bus Error
13720
EH_CHESS_IN_USE-SET
Alarm Set: EH Chess In Use
13721
EH_CHESS_IN_USECLEAR
Alarm clear: EH Chess In Use
13730
EH_ILLEGAL_CHESS_REL
EASE-SET
Alarm Set: EH Illegal Chess Release
13731
EH_ILLEGAL_CHESS_REL
EASE-CLEAR
Alarm clear: EH Illegal Chess Release
13740
EH_ILLEGAL_CHESS_NAM
E-SET
Alarm Set: EH Illegal Chess Name
13741
EH_ILLEGAL_CHESS_NAM
E-CLEAR
Alarm clear: EH Illegal Chess Name
13750
NVR_MAC_ADDR_CORRU
PTION-SET
Alarm Set: NVR MAC ADDR Corruption
13751
NVR_MAC_ADDR_CORRU
PTION-CLEAR
Alarm clear: NVR MAC ADDR Corruption
(U2)
Page - 232 - of 324
Jan 28, 2021 Rev 4.2
Kulicke & Soffa™
SECS/GEM Interface for K&S Ball Bonders
Bonder software version x-xx-x-473-series
IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Collection Events
CEID
Name
Description
13760
NVR_PROT_MEM_CORRU
PTION-SET
Alarm Set: NVR PROT MEM Corruption
13761
NVR_PROT_MEM_CORRU
PTION-CLEAR
Alarm clear: NVR PROT MEM Corruption
13770
NVR_GENERAL_MEM_CO
RRUPTION-SET
Alarm Set: NVR General MEM Corruption
13771
NVR_GENERAL_MEM_CO
RRUPTION-CLEAR
Alarm clear: NVR General MEM Corruption
13780
EH-BOOT-PARM-SAVEERR-SET
Alarm Set: EH Boot Parm Save Error
13781
EH-BOOT-PARM-SAVEERR-CLEAR
Alarm clear: EH Boot Parm Save Error
13790
EH-BOOT-PARM-SET-ERRSET
Alarm Set: EH Boot Parm Set Error
13791
EH-BOOT-PARM-SET-ERRCLEAR
Alarm clear: EH Boot Parm Set Error
13800
EH-BOOT-PARMRESTORE-ERR-SET
Alarm Set: EH Boot Parm Restore Error
13801
EH-BOOT-PARMRESTORE-ERR-CLEAR
Alarm clear: EH Boot Parm Restore Error
13810
EH-INSTALL-KERNELCOPY-ERR-SET
Alarm Set: EH Install Kernel Copy Error
13811
EH-INSTALL-KERNELCOPY-ERR-CLEAR
Alarm clear: EH Install Kernel Copy Error
13820
EH-INSTALL-PROCESSERR-SET
Alarm Set: EH Install Process Error
13821
EH-INSTALL-PROCESSERR-CLEAR
Alarm clear: EH Install Process Error
13830
VDKError_kUnknownThread
Type-SET
Alarm Set: VDKError kUnknownThreadType
13831
VDKError_kUnknownThread
Type-CLEAR
Alarm clear: VDKError kUnknownThreadType
13840
VDKError_kUnknownThread
-SET
Alarm Set: VDKError kUnknownThread
13841
VDKError_kUnknownThread
-CLEAR
Alarm clear: VDKError kUnknownThread
13850
VDKError_kThreadCreationF
ailure-SET
Alarm Set: VDKError kThreadCreationFailure
13851
VDKError_kThreadCreationF
ailure-CLEAR
Alarm clear: VDKError kThreadCreationFailure
(U2)
Page - 233 - of 324
Jan 28, 2021 Rev 4.2
Kulicke & Soffa™
SECS/GEM Interface for K&S Ball Bonders
Bonder software version x-xx-x-473-series
IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Collection Events
CEID
Name
Description
13860
VDKError_kUnknownSemap
hore-SET
Alarm Set: VDKError kUnknownSemaphore
13861
VDKError_kUnknownSemap
hore-CLEAR
Alarm clear: VDKError kUnknownSemaphore
13870
VDKError_kUnknownEventB
it-SET
Alarm Set: VDKError kUnknownEventBit
13871
VDKError_kUnknownEventB
it-CLEAR
Alarm clear: VDKError kUnknownEventBit
13880
VDKError_kUnknownEventSET
Alarm Set: VDKError kUnknownEvent
13881
VDKError_kUnknownEventCLEAR
Alarm clear: VDKError kUnknownEvent
13890
VDKError_kInvalidPrioritySET
Alarm Set: VDKError kInvalidPriority
13891
VDKError_kInvalidPriorityCLEAR
Alarm clear: VDKError kInvalidPriority
13900
VDKError_kInvalidDelaySET
Alarm Set: VDKError kInvalidDelay
13901
VDKError_kInvalidDelayCLEAR
Alarm clear: VDKError kInvalidDelay
13910
VDKError_kSemaphoreTime
out-SET
Alarm Set: VDKError kSemaphore Time Out
13911
VDKError_kSemaphoreTime
out-CLEAR
Alarm clear: VDKError kSemaphore Time Out
13920
VDKError_kEventTimeoutSET
Alarm Set: VDKError kEvent Time Out
13921
VDKError_kEventTimeoutCLEAR
Alarm clear: VDKError kEvent Time Out
13930
VDKError_kBlockInInvalidRe
gion-SET
Alarm Set: VDKError kBlockInInvalidRegion
13931
VDKError_kBlockInInvalidRe
gion-CLEAR
Alarm clear: VDKError kBlockInInvalidRegion
13940
VDKError_kDbgPossibleBloc
kInRegion-SET
Alarm Set: VDKError kDbgPossibleBlockInRegion
13941
VDKError_kDbgPossibleBloc
kInRegion-CLEAR
Alarm clear: VDKError kDbgPossibleBlockInRegion
13950
VDKError_kInvalidPeriodSET
Alarm Set: VDKError kInvaldPeriod
13951
VDKError_kInvalidPeriodCLEAR
Alarm clear: VDKError kInvaldPeriod
(U2)
Page - 234 - of 324
Jan 28, 2021 Rev 4.2
Kulicke & Soffa™
SECS/GEM Interface for K&S Ball Bonders
Bonder software version x-xx-x-473-series
IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Collection Events
CEID
Name
Description
13960
VDKError_kAlreadyPeriodicSET
Alarm Set: VDKError kAlreadyPeriodic
13961
VDKError_kAlreadyPeriodicCLEAR
Alarm clear: VDKError kAlreadyPeriodic
13970
VDKError_kNonperiodicSem
aphore-SET
Alarm Set: VDkError kNonperiodicSemaphore
13971
VDKError_kNonperiodicSem
aphore-CLEAR
Alarm clear: VDkError kNonperiodicSemaphore
13980
VDKError_kDbgPopUnderflo
w-SET
Alarm Set: VDKError kDbgPopUnderFlow
13981
VDKError_kDbgPopUnderflo
w-CLEAR
Alarm clear: VDKError kDbgPopUnderFlow
13990
VDKError_kBadIOID-SET
Alarm Set: VDKError kBadIOID
13991
VDKError_kBadIOID-CLEAR
Alarm clear: VDKError kBadIOID
14000
VDKError_kBadDeviceDescr
iptor-SET
Alarm Set: VDKError kBadDeviceDescriptor
14001
VDKError_kBadDeviceDescr
iptor-CLEAR
Alarm clear: VDKError kBadDeviceDescriptor
14010
VDKError_kOpenFailureSET
Alarm Set: VDKError kOpenFailure
14011
VDKError_kOpenFailureCLEAR
Alarm clear: VDKError kOpenFailure
14020
VDKError_kCloseFailureSET
Alarm Set: VDKError kCloseFailure
14021
VDKError_kCloseFailureCLEAR
Alarm clear: VDKError kCloseFailure
14030
VDKError_kReadFailureSET
Alarm Set: VDKError kReadFailure
14031
VDKError_kReadFailureCLEAR
Alarm clear: VDKError kReadFailure
14040
VDKError_kWriteFailureSET
Alarm Set: VDKError kWriteFailure
14041
VDKError_kWriteFailureCLEAR
Alarm clear: VDKError kWriteFailure
14050
VDKError_kIOCtlFailureSET
Alarm Set: VDKError kIOCtlFailure
14051
VDKError_kIOCtlFailureCLEAR
Alarm clear: VDKError kIOCtlFailure
14060
VDKError_kInvalidDeviceFla
g-SET
Alarm Set: VDKError kInvalidDeviceFlag
(U2)
Page - 235 - of 324
Jan 28, 2021 Rev 4.2
Kulicke & Soffa™
SECS/GEM Interface for K&S Ball Bonders
Bonder software version x-xx-x-473-series
IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Collection Events
CEID
Name
Description
14061
VDKError_kInvalidDeviceFla
g-CLEAR
Alarm clear: VDKError kInvalidDeviceFlag
14070
VDKError_kDeviceTimeoutSET
Alarm Set: VDKError kDeviceTimeOut
14071
VDKError_kDeviceTimeoutCLEAR
Alarm clear: VDKError kDeviceTimeOut
14080
VDKError_kDeviceFlagCreat
ionFailure-SET
Alarm Set: VDKError kDeviceFlagCreationFailure
14081
VDKError_kDeviceFlagCreat
ionFailure-CLEAR
Alarm clear: VDKError kDeviceFlagCreationFailure
14090
VDKError_kMaxCountExcee
ded-SET
Alarm Set: VDKError kMaxCountExceeded
14091
VDKError_kMaxCountExcee
ded-CLEAR
Alarm clear: VDKError kMaxCountExceeded
14100
VDKError_kSemaphoreCrea
tionFailure-SET
Alarm Set: VDKError kSemaphoreCreationFailure
14101
VDKError_kSemaphoreCrea
tionFailure-CLEAR
Alarm clear: VDKError kSemaphoreCreationFailure
14110
VDKError_kSemaphoreDestr
uctionFailure-SET
Alarm Set: VDKError kSemaphoreDestructionFailure
14111
VDKError_kSemaphoreDestr
uctionFailure-CLEAR
Alarm clear: VDKError kSemaphoreDestructionFailure
14120
VDKError_kPoolCreationFail
ure-SET
Alarm Set: VDKError kPoolCreationFailure
14121
VDKError_kPoolCreationFail
ure-CLEAR
Alarm clear: VDKError kPoolCreationFailure
14130
VDKError_kInvalidBlockPoin
ter-SET
Alarm Set: VDKError kInvalidBlockPointer
14131
VDKError_kInvalidBlockPoin
ter-CLEAR
Alarm clear: VDKError kInvalidBlockPointer
14140
VDKError_kInvalidPoolParm
s-SET
Alarm Set: VDKError kInvalidPoolParms
14141
VDKError_kInvalidPoolParm
s-CLEAR
Alarm clear: VDKError kInvalidPoolParms
14150
VDKError_kInvalidPoolIDSET
Alarm Set: VDKError kInvalidPoolID
14151
VDKError_kInvalidPoolIDCLEAR
Alarm clear: VDKError kInvalidPoolID
14160
VDKError_kErrorPoolNotEm
pty-SET
Alarm Set: VDKError kErrorPoolNotEmpty
(U2)
Page - 236 - of 324
Jan 28, 2021 Rev 4.2
Kulicke & Soffa™
SECS/GEM Interface for K&S Ball Bonders
Bonder software version x-xx-x-473-series
IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Collection Events
CEID
Name
Description
14161
VDKError_kErrorPoolNotEm
pty-CLEAR
Alarm clear: VDKError kErrorPoolNotEmpty
14170
VDKError_kErrorMallocBlock
-SET
Alarm Set: VDKError kErrorMallocBlock
14171
VDKError_kErrorMallocBlock
-CLEAR
Alarm clear: VDKError kErrorMallocBlock
14180
VDKError_kMessageCreatio
nFailure-SET
Alarm Set: VDKError kMessageCreationFailure
14181
VDKError_kMessageCreatio
nFailure-CLEAR
Alarm clear: VDKError kMessageCreationFailure
14190
VDKError_kInvalidMessageI
D-SET
Alarm Set: VDKError kInvalidMessageID
14191
VDKError_kInvalidMessageI
D-CLEAR
Alarm clear: VDKError kInvalidMessageID
14200
VDKError_kInvalidMessage
Owner-SET
Alarm Set: VDKError kInvalidMessageOwner
14201
VDKError_kInvalidMessage
Owner-CLEAR
Alarm clear: VDKError kInvalidMessageOwner
14210
VDKError_kInvalidMessage
Channel-SET
Alarm Set: VDKError kInvalidMessageChannel
14211
VDKError_kInvalidMessage
Channel-CLEAR
Alarm clear: VDKError kInvalidMessageChannel
14220
VDKError_kMessageTimeou
t-SET
Alarm Set: VDKError kMessageTimeOut
14221
VDKError_kMessageTimeou
t-CLEAR
Alarm clear: VDKError kMessageTimeOut
14230
VDKError_kMessageInQueu
e-SET
Alarm Set: VDKError kMessageInQueue
14231
VDKError_kMessageInQueu
e-CLEAR
Alarm clear: VDKError kMessageInQueue
14240
TCPError_ENOBUFS-SET
Alarm Set: TCPError ENOBUFS
14241
TCPError_ENOBUFSCLEAR
Alarm clear: TCPError ENOBUFS
14250
TCPError_ETIMEDOUTSET
Alarm Set: TCPError ETIMEDOUT
14251
TCPError_ETIMEDOUTCLEAR
Alarm clear: TCPError ETIMEDOUT
14260
TCPError_EISCONN-SET
Alarm Set: TCPError EISCONN
14261
TCPError_EISCONNCLEAR
Alarm clear: TCPError EISCONN
(U2)
Page - 237 - of 324
Jan 28, 2021 Rev 4.2
Kulicke & Soffa™
SECS/GEM Interface for K&S Ball Bonders
Bonder software version x-xx-x-473-series
IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Collection Events
CEID
Name
Description
14270
TCPError_EOPNOTSUPPSET
Alarm Set: TCPError EOPNOTSUPP
14271
TCPError_EOPNOTSUPPCLEAR
Alarm clear: TCPError EOPNOTSUPP
14280
TCPError_ECONNABORTE
D-SET
Alarm Set: TCPError ECONNABORTED
14281
TCPError_ECONNABORTE
D-CLEAR
Alarm clear: TCPError ECONNABORTED
14290
TCPError_EWOULDBLOCKSET
Alarm Set: TCPError EWOULDBLOCK
14291
TCPError_EWOULDBLOCKCLEAR
Alarm clear: TCPError EWOULDBLOCK
14300
TCPError_ECONNREFUSE
D-SET
Alarm Set: TCPError ECONNREFUSED
14301
TCPError_ECONNREFUSE
D-CLEAR
Alarm clear: TCPError ECONNREFUSED
14310
TCPError_ECONNRESETSET
Alarm Set: TCPError ECONNRESET
14311
TCPError_ECONNRESETCLEAR
Alarm clear: TCPError ECONNRESET
14320
TCPError_ENOTCONN-SET
Alarm Set: TCPError ENOTCONN
14321
TCPError_ENOTCONNCLEAR
Alarm clear: TCPError ENOTCONN
14330
TCPError_EALREADY-SET
Alarm Set: TCPError EALREADY
14331
TCPError_EALREADYCLEAR
Alarm clear: TCPError EALREADY
14340
TCPError_EINVAL-SET
Alarm Set: TCPError EINVAL
14341
TCPError_EINVAL-CLEAR
Alarm clear: TCPError EINVAL
14350
TCPError_EMSGSIZE-SET
Alarm Set: TCPError EMSGSIZE
14351
TCPError_EMSGSIZECLEAR
Alarm clear: TCPError EMSGSIZE
14360
TCPError_EPIPE-SET
Alarm Set: TCPError EPIPE
14361
TCPError_EPIPE-CLEAR
Alarm clear: TCPError EPIPE
14370
TCPError_EDESTADDRRE
Q-SET
Alarm Set: TCPError EDESTADDRREQ
14371
TCPError_EDESTADDRRE
Q-CLEAR
Alarm clear: TCPError EDESTADDRREQ
14380
TCPError_ESHUTDOWNSET
Alarm Set: TCPError ESHUTDOWN
(U2)
Page - 238 - of 324
Jan 28, 2021 Rev 4.2
Kulicke & Soffa™
SECS/GEM Interface for K&S Ball Bonders
Bonder software version x-xx-x-473-series
IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Collection Events
CEID
Name
Description
14381
TCPError_ESHUTDOWNCLEAR
Alarm clear: TCPError ESHUTDOWN
14390
TCPError_ENOPROTOOPTSET
Alarm Set: TCPError ENOPROTOOPT
14391
TCPError_ENOPROTOOPTCLEAR
Alarm clear: TCPError ENOPROTOOPT
14400
TCPError_EHAVEOOB-SET
Alarm Set: TCPError EHAVEOOB
14401
TCPError_EHAVEOOBCLEAR
Alarm clear: TCPError EHAVEOOB
14410
TCPError_ENOMEM-SET
Alarm Set: TCPError ENOMEM
14411
TCPError_ENOMEMCLEAR
Alarm clear: TCPError ENOMEM
14420
TCPError_EADDRNOTAVAI
L-SET
Alarm Set: TCPError EADDRNOTAVAIL
14421
TCPError_EADDRNOTAVAI
L-CLEAR
Alarm clear: TCPError EADDRNOTAVAIL
14430
TCPError_EADDRINUSESET
Alarm Set: TCPError EADDRINUSE
14431
TCPError_EADDRINUSECLEAR
Alarm clear: TCPError EADDRINUSE
14440
TCPError_EAFNOSUPPOR
T-SET
Alarm Set: TCPError EAFNOSUPPORT
14441
TCPError_EAFNOSUPPOR
T-CLEAR
Alarm clear: TCPError EAFNOSUPPORT
14450
TCPError_EINPROGRESSSET
Alarm Set: TCPError EINPROGRESS
14451
TCPError_EINPROGRESSCLEAR
Alarm clear: TCPError EINPROGRESS
14460
TCPError_ELOWER-SET
Alarm Set: TCPError ELOWER
14461
TCPError_ELOWER-CLEAR
Alarm clear: TCPError ELOWER
14470
TCPError_KN_EBADF-SET
Alarm Set: TCPError KN EBADF
14471
TCPError_KN_EBADFCLEAR
Alarm clear: TCPError KN EBADF
14480
TCPError_EIEIO-SET
Alarm Set: TCPError EIEIO
14481
TCPError_EIEIO-CLEAR
Alarm clear: TCPError EIEIO
14490
PBI_BALL_RETEACH_REQ
UIRED-SET
Alarm Set: PBI BALL RETEACH REQUIRED
14491
PBI_BALL_RETEACH_REQ
UIRED-CLEAR
Alarm clear: PBI BALL RETEACH REQUIRED
(U2)
Page - 239 - of 324
Jan 28, 2021 Rev 4.2
Kulicke & Soffa™
SECS/GEM Interface for K&S Ball Bonders
Bonder software version x-xx-x-473-series
IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Collection Events
CEID
Name
Description
14500
EH_EJECT_MAG_FLASHSET
Alarm Set: EH Eject MAG Flash
14501
EH_EJECT_MAG_FLASHCLEAR
Alarm clear: EH Eject MAG Flash
14510
O_MAG_EJECT_THRESHO
LD_WARNING_HEADERSET
Alarm Set: Output MAG Eject Threshold Warning Header
14511
O_MAG_EJECT_THRESHO
LD_WARNING_HEADERCLEAR
Alarm clear: Output MAG Eject Threshold Warning Header
14520
INV_POWERSAVE_PRM_D
ATA_PTR-SET
Alarm Set: INV Powersave PRM Data PTR
14521
INV_POWERSAVE_PRM_D
ATA_PTR-CLEAR
Alarm clear: INV Powersave PRM Data PTR
14530
PAD-FOR-PBI-NOTFOUND-SET
Alarm Set: PAD For PBI Not Found
14531
PAD-FOR-PBI-NOTFOUND-CLEAR
Alarm clear: PAD For PBI Not Found
14540
BALL-EXPECT-OUT-OFPAD-SET
Alarm Set: Ball Expect Out Of Pad
14541
BALL-EXPECT-OUT-OFPAD-CLEAR
Alarm clear: Ball Expect Out Of Pad
14550
EH_AUTO_CONSECUTIVE
_FALSE_PRS_NSOP-SET
Alarm Set: EH Auto Consecutive False PRS NSOP
14551
EH_AUTO_CONSECUTIVE
_FALSE_PRS_NSOPCLEAR
Alarm clear: EH Auto Consecutive False PRS NSOP
14560
AUTO_XHAIR_MAP_INACT
IVE-SET
Alarm Set: Auto Xhair Map Inactive
14561
AUTO_XHAIR_MAP_INACT
IVE-CLEAR
Alarm clear: Auto Xhair Map Inactive
14570
BHLIFTER_AIR_AUTO-SET
Alarm Set: BHLIFTER AIR Auto
14571
BHLIFTER_AIR_AUTOCLEAR
Alarm clear: BHLIFTER AIR Auto
14580
BHLIFTER_AIR_MSTOPSET
Alarm Set: BHLIFTER AIR Mstop
14581
BHLIFTER_AIR_MSTOPCLEAR
Alarm clear: BHLIFTER AIR Mstop
14590
EH_INIT_FOCUS_MOTOR_
STEPPER_FAILED-SET
Alarm Set: EH INIT Focus Motor Stepper Failed
(U2)
Page - 240 - of 324
Jan 28, 2021 Rev 4.2
Kulicke & Soffa™
SECS/GEM Interface for K&S Ball Bonders
Bonder software version x-xx-x-473-series
IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Collection Events
CEID
Name
Description
14591
EH_INIT_FOCUS_MOTOR_
STEPPER_FAILED-CLEAR
Alarm clear: EH INIT Focus Motor Stepper Failed
14600
EH_FATAL_IDX_NOT_FOU
ND-SET
Alarm Set: EH Fatal IDX Not Found
14601
EH_FATAL_IDX_NOT_FOU
ND-CLEAR
Alarm clear: EH Fatal IDX Not Found
14610
IND_NO_CLAMP_VACUUM
_CONT-SET
Alarm Set: IND NO Clamp Vacuum Cont
14611
IND_NO_CLAMP_VACUUM
_CONT-CLEAR
Alarm clear: IND NO Clamp Vacuum Cont
14620
IND_CLAMP_VACUUM_OF
F_FAIL-SET
Alarm Set: IND Clamp Vacuum OFF Fail
14621
IND_CLAMP_VACUUM_OF
F_FAIL-CLEAR
Alarm clear: IND Clamp Vacuum OFF Fail
14630
RAIL_LIMIT_AT_BONDSITE
-SET
Alarm Set: Rail Limit At Bondsite
14631
RAIL_LIMIT_AT_BONDSITE
-CLEAR
Alarm clear: Rail Limit At Bondsite
14640
RAIL_LIMIT_OUTSIDE_BO
NDSITE-SET
Alarm Set: Rail Limit Outside Bondsite
14641
RAIL_LIMIT_OUTSIDE_BO
NDSITE-CLEAR
Alarm clear: Rail Limit Outside Bondsite
14650
AUTO-WIRE-USAGEEXPIRY-SET
Alarm Set: Auto Wire Usage Expiry
14651
AUTO-WIRE-USAGEEXPIRY-CLEAR
Alarm clear: Auto Wire Usage Expiry
14660
EH-INSTALL-USB-COPYERROR-SET
Alarm Set: EH Install USB Copy Error
14661
EH-INSTALL-USB-COPYERROR-CLEAR
Alarm clear: EH Install USB Copy Error
14670
RWH_PN_CMD_FAILURESET
Alarm Set: RWH PN CMD Failure
14671
RWH_PN_CMD_FAILURECLEAR
Alarm clear: RWH PN CMD Failure
14680
MHS_INDEXER_EXCEED_
WHL_LIMIT-SET
Alarm Set: MHS Indexer Exceed WHL Limit
14681
MHS_INDEXER_EXCEED_
WHL_LIMIT-CLEAR
Alarm clear: MHS Indexer Exceed WHL Limit
14690
IMH_UNLOAD_FAIL-SET
Alarm Set: IMH Unload Fail
14691
IMH_UNLOAD_FAIL-CLEAR
Alarm clear: IMH Unload Fail
(U2)
Page - 241 - of 324
Jan 28, 2021 Rev 4.2
Kulicke & Soffa™
SECS/GEM Interface for K&S Ball Bonders
Bonder software version x-xx-x-473-series
IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Collection Events
CEID
Name
Description
14700
OMH_UNLOAD_FAIL-SET
Alarm Set: OMH Unload Fail
14701
OMH_UNLOAD_FAILCLEAR
Alarm clear: OMH Unload Fail
14710
MH_WAIT_STORE_MAGSET
Alarm Set: MH Wait Store MAG
14711
MH_WAIT_STORE_MAGCLEAR
Alarm clear: MH Wait Store MAG
14720
MH_WAIT_STORE_MAG_O
-SET
Alarm Set: MH Wait Store MAG O
14721
MH_WAIT_STORE_MAG_O
-CLEAR
Alarm clear: MH Wait Store MAG O
14730
EJECT_INPUT_MAGAZINE
_NOT_EMPTY-SET
Alarm Set: Eject Input Magazine Not Empty
14731
EJECT_INPUT_MAGAZINE
_NOT_EMPTY-CLEAR
Alarm clear: Eject Input Magazine Not Empty
14740
MH_LOAD_MAG_PUSHER
_PUSH_FAIL-SET
Alarm Set: MH Load MAG Pusher Push Fail
14741
MH_LOAD_MAG_PUSHER
_PUSH_FAIL-CLEAR
Alarm clear: MH Load MAG Pusher Push Fail
14750
MH_LOAD_MAG_PUSHER
_PUSH_FAIL_O-SET
Alarm Set: MH Load MAG Pusher Push Fail O
14751
MH_LOAD_MAG_PUSHER
_PUSH_FAIL_O-CLEAR
Alarm clear: MH Load MAG Pusher Push Fail O
14760
MH_UNLOAD_MAG_PUSH
ER_PUSH_FAIL-SET
Alarm Set: MH Unload MAG Pusher Push Fail
14761
MH_UNLOAD_MAG_PUSH
ER_PUSH_FAIL-CLEAR
Alarm clear: MH Unload MAG Pusher Push Fail
14770
MH_UNLOAD_MAG_PUSH
ER_PUSH_FAIL_O-SET
Alarm Set: MH Unload MAG Pusher Push Fail O
14771
MH_UNLOAD_MAG_PUSH
ER_PUSH_FAIL_O-CLEAR
Alarm clear: MH Unload MAG Pusher Push Fail O
14780
MH_LOAD_MAG_PUSHER
_RETRACT_FAIL-SET
Alarm Set: MH Load MAG Pusher Retract Fail
14781
MH_LOAD_MAG_PUSHER
_RETRACT_FAIL-CLEAR
Alarm clear: MH Load MAG Pusher Retract Fail
14790
MH_LOAD_MAG_PUSHER
_RETRACT_FAIL_O-SET
Alarm Set: MH Load MAG Pusher Retract Fail O
14791
MH_LOAD_MAG_PUSHER
_RETRACT_FAIL_OCLEAR
Alarm clear: MH Load MAG Pusher Retract Fail O
(U2)
Page - 242 - of 324
Jan 28, 2021 Rev 4.2
Kulicke & Soffa™
SECS/GEM Interface for K&S Ball Bonders
Bonder software version x-xx-x-473-series
IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Collection Events
CEID
Name
Description
14800
MH_UNLOAD_MAG_PUSH
ER_RETRACT_FAIL-SET
Alarm Set: MH Unload MAG Pusher Retract Fail
14801
MH_UNLOAD_MAG_PUSH
ER_RETRACT_FAILCLEAR
Alarm clear: MH Unload MAG Pusher Retract Fail
14810
MH_UNLOAD_MAG_PUSH
ER_RETRACT_FAIL_OSET
Alarm Set: MH Unload MAG Pusher Retract Fail O
14811
MH_UNLOAD_MAG_PUSH
ER_RETRACT_FAIL_OCLEAR
Alarm clear: MH Unload MAG Pusher Retract Fail O
14820
AUTO-LOCATOR-FINDFAIL-SET
Alarm Set: Auto Locator Fine Fail
14821
AUTO-LOCATOR-FINDFAIL-CLEAR
Alarm clear: Auto Locator Fine Fail
14830
STRIP_MAP_DL_TIMEOUTSET
Alarm Set: Strip Map DL Time Out
14831
STRIP_MAP_DL_TIMEOUTCLEAR
Alarm clear: Strip Map DL Time Out
14840
STRIP_MAP_DL_FAIL-SET
Alarm Set: Strip Map DL Fail
14841
STRIP_MAP_DL_FAILCLEAR
Alarm clear: Strip Map DL Fail
14850
STRIP_MAP_INVALID_SIZE
-SET
Alarm Set: Strip Map Invalid Size
14851
STRIP_MAP_INVALID_SIZE
-CLEAR
Alarm clear: Strip Map Invalid Size
14860
MHS_GRIP_THETA_BIAS_
FAIL-SET
Alarm Set: MHS Grip Theta Bias Fail
14861
MHS_GRIP_THETA_BIAS_
FAIL-CLEAR
Alarm clear: MHS Grip Theta Bias Fail
14870
EH-USB-PWS-MATROXDROP-SET
Alarm Set: EH USB PWS Matrox Drop
14871
EH-USB-PWS-MATROXDROP-CLEAR
Alarm clear: EH USB PWS Matrox Drop
14880
STRIP_MAP_INVALID_OR
G_LOC-SET
Alarm Set: Strip Map Invalid ORG LOC
14881
STRIP_MAP_INVALID_OR
G_LOC-CLEAR
Alarm clear: Strip Map Invalid ORG LOC
14890
PARAM_RULE_ERR-SET
Alarm Set: Param Rule Error
14891
PARAM_RULE_ERRCLEAR
Alarm clear: Param Rule Error
(U2)
Page - 243 - of 324
Jan 28, 2021 Rev 4.2
Kulicke & Soffa™
SECS/GEM Interface for K&S Ball Bonders
Bonder software version x-xx-x-473-series
IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Collection Events
CEID
Name
Description
14900
EH_GUIDE_SENSOR_NOT
_SAFE-SET
Alarm Set: EH Guide Sensor Not Safe
14901
EH_GUIDE_SENSOR_NOT
_SAFE-CLEAR
Alarm clear: EH Guide Sensor Not Safe
14910
EH_GUIDE_SENSOR_NOT
_SAFE_O-SET
Alarm Set: EH Guide Sensor Not Safe O
14911
EH_GUIDE_SENSOR_NOT
_SAFE_O-CLEAR
Alarm clear: EH Guide Sensor Not Safe O
14920
NKG_DONGLE_CHECK_E
RROR-SET
Alarm Set: NKG Dongle Check Error
14921
NKG_DONGLE_CHECK_E
RROR-CLEAR
Alarm clear: NKG Dongle Check Error
14930
STRIP_MAP_HOST_REPLY
_HALT-SET
Alarm Set: Strip Map Host Reply Halt
14931
STRIP_MAP_HOST_REPLY
_HALT-CLEAR
Alarm clear: Strip Map Host Reply Halt
14940
RLS_UNBIAS_FAILED-SET
Alarm Set: RLS UNBIAS Failed
14941
RLS_UNBIAS_FAILEDCLEAR
Alarm clear: RLS UNBIAS Failed
14950
MON-UPS-LOW-BATTERYSET
Alarm Set: MON UPS Low Battery
14951
MON-UPS-LOW-BATTERYCLEAR
Alarm clear: MON UPS Low Battery
14960
PROCESS-BP-HIT-SET
Alarm Set: Process BP HIT
14961
PROCESS-BP-HIT-CLEAR
Alarm clear: Process BP HIT
14970
AUTO-DRP-CHECK-FAILSET
Alarm Set: Auto DRP Check Fail
14971
AUTO-DRP-CHECK-FAILCLEAR
Alarm clear: Auto DRP Check Fail
14980
EH_AUTO_TEMP_OVER_H
I_LIMIT_LINK-SET
Alarm Set: EH Auto Temp Over HI Limit Link
14981
EH_AUTO_TEMP_OVER_H
I_LIMIT_LINK-CLEAR
Alarm clear: EH Auto Temp Over HI Limit Link
14990
EH_AUTO_TEMP_UNDER_
LOW_LIMIT_LINK-SET
Alarm Set: EH Auto Temp Under Low Limit Link
14991
EH_AUTO_TEMP_UNDER_
LOW_LIMIT_LINK-CLEAR
Alarm clear: EH Auto Temp Under Low Limit Link
15000
EH_AUTO_TEMP_OVER_H
I_LIMIT_OPTICS-SET
Alarm Set: EH Auto Temp Over HI Limit Optics
(U2)
Page - 244 - of 324
Jan 28, 2021 Rev 4.2
Kulicke & Soffa™
SECS/GEM Interface for K&S Ball Bonders
Bonder software version x-xx-x-473-series
IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Collection Events
CEID
Name
Description
15001
EH_AUTO_TEMP_OVER_H
I_LIMIT_OPTICS-CLEAR
Alarm clear: EH Auto Temp Over HI Limit Optics
15010
EH_AUTO_TEMP_UNDER_
LOW_LIMIT_OPTICS-SET
Alarm Set: EH Auto Temp Under Low Limit Optics
15011
EH_AUTO_TEMP_UNDER_
LOW_LIMIT_OPTICSCLEAR
Alarm clear: EH Auto Temp Under Low Limit Optics
15020
STRIP_MAP_HOST_REPLY
_ERROR-SET
Alarm Set: Strip Map Host Reply Error
15021
STRIP_MAP_HOST_REPLY
_ERROR-CLEAR
Alarm clear: Strip Map Host Reply Error
15030
EH_SUB_VALIDATION_FAI
LED-SET
Alarm Set: EH SUB Validation Failed
15031
EH_SUB_VALIDATION_FAI
LED-CLEAR
Alarm clear: EH SUB Validation Failed
15040
CAP_CLEANING_REACHIN
G_LIMIT-SET
Alarm Set: Cap Cleaning Reaching Limit
15041
CAP_CLEANING_REACHIN
G_LIMIT-CLEAR
Alarm clear: Cap Cleaning Reaching Limit
15050
EH_DISK_SPACE_FULLSET
Alarm Set: EH Disk Space Full
15051
EH_DISK_SPACE_FULLCLEAR
Alarm clear: EH Disk Space Full
15060
EH_DISK_SPACE_NOT_FU
LL-SET
Alarm Set: EH Disk Space Not Full
15061
EH_DISK_SPACE_NOT_FU
LL-CLEAR
Alarm clear: EH Disk Space Not Full
15070
EH_TEMP_OVER_MAX_LI
MIT-SET
Alarm Set: EH TEMP Over Max Limit
15071
EH_TEMP_OVER_MAX_LI
MIT-CLEAR
Alarm clear: EH TEMP Over Max Limit
15080
I2C_BUS_ERROR-SET
Alarm Set: I2C BUS Error
15081
I2C_BUS_ERROR-CLEAR
Alarm clear: I2C BUS Error
15090
PDT-PULLTST-INIT-ERRSET
Set Pull Test initialization error
15091
PDT-PULLTST-INIT-ERRCLEAR
Clear Pull Test initialization error
15100
CAL_XHAIR_MAP_
UNSUCCESSFUL-SET
Alarm Set:CAL_XHAIR_MAP_ UNSUCCESSFUL-SET
(U2)
Page - 245 - of 324
Jan 28, 2021 Rev 4.2
Kulicke & Soffa™
SECS/GEM Interface for K&S Ball Bonders
Bonder software version x-xx-x-473-series
IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Collection Events
CEID
Name
Description
15101
CAL_XHAIR_MAP_
UNSUCCESSFUL-CLEAR
Alarm Clear:CAL_XHAIR_MAP_ UNSUCCESSFUL-Clear
15110
AUTO_COVER_GAS_BACK
_PRESSURE_HIGH-SET
Alarm Set: digital cover gas back pressure too high
15111
AUTO_COVER_GAS_BACK
_PRESSURE_HIGH-CLEAR
Alarm Clear: digital cover gas back pressure too high
15120
AUTO_COVER_GAS_BACK
_PRESSURE_LOW-SET
Alarm Set: digital cover gas back pressure too low
15121
AUTO_COVER_GAS_BACK
_PRESSURE_LOW-CLEAR
Alarm Clear: Set digital cover gas back pressure too low
15130
PDT-UNEXPECTED-NSOPTIP2-SET
Alarm Set: PDT Unexpected NSOP TIP2
15131
PDT-UNEXPECTED-NSOPTIP2-CLEAR
Alarm Clear: PDT Unexpected NSOP TIP2
15140
EH-PDT-LGBALL-SET
Alarm Set: EH-PDT-LGBALL
15141
EH-PDT-LGBALL-CLEAR
Alarm Clear: EH-PDT-LGBALL
15150
EH_HB_HIT_RAIL_LIMIT_S
WITCH-SET
Alarm Set:EH_HB_HIT_RAIL_LIMIT_SWITCH
15151
EH_HB_HIT_RAIL_LIMIT_S
WITCH-CLEAR
Alarm Clear:EH_HB_HIT_RAIL_LIMIT_SWITCH
15160
EH_BALL_TAIL_INVALIDAT
ION-SET
Alarm Set:EH_BALL_TAIL_INVALIDATION
15161
EH_BALL_TAIL_INVALIDAT
ION-CLEAR
Alarm Clear:EH_BALL_TAIL_INVALIDATION
15170
EH_STRIP_MAP_INVALIDSET
Alarm Set:EH_STRIP_MAP_INVALID
15171
EH_STRIP_MAP_INVALIDCLEAR
Alarm Clear:EH_STRIP_MAP_INVALID
15180
EH_NFS_MOUNT_FAIL_ER
ROR-SET
Alarm Set:EH-NFS-MOUNT-FAIL-ERROR
15181
EH_NFS_MOUNT_FAIL_ER
ROR-CLEAR
Alarm Clear:EH-NFS-MOUNT-FAIL-ERROR
15190
EH_NSOL_AUTO_REBOND
_ATTEMPTED-SET
Alarm Set:EH_NSOL_AUTO_REBOND_ATTEMPTED
15191
EH_NSOL_AUTO_REBOND
_ATTEMPTED-CLEAR
Alarm Clear:EH_NSOL_AUTO_REBOND_ATTEMPTED
15200
EH_NSOL_AUTO_REBOND
_FAILED-SET
Alarm Set:EH_NSOL_AUTO_REBOND_FAILED
15201
EH_NSOL_AUTO_REBOND
_FAILED-CLEAR
Alarm Clear:EH_NSOL_AUTO_REBOND_FAILED
(U2)
Page - 246 - of 324
Jan 28, 2021 Rev 4.2
Kulicke & Soffa™
SECS/GEM Interface for K&S Ball Bonders
Bonder software version x-xx-x-473-series
IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Collection Events
CEID
Name
Description
15210
PUSHER_KIT_RETRACT_F
AILURE-SET
Alarm Set: PUSHER_KIT_RETRACT_FAILURE
15211
PUSHER_KIT_RETRACT_F
AILURE-CLEAR
Alarm Clear: PUSHER_KIT_RETRACT_FAILURE
15220
EH_UNKNOWN_CELL_VER
IFICATION-SET
Alarm Set:EH_UNKNOWN_CELL_VERIFICATION
15221
EH_UNKNOWN_CELL_VER
IFICATION-CLEAR
Alarm Clear:EH_UNKNOWN_CELL_VERIFICATION
15230
CE_AUTO-ALIGN-FINDFAIL-PARTIAL-BONDEDDEV-SET
Alarm Set:CEID for setting event #2322
15231
CE_AUTO-ALIGN-FINDFAIL-PARTIAL-BONDEDDEV-CLEAR
Alarm Clear:CEID for clearing event #2322
15240
WIRE_CLAMP_PM_LIMIT_
EXCEEDED _SET
Alarm Set:Wire Clamp Usage Reached Limit Set
15241
WIRE_CLAMP_PM_LIMIT_
EXCEEDED _CLEAR
Alarm Clear:Wire Clamp Usage Reached Limit Clear
15250
EH_SAFETY_COVER_KIT_
FAILURE-SET
Alarm Set:Set Safety Cover Error
15251
EH_SAFETY_COVER_KIT_
FAILURE-CLEAR
Alarm Clear:Clear Safety Cover Error
15260
FLUID_RATE_OUT_OF_LI
MIT_SET
Alarm Set:Fluid rate out of limit set
15261
FLUID_RATE_OUT_OF_LI
MIT_CLEAR
Alarm Clear:Fluid rate out of limit clear
15270
EH_PRH_VACUUM_ON_FA
IL-SET
Alarm Set:Set Preheat Vacuum is not present Error
15271
EH_PRH_VACUUM_ON_FA
IL-CLEAR
Alarm Clear:Clear Preheat Vacuum is not present Error
15280
EH_RAILS_HOME_SEEK_F
AIL-SET
Alarm Set:Set Rails Home Seek Fail Error
15281
EH_RAILS_HOME_SEEK_F
AIL-CLEAR
Alarm Clear:Clear Rails Home Seek Fail Error
15290
EH_AIR_BLOWER_OUTOF
_LIMIT_W_CONT-SET
Alarm Set:Air Blower Flow Rate Out Of Limit
15291
EH_AIR_BLOWER_OUTOF
_LIMIT_W_CONT-CLEAR
Alarm Clear:Air Blower Flow Rate Out Of Limit
15300
EH_AIR_BLOWER_OUTOF
_LIMIT-SET
Alarm Set:Air Blower Flow Rate Out Of Limit
(U2)
Page - 247 - of 324
Jan 28, 2021 Rev 4.2
Kulicke & Soffa™
SECS/GEM Interface for K&S Ball Bonders
Bonder software version x-xx-x-473-series
IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Collection Events
CEID
Name
Description
15301
EH_AIR_BLOWER_OUTOF
_LIMIT-CLEAR
Alarm Clear:Air Blower Flow Rate Out Of Limit
15310
EH_ORIENT_EYE_POINT_
NOT_FOUND-SET
Search Orientation eye point failded
15311
EH_ORIENT_EYE_POINT_
NOT_FOUND-CLEAR
Search Orientation eye point failded
15320
EH_PERIODIC_EFO_HEIG
H_CHECK_FAIL-SET
Set CEID of periodic EFO height calibration fails
15321
EH_PERIODIC_EFO_HEIG
H_CHECK_FAIL-CLEAR
Clear CEID of periodic EFO height calibration fails
15330
EH_PERIODIC_EFO_HEIG
H_CHECK_OUT_OF_LIMITSET
Set CEID of periodic EFO height calibration out of limit
15331
EH_PERIODIC_EFO_HEIG
H_CHECK_OUT_OF_LIMITCLEAR
Clear CEID of periodic EFO height calibration out of limit
15340
CE_SOS_EVENT-SET
Set SOS_EVENT (alarm)
15341
CE_SOS_EVENT-CLEAR
Clear SOS_EVENT (alarm)
15350
EH_MHS_OHT_EXEC_SEQ
_ERR-SET
Set OHT Sequence Failure
15351
EH_MHS_OHT_EXEC_SEQ
_ERR-CLEAR
Clear OHT Sequence Failure
15360
EH_INPUT_MAG_EJECT_I
NHIBITED-SET
Event indicate EH error EH_INPUT_MAG_EJECT_INHIBITED is
pop up on GUI
15361
EH_INPUT_MAG_EJECT_I
NHIBITED-CLEAR
Event indicate EH error EH_INPUT_MAG_EJECT_INHIBITED is
pop down on GUI
15370
EH_OUTPUT_MAG_EJECT
_INHIBITED-SET
Event indicate EH error EH_OUTPUT_MAG_EJECT_INHIBITED
is pop up on GUI
15371
EH_OUTPUT_MAG_EJECT
_INHIBITED-CLEAR
Event indicate EH error EH_OUTPUT_MAG_EJECT_INHIBITED
is pop down on GUI
15380
EH_INPUT_MAG_EJECT_H
OST_VALIDATION_TIMEO
UT-SET
Event indicate EH error
EH_INPUT_MAG_EJECT_HOST_VALIDATION_TIMEOUT is
pop up on GUI
15381
EH_INPUT_MAG_EJECT_H
OST_VALIDATION_TIMEO
UT-CLEAR
Event indicate EH error
EH_INPUT_MAG_EJECT_HOST_VALIDATION_TIMEOUT is
pop down on GUI
15390
EH_OUTPUT_MAG_EJECT
_HOST_VALIDATION_TIME
OUT-SET
Event indicate EH error
EH_OUTPUT_MAG_EJECT_HOST_VALIDATION_TIMEOUT is
pop up on GUI
(U2)
Page - 248 - of 324
Jan 28, 2021 Rev 4.2
Kulicke & Soffa™
SECS/GEM Interface for K&S Ball Bonders
Bonder software version x-xx-x-473-series
IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Collection Events
CEID
Name
Description
15391
EH_OUTPUT_MAG_EJECT
_HOST_VALIDATION_TIME
OUT-CLEAR
Event indicate EH error
EH_OUTPUT_MAG_EJECT_HOST_VALIDATION_TIMEOUT is
pop down on GUI
15400
EH_WEDGE_VALIDATION_
CHECK_FAIL-SET
Alarm Set:EH_WEDGE_VALIDATION_CHECK_FAIL
15401
EH_WEDGE_VALIDATION_
CHECK_FAIL-CLEAR
Alarm Clear:EH_WEDGE_VALIDATION_CHECK_FAIL
15420
EH_SUBSTRATE_MAP_PA
RSE_FAIL-SET
Alarm Set:Parse Substrate Map Failed
15421
EH_SUBSTRATE_MAP_PA
RSE_FAIL-CLEAR
Alarm Clear:Parse Substrate Map Failed
15430
CMP_COVER_HOME_NOT
_FOUND-SET
Set Clamp cover home not found error
15431
CMP_COVER_HOME_NOT
_FOUND-CLEAR
Clear Clamp cover home not found Error
15440
CMP_COVER_NOT_OUT_
OF_HOME-SET
Set Clamp cover is not out of home error
15441
CMP_COVER_NOT_OUT_
OF_HOME-CLEAR
Clear Clamp cover is not out of home Error
15450
EH_HB_SECURE_VACUU
M_FAIL-SET
Set EH_HB_SECURE_VACUUM_FAIL error
15451
EH_HB_SECURE_VACUU
M_FAIL-CLEAR
Clear EH_HB_SECURE_VACUUM_FAIL error
15460
EH_GCK_GAS_LOW-SET
Set EH_GCK_GAS_LOW
15461
EH_GCK_GAS_LOWCLEAR
Clear EH_GCK_GAS_LOW
15470
EH_GCK_GAS_LOW_IN_B
ONDING-SET
Set EH_GCK_GAS_LOW_IN_BONDING
15471
EH_GCK_GAS_LOW_IN_B
ONDING-CLEAR
Clear EH_GCK_GAS_LOW_IN_BONDING
15480
EH_MAG_MOTION_INTER
RUPT-SET
Set magazine motion interrupt error
15481
EH_MAG_MOTION_INTER
RUPT-CLEAR
Clear magazine motion interrupt error
15490
PUSHER_KIT_HOME_SEN
SOR_ERROR-SET
Alarm set: Pusher Kit home sensor has some error
15491
PUSHER_KIT_HOME_SEN
SOR_ERROR-CLEAR
Alarm clear: Pusher Kit home sensor has some error
15500
EH_FOCUS_ADJ_OUT_OF
_LIMIT-SET
Set for EH #2378
(U2)
Page - 249 - of 324
Jan 28, 2021 Rev 4.2
Kulicke & Soffa™
SECS/GEM Interface for K&S Ball Bonders
Bonder software version x-xx-x-473-series
IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Collection Events
CEID
Name
Description
15501
EH_FOCUS_ADJ_OUT_OF
_LIMIT-CLEAR
Clear for EH #2378
15510
EH_PDT_RPMOUTLIER_E
RROR-SET
Alarm set: RPM single-outlier error triggered
15511
EH_PDT_RPMOUTLIER_E
RROR-CLEAR
Alarm clear: RPM single-outlier error cleared
15520
EH_CNG_BOND_COUNTE
RS_EXCEEDED-SET
Alarm set: configured bond counter limit exceed
15521
EH_CNG_BOND_COUNTE
RS_EXCEEDED-CLEAR
Alarm clear: configured bond counter limit exceed
15530
EH_CNG_BOND_COUNTE
RS_STOP_AUTO-SET
Alarm set: configured bond counter limit exceed and stop auto
15531
EH_CNG_BOND_COUNTE
RS_STOP_AUTO-CLEAR
Alarm clear: configured bond counter limit exceed and stop auto
15540
EH_FAINT6_GUI_ERR-SET
Set notification “GUI Task Exception. Machine reboot is required”
15541
EH_FAINT6_GUI_ERRCLEAR
Clear notification, “GUI Task Exception. Machine reboot is
required”
15550
EH_REALTIME_RPM_ERR
OR-SET
Realtime RPM error set
15551
EH_REALTIME_RPM_ERR
OR-CLEAR
Realtime RPM error clear
15560
EH_CLXC_BASE_TEMP_T
HRESHOLD_EXCEEDEDSET
Set CLXC base temperature threshold exceeded error
15561
EH_CLXC_BASE_TEMP_T
HRESHOLD_EXCEEDEDCLEAR
Clear CLXC base temperature threshold exceeded error
15570
EH_MH_CHUTE_CLAMP_F
AILED-SET
Set EH_MH_CHUTE_CLAMP_FAILED
15571
EH_MH_CHUTE_CLAMP_F
AILED-CLEAR
Clear EH_MH_CHUTE_CLAMP_FAILED
15580
EH_MH_CHUTE_CLAMP_F
AILED_O-SET
Set EH_MH_CHUTE_CLAMP_FAILED_O
15581
EH_MH_CHUTE_CLAMP_F
AILED_O-CLEAR
Clear EH_MH_CHUTE_CLAMP_FAILED_O
15590
STRIP_ID_NOT_FOUND_IN
_LOCAL_SERVER-SET
Set alarm of strip ID not found in local server
15591
STRIP_ID_NOT_FOUND_IN
_LOCAL_SERVER-CLEAR
Clear alarm of strip ID not found in local server
15600
PDT-DIE-HEIGHT-OVERLIMIT-SET
Set PDT DIE Height Over Limit error
(U2)
Page - 250 - of 324
Jan 28, 2021 Rev 4.2
Kulicke & Soffa™
SECS/GEM Interface for K&S Ball Bonders
Bonder software version x-xx-x-473-series
IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Collection Events
CEID
Name
Description
15601
PDT-DIE-HEIGHT-OVERLIMIT-CLEAR
Clear PDT DIE Height Over Limit error
15610
BATTERY_MISMATCH_SE
TTING-SET
Alarm set: BATTERY_MISMATCH_SETTING
15611
BATTERY_MISMATCH_SE
TTING-CLEAR
Alarm clear: BATTERY_MISMATCH_SETTING
15620
AUTO_CALIBRATION_NEA
R_EXPIRATION-SET
Calibration near expiration has been set.
15621
AUTO_CALIBRATION_NEA
R_EXPIRATION-CLEAR
Calibration near expiration has been cleared
15630
AUTO_CALIBRATION_EXPI
RED-SET
Calibration expired has been set.
15631
AUTO_CALIBRATION_EXPI
RED-CLEAR
Calibration expired has been cleared
15640
AUTO_CALIBRATION_EXPI
RED_STOP_INJECT-SET
Calibration expired with stop strip inject has been set.
15641
AUTO_CALIBRATION_EXPI
RED_STOP_INJECTCLEAR
Calibration expired with stop strip inject has been cleared.
15650
MDS_FAULT_DETECTEDSET
Machine Data Collection Fault
15651
MDS_FAULT_DETECTEDCLEAR
Machine Data Collection Fault
15660
MH_BUFFER_RAIL_NOT_E
MPTY-SET
Set MH_BUFFER_RAIL_NOT_EMPTY
15661
MH_BUFFER_RAIL_NOT_E
MPTY-CLEAR
Clear MH_BUFFER_RAIL_NOT_EMPTY
15670
MH_BUFFER_RAIL_NOT_E
MPTY_O-SET
Set MH_BUFFER_RAIL_NOT_EMPTY_0
15671
MH_BUFFER_RAIL_NOT_E
MPTY_O-CLEAR
Clear MH_BUFFER_RAIL_NOT_EMPTY_0
15680
MH_INDEXER_RAIL_NOT_
EMPTY-SET
Set MH_INDEXER_RAIL_NOT_EMPTY
15681
MH_INDEXER_RAIL_NOT_
EMPTY-CLEAR
Clear MH_INDEXER_RAIL_NOT_EMPTY
15690
MH_INDEXER_RAIL_NOT_
EMPTY_O-SET
Set MH_INDEXER_RAIL_NOT_EMPTY_0
15691
MH_INDEXER_RAIL_NOT_
EMPTY_O-CLEAR
Clear MH_INDEXER_RAIL_NOT_EMPTY_0
15700
MH_BUFFER_RAIL_CRR_N
OT_READY-SET
Set MH_BUFFER_RAIL_CRR_NOT_READY
(U2)
Page - 251 - of 324
Jan 28, 2021 Rev 4.2
Kulicke & Soffa™
SECS/GEM Interface for K&S Ball Bonders
Bonder software version x-xx-x-473-series
IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Collection Events
CEID
Name
Description
15701
MH_BUFFER_RAIL_CRR_N
OT_READY-CLEAR
Clear MH_BUFFER_RAIL_CRR_NOT_READY
15710
MH_BUFFER_RAIL_CRR_N
OT_READY_O-SET
Set MH_BUFFER_RAIL_CRR_NOT_READY_0
15711
MH_BUFFER_RAIL_CRR_N
OT_READY_O-CLEAR
Clear MH_BUFFER_RAIL_CRR_NOT_READY_0
15720
MH_INDEXER_RAIL_CRR_
NOT_READY-SET
Set MH_INDEXER_RAIL_CRR_NOT_READY
15721
MH_INDEXER_RAIL_CRR_
NOT_READY-CLEAR
Clear MH_INDEXER_RAIL_CRR_NOT_READY
15730
MH_INDEXER_RAIL_CRR_
NOT_READY_O-SET
Set MH_INDEXER_RAIL_CRR_NOT_READY_0
15731
MH_INDEXER_RAIL_CRR_
NOT_READY_O-CLEAR
Clear MH_INDEXER_RAIL_CRR_NOT_READY_0
15750
EH_COMM_DOWN_BEFOR
E_UPLOAD_STRIP_MAPSET
Set CEID for ALID
EH_COMM_DOWN_BEFORE_UPLOAD_STRIP_MAP
15751
EH_COMM_DOWN_BEFOR
E_UPLOAD_STRIP_MAPCLEAR
Clear CEID for ALID
EH_COMM_DOWN_BEFORE_UPLOAD_STRIP_MAP
15760
PDT_UNEXPECTED_NSOP
_MISSING_BOND-SET
Missing bond detected by bond monitor has been set.
15761
PDT_UNEXPECTED_NSOP
_MISSING_BOND-CLEAR
Missing bond detected by bond monitor has been cleared
15770
EH_STITCH_LIFT_DETECT
ED-SET
Set event lifted stitch bond is detected by Stitch Lift Detection
Feature
15771
EH_STITCH_LIFT_DETECT
ED-CLEAR
Clear event lifted stitch bond is detected by Stitch Lift Detection
Feature
15780
ACCESS_VIOLATION_INP
UT_LOAD-SET
ACCESS_VIOLATION_INPUT_LOAD set
15781
ACCESS_VIOLATION_INP
UT_LOAD-CLEAR
ACCESS_VIOLATION_INPUT_LOAD clear
15790
ACCESS_VIOLATION_OUT
PUT_LOAD-SET
ACCESS_VIOLATION_OUTPUT_LOAD set
15791
ACCESS_VIOLATION_OUT
PUT_LOAD-CLEAR
ACCESS_VIOLATION_OUTPUT_LOAD clear
15800
PDT-UNEXPECTEDSTITCH-LIFT-SET
Set PDT Stitch Lift error
15801
PDT-UNEXPECTEDSTITCH-LIFT-CLEAR
Clear PDT Stitch Lift error
(U2)
Page - 252 - of 324
Jan 28, 2021 Rev 4.2
Kulicke & Soffa™
SECS/GEM Interface for K&S Ball Bonders
Bonder software version x-xx-x-473-series
IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Collection Events
CEID
Name
Description
15810
PDT-UNEXPECTEDSTITCH-BREAK-SET
Set PDT Stitch Break error
15811
PDT-UNEXPECTEDSTITCH- BREAK-CLEAR
Clear PDT Stitch Break error
15820
PDT-UNEXPECTEDSTITCH-LIFT-BREAK-SET
Set PDT Stitch Lift/Break error
15821
PDT-UNEXPECTEDSTITCH-LIFT-BREAKCLEAR
Clear PDT Stitch Lift/Break error
15830
MDS_DATA_PURGE_EVEN
T-SET
User warning before purging machine data
15831
MDA_DATA_PURGE_EVEN
T-CLEAR
Clear user warning
15840
EH_INVALID_STRIP_MAPSET
CEID triggered when strip map download failed
15841
EH_INVALID_STRIP_MAPCLEAR
CEID triggered when strip map download failed
15850
KNS_CONNECT_ERRORSET
Set KNS Connect error
15851
KNS_CONNECT_ERRORCLEAR
Clear KNS Connect error
15860
EH_LAST_WIRE_NSOL_RE
BOND_BEF_SKIP_DEVSET
Set Last Wire NSOL Rebond Bef Skip Dev Warning Error
15861
EH_LAST_WIRE_NSOL_RE
BOND_BEF_SKIP_DEVCLEAR
Clear Last Wire NSOL Rebond Bef Skip Dev Warning Error
15870
EH_AUTO_LHM_MAX_LOO
P_HT_EXCEED_WARN_LI
MIT-SET
Alarm Set: Max Loop Height exceeds Warning Limit
15871
EH_AUTO_LHM_MAX_LOO
P_HT_EXCEED_WARN_LI
MIT-CLEAR
Alarm Clear: Max Loop Height exceeds Warning Limit
15880
EH_AUTO_LHM_MAX_LOO
P_HT_EXCEED_ERR_LIMI
T-SET
Alarm Set: Max Loop Height exceeds Error Limit
15881
EH_AUTO_LHM_MAX_LOO
P_HT_EXCEED_ERR_LIMI
T-CLEAR
Alarm Clear: Max Loop Height exceeds Error Limit
15890
EH_AUTO_LHM_EDGE_HE
IGHT_EXCEED_WARN_LIM
IT-SET
Alarm Set: Edge Height exceeds Warning Limit
(U2)
Page - 253 - of 324
Jan 28, 2021 Rev 4.2
Kulicke & Soffa™
SECS/GEM Interface for K&S Ball Bonders
Bonder software version x-xx-x-473-series
IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Collection Events
CEID
Name
Description
15891
EH_AUTO_LHM_EDGE_HE
IGHT_EXCEED_WARN_LIM
IT-CLEAR
Alarm Clear: Edge Height exceeds Warning Limit
15900
EH_AUTO_LHM_EDGE_HE
IGHT_EXCEED_ERR_LIMIT
-SET
Alarm Set: Edge Height exceeds Error Limit
15901
EH_AUTO_LHM_EDGE_HE
IGHT_EXCEED_ERR_LIMIT
-CLEAR
Alarm Clear: Edge Height exceeds Error Limit
15910
EH_AUTO_LHM_RESULT_
VALIDATION_TIMEOUTSET
Alarm Set: Result validation timeout
15911
EH_AUTO_LHM_RESULT_
VALIDATION_TIMEOUTCLEAR
Alarm Clear: Result validation timeout
15920
EH_AUTO_LHM_RESULT_
VALIDATION_FAILED-SET
Alarm Set: Result validation failed
15921
EH_AUTO_LHM_RESULT_
VALIDATION_FAILEDCLEAR
Alarm Clear: Result validation failed
15930
EH_AUTO_LHM_RESULT_
VALIDATION_REJECTEDSET
Alarm Set: Result rejected by host
15931
EH_AUTO_LHM_RESULT_
VALIDATION_REJECTEDCLEAR
Alarm Clear: Result rejected by host
15940
MH_MAG_SEPARATION_E
RR-SET
SETCE for MH_MAG_SEPARATION_ERR
15941
MH_MAG_SEPARATION_E
RR-CLEAR
SETCE for MH_MAG_SEPARATION_ERR
15950
MH_MAG_SEPARATION_E
RR_O-SET
SETCE for MH_MAG_SEPARATION_ERR_O
15951
MH_MAG_SEPARATION_E
RR_O-CLEAR
SETCE for MH_MAG_SEPARATION_ERR_O
15960
MH_PLATFORM_NOT_EM
PTY-SET
Set MH_PLATFORM_NOT_EMPTY
15961
MH_PLATFORM_NOT_EM
PTY-CLEAR
Clear MH_PLATFORM_NOT_EMPTY
15970
MH_PLATFORM_NOT_EM
PTY_O-SET
Set MH_PLATFORM_NOT_EMPTY_O
15971
MH_PLATFORM_NOT_EM
PTY_O-CLEAR
Clear MH_PLATFORM_NOT_EMPTY_O
(U2)
Page - 254 - of 324
Jan 28, 2021 Rev 4.2
Kulicke & Soffa™
SECS/GEM Interface for K&S Ball Bonders
Bonder software version x-xx-x-473-series
IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Collection Events
CEID
Name
Description
15980
MH_FORK_NOT_EMPTYSET
Set MH_FORK_NOT_EMPTY
15981
MH_FORK_NOT_EMPTYCLEAR
Clear MH_FORK_NOT_EMPTY
15990
MH_FORK_NOT_EMPTY_O
-SET
Set MH_FORK_NOT_EMPTY_O
15991
MH_FORK_NOT_EMPTY_O
-CLEAR
Clear MH_FORK_NOT_EMPTY_O
16000
MH_PLATFORM_CRR_NO
T_READY-SET
Set MH_PLATFORM_CRR_NOT_READY
16001
MH_PLATFORM_CRR_NO
T_READY-CLEAR
Clear MH_PLATFORM_CRR_NOT_READY
16010
MH_PLATFORM_CRR_NO
T_READY_O-SET
Set MH_PLATFORM_CRR_NOT_READY_O
16011
MH_PLATFORM_CRR_NO
T_READY_O-CLEAR
Clear MH_PLATFORM_CRR_NOT_READY_O
16020
MH_FOKR_CRR_NOT_REA
DY-SET
Set MH_FOKR_CRR_NOT_READY
16021
MH_FOKR_CRR_NOT_REA
DY-CLEAR
Clear MH_FOKR_CRR_NOT_READY
16030
MH_FOKR_CRR_NOT_REA
DY_O-SET
Set MH_FOKR_CRR_NOT_READY_O
16031
MH_FOKR_CRR_NOT_REA
DY_O-CLEAR
Clear MH_FOKR_CRR_NOT_READY_O
16040
LOADER_BENCH_SEQ_ER
ROR-SET
Set LOADER_BENCH_SEQ_ERROR
16041
LOADER_BENCH_SEQ_ER
ROR-CLEAR
Clear LOADER_BENCH_SEQ_ERROR
16050
EH_SAFETY_INIT_FAILEDSET
Safety module initialize failed set
16051
EH_SAFETY_INIT_FAILEDCLEAR
Safety module initialize failed clear
16060
EH_NSOL_REBOND_BEF_
SKIP_DEV_FAILED-SET
Alarm Set:
(U2)
16061
EH_NSOL_REBOND_BEF_
SKIP_DEV_FAILED-CLEAR
NSOL Rebond Before Skip Device Failed
Alarm Clear:
NSOL Rebond Before Skip Device Failed
16070
AIR_OUT_OF_TOLERANC
E-SET
Air pressure tolerance exceeded
16071
AIR_OUT_OF_TOLERANC
E-CLEAR
Air pressure tolerance exceeded
Page - 255 - of 324
Jan 28, 2021 Rev 4.2
Kulicke & Soffa™
SECS/GEM Interface for K&S Ball Bonders
Bonder software version x-xx-x-473-series
IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Collection Events
CEID
Name
Description
16080
EH_OUTPUT_KICK_HOME
_NOT_FOUND-SET
Output kicker home not found
16081
EH_OUTPUT_KICK_HOME
_NOT_FOUND-CLEAR
Output kicker home not found
16090
EH_OUTPUT_KICK_NOT_
OUT_OF_HOME -SET
Output kicker not out of home
16091
EH_OUTPUT_KICK_NOT_
OUT_OF_HOME -CLEAR
Output kicker not out of home
16100
EH_LEFT_CLAW_HOME_N
OT_FOUND-SET
Left claw home not found
16101
EH_LEFT_CLAW_HOME_N
OT_FOUND-CLEAR
Left claw home not found
16110
EH_LEFT_CLAW_NOT_OU
T_OF_HOME-SET
Left claw not out of home
16111
EH_LEFT_CLAW_NOT_OU
T_OF_HOME-CLEAR
Left claw not out of home
16120
EH_RIGHT_CLAW_HOME_
NOT_FOUND-SET
Right claw home not found
16121
EH_RIGHT_CLAW_HOME_
NOT_FOUND-CLEAR
Right claw home not found
16130
EH_RIGHT_CLAW_NOT_O
UT_OF_HOME-SET
Right claw not out of home
16131
EH_RIGHT_CLAW_NOT_O
UT_OF_HOME-CLEAR
Right claw not out of home
16140
EH_INPUT_KICK_HOME_N
OT_FOUND-SET
Input kicker home not found
16141
EH_INPUT_KICK_HOME_N
OT_FOUND-CLEAR
Input kicker home not found
16150
EH_INPUT_KICK_NOT_OU
T_OF_HOME-SET
Input kicker not out of home
16151
EH_INPUT_KICK_NOT_OU
T_OF_HOME-CLEAR
Input kicker not out of home
16160
EH_BK_CLAMP_HOME_NO
T_FOUND-SET
Clamp home not found
16161
EH_BK_CLAMP_HOME_NO
T_FOUND-CLEAR
Clamp home not found
16170
EH_DOUBLE_LF_DETECT
ED-SET
Double LF detected
16171
EH_DOUBLE_LF_DETECT
ED-CLEAR
Double LF detected
(U2)
Page - 256 - of 324
Jan 28, 2021 Rev 4.2
Kulicke & Soffa™
SECS/GEM Interface for K&S Ball Bonders
Bonder software version x-xx-x-473-series
IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Collection Events
CEID
Name
Description
16180
EH_INPUT_LF_JAM-SET
Input LF jammed
16181
EH_INPUT_LF_JAM-CLEAR
Input LF jammed
16190
EH_MH_MAG_NOT_ON_IN
DEXER-SET
Input mag not on indexer
16191
EH_MH_MAG_NOT_ON_IN
DEXER-CLEAR
Input mag not on indexer
16200
EH_MH_MAG_NOT_ON_IN
DEXER_O-SET
Output mag not on indexer
16201
EH_MH_MAG_NOT_ON_IN
DEXER_O-CLEAR
Output mag not on indexer
16210
CE_SOS_EVENT
Inform Host on an SOS Event – i.e. A CPU- or OS fault or critical
deadloop
16211
CE_ALIVE_EVENT
Alive Event: Inform Host that No CPU-Fault or OS-Fault or
Critical Deadloop has been detected during the Check
16220
EH_MH_MAG_WRONG_OR
IENTATION-SET
Input mag wrong oritentation
16221
EH_MH_MAG_WRONG_OR
IENTATION-CLEAR
Input mag wrong oritentation
16230
EH_MH_MAG_WRONG_OR
IENTATION_O-SET
Output mag wrong orientation
16231
EH_MH_MAG_WRONG_OR
IENTATION_O-CLEAR
Output mag wrong orientation
16240
EH_MH_MAGAZINE_DROP
PED-SET
Input mag dropped
16241
EH_MH_MAGAZINE_DROP
PED-CLEAR
Input mag dropped
16250
EH_MH_MAGAZINE_DROP
PED_O-SET
Output mag dropped
16251
EH_MH_MAGAZINE_DROP
PED_O-CLEAR
Output mag dropped
16260
PDT-EFO-THRESHOLDFAULT-SET
Set Event EFO Limit Exceeded Fault
16261
PDT-EFO-THRESHOLDFAULT-CLEAR
Clear Event EFO Limit Exceeded Fault
16270
EH_PART_REJECTED_BY_
HOST-SET
Alarm set: EH_PART_REJECTED_BY_HOST
16271
EH_PART_REJECTED_BY_
HOST-CLEAR
Alarm clear: EH_PART_REJECTED_BY_HOST
16280
EH_PART_BLOCKED_BY_
HOST-SET
Alarm set: EH_PART_BLOCKED_BY_HOST
(U2)
Page - 257 - of 324
Jan 28, 2021 Rev 4.2
Kulicke & Soffa™
SECS/GEM Interface for K&S Ball Bonders
Bonder software version x-xx-x-473-series
IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Collection Events
CEID
Name
Description
EH_PART_BLOCKED_BY_
HOST-CLEAR
Alarm clear:
(U2)
16281
16290
16291
16300
16301
16310
16311
16320
16321
16330
16331
EH_PART_WARNING_BY_
HOST-SET
EH_PART_WARNING_BY_
HOST-CLEAR
EH_PART_MAP_DLOAD_TI
MEOUT-SET
EH_PART_MAP_DLOAD_TI
MEOUT-CLEAR
EH_PART_MAP_DLOAD_F
AIL-SET
EH_PART_MAP_DLOAD_F
AIL-CLEAR
PART_PROCESS_RSLT_R
EJECTED_BY_HOST-SET
PART_PROCESS_RSLT_R
EJECTED_BY_HOSTCLEAR
PART_PROCESS_RSLT_V
ALIDATION_TIMEOUT-SET
PART_PROCESS_RSLT_V
ALIDATION_TIMEOUTCLEAR
EH_PART_BLOCKED_BY_HOST
Alarm set:
EH_PART_WARNING_BY_HOST
Alarm clear:
EH_PART_WARNING_BY_HOST
Alarm set:
EH_PART_MAP_DLOAD_TIMEOUT
Alarm clear:
EH_PART_MAP_DLOAD_TIMEOUT
Alarm set:
EH_PART_MAP_DLOAD_FAIL
Alarm clear:
EH_PART_MAP_DLOAD_FAIL
Alarm set:
PART_PROCESS_RSLT_REJECTED_BY_HOST
Alarm clear:
PART_PROCESS_RSLT_REJECTED_BY_HOST
Alarm set:
PART_PROCESS_RSLT_VALIDATION_TIMEOUT
Alarm clear:
PART_PROCESS_RSLT_VALIDATION_TIMEOUT
16350
EH_WALL_SENSOR_CHEC
K_FAIL_DURING_EJECT_L
F -SET
Set CEID for ALID
EH_WALL_SENSOR_CHECK_FAIL_DURING_EJECT_LF
16351
EH_WALL_SENSOR_CHEC
K_FAIL_DURING_EJECT_L
F -CLEAR
Clear CEID for ALID
EH_WALL_SENSOR_CHECK_FAIL_DURING_EJECT_LF
16360
INPUT_CONVEYOR_COM
M_ERROR-SET
Set INPUT_CONVEYOR_COMM_ERROR
16361
INPUT_CONVEYOR_COM
M_ERROR-CLEAR
Clear INPUT_CONVEYOR_COMM_ERROR
16370
OUTPUT_CONVEYOR_CO
MM_ERROR-SET
Set OUTPUT_CONVEYOR_COMM_ERROR
16371
OUTPUT_CONVEYOR_CO
MM_ERROR-CLEAR
Clear OUTPUT_CONVEYOR_COMM_ERROR
Page - 258 - of 324
Jan 28, 2021 Rev 4.2
Kulicke & Soffa™
SECS/GEM Interface for K&S Ball Bonders
Bonder software version x-xx-x-473-series
IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Collection Events
CEID
Name
Description
16380
INPUT_CONVEYOR_COM
M_TIMEOUT-SET
Set INPUT_CONVEYOR_COMM_TIMEOUT
16381
INPUT_CONVEYOR_COM
M_TIMEOUT-CLEAR
Clear INPUT_CONVEYOR_COMM_TIMEOUT
16390
OUTPUT_CONVEYOR_CO
MM_TIMEOUT-SET
Set OUTPUT_CONVEYOR_COMM_TIMEOUT
16391
OUTPUT_CONVEYOR_CO
MM_TIMEOUT-CLEAR
Clear OUTPUT_CONVEYOR_COMM_TIMEOUT
16400
INPUT_CONVEYOR_ERRO
R-SET
Set INPUT_CONVEYOR_ERROR
16401
INPUT_CONVEYOR_ERRO
R-CLEAR
Clear INPUT_CONVEYOR_ERROR
16410
OUTPUT_CONVEYOR_ER
ROR-SET
Set OUTPUT_CONVEYOR_ERROR
16411
OUTPUT_CONVEYOR_ER
ROR-CLEAR
Clear OUTPUT_CONVEYOR_ERROR
16420
INPUT_CONVEYOR_WAIT_
UPSTREAM_TIMEOUT-SET
Set INPUT_CONVEYOR_WAIT_UPSTREAM_TIMEOUT
16421
INPUT_CONVEYOR_WAIT_
UPSTREAM_TIMEOUTCLEAR
Clear INPUT_CONVEYOR_WAIT_UPSTREAM_TIMEOUT
16430
OUTPUT_CONVEYOR_WAI
T_DOWNSTREAM_TIMEO
UT-SET
Set OUTPUT_CONVEYOR_WAIT_DOWNSTREAM_TIMEOUT
16431
OUTPUT_CONVEYOR_WAI
T_DOWNSTREAM_TIMEO
UT-CLEAR
Clear
OUTPUT_CONVEYOR_WAIT_DOWNSTREAM_TIMEOUT
16440
CONVEYOR_SAFETY_COV
ER_OPEN-SET
Set CONVEYOR_SAFETY_COVER_OPEN
16441
CONVEYOR_SAFETY_COV
ER_OPEN-CLEAR
Clear CONVEYOR_SAFETY_COVER_OPEN
16450
PREHEAT_NOT_UP-SET
Set PREHEAT_NOT_UP
16451
PREHEAT_NOT_UPCLEAR
Clear PREHEAT_NOT_UP
16460
PREHEAT_NOT_DOWNSET
Set PREHEAT_NOT_DOWN
16461
PREHEAT_NOT_DOWNCLEAR
Clear PREHEAT_NOT_DOWN
16470
INPUT_CONVEYOR_NOT_
READY-SET
Set INPUT_CONVEYOR_NOT_READY
(U2)
Page - 259 - of 324
Jan 28, 2021 Rev 4.2
Kulicke & Soffa™
SECS/GEM Interface for K&S Ball Bonders
Bonder software version x-xx-x-473-series
IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Collection Events
CEID
Name
Description
16471
INPUT_CONVEYOR_NOT_
READY-CLEAR
Clear INPUT_CONVEYOR_NOT_READY
16480
OUTPUT_CONVEYOR_NO
T_READY-SET
Set OUTPUT_CONVEYOR_NOT_READY
16481
OUTPUT_CONVEYOR_NO
T_READY-CLEAR
Clear OUTPUT_CONVEYOR_NOT_READY
16490
INPUT_CONVEYOR_COM
M_TIMEOUT_2-SET
Set INPUT_CONVEYOR_COMM_TIMEOUT_2
16491
INPUT_CONVEYOR_COM
M_TIMEOUT_2-CLEAR
Clear INPUT_CONVEYOR_COMM_TIMEOUT_2
16500
OUTPUT_CONVEYOR_CO
MM_TIMEOUT_2-SET
Set OUTPUT_CONVEYOR_COMM_TIMEOUT_2
16501
OUTPUT_CONVEYOR_CO
MM_TIMEOUT_2-CLEAR
Clear OUTPUT_CONVEYOR_COMM_TIMEOUT_2
16510
EH_NSOP_SKIP_DEV_BY_
BOND_NEXT_WIRE_FAILE
D-SET
Alarm Set:
(U2)
16511
EH_NSOP_SKIP_DEV_BY_
BOND_NEXT_WIRE_FAILE
D-CLEAR
NSOP Skip Device by Bond Next Wire Failed
Alarm Clear:
NSOP Skip Device by Bond Next Wire Failed
16520
EXT_2D_BCR_READ_FAILSET
External 2D BCR read fail alarm set
16521
EXT_2D_BCR_READ_FAILCLEAR
External 2D BCR read fail alarm clear
16530
REMOTE_PARMS_UPLOA
D_FAIL-SET
Set REMOTE_PARMS_UPLOAD_FAIL
16531
REMOTE_PARMS_UPLOA
D_FAIL-CLEAR
Clear REMOTE_PARMS_UPLOAD_FAIL
16540
REMOTE_PARMS_DOWNL
OAD_FAIL-SET
Set REMOTE_PARMS_DOWNLOAD_FAIL
16541
REMOTE_PARMS_DOWNL
OAD_FAIL-CLEAR
Clear REMOTE_PARMS_DOWNLOAD_FAIL
16550
OUT_SLOT_LF_DETECTE
D-SET
Alarm OUT_SLOT_LF_DETECTED set
16551
OUT_SLOT_LF_DETECTE
D-CLEAR
Alarm OUT_SLOT_LF_DETECTED cleared
16560
OMH_LF_RETAINER_NOT_
IN_POS-SET
Alarm OMH_LF_RETAINER_NOT_IN_POS set
16561
OMH_LF_RETAINER_NOT_
IN_POS-CLEAR
Alarm OMH_LF_RETAINER_NOT_IN_POS cleared
Page - 260 - of 324
Jan 28, 2021 Rev 4.2
Kulicke & Soffa™
SECS/GEM Interface for K&S Ball Bonders
Bonder software version x-xx-x-473-series
IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Collection Events
CEID
Name
Description
16570
PDT_PULLTST_OUT_OF_L
IMIT -SET
Set CEID for ALID PDT_PULLTST_OUT_OF_LIMIT
16571
PDT_PULLTST_OUT_OF_L
IMIT -CLEAR
Clear CEID for ALID PDT_PULLTST_OUT_OF_LIMIT
16580
OUT_SLOT_LF_DETECTE
D_2-SET
Alarm OUT_SLOT_LF_DETECTED_2 set
16581
OUT_SLOT_LF_DETECTE
D_2-CLEAR
Alarm OUT_SLOT_LF_DETECTED_2 cleared
16590
EH_BOFF_POS_INVALIDSET
Alarm Set:
(U2)
16591
EH_BOFF_POS_INVALIDCLEAR
Bond Off Position Invalid
Alarm Clear:
Bond Off Position Invalid
16600
EH_MAG_SERVICE_POSISET
Detect EH_MAG_SERVICE_POSI_NEED_RETURN
16601
EH_MAG_SERVICE_POSICLEAR
Clear EH_MAG_SERVICE_POSI_NEED_RETURN
16610
RPM_HEALTH_WARNINGSET
Set RPM_HEALTH_WARNING
16611
RPM_HEALTH_WARNINGCLEAR
Clear RPM_HEALTH_WARNING
16620
RPM_NO_COMMS-SET
Set RPM_NO_COMMS
16621
RPM_NO_COMMS-CLEAR
Clear RPM_NO_COMMS
16630
RPM_SUBSYSTEM_HEALT
H_WARNING-SET
Set RPM_SUBSYSTEM_HEALTH_WARNING
16631
RPM_SUBSYSTEM_HEALT
H_WARNING-CLEAR
Clear RPM_SUBSYSTEM_HEALTH_WARNING
16640
RPM_ANALYTICS_FAULTSET
Set RPM_ANALYTICS_FAULT
16641
RPM_ANALYTICS_FAULTCLEAR
Clear RPM_ANALYTICS_FAULT
16650
EH_Z_LINK_WARM_UP_AB
ORT-SET
Set CEID for ALID EH_Z_LINK_WARM_UP_ABORT
16651
EH_Z_LINK_WARM_UP_AB
ORT-CLEAR
Clear CEID for ALID EH_Z_LINK_WARM_UP_ABORT
16660
BH_CI_COLL_PRE_CONDI
TION_ERR-SET
Set BH_CI_COLL_PRE_CONDITION_ERR
16661
BH_CI_COLL_PRE_CONDI
TION_ERR-CLEAR
Clear BH_CI_COLL_PRE_CONDITION_ERR
Page - 261 - of 324
Jan 28, 2021 Rev 4.2
Kulicke & Soffa™
SECS/GEM Interface for K&S Ball Bonders
Bonder software version x-xx-x-473-series
IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Collection Events
CEID
Name
Description
16670
INPUT_LF_PICKUP_HOME
_NOT_FOUND-SET
VLF fork type input pickup home sensor not found - set
16671
INPUT_LF_PICKUP_HOME
_NOT_FOUND -CLEAR
VLF fork type input pickup home sensor not found - clear
16680
INPUT_LF_PUSHER_HOM
E_NOT_FOUND-SET
VLF fork type input pusher home sensor not found - set
16681
INPUT_LF_PUSHER_HOM
E_NOT_FOUND-CLEAR
VLF fork type input pusher home sensor not found - clear
16690
OUTPUT_LF_GRIPPER_H
OME_NOT_FOUND-SET
VLF fork type output gripper home sensor not found - set
16691
OUTPUT_LF_GRIPPER_H
OME_NOT_FOUND-CLEAR
VLF fork type output gripper home sensor not found - clear
16700
INPUT_MH_EMPTY_FORKSET
VLF fork type on-loader has no fork - set
16701
INPUT_MH_EMPTY_FORKCLEAR
VLF fork type on-loader has no fork - clear
16710
INPUT_LF_PICKUP_DETE
CT_FAIL-SET
VLF fork type input pickup fail to get lead frame - set
16711
INPUT_LF_PICKUP_DETE
CT_FAIL-CLEAR
VLF fork type input pickup fail to get lead frame - clear
16720
INPUT_LF_DROP_ACTION
_FAIL-SET
VLF fork type input pickup fail to drop lead frame on track - set
16721
INPUT_LF_DROP_ACTION
_FAIL-CLEAR
VLF fork type input pickup fail to drop lead frame on track - clear
16730
INPUT_LF_STANDBY_ACTI
ON_FAIL-SET
VLF fork type input pickup fail to go to standby position - set
16731
INPUT_LF_STANDBY_ACTI
ON_FAIL-CLEAR
VLF fork type input pickup fail to go to standby position - clear
16740
INPUT_LF_PUSH_ACTION
_FAIL-SET
VLF fork type input pusher fail to push lead frame in - set
16741
INPUT_LF_PUSH_ACTION
_FAIL-CLEAR
VLF fork type input pusher fail to push lead frame in - clear
16750
OUTPUT_MH_EMPTY_FOR
K-SET
VLF fork type off-loader has no fork - set
16751
OUTPUT_MH_EMPTY_FOR
K-CLEAR
VLF fork type off-loader has no fork - clear
16760
OUTPUT_LF_GRIP_ACTIO
N_FAIL-SET
VLF fork type output gripper action fail - set
16761
OUTPUT_LF_GRIP_ACTIO
N_FAIL-CLEAR
VLF fork type output gripper action fail - clear
(U2)
Page - 262 - of 324
Jan 28, 2021 Rev 4.2
Kulicke & Soffa™
SECS/GEM Interface for K&S Ball Bonders
Bonder software version x-xx-x-473-series
IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Collection Events
CEID
Name
Description
16770
CI_SAFE_POS_SNS_DETE
CT-SET
SETCE for CI_SAFE_POS_SNS_DETECT
16771
CI_SAFE_POS_SNS_DETE
CT-CLEAR
CLEARCE for CI_SAFE_POS_SNS_DETECT
16780
ACC_ALIGNMENT_ERROR
-SET
Set ACC_ALIGNMENT_ERROR
16781
ACC_ALIGNMENT_ERROR
-CLEAR
Clear ACC_ALIGNMENT_ERROR
16790
ACC_ROBOT_ERROR-SET
Set ACC_ROBOT_ERROR
16791
ACC_ROBOT_ERRORCLEAR
Clear ACC_ROBOT_ERROR
16800
RPM_DATAVIZ_FAULTSET
RPM_DATAVIZ_FAULT-SET
16801
RPM_DATAVIZ_FAULTCLEAR
RPM_DATAVIZ_FAULT-CLEAR
16810
EH_PP_AUTO_CONV_FAIL
-SET
Set CEID for ALID EH_PP_AUTO_CONV_FAIL
16811
EH_PP_AUTO_CONV_FAIL
-CLEAR
Clear CEID for ALID EH_PP_AUTO_CONV_FAIL
16820
PREHEAT_VAC_NOT_ONSET
Preheat vacuum not on alarm set
16821
PREHEAT_VAC_NOT_ONCLEAR
Preheat vacuum not on alarm clear
16830
PREHEAT_VAC_NOT_OFFSET
Preheat vacuum not off alarm set
16831
PREHEAT_VAC_NOT_OFFCLEAR
Preheat vacuum not off alarm clear
16840
EH_IDLE_PROMPT_EJECT
_LF_TIMEOUT-SET
for EH EH_IDLE_PROMPT_EJECT_LF_TIMEOUT (Idle Mode
ECO Prompt To Eject Leadframes time out)
16841
EH_IDLE_PROMPT_EJECT
_LF_TIMEOUT-CLEAR
for EH EH_IDLE_PROMPT_EJECT_LF_TIMEOUT (Idle Mode
ECO Prompt To Eject Leadframes time out)
16850
EH_CD_SKIP_PROC_LIMIT
_EXCEEDED-SET
Alarm set: CD skipped processing - exceed limit
16851
EH_CD_SKIP_PROC_LIMIT
_EXCEEDED-CLEAR
Alarm clear: CD skipped processing - exceed limit
16870
INPUT_SMEMA_START_T
RANSFER_TIMEOUT -SET
Set input smema start transfer timeout error
16871
INPUT_SMEMA_START_T
RANSFER_TIMEOUTCLEAR
Clear input smema start transfer timeout error
(U2)
Page - 263 - of 324
Jan 28, 2021 Rev 4.2
Kulicke & Soffa™
SECS/GEM Interface for K&S Ball Bonders
Bonder software version x-xx-x-473-series
IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Collection Events
CEID
Name
Description
16880
INPUT_SMEMA_END_TRA
NSFER_TIMEOUT-SET
Set input smema end transfer timeout error
16881
INPUT_SMEMA_END_TRA
NSFER_TIMEOUT-CLEAR
Clear input smema end transfer timeout error
16890
INPUT_SMEMA_INVALID_A
CK_SIG_STATE-SET
Set input smema invalid acknowledgement signal state error
16891
INPUT_SMEMA_INVALID_A
CK_SIG_STATE-CLEAR
Clear input smema invalid acknowledgement signal state error
16900
WIRE-INSP-WIRE-STOPERR-SET
Alarm set for EH #2560
16901
WIRE-INSP-WIRE-STOPERR-CLEAR
Alarm clear for EH #2560
16910
WIRE-INSP-UNIT-STOPERR-SET
Alarm set for EH #2561
16911
WIRE-INSP-UNIT-STOPERR-CLEAR
Alarm clear for EH #2561
16920
WIRE-INSP-EXCEEDWARN-LIMIT-SET
Alarm set for EH #2562
16921
WIRE-INSP-EXCEEDWARN-LIMIT-CLEAR
Alarm clear for EH #2562
16930
WIRE-INSP-REALIGNFAILURE-SET
Alarm set for EH #2563
16931
WIRE-INSP-REALIGNFAILURE-CLEAR
Alarm clear for EH #2563
16940
EH_Z_LINK_WARM_UP_C
OMPLETED-SET
Set CEID for ALID EH_Z_LINK_WARM_UP_COMPLETED
16941
EH_Z_LINK_WARM_UP_C
OMPLETED-CLEAR
Clear CEID for ALID EH_Z_LINK_WARM_UP_COMPLETED
16950
WIRE-INSP-ID-NOTTAUGHT-SET
Alarm set for WIRE-INSP-ID-NOT-TAUGHT
16951
WIRE-INSP-ID-NOTTAUGHT -CLEAR
Alarm clear for WIRE-INSP-ID-NOT-TAUGHT
16960
CE_ACC_SEQUENCE_ERR
OR_SET
ACC change cap sequence error prompted
16961
CE_ACC_SEQUENCE_ERR
OR_CLEAR
ACC change cap sequence error cleared
16970
CE_ACC_UNDOCKING_ER
ROR_SET
ACC OHT undocking error prompted
16971
CE_ACC_UNDOCKING_ER
ROR_CLEAR
ACC OHT undocking error cleared
(U2)
Page - 264 - of 324
Jan 28, 2021 Rev 4.2
Kulicke & Soffa™
SECS/GEM Interface for K&S Ball Bonders
Bonder software version x-xx-x-473-series
IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Collection Events
CEID
Name
Description
16980
CE_ACC_DOCKING_ERRO
R_SET
ACC OHT docking error prompted
16981
CE_ACC_DOCKING_ERRO
R_CLEAR
ACC OHT docking error cleared
16990
EH_AUTO_LHM_LOOP_HE
IGHT_INVALID-SET
Auto loop height measurement too low or missing set
16991
EH_AUTO_LHM_LOOP_HE
IGHT_INVALID-CLEAR
Auto loop height measurement too low or missing clear
17000
EH_FILE_RENAME_ERRO
R-SET
Set renaming file failure error
17001
EH_FILE_RENAME_ERRO
R-CLEAR
Clear renaming file failure error
17010
MH_BLOCKED_BY_INDEX
ER_ASSEMBLY-SET
Set input mag handler blocked by indexer assembly error
17011
MH_BLOCKED_BY_INDEX
ER_ASSEMBLY-CLEAR
Clear input mag handler blocked by indexer assembly error
17020
INDEXER_ASSEMBLY_INV
ALID_POS-SET
Set indexer assembly invalid position error
17021
INDEXER_ASSEMBLY_INV
ALID_POS-CLEAR
Clear indexer assembly invalid position error
17030
EH_AUTO_BOND_FAB_FAI
L-SET
Set CEID for ALID EH_AUTO_BOND_FAB_FAIL
17031
EH_AUTO_BOND_FAB_FAI
L-CLEAR
Clear CEID for ALID EH_AUTO_BOND_FAB_FAIL
17040
OUTLIER_WARNING-SET
Set OUTLIER_WARNING
17041
OUTLIER_WARNINGCLEAR
Clear OUTLIER_WARNING
17050
EH_AUTO_BOND_SAMPLE
_FAIL-SET
Set CEID for ALID EH_AUTO_BOND_SAMPLE_FAIL
17051
EH_AUTO_BOND_SAMPLE
_FAIL-CLEAR
Clear CEID for ALID EH_AUTO_BOND_SAMPLE_FAIL
17060
AUTO_FORCE_VERIFICATI
ON_FAILED-SET
Set CEID for AUTO_FORCE_VERIFICATION_FAILED
17061
AUTO_FORCE_VERIFICATI
ON_FAILED-CLEAR
Clear CEID for AUTO_FORCE_VERIFICATION_FAILED
17070
PULLTST-ENDING-FORCEREACHED-SET
Set CEID for PULLTST-ENDING-FORCE-REACHED
17071
PULLTST-ENDING-FORCEREACHED-CLEAR
Clear CEID for PULLTST-ENDING-FORCE-REACHED
(U2)
Page - 265 - of 324
Jan 28, 2021 Rev 4.2
Kulicke & Soffa™
SECS/GEM Interface for K&S Ball Bonders
Bonder software version x-xx-x-473-series
IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Collection Events
CEID
Name
Description
17080
MH_FORK_ZAXIS_UPPER_
SENSOR_ON-SET
CIS Loader Z Axis upper sensor on alarm set
17081
MH_FORK_ZAXIS_UPPER_
SENSOR_ON-CLEAR
CIS Loader Z Axis upper sensor on alarm clear
17090
MH_FORK_ZAXIS_UPPER_
SENSOR_ON_O-SET
CIS Unloader Z Axis upper sensor on alarm set
17091
MH_FORK_ZAXIS_UPPER_
SENSOR_ON_O-CLEAR
CIS Unoader Z Axis upper sensor on alarm clear
17100
FORK_ZAXIS_SEEK_TIME
OUT-SET
CIS Loader Z Axis seek sensor time out alarm set
17101
FORK_ZAXIS_SEEK_TIME
OUT-CLEAR
CIS Loader Z Axis seek sensor time out alarm clear
17110
FORK_ZAXIS_SEEK_TIME
OUT_O-SET
CIS Unloader Z Axis seek sensor time out alarm set
17111
FORK_ZAXIS_SEEK_TIME
OUT_O-CLEAR
CIS Unloader Z Axis seek sensor time out alarm clear
17120
MH_FORK_ZAXIS_HOME_
SENSOR_ON-SET
CIS Loader Z Axis home sensor on alarm set
17121
MH_FORK_ZAXIS_HOME_
SENSOR_ON-CLEAR
CIS Loader Z Axis home sensor on alarm clear
17130
MH_FORK_ZAXIS_HOME_
SENSOR_ON_O-SET
CIS Unloader Z Axis home sensor on alarm set
17131
MH_FORK_ZAXIS_HOME_
SENSOR_ON_O-CLEAR
CIS Unoader Z Axis home sensor on alarm clear
17140
EH_EXT_SIG_MONIT_WAR
NING -SET
Set external signal monitor warning
17141
EH_EXT_SIG_MONIT_WAR
NING-CLEAR
Clear external signal monitor warning
17160
MH_CMP_HSS_CHK_ERRSET
Set clamp home sensor check error
17161
MH_CMP_HSS_CHK_ERRCLEAR
Clear clamp home sensor check error
17170
MHS_X_SENSOR_BLOCKE
D-SET
Set CEID for ALID MHS_X_SENSOR_BLOCKED
17171
MHS_X_SENSOR_BLOCKE
D-CLEAR
Clear CEID for ALID MHS_X_SENSOR_BLOCKED
(U2)
Figure 60 – K&S Model Power Series Automatic Ball Bonder and K&S Model Gen-S Automatic Ball Bonder
Shared Collection Events
Page - 266 - of 324
Jan 28, 2021 Rev 4.2
Kulicke & Soffa™
SECS/GEM Interface for K&S Ball Bonders
Bonder software version x-xx-x-473-series
6.5
K&S Model Power Series Automatic Ball Bonder and K&S Model Gen-S Automatic
Ball Bonder Shared Alarms
The Alarms and associated Alarm IDs (ALID) shared by K&S Model Power Series Automatic Ball Bonder and K&S
Model Gen-S Automatic Ball Bonder are described in this section.All alarms listed in the alarm table have two
associated collection events. One is sent when the alarm condition is detected, and the other is sent when the
alarm condition is cleared.
These events use the same names as their associated alarms, with ‘-SET’ or ‘-CLEAR’ appended to the event name,
respectively. The CEID’s for the collection events associated with a given alarm can be derived by taking the last
three digits of the ALID, multiplying by ten and adding 9000 to get the CEID of the collection event used to indicate
that the alarm has been set. Add one to the set collection event CEID to get the CEID of the event used to indicate
the alarm has been cleared. For example, for alarm 6027, the set collection event would be 9270, the clear event
9271.
Page - 267 - of 324
Jan 28, 2021 Rev 4.2
Kulicke & Soffa™
SECS/GEM Interface for K&S Ball Bonders
Bonder software version x-xx-x-473-series
ALID
(U2)
6001
6002
6003
6004
IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Alarms
ALTX
ALCD
Description
PDT-EFO-OPEN
PDT-EFO-SHORT
PDT-EFO-ERROR
EFO-HAZARD
2
2
2
1
PDT-WIREFEEDERROR
MANUAL-EFOOPEN
MANUAL-EFOSHORT
MANUAL-EFOERROR
MANUAL-EFOHAZARD
2
PDT Error - EFO Open
PDT Error - EFO Short
PDT Error - EFO Error
The software self diagnostics indicate error in EFO control code.
Continued operation of EFO may be dangerous. DO NOT
TOUCH THE EFO AREA PRIOR TO DISABLING HIGH
VOLTAGE!
PDT Wire Feed Error
2
Manual Error - EFO Open
2
Manual Error - EFO Short
2
Manual Error - EFO Error
2
5
6011
6012
AUTO-TEMP-OUTOF-LIMITS
FATAL-ERROR
OS-ERROR
The software self diagnostics indicate error in EFO control code.
Continued operation of EFO may be dangerous. DO NOT
TOUCH THE EFO AREA PRIOR TO DISABLING HIGH
VOLTAGE!
Workholder Temperature Out of Set Limit
6013
INTERNAL-ERROR
2
6014
PROCESS-ERROR
6
6015
MHS_MOTOR_DRI
VER_ERROR
IND_DEVICE_OVE
RHEATED
IND_NO_CLAMP_
VACUUM
IND_CARRIER_JA
M
MH_BAD_GRIPPE
R_CHANGE
MON-X-MOTOROVER-TEMP
MON-YL-MOTOROVER-TEMP
MON-YR-MOTOROVER-TEMP
MON-Z-MOTOROVER-TEMP
MON-T-MOTOROVER-TEMP
2
Fatal Error
An Operating System error was detected which was
compensated for.
However, any further operation may
compromise the machine. Secure the material and restart the
machine as soon as possible.
A software error occurred which was compensated for.
However, any further operation may compromise the machine.
Secure the material and restart as soon as possible.
A process error was detected. Machine is designed to handle
these types of errors.
MHS motor driver error
2
Individual device overheated
2
Clamp vacuum not present.
2
Leadframe jammed during ejection.
5
2
Logic Error, Input magazine asked to change gripper size while
mag gripped.
X motor over temperature error.
2
Y motor over temperature error.
2
Y motor over temperature error.
2
Z motor over temperature error.
2
T motor over temperature error.
6005
6006
6007
6008
6009
6010
6016
6017
6018
6019
6022
6023
6024
6025
6026
5
2
Page - 268 - of 324
Jan 28, 2021 Rev 4.2
Kulicke & Soffa™
SECS/GEM Interface for K&S Ball Bonders
Bonder software version x-xx-x-473-series
ALID
(U2)
6027
6028
6029
6030
6031
6032
6033
6034
6035
6036
6037
6038
6039
6040
6041
6042
6043
6044
6045
6046
6047
6048
6049
IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Alarms
ALTX
ALCD
Description
MON-RACKOVER-TEMP
MON-PSUPPLYOVER-TEMP
MON-WIREFEEDAIR-DOWN
MON-SYSTEMAIR-DOWN
MON-STEP1-BDFAULT
MON-STEP2-BDFAULT
TEMP_ZONE_OPE
N_LOOP_ERROR
POWER-FAILURE
POWER-LOW
POWEROVERTEMP
SYSTEM-FAILURE
PFAIL-DETECT
2
Card rack over temperature error.
2
Power supply over temperature error.
2
Wire-feed air is down error.
2
System air is down error.
2
Stepper board 1 any faults occur.
2
Stepper board 2 any faults occur.
2
Temperature Zone has open loop error. Zone was turned off.
5
2
2
Power Failure Detected.
Power Low Detected.
Power Supply Temperature Limit exceeded.
2
2
PFAILSHUTDOWNINCOMPLETE
PFAILSHUTDOWNUNUSABLE
PFAILRECOVERYFAILURE
PFAIL-DIRTYPROGRAM
2
System failure detected.
Power Failure Detected. Machine was ungracefully shut down
prior to this power up.
Incomplete Power Failure Shutdown. The last shutdown
occurred during bonding and last wire was not successfully
bonded.
Corrupted Power Failure Data. The Power Failure Recovery
Data is corrupted making the recovery impossible.
PFAIL-BONDOFFFAILED
PFAILSHUTDOWNPROCESS-ERROR
PFAILSHUTDOWNFATAL-ERROR
SERVO_FAULT
3
PARM_TYPE_INV
ALID
EH_FAINT6_CPU_
GENERIC_ERR
PDTUNEXPECTEDNSOP
4
5
2
Power Failure Recovery Failure. An internal error occurred
during Power Failure Recovery.
3
Dirty Program Detected. Program residing in memory prior to
last shutdown was not saved to the disk. This makes Power
Failure Recovery impossible.
Bondoff Failure. The attempt to repair wire during Power Failure
Recovery failed.
Unrecoverable state. The last shutdown occurred while
machine was in PROCESS ERROR state. Thus, Power Failure
Recovery is impossible.
Unrecoverable state. The last shutdown occurred while
machine was in FATAL ERROR state. Thus, Power Failure
Recovery is impossible.
Servo error occurred. The machine entered the STANDBY
mode. Please exit the STANDBY mode to resume the normal
operation.
Parameter type is invalid.
2
2
2
5
3
FATAL ERROR - CPU FAULT INTERRUPT. The machine
stopped. Machine reboot is required.
PDT Error - BITS Error NSOP
Page - 269 - of 324
Jan 28, 2021 Rev 4.2
Kulicke & Soffa™
SECS/GEM Interface for K&S Ball Bonders
Bonder software version x-xx-x-473-series
ALID
(U2)
6050
6051
6052
6053
6054
6055
6056
6057
6058
6059
6060
6061
6062
6063
6064
6065
6066
6067
6068
6069
6070
6071
IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Alarms
ALTX
ALCD
Description
PDTUNEXPECTEDNSOL
PDTUNEXPECTEDSHTL
AUTO-ALIGNFIND-FAIL
AUTO-ALIGNLTOL-FAIL
AUTO-VLL-FINDFAIL
AUTO-VLL-WIDTHFAIL
AUTO-XHAIRERROR
AUTO-DRIFTERROR
AUTO-TOOLUSAGE-LIMITEXCEEDED
AUTOBONDHEADSAFETYVIOLATION
AUTOBONDHEADTABLE-VIOLATION
AUTO-AIR-OUTOF-LIMITS
AUTO-TEMP-OUTOF-AD-RANGE
AUTO-TEMP-OUTOF-AD-RANGECLXC
MHS_WORKHOLD
ER_NOT_EMPTY
MHS_PUL_CARRI
ER_ALREADY_PR
ESENT
FRL_WILL_REACH
_LIMIT_INDEX
PUL_HOME_NOT_
FOUND
IND_HOME_NOT_
FOUND
FRL_HOME_NOT_
FOUND
RRL_HOME_NOT_
FOUND
CI_HOME_NOT_F
OUND
3
PDT Error - BITS Error NSOL
3
PDT Error - BITS Error SHTL
3
ALIGN status - inadequate eye points found
3
ALIGN status - line distance outside tolerance
3
VLL Error - Failed to Locate Lead
3
VLL Error - lead width out of tolerance
3
Auto X Hair Correction Error
3
3
Machine is unable to perform Automatic X Hair correction.
Manual X Hair correction is needed
Tool Usage Limit Exceeded
2
Tool couldn't be positioned with out possible collision with MHS
2
Tool couldn't be positioned with out exceeding table limits
3
Missing air supply
3
Temperature Sensor Out of A-D range. Check Thermocouple
3
5
Temperature Sensor for Zone 4 Out of A-D range. Check Bond
Head Thermocouple. CLXC may not be used until this condition
is cleared
Workholder not empty. If material present, may damage
material/machine
Leadframe cannot be pulled in - one already present
5
Front rail will reach limit during device index
5
Puller's home not found
5
Indexer's home not found
5
Front rail's home not found
5
Rear rail's home not found
5
Clamp's home not found
5
Page - 270 - of 324
Jan 28, 2021 Rev 4.2
Kulicke & Soffa™
SECS/GEM Interface for K&S Ball Bonders
Bonder software version x-xx-x-473-series
ALID
(U2)
6072
6073
6074
6075
6076
6077
6078
6079
6080
6081
6082
6083
6084
6085
6086
6087
6088
6089
6090
6091
6092
6093
6094
6095
IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Alarms
ALTX
ALCD
Description
HB_HOME_NOT_F
OUND
GRP_HOME_NOT
_FOUND
IND_CARRIER_ED
GE_NOT_FOUND
IND_DEVICE_NOT
_FOUND
IND_BOND_TEAC
H_FAILURE
PUL_CARRIER_N
OT_PRESENT
PUL_CARRIER_E
DGE_NOT_FOUN
D
MHS_INIT_FAILUR
E
RAILS_LIMIT_DET
ECTED
FRL_LIMIT_DETE
CTED
RRL_LIMIT_DETE
CTED
Y_CORR_EXCEED
S_LIMIT
X_CORR_EXCEED
S_UPDATE_LIMIT
Y_CORR_EXCEED
S_UPDATE_LIMIT
RLS_INDEX_ERR
OR
MH_SLOT_SENSO
R_BLOCKED_NON
E_MAG
MH_SLOT_SENSO
R_BLOCKED_NON
E_MAG_O
MH_SLOT_SENSO
R_BLOCKED
MH_SLOT_SENSO
R_BLOCKED_O
MH_Y_SENSOR_F
AILURE
MH_Y_SENSOR_F
AILURE_O
MH_Z_SENSOR_F
AILURE
MH_Z_SENSOR_F
AILURE_O
RRL_WILL_REAC
H_LIMIT_INDEX
5
Heat block's home not found
5
Indexer gripper's home not found
5
Lead frame's X registration edge not found
5
Device's eye point not found
5
Teach bonding position failure
5
Empty input magazine slot
5
Lead frame's X registration edge not found
5
MHS initialization failed
4
Rail limit sensor was blocked
4
Front rail limit sensor was blocked
4
Rear rail limit sensor was blocked
4
Y correction requested exceeds limit
4
X correction exceeds update limit
4
Y correction exceeds update limit
5
Rail index motion error
5
Cannot perform requested operation since Input magazine
handler slot sensor is blocked
5
Cannot perform requested operation since Output magazine
handler slot sensor is blocked
5
5
Cannot perform initialization operation since Input magazine
handler slot sensor is blocked
Cannot perform initialization operation since Output magazine
handler slot sensor is blocked
Input Y motor: motion error or home sensor timeout
5
Output Y motor: motion error or home sensor timeout
5
Input Z motor: motion error or home sensor timeout
5
Output Z motor: motion error or home sensor timeout
5
Rear rail will reach limit during device index
5
Page - 271 - of 324
Jan 28, 2021 Rev 4.2
Kulicke & Soffa™
SECS/GEM Interface for K&S Ball Bonders
Bonder software version x-xx-x-473-series
ALID
(U2)
6096
6097
6098
6099
6100
6101
6102
6103
6104
6105
6106
6107
6108
6109
6110
6111
6112
6113
6115
6116
6117
6118
6119
6120
6121
IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Alarms
ALTX
ALCD
Description
MH_FAILED_STO
RE_MAG
MH_FAILED_STO
RE_MAG_O
MH_FAILED_GET_
MAG
MH_FAILED_GET_
MAG_O
MH_INPUT_TRAY_
EMPTY
MH_INPUT_TRAY_
EMPTY_O
MH_OUTPUT_TRA
Y_FULL
MH_OUTPUT_TRA
Y_FULL_O
MH_G_SENSOR_F
AILURE
MH_G_SENSOR_F
AILURE_O
MH_FAILED_OPE
RATION_CHESS
MH_FAILED_OPE
RATION_CHESS_
O
FRL_WILL_REACH
_LIMIT_CORR
RRL_WILL_REAC
H_LIMIT_CORR
FRL_LIMIT_REAC
HED_INDEX
MH_TRAY_NOT_D
ETECTED
MH_TRAY_NOT_D
ETECTED_O
MH_TRAY_DETEC
T_SENSOR_FAILU
RE
MH_GRIP_SENSO
RS_FAILED
MH_GRIP_SENSO
RS_FAILED_O
MH_GRIP_ACTIVE
_INVALID
MH_GRIP_ACTIVE
_INVALID_O
MH_TOUCH_ACTI
VE_INVALID
MH_TOUCH_ACTI
VE_INVALID_O
MH_STATE_BAD_
SENSORS_GRIP
5
Failed to unload magazine in Input magazine handler
3
Failed to unload magazine in Output magazine handler
5
Input mag handler: Failed to load mag (calibration)
5
Output mag handler: Failed to load mag (calibration)
5
Input magazine handler, Load tray is empty
5
Output magazine handler, Load tray is empty
5
Input magazine handler, tray full sensor detected
5
Output magazine handler, tray full sensor detected
5
Input G motor: motion error or home sensor timeout Sensor in
gripper not detected
Output G motor: motion error or home sensor timeout Sensor in
gripper not detected
Input magazine handler, Cannot correct the situation, please
chess to a safe location
Output magazine handler, Cannot correct the situation, please
chess to a safe location
5
5
5
3
Front rail reached limit during device index
3
Rear rail reached limit during device index
3
Front rail reached limit during device correction
5
Input magazine handler, tray not detected by sensor
5
Output magazine handler, tray not detected by sensor
5
Input magazine handler, unexpected tray sensor state
5
Input mag handler gripping sensor states not same
5
Output mag handler gripping sensor states not same
5
Input mag handler grip sensor blocked
5
Output mag handler grip sensor blocked
5
Input mag handler touch sensor blocked
5
Output mag handler touch sensor blocked
5
Input mag handler gripping sensors blocked
Page - 272 - of 324
Jan 28, 2021 Rev 4.2
Kulicke & Soffa™
SECS/GEM Interface for K&S Ball Bonders
Bonder software version x-xx-x-473-series
ALID
(U2)
6122
6123
6124
6125
6126
6127
6128
6129
6130
6131
6132
6133
6134
6135
6136
6137
6138
6139
6140
6141
6142
6143
6144
6145
6146
6147
IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Alarms
ALTX
ALCD
Description
MH_STATE_BAD_
SENSORS_GRIP_
O
MH_INVALID_MAG
_HEIGHT
MH_INVALID_MAG
_HEIGHT_O
MH_STORE_SENS
OR_ERROR
MH_STORE_SENS
OR_ERROR_O
MH_TRAY_ERRO
R_IN_LOAD
MH_TRAY_ERRO
R_IN_UNLOAD
MH_TRAY_ERRO
R_OUT_LOAD
MH_TRAY_ERRO
R_OUT_UNLOAD
MHS_IND_AXIS_LI
MIT_ERROR
MHS_IND_JAM_R
ELIEF_ERROR
RRL_LIMIT_REAC
HED_INDEX
FRL_LIMIT_REAC
HED_CORR
RRL_LIMIT_REAC
HED_CORR
FRL_LIMIT_REAC
HED_CYCLE
RRL_LIMIT_REAC
HED_CYCLE
FRL_WILL_REACH
_LIMIT_SETUP
RRL_WILL_REAC
H_LIMIT_SETUP
PUL_NOT_OUT_O
F_HOME
IND_NOT_OUT_O
F_HOME
FRL_NOT_OUT_O
F_HOME
RRL_NOT_OUT_O
F_HOME
CI_NOT_OUT_OF_
HOME
HB_NOT_OUT_OF
_HOME
GRP_NOT_OUT_O
F_HOME
IND_RECOVERY
5
Output mag handler gripping sensors blocked
5
Input mag handler: Failed to load mag (setup)
5
Output mag handler: Failed to load mag (setup)
5
5
Input mag handler store magazine error Tray Full or Tray Detect
sensor active
Output mag handler store magazine error Tray Full or Tray
Detect sensor active
A magazine was illegally place on the input mag's load tray or it
was illegally taken off
A magazine was illegally place on the Input Mag's unload tray
or it was illegally taken off
A magazine was illegally place on the Output Mag's load tray or
it was illegally taken off
A magazine was illegally place on the Output Mag's unload tray
or it was illegally taken off
Indexer Motion interrupted
5
Jam transducer decompression failure
4
Rear rail reached limit during device index
4
Front rail reached limit during device correction
4
Rear limit reached limit during device correction
4
Front rail reached limit during cycling
4
Rear rail reached limit during cycling
4
Front rail will reach limit during setup
4
Rear rail will reach limit during setup
5
Puller is not out of home
5
Indexer is not out of home
5
Front rail is not out of home
5
Rear rail is not out of home
5
Clamp is not out of home
5
Heat block is not out of home
5
Indexer gripper is not out of home
5
Index sequence aborted
5
5
5
5
5
Page - 273 - of 324
Jan 28, 2021 Rev 4.2
Kulicke & Soffa™
SECS/GEM Interface for K&S Ball Bonders
Bonder software version x-xx-x-473-series
ALID
(U2)
6148
6149
6150
6151
6152
6153
6154
6155
6156
6157
6158
6159
6160
6161
6162
6163
6164
6165
6166
6167
6168
6169
IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Alarms
ALTX
ALCD
Description
IND_REMOVE_CR
R
CORR_IFR_WITH_
PREBOND_CRR
RLS_CORRECT_E
RROR
WHL_HAS_DEVIC
E_CLAMPED
MH_INIT_CANNOT
_STORE_MAGAZI
NE
MH_CHESS_TO_S
AFE_LOCATION
MH_DROP_MAGA
ZINE
MH_MUST_ALSO_
HOME_Y_MOTOR
MH_MUST_ALSO_
HOME_Y_MOTOR
_O
MH_HOME_G_MU
ST_HOME_Y_MOT
OR
MH_HOME_G_MU
ST_HOME_Y_MOT
OR_O
MH_HOME_G_MU
ST_HOME_Z_MOT
OR
MH_HOME_G_MU
ST_HOME_Z_MOT
OR_O
MH_HOME_GRIPP
ER_DROP_MAG
MH_HOME_GRIPP
ER_DROP_MAG_
O
MH_INVALID_GRI
P_STATE
MH_INVALID_GRI
P_STATE_O
MH_INVALID_UNG
RIP_STATE
MH_INVALID_UNG
RIP_STATE_O
MH_TRAY_DETEC
TED
MH_TRAY_DETEC
TED_O
MH_GRIP_ACTIVE
_INVALID_ABORT
5
Remove leadframe from the rails
5
Correction will interfere with pre-bond leadframe
5
Rail correction motion error
5
There is a clamped device present and operation will release
this device
Cannot unload magazine so cannot properly complete the
initialization operation
5
5
Lost power fail data must chess to safe location
5
MH magazine will be dropped
5
Home operation on Input magazine handler will also Home the
Y motor since damage to the trays could result otherwise
Home operation on Output magazine handler will also home the
Y motor since damage to the trays could result otherwise
5
5
Homing the gripper on the Input magazine handler while in the
tray area could damage the trays
5
Homing the gripper on the Output magazine handler while in the
tray area could damage the trays
5
Homing the gripper motor on the Input magazine handler may
damage the handler so must first home the Z motor
5
Homing the gripper motor on the Output magazine handler may
damage the handler so must first home the Z motor.
5
Homing the gripper on the Input magazine handler will drop the
magazine
Homing the gripper on the Output magazine handler will drop
the magazine
5
5
5
5
5
5
5
5
Input magazine handler state says gripped yet touch and grip
sensor are not both active
Output magazine handler state says gripped yet touch and grip
sensor are not both active
Input magazine handler state says ungripped yet touch and/or
grip sensor are active
Output magazine handler state says ungripped yet touch and/or
grip sensor are active
Input magazine handler, tray detect sensor active at invalid
location, Invalid sensor condition
Output magazine handler, tray detect sensor active at invalid
location, Invalid sensor condition
Input mag handler grip sensor blocked
Page - 274 - of 324
Jan 28, 2021 Rev 4.2
Kulicke & Soffa™
SECS/GEM Interface for K&S Ball Bonders
Bonder software version x-xx-x-473-series
ALID
(U2)
6170
6171
6172
6173
6174
6175
6176
6179
6180
6181
6182
6183
6184
6185
6186
6187
6188
6189
6190
6191
6192
IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Alarms
ALTX
ALCD
Description
MH_GRIP_ACTIVE
_INVALID_ABORT
_O
MH_TOUCH_ACTI
VE_INVALID_ABO
RT
MH_TOUCH_ACTI
VE_INVALID_ABO
RT_O
MH_STATE_BAD_
SENSORS_GRIP_
ABORT
MH_STATE_BAD_
SENSORS_GRIP_
ABORT_O
MH_OP_SUSPEN
D
MH_OP_SUSPEN
D_O
MH_TEACH_TOO_
MUCH_ROTATION
MH_TEACH_OPER
ATION_FAILED
MH_CAL_SLOT_O
PERATION_FAILE
D
MH_CAL_TRAY_O
PERATION_FAILE
D
IND_THETA_EXTE
ND_FAILURE
MHS_JDC_CMD_F
AILURE
MHS_JDC_DIAG_F
AILURE
MHS_JDC_INIT_F
AILURE
PUL_Y_REGISTRA
TION_FAILURE
PUL_CARRIER_MI
SSING
PUL_Y_REGISTRA
TION_ACTIVE
MHS_INDEXER_C
ALIBRATION_UNS
UCCESSFUL
MHS_CLAMP_CAL
IBRATION_UNSUC
CESSFUL
MHS_RAILS_CALI
BRATION_UNSUC
CESSFUL
5
Output mag handler grip sensor blocked
5
Input mag handler touch sensor blocked
5
Output mag handler touch sensor blocked
5
Input magazine handler state reports ungripped, and sensors
report a magazine is gripped
5
Output magazine handler state reports ungripped, and sensors
report a magazine is gripped
5
Input mag handler: Operation Suspended
5
Output mag handler: Operation Suspended
5
Too much rotation found when teaching mag.
5
Teach operation failed
5
Calibrate slot operation failed
5
Calibrate tray operation failed
5
Theta bar not extended due to indexer's position
5
Jam Detect command failed
5
Jam Detect diagnostic failed - do calibration
5
Work holder JDC cross load failed
5
Lead frame's Y registration edge not found
5
leadframe is not present on the work holder
5
Y registration sensor is already blocked
5
indexer calibration terminated
5
clamp calibration terminated
5
rails calibration terminated
Page - 275 - of 324
Jan 28, 2021 Rev 4.2
Kulicke & Soffa™
SECS/GEM Interface for K&S Ball Bonders
Bonder software version x-xx-x-473-series
ALID
(U2)
6193
6194
6195
6196
6197
6198
6199
6200
6201
6202
6204
6205
6206
6207
6208
6209
6210
6211
6212
6213
6214
IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Alarms
ALTX
ALCD
Description
MHS_X_SENSOR_
CALIBRATION_UN
SUCCESSFUL
MHS_CAL_TUCKE
R_EJECT_OPERA
TION_FAILED
MHS_JAM_CALIB
RATION_UNSUCC
ESSFUL
MHS_IN_BCR_FAI
L
MHS_OUT_BCR_F
AIL
AUTO_INVALID_M
AG
PBI-UNIT-STOPERR
AUTO-LEAD-BPCERR
AUTO-USGIMPEDANCE-CALFAIL
AUTO-USGIMPEDANCE-OUTLIMIT
TEMPERATURE_A
UTO_TUNE_FAIL
AUTO-CU-COVERGAS-PRESSUREOUT-LIMIT
TABLE_LIMITS_U
NACCEPTABLE
AUTO-VLL-FMDETECTED
AUTOOVERLAPPEDDIES
AUTO-ALIGNREFDRIFT-FAIL
AUTO_BOND_CO
UNT_REACHING_
LIMIT
AUTO_BOND_CO
UNT_REACHING_
LIMIT_NOWAIT
PDTBONDHEIGHTERROR
ZTC-OUT-OFLIMITS
PBI-WIRE-STOPERR
5
Work holder X sensor calibration terminated
5
Indexer tucker eject calibration terminated
5
jam detect calibration terminated
4
MHS in BCR Fail
4
MHS out BCR Fail
5
Auto Invalid Mag
2
Out of tolerance detected during Post Bond Inspection
2
4
A bond proximity check failed due to two or more leads were
found to be too close.
Auto USG impedance calibration failed.
3
USG impedance is out of limit.
5
Auto tuning of the heat block temperature failed
2
Nitrogen gas flow out of tolerance
6
X or Y table limits are unacceptable
3
Auto VLL foreign material detected.
3
Auto Overlapped Dies
3
Auto Algin Redrift Fail
3
Auto Bond Count Reach Limit
3
Auto Bond Count Reaching Limit NO Wait
3
Bond Height Error
5
Out of limits in zone temperature control.
2
Out of tolerance detected during Post Bond Inspection by wire.
Page - 276 - of 324
Jan 28, 2021 Rev 4.2
Kulicke & Soffa™
SECS/GEM Interface for K&S Ball Bonders
Bonder software version x-xx-x-473-series
ALID
(U2)
6215
6216
6217
6218
6219
6220
6221
6222
6223
6224
6225
6226
6227
6228
6229
6230
6231
6232
6233
6234
6235
6236
6237
6238
6239
IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Alarms
ALTX
ALCD
Description
CAP_CLEAN_TAP
E_USAGE_EXCEE
D_LIMIT
EH-PDT-SMBALL
PDTUNEXPECTEDNSOP-TOL
PBI-REALIGNFAILURE
CAP_CLEANING_L
IMIT_EXCEEDED
BONDSITE_CHKS
UM_FAIL
REF_SYS_XHAIR_
OFFSET_FAIL
MH_WAIT_GET_M
AG
MH_WAIT_GET_M
AG_O
STRIP_ID_NOT_F
OUND
MH_WT_HOST_R
ETRY_XCEED
MH_WT_HOST_R
ETRY_XCEED_O
EH_SUB_VALIDAT
ION_TIMEOUT
MHS_IN_BCR_REJ
ECT_ERROR
MHS_OUT_BCR_R
EJECT_ERROR
EH_SUB_VALIDAT
ION_REJECTED
EH_EVENT_COUN
T_THRESHOLD_E
XCEEDED
AUTO_USG_LOCK
_FREQ_DRIFT
EH_EVENT_COUN
T_STOP_AUTO
PDT-MOTIONTIMEOUT
PDT-AWAITTIMEOUT
PDT-CALLBACKREGISTRATION
WARNING_EFO_N
OT_HAZARD
PDT-EFOINVALID-DATA
EH-PDT-BUMPLIFT
6
Cap Clean Tape Usage Exceed Limit
2
3
PDT Error Small Ball Detected
PDT Unexpected NSOP Top of Loop
2
PBI Realign Failure
3
Cap Cleaning Limit Exceeded
3
Bond Site check sum error
3
Ref Sys Xhair Offset Fail
3
Input MH Wait Get Mag
3
MH Wait Get Output Magazine
4
Strip ID Not Found
4
Input magazine validation timeout
4
Output magazine validation timeout
4
Substrate ID validation timeout
4
Input magazine is rejected by host
4
Output magazine is rejected by host
4
Substrate is rejected by host
7
Event Count Threshold Exceeded
4
USG Lock Frequency Drift
6
EH Event Count Stop Auto
5
PDT Motion Time out
5
PDT Await Time out
5
PDT Callback Registration
6
Warning EFO Not Hazard
4
PDT EFO Invalid Data
4
EH PDT Bump Lift
Page - 277 - of 324
Jan 28, 2021 Rev 4.2
Kulicke & Soffa™
SECS/GEM Interface for K&S Ball Bonders
Bonder software version x-xx-x-473-series
ALID
(U2)
6240
6241
6242
6243
6244
6245
6246
6247
6248
6249
6250
6251
6252
6253
6254
6255
6256
6257
6258
6259
6260
6261
6262
6263
6264
IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Alarms
ALTX
ALCD
Description
EFO-BOX-COMERROR
EFO-RESOURCENOT-AVAILABLE
PDT-NO-TIMERS
PDT-NO-FSDETECT
PDT-BITS-CALERROR
PDT-DIE-MISSING
PDTUNEXPECTEDLGTL
PDTUNEXPECTEDNSOP-BY-PRS
MANUALUNEXPECTEDNSOP
MANUALUNEXPECTEDNSOL
MANUALUNEXPECTEDSHTL
MANUALWIREFEEDERROR
MANUAL-EFOINVALID-DATA
EFO-CLEAN
MANUALUNEXPECTEDLGTL
CAP-UNCLOG
EH_AUTO_RECV_
REPLACE_BOFF_
PLATE
AUTO-USG-LOCKDRIFT
AUTO-EMS-LOW
AUTO-ALIGNFATAL
AUTO-ALIGNMOT-FAIL
AUTO-ALIGN-PRSFAIL
AUTO-ALIGN-VLLFAIL
AUTO-UPDATEAWAIT-TIMEOUT
AUTO-BAD-START
6
EFO Box Com Error
4
EFO Resource not Available
4
3
PDT NO Timers
PDT NO FS Detect
3
PDT BITS Cal Error
6
6
PDT DIE Missing
PDT Unexpected LGTL
6
Equipment Status Warning
6
Manual Unexcepted NSOP
6
Manual Unexcepted NSOL
6
Manual Unexcepted SHTL
6
Manual Wirefeed Error
6
Manual EFO Invalid Data
7
6
EFO Clean
Manual Unexcepted LGTL
6
7
Cap UNCLOG
EH Auto Recive Replace BOFF Plate
6
Auto USG Lock Drift
6
6
Auto EMS Low
Auto Align Fatal
6
Auto Align MOT Failure
6
Auto Align PRS Failure
6
Auto Align VLL Failure
5
Auto Update Await Time Out
6
Auto Bad Start
Page - 278 - of 324
Jan 28, 2021 Rev 4.2
Kulicke & Soffa™
SECS/GEM Interface for K&S Ball Bonders
Bonder software version x-xx-x-473-series
ALID
(U2)
6265
6266
6267
6268
6269
6270
6271
6272
6273
6274
6275
6276
6277
6278
6279
6280
6281
6282
6283
6284
IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Alarms
ALTX
ALCD
Description
AUTOREJECTEYESKIPPARMSEXCEEDED
AUTO-ZPROBESKIPPARMSEXCEEDED
AUTO-LARGEDRIFT-ERROR
FAILEDCAPILLARY-FIND
MLO-EXCESSCHG-STOP
BOFF-AREA-FULL
AUTO-NEARINGTOOL-USAGELIMIT
AUTOBONDHEADTABLEVIOLATIONNOWAIT
AUTO-CONF-BPCERR
AUTO-BITS-CFGXMATCH-SWDCHWAC
AUTO-BITS-CFGXMATCH-SWACHWDC
AUTO-PRE-BONDCHECK
MC_IDLE_TOO_L
ONG
AUTO-WIREUSAGETHRESHOLDEXCEEDED
AUTO-TOOLUSAGE-LIMITEXCEEDEDNOWAIT
AUTO-MHSCLAMP-OPEN
ZTC-AD-RANGEERROR
AUTO-TEMP-OUTOF-RANGEOPTICS
ZPROTECT-HIALARM
ZPROTECT-OPENSENSOR
7
Auto Reject Eye Skip Parameters Exceeded
7
Auto ZPROBE Skip Parameters Exceeded
6
Auto Large Drift Error
6
Failed Capillary Find
7
MLO Excess CHG Stop
7
7
BOFF Area Full
Auto Nearing Tool Usage Limit
7
Auto Bondhead Table Violation No Wait
4
Auto Configure BPC Error
4
Auto BITS Configure XMatch SWDC HWAC
4
Auto BITS Configure XMatch SWAC HWDC
7
Auto Prepare Bond Check
7
Machine Idle Too Long
7
Auto Wire Usage Threshold Exceeded
7
Auto Tool Usage Limit Exceeded No Wait
6
Auto MHS Clamp Open
5
ZTC AD Range Error
6
Auto Temp Out Of Range Optics
6
ZPROTECT HI Alarm
6
ZPROTECT Open Sensor
Page - 279 - of 324
Jan 28, 2021 Rev 4.2
Kulicke & Soffa™
SECS/GEM Interface for K&S Ball Bonders
Bonder software version x-xx-x-473-series
ALID
(U2)
6285
6286
6287
6288
6289
6290
6291
6292
6293
6294
6295
6296
6297
6298
6299
6300
6301
6302
6303
6304
6305
6306
6307
6308
6309
6310
IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Alarms
ALTX
ALCD
Description
AUTO-ALIGN-PADFAIL
AUTO-TEMPCTRL-COMM-FAIL
OPERATORERROR
AUTO-MATROX-EDRIVE-FULL
AUTO-EFO-LIMITEXCEEDED
AUTO-EFOSTART-CLEAN
AUTO_EFOPM_LI
MIT_EXCEEDED
TEST-ERROR
MHS_UNDEFINED
_CMD
MHS_DISABLED_
ACTIVE_CMD
MHS_UNAVAILAB
LE_CMD_RESOUR
CES
MHS_LOGIC_ERR
OR
MHS_ALREADY_A
CTIVE_CMD
MHS_MSG_QUEU
E_OVERFLOW
MHS_DYNAMIC_L
OAD_ERROR
MHS_CONFIRM_C
MD_RESOURCES
MHS_LOGIC_ERR
OR_NO_BLOCK
PUL_CARRIER_AL
READY_PRESENT
MH_LOGIC_ERRO
R
MH_SETUP_ERRO
R
MH_CREATE_ERR
OR
MH_SEND_ERRO
R
MH_RX_ERROR
MH_CHUTE_EMPT
Y
MH_CHUTE_EMPT
Y_O
MH_BAD_GRIPPE
R_SIZE
6
Auto Align Pad failure
6
Auto Temo CTRL COMM Failure
6
Operate Error
5
Auto matrox E Drive Full
6
Auto EFO Limit Exceeded
7
Auto EFO Start Clean
6
Auto EFOPM Limit exceeded
3
3
Test Error
MHS Undifined Command
3
MHS Disabled Active Command
3
MHS Unavailable Command Resources
3
MHS Logic Error
3
MHS Already Active Command
3
MHS Message Queue Overflow
3
MHS Dynamic Load Error
3
MHS Confirm Command Resources
3
MHS Logic Error No Block
7
PUL Carrier Already Present
3
MH Logic Error
3
MH Setup Error
3
MH Create Error
3
MH Send Error
3
7
MH RX Error
MH Chute Empty
7
MH Chute Empty O
6
MH Bad Gripper Size
Page - 280 - of 324
Jan 28, 2021 Rev 4.2
Kulicke & Soffa™
SECS/GEM Interface for K&S Ball Bonders
Bonder software version x-xx-x-473-series
ALID
(U2)
6311
6312
6313
6314
6315
6316
6317
6318
6319
6320
6321
6322
6323
6324
6325
6326
6327
6328
6329
6330
6331
6332
6333
6334
6335
6336
IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Alarms
ALTX
ALCD
Description
MH_BAD_GRIPPE
R_SIZE_O
MH_BAD_GRIPPE
R_CHANGE_O
MH_TRAY_DETEC
T_SENSOR_FAILU
RE_O
MH_MAG_IFR
MH_MAG_IFR_O
MH_PUSHER_NO
T_RETRACT
MH_PUSHER_NO
T_RETRACT_0
MH_PUSHER_NO
T_OUT
MH_PUSHER_NO
T_OUT_0
MH_MAG_IN_LOA
D_NEW
MH_MAG_OUT_L
OAD_NEW
MH_STANDBY_MA
G_NOT_READY
MH_STANDBY_MA
G_NOT_READY_O
MH_TRAY_FULL_
DETECT
MH_TRAY_FULL_
DETECT_O
MH_INVALID_SEN
SOR
MH_TEACH_OPER
ATION_WORKED
WHL_UNDEFINED
_CRR_LOCK_STS
WHL_UNDEFINED
_INDEX_TYPE
WHL_UNDEFINED
_INDEX_STS
WHL_UNDEFINED
_CORR_STS
WHL_UNDEFINED
_INDEX_CYCLE
WHL_UNDEFINED
_INDEXER_STATE
WHL_UNDEFINED
_PULLER_STATE
WHL_CANNOT_C
REATE_SEMAPHO
RE
WHL_CANNOT_O
PEN_CHANNEL
6
MH Bad Gripper Size O
6
MH Bad Gripper Change O
6
MH Tray Detect Sensor Failure O
6
6
6
MH Magazine IFR
MH Magazine IFR O
MH Pusher Not Retract
6
MH Pusher Not Retract O
6
MH Pusher Not Out
6
MH Pusher Not Out O
6
MH Magazine IN Load New
6
MH Magazine Out Load New
7
MH STANDBY Mag Not Ready
7
MH STANDBY Mag Not Ready O
6
MH Tray Full Detect
6
MH Tray Full Detect O
6
MH Invalid Sensor
7
MH Teach Operation Worked
7
WHL Undefined CRR Lock STS
4
WHL Undefined Index Type
4
WHL Undefined Index STS
4
WHL Undefined CORR STS
4
WHL Undefined Index Cycle
4
WHL Undefined Indexer State
4
WHL Undefined Puller State
3
WHL Cannot Create Semaphore
3
WHL cannot Open Channel
Page - 281 - of 324
Jan 28, 2021 Rev 4.2
Kulicke & Soffa™
SECS/GEM Interface for K&S Ball Bonders
Bonder software version x-xx-x-473-series
ALID
(U2)
6337
6338
6339
6340
6341
6342
6343
6344
6345
6346
6347
6348
6349
6350
6351
6352
6353
6354
6355
6356
6357
6358
6359
6360
IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Alarms
ALTX
ALCD
Description
WHL_UNDEFINED
_PULL_TYPE
WHL_WANTS_BO
NDHEAD_MOVED
WHL_WANTS_BO
NDHEAD_POSITIO
NED
MHS_CMD_TBL_S
IZE_ERROR
MHS_JDC_CMD_T
IMEOUT
PUSHER_KIT_JAM
PUSHER_KIT_SEN
SOR_FAILURE
SENSOR_MON_U
NSAFE
SENSOR_MON_U
NSAFE_WHEN_B
ONDING
MH_FAILED_GRIP
_MAG_O
PULLER_GRIPPE
R_SENSOR_FAILU
RE
RAILS_TARGET_P
OS_CLIPPED
MHS_NEED_CAL_
FOR_CIWIDTHCH
K_NO_DONE
EH_CAPILLARY_D
ETECTION_ERRO
R
EH_FAST_PACKA
GE_ALIGN_FAIL
IND_LOAD_SENS
OR_UNSAFE
RWH_INDEX_FAIL
URE
MHS_PARAMETE
R_ERROR
RWH_IM_CMD_FA
ILURE
RWH_IV_CMD_FAI
LURE
RWH_CB_CMD_F
AILURE
INDEX_GRP_SEN
SOR_FAILURE
EJECT_GRP_SEN
SOR_FAILURE
PUL_CARRIER_W
RONG_ORIENTATI
ON
4
WHL Undefined Pull Type
6
WHL Wants Bondhead Moved
6
WHL Wants Bondhead Positioned
3
MHS CMD TBL Size Error
3
MHS JDC CMD Timeout
6
6
Pusher Kit JAM
Pusher Kit Sensor Failure
6
Sensor MON Unsafe
6
Sensor MON unsafe When Bonding
6
MH Failed Grip Mag O
6
Puller Gripper Sensor Failure
6
Rails Target Pos Clipped
6
MHS Need Cal for CIWIDTHCHK No Done
6
EH Capillary Detection Error
3
Fast package alignment error report
6
IND Load Sensor Unsafe
6
RWH Index Failure
4
MHS Parameter Error
3
RWH JM CMD Failure
3
RWH IV CMD Failure
3
RWH CB CMD Failure
6
Index GRP Sensor Failure
6
Eject GRP Sensor Failure
4
PUL Carrier Wrong Orientation
Page - 282 - of 324
Jan 28, 2021 Rev 4.2
Kulicke & Soffa™
SECS/GEM Interface for K&S Ball Bonders
Bonder software version x-xx-x-473-series
ALID
(U2)
6361
6362
6363
6364
6365
6366
6367
6368
6369
6370
6371
6372
6373
6374
6375
6376
6377
6378
6379
6380
6381
6382
6383
6384
6385
6386
IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Alarms
ALTX
ALCD
Description
PUL_CARRIER_O
RIENTATION_EDG
E_NOT_FOUND
MHS_WHL_VERIFI
CATION_UNSUCC
ESSFUL
INDEX_THETA_BA
R_SENSOR_FAILU
RE
EJECT_THETA_BA
R_SENSOR_FAILU
RE
MHS_GRIP_POINT
_ERROR
MHS_GP_ERROR
_INDEX_ABORT
LOAD_FAILED
LOAD_INFO
LOAD_INTERNAL_
ERROR
LOADER_BUSY
AUTO_PARAM_LO
AD_FAILED
MISCT_PARAM_L
OAD_FAILED
LEADT_PARAM_L
OAD_FAILED
PADT_PARAM_LO
AD_FAILED
INV_AUTO_PRM_
DATA_PTR
AUTO_PRM_RES_
NOT_REL
AUTO_PRM_RES_
NOT_AVL
INV_TCH_PRM_D
ATA_PTR
MISCT_PRM_RES
_NOT_REL
MISCT_PRM_RES
_NOT_AVL
LEADT_PRM_RES
_NOT_REL
LEADT_PRM_RES
_NOT_AVL
PADT_PRM_RES_
NOT_REL
PADT_PRM_RES_
NOT_AVL
RESTORE_ERRO
R
BACKUP_ERROR
6
PUL Carrier Orientation Edge Not Found
6
MHS WHL Verification Unsuccessful
6
Index Theta Bar Sensor Failure
6
Eject Theta Bar Sensor Failure
6
MHS Grip Point Error
6
MHS GP Error Index Abort
6
7
6
Load failed
Load Info
Load Internal Error
6
4
Loader Busy
Auto Parameter Load Failure
4
MISCT Param Load Failure
4
LEADT Param Load Failure
4
PADT Param Load Failure
4
INV Auto PRM Data PTR
4
Auto PRM RES Not REL
4
Auto PRM RES Not AVL
4
INV TCH PRM DATA PTR
4
MISCT PRM RES Not REL
4
MISCT PRM RES Not AVL
4
LEADT PRM RES Not REL
4
LEADT PRM RES Not AVL
4
PADT PRM RES Not REL
4
PADT PRM RES Not AVL
6
Restore Error
6
Backup Error
Page - 283 - of 324
Jan 28, 2021 Rev 4.2
Kulicke & Soffa™
SECS/GEM Interface for K&S Ball Bonders
Bonder software version x-xx-x-473-series
ALID
(U2)
6387
6388
6389
6390
6391
6392
6393
6394
6395
6396
6397
6398
6399
6400
6401
6402
6403
6404
6405
6406
6407
6408
6409
IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Alarms
ALTX
ALCD
Description
SELECT_ERROR
MEMORY_ERROR
FILE_ERROR
CLEANUP_ERROR
BACKUP_LIST_FIL
E_INVALID
PP_HEAP_ALLOC
_FAILED
PP_HEAP_CREAT
E_FAILED
PP_HEAP_SIZE_I
NVALID
MON-Y-MOTOROVER-TEMP
MON-MOTORWARNING
MON-UPSRUNNING
MON-SENSORBUS-ERROR
MON-UPS-BADBATTERY
EH_MON_IDLE_CL
AMP_OPEN_TIME
OUT
EH_GRIPPER_SO
LENOID_OVER_T
EMP_FAIL
EH_STANDBY_SE
ND_MHS_COMMA
ND
EH_STANDBY_ER
ROR
POWER-FAILURE-REBOOTMACHINE
MOMENTARYPOWER-FAILURE
POWER-LOW-REBOOTMACHINE
MOMENTARYPOWER-LOW
POWEROVERTEMP-REBOOTMACHINE
MOMENTARYPOWEROVERTEMP
6
6
6
6
6
Select Error
Memory Error
File Error
Clean Up Error
Backup List File Invalid
6
PP Heap Alloc Failure
6
PP Heap Alloc Failure
6
PP Heap Size Invalid
6
MON Y Motor Over Temp
6
MON Motor Warning
6
MON UPS Running
6
MON Sensor Bus Error
6
MON UPS Bad Battery
7
EH MON Idle Clamp Open Time Out
6
EH Gripper Solenoid Over Temp Failure
6
EH Standby Send MHS Command
6
EH Standby Error
7
Power Failure Reboot Machine
6
Momentary Power Failure
6
Power Low Reboot Machine
6
Momentary Power Low
6
Power Overtemp Reboot Machine
6
Momentary Power Overtemp
Page - 284 - of 324
Jan 28, 2021 Rev 4.2
Kulicke & Soffa™
SECS/GEM Interface for K&S Ball Bonders
Bonder software version x-xx-x-473-series
ALID
(U2)
6410
6411
6412
6413
6414
6415
6416
6417
6418
6419
6420
6421
6422
6423
6424
6425
6426
6427
6428
6429
IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Alarms
ALTX
ALCD
Description
SYSTEMFAILURE-REBOOTMACHINE
MOMENTARYSYSTEM-FAILURE
ZCONTACT_FAILU
RE
ZPOSITION_ERRO
R
ZSEEK_RECOVERY
_ERROR
CPU2_Z_NEG_LIM
IT_UPDATE_ERR
OR
XPOSITION_ERRO
R
YPOSITION_ERRO
R
EH_Z_LIMIT_FIND
_ERROR
EH_BFC_MOTION
_ERROR
EH_BFC_NON_MO
TION_ERROR
EH_ZMAP_MOTIO
N_ERROR
EH_BITS_AGC_CA
L_NOT_DONE
EH_FS_BONDOFF
_VERIFY_FAIL
EH_WFEED_COM
PORT_OPER_ERR
OR
EH_WFEED_COM
MUNICATION_ER
ROR
TEMPERATURE_C
OMMUNICATION_
ERROR
EH_TEMP_INVALI
D_PARAMS
EH_TEMP_RESOU
RCE_ACQUIRE_E
RROR
EH_TEMP_INVALI
D_SYS_R_SELEC
TOR
6
System Failure Reboot Machine
6
Momentary System Failure
6
Z Contact Failure
6
Z Position Error
3
Z Seek Recovery Error
3
CPU2 Z NEG Limit Update Error
2
X Position Error
2
Y Position Error
6
EH Z Limit Find Error
2
EH BFC Motion Error
2
EH BFC NON Motion Error
2
EH ZMAP Motion Error
3
EH BITS AGC CAL Not Done
6
EH FS Bondoff Verify Failure
3
EH WFEED Comport Oper Error
6
EH WFEED Communication Error
6
Temperature Communication Error
4
EH Temp Invalid Parameters
3
EH Temp Resource Acquire Error
4
EH Temp Invalid SYS R Selector
Page - 285 - of 324
Jan 28, 2021 Rev 4.2
Kulicke & Soffa™
SECS/GEM Interface for K&S Ball Bonders
Bonder software version x-xx-x-473-series
ALID
(U2)
6430
6431
6432
6433
6434
6435
6436
6437
6438
6439
6440
6441
6442
6443
6444
6445
6446
6447
6448
6449
6450
6451
IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Alarms
ALTX
ALCD
Description
EH_TEMP_INVALI
D_SYS_G_SELEC
TOR
EH_TEMP_INVALI
D_ZONE_R_SELE
CTOR
EH_TEMP_INVALI
D_ZONE_EM_SEL
ECTOR
EH_TEMP_PID_RE
SET_VALUE_ERR
OR
EH_TEMP_OFFSE
T_VALUE_ERROR
EH_TEMP_ZONE_
EM_PARAM_ERR
OR
EH_TEMP_SERIAL
_WRITE_ERROR
EH_TEMP_SERIAL
_READ_ERROR
EH_TEMP_ERROR
_MSG_REPLY
EH_TEMP_READ_
NOT_READY
EH_TEMP_WRITE
_NOT_READY
EH_TEMP_IO_SEL
ECT_ERROR
EH_TEMP_WRITE
_PROTECTED_PA
RM
EH_TEMP_UNKNO
WN_ERROR
EH_TEMP_CHANG
ERATE_ERROR
EH_IDIAG_SYNCH
_ERROR
EH_IDIAG_ASYNC
H_ERROR
EH_IDIAG_TEMP_
ZONE_FAULT
EH_IDIAG_BITS_M
ODE_HW_SW_MIS
MATCH
EH_IDIAG_BITS_C
ROSSLOAD_ERR
OR
EH_BITS_FULL_A
GC_FAILED
EH_BITS_WF_DU
MP_FAILED
4
EH Temp Invalid SYS G Selector
4
EH Temp Invalid ZONE R Selector
4
EH Temp Invalid ZONE EM Selector
6
EH Temp PID Reset Value Error
4
EH Temp Offset Value Error
4
EH Temp ZONE EM Param Error
6
EH Temp Serial Write Error
6
EH Temp Serial Read Error
3
EH Temp Error MSG Reply
3
EH Temp Read Not Ready
3
EH Temp Write Not Ready
6
EH Temp IO Select Error
4
EH Temp Write Protected Parm
5
EH Temp Unknown Error
2
EH Temp Changerate Error
3
EH Idiag Synch Error
3
5
EH Idiag Asynch Error
EH Idiag Temp Zone Fault
EH Idiag Temp Zone Fault
6
EH Idiag BITS Mode HW SW Mismatch
3
EH Idiag BITS Crossload Error
3
EH BITS Full AGC Failed
7
EH BITS WF DUMP Failed
Page - 286 - of 324
Jan 28, 2021 Rev 4.2
Kulicke & Soffa™
SECS/GEM Interface for K&S Ball Bonders
Bonder software version x-xx-x-473-series
ALID
(U2)
6452
6453
6454
6455
6456
6457
6458
6459
6460
6461
6462
6463
6464
6465
6466
6467
6468
6469
6470
6471
6472
6473
6474
6475
6476
6477
6478
IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Alarms
ALTX
ALCD
Description
EH_BITS_WF_LO
G_FAILED
EH_IDIAG_EEPRO
M_ERROR
EH_IDIAG_INVALI
D_TABLE_CONFIG
TAR_ERROR
TAR_WARNING
FLOPPY_WRITE_
PROTECTED
FLOPPY_INSERT_
ERROR
DEVICE_READY_
ERROR
DISK_FULL_ERRO
R
INSERT_NEXT_DI
SK
CALIBRATION_DA
TA_ERROR
INVALID
MISSING_MARKE
RS
CRC_OR_TIME_IN
VALID
CRC_STRING_LE
NGTH_INVALID
TIME_STRING_LE
NGTH_INVALID
EH_BONDER_CO
NFIG_ERROR
EH_FAINT6_CPU_
SPURIOUS_INT
EH_PCI_BRIDGE_
FAILURE
EH_SERDES_BUS
_ERROR
EH_CHESS_IN_US
E
EH_ILLEGAL_CHE
SS_RELEASE
EH_ILLEGAL_CHE
SS_NAME
NVR_MAC_ADDR_
CORRUPTION
NVR_PROT_MEM_
CORRUPTION
NVR_GENERAL_M
EM_CORRUPTION
EH-BOOT-PARMSAVE-ERR
7
EH BITS WF Log Failed
3
EH Idiag Eeprom Error
4
EH Idiag Invalid Table Configure
8
8
3
Tar Error
Tar Warning
Floppy Write Protected
3
Floppy Insert Error
6
Device Ready Error
6
Disk Full Error
7
Insert Next Disk
3
Calibration Data Error
6
6
Invalid
Missing Markers
4
CRC Or Time Invalid
4
CRC String Length Invalid
4
Time String Length Invalid
4
EH Bonder Config Error
5
EH Faint6 CPU Spurious INT
5
EH PCI Bride Failure
5
EH Serdes Bus Error
7
EH Chess IN Use
7
EH Illegal Chess Release
4
EH Illegal Chess Name
5
NVR MAC ADDR Corruption
5
NVR PROT MEM Corruption
5
NVR General MEM Corruption
4
EH Boot Parm Save Error
Page - 287 - of 324
Jan 28, 2021 Rev 4.2
Kulicke & Soffa™
SECS/GEM Interface for K&S Ball Bonders
Bonder software version x-xx-x-473-series
ALID
(U2)
6479
6480
6481
6482
6483
6484
6485
6486
6487
6488
6489
6490
6491
6492
6493
6494
6495
6496
6497
6498
6499
6500
6501
6502
6503
IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Alarms
ALTX
ALCD
Description
EH-BOOT-PARMSET-ERR
EH-BOOT-PARMRESTORE-ERR
EH-INSTALLKERNEL-COPYERR
EH-INSTALLPROCESS-ERR
VDKError_kUnkno
wnThreadType
VDKError_kUnkno
wnThread
VDKError_kThread
CreationFailure
VDKError_kUnkno
wnSemaphore
VDKError_kUnkno
wnEventBit
VDKError_kUnkno
wnEvent
VDKError_kInvalidP
riority
VDKError_kInvalid
Delay
VDKError_kSemap
horeTimeout
VDKError_kEventTi
meout
VDKError_kBlockInI
nvalidRegion
VDKError_kDbgPos
sibleBlockInRegion
VDKError_kInvalidP
eriod
VDKError_kAlready
Periodic
VDKError_kNonperi
odicSemaphore
VDKError_kDbgPo
pUnderflow
VDKError_kBadIOI
D
VDKError_kBadDev
iceDescriptor
VDKError_kOpenF
ailure
VDKError_kCloseF
ailure
VDKError_kReadFa
ilure
4
EH Boot Parm Set Error
4
EH Boot Parm Restore Error
5
EH Install Kernel Copy Error
5
EH Install Process Error
6
VDKError kUnknownThreadType
6
VDKError kUnknownThead
6
VDKError kUnknownCreation Failure
6
VDKError kUnknownSemaphore
6
VDKError kUnknownEventBit
6
VDKError kUnknownEvent
6
VDKError kInvalidPriority
6
VDKError kInvalidDelay
6
VDKError kSemaphore Timeout
6
VDKError kEventTimeOut
6
VDKError kBlockInInvalidRegion
6
VDKError kDbgPossibleBlockInRegion
6
VDkError kInvalidPeriod
6
VDKError kAlreadyPeriodic
6
VDKError kNenperiodicSemaphore
6
VDKError kDbgPopUnderFlow
6
VDKError kBadIOID
6
VDKError kBadDeviceDescriptor
6
VDKError kOpenFailure
6
VDKError kCloseFailure
6
VDKError kReadFailure
Page - 288 - of 324
Jan 28, 2021 Rev 4.2
Kulicke & Soffa™
SECS/GEM Interface for K&S Ball Bonders
Bonder software version x-xx-x-473-series
ALID
(U2)
6504
6505
6506
6507
6508
6509
6510
6511
6512
6513
6514
6515
6516
6517
6518
6519
6520
6521
6522
6523
6524
6525
6526
6527
6528
IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Alarms
ALTX
ALCD
Description
VDKError_kWriteFa
ilure
VDKError_kIOCtlFa
ilure
VDKError_kInvalid
DeviceFlag
VDKError_kDevice
Timeout
VDKError_kDevice
FlagCreationFailure
VDKError_kMaxCo
untExceeded
VDKError_kSemap
horeCreationFailure
VDKError_kSemap
horeDestructionFail
ure
VDKError_kPoolCr
eationFailure
VDKError_kInvalidB
lockPointer
VDKError_kInvalidP
oolParms
VDKError_kInvalidP
oolID
VDKError_kErrorPo
olNotEmpty
VDKError_kErrorM
allocBlock
VDKError_kMessag
eCreationFailure
VDKError_kInvalid
MessageID
VDKError_kInvalid
MessageOwner
VDKError_kInvalid
MessageChannel
VDKError_kMessag
eTimeout
VDKError_kMessag
eInQueue
TCPError_ENOBU
FS
TCPError_ETIMED
OUT
TCPError_EISCON
N
TCPError_EOPNO
TSUPP
TCPError_ECONN
ABORTED
6
VDKError kWriteFailure
6
VDKError kIOCtlFailure
6
VDKError kInvalidDeviceFlag
6
VDKError kDevice TimeOut
6
VDKError kDevice Flag Creation Failure
6
VDKError kMaxCountExceeded
6
VDKError kSemaphoreCreationFailure
6
VDKError kSemaphoreDestructionFailure
6
VDKError kPoolCreationFailure
6
VDKError kInvalidBlockPointer
6
VDKError kInvalidPoolParms
6
VDKError kInvalidPoolID
6
VDKError kErrorPoolNotEmpty
6
VDKError kErrorMallocBlock
6
VDKError kMessageCreationFailure
6
VDKError kInvalidMessageID
6
VDKError kInvalidMessageOwner
6
VDKError kInvalidMessageChannel
6
VDKError kMessageTimeout
6
VDKError kMessageInQueue
6
TCPError ENOBUFS
6
TCPError ETIMEDOUT
6
TCPError EISCONN
6
TCPError EOPNOTSUPP
6
TCPError ECONNABORTED
Page - 289 - of 324
Jan 28, 2021 Rev 4.2
Kulicke & Soffa™
SECS/GEM Interface for K&S Ball Bonders
Bonder software version x-xx-x-473-series
ALID
(U2)
6529
6530
6531
6532
6533
6534
6535
6536
6537
6538
6539
6540
6541
6542
6543
6544
6545
6546
6547
6548
6549
6550
6551
6552
6553
6554
IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Alarms
ALTX
ALCD
Description
TCPError_EWOUL
DBLOCK
TCPError_ECONN
REFUSED
TCPError_ECONN
RESET
TCPError_ENOTC
ONN
TCPError_EALREA
DY
TCPError_EINVAL
TCPError_EMSGSI
ZE
TCPError_EPIPE
TCPError_EDESTA
DDRREQ
TCPError_ESHUTD
OWN
TCPError_ENOPR
OTOOPT
TCPError_EHAVE
OOB
TCPError_ENOME
M
TCPError_EADDR
NOTAVAIL
TCPError_EADDRI
NUSE
TCPError_EAFNOS
UPPORT
TCPError_EINPRO
GRESS
TCPError_ELOWE
R
TCPError_KN_EBA
DF
TCPError_EIEIO
PBI_BALL_RETEA
CH_REQUIRED
EH_EJECT_MAG_
FLASH
O_MAG_EJECT_T
HRESHOLD_WAR
NING_HEADER
INV_POWERSAVE
_PRM_DATA_PTR
PAD-FOR-PBINOT-FOUND
BALL-EXPECTOUT-OF-PAD
6
TCPError EWOULDBLOCK
6
TCPError ECONNREFUSED
6
TCPError ECONNRESET
6
TCPError ENOTCONN
6
TCPError EALREADY
6
6
TCPError EINVAL
TCPError EMSGSIZE
6
6
TCPError EPIPE
TCPError EDESTADDRREQ
6
TCPError ESHUTDOWN
6
TCPError ENOPROTOOPT
6
TCPError EHAVEOOB
6
TCPError ENOMEM
6
TCPError EADDRNOTAVAIL
6
TCPError EADDRINUSE
6
TCPError EAFNOSUPPORT
6
TCPError EINPROGRESS
6
TCPError ELOWER
6
TCPError KN_EBADF
6
7
TCPError EIEIO
PBI Ball Reteach Required
7
EH Eject Mag Flash
6
Output Mag Eject Threshold Warning Header
4
INV Powersave PRM Data PTR
7
Pad For PBI Not Found
7
Ball Expect Out Of Pad
Page - 290 - of 324
Jan 28, 2021 Rev 4.2
Kulicke & Soffa™
SECS/GEM Interface for K&S Ball Bonders
Bonder software version x-xx-x-473-series
ALID
(U2)
6555
6556
6557
6558
6559
6560
6561
6562
6563
6564
6565
6566
6567
6568
6569
6570
6571
6572
6573
6574
6575
6576
IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Alarms
ALTX
ALCD
Description
EH_AUTO_CONSE
CUTIVE_FALSE_P
RS_NSOP
AUTO_XHAIR_MA
P_INACTIVE
BHLIFTER_AIR_A
UTO
BHLIFTER_AIR_M
STOP
EH_INIT_FOCUS_
MOTOR_STEPPE
R_FAILED
EH_FATAL_IDX_N
OT_FOUND
IND_NO_CLAMP_
VACUUM_CONT
IND_CLAMP_VAC
UUM_OFF_FAIL
RAIL_LIMIT_AT_B
ONDSITE
RAIL_LIMIT_OUTS
IDE_BONDSITE
AUTO-WIREUSAGE-EXPIRY
EH-INSTALL-USBCOPY-ERROR
RWH_PN_CMD_F
AILURE
MHS_INDEXER_E
XCEED_WHL_LIMI
T
IMH_UNLOAD_FAI
L
OMH_UNLOAD_FA
IL
MH_WAIT_STORE
_MAG
MH_WAIT_STORE
_MAG_O
EJECT_INPUT_MA
GAZINE_NOT_EM
PTY
MH_LOAD_MAG_P
USHER_PUSH_FA
IL
MH_LOAD_MAG_P
USHER_PUSH_FA
IL_O
MH_UNLOAD_MA
G_PUSHER_PUSH
_FAIL
4
EH Auto Consecutive False PRS NSOP
6
Auto Xhair Map Inactive
6
BHLIFTER AIR Auto
6
BHLIFTER AIR Mstop
6
EH INIT Focus Motor Stepper Failed
7
EH Fatal IDX Not Found
6
IND No Clamp Vacuum Cont
3
IND Clamp Vacuum Off Failure
2
Rail Limit At bondsite
2
Rail Limit Outside Bondsite
7
Auto Wire Usage Expiry
3
EH Install USB Copy Error
4
RWH PNC MD Failure
2
MHS Indexer Exceed WHL Limit
7
IMH Unload Failure
7
OMH Unload Failure
7
MH Wait Store Magazine
7
MH Wait Store Output Magazine
7
Eject Input Magazine Not Empty
3
MH Load MAG Pusher Push Failure
3
MH Load MAG Pusher Push Failure O
3
MH Unload MAG Pusher Push Failure
Page - 291 - of 324
Jan 28, 2021 Rev 4.2
Kulicke & Soffa™
SECS/GEM Interface for K&S Ball Bonders
Bonder software version x-xx-x-473-series
ALID
(U2)
6577
6578
6579
6580
6581
6582
6583
6584
6585
6586
6587
6588
6589
6590
6591
6592
6593
6594
6595
6596
6597
6598
6599
IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Alarms
ALTX
ALCD
Description
MH_UNLOAD_MA
G_PUSHER_PUSH
_FAIL_O
MH_LOAD_MAG_P
USHER_RETRACT
_FAIL
MH_LOAD_MAG_P
USHER_RETRACT
_FAIL_O
MH_UNLOAD_MA
G_PUSHER_RETR
ACT_FAIL
MH_UNLOAD_MA
G_PUSHER_RETR
ACT_FAIL_O
AUTO-LOCATORFIND-FAIL
STRIP_MAP_DL_T
IMEOUT
STRIP_MAP_DL_F
AIL
STRIP_MAP_INVA
LID_SIZE
MHS_GRIP_THET
A_BIAS_FAIL
EH-USB-PWSMATROX-DROP
STRIP_MAP_INVA
LID_ORG_LOC
PARAM_RULE_ER
R
EH_GUIDE_SENS
OR_NOT_SAFE
EH_GUIDE_SENS
OR_NOT_SAFE_O
NKG_DONGLE_C
HECK_ERROR
STRIP_MAP_HOS
T_REPLY_HALT
RLS_UNBIAS_FAIL
ED
MON-UPS-LOWBATTERY
PROCESS-BP-HIT
AUTO-DRPCHECK-FAIL
EH_AUTO_TEMP_
OVER_HI_LIMIT_LI
NK
EH_AUTO_TEMP_
UNDER_LOW_LIMI
T_LINK
3
MH Unload MAG Pusher Push Failure O
3
MH Load Mag Pusher Retract Failure
3
MH Load Mag Pusher Retract Failure O
3
MH Unload Mag Pusher Retract Failure
3
MH Unload Mag Pusher Retract Failure O
3
Auto Locator Find Failure
3
Strip Map DL Timeout
3
Strip Map DL Failure
4
Strip Map Invalid Size
2
MHS Grip Theta Bias Failure
6
EH USB PWS Matrox Drop
4
Strip Map Invalid ORG LOC
4
Param Rule Error
2
EH Guide Sensor Not Safe
2
EH Guide Sensor Not Safe O
6
NKG Dongle Check Error
3
Strip Map Host Reply Halt
2
RLS UNBIAS Failure
6
MON UPS Low Battery
7
3
Process BP HIT
Auto DRP Check Failure
2
EH Auto Temp Over HI Limit Link
2
EH Auto Temp Under Low Limit Link
Page - 292 - of 324
Jan 28, 2021 Rev 4.2
Kulicke & Soffa™
SECS/GEM Interface for K&S Ball Bonders
Bonder software version x-xx-x-473-series
ALID
(U2)
6600
6601
6602
6603
6604
6605
6606
6607
6608
6609
6610
6611
6612
6613
6614
6615
6616
6617
6618
6619
6620
6621
6622
IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Alarms
ALTX
ALCD
Description
EH_AUTO_TEMP_
OVER_HI_LIMIT_O
PTICS
EH_AUTO_TEMP_
UNDER_LOW_LIMI
T_OPTICS
STRIP_MAP_HOS
T_REPLY_ERROR
EH_SUB_VALIDAT
ION_FAILED
CAP_CLEANING_
REACHING_LIMIT
EH_DISK_SPACE_
FULL
EH_DISK_SPACE_
NOT_FULL
EH_TEMP_OVER_
MAX_LIMIT
I2C_BUS_ERROR
PDT-PULLTSTINIT-ERR
CAL_XHAIR_MAP_
UNSUCCESSFUL
AUTO_COVER_GA
S_BACK_PRESSU
RE_HIGH
AUTO_COVER_GA
S_BACK_PRESSU
RE_LOW
PDTUNEXPECTEDNSOP-TIP2
EH-PDT-LGBALL
EH_HB_HIT_RAIL_
LIMIT_SWITCH
EH_BALL_TAIL_IN
VALIDATION
EH_STRIP_MAP_I
NVALID
EH_NFS_MOUNT_
FAIL_ERROR
EH_NSOL_AUTO_
REBOND_ATTEMP
TED
EH_NSOL_AUTO_
REBOND_FAILED
PUSHER_KIT_RET
RACT_FAILURE
EH_UNKNOWN_C
ELL_VERIFICATIO
N
2
EH Auto Temp Over HI Limit Optics
2
EH Auto Temp Under Low Limit Optics
3
Strip Map Host Reply Error
3
EH SUB Validation Failed
7
Cap Cleaning Reaching Limit
7
EH Disk Space Full
7
EH Disk Space Not Full
2
EH Temp Over Max Limit
6
3
I2C BUS Error
Pull Test initialization error
6
Cal Xhair map unsuccessful
6
Digital cover gas back pressure too high
6
Digital cover gas back pressure too low
3
Unexpected NSOP TIP2
2
2
PDT Large Ball
Heatblock hit rail limit switch
6
The ball or tail is invalidate
3
Strip map is invalid
6
NFS mount failed
6
NSOL Auto rebond attempted
6
NSOL Auto rebond failed
3
Error when pusher kit encounter error during retract
3
Unknown cell found(strip map only)
Page - 293 - of 324
Jan 28, 2021 Rev 4.2
Kulicke & Soffa™
SECS/GEM Interface for K&S Ball Bonders
Bonder software version x-xx-x-473-series
ALID
(U2)
6623
6624
6625
6626
6627
6628
6629
6630
6631
6632
6633
6634
6635
6636
6637
6638
6639
6640
6642
6643
IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Alarms
ALTX
ALCD
Description
AUTO-ALIGNFIND-FAILPARTIALBONDED-DEV
WIRE_CLAMP_PM
_LIMIT_EXCEEDE
D
EH_SAFETY_COV
ER_KIT_FAILURE
FLUID_RATE_LIMI
T_EXCEEDED
EH_PRH_VACUU
M_ON_FAIL
EH_RAILS_HOME
_SEEK_FAIL
EH_AIR_BLOWER
_OUTOF_LIMIT_W
_CONT
EH_AIR_BLOWER
_OUTOF_LIMIT
EH_ORIENT_EYE_
POINT_NOT_FOU
ND
EH_PERIODIC_EF
O_HEIGH_CHECK
_FAIL
EH_PERIODIC_EF
O_HEIGH_CHECK
_OUT_OF_LIMIT
CE_SOS_EVENT
EH_MHS_OHT_EX
EC_SEQ_ERR
EH_INPUT_MAG_
EJECT_INHIBITED
EH_OUTPUT_MAG
_EJECT_INHIBITE
D
EH_INPUT_MAG_
EJECT_HOST_VA
LIDATION_TIMEO
UT
EH_OUTPUT_MAG
_EJECT_HOST_V
ALIDATION_TIME
OUT
EH_WEDGE_VALI
DATION_CHECK_
FAIL
EH_SUBSTRATE_
MAP_PARSE_FAIL
CMP_COVER_HO
ME_NOT_FOUND
3
ALIGN status - inadequate eye points found #FEA3601
6
WIRE CLAMP PM LIMIT EXCEEDED
2
Safety Cover is open
6
ALID for fluid rate out of limit
3
Preheat Vacuum is not present
0
Rails Home Seek Fail
6
Air Blower Flow Rate Out Of Limit
6
Air Blower Flow Rate Out Of Limit
5
Search Orientation eye point failded
6
Periodic EFO height calibration fails
6
Periodic EFO height calibration out of limit
7
6
Alarm for SOS event
OHT Sequence Failure
6
Host disallow input mag ejection
6
Host disallow output mag ejection
6
Host does not reply input mag eject request within timeout
6
Host does not reply output mag eject request within timeout
6
Event of wedge validation checking fail
5
Parse Substrate Map Failed
6
Clamp cover home not found
Page - 294 - of 324
Jan 28, 2021 Rev 4.2
Kulicke & Soffa™
SECS/GEM Interface for K&S Ball Bonders
Bonder software version x-xx-x-473-series
ALID
(U2)
6644
6645
6646
6647
6648
6649
6650
6651
6652
6653
6654
6655
6656
6657
6658
6659
6660
6661
6662
6663
6664
6665
IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Alarms
ALTX
ALCD
Description
CMP_COVER_NO
T_OUT_OF_HOME
EH_HB_SECURE_
VACUUM_FAIL
EH_GCK_GAS_LO
W
EH_GCK_GAS_LO
W_IN_BONDING
EH_MAG_MOTION
_INTERRUPT
PUSHER_KIT_HO
ME_SENSOR_ER
ROR
EH_FOCUS_ADJ_
OUT_OF_LIMIT
PDTRPMOUTLIERERROR
EH_CNG_BOND_C
OUNTERS_EXCEE
DED
EH_CNG_BOND_C
OUNTERS_STOP_
AUTO
EH_FAINT6_GUI_
ERR
EH_REALTIME_RP
M_ERROR
EH_CLXC_BASE_
TEMP_THRESHOL
D_EXCEEDED
EH_MH_CHUTE_C
LAMP_FAILED
EH_MH_CHUTE_C
LAMP_FAILED_O
STRIP_ID_NOT_F
OUND_IN_LOCAL_
SERVER
PDT-DIE-HEIGHTOVER-LIMIT
EH_BATTERY_ST
S_SETTING_MISM
ATCH_ERROR
AUTO_CALIBRATI
ON_NEAR_EXPIR
ATION
AUTO_CALIBRATI
ON_EXPIRED
AUTO_CALIBRATI
ON_EXPIRED_ST
OP_INJECT
MDS_FAULT_DET
ECTED
6
Clamp cover is not out of home
6
Heat block secure vacuum not detected error
6
Tunnel gas low
6
Workholder Cover Gas Low During Bonding
6
Magazine motion is interrupted
2
Alarm: Pusher Kit home sensor has some error
3
Event #2378 Focus adjustment out of limit
3
Bonding stopped due to RPM single outlier error
7
Configured bond counter limit exceed
7
Configured bond counter limit exceed and stop auto
3
GUI Task Exception. Machine reboot is required
3
Realtime RPM error alarm
3
CLXC base temperature threshold exceeded error
6
Input chute clamp failed
6
Output chute clamp failed
4
strip ID not found in local server
3
PDT DIE Height Over Limit
6
Battery installation status does not match to battery setting in
subsystem selection
7
A machine calibration is near expiration.
7
A machine calibration has expired.
3
A machine calibration has expired and Strip Inject will be
disabled until it is performed.
8
Machine Data Collection Fault
Page - 295 - of 324
Jan 28, 2021 Rev 4.2
Kulicke & Soffa™
SECS/GEM Interface for K&S Ball Bonders
Bonder software version x-xx-x-473-series
ALID
(U2)
6666
6667
6668
6669
6670
6671
6672
6673
6675
6676
6677
6678
6679
6680
6681
6682
6683
6684
6685
6686
IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Alarms
ALTX
ALCD
Description
MH_BUFFER_RAIL
_NOT_EMPTY
MH_BUFFER_RAIL
_NOT_EMPTY_O
MH_INDEXER_RAI
L_NOT_EMPTY
MH_INDEXER_RAI
L_NOT_EMPTY_O
MH_BUFFER_RAIL
_CRR_NOT_READ
Y
MH_BUFFER_RAIL
_CRR_NOT_READ
Y_O
MH_INDEXER_RAI
L_CRR_NOT_REA
DY
MH_INDEXER_RAI
L_CRR_NOT_REA
DY_O
EH_COMM_DOWN
_BEFORE_UPLOA
D_STRIP_MAP
PDT_UNEXPECTE
D_NSOP_MISSING
_BOND
EH_STITCH_LIFT_
DETECTED
ACCESS_VIOLATI
ON_INPUT_LOAD
ACCESS_VIOLATI
ON_OUTPUT_LOA
D
PDTUNEXPECTEDSTITCH-LIFT
PDTUNEXPECTEDSTITCH-BREAK
PDTUNEXPECTEDSTITCH-LIFTBREAK
MDS_DATA_PURG
E_EVENT
EH_INVALID_STRI
P_MAP
KNS_CONNECT_E
RROR
EH_LAST_WIRE_N
SOL_REBOND_BE
F_SKIP_DEV
6
Loader’s buffer rail is not empty
6
Unloader’s buffer rail is not empty
6
Loader’s indexer rail is not empty
6
Unloader’s indexer rail is not empty
6
On loader’s buffer rail, carrier is not placed properly
6
On unloader’s buffer rail, carrier is not placed properly
6
On loader’s indexer rail, carrier is not placed properly
6
On unloader’s indexer rail, carrier is not placed properly
4
ALID for the event error: comm down before upload strip map
3
A missing bond has detected by bond monitor
3
Lifted stitch bond is detected by Stitch Lift Detection Feature
6
Input mag is placed by operator manually on load tray under
Auto access mode
Output mag is placed by operator manually on load tray under
Auto access mode
6
3
PDT Stitch Lift error
3
PDT Stitch Break error
3
PDT Stitch Lift/Break error
8
User warning before purging machine data
3
Alarm ID for EH_INVALID_STRIP_MAP
8
KNS Connect Error
3
Last Wire NSOL Rebond warning before auto skip device.
Page - 296 - of 324
Jan 28, 2021 Rev 4.2
Kulicke & Soffa™
SECS/GEM Interface for K&S Ball Bonders
Bonder software version x-xx-x-473-series
ALID
(U2)
6687
6688
6689
6690
6691
6692
6693
6694
6695
6696
6697
6698
6699
6700
6701
6702
6703
6704
6705
6706
6707
IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Alarms
ALTX
ALCD
Description
EH_AUTO_LHM_M
AX_LOOP_HT_EX
CEED_WARN_LIMI
T
EH_AUTO_LHM_M
AX_LOOP_HT_EX
CEED_ERR_LIMIT
EH_AUTO_LHM_E
DGE_HEIGHT_EX
CEED_WARN_LIMI
T
EH_AUTO_LHM_E
DGE_HEIGHT_EX
CEED_ERR_LIMIT
EH_AUTO_LHM_R
ESULT_VALIDATI
ON_TIMEOUT
EH_AUTO_LHM_R
ESULT_VALIDATI
ON_FAILED
EH_AUTO_LHM_R
ESULT_VALIDATI
ON_REJECTED
MH_MAG_SEPAR
ATION_ERR
MH_MAG_SEPAR
ATION_ERR_O
MH_PLATFORM_N
OT_EMPTY
MH_PLATFORM_N
OT_EMPTY_O
MH_FORK_NOT_E
MPTY
MH_FORK_NOT_E
MPTY_O
MH_PLATFORM_C
RR_NOT_READY
MH_PLATFORM_C
RR_NOT_READY_
O
MH_FOKR_CRR_N
OT_READY
MH_FOKR_CRR_N
OT_READY_O
LOADER_BENCH_
SEQ_ERROR
EH_SAFETY_INIT_
FAILED
EH_NSOL_REBON
D_BEF_SKIP_DEV
_FAILED
AIR_OUT_OF_TOL
ERANCE
3
Maximum loop height exceeds warning limit
3
Maximum loop height exceeds error limit
3
Edge height exceeds warning limit
3
Edge height exceeds error limit
3
LHM: Result validation timeout
3
LHM: Result validation failed
3
LHM: Result rejected by host
5
6
Input magazine detect magazine not separated during
unloading
Output magazine detect magazine not separated during
unloading
Loader’s platform is not empty
6
Unloader’s platform is not empty
6
Loader’s fork is not empty
6
Unloader’s fork is not empty
6
On loader’s platform, carrier is not placed properly.
6
On unloader’s platform, carrier is not placed properly.
6
On loader’s fork, carrier is not placed properly.
6
On unloader’s fork, carrier is not placed properly.
6
Benching operation in loading sequence fails
2
Safety module initialize failed
3
NSOL Rebond Before Skip Device Failed
8
Air pressure tolerance exceeded
5
Page - 297 - of 324
Jan 28, 2021 Rev 4.2
Kulicke & Soffa™
SECS/GEM Interface for K&S Ball Bonders
Bonder software version x-xx-x-473-series
ALID
(U2)
6708
6709
6710
6711
6712
6713
6714
6715
6716
6717
6718
6719
6720
6722
6723
6724
6725
6726
6727
6728
IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Alarms
ALTX
ALCD
Description
EH_OUTPUT_KIC
K_HOME_NOT_FO
UND
EH_OUTPUT_KIC
K_NOT_OUT_OF_
HOME
EH_LEFT_CLAW_
HOME_NOT_FOU
ND
EH_LEFT_CLAW_
NOT_OUT_OF_HO
ME
EH_RIGHT_CLAW
_HOME_NOT_FOU
ND
EH_RIGHT_CLAW
_NOT_OUT_OF_H
OME
EH_INPUT_KICK_
HOME_NOT_FOU
ND
EH_INPUT_KICK_
NOT_OUT_OF_HO
ME
EH_BK_CLAMP_H
OME_NOT_FOUN
D
EH_DOUBLE_LF_
DETECTED
EH_INPUT_LF_JA
M
EH_MH_MAG_NO
T_ON_INDEXER
EH_MH_MAG_NO
T_ON_INDEXER_
O
EH_MH_MAG_WR
ONG_ORIENTATI
ON
EH_MH_MAG_WR
ONG_ORIENTATI
ON_O
EH_MH_MAGAZIN
E_DROPPED
EH_MH_MAGAZIN
E_DROPPED_O
PDT-EFOTHRESHOLDFAULT
EH_PART_REJEC
TED_BY_HOST
EH_PART_BLOCK
ED_BY_HOST
6
Output kicker home not found
6
Output kicker not out of home
6
Left claw home not found
6
Left claw not out of home
6
Right claw home not found
6
Right claw not out of home
6
Input kicker home not found
6
Input kicker not out of home
6
Clamp home not found
6
Double LF detected
6
Input LF jammed
6
Input mag not on indexer
6
Output mag not on indexer
6
Input mag wrong oritentation
6
Output mag wrong orientation
6
Input mag dropped
6
Output mag dropped
6
EFO Limit Exceeded Fault
3
Host reject next part
3
Blocked for next part
Page - 298 - of 324
Jan 28, 2021 Rev 4.2
Kulicke & Soffa™
SECS/GEM Interface for K&S Ball Bonders
Bonder software version x-xx-x-473-series
ALID
(U2)
6729
6730
6731
6732
6733
6735
6736
6737
6738
6739
6740
6741
6742
6743
6744
6745
6746
6747
6748
6749
6750
IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Alarms
ALTX
ALCD
Description
EH_PART_WARNI
NG_BY_HOST
EH_PART_MAP_D
LOAD_TIMEOUT
EH_PART_MAP_D
LOAD_FAIL
PART_PROCESS_
RSLT_REJECTED
_BY_HOST
PART_PROCESS_
RSLT_VALIDATIO
N_TIMEOUT
EH_WALL_SENSO
R_CHECK_FAIL_D
URING_EJECT_LF
INPUT_CONVEYO
R_COMM_ERROR
OUTPUT_CONVEY
OR_COMM_ERRO
R
INPUT_CONVEYO
R_COMM_TIMEOU
T
OUTPUT_CONVEY
OR_COMM_TIME
OUT
INPUT_CONVEYO
R_ERROR
OUTPUT_CONVEY
OR_ERROR
INPUT_CONVEYO
R_WAIT_UPSTRE
AM_TIMEOUT
OUTPUT_CONVEY
OR_WAIT_DOWN
STREAM_TIMEOU
T
CONVEYOR_SAFE
TY_COVER_OPEN
PREHEAT_NOT_U
P
PREHEAT_NOT_D
OWN
INPUT_CONVEYO
R_NOT_READY
OUTPUT_CONVEY
OR_NOT_READY
INPUT_CONVEYO
R_COMM_TIMEOU
T_2
OUTPUT_CONVEY
OR_COMM_TIME
OUT_2
3
Warning for next part
3
partReceive timeout
3
partReceive fail
3
Host reject processed part
3
partProcessed timeout
2
ALID for the event error: output wall sensor checks failed during
ejecting L/F
6
Input conveyor communication error
6
Output conveyor communication error
6
Input conveyor communication timeout
6
Output conveyor communication timeout
6
Input conveyor error
6
Output conveyor error
6
Input conveyor waits for upstream timeout
6
Output conveyor waits for downstream timeout
6
Conveyor safety cover open
6
Preheat blade does not move up
6
Preheat blade does not move down
6
Input conveyor is reset and not ready to run
6
Output conveyor is reset and not ready to run
6
Input conveyor communication timeout (incoming command)
6
Output conveyor communication timeout (incoming command)
Page - 299 - of 324
Jan 28, 2021 Rev 4.2
Kulicke & Soffa™
SECS/GEM Interface for K&S Ball Bonders
Bonder software version x-xx-x-473-series
ALID
(U2)
6751
6752
6753
6754
6755
6756
6757
6758
6759
6760
6761
6762
6763
6764
6765
6766
6767
6768
6769
6770
6771
6772
6773
IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Alarms
ALTX
ALCD
Description
EH_NSOP_SKIP_D
EV_BY_BOND_NE
XT_WIRE_FAILED
EXT_2D_BCR_RE
AD_FAIL
REMOTE_PARMS
_UPLOAD_FAIL
REMOTE_PARMS
_DOWNLOAD_FAI
L
OUT_SLOT_LF_D
ETECTED
OMH_LF_RETAIN
ER_NOT_IN_POS
PDT_PULLTST_O
UT_OF_LIMIT
OUT_SLOT_LF_D
ETECTED_2
EH_BOFF_POS_IN
VALID
EH_MAG_SERVIC
E_POSI_NEED_RE
TURN
RPM_HEALTH_WA
RNING
RPM_NO_COMMS
RPM_SUBSYSTE
M_HEALTH_WAR
NING
RPM_ANALYTICS_
FAULT
EH_Z_LINK_WAR
M_UP_ABORT
BH_CI_COLL_PRE
_CONDITION_ERR
INPUT_LF_PICKU
P_HOME_NOT_FO
UND
INPUT_LF_PUSHE
R_HOME_NOT_FO
UND
OUTPUT_LF_GRIP
PER_HOME_NOT_
FOUND
INPUT_MH_EMPT
Y_FORK
INPUT_LF_PICKU
P_DETECT_FAIL
INPUT_LF_DROP_
ACTION_FAIL
INPUT_LF_STAND
BY_ACTION_FAIL
3
NSOP Skip Device by Bond Next Wire Failed
5
External 2D BCR read fail
6
Remote parameter upload failure
6
Remote parameter download failure
5
Out slot LF detected
5
OMH LF retainer not in position
2
ALID for the event error: Pull Test Out of Limit Error
5
Out slot LF detected for lot separation case
7
Bond Off Position Invalid
6
Find event EH_MAG_SERVICE_POSI_NEED_RETURN
6
RPM system unresponsive
6
6
Unable to communicate with RPM system
RPM subsystem unresponsive
6
RPM Analytics sytem error
6
ALID for the event error: Z-link warm up sequence is aborted
6
Bondhead clamp insert collision pre-condition check fails
6
VLF fork type input pickup home sensor not found
6
VLF fork type input pusher home sensor not found
6
VLF fork type output gripper home sensor not found
6
VLF fork type on-loader has no fork
6
VLF fork type input pickup fail to get lead frame
6
VLF fork type input pickup fail to drop lead frame on track
6
VLF fork type input pickup fail to go to standby position
Page - 300 - of 324
Jan 28, 2021 Rev 4.2
Kulicke & Soffa™
SECS/GEM Interface for K&S Ball Bonders
Bonder software version x-xx-x-473-series
ALID
(U2)
6774
6775
6776
6777
6778
6779
6780
6781
6782
6783
6784
6785
6787
6788
6789
6790
6791
6792
6793
6794
6795
IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Alarms
ALTX
ALCD
Description
INPUT_LF_PUSH_
ACTION_FAIL
OUTPUT_MH_EM
PTY_FORK
OUTPUT_LF_GRIP
_ACTION_FAIL
CI_SAFE_POS_SN
S_DETECT
ACC_ALIGNMENT
_ERROR
ACC_ROBOT_ERR
OR
RPM_DATAVIZ_FA
ULT
EH_PP_AUTO_CO
NV_FAIL
PREHEAT_VAC_N
OT_ON
PREHEAT_VAC_N
OT_OFF
EH_IDLE_PROMP
T_EJECT_LF_TIM
EOUT
EH_CD_SKIP_PR
OC_LIMIT_EXCEE
DED
INPUT_SMEMA_S
TART_TRANSFER
_TIMEOUT
INPUT_SMEMA_E
ND_TRANSFER_TI
MEOUT
INPUT_SMEMA_IN
VALID_ACK_SIG_
STATE
WIRE-INSP-WIRESTOP-ERR
6
VLF fork type input pusher fail to push lead frame in
6
VLF fork type off-loader has no fork
6
VLF fork type output gripper action fail
6
Clamp Insert Safe Position sensor is detected
6
Fail to find ACC alignment eyepoint
6
Auto cap changer reports error during cap change process
6
RPM DATAVIZ FAULT
6
5
ALID for the event error: process program auto conversion is
failed.
Preheat vacuum not on
5
Preheat vacuum not off
6
for EH EH_IDLE_PROMPT_EJECT_LF_TIMEOUT (Idle Mode
ECO Prompt To Eject Leadframes time out)
3
CD skipped processing - exceed limit
7
Input smema start transfer timeout error
7
Input smema end transfer timeout error
8
Input smema invalid acknowledgement signal state error
2
Alarm ID for EH #2560
Out of tolerance detected during Wire Inspection by wire.
WIRE-INSP-UNITSTOP-ERR
WIRE-INSPEXCEED-WARNLIMIT
WIRE-INSPREALIGNFAILURE
EH_Z_LINK_WAR
M_UP_COMPLETE
D
WIRE-INSP-IDNOT-TAUGHT
2
2
Out of tolerance detected during Wire Inspection by wire.
Alarm ID for EH #2561,
Out of tolerance detected during Wire Inspection by unit.
Alarm ID for EH #2562,
Exceed warn limit during Wire Inspection.
2
Alarm ID for EH #2563
Wire Inspection align failure.
6
Z-link warm up completion
2
Alarm ID for WIRE_INSP_ID_NOT_TAUGHT
Wire Inspection ID not taught
Page - 301 - of 324
Jan 28, 2021 Rev 4.2
Kulicke & Soffa™
SECS/GEM Interface for K&S Ball Bonders
Bonder software version x-xx-x-473-series
ALID
(U2)
6799
6800
6801
6802
6803
6804
6805
6806
6807
6808
6809
6810
6811
6812
6813
6814
6816
6817
IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Alarms
ALTX
ALCD
Description
EH_AUTO_LHM_L 6
OOP_HEIGHT_INV
ALID
EH_FILE_RENAME 7
_ERROR
MH_BLOCKED_BY
_INDEXER_ASSE
5
MBLY
INDEXER_ASSEM 7
BLY_INVALID_PO
S
EH_AUTO_BOND_ 6
FAB_FAIL
OUTLIER_WARNI
3
NG
EH_AUTO_BOND_ 6
SAMPLE_FAIL
AUTO_FORCE_VE 4
RIFICATION_FAIL
ED
PULLTST3
ENDING-FORCEREACHED
MH_FORK_ZAXIS_ 5
UPPER_SENSOR_
ON
MH_FORK_ZAXIS_ 5
UPPER_SENSOR_
ON_O
FORK_ZAXIS_SEE 5
K_TIMEOUT
FORK_ZAXIS_SEE 5
K_TIMEOUT_O
MH_FORK_ZAXIS_ 5
HOME_SENSOR_
ON
MH_FORK_ZAXIS_ 5
HOME_SENSOR_
ON_O
EH_EXT_SIG_MO
7
NIT_WARNING
MH_CMP_HSS_C
2
HK_ERR
MHS_X_SENSOR_ 3
BLOCKED
Auto loop height measurement too low or missing
Failed to rename file
Input mag handler blocked by indexer assembly error
Indexer assembly invalid position error
ALID for the event error: Auto Bond FAB is failed.
A signal value exceeded the warning limits
ALID for the event error: auto bond sample is failed.
Auto Bond Force Verification Failed
Pulltst ending force reached
CIS Loader fork z axis upper sensor is ON
CIS Unloader fork Z axis upper sensor is ON
CIS Loader fork Z axis seek sensor time out
CIS Unloader fork Z axis seek sensor time out
CIS Loader fork z axis home sensor is ON
CIS Unloader fork Z axis home sensor is ON
External signal monitor warning
Clamp home sensor check error
ALID for the event error: MHS detected X sensor blocked
Figure 61 – K&S Model Power Series Automatic Ball Bonder and K&S Model Gen-S Automatic Ball Bonder
Shared Alarms
6.6
K&S Model Power Series Automatic Ball Bonder and K&S Model Gen-S Automatic
Ball Bonder Shared Data Values
The Data Values (DVVALs) and associated Data Value IDs (DVIDs) shared by K&S Model Power Series Automatic
Ball Bonder and K&S Model Gen-S Automatic Ball Bonder are described in this section.
Page - 302 - of 324
Jan 28, 2021 Rev 4.2
Kulicke & Soffa™
SECS/GEM Interface for K&S Ball Bonders
Bonder software version x-xx-x-473-series
DVID
(U2)
10000
IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Data Values
Name
Type
Description
DVVAL_LimitVariab
le
DVVAL_TransitionT
ype
U2[1]
10002
DVVAL_EventLimit
B[1]
10003
DVVAL_ChangedE
C
DVVAL_Assist_ALI
D
DVVAL_Assist_Rea
son
DVVAL_Assist_Tex
t
DVVAL_Assist_Tim
e
Temperature_Auto_
Tune
DVVAL_LATEST_A
LID
DVVAL_LATEST_A
LTX
DVVAL_SINGLE_I
NTERACTIVER_T
M_ID
DVVAL_SINGLE_I
NTERACTIVER_S
ELECT_NAME
DVVAL_SUBSTRA
TE_MAP_DATA
U2[1]
10001
10004
10005
10006
10007
10008
10009
10010
10011
10012
10013
U2[1]
Used with the Limits Monitoring capability, contains the SVID
for the status variable whose value changed monitoring zones.
Used with the Limits Monitoring capability, defines the direction
of the zone transition which has occurred.
0 = Transition from lower to upper zone.
1 = Transition from upper to lower zone.
Used with the Limits Monitoring capability, contains the
LIMITID of the limit reached or crossed by LimitVariable. Since
multiple zone transitions for a variable may occur
simultaneously, EventLimit has been defined to allow for a list
of LIMITIDs.
Contains the ECID of the equipment constant whose value has
been changed by the operator.
Assist Alarm ID
U1[1]
Assist reason
A[N]
Assist text
U4[1]
Assist time
U1[1]
Temperature Auto Tune
U2[1]
Latest ALID
A[N]
Latest ALTX
A[N]
DVVAL SINGLE INTERACTIVER TM ID
A[N]
DVVAL SINGLE INTERACTIVER SELECT NAME
A[N]
DVVAL SUBSTRATE MAP DATA
B[1]
Figure 62 – K&S Model Power Series Automatic Ball Bonder and K&S Model Gen-S Automatic Ball Bonder
Shared Data Values
Page - 303 - of 324
Jan 28, 2021 Rev 4.2
Kulicke & Soffa™
SECS/GEM Interface for K&S Ball Bonders
Bonder software version x-xx-x-473-series
6.7
K&S Model Power Series Automatic Ball Bonder and K&S Model Gen-S Automatic
Ball Bonder GEM Compliance Statement
K&S Model Power Series Automatic Ball Bonder and
K&S Model Gen-S Automatic Ball Bonder GEM
COMPLIANCE STATEMENT
Fundamental GEM Requirements
Implemented
GEM Compliant
State Models
yes
no
Equipment Processing States
yes
no
Host-Initiated S1F13/F14 Scenario
yes
no
yes
Event Notification
yes
no
On-line Identification
yes
no
no
Error Messages
yes
no
Documentation
yes
no
Control (Operator-Initiated)
yes
no
Additional Capabilities
Implemented
GEM Compliant
Establish Communications
yes
no
yes
no
Dynamic Event Report Configuration
yes
no
yes
no
Variable Data Collection
yes
no
yes
no
Trace Data Collection
yes
no
yes
no
Status Data Collection
yes
no
yes
no
Alarm Management
yes
no
yes
no
Remote Control
yes
no
yes
no
Equipment Constants
yes
no
yes
no
Process Program Management
yes
no
yes
no
Material Movement
yes
no
yes
no
Equipment Terminal Services
yes
no
yes
no
Clock
yes
no
yes
no
Limits Monitoring
yes
no
yes
no
Spooling
yes
no
yes
no
Control (Host-Initiated)
yes
no
yes
no
Strip Mapping (Premium Option)
yes
no
yes
no
Figure 63 – K&S Model Power Series Automatic Ball Bonder and K&S Model Gen-S Automatic Ball Bonder
GEM Compliance Statement
7.
APPENDIX 3 - Summary of Software Changes
This section is a summary of the software changes applicable to SECS/GEM functionality.
Added remote command RCMD_DO_INDEX, RCMD_LF_IN_OUT, and RCMD_JOG_EJECT_MAG to Section
4.6.1
Updated remote commands ACCEPT_IN_MAG, ACCEPT_OUT_MAG, REJECT_IN_MAG, and
REJECT_OUT_MAG in the section 4.6.1.
Added 3319-3327, 3417-3418, 3621-3622, 3800-3830, and 4016-4029 to Section 6.2
Added 1098-1099, 1246, 1198-1199, 1239, 1403, 1508-1510, and 1603 to Section 6.3
Added 8050, 8335-8336, 8342-8343, 8402-8408, 8420, 8430-8431, 8440, 9012, 9492, 9502, 9512, 9760-9761,
10990-10991, 11090-11091, 11100-11101, 11110-11111, 11120-11121, 11130-11131, 11140-11141 and 1115011151 to Section 6.4
Added 6209-6215 to Section 6.5
Added S14F1 and S14F2 SECS-II message transaction.
Added strip map upload/download scenario, and HDL_BOND_POSITION in data set transfer scenario.
Added 3840 – 3844, 3850 – 3853 in Section 6.2
Removed 3822, 3823, 3024, 3025 in Section 6.2
Page - 304 - of 324
Jan 28, 2021 Rev 4.2
Kulicke & Soffa™
SECS/GEM Interface for K&S Ball Bonders
Bonder software version x-xx-x-473-series
Updated 3045, 3051, 3052, 3062, 3064, 3116, 3118, 3323, 3327 in Section 6.2
Added 1511-1514 in Section 6.3
Updated 1050, 1103, 1398, 1399, 1422 in Section 6.3
Removed 1004, 1603 in Section 6.3
Added 8450 – 8453, 8460, 8470 in Section 6.4
Updated 8130, 8200, 8201, 8202, 8322 – 8331, 8402 – 8405 in Section 6.4
Removed 8005, 8009, 8015 in Section 6.4
Added 6216 – 6218, 6200 in Section 6.5
Updated 6212 in Section 6.5
Added S10F1/F2 in Section 2.1
Added S14F1/F2 in Section 2.1
Added S10F1/F2 in Section 3.3
Updated MOVE_TO_IDLE in section 4.6
Added Strip Map download scenario in section 4.10
Removed Section 4.17
Updated SECS-II Message Detail for S1F14 in section 3.2.9
Added S14F1/F2 in Section 2.2
Added Remote Command: EXIT_HIT/PROCESS_START/RCMD_MAG_CONFIRM/RCMD_MAG_ID_SCAN_ACK/
RCMD_CLEAR_MAG_ASSIST/RCMD_EQP_STOP/RCMD_SUB_CONFIRM in Section 4.6.1
Added SVID 3119,3326,3361,3362,3363,3405,3406,3420,3421,3625,3823,3824,3825,3831,3854,3855,3856 in
section 6.2
Updated SVID 3403,3404 in section 6.2
Added ECID 1120,1121,1130,1192-1197,1247,1449,1450,1452-1458,1515-1604 in section 6.3
Updated ECID 1007,1070-1073,1115,1116,1198,1216,1219-1225,1427-1432,1445 in section 6.3
Added CEID 8025,8133-8135,8153,8154,8344-8347,8350,8360-8369,8432,8454,8461,8462,8471,8472,8480,910015081 in section 6.4
Added ALID 6196-6198,6219,6221-6680 in section 6.5
Added DVID 10009,10010 in section 6.6
Added Scenarios for Calibration Result Data in section 4.10
Added
CEID15160/15161/15180/15181/8902/8051/15170/15171/15190/15191/15200/15201/15210/15211/8136/8464 in
section 6.4
Added ALID6616/6618/6617/6619/6620/6621 in section 6.5
Added SVID3632/3633/3634/3635/3636/3637/4030/4031/3857/3364/3365/3366/3065/3066 in section 6.2
Added ECID1068/1563/1500 in section 6.3
Updated description for SV3512/CE8140 in section 6.2 and section 6.4
Updated explanation for BOND_PARM_LIMITS in section 4.18.1
Added SVID3829/ECID1125/1126/1127/1128/1129/1131/1132/CEID8115/8116/8117 for FEA3599
Added ALID6623/CEID15230/15231 for FEA3601
Added ALID6622/CEID15220/15221 for FEA3603
Added SVID3871/CEID8373 for FEA3605
Added SVID3067 for FEA3618
Added ECID1564 for KNScq36978
Rev 2.7 (bonder version 458)
Added CEID8390 for NFT1356
Added CEID15270/15271/ALID6627 for FEA3664
Added ECID1525 for FEA3666
Added ECID1575 for FEA3670
Added SVID 3650 for FEA3688
Added ECID 1140 for FEA3692
Rev 2.8 (bonder version 459)
Add ALID6628/CEID15280/15281 for FEA3703
Add ECID1576 for FEA3709
Add ALID6629/6630/CEID15290/15291/15300/15301 for FEA3715
Add CEID8118 for FEA3716
Page - 305 - of 324
Jan 28, 2021 Rev 4.2
Kulicke & Soffa™
SECS/GEM Interface for K&S Ball Bonders
Bonder software version x-xx-x-473-series
Rev 2.9 (bonder version 460)
Add CEID8338/CEID8339/CEID8340/CEID8341for NFT1374
Add CEID8348/CEID8349 for FEA3726
Add SVID3350/CEID8015 for FEA3737
Add CEID9870/CEID9871/CEID9880/CEID9881/CEID9890/CEID9891/CEID9900/CEID9901 for KNScq38374
Add ALID6087/ALID6088/ALID6089/ALID6090 for KNScq38374
Add ECID1150/ECID1151/ECID1152/ECID1153/ECID1154/ECID1155/ECID1156/ECID1157/ECID1158
/ECID1159 for FEA3775
Add SVID3638 for FEA3723
Add ECID1577/ECID1578 and CEID15340/CEID15341/CEID16210/CEID16211 and ALID6634 for FEA3721
Add CEID15310/CEID15311 and ALID6631 for FEA3774
Add ECID1580 and CEID8481/CEID8482/CEID8483/CEID8484/CEID8485/CEID8486/CEID8487/CEID8488
for FEA3736
Add CEID 15320/CEID15321/CEID15330/CEID15331/CEID8422 and ALID6632/ALID6633 for FEA3773
Rev 3.0 (bonder version 461)
Add ECID1579 for CEN1415
Add SVID3639 for CEN77
Add ECID1459 for CEN1423
Add SVID3068 for CEN1499
Add SVID3790/SVID3791 for CEN1753
Add ECID1581/ECID1582/ECID1583/ECID1584 for CEN1698
Add ECID1585 for CEN1996
Add SVID3874/SVID3875/SVID3876 and CEID8052/ECID8053 for FEA3741
Add ALID6635 and CEID15350/CEID15351 for KNScq38660
Add ALID6636/ALID6637/ALID6638 and CEID8155/CEID8156/CEID15360/CEID15361/CEID15370/CEID15371
/CEID15380/CEID15381/CEID15390/CEID15391 for CEN1991
Add Remote command MAG_EJECT_VERIFICATION for CEN1991
Add ALID6640 and CEID15400/CEID15401 for CEN1479
Add ECID1160/ECID1161 for CEN2421
Add ECID1586 for CEN2784
Rev3.1 (bonder version 462)
Add ECID1133/SVID3039/CEID8023 for CEN2663
Add CEID8119 for CEN2713
Add ALID6643/ALID6644/ALID6645 and CEID15430/CEID15431/CEID15440/CEID15441/CEID15450/CEID15451
for CEN94
Add ALID6642 and CEID8352/CEID15420/CEID15421 for CEN1959
Add ALID6648 and CEID15480/CEID15481 for CEN2499
Add ECID1587 and SVID3660/SVID3661 for CEN2754
Add ALID6650 and CEID8016/CEID15500/CEID15501 and ECID1141/ECID1142 for CEN3074
Add ALID6649 and CEID15490/CEID15491 for CEN3096
Add ALID6646/ALID6647 and CEID15460/CEID15461/CEID15470/CEID15471 for CEN3201
Add ECID1605 for CEN3243
Add ECID1588 for CEN4339
Add SVID3310 for KNScq39047
Add “DEFECT_ID_FILE” for 4.16 Data Set Transfer
Update Process Program grant status by add ACK 6 other error and ACK 7 No PFF file is installed
Update remote control command for 4.6
Rev3.2 (bonder version 463)
Add SVID3328 for CEN4261
Add ALID6651 and CEID15510/CEID15511 for CEN3338
Add ALID6652/ALID6653 and CEID15520/CEID15521/CEID15530/CEID15531 for CEN4170
Add ECID1589 for CEN4504
Add ECID1377/ECID1378/ECID1379/ECID1380 for CEN4546
Page - 306 - of 324
Jan 28, 2021 Rev 4.2
Kulicke & Soffa™
SECS/GEM Interface for K&S Ball Bonders
Bonder software version x-xx-x-473-series
Add ALID6654 and CEID15540/CEID15541 for CEN2465
Add SVID3206/SVID3207/SVID3208/SVID3209/SVID3210/SVID3211/SVID3212/SVID3213/SVID3214 and
CEID8203/CEID8204/CEID8205/CEID8206 for CEN4551
Add ALID6655 and CEID15550/CEID15551 for CEN4255
Add ECID1526 for CEN4627
Add ALID6656 and CEID15560/CEID15561 for BBBUG-530
Update RCMD table list in section 4.6
Update Data Set Upload/Download table list in section 4.18
Rev3.3 (bonder version 464)
Add CEID8142 and ECID1527 for BBBUG-1363
Add ALID6659 and CEID15590/CEID15591 for BBBUG-1628
Add ALID6609 and CEID15090/CEID15091 for BBBUG-1077
Add ECID1590/ECID1591 for CEN5162
Rev3.4 (bonder version 465)
Add ECID1708 and CEID8017/8018 for CEN5642
Add ALID6661 and CEID15610/15611 for CEN5420
Add ALID6660 and CEID15600/15601 for CEN5736
Add ALID6665 and CEID15650/15651 for CEN4956
Add ALID6662/6663/6664 and CEID15620/15621/15630/15631/15640/15641 for CEN5944
Add SVID3858 for BBBUG-1671
Rev3.5 (bonder version 466)
Add ECID1592/1593 for CEN6229
Add ALID6666/6667/6668/6669/6670/6671/6672/6673 and
CEID15660/15661/15670/15671/15680/15681/15690/15691/15700/15701/15710/15711/15720/15721/15730/15731
for CEN6253
Add SVID3859 for CEN6321
Add ALID6675 and CEID15750/15751 for CEN6368
Add ECID1069 for CEN6373
Add ECID1481/1482/1483/1484/1485/1486/1487/1488/1489/1490/1491/1492 and
SVID3476/3477/3478/3479/3480/3481/3482 for CEN6646
Add CEID8210 – 8254 and SVID3120 – 3176 and ECID1162/1163/1164/1165 for CEN6516
Rev3.6 (bonder version 467)
Update section1.1 Introduction to add SEMI support for E87/E40/E94
Add section4.11 Job Control to introduce new stream function
Add ALID6676 and CEID15760/15761 for CEN6592
Add ECID1170/1171/1172 for CEN6813
Add SVID 3641 for BBBUG-3516
Add SVID3021/3022 and CEID8064/8065 for BBBUG-3274
Add ALID6680/6681/6682 and CEID15800/15801/15810/15811/15820/15821 for CEN6949
Add CEID8255/8256/8257/8258/8259/8260/15780/15781/15790/15791 and ALID6678/6679
And ECID1135/1136/1137 and SVID3177/3178/3179/3180/3181/3182/3183 for CEN6705
Add ECID1612/1613/1614/1615/1616/1617/1618/1619/1620/1621/1622/1623 for CEN7225
Add ECID1594/1595/1596/1597 and SVID3070/3071/3072/3073 and CEID8473/15840/15841 and ALID6684 for
CEN6793
Add SVID3670/3671/3672/3673/3674/3675/3676/3677/3678/3679/3680 for CEN7372
Add CEID15830/15831 and ALID6683 for CEN6772
Add ECID1180/1181/1182 for CEN6827
Add ECID1528/1529 for CEN6785
Add CEID15860/15861 and ALID6686 for CEN6794
Add CEID15850/15851 and ALID6685 for BBBUG-5127
Add CEID15770/15771 and ALID6677 for CEN6498
Add CEID8354 for BBBUG-5197
Add ECID 1749/1750/1751/1752/1753/1754/1756/1757/1759/1760/1761/1762 and
Page - 307 - of 324
Jan 28, 2021 Rev 4.2
Kulicke & Soffa™
SECS/GEM Interface for K&S Ball Bonders
Bonder software version x-xx-x-473-series
SVID3329/3368/3369/3370/3371/3372/3373/3374/3375/3376/3377/3378/3379/3380/3381/3382/3383
And CEID8070/15870/15871/15880/15881/15890/15891/15900/15901/15910/15911/15920/15921/15930/15931
And ALID6687/6688/6689/6690/6691/6692/6693 for CEN6832
Add ECID1250 for BBBUG-5533
Add introduction about new SEMIE87/E40/E49 support in section 1.1
Add new section 4.11 Job Control to introduce new stream functions defined by E5/E87/E40/E94
Update remote control command table in section 4.6
Update data set upload/download table in section 4.19
Page - 308 - of 324
Jan 28, 2021 Rev 4.2
Kulicke & Soffa™
SECS/GEM Interface for K&S Ball Bonders
Bonder software version x-xx-x-473-series
Rev3.7 (bonder version 468)
Add ALID6694/6695 and CEID15940/15941/15950/15951 for CEN7877
Add ALID6726 and CEID16260/16261 for CEN8034
Add ALID6696/6697/6698/6699/6700/6701/6702/6703/6704 and
CEID15960/15961/15970/15971/15980/15981/15990/15991/16000/16001/16010/16011/16020/16021/16030/16031
/16040/16041 for CEN6830
Add ALID6706 and CEID16060/16061 for BBBUG-5915
Add remote command INSPECTION_CONFIRM for CEN6832
Add ECID1755/1758/1763/1764/1765/1770/1771 and
SVID3367/3384/3385/3386/3387/3388/3389/3390/3391/3392/3393/3394/3395/3396 and ALID6734 and
CEID16340/16341 and remote command INSPECTION_PARA_INFO_SEND for CEN7411
Add ALID6705 and CEID8160/8161/8162/8163/8164/8165/16050/16051 for CEN7539
Add SVID3330/3331 for CEN7951
Add ALID6708/6709/6710/6711/6712/6713/6714/6715/6716/6717/6718/6719/6720/6722/6723/6724/6725 and
CEID16080/16081/16090/16901/16100/16101/16110/16111/16120/16121/16130/16131/16140/16141/16150/16151
/16160/16161/16170/16171/16180/16181/16190/16191/16200/16201/16220/16221/16230/16231/16240/16241/162
50/16251 for CEN6892
Add ALID6707 and CEID16070/16071 for CEN7489
Add CEID8355 for CEN7827
Add CEID8080/8139 for CEN7541
Modify section 4.15 for AGV/OHT Auto Handling System Sequence support
Hide some unused ALID and update some name
Remove stream function for MMM only
Update RCMD table
Add Sample for S14F1/F2 in section 4.10
Remove section 10.5 Material Movement Management
Rev3.8 (bonder version 469)
Add ECID1329/1330/1331 for CEN8045
Add ALID6735 and CEID16350/16351 for CEN8069
Add ECID1138, SVID3190/3191 and CEID8267/8268 and RCMD RETRIEVE_CURRPP_LASTSAVED_TS for
CEN7831
Add ALID6745/6746 and CEID16450/16451/16460/16461 for CEN8142
Add ECID1173/1174 and CEID8067 for CEN8189
Add SVID3070/3071 for CEN6793
Add ALID6351 and CEID12510/12511 for CEN8333
Add ECID8066 for CEN7052
Add ALID6736/6737/6738/6739/6740/6741/6742/6743/6744/6747/6748/6749/6750 and
CEID8054/16360/16361/16370/16371/16380/16381/16390/16391/16400/16401/16410/16411/16420/16421/
16430/16431/16440/16441/16470/16471/16480/16481/16490/16491/16500/16501 for CEN8014
Add ALID6752 and CEID16520/16521 for CEN8187
Delete CEID11140/11141/ALID6114 and rename CEID12130/12131/ALID6313 for BBBUG6819
Add ALID6751 and CEID16510/16511 for CEN8194
Add ECID1145/1146/1147/1148 and
SVID3220/3221/3222/3223/3224/3225/3226/3227/3228/3229/3230/3231/3232/3233/3234/3235/3236/3237/3239
And
CEID8375/8376/8377/8378/8379/8380/8381/8382/8383/8384/8385/8386/8387/8388/16270/16271/16280/16281/
16290/16291/16300/16301/16310/16311/16320/16321/16330/16331 and
ALID6727/6728/6729/6730/6731/6732/6733 and RCMD PART_PROCESSED_RSLT_CONFIRM/
CHANGE_OVER_REQUEST/ TOOL_CHANGE_CONFIRM/ WIRE_CHANGE_CONFIRM for CEN8071
Add section 10.5 appendix for Data Set Transfer
Page - 309 - of 324
Jan 28, 2021 Rev 4.2
Kulicke & Soffa™
SECS/GEM Interface for K&S Ball Bonders
Bonder software version x-xx-x-473-series
Rev3.9 (bonder version 470)
Add ECID1606/1607 for CEN8500
Add ECID1460/1461/1462 for CEN8665
Add ECID1149 and SVID3240/3241/3242/3243/3244/3245/3246 and
CEID8489/8490/8491/8492/8493/8494/8495/8496/8497/8498/8490/8500/8501/8502 for CEN8701
Add ALID6753/6754 and CEID16530/16531/16540/16541 for CEN8682
Add ECID1470/1471 for CEN8748
Add SVID3247 and CEID8503 for BBBUG7178
Add SVID3700/3701/3702/3703/3704/3705/3706/3707/3708/3709/3710/3711/3712/3713/3714/3715 for CEN8777
Add ALID6757 and CEID16570/16571 for CEN7707
Add ECID1537/1538 and ALID6755/6756/6758 and CEID16550/16551/16560/16561/16580/16581 for CEN8778
Add ALID6759 and CEID16590/16591 for CEN8832
Add ECID1134 for BBBUG7276
Add ALID6760 and CEID16600/16601 for CEN8499
Add CEID8504/8505/8506/8507 for BBBUG7307
Rename ALID6706 and CEID16060/16061 for BBBUG7235
Update SVID3872/3873 to U4 type
Add SVID3248/3249/3250 and CEID8497/8498 for BBBUG7746
Add CEID8508/8509 for BBBUG7747
Add ALID6765 and CEID16650/16651 for CEN9017/BBBUG7862
Add ALID6766 and CEID16660/16661 for BBBUG7532
Add ALID6761/6762/6763/6764 and CEID16610/16611/16620/16621/16630/16631/16640/16641 for BBBUG7689
Page - 310 - of 324
Jan 28, 2021 Rev 4.2
Kulicke & Soffa™
SECS/GEM Interface for K&S Ball Bonders
Bonder software version x-xx-x-473-series
Rev4.0 (bonder version 471)
Add ALID6767/6768/6769/6770/6771/6772/6773/6774/6775/6776 and
CEID16670/16671/16680/16681/16690/16691/16700/16701/16710/16711/16720/16721/16730/16731/16740/16741
/16750/16751/16760/16761 for CEN9325
Add ECID1175/1176 for CEN9349
Add SVID3332 and CEID8356 for CEN9326
Add ECID1186/1187/1188/1189/1190/1191 for CEN9385
Add ECID1177 and SVID3662/3663 for CEN9428
Add ALID6778/6779 and CEID16780/16781/16790/16791 for CEN9094
Add ALID6777 and CEID16770/16771 for CEN9150
Rev4.1 (bonder version 472)
Add ALID6781 and CEID16810/16811/8120 and ECID1178/1179 for CEN9409
Add ALID6782/6783 and CEID16820/16821/16830/16831 for CEN9484
Add ECID1117 and ALID6785 and CEID16850/16851 for CEN9568
Add ALID6780 and CEID16800/16801 for CEN9272/CEN9380
Add ALID6784 and CEID16840/16841 for CEN9762
Add SVID3651 and ALID6790/6791/6792/6793 and CEID16900/16901/16910/16911/16920/16921/16930/16931 for
CEN9636
Add ALID6787/6788/6789 and CEID16870/16871/16880/16881/16890/16891 for CEN9728
Add ALID6794 and CEID16940/16941 for BBBUG-8492
Add ECID1166/1167 for CEN9790
Add ECID1780/1781/1782/1783/1784/1785/1786/1787/1788/1789/1790/1791/1792/1793/1794/1795/1796/
1797/1798 and SVID3880/3881/3882/3883/3884/3885/3886/3887/3888/3889/3890/3891/3892/3893/3894/3895/
3896/3897/3898 and ALID6795 and CEID8510/8511/8512/16950/16951 and RCMD
“RESET_PBI_WIRE_INSP_STATS” for CEN9636 phase2
Add ALID6799 and CEID16990/16991 for BBBUG-6444
Add ECID1255 for CEN9895
Update description of SVID3542 – 3565 PBI last unit statistics
Rev4.2 (bonder version 473)
Add ECID1628 and CEID8085/8086 for BBBUG9472
Add ALID6817 and CEID17170/17171 for BBBUG9422
Add ALID6816 and CEID17160/17161 for BBUG9406
Add ALID6806/6807 and CEID17060/17061/17070/17071 for CEN10394
Add ALID6814 and CEID17140/17141 for CEN10304
Add ALID6808/6809/6810/6811/6812/6813 and CEID17080/17081/17090/17091/17100/17101/17110/17111/
17120/17121/17130/17131 for CEN10395
Add ALID6803/6805 and CEID17030/17031/17050/17051 for CEN10059
Add ALID6804 and CEID17040/17041 for CEN10283
Add ALID6801/6802 and CEID17010/17011/17020/17021 for BBBUG8601
Add ECID1626/1627 for CEN10112
Add ALID6800 and CEID17000/17001 for BBBUG8567
Add CEID8389/8391/8392/8393/8394/8395/16960/16961/16970/16971/16980/16981 for CEN9990
Please refer to respective bonder software version release notes for the complete list of software changes.
8.
APPENDIX 4 - Summary of Document Changes
None
Page - 311 - of 324
Jan 28, 2021 Rev 4.2
Kulicke & Soffa™
SECS/GEM Interface for K&S Ball Bonders
Bonder software version x-xx-x-473-series
9.
APPENDIX 5 – Known Issues
None
10.
APPENDIX 6 – Sample Transactions and Scenarios
10.1
Communications
Enable Communications
* Received S1F13
* From Session ID 0. Wait on. Sys bytes 0x38564ba3.
<L [2]
<A '8028'>
* MDLN
<A '223E11'>
* SOFTREV
>
.
* Sending S1F14
* From Session ID 0. Wait off. Sys bytes 0x38564ba3.
<L [2]
<B 00>
* COMMACK
<L [0]
>
>
.
Equipment Test for Host Online
Equipment sends S1F1 to host
* Received S1F1
* From Session ID 0. Wait on. Sys bytes 0x38564ba6.
* Sending S1F2
* From Session ID 0. Wait off. Sys bytes 0x38564ba6.
<L [0]
>
.
Equipment informs host of Control State Change to Online Remote
* Received S6F11
* From Session ID 0. Wait off. Sys bytes 0x38564ba7.
<L [3]
<U2 0>
<U2 8002>
* Control State Changed To Online Remote
<L [1]
<L [2]
<U2 1> * Linked Report ID
<L [2]
<A '1999121516085000'>
<B 05>
>
>
>
>
.
10.2
Alarms
Enable All Alarms
* Sending S5F3
Page - 312 - of 324
Jan 28, 2021 Rev 4.2
Kulicke & Soffa™
SECS/GEM Interface for K&S Ball Bonders
Bonder software version x-xx-x-473-series
* From Session ID 0. Wait on. Sys bytes 0x000001bb.
<L [2]
<B 80>
* ALED
<U2>
* ALID
>
.
* Received S5F4
* From Session ID 0. Wait off. Sys bytes 0x000001bb.
<B 00>
.
Equipment Generated Alarm
* Received S5F1
* From Session ID 0. Wait on. Sys bytes 0x38564bb2.
<L [3]
<B 85>
<U2 6197>>
* Output barcode read alarm
<A 'MHS_OUT_BCR_FAIL'
>
.
* Sending S5F2
* From Session ID 0. Wait off. Sys bytes 0x38564bb2.
<B 00>
.
10.3
Collection Events and Reports
Disable All Collection Events
* Sending S2F37
* From Session ID 0. Wait on. Sys bytes 0x000001bc.
<L [2]
<BOOL F>
<L [0]
>
>
.
* Received S2F38
* From Session ID 0. Wait off. Sys bytes 0x000001bc.
<B 00>
.
Delete All Reports
* Sending S2F33
* From Session ID 0. Wait on. Sys bytes 0x000001bd.
<L [2]
<U2 0>
<L [0]
>
>
.
* Received S2F34
* From Session ID 0. Wait off. Sys bytes 0x000001bd.
<B 00>
.
Delete Specific Reports
* Sending S2F33
* From Session ID 0. Wait on. Sys bytes 0x000001d4.
Page - 313 - of 324
Jan 28, 2021 Rev 4.2
Kulicke & Soffa™
SECS/GEM Interface for K&S Ball Bonders
Bonder software version x-xx-x-473-series
<L [2]
<U2 0>
<L [7]
<L [2]
<U2 1>
<L [0]
>
>
<L [2]
<U2 4>
<L [0]
>
>
<L [2]
<U2 5>
<L [0]
>
>
<L [2]
<U2 7>
<L [0]
>
>
<L [2]
<U2 8>
<L [0]
>
>
<L [2]
<U2 9>
<L [0]
>
>
<L [2]
<U2 10>
<L [0]
>
>
>
>
* Report ID
* Report ID
* Report ID
* Report ID
* Report ID
* Report ID
* Report ID
.
* Received S2F34
* From Session ID 0. Wait off. Sys bytes 0x000001d4.
<B 00>
.
Unlink All Reports Linked to Specific Collection Events
* Sending S2F35
* From Session ID 0. Wait on. Sys bytes 0x000001de.
<L [2]
<U2 0>
<L [15]
<L [2]
<U2 8003> * Control State Changed To Offline
<L [0]
>
>
Page - 314 - of 324
Jan 28, 2021 Rev 4.2
Kulicke & Soffa™
SECS/GEM Interface for K&S Ball Bonders
Bonder software version x-xx-x-473-series
<L [2]
<U2 8001>
<L [0]
>
>
<L [2]
<U2 8002>
<L [0]
>
>
<L [2]
<U2 8004>
<L [0]
>
>
<L [2]
<U2 8011>
<L [0]
>
>
<L [2]
<U2 8103>
<L [0]
>
>
<L [2]
<U2 8300>
<L [0]
>
>
<L [2]
<U2 8302>
<L [0]
>
>
<L [2]
<U2 8301>
<L [0]
>
>
<L [2]
<U2 8303>
<L [0]
>
>
<L [2]
<U2 8311>
<L [0]
>
>
<L [2]
<U2 8312>
<L [0]
>
>
<L [2]
<U2 8313>
* Control State Changed To Online-Local
* Control State Changed To Online-Remote
* Process State Change
* Operator EC Change
* PP Select OK
* MHS_MAG_IN_READY
* MHS_MAG_IN_UNLOAD
* MHS_MAG_OUT_ READY
* MHS_MAG_OUT_UNLOAD
* CE_IN_LOAD_PORT_STATE_CHG
* CE_IN_UNLOAD_PORT_STATE_CHG
* CE_OUT_LOAD_PORT_STATE_CHG
Page - 315 - of 324
Jan 28, 2021 Rev 4.2
Kulicke & Soffa™
SECS/GEM Interface for K&S Ball Bonders
Bonder software version x-xx-x-473-series
<L [0]
>
>
<L [2]
<U2 8314>
<L [0]
>
>
<L [2]
<U2 8010>
<L [0]
>
>
>
>
* CE_OUT_UNLOAD_PORT_STATE_CHG
* MHS_MAG_OUT_BCR_REJECT
.
* Received S2F36
* From Session ID 0. Wait off. Sys bytes 0x000001de.
<B 00>
.
Define Reports
* Sending S2F33
* From Session ID 0. Wait on. Sys bytes 0x000001e8.
<L [2]
<U2 0>
<L [7]
<L [2]
<U2 1> * Report ID
<L [2]
<U2 3011> * Clock
<U2 3002> * ControlState
>
>
<L [2]
<U2 4> * Report ID
<L [3]
<U2 3011> * Clock
<U2 3007> * ProcessState
<U2 3008> * PreviousProcessState
>
>
<L [2]
<U2 5> * Report ID
<L [1]
<U2 10003> * ChangedEC
>
>
<L [2]
<U2 7> * Report ID
<L [1]
<U2 3004> * PPExecName
>
>
<L [2]
<U2 8> * Report ID
Page - 316 - of 324
Jan 28, 2021 Rev 4.2
Kulicke & Soffa™
SECS/GEM Interface for K&S Ball Bonders
Bonder software version x-xx-x-473-series
<L [2]
<U2
<U2
>
>
<L [2]
<U2
<L [4]
<U2
<U2
<U2
<U2
>
>
<L [2]
<U2
<L [1]
<U2
>
>
>
>
3304> * InputBarCode
3305>
9>
* Report ID
3035>
3036>
3037>
3038>
10>
* InLoadPortState
* InUnloadPortState
* OutLoadPortState
* OutUnloadPortState
* Report ID
3011> * Clock
.
* Received S2F34
* From Session ID 0. Wait off. Sys bytes 0x000001e8.
<B 00>
.
Link Reports to Collection Events
* Sending S2F35
* From Session ID 0. Wait on. Sys bytes 0x000001f2.
<L [2]
<U2 0>
<L [15]
<L [2]
<U2 8003> * Control State changed To Offline
<L [1]
<U2 1> * Report ID
>
>
<L [2]
<U2 8001> * Control State changed To Online-Local
<L [1]
<U2 1> * Report ID
>
>
<L [2]
<U2 8002> * Control State changed To Online-Remote
<L [1]
<U2 1> * Report ID
>
>
<L [2]
<U2 8004> * Process State Change
<L [1]
<U2 4> * Report ID
>
Page - 317 - of 324
Jan 28, 2021 Rev 4.2
Kulicke & Soffa™
SECS/GEM Interface for K&S Ball Bonders
Bonder software version x-xx-x-473-series
>
<L [2]
<U2 8011> * Operator EC Change
<L [1]
<U2 5> * Report ID
>
>
<L [2]
<U2 8103> * PP Select OK
<L [1]
<U2 7> * Report ID
>
>
<L [2]
<U2 8300> * MHS_MAG_IN_READY
<L [1]
<U2 8> * Report ID
>
>
<L [2]
<U2 8302> * MHS_MAG_INB_UNLOAD
<L [1]
<U2 8> * Report ID
>
>
<L [2]
<U2 8301> * MHS_MAG_OUT_READY
<L [1]
<U2 8> * Report ID
>
>
<L [2]
<U2 8303> * MHS_MAG_OUT_UNLOAD
<L [1]
<U2 8> * Report ID
>
>
<L [2]
<U2 8311> * CE_IN_LOAD_PORT_STATE_CHG
<L [1]
<U2 9> * Report ID
>
>
<L [2]
<U2 8312> * CE_IN_UNLOAD_PORT_STATE_CHG
<L [1]
<U2 9> * Report ID
>
>
<L [2]
<U2 8313> * CE_OUT_LOAD_PORT_STATE_CHG
<L [1]
<U2 9> * Report ID
>
>
<L [2]
<U2 8314> * CE_OUT_UNLOAD_PORT_STATE_CHG
Page - 318 - of 324
Jan 28, 2021 Rev 4.2
Kulicke & Soffa™
SECS/GEM Interface for K&S Ball Bonders
Bonder software version x-xx-x-473-series
<L [1]
<U2 9> * Report ID
>
>
<L [2]
<U2 8010> * TerminalMsgAck
<L [1]
<U2 10> * Report ID
>
>
>
>
.
* Received S2F36
* From Session ID 0. Wait off. Sys bytes 0x000001f2.
<B 00>
.
Enable Specific Collection Events
* Sending S2F37
* From Session ID 0. Wait on. Sys bytes 0x000001f8.
<L [2]
<BOOL T>
<L [15]
<U2 8003>
* Control State changed to Offline
<U2 8001>
* Control State changed to Online-Local
<U2 8002>
* Control State changed to Online-Remote
<U2 8004>
* Process State Change
<U2 8011>
* Operator EC Change
<U2 8103>
* PP Select OK
<U2 8300>
* MHS_MAG_IN_READY
<U2 8302>
* MHS_MAG_IN_UNLOAD
<U2 8301>
* MHS_MAG_OUT_READY
<U2 8303>
* MHS_MAG_OUT_UNLOAD
<U2 8311>
* CE_IN_LOAD_PORT_STATE_CHG
<U2 8312>
* CE_IN_UNLOAD_PORT_STATE_CHG
<U2 8313>
* CE_OUT_LOAD_PORT_STATE_CHG
<U2 8314>
* CE_OUT_UNLOAD_PORT_STATE_CHG
<U2 8010>
* TerminalMsgAck
>
>
.
* Received S2F38
* From Session ID 0. Wait off. Sys bytes 0x000001f8.
<B 00>
.
10.4
Equipment Status
Host Request for Selected Status Variable Values
* Sending S1F3
* From Session ID 0. Wait on. Sys bytes 0x0000020c.
<L [10]
<U2 3011>
* Clock
<U2 3002>
* ControlState
<U2 3007>
* ProcessState
<U2 3035>
* InLoadPortState
<U2 3036>
* InUnloadPortState
Page - 319 - of 324
Jan 28, 2021 Rev 4.2
Kulicke & Soffa™
SECS/GEM Interface for K&S Ball Bonders
Bonder software version x-xx-x-473-series
<U2
<U2
<U2
<U2
<U2
>
3037>
3038>
3004>
3304>
3305>
* OutLoadPortState
* OutUnloadPortState
* PPExecName
* Input Bar Code
* Output Bar Code
.
* Received S1F4
* From Session ID 0. Wait off. Sys bytes 0x0000020c.
<L [10]
<A '1999121516135600'>
<B 05>
<U1 1>
<U2 0>
<U2 0>
<U2 1>
<U2 1>
<A 'GENERIC.BND'>
<A ''>
<A ''>
>
.
Event Report From Equipment
* Received S6F11
* From Session ID 0. Wait off. Sys bytes 0x38564bb3.
<L [3]
<U2 0>
<U2 8004>
* Process State Change
<L [1]
<L [2]
<U2 4> * Report ID
<L [3]
<A '1999121516170800'> * Clock
<U1 3>
* ProcessState (Assist)
<U1 2>
* PreviousProcessState (Auto Run)
>
>
>
>
.
10.5
Data Set Transfer
Open Data Set To Upload File
Sample: upload error.log file to host
Page - 320 - of 324
Jan 28, 2021 Rev 4.2
Kulicke & Soffa™
SECS/GEM Interface for K&S Ball Bonders
Bonder software version x-xx-x-473-series
Host
<ECID - SET the filename>
S2F15 (Host)(29 bytes) -- Header: ( 00 00 82 0F 00 00 00 00 00 0F )
---<L [1]
------<L [2]
---------<U2[1]
1563>
---------<A [9]
error.log>
------>
--->
Equipment
<Acknowledge>
S2F16 (WB)(13 bytes) -- Header: ( 00 00 02 10 00 00 00 00 00 0F )
---<B [1]
0>
<Open Data Set Request>
S13F3 (Host)(43 bytes) -- Header: ( 00 00 8D 03 00 00 00 00 00 11 )
---<L [3]
------<U2[1]
24201>
------<A [19]
INDIVIDUAL_LOG_FILE>
------<U4[1]
<Open Data Set Data>
S13F4 (WB)(50 bytes) -- Header: ( 00 00 0D 04 00 00 00 00 00 11 )
---<L [5]
------<U2[1]
24201>
------<A [19]
INDIVIDUAL_LOG_FILE>
------<B [1]
0>
------<U2[1]
0>
------<U4[1]
0>
--->
<Read Data Set Request>
S13F5 (Host)(22 bytes) -- Header: ( 00 00 8D 05 00 00 00 00 00 12 )
---<L [2]
------<U2[1]
24201>
------<U4[1]
0>
--->
<Read Data set Data – error.log >
S13F6 (WB)(16621 bytes) -- Header: ( 00 00 0D 06 00 00 00 00 00 12 )
---<L [4]
------<U2[1]
24201>
------<B [1]
0>
------<U4[1]
0>
------<L [1]
---------<B [16591] 23 23 0A 42 4F 4E 44 45 52 20 52 45 42 4F 4F 54
45 44 0A 4C 4F 47 20 43 52 45 41 54 45 44 3A 20
4D 4F 4E 20 41 55 47 20 30 35 20 31 37 3A 33 33
3A 33 33 20 32 30 31 39 20 33 34 39 0A 23 23 0A
3C 35 30 3E 20 4F 50 5F 41 53 53 49 53 54 5F 43
4F 4D 50 4C 45 54 45 0A 4D 4F 4E 20 41 55 47 20
30 35 20 31 37 3A 33 34 3A 34 30 20 32 30 31 39
20 36 36 20 20 20 3C 78 31 37 63 33 66 3E 0A 5B
31 31 33 30 5D 0A 23 23 0A 42 4F 4E 44 45 52 20
52 45 42 4F 4F 54 45 44 0A 4C 4F 47 20 41 50 50 >
Remainder of file truncated
------>
Page - 321 - of 324
Jan 28, 2021 Rev 4.2
Kulicke & Soffa™
SECS/GEM Interface for K&S Ball Bonders
Bonder software version x-xx-x-473-series
<Read Data Set Request>
S13F5 (PC)(22 bytes) -- Header: ( 00 00 8D 05 00 00 00 00 00 13 )
---<L [2]
------<U2[1]
24201>
------<U4[1]
0>
--->
<Read Data Set Data>
S13F6 (WB)(27 bytes) -- Header: ( 00 00 0D 06 00 00 00 00 00 13 )
---<L [4]
------<U2[1]
24201>
------<B [1]
8>
------<U4[1]
-1>
------<L [0]>
--->
<Close Data Set Send>
S13F7 (PC)(16 bytes) -- Header: ( 00 00 8D 07 00 00 00 00 00 14 )
---<L [1]
------<U2[1]
24201>
--->
<Close Data Set ACK>
S13F8 (WB)(19 bytes) -- Header: ( 00 00 0D 08 00 00 00 00 00 14 )
---<L [2]
------<U2[1]
24201>
------<B [1]
0>
--->
Open Data Set to Download File
Sample: Download DEFECTID.txt file to bonder
Host
Equipment
< Send Data Set>
S13F1 (Host) (28 bytes) -- Header: ( 00 00 8D 01 00 00 00 00 00 05 )
---<L [1]
------<A [14]
DEFECT_ID_FILE>
--->
< Send Data Set ACK>
S13F2 (WB)(29 bytes) -- Header: ( 00 00 0D 02 00 00 00 00
00 05 )
---<A [14]
DEFECT_ID_FILE>
---<B [1]
0>
<Open Data Set>
S13F3 (WB)(38 bytes) -- Header: ( 00 00 0D 03 00 00 83
FD 63 5D )
---<L [3]
------<U2[1]
12>
------<A [14]
DEFECT_ID_FILE>
------<U4[1]
0>
--->
<Open Data Set ACK>
S13F4 (Host)(45 bytes) -- Header: ( 00 00 0D 04 00 00 83 FD 63 5D )
---<L [5]
------<U2[1]
12>
------<A [14]
DEFECT_ID_FILE>
Page - 322 - of 324
Jan 28, 2021 Rev 4.2
Kulicke & Soffa™
SECS/GEM Interface for K&S Ball Bonders
Bonder software version x-xx-x-473-series
------<B [1]
0>
------<U2[1]
0>
------<U4[1]
0>
--->
<Read Data Set>
S13F5 (WB)(22 bytes) -- Header: ( 00 00 0D 05 00 00 84
FD 63 5D )
---<L [2]
------<U2[1]
12>
------<U4[1]
130102876>
--->
<Read Data Set ACK>
S13F6 (Host)(30 bytes) -- Header: ( 00 00 0D 06 00 00 84 FD 63 5D )
---<L [4]
------<U2[1]
12>
------<B [1]
0>
------<U4[1]
0>
------<L [1]
---------<B [282]
31 31 20 4B 4E 53 5F 4F 55 54 50 55 54 5F 47 4F
4F 44 0D 0A 32 32 20 4B 4E 53 5F 49 4E 50 55 54
5F 44 45 46 45 43 54 0D 0A 33 33 20 4B 4E 53 5F
52 45 4A 45 43 54 5F 44 46 4C 54 0D 0A 34 34 20
4B 4E 53 5F 4E 4F 54 5F 42 4F 4E 44 45 44 0D 0A
31 32 20 4C 4C 41 56 20 2D 20 4C 42 20 4F 4E 20
4C 45 41 44 20 41 54 20 56 45 52 54 49 43 41 4C
0D 0A 37 33 20 4C 4C 41 46 20 2D 20 4C 42 20 4F
4E 20 4C 45 41 44 20 41 54 20 46 45 4E 43 45 0D
0A 37 34 20 42 57 41 56 20 2D 20 42 4F 4E 44 45
Remainder of file truncated>
------>
--->
---- Sent bytes 1 to 282 of 282 bytes total
<Read Data Set>
S13F5 (WB)(22 bytes) -- Header: ( 00 00 0D 05 00 00 85
FD 63 5D )
---<L [2]
------<U2[1]
12>
------<U4[1]
130102876>
--->
<Read Data Set ACK>
S13F6 (Host)(27 bytes) -- Header: ( 00 00 0D 06 00 00 85 FD 63 5D )
---<L [4]
------<U2[1]
12>
------<B [1]
8>
------<U4[1]
0>
------<L [0]>
--->
---- Sent EOF
Page - 323 - of 324
Jan 28, 2021 Rev 4.2
Kulicke & Soffa™
SECS/GEM Interface for K&S Ball Bonders
Bonder software version x-xx-x-473-series
<Close Data Set>
S13F7 (WB)(16 bytes) -- Header: ( 00 00 0D 07 00 00 86
FD 63 5D )
---<L [1]
------<U2[1]
--->
<Close Data Set ACK>
S13F8 (Host)(19 bytes) -- Header: ( 00 00 0D 08 00 00 86 FD 63 5D )
---<L [2]
------<U2[1]
12>
------<B [1]
0>
--->
Page - 324 - of 324