Kulicke & Soffa SECS/GEM Interface for K&S Model Power Series Automatic Ball Bonder, K&S Model Gen-S Automatic Ball Bonder, Running 8-88-4-72 The information in this document is the property of Kulicke & Soffa. Any reproduction or distribution to a third party is strictly forbidden unless written permission is given by an authorized agent of Kulicke & Soffa. Kulicke & Soffa Pte Ltd 23A Serangoon North Ave 5 #01-01 K&S Corporate Headquarters Singapore 554369 Phone: +65-6880-9600 Fax: +65-6880-9580 Document Revision 4.1 Sep 18, 2020 SECS/GEM Interface for Ball Bonders Bonder software version x-xx-x-472-series Table of Contents 1. GENERAL INFORMATION .................................................................. - 10 1.1 1.2 1.3 INTRODUCTION ................................................................................................................................... - 10 MANUFACTURER AND PRODUCT MODEL ............................................................................................ - 10 GENERAL DESCRIPTION OF EQUIPMENT FUNCTION ............................................................................ - 10 Intended Function of Interface ................................................................................................ - 10 Software Version Number ....................................................................................................... - 10 - 2. SECS-II MESSAGE SUMMARY .......................................................... - 13 2.1 2.2 HOST-ORIGINATED T RANSACTIONS ................................................................................................... - 13 EQUIPMENT-ORIGINATED T RANSACTIONS .......................................................................................... - 15 - 3. SECS-II MESSAGE DETAIL ................................................................ - 16 3.1 3.2 DATA ITEMS ....................................................................................................................................... - 16 Data Dictionary........................................................................................................................ - 16 Status Variables ....................................................................................................................... - 25 Equipment Constants .............................................................................................................. - 25 Collection Events ..................................................................................................................... - 25 Alarms...................................................................................................................................... - 25 HOST-ORIGINATED T RANSACTIONS ................................................................................................... - 25 Sx,F0 Abort Transaction (SxF0).............................................................................................. - 25 S1,F1 Are You There Request (R) ........................................................................................... - 25 S1,F2 On Line Data (D) ........................................................................................................... - 25 S1,F3 Selected Equipment Status Request (SSR) .................................................................... - 25 S1,F4 Selected Equipment Status Data (SSD) ......................................................................... - 26 S1,F11 Status Variable Namelist Request (SVNR) ................................................................. - 26 S1,F12 Status Variable Namelist Reply (SVNRR) .................................................................. - 26 S1,F13 Establish Communications Request (CR) ................................................................... - 26 S1,F14 Establish Communications Request Acknowledge (CRA) .......................................... - 27 S1,F15 Request OFF-LINE (ROFL) ....................................................................................... - 27 S1,F16 OFF-LINE Acknowledge (OFLA) ............................................................................... - 27 S1,F17 Request ON-LINE (RONL) ......................................................................................... - 27 S1,F18 ON-LINE Acknowledge (ONLA) ................................................................................ - 27 S2,F13 Equipment Constant Request (ECR) .......................................................................... - 27 S2,F14 Equipment Constant Data (ECD)................................................................................ - 27 S2,F15 New Equipment Constant Send (ECS) ........................................................................ - 27 S2,F16 New Equipment Constant Acknowledge (ECA).......................................................... - 28 S2,F17 Date and Time Request (DTR) .................................................................................... - 28 S2,F18 Date and Time Data (DTD) ......................................................................................... - 28 S2,F23 Trace Initialize Send (TIS) .......................................................................................... - 28 S2,F24 Trace Initialize Acknowledge (TIA) ............................................................................ - 28 S2,F29 Equipment Constant Namelist (ECNR) ...................................................................... - 29 S2,F30 Equipment Constant Namelist (ECN) ......................................................................... - 29 S2,F31 Date and Time Set Request (DTS) ............................................................................... - 29 S2,F32 Date and Time Set Acknowledge (DTA) ..................................................................... - 29 S2,F33 Define Report (DR) ...................................................................................................... - 29 S2,F34 Define Report Acknowledge (DRA) ............................................................................ - 30 S2,F35 Link Event Report (LER) ............................................................................................ - 31 S2,F36 Link Event Report Acknowledge (LERA) .................................................................. - 31 S2,F37 Enable/Disable Event Report (EDER) ........................................................................ - 32 S2,F38 Enable/Disable Event Report Acknowledge (EERA) .................................................. - 32 S2,F39 Multi-Block Inquire (MBI) .......................................................................................... - 32 S2,F40 Multi-Block Grant (MBG)........................................................................................... - 32 Page ii of 321 Sep 18, 2020 Rev 4.1 Kulicke & Soffa™ SECS/GEM Interface for Ball Bonders Bonder software version x-xx-x-472-series Table of Contents 3.3 S2,F41 Host Command Send (HCS) ........................................................................................ - 32 S2,F42 Host Command Acknowledge (HCA) ......................................................................... - 33 S2,F43 Reset Spooling Streams and Functions (RSSF) ........................................................... - 33 S2,F44 Reset Spooling Acknowledge (RSA) ............................................................................ - 34 S2,F45 Define Variable Limit Attributes (DVLA) .................................................................. - 34 S2,F46 Variable Limit Attribute Acknowledge (VLAA)......................................................... - 35 S2,F47 Variable Limit Attribute Request (VLAR) ................................................................. - 36 S2,F48 Variable Limit Attributes Send (VLAS) ..................................................................... - 36 S5,F3 Enable/Disable Alarm Send (EAS) ................................................................................ - 37 S5,F4 Enable/Disable Alarm Acknowledge (EAA) ................................................................. - 37 S5,F5 List Alarms Request (LAR) ........................................................................................... - 37 S5,F6 List Alarms Data (LAD) ................................................................................................ - 38 S6,F15 Event Report Request (ERR) ...................................................................................... - 38 S6,F16 Event Report Data (ERD)............................................................................................ - 39 S6,F19 Individual Report Request (IRR) ................................................................................ - 39 S6,F20 Individual Report Data (IRD) ..................................................................................... - 39 S6,F23 Request Spooled Data (RSD) ....................................................................................... - 39 S6,F24 Request Spooled Data Acknowledgment Send (RSDAS) ............................................ - 39 S7,F1 Process Program Load Inquire (PPI) ............................................................................ - 40 S7,F2 Process Program Load Grant (PPG)............................................................................. - 40 S7,F3 Process Program Send (PPS) ......................................................................................... - 40 S7,F4 Process Program Acknowledge (PPA) .......................................................................... - 40 S7,F5 Process Program Request (PPR) ................................................................................... - 40 S7,F6 Process Program Data (PPD) ........................................................................................ - 40 S7,F17 Delete Process Program Send (DPS) ........................................................................... - 40 S7,F18 Delete Process Program Acknowledge (DPA) ............................................................. - 41 S7,F19 Current EPPD Request (RER) .................................................................................... - 41 S7,F20 Current EPPD Data (RED) ......................................................................................... - 41 S10,F3 Terminal Display, Single (VTN) .................................................................................. - 41 S10,F4 Terminal Display, Single Acknowledge (VTA) ........................................................... - 41 S10,F5 Terminal Display, Multi-Block(VTM) ........................................................................ - 41 S10,F6 Terminal Display, Multi-Block Acknowledge (VMA) ................................................. - 42 S13,F1 Send Data Set Send (DSSS) ......................................................................................... - 42 S13,F2 Send Data Set Acknowledge (DSSA) ........................................................................... - 42 EQUIPMENT-ORIGINATED T RANSACTIONS .......................................................................................... - 43 Sx,F0 Abort Transaction (SxF0).............................................................................................. - 43 S1,F1 Are You There Request (R) ........................................................................................... - 43 S1,F2 On Line Data (D) ........................................................................................................... - 43 S1,F13 Establish Communications Request (CR) ................................................................... - 43 S1,F14 Establish Communications Request Acknowledge (CRA) .......................................... - 43 S5,F1 Alarm Report Send (ARS)............................................................................................. - 43 S5,F2 Alarm Report Acknowledge (ARA) .............................................................................. - 43 S6,F1 Trace Data Send ............................................................................................................ - 44 S6,F2 Trace Data Acknowledge............................................................................................... - 44 S6,F5 Multi-block Data Send Inquire (MBI) .......................................................................... - 44 S6,F6 Multi-block Grant (MBG) ............................................................................................. - 44 S6,F11 Event Report Send (ERS) ............................................................................................ - 44 S6,F12 Event Report Acknowledge (ERA) .............................................................................. - 45 S7,F1 Process Program Load Inquire (PPI) ............................................................................ - 45 S7,F2 Process Program Load Grant (PPG)............................................................................. - 45 S7,F3 Process Program Send (PPS) ......................................................................................... - 45 Page iii of 321 Sep 18, 2020 Rev 4.1 Kulicke & Soffa™ SECS/GEM Interface for Ball Bonders Bonder software version x-xx-x-472-series Table of Contents S7,F4 Process Program Acknowledge (PPA) .......................................................................... - 45 S7,F5 Process Program Request (PPR) ................................................................................... - 46 S7,F6 Process Program Data (PPD) ........................................................................................ - 46 S9,F1 Unrecognized Device ID (UDN)..................................................................................... - 46 S9,F3 Unrecognized Stream Type (USN) ................................................................................ - 46 S9,F5 Unrecognized Function Type (UFN) ............................................................................. - 47 S9,F7 Illegal Data (IDN) .......................................................................................................... - 47 S9,F9 Transaction Timer Timeout (TTN) ............................................................................... - 47 S9,F11 Data Too Long (DLN) .................................................................................................. - 47 S10, F1 Terminal Request (TRN) ............................................................................................ - 47 S10, F2 Terminal Request Acknowledge (TRA) ..................................................................... - 47 S13,F3 Open Data Set Request (DSOR) .................................................................................. - 47 S13,F4 Open Data Set Data (DSOD) ....................................................................................... - 47 S13,F5 Read Data Set Request (DSRR) ................................................................................... - 48 S13,F6 Read Data Set Data (DSRD) ........................................................................................ - 48 S13,F7 Close Data Set Send (DSCS) ........................................................................................ - 48 S13,F8 Close Data Set Acknowledge (DSCA).......................................................................... - 48 S14,F1 GetAttr Request(GAR) ................................................................................................ - 48 S14,F2 GetAttr Data (GAD) .................................................................................................... - 49 - 4. STATE MODELS, CAPABILITIES, AND SCENARIOS ................... - 50 4.1 4.2 4.3 4.4 4.5 COMMUNICATIONS .............................................................................................................................. - 50 Communications State Model.................................................................................................. - 50 Communications State Transitions ......................................................................................... - 52 Host Attempts to Establish Communications.......................................................................... - 53 Host-Initiated Are You There ................................................................................................. - 53 Equipment-Initiated Are You There ....................................................................................... - 53 CONTROL ........................................................................................................................................... - 54 Control State Model................................................................................................................. - 54 Control State Transitions ........................................................................................................ - 55 Host Accepts ON-LINE ........................................................................................................... - 55 Host Denies ON-LINE ............................................................................................................. - 56 Operator Sets OFF-LINE ........................................................................................................ - 56 Operator Sets REMOTE ......................................................................................................... - 56 Operator Sets LOCAL............................................................................................................. - 56 Host Sets OFF-LINE ............................................................................................................... - 56 Host Sets ON-LINE ................................................................................................................. - 57 PROCESS ........................................................................................................................................... - 57 Process State Model ................................................................................................................. - 57 Process State Transitions ......................................................................................................... - 58 Process States........................................................................................................................... - 58 DATA COLLECTION ............................................................................................................................. - 59 Event Data Collection .............................................................................................................. - 59 Host Requests Collection Event Report .................................................................................. - 59 Collection Event Reporting Setup ........................................................................................... - 59 Host Requests Report .............................................................................................................. - 59 Equipment Status Report ........................................................................................................ - 60 Equipment Status Variable Namelist Report .......................................................................... - 60 ALARMS ............................................................................................................................................. - 60 Enable/Disable Alarms ............................................................................................................ - 60 Upload Alarm Information...................................................................................................... - 60 Page iv of 321 Sep 18, 2020 Rev 4.1 Kulicke & Soffa™ SECS/GEM Interface for Ball Bonders Bonder software version x-xx-x-472-series Table of Contents 4.6 4.7 4.8 4.9 4.10 4.11 4.12 4.13 4.14 4.15 4.16 Alarm Detected By Equipment................................................................................................ - 60 REMOTE CONTROL ............................................................................................................................. - 60 Host Sends Remote Command to Equipment ......................................................................... - 60 EQUIPMENT CONSTANTS .................................................................................................................... - 70 Host Sends Equipment Constants ........................................................................................... - 70 Host Equipment Constants Request ........................................................................................ - 70 Host Equipment Constants Namelist Request......................................................................... - 70 PROCESS PROGRAMS ........................................................................................................................ - 70 Process Program Deletion By Host.......................................................................................... - 70 Host-Initiated Process Program Upload (Unformatted) ......................................................... - 70 Equipment-Initiated Process Program Download (Unformatted) .......................................... - 72 Process Program Directory Request ....................................................................................... - 72 Host-Initiated Process Program Download (Unformatted) .................................................... - 72 Equipment-Initiated Process Program Upload (Unformatted) .............................................. - 73 T ERMINAL SERVICES .......................................................................................................................... - 73 Host Sends Information to Equipment’s Display Device ........................................................ - 73 Host Sends Multi-block Message to Equipment’s Display Device .......................................... - 74 Operator Sends Information to Host ....................................................................................... - 74 STRIP MAP ......................................................................................................................................... - 75 Get Strip Map Attribute Data ................................................................................................. - 75 S14,F1 Sample Message ........................................................................................................... - 75 S14,F2 Sample Message ........................................................................................................... - 80 Query Cell Status/Cell Grade Data ......................................................................................... - 82 JOB CONTROL .................................................................................................................................... - 83 S3F17/S3F18 Stream Function ................................................................................................ - 83 S14F9/S14F10 Stream Function .............................................................................................. - 84 S16F15/S16F16 Stream Function ............................................................................................ - 85 S16F21/S16F22 Stream Function ............................................................................................ - 87 S16F27/S16F28 Stream Function ............................................................................................ - 87 S16F5/S16F6 Stream Function ................................................................................................ - 87 CALIBRATION RESULT DATA .............................................................................................................. - 88 Get Calibration Data ............................................................................................................... - 88 Calibration Results Object Attribute Table ............................................................................ - 89 Calibration Name and OBJID Mapping ................................................................................. - 90 Content of Attribute “CalData” .............................................................................................. - 91 ERROR MESSAGES............................................................................................................................. - 92 Message Fault Due to Unrecognized Device ID ....................................................................... - 92 Message Fault Due to Unrecognized Stream Type .................................................................. - 92 Message Fault Due to Unrecognized Function Type ............................................................... - 92 Message Fault Due to Illegal Data Format .............................................................................. - 92 Message Fault Due to Transaction Timer Timeout................................................................. - 92 SPOOLING .......................................................................................................................................... - 93 Spooling State Model ............................................................................................................... - 93 Spooling State Transitions ....................................................................................................... - 93 Host Defines Set of Messages to be Spooled ............................................................................ - 94 Define Maximum Number of Messages to Send in Response to S6,F23 ................................. - 94 Request and Delete Spooled Data ............................................................................................ - 94 AUTOMATED MATERIAL MOVEMENT MANAGEMENT ........................................................................... - 95 AGV/OHT Auto Handling System Sequence (Premium Option) ........................................... - 95 KNS Bonder to Host Events And Applicable SVID ................................................................ - 98 ENHANCED OPERATOR DATA ENTRY ................................................................................................. - 98 Page v of 321 Sep 18, 2020 Rev 4.1 Kulicke & Soffa™ SECS/GEM Interface for Ball Bonders Bonder software version x-xx-x-472-series Table of Contents Overview .................................................................................................................................. - 98 Operator Data Entry #1 Dialog - Host Definable Items .......................................................... - 98 Operator Data Entry #2 Dialog - Host Definable Items .......................................................... - 98 4.17 OS FILE DOWNLOAD SCENARIO FOR REMOTE INSTALLATION.......................................................... - 100 4.18 TRACE: EXAMPLE OS_FILE_DWNLD SCENARIO ......................................................................... - 101 4.19 DATA SET T RANSFERS ..................................................................................................................... - 102 Data Set Upload ..................................................................................................................... - 102 Data Set Download ................................................................................................................ - 102 - 5. MESSAGE TRANSFER PROTOCOLS ............................................ - 103 5.1 5.2 HIGH-SPEED SECS MESSAGE SERVICES (HSMS) .......................................................................... - 103 SEMI EQUIPMENT COMMUNICATIONS STANDARD 1 (SECS-I) ......................................................... - 105 - 6. APPENDIX 0 - K&S MODEL POWER SERIES AUTOMATIC BALL BONDER AND K&S MODEL GEN-S AUTOMATIC BALL BONDER SHARED ITEMS ......................................................................................... - 106 6.1 INTRODUCTION ................................................................................................................................. - 106 6.2 K&S MODEL POWER SERIES AUTOMATIC BALL BONDER AND K&S MODEL GEN-S AUTOMATIC BALL BONDER SHARED STATUS VARIABLES ....................................................................................................... - 106 6.3 K&S MODEL POWER SERIES AUTOMATIC BALL BONDER AND K&S MODEL GEN-S AUTOMATIC BALL BONDER SHARED EQUIPMENT CONSTANTS ............................................................................................... - 148 6.4 K&S MODEL POWER SERIES AUTOMATIC BALL BONDER AND K&S MODEL GEN-S AUTOMATIC BALL BONDER SHARED COLLECTION EVENTS .................................................................................................... - 169 6.5 K&S MODEL POWER SERIES AUTOMATIC BALL BONDER AND K&S MODEL GEN-S AUTOMATIC BALL BONDER SHARED ALARMS......................................................................................................................... - 264 6.6 K&S MODEL POWER SERIES AUTOMATIC BALL BONDER AND K&S MODEL GEN-S AUTOMATIC BALL BONDER SHARED DATA VALUES................................................................................................................ - 299 6.7 K&S MODEL POWER SERIES AUTOMATIC BALL BONDER AND K&S MODEL GEN-S AUTOMATIC BALL BONDER GEM COMPLIANCE STATEMENT .................................................................................................. - 301 - 7. APPENDIX 3 - SUMMARY OF SOFTWARE CHANGES ............... - 301 8. APPENDIX 4 - SUMMARY OF DOCUMENT CHANGES ............... - 308 9. APPENDIX 5 – KNOWN ISSUES ...................................................... - 309 10. APPENDIX 6 – SAMPLE TRANSACTIONS AND SCENARIOS - 309 10.1 COMMUNICATIONS ............................................................................................................................ - 309 Enable Communications ........................................................................................................ - 309 Equipment Test for Host Online ........................................................................................... - 309 10.2 ALARMS ........................................................................................................................................... - 309 Enable All Alarms ................................................................................................................. - 309 Equipment Generated Alarm ................................................................................................ - 310 10.3 COLLECTION EVENTS AND REPORTS ............................................................................................... - 310 Disable All Collection Events................................................................................................. - 310 Delete All Reports .................................................................................................................. - 310 Delete Specific Reports .......................................................................................................... - 310 Unlink All Reports Linked to Specific Collection Events ..................................................... - 311 Define Reports ....................................................................................................................... - 313 Link Reports to Collection Events ......................................................................................... - 314 Enable Specific Collection Events ......................................................................................... - 316 10.4 EQUIPMENT STATUS ......................................................................................................................... - 316 Host Request for Selected Status Variable Values ................................................................ - 316 Event Report From Equipment ............................................................................................. - 317 Page vi of 321 Sep 18, 2020 Rev 4.1 Kulicke & Soffa™ SECS/GEM Interface for Ball Bonders Bonder software version x-xx-x-472-series Table of Contents 10.5 DATA SET T RANSFER ....................................................................................................................... - 317 Open Data Set To Upload File ............................................................................................... - 317 Open Data Set to Download File ........................................................................................... - 319 - Page vii of 321 Sep 18, 2020 Rev 4.1 Kulicke & Soffa™ SECS/GEM Interface for Ball Bonders Bonder software version x-xx-x-472-series Figures and Tables Figure 1 – Corresponding Equipment Software .................................................................................. - 12 Figure 2 - Host-Originated Transactions ............................................................................................ - 14 Figure 3 - Equipment-Originated Transactions ................................................................................... - 15 Figure 4 - SML Data Types vs. SEMI E5 Item Format Codes ............................................................ - 16 Figure 5 – Data Types ....................................................................................................................... - 24 Figure 6 - GEM Communications State Model .................................................................................. - 51 Figure 7 – Communications State Transitions .................................................................................... - 52 Figure 8 – Scenario: Host Attempts to Establish Communications ..................................................... - 53 Figure 9 – Scenario: Host-Initiated Are You There ............................................................................ - 53 Figure 10 – Scenario: Equipment-Initiated Are You There ................................................................. - 53 Figure 11 - GEM Control State Model ............................................................................................... - 54 Figure 12 – Control State Transitions................................................................................................. - 55 Figure 13 – Scenario: Operator Actuates ON-LINE Switch and Host Accepts .................................... - 56 Figure 14 – Scenario: Operator Actuates ON-LINE Switch and Host Denies...................................... - 56 Figure 15 – Scenario: Request or Delete Spooled Data....................................................................... - 56 Figure 16 – Scenario: Operator Sets Switch from LOCAL to REMOTE............................................. - 56 Figure 17 – Scenario: Operator Sets Switch from REMOTE to LOCAL............................................. - 56 Figure 18 – Scenario: Host Sets Equipment OFF-LINE ..................................................................... - 56 Figure 19 – Scenario: Host Sets Equipment ON-LINE ....................................................................... - 57 Figure 20 - K&S Model Power Series Automatic Ball Bonder and K&S Model Gen-S Automatic Ball Bonder ........................................................................................................................................ - 57 Figure 21 – State Changes for Process Model. ................................................................................... - 58 Figure 22 – Scenario: Collection Event Occurs on the Equipment ...................................................... - 59 Figure 23 – Scenario: Host Requests Collection Event Report............................................................ - 59 Figure 24 – Scenario: Collection Event Report Setup ......................................................................... - 59 Figure 25 – Scenario: Host Requests Report ...................................................................................... - 60 Figure 26 – Scenario: Host Requests Equipment Status Report .......................................................... - 60 Figure 27 – Scenario: Host Requests Equipment Status Namelist ....................................................... - 60 Figure 28 – Scenario: Host Enables or Disables Alarm ...................................................................... - 60 Figure 29 – Scenario: Upload Alarm Information .............................................................................. - 60 Figure 30 – Scenario: Alarm Occurrence Deleted By Equipment ....................................................... - 60 Figure 31 – Scenario: Host Sends Remote Command to Equipment ................................................... - 60 Figure 32 – Scenario: Host Sends New Equipment Constant Value to the Host .................................. - 70 Figure 33 – Scenario: Host Request Equipment Constant Value from Equipment ............................... - 70 Figure 34 – Scenario: Host Requests Equipment Constants Namelist ................................................. - 70 Figure 35 – Scenario: Host Requests Deletion of Process Program ..................................................... - 70 Figure 36 – Scenario: Host Initiated Process Program Upload. ........................................................... - 71 Figure 37 – Scenario: Host Initiated PP Upload using PP_PREP remote command. ........................... - 72 Figure 38 – Scenario: Equipment Initiated Process Program Download.............................................. - 72 Figure 39 – Scenario: Process Program Directory Request ................................................................. - 72 Figure 40 – Scenario: Host-Initiated Process Program Download. ...................................................... - 73 Figure 41 – Scenario: Equipment-Initiated Process Program Upload - Unformatted ........................... - 73 Figure 42 – Scenario: Host Sends Information to Equipment’s Display Device .................................. - 73 Figure 43 – Scenario: Host Sends Multi-block Message to Equipment Display .................................. - 74 Figure 44 – Scenario: Message Fault Due to Unrecognized Device ID ............................................... - 92 Figure 45 – Scenario: Message Fault Due to Unrecognized Stream Type ........................................... - 92 Figure 46 – Scenario: Message Fault Due to Unrecognized Function Type ........................................ - 92 Page viii of 321 Sep 18, 2020 Rev 4.1 Kulicke & Soffa™ SECS/GEM Interface for Ball Bonders Bonder software version x-xx-x-472-series Figures and Tables Figure 47 – Scenario: Message Fault Due to Illegal Data Format ....................................................... - 92 Figure 48 – Scenario: Message Fault Due to Transaction Timer Timeout ........................................... - 92 Figure 49 - GEM Spooling State Model ............................................................................................. - 93 Figure 50 – Scenario: Host Defines Set of Messages to be Spooled .................................................... - 94 Figure 51 – Scenario: Host Defines Maximum Number of Messages to be Sent ................................. - 94 Figure 52 – Scenario: Request and Delete Spooled Data .................................................................... - 95 Figure 53 – AGV/OHT Action .......................................................................................................... - 95 Figure 54 – Host Defineable Operator Entry #1 Dialog Items............................................................. - 98 Figure 55 – Host Defineable Operator Entry #2 Dialog Items............................................................. - 99 Figure 56 - HSMS Protocol Parameters ........................................................................................... - 104 Figure 57 - SECS-I Protocol Parameters .......................................................................................... - 105 Figure 58 – K&S Model Power Series Automatic Ball Bonder and K&S Model Gen-S Automatic Ball Bonder Shared Status Variables ................................................................................................. - 148 Figure 59 – K&S Model Power Series Automatic Ball Bonder and K&S Model Gen-S Automatic Ball Bonder Shared Equipment Constants ......................................................................................... - 168 Figure 60 – K&S Model Power Series Automatic Ball Bonder and K&S Model Gen-S Automatic Ball Bonder Shared Collection Events ............................................................................................. - 263 Figure 61 – K&S Model Power Series Automatic Ball Bonder and K&S Model Gen-S Automatic Ball Bonder Shared Alarms .............................................................................................................. - 299 Figure 62 – K&S Model Power Series Automatic Ball Bonder and K&S Model Gen-S Automatic Ball Bonder Shared Data Values ....................................................................................................... - 299 Figure 63 – K&S Model Power Series Automatic Ball Bonder and K&S Model Gen-S Automatic Ball Bonder GEM Compliance Statement ......................................................................................... - 301 - Page ix of 321 Sep 18, 2020 Rev 4.1 Kulicke & Soffa™ SECS/GEM Interface for K&S Ball Bonders Bonder software version x-xx-x-472-series 1. General Information This document incorporates the SECS-II Standard Form specified in section 8 of SEMI E5 and complies with the documentation requirements of SEMI E30. K&S Model Power Series Automatic Ball Bonder and K&S Model Gen-S Automatic Ball Bonder SECS messaging is described herein. Appendix 0 contains tables of status variables, equipment constants, collection events, alarms, and data values which are shared by K&S Model Power Series Automatic Ball Bonder and K&S Model Gen-S Automatic Ball Bonder. 1.1 Introduction This document describes the SEMI Equipment Communications Standard (SECS) communications interface for the K&S Model Power Series Automatic Ball Bonder and K&S Model Gen-S Automatic Ball Bonder. It is intended for use by computer-integrated manufacturing (CIM) personnel who wish to monitor and control the equipment via a remote host computer. A working knowledge of the equipment and the following Semiconductor Equipment and Materials International (SEMI) Equipment Automation/Software Standards is assumed: • SEMI E4-91 Equipment Communications Standard 1 Message Transfer (SECS-I). • SEMI E5-96 Equipment Communications Standard 2 Message Content (SECS-II). • SEMI E30-95 Generic Model for Communications and Control of SEMI Equipment (GEM). • SEMI E37-95 High-Speed SECS Message Services (HSMS) Generic Services. • SEMI E37.1-95 High-Speed SECS Message Services Single-Session Mode (HSMS-SS). • SEMI G84-1101 Specification for Strip Map Protocol (Premium Option) • SEMI E142 Protocol for Substrate Mapping (Premium Option) • SEMI E87 Carrier Management (Premium Option) • SEMI E40 Processing Job Management (Premium Option) • SEMI E94 Control Job Management (Premium Option) 1.2 Manufacturer and Product Model K&S Model IConn/IConn PLUS/IConn ProCu/IConn ProCu PLUS/IConn MEM PLUS/RAPID/RAPID Pro/RAPID MEM Automatic Ball Bonder K&S Model ConnX/ConnX PLUS/ConnX-LED/ConnX-LED PLUS/ConnX ELITE/ConnX ELITE RPM/ConnX ELITE Opto/ConnX ELITE Opto RPM/ConnX ELITE VLF/OptoLux/OptoLux VLF Automatic Ball Bonder 1.3 General Description of Equipment Function The K&S Model Power Series Automatic Ball Bonder and K&S Model Gen-S Automatic Ball Bonder series attach wires on semiconductor integrated circuit (IC) devices. The machines process wires by means of a thermosonic bonding process using heat, force and ultrasonic energy to fuse each end of the wire to the device. The machines feature integrated PRS/Video Lead Locator systems and are equipped with automatic material handling systems. Intended Function of Interface The function of the SECS/GEM interface is to allow an external host computer to monitor and control K&S Model Power Series Automatic Ball Bonder and K&S Model Gen-S Automatic Ball Bonder according to specified SECS-II message sets and supported GEM capabilities. Software Version Number Page - 10 - of 321 Sep 18, 2020 Rev 4.1 Kulicke & Soffa™ SECS/GEM Interface for K&S Ball Bonders Bonder software version x-xx-x-472-series Date 03/02/09 BALL BONDER OPERATING SYSTEM SOFTWARE VERSIONS Software Document Model Version Revision # Comments IConnConnx & UltraElite IConnConnx & UltraElite IConn/ConnX/ConnX+/ ConnXLED/ProCu & Ultra/Elite IConn/ConnX/ConnX+/ ConnXLED/ProCu & Ultra/Elite IConn/IConn+/ ConnX/ConnX+/ ConnXLED/ProCu/ ProCu+ IConn/IConn+/ ConnX/ConnX+/ ConnXLED/ProCu/ ProCu+ IConn/IConn+/ ConnX/ConnX+/ ConnXLED/ ProCu/ ProCu+ IConn/IConn+/ ConnX/ConnX+/ ConnXLED/ ConnXLED+ ProCu/ ProCu+ x-xx-x-41A-1 Rev 1.9 See Appendix 3 for change details x-xx-x-43A-1 Rev 2.0 See Appendix 3 for change details x-xx-x-446 Rev 2.1 See Appendix 3 for change details x-xx-x-451 Rev 2.2 See Appendix 3 for change details x-xx-x-454 Rev 2.3 See Appendix 3 for change details x-xx-x-455 Rev 2.4 See Appendix 3 for change details x-xx-x-456 Rev 2.5 See Appendix 3 for change details x-xx-x-457 Rev 2.6 See Appendix 3 for change details 07/21/15 IConn/IConn+/ ConnX/ConnX+/ ConnXLED/ ProCu/ ProCu+ x-xx-x-458 Rev 2.7 See Appendix 3 for change details 11/19/15 IConn/IConn+/ ConnX/ConnX+/ ConnXLED/ ProCu/ ProCu+ x-xx-x-459 Rev 2.8 See Appendix 3 for change details 02/19/16 IConn/IConn+/ ConnX/ConnX+/ ConnXLED/ ProCu/ ProCu+ x-xx-x-460 Rev 2.9 See Appendix 3 for change details 07/20/16 IConn/IConn+/ ConnX/ConnX+/ ConnXLED/ ProCu/ ProCu+ x-xx-x-461 Rev 3.0 See Appendix 3 for change details 12/27/16 IConn/IConn+/ ConnX/ConnX+/ ConnXLED/ ProCu/ ProCu+ x-xx-x-462 Rev 3.1 See Appendix 3 for change details 04/20/17 IConn/IConn+/ ConnX/ConnX+/ ConnXLED/ ProCu/ ProCu+ IConn/IConn+/ ConnX/ConnX+/ ConnXLED/ ProCu/ ProCu+/ConnXLED+/ConnX ELITE x-xx-x-463 Rev 3.2 See Appendix 3 for change details x-xx-x-464 Rev 3.3 See Appendix 3 for change details 09/16/10 02/10/12 05/08/13 01/10/14 06/12/14 09/22/14 01/15/15 09/25/17 Page - 11 - of 321 Sep 18, 2020 Rev 4.1 Kulicke & Soffa™ SECS/GEM Interface for K&S Ball Bonders Bonder software version x-xx-x-472-series Date 03/15/18 09/10/18 01/04/19 05/28/19 08/23/19 03/19/20 05/19/20 09/18/20 BALL BONDER OPERATING SYSTEM SOFTWARE VERSIONS Software Document Model Version Revision # Comments IConn/IConn+/ ConnX/ConnX+/ ConnXLED/ ProCu/ ProCu+/ConnXLED+/ConnX ELITE/ Rapid Pro/OptoLUX IConn/IConn+/ ConnX/ConnX+/ ConnXLED/ ProCu/ ProCu+/ConnXLED+/IConn MEM Plus/ConnX ELITE/ Rapid/Rapid Pro/OptoLUX/ConnX ELITE Opto IConn+/ConnX+/ ProCu+/ConnXLED+/IConn MEM Plus/ConnX ELITE/ Rapid/Rapid Pro/OptoLUX/ConnX ELITE Opto IConn+/ConnX+/ ProCu+/ConnXLED+/IConn MEM Plus/ConnX ELITE/ Rapid/Rapid Pro/OptoLUX/ConnX ELITE Opto IConn+/ConnX+/ ProCu+/ConnXLED+/IConn MEM Plus/ConnX ELITE/ Rapid/Rapid Pro/OptoLUX/ConnX ELITE Opto IConn+/ConnX+/ ProCu+/ConnXLED+/IConn MEM Plus/ConnX ELITE/ Rapid/Rapid Pro/OptoLUX/ConnX ELITE Opto IConn+/ConnX+/ ProCu+/ConnXLED+/IConn MEM Plus/ConnX ELITE/ Rapid/Rapid Pro/OptoLUX/ConnX ELITE Opto/OptoLux VLF IConn+/ConnX+/ ProCu+/ConnXLED+/IConn MEM Plus/ConnX ELITE/ Rapid/Rapid Pro/OptoLUX/ConnX ELITE Opto/OptoLux VLF x-xx-x-465 Rev 3.4 See Appendix 3 for change details x-xx-x-466 Rev 3.5 See Appendix 3 for change details x-xx-x-467 Rev 3.6 See Appendix 3 for change details x-xx-x-468 Rev 3.7 See Appendix 3 for change details x-xx-x-469 Rev 3.8 See Appendix 3 for change details x-xx-x-470 Rev 3.9 See Appendix 3 for change details x-xx-x-471 Rev 4.0 See Appendix 3 for change details x-xx-x-472 Rev 4.1 See Appendix 3 for change details Figure 1 – Corresponding Equipment Software Page - 12 - of 321 Sep 18, 2020 Rev 4.1 Kulicke & Soffa™ SECS/GEM Interface for K&S Ball Bonders Bonder software version x-xx-x-472-series 2. SECS-II Message Summary 2.1 Host-Originated Transactions The following table summarizes the primary SECS-II messages understood by the equipment and the associated secondary replies (where applicable): Page - 13 - of 321 Sep 18, 2020 Rev 4.1 Kulicke & Soffa™ SECS/GEM Interface for K&S Ball Bonders Bonder software version x-xx-x-472-series Host to Equipment Messages Primary SX,F0 Abort Transaction (SXF0) Secondary - S1,F1 Are You There Request (R) S1,F3 Selected Equipment Status Request (SSR) S1,F11 Status Variable Namelist Request (SVNR) S1,F13 Establish Communications Request (CR) S1,F15 Request OFF-LINE (ROFL) S1,F17 Request ON-LINE (RONL) S2,F13 Equipment Constant Request (ECR) S2,F15 New Equipment Constant Send (ECS) S2,F17 Date and Time Request (DTR) S2,F23 Trace Initialize Send (TIS) S2,F29 Equipment Constant Namelist Request (ECNR) S2,F31 Date and Time Set Request (DTS) S2,F33 Define Report (DR) S2,F35 Link Event Report (LER) S2,F37 Enable/Disable Event Report (EDER) S2,F39 Multi-Block Inquire (MBI) S2,F41 Host Command Send (HCS) S2,F43 Reset Spooling Streams and Functions (RSSF) S2,F45 Define Variable Limit Attributes (DVLA) S1,F2 On Line Data (D) S1,F4 Selected Equipment Status Data (SSD) S1,F12 Status Variable Namelist Reply (SVNRR) S1,F14 Establish Communications Request Acknowledge (CRA) S1,F16 OFF-LINE Acknowledge (OFLA) S1,F18 ON-LINE Acknowledge (ONLA) S2,F14 Equipment Constant Data (ECD) S2,F16 New Equipment Constant Acknowledge (ECA) S2,F18 Date and Time Data (DTD) S2,F24 Trace Initialize Acknowledge (TIA) S2,F30 Equipment Constant Namelist (ECN) S2,F32 Date and Time Set Acknowledge (DTA) S2,F34 Define Report Acknowledge (DRA) S2,F36 Link Event Report Acknowledge (LERA) S2,F38 Enable/Disable Event Report Acknowledge (EERA) S2,F40 Multi-Block Grant (MBG) S2,F42 Host Command Acknowledge (HCA) S2,F44 Reset Spooling Acknowledge (RSA) S2,F47 Variable Limit Attribute Request (VLAR) S4,F19 Transfer Job Create (TJ) S4,F21 Transfer Job Command (TC) S4,F27 Handoff Ready (HR) S4,F33 Handoff Verified (HV) S2,F46 Variable Limit Attribute Acknowledge (VLAA) S2,F48 Variable Limit Attributes Send (VLAS) S4,F20 Transfer Job Acknowledge (TJA) S4,F22 Transfer Command Acknowledge (TCA) - S5,F3 Enable/Disable Alarm Send (EAS) S5,F5 List Alarms Request (LAR) S5,F4 Enable/Disable Alarm Acknowledge (EAA) S5,F6 List Alarms Data (LAD) S6,F15 Event Report Request (ERR) S6,F19 Individual Report Request (IRR) S6,F23 Request Spooled Data (RSD) S6,F16 Event Report Data (ERD) S6,F20 Individual Report Data (IRD) S6,F24 Request Spooled Data Acknowledgment Send (RSDAS) S7,F1 Process Program Load Inquire (PPI) S7,F3 Process Program Send (PPS) S7,F5 Process Program Request (PPR) S7,F17 Delete Process Program Send (DPS) S7,F2 Process Program Load Grant (PPG) S7,F4 Process Program Acknowledge (PPA) S7,F6 Process Program Data (PPD) S7,F18 Delete Process Program Acknowledge (DPA) S7,F20 Current EPPD Data (RED) S7,F19 Current EPPD Request (RER) S10,F3 Terminal Display, Single (VTN) S10,F5 Terminal Display, Multi-Block (VTN) S14,F1 GetAttr Request (GAR) Figure 2 - Host-Originated Transactions S10,F4 Terminal Display, Single Acknowledge (VTA) S10,F6 Terminal Display, Multi-Block Acknowledge (VMA) S14,F2 GetAttr Data (GAD) Page - 14 - of 321 Sep 18, 2020 Rev 4.1 Kulicke & Soffa™ SECS/GEM Interface for K&S Ball Bonders Bonder software version x-xx-x-472-series 2.2 Equipment-Originated Transactions The following table summarizes the primary SECS-II messages originated by the equipment and the expected secondary replies (where applicable): Equipment to Host Messages Primary Secondary SX,F0 Abort Transaction (SXF0) S1,F1 Are You There Request (R) S1,F13 Establish Communications Request (CR) S1,F2 On Line Data (D) S1,F14 Establish Communications Request Acknowledge (CRA) S2,F17 Date and Time Request (DTR) S2,F18 Date and Time Data (DTD) S4,F23 Transfer Job Alert (TJA) S4,F27 Handoff Ready (HR) S4,F33 Handoff Verified (HV) S4,F24 Transfer Alert Acknowledge (TLA) - S5,F1 Alarm Report Send (ARS) S5,F2 Alarm Report Acknowledge (ARA) S6,F1 Trace Data Send (TDS) S6,F5 Multi-Block Data Send Inquire (MBI) S6,F11 Event Report Send (ERS) S6,F2 Trace Data Acknowledge (TDA) S6,F6 Multi-Block Grant (MBG) S6,F12 Event Report Acknowledge (ERA) S7,F1 Process Program Load Inquire (PPI) S7,F3 Process Program Send (PPS) S7,F5 Process Program Request (PPR) S7,F2 Process Program Load Grant (PPG) S7,F4 Process Program Acknowledge (PPA) S7,F6 Process Program Data (PPD) S9,F1 Unrecognized Device ID (UDN) S9,F3 Unrecognized Stream Type (USN) S9,F5 Unrecognized Function Type (UFN) S9,F7 Illegal Data (IDN) S9,F9 Transaction Timer Timeout (TTN) S9,F11 Data Too Long (DLN) S9,F13 Conversation Timeout (CTN) (Note: Not currently used) - S10,F1 Terminal Request (TRN) S14,F1 GetAttr Request (GAR) Figure 3 - Equipment-Originated Transactions S10,F2 Terminal Request Acknowledge (TRA) S14,F2 GetAttr Data (GAD) Page - 15 - of 321 Sep 18, 2020 Rev 4.1 Kulicke & Soffa™ SECS/GEM Interface for K&S Ball Bonders Bonder software version x-xx-x-472-series 3. SECS-II Message Detail 3.1 Data Items Complete details of all SECS-II messages supported by the equipment are provided in this section. For enhanced readability, messages are documented using SECS Message Language (SML) format. Data item names are presented as comments within each message description. SML data item types map to SEMI E5 item header format codes as follows: SML DATA TYPES VS. SEMI E5 ITEM FORMAT CODES SML Data Item Type SEMI E5 (Octal) L List 00 B Binary 10 BL Boolean 11 A ASCII 20 J JIS-8 21 I8 Signed 8-byte integer 30 I1 Signed 1-byte integer 31 I2 Signed 2-byte integer 32 I4 Signed 4-byte integer 34 F8 8-byte floating point 40 F4 4-byte floating point 44 U8 Unsigned 8-byte integer 50 U1 Unsigned 1-byte integer 51 U2 Unsigned 2-byte integer 52 U4 Unsigned 4-byte integer 54 V Variable N/A Figure 4 - SML Data Types vs. SEMI E5 Item Format Codes Data Dictionary This section describes the data items used in the SECS-II messages supported by the equipment. Page - 16 - of 321 Sep 18, 2020 Rev 4.1 Kulicke & Soffa™ SECS/GEM Interface for K&S Ball Bonders Bonder software version x-xx-x-472-series Data Types Name ACKC5 Format B[1] Where Used S5F4 S5F2 ACKC6 B[1] S6F12 ACKC7 B[1] S7F4 S7F18 ACKC10 B[1] S10F4, F6 ACKC13 B S13F2, S13F4, S13F6, S13F8 ALCD B[1] S5F6 Description Stream 0 >0 1-63 Stream 0 >0 1-63 Stream 0 1 2 4 5 5 acknowledge code. = accepted = error, not accepted = reserved 6 acknowledge code. = Accepted = Error, not accepted = Reserved 7 acknowledge code. = Accepted = Permission not granted (busy) = Length error = PPID not found = Mode unsupported (equipment not under remote control) 6-63 = Reserved Stream 10 acknowledge code. 0 = Accepted for display 1 = Message will not be displayed 2 = Terminal not available 3-63 = Reserved Acknowledge code 0 = O.K. 1 = ERROR: Try later. 2 = ERROR: Unknown Data Set Name. 3 = ERROR: Illegal Checkpoint value. 4 = ERROR: Too many open Data Sets. 5 = ERROR: Data set open too many times. 6 = ERROR: No open Data set 7 = ERROR: Cannot Continue 8 = ERROR: End of Data 9 = ERROR: Handle in Use. 10 = ERROR: Pending Transaction. Alarm code. bit 8 = 1 means alarm set bit 8 = 0 means alarm cleared bits 7 - 1 is alarm category code: 0 = Not used 1 = Personal safety 2 = Equipment safety 3 = control warning 4 = Parameter control error 5 = Irrecoverable error 6 = Equipment status warning 7 = Attention flags 8 = Data integrity >8 = Other categories 9-63 = Reserved Page - 17 - of 321 Sep 18, 2020 Rev 4.1 Kulicke & Soffa™ SECS/GEM Interface for K&S Ball Bonders Bonder software version x-xx-x-472-series Data Types Name ALED Format B[1] Where Used S5F3 ALID U2[1] ALTX CEED A[40] BL[1] S5F3, F5, F6 S5F6 S2F37 CEID U2[1] COMMACK B[1] CKPNT CPACK 54 B[1] S13F3,F6 CPNAME A[40] CPVAL DATAID V U2[1] S2F41, S2F42 S2F41 S2F33, F35, F45; S6F5, F11, F16 DATALENGTH U4[1] DRACK B[1] DSNAME A S13F1, S13F2 S13F3, S13F4 DSPER A[6] S2F23 S2F35, F37; S6F11, F15 S1F14 S2F42 S2F39; S6F5. S2F34 Description Alarm enable/disable code. bit 8 = 1 means enable alarm bit 8 = 0 means disable alarm Alarm identification. Alarm text, limited to 40 characters. Collection event enable/disable code. FALSE = Disable TRUE = Enable Collection event ID. Communications acknowledge code. 0 = Accepted 1 = Denied, try again 2-63 = Reserved Checkpoint as defined by the sending system Command parameter acknowledge code. 1 = Parameter name does not exist 2 = Illegal value specified 3 = Illegal format specified for CPVAL 4-63 = Reserved Command parameter name. Command parameter value. Data ID. In SECS-I environments, the equipment uses the DATAID to match a multi-block S2F33,F35,F45 with the corresponding S2F39/40 multi-block inquire/grant. Therefore, the host should only use a non-zero DATAID when the S2F33,F35,F45 message will be multi-block. If the S2F33,35,45 message is single-block, the DATAID must be 0. In HSMS environments, messages are always a single block and the DATAID must always be 0. Total bytes to be sent. Define report acknowledge code. 0 = Accepted 1 = Denied. Insufficient space 2 = Denied. Invalid format 3 = Denied. At least one RPTID already defined 4 = Denied. At least one VID does not exist 5 = DATAID Not found or other internal error 6-63 = Reserved Data Set Name - logical name that has meaning to both the bonder and the host. • PACKAGE_INF - associated with the data file (PACKAGE.INF) that contains requirements for installing bonder software. • PACKAGE_TAR - associated with the files needed to install bonder software. Data sample period, format hhmmss Page - 18 - of 321 Sep 18, 2020 Rev 4.1 Kulicke & Soffa™ SECS/GEM Interface for K&S Ball Bonders Bonder software version x-xx-x-472-series Data Types Name DVVAL EAC Format V B[1] Where Used S6F11 S2F16 ECDEF ECID V U2[1] ECMAX ECMIN ECNAME ECV V V A[40] V EQNAME ERACK A[40] B[1] S2F30 S2F13, F15, F29, F30 S2F30 S2F30 S2F30 S2F14, F15 S4F27 S2F38 FCNID U1[1] FILDAT GRANT B B[1] S2F43, F44 S13F6 S2F40 GRANT6 B[1] S6F6 HANDLE U2 HCACK B[1] S13F3, 13F4, S13F5, 13F6, S13F7, S1F8 S2F42 HOACK BL[1] S4F33 Description Data value. Equipment acknowledge code. 0 = Acknowledge 1 = Denied. At least one constant does not exist 2 = Denied. Busy 3 = Denied. At least one constant out of range 4-63 = Reserved Equipment constant default value. Equipment constant ID. Equipment constant maximum value. Equipment constant minimum value. Equipment constant name. Equipment constant value. Equipment name. Note: Not used, always set to empty string ''. Enable/disable event report acknowledge code. 0 = Accepted 1 = Denied. At least CEID does not exist 2-63 = Reserved Function identification. Data from the data set. Grant code. 0 = Positive response, load OK 1 = Busy, try again 2 = No space 3 = Duplicate name 4-63 = Reserved Permission to send. 0 = Permission granted 1 = Busy, try again 2 = Not interested 3-63 = Reserved Logical unit or channel. Used to keep track of the state of a particular data set and instance of OPEN between the host and the bonder. Host command parameter acknowledge code. 0 = Acknowledge; command has been performed 1 = Command does not exist 2 = Cannot perform now 3 = At least one parameter is invalid 4 = Acknowledge; command will be performed 5 = Rejected; already in desired condition 6 = Unable to perform, Internal error occurred. 7-63 = Reserved Status of corresponding handoff activity. FALSE = Fail TRUE = Success Page - 19 - of 321 Sep 18, 2020 Rev 4.1 Kulicke & Soffa™ SECS/GEM Interface for K&S Ball Bonders Bonder software version x-xx-x-472-series Data Types Name LENGTH LIMITACK Format U4[1] B[1] Where Used S7F1 S2F46 LIMITID B[1] S2F45, F46, F48 LIMITMAX V S2F48 LIMITMIN V S2F48 LOWERDB V LRACK B[1] S2F45, F46, F48 S2F36 LVACK B[1] S2F46 MDLN A[6] MHEAD B[10] OFLACK B[1] S1F2, F13, F14 S9F1, F3, F5, F7 S1F16 ONLACK B[1] S1F18 PPBODY B[N] S7F3, F6 Description Process program body (PPBODY) length, in bytes. Variable limit attribute set acknowledge code. 0 = Accepted 1 = LIMITID does not exist 2 = UPPERDB > LIMITMAX 3 = LOWERDB < LIMITMIN 4 = UPPERDB < LOWERDB 5 = Illegal UPPERDB or LOWERDB format 6 = ASCII value cannot be translated to numeric 7 = Duplicate LIMITID 8 = Other error 9-63 = Reserved The identifier of a specific limit in a set of limits.(as defined by UPPERDB and LOWERDB) for a variable to which the limits refer. The maximum value for the limit values of a specific variable. The format must match that of the referenced variable. The minimum value for the limit values of a specific variable. The format must match that of the referenced variable. The lower boundary of the deadband of a limit. The value applies to a single limit (LIMITID) for a specified VID. Link report acknowledge code. 0 = Accepted 1 = Denied. Insufficient space 2 = Denied. Invalid format 3 = Denied. At least one CEID link already defined 4 = Denied. At least one CEID does not exist 5 = Denied. At least one RPTID does not exist 6 = Denied. Invalid DATAID or internal runtime error 7-63 = Reserved Variable limit definition acknowledge code. 0 = Accepted 1 = Variable does not exist 2 = Variable has no limits capability 3 = Variable repeated in message 4 = Limit value error as described in LIMITACK 5-63 = Reserved Model number; a constant ASCII field. Content is an equipmentspecific EC. The header of a message containing an error (SECS-I format). The block number in MHEAD will be a constant 0, regardless of the message transport protocol in use. OFF-LINE request acknowledge code. 0 = OFF-LINE acknowledge 1-63 = Reserved ON-LINE request acknowledge code. 0 = ON-LINE accepted 1 = ON-LINE not allowed 2 = Equipment already ON-LINE 3-63 = Reserved Process program body. Maximum N (approximate) = 232 (HSMS) or 7.9Mb (SECS-I). Page - 20 - of 321 Sep 18, 2020 Rev 4.1 Kulicke & Soffa™ SECS/GEM Interface for K&S Ball Bonders Bonder software version x-xx-x-472-series Data Types Name PPGNT Format B[1] Where Used S7F2 PPID A[80] S7F1, F3, F5, F6, F17, F20 RCMD A[20] S2F41 READLEN U4 S13F5 RECLEN REPGSZ RPTID 3(),5() RSDA B[1] S13F4 S2F23 S2F33, F35; S6F11, F16 S6F24 RSDC U1[1] S6F23 RSPACK B[1] S2F44 RTYPE U2 S13F4 SHEAD B[10] S9F9 SMPLN SOFTREV <U,I> A[6] S6F1 S1F2, F13, F14 U4[1] U2[1] Description Process program grant status. 0 = OK 1 = Already have 2 = No space 3 = Invalid PPID 4 = Busy, try later 5 = Will not accept 6 = other errors 7 = No PFF file is installed (Customization) 8-63 = Reserved Process program ID. This is the name of the process program: If PPSelectMode = 0, use standard DOS compatible “8.3” format. If PPSelectMode = 1, use 80 characters maximum. The host system must first determine the process program select mode of the equipment by requesting the PPSelectMode status variable (SVID3106). Currently, the process program select mode can only be set manually at the equipment. Remote command code. Case is not significant and dashes ‘-‘ may be substituted for underscores ‘_’. See section 4.6 for more information regarding remote commands. Maximum number of data bytes that the bonder is able to process at one time. Note: 20% of available contiguous RAM is assigned to READLEN. Maximum length of a Discrete record Reporting group size. Report ID. Request spool data acknowledge. 0 = OK 1 = Denied, busy try later 2 = Denied, spooled data does not exist 3-63 = Reserved Request spool data code. 0 = Transmit spooled messages 1 = Purge spooled messages 2-63 = Reserved Reset spooling acknowledge. 0 = Acknowledge, spooling setup accepted 1 = Spooling setup rejected 2- 63 = Reserved Type of record. 0 = stream Stored header related to a transaction timer timeout (SECS-I format). The block number in SHEAD will be a constant 0, regardless of the message transport protocol in use. Sample Number The software revision code; a constant ASCII field. Content is an equipment-specific EC. Page - 21 - of 321 Sep 18, 2020 Rev 4.1 Kulicke & Soffa™ SECS/GEM Interface for K&S Ball Bonders Bonder software version x-xx-x-472-series Data Types Name Format Where Used S6F1 S6F24 STIME STRACK A [12] STRID U1[1] SV V SVID U2[1] SVNAME TEXT A[40] A[80] TIAACK B[1] S2F43, F44 S1F4; S6F1 S1F3, F11, F12; S2F23, S2F33 S1F12 S10F3, F5 S2F24 TIACK B[1] S2F32 TID B[1] S10F3, F5 TIME A[12] TOTSMP TRACK U4[1] BL[1] S2F18, F31 S2F23 S4F20, F22, F23 TRATOMICID U2[1] S4F20 TRAUTOSTART BL[1] S4F19 TRCMDNAME A[40] S4F21 B[1] Description Sample Time. 12 byte format YYMMDDhhmmss Spool stream acknowledge. 1 = Spooling not allowed for stream (i.e. S1). 2 = Stream unknown. 3 = Unknown function specified for this stream. 4 = Secondary function specified for this stream. Stream identification. Status variable value. Status variable ID. Status variables may include any parameter that can be sampled in time such as temperature or quantity of a consumable. Status variable name. A single line of characters. Trace acknowledge code. 0 = Accepted 1 = Too many SVIDs 2 = No more traces allowed 3 = Invalid period 4 = Rejected 5-63 = Reserved Time acknowledge code. 0 = OK 1 = Error, not done 2-63 = Reserved Terminal number. 0 = Display message on the equipment’s display device after the Msg button is selected. 1 = Display message directly on the equipment’s display device when received. Time of day, 12 bytes, format yymmddhhmmss. Total samples to be made. Status of related transfer activity. FALSE = Fail TRUE = Success Equipment assigned identifier for an atomic transfer. Value expected to be equal to TRLINK in S4F19. For each atomic transfer, this data item tells the equipment if it should automatically start the handoff when ready (=TRUE) or wait for the host's "Start Handoff" command (=FALSE) following setup. This data item only affects the primary transfer. Note: Always set to TRUE; equipment awaits host start command. Identifier of the transfer job related command to be executed. Possible values: "ABORT" Page - 22 - of 321 Sep 18, 2020 Rev 4.1 Kulicke & Soffa™ SECS/GEM Interface for K&S Ball Bonders Bonder software version x-xx-x-472-series Data Types Name TRDIR Format U1[1] Where Used S4F19 TRID U2[1] TRJOBID B[1] TRJOBMS U1[1] S2F23, S6F1 S4F20, F21, F23 S4F23 TRJOBNAME A[40] TRLINK U2[1] TRLOCATION U2[1] TROBJNAME A[40] TROBJTYPE U2[1] TRPORT U1[1] TRPTNR A[40] S4F19, F27 TRPTPORT U2[1] S4F19, F27 TRRCP A[40] S4F19 TRROLE U1[1] S4F19, F27 TRTIMEOUT U2[1] TRTYPE U1[1] S4F19, F27 UNITS A[N] UPPERDB V S1F12; S2F30, F48 S2F45, F46, F48 S4F19, F23 S4F19, F27, F33 S4F19, F27 S4F19, F23, F27 S4F19, F27 S4F19, F27 Description Direction of handoff as seen from the equipment. 1 = Send material. 2 = Receive material. Trace request ID. Equipment assigned identifier for the transfer job. Note: Always set to 1. Milestone for a transfer job (e.g. started or complete). 1 = Transfer job started. 2 = Transfer job completed Host assigned identifier for the transfer job. Note: Not used, always set to empty string ''. Common identifier for the atomic transfer used by the transfer partners to confirm that they are working on the same hostdefined task. Identifier of the material location involved with the transfer. Note: Not used; always set to 0. Identifier for the material (transfer object) to be transferred. Type of object to be transferred. 0 = Magazine Identifier of the equipment port to be used for the handoff. 1 = Port 1: preprocess load port 2 = Port 2: preprocess unload port 3 = Port 3: postprocess load port 4 = Port 4: postprocess unload port Name of the equipment that will serve as the other transfer partner for this atomic transfer. This corresponds to EQNAME. Note: Not used; always set to empty string ''. Identifier of the transfer partner's port to be used for the transfer. Note: Not used; always set to 0. Name of the transfer recipe for this transfer. Note: Not used; always set to empty string ''. Tells whether the equipment is to be an active or passive (primary / secondary) participant in the transfer. 1 = Primary transfer partner 2 = Secondary transfer partner Note: Equipment is the Secondary transfer partner (2). Maximum time to wait in state "AWAITING XFR PARTNER" in seconds. Tells whether the equipment is to be an active or passive participant in the transfer. 1 = Active (Track Robot) 2 = Passive (Equipment) Units identifier. The upper boundary of the deadband of a limit. The value applies to a single limit (LIMITID) for a specified VID. Page - 23 - of 321 Sep 18, 2020 Rev 4.1 Kulicke & Soffa™ SECS/GEM Interface for K&S Ball Bonders Bonder software version x-xx-x-472-series Data Types Name VID Format U2[1] VLAACK B[1] Where Used S2F45, F46, F47, F48 S2F46 Description Variable ID. Variable limit attribute acknowledge code. 0 = Accepted 1 = Limit attribute definition error 2 = Cannot perform now, equipment busy 3 = Other equipment-specific error 4-63 = Reserved Figure 5 – Data Types Page - 24 - of 321 Sep 18, 2020 Rev 4.1 Kulicke & Soffa™ SECS/GEM Interface for K&S Ball Bonders Bonder software version x-xx-x-472-series Status Variables The status variables (SVs) and associated status variable ID (SVID) provided by the equipment are described in the equipment specific appendices. Equipment Constants The equipment constant values (ECVs) and associated equipment constant IDs (ECIDs) provided by the equipment are described in the equipment specific appendices. Collection Events The collection events (CEs) and associated collection event ID (CEID) provided by the equipment are described in the equipment specific appendices. Alarms The Alarms and associated Alarm IDs (ALID) provided by the equipment are described in the equipment specific appendices. 3.2 Host-Originated Transactions This section details the primary SECS-II messages understood by the equipment and the associated secondary replies (where applicable). Sx,F0 Abort Transaction (SxF0) Usage: S,H->E Description: Used with all streams in lieu of an expected message to abort a transaction. Structure: Header-only. S1,F1 Are You There Request (R) Usage: S,H->E,reply Description: Used to test whether the equipment is on-line. A function 0 response to S1,F1 indicates SECS communication is inoperative (equivalent to a T3 (reply) timeout at the host). While communications are established, the host may issue this message at any time to test the SECS link. Structure: Header-only. S1,F2 On Line Data (D) Usage: S,H<-E Description: Equipment reply to host-originated S1,F1. Structure: <L[2] <A[MAX 6]> <A[MAX 6]> >. * MDLN * SOFTREV S1,F3 Selected Equipment Status Request (SSR) Usage: S,H->E,reply Description: Used to request the values of selected status variables. Structure: <L[MAX N] <U2[1]> * SVID1 . . . <U2[1]> * SVIDN >. Notes: If N=0, then KGem will report all known SVs in ascending SVID order. ECVs may not be requested via this message. The older (alternative) format of this message is not supported. Page - 25 - of 321 Sep 18, 2020 Rev 4.1 Kulicke & Soffa™ SECS/GEM Interface for K&S Ball Bonders Bonder software version x-xx-x-472-series S1,F4 Selected Equipment Status Data (SSD) Usage: S,H<-E Description: Returned by the equipment to report the SV values in the order requested. Structure: <L[MAX N] <V> * SV1 . . . <V> * SVN >. Notes: A zero-length list (<L[0]>) returned for SVi means that SVIDi has not been defined to KGem. S1,F11 Status Variable Namelist Request (SVNR) Usage: S,H->E,reply Description: This message is used by the host to request identification of certain status variables. Structure: <L[MAX N] <U2[1]> * SVID1 . . . <U2[1]> * SVIDN >. Notes: If N=0, then KGem will report all known SVs in ascending SVID order. ECVs may not be requested via this message. S1,F12 Status Variable Namelist Reply (SVNRR) Usage: S,H<-E Description: Returned by the equipment to report the requested SV information. Structure: <L[MAX N] <L[3]1 <U2[1]> * SVID1 <A[MAX 40]> * SVNAME1 <A[MAX N]> * UNITS1 > . . . <L[3]N <U2[1]> <A[MAX 40> <A[MAX N]> Notes: * SVIDN * SVNAMEN * UNITSN > >. A zero-length name and units (<A[0]>) returned for SVi means that SVIDi has not been defined to KGem. S1,F13 Establish Communications Request (CR) Usage: S,H->E,reply Description: Used by the host to attempt to initialize communications with the equipment. Structure: <L[0]>. Page - 26 - of 321 Sep 18, 2020 Rev 4.1 Kulicke & Soffa™ SECS/GEM Interface for K&S Ball Bonders Bonder software version x-xx-x-472-series S1,F14 Establish Communications Request Acknowledge (CRA) Usage: S,H<-E Description: Equipment reply to host-originated S1,F13. Structure: <L[2] <B[1]> * COMMACK <L[2] <A[MAX 6]> * MDLN <A[MAX 32]> * SOFTREV > >. S1,F15 Request OFF-LINE (ROFL) Usage: S,H->E,reply Description: Used by the host to request equipment transition to the OFF-LINE control state. Structure: Header-only. S1,F16 OFF-LINE Acknowledge (OFLA) Usage: S,H<-E Description: OFF-LINE request acknowledge or error. Structure: <B[1]>. * OFLACK S1,F17 Request ON-LINE (RONL) Usage: S,H->E,reply Description: Used by the host to request equipment transition to the ON-LINE control state. Structure: Header-only. S1,F18 ON-LINE Acknowledge (ONLA) Usage: S,H<-E Description: ON-LINE request acknowledge or error. Structure: <B[1]>. * ONLACK S2,F13 Equipment Constant Request (ECR) Usage: S,H->E,reply Description: Used by the host to request current equipment constant values from the equipment. Structure: <L[N] <U2[1]> * ECID1 . . . <U2[1]> * ECIDN >. Notes: SVs may not be requested via this message. The older (alternative) format of this message will not be supported. S2,F14 Equipment Constant Data (ECD) Usage: S,H<-E Description: Equipment response to S2,F13. ECVs are reported in the order requested. Structure: <L[N] <V> * ECV1 . . . <V> * ECVN >. Notes: A zero-length list returned for ECVi means that ECIDi does not exist. S2,F15 New Equipment Constant Send (ECS) Usage: S,H->E,reply Page - 27 - of 321 Sep 18, 2020 Rev 4.1 Kulicke & Soffa™ SECS/GEM Interface for K&S Ball Bonders Bonder software version x-xx-x-472-series Description: Structure: The host directs the equipment to change specific equipment constants. The equipment is responsible for validating new equipment constant values. New values will take effect as soon as possible. <L[N] <L[2]1 <U2[1]> * ECID1 <V> * ECV1 > . . . <L[2]N <U2[1]> * ECIDN <V> * ECVN > >. S2,F16 New Equipment Constant Acknowledge (ECA) Usage: S,H<-E Description: Equipment response to S2,F15. Any error will cause the entire message to be rejected. Partial updates will not be performed. Structure: <B[1]>. * EAC S2,F17 Date and Time Request (DTR) Usage: S,H->E,reply Description: Used by the host to request the current date and time from the equipment. Structure: Header-only. S2,F18 Date and Time Data (DTD) Usage: S,H<-E Description: Actual time data, equipment response to S2,F17. Structure: <A[12]>. * TIME Notes: A zero length item means no time exists. S2,F23 Trace Initialize Send (TIS) Usage: S,H->E,reply Description: Method for sampling selected status variables as a function of time. Structure: <L[5] <U2[1]> *TRID <A[6]> *DSPER <U4[1]> *TOTSMP <U4[1]> *REPGSZ <L[N]> <U2[1]> *SVID1 . . . <U2[1]> *SVIDN > >. Notes: Only 4 active traces can be supported. New trace can only be added when active trace is terminated (TOTSMP=0) S2,F24 Trace Initialize Acknowledge (TIA) Usage: S,H<-E Description: Acknowledge or error. Page - 28 - of 321 Sep 18, 2020 Rev 4.1 Kulicke & Soffa™ SECS/GEM Interface for K&S Ball Bonders Bonder software version x-xx-x-472-series Structure: <B[1]> *TIAACK S2,F29 Equipment Constant Namelist (ECNR) Usage: S,H->E,reply Description: This function allows the host to retrieve basic information about what equipment constants are available in the equipment. Structure: <L[N] <U2[1]> * ECID1 . . . <U2[1]> * ECIDN >. Notes: A zero-length list means send information for all ECIDs. S2,F30 Equipment Constant Namelist (ECN) Usage: S,H<-E Description: Data response to S2,F29 message. Structure: <L[N] (number of equipment constants) <L1[6] <U2[1]> * ECID1 <A[MAX 40]> * ECNAME1 <V> * ECMIN1 <V> * ECMAX1 <V> * ECDEF1 <A[MAX N]> * UNITS1 > . . . <LN[6] <U2[1]> * ECIDN <A[MAX 40]> * ECNAMEN <V> * ECMINN <V> * ECMAXN <V> * ECDEFN <A[MAX N]> * UNITSN > >. S2,F31 Date and Time Set Request (DTS) Usage: S,H->E,reply Description: The host requests the equipment to set its internal clock to the indicated TIME. Structure: <A[12]>. * TIME S2,F32 Date and Time Set Acknowledge (DTA) Usage: S,H<-E Description: Acknowledge the receipt of the date and time. Structure: <B[1]>. * TIACK S2,F33 Define Report (DR) Usage: S,H->E,reply Description: Used by the host to associate equipment variables with discrete reports to be provided with collection events. Association is performed by grouping specific equipment-defined VIDs with hostdefined RPTIDs. In SECS-I environments, if this message is multi-block, then it must be preceded by a successful S2,F39/S2,F40 Inquire/Grant transaction. Page - 29 - of 321 Sep 18, 2020 Rev 4.1 Kulicke & Soffa™ SECS/GEM Interface for K&S Ball Bonders Bonder software version x-xx-x-472-series Structure: <L[2] <U2[1]> <L[N] * DATAID <L1[2] <U2[1]> <L[M] * RPTID1 <U2[1]> * SVID1 . . . <U2[1]> * SVIDM > > . . . <LN[2] <U2[1]> <L[M] * RPTIDN <U2[1]> * SVID1 . . . <U2[1]> * SVIDM > > > >. S2,F34 Define Report Acknowledge (DRA) Usage: S,H<-E Description: Acknowledge or error. If an error condition is detected the entire message is rejected (i.e. partial changes are not allowed). Structure: <B[1]>. * DRACK Page - 30 - of 321 Sep 18, 2020 Rev 4.1 Kulicke & Soffa™ SECS/GEM Interface for K&S Ball Bonders Bonder software version x-xx-x-472-series S2,F35 Link Event Report (LER) Usage: S,H->E,reply Description: Used by the host to associate reports with specific collection events on the equipment. Association is performed by grouping host-defined RPTIDs with equipment-defined CEIDs. A report must be defined before it is linked to an event (see S2,F33). In SECS-I environments, if this message is multi-block, then it must be preceded by a successful S2,F39/S2,F40 Inquire/Grant transaction. Structure: <L[2] <U2[1]> * DATAID <L[N] <L1[2] <U2[1]> * CEID1 <L[M] <U2[1]> * RPTID1 . . . <U2[1]> * RPTIDM > > . . . <LN[2] <U2[1]> * CEIDN <L[M] <U2[1]> * RPTID1 . . . <U2[1]> * RPTIDM > > > >. Notes: If N=0, then all report links will be deleted; report definitions will not be changed. If M=0, then all report links to the specified CEID will be deleted; otherwise, all report links to the CEID will be replaced. There is no explicit limit placed on the number of reports linked to an event. The equipment allows multiple instances of a report to be linked to an event. Event reporting links will remain unchanged should the host modify a report via a subsequent S2,F33 message. The format of the resulting event report messages (S6,F11), however, may change. S2,F36 Link Event Report Acknowledge (LERA) Usage: S,H<-E Description: Acknowledge or error. If an error condition is detected the entire message is rejected (i.e. partial changes are not allowed). Structure: <B[1]>. * LRACK Page - 31 - of 321 Sep 18, 2020 Rev 4.1 Kulicke & Soffa™ SECS/GEM Interface for K&S Ball Bonders Bonder software version x-xx-x-472-series S2,F37 Enable/Disable Event Report (EDER) Usage: S,H->E,reply Description: Used by the host to enable or disable specific event reports on the equipment. Structure: <L[2] <BL[1]> * CEED <L[N] <U2[1]> * CEID1 . . . <U2[1]> * CEIDN > >. S2,F38 Enable/Disable Event Report Acknowledge (EERA) Usage: S,H<-E Description: Acknowledge or error. If an error condition is detected the entire message is rejected (i.e. partial changes are not allowed). Structure: <B[1]>. * ERACK S2,F39 Multi-Block Inquire (MBI) Usage: S,H->E,reply Description: Used by the host in SECS-I environments to request permission to send a multi block Stream 2 message to the equipment. Structure: <L[2] <U2[1]> * DATAID <U4[1]> * DATALENGTH >. S2,F40 Multi-Block Grant (MBG) Usage: S,H<-E Description: Grant permission to send multi-block message. Structure: <B[1]>. * GRANT S2,F41 Host Command Send (HCS) Usage: S,H->E,reply Description: The host requests the equipment perform a specified remote command. Structure: <L[2] <A[MAX 20]> * RCMD <L[MAX 1] <L[2] <A[MAX N]> * CPNAME <V> * CPVAL > > >. Page - 32 - of 321 Sep 18, 2020 Rev 4.1 Kulicke & Soffa™ SECS/GEM Interface for K&S Ball Bonders Bonder software version x-xx-x-472-series S2,F42 Host Command Acknowledge (HCA) Usage: S,H<-E Description: Host command acknowledge or error. Structure: <L[2] <B[1]> * HCACK <L[1] ** <L[2] <A[MAX N ]> * CPNAME <V> * CPACK > > >. Notes: ** If HCACK= 0 or 4 then <L[0]>. S2,F43 Reset Spooling Streams and Functions (RSSF) Usage: S,H->E,reply Description: This message allows the host to select specific streams and functions to be spooled whenever spooling is active. Structure: <L[M] <L1[2] <U1[1]> * STRID <L[N] <U1[1]> * FCNID1 . . . <U1[1]> * FCNIDN > > . . . <LM[2] <U1[1]> <L[N] * STRID <U1[1]> . . . <U1[1]> * FCNID1 * FCNIDN > Notes: > >. A zero-length list, M=0 turns off spooling for all streams and functions. A zero-length list, N=0, turns off spooling for all functions for the stream. Spooling for Stream 1 is not allowed. The equipment must allow the host to spool all primary messages for a stream (except Stream 1). A defined list of functions for a stream will replace any previously selected functions. Page - 33 - of 321 Sep 18, 2020 Rev 4.1 Kulicke & Soffa™ SECS/GEM Interface for K&S Ball Bonders Bonder software version x-xx-x-472-series S2,F44 Reset Spooling Acknowledge (RSA) Usage: S,H<-E Description: Response to S2,F43 message; acknowledge or error. Structure: <L[2] <B[1]>. * RSPACK <L[M] <L1[3] <U2[1]> * STRID1 <B[1]>. * STRACK1 <L[N] <U1[1]> * FCNID1 . . . <U1[1]> * FCNIDN > > . . . <LM[3] <U2[1]> * STRIDM <B[1]> * STRACKM <L[N] <U1[1]> * FCNID1 . . . <U1[1]> * FCNIDN > > > >. Notes: If RSPACK = 0, then a zero-length list, M=0 is given, indicating no streams or functions in error. A zero-length list, N=0, indicates no functions in error for specified. S2,F45 Define Variable Limit Attributes (DVLA) Usage: M,H->E,reply Description: This message allows the host to define multiple limits to be applied to selected status variables (SV’s). Structure: <L[2] <U2[1]> * DATAID <L[M] (M = # VIDs) <L1[2] <U2[1]> * VID1 <L[N] (N = #Limits for this VID) <L1[2] <B[1]> * LIMITID1 <L[P] (p={0,2}) <V> *UPPERDB <V> *LOWERDB > > . Page - 34 - of 321 Sep 18, 2020 Rev 4.1 Kulicke & Soffa™ SECS/GEM Interface for K&S Ball Bonders Bonder software version x-xx-x-472-series . . <LN[2] <B[1]> * LIMITIDN <L[P] (p={0,2}) <V> *UPPERDB <V> *LOWERDB > > > > . . <LM[2] <U2[1]> <L[N] * VIDM (N = #Limits for this VID) <L1[2] <B[1]> * LIMITID1 <L[P] (p={0,2}) <V> *UPPERDB <V> *LOWERDB > > . . . <LN[2] <B[1]> * LIMITIDN <L[P] (p={0,2}) <V> *UPPERDB <V> *LOWERDB > > > > > Notes: >. A zero-length list, M=0, sets all limit values for all monitored VIDs to "undefined. A zero-length list, N=0, sets all limits values for that VID to "undefined. A zero-length list, P=0, sets that limit to "undefined." S2,F46 Variable Limit Attribute Acknowledge (VLAA) Usage: M,H<-E,reply Description: Acknowledge definition of variable limit attributes or report error. If DVLA is not accepted due to one or more invalid parameters (e.g., LIMITACK=3), then a list of invalid parameters is returned containing the variable limit attribute and reason for rejection. If an error condition is detected, the entire message is rejected, i.e., partial changes are not allowed. Page - 35 - of 321 Sep 18, 2020 Rev 4.1 Kulicke & Soffa™ SECS/GEM Interface for K&S Ball Bonders Bonder software version x-xx-x-472-series Structure: <L[2] <B[1]> <L[M] * VLAACK <L1[3] <U2[1]> <B[1]> <L[N] * VID1 * LVACK1 (N={0,2}) <B[1]> * LIMITID1 <B[1]> * LIMITACK1 > > . . . <LM[3] <U2[1]> <B[1]> <L[N] * VIDM * LVACKM (N={0,2}) <B[1]> * LIMITIDM <B[1]> * LIMITACKM > > Notes: > >. A zero-length list, M=0, indicates no invalid variable limit attributes. A zero-length list, N=0, indicates no invalid limit values for that VID. S2,F47 Variable Limit Attribute Request (VLAR) Usage: S,H->E,reply Description: This message allows the host to query the equipment for current variable limit attribute definitions. Structure: <L[N] <U2[1]> * VID1 . . . <U2[1]> * VIDN >. Notes: A zero-length list, N=0, requests a list of all VID values that can have variable limit attributes. S2,F48 Variable Limit Attributes Send (VLAS) Usage: M,H<-E,reply Description: Equipment sends values of requested variable limit attribute definitions in the order requested. Structure: <L[M] (M = # VIDs) <L1[2] <U2[1]> * VID1 <L[P] (P={0,4}) <A[R] * UNITS1 <V> * LIMITMIN1 <V> * LIMITMAX1 <L[N] <L1[3] <B[1]> * LIMITID1 <V> * UPPERDB1 <V> * LOWERDB1 > . Page - 36 - of 321 Sep 18, 2020 Rev 4.1 Kulicke & Soffa™ SECS/GEM Interface for K&S Ball Bonders Bonder software version x-xx-x-472-series . . <LN[3] <B[1]> * LIMITIDN <V> * UPPERDBN <V> * LOWERDBN > > > > . . . <LM[2] <U2[1]> <L[P] * VIDM (P={0,4}) * UNITSM * LIMITMINM * LIMITMAXM <A[R] <V> <V> <L[N] <L1[3] <B[1]> * LIMITID1 <V> * UPPERDB1 <V> * LOWERDB1 > . . . <LN[3] <B[1]> * LIMITIDN <V> * UPPERDBN <V> * LOWERDBN > > > > Notes: >. A zero-length list, P=0, indicates that limits are not supported for the VID. A zero-length list, N=0, indicates that no limits are currently defined for the VID. S5,F3 Enable/Disable Alarm Send (EAS) Usage: S,H->E,reply Description: Allows the host to selectively enable or disable individual alarms the equipment. Structure: <L[2] <B[1]> * ALED <U2[1]> * ALID >. Notes: A zero length ALID means all alarms. S5,F4 Enable/Disable Alarm Acknowledge (EAA) Usage: S,H<-E Description: Acknowledge or error. Structure: <B[1]>. * ACKC5 S5,F5 List Alarms Request (LAR) Usage: S,H->E,reply Description: Requests the equipment to provide current alarm information to the host. Page - 37 - of 321 Sep 18, 2020 Rev 4.1 Kulicke & Soffa™ SECS/GEM Interface for K&S Ball Bonders Bonder software version x-xx-x-472-series Structure: <U2[N]>. * ALID1,.., ALIDN S5,F6 List Alarms Data (LAD) Usage: S,H<-E Description: Equipment response to S5,F5. The equipment sends current alarm data to the host. Structure: <L[N] <L1[3] <B[1]> * ALCD1 <U2[1]> * ALID1 <A[MAX 40]> * ALTX1 > . . . <LN[3] <B[1]> * ALCDN <U2[1]> * ALIDN <A[MAX 40]> * ALTXN > >. Notes: If a specified ALID does not exist, then zero-length ALCD and ALTX fields will be returned. S6,F15 Event Report Request (ERR) Usage: S,H->E,reply Description: Used by the host to request an event report for a given CEID. Structure: <U2[1]>. * CEID Page - 38 - of 321 Sep 18, 2020 Rev 4.1 Kulicke & Soffa™ SECS/GEM Interface for K&S Ball Bonders Bonder software version x-xx-x-472-series S6,F16 Event Report Data (ERD) Usage: S,H<-E Description: Equipment reply to host-originated S6,F15. S6,F16 is identical in format to S6,F11. Structure: <L[3] <U2[1]> * DATAID <U2[1]> * CEID <L[N] <L1[2] <U2[1]> * RPTID1 <L[M] <V> * V1 . . . <V> * VM > > . . . <LN[2] <U2[1]> * RPTIDN <L[M] <V> * V1 . . . <V> * VM > > > >. S6,F19 Individual Report Request (IRR) Usage: S,H->E,reply Description: Used by the host to request a report via RPTID. Structure: <U2[1]> * RPTID S6,F20 Individual Report Data (IRD) Usage: S,H<-E Description: Equipment reply to host-originated S6,F19. Structure: <L[N] <V> * V1 . . . <V> * VN >. Notes: A zero-length list, N=0, means that there are no variables linked to the given RPTID or that the given RPTID does not exist. S6,F23 Request Spooled Data (RSD) Usage: S,H->E,reply Description: Host requests transmission or deletion of the messages currently spooled by the equipment. Structure: <B[1]>. * RSDC S6,F24 Request Spooled Data Acknowledgment Send (RSDAS) Page - 39 - of 321 Sep 18, 2020 Rev 4.1 Kulicke & Soffa™ SECS/GEM Interface for K&S Ball Bonders Bonder software version x-xx-x-472-series Usage: Description: Structure: S,H<-E Equipment acknowledges the receipt of the S6,F23 message. <B[1]>. * RSDA S7,F1 Process Program Load Inquire (PPI) Usage: S,H->E,reply Description: This message is used by the host to inquire whether or not the equipment will accept the download of a multi-block process program. Structure: <L[2] <A[MAX 80]> * PPID <U4[1]> * LENGTH >. S7,F2 Process Program Load Grant (PPG) Usage: S,H<-E Description: Equipment reply to host-originated S7,F1. Used to acknowledge or reject host request to download multi-block process program. Structure: <B[1]>. * PPGNT S7,F3 Process Program Send (PPS) Usage: M,H->E,reply Description: Used by the host to send an existing process program to the equipment. Structure: <L[2] <A[MAX 80]> * PPID <B[MAX N]> * PPBODY >. Notes: The equipment must be in HIT mode in order to use this capability. S7,F4 Process Program Acknowledge (PPA) Usage: S,H<-E Description: Equipment reply to host-originated S7,F3. Used to acknowledge or reject process program downloaded from the host. Structure: <B[1]>. * ACKC7 S7,F5 Process Program Request (PPR) Usage: S,H->E,reply Description: Used by the host to request an existing process program from the equipment. Structure: <A[MAX 80]>. * PPID S7,F6 Process Program Data (PPD) Usage: M,H<-E Description: Equipment reply to host-originated S7,F6. Used to upload process programs from the equipment to the host. Structure: <L[2] <A[MAX 80]> * PPID <B[MAX N]> * PPBODY >. NOTES: If doing an unformatted upload, L[0] returned on the first S7,F6. S7,F17 Delete Process Program Send (DPS) Usage: S,H->E,reply Description: Host requests the equipment to delete process programs from equipment storage. Page - 40 - of 321 Sep 18, 2020 Rev 4.1 Kulicke & Soffa™ SECS/GEM Interface for K&S Ball Bonders Bonder software version x-xx-x-472-series Structure: <L[N] <A[MAX 80]> . . . <A[MAX 80]> Notes: * PPID1 * PPIDN >. If N=0, then delete all. S7,F18 Delete Process Program Acknowledge (DPA) Usage: S,H<-E Description: Acknowledge receipt of S7,F17 message. Structure: <B[1]>. * ACKC7 S7,F19 Current EPPD Request (RER) Usage: S,H->E,reply Description: Used by the host to request the equipment process program directory (EPPD). The EPPD is a list of all PPIDs currently available for use at the equipment. The equipment must be in HIT mode, otherwise S7,F20 <L[0]>. is returned. Structure: Header-only. S7,F20 Current EPPD Data (RED) Usage: M,H<-E Description: Used by the equipment to transfer its current EPPD to the host. Structure: <L[N] <A[MAX 80]> * PPID1 . . . <A[MAX 80]> * PPIDN >. S10,F3 Terminal Display, Single (VTN) Usage: S,H->E,reply Description: The host requests the equipment to display a single line of text on its terminal display. Structure: <L[2] <B[1]> * TID <A[MAX 80]> * TEXT >. S10,F4 Terminal Display, Single Acknowledge (VTA) Usage: S,H<-E Description: Equipment response to S10,F3. Structure: <B[1]>. * ACKC10 S10,F5 Terminal Display, Multi-Block(VTM) Usage: S,H->E,reply Description: The host requests the equipment to display multiple lines of text on its terminal display. Page - 41 - of 321 Sep 18, 2020 Rev 4.1 Kulicke & Soffa™ SECS/GEM Interface for K&S Ball Bonders Bonder software version x-xx-x-472-series Structure: <L[2] <B[1]> <L[N] * TID <A[MAX 80]> . . . <A[MAX 80]> * TEXT * TEXT > >. S10,F6 Terminal Display, Multi-Block Acknowledge (VMA) Usage: S,H<-E Description: Equipment response to S10,F5. Structure: <B[1]>. * ACKC10 S13,F1 Send Data Set Send (DSSS) Usage: S,H<->E,reply Description: Sent by the sending system to request that the other system read a dataset. Structure: L,1 1.<DSNAME> S13,F2 Send Data Set Acknowledge (DSSA) Usage: S,H<->E Description: Sent by the receiving system in response to Send Data Set Send. Structure: L,2 1. <DSNAME> 2. <ACKC13> Exceptions: The possible ACKC13 codes for this message are: 0=O.K. 1=ERROR:Try later. 2=ERROR:Unknown Data Set Name. Page - 42 - of 321 Sep 18, 2020 Rev 4.1 Kulicke & Soffa™ SECS/GEM Interface for K&S Ball Bonders Bonder software version x-xx-x-472-series 3.3 Equipment-Originated Transactions This section details the primary SECS-II messages understood by the host and the associated secondary replies (where applicable). Sx,F0 Abort Transaction (SxF0) Usage: S,H<-E Description: Used with all streams in lieu of an expected message to abort a transaction. Structure: Header-only. S1,F1 Are You There Request (R) Usage: S,H<-E,reply Description: Used to test host on-line. A function 0 response to S1,F1 indicates SECS communication is inoperative (equivalent to a T3 (reply) timeout at the equipment). The equipment may issue this message at any time to test the SECS link. Structure: Header-only. S1,F2 On Line Data (D) Usage: S,H->E Description: Host reply to equipment-originated S1,F1. Structure: <L[0]>. S1,F13 Establish Communications Request (CR) Usage: S,H<-E,reply Description: Used by the equipment to attempt to initialize communications with the host. Structure: <L[2] <A[MAX 6]> * MDLN <A[MAX 6]> * SOFTREV >. S1,F14 Establish Communications Request Acknowledge (CRA) Usage: S,H->E Description: Host- reply to equipment originated S1,F13. Structure: <L[2] <B[1]> * COMMACK <L[0]> >. S5,F1 Alarm Report Send (ARS) Usage: S,H<-E,[reply] Description: Report change in or presence of an alarm condition. Structure: <L[3] <B[1]> * ALCD <U2[1]> * ALID <A[MAX 40]> * ALTX >. Notes: A zero-length item means no time exists. S5,F2 Alarm Report Acknowledge (ARA) Usage: Description: S,H<-E Host acknowledge alarm send. <B[1]>. * ACKC5 Page - 43 - of 321 Sep 18, 2020 Rev 4.1 Kulicke & Soffa™ SECS/GEM Interface for K&S Ball Bonders Bonder software version x-xx-x-472-series S6,F1 Trace Data Send Usage: M,H<-E,[reply] Description: Used by the equipment to send samples to the host according to the trace setup done by S2,F33. Structure: <L[4] <U2[1]> *TRID <U,I> *SMPLN <A[12]> *STIME <L[N] <U2[1]> *SVID . . . <U2[1]> *SVID > > Notes: A zero-length STIME means no value is given and that the time is to be derived from SMPLN. S6,F2 Trace Data Acknowledge Usage: Acknowledge or error. Structure:<B[1]> *ACKC6 S6,F5 Multi-block Data Send Inquire (MBI) Usage: S,H<-E,reply Description: If the discrete data report S6,F3/F9/F11/F13 is more than one block, then inquire if host will accept the report. Structure: <L[2] <U2[1]> * DATAID <U4[1]> * DATALENGTH >. S6,F6 Multi-block Grant (MBG) Usage: S,H->E Description: Acknowledge or error. Structure: <B[1]>. * GRANT6 S6,F11 Event Report Send (ERS) Usage: M,H<-E,[reply] Description: Used by the equipment to notify the host of an event. Page - 44 - of 321 Sep 18, 2020 Rev 4.1 Kulicke & Soffa™ SECS/GEM Interface for K&S Ball Bonders Bonder software version x-xx-x-472-series Structure: <L[3] <U2[1]> <U2[1]> <L[N] * DATAID * CEID <L1[2] <U2[1]> <L[M] * RPTID1 <V> . . . <V> * V1 * VM > > . . <LN[2] <U2[1]> <L[M] * RPTIDN <V> . . . <V> * V1 * VM > > > >. S6,F12 Event Report Acknowledge (ERA) Usage: S,H->E Description: Acknowledges an event report from the equipment (optional). Structure: <B[1]>. * ACKC6 Notes: The equipment ignores the value of ACKC6. S7,F1 Process Program Load Inquire (PPI) Usage: S,H<-E,reply Description: This message is used by the equipment to inquire whether or not the host will accept upload of a multi-block process program. Structure: <L[2] <A[MAX 80]> * PPID <U4[1]> * LENGTH >. S7,F2 Process Program Load Grant (PPG) Usage: S,H->E Description: Host reply to equipment-originated S7,F1. Used to acknowledge or reject equipment request to upload multi-block process program. Structure: <B[1]>. * PPGNT S7,F3 Process Program Send (PPS) Usage: M,H<-E,reply Description: Used by the equipment to send an existing process program to the host. Structure: <L[2] <A[MAX 80]> * PPID <B[MAX N]> * PPBODY >. S7,F4 Process Program Acknowledge (PPA) Page - 45 - of 321 Sep 18, 2020 Rev 4.1 Kulicke & Soffa™ SECS/GEM Interface for K&S Ball Bonders Bonder software version x-xx-x-472-series Usage: Description: Structure: S,H->E Host reply to equipment originated S7,F3. Used to acknowledge or reject process program uploaded from the equipment. <B[1]>. * ACKC7 S7,F5 Process Program Request (PPR) Usage: S,H<-E,reply Description: Used by the equipment to request an existing process program from the host. Structure: <A[MAX 80]>. * PPID S7,F6 Process Program Data (PPD) Usage: M,H->E Description: Host reply to equipment-originated S7,F5. Used to download process programs from the host to the equipment. Structure: <L[2] <A[MAX 80]> * PPID <B[MAX N]> * PPBODY >. Notes: A zero length list means request denied. S9,F1 Unrecognized Device ID (UDN) Usage: S,H<-E Description: Sent by the equipment when a message is received containing an unrecognized device ID. Structure: <B[10]>. * MHEAD Notes: S9,F2 is not used. S9,F3 Unrecognized Stream Type (USN) Usage: S,H<-E Description: Sent by the equipment when a message is received containing an unrecognized stream number. Structure: <B[10]>. * MHEAD Notes: S9,F4 is not used. Page - 46 - of 321 Sep 18, 2020 Rev 4.1 Kulicke & Soffa™ SECS/GEM Interface for K&S Ball Bonders Bonder software version x-xx-x-472-series S9,F5 Unrecognized Function Type (UFN) Usage: S,H<-E Description: Sent by the equipment when a message is received containing an unrecognized function number. Structure: <B[10]>. * MHEAD Notes: S9,F6 is not used. S9,F7 Illegal Data (IDN) Usage: S,H<-E Description: Sent by the equipment when a message is received containing an invalid data format. Structure: <B[10]>. * MHEAD Notes: S9,F8 is not used. S9,F9 Transaction Timer Timeout (TTN) Usage: S,H<-E Description: Sent by the equipment when a transaction timer times out. Structure: <B[10]>. * SHEAD Notes: S9,F10 is not used. S9,F11 Data Too Long (DLN) Usage: S,H<-E Description: Sent by the equipment when the equipment receives more data than it can handle. Structure: <B[10]>. * MHEAD Notes: S9,F12 is not used. S10, F1 Terminal Request (TRN) Usage: S,H<-E,reply Description: A terminal text message to the host. Structure: <L[2] <B[1]> <A[MAX 80]> * TID * TEXT >. S10, F2 Terminal Request Acknowledge (TRA) Usage: S,H->E Description: Acknowledge or error. Structure: <B[1]>. * ACKC10 S13,F3 Open Data Set Request (DSOR) Usage: S,H<-E Description: Sent by the receiving system to open a data set for reading. Structure: <L[3] <U2[1]> * HANDLE <A[40]> *DSNAME <U4[1]> *CKPNT >. S13,F4 Open Data Set Data (DSOD) Usage: S,H->E Description: Sent by the sending system in response to Open Data Set Request. Structure: <L[5] <U2[1]> *HANDLE <A[40]> * DSNAME <Bi[1]> *ACKC13 <U2[1]> *RTYPE Page - 47 - of 321 Sep 18, 2020 Rev 4.1 Kulicke & Soffa™ SECS/GEM Interface for K&S Ball Bonders Bonder software version x-xx-x-472-series <U4[1]> *RECLEN >. S13,F5 Read Data Set Request (DSRR) Usage: S,H<-E Description: Sent by the receiving system to read data from an open data set. Structure: <L[2] <U2[1]> * HANDLE <U4[1]> *READLN >. S13,F6 Read Data Set Data (DSRD) Usage: M,H->E Description: Sent by the sending system in response to Read Data Set Request. Structure: <L[4] <U2[1]> *HANDLE <Bi[ 1 ]> *ACKC13 <U4[1]> *CKPNT <L[1] <B[RECLEN]> *FILDAT > >. S13,F7 Close Data Set Send (DSCS) Usage: S,H<-E > Description: Sent by the receiving system to close an open data set. Structure: <L[1] <U2[1] *HANDLE >. S13,F8 Close Data Set Acknowledge (DSCA) Usage: S,H->E Description: Sent by the sending system in response to Close Data Set Send (DSCS). Structure: <L[2] <U2[1]> *HANDLE <Bi[1]> *ACKC13 >. S14,F1 GetAttr Request(GAR) Usage: Description: S, H<->E This message is used to request a set of specified attributes for one or more objects. It consists of an “object specifier” for the owner of the target objects (the objects of interest), the target object type, a list of identifiers of the target objects, a filter (a list of qualifying relationships) that limits the target objects of interest to those that meet all of the qualifications in and the specific attributes whose values are requested. The object specifier provides a specification of the owner of the target objects. It contains a sequence of hierarchical object relationships. Each element of the object specifier indentifies a specific object instance that is the superior of the following object instance in the sequence. The last object type designates the type of the target object, and the list of the object indentifiers indicates the specific instance of tha t type that are of interest. The target type may be omitted only if object identifiers are unique across all object types and the list of the identifiers is not empty. Page - 48 - of 321 Sep 18, 2020 Rev 4.1 Kulicke & Soffa™ SECS/GEM Interface for K&S Ball Bonders Bonder software version x-xx-x-472-series The object filter is an optional list of qualifications, each of which provides a condition to be applied to the object instances of interest. Each qualification objects of interest are those that meet all of the specified qualifications. The attribute relationship quantifier is a logical binary relationship ATTRRELNi that the specified qualifying value ATTRDATAi has to be the corresponding attribute of each instance of the desired object type(s). The objects that are to be qualified with this filter have an attribute value Vi such that the statement “ATTRDATAi ATTRRELNi Vi” is TRUE. IF ATTRRELNi is omitted, the relationship of equality is intended. For ASCII attribute values ATTRDATAi, the characters for question mark “?” and asterisk “*” are used as “wild characters” to provide filtering for certain object types. The character “?” may be used in any attribute or key attribute value with an ASCII format to represent “any single character” and may be repeated. The asterisk character “*” may be similarly used to represent a variable-length string, including a null string. The string “*x” represents a string of any length that ends in “x”, the string “x*” represents any string that begins with “x”, and the string “*” represents any string of any none-zero length. The comparison for text characters is case insensitive. Equipment is not required to support wild characters in particular, or attribute filters in general. Structure: <L[5] <OBJSPEC> <OBJTYPE> <L[i] <OBJID1> . . <OBJIDi> > < L[q] <L1[3] <ATTRID1> <ATTRDATA1> <ATTRRELEN1> > . . <Lq[3] <ATTRID1> <ATTRDATA1> <ATTRRELEN1> > > <L[a] < ATTRID1> . . < ATTRIDa> > >. Notes: If OBJSPEC is a zero-length item, no object specifier is provided. If i = 0, only the filter is to be applied. If q = 0, no filter is specified. If both I and q = 0, information for all instances of the objects are requested. If a = 0, all attributes are requested. S14,F2 GetAttr Data (GAD) Usage: M, H<->E Description: This message is used to transfer the set of requested attributes for the specified objects. The order of attributes is retained from the primary message. Structure: <L[2] <L[n] <L[2] Page - 49 - of 321 Sep 18, 2020 Rev 4.1 Kulicke & Soffa™ SECS/GEM Interface for K&S Ball Bonders Bonder software version x-xx-x-472-series <OBJID1> <L[2] <ATTRID1> <ATTRDATA1> > . . <L[2] <ATTRIDa> <ATTRDATAa> > > <L[2] <OBJIDn> <L[2] <ATTRID1> <ATTRDATA1> > . . <L[2] <ATTRIDb> <ATTRDATAb> > > > <L[2] <OBJACK> <L[p] <L[2] <ERRCODE1> <ERRTEXT1> > . . <L[2] <ERRCODEp> <ERRTEXTp> > > > >. Notes: If OBJSPEC is a zero-length item, no object specifier is provided. If n = 0, no objects matched the specified filter. If p = 0, no errors were detected. 4. State Models, Capabilities, and Scenarios The following sections describe the equipment in terms of GEM state models, GEM capabilities, and commonly used equipment operating scenarios. 4.1 Communications Communications State Model The equipment will support the GEM Communications State Model as described by the SEMI E30 standard. Page - 50 - of 321 Sep 18, 2020 Rev 4.1 Kulicke & Soffa™ SECS/GEM Interface for K&S Ball Bonders Bonder software version x-xx-x-472-series 1 COMMUNICATIONS DISABLED C ENABLED 2 3 4 NOT COMMUNICATING 10 HOST-INITIATED CONNECT EQUIPMENT-INITIATED CONNECT WAIT CR FROM HOST WAIT DELAY 11 12 8 WAIT TX COMPLETE 13 5 7 6 WAIT CRA 14 9 COMMUNICATING Figure 6 - GEM Communications State Model The Communications State Model may be enabled or disabled (refer to the Communications State Model equipment constant). If the Communications State Model is enabled, then communications will be established when an S1,F13 Establish Communications Request (CR)/S1,F14 Establish Communications Request Acknowledge (CRA) transaction completes successfully. Otherwise, if the Communications State Model is disabled, the S1,F1 Are You There Request (R)/S1,F2 On Line Data (D) transaction may be used to determine the communications state. When the Communications State Model is disabled, SECS communications will function in a “connectionless” mode; the COMMUNICATING sub-state of the model will be assumed. Page - 51 - of 321 Sep 18, 2020 Rev 4.1 Kulicke & Soffa™ SECS/GEM Interface for K&S Ball Bonders Bonder software version x-xx-x-472-series Communications State Transitions # CURRENT STATE TRIGGER EVENT NEW STATE Action COMMENT 1 (Entry to COMMUNICATIONS) System initialization System Default None 2 DISABLED ENABLED None 3 ENABLED DISABLED None SECS-II communications are prohibited 4 (Entry to ENABLED) Operator switches from DISABLED to ENABLED Operator switches from ENABLED to DISABLED Any entry to ENABLED state The system default may be set to DISABLED or ENABLED SECS-II communications are enabled NOT COMMUNICATING None 5 (Entry to EQUIPMENTINITIATED CONNECT) (Any entry to NOT COMMUNI-CATING) WAIT CRA 6 WAIT CRA WAIT DELAY 7 WAIT DELAY 8 WAIT DELAY Connection transaction failure Comm-Delay timer expired Received a message other than S1,F13. Initialize communication. Set Comm-Delay timer "expired." Send S1,F13 Initialize CommDelay timer Send S1,F13 May enter from system initialization to ENABLED or through operator switch to ENABLED Begin the attempt to establish communications 9 WAIT CRA COMMUNICATING 10 WAIT CR FROM HOST None Wait for S1,F13 from Host Received S1,F13 12 (Entry to HOSTINITIATED CONNECT) WAIT CR FROM HOST WAIT TX COMPLETE Received expected S1,F14 with COMMACK = 0 (Any entry to NOT COMMUNI-CATING) Send S1,F14 with COMMACK = 0 None Host seeks to establish communications Wait for S1,F13 from Host 13 WAIT TX COMPLETE None 14 COMMUNICATING WAIT TX COMPLETE WAIT CR FROM HOST COMMUNICATING NOT COMMUNICATING Communications are established Dequeued messages may be placed in spool buffer as appropriate 11 S1,F14 transmission failed S1,F14 transmission completed successfully Communication failure WAIT CRA WAIT CRA Discard message. No reply. Set CommDelay timer "expired". Send S1,F13 None Dequeue all messages queued to send Wait for timer to expire Wait for S1,F14. May receive S1,F13 from Host Indicates opportunity to establish communications Communications established Figure 7 – Communications State Transitions In the ENABLED/NOT COMMUNICATING communications state, the equipment will only accept S1,F13 Establish Communications Request (CR) and stream 9 messages. When the equipment receives an S1,F13 Establish Communications Request (CR) message it responds with an S1,F14 Establish Communications Request Acknowledge (CRA) message. If the equipment is ready to establish communications, then COMMACK is set to 0. Otherwise, COMMACK is set to 1. When the S1,F14 Establish Communications Request Acknowledge (CRA) Communications message, with COMMACK = 0, is sent successfully, the equipment changes its communications state from ENABLED/NOT COMMUNICATING to ENABLED/COMMUNICATING and its control state is set to its default state. If the equipment receives an the S1,F13 Establish Communications Request (CR) message from the host and the communications state is already set to ENABLED/COMMUNICATING, then the equipment will respond with an S1,F14 Establish Communications Request Acknowledge (CRA) reply. If the S1,F13 Establish Communications Request (CR)/S1,F14 Establish Communications Request Acknowledge (CRA) transaction is not being used to establish communications (the Communications State Model is disabled), then the communications state will always be ‘COMMUNICATING’. A status variable (CommEnabled) is used to determine whether or not the equipment has disabled communications. When the equipment receives an S1,F1 Are You There Request ® message and communications are enabled, it replies with an S1,F2 On Line Data (D) message. If communications are disabled the equipment will not respond to any messages received from the host. Page - 52 - of 321 Sep 18, 2020 Rev 4.1 Kulicke & Soffa™ SECS/GEM Interface for K&S Ball Bonders Bonder software version x-xx-x-472-series An equipment constant(DisableCommunicationsStateModel) will determine whether the S1,F13 Establish Communications Request (CR)/S1,F14 Establish Communications Request Acknowledge (CRA) transaction or the S1,F1 Are You There Request ®/S1,F2 On Line Data (D) transaction establishes communications. Host Attempts to Establish Communications This scenario is used when the communications state model has been enabled. COMMENT HOST EQUIPMENT COMMENT Communications state is ENABLED (any substate). Establish communications S1,F13→ request. S1,F14 Reply COMMACK = 0 and communications state = COMMUNICATING. Figure 8 – Scenario: Host Attempts to Establish Communications Host-Initiated Are You There COMMENT Are You There request. HOST EQUIPMENT COMMENT S1,F1→ S1,F2 On-Line Data response. Figure 9 – Scenario: Host-Initiated Are You There Equipment-Initiated Are You There COMMENT HOST EQUIPMENT COMMENT S1,F1 Are You There request. On-Line Data response. S1,F2→ Figure 10 – Scenario: Equipment-Initiated Are You There Page - 53 - of 321 Sep 18, 2020 Rev 4.1 Kulicke & Soffa™ SECS/GEM Interface for K&S Ball Bonders Bonder software version x-xx-x-472-series 4.2 Control Control State Model The equipment will support the GEM Control State Model as described by the SEMI E30 standard. CONTROL 1 C OFF-LINE 2 EQUIPMENT OFF-LINE 12 3 4 C C ATTEMPT ON-LINE HOST OFF-LINE 6 7 11 10 5 C 8 LOCAL REMOTE 9 ON-LINE Figure 11 - GEM Control State Model Page - 54 - of 321 Sep 18, 2020 Rev 4.1 Kulicke & Soffa™ SECS/GEM Interface for K&S Ball Bonders Bonder software version x-xx-x-472-series Control State Transitions # CURRENT STATE TRIGGER EVENT NEW STATE Action COMMENT 1 (Undefined) Entry into CONTROL state (system initialization). CONTROL (Substate conditional on configuration) None Equipment may be configured to default to ON-LINE or OFFLINE*. 2 (Undefined) Entry into OFF-LINE state OFF-LINE (Substate conditional on configuration.) None Equipment may be configured to default to any substate of OFF-LINE 3 EQUIPMENTOFFLINE Operator actuates ONLINE switch ATTEMPT ON-LINE None Note that an S1,F1 is sent whenever ATTEMPT ONLINE is activated 4 ATTEMPT ON-LINE S1,F0 New state conditional on configuration None This may be due to a communication failure,** reply timeout, or receipt of S1,F0. Configuration may be set to EQUIPMENT OFF-LINE or HOST OFF-LINE 5 ATTEMPT ON-LINE Equipment receives expected S1,F2 message from the host ON-LINE None Host is notified of transition to ON-LINE at transition 7. 6 ON-LINE Operator actuates OFF-LINE switch EQUIPMENT OFF-LINE None "Equipment OFF-LINE" event occurs***. Event reply will be discarded while OFF-LINE is active 7 (Undefined) Entry to ON-LINE state ON-LINE (Substate conditional on REMOTE/ LOCAL switch setting.) None "Control State LOCAL" or "Control State REMOTE" event occurs. Event reported based on actual ON-LINE substate activated 8 LOCAL Operator sets front panel switch to REMOTE REMOTE None "Control State REMOTE" event occurs 9 REMOTE Operator sets front panel switch to LOCAL LOCAL None "Control State LOCAL" event occurs 1 0 ON-LINE Equipment accepts "Set OFF-LINE" message from host (S1,F15). HOST OFFLINE None "Equipment OFF-LINE" event occurs 1 1 HOST OFF-LINE Equipment accepts host request to go ONLINE (S1,F17). ON-LINE None Host is notified to transition to ON-LINE at transition 7 1 2 HOST OFF-LINE Operator actuates OFF-LINE switch EQUIPMENT OFF-LINE None "Equipment OFF-LINE" event occurs Figure 12 – Control State Transitions * The configuration mentioned for transitions 1 and 2 should be a single setting. This would provide the user with a choice of entering the EQUIPMENT OFF-LINE, ATTEMPT ON-LINE, HOST OFF-LINE, or ON-LINE states. ** If SECS-I is used, this means the retry limit RTY is exceeded during the attempt to send a message. *** Any host initiated transaction open at the equipment must be completed. This may happen either by sending the appropriate reply to the host prior to sending the event message or by sending an Sx,FO message following the event message (i.e., after the transaction). Host Accepts ON-LINE Page - 55 - of 321 Sep 18, 2020 Rev 4.1 Kulicke & Soffa™ SECS/GEM Interface for K&S Ball Bonders Bonder software version x-xx-x-472-series COMMENT HOST Host grants ON-LINE. EQUIPMENT COMMENT S1,F1 Equipment requests ON-LINE. S1,F2→ S6,F11 Control state LOCAL or REMOTE event. Acknowledge. S6,F12→ Figure 13 – Scenario: Operator Actuates ON-LINE Switch and Host Accepts Host Denies ON-LINE COMMENT HOST EQUIPMENT COMMENT S1,F1 Equipment requests ON-LINE. Host denies ON-LINE. S1,F0→ Figure 14 – Scenario: Operator Actuates ON-LINE Switch and Host Denies Operator Sets OFF-LINE COMMENT HOST EQUIPMENT COMMENT S6,F11 Equipment requests OFF-LINE event. Acknowledge. S6,F12→ Figure 15 – Scenario: Request or Delete Spooled Data Operator Sets REMOTE COMMENT HOST EQUIPMENT COMMENT S6,F11 Control State REMOTE Event. Acknowledge. S6,F12→ Figure 16 – Scenario: Operator Sets Switch from LOCAL to REMOTE Operator Sets LOCAL COMMENT HOST EQUIPMENT COMMENT S6,F11 Control State LOCAL event. Acknowledge. S6,F12→ Figure 17 – Scenario: Operator Sets Switch from REMOTE to LOCAL Host Sets OFF-LINE COMMENT Host requests ON-LINE. HOST EQUIPMENT COMMENT S1,F15→ S1,F0 Equipment is OFF-LINE. S1,F16 Equipment is ON-LINE, transitions to default OFF-LINE state. S6,F11 Equipment Acknowledges transition to OFF-LINE state. Acknowledge. S6,F12→ Figure 18 – Scenario: Host Sets Equipment OFF-LINE Page - 56 - of 321 Sep 18, 2020 Rev 4.1 Kulicke & Soffa™ SECS/GEM Interface for K&S Ball Bonders Bonder software version x-xx-x-472-series Host Sets ON-LINE COMMENT Host requests ON-LINE. HOST EQUIPMENT COMMENT S1,F17→ S1,F18 Equipment is not HOST OFFLINE, equipment denies report. S1,F18 Equipment is HOST OFFLINE, accepts request and goes to default ON-LINE state. S6,F11 Equipment Acknowledges transition to ON-LINE LOCAL or ON-LINE REMOTE state. Acknowledge. S6,F12→ Figure 19 – Scenario: Host Sets Equipment ON-LINE 4.3 Process Process State Model The equipment will support a GEM Process State Model as required by the SEMI E30 standard. PROCESSING NOT ACTIVE 11 12 2 6 9 3 PAUSE C WAITING 4 10 5 7 EXECUTING ASSIST 8 AUTO RUN PROCESSING ACTIVE Figure 20 - K&S Model Power Series Automatic Ball Bonder and K&S Model Gen-S Automatic Ball Bonder Page - 57 - of 321 Sep 18, 2020 Rev 4.1 Kulicke & Soffa™ SECS/GEM Interface for K&S Ball Bonders Bonder software version x-xx-x-472-series Process State Transitions # CURRENT STATE TRIGGER EVENT NEW STATE Action 1 System initialization System power-up. None 2 AUTO RUN 3 AUTO RUN 4 AUTO RUN PAUSE None 5 ASSIST PROCESSING NOT ACTIVE None 6 PAUSE Operator completes job or a fatal error occurs. Auto detects an assist condition. Operator pressed STOP button to enter Sequence Stop. 1) Operator selects Abort Auto from Assist. 2) Operator selects Standby Mode. 1) Operator selects Abort Auto from Sequence Stop. 2) Operator selects Standby Mode. PROCESSING NOT ACTIVE PROCESSING NOT ACTIVE ASSIST PROCESSING NOT ACTIVE None COMMENT None None Figure 21 – State Changes for Process Model. Process States AUTO RUN ............................... In Auto Mode and RUN button pressed PAUSE ..................................... In Auto Mode, RUN button pressed and manually entered Sequence Stop by pressing Stop button from AUTO RUN. ASSIST ..................................... In Auto Mode, RUN button pressed and an assist occurred. PROCESSING NOT ACTIVE .... ALL other machine states. Page - 58 - of 321 Sep 18, 2020 Rev 4.1 Kulicke & Soffa™ SECS/GEM Interface for K&S Ball Bonders Bonder software version x-xx-x-472-series 4.4 Data Collection Event Data Collection COMMENT Send Multi-block Grant. HOST EQUIPMENT COMMENT S6,F5 If Event Report is multi-block, then send a Multi-block Inquire Message. S6,F6→ S6,F11 Host Acknowledges the Event S6,F12→ Report. Figure 22 – Scenario: Collection Event Occurs on the Equipment Host Requests Collection Event Report COMMENT HOST Host requests a collection event S6,F15→ report. Send Event Report. EQUIPMENT S6,F16 COMMENT Equipment Sends a Collection Event Report. Figure 23 – Scenario: Host Requests Collection Event Report Collection Event Reporting Setup COMMENT HOST If Define Report is Multi-block and S2,F39→ Multi-block inquire EC is enabled, then send a Multi-block inquire. EQUIPMENT S2,F40 Send the report definitions. If Link Event/Report is Multi-Block and Multi-block Inquire EC is enabled, then send a Multi-block inquire. Link Events to Report. S2,F33→ Multi-block grant. DATAIDs, RPTIDs and VIDs received by equipment. S2,F34 Sent Report Definition acknowledge. S2,F40 Multi-Block grant. S2,F39→ S2,F35→ CEIDs and RPTIDs received by equipment. S2,F36 Enable Specific Collection Events. COMMENT S2,F37→ S2,F38 Event linkages accepted. Acknowledge = 0 Enable/Disable CEIDs. Enable events accepted. Acknowledge = 0 Figure 24 – Scenario: Collection Event Report Setup Host Requests Report COMMENT Host request data variables contained in report RPTID. HOST S6,F19→ EQUIPMENT S6,F20 Page - 59 - of 321 Sep 18, 2020 Rev 4.1 Kulicke & Soffa™ COMMENT Equipment responds with a list of variable data for the given RPTID. SECS/GEM Interface for K&S Ball Bonders Bonder software version x-xx-x-472-series Figure 25 – Scenario: Host Requests Report Equipment Status Report COMMENT Host requests report of selected status variable values. HOST S1,F3→ EQUIPMENT S1,F4 COMMENT Equipment responds with the requested status variable data. Figure 26 – Scenario: Host Requests Equipment Status Report Equipment Status Variable Namelist Report COMMENT Host requests equipment identify status variables. HOST S1,F11→ EQUIPMENT S1,F12 COMMENT Equipment responds with the requested status variable descriptions. Figure 27 – Scenario: Host Requests Equipment Status Namelist 4.5 Alarms Enable/Disable Alarms COMMENT Enable/Disable alarm HOST S5,F3→ EQUIPMENT S5,F4 Figure 28 – Scenario: Host Enables or Disables Alarm COMMENT Equipment Acknowledges Upload Alarm Information COMMENT Request alarm data/text. HOST S5,F5→ EQUIPMENT S5,F6 COMMENT Send alarm data / text. Figure 29 – Scenario: Upload Alarm Information Alarm Detected By Equipment COMMENT HOST EQUIPMENT COMMENT S5,F1 Send Alarm Report if alarm is enabled. Acknowledge. S5,F2→ Figure 30 – Scenario: Alarm Occurrence Deleted By Equipment 4.6 Remote Control Host Sends Remote Command to Equipment COMMENT Host Command Send. HOST S2,F41→ EQUIPMENT S2,F42 COMMENT Host Command Acknowledge. Figure 31 – Scenario: Host Sends Remote Command to Equipment The following RCMDs are recognized by the equipment. Case is not significant, and dashes ‘-‘ may be substituted for underscores ‘_’. Note: Equipment will check previous equipment mode to decide accept remote command or not, when it is in Power Save or Power Restroation mode. Page - 60 - of 321 Sep 18, 2020 Rev 4.1 Kulicke & Soffa™ SECS/GEM Interface for K&S Ball Bonders Bonder software version x-xx-x-472-series Commands ACCEPT_IN_MAG ACCEPT_OUT_MAG CALC_PM_DATA RCMDs recognized by the equipment Description Arguments Positive response to equipmentRETMAGID – ID of initiated MHS_IN_BCR_SCAN the magazine at the collection event. Host decides that input position. the bar code and process program match, so equipment should process RETLOTID – ID of magazine. the lot for the input magazine. Positive response to equipmentRETMAGID – ID of initiated MHS_OUT_BCR_SCAN the magazine at the collection event. Host decides that output position. the bar code and process program match, so equipment should process RETLOTID – ID of magazine. the lot for the output magazine. Begin calculations of Production N/A Monitoring Data (see SVID’s 3500 – 3541/ 3597 – 3613/ 3618 – 3623/ 3626 – 3637). Equipment constants PM_StartTime and PM_StopTime must be set via S2 F15 prior to issuing this remote command. Equipment will notify host that data is ready via the collection event Process Monitoring Data Ready. ENTER_HIT Request equipment to enter Host Initiated Transfer Mode. N/A EXIT_HIT Request equipment to exit Host Initiated Transfer Mode. N/A Page - 61 - of 321 Sep 18, 2020 Rev 4.1 Kulicke & Soffa™ Note Equipment accepts this command in any mode except Motor Stop Mode. If the equipment received the command while in Auto: Run mode processing a device, the equipment completes processing the current device, and suspends device processing to perform the calculations of Production Monitoring Data. The equipment resumes device processing once the calculation is completed. Equipment only accepts this command when it is in Idle mode (i.e. none of the equipment operational mode is selected). SECS/GEM Interface for K&S Ball Bonders Bonder software version x-xx-x-472-series Commands INHIBIT_AUTO RCMDs recognized by the equipment Description Arguments Prevent the operator from entering N/A AUTO: RUN mode. Page - 62 - of 321 Sep 18, 2020 Rev 4.1 Kulicke & Soffa™ Note If the equipment is in AUTO:RUN processing a device when this command is received, the equipment completes processing the current device, returns to PROCESSING NOT ACTIVE process state, and enables Inhibit Auto: Run mode. Equipment remains in Inhibit Auto: Run mode until the RELEASE_INHIBIT_ AUTO remote command is received or when the equipment is rebooted. SECS/GEM Interface for K&S Ball Bonders Bonder software version x-xx-x-472-series OS_FILE_DWNLD Initiates downloading of equipment Operating Software N/A Page - 63 - of 321 Sep 18, 2020 Rev 4.1 Kulicke & Soffa™ 1. When the bonder receives the S2F41 (Host Command Send) message with a command parameter name of OS_FILE_DWNLD the command callback function performs the following in order: 2. Check initial conditions for accepting or rejecting the remote command. 3. Send the remote command acknowledge to the host. 4. Use Stream 13 messages to request the PACKAGE.INF file from the host. 5. Use the data in PACKAGE.INF to check for OS install/upgrade requirements. 6. Notify host if bonder does or does not meet the OS upgrade/installation requirements. Request the files needed for OS upgrade/installation if bonder meets the requirements. Upon completion of file download, the operator will be prompted with an OK/CANCEL dialog to complete the software installatio.7. The OS_FILE_DWNLD command will be rejected if the bonder operational mode is not in Idle (i.e. no operational mode is selected) or Standby. 8. The bonder will include in its reply to the command request the appropriate host command parameter SECS/GEM Interface for K&S Ball Bonders Bonder software version x-xx-x-472-series Commands RCMDs recognized by the equipment Description Arguments Prepare Process Program for upload. Equipment will notify host that program is ready (or an error occurred during preparation) via the collection event PP Upload and the status variables UploadPPStatus and UploadPPName. Load program into memory for Processing. Equipment will notify host that program has been successfully loaded via the collection event PP Select OK, or that an error occurred during loading via the collection event PP Select Failed. PPID – name of program to be uploaded, including the .BND extension PROCESS_START Start Process Remotely N/A REJECT_IN_MAG Negative response to equipmentinitiated MHS_IN_BCR_SCAN collection event. Host decides that the bar code and process program DO NOT match, so equipment should unload magazine. RETMAGID – ID of the magazine at the input position. PP_PREP PP_SELECT REJECT_OUT_MAG RELEASE_INHIBIT_AUTO RESET_PROD_COUNTERS Negative response to equipmentinitiated MHS_OUT_BCR_SCAN collection event. Host decides that the bar code and process program DO NOT match, so equipment should unload magazine. Disables Inhibit Auto: Run mode. Reset Status Variables Devices Processed and Devices Skipped to zero. PPID – name of program to be loaded, including the .BND extension RETLOTID – ID of the lot for the input magazine. RETMAGID – ID of the magazine at the output position. RETLOTID – ID of the lot for the output magazine. N/A N/A Page - 64 - of 321 Sep 18, 2020 Rev 4.1 Kulicke & Soffa™ Note acknowledge code listed below: 2 = Cannot perform now. Bonder is not in Idle (i.e. no operational mode is selected) or Standby mode. 4= Acknowledge; command will be performed. N. Equipment only accepts this command when it is in HIT mode. Equipment only accepts this command when it is in Idle mode (i.e. none of the equipment operational mode is selected). THE COMMAND WILL BE REJECTED IF THE WORKHOLDER IS NOT EMPTY. Need sign safety agreement, please contact KNS for more information SECS/GEM Interface for K&S Ball Bonders Bonder software version x-xx-x-472-series Commands STOP_PROCESSING MOVE_TO_IDLE LTO_ENABLE LTO_DISABLE INIT_LOT_SPEC RCMDs recognized by the equipment Description Arguments Request that the equipment pause N/A processing and enter the PAUSED process state. See section 4.3 Move machine to IDLE mode from N/A any mode other than equipment under below condition: 1. Equipment in Standby mode. 2. Equipment in AUTO:RUN mode. 3. Equipment in Heat Block teach mode. 4. Operation GUI display menu or dialog not support mapped MMI “Esc” hotkey. 5. Information/Warning/Error pop-up dialog showing up. Enable light tower override setting. N/A Disable light tower override setting. N/A Initialize lot data items. RETLOTID – Lot ID Name. MAG_NUM – Total Mag Number in Lot. Note Only applicable for bonder with Mag Handler Configuration SUBSTRAT E_NUM– Total Substrate Number in Lot. PPID– Current PPID for this Lot. ABORT_LOT Abort Current Lot and set to InActive Mode. START_LOT Start Current Lot and set to In-Active Mode. LOTOPID– Current Operator ID for this Lot. N/A N/A Page - 65 - of 321 Sep 18, 2020 Rev 4.1 Kulicke & Soffa™ Only applicable for bonder with Mag Handler Configuration Only applicable for bonder with Mag Handler Configuration SECS/GEM Interface for K&S Ball Bonders Bonder software version x-xx-x-472-series Commands JOG_EJECT_MAG RCMDs recognized by the equipment Description Arguments DO_MAG_CMD-remote magazine The DO_MAG_CMD operation CMD. has six values. I. 0JOG_IP UT_MA G means mhs to jog input mag. II. 1BJOG_I PUT_M AG means mhs to jog input mag reversel y. III. 2JOG_OP UT_MA G means mhs to jog output mag. IV. 3BJOG_ OPUT_ MAG means mhs to jog output mag reversel y. V. 4EJE_IP UT_MA G means mhs to eject input mag. VI. 5EJE_OP UT_MA G means mhs to eject output mag. Page - 66 - of 321 Sep 18, 2020 Rev 4.1 Kulicke & Soffa™ Note SECS/GEM Interface for K&S Ball Bonders Bonder software version x-xx-x-472-series Commands LF_IN_OUT LOAD_MGZ_CONFIRM CLEAR_MAG_ASSIST MAG_ID_SCAN_ACK RCMDs recognized by the equipment Description Arguments The LF_CMD has two values. DO_LF_CMD – LF_PULL_IN means mhs to pull in a remote lead frame new lead frame. LF_EJECT_OUT operation CMD. means mhs to eject the lead frame. The DO_LF_CMD has two values. LF_PULL_IN means mhs to pull in a new lead frame. LF_EJECT_OUT means mhs to eject the lead frame. Load magazine confirmation MGZ-ID and CONFIRM-FLAG. CONFIRM-FLAG has three options:T,F,H Clear Magazine Assist N/A Magazine ID Scan Acknowledge MAGTYPE, ACK and MAGID MAGTYPE has two options: INPUT and OUTPUT. ACK has three options: TRUE, FALSE and WAIT MAG_EJECT_HOST_VALI DATION Magazine Eject Host Validation One argument MAGTYPE, which has two options, INPUT and OUTPUT. Another argument ACK which has two options, GO and NOGO. N/A RESET_PBI_STATS Reset the PBI statistics DO_INDEX SUB_CONFIRM Do index Sub Confirm STOP RESET_STATS_SUMMAR Y RESET_TOOL_COUNTER RESET_WIRE_SPOOL Stop Remote reset statistics summary N/A SUB-ID and CONFIRM-FLAG. CONFIRM-FLAG has two options: T,F. N/A N/A Remote reset tool counter Remote reset wire spool N/A N/A Page - 67 - of 321 Sep 18, 2020 Rev 4.1 Kulicke & Soffa™ Note Equipment only accepts this command when it is not initializing or and PBI status GUI is not active SECS/GEM Interface for K&S Ball Bonders Bonder software version x-xx-x-472-series Commands COMPRESS_FILE INSPECTION_CONFIRM INSPECTION_PARA_INFO _SEND RCMDs recognized by the equipment Description Arguments Remote compress file or folder One argument FUNCTION – compress file function type. FUNCTION has one option: REAL_TIME_3RD_ OPT_IMAGES– real time 3RD optical inspection image file. LHM: Confirm inspection result SUB-ID and CONFIRM-FLAG. CONFIRM-FLAG has two options: T and F. LHM: Send inspection parameters. PARAM_COUNT PARAM_CD_1, SAMPLE_QTY_1, USL_1,LSL_1, UCL_1, LCL_1, PARAM_CD_2, LOAD_MGZ_LOT_CONFI RM Get lot id information. RETRIEVE_CURRPP_LAS TSAVED_TS Retrieve the last saved time stamp based on current active loaded process program PART_PROCESSED_RSLT _CONFIRM Perform part processed result validation Three arguments MAGTYPE, ACK and LOTID. MAGTYPE has two options: INPUT and OUTPUT. ACK has one option: TRUE. PP_SOURCE ( 0 means PP in Disk; 1 means PP in RAM; 2 means PP in RAM and Disk) 2 arguments 1. “ACK” Accept/reject “0”: accept result Others: reject result 2. “REASON” Detail reason. Page - 68 - of 321 Sep 18, 2020 Rev 4.1 Kulicke & Soffa™ Note Applicable for specific customer only. Please contact K&S for more information. Parameters will be applied to Loop ID (ECID 1751). It’s recommended to always set the Loop ID right before sending this RCMD. Applicable for specific customer only. Please contact K&S for more information. Applicable for specific customer only. Please contact K&S for more information. Applicable for specific customer only. Please contact K&S for more information. Applicable for specific customer only. Please contact K&S for more information. SECS/GEM Interface for K&S Ball Bonders Bonder software version x-xx-x-472-series Commands CHANGE_OVER_REQUES T TOOL_CHANGE_CONFIR M WIRE_CHANGE_CONFIR M RCMDs recognized by the equipment Description Arguments Request to start change over 5 arguments 1. “CONFIRMFLAG” Accept/reject “T”: accept changeover “F”: reject changeover Others: Invalid Value 2. “PARTSPER-CARRIER” Index Count 3. “PROGNAME” For productset up 4. “TOOLFAMILY” For productset up 5. “WIREPART-NO” For productset up Request to tool change 5 arguments 1. “ACK” Accept/reject “0”: accept Others: reject 2. “TOOL-ID” 3. “TOOLSTATE” “0”: OK “1”: Warning “2”: Block 4. “TOOLFAMILY” 5. “COUNTER ” Tool remaining counter Request to wire spool change 4 arguments 1. “ACK” Accept/reject “0”: accept Others: reject 2. “WIRE-ID” 3. “WIRESTATE” “0”: OK “1”: Warning “2”: Block 4. “WIREPART-NO” Page - 69 - of 321 Sep 18, 2020 Rev 4.1 Kulicke & Soffa™ Note Applicable for specific customer only. Please contact K&S for more information. Applicable for specific customer only. Please contact K&S for more information Applicable for specific customer only. Please contact K&S for more information SECS/GEM Interface for K&S Ball Bonders Bonder software version x-xx-x-472-series Commands RESET_PBI_WIRE_INSP_S TATS 4.7 RCMDs recognized by the equipment Description Arguments Wire Inspection: Reset wire inspection statistics Note Applicable for specific customer only. Please contact K&S for more information. Equipment Constants Host Sends Equipment Constants COMMENT Host sends equipment constants. HOST S2,F15→ EQUIPMENT COMMENT S2,F16 Equipment sets constants. Figure 32 – Scenario: Host Sends New Equipment Constant Value to the Host Host Equipment Constants Request COMMENT Host constant request. HOST S2,F13→ EQUIPMENT COMMENT S2,F14 Equipment constant data. Figure 33 – Scenario: Host Request Equipment Constant Value from Equipment Host Equipment Constants Namelist Request COMMENT Host constant namelist request. HOST S2,F29→ EQUIPMENT COMMENT S2,F30 Equipment constant namelist. Figure 34 – Scenario: Host Requests Equipment Constants Namelist 4.8 Process Programs The equipment supports uploads or downloads only of unformatted process programs. Process Program Deletion By Host COMMENT Delete Process Program Send. HOST S7,F17→ EQUIPMENT S7,F18 Figure 35 – Scenario: Host Requests Deletion of Process Program Host-Initiated Process Program Upload (Unformatted) Page - 70 - of 321 Sep 18, 2020 Rev 4.1 Kulicke & Soffa™ COMMENT Equipment must be in HIT mode. Delete Process Program acknowledge. SECS/GEM Interface for K&S Ball Bonders Bonder software version x-xx-x-472-series COMMENT Process Program Request. HOST S7,F5→ EQUIPMENT S7,F6 COMMENT Equipment responds with a zero length list. If in HIT mode, the Equipment prepares the process program for uploading by combining component files into a single zip file, else jump to end. S6,F11 Process Program Request. Equipment notifies host that process program is ready for uploading. S7,F5→ S7,F6 Figure 36 – Scenario: Host Initiated Process Program Upload. Page - 71 - of 321 Sep 18, 2020 Rev 4.1 Kulicke & Soffa™ Process Program Data. SECS/GEM Interface for K&S Ball Bonders Bonder software version x-xx-x-472-series COMMENT Remote Command PP_PREP. HOST S2,F41→ EQUIPMENT S2,F42 S6,F11 Process Program Request. COMMENT PPID specified as argument. If in HIT mode, equipment acknowledges command, else reject and jump to end. Equipment prepares the process program and notifies the host that the program is ready for uploading. S7,F5→ S7,F6 Process Program Data. Figure 37 – Scenario: Host Initiated PP Upload using PP_PREP remote command. When the equipment receives an S7,F5 Process Program Request (PPR) message, it replies with a S7,F6 Process Program Data (PPD) message. If the equipment is 1) not in Host Initiated Transfer (HIT) mode or 2) is unable to upload the requested process program or, 3) the program has not been prepared for upload but the control context is HIT, then the equipment will send the S7,F6 Process Program Data (PPD) message with a zero-length list. In case 3) above, the equipment will proceed to combine the process program components into a single file and notify the host with a S6,F11 at completion of the preparation for upload. On receiving the S6,F11, the host can repeat the upload request and the process program will be sent. The remote command PP_PREP, with the PPID specified, prompts the equipment to prepare the process program for upload, with the S6,F11 sent by the equipment (if the equipment is in HIT mode) at the completion of the preparation for upload. The host can then send the S7,F5 and expect an immediate S7,F6 response (if the equipment remains in HIT mode). Equipment-Initiated Process Program Download (Unformatted) COMMENT HOST EQUIPMENT COMMENT S7,F5 Process Program Request Process Program Data S7,F6→ Figure 38 – Scenario: Equipment Initiated Process Program Download Process Program Directory Request COMMENT Current EPPD Request. HOST S7,F19→ EQUIPMENT S7,F20 Figure 39 – Scenario: Process Program Directory Request COMMENT Equipment must be in HIT mode. Current EPPD Data. The host can determine which process programs exist on the equipment. When the equipment receives an S7,F19 Current EPPD Request (RER) message from the host, it replies with an S7,F20 Current EPPD Data (RED) message. If the equipment accepts the S7,F19 Current EPPD Request (RER) message, then an S7,F20 Current EPPD Data (RED) message containing a list of the process programs stored at the equipment will be returned. If the message is rejected, then the S7,F20 Current EPPD Data (RED) message will contain a zero-length list. Host-Initiated Process Program Download (Unformatted) Page - 72 - of 321 Sep 18, 2020 Rev 4.1 Kulicke & Soffa™ SECS/GEM Interface for K&S Ball Bonders Bonder software version x-xx-x-472-series COMMENT If process program is multi-block and DisableProcessProgramLoadIn quire is false, then send Process Program Load Inquire. Specify exact filename and file size in bytes. HOST S7,F1→ Process Program Send. EQUIPMENT COMMENT Equipment must be in HIT mode. S7,F2 Process Program Load Grant S7,F4 S6,F11 Process Program Acknowledge. Equipment sends an event report to host S7,F3→ Figure 40 – Scenario: Host-Initiated Process Program Download. If the host is attempting to download a multi-block process program to the equipment, then an S7,F1 Process Program Load Inquire (PPI) and S7,F2 Process Program Load Grant (PPG) transaction must precede the process program download. When the equipment receives an S7,F1 message from the host, the equipment will respond with an S7,F2 PPGNT. If the download is granted by the equipment, the host can send the S7,F3 Process Program Send (PPS) message containing the unformatted process program. The equipment will respond with an S7,F4 ACKC7. Once the equipment has verified the downloaded program, the results of the verification will be stored in the status variable DownloadPPStatus, and the collection event PP Download will be sent to the host. Equipment-Initiated Process Program Upload (Unformatted) COMMENT Process Program Load Grant. HOST EQUIPMENT COMMENT S7,F1 If the process program is multiblock and DisableProcessProgramLoadIn quire is false, then send Process Program Load Inquire. S7,F2→ S7,F3 Process Program Send. Process Program Acknowledge. S7,F4→ Figure 41 – Scenario: Equipment-Initiated Process Program Upload - Unformatted 4.9 Terminal Services The equipment terminal services will allow for the host to display information on the equipment’s display devices. Host Sends Information to Equipment’s Display Device COMMENT Host sends textual information to equipment for display to operator at terminal x. HOST S10,F3→ EQUIPMENT COMMENT S10, F4 Equipment acknowledges request to display text. Figure 42 – Scenario: Host Sends Information to Equipment’s Display Device There are three types terminal message. Single-Type Terminal Message (TID = 0, 1, 2, 3). ❖ 0 = Standard message ❖ 1 = Message immediate display ❖ 2 = Message immediate display - dialog box has colored label ❖ 3 = Message immediate display - dialog box has colored label, Alarm/beep, Light tower blinks Yellow Persistent-Type Terminal Message (TID =10, 11, 12, 13). It would be hold until a new message arrives to overwrite it. Page - 73 - of 321 Sep 18, 2020 Rev 4.1 Kulicke & Soffa™ SECS/GEM Interface for K&S Ball Bonders Bonder software version x-xx-x-472-series ❖ 10 = Standard message ❖ 11 = Message immediate display ❖ 12 = Message immediate display - dialog box has colored label ❖ 13 = Message immediate display - dialog box has colored label, Alarm/beep, Light tower blinks Yellow. Multiple-Type Terminal Messages (TID = 20, 21, 22, 23). Equipment maintains a message buffer to hold on message. Equipment will reject coming message (ACKC10 = 1 - Message will not be displayed) if the maximum number of buffered message is reached. In the equipment GUI, user could be able to view the previous and next message, and delete any one he wants. ❖ 20 = Standard message ❖ 21 = Message immediate display ❖ 22 = Message immediate display - dialog box has colored label 23 = Done Disabled; Message immediate display - dialog box has colored label, Alarm/beep, Light tower blinks Yellow. Host Sends Multi-block Message to Equipment’s Display Device COMMENT Host sends textual information to equipment for display to operator at terminal x. HOST S10,F5→ EQUIPMENT COMMENT S10, F6 Equipment acknowledges request to display text. Figure 43 – Scenario: Host Sends Multi-block Message to Equipment Display Operator Sends Information to Host COMMENT Operator sends textual information via equipment terminal x. EQUIPMENT S10,F1→ HOST S10, F2 Page - 74 - of 321 Sep 18, 2020 Rev 4.1 Kulicke & Soffa™ COMMENT Host acknowledges receipt of operator imitated message. SECS/GEM Interface for K&S Ball Bonders Bonder software version x-xx-x-472-series 4.10 Strip Map The equipment supports stream 14 messages as defined by the SEMI E30 standard. (Premium Option) Strip Map standard implementation shall use the SECS/GEM standard Object Services (S14, F1/F2) and standard Collection Event S6, F11/F12 Streams and Functions for the transfer of Strip Maps to and from equipment. Get Strip Map Attribute Data The equipment requests a strip map download from the host using the Standard Object Services (OSS) command, S14, F1 GetAttribute Request (GAR). The host will respond to the GetAttribute Request with an S14F2, Get Attribute Data (GAD). COMMENT EQUIPMENT HOST COMMENT Equipment sends a message with S14,F1→ OBJSPEC(KNS), OBJTYPE(Strip Map), OBJID(StripID) and ATTRID(Rows/Columns/OriginLo cation/LotID/CellStatus). S14, F2 Host acknowledges requested data with corresponding OBJID data items and desired OBJACK. S14,F1 Sample Message Page - 75 - of 321 Sep 18, 2020 Rev 4.1 Kulicke & Soffa™ SECS/GEM Interface for K&S Ball Bonders Bonder software version x-xx-x-472-series Item GUI Configuration Map Data Request Message S14F1 Page - 76 - of 321 Sep 18, 2020 Rev 4.1 Kulicke & Soffa™ Map Data Reply Message S14F2 SECS/GEM Interface for K&S Ball Bonders Bonder software version x-xx-x-472-series 1 Cell Status Only S14F1 (WB) ---<L [5] ------<A [3] KNS> ------<A [8] StripMap> ------<L [1] ---------<A [7] StripID> ------> ------<L [0]> ------<L [5] ---------<A [4] Rows> ---------<A [7] Columns> ---------<A [14] OriginLocation> ---------<A [5] LotID> ---------<A [10] CellStatus> ------> ---> Page - 77 - of 321 Sep 18, 2020 Rev 4.1 Kulicke & Soffa™ S14F2 (Host) < L,2 < L,1 < L,2 < A[11] 'tempStripID'> < L,5 < L,2 < A[4] 'Rows'> < U4 1> > < L,2 < A[7] 'Columns'> < U4 5> > < L,2 < A[14] 'OriginLocatio n'> < U1 1> > < L,2 < A[5] 'LotID'> < A[9] 'TestLotID'> > < L,2 < A[10] 'CellStatus'> < L,5 < U1 0> < U1 0> < U1 0> < U1 0> < U1 0> > > > > > < L,2 < U1 0> < L,0 > > > SECS/GEM Interface for K&S Ball Bonders Bonder software version x-xx-x-472-series 2 Cell Grade Only S14F1 (WB) ---<L [5] ------<A [3] KNS> ------<A [8] StripMap> ------<L [1] ---------<A [7] StripID> ------> ------<L [0]> ------<L [5] ---------<A [4] Rows> ---------<A [7] Columns> ---------<A [14] OriginLocation> ---------<A [5] LotID> ---------<A [9] CellGrade> ------> ---> Page - 78 - of 321 Sep 18, 2020 Rev 4.1 Kulicke & Soffa™ S14F2 (Host) < L,2 < L,1 < L,2 < A[11] 'tempStripID'> < L,5 < L,2 < A[4] 'Rows'> < U4 1> > < L,2 < A[7] 'Columns'> < U4 5> > < L,2 < A[14] 'OriginLocatio n'> < U1 1> > < L,2 < A[5] 'LotID'> < A[9] 'TestLotID'> > < L,2 < A[10] 'CellGrade'> < L,5 < U1 11> < U1 11> < U1 11> < U1 11> < U1 11> > > > > > < L,2 < U1 0> < L,0 > > > SECS/GEM Interface for K&S Ball Bonders Bonder software version x-xx-x-472-series 3 Cell Status & Cell Grade S14F1 (WB) ---<L [5] ------<A [3] KNS> ------<A [8] StripMap> ------<L [1] ---------<A [7] StripID> ------> ------<L [0]> ------<L [6] ---------<A [4] Rows> ---------<A [7] Columns> ---------<A [14] OriginLocation> ---------<A [5] LotID> ---------<A [10] CellStatus> ---------<A [9] CellGrade> ------> ---> Page - 79 - of 321 Sep 18, 2020 Rev 4.1 Kulicke & Soffa™ S14F2 (Host) < L,2 < L,1 < L,2 < A[7] 'StripID'> < L,6 < L,2 < A[4] 'Rows'> < U4 1> > < L,2 < A[7] 'Columns'> < U4 5> > < L,2 < A[14] 'OriginLocatio n'> < U1 1> > < L,2 < A[5] 'LotID'> < A[3] 'abc'> > < L,2 < A[10] 'CellStatus'> < L,5 < U1 2> < U1 2> < U1 2> < U1 2> < U1 2> > > < L,2 < A[9] 'CellGrade'> < L,5 < U1 11> < U1 11> SECS/GEM Interface for K&S Ball Bonders Bonder software version x-xx-x-472-series < U1 11> U1 11> U1 11> < < > > > > > < L,2 < U1 < L,0 > > > S14,F2 Sample Message Page - 80 - of 321 Sep 18, 2020 Rev 4.1 Kulicke & Soffa™ 0> SECS/GEM Interface for K&S Ball Bonders Bonder software version x-xx-x-472-series Item 1 OBJACK Setting OBJACK = 0 Map Data Reply Message S14F2 < L,2 < L,1 < L,2 < A[7] 'StripID'> < L,6 < L,2 < A[4] 'Rows'> < U4 1> > < L,2 < A[7] 'Columns'> < U4 5> > < L,2 < A[14] 'OriginLocation'> < U1 1> > < L,2 < A[5] 'LotID'> < A[3] 'abc'> > < L,2 < A[10] 'CellStatus'> < L,5 < U1 2> < U1 2> < U1 2> < U1 2> < U1 2> > > < L,2 < A[9] 'CellGrade'> < L,5 < U1 11> < U1 11> < U1 11> < U1 11> < U1 11> > > > > > < L,2 < U1 0> < L,1 < L,2 < U2 0> < A[0] ''> > > > > Page - 81 - of 321 Sep 18, 2020 Rev 4.1 Kulicke & Soffa™ SECS/GEM Interface for K&S Ball Bonders Bonder software version x-xx-x-472-series 2 OBJACK = 1 Host wants to reject a particular substrate and wants bonder to prompt Error#2250 STRIP_MAP_HOST_REPLY_ERROR Note: ERRCODE, ERRTEXT can be leave as empty < L,2 < L,1 < L,2 < A[11] 'tempStripID'> < L,6 < L,2 < A[4] 'Rows'> < U4 1> > < L,2 < A[7] 'Columns'> < U4 5> > < L,2 < A[14] 'OriginLocation'> < U1 1> > < L,2 < A[5] 'LotID'> < A[3] 'abc'> > < L,2 < A[10] 'CellStatus'> < L,5 < U1 0> < U1 0> < U1 0> < U1 0> < U1 0> > > < L,2 < A[9] 'CellGrade'> < L,5 < U1 11> < U1 11> < U1 11> < U1 11> < U1 11> > > > > > < L,2 < U1 1> < L,1 < L,2 < U2 0> < A[0] ''> > > > > Query Cell Status/Cell Grade Data Page - 82 - of 321 Sep 18, 2020 Rev 4.1 Kulicke & Soffa™ SECS/GEM Interface for K&S Ball Bonders Bonder software version x-xx-x-472-series Strip Map data upload can be retrieved either via S6F11 report or SVID inqury stream S1F3/F4. COMMENT EQUIPMENT HOST COMMENT Once cell status/cell grade S6,F11→ variables updated, equipment sends CEID 8336. S1, F3 Host receives the event and query corresponding cell status/cell grade data. Equipment sends the data to host. 4.11 S1, F4→ Host receives the queried data. Job Control The equipment supports stream function as defined by the SEMI E5 (Equipment Communications Standard), E87 (carrier management), E40 (Processing management), and E94 (control job management) to realize production automation control by factory host. (Premium Option) S3F17/S3F18 Stream Function S3F17/S3F18 – carrier action request Page - 83 - of 321 Sep 18, 2020 Rev 4.1 Kulicke & Soffa™ SECS/GEM Interface for K&S Ball Bonders Bonder software version x-xx-x-472-series Data DATAID CARRIERACTION Description Data ID Specifies the action requested for a carrier CARRIERID The identifier of a carrier PORT Port ID Capacity Maximum number of substrates a carrier can hold SubstrateCount The number of substrates currently in the carrier Usage The type of material contained in the carrier Ordered list of slot status as provided by host and corresponding to slot 1,2,3…n until a successful slot map read, then as read by equipment. SlotMap UNDEFINED – 0 EMPTY – 1 NOT EMPTY – 2 CORRECTLY OCCUPIED – 3 DOUBLESLOTTED – 4 CROSS SLOTTED – 5 ContentMap Ordered list of a lot and substrate identifiers corresponding to slot 1,2,3,…n Remark will not use this data Only support Bind, ProceedWithCarrier(for ID verification), CancelCarrier Use it to do CarrierID Verification. Only support 1 for input loadport and 4 for output loadport, other numbers are invalid Will use it to check whether SlotMap/ContentMap count is right or not Will use it to check whether presence data in slotmap is right or not Will not use Due to hardware limitation, slotmap verification will not be performed. But will use this slotmap to check whether need to pull in L/F from the slot. So provided carrier slot status must match the slotmap. Otherwise incorrect error info will be reported when pulling L/F. Will only use substrate id when substrate verification after substrate id scan. S14F9/S14F10 Stream Function S14F9/S14F10 – create control job request Per semi e94, the process jobs specified for a control job must exist prior to calling create control job. Otherwise, bonder will report fail for this create control job request. Page - 84 - of 321 Sep 18, 2020 Rev 4.1 Kulicke & Soffa™ SECS/GEM Interface for K&S Ball Bonders Bonder software version x-xx-x-472-series Data OBJSPEC Description A text string that has an internal format and that is used to point to a specific object instance. Identifier for a group or class of objects OBJTYPE (Must be ControlJob) ATTRID (Identifier for an attribute for a specific type of object) ObjID Host defined identifier of the control job ProcessingCtrlSpec Define the method for the order in which process jobs are initiated A list of carrierID for material that will be used by ControlJob. CarrierInputSpec MtrlOutSpec Maps material from source to destination after processing. ProcessOrderMgmt Define the method for the order in which process jobs are initiated. StartMethod A logical flag that determines if the ControlJob can start automatically. Remark Will not use this data. This must be set as ControlJob to indicate this is control job creation Will use this attribute data as control job id, this data is required. Only support 1 process job. Only one CarrierID is supported. And the carrierID must equal to the CarrierInputSpec in process job definition of above ProcessingCtrlSpec. Will not use this data. Follows the PP definition. And must fill in L,0 for this attribute Will only support 1=ARRIVAL, process jobs shall be initiated as the related material arrives and passes verification. Can only support TRUE – Auto, which means when material comes, bonder will start control job. S16F15/S16F16 Stream Function S16F15/S16F16 – create multiple process job request Currently ball bonder only supports one process job to be queued and one process job to be executed. So only one process job can be created with this request to queue the process job. Data DATAID PRJOBID Description Data ID Text string which uniquely identifies a process job MF Material format code 1 byte by Format 10. Page - 85 - of 321 Sep 18, 2020 Rev 4.1 Kulicke & Soffa™ Remark Will not use this data. Will use this data. When bonder sends process job state change to host, this data is required Only support value=13 (Quantities SECS/GEM Interface for K&S Ball Bonders Bonder software version x-xx-x-472-series CARRIERID The identifier of a carrier. SLOTID Used to reference material by slot in a carrier. Indicates the recipe specification type, whether tuning is applied and which method is used. Recipe specifier. The object specifier of a recipe. PRRECIPEMETHOD RCPSPEC RCPPARNM The name of a recipe variable parameter RCPPARVAL The initial setting assigned to a recipe variable parameter. PRPROCESSSTART Indicates that the process resource start processing immediately when ready. PRPAUSEEVENT The list of event identifiers which may be sent as an attribute value to a process job. When a process job encounter one of these events it will pause, until it receives the PRJobCommand RESUME. Page - 86 - of 321 Sep 18, 2020 Rev 4.1 Kulicke & Soffa™ in carriers) according to customer provided example. Will use this data to know whether the material using this process job. Will not use. 1,2,….n as slot sequence. Only support value=1 recipe only PP name. Will use it since process job status update need this info. Will not use now since we do not support parameter tuning now Will not use now since we do not support parameter tuning now Only support TRUE=AutoStart as customer provided flow. Will not use now. SECS/GEM Interface for K&S Ball Bonders Bonder software version x-xx-x-472-series S16F21/S16F22 Stream Function S16F21/S16F22 – Get the number of process jobs bonder has space to create Data Description Remark PRJOBSPACE(ACK) The number of process jobs that can be If no process job in the created. queue, returns 1 to host. Otherwise returns 0 to host. S16F27/S16F28 Stream Function S16F27/S16F28 – Control Job Command Request / Control Job Command Acknowledge Data Description Remark CTLJOBID Identifier for Control Job. Conforms to Use this data to check OBJID which control job is required to be processed. CTLJOBCMD Control Job Command codes are Only support assigned as follows. 7=CJAbort now to 1 = CJStart abort queued control 2 = CJPause job or active control 3 = CJResume job 4 = CJCancel 5 = CJDeselect 6 = CJStop 7 = CJAbort 8 = CJHOQ CPNAME Command Parameter Name Since only CJAbort is supported, it needs fill CPNAME as “Action”. CPVAL Command Parameter Value It indicates value of “Action”. SAVEJOBS(=0) and REMOVEJOBS(=1) are supported. It only affects process jobs that are in QUEUED state. S16F5/S16F6 Stream Function S16F5/S16F6 – Process Job Command Request/Acknowledge Page - 87 - of 321 Sep 18, 2020 Rev 4.1 Kulicke & Soffa™ SECS/GEM Interface for K&S Ball Bonders Bonder software version x-xx-x-472-series 4.12 Calibration Result Data Object service standard provide an easy and flexible approach to get a collection of data. Each calibration result is a collection of sub calibration data. Get Calibration Data Host could retrieve calibration results through S14F1.With empty the attribute filter; they can retrieve certain calibration result through setting the OBJID. If not specified OBJID, they will get all calibration results. Page - 88 - of 321 Sep 18, 2020 Rev 4.1 Kulicke & Soffa™ SECS/GEM Interface for K&S Ball Bonders Bonder software version x-xx-x-472-series COMMENT Host sends a message with OBJSPEC(KNS), OBJTYPE(CalibrationResults), OBJID(Corresponding to calibration name) and ATTRID(CalStatus/CalTime/ CalData). EQUIPMENT S14,F1→ HOST S14, F2 COMMENT Equipment acknowledges requested data with corresponding OBJID data items and desired OBJACK. Calibration Results Object Attribute Table Attribute Name OBJID OBJTYPE CalStatus CalTime CalData Definition Type Corresponding to calibration name, refer to Table 4-2 Object type. Calibration status text SECSGEM Type ASCII text enumerated ASCII U2 Calibration time Calibration data of certain calibration text list ASCII List Page - 89 - of 321 Sep 18, 2020 Rev 4.1 Kulicke & Soffa™ Value “CalibrationResults” UNKNOWN - not yet done (0) OK - done(1), NOT GOOD- done(2), DEFAULT-(3) SECS/GEM Interface for K&S Ball Bonders Bonder software version x-xx-x-472-series Calibration Name and OBJID Mapping Calibration Name OBJID Servo Tune X Axis Calibration CAL_SERVO_X_FF Servo Tune Y Axis Calibration CAL_SERVO_Y_FF Servo_z_ff Calibration CAL_SERVO_Z_FF Servo_z_fb Calibration CAL_SERVO_Z_FB PRS Calibration CAL_PRS Cross-Hair Offset CAL_XHAIR_OFFSET Wand Height Calibration CAL_WAND_HT Copper Wand Calibration CAL_COPPER_WAND_HT USG Calibration CAL_USG Bond Force Calibration CAL_BOND_FORCE MHS Rail Z Calibration CAL_RAIL_Z Puller Sensor Calibration CAL_ATX3_PULLER_HALL_SNS Indexer Gripper Sensor Calibration CAL_ATX3_INDEX_HALL_SNS Index Gripping Force Calibration CAL_ATX3_INDEX_CLG_FORCE Eject Gripper Sensor Calibration CAL_ATX3_EJECT_HALL_SNS Eject Gripping Force Calibration CAL_ATX3_EJECT_CLG_FORCE Indexer Calibration CAL_INDEXER MHS Xsensor Calibration CAL_XSENSOR Input Wall Sensor Calibration CAL_IN_WALL Output Wall Sensor Calibration CAL_OUT_WALL MHS Rail Calibration CAL_RAIL MHS Clamp Calibration CAL_CLAMP Input Tray Calibration CAL_INTRAY Output Tray Calibration CAL_OUTTRAY Input Slot Calibration CAL_INSLOT Output Slot Calibration CAL_OUTSLOT Y Sensor Offset Calibration CAL_Y_SENSOR_OFFSET Temperature Control CAL_TEMPCONTB1 Jam Detect Calibration CAL_JDC CAL JDC Sample: Page - 90 - of 321 Sep 18, 2020 Rev 4.1 Kulicke & Soffa™ SECS/GEM Interface for K&S Ball Bonders Bonder software version x-xx-x-472-series Content of Attribute “CalData” “CalData” is a set of calibration data items. Each calibration data item composed of name and value. L, n # n = number of calibration data items 1. L, 2 1. <name> 2. <value> . . n. L, 2 1. <name> 2. <value> The following tables list the calibration data items of each calibration. You can get the name, the value type and description of them. Page - 91 - of 321 Sep 18, 2020 Rev 4.1 Kulicke & Soffa™ SECS/GEM Interface for K&S Ball Bonders Bonder software version x-xx-x-472-series 4.13 Error Messages The equipment supports stream 9 messages as required by the SEMI E30 standard. Message Fault Due to Unrecognized Device ID COMMENT Host sends a message with a device ID not recognized by the equipment. HOST Sx,Fy→ EQUIPMENT COMMENT S9,F1 Equipment reports to the host that an unrecognized device ID was received. Figure 44 – Scenario: Message Fault Due to Unrecognized Device ID Message Fault Due to Unrecognized Stream Type COMMENT Host sends a message containing a stream type not recognized by the equipment. HOST Sx,Fy→ EQUIPMENT COMMENT S9,F3 Equipment reports to the host that an unrecognized stream type was received. Figure 45 – Scenario: Message Fault Due to Unrecognized Stream Type Message Fault Due to Unrecognized Function Type COMMENT Host sends a message containing a function type not recognized by the equipment. HOST Sx,Fy→ EQUIPMENT COMMENT S9,F5 Equipment reports to the host that an unrecognized function type was received. Figure 46 – Scenario: Message Fault Due to Unrecognized Function Type Message Fault Due to Illegal Data Format COMMENT Host sends an incorrectly formatted message to the equipment. HOST Sx,Fy→ EQUIPMENT S9,F7 COMMENT Equipment reports to the host that a message was received containing an illegal data format. Figure 47 – Scenario: Message Fault Due to Illegal Data Format Message Fault Due to Transaction Timer Timeout COMMENT HOST EQUIPMENT COMMENT Sx,Fy Equipment sends a primary message requiring a reply to the host. Reply is not received within the configured period; transaction timer timeout occurs. S9,F9 Equipment reports a transaction timer timeout. Figure 48 – Scenario: Message Fault Due to Transaction Timer Timeout Page - 92 - of 321 Sep 18, 2020 Rev 4.1 Kulicke & Soffa™ SECS/GEM Interface for K&S Ball Bonders Bonder software version x-xx-x-472-series 4.14 Spooling The equipment will support the GEM Spool State Model as described by the SEMI E30 standard. Spooling State Model SPOOLING SPOOL ACTIVE SPOOL OUTPUT H* PURGE SPOOL TRANSMIT SPOOL 3 4 8 POWER OFF SPOOL INACTIVE 1 7 SPOOL UNLOAD 5/6 NO SPOOL OUTPUT SPOOL LOAD SPOOL FULL 2 SPOOL NOT FULL POWER ON Figure 49 - GEM Spooling State Model Spooling State Transitions Page - 93 - of 321 Sep 18, 2020 Rev 4.1 Kulicke & Soffa™ SECS/GEM Interface for K&S Ball Bonders Bonder software version x-xx-x-472-series # CURRENT STATE TRIGGER EVENT NEW STATE ACTION COMMENT 1 SPOOL INACTIVE Communication failure detected SPOOL ACTIVE SpoolCountActual and SpoolCountTotal are initialized to zero. Any open transactions with the host are aborted. SpoolStartTime (SV) is set to current time. Alert the operator that spooling is active The default state in each OR substate is entered. The message which could not be sent remains in the send queue and is dealt within Spool Active state. The collection event Spooling Activated has occurred 2 SPOOL NOT FULL Message generate which will not fit into spool area SPOOL FULL SpoolFullTime (SV) is set to current time. Alert the operator that spool is full The message which would not fit into the spooling area is dealt with after the transition. No collection event is generated 3 SPOOLOUTPU T Spool area emptied SPOOL INACTIVE Spooling process disabled. Alert the operator that spooling has been terminated The collection event Spooling Deactivated has occurred. Transition from the OR substate Spool Load component occurs 4 NO SPOOLOUTPU T S6,F23 received w/RSDC=1 PURGE SPOOL No action Initiates purging process. No collection event is generated since this is based on host request 5 NO SPOOLOUTPU T S6,F23 received w/ RSCD=0 TRANSMIT SPOOL No action Initiates message transmission from spool. No collection event is generated since this is based on host request 6 TRANSMITSP OOL Comm. failure or MaxSpool Transmit reached NO SPOOL OUTPUT Spool transmission process suspended If communications failure, the event Spool Transmit Failure has occurred. No collection event generated for MaxSpoolTransmit reached 7 POWER ON Equipment power source discontinued POWER OFF No action Spooling context has been maintained in non-volatile storage prior to this transition 8 POWEROFF Equipment power source restored POWER ON Spooling context restored from non-volatile memory If spooling were active prior to power down, it shall continue. If TRANSMIT SPOOL were active at power down, transition #6 is expected to follow since communications state is initially NOT COMMUNICATING Host Defines Set of Messages to be Spooled COMMENT Host defines messages to be spooled in case of communications failure. HOST S2,F43→ EQUIPMENT COMMENT S2,F44 Equipment acknowledges setup. Figure 50 – Scenario: Host Defines Set of Messages to be Spooled Define Maximum Number of Messages to Send in Response to S6,F23 COMMENT Host sends value for equipment constant MaxSpoolTransmit. HOST S2,F15→ EQUIPMENT S2,F16 COMMENT Equipment acknowledges equipment constant change. Figure 51 – Scenario: Host Defines Maximum Number of Messages to be Sent Request and Delete Spooled Data Page - 94 - of 321 Sep 18, 2020 Rev 4.1 Kulicke & Soffa™ SECS/GEM Interface for K&S Ball Bonders Bonder software version x-xx-x-472-series COMMENT Host Requests data that includes spool related status variables. If MaxSpoolTransmit not 0, request spooled data. Delete spooled data. HOST EQUIPMENT COMMENT S1,F3→ S1,F4 Send status data. S6,F24 Request/delete spooled data acknowledgment. S6,F24 Request/delete spooled data acknowledgment. S6,F23→ S6,F23→ Figure 52 – Scenario: Request and Delete Spooled Data 4.15 Automated Material Movement Management AGV/OHT Auto Handling System Sequence (Premium Option) AGV/OHT gets empty magazine AGV/OHT puts unbonded magazine AGV/OHT puts empty magazine AGV/OHT gets bonded magazine Figure 53 – AGV/OHT Action Action 1 Loading Tray at Input Magazine Handler Operation Sequence 1. Check that there is a (unbonded) magazine on the loading tray. Bonder waits for magazine to be loaded. A wait message prompt appears. • If a magazine is loaded, continue with the operation • If the user selects Abort, the operation terminates 2. The loading belt turns on. 3. The (unbonded) magazine moves to grip position. 4. The bonder signals the host for Load Port Status Changed. 5. The benching kit activates. 6. After a delay time, the benching kit de-activates. 7. The Z tower grips the magazine and moves to slot position. Page - 95 - of 321 Sep 18, 2020 Rev 4.1 Kulicke & Soffa™ SECS/GEM Interface for K&S Ball Bonders Bonder software version x-xx-x-472-series Action 2 Unloading Tray at Input Magazine Handler Operation Sequence 1. Check that the unloading tray is empty. If (empty) magazine present, machine waits for magazine to be removed. A wait message prompt appears. • If the AGV removes the magazine from the tray, continue with the operation • If you select Abort, the operation terminates 2. The loading belt turns on. 3. Check the status of the upper tray sensor. 4. The bonder signals the host for Unload Port Status Changed. Action 3 Loading Tray at Output Magazine Handler Operation Sequence 1. Check that there is an empty magazine on the loading tray. Bonder waits for magazine to be loaded. • If there is no magazine present on tray, a wait message prompt appears. If user selects Abort in wait message, the operation terminates • If magazine (from unloading tray at Input Magazine Handler) is put on the tray, continue with the operation 2. The loading belt turns on. 3. The (empty) magazine moves to grip position. 4. The bonder signals the host for Load Port Status Changed. 5. The benching kit activates. 6. After a delay time, the benching kit de-activates. The Z tower grips the magazine and moves to slot position. Action 4 Operation Sequence Unloading Tray at Output Magazine Handler 1. Check that the unloading tray is empty. If (bonded) magazine present, machine waits for magazine to be removed. • If there is a (bonded) magazine present on tray, a wait message prompt appears. If user selects Abort in wait message, the operation terminates Page - 96 - of 321 Sep 18, 2020 Rev 4.1 Kulicke & Soffa™ SECS/GEM Interface for K&S Ball Bonders Bonder software version x-xx-x-472-series • If the AGV removes the magazine from the tray, continue with the operation 2. The loading belt turns on. 3. Check the status of the lower tray sensor. 4. The bonder signals the host for Unload Port Status Changed. Page - 97 - of 321 Sep 18, 2020 Rev 4.1 Kulicke & Soffa™ SECS/GEM Interface for K&S Ball Bonders Bonder software version x-xx-x-472-series KNS Bonder to Host Events And Applicable SVID Sensor/Button IMH load sensor tray’s CEID SVID outer 8402 ML_Load_Port_Status_Changed 3817 ML_Load_Port_Status IMH unload tray’s outer 8403 ML_Unload_Port_Status_Changed sensor 3818 ML_Unload_Port_Status OMH load tray’s outer 8404 MR_Load_Port_Status_Changed sensor 3819 MR_Load_Port_Status OMH unload tray’s outer 8405 MR_Unload_Port_Status_Changed sensor 3820 MR_Unload_Port_Status IMH load tray’s inner limit 8409 ML_Load_Limit_Sns_Status_Changed sensor 3823 ML_Load_Limit_Sns_Status OMH load tray’s inner limit 8410 MR_Load_Limit_Sns_Status_Changed sensor 3824 MR_Load_Limit_Sns_Status 4.16 Enhanced Operator Data Entry Overview The existing Operator Entry dialog has been expanded with additional status variable and collection event fields, each with a corresponding label that can be set using an equipment constant. With this enhanced capability, the host system can implement up to four additional operator events as needed. Refresh of the Operator Entry dialogs will not occur while the dialogs are being displayed. If the host system changes a field label, the change will not become apparent to the operator until the dialog is re-displayed. Operator Data Entry #1 Dialog - Host Definable Items Entry Label EC Value Assoc. Label Default EC Value # ECID Format SVID 1 1332 A[15] “Enter_Data_A” 3032 2 1333 A[15] “Enter_Data_B” 3033 3 1334 A[15] “Enter_Operator_” 3034 4 1822 A[30] “Send_Operator_Event” Figure 54 – Host Defineable Operator Entry #1 Dialog Items Operator Data Entry #2 Dialog - Host Definable Items Page - 98 - of 321 Sep 18, 2020 Rev 4.1 Kulicke & Soffa™ SV Value Format A[80] A[80] A[80] - Default SV Value NULL string NULL string NULL string - CEID 8022 SECS/GEM Interface for K&S Ball Bonders Bonder software version x-xx-x-472-series Entry Label EC Value Assoc. Label Default EC Value # ECID Format SVID 1 1391 A[15] “Enter_SV_3091” 3091 2 1392 A[15] “Enter_SV_3092” 3092 3 1393 A[15] “Enter_SV_3094” 3093 4 1394 A[15] “Enter_SV_3095” 3094 5 1891 A[30] “Send_CE_8091” 6 1892 A[30] “Send_CE_8092” 7 1893 A[30] “Send_CE_8093” 8 1894 A[30] “Send_CE_8094” Figure 55 – Host Defineable Operator Entry #2 Dialog Items Page - 99 - of 321 Sep 18, 2020 Rev 4.1 Kulicke & Soffa™ SV Value Format A[80] A[80] A[80] A[80] - Default SV Value NULL string NULL string NULL string NULL string - CEID 8091 8092 8093 8094 SECS/GEM Interface for K&S Ball Bonders Bonder software version x-xx-x-472-series 4.17 OS File Download Scenario for Remote Installation Once the bonder has acknowledged that the command OS_FILE_DWNLD will be performed, it will request the PACKAGE.INF file from the factory automation host system by initiating the OPEN, READ, and CLOSE transactions. The file download scenario using the functions of Stream 13 is shown in the table below. HOST S2F41 (Host Command Send) ---- BONDER <---- (Host Command Ack) S2,F42 <---- (Open Data Set Request) S13,F3 S13,F4 (Open Data Set Data) ---<---- (Read Data Set Request) S13,F5 S13,F6 (read Data Set Data) ---<---- (Close Data Set Send) S13,F7 S13,F8 (Close Data Set Ack) ---The GUI message below will be displayed while the file is being downloaded. File download in progress … Please standby! Note: • The xclient window will be temporarily locked during file transfer to prevent the operator from selecting any of the operational modes. • The above message will be removed upon completion of file download or if the reply message timer expires. If the timer expires then the host would have to send the remote command OS_FILE_DWNLD again to trigger the file download scenario. Upon completion of file download the above GUI message will be cleared and the required bonder OS version and the disk space specified in the PACKAGE.INF file will be verified. The host will be notified, using the existing Stream 6/ Function 11 (S6F11, Event Report Send) message, whether or not the bonder meets the requirement. The S6F11 message will be sent with collection event ID 8400 (CEID). There will be a status variable that will indicate the status of file transfer (See SVID 3048). Once the host is notified that the bonder meets the requirement for installing/upgrading software, the bonder should request the PACKAGE.TAR file. The download process will be similar to the scenario used when PACKAGE.INF file was downloaded. Upon completion of file download, the following GUI message will be displayed while files are being extracted from the PACKAGE.TAR file. Preparing files … Please standby! After the installation files have been extracted, the operator will be prompted with the following message dialog: Ready to install software version ATX1-8028-2-31.. Press OK to complete OS installation, CANCEL to abort. OK CANCEL - Pressing the OK button should reboot the bonder from a hard drive partition that has the files needed for OS installation. - Pressing the CANCEL button should not initiate OS installation. Instead, an internal flag will be set to indicate that host has downloaded files needed to install bonder software. This internal flag will be checked next time the Install item of the Software Options menu is selected. If the flag is set a dialog will be displayed to prompt the operator to either install the software from the floppy drive or from the hard drive. Install Current S/W version : ATX1-8028-2-30 1. From Floppy Drive 2. From Hard Drive (ATX1-8028-2-31) Done Page - 100 - of 321 Sep 18, 2020 Rev 4.1 Kulicke & Soffa™ SECS/GEM Interface for K&S Ball Bonders Bonder software version x-xx-x-472-series 4.18 TRACE: Example OS_FILE_DWNLD scenario Bonder must be IDLE. ------------------Communications INIT ------------------>>S>>> >>S>>> S2F41 "Host Command Send" >>S>>> S2F41R {L:2 {A "OS_FILE_DWNLD"} {L:0 } } <<<R<< <<<R<< S2F42 "Host Command Acknowledge" <<<R<< {2004-11-05 17:07:39} S2F42 {L:2 {B:1 0x04} {L:0}} <<<R<< <<<R<< S13F3 "Open Data Set Request" <<<R<< {2004-11-05 17:07:39} S13F3 {L:3 {U2:1 0} {A:11 PACKAGE_INF} {U4:1 0}} >>S>>> >>S>>> S13F4 "Open Data Set Data" >>S>>> S13F4 {L {U2 0} {A PACKAGE_INF} {B 0} {U2 0} {U4 1}} <<<R<< <<<R<< S13F5 "Read Data Set Request" <<<R<< {2004-11-05 17:07:39} S13F5 {L:2 {U2:1 0} {U4:1 2008683}} >>S>>> >>S>>> S13F6 "Read Data Set Data" >>S>>> S13F6 {L {U2 0} {B 0} {U4 0} {L {B 0x23 0x20 0x50 0x41 0x43 0x4b --------------- INTENTIONALLY TRUNCATED -----------------0x4f 0x4e 0x45 0x0d 0x0a 0x00}}} <<<R<< <<<R<< S13F5 "Read Data Set Request" <<<R<< {2004-11-05 17:07:40} S13F5 {L:2 {U2:1 0} {U4:1 2008683}} >>S>>> >>S>>> S13F6 "Read Data Set Data" >>S>>> S13F6 {L {U2 0} {B 8} {U4 0} {L}} <<<R<< <<<R<< S13F7 "Close Data Set Send" <<<R<< {2004-11-05 17:07:40} S13F7 {L:1 {U2:1 0}} >>S>>> >>S>>> S13F8 "Close Data Set Ack" >>S>>> S13F8 {L {U2 0} {B 0}} <<<R<< <<<R<< S13F3 "Open Data Set Request" <<<R<< {2004-11-05 17:07:40} S13F3 {L:3 {U2:1 0} {A:11 PACKAGE_TAR} {U4:1 0}} >>S>>> >>S>>> S13F4 "Open Data Set Data" >>S>>> S13F4 {L {U2 0} {A PACKAGE_TAR} {B 0} {U2 0} {U4 1}} <<<R<< <<<R<< S13F5 "Read Data Set Request" <<<R<< {2004-11-05 17:07:40} S13F5 {L:2 {U2:1 0} {U4:1 2016451}} >>S>>> >>S>>> S13F6 "Read Data Set Data" >>S>>> S13F6 {L {U2 0} {B 0} {U4 0} {L {B 0x49 0x4e 0x53 0x54 0x41 0x4c --------------- INTENTIONALLY TRUNCATED -----------------0xb7 0x86 0xf0 0x4d 0xa8 0x1c }}} <<<R<< <<<R<< S13F5 "Read Data Set Request" <<<R<< {2004-11-05 17:09:33} S13F5 {L:2 {U2:1 0} {U4:1 2016451}} >>S>>> >>S>>> S13F6 "Read Data Set Data" >>S>>> S13F6 {L {U2 0} {B 8} {U4 0} {L}} <<<R<< <<<R<< S13F7 "Close Data Set Send" <<<R<< {2004-11-05 17:09:34} S13F7 {L:1 {U2:1 0}} >>S>>> >>S>>> S13F8 "Close Data Set Ack" >>S>>> S13F8 {L {U2 0} {B 0}} END TRACE Page - 101 - of 321 Sep 18, 2020 Rev 4.1 Kulicke & Soffa™ SECS/GEM Interface for K&S Ball Bonders Bonder software version x-xx-x-472-series 4.19 Data Set Transfers The Data Set Transfers is used to upload/download non-PP files. Data Set Upload The data set upload scenario using the functions of Stream 13 is shown in the table below. COMMENT HOST EQUIPMENT COMMENT Open data set. S13,F3→ S13,F4 Open data set acknowledgment. Read data set. S13,F5→ S13,F6 Read data set acknowledgment. … … Close data set. S13,F7→ S13,F8 Close data set acknowledgment. The files that can be uploaded are as follows. DATA SET NAMES FOR UPLOAD Name Description BOND_PARM_ACCESS Password file for limiting the access to change bond parameters. BOND_PARM_LIMITS A tar’ed file contraining the bond parameters. Download this file can change bonder’s parameter opr/process limit. PBI_LOGLIST PBI log file list upload. If there are no PBI log files then Unknown Data Set name will be returned If there are PBI log files then a list of PBI log files will be returned. PBI_LOG PBI log file upload. MDP_FILE MDP file. PRIV_OP_ACCESS Op access password file. PRIV_SETTINGS File that contains the present privilege setting, e.g., user, system manager, etc. SERVICE_PWD_FILE This password file should only be downloaded to bonders with the ZTC option installed. USER_PWD_FILE User password file. BOND_POSITION_ACCESS Bond position file upload. Upon receiving this message, bonder will extract bond position to a temp file and transfer this file to the host. To execute Bond position data transfer, bonder should be in the IDLE. Or STANDBY mode, in order to extract bond position info from the current process program. INDIVIDUAL_LOG_FILE Backup an individual bonder log file by setting EC_Remote_Selected_LogFile. DEFECT_ID_FILE Defined cell grade. CUSTOMIZED_LOG Customized log. STRIP_MAP_LOG Strip map log file upload. PRIV_USER_DB Privilege user configuration file upload. INPUT_GOOD_CELL_GRADE Input cell grade upload. INPUT_UNKNOWN_CELL_GRADE User-defined cell grade upload. REAL_TIME_3RD_OPT_IMAGES Real time 3RD opt images file upload. Data Set Download The data set download scenario using the functions of Stream 13 is shown in the table below. Page - 102 - of 321 Sep 18, 2020 Rev 4.1 Kulicke & Soffa™ SECS/GEM Interface for K&S Ball Bonders Bonder software version x-xx-x-472-series COMMENT Send data set. HOST EQUIPMENT COMMENT S13,F1→ S13,F2 Send data set acknowledgment. S13,F3 Open data set. Open data set acknowledgment. S13,F4→ S13,F5 Read data set. Read data set acknowledgment. S13,F6→ … … S13,F7 Close data set. Close data set acknowledgment. S13,F8→ The files that can be downloaded are as follows. DATA SET NAMES FOR DOWNLOAD Name Description BOND_PARM_ACCESS Password file for limiting the access to change bond parameters. BOND_PARM_LIMITS A tar’ed file contraining the bond parameters. Download this file can change bonder’s parameter opr/process limit. MDP_FILE MDP file. PRIV_OP_ACCESS Op access password file. PRIV_SETTINGS File that contains the present privilege setting, e.g., user, system manager, etc. SERVICE_PWD_FILE This password file should only be downloaded to bonders with the ZTC option installed. USER_PWD_FILE User password file. DEFECT_ID_FILE Defined cell grade. PRIV_USER_DB Privilege user configuration file download. INPUT_GOOD_CELL_GRADE Input cell grade download. INPUT_UNKNOWN_CELL_GRADE User-defined cell grade download. See section10.5 Appendix for Data Set Transfer. 5. Message Transfer Protocols SEMI publishes two message transfer protocols for SECS-II message I/O: High-speed SECS Message Services (HSMS) and the SEMI Equipment Communications Standard 1 (SECS-I). NOTE: Interleaving messages is not supported. 5.1 High-speed SECS Message Services (HSMS) HSMS (SEMI E37) uses a stream sockets interface over a Transmission Control Protocol/Internet Protocol (TCP/IP) network to send and receive SECS-II messages. HSMS does not specify the physical network medium to be used; however, 10 Mb Ethernet is generally assumed. The equipment supports exactly one (1) HSMS port, in single-session (HSMS-SS) mode. The following HSMS protocol parameters are configurable at the equipment: Page - 103 - of 321 Sep 18, 2020 Rev 4.1 Kulicke & Soffa™ SECS/GEM Interface for K&S Ball Bonders Bonder software version x-xx-x-472-series Name Device ID T3 (Reply) Timeout T5 (Connect Separation) Timeout T6 (Control Transaction) Timeout T7 (Not Selected) Timeout T8 (Network Inter-character) Timeout Connect Mode HSMS PROTOCOL PARAMETERS Function Default Equipment identifier. 0 Specifies message reply timeout. 45 seconds Specifies amount of time between 10 successive attempts to connect to a seconds remote entity. Specifies length of time a control 5 seconds transaction may remain open before it is considered a communications failure. Time a TCP/IP connection can remain 10 in the NOT SELECTED state before it seconds is considered a communications failure. Maximum allowable time between 5 seconds successive bytes of an HSMS message. Specifies the logic the entity will use PASSIVE to establish an HSMS connection. Required in PASSIVE mode; defines the local connection entity. Local IP Address and Port Number Remote IP Required in ACTIVE mode; defines Address and the remote connection entity. Port Number Figure 56 - HSMS Protocol Parameters - Range 0-32767 1-120 seconds 1-240 seconds Resolution 1 1 second 1-240 seconds 1 second 1-240 seconds 1 second 1-120 seconds 1 second ACTIVE/ PASSIVE - - - - 1 second - The default protocol parameters are in effect only upon initial software installation. The configurable protocol parameters are stored in non-volatile memory and are restored each time the equipment is reset. Page - 104 - of 321 Sep 18, 2020 Rev 4.1 Kulicke & Soffa™ SECS/GEM Interface for K&S Ball Bonders Bonder software version x-xx-x-472-series 5.2 SEMI Equipment Communications Standard 1 (SECS-I) SECS-I (SEMI E4) uses an RS-232-C serial connection to send and receive SECS-II messages. The equipment supports exactly one (1) SECS-I port. The following SECS-I protocol parameters are configurable at the equipment: SECS-I PROTOCOL PARAMETERS Name Function Default Range Resolution Baud Rate Specifies serial line speed. 9600 300-19200 300, 600, 1200, 2400, 4800, 9600, 19200 Device ID Equipment identifier. 0 0-32767 1 T1 (InterDetects timeouts between received 0.5 second 0.1-10 0.1 second Character) characters. seconds Timeout T2 (Protocol) Detects lack of protocol response. 10 seconds 0.2-25 0.2 second Timeout seconds T3 (Reply) Specifies message reply timeout. 45 seconds 1-120 1 second Timeout seconds T4 (Inter-Block) Specifies inter-block receive 45 seconds 1-120 1 second Timeout timeout. seconds Retry Limit Specifies maximum block transmit 3 0-31 1 retries. Figure 57 - SECS-I Protocol Parameters The equipment is designated as the Master. The host should be configured as the Slave. Page - 105 - of 321 Sep 18, 2020 Rev 4.1 Kulicke & Soffa™ SECS/GEM Interface for K&S Ball Bonders Bonder software version x-xx-x-472-series 6. APPENDIX 0 - K&S Model Power Series Automatic Ball Bonder and K&S Model Gen-S Automatic Ball Bonder Shared Items 6.1 Introduction Appendix 0 contains tables of status variables, equipment constants, collection events, alarms, and data values which are shared by all models of K&S Model Power Series Automatic Ball Bonder and K&S Model Gen-S Automatic Ball Bonder. 6.2 K&S Model Power Series Automatic Ball Bonder and K&S Model Gen-S Automatic Ball Bonder Shared Status Variables The Status Variables (SVs) and associated Status Variable IDs (SVID) shared by K&S Model Power Series Automatic Ball Bonder and K&S Model Gen-S Automatic Ball Bonder are described in this section.Unless otherwise stated, the status variables listed below are not capable of being monitored by Limits Monitoring, as defined in SEMI E30, section 4.2.4. Page - 106 - of 321 Sep 18, 2020 Rev 4.1 Kulicke & Soffa™ SECS/GEM Interface for K&S Ball Bonders Bonder software version x-xx-x-472-series IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Status Variables SVID Name Type Description CommStopped BL[1] If the Communications State Model is disabled, then this status variable determines whether communications are enabled. (U2) 3000 FALSE = communications enabled TRUE = communications disabled 3001 CommState B[1] Current communications state. 0 = UNKNOWN 1 = COMMUNICATIONS DISABLED 2 = COMMUNICATIONS ENABLED/NOT COMMUNICATING 3 = Host initiated connection waiting for CR from host 4 = Host initiated connection waiting for TX from host 5 = Equipment initiated connection waiting for Host 6 = Wait delay 7 = Communicating 8-63 = Reserved 3002 ControlState B[1] Current control state. When reported, it is related to a control state transition. 0 = UNKNOWN 1 = OFFLINE/EQUIPMENT OFFLINE 2 = OFFLINE/ATTEMPTING TO GO ONLINE 3 = OFFLINE/HOST OFFLINE 4 = ONLINE/LOCAL 5 = ONLINE/REMOTE 6-63 = Reserved 3003 PreviousControlStat e B[1] Previous control state . When reported it is related to a control state transition. 3004 PPExecName A[81] The PPID of the process program which is currently selected. 3007 ProcessState U1[1] The current process state of the equipment. 0 = UNKNOWN 1 = PROCESSING NOT ACTIVE - all states other than those below 2 = AUTO RUN - In Auto mode and bonding 3 = ASSIST - In Auto mode and performing an assist 4 = PAUSED - In Auto mode and paused (Sequence Stop) 5 = WAITING - In Auto mode and not bonding (Backload MMM only) 6-63 = Reserved Page - 107 - of 321 Sep 18, 2020 Rev 4.1 Kulicke & Soffa™ SECS/GEM Interface for K&S Ball Bonders Bonder software version x-xx-x-472-series IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Status Variables SVID Name Type Description 3008 PreviousProcessSt ate U1[1] The previous process state of the equipment (see SVID3007 for values). 3009 AlarmsEnabled L[N] List of alarm IDs currently enabled for reporting. 3010 AlarmsSet L[N] List of alarm IDs currently enabled set. 3011 Clock A[17] The current value of the equipment time, format yyyymmddhhmmsscc. 3012 SpoolCountActual U4[1] Count of messages stored in spool. 3013 SpoolCountTotal U4[1] Count of total messages directed to the spool, regardless whether currently in the spool. 3014 SpoolFullTime A[17] Timestamp when the spool last became full, format yyyymmddhhmmsscc 3015 SpoolStartTime A[17] Timestamp from when spooling was last activated, format yyyymmddhhmmsscc 3016 SpoolStateGeneral B[1] Current major Spool State. (U2) 0 = UNKNOWN 1 = SPOOL INACTIVE 2 = SPOOL ACTIVE 3017 SpoolStateLoad B[1] The SPOOL LOAD component of SPOOL ACTIVE, set to UNKNOWN unless SpoolStateGeneral is SPOOL ACTIVE. 0 = UNKNOWN 3 = SPOOL INACTIVE 4 = SPOOL ACTIVE 3018 SpoolStateUnload B[1] The SPOOL UNLOAD component of SPOOL ACTIVE, set to UNKNOWN unless SpoolStateGeneral is SPOOL ACTIVE. 0 = UNKNOWN 5 = SPOOL NO OUTPUT 6 = SPOOL PURGE 7 = SPOOL XMIT 3019 EventsEnabled L[N] List of Collection Event Ids that are currently enabled for reporting. 3021 SV_START_COLU MN U2[1] Start column per index 3022 SV_END_COLUMN U2[1] End column per index Page - 108 - of 321 Sep 18, 2020 Rev 4.1 Kulicke & Soffa™ SECS/GEM Interface for K&S Ball Bonders Bonder software version x-xx-x-472-series IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Status Variables SVID Name Type Description Equipment Mode U1[1] Current equipment mode of operation (U2) 3030 0 = Idle 1 = Auto 2 = Manual 3 = Program 4 = Configure 5 = Calibration 6 = Utilities 7 = Diagnostic 8 = Sys Admin 9 = Host Initiated Transfer 10 = Equipment Initiated Transfer 11 = Standby (Motor Stop) 12 = Power Save 13 = Restoration 100 = Unintialized 3031 Light Tower State U2[1] Current light tower state. This status variable contains a 2 byte bit encoded data. The bit assignments are: 0 = Not used 1 = Not used 2,3 = Alarm 3 (see note 1) 4,5 = Alarm 2 (see note 1) 6,7 = Alarm 1 (see note 1) 8,9 = White Light (see note 1) 10,11 = Green Light (see note 1) 12,13 = Yellow Light (see note 1) 14,15 = Red Light (see note 1) Note 1: For all 2 bit codes: 00 = OFF 01 = ON 10 = BLINK OR PULSE 3032 Operator Data A A[81] Alpha/Numeric operator data. 3033 Operator Data B A[81] Alpha/Numeric operator data. 3034 Operator Data ID A[81] Alpha/Numeric operator data. Page - 109 - of 321 Sep 18, 2020 Rev 4.1 Kulicke & Soffa™ SECS/GEM Interface for K&S Ball Bonders Bonder software version x-xx-x-472-series IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Status Variables SVID Name Type Description InLoadPortState U2[1] Current transfer state of the preprocessing load port. (U2) 3035 (Backload MMM only) 0 = Port not ready for transfer (Port tray is full) 1 = Port ready for transfer 3036 InUnloadPortState U2[1] Current transfer state of the preprocessing unload port. (Backload MMM only) 0 = Port not ready for transfer (Port tray is empty) 1 = Port ready for transfer (Port tray contains magazine(s) ready to be picked up by the robot 0 = Port not ready for transfer (Port tray is empty) 1 = Port ready for transfer (Port tray contains magazine(s) ready to be picked up by the robot) 3037 OutLoadPortState U2[1] Current transfer state of the postprocessing load port. (Backload MMM only) 0 = Port not ready for transfer (Port tray is full) 1 = Port ready for transfer 3038 OutUnloadPortStat e U2[1] Current transfer state of the postprocessing unload port. port. (Backload MMM only) 0 = Port not ready for transfer (Port tray is empty) 1 = Port ready for transfer (Port tray contains magazine(s) ready to be picked up by the robot) 3039 SV_Clear_FA_Data _Dialog U1[1] Indicate which operator data dialog cleared all data Page - 110 - of 321 Sep 18, 2020 Rev 4.1 Kulicke & Soffa™ SECS/GEM Interface for K&S Ball Bonders Bonder software version x-xx-x-472-series IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Status Variables SVID Name Type Description SV_OpeModeCode U2[1] Indicates the current OPEN mode or activity in an OPE mode. (U2) 3045 1000 - Regular Production 2000 - Engineering 2010 - ENG/Process Engineering 2011 - ENG/Process Engineering/Evaluation Lot 2012 - ENG/Process Engineering/Sample Lot 2013 - ENG/Process Engineering/Setup-Conversion 2020 - ENG/Product Engineering 2021 - ENG/Product Engineering/Evaluation Lot 2022 - ENG/Product Engineering/Sample Lot 2023 - ENG/Product Engineering/Setup-Conversion 2030 - ENG/PEM 2031 - ENG/PEM/M/C Setup 2032 - ENG/PEM/M/C Conversion 2033 - ENG/PEM/M/C Upgrading 3000 - Schedule Activity 3010 - SA/Autonomous Maintenance 3011 - SA/Autonomous Maintenance/Cleaning/Inspection 3012 - SA/Autonomous Maintenance/Small Group Activity/Training 3020 - SA/Unmanned 3030 - SA/Planned Maintenance 3031 - SA/Planned Maintenance/Routine Maintenance/Modular PM 3032 - SA/Planned Maintenance/Major PM 3033 - SA/Planned Maintenance/Small Group Activity/Training 3040 - SA/Diagnostic Check 3050 - SA/Calibration 3060 - SA/Plant Shutdown(Reserved) 4000 - SCHDULE DOWNTIME 4010 – No Operator 4020 - No Material 5000 – UN SCHDULE DOWNTIME 6000 - Reserved 7000 – NON- SCHDULED TIME Page - 111 - of 321 Sep 18, 2020 Rev 4.1 Kulicke & Soffa™ SECS/GEM Interface for K&S Ball Bonders Bonder software version x-xx-x-472-series IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Status Variables SVID Name Type Description 3046 SV_OpeTechID A[41] The ID that is entered at the OPE Downtime mode dialog. 3047 SV_PrevToolUsage U4[1] The number of times the previous tool was used for bonding before it was replaced. This status variable is only updated when the Tool Changed event (CEID 8031) occurs. 3048 FileXfrStat I2[1] Status of file transfer in a scenario that uses stream 13 messages. (U2) 0 = Last data set download was successful 1 = Internal error. 2 = No partition exists. 3 = Unreliable partition. 4 = Invalid or corrupt INF file. 5 = Incompatible version. 6 = Invalid or corrupt TAR file. 95 = Invalid handle. 96 = File creation error. 97 = Unsupported record type. 98 = Host denied open data set request. 99 = Reply timer T3 expired. 3049 SV_BPCLeadSites L[N] Pair of lead sites where BPC failed 3050 SV_BPCLeadSiteR efSys A[40] Reference system where BPC failed 3051 USG Impedance F4[1] Machine tuned USG Low impedance as displayed in the USG Calibration dialog. 3052 SV_USGFrequency F4[1] Machine free air tuned Low USG frequency. 3053 BITS Status BL[1] Auto BITS status as displayed in the BITS Configurations or Auto Run Configuration dialog. ON = at least one wire has BITS enabled. OFF = no wire has BITS enabled. 3054 SoftwareVersion A[40] Current wire bonder software version. 3055 UpgradeSoftwareV ersion A[40] Upgrade version of the downloaded bonder software (i.e. TAR file) in /tmp0 partition that is to be installed into /sd0 partition. 3056 SV_WireCtrlStartDe viceName A[30] Device name of start control. (max 30 characters) 3057 SV_WireCtrlStopDe viceName A[30] Device name of stop control. (max 30 characters) Page - 112 - of 321 Sep 18, 2020 Rev 4.1 Kulicke & Soffa™ SECS/GEM Interface for K&S Ball Bonders Bonder software version x-xx-x-472-series IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Status Variables SVID Name Type Description 3058 SV_UsgTouchDow n U2[1] USG bond count. 3059 SV_PbiNumAvlBallI ds U1[1] PBI available ball IDs. 3060 SV_PbiNumAssgnd BallIds U1[1] Number of PBI assigned ball IDs. 3061 SV_PbiGetMeasure dBallSize U1[1] Nominal diameter for the given PBI Ball ID. 3062 SV_HFUSGFreque ncy F4[1] Machine free air tuned High USG frequency. 3063 SV_USGTransduce rType I2[1] USG transducer type 3064 SV_HFUSGImpeda nce F4[1] Machine tuned High USG frequency impedance as displayed in the USG Calibration dialog. 3065 SV_PeriodScanUS GImpedance F4[1] Period Scan USG Impedance (Note: If only enable high frequency USG on bonder configuration, it should used for HF USG Impedance. If enable both High/Low frequency, it should used for LF USG Impedance. 3066 SV_PeriodScanHF USGImpedance F4[1] Period Scan HF USG Impedance 3067 SV_Cover_Gas_Fai l_Skip_Mode U2[1] Cover Gas Fail Skip Mode 3068 SV_Bondsite_Air_B lower_State U1[1] Bondsite Air Blower Configuration. 3070 SV_DeviceCoordin ate A[20] Device coordination (column, row) 3071 SV_OriginLocation U1[1] Origin location 3072 SV_AlarmID U2[1] Corresponding alarm ID 3073 SV_AlarmDesc A[81] Alarm description for alarm ID 3081 SV_UserSV5 A[81] User SV5 on operator data entry#3 dialog 3082 SV_UserSV6 A[81] User SV6 on operator data entry#3 dialog 3083 SV_UserSV7 A[81] User SV7 on operator data entry#3 dialog 3084 SV_UserSV8 A[81] User SV8 on operator data entry#3 dialog 3085 SV_UserSV9 A[81] User SV9 on operator data entry#3 dialog 3086 SV_UserSV10 A[81] User SV10 on operator data entry#3 dialog 3087 SV_UserSV11 A[81] User SV11 on operator data entry#3 dialog 3088 SV_UserSV12 A[81] User SV12 on operator data entry#3 dialog 3089 SV_UserSV13 A[81] User SV13 on operator data entry#3 dialog (U2) 0=OFF/1=ON/2=Always ON Page - 113 - of 321 Sep 18, 2020 Rev 4.1 Kulicke & Soffa™ SECS/GEM Interface for K&S Ball Bonders Bonder software version x-xx-x-472-series IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Status Variables SVID Name Type Description 3090 SV_UserSV14 A[81] User SV14 on operator data entry#3 dialog 3091 UserSV1 A[81] User defined status variable 3092 UserSV2 A[81] User defined status variable 3093 UserSV3 A[81] User defined status variable 3094 UserSV4 A[81] User defined status variable 3096 SV_InhibitAuto I2[1] Indicates whether equipment is in “inhibit auto” state. (U2) 0 = Release inhibit auto state 1 = Inhibit auto state 3100 HitMode BL[1] Indicates whether equipment is in Host Initiated Transfer mode. FALSE = Equipment is NOT accepting Process Program transfers from host. TRUE = Equipment IS accepting Process Program transfers from host. 3101 UploadPPName A[81] Name of Process Program currently being transferred from equipment to host. Page - 114 - of 321 Sep 18, 2020 Rev 4.1 Kulicke & Soffa™ SECS/GEM Interface for K&S Ball Bonders Bonder software version x-xx-x-472-series 3102 UploadPPStatus B[1] Status of current process program transfer from equipment to host. 0 = Last upload was successful. 1 = Ready for upload. 2 = Equipment is requesting permission to upload a process program to host. 3 = N/A 4 = N/A 5 = N/A 6 = N/A 7 = N/A 8 = N/A 9 = Concatenating process program components into an uncompressed bundle. 10 = Compressing bundled components into a compressed bundle. 11 = Process program is ready to be sent to host. 12 = Waiting for host to request prepared process program bundle. 13 = Transmitting bundled program to host. 14 = N/A 15 = N/A 16 = Preparing Program 17 = Not Used 18 = Error code: memory allocation failure. 19 = Error code: Hard disk write failure. 20 = Error code: Internal failure. 21 = Error code: Illegal upload request. 22 = N/A 23 = Error code: Illegal PPID requested, 24 = N/A 25 = Error code: Operator-initiated upload request denied by host 26 = N/A 27 = N/A 28 = N/A 29 = Error code: Compression error 30 = Error code: Concatenation error 31 = Error code: Component of program missing Page - 115 - of 321 Sep 18, 2020 Rev 4.1 Kulicke & Soffa™ SECS/GEM Interface for K&S Ball Bonders Bonder software version x-xx-x-472-series IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Status Variables SVID Name Type Description (U2) 32 = Error code: Program not found 33 = N/A 34 = Error Code: Reply time T3 timeout. 3103 DownloadPPName A[81] Name of Process Program currently being transferred from host to equipment. Page - 116 - of 321 Sep 18, 2020 Rev 4.1 Kulicke & Soffa™ SECS/GEM Interface for K&S Ball Bonders Bonder software version x-xx-x-472-series 3104 Download PPStatus B[1] Status of current process program transfer from host to equipment. 0 = Last download was successful. 1 = Ready for download. 2 = Equipment is requesting permission to download a process program from host. 3 = Permission has been granted by host for a download. 4 = Receiving process program. 5 = Uncompressing downloaded process program. 6 = Separating downloaded process program components. 7 = Verifying downloaded process program. 8 = Saving downloaded process program to disk. 9 = N/A 10 = N/A 11 = N/A 12 = N/A 13 = N/A 14 = N/A 15 = Loading program to RAM 16 = N/A 17 = N/A 18 = Error code: memory allocation failure. 19 = Error code: Hard disk write failure. 20 = Error code: Internal failure. 21 = Error code: Illegal download request. 22 = Error code: Program exists and cannot be overwritten. 23 = Error code: Illegal PPID requested, 24 = N/A 25 = Error code: Operator-initiated download request denied by host. 26 = Error code: Decompression error 27 = Error code: Extraction error 28 = Error code: Verification error 29 = N/A 30 = N/A 31 = N/A 32 = N/A 33 = Error Code: Component overwrite not permitted. Page - 117 - of 321 Sep 18, 2020 Rev 4.1 Kulicke & Soffa™ SECS/GEM Interface for K&S Ball Bonders Bonder software version x-xx-x-472-series IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Status Variables SVID Name Type Description (U2) 34 = Error Code: Reply time - T3 timed out. 3105 PPEditDialog A[81] Name of the GUI dialog where a change was made to the process program in memory. 3106 PPSelectMode I4[1] Process program select mode 0 = by File Name 1 = by Long Name 3107 Bond Parameter Name L[N] Bond parameter names that were modified 3108 Bond Parameter Value L[N] Value of the parameter defined in the status variable Bond Parameter Name. 3109 Bond Parameter Wire Group U2[1] Wire group where the parameter changes were applied. 3110 Bond Parameter Change Apply Type U2[1] Scope of where parameter changes were applied: Wire, Group, or All. 3111 Bond Site Number L[N] List of bond sites that were modified. 3112 Bond Site X Coordinate L[N] X coordinates for the modified sites listed in the status variable bondsite Number. 3113 Bond Site Y Coordinate L[N] Y coordinates for the modified sites listed in the status variable bondsite Number. 3114 Instance Name A[40] Filename of the reference system with a bond location change. 3115 Reference System Filename A[40] Filename of the reference system with a bond location change. Page - 118 - of 321 Sep 18, 2020 Rev 4.1 Kulicke & Soffa™ SECS/GEM Interface for K&S Ball Bonders Bonder software version x-xx-x-472-series IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Status Variables SVID Name Type Description Completed PP Edit U2[1] Last edit performed on the process program in RAM. (U2) 3116 1 = Changed bond parameter 2 = Changed bond location 3 = Deleted bond site 4 = Resequenced wire 5 = Deleted wire 6 = Added wire 7 = Regrouped wire 8 = N/A 9 = Deleted reference system 10 = Moved reference system 11 = Rotated reference system 12 = Copied reference system 13 = Copied device 14 = Moved device 15 = Deleted device 16 = Resequenced device 17 = Rotated device 18 = Cleared process program in RAM 19 = Retaught pad 20 = Retaught lead 3117 SV_PP_ID A[80] PP that was Saved/Renamed/Deleted 3118 SV_PP_SAV_REN _DEL_STAT B[1] Flag for Saved/Renamed/Deleted 3119 SV_BondParmWire GrpList L[N] Bond Parm Wire Group List 3120 SV_LP_Init_PortID U1[1] Port id of init port report after machine reboot 1 - input loadport 2 - output unloadport 3 - input unload port 4 - output loadport Page - 119 - of 321 Sep 18, 2020 Rev 4.1 Kulicke & Soffa™ SECS/GEM Interface for K&S Ball Bonders Bonder software version x-xx-x-472-series IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Status Variables SVID Name Type Description SV_LP_Init_Transf er_State U1[1] Transfer state of init port report after machine reboot (U2) 3121 0 - OUT OF SERVICE 1 - TRARNSFER BLOCKED 2 - READY TO LOAD 3 - READY TO UNLOAD 3122 SV_LP_Init_Associ ation_State U1[1] Association state of init port report after machine reboot 0 - NOT ASSOCIATED 1 - ASSOCIATED 3123 SV_LP_Init_Reserv ation_State U1[1] Reservation state of init port report after machine reboot 0 - NOT RESERVED 1 - RESERVED 3124 SV_LP_TransferSta te_Change_State U1[1] Port transfer state of port transfer state changes 0 - OUT OF SERVICE 1 - TRARNSFER BLOCKED 2 - READY TO LOAD 3 - READY TO UNLOAD 3125 SV_LP_TransferSta te_Change_PortID U1[1] Port id of port transfer state changes 1 - input loadport 2 - output unloadport 3 - input unload port 4 - output loadport 3126 SV_LP_TransferSta te_Change_CarrierI D A[80] Carrier ID of port transfer state changes 3127 SV_AssociationStat e_Change_State U1[1] Port association state of port association state changes 0 - NOT ASSOCIATED 1 - ASSOCIATED 3128 SV_AssociationStat e_Change_PortID U1[1] Port id of port association state changes 1 - input loadport 2 - output unloadport 3 - input unload port 4 - output loadport Page - 120 - of 321 Sep 18, 2020 Rev 4.1 Kulicke & Soffa™ SECS/GEM Interface for K&S Ball Bonders Bonder software version x-xx-x-472-series IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Status Variables SVID Name Type Description SV_ReservationSta te_Change_State U1[1] Port reservation state of port reservation state changes (U2) 3129 0 - NOT RESERVED 1 - RESERVED 3130 SV_ReservationSta te_Change_PortID U1[1] Port id of port reservation state changes 1 - input loadport 2 - output unloadport 3 - input unload port 4 - output loadport 3131 SV_CarrierAccessi ngStatus_Status U1[1] Status of carrier accessing status changes 0 - NOT ACCESSED 1 - IN ACCESS 2 - CARRIER COMPLETE 3 - CARRIER STOPPED 3132 SV_CarrierAccessi ngStatus_CarrierID A[80] Carrier ID that carrier accessing status changes 3133 SV_CarrierAccessi ngStatus_LocationI D A[80] Location ID that carrier accessing status changes Note: Bonder does verification at buffer, so location id is provided. This differs from Micron’s provided workflow. This item is not required by semi E87 Text for location id, scope as below. { P1, P2, Buffer1, Buffer2, P3, P4, } 3134 SV_CarrierIDStatus _Status U1[1] Status of carrier ID status changes 0 - ID NOT READ 1 - ID WAITING FOR HOST 2 - ID VERIFICATION OK 3 - ID VERIFICATION FAILED 3135 SV_CarrierIDStatus _CarrierID A[80] Carrier ID of carrier ID status changes Page - 121 - of 321 Sep 18, 2020 Rev 4.1 Kulicke & Soffa™ SECS/GEM Interface for K&S Ball Bonders Bonder software version x-xx-x-472-series IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Status Variables SVID Name Type Description SV_CarrierIDStatus _LocationID A[80] Location ID of carrier ID status changes (U2) 3136 Note: Bonder does verification at buffer, so location id is provided. This differs from semi E87 standard Text for location id, scope as below. { P1, P2, Buffer1, Buffer2, P3, P4, } max 80 characters 3137 SV_SlotMapStatus _Status U1[1] SlotMap Status. Current state of slot map status. 0 - SLOT MAP NOT READ 1 - SLOT MAP WAITING FOR HOST 2 - SLOT MAP VERIFICATION OK 3 - SLOT MAP VERIFICATION FAILED 3138 SV_SlotMapStatus _CarrierID A[80] Carried ID that slotmap status changes 3139 SV_SlotMapStatus _LocationID A[80] Location ID that slotmap status changes Text for location id, scope as below. { P1, P2, Buffer1, Buffer2, P3, P4, } max 80 characters 3140 SV_AccessMode_ Mode U1[1] Current access mode 0 - Manual 1 - Auto Page - 122 - of 321 Sep 18, 2020 Rev 4.1 Kulicke & Soffa™ SECS/GEM Interface for K&S Ball Bonders Bonder software version x-xx-x-472-series IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Status Variables SVID Name Type Description SV_AccessMode_P ortID U1[1] Port ID of access mode changes (U2) 3141 1 - input loadport 2 - output unloadport 3 - input unload port 4 - output loadport 3142 SV_CarrierCreated _CarrierID A[80] CarrierID of carrier created 3143 SV_CarrierCreated _PortID U1[1] Port ID of carrier created 1 - input loadport 2 - output unloadport 3 - input unload port 4 - output loadport 3144 SV_CarrierLoc_Ch ange_CarrierID A[80] Carrier ID that carrier location changes 3145 SV_CarrierLoc_Ch ange_LocationID A[80] Location ID that carrier location changes Text for location id, scope as below. { P1, P2, Buffer1, Buffer2, P3, P4, } max 80 characters 3146 SV_PortOccupied_ PortID U1[1] Port ID indicates which port occupied 1 - input loadport 2 - output unloadport 3 - input unload port 4 - output loadport Page - 123 - of 321 Sep 18, 2020 Rev 4.1 Kulicke & Soffa™ SECS/GEM Interface for K&S Ball Bonders Bonder software version x-xx-x-472-series IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Status Variables SVID Name Type Description SV_PortOccupied_ TransferState U1[1] Transfer State of port that occupied (U2) 3147 0 - OUT OF SERVICE 1 - TRARNSFER BLOCKED 2 - READY TO LOAD 3 - READY TO UNLOAD 3148 SV_PortOccupied_ AssociationState U1[1] Association state of port that occupied 0 - NOT ASSOCIATED 1 - ASSOCIATED 3149 SV_PortOccupied_ ReservationState U1[1] Reservation state of port that occupied 0 - NOT RESERVED 1 - RESERVED 3150 SV_PortEmptyPortI D U1[1] Port ID indicates which load port is empty 1 - input loadport 2 - output unloadport 3 - input unload port 4 - output loadport 3151 SV_CJ_Status_Cha nge_JobID A[80] Control Job ID that status changes 3152 SV_CJ_Status_Cha nge_Status U1[1] Control Job status that status changes.Scope as below 0 - QUEUED 1 - SELECTED 2 - WAITING FOR START 3 - EXECUTING 4 – PAUSED 5 – COMPLETED 3153 SV_PJ_Status_Cha nge_JobID A[80] Process Job ID that status changes Page - 124 - of 321 Sep 18, 2020 Rev 4.1 Kulicke & Soffa™ SECS/GEM Interface for K&S Ball Bonders Bonder software version x-xx-x-472-series IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Status Variables SVID Name Type Description SV_PJ_Status_Cha nge_Status U1[1] Process Job status that status changes.Scope as below (U2) 3154 0 - QUEUED/POOLED 1 - SETTING UP 2 - WAITING FOR START 3 - PROCESSING 4 – PROCESS COMPLETE 5 – (Reserved) 6 - PAUSING 7 - PAUSED 8 - STOPPING 9 - ABORTING 10 - STOPPED 11 - ABORTED 3155 SV_PJ_Status_Cha nge_RecipeID A[80] RecipeID of process job that status changes 3156 SV_CJ_QueueSpa ce U1[1] How many control jobs can be newly created. Note: Only one control job can be queued. If the queued control job status is changed to selected, host can queue the next control job How many control jobs can be queued 3157 SV_PJ_Queue_Sp ace U1[1] How many process jobs can be newly created. Note: Only one process job can be queued. If the queued process job status is changed to setting up, host can queue the next control job How many process jobs can be queued. 3158 SV_PortID U1[1] Port ID of related state changes 1 - input loadport 2 - output unloadport 3 - input unload port 4 - output loadport 3159 SV_CarrierID A[80] Carrier ID of related state changes 3160 SV_LocationID A[80] Location ID of related state changes 3161 SV_AccessMode_P 1 U1[1] Access mode of P1 0 - Manual 1 - Auto Page - 125 - of 321 Sep 18, 2020 Rev 4.1 Kulicke & Soffa™ SECS/GEM Interface for K&S Ball Bonders Bonder software version x-xx-x-472-series IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Status Variables SVID Name Type Description SV_AssociationStat e_P1 U1[1] Association state of P1 (U2) 3162 0 - NOT ASSOCIATED 1 - ASSOCIATED 3163 SV_ReservationSta te_P1 U1[1] Reservation state of P1 0 - NOT RESERVED 1 - RESERVED 3164 SV_TransferState_ P1 U1[1] Transfer state of P1 0 - OUT OF SERVICE 1 - TRARNSFER BLOCKED 2 - READY TO LOAD 3 - READY TO UNLOAD 3165 SV_AccessMode_P 2 U1[1] Access mode of P2 0 - Manual 1 - Auto 3166 SV_AssociationStat e_P2 U1[1] Association state of P2 0 - NOT ASSOCIATED 1 - ASSOCIATED 3167 SV_ReservationSta te_P2 U1[1] Reservation state of P2 0 - NOT RESERVED 1 - RESERVED 3168 SV_TransferState_ P2 U1[1] Transfer state of P2 0 - OUT OF SERVICE 1 - TRARNSFER BLOCKED 2 - READY TO LOAD 3 - READY TO UNLOAD 3169 SV_AccessMode_P 3 U1[1] Access mode of P3 0 - Manual 1 - Auto 3170 SV_AssociationStat e_P3 U1[1] Association state of P3 0 - NOT ASSOCIATED 1 - ASSOCIATED 3171 SV_ReservationSta te_P3 U1[1] Reservation state of P3 0 - NOT RESERVED 1 - RESERVED Page - 126 - of 321 Sep 18, 2020 Rev 4.1 Kulicke & Soffa™ SECS/GEM Interface for K&S Ball Bonders Bonder software version x-xx-x-472-series IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Status Variables SVID Name Type Description SV_TransferState_ P3 U1[1] Transfer state of P3 (U2) 3172 0 - OUT OF SERVICE 1 - TRARNSFER BLOCKED 2 - READY TO LOAD 3 - READY TO UNLOAD 3173 SV_AccessMode_P 4 U1[1] Access mode of P4 0 - Manual 1 - Auto 3174 SV_AssociationStat e_P4 U1[1] Association state of P4 0 - NOT ASSOCIATED 1 - ASSOCIATED 3175 SV_ReservationSta te_P4 U1[1] Reservation state of P4 0 - NOT RESERVED 1 - RESERVED 3176 SV_TransferState_ P4 U1[1] Transfer state of P4 0 - OUT OF SERVICE 1 - TRARNSFER BLOCKED 2 - READY TO LOAD 3 - READY TO UNLOAD 3177 SV_CarrierLocation Matrix L[N] A list all the carriers at/in the equipment. Both internal to the equipment, and on equipment load ports. 3178 SV_SubstLocID A[80] Identifier of substrate location 3179 SV_SubSource A[83] Substrate comes from which slot of which input carrier 3180 SV_SubDestination A[83] Substrate is ejected to which slot of which output carrier 3181 SV_SlotMapStatus _SlotMap L[N] Slot Map that is waiting for slot map verification 3182 SV_SlotMapStatus _Reason U1[1] The reason of Slot Map waiting for slot map verification 0=verification needed 1=verification by equipment unsuccessful 2=read fail 3=improper substrate position 3183 SV_SubstLocChg_ SubID A[80] Substrate ID of substrate location changes 3190 SV_RAMPP_LastS avedTime A[15] Last saved time of the pp in ram Page - 127 - of 321 Sep 18, 2020 Rev 4.1 Kulicke & Soffa™ SECS/GEM Interface for K&S Ball Bonders Bonder software version x-xx-x-472-series IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Status Variables SVID Name Type Description 3191 SV_DISKPP_LastS avedTime A[15] Last saved time of the pp in disk 3200 Zone1 Temperature I4[1] Temperature in degrees Celsius at Pre-Bond. This SV is capable of being monitored by Limits Monitoring, as defined in SEMI E30, section 4.2.4 3201 Zone2 Temperature I4[1] Temperature in degrees Celsius at Bond. This SV is capable of being monitored by Limits Monitoring, as defined in SEMI E30, section 4.2.4 3202 Zone3 Temperature I4[1] Temperature in degrees Celsius at Post-Bond. This SV is capable of being monitored by Limits Monitoring, as defined in SEMI E30, section 4.2.4 3203 SV_Zone1_Temper ature_offset I4[1] Pre_Bond temperature offset 3204 SV_Zone2_Temper ature_offset I4[1] In_Bond temperature offset 3205 SV_Zone3_Temper ature_offset I4[1] Post_Bond temperature offset 3206 SV_Zone1_Temper ature_State U2[1] Temperature On/Off 3207 SV_Zone2_Temper ature_State U2[1] Temperature On/Off 3208 SV_Zone3_Temper ature_State U2[1] Temperature On/Off 3209 SV_Zone1_Temper ature_SetPoint I4[1] Temperature Setpoint 3210 SV_Zone2_Temper ature_SetPoint I4[1] Temperature Setpoint 3211 SV_Zone3_Temper ature_SetPoint I4[1] Temperature Setpoint 3212 SV_Zone1_Temper ature_Tolerance I4[1] Temperature Tolerance 3213 SV_Zone2_Temper ature_Tolerance I4[1] Temperature Tolerance 3214 SV_Zone3_Temper ature_Tolerance I4[1] Temperature Tolerance 3220 SV_OS_VERSION A[40] OS Software version 3221 SV_OS_SERVICE_ PACK A[40] OS software service pack 3222 SV_CHGOVER_PA RTS_PER_CARRI ER U1[1] Parts per carrier for changeover (U2) Page - 128 - of 321 Sep 18, 2020 Rev 4.1 Kulicke & Soffa™ SECS/GEM Interface for K&S Ball Bonders Bonder software version x-xx-x-472-series IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Status Variables SVID Name Type Description 3223 SV_CHGOVER_PP ID A[81] Program name for changeover 3224 SV_CHGOVER_TO OL_FAMILY A[81] Tool family for changeover 3225 SV_CHGOVER_WI REPARTNO A[81] Wire part no. for changeover 3226 SV_CHGOVER_IN _PROGRESS BL[1] Whether changeover is in process 3227 SV_PART_ID_IN_P ROCESS A[81] Which part id is in process 3228 SV_CURRENT_IN STALLED_TOOL_F AMILY A[81] Current installed tool family 3229 SV_CURRENT_IN STALLED_WIRE_P ART_NO A[81] Current installed wire part no. 3230 SV_TO_BE_INSTA LLED_TOOL_ID A[81] Tool ID to be installed 3231 SV_TO_BE_INSTA LLED_TOOL_FAMI LY A[81] Tool family to be installed 3232 SV_TO_BE_INSTA LLED_TOOL_COU NTER U4[1] Tool counter to be installed 3233 SV_TO_BE_INSTA LLED_WIRE_ID A[81] Wire id to be installed 3234 SV_TO_BE_INSTA LLED_WIRE_PART _NO A[81] Wire part no. to be installed 3235 SV_CURRENT_IN STALLED_WIRE_I D A[81] Wire ID of current installed wire 3236 SV_PREV_INSTAL LED_WIRE_ID A[81] Wire ID of previous installed wire 3237 SV_CURRENT_IN STALLED_TOOL_I D A[81] Tool ID of current installed tool 3239 SV_MACHINE_BO OTUP_TIME A[21] Machine Boot Up Time 3240 SV_P1_LotId A[81] Text of LotID of mag on input load tray 3241 SV_P2_LotId A[81] Text of LotID of mag on output unload tray (U2) Page - 129 - of 321 Sep 18, 2020 Rev 4.1 Kulicke & Soffa™ SECS/GEM Interface for K&S Ball Bonders Bonder software version x-xx-x-472-series IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Status Variables SVID Name Type Description 3242 SV_P3_LotId A[81] Text of LotID of mag on input unload tray 3243 SV_P4_LotId A[81] Text of LotID of mag on output load tray 3244 SV_Buffer1_LotId A[81] Text of LotID of mag on input processing unit 3245 SV_Buffer2_LotId A[81] Text of LotID of mag on output processing unit 3246 SV_PIO_Continue_ Bit BL[1] The status of PIO continue bit 3247 SV_Carrier_Push_ No U2[1] Total number of carriers transferred from the loader magazine 3248 SV_Latest_Alarm_ Report U2[1] Latest event code which pop up 3249 SV_Latest_Alarm_ Cleared U2[1] Latest event code which cleared 3250 SV_Current_Alarm _Count U2[1] Current event count which pop up 3300 Input LF Count U2[1] Number of lead frames removed from magazine in input side gripper. 3301 Output LF Count U2[1] Number of lead frames inserted into magazine in output side gripper. 3302 Devices Processed U4[1] Count of devices successfully processed since the equipment was powered on, or since the host last reset production counters via RESET_PROD_COUNTERS remote command. 3303 Devices Skipped U4[1] Count of devices skipped since the equipment was powered on, or since the host last reset production counters via RESET_PROD_COUNTERS remote command. 3304 Input Bar Code A[81] Bar Code of magazine in input side gripper. Valid if Input Scan Status SV = 0 or 1. 3305 Output Bar Code A[81] Bar Code of magazine in output side gripper. Valid if Output Scan Status SV = 0 or 1. 3306 Material Source Bar Code A[81] Bar Code number of the source magazine. Like the Input Bar Code SV, but qualified as having been accepted by the EQC. 3307 Input Scan Status B[1] Status of bar code scan of magazine in input side gripper. (U2) 0 = OK 1 = bar code keyed in manually 2 = scan failed 3308 Output Scan Status B[1] Status of bar code scan of magazine in output side gripper. 0 = OK 1 = bar code keyed in manually 2 = scan failed Page - 130 - of 321 Sep 18, 2020 Rev 4.1 Kulicke & Soffa™ SECS/GEM Interface for K&S Ball Bonders Bonder software version x-xx-x-472-series IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Status Variables SVID Name Type Description SV_MagEjectOpt BL[1] Magazine Eject Option (U2) 3309 Ported to Central by FEA1264 3310 SV_WHL_Status BL[1] The status indicates whether whl has L/F or not 3319 SV_2D_CODE A[81] 2D Code scanned by 2D reader. 3320 SV_STRIP_ID A[81] ID of Strip Map, which uniquely identifies the strip map. 3321 SV_STRIP_ROW U4[1] The number of rows of Strip Map (Download from host) 3322 SV_STRIP_COLU MN U4[1] The number of columns of Strip Map (Download from host) 3323 SV_STRIP_ORIGI NLOCATION U1[1] Coordinate system of Strip Map to address devices. 0 = N/A 1 = Upper right (UR) - top side, 2 = Upper left (UL) - top side, 3 = Lower left (LL) - top side, 4 = Lower right (LR) - top side, 6 = Upper right (UR) - bottom side, 7 = Upper left (UL) - bottom side, 8 = Lower left (LL) - bottom side, 9 = Lower right (LR) - bottom side. 10 = N/A 3324 SV_STRIP_CELLS TATUS L[N] A list of values indicating the value of each unit on a strip. 0 = Good, 1 = Unknown, 2 = Defect 3325 SV_STRIP_LOTID A[30] Production lot identifier this data. 3326 SV_STRIP_TRANS ACTION I2[1] Strip transaction 3327 SV_STRIP_CELLG RADE L[N] A list of values indicating the classification of each unit on a strip. Custom in Strip Map configuration dialog. 3328 SV_UPLOAD_MAP _STRIP_ID A[81] Strip ID for uploaded strip map data 3329 SV_STRIP_CELL_ COORDINATE A[20] Strip cell coordinate (Format: Col-Row) 3330 SV_EXPECTED_S TRIP_ROW U4[1] Expected strip row number based on process program 3331 SV_EXPECTED_S TRIP_COL U4[1] Expected strip column number based on process program Page - 131 - of 321 Sep 18, 2020 Rev 4.1 Kulicke & Soffa™ SECS/GEM Interface for K&S Ball Bonders Bonder software version x-xx-x-472-series IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Status Variables SVID Name Type Description 3332 SV_STRIP_WIRE_ USAGE F4[1] Wire usage of current processed strip. Unit is Feet. It is guaranteed to be updated when strip map ready for upload event (CEID 8336) occurs. 3350 SV_SAFETY_KIT_ STATUS BL[1] Safety sensor status 3360 SV_BFC_Scale_Fa ctor F4[1] Bond Force Scale Factor 3361 SV_EFO_Cal_Heig ht F4[1] EFO Calibration Height Value 3362 SV_RealTime_3rd_ Opt_Option U4[1] Real Time 3rd Option 3363 SV_DummyState U1[1] Dummy mode State: 0 = Normal; 1=Dummy;2=Local (U2) 1 = Dummy Dummy mode state 0 = Normal 1 = Dummy2 = Local 3364 SV_Realtime_FAB_ Flow_Rate F4[1] Real time FAB gas flow rate 3365 SV_Realtime_Bond _Flow_Rate F4[1] Real time bond gas flow rate 3366 SV_Realtime_Clam p_Flow_Rate F4[1] Real time clamp gas flow rate 3367 SV_LHM_MEASUR ED_WIRE_LOOP_I D L[N] Loop ID of each measured wire 3368 SV_LHM_DEVICE_ RESULT U1[1] Measurement result of reported device (0 – Within Limit 1 – Exceeds Error Limit 2 – Exceeds Warning Limit) 3369 SV_LHM_MEASUR ED_WIRE_ID L[N] Measured wire IDs 3370 SV_LHM_MAX_LO OP_HEIGHT_SAM PLE_QTY U4[1] Number of maximum loop height samples 3371 SV_LHM_MAX_LO OP_HEIGHT_VAL UES L[N] Maximum loop height of each measured wire 3372 SV_LHM_EDGE_H EIGHT_SAMPLE_ QTY U4[1] Number of edge height samples Page - 132 - of 321 Sep 18, 2020 Rev 4.1 Kulicke & Soffa™ SECS/GEM Interface for K&S Ball Bonders Bonder software version x-xx-x-472-series IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Status Variables SVID Name Type Description 3373 SV_LHM_EDGE_H EIGHT_VALUES L[N] Edge height of each measured wire 3374 SV_LHM_MAX_LO OP_HEIGHT_LEA RNED_VALUES L[N] Learned maximum loop height of each measured wire 3375 SV_LHM_EDGE_C LEARANCE_LEAR NED_VALUES L[N] Learned edge height of each measured wire 3376 SV_LHM_LOOP_H EIGHT_WARN_UP PER_LIMITS L[N] Upper warning limits (loop height) for each measured wire 3377 SV_LHM_LOOP_H EIGHT_WARN_LO WER_LIMITS L[N] Lower warning limits (loop height) for each measured wire 3378 SV_LHM_LOOP_H EIGHT_ERROR_U PPER_LIMITS L[N] Upper error limits (loop height) for each measured wire 3379 SV_LHM_LOOP_H EIGHT_ERROR_L OWER_LIMITS L[N] Lower error limits (loop height) for each measured wire 3380 SV_LHM_EDGE_C LEARANCE_WAR N_UPPER_LIMITS L[N] Upper warning limits (edge height) for each measured wire 3381 SV_LHM_EDGE_C LEARANCE_WAR N_LOWER_LIMITS L[N] Lower warning limits (edge height) for each measured wire 3382 SV_LHM_EDGE_C LEARANCE_ERRO R_UPPER_LIMITS L[N] Upper error limits (edge height) for each measured wire 3383 SV_LHM_EDGE_C LEARANCE_ERRO R_LOWER_LIMITS L[N] Lower error limits (edge height) for each measured wire 3384 SV_LHM_MAX_LO OP_HEIGHT_MEA S_CODE A[20] Code for maximum loop height measurement 3385 SV_LHM_EDGE_H EIGHT_MEAS_CO DE A[20] Code for edge height measurement 3386 SV_LHM_LOOP_H EIGHT_ASSIGNED _LOOP_ID L[N] Loop IDs that are assigned to loop height measurement (U2) Page - 133 - of 321 Sep 18, 2020 Rev 4.1 Kulicke & Soffa™ SECS/GEM Interface for K&S Ball Bonders Bonder software version x-xx-x-472-series IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Status Variables SVID Name Type Description 3387 SV_LHM_LOOP_H EIGHT_ASSIGNED _LOOP_ID_WARN _UPPER_LIMITS L[N] Upper warning limits (loop height) correspond to SV_LHM_LOOP_HEIGHT_ASSIGNED_LOOP_ID 3388 SV_LHM_LOOP_H EIGHT_ASSIGNED _LOOP_ID_WARN _LOWER_LIMITS L[N] Lower warning limits (loop height) correspond to SV_LHM_LOOP_HEIGHT_ASSIGNED_LOOP_ID 3389 SV_LHM_LOOP_H EIGHT_ASSIGNED _LOOP_ID_ERRO R_UPPER_LIMITS L[N] Upper error limits (loop height) correspond to SV_LHM_LOOP_HEIGHT_ASSIGNED_LOOP_ID 3390 SV_LHM_LOOP_H EIGHT_ASSIGNED _LOOP_ID_ERRO R_LOWER_LIMITS L[N] Lower error limits (loop height) correspond to SV_LHM_LOOP_HEIGHT_ASSIGNED_LOOP_ID 3391 SV_LHM_EDGE_H EIGHT_ASSIGNED _LOOP_ID L[N] Loop IDs that are assigned to edge height measurement 3392 SV_LHM_EDGE_H EIGHT_ASSIGNED _LOOP_ID_WARN _UPPER_LIMITS L[N] Upper warning limits (edge height) correspond to SV_LHM_EDGE_HEIGHT_ASSIGNED_LOOP_ID 3393 SV_LHM_EDGE_H EIGHT_ASSIGNED _LOOP_ID_WARN _LOWER_LIMITS L[N] Lower warning limits (edge height) correspond to SV_LHM_EDGE_HEIGHT_ASSIGNED_LOOP_ID 3394 SV_LHM_EDGE_H EIGHT_ASSIGNED _LOOP_ID_ERRO R_UPPER_LIMITS L[N] Upper error limits (edge height) correspond to SV_LHM_EDGE_HEIGHT_ASSIGNED_LOOP_ID 3395 SV_LHM_EDGE_H EIGHT_ASSIGNED _LOOP_ID_ERRO R_LOWER_LIMITS L[N] Lower error limits (edge height) correspond to SV_LHM_EDGE_HEIGHT_ASSIGNED_LOOP_ID 3396 SV_LHM_HOST_V ALIDATION_STAT E U1[1] Auto Loop Height Measurement Host Validation State 3401 SV_Osc_Current_F actor F4[1] USG current factor in Osc / Amp Results menu 3402 SV_Person_Curren t_Factor F4[1] USG current factor in Personality Values 3403 SV_MDP_ModifyNa me L[N] This SV is for generic MDP Parameter change report (U2) Page - 134 - of 321 Sep 18, 2020 Rev 4.1 Kulicke & Soffa™ SECS/GEM Interface for K&S Ball Bonders Bonder software version x-xx-x-472-series IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Status Variables SVID Name Type Description 3404 SV_MDP_ModifyVa lue L[N] This SV is for generic MDP Parameter change report 3405 SV_HF_Osc_Curre nt_Factor F4[1] High Frequency USG current factor in Osc / Amp Results menu 3406 SV_HF_Person_Cu rrent_Factor F4[1] High Frequency USG current factor in Personality Values 3417 SV_RCMD_InMag I2[1] Input magazine is accepted or rejected remotely by host. (0 = Accepted, 1 = Rejected) 3418 SV_RMCD_OutMa g I2[1] Output magazine is accepted or rejected remotely by host. (0 = Accepted, 1 = Rejected) 3420 SV_LatestErrorSub Coordinate A[10] Substrate Col/Row information of latest error 3421 SV_LatestErrorInst ance A[40] Instance Name of latest error 3476 SV_ToolUsageHour sInUse U4[1] Tool has been used in hours 3477 SV_ToolChanged A[18] Time that tool changed 3478 SV_CAP_CLEAN_ COUNT U2[1] Count for cap clean has been done 3479 SV_TapeUsedTouc hDown U4[1] Count for tap touch down on tap 3480 SV_TapeRemainTo uchDown U4[1] Touch down that not used 3481 SV_WireUsed F4[1] Wire length that has been used 3482 SV_TimeRemaining F4[1] Time remain 3500 Wires Bonded U4[1] PM SV: Number of wires bonded during Engineering Time and Productive Time. 3501 Devices Bonded U4[1] PM SV: Number of devices bonded. 3502 Standby Time F4[1] PM SV: Time bonder was up, but was in Standby Mode (see SEMI E-10). [Hrs.] 3503 Productive Time F4[1] PM SV: Time bonder was up and executing Auto Mode (see SEMI E-10). [Hrs.] 3504 Engineering Time F4[1] PM SV: Sum of Standby Time and Productive Time. [Hrs.] 3505 Bonder Utilization F4[1] PM SV: Percent of Productive Time during total time (PM_StopTime - PM_StartTime). 3506 Net MTBAp F4[1] PM SV: Mean (productive) Time Between Assists. [Hrs.] 3507 MCBA F4[1] PM SV: Mean Cycles (devices processed) Between Assists. 3508 Gross UPH F4[1] PM SV: Units Per Hour in any mode since PM_StartTime. (U2) Page - 135 - of 321 Sep 18, 2020 Rev 4.1 Kulicke & Soffa™ SECS/GEM Interface for K&S Ball Bonders Bonder software version x-xx-x-472-series IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Status Variables SVID Name Type Description 3509 Net UPH F4[1] PM SV: Units Per Hour in auto mode since PM_StartTime. 3510 EFO U4[1] PM SV: Number of EFO Open exceptions. 3511 Devices Skipped U4[1] PM SV: Number of devices skipped, owing to process exceptions. 3512 MHS Interrupts U4[1] PM SV: Number of MHS related errors, including following categories and errors. (U2) • WHL: MHSEyeFailure; InjectorPuller; BondingSite; IndexerTucker; JamDetect; Sensor; • Mag Handler: InputMagOperation; InputMagSensor; OutputMagOperation; OutputMagSensor; • Material: NoInputMaterial; /* Input Mag. Empty */ OutputMagFull; 3513 NSOP U4[1] PM SV: Number of No Stick On Pad or broken wire exceptions. 3514 NSOL U4[1] PM SV: Number of No Stick On Lead or bad tail exceptions. 3515 Short Tails U4[1] PM SV: Number of short tail exceptions. 3516 Assists U4[1] PM SV: Number of events requiring assists. 3517 MTBFp F4[1] PM SV: Mean Time Between Failures 3518 MCBF F4[1] PM SV: Mean Cycles Between Failures 3519 Net Failures U4[1] PM SV: Total failures due to machine out-of-spec. 3520 Tool Usage U4[1] Non-PM SV: The number of times the tool has been used for bonding. 3521 Wire Remaining F4[1] Non-PM SV: The wire length remaining in the spool. 3522 Lot Device Bonded U4[1] Non-PM SV: Number of devices bonded in the current lot. 3523 Temperature Errors U4[1] PM SV: Number of temperature errors 3524 Missing Wire Detect U4[1] PM SV: Missing wire error count (For wedge) Page - 136 - of 321 Sep 18, 2020 Rev 4.1 Kulicke & Soffa™ SECS/GEM Interface for K&S Ball Bonders Bonder software version x-xx-x-472-series IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Status Variables SVID Name Type Description 3525 Device Eye Failures U4[1] PM SV: Device eye failure count. 3526 VLL Find Failures U4[1] PM SV: Number of VLL find failures. 3527 Line Tolerance Failures U4[1] PM SV: Number of Line Tolerance failures. 3528 No Input Materials U4[1] PM SV: Empty input magazine tray error count. 3529 Output Mag Full U4[1] PM SV: Full output magazine tray error count. 3530 Wire Feed Error U4[1] PM SV: Number of Wire feed failures. 3531 Air Supply Low U4[1] PM SV: Low air pressure error count 3532 MHS Eye Failures U4[1] PM SV: Number of MHS Eye failures. 3533 Injector Puller U4[1] PM SV: Number of Injector puller failures. 3534 Bonding Site U4[1] PM SV: Number of Bonding site failures. 3535 Indexer Tucker U4[1] PM SV: Number of Indexer Tucker failures. 3536 Jam Detect U4[1] PM SV: Number of workholder jams. 3537 Workholder Sensor U4[1] PM SV: Number of Workholder sensor failures. 3538 Input Mag Operation U4[1] PM SV: Number of Input magazine operation failures. 3539 Input Mag Sensor U4[1] PM SV: Number of Input magazine sensor failures. 3540 Output Mag Operation U4[1] PM SV: Number of Output magazine operation failures. 3541 Output Mag Sensor U4[1] PM SV: Number of Output magazine sensor failures. 3542 SV_PbiUnitTime A[21] PBI last unit time(YY/MM/DD HH:MM:SS) 3543 SV_PbiUnitNumber U4[1] PBI last unit number 3544 SV_PbiUnitAvgBall Dia F4[1] PBI last unit average ball diameter 3545 SV_PbiUnitBallDia Min F4[1] PBI last unit minimum Ball Diameter. 3546 SV_PbiUnitBallDia Max F4[1] PBI last unit maximum Ball Diameter 3547 SV_PbiUnitBallDia ErrCnt U4[1] PBI last unit ball diameter error count 3548 SV_PbiUnitBallFind FailCnt U4[1] PBI last unit ball find failure count 3549 SV_PbiUnitAvgXBa llPlcErr F4[1] PBI last unit average X Ball Placement error 3550 SV_PbiUnitXBallPlc ErrMin F4[1] PBI last unit minimum X Ball Placement error (U2) Page - 137 - of 321 Sep 18, 2020 Rev 4.1 Kulicke & Soffa™ SECS/GEM Interface for K&S Ball Bonders Bonder software version x-xx-x-472-series IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Status Variables SVID Name Type Description 3551 SV_PbiUnitXBallPlc ErrMax F4[1] PBI last unit maximum X Ball Placement error 3552 SV_PbiUnitXBallPlc ErrCnt U4[1] PBI last unit X Ball Placement error count 3553 SV_PbiUnitAvgYBa llPlcErr F4[1] PBI last unit average Y Ball Placement error 3554 SV_PbiUnitYBallPlc ErrMin F4[1] PBI last unit minimum Y Ball Placement e 3555 SV_PbiUnitYBallPlc ErrMax F4[1] PBI last unit maximum Y Ball Placement error 3556 SV_PbiUnitYBallPlc ErrCnt U4[1] PBI last unit Y Ball Placement error count 3557 SV_PbiUnitAvgXW edgePlcErr F4[1] PBI last unit average X Stitch Placement error 3558 SV_PbiUnitXWedg ePlcErrMin F4[1] PBI last unit minimum X Stitch Placement error 3559 SV_PbiUnitXWedg ePlcErrMax F4[1] PBI last unit maximum X Stitch Placement error 3560 SV_PbiUnitXWedg ePlcErrCnt U4[1] PBI last unit X Stitch Placement error count 3561 SV_PbiUnitAvgYW edgePlcErr F4[1] PBI last unit average Y Stitch Placement error 3562 SV_PbiUnitYWedg ePlcErrMin F4[1] PBI last unit minimum Y Stitch Placement error 3563 SV_PbiUnitYWedg ePlcErrMax F4[1] PBI last unit maximum Y Stitch Placement error 3564 SV_PbiUnitYWedg ePlcErrCnt U4[1] PBI last unit Y Stitch Placement error count 3565 SV_PbiUnitWedgeF indFailCnt U4[1] PBI last unit stitch Find Failure count 3566 SV_PbiSumStartTi me A[21] PBI summary start time(YY/MM/DD HH:MM:SS). 3567 SV_PbiSumPkgCnt U4[1] Number of Packages Inspected 3568 SV_PbiSumDevCnt U4[1] Number of Devices Inspected 3569 SV_PbiSumWireCn t U4[1] Number of Wires Inspected 3570 SV_PbiSumAvgBall Dia F4[1] Average Ball Diameter 3571 SV_PbiSumStdDev BallDia F4[1] Standard Deviation of Ball Diameters (U2) Page - 138 - of 321 Sep 18, 2020 Rev 4.1 Kulicke & Soffa™ SECS/GEM Interface for K&S Ball Bonders Bonder software version x-xx-x-472-series IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Status Variables SVID Name Type Description 3572 SV_PbiSumBallDia Min F4[1] Minimum Ball Diameter 3573 SV_PbiSumBallDia Max F4[1] Maximum Ball Diameter 3574 SV_PbiSumBallDia ErrCnt U4[1] Ball Diameter error count 3575 SV_PbiSumBallFin dFailCnt U4[1] Ball Find Failure count 3576 SV_PbiSumAvgXB allPlcErr F4[1] Average X Ball Placement error 3577 SV_PbiSumStdDev XBallPlcErr F4[1] Standard Deviation of X Ball Placement errors 3578 SV_PbiSumXBallPl cErrMin F4[1] Minimum X Ball Placement error 3579 SV_PbiSumXBallPl cErrMax F4[1] Maximum X Ball Placement error 3580 SV_PbiSumXBallPl cErrCnt U4[1] X Ball Placement error count 3581 SV_PbiSumAvgYB allPlcErr F4[1] Average Y Ball Placement error 3582 SV_PbiSumStdDev YBallPlcErr F4[1] Standard Deviation of Y Ball Placement errors 3583 SV_PbiSumYBallPl cErrMin F4[1] Minimum Y Ball Placement error 3584 SV_PbiSumYBallPl cErrMax F4[1] Maximum Y Ball Placement error 3585 SV_PbiSumYBallPl cErrCnt U4[1] Y Ball Placement error count 3586 SV_PbiSumAvgXW edgePlcErr F4[1] Average X Stitch Placement error 3587 SV_PbiSumStdDev XWedgePlcErr F4[1] Standard Deviation of X Stitch Placement errors 3588 SV_PbiSumXWedg ePlcErrMin F4[1] Minimum X Stitch Placement error 3589 SV_PbiSumXWedg ePlcErrMax F4[1] Maximum X Stitch Placement error 3590 SV_PbiSumXWedg ePlcErrCnt U4[1] X Stitch Placement error count 3591 SV_PbiSumAvgYW edgePlcErr F4[1] Average Y Stitch Placement error (U2) Page - 139 - of 321 Sep 18, 2020 Rev 4.1 Kulicke & Soffa™ SECS/GEM Interface for K&S Ball Bonders Bonder software version x-xx-x-472-series IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Status Variables SVID Name Type Description 3592 SV_PbiSumStdDev YWedgePlcErr F4[1] Standard Deviation of Y Stitch Placement errors 3593 SV_PbiSumYWedg ePlcErrMin F4[1] Minimum Y Stitch Placement error 3594 SV_PbiSumYWedg ePlcErrMax F4[1] Maximum Y Stitch Placement error 3595 SV_PbiSumYWedg ePlcErrCnt U4[1] Y Stitch Placement error count 3596 SV_PbiSumWedge FindFailCnt U4[1] Stitch Find Failure count 3597 Small Ball Detect U4[1] PM SV: Small ball detected 3598 Bond Height Error U4[1] PM SV: Bond height error detected 3599 PBI Error U4[1] PM SV: PBI error detected 3600 FALSE NSOP U2[1] PM SV: False NSOP detected 3601 AUTOREBOND ATTEMPTS U2[1] PM SV: Auto re-bond attempts 3602 AUTO REBOND NON ATTEMPTS U2[1] PM SV: Auto re-bond non attempts 3603 AUTO REBOND SUCCESSES U2[1] PM SV: Auto re-bond successes 3604 AssistTime F4[1] PM SV: Accumulated assist time = The time when the operator is performing assist to recovery form errors. 3605 VLL FM Detection U4[1] PM SV: Accumulated VLL foreign material detection. 3606 Material Assist U4[1] PM SV: Accumulated material assist. 3607 Schedule DwnTime F4[1] PM SV: Accumulated schedule downtime when operator is changing consumbles: capillary and wire. 3608 UnSchedule DwnTime F4[1] PM SV: Accumulated un-schedule downtime when machine is stopped and receiving assists by operator. 3609 NonScheduleT ime F4[1] PM SV: Accumulated non-schedule time when required to bring machine to be usable after software/hardware upgrade. 3610 TotalTime F4[1] PM SV: Accumulated total time. 3611 Wait for Opr F4[1] PM SV: Accumulated time waiting for operator. 3612 Gross MTBA F4[1] PM SV: Gross MTBA. 3613 Gross Assists U4[1] PM SV: Gross accumulated assists. 3614 SV_LatestErrorCon text U4[1] Non-PM SV: Latest error context. 3615 SV_LatestErrorDevi ce U4[1] Non-PM SV: Latest error device. (U2) Page - 140 - of 321 Sep 18, 2020 Rev 4.1 Kulicke & Soffa™ SECS/GEM Interface for K&S Ball Bonders Bonder software version x-xx-x-472-series IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Status Variables SVID Name Type Description 3616 SV_LatestErrorWire U4[1] Non-PM SV: Latest error wire. 3617 SV_LatestErrorBon d U4[1] Non-PM SV: Latest error bond. 3618 Die Eye Failure U4[1] PM SV: Accumulated die eye points failures. 3619 Lead Eye Failure U4[1] PM SV: Accumulated lead eye points failures. 3620 Substrate Eye Failure U4[1] PM SV: Accumulated substrate eye points failures. 3621 Long Tails U4[1] PM SV: Accumulated long tail exceptions in SSB process. PM SV: Accumulated long tail exceptions in SSB process 3622 FALSE NSOL U2[1] PM SV: Accumulated false NSOL reported by BITS. 3623 NetDevicesBonded U4[1] PM SV: Accumulated PM Net Device Bonded. 3624 SV_PbiUnitBallDia PlcFailRate F4[1] PBI Unit Ball Diameter Placement Fail Rate 3625 SV_PbiSumBallDia PlcFailRate F4[1] PBI Sum Ball Diameter Placement Fail Rate 3626 SV_PM_Bump_NS OP U4[1] PM statistic for ssb bump nsop error. 3627 SV_PM_Bump_SH TL U4[1] PM statistic for ssb bump short tail error. 3628 SV_PM_Bump_SB D U4[1] PM statistic for ssb bump small ball detected error. 3629 SV_PM_Bump_Lift U4[1] PM statistic for ssb bump lift error. 3630 SV_PM_LBD U4[1] Large ball error statistics 3631 SV_PM_Bump_LB D U4[1] Bump large ball error staistics 3632 SV_PM_AUTO_SH TL_RECV_ATTEM PTS U4[1] Attempts that auto recovery tries after SHTL 3633 SV_PM_AUTO_SH TL_RECV_SUCCE SSES U4[1] Success that auto recovery done after SHTL 3634 SV_PM_AUTO_EF O_OPEN_RECV_A TTEMPTS U4[1] Attempts that auto recovery tries after EFO OPEN 3635 SV_PM_AUTO_EF O_OPEN_RECV_S UCCESSES U4[1] Success that auto recovery done after EFO OPEN 3636 SV_PM_NSOL_RE WORK_ATTEMPT S U4[1] PM statistic for NSOL Auto Rework attempts. (U2) Page - 141 - of 321 Sep 18, 2020 Rev 4.1 Kulicke & Soffa™ SECS/GEM Interface for K&S Ball Bonders Bonder software version x-xx-x-472-series IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Status Variables SVID Name Type Description 3637 SV_PM_NSOL_RE WORK_SUCCESS U4[1] PM statistic for NSOL Auto Rework success. 3638 SV_PM_AUTO_SH TL_FALSE_ALARM U4[1] False shtl alarm count 3639 SV_PM_IndexVacu um U4[1] PM SV: Number of Index Vacuum Error 3641 SV_PM_DRPAllErr ors U4[1] Accumulated all the DRP errors 3650 SV_PM_Center_De v_1stWire_2ndBnd _BH F4[1] First Wire Second Bond Bond Height 3651 SV_PM_WireInspe ctionError U4[1] PM SV: Number of wire inspection errors 3660 SV_RailHeightVal F4[1] Rail height value 3661 SV_RailHeightState I4[1] Rail height state 3662 SV_PbiUnitBallFind IgnoreCnt U4[1] Ball find ignore count 3663 SV_PbiSumBallFin dIgnoreCnt U4[1] Ball Find Ignore count 3670 SV_Die_Eye_Fail_ Skip_Filter U1[1] Die Eye Fail skip device filter: By Count/By Time/By Count&By Time 3671 SV_Lead_Eye_Fail _Skip_Filter U1[1] Lead Eye Fail skip device filter: By Count/By Time/ By Count&By Time 3672 SV_Die_LTOL_Fail _Skip_Filter U1[1] Die Line Tolerance Fail skip device filter: By Count/By Time/ By Count&By Time 3673 SV_Lead_LTOL_Fa il_Skip_Filter U1[1] Lead Line Tolerance Fail skip device filter: By Count/By Time/ By Count&By Time 3674 SV_NSOP_Skip_Fil ter U1[1] NSOP skip device filter: By Count/By Time/ By Count&By Time 3675 SV_NSOL_Skip_Fil ter U1[1] NSOL skip device filter: By Count/By Time/ By Count&By Time 3676 SV_SHTL_Skip_Filt er U1[1] SHTL skip device filter: By Count/By Time/ By Count&By Time 3677 SV_Wire_Feed_Err _Skip_Filter U1[1] Wire Feed Error skip device filter: By Count/By Time/ By Count&By Time 3678 SV_PBI_Wire_Stop _Skip_Filter U1[1] PBI Eire Stop Error skip device filter: By Count/By Time/ By Count&By Time 3679 SV_Cover_Gas_Fai l_Skip_Filter U1[1] Cover Gas Fail skip device filter: By Count/By Time/ By Count&By Time (U2) Page - 142 - of 321 Sep 18, 2020 Rev 4.1 Kulicke & Soffa™ SECS/GEM Interface for K&S Ball Bonders Bonder software version x-xx-x-472-series IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Status Variables SVID Name Type Description 3680 SV_DRP_Errors_S kip_Filter U1[1] DRP Error skip device filter: By Count/By Time/ By Count&By Time 3700 SV_PM_SSB_Stitc h_NSOL U4[1] PM SV: SSB Stitch NSOL 3701 SV_PM_SSB_Stitc h_SHTL U4[1] PM SV: SSB Stitch SHTL 3702 SV_PM_DevicesAu toSkippedTotal U4[1] PM SV: Total Devices Auto Skipped 3703 SV_PM_DevicesAu toSkippedPRS U4[1] PM SV: PRS Devices Auto Skipped 3704 SV_PM_DevicesAu toSkippedNSOP U4[1] PM SV: NSOP Devices Auto Skipped 3705 SV_PM_DevicesAu toSkippedNSOL U4[1] PM SV: NSOL Devices Auto Skipped 3706 SV_PM_DevicesAu toSkippedSHTL U4[1] PM SV: SHTL Devices Auto Skipped 3707 SV_PM_DevicesAu toSkippedRejEP U4[1] PM SV: Reject Eye Point Devices Auto Skipped 3708 SV_PM_DevicesAu toSkippedProbeNo Die U4[1] PM SV: Probe No Die Devices Auto Skipped 3709 SV_PM_DevicesAu toSkippedPBI U4[1] PM SV: PBI Devices Auto Skipped 3710 SV_PM_DevicesAu toSkippedDRP U4[1] PM SV: DRP Devices Auto Skipped 3711 SV_PM_DevicesAu toSkippedCoverGa s U4[1] PM SV: Cover Gas Devices Auto Skipped 3712 SV_PM_DevicesAu toSkippedWireFeed U4[1] PM SV: Wire Feed Devices Auto Skipped 3713 SV_PM_DevicesAu toSkippedIBB U4[1] PM SV: IBB Devices Auto Skipped 3714 SV_PM_DevicesAu toSkippedUnionDev ice U4[1] PM SV: Union Device Devices Auto Skipped 3715 SV_PM_DevicesAu toSkippedVacuumP ortEmpty U4[1] PM SV: Vacuum Port Empty Devices Auto Skipped 3790 SV_First_Bond_Se g_Mode U1[1] First bond seg mode: 0-Classic, 1-ProBond (U2) Page - 143 - of 321 Sep 18, 2020 Rev 4.1 Kulicke & Soffa™ SECS/GEM Interface for K&S Ball Bonders Bonder software version x-xx-x-472-series IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Status Variables SVID Name Type Description 3791 SV_Second_Bond_ Seg_Mode U1[1] Second bond seg mode: 0-Classic, 1-ProStitch 3800 SV_BONDING_PA RM_GROUP_LIST L[N] List of bonding parameter group. Need enable EC1239 to update value. 3801 SV_1ST_BOND_TI ME L[N] List of the first bond time. Need enable EC1239 to update value. 3802 SV_1ST_USG_BO ND_CURRENT L[N] List of the first USG bond current. Need enable EC1239 to update value 3803 SV_1ST_BOND_F ORCE L[N] List of the first bond force. Need enable EC1239 to update value. 3804 SV_1ST_TIP L[N] List of the first Tip. Need enable EC1239 to update value. 3805 SV_1ST_CV L[N] List of the first CV. Need enable EC1239 to update value. 3806 SV_2ND_BOND_TI ME L[N] List of the second bond time. Need enable EC1239 to update value. 3807 SV_2ND_USG_BO ND_CURRENT L[N] List of the second USG bond current. Need enable EC1239 to update value. 3808 SV_2ND_BOND_F ORCE L[N] List of the second bond force. Need enable EC1239 to update value. 3809 SV_2ND_TIP L[N] List of the second Tip. Need enable EC1239 to update value. 3810 SV_2ND_CV L[N] List of the second CV. Need enable EC1239 to update value. 3811 SV_FAB_SIZE L[N] List of fab size. Need enable EC1239 to update value. 3812 SV_EFO_CURREN T L[N] List of EFO current. Need enable EC1239 to update value. 3813 SV_KINK_HEIGHT L[N] List of kink height. Need enable EC1239 to update value. 3814 SV_REVERSE_MO TION L[N] List of reverse motion. Need enable EC1239 to update value. 3815 SV_LOOP_FACTO R L[N] List of loop factor. Need enable EC1239 to update value. 3816 SV_PM_RefDriftFai lure U4[1] Number of Reference Drift failures. 3817 ML_Load_Port_Stat us BL[1] Left maghandler loading tray outer sensor status. 3818 ML_Unload_Port_S tatus BL[1] Left maghandler unloading tray outer sensor status. 3819 MR_Load_Port_Sta tus BL[1] Right maghandler loading tray outer sensor status. 3820 MR_Unload_Port_S tatus BL[1] Right maghandler loading tray outer sensor status. (U2) Page - 144 - of 321 Sep 18, 2020 Rev 4.1 Kulicke & Soffa™ SECS/GEM Interface for K&S Ball Bonders Bonder software version x-xx-x-472-series IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Status Variables SVID Name Type Description 3821 AGV_Control_Statu s BL[1] AGV control ON/OFF. 3822 AGV_VALID_Statu s BL[1] AGV valid status. (1 = AGV is present, 0 = AGV is not present) 3823 ML_Load_Limit_Sn s_Status BL[1] Left maghandler loading tray limit sensor status. 3824 MR_Load_Limit_Sn s_Status BL[1] Right maghandler loading tray limit sensor status. 3825 OHT_Control_Statu s BL[1] Status change of OHT magazine load control. 3829 SV_IncompleteCal A[600] Incomplete calibration items. 3830 SV_LATEST_SUC CESSFUL_CAL A[81] The latest successful calibration item 3831 SV_Package_Bondi ng_Status U1[1] Bonder Status 3840 SV_Lot_State B[1] Current Lot Status 3841 SV_Lot_ID A[31] Current Lot ID 3842 SV_Lot_Remaning _Mag_Num I4[1] Current Lot Remaining Mag Number 3843 SV_Lot_Total_Mag _Num I4[1] Current Lot Total Mag Number 3844 SV_Lot_OPID A[31] Current Lot Operator ID 3850 SV_WIRE_USAGE _PER_UNIT F4[1] Average Wire Usage per Unit 3851 SV_AVAILABLE_B OND_UNIT_CURR _SPOOL U4[1] Avaiable Bond Unit that can be bonded with current wire spool 3852 SV_WIRE_USAGE _DEV_BOND F4[1] Wire Usage Device Bond 3853 SV_WIRE_USAGE _NON_DEV_BOND F4[1] Wire Usage Non Device Bond 3854 SV_Remove_Wire_ Spool_ID A[20] Removed Wire Spool ID 3855 SV_Install_Wire_Sp ool_ID A[20] Installed Wire Spool ID 3856 SV_WireSpoolMoni _OPID A[20] Lot OPID 3857 SV_SpoolDevicesB onded U4[1] The bonded device number of current wire spool 3858 SV_PrevWireUsage F4[1] The number of used wire before wire spool is replaced (U2) Page - 145 - of 321 Sep 18, 2020 Rev 4.1 Kulicke & Soffa™ SECS/GEM Interface for K&S Ball Bonders Bonder software version x-xx-x-472-series IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Status Variables SVID Name Type Description 3859 SV_DRP_Errors_S kip_Mode U2[1] DRP errors auto skip mode 3860 SV_Auto_Err_Skip_ Sub_Coordinate A[10] Auto skip device coordinate with format(Col-Row) 3861 SV_Auto_Err_Skip_ Event_CL U2[1] Auto skip error’s event classification 3862 SV_NSOP_Skip_M ode U2[1] NSOP skip mode 3863 SV_NSOL_Skip_M ode U2[1] NSOL skip mode 3864 SV_SHTL_Skip_Mo de U2[1] SHTL skip mode 3865 SV_Die_Eye_Fail_ Skip_Mode U2[1] Die Eye Fail skip mode 3866 SV_Lead_Eye_Fail _Skip_Mode U2[1] Lead Eye Fail skip mode 3867 SV_Die_LTOL_Fail _Skip_Mode U2[1] Die Line TOL Fail skip mode 3868 SV_Lead_LTOL_Fa il_Skip_Mode U2[1] Lead Line TOL Fail skip mode 3869 SV_Wire_Feed_Err _Skip_Mode U2[1] Wire Fees Error skip mode 3870 SV_PBI_Wire_Stop _Skip_Mode U2[1] PBI Wire Stop Error skip mode 3871 SV_ID_INFO A[81] Grasped ID info 3872 SV_Wire_Clamp_T otal_Usage U4[1] Wire Clamp Total Usage 3873 SV_Wire_Clamp_Li fetime F4[1] Wire Clamp Lifetime 3874 SV_CM_LOG_NAM E A[81] Name of customized log file 3875 SV_CM_LOG_STA RTTIME A[15] Start time of customized log file (yyyymmddhhmmss) 3876 SV_CM_LOG_END TIME A[15] End time of customized log file (yyyymmddhhmmss) 3880 SV_NumAvlWireIns pIds U1[1] Wire Inspection: Number of available wire inspection IDs 3881 SV_NumTaughtWir eInspIds U1[1] Wire Inspection: Number of taught wire inspection IDs (U2) Page - 146 - of 321 Sep 18, 2020 Rev 4.1 Kulicke & Soffa™ SECS/GEM Interface for K&S Ball Bonders Bonder software version x-xx-x-472-series IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Status Variables SVID Name Type Description 3882 SV_NumAssgndWir eInspIds U1[1] Wire Inspection: Number of assigned wire inspection IDs 3883 SV_WireInspUnitTi me A[21] Wire Inspection: Unit time(YY/MM/DD HH:MM:SS) 3884 SV_WireInspUnitFi ndFailCnt U4[1] Wire Inspection: Find failure count for last unit 3885 SV_WireInspUnitAv gWireSway F4[1] Wire Inspection: Average wire sway for last unit 3886 SV_WireInspSumSt artTime A[21] Wire Inspection: Summary 3887 SV_WireInspSumP kgCnt U4[1] Wire Inspection: Number of Packages wire inspected 3888 SV_WireInspSumD evCnt U4[1] Wire Inspection: Number of Devices wire inspected 3889 SV_WireInspSumW ireInspCnt U4[1] Wire Inspection: Summary inspection count 3890 SV_WireInspSumFi ndFailCnt U4[1] Wire Inspection: Summary find failure count 3891 SV_WireInspSumEr rCnt U4[1] Wire Inspection: Summary wire sway error count 3892 SV_WireInspIDInsp Cnt U4[1] Wire Inspection: Inspect count for specific ID 3893 SV_WireInspIDFind FailCnt U4[1] Wire Inspection: Find failure count for specific ID 3894 SV_WireInspIDErrC nt U4[1] Wire Inspection: Error count for specific ID 3895 SV_WireInspIDAvg WireSway F4[1] Wire Inspection: Average wire sway for specific ID 3896 SV_WireInspIDStd DevWireSway F4[1] Wire Inspection: Standard deviation for specific ID 3897 SV_WireInspIDWire SwayMin F4[1] Wire Inspection: Min wire sway for specific ID 3898 SV_WireInspIDWire SwayMax F4[1] Wire Inspection: Max wire sway for specific ID 4016 SV_1ST_FORCE_ PROFILING L[N] List of the first force profiling. Need enable EC1239 to update value. 4017 SV_1ST_X_SCRU B L[N] List of the first X scrub. Need enable EC1239 to update value. 4018 SV_1ST_Y_SCRU B L[N] List of the first Y scrub. Need enable EC1239 to update value. (U2) Start time(YY/MM/DD HH:MM:SS) Page - 147 - of 321 Sep 18, 2020 Rev 4.1 Kulicke & Soffa™ SECS/GEM Interface for K&S Ball Bonders Bonder software version x-xx-x-472-series IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Status Variables SVID Name Type Description 4019 SV_1ST_SCRUB_ CYCLES L[N] List of the first scrub cycles. Need enable EC1239 to update value. 4020 SV_2ND_TAIL_SC RUB_MODE L[N] List of the second tail scrub mode. Need enable EC1239 to update value. 4021 SV_2ND_TAIL_XY _SCRUB L[N] List of the second tail XY scrub. Need enable EC1239 to update value. 4022 SV_2ND_TAIL_SC RUB_CYCLES L[N] List of the second tail scrub cycles. Need enable EC1239 to update value. 4023 SV_BUMP_BOND_ POWER L[N] List of bump Bond power. Need enable EC1239 to update value. 4024 SV_BUMP_BOND_ FORCE L[N] List of bump bond force. Need enable EC1239 to update value. 4025 SV_BUMP_FORCE _PROFILING L[N] List of bump force profiling. Need enable EC1239 to update value. 4026 SV_BUMP_SCRUB _CYCLES L[N] List of bump scrub cycles. Need enable EC1239 to update value. 4027 SV_BUMP_BOND_ OFFSET L[N] List of bump bond offset. Need enable EC1239 to update value. 4028 SV_LOOP_FAB_SI ZE L[N] List of loop fab size. Need enable EC1239 to update value. 4029 SV_BITS_ENABLE D L[N] List of BITS enable status. Need enable EC1239 to update value. 4030 SV_Shuffled_LogFil e_OriginalNam A[81] The shuffled log file original name. Will be updated while CE_LogFile_Shuffled occurred. 4031 SV_Shuffled_LogFil e_TargetNam A[81] The shuffled log file target name. Will be updated while CE_LogFile_Shuffled occurred (U2) Figure 58 – K&S Model Power Series Automatic Ball Bonder and K&S Model Gen-S Automatic Ball Bonder Shared Status Variables 6.3 K&S Model Power Series Automatic Ball Bonder and K&S Model Gen-S Automatic Ball Bonder Shared Equipment Constants The Equipment Constant values (ECVs) and associated Equipment Constant IDs (ECIDs) shared by K&S Model Power Series Automatic Ball Bonder and K&S Model Gen-S Automatic Ball Bonder are described in this section. Page - 148 - of 321 Sep 18, 2020 Rev 4.1 Kulicke & Soffa™ SECS/GEM Interface for K&S Ball Bonders Bonder software version x-xx-x-472-series ECID (U2) 1000 IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Equipment Constants Name Type Description Default Communications State B[1] 1001 Default State B[1] 1002 Communication State Model BL[1] 1003 BL[1] 1006 1007 1008 Disable Process Program Load Inquire Establish Communications Timeout MDLN SOFTREV Starting SVID 1009 DeviceID U2[1] 1010 MaxSpool Transmit U4[1] 1011 OverWriteSpool BL[1] 1012 Comm State Callback Response Control State Callback Response Load Inquire Callback Response Download Callback Response Upload Callback Response Directory Callback Response Validate Comm Start Callback Response Remote Command Callback Response I4[1] 1005 1013 1014 1015 1016 1017 1018 1019 Control U2[1] A[7] A[32] U2[1] I4[1] I4[1] I4[1] I4[1] I4[1] I4[1] I4[1] The initial communicatisons state. Host read-only. 1 = COMM DISABLED 2 = COMM ENABLED/NOTCOMMUNICATING 3-255 = Reserved The initial control state. Host read-only. 1 = OFFLINE/EQUIPMENT OFFLINE 2 = OFFLINE/ATTEMPTING TO GO ONLINE 3 = OFFLINE/HOST OFFLINE 4 = ONLINE/LOCAL 5 = ONLINE/REMOTE 6-63 = Reserved Flag used to enable or disable the GEM Communication State Model. If the flag is set to FALSE, then the S1,F1 Are You There Request (R) /S1,F2 On Line Data (D) transaction is used instead of the S1,F13 Establish Communications Request (CR)/ S1,F14 Establish Communications Request Acknowledge (CRA) transaction to establish communications. The default value is set to TRUE. Flag used to disable the requirement of process program load inquire before equipment is sent a multi-block process program. The default value of this flag is zero (false). The length of time, in seconds, of the interval between attempts to send S1,F13 Establish Communications Request (CR) messages when establishing communications. Equipment model type. Host read-only. Software revision. Host read-only. The start variable ID number for status variables. Host readonly. The device ID which is used for SECS II messages. Host readonly. Maximum number of messages to transmit when an S6,F23 Request Spooled Data (RSD) message is received from the host. If 0, no limit. Either overwrite the spool when spooling area becomes full, or stop adding messages to the spool. Default response if no application code callback is registered for communication state changes. Default response if no application code callback is registered for control state changes. Default response if no application code callback is registered for host initiated process program download inquiries. Default response if no application code callback is registered for host initiated process program download requests. Default response if no application code callback is registered for host initiated process program upload requests. Default response if no application code callback is registered for host initiated process program directory requests. Default response if no application code callback is registered for host attempting to establish communications. Default response if no application code callback is registered for remote commands from host. Page - 149 - of 321 Sep 18, 2020 Rev 4.1 Kulicke & Soffa™ SECS/GEM Interface for K&S Ball Bonders Bonder software version x-xx-x-472-series ECID (U2) 1020 IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Equipment Constants Name Type Description Default S1F2 Response Default Offline Control State Starting CEID I4[1] Default response to host sending S1F1. B[1] 1023 Default Enabled BL[1] 1024 Number of SVIDs U2[1] 1025 B[1] 1026 1027 1028 1029 1032 Default Online Control State Starting ALID Starting RPTID Starting DataID Last SVID S6 F11 Reply New control state when host fails to respond to or denies an operator initiated attempt to go on-line. The start variable ID number for collection events. Host readonly. Flag used to enabled disable HSMS communications upon equipment startup. Valid only when Using HSMS equipment constant is TRUE. Maximum number of status variables that can be configured on equipment. This EC and Starting SVID define the valid range of SVIDs. New control state when equipment goes online. 1033 1034 Starting DVID Number of DVIDs U2[1] U2[1] 1035 SpoolMode BL[1] 1036 1037 EC_DefOpeMode EC_OpeTechIdOpt U2[1] I2[1] The start variable ID number for alarms. Host read-only. The start variable ID number for reports. Host read-only. The start variable ID number for data IDs. Host read-only. The ending variable ID number for data IDs. Host read-only. Flag used to determine if equipment should expect a reply to S6F11 messages. The starting ID number for data values. Host read-only. Maximum number of data values that can be configured on equipment. This EC and Starting DVID define the valid range of DVIDs. Host read-only. Message spooling control (except Stream 1, i.e., S1F1, S1F13). FALSE = disable spooling TRUE = enable spooling Default Ope mode Ope down time configuration 1038 EC_OpeModeChgT mr EC_OpeAlrmClrTm r EC_PrevOpeMode RcmdStartTmr Tool Usage Warning Level I4[1] Ope change timer I4[1] Ope alarm clear timer U2[1] I2[1] F4[1] Tool Usage Bond Limit Tool Usage Hour Limit EC_BondProximity Check EC_WireSpoolLeng th EC_PbiState EC_PbiBallSizeInsp State EC_PbiBallLocInsp State U4[1] Previously saved OPE mode Process start (remote command) timer. Default as 10 seconds. Tool usage level in percent (< 100%) that must be reached before the collection event Approaching Tool Usage Limit is sent to the host. Tool usage bond limit count. U4[1] Tool Usage Hour Limit BL[1] Tool usage time limit in hours. F4[1] BL[1] BL[1] Total wire length. It is the wire spool length that is normally specified in the Wire Usage dialog. PBI enable. (TRUE = On; FALSE = Off) PBI: Ball size inspection. (TRUE = On; FALSE = Off) BL[1] PBI: Ball placement inspection. (TRUE = On; FALSE = Off) 1021 1022 1039 1040 1041 1042 1043 1044 1045 1046 1047 1048 1049 HSMS U2[1] U2[1] U2[1] U2[1] U2[1] BL[1] Page - 150 - of 321 Sep 18, 2020 Rev 4.1 Kulicke & Soffa™ SECS/GEM Interface for K&S Ball Bonders Bonder software version x-xx-x-472-series ECID (U2) 1050 1051 1052 1053 IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Equipment Constants Name Type Description EC_PbiWedgeInsp Enable EC_PbiInspUnit EC_PbiActualBallDi a EC_PbiBallFindDia Tol BL[1] PBI: Wedge placement inspection. (TRUE = On; FALSE = Off) B[1] F4[1] PBI: Inspection unit. (0 = Package; 1 = Device) PBI: Actual ball diameter. F4[1] PBI: Ball find diameter tolerance. The Max Value for this ECID is the current value of ECID 1052 (EC_PbiActualBallDia) 1054 1055 1056 1057 1058 1059 1060 1061 1062 1063 1064 1065 1066 1067 1068 1069 1070 1071 1072 1073 1074 EC_PbiAutoThresh old EC_PbiBinThreshol d EC_PbiNumSample s EC_PbiSamplingM ethod EC_PbiRandomSa mpling EC_PbiSamplePerc ent EC_PbiReqMeasur ePerWire EC_PbiTriesPerWir eMax EC_PbiRealignStat e EC_PbiBallDiaTol BL[1] Can only be modified if there is a process program in RAM. If not, returns 6 in EAC return PBI: Auto Threshold (TRUE = On; FALSE = Off) F4[1] PBI: Binary threshold value (0 - 255) U2[1] PBI: Sample every n units. B[1] BL[1] PBI: Sampling method (0 = last n wires; 1 = user selected wires; 2 = all wires) PBI: Random sampling (TRUE = On; FALSE = Off) F4[1] PBI: Sample percentage (1 - 100) U2[1] PBI: Required measurement per wire (value >= 1) I2[1] PBI: Maximum tries per wire (value >= 1) BL[1] PBI: Realign before inspection (TRUE = On; FALSE = Off) F4[1] EC_PbiBallXLocTol EC_PbiBallYLocTol EC_PbiFailStopMo de EC_ApplyParmLimi ts F4[1] F4[1] B[1] INHIBIT_AUTO_RU N_WITHOUT_PBI EC_PbiSkipDevice EC_PbiProcNomDi a EC_PbiBallSizeBia sBasis EC_PbiBallSizeBia sValid EC_PbiBallSizeBia sValue EC_PbiExtBallFind ParmSetID BL[1] PBI: Ball diameter inspection tolerance (value = percentage of nominal ball diameter) PBI: Ball X placement inspection tolerance. PBI: Ball Y placement inspection tolerance. PBI: Failure machine stop mode (0 = don’t stop on failure; 1 = stop on unit average failure; 2 = stop on any inspection failure) Flag used to enable or disable application of parameter limits to the current program in RAM after downloading bond parameter limits files to the bonder. Inhibit auto run without PBI ball signature reteach U2[1] F4[1] Support PBI Skip Device PBI: Process Nominal Ball Diameter. B[1] PBI: Ball Size Biasing Basis. BL[1] PBI: Ball Size Bias Valid Flag. F4[1] PBI: Ball Size Bias Value. B[1] PBI: Ext Ball Find Parm Set ID. BL[1] Page - 151 - of 321 Sep 18, 2020 Rev 4.1 Kulicke & Soffa™ SECS/GEM Interface for K&S Ball Bonders Bonder software version x-xx-x-472-series ECID (U2) 1075 1076 1077 1078 1079 1080 1081 1082 1083 1084 1085 1086 IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Equipment Constants Name Type Description EC_PBILogFileDay s U2[1] EC_TimeBeforePo werSave EC_PowerSaveCon fig EC_TimeBeforeBon ding EC_Heaters EC_AirGuide EC_NUMERIC_LIM IT_OPTION EC_ToolUsageBon dCountType EC_SaveComCtrlSt ate U4[1] PBI: Maximum age for archived PBI log files. PBI log files that have resided on the number longer than the number of days specified by EC_PBILogLifeDays will be deleted from the bonder and their entries from PBILIST.LOG Change in TimeBeforePowerSave BL[1] PowerSaveConfiguration ON/OFF U4[1] Change in TimeBeforeBonding BL[1] BL[1] U1[1] Heaters Yes/No Air Guide Yes/No The bonder shall allow the host to read & modify the configuration for Numeric Limit Action. Counter Type: 0=Down, 1=Up EC_Worklight EC_Monitor EC_EnterHitExtAcc ess BL[1] BL[1] BL[1] U4[1] BL[1] TRUE = Attempt to resume to the last known GEM Communication and Control State after a power failure or other power cycle FALSE = Off Work light Yes/No Monitor Yes/No Flag used to allow execution of ENTER_HIT remote command at any operational mode except at Auto Run mode. FALSE = Default setting. ENTER_HIT remote command is restricted at Idle and Sequence Stop mode. TRUE = Allows ENTER_HIT remote command at any operational mode except Auto Run mode. (Note: The existing requirement to inhibit Auto in Sequence Stop mode remains the same.) 1087 1088 1089 1090 1091 1092 1093 Note: In the Modify Equipment Constant dialog this equipment constant will have the label 'Enter HIT Command Extended Access' PBI: Breakpoint Enable State EC_PbiBrkPntsEna bled EC_OutputMagEjec tWarning EC_EjectThreshold Warning EC_EjectThreshold BL[1] EC_WireCtrlStartSt ate EC_WireCtrlStartSit e EC_WireCtrlStartWi re U1[1] If set to TRUE, the Output Mag Eject Warning will be displayed when an output magazine is ejected If set to TRUE, the Eject Threshold Warning will displayed when the Eject Threshold of a magazine is reached The number of strips which are left to be ejected before the the output magazine is full. It is the triggering point for Eject Threshold Warning. NOTE: Max number up to 5 Start Control Mode. (0 = OFF; 1 = ONCE; 2 = ALWAYS) U2[1] Start Device. U2[1] Start Wire. BL[1] BL[1] U1[1] Page - 152 - of 321 Sep 18, 2020 Rev 4.1 Kulicke & Soffa™ SECS/GEM Interface for K&S Ball Bonders Bonder software version x-xx-x-472-series ECID (U2) 1094 1095 1096 1097 1098 1099 1100 IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Equipment Constants Name Type Description EC_WireCtrlStopSt ate EC_WireCtrlStopSit e EC_WireCtrlStopWi re EC_WireCtrlStopAc tion EC_UsgImpedance HHLimit EC_UsgImpedance HLLimit Process Program Write Protect U1[1] Stop Control Mode. (0 = OFF; 1 = ONCE; 2 = ALWAYS) U2[1] Stop Device. U2[1] Stop Wire. BL[1] Action After Stop. (0 = NONE; 1 = GOTO SEQ STOP) U1[1] USG impedance high frequency high limit U1[1] USG impedance high frequency low limit. BL[1] Flag used to indicate that the process program name and its components residing on equipment should not be overwritten by the host downloading a program with the same name or component name. TRUE = enable write protect FALSE = disable write protect Maximum size, in bytes, of a concatenated process program that can be uploaded to host without being compressed. Set to zero (0) to disable compression. NOTE: On download, the equipment automatically detects whether a process program is compressed and reads it accordingly. Storage device where the process program is stored. 0 = DISK 1 = RAM Storage device where the process program will be stored. 0 = DISK 1 = RAM 2 = DISK & RAM 3 = RAM without MHS Enable/disable Process program verification. (0 = OFF, 1 = ON) 1101 Process Program Compression Threshold U4[1] 1102 Upload Device Source I4[1] 1103 Download Device Target I4[1] 1104 KGemPP_EC_PP_ Verify EC_AutoUsgCal I4[1] EC_UsgAutoCalSc anMode EC_UsgAutoCalSc anInterval EC_LinktestInterval U1[1] EC_PrivAutoUsgCa lOnOff EC_PbiNSOPEvalu ationState EC_PbiBallAssocSt ate EC_KgemPBIBallId EC_PbiBallNSOPE valuationState EC_PbiNSOPStop Mode BL[1] Link test interval. UNIT: Seconds. (MIN = 0; DEFAULT = 0; MAX = 120) Master enable switch for USG impedance monitor feature. BL[1] PBI: NSOP evaluation state BL[1] PBI: ball association state U1[1] BL[1] PBI: ball id PBI: ball NSOP evaluation state(0 = OFF, 1 = ON) BL[1] PBI: NSOP stop mode (0 = OFF, 1 = ON) 1105 1106 1107 1108 1109 1111 1112 1113 1115 1116 BL[1] U4[1] U1[1] Enable/disable Auto periodic USG calibration. (0 = OFF, 1 = ON) USG Auto scan mode. (0 = After device, 1 = After leadframe/strip) Scan interval during Auto periodic USG calibration. Page - 153 - of 321 Sep 18, 2020 Rev 4.1 Kulicke & Soffa™ SECS/GEM Interface for K&S Ball Bonders Bonder software version x-xx-x-472-series ECID (U2) 1117 1118 1119 1120 1121 1122 1123 1124 1125 1126 1127 1128 1129 1130 1131 1132 1133 1134 1135 1136 1137 1138 1140 1141 1142 1145 1146 IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Equipment Constants Name Type Description EC_PBIDelayBefor eFirstCapture EC_StripInject EC_AutoIndex EC_EFO_Current_ Offset EC_EFO_Wand_lif etime EC_LoopHeightSca leFactor EC_LoopHeightOffs et EC_BondForceOffs et EC_Tool_Change_ Setting EC_Tool_Usage_S etting EC_Cover_Gas_Co ntrol_Type EC_Save_PP_to_C U2[1] PRS delay before PBI inspection per bond BL[1] BL[1] F4[1] Enable/disable strip inject. (0 = OFF, 1 = ON) Enable/disable auto index. (0 = OFF, 1 = ON) Change EFO Current Offset F4[1] EFO wand life time checking F4[1] Loop Height Scale Factor F4[1] Loop Height Offset I4[1] Bond Force Offset U1[1] EC_Load_PP_Opti on EC_Wire_Lifetime EC_Auto_Logoff_Pr ivilege_User EC_Priv_Level U1[1] EC_ClearFADataB utton EC_User_ID_Priv_ Level BL[1] Tool Change Setting 0=Normal/1=Lockout/2=Forced Tool Usage Setting 0=PP/1=MDP Cover gas control type 0=Manual/1=ON_OFF Save PP to C option 0=Not Allowed/1=Allowed. Load PP by file name or long name 0=Load by file name/1=Load by long name Control wire life time setting Auto Logoff Privilege User 0=OFF/1=ON Privilege level 1=Anyone/2=Operator/3=Supervisor/4=Administrator Enable/Disable clear FA data button EC_AutoJogInMag Ctrl EC_AccessViolatio nContCtrl EC_AutomationJob Ctrl EC_LoadPPMethod EC_DefaultWireCla mpProfile EC_FocusAdjState EC_FocusAdjLimit EC_PART_RECEIV E_WAIT_TIME EC_PART_EJECT_ WAIT_TIME U1[1] User ID Privilege Level 1=Anyone/2=Operator/ 3=Supervisor/4=Engineer/ 5=Administrator Control of auto jogging magazine U1[1] Control of continue option support in access violation alarm U1[1] Control of automation job support U1[1] U1[1] BL[1] U2[1] U4[1] Control how to load process program for Next Job Control option setting of Default Wire Clamp Profile 0=Standard/ 1=Gentle/2=Super Gentle Focus Adjustment State ON/OFF Change in Focus Adjustment Limit Part missing timer U4[1] Part jam timer U1[1] U1[1] U1[1] F4[1] U1[1] U1[1] U1[1] Page - 154 - of 321 Sep 18, 2020 Rev 4.1 Kulicke & Soffa™ SECS/GEM Interface for K&S Ball Bonders Bonder software version x-xx-x-472-series ECID (U2) 1147 1148 1149 1150 1151 1152 1153 1154 1155 1156 1157 1158 1159 1160 1161 1162 1163 1164 1165 1166 1167 1170 1171 1172 1173 1174 IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Equipment Constants Name Type Description EC_MES_CTRL U1[1] EC_PPSelectMode EC_Host_Reply_Ti meout EC_MotorStopTime BeforePowerSave EC_MotorStopTime BeforeBonding EC_MotorStopPow erSaveConfig EC_MotorStopHeat ers EC_MotorStopIllumi nation EC_MotorStopAirG uide EC_MotorStopMoni tor EC_MotorStopBlow erKit EC_Illumination EC_BlowerKit EC_XRegSeekAuto RetryCount EC_XRegSeekAuto RetryDistance EC_P1_AccessMod e EC_P2_AccessMod e EC_P3_AccessMod e EC_P4_AccessMod e EC_AUTO_LOGOF F_TIME EC_PRD_TIME_G RACE_PERIOD EC_Opr_Align_Pos _Limit_Check_Stat e EC_Die_Opr_Align _Pos_Limit EC_LeadSub_Opr_ Align_Pos_Limit EC_Substrate_Info _Display_Name EC_Substrate_Info _Data I4[1] U1[1] MES control 0 = disable 1 = enable Process program select mode Request Mag ID timeout U4[1] Change in MotorStopTimeBeforePowerSave U4[1] Change in MotorStopTimeBeforeBonding BL[1] MotorStopPowerSaveMode ON/OFF BL[1] MotorStopHeaters Yes/No BL[1] MotorStopIllumination Yes/No BL[1] MotorStopAirGuide Yes/No BL[1] MotorStopMonitor Yes/No BL[1] MotorStopBlowerKit Yes/No BL[1] BL[1] U4[1] Illumination Yes/No BlowerKit Yes/No X registration extra retry count U4[1] X registration extra retry distance U1[1] Access mode of input load tray U1[1] Access mode of output unload tray U1[1] Access mode of input unload tray U1[1] Access mode of output load tray I4[1] ECID for auto logoff privilege user time I4[1] BL[1] ECID for production time grace period, which is the time from engineering mode to production mode. Operator align position limit check state F4[1] Die reference system operator align position limit F4[1] Lead/Substrate reference system operator align position limit A[15] The sub info display name in GUI A[80] The substrate information data Page - 155 - of 321 Sep 18, 2020 Rev 4.1 Kulicke & Soffa™ SECS/GEM Interface for K&S Ball Bonders Bonder software version x-xx-x-472-series ECID (U2) 1175 1176 1177 1178 1179 1180 1181 1182 1186 1187 1188 1189 1190 1191 1192 1193 1194 1195 1196 1197 1198 IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Equipment Constants Name Type Description EC_AllowLoadPPW OMHS EC_LoadPPWithTe mperature EC_PBIBondsWith LowScore EC_LoadPPWithInd exEyePoint EC_InhibitAutoRun WithoutConv EC_Save_Real_Ti me_3rd_Opt_Image s_State EC_Save_Real_Ti me_3rd_Opt_Image s_Format EC_Keep_Real_Ti me_3rd_Opt_Image s_After_Upload EC_Reteach_DIE_ EP_Pos_Limit_Tol_ X EC_Reteach_DIE_ EP_Pos_Limit_Tol_ Y EC_Reteach_LEAD _EP_Pos_Limit_Tol _X EC_Reteach_LEAD _EP_Pos_Limit_Tol _Y EC_Reteach_SUB_ EP_Pos_Limit_Tol_ X EC_Reteach_SUB_ EP_Pos_Limit_Tol_ Y EC_USG_LF_Engr _Current_Offset EC_USG_HF_Engr _Current_Offset EC_USG_LF_Curre nt_Factor EC_USG_HF_Curr ent_Factor EC_USG_LF_Mach ine_Current_Offset EC_USG_HF_Mac hine_Current_Offse t EC_UsgImpedance LHLimit U1[1] Allow Load PP Without MHS U1[1] Load PP with temperature U1[1] PBI bonds with low score control option U1[1] Load PP with index eye point settings U1[1] Inhibit auto run without auto minor conversion BL[1] Real Time 3rd Opt Images Save State U1[1] Real Time 3rd Opt Images Save Format BL[1] EC_Keep_Real_Time_3rd_Opt_Images_After_Upload F4[1] Position limit tolerance of x coordinator during die eye point reteach F4[1] Position limit tolerance of y coordinator during die eye point reteach F4[1] Position limit tolerance of x coordinator during lead eye point reteach F4[1] Position limit tolerance of y coordinator during lead eye point reteach F4[1] Position limit tolerance of x coordinator during substrate eye point reteach F4[1] Position limit tolerance of y coordinator during substrate eye point reteach F4[1] Low USG Engineer voltage offset F4[1] High USG Engineer voltage offset F4[1] USG Low Frequency Current Factor F4[1] USG High Frequency Current Factor F4[1] USG Low Frequency voltage offset F4[1] USG High Frequency voltage offset U2[1] USG impedance low frequency high limit. Page - 156 - of 321 Sep 18, 2020 Rev 4.1 Kulicke & Soffa™ SECS/GEM Interface for K&S Ball Bonders Bonder software version x-xx-x-472-series ECID (U2) 1199 IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Equipment Constants Name Type Description U1[1] USG impedance low frequency low limit. 1200 EC_UsgImpedance LLLimit Using HSMS I4[1] 1201 1202 1203 1204 1205 1206 1207 1208 1211 T1 T2 T3 T4 T5 T6 T7 T8 BaudRate I4[1] I4[1] I4[1] I4[1] I4[1] I4[1] I4[1] I4[1] I4[1] 1212 1213 RetryLimit ConnectWait I4[1] I4[1] 1214 DetectDuplicate I4[1] 1215 ActiveMode I4[1] 1216 RemoteAddress A[40] 1217 RemotePort I4[1] 1218 LocalPort I4[1] 1219 CommPort A[40] 1220 Machine IP Address A[15] 1221 GatewayInet A[15] 1222 TargetName A[19] 1223 1224 1225 1226 HostName HostIP SubnetMask KgemBtnPwd A[19] A[15] A[15] A[12] Flag used to indicate that HSMS will be used by equipment for SECS2 communications. Host read-only. When changed by operator, requires equipment to be rebooted to take effect. FALSE = use SECS 1 TRUE = use HSMS SECS-I Inter-Character Timeout(see section 5) SECS-I Protocol Timeout(see section 5) SECS-I/HSMS Reply Timeout(see section 5) SECS-I Inter-Block Timeout(see section 5) HSMS Connect Separation Timeout(see section 5) HSMS Control Transaction Timeout(see section 5) HSMS Not Selected Timeout(see section 5) HSMS Network Inter-Character Timeout(see section 5) SECS-I serial line speed. Host read-only. When changed by operator, requires equipment to be rebooted to take effect. SECS-I retry limit. Number of seconds equipment’s HSMS should wait to establish a TCP/IP connection. Flag used to indicate if SECS1 should check for duplicate blocks when receiving multi-block messages. HSMS Connect Mode. Host read-only. When changed by operator, requires equipment to be rebooted to take effect. IP address or IP host name of Host. Host read-only. When changed by operator, requires equipment to be rebooted to take effect. TCP/IP Port used by host. Host read-only. When changed by operator, requires equipment to be rebooted to take effect. TCP/IP port used by equipment. Host read-only. When changed by operator, requires equipment to be rebooted to take effect. Name of equipment’s serial device. Host read-only. When changed by operator, requires equipment to be rebooted to take effect. IP Address used by equipment. Host read-only. When changed by operator, requires equipment to be rebooted to take effect. The internet address of the gateway through which to boot, if the host is not on the same network as the target(gateway inet(g) in Bootline). When changed by the operator, requires equipment to be rebooted to take effect. Target name (tn) in BootLine. This the bonder's host name. When changed by the operator, requires equipment to be rebooted to take effect. The name of the host to boot from. The Internet address of the host to boot from. Mask used to correctly access the host Password for accessing the Communication and Control State dialogs. Page - 157 - of 321 Sep 18, 2020 Rev 4.1 Kulicke & Soffa™ SECS/GEM Interface for K&S Ball Bonders Bonder software version x-xx-x-472-series ECID (U2) 1227 IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Equipment Constants Name Type Description LoadDefBootParms BL[1] EC_EnablePrimary BondParm EC_AutoUnclamp BL[1] EC_RegripLeadfra me EC_RehomeZ EC_PowerFailReco very EC_PFRInterval EC_MotionAfterYS ensorSetup BL[1] When set to TRUE, factory default settings for host name, machine IP address, host IP, gateway IP address, and target name. Note: The equipment constant is always set to FALSE every time the Modify Equipment Constant dialog is displayed. Enable/Disable the primary bond parameter update. (0 = OFF, 1 = ON) Setting for auto unclamp mode 0=OFF/1=AutoStateOnly/2=Auto&IdleState Turn the Regrip Leadframe ON/Off BL[1] BL[1] Turn on/off the Rehome Z magazine Power fail recovery mode U2[1] BL[1] BL[1] F4[1] U1[1] Request PP List from host has timed out BL[1] Auto Correct Ref.Sys Xhair Delta Feature Enabled/Disabled U1[1] U4[1] 1332 EC_GUI_PP_Prote ct EC_Auto_Unclamp _Timeout Req_PP_List_Time out EC_AutoCorrectRef SysXhairDelta EC_NegYPullOffset ProdReportThresho ld EC_AutoClearFAD ataOnPage1 EC_AutoClearFAD ataOnPage2 EC_AutoClearFAD ataOnPage3 UserEC1 Power fail recovery interval(minutes). Calibrated / Manual option. 255 = Calibrated, 0 = Manual Control permission to overwrite existing Long and / or Short Program Filenames when using the bonder GUI. ECO Auto Unclamp time 1333 UserEC2 A[15] 1334 UserEC3 A[15] 1377 EC_UserEC23 BL[1] 1378 EC_UserEC24 BL[1] 1379 EC_UserEC25 BL[1] Magazine y direction configuration, normal(0) or reverse(1). Number of packages to be processed before PACKAGE_THRESHOLD-REACHED collection event is sent. Constant to show if “auto clear FA Data After Sent” feature for page of operator manual data Entry #1 is enabled or disabled. Constant to show if “auto clear FA Data After Sent” feature for page of operator manual data Entry #2 is enabled or disabled. Constant to show if “auto clear FA Data After Sent” feature for page of operator manual data Entry #3 is enabled or disabled. Operator Entry #1 dialog - 1st item string label. Default = "Enter_Data_A" Operator Entry #1 dialog - 2nd item string label. Default = "Enter_Data_B" Operator Entry #1 dialog - 3rd item string label. Default = "Enter_Operator_" Set the lock state of panel 1 on “Operator Data Entry #2” dialog FALSE: unlock the data entry TRUE: lock the data entry Set the lock state of panel 2 on “Operator Data Entry #2” dialog FALSE: unlock the data entry TRUE: lock the data entry Set the lock state of panel 3 on “Operator Data Entry #2” dialog FALSE: unlock the data entry TRUE: lock the data entry 1239 1240 1241 1242 1243 1244 1245 1246 1247 1248 1250 1255 1300 1329 1330 1331 U1[1] BL[1] BL[1] BL[1] A[15] Page - 158 - of 321 Sep 18, 2020 Rev 4.1 Kulicke & Soffa™ SECS/GEM Interface for K&S Ball Bonders Bonder software version x-xx-x-472-series ECID (U2) 1380 IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Equipment Constants Name Type Description EC_UserEC26 BL[1] 1381 1382 1383 1384 1385 1386 1387 1388 1389 1390 1391 EC_UserEC13 EC_UserEC14 EC_UserEC15 EC_UserEC16 EC_UserEC17 EC_UserEC18 EC_UserEC19 EC_UserEC20 EC_UserEC21 EC_UserEC22 UserEC5 A[15] A[15] A[15] A[15] A[15] A[15] A[15] A[15] A[15] A[15] A[15] 1392 UserEC6 A[15] 1393 UserEC7 A[15] 1394 UserEC8 A[15] 1395 U1[1] 1398 EC_BITsAutoRecv Shtl EC_BITsAutoRecv EFO EC_FalseNSOP 1399 EC_TimeFormat U1[1] 1401 EC_PreclampExpa nsionOption U1[1] 1402 EC_PreclampExpa nsionTime EC_MagEjectOpt U4[1] EC_CAP_CLEAN_ ENABLE EC_CAP_CLEAN_ KWIRE EC_CAP_CLEAN_ TOUCHDOWN EC_TIP_For_CapCl eaning EC_CV_For_CapCl eaning EC_USG_Current_ For_CapCleaning BL[1] 1396 1403 1404 1405 1406 1407 1408 1409 U1[1] U1[1] BL[1] U2[1] Set the lock state of panel 4 on “Operator Data Entry #2” dialog FALSE: unlock the data entry TRUE: lock the data entry Operator Entry #3 dialog - 1th item string label. Operator Entry #3 dialog - 2th item string label. Operator Entry #3 dialog - 3th item string label. Operator Entry #3 dialog - 4th item string label. Operator Entry #3 dialog - 5th item string label. Operator Entry #3 dialog - 6th item string label. Operator Entry #3 dialog - 7th item string label. Operator Entry #3 dialog - 8th item string label. Operator Entry #3 dialog - 9th item string label. Operator Entry #3 dialog - 10th item string label. Operator Entry #2 dialog - 1st item string label. Default = "Enter_SV_3901" Operator Entry #2 dialog - 2nd item string label. Default = "Enter_SV_3092" Operator Entry #2 dialog - 3rd item string label. Default = "Enter_SV_3093" Operator Entry #2 dialog - 4th item string label. Default = "Enter_SV_3094" BITS Dialog setting on auto recovery for Short Tail 0=OFF/1=ON BITS Dialog setting on auto recovery for EFO 0=OFF/1=ON Flag to turn on/off Backup for BITS NSOP 0=OFF/1=NSOP ON BALL/2=NSOP ON BUMP System Time Format: 0 = 12 bytes: YYMMDDHHMMSS 1 = 16 bytes: YYYYMMDDHHMMSSCC Expansion Compensation state:Preclamp expansion option 0 = OFF 1 = FIRST INDEX 2 = ALL INDEX Preclamp expansion time Enable/Disable “Eject Mag after Every PP Change”. (0 = OFF., 1 = ON) Cap cleaning enable/disable(=0/1) F4[1] Number of wires to be bonded before cap cleaning sequence is triggered (x1000) Number of cap touchdowns on the tape for each cap cleaning sequence Tip value for cap cleaning (same meaning as Bond parameter) F4[1] C/V value for cap cleaning (same meaning as Bond parameter) F4[1] USG current for cap cleaning (same meaning as Bond parameter) U2[1] Page - 159 - of 321 Sep 18, 2020 Rev 4.1 Kulicke & Soffa™ SECS/GEM Interface for K&S Ball Bonders Bonder software version x-xx-x-472-series ECID (U2) 1410 IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Equipment Constants Name Type Description EC_USG_Time_Fo r_CapCleaning EC_Bond_Force_F or_CapCleaning EC_Contact_Thres hold_For_CapClea ning EC_USG_Prebleed _For_CapCleaning EC_PM_TimeForm at F4[1] USG time for cap cleaning (same meaning as Bond parameter) F4[1] Bond force for cap cleaning (same meaning as Bond parameter) U1[1] Contact threshold for cap cleaning (same meaning as Bond parameter) U1[1] BL[1] U1[1] VLL foreign material detection area tolerance. 1417 EC_PM_VLLFMDE TECTED EC_PM_VLLFMAR EATOL EC_LTO_Green USG Pre-bleed for cap cleaning (same meaning as Bond parameter) Define production monitoring (PM) time format. 0 = : Support yyyymmddhhmmss (14 characters). 1 = : Support yyyymmddhhmmsscc (16 characters). It takes effect after machine reboot. VLL foreign material detection setting for MTBA calculation. U1[1] 1418 EC_LTO_Yellow U1[1] 1419 EC_LTO_Red U1[1] 1420 1421 1422 EC_Pusher_Kit CfgAuto_Eye_Pts CfgAuto_Contact_S urface CfgAuto_VLL CfgAuto_VLL_Asso c CfgAuto_Backup_E ye_Pts CfgAuto_Indexing CfgAuto_EFO CfgAuto_Operator_ Pts CfgAuto_Temp_Ala rm CfgAuto_Alarm_Co nfig CfgAuto_Temp_Err or CfgAuto_VLL_Tip_ Find Auto_Run_Mode BL[1] BL[1] BL[1] Green light tower settings 0=off/1=on/2=flash Yellow light tower settings 0=off/1=on/2=flash Red light tower settings 0=off/1=on/2=flash Pusher Kit configuration Eye Points Contact_Surface surface BL[1] BL[1] VLL surface setting on Dry cycle VLL_Assoc surface setting on Dry cycle U1[1] Backup_Eye Points U1[1] BL[1] BL[1] Indexing 0/Normal 1/Manual 2/Dry 3/Skip EFO 0=off /1=on Operator Points 0=off /1=on BL[1] Temperature Alarm 0=off /1=on BL[1] Temp_ Alarm_ Config 0=off /1=on BL[1] Delayed Temp_ Error 0=off /1=on BL[1] VLL_ Tip_ Find 0=off /1=on BL[1] EC_GEMButtonsEn abled EC_OfflineTimeBef oreInhibitAuto EC_ProcessErrors EC_VisionErrors BL[1] Run Mode: 0/Dry Cycle 1/Auto Run GEM buttons configuration. U2[1] Offline time (in seconds) before inhibit auto. U4[1] U4[1] Process errors Vision errors 1411 1412 1413 1414 1415 1416 1423 1424 1425 1426 1427 1428 1429 1430 1431 1432 1433 1434 1435 1436 1437 U1[1] Page - 160 - of 321 Sep 18, 2020 Rev 4.1 Kulicke & Soffa™ SECS/GEM Interface for K&S Ball Bonders Bonder software version x-xx-x-472-series ECID (U2) 1438 1439 IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Equipment Constants Name Type Description EC_MaterialErrors EC_WorkholderErr ors EC_MaghandlerErr ors CfgRun_BITS CfgRun_Wire_Feed _Error CfgRun_VLL CfgRun_VLL_Asso c CfgRun_Backup_E ye_Pts CfgRun_Indexing CfgRun_Temp_Alar m_Config CfgRun_Delayed_T emp_Error CfgRun_VLL_Tip_F ind EC_VLL_Delay EC_Prs_Die_Delay EC_Prs_Lead_Dela y EC_Backup_PRS_ NSOP EC_NSOPNotify EC_NSOLNotify EC_SHTLNotify EC_PRSNSOPWire AngleCheck EC_TOOL_VALIDA TION U4[1] U4[1] Material errors Work holder errors U4[1] Magazine handler errors. BL[1] BL[1] BITS setting on Auto Run Wire_ Feed_ Error on Auto Run Configuration Dialog. BL[1] BL[1] VLL on Auto Run Configuration Dialog. VLL Association on Auto Run Configuration Dialog. U1[1] Backup_ Eye Points on Auto Run Configuration Dialog. BL[1] BL[1] Indexing 0/Normal 1/Manual on Auto Run Configuration Dialog. Temp_Alarm_Config setting on Auto Run BL[1] Delayed_Temp_Error setting on Auto Run BL[1] VLL_ Tip_ Find on Auto Run Configuration Dialog. F4[1] F4[1] F4[1] VLL Delay PRS Delay for Die Eye Point PRS Delay for Lead Eye Point U4[1] Backup PRS NSOP BITS error auto recovery BL[1] BL[1] BL[1] U1[1] BITS Configuration: NSOP Notify 0=off /1=on BITS Configuration: NSOL Notify 0=off /1=on BITS Configuration: SHTL Notify 0=off /1=on Change in PRS NSOP Wire Angle Check U1[1] 1461 EC_WIRE_VALIDA TION U1[1] 1462 EC_DFLT_PART_I D EC_LTO_White EC_LTO_Blue EC_USGCleanVolt EC_USGFreqSelec tion EC_ForceBondHtR elrn EC_MinWireThresh old EC_WireUsageTim er EC_TimerDuration A[80] Tool validation enables flag 0 = disable 1 = enable Wire validation enables flag 0 = disable 1 = enable Default part Id U1[1] U1[1] U2[1] U1[1] White light tower settings 0=off/1=on/2=flash Blue light tower settings 0=off/1=on/2=flash USG clean voltage USG high and low frequency selection U1[1] Force bond height to relearn if enable F4[1] U1[1] Wire spool should be changed if remaining wire length less than min wire threshold Turn on/off wire usage with timer U2[1] Time duration for change wire spool 1440 1441 1442 1443 1444 1445 1446 1449 1450 1451 1452 1453 1454 1455 1456 1457 1458 1459 1460 1470 1471 1481 1482 1483 1484 1485 1486 Page - 161 - of 321 Sep 18, 2020 Rev 4.1 Kulicke & Soffa™ SECS/GEM Interface for K&S Ball Bonders Bonder software version x-xx-x-472-series ECID (U2) 1487 1488 1489 1490 1491 1492 1500 1501 1502 1503 1504 1505 1506 1507 1508 1509 1510 1511 1512 1513 1514 1515 1516 1517 1518 1519 1520 1521 1522 IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Equipment Constants Name Type Description EC_StopBondingAft er EC_WireUsageInfo MinSample EC_WireUsageDisp lay EC_WireSpoolDiam eter EC_InitialBondCou nt EC_InitialHoursInU se PM Data Update Mode PM_StartTime PM_StopTime EC_Lot_StartTime EC_PM_StartTime EC_PM_EndTime EC_PreclampExpa nsionClamp EC_PreclampHBOff set EC_ToolPNInfo EC_WirePNInfo EC_FalseNSOL EC_LOT_CONTRO L_TRACKING EC_WireUsageUnit EC_ConnInhibitAut oOption U1[1] When wire expired, stop at finish device, index, or strip U1[1] U1[1] Min sample index bonded, then can display wire usage information Switch to show wire usage, OFF/Wire Remaining/ Wire Used F4[1] Wire spool diameter U4[1] Initial bond count when start bond U4[1] Initial used hours when start bond U1[1] I4[1] Update PM SV data Mode 0 = HOST RCMD 1 = Bonder GUI Start time for logged data analysis, format yyyymmddhhmmss. Stop time for logged data analysis, format yyyymmddhhmmss. Lot Start Time. The Start Time of PM data summary in bonder side The End Time of PM data summary in bonder side Preclamp expansion clamp 0=OPEN/1= CLOSE Preclamp HB Offset A[33] A[33] BL[1] BL[1] Capillary Serial or Part number Wire Serial or Part number Flag to turn on/off Backup for BITS NSOL. (0 = OFF, 1 = ON) Flag to turn on/off Lot Control Tracking. (0 = OFF, 1 = ON) U4[1] U2[1] EC_Map_Column_ Compacted CfgMagID_IMH_St ate CfgMagID_IMH_Fai lOP CfgMagID_IMH_De faultBcr CfgMagID_IMH_Val idOp CfgMagID_IMH_Re try CfgMagID_OMH_St ate CfgMagID_OMH_F ailOP CfgMagID_OMH_D efaultBcr BL[1] Wire Usage Unit configuration. (0=DEVICE/1=INDEX) Option for Connectivity Inhibit Auto option (Read Only): Bit 1 = Comm Down. Bit 2 = Control Offline. Bit 3 = Control Local. Flag to turn on/off strip map column compact mode. (0 = OFF, 1 = ON) Configure Mag ID Input Mag Handler State A[14] A[14] A[14] A[14] A[14] U1[1] BL[1] U1[1] A[80] Configure Mag ID Input Mag Handler OP (0=ASK /1=Eject /2=Eject and Stop / 3= Send Default Mag ID) Configure Mag ID Input Mag Handler Default BCR BL[1] Configure Mag ID Input Mag Handler Valid OP U1[1] Configure Mag ID Input Mag Handler Retry (0= 0 times /1= 1 times /2= 2 times /3= 3 times) Configure Mag ID Output Mag Handler State BL[1] U1[1] A[80] Configure Mag ID Output Mag Handler Fail OP (0=ASK /1=Eject /2=Eject and Stop / 3= Send Default Mag ID) Configure Mag ID Output Mag Handler Default BCR Page - 162 - of 321 Sep 18, 2020 Rev 4.1 Kulicke & Soffa™ SECS/GEM Interface for K&S Ball Bonders Bonder software version x-xx-x-472-series ECID (U2) 1523 1524 1525 1526 1527 1528 1529 1530 1531 1532 1533 1534 1535 1536 1537 1538 1540 1550 1551 1552 1553 1554 IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Equipment Constants Name Type Description CfgMagID_OMH_V alidOp CfgMagID_OMH_R etry OhtCtrlStatus BL[1] Configure Mag ID Output Mag Handler Valid OP U1[1] EC_OHT_Load_Ma g_Benching_Kit_Ac tion EC_ARVState B[1] EC_ImhSlotScanSt ate EC_OmhSlotScanS tate EC_LoadPPNoInfo Dialog EC_UsgImpedance DeltaCheck EC_UsgImpedance LDeltaForManualC alibration EC_UsgImpedance HDeltaForManualC alibration EC_UsgImpedance LDeltaForPeriodicS can EC_UsgImpedance HDeltaForPeriodicS can EC_PreclampSeco ndPrsCorrOption EC_OutSlotLFDete ctKitInstalled EC_OutSlotLFDete ctEnabled EC_GEMMessage CollectionEnabled EC_SubReaderEna ble EC_SubIDValidatio n EC_GLOBAL_ID_V ALIDATION_SWIT CH_CHANGED EC_ID_VALIDATIO N_OFF_AT_COMM DOWN EC_ID_VALIDATIO N_OFF_AT_CTRL_ OFFLINE BL[1] BL[1] Configure Mag ID Output Mag Handler Retry (0= 0 times /1= 1 times /2= 2 times /3= 3 times) OHT control Status (TURE:OHT FALSE: STANDALONE) Determine the benching kit action after OHT loads mag onto loading tray. 0 means no action. 1 means that benching kit extends and holds there after mag being loaded by OHT. ARV state (TRUE = enable; FALSE=disable) True – Input mag slot scanning is enabled. False – Input mag slot scanning is disabled True – Output mag slot scanning is enabled. False – Output mag slot scanning is disabled Load PP Ignore Info Dialog BL[1] USG Impedance Delta Check F4[1] USG Impedance Low Delta For Manual Cal F4[1] USG Impedance High Delta For Manual Cal F4[1] USG Impedance Low Delta for Perioidc Scan F4[1] USG Impedance High Delta for Perioidc Scan U1[1] PreClamp Sencond PRS Correction Option BL[1] Constant to show if “out slot LF detection kit” is installed or not . BL[1] Constant to show if the “out slot LF detection” feature is enabled BL[1] GEM Log Msg Collection Enable/Disable BL[1] Substrate reader enables flag BL[1] Substrate reader validation enables flag BL[1] Global ID host validation switch changed BL[1] Set ID Validation switch when bonder in COMM-DOWN mode BL[1] Set ID Validation switch when bonder in CTRL-Offline mode BL[1] BL[1] BL[1] Page - 163 - of 321 Sep 18, 2020 Rev 4.1 Kulicke & Soffa™ SECS/GEM Interface for K&S Ball Bonders Bonder software version x-xx-x-472-series ECID (U2) 1555 1556 1557 1558 1559 1560 1561 1562 1563 1564 1565 1566 1567 1568 1569 1570 1571 1572 1573 1574 1575 1576 1577 1578 IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Equipment Constants Name Type Description EC_ID_VALIDATIO N_OFF_AT_CTRL_ LOCAL EC_Input_Mag_Vali dation_Reject_Opti on EC_Input_Mag_Vali dation_Timeout EC_Output_Mag_V alidation_Reject_O ption EC_Output_Mag_V alidation_Timeout EC_Substrate_Vali dation_Reject_Opti on EC_Substrate_Vali dation_Timeout EC_Dummy_State Remote Selected Log File EC_StripMap_Dwnl d_Src StripMap_State StripMap_Downloa d_Mode Output_CellStatus_ OutputGoodDev Output_CellStatus_ InputDefectDev Output_CellStatus_ RejectedDev Output_CellStatus_ NotBondedDev CellGrade_Mode StripID_From_2D_ State 2D_Code_Reader_ State 2D_Force_Read_St ate BackupSubIDSearc h EC_Desirable_Strip Map_Setting EC_Cpu-And-OsFault-MonitorInterval EC_Cpu-And-OsFault-MonitorEnable BL[1] Set ID Validation switch when bonder in CTRL-Local mode U1[1] Input Magazine On Validation Reject Option /0= error /1= stop U1[1] Input Magazine validation timeout U1[1] Output Magazine On Validation Reject Option /0= error /1= stop U1[1] Output Magazine validation timeout U1[1] Substrate validation Reject Option /0= error /1= stop U1[1] Substrate validation Timeout U1[1] A[81] BL[1] U1[1] Dummy State Setting Used to indicate which log file is selected for the log file transferring via S13F3-S13F8. The source of input strip map: 0=Machine/1=Host Strip Map On/Off Setting Strip Map Download Mode U1[1] Output Cell Status of output Good Device U1[1] Output Cell Status of Input Defect Device U1[1] Output Cell Status of Rejected Device U1[1] Output Cell Status of Not Bonded Device U1[1] BL[1] Cell Grade Mode Get Strip ID From 2D BL[1] 2D Code Reader State BL[1] 2D Force Read State U1[1] Backup substrate ID search type U1[1] Desirable Strip Map Setting I4[1] Interval to monitor for CPU and System Fault (in Seconds) BL[1] Flag to enable the monitoring for CPU and System Fault (in Seconds U1[1] Page - 164 - of 321 Sep 18, 2020 Rev 4.1 Kulicke & Soffa™ SECS/GEM Interface for K&S Ball Bonders Bonder software version x-xx-x-472-series ECID (U2) 1579 1580 1581 1582 1583 1584 1585 1586 1587 1588 1589 1590 1591 1592 1593 1594 1595 1596 1597 1600 1601 1602 1603 1604 1605 1606 IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Equipment Constants Name Type Description EC_StripMap_Unde sired _Setting_Inhibit_Au to OHT_Insp_Mode_S tatus OHT_Input_Load_T imeout OHT_Input_Unload _Timeout OHT_Output_Load _Timeout OHT_Output_Unloa d_Timeout EC_OHT_Load_Tra y_Benching EC_OHT_Unoad_T ray_Belting EC_IndexEyeExten dSearch EC_SKIP_BITS_LE ARN_PROMPT EC_CM_Log_State EC_StripMapLoadF rom EC_StripMapPPDef ault EC_MAP_DOWNL OAD_ORIENTATIO N EC_MAP_UPLOAD _ORIENTATION EC_InputStripMapC ells EC_InputCellGrade OnAssist EC_UnknownDevCt lOption EC_CellGradeForm at EC_INPUT_BARC ODE_READER EC_OUTPUT_BAR CODE_READER EC_2D_CODE_RE ADER EC_EFOPMEnable EC_EFOCleaningIn terval EC_CmLogInterval EC_StripIDReadLo adFrom U1[1] When enable Undesired Setting Inhibit Auto, it will inhibit auto bonding if strip map configuration doesn't match the desire.Default is Disabled. BL[1] OHT Insp Mode Status U2[1] OHT input loading timeout delay U2[1] OHT input unloading timeout delay U2[1] OHT output loading timeout delay U2[1] OHT output unloading timeout delay BL[1] OHT loading tray benching option BL[1] OHT output mag unload tray belting config BL[1] State of extend search of index eye point U1[1] Control of prompt of BITS Learn related BL[1] U1[1] Control of common log file function Configure where to load Strip Map configuration U1[1] Default Strip Map setting for PP U2[1] Change the download map orientation U2[1] Change the upload map orientation U1[1] Input strip map data BL Input Cell Grade On Assist BL Unknown Device control option U1[1] Cell grade format A[30] Input Barcode Reader A[30] Output Barcode Reader A[30] 2D Code Reader U4[1] U4[1] EFO Preventive Maintenance enable EFO Cleaning Interval U4[1] U1[1] Interval for common log file saving Configure where to load strip ID read state setting, MDP or PP Page - 165 - of 321 Sep 18, 2020 Rev 4.1 Kulicke & Soffa™ SECS/GEM Interface for K&S Ball Bonders Bonder software version x-xx-x-472-series ECID (U2) 1607 1612 1613 1614 1615 1616 1617 1618 1619 1620 1621 1622 1623 1708 IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Equipment Constants Name Type Description EC_StripIDReadPP Default EC_TempZone1Set Point EC_TempZone1Off set EC_TempZone1Tol erance EC_TempZone1On Off EC_TempZone2Set Point EC_TempZone2Off set EC_TempZone2Tol erance EC_TempZone2On Off EC_TempZone3Set Point EC_TempZone3Off set EC_TempZone3Tol erance EC_TempZone3On Off EC_PrivControlMod e U1[1] I2[1] Default strip ID read state setting for loading strip ID read from PP when no PP is loaded. Set temperature zone1 preheat setpoint value I2[1] Set temperature zone1 preheat offset value I2[1] Set temperature zone1 preheat tolerance value U1[1] Turn temperature zone1 preheat on/off I2[1] Set temperature zone2 bondsite setpoint value I2[1] Set temperature zone2 bondsite offset value I2[1] Set temperature zone2 bondsite tolerance value U1[1] Turn temperature zone2 bondsite on/off I2[1] Set temperature zone3 postheat setpoint value I2[1] Set temperature zone3 postheat offset value I2[1] Set temperature zone3 postheat tolerance value U1[1] Turn temperature zone3 postheat on/off U1[1] Set/Get Privilege Password Control Setting. 0: Access Level 1: User Identification LHM enable (F=Off, T=On) Target Loop ID for associated GEM operations 1749 EC_LHM_STATE BL[1] 1751 EC_LHM_GEM_LO OP_ID EC_LHM_GEM_M EASURE_TYPE EC_LHM_LIMIT_M ETHOD EC_LHM_ERROR_ LIMIT_ACTIVE U1[1] EC_LHM_ERROR_ UPPER_LIMIT EC_LHM_ERROR_ LOWER_LIMIT EC_LHM_RESULT _VALIDATION_ST ATE EC_LHM_RESULT _VALIDATION_RE JECT_OPTION F4[1] Target Measurement Type for associated GEM operations (0=Max Loop Height, 1=Edge Height Limit Method to use for targeted Loop ID and Limit Type (0=Off, 1=User Defined) Error limit control of targeted Loop ID and Limit Type (0=Off, 1=Both, 2=Upper Only, 3=Lower Only) Upper error limit of targeted Loop ID and Limit Type F4[1] Lower error limit of targeted Loop ID and Limit Type BL[1] Measurement result validation enable U1[1] Measurement result validation Reject Option (0=Error, 1=Stop) 1753 1754 1758 1759 1760 1761 1762 U1[1] U1[1] U1[1] Page - 166 - of 321 Sep 18, 2020 Rev 4.1 Kulicke & Soffa™ SECS/GEM Interface for K&S Ball Bonders Bonder software version x-xx-x-472-series ECID (U2) 1763 1764 1765 1770 1771 1780 1781 1782 1783 1784 1785 1786 1787 1788 1789 1790 1791 1792 1793 1794 1795 1796 1797 1798 IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Equipment Constants Name Type Description EC_LHM_MAX_LO OP_HEIGHT_MEA S_CODE EC_LHM_EDGE_H EIGHT_MEAS_CO DE EC_LHM_LIMIT_C ONTROL_TYPE EC_LHM_SAMPLI NG_UNIT EC_LHM_SAMPLI NG_INTERVAL EC_WireInspState A[20] Code for maximum loop height measurement A[20] Code for edge height measurement U1[1] U1[1] Limit Type to use for targeted Loop ID (0=Absolute, 1=Relative) LHM sampling unit (0=Index, 1=Strip, 2=Mag) U4[1] LHM sample every N units BL[1] EC_WireInspBrkPnt sEnabled EC_WireInspAssoc State EC_WireInspRealig nState EC_ReqMeasurePe rWireInsp EC_TriesPerWireIn spMax EC_WireInspFailSt opMode EC_WireInspPeriod icSamplingState EC_WireInspSampl ingIntervalUnit EC_WireInspSampl ingInterval EC_WireInspTrigge rOnToolChangeStat e EC_WireInspTrigge rOnWireSpoolChan geState EC_WireInspTrigge rOnStartAutoRunSt ate EC_KgemWireInspI d EC_WireInspLimitM ethod EC_WireInspErrorLi mitUpperState EC_WireInspErrorLi mitUpper EC_WireInspWarnL imitUpperState EC_WireInspWarnL imitUpper BL[1] Wire Inspection: Enabled state Wire Inspection: Breakpoint enabled state Wire Inspection: Association enabled state Wire Inspection: Realign before inspection enabled state Wire Inspection: Required measurement per wire inspection (value >= 1) Wire Inspection: Maximum tries per wire (value >= 1) Wire Inspection: Fail stop mode Wire Inspection: Periodic sampling state Wire Inspection: Sampling interval unit. 0- Device, 1-Index Wire Inspection: Sampling interval number Wire Inspection: Trigger on tool change state BL[1] BL[1] U1[1] U1[1] B[1] BL[1] B[1] U2[1] BL[1] BL[1] Wire Inspection: Trigger on wire spool change state BL[1] Wire Inspection: Trigger on start auto run state U1[1] Wire Inspection: Wire inspection ID Wire Inspection: Limit method, 0-Off, 1-User Define Wire Inspection: Error limit upper state Wire Inspection: Error limit upper value Wire Inspection: Warn limit upper state Wire Inspection: Warn limit upper value B[1] BL[1] F4[1] BL[1] F4[1] Page - 167 - of 321 Sep 18, 2020 Rev 4.1 Kulicke & Soffa™ SECS/GEM Interface for K&S Ball Bonders Bonder software version x-xx-x-472-series ECID (U2) 1822 IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Equipment Constants Name Type Description UserEC4 A[30] 1891 UserEC9 A[30] 1892 UserEC10 A[30] 1893 UserEC11 A[30] 1894 UserEC12 A[30] Operator Entry #1 dialog - 4th item Default = "Send_Operator_Event" Operator Entry #2 dialog - 5th item Default = "Send_CE_8091" Operator Entry #2 dialog - 6th item Default = "Send_CE_8092" Operator Entry #2 dialog - 7th item Default = "Send_CE_8093" Operator Entry #2 dialog - 8th item Default = "Send_CE_8094" string label. string label. string label. string label. string label. Figure 59 – K&S Model Power Series Automatic Ball Bonder and K&S Model Gen-S Automatic Ball Bonder Shared Equipment Constants Page - 168 - of 321 Sep 18, 2020 Rev 4.1 Kulicke & Soffa™ SECS/GEM Interface for K&S Ball Bonders Bonder software version x-xx-x-472-series 6.4 K&S Model Power Series Automatic Ball Bonder and K&S Model Gen-S Automatic Ball Bonder Shared Collection Events The Collection Events (CEs) and associated Collection Event IDs (CEID) shared by K&S Model Power Series Automatic Ball Bonder and K&S Model Gen-S Automatic Ball Bonder are described in this section. Page - 169 - of 321 Sep 18, 2020 Rev 4.1 Kulicke & Soffa™ SECS/GEM Interface for K&S Ball Bonders Bonder software version x-xx-x-472-series IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Collection Events CEID Name Description 8001 Control State Changed to Online-Local WB transitions to the Online-Local control state. See the "WB communication/control state transition diagram". Recommend that a RPTID containing the SV's "ControlState" and "PreviousControlState" be linked to this event. 8002 Control State Changed to Online-Remote WB transitions to the Online-Remote control state. See the "WB communication/control state transition diagram". Recommend that a RPTID containing the SV's "ControlState" and "PreviousControlState" be linked to this event. 8003 Control State Changed to Offline WB transitions to an Offline control state. See the "WB communication/control state transition diagram". Recommend that a RPTID containing the SV's "ControlState" and "PreviousControlState" be linked to this event. 8004 Process State Change WB transitions between any process state. Recommend that a RPTID containing the SV's "ProcessState" and "PreviousProcessState" be linked to this event. 8006 SpoolingDeactivated WB has emptied spool and has no more messages to transmit. 8007 SpoolingActivated WB has begun spooling due to a communications failure. 8008 SpoolingXmitFail WB has detected a communication failure while transmitting spooled data to the host. Unloading of spooled data has ceased. 8010 TerminalMsgAck Operator has read and acknowledged a terminal message. 8011 Operator EC Change Operator has modified an equipment constant. Recommend that a RPTID containing the DVVAL 8012 New Output Magazine Required WB Output Side ready for new (empty) output mag 8013 Process Monitoring Data Ready Data generated in response to the host-initiated remote command CALC_PM_DATA is ready. 8014 Process Program Change Operator has modified a process program. 8015 CE_SAFETY_KIT_SNS_CH ANGED Safety kit sensor status changed 8016 CE_FOCUS_ADJ_CONFIG_ CHANGED Whenever there is change in focus adjustment configuration parameters. 8017 CE_PRIV_USER_DB_UPDA TE_SUCCESS Notify host password database update successfully 8018 CE_PRIV_USER_DB_UPDA TE_FAIL Notify host password database update fail 8020 Operation Mode Change Equipment operation mode has changed. Recommend that a RPTID containing a status variable "Equipment Mode" be linked to this event. 8021 Light Tower Status Change The light tower changed from one state to another. Recommend that a RPTID containing a status variable "Light Tower State" be linked to this event. (U2) Page - 170 - of 321 Sep 18, 2020 Rev 4.1 Kulicke & Soffa™ SECS/GEM Interface for K&S Ball Bonders Bonder software version x-xx-x-472-series IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Collection Events CEID Name Description 8022 Operator Data Entry This message is sent on command by the operator. Recommend that a RPTID containing the status variable "Operator Data A", "Operator Data B", and "Operator data ID" be linked to this event. 8023 CE_Clear_FA_Data Clear all data in an operator data dialog 8024 CE_Auto_Inhibited Auto is inhibited by host 8025 PBI-NOSTOP-ERR PBI:PBI No stop error 8028 CE_OPE_Mode_Change OPE mode or an activity in an OPE mode has changed. (U2) Note: This event is generated when an item in the main OPE dialog is selected, an intermediate sub-mode is displayed or when an ite in the lowest level sub-mode is selected. 8029 CE_Process_Start The equipment has started or resued execution of process program 8030 CE_Process_Stop Process program execution has ended. Equipment is no longer in Auto mode. 8031 AUTO-CHANGED-TOOL The equipment tool has been changed. 8032 CE_Process_Assist Process program execution has stopped due to alarms/execptions. At this point the equipment is still Auto mode waiting for the user to clear the alarms. Note:OPE host may use this event as the Outpu Stop signal from the equipment. 8033 CE_OPE_Tech_ID_Change The OPE Tech ID has been changed. This event is generated every time the OPE Tech ID dialog is closed. 8034 MHS_CARRIER_EJECTED This event is generated every time a leadframe is ejected into the output magazine. 8035 CE_Process_Pause This event is generated when the Run/Stop button is pressed during Auto Run mode to pause (Sequence Stop) process program execution. Note:OPE host may use this event as the Output Stop signal from the equipment. 8036 CE_RcmdStart_Aborted Remote command PROCESS_START has been aborted. 8037 UPDATE_ERROR_GROUP S Error group has been updated. 8038 UPDATE_MACHINE_STAT ES Machine state has been updated. 8039 Auto BITS Status Changed The global BITS state has been changed. The BITS state is manually changed in the Auto Run Configuration or BITS Configuration dialog. 8040 Changed Wire Spool Operator has changed the Wire Spool length. The event is triggered when the Change Wire Spool item of Wire Usage dialog is selected. Page - 171 - of 321 Sep 18, 2020 Rev 4.1 Kulicke & Soffa™ SECS/GEM Interface for K&S Ball Bonders Bonder software version x-xx-x-472-series IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Collection Events CEID Name Description 8041 CAL_USG_SUCCESSFUL USG calibration was performed. The event is triggered when the Accept item is selected from the USG Tune Results dialog. 8042 ASSIST_COMPLETE When the alarm type is configured to be ON/OFF, operator's selection from the main event handler dialog has been completed, i.e. continue, retry, abort, recover, or done. (U2) When the alarm type is configured to be “ASK”, the operator has selected a reason code. 8043 PBI_UNIT_INSPECT_COM PLETED PBI: Inspection of a unit has completed 8044 PBI_CONFIG_CHANGED PBI: Config has been changed. 8045 PBI_STATISTICS_RESET PBI: Statistics has been reset. 8046 CE_POWERSAVE_CONFIG _CHANGED Whenever there is change in a power save configuration parameters 8048 O_MAG_EJECT_THRESHO LD_WARNING_HEADER Output magazine eject threshold has been reached. 8049 CE_WireCtrl_Config_Chang ed The start/stop wire control parameters has been changed. 8050 CE_PROCESS_MON_DAT A_UPDATED PM status variable data 3500-3520 has been updated. 8051 CE_INCORRENT_PM_DAT A The PM data is incorrent 8052 CE_CM_LOG_READY Customized Log File is ready 8053 CE_CM_LOG_FAIL Fail to generate customized Log File 8054 CE_PART_MAP_DLOAD_A BORT Abort the part map download process 8060 EH_AUTO_SHTL_RECV_A TTEMPTED Triggered while Short tail recovery attempts 8061 EH_AUTO_SHTL_RECV_S UCCESS Triggered while Short tail recovery attempts success 8062 EH_AUTO_EFO_OPEN_RE CV_ATTEMPTED Triggered while EFO open recovery attempts 8063 EH_AUTO_EFO_OPEN_RE CV_SUCCESS Triggered while EFO open recovery success 8064 EH_VACUUM_ERROR_SKI PPED_REPORT CEID triggered when skip package for vacuum error 8065 CE_START_INDEX_DEVIC E CEID triggered when start index device to bondsite 8066 CE_OPE_STATE_CHANGE D OPE State Changed 8067 CE_Start_Process_Device CEID triggered when start to process device Page - 172 - of 321 Sep 18, 2020 Rev 4.1 Kulicke & Soffa™ SECS/GEM Interface for K&S Ball Bonders Bonder software version x-xx-x-472-series IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Collection Events CEID Name Description 8070 EH_AUTO_LHM_MEASURE _COMPLETED LHM: Measurement has completed 8080 CE_SUBSYSTEM_CONFIG _CHANGED Notify host when subsystem configuration changed. 8090 CE_UserDefinedSV_Change d UserDefinedSV Changed 8091 CE_User_Defined_CE1 A Customer-defined event to indicate the start of a lot. 8092 CE_User_Defined_CE2 A Customer-defined event to indicate the end of a lot. 8093 CE_User_Defined_CE3 A Customer-defined event to indicate the cancellation of a lot. 8094 CE_User_Defined_CE4 User Defined Event and event description 8100 PP Download Equipment has completed downloading the process program, whether successful or not. Recommend that a RPTID containing the SV’s "DownloadPPName" and "DownloadPPStatus" be linked to this event. 8101 PP Upload Equipment has completed preparing the process program for upload subsequent to receipt of a PP_PREP remote command. Recommend that a RPTID containing the SV’s "UploadPPName" and "UploadPPStatus" be linked to this event. 8102 HIT Transition Operator has entered or left HIT Mode. Recommend that a RPTID containing the SV’s "HitMode" be linked to this event. 8103 PP Select OK The equipment has successfully loaded the Process Program requested in the host-initiated remote command PP_SELECT. 8104 PP Select Failed The equipment has detected an error while loading the Process Program requested in the host-initiated remote command PP_SELECT. 8105 PP Modified Indicates the process program has been modified. Recommend that a RPTID containing the SV "PPEditDialog" be linked to this event. 8106 Process Program Clear Process program in RAM has been cleared. 8107 Bond Parameter Changed Process program bond parameter has been changed. 8108 Bond Location Changed Process program bond location has been changed. 8109 PARM_LIMITS_EDITED Default bond parameter limit has been changed 8110 ENTERING_PP_CONV Process Program conversion sequence started 8111 PP_CONV_COMPLETE Process Program conversion sequence completed 8112 PP_CONV_ABORTED Process Program conversion sequence aborted 8113 CE_LTO_OVERRIDE_ON LightTowerOverride ENABLED 8114 CE_LTO_OVERRIDE_OFF LightTowerOverride DISABLED 8115 CE_Bond_Limit_Edited It is triggered while bond limit has been edited. (U2) Page - 173 - of 321 Sep 18, 2020 Rev 4.1 Kulicke & Soffa™ SECS/GEM Interface for K&S Ball Bonders Bonder software version x-xx-x-472-series IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Collection Events CEID Name Description 8116 CE_Hour_Limit_Edited It is triggered while hour limit has been edited. 8117 CE_PrivLevel_Changed It is triggered while privilege level changed. 8118 CE_UPDATE_BOND_PARA M_SV Send out once Bond Parameter related SVIDs updated 8119 CE_INDEX_PROHIBIT_BY_ RAIL_HEIGHT Event to notify host that indexing is prohibited due to unacceptable rail height 8120 CE_AUTO_MINOR_CONV_ COMPLETE CEID for auto minor conversion completion 8130 Misc_PP_Edit Occurs when one of the following process program edits is performed: (U2) - Delete bond site - Resequence wires - Delete wire - Add wire - Regroup wire - Delete reference system - Move reference system - Rotate reference system - Copy reference system - Copy device - Move device - Delete device - Resequence device - Rotate device Recommend that a RPTID containing the status variable "Completed PP Edit" (SVID 3116) be linked to this event. Notes: 1. Reserved for KNET use only. 2. Disabled is the default setting. 8131 CE_Mag_Eject_Opt_Change d Eject magazine option has been changed 8132 CE_PP_SAVE_RENAME_D ELETE PP has been SAVE/RENAME/DELETE. Recommend that a RPTID containing the status variable SV_PP_ID (SVID 3117) and PP_SAVE_RENAME_DELETE_STAT (SVID 3118) be linked to this event. Page - 174 - of 321 Sep 18, 2020 Rev 4.1 Kulicke & Soffa™ SECS/GEM Interface for K&S Ball Bonders Bonder software version x-xx-x-472-series IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Collection Events CEID Name Description 8133 EH_AUTO_FALSE_NSOP_ DETECTED This Event will be sent when backup PRS NSOP auto recovery successfully. 8134 CE_BITSSTATE_BACKUP_ PRS_NSOP_CHANGED BITS State Backup PRS NSOP Changed. 8135 CE_USG_PERSONALITY_V ALUE_CHANGED Change any of the values on “Personality Values" 8136 CE_USG_PERIODIC_SCAN USG PERIODIC SCAN 8139 CE_MULTI_STAGE_BOND_ CHANGED Notify host when cap break in parameter changed. 8140 CE_MDP_CHANGED This event will be trigger when Personality Current Factor Changed 8141 CE_MC_GUI_CAL_CONFIG _CHANGED Machine configured data which related to calibration is changed 8142 CE_ARV_STATE_CHG ARV state is changed from GUI 8150 CE_IMH_RFID_POS_REAC HED Input Mag handler reach RFID position 8151 CE_OMH_RFID_POS_REA CHED Output Mag handler reach RFID position 8152 CE_OMH_RFID_POS_EJE CT_REACHED Output Mag handler reach eject position 8153 CE_IMH_LOAD_TO_ID_PO S_MANUALLY Load input magazine to ID Scan Position by clicking button “Load New Mag to ID Scan Position” 8154 CE_OMH_LOAD_TO_ID_P OS_MANUALLY Load output magazine to ID Scan Position by clicking button “Load New Mag to ID Scan Position” 8155 EH_INPUT_MAG_EJECT_H OST_VALIDATION Before input mag eject, send event to host to do verification, host will decide whether it is possible to eject 8156 EH_OUTPUT_MAG_EJECT _HOST_VALIDATION Before output mag eject, send event to host to do verification, host will decide whether it is possible to eject 8160 CE_ENTER_SAFETY_MOD E Operator request open door, machine enter safety mode 8161 CE_EXIT_SAFETY_MODE Operator request close door, machine enter normal mode 8162 CE_OVERDRIVE_ENABLE D Operator turn on Overdrive key, machine enter safety mode, but is allowed to perform operation 8163 CE_OVERDRIVE_DISABLE D Operator turn off Overdrive key, machine enter normal mode 8164 CE_BYPASS_SAFETY_EN ABLED Operator turn on bypass mode, machine will be able to perform operation in safety mode 8165 CE_BYPASS_SAFETY_DIS ABLED Operator turn off bypass mode, machine will not have exception in safety mode (U2) Page - 175 - of 321 Sep 18, 2020 Rev 4.1 Kulicke & Soffa™ SECS/GEM Interface for K&S Ball Bonders Bonder software version x-xx-x-472-series IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Collection Events CEID Name Description 8200 Temperature_Zone1_Limit_ Event The monitored temperature at pre bond has become either too hot or too cool according to host-defined limits. Recommend that a RPTID containing the DVVAL’s "LimitVariable", "TransitionType" and "EventLimit" be linked to this event. 8201 Temperature Zone 2 Limit_Event The monitored temperature at bond has become either too hot or too cool according to host-defined limits. Recommend that a RPTID containing the DVVAL’s "LimitVariable", "TransitionType" and "EventLimit" be linked to this event. 8202 Temperature_Zone3_Limit_ Event The monitored temperature at post bond has become either too hot or too cool according to host-defined limits. Recommend that a RPTID containing the DVVAL’s "LimitVariable", "TransitionType" and "EventLimit" be linked to this event. 8203 CE_TEMP_ON_OFF_CHAN GED Temp Zone ON/OFF 8204 CE_TEMP_SETPOINT_CH ANGED Temp Setpoint 8205 CE_TEMP_OFFSET_CHAN GED Temp Offset 8206 CE_TEMP_TOL_CHANGED Temp Tolerance 8210 CE_LP_Init_State_Report Initial state of loadport after machine bootup. 8211 CE_LP_Transfer_ReadyToL oad_To_Blocked Port transfer state changes from ready to load to transfer blocked 8212 CE_LP_Transfer_Blocked_T o_ReadyToLoad Port transfer state changes from transfer blocked to ready to load 8213 CE_LP_Transfer_Blocked_T o_ReadyToUnload Port transfer state changes from transfer blocked to ready to unload 8214 CE_LP_Transfer_ReadyToU nload_To_ReadyToLoad Port transfer state changes from ready to unload to ready to load 8215 CE_CarrierID_NotRead_To_ VerifyOK Carrier ID status changes from not read to verify OK 8216 CE_CarrierID_NotRead_To_ WaitForHost Carrier ID status changes from not read to wait for host 8217 CE_CarrierID_WaitForHost_ To_VerifyOK Carrier ID status changes from wait for host to verify ok 8218 CE_CarrierID_WaitForHost_ To_VerifyFail Carrier ID status changes from wait for host to verify fail 8219 CE_CarrierAccess_NotAcce ssed_To_InAccess Carrier Accessing status changes from not accessed to in access 8220 CE_CarrierAccess_InAccess _To_Complete Carrier Accessing status changes from in access to carrier complete (U2) Page - 176 - of 321 Sep 18, 2020 Rev 4.1 Kulicke & Soffa™ SECS/GEM Interface for K&S Ball Bonders Bonder software version x-xx-x-472-series IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Collection Events CEID Name Description 8221 CE_CarrierAccess_InAccess _To_Stopped Carrier Accessing status changes from in access to carrier stopped 8222 CE_Carrier_SlotMap_NotRe ad_To_VerifyOK Carrier Slot Map status changes from not read to verify ok 8223 CE_Carrier_SlotMap_NotRe ad_To_WaitForHost Carrier Slot Map status changes from not read to wait for host 8224 CE_Carrier_SlotMap_WaitF orHost_To_VerifyOK Carrier Slot Map status changes from wait for host to verify ok 8225 CE_Carrier_SlotMap_WaitF orHost_To_VerifyFail Carrier Slot Map status changes from wait for host to verify fail 8226 CE_OHT_Enabled OHT changes from disabled to enabled 8227 CE_OHT_Disabled OHT changes from enabled to disabled 8228 CE_LP_Reservation_NotRe served_To_Reserved Load Port reservation state from not reserved to reserved 8229 CE_LP_Reservation_Reserv ed_To_NotReserved Load Port reservation state from reserved to not reserved 8230 CE_LP_Association_NotAss ociated_To_Associated Load Port association state changes from not associated to associated 8231 CE_LP_Association_Associa ted_To_NotAssociated Load Port association state changes from associated to not associated 8232 CE_Carrier_Location_Chang e Carrier location changes 8233 CE_Carrier_Created Carrier Created 8234 CE_LP_Occupied Load Port is occupied 8235 CE_LP_Empty Load Port is empty 8236 CE_PJ_Queued Process Job is queued 8237 CE_PJ_Queued_To_Setting Up Process Job from queued to setting up 8238 CE_PJ_SettingUp_To_Proc essing Process Job from setting up to processing 8239 CE_PJ_Processing_To_Co mplete Process Job from processing to complete 8240 CE_PJ_Executing_To_Pausi ng Process Job from executing to pausing 8241 CE_PJ_Pausing_To_Pause d Process Job from pausing to paused 8242 CE_PJ_Paused_To_Executi ng Process Job from paused to executing 8243 CE_CJ_Queued Control Job is queued (U2) Page - 177 - of 321 Sep 18, 2020 Rev 4.1 Kulicke & Soffa™ SECS/GEM Interface for K&S Ball Bonders Bonder software version x-xx-x-472-series IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Collection Events CEID Name Description 8244 CE_CJ_Queued_To_Selecte d Control Job from queued to selected 8245 CE_CJ_Selected_To_Execu ting Control Job from selected to executing 8246 CE_CJ_Executing_To_Paus ed Control Job from executing to paused 8247 CE_CJ_Paused_To_Executi ng Control Job from paused to executing 8248 CE_CJ_Executing_To_Com pleted Control Job from executing to completed 8249 CE_Substrate_Process_Star t Substrate starts to be processed 8250 CE_CarrierID_NotRead Carrier ID status is not read 8251 CE_Carrier_SlotMap_NotRe ad Carrier Slot Map status is not read 8252 CE_CarrierAccess_NotAcce ssed Carrier accessing status is not accessed 8253 CE_AccessMode_Manual_T o_Auto Access mode changes from manual to auto 8254 CE_AccessMode_Auto_To_ Manual Access mode changes from auto to manual 8255 MHS_CARRIER_PULLED_I N Substrate is registered at X sensor(at prebond) 8256 CE_CJ_Completed_To_NoS tate Control Job is destroyed after the last output carrier is processed and removed from unload tray 8257 CE_PJ_PostActive_To_Extin ction Process Job is destroyed after its processed output carrier is removed from the unload tray 8258 CE_PJ_QUEUED_To_NoSt ate Process Job is removed from the Queue 8259 CE_Carrier_To_NoState Carrier is removed from unload tray and carrier object is destroyed 8260 CE_CJ_QUEUED_To_NoSt ate Control job is removed from the queue 8267 CE_PP_Loaded_Only_With_ Process_Parameter Apply the process parameter from pp in disk to pp in ram successfully 8268 CE_PP_LastSavedTime_Re ady The last saved timer retrieved from current process program is ready 8300 MHS_MAG_IN_READY Input side magazine is at index position. 8301 MHS_MAG_OUT_READY Output side magazine is at index position. (U2) Page - 178 - of 321 Sep 18, 2020 Rev 4.1 Kulicke & Soffa™ SECS/GEM Interface for K&S Ball Bonders Bonder software version x-xx-x-472-series IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Collection Events CEID Name Description 8302 MHS_MAG_IN_UNLOAD Input side MHS deposits a magazine on the unload tray for pickup by the robot. 8303 MHS_MAG_OUT_UNLOAD Output side MHS deposits a magazine on the unload tray for pickup by the robot. 8304 Package Threshold Reached Device Processed since last CEID8304 triggered reached the configured Threshold by Equipment Constant (ECID1300) 8305 MHS_MAG_IN_BCR_SCAN Input side MHS has scanned bar code of fresh magazine picked up by the equipment. (Backload SMEMA only) This event is predecessor to the EQC initiated remote command "ACCEPT_IN_MAG" or "REJECT_IN_MAG" (S2 F41) which tells the equipment whether it should process or unload the magazine. 8306 MHS_MAG_OUT_BCR_SC AN Output side MHS has scanned bar code of fresh magazine picked up by the equipment. (Backload SMEMA only) This event is predecessor to the EQC initiated remote command "ACCEPT_OUT_MAG" or "REJECT_OUT_MAG" (S2 F41) which tells the equipment whether it should process or unload the magazine. 8307 MHS_MAG_IN_MAG_REQU EST New input magazine required. This event is issued by the equipment concurrent with the SMEMA "ready" signal on the load tray of the input side. 8308 MHS_MAG_OUT_MAG_RE QUEST New output magazine required. This event is issued by the equipment concurrent with the SMEMA "ready" signal on the load tray of the output side. 8309 MHS_MAG_IN_BCR_REJE CT Material ID error at input side. Bar code scan failure on the input side. 8310 MHS_MAG_OUT_BCR_REJ ECT Material ID error at output side. Bar code scan failure on the output side. 8311 CE_IN_LOAD_PORT_STAT E_CHG Equipment preprocessing load port state has changed. Recommend that a RPTID containing a status variable "InLoadPortState" be linked to this event. Backload MMM only). 8312 CE_IN_UNLOAD_PORT_ST ATE_CHG Equipment preprocessing unload port state has changed. Recommend that a RPTID containing a status variable "InUnLoadPortState" be linked to this event. (Backload MMM only). 8313 CE_OUT_LOAD_PORT_ST ATE_CHG Equipment postprocessing load port state has changed. Recommend that a RPTID containing a status variable "OutLoadPortState" be linked to this event. (Backload MMM only). 8314 CE_OUT_UNLOAD_PORT_ STATE_ CHG Equipment postprocessing unload port state has changed. Recommend that a RPTID containing a status variable "OutUnLoadPortState" be linked to this event. event. (Backload MMM only). 8315 Nearing Tool Usage Limit Tool usage is approaching the limit. (U2) Page - 179 - of 321 Sep 18, 2020 Rev 4.1 Kulicke & Soffa™ SECS/GEM Interface for K&S Ball Bonders Bonder software version x-xx-x-472-series IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Collection Events CEID Name Description 8316 NUMERIC_LIMIT_OPTION_ CHANGED This event is triggered when operator changes the Numeric Limit Action from the Privileged Operations Menu. 8317 CE_IDLE_MODE_AUTO_CL AMP_OPEN Idle Mode Auto Clamp Open 8318 CE_REGRIPLEADFRAME_ CHANGED Regrip Leadframe setting changed 8319 CE_REHOMEZ_CHANGED Rehome Z magazine changed 8320 CE_COMM_DISABLED Event that is generated when the operator disables communications using the GUI. (U2) Generated before breaking communications. 8321 CE_Input_Magazine_Loade d Signal this event when Input Magazine Loaded. 8322 CE_Output_Magazine_Load ed Signal this event when Output Magazine Loaded. 8323 CE_Strip_From_Input_Maga zine Signal this event when a strip pulled from the input magazine to the process area and ready for bonding. 8324 CE_Bond_Area_Process_St art Signal this event when the process of a bond area started. This implies ready to bond the first device for each strip. 8325 CE_Device_PRS_Start Signal this event when the initial / first PRS scan is done on each device. 8326 CE_Device_Process_Start Signal this event when bonding begins on each device. 8327 CE_Device_Process_Compl ete Signal this event when the last bond is completed on each device. 8328 CE_Bond_Area_Process_C omplete Signal this event when the process of a bond area completed. This implies the entire strip is processed and ready for ejection. 8329 CE_Strip_To_Output_Magaz ine Signal this event when a strip was moved to the output magazine. 8330 CE_Input_Magazine_Auto_ Unload Signal this event when Input Magazine Unloaded. 8331 CE_Output_Magazine_Auto _Unload Signal this event when Output Magazine Unloaded. 8332 AUTO_CONFIGURATION_ CHANGED Auto configuration changed. 8333 RUN_CONFIGURATION_C HANGED Run configuration changed. 8334 CE_ErrCategory_Changed Error category changed. 8335 CE_2D_Dot_Code_Scan Vision 2D Code Reader Scan once Scan completed 8336 CE_Upload_Strip_Map Strip bonding completed and ready to upload Strip Map Data Page - 180 - of 321 Sep 18, 2020 Rev 4.1 Kulicke & Soffa™ SECS/GEM Interface for K&S Ball Bonders Bonder software version x-xx-x-472-series IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Collection Events CEID Name Description 8337 CE_StripMap_State_Change d It is triggered while turning on or off strip map feature. 8338 OHT_IP_EMPTY_MAG_TR ANSFER_REQ Input mag ready for transfer(OHT only) 8339 OHT_OP_EMPTY_MAG_TR ANSFER_REQ Output mag ready for transfer(OHT only) 8340 CE_Input_Magazine_Ungrip ped Release input mag on unload tray 8341 CE_Output_Magazine_Ungri pped Release output mag on unload tray 8342 MHS_MAG_IN_MANUAL_U NLOAD Send CEID 8342 CE_Input_Magazine_Manual_Unloaded to host when manual eject input magazine. 8343 MHS_MAG_OUT_MANUAL _UNLOAD Send CEID 8343 CE_Output_Magazine_Manual_Unloaded to host when manual eject output magazine. 8344 CE_Input_Magazine_Unload ed Unload input mag complete 8345 CE_Output_Magazine_Unlo aded Unload output mag complete 8346 CE_ECO_CLAMP_OPEN CEID for ECO Clamp Open 8347 CE_ECO_CLAMP_CLOSE CEID for ECO Clamp Close 8348 CE_ECO_IDLE_MODE_EJE CT_CARRIER Start ejecting carrier in idle mode ECO 8349 CE_ECO_AUTO_MODE_EJ ECT_CARRIER Start ejecting carrier in auto mode ECO 8350 CE_GLOBAL_ID_VALIDATI ON_SWITCH_CHANGED Global ID validation switch changed. 8351 CE_DUMMY_STATE_CHAN GED Dummy State Changed 8352 CE_Upload_Substrate_Map Strip bonding is complete and ready to upload xml map data 8354 CE_COMPRESS_FILE_FIN Notify compress file or folder operation complete. 8355 CE_CLAMP_CLOSE_AFTE R_ECO_OPEN Clamp Close 8356 CE_STRIP_PASS_THROU GH A strip marked as pass through by host leaves WHL 8360 CE_WIRE_SPOOL_SEQ_S TART Wire Spool Sequence Start 8361 CE_WIRE_SPOOL_SEQ_E ND Wire Spool Sequence End 8362 CE_WIRE_SPOOL_SEQ_VI OLATION Wire Spool Sequence Violation (U2) Page - 181 - of 321 Sep 18, 2020 Rev 4.1 Kulicke & Soffa™ SECS/GEM Interface for K&S Ball Bonders Bonder software version x-xx-x-472-series IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Collection Events CEID Name Description 8363 CE_WIRE_SPOOL_SEQ_F AILURE Wire Spool Sequence Failure 8364 CE_WIRE_SPOOL_COVER _OPENED Wire Spool Cover Opened 8365 CE_WIRE_SPOOL_COVER _CLOSEED Wire Spool Cover Closed 8366 CE_WIRE_SPOOL_INSTAL LED Wire Spool Installed 8367 CE_WIRE_SPOOL_REMOV ED Wire Spool Removed 8368 CE_WIRE_SPOOL_REMOV AL_SEQ_DONE Wire Spool Removal Sequence Done 8369 CE_WIRE_SPOOL_INSTAL LMENT_SEQ_DONE Wire Spool Installment Sequence Done 8370 CE_SINGLE_INTERACTIVE _TM_OVERRIDDEN Single interactive terminal message is overridden 8371 CE_SINGLE_INTERACTIVE _TM_DESTROYED Single interactive terminal message is destroyed 8372 CE_REQ_PP_FROM_HOST Request PP list from host 8373 CE_SERIAL_PORT_ID_IN ID info is grasped at serial port 8375 CE_Alarm_Assist Operator start assist of error 8376 CE_AUTO_PAUSED_FOR_I NJECT Machine wait for new parts to input conveyor to start bonding 8377 CE_PAUSED_FOR_EJECT Machine cannot eject out parts from output conveyor 8378 CE_CHANGEOVER_START _WT_HOST Changeover start request 8379 CE_AUTO_PAUSED_FOR_I NJECT_RECOVERED Recovery from pause for inject 8380 CE_PAUSED_FOR_EJECT _RECOVERED Recovery from pause for eject 8381 CE_CHANGEOVER_COMP LETE Changeover complete successfully 8382 CE_TOOLCHANGE_START _WT_HOST Tool change start request 8383 CE_WIRECHANGE_START _WT_HOST Wire change start request 8384 CE_TOOLCHANGE_COMP LETE Tool change complete 8385 CE_WIRECHANGE_COMP LETE Wire change complete (U2) Page - 182 - of 321 Sep 18, 2020 Rev 4.1 Kulicke & Soffa™ SECS/GEM Interface for K&S Ball Bonders Bonder software version x-xx-x-472-series IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Collection Events CEID Name Description 8386 CE_PACKAGE_PROCESS_ START Start process a package 8387 CE_CHANGEOVER_ABOR T Abort from changeover sequence 8388 CE_SUBTRATE_PROCESS _COMPLETE Complete process a substrate 8390 WHL_Center_LeadRef_1stL eadBond_BH_Set When SVID 3650 SV_PM_WHL_Center_LeadRef_1stLeadBond_BH has been set, this CEID will be sent to host 8400 Data Set Download Done Equipment has completed or terminated downloading data set using Stream 13 messages. Recommend that a RPTID containing the status variable FileXfrStat (SVID 3048) be linked to this event. 8402 ML_Load_Port_Status_Chan ged Input Mag Handler load tray’s outer sensor status changed. 8403 ML_Unload_Port_Status_Ch anged Input Mag Handler load tray’s outer sensor status changed. 8404 MR_Load_Port_Status_Cha nged Output Mag Handler load tray’s outer sensor status changed. 8405 MR_Unload_Port_Status_Ch anged Output Mag Handler load tray’s outer sensor status changed. 8406 AGV_Control_Status_Chang ed AGV control status changed. 8407 AGV_VALID_Status_Chang ed AGV valid status changed. 8408 EJECT_INPUT_MAGAZINE _NOT_EMPTY Ejected input magazine is not empty. 8409 ML_Load_Limit_Sns_Status _Changed Input Mag Handler load tray’s inner limit sensor status changed 8410 MR_Load_Limit_Sns_Status _Changed Ouput Mag Handler load tray’s inner limit sensor status changed 8411 OHT_Control_Status_Chang ed Overhead Host Transport status changed 8420 CE_Calibration_Successful A successful calibration is done. 8421 CAL_XHAIR_MAP_SUCCE SSFUL Cal Xhair Map Successful 8422 EH_PERIODIC_EFO_HEIG H_CHECK_PERFORM Periodic EFO height calibration performs 8430 CE_CAP_CLEAN_START Cap Clean Start 8431 CE_CAP_CLEAN_TAPE_C HANGED Cap Clean State Changed (U2) Page - 183 - of 321 Sep 18, 2020 Rev 4.1 Kulicke & Soffa™ SECS/GEM Interface for K&S Ball Bonders Bonder software version x-xx-x-472-series IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Collection Events CEID Name Description 8432 CAP_CLEANING_REACHIN G_LIMIT Cap Clean Reach Limit 8440 EDIT_DEVICE_STATUS_D ONE Edit Device Status completed. 8450 CE_LOT_START Triggered when first input mag loaded and Lot becomes ACTIVE 8451 CE_LOT_END Triggered when all L/Fs processed and Lot becomes END 8452 CE_LOT_SPEC_INIT Triggered when WB accept the INIT_LOT_SPEC 8453 CE_LOT_ABORT Triggered when WB completed the LOT under below conditions: (U2) 1.The last input mag specified in lot specification is ejected. 2. No remaining lead freames are in processing in WHL. 3.The output magazine is ejected automatically or manually. 8454 CE_LOT_FIRST_LF_PULLE D_IN Lot First Lead Fream Pulled In 8460 Run_Stop_Pressed Auto Run/Stop Button Pressed 8461 CE_MHS_CONV_DONE_AF T_LOADING_PP PP_Loaded MHS Coversion Done 8462 CE_Manual_Skip_Device Manual Skip Device 8463 CE_AUTO_ERR_SKIP_UNI T Auto Error Skip Device:Notify host when configured auto error triggered skip unit 8464 IND_NOT_BONDED_CARRI ER_JAM JAM error with not completely bonded LF 8470 CE_BONDSITE_CHKSUM_ MISMATCH Bond Site Location checksum mismatch (Prevent for wrong bond) 8471 CE_WRONG_BOND_CHEC KSUM_ERROR_DETECT Wrong Bond Checksum Error Detected 8472 CE_Alarm_Set General Alarm Set Event.Report should contain DVID 10009/DVID10010 when link this event. 8473 CE_Device_Alarm_Detect CEID triggered when an alarm detect 8480 CE_CARRIER_EJECTED_C OMPLETE Carrier Ejected to Mag Completed 8481 CE_OHT_Insp_Mode_Statu s_Changed Insp mode status changed 8482 CE_OHT_INSP_PENDING_ TO_READY Insp pending to ready 8483 CE_OHT_Insp_Ready MC ready to inspect 8484 CE_OHT_Insp_Confirm Inspection confirmed 8485 CE_OHT_Insp_Retry Inspection need retry Page - 184 - of 321 Sep 18, 2020 Rev 4.1 Kulicke & Soffa™ SECS/GEM Interface for K&S Ball Bonders Bonder software version x-xx-x-472-series IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Collection Events CEID Name Description 8486 CE_OHT_MC_START_RUN User press Run/Stop, Mc try to Run 8487 CE_OHT_INPUT_LOAD_RE QUEST Input load tray empty 8488 CE_OHT_OUTPUT_LOAD_ REQUEST Output load tray empty 8489 CE_MHS_MAG_GRIPPED Input Mag Gripped by input mag handler 8490 CE_MHS_MAG_GRIPPED_ O Output Mag Gripped by output mag handler 8491 ML_Load_Port_Occupied Input load tray sensor blocked 8492 MR_Load_Port_Occupied output load tray sensor blocked 8493 ML_Load_Port_MANUAL_E mpty Input load tray sensor unblocked due to magazine removed 8494 MR_Load_Port_MANUAL_E mpty output load tray sensor unblocked due to magazine removed 8495 ML_Load_Limit_Port_Manau l_Empty Input load tray limit sensor unblocked due to magazine removed 8496 MR_Load_Limit_Port_Mana ul_Empty output load tray limit sensor unblocked due to magazine removed 8497 ML_Unload_Port_Manual_E mpty Operator pick input magazine before it reach tray sensor position 8498 MR_Unload_Port_Manual_E mpty Operator pick output magazine before it reach tray sensor position 8499 CE_IMH_ID_PRE_REQUES T Pre-request mag id for input magazine 8500 CE_OMH_ID_PRE_REQUE ST Pre-request mag id for output magazine 8501 MHS_IMH_ID_PRE_SCAN_ COMPLETED Pre-scan mag id for input magazine sucessfully 8502 MHS_OMH_ID_PRE_SCAN _COMPLETED Pre-scan mag id for output magazine sucessfully 8503 CE_OUT_REPORT_EVENT Trigger after all carriers processed and transferred into the magazine in unloader port 8504 CE_IMH_Start_Auto_Ungrip ped Trigger when input magazine handler start to ungrip input magazine 8505 CE_OMH_Start_Auto_Ungri pped Trigger when output magazine handler start to ungrip output magazine 8506 CE_IMH_Start_Manual_Ung ripped Trigger when input magazine handler start to ungrip input magazine 8507 CE_OMH_Start_Manual_Un gripped Trigger when output magazine handler start to ungrip output magazine (U2) Page - 185 - of 321 Sep 18, 2020 Rev 4.1 Kulicke & Soffa™ SECS/GEM Interface for K&S Ball Bonders Bonder software version x-xx-x-472-series IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Collection Events CEID Name Description 8508 CE_Alarm_Report EH dialog pop up 8509 CE_Alarm_Clear EH dialog clear 8510 WIRE_INSP_UNIT_INSPEC T_COMPLETED Wire inspection of a unit has completed 8511 WIRE_INSP_CONFIG_CHA NGED Wire inspection config has been changed 8512 WIRE_INSP_STATISTICS_ RESET Wire inspection statistics has been reset 8901 GEM_CTRL_STATE_CHAN GED The equipment has changed control state. Recommend that a RPTID containing the SV’s "ControlState" and "PreviousControlState" be linked to this event. 8902 CE_LogFile_Shuffled Triggered while log file is full (1.3MB) and shuffled. 9010 PDT-EFO-OPEN-SET Alarm set: PDT-EFO-OPEN 9011 PDT-EFO-OPEN-CLEAR Alarm clear: PDT-EFO-OPEN 9012 PDT-EFO-OPEN-EXCLUDE PDT EFO OPEN for MTBA. 9020 PDT-EFO-SHORT-SET Alarm set: PDT-EFO-SHORT 9021 PDT-EFO-SHORT-CLEAR Alarm clear: PDT-EFO-SHORT 9030 PDT-EFO-ERROR-SET Alarm set: PDT-EFO-ERROR 9031 PDT-EFO-ERROR-CLEAR Alarm clear: PDT-EFO-ERROR 9040 EFO-HAZARD-SET Alarm set: EFO-HAZARD 9041 EFO-HAZARD-CLEAR Alarm clear: EFO-HAZARD 9050 PDT-WIREFEED-ERRORSET Alarm set: PDT-WIREFEED-ERROR 9051 PDT-WIREFEED-ERRORCLEAR Alarm clear: PDT-WIREFEED-ERROR 9060 MANUAL-EFO-OPEN-SET Alarm set: MANUAL-EFO-OPEN 9061 MANUAL-EFO-OPENCLEAR Alarm clear: MANUAL-EFO-OPEN 9070 MANUAL-EFO-SHORT-SET Alarm set: MANUAL-EFO-SHORT 9071 MANUAL-EFO-SHORTCLEAR Alarm clear: MANUAL-EFO-SHORT 9080 MANUAL-EFO-ERROR-SET Alarm set: MANUAL-EFO-ERROR 9081 MANUAL-EFO-ERRORCLEAR Alarm clear: MANUAL-EFO-ERROR 9090 MANUAL-EFO-HAZARDSET Alarm set: MANUAL-EFO-HAZARD (U2) Page - 186 - of 321 Sep 18, 2020 Rev 4.1 Kulicke & Soffa™ SECS/GEM Interface for K&S Ball Bonders Bonder software version x-xx-x-472-series IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Collection Events CEID Name Description 9091 MANUAL-EFO-HAZARDCLEAR Alarm clear: MANUAL-EFO-HAZARD 9100 AUTO-TEMP-OUT-OFLIMITS-SET Alarm set: AUTO-TEMP-OUT-OF-LIMITS 9101 AUTO-TEMP-OUT-OFLIMITS-CLEAR Alarm clear: AUTO-TEMP-OUT-OF-LIMITS 9110 FATAL-ERROR-SET Alarm set: FATAL-ERROR 9111 FATAL-ERROR-CLEAR Alarm clear: FATAL-ERROR 9120 OS-ERROR-SET Alarm set: OS-ERROR 9121 OS-ERROR- CLEAR Alarm clear: OS-ERROR 9130 INTERNAL-ERROR-SET Alarm set: INTERNAL-ERROR 9131 INTERNAL-ERROR-CLEAR Alarm clear: INTERNAL-ERROR 9140 PROCESS-ERROR-SET Alarm set: PROCESS-ERROR 9141 PROCESS-ERROR-CLEAR Alarm clear: PROCESS-ERROR 9150 MHS_MOTOR_DRIVER_ER ROR-SET Alarm set: MHS_MOTOR_DRIVER_ERROR 9151 MHS_MOTOR_DRIVER_ER ROR-CLEAR Alarm clear: MHS_MOTOR_DRIVER_ERROR 9160 IND_DEVICE_OVERHEATE D-SET Alarm set: IND_DEVICE_OVERHEATED 9161 IND_DEVICE_OVERHEATE D-CLEAR Alarm clear: IND_DEVICE_OVERHEATED 9170 IND_NO_CLAMP_VACUUM -SET Alarm set: IND_NO_CLAMP_VACUUM 9171 IND_NO_CLAMP_VACUUM -CLEAR Alarm clear: IND_NO_CLAMP_VACUUM 9180 IND_CARRIER_JAM-SET Alarm set: IND_CARRIER_JAM 9181 IND_CARRIER_JAMCLEAR Alarm clear: IND_CARRIER_JAM 9190 MH_BAD_GRIPPER_CHAN GE-SET Alarm set: MH_BAD_GRIPPER_CHANGE 9191 MH_BAD_GRIPPER_CHAN GE–CLEAR Alarm clear: MH_BAD_GRIPPER_CHANGE 9220 MON-X-MOTOR-OVERTEMP–SET Alarm set: MON-X-MOTOR-OVER-TEMP 9221 MON-X-MOTOR-OVERTEMP–CLEAR Alarm clear: MON-X-MOTOR-OVER-TEMP (U2) Page - 187 - of 321 Sep 18, 2020 Rev 4.1 Kulicke & Soffa™ SECS/GEM Interface for K&S Ball Bonders Bonder software version x-xx-x-472-series IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Collection Events CEID Name Description 9230 MON-YL-MOTOR-OVERTEMP–SET Alarm set: MON-YL-MOTOR-OVER-TEMP 9231 MON-YL-MOTOR-OVERTEMP–CLEAR Alarm clear: MON-YL-MOTOR-OVER-TEMP 9240 MON-YR-MOTOR-OVERTEMP–SET Alarm set: MON-YR-MOTOR-OVER-TEMP 9241 MON-YR-MOTOR-OVERTEMP–CLEAR Alarm clear: MON-YR-MOTOR-OVER-TEMP 9250 MON-Z-MOTOR-OVERTEMP–SET Alarm set: MON-Z-MOTOR-OVER-TEMP 9251 MON-Z-MOTOR-OVERTEMP–CLEAR Alarm clear: MON-Z-MOTOR-OVER-TEMP 9260 MON-T-MOTOR-OVERTEMP–SET Alarm set: MON-T-MOTOR-OVER-TEMP 9261 MON-T-MOTOR-OVERTEMP–CLEAR Alarm clear: MON-T-MOTOR-OVER-TEMP 9270 MON-RACK-OVER-TEMP– SET Alarm set: MON-RACK-OVER-TEMP 9271 MON-RACK-OVER-TEMP– CLEAR Alarm clear: MON-RACK-OVER-TEMP 9280 MON-PSUPPLY-OVERTEMP–SET Alarm set: MON-PSUPPLY-OVER-TEMP 9281 MON-PSUPPLY-OVERTEMP–CLEAR Alarm clear: MON-PSUPPLY-OVER-TEMP 9290 MON-WIREFEED-AIRDOWN–SET Alarm set: MON-WIREFEED-AIR-DOWN 9291 MON-WIREFEED-AIRDOWN–CLEAR Alarm clear: MON-WIREFEED-AIR-DOWN 9300 MON-SYSTEM-AIR-DOWN– SET Alarm set: MON-SYSTEM-AIR-DOWN 9301 MON-SYSTEM-AIR-DOWN– CLEAR Alarm clear: MON-SYSTEM-AIR-DOWN 9310 MON-STEP1-BD-FAULT– SET Alarm set: MON-STEP1-BD-FAULT 9311 MON-STEP1-BD-FAULT– CLEAR Alarm clear: MON-STEP1-BD-FAULT 9320 MON-STEP2-BD-FAULT– SET Alarm set: MON-STEP2-BD-FAULT 9321 MON-STEP2-BD-FAULT– CLEAR Alarm clear: MON-STEP2-BD-FAULT (U2) Page - 188 - of 321 Sep 18, 2020 Rev 4.1 Kulicke & Soffa™ SECS/GEM Interface for K&S Ball Bonders Bonder software version x-xx-x-472-series IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Collection Events CEID Name Description 9330 TEMP_ZONE_OPEN_LOOP _ERROR–SET Alarm set: TEMP_ZONE_OPEN_LOOP_ERROR 9331 TEMP_ZONE_OPEN_LOOP _ERROR–CLEAR Alarm clear: TEMP_ZONE_OPEN_LOOP_ERROR 9340 POWER-FAILURE–SET Alarm set: POWER-FAILURE 9341 POWER-FAILURE–CLEAR Alarm clear: POWER-FAILURE 9350 POWER-LOW–SET Alarm set: POWER-LOW 9351 POWER-LOW–CLEAR Alarm clear: POWER-LOW 9360 POWER-OVERTEMP–SET Alarm set: POWER-OVERTEMP 9361 POWER-OVERTEMP– CLEAR Alarm clear: POWER-OVERTEMP 9370 SYSTEM-FAILURE–SET Alarm set: SYSTEM-FAILURE 9371 SYSTEM-FAILURE–CLEAR Alarm clear: SYSTEM-FAILURE 9380 PFAIL-DETECT–SET Alarm set: PFAIL-DETECT 9381 PFAIL-DETECT–CLEAR Alarm clear: PFAIL-DETECT 9390 PFAIL-SHUTDOWNINCOMPLETE–SET Alarm set: PFAIL-SHUTDOWN-INCOMPLETE 9391 PFAIL-SHUTDOWNINCOMPLETE–CLEAR Alarm clear: PFAIL-SHUTDOWN-INCOMPLETE 9400 PFAIL-SHUTDOWNUNUSABLE–SET Alarm set: PFAIL-SHUTDOWN-UNUSABLE 9401 PFAIL-SHUTDOWNUNUSABLE–CLEAR Alarm clear: PFAIL-SHUTDOWN-UNUSABLE 9410 PFAIL-RECOVERYFAILURE–SET Alarm set: PFAIL-RECOVERY-FAILURE 9411 PFAIL-RECOVERYFAILURE–CLEAR Alarm clear: PFAIL-RECOVERY-FAILURE 9420 PFAIL-DIRTY-PROGRAM– SET Alarm set: PFAIL-DIRTY-PROGRAM 9421 PFAIL-DIRTY-PROGRAM– CLEAR Alarm clear: PFAIL-DIRTY-PROGRAM 9430 PFAIL-BONDOFF-FAILEDSET Alarm set: PFAIL-BONDOFF-FAILED 9431 PFAIL-BONDOFF-FAILEDCLEAR Alarm clear: PFAIL-BONDOFF-FAILED 9440 PFAIL-SHUTDOWNPROCESS-ERROR–SET Alarm set: PFAIL-SHUTDOWN-PROCESS-ERROR (U2) Page - 189 - of 321 Sep 18, 2020 Rev 4.1 Kulicke & Soffa™ SECS/GEM Interface for K&S Ball Bonders Bonder software version x-xx-x-472-series IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Collection Events CEID Name Description 9441 PFAIL-SHUTDOWNPROCESS-ERROR–CLEAR Alarm clear: PFAIL-SHUTDOWN-PROCESS-ERROR 9450 PFAIL-SHUTDOWN-FATALERROR–SET Alarm set: PFAIL-SHUTDOWN-FATAL-ERROR 9451 PFAIL-SHUTDOWN-FATALERROR–CLEAR Alarm clear: PFAIL-SHUTDOWN-FATAL-ERROR 9460 SERVO_FAULT–SET Alarm set: SERVO_FAULT 9461 SERVO_FAULT–CLEAR Alarm clear: SERVO_FAULT 9470 PARM_TYPE_INVALID-SET Alarm set: PARM_TYPE_INVALID 9471 PARM_TYPE_INVALIDCLEAR Alarm clear: PARM_TYPE_INVALID 9480 EH_FAINT6_FAULT-SET Alarm Set: EH_FAINT6_FAULT 9481 EH_FAINT6_FAULT-CELAR Alarm Clear: EH_FAINT6_FAULT 9490 PDT-UNEXPECTED-NSOPSET Alarm Set: PDT Error - Unexpected BITS Error NSOP 9491 PDT-UNEXPECTED-NSOPCLEAR Alarm Clear: PDT Error - Unexpected BITS Error NSOP 9492 PDT-UNEXPECTED-NSOPEXCLUDE PDT NSOP for MTBA. 9500 PDT-UNEXPECTED NSOLSET PDT Error - BITS Error NSOL 9501 PDT-UNEXPECTED-NSOLCLEAR Alarm Clear: PDT Error - Unexpected BITS Error NSOL 9502 PDT-UNEXPECTED-NSOLEXCLUDE PDT NSOL for MTBA. 9510 PDT-UNEXPECTED-SHTLSET Alarm Set: Unexpected PDT Error - BITS Error SHTL 9511 PDT-UNEXPECTED-SHTLCLEAR Alarm Clear: PDT Error – Unexpected BITS Error CLEAR 9512 PDT-UNEXPECTED-SHTLEXCLUDE PDT SHTL for MTBA. 9520 AUTO-ALIGN-FIND-FAILSET Alarm Set: ALIGN status - inadequate eye points found 9521 AUTO-ALIGN-FIND-FAILCLEAR Alarm Clear: ALIGN status - inadequate eye points found 9530 AUTO-ALIGN-LTOL-FAILSET Alarm Set: ALIGN status - line distance outside tolerance 9531 AUTO-ALIGN-LTOL-FAILCLEAR Alarm Clear: ALIGN status - line distance outside tolerance (U2) Page - 190 - of 321 Sep 18, 2020 Rev 4.1 Kulicke & Soffa™ SECS/GEM Interface for K&S Ball Bonders Bonder software version x-xx-x-472-series IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Collection Events CEID Name Description 9540 AUTO-VLL-FIND-FAIL-SET Alarm Set: ALIGN status - line distance outside tolerance 9541 AUTO-VLL-FIND-FAILCLEAR Alarm Clear: ALIGN status - line distance outside tolerance 9550 AUTO-VLL-WIDTH-FAILSET Alarm Set: VLL Error - lead width out of tolerance 9551 AUTO-VLL-WIDTH-FAILCLEAR Alarm Clear: VLL Error - lead width out of tolerance 9560 AUTO-XHAIR-ERROR-SET Alarm Set: Auto X Hair Correction Error 9561 AUTO-XHAIR-ERRORCLEAR Alarm Clear: Auto X Hair Correction Error 9570 AUTO-DRIFT-ERROR-SET Alarm Set: X Hair Offset Inaccurate 9571 AUTO-DRIFT-ERRORCLEAR Alarm Clear: X Hair Offset Inaccurate 9580 AUTO-TOOL-USAGE-LIMITEXCEEDED-SET Alarm Set: Tool Usage Limit Exceeded 9581 AUTO-TOOL-USAGE-LIMITEXCEEDED-CLEAR Alarm Clear: Tool Usage Limit Exceeded 9590 AUTO-BONDHEADSAFETY-VIOLATION-SET Alarm Set: Bond Head Safety Violation 9591 AUTO-BONDHEADSAFETY-VIOLATIONCLEAR Alarm Clear: Bond Head Safety Violation 9600 AUTO-BONDHEAD-TABLEVIOLATION-SET Alarm Set: Bond Head Table Size Violation #254 9601 AUTO-BONDHEAD-TABLEVIOLATION-CLEAR Alarm Clear: Bond Head Table Size Violation #254 9610 AUTO-AIR-OUT-OF-LIMITSSET Alarm Set: Missing air supply #262 9611 AUTO-AIR-OUT-OF-LIMITSCLEAR Alarm Clear: Missing air supply #262 9620 AUTO-TEMP-OUT-OF-ADRANGE-SET Alarm Set: Temperature Sensor Out of A-D Range #264 9621 AUTO-TEMP-OUT-OF-ADRANGE-CLEAR Alarm Clear: Temperature Sensor Out of A-D Range #264 9630 AUTO-TEMP-OUT-OF-ADRANGE-CLXC-SET Alarm Set: Temperature Sensor for Zone 4 Out of A-D Range #265 9631 AUTO-TEMP-OUT-OF-ADRANGE-CLXC-CLEAR Alarm Clear: Temperature Sensor for Zone 4 Out of A-D Range #265 9640 MHS_WORKHOLDER_NOT _EMPTY_SET Alarm Set: Work holder not empty (U2) Page - 191 - of 321 Sep 18, 2020 Rev 4.1 Kulicke & Soffa™ SECS/GEM Interface for K&S Ball Bonders Bonder software version x-xx-x-472-series IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Collection Events CEID Name Description 9641 MHS_WORKHOLDER_NOT _EMPTY_CLEAR Alarm Clear: Work holder not empty 9650 MHS_PUL_CARRIER_ALR EADY_PRESENT_SET Alarm Set: Leadframe cannot be pulled in - one already present 9651 MHS_PUL_CARRIER_ALR EADY_PRESENT_CLEAR Alarm Clear: Leadframe cannot be pulled in - one already present 9660 FRL_WILL_REACH_LIMIT_I NDEX-SET Alarm Clear: Leadframe cannot be pulled in - one already present 9661 FRL_WILL_REACH_LIMIT_I NDEX-CLEAR Alarm Clear: Leadframe cannot be pulled in - one already present 9670 PUL_HOME_NOT_FOUNDSET Alarm Set: Puller's home not found 9671 PUL_HOME_NOT_FOUNDCLEAR Alarm Clear: Puller's home not found 9680 IND_HOME_NOT_FOUNDSET Alarm Set: Indexer's home not found 9681 IND_HOME_NOT_FOUNDCLEAR Alarm Clear: Indexer's home not found 9690 FRL_HOME_NOT_FOUNDSET Alarm Set: Front rail's home not found 9691 FRL_HOME_NOT_FOUNDCLEAR Alarm Clear: Front rail's home not found 9700 RRL_HOME_NOT_FOUNDSET Alarm Set: Rear rail's home not found 9701 RRL_HOME_NOT_FOUNDCLEAR Alarm Clear: Rear rail's home not found 9710 CI_HOME_NOT_FOUNDSET Alarm Set: Clamp's home not found 9711 CI_HOME_NOT_FOUNDCLEAR Alarm Clear: Clamp's home not found 9720 HB_HOME_NOT_FOUNDSET Alarm Set: Heat block's home not found 9721 HB_HOME_NOT_FOUNDCLEAR Alarm Clear: Heat block's home not found 9730 GRP_HOME_NOT_FOUNDSET Alarm Set: Indexer gripper's home not found 9731 GRP_HOME_NOT_FOUNDCLEAR Alarm Clear: Indexer gripper's home not found 9740 IND_CARRIER_EDGE_NOT _FOUND-SET Alarm Set: Lead frame's X registration edge not found (U2) Page - 192 - of 321 Sep 18, 2020 Rev 4.1 Kulicke & Soffa™ SECS/GEM Interface for K&S Ball Bonders Bonder software version x-xx-x-472-series IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Collection Events CEID Name Description 9741 IND_CARRIER_EDGE_NOT _FOUND-CLEAR Alarm Clear: Lead frame's X registration edge not found 9750 IND_DEVICE_NOT_FOUND -SET Alarm Set: Device's eye point not found 9751 IND_DEVICE_NOT_FOUND -CLEAR Alarm Clear: Device's eye point not found 9760 IND_BOND_TEACH_FAILU RE-SET Alarm set: teach bonding position failure. 9761 IND_BOND_TEACH_FAILU RE-CLEAR Alarm clear: teach bonding position failure. 9770 PUL_CARRIER_NOT_PRE SENT-SET Alarm Set: Empty input magazine slot 9771 PUL_CARRIER_NOT_PRE SENT-CLEAR Alarm Clear: Empty input magazine slot 9780 PUL_CARRIER_EDGE_NO T_FOUND-SET Alarm Set: Lead frame's X registration edge not found 9781 PUL_CARRIER_EDGE_NO T_FOUND-CLEAR Alarm Clear: Lead frame's X registration edge not found 9790 MHS_INIT_FAILURE-SET Alarm Set: MHS initialization failed 9791 MHS_INIT_FAILURECLEAR Alarm Clear: MHS initialization failed 9800 RAILS_LIMIT_DETECTEDSET Alarm Set: Rail limit sensor was blocked 9801 RAILS_LIMIT_DETECTEDCLEAR Alarm Clear: Rail limit sensor was blocked 9810 FRL_LIMIT_DETECTEDSET Alarm Set: Front rail limit sensor was blocked 9811 FRL_LIMIT_DETECTEDCLEAR Alarm Clear: Front rail limit sensor was blocked 9820 RRL_LIMIT_DETECTEDSET Alarm Set: Rear rail limit sensor was blocked 9821 RRL_LIMIT_DETECTEDCLEAR Alarm Clear: Rear rail limit sensor was blocked 9830 Y_COOR_EXCEEDS_LIMIT -SET Alarm Set: Y correction requested exceeds limit 9831 Y_COOR_EXCEEDS_LIMIT -CLEAR Alarm Clear: Y correction requested exceeds limit 9840 X_COOR_EXCEEDS_UPDA TE_LIMIT-SET Alarm Set: X correction exceeds update limit (U2) Page - 193 - of 321 Sep 18, 2020 Rev 4.1 Kulicke & Soffa™ SECS/GEM Interface for K&S Ball Bonders Bonder software version x-xx-x-472-series IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Collection Events CEID Name Description 9841 X_COOR_EXCEEDS_UPDA TE_LIMIT-CLEAR Alarm Clear: X correction exceeds update limit 9850 Y_COOR_EXCEEDS_UPDA TE_LIMIT-SET Alarm Set: Y correction exceeds update limit 9851 Y_COOR_EXCEEDS_UPDA TE_LIMIT-CLEAR Alarm Clear: Y correction exceeds update limit 9860 RLS_INDEX_ERROR-SET Alarm Set: Rail index motion error 9861 RLS_INDEX_ERRORCLEAR Alarm Clear: Rail index motion error 9870 MH_SLOT_SENSOR_BLOC KED_NONE_MAG-SET Alarm Set: Work holder detected slot sensor blocked 9871 MH_SLOT_SENSOR_BLOC KED_NONE_MAG-CLEAR Alarm Clear: Work holder detected slot sensor blocked 9880 MH_SLOT_SENSOR_BLOC KED_NONE_MAG_O-SET Alarm Set: Work holder detected slot sensor blocked 9881 MH_SLOT_SENSOR_BLOC KED_NONE_MAG_OCLEAR Alarm Clear: Work holder detected slot sensor blocked 9890 MH_SLOT_SENSOR_BLOC KED-SET Alarm Set: Input Mag Handler detected slot sensor blocked 9891 MH_SLOT_SENSOR_BLOC KED-CLEAR Alarm Clear: Input Mag Handler detected slot sensor blocked 9900 MH_SLOT_SENSOR_BLOC KED_O-SET Alarm Set: Output Mag Handler detected slot sensor blocked 9901 MH_SLOT_SENSOR_BLOC KED_O-CLEAR Alarm Clear: Output Mag Handler detected slot sensor blocked 9910 MH_Y_SENSOR_FAILURESET Alarm Set: Input Y motor: motion error or home sensor timeout 9911 MH_Y_SENSOR_FAILURECLEAR Alarm Clear: Input Y motor: motion error or home sensor timeout 9920 MH_Y_SENSOR_FAILURE_ O-SET Alarm Set: Output mag handler Y home error 9921 MH_Y_SENSOR_FAILURE_ O-CLEAR Alarm Clear: Output mag handler Y home error 9930 MH_Z_SENSOR_FAILURESET Alarm Set: Input mag handler Z home error 9931 MH_Z_SENSOR_FAILURECLEAR Alarm Clear: Input mag handler Z home error 9940 MH_Z_SENSOR_FAILURE_ O-SET Alarm Set: Output mag handler Z home error (U2) Page - 194 - of 321 Sep 18, 2020 Rev 4.1 Kulicke & Soffa™ SECS/GEM Interface for K&S Ball Bonders Bonder software version x-xx-x-472-series IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Collection Events CEID Name Description 9941 MH_Z_SENSOR_FAILURE_ O-CLEAR Alarm Clear: Output mag handler Z home error 9950 RRL_WILL_REACH_LIMIT_I NDEX-SET Alarm Set: rear rail will reach limit during device index 9951 RRL_WILL_REACH_LIMIT_I NDEX-CLEAR Alarm Clear: rear rail will reach limit during device index 9960 MH_FAILED_STORE_MAGSET Alarm Set: Input mag handler failed unload 9961 MH_FAILED_STORE_MAGCLEAR Alarm Clear: Input mag handler failed unload 9970 MH_FAILED_STORE_MAG _O-SET Alarm Set: Output mag handler failed unload 9971 MH_FAILED_STORE_MAG _O-CLEAR Alarm Clear: Output mag handler failed unload 9980 MH_FAILED_GET_MAGSET Alarm Set: Input mag handler: Failed to load mag (calibration) 9981 MH_FAILED_GET_MAGCLEAR Alarm Clear: Input mag handler: Failed to load mag (calibration) 9990 MH_FAILED_GET_MAG_OSET Alarm Set: Output mag handler: Failed to load mag (calibration) 9991 MH_FAILED_GET_MAG_OCLEAR Alarm Clear: Output mag handler: Failed to load mag (calibration) 10000 MH_INPUT_TRAY_EMPTYSET Alarm Set: Input magazine handler, Load tray is empty 10001 MH_INPUT_TRAY_EMPTYCLEAR Alarm Clear: Input magazine handler, Load tray is empty 10010 MH_INPUT_TRAY_EMPTY_ O-SET Alarm Set: Output magazine handler, Load tray is empty 10011 MH_INPUT_TRAY_EMPTY_ O-CLEAR Alarm Clear: Output magazine handler, Load tray is empty 10020 MH_OUTPUT_TRAY_FULLSET Alarm Set: Input magazine handler, tray full sensor detected 10021 MH_OUTPUT_TRAY_FULLCLEAR Alarm Clear: Input magazine handler, tray full sensor detected 10030 MH_OUTPUT_TRAY_FULL _O-SET Alarm Set: Output magazine handler, tray full sensor detected 10031 MH_OUTPUT_TRAY_FULL _O-CLEAR Alarm Clear: Output magazine handler, tray full sensor 10040 MH_G_SENSOR_FAILURESET Alarm Set: Input G motor: motion error or home sensor timeout (U2) Page - 195 - of 321 Sep 18, 2020 Rev 4.1 Kulicke & Soffa™ SECS/GEM Interface for K&S Ball Bonders Bonder software version x-xx-x-472-series IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Collection Events CEID Name Description 10041 MH_G_SENSOR_FAILURECLEAR Alarm Clear: Input G motor: motion error or home sensor timeout 10050 MH_G_SENSOR_FAILURE _O-SET Alarm Set: Output G motor: motion error or home sensor timeout 10051 MH_G_SENSOR_FAILURE _O-CLEAR Alarm Clear: Output G motor: motion error or home sensor timeout 10060 MH_FAILED_OPERATION_ CHESS-SET Alarm Set: Input magazine handler, Cannot correct the situation please chess to a safe location 10061 MH_FAILED_OPERATION_ CHESS-CLEAR Alarm Clear: Input magazine handler, Cannot correct the situation please chess to a safe location 10070 MH_FAILED_OPERATION_ CHESS_O-SET Alarm Set: Output magazine handler, Cannot correct the situation please chess to a safe location 10071 MH_FAILED_OPERATION_ CHESS_O-CLEAR Alarm Clear: Output magazine handler, Cannot correct the situation please chess to a safe location 10080 FRL_WILL_REACH_LIMIT_ CORR-SET Alarm Set: Front rail will reach limit during device correction 10081 FRL_WILL_REACH_LIMIT_ CORR-CLEAR Alarm Clear: Front rail will reach limit during device correction 10090 RRL_WILL_REACH_LIMIT_ CORR-SET Alarm Set: Rear rail will reach limit during device correction 10091 RRL_WILL_REACH_LIMIT_ CORR-CLEAR Alarm Clear: Rear rail will reach limit during device correction 10100 FRL_LIMIT_REACHED_IND EX-SET Alarm Set: Front rail reached limit during device index 10101 FRL_LIMIT_REACHED_IND EX-CLEAR Alarm Clear: Front rail reached limit during device index 10110 MH_TRAY_NOT_DETECTE D-SET Alarm Set: Input mag handler tray detect sensor not blocked 10111 MH_TRAY_NOT_DETECTE D-CLEAR Alarm Clear: Input mag handler tray detect sensor not blocke 10120 MH_TRAY_NOT_DETECTE D_O-SET Alarm Set: Output mag handler tray detect sensor not blocked 10121 MH_TRAY_NOT_DETECTE D_O-CLEAR Alarm Clear: Output mag handler tray detect sensor not blocked 10130 MH_TRAY_DETECT_SENS OR_FAILURE-SET Alarm Set: Input mag handler tray detect sensor state error 10131 MH_TRAY_DETECT_SENS OR_FAILURE-CLEAR Alarm Clear: Input mag handler tray detect sensor state error 10140 MH_TRAY_DETECT_SENS OR_FAILURE_O-SET Alarm Set: Output mag handler tray detect sensor state error (U2) Page - 196 - of 321 Sep 18, 2020 Rev 4.1 Kulicke & Soffa™ SECS/GEM Interface for K&S Ball Bonders Bonder software version x-xx-x-472-series IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Collection Events CEID Name Description 10141 MH_TRAY_DETECT_SENS OR_FAILURE_O-CLEAR Alarm Clear: Output mag handler tray detect sensor state error 10150 MH_GRIP_SENSORS_FAIL ED-SET Alarm Set: Input mag handler gripping sensor states not same 10151 MH_GRIP_SENSORS_FAIL ED-CLEAR Alarm Clear: Input mag handler gripping sensor states not same 10160 MH_GRIP_SENSORS_FAIL ED_O-SET Alarm Set: Output mag handler gripping sensor states not same 10161 MH_GRIP_SENSORS_FAIL ED_O-CLEAR Alarm Clear: Output mag handler gripping sensor states not same 10170 MH_GRIP_ACTIVE_INVALI D-SET Alarm Set: Input mag handler grip sensor blocked 10171 MH_GRIP_ACTIVE_INVALI D-CLEAR Alarm Clear: Input mag handler grip sensor blocked 10180 MH_GRIP_ACTIVE_INVALI D_O-SET Alarm Set: Output mag handler grip sensor blocked 10181 MH_GRIP_ACTIVE_INVALI D_O-CLEAR Alarm Clear: Output mag handler grip sensor blocked 10190 MH_TOUCH_ACTIVE_INVA LID-SET Alarm Set: Input mag handler touch sensor blocked 10191 MH_TOUCH_ACTIVE_INVA LID-CLEAR Alarm Clear: Input mag handler touch sensor blocked 10200 MH_TOUCH_ACTIVE_INVA LID_O-SET Alarm Set: Output mag handler touch sensor blocked 10201 MH_TOUCH_ACTIVE_INVA LID_O-CLEAR Alarm Clear: Output mag handler touch sensor blocked 10210 MH_STATE_BAD_SENSOR S_GRIP-SET Alarm Set: Input mag handler gripping sensors blocked 10211 MH_STATE_BAD_SENSOR S_GRIP-CLEAR Alarm Clear: Input mag handler gripping sensors blocked 10220 MH_STATE_BAD_SENSOR S_GRIP_O-SET Alarm Set: Output mag handler gripping sensors blocked 10221 MH_STATE_BAD_SENSOR S_GRIP_O-CLEAR Alarm Clear: Output mag handler gripping sensors blocked 10230 MH_FAILED_GET_MAGSET Alarm Set: Input mag handler: Fail to load mag (setup) 10231 MH_FAILED_GET_MAGCLEAR Alarm Clear: Input mag handler: Fail to load mag (setup) 10240 MH_FAILED_GET_MAG_OSET Alarm Set: Output mag handler: Fail to load mag (setup) (U2) Page - 197 - of 321 Sep 18, 2020 Rev 4.1 Kulicke & Soffa™ SECS/GEM Interface for K&S Ball Bonders Bonder software version x-xx-x-472-series IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Collection Events CEID Name Description 10241 MH_FAILED_GET_MAG_OCLEAR Alarm Clear: Output mag handler: Fail to load mag (setup) 10250 MH_STORE_SENSOR_ER ROR-SET Alarm Set: Input mag handler tray full or detect sensor blocked 10251 MH_STORE_SENSOR_ER ROR-CLEAR Alarm Clear: Input mag handler tray full or detect sensor blocked 10260 MH_STORE_SENSOR_ER ROR_O-SET Alarm Set: Output mag handler tray full or detect sensor blocked 10261 MH_STORE_SENSOR_ER ROR_O-CLEAR Alarm Clear: Output mag handler tray full or detect sensor blocked 10270 MH_TRAY_ERROR_IN_LO AD-SET Alarm Set: A magazine was illegally place on the input mag's load tray or it was illegally taken off 10271 MH_TRAY_ERROR_IN_LO AD-CLEAR Alarm Clear: A magazine was illegally place on the input mag's load tray or it was illegally taken off 10280 MH_TRAY_ERROR_IN_UN LOAD-SET Alarm Set: A magazine was illegally place on the Input Mag's unload tray or it was illegally taken off 10281 MH_TRAY_ERROR_IN_UN LOAD-CLEAR Alarm Clear: A magazine was illegally place on the Input Mag's unload tray or it was illegally taken off 10290 MH_TRAY_ERROR_OUT_L OAD-SET Alarm Set: A magazine was illegally place on the Output Mag's load tray or it was illegally taken off 10291 MH_TRAY_ERROR_OUT_L OAD-CLEAR Alarm Clear: A magazine was illegally place on the Output Mag's load tray or it was illegally taken off 10300 MH_TRAY_ERROR_OUT_U NLOAD-SET Alarm Set: A magazine was illegally place on the Output Mag's unload tray or it was illegally taken off 10301 MH_TRAY_ERROR_OUT_U NLOAD-CLEAR Alarm Clear: A magazine was illegally place on the Output Mag's unload tray or it was illegally taken off 10310 MHS_IND_AXIS_LIMIT_ER ROR-SET Alarm Set: Indexer Motion interrupted 10311 MHS_IND_AXIS_LIMIT_ER ROR-CLEAR Alarm Clear: Indexer Motion interrupted 10320 MHS_IND_JAM_RELIEF_E RROR-SET Alarm Set: Jam transducer decompression failure 10321 MHS_IND_JAM_RELIEF_E RROR-CLEAR Alarm Clear: Jam transducer decompression failure 10330 RRL_LIMIT_REACHED_IND EX-SET Alarm Set: Rear rail reached limit during device index 10331 RRL_LIMIT_REACHED_IND EX-CLEAR Alarm Clear: Rear rail reached limit during device index 10340 FRL_LIMIT_REACHED_CO RR-SET Alarm Set: Front rail reached limit during device correction (U2) Page - 198 - of 321 Sep 18, 2020 Rev 4.1 Kulicke & Soffa™ SECS/GEM Interface for K&S Ball Bonders Bonder software version x-xx-x-472-series IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Collection Events CEID Name Description 10341 FRL_LIMIT_REACHED_CO RR-CLEAR Alarm Clear: Front rail reached limit during device correction 10350 RRL_LIMIT_REACHED_CO RR-SET Alarm Set: Rear limit reached limit during device correction 10351 RRL_LIMIT_REACHED_CO RR-CLEAR Alarm Clear: Rear limit reached limit during device correction 10360 FRL_LIMIT_REACHED_CY CLE-SET Alarm Set: Front rail reached limit during cycling 10361 FRL_LIMIT_REACHED_CY CLE-CLEAR Alarm Clear: Front rail reached limit during cycling 10370 RRL_LIMIT_REACHED_CY CLE-SET Alarm Set: Rear rail reached limit during cycling 10371 RRL_LIMIT_REACHED_CY CLE-CLEAR Alarm Clear: Rear rail reached limit during cycling 10380 FRL_WILL_REACH_LIMIT_ SETUP-SET Alarm Set: Front rail will reach limit during setup 10381 FRL_WILL_REACH_LIMIT_ SETUP-CLEAR Alarm Clear: Front rail will reach limit during setup 10390 RRL_WILL_REACH_LIMIT_ SETUP-SET Alarm Set: Rear rail will reach limit during setup 10391 RRL_WILL_REACH_LIMIT_ SETUP-CLEAR Alarm Clear: Rear rail will reach limit during setup 10400 PUL_NOT_OUT_OF_HOME -SET Alarm Set: Puller is not out of home 10401 PUL_NOT_OUT_OF_HOME -CLEAR Alarm Clear: Puller is not out of home 10410 IND_NOT_OUT_OF_HOMESET Alarm Set: Indexer is not out of home 10411 IND_NOT_OUT_OF_HOMECLEAR Alarm Clear: Indexer is not out of home 10420 FRL_NOT_OUT_OF_HOME -SET Alarm Set: Front rail is not out of home 10421 FRL_NOT_OUT_OF_HOME -CLEAR Alarm Clear: Front rail is not out of home 10430 RRL_NOT_OUT_OF_HOME -SET Alarm Set: Rear rail is not out of home 10431 RRL_NOT_OUT_OF_HOME -CLEAR Alarm Clear: Rear rail is not out of home 10440 CI_NOT_OUT_OF_HOMESET Alarm Set: Clamp is not out of home (U2) Page - 199 - of 321 Sep 18, 2020 Rev 4.1 Kulicke & Soffa™ SECS/GEM Interface for K&S Ball Bonders Bonder software version x-xx-x-472-series IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Collection Events CEID Name Description 10441 CI_NOT_OUT_OF_HOMECLEAR Alarm Clear: Clamp is not out of home 10450 HB_NOT_OUT_OF_HOMESET Alarm Set: Heat block is not out of home 10451 HB_NOT_OUT_OF_HOMECLEAR Alarm Clear: Heat block is not out of home 10460 GRP_NOT_OUT_OF_HOM E-SET Alarm Set: Indexer gripper is not out of home 10461 GRP_NOT_OUT_OF_HOM E-CLEAR Alarm Clear: Indexer gripper is not out of home 10470 IND_RECOVERY-SET Alarm Set: Index sequence aborted 10471 IND_RECOVERY-CLEAR Alarm Clear: Index sequence aborted 10480 IND_REMOVE_CRR-SET Alarm Set: Remove leadframe from the rails 10481 IND_REMOVE_CRRCLEAR Alarm Clear: Remove leadframe from the rails 10490 CORR_IFR_WITH_PREBO ND_CRR-SET Alarm Set: Correction will interfere with pre-bond leadframe 10491 CORR_IFR_WITH_PREBO ND_CRR-CLEAR Alarm Clear: Correction will interfere with pre-bond leadframe 10500 RLS_CORRECT_ERRORSET Alarm Set: Rail correction motion error 10501 RLS_CORRECT_ERRORCLEAR Alarm Clear: Rail correction motion error 10510 WHL_HAS_DEVICE_CLAM PED-SET Alarm Set: There is a clamped device present and operation will release this device 10511 WHL_HAS_DEVICE_CLAM PED-CLEAR Alarm Clear: There is a clamped device present and operation will release this device 10520 MH_INIT_CANNOT_STORE _MAGAZINE-SET Alarm Set: Cannot unload magazine so cannot properly complete the init operation 10521 MH_INIT_CANNOT_STORE _MAGAZINE-CLEAR Alarm Clear: Cannot unload magazine so cannot properly complete the init operation 10530 MH_CHESS_TO_SAFE_LO CATION-SET Alarm Set: Lost power fail data must chess out to safe location 10531 MH_CHESS_TO_SAFE_LO CATION-CLEAR Alarm Clear: Lost power fail data must chess out to safe location 10540 MH_DROP_MAGAZINESET Alarm Set: MH magazine will be dropped 10541 MH_DROP_MAGAZINECLEAR Alarm Clear: MH magazine will be dropped (U2) Page - 200 - of 321 Sep 18, 2020 Rev 4.1 Kulicke & Soffa™ SECS/GEM Interface for K&S Ball Bonders Bonder software version x-xx-x-472-series IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Collection Events CEID Name Description 10550 MH_MUST_ALSO_HOME_ Y_MOTOR-SET Alarm Set: Home operation on Input magazine handler will also Home the Y motor since damage to the trays could result otherwise 10551 MH_MUST_ALSO_HOME_ Y_MOTOR-CLEAR Alarm Clear: Home operation on Input magazine handler will also Home the Y motor since damage to the trays could result otherwise 10560 MH_MUST_ALSO_HOME_ Y_MOTOR_O-SET Alarm Set: Home operation on Output magazine handler will also home the Y motor since damage to the trays could result otherwise 10561 MH_MUST_ALSO_HOME_ Y_MOTOR_O-CLEAR Alarm Clear: Home operation on Output magazine handler will also home the Y motor since damage to the trays could result otherwise 10570 MH_HOME_G_MUST_HOM E_Y_MOTOR-SET Alarm Set: Homing the gripper on the Input magazine handler while in the tray area could damage the trays 10571 MH_HOME_G_MUST_HOM E_Y_MOTOR-CLEAR Alarm Clear: Homing the gripper on the Input magazine handler while in the tray area could damage the trays 10580 MH_HOME_G_MUST_HOM E_Y_MOTOR_O-SET Alarm Set: Homing the gripper on the Output magazine handler while in the tray area could damage the trays 10581 MH_HOME_G_MUST_HOM E_Y_MOTOR_O-CLEAR Alarm Clear: Homing the gripper on the Output magazine handler while in the tray area could damage the trays 10590 MH_HOME_G_MUST_HOM E_Z_MOTOR-SET Alarm Set: Homing the gripper motor on the Input magazine handler may damage the handler so must first home the Z motor 10591 MH_HOME_G_MUST_HOM E_Z_MOTOR-CLEAR Alarm Clear: Homing the gripper motor on the Input magazine handler may damage the handler so must first home the Z motor 10600 MH_HOME_G_MUST_HOM E_Z_MOTOR_O-SET Alarm Set: Homing the gripper motor on the Output magazine handler may damage the handler so must first home the Z motor. 10601 MH_HOME_G_MUST_HOM E_Z_MOTOR_O-CLEAR Alarm Clear: Homing the gripper motor on the Output magazine handler may damage the handler so must first home the Z motor. 10610 MH_HOME_GRIPPER_DR OP_MAG-SET Alarm Set: Homing the gripper on the Input magazine handler will drop the magazine 10611 MH_HOME_GRIPPER_DR OP_MAG-CLEAR Alarm Clear: Homing the gripper on the Input magazine handler will drop the magazine 10620 MH_HOME_GRIPPER_DR OP_MAG_O-SET Alarm Set: Homing the gripper on the Output magazine handler will drop the magazine 10621 MH_HOME_GRIPPER_DR OP_MAG_O-CLEAR Alarm Clear: Homing the gripper on the Output magazine handler will drop the magazine 10630 MH_INVALID_GRIP_STATE -SET Alarm Set: Input magazine handler state says gripped yet touch and grip sensor are not both active 10631 MH_INVALID_GRIP_STATE -CLEAR Alarm Clear: Input magazine handler state says gripped yet touch and grip sensor are not both active (U2) Page - 201 - of 321 Sep 18, 2020 Rev 4.1 Kulicke & Soffa™ SECS/GEM Interface for K&S Ball Bonders Bonder software version x-xx-x-472-series IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Collection Events CEID Name Description 10640 MH_INVALID_GRIP_STATE _O-SET Alarm Set: Output magazine handler state says gripped yet touch and grip sensor are not both active 10641 MH_INVALID_GRIP_STATE _O-CLEAR Alarm Clear: Output magazine handler state says gripped yet touch and grip sensor are not both active 10650 MH_INVALID_UNGRIP_ST ATE-SET Alarm Set: Input magazine handler state stays ungripped yet touch and/or grip sensor are active 10651 MH_INVALID_UNGRIP_ST ATE-CLEAR Alarm Clear: Input magazine handler state stays ungripped yet touch and/or grip sensor are active 10660 MH_INVALID_UNGRIP_ST ATE_O-SET Alarm Set: Output magazine handler state stays ungripped yet touch and/or grip sensor are active 10661 MH_INVALID_UNGRIP_ST ATE_O-CLEAR Alarm Clear: Output magazine handler state stays ungripped yet touch and/or grip sensor are active 10670 MH_TRAY_DETECT-SET Alarm Set: Input magazine handler, tray detect sensor active at invalid location, Invalid sensor condition 10671 MH_TRAY_DETECTCLEAR Alarm Clear: Input magazine handler, tray detect sensor active at invalid location, Invalid sensor condition 10680 MH_TRAY_DETECT_OSET Alarm Set: Output magazine handler, tray detect sensor active at invalid location, Invalid sensor condition 10681 MH_TRAY_DETECT_OCLEAR Alarm Clear: Output magazine handler, tray detect sensor active at invalid location, Invalid sensor condition 10690 MH_GRIP_ACTIVE_INVALI D_ABORT-SET Alarm Set: Input mag handler grip sensor blocked 10691 MH_GRIP_ACTIVE_INVALI D_ABORT-CLEAR Alarm Clear: Input mag handler grip sensor blocked 10700 MH_GRIP_ACTIVE_INVALI D_ABORT_O-SET Alarm Set: Output mag handler grip sensor blocked 10701 MH_GRIP_ACTIVE_INVALI D_ABORT_O-CLEAR Alarm Clear: Output mag handler grip sensor blocked 10710 MH_TOUCH_ACTIVE_INVA LID_ABORT-SET Alarm Set: Input mag handler touch sensor blocked 10711 MH_TOUCH_ACTIVE_INVA LID_ABORT-CLEAR Alarm Clear: Input mag handler touch sensor blocked 10730 MH_STATE_BAD_SENSOR S_GRIP_ABORT-SET Alarm Set: Input magazine handler state reports ungripped, and sensors report a magazine is gripped 10731 MH_STATE_BAD_SENSOR S_GRIP_ABORT-CLEAR Alarm Clear: Input magazine handler state reports ungripped, and sensors report a magazine is gripped 10740 MH_STATE_BAD_SENSOR S_GRIP_ABORT_O-SET Alarm Set: Output magazine handler state reports ungripped, and sensors report a magazine is gripped 10741 MH_STATE_BAD_SENSOR S_GRIP_ABORT_O-CLEAR Alarm Clear: Output magazine handler state reports ungripped, and sensors report a magazine is gripped (U2) Page - 202 - of 321 Sep 18, 2020 Rev 4.1 Kulicke & Soffa™ SECS/GEM Interface for K&S Ball Bonders Bonder software version x-xx-x-472-series IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Collection Events CEID Name Description 10750 MH_OP_SUSPEND-SET Alarm Set: Input mag handler: Operation Suspended 10751 MH_OP_SUSPEND-CLEAR Alarm Clear: Input mag handler: Operation Suspended 10760 MH_OP_SUSPEND_O-SET Alarm Set: Output mag handler: Operation Suspended 10761 MH_OP_SUSPEND_OCLEAR Alarm Clear: Output mag handler: Operation Suspended 10770 MH_I_OP_WARN-SET Alarm Set: Input mag handler: Mag Interference Possible 10771 MH_I_OP_WARN-CLEAR Alarm Clear: Input mag handler: Mag Interference Possible 10780 MH_O_OP_WARN-SET Alarm Set: Output mag handler: Mag Interference Possible 10781 MH_O_OP_WARN-CLEAR Alarm Clear: Output mag handler: Mag Interference Possible 10790 MH_TEACH_TOO_MUCH_ ROTATION-SET Alarm Set: Too much rotation found when teaching magazine 10791 MH_TEACH_TOO_MUCH_ ROTAION-CLEAR Alarm Clear: Too much rotation found when teaching magazine 10800 MH_TEACH_OPERATION_ FAILED-SET Alarm Set: Teach operation failed 10801 MH_TEACH_OPERATION_ FAILED-CLEAR Alarm Clear: Teach operation failed 10810 MH_CAL_SLOT_OPERATI ON_FAILED-SET Alarm Set: Calibrate slot operation failed 10811 MH_CAL_SLOT_OPERATI ON_FAILED-CLEAR Alarm Clear: Calibrate slot operation failed 10820 MH_CAL_TRAY_OPERATI ON_FAILED-SET Alarm Set: Calibrate tray operation failed 10821 MH_CAL_TRAY_OPERATI ON_FAILED-CLEAR Alarm Clear: Calibrate tray operation failed 10830 IND_THETA_EXTEND_FAIL URE-SET Alarm Set: Theta bar not extended due to indexer's position 10831 IND_THETA_EXTEND_FAIL URE-CLEAR Alarm Clear: Theta bar not extended due to indexer's position 10840 MHS_JDC_CMD_FAILURESET Alarm Set: Jam Detect command failed 10841 MHS_JDC_CMD_FAILURECLEAR Alarm Clear: Jam Detect command failed 10850 MHS_JDC_DIAG_FAILURESET Alarm Set: Jam Detect diagnostic failed - do calibration 10851 MHS_JDC_DIAG_FAILURECLEAR Alarm Clear: Jam Detect diagnostic failed - do calibration 10860 MHS_JDC_INIT_FAILURESET Alarm Set: Work holder JDC cross load failed (U2) Page - 203 - of 321 Sep 18, 2020 Rev 4.1 Kulicke & Soffa™ SECS/GEM Interface for K&S Ball Bonders Bonder software version x-xx-x-472-series IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Collection Events CEID Name Description 10861 MHS_JDC_INIT_FAILURECLEAR Alarm Clear: Work holder JDC cross load failed 10870 PUL_Y_REGISTRATION_F AILURE-SET Alarm Set: Lead frame's Y registration edge not found 10871 PUL_Y_REGISTRATION_F AILURE-CLEAR Alarm Clear: Lead frame's Y registration edge not found 10880 PUL_CARRIER_MISSINGSET Alarm Set: leadframe is not present on the work holder 10881 PUL_CARRIER_MISSINGCLEAR Alarm Clear: leadframe is not present on the work holder 10890 PUL_Y_REGISTRATION_A CTIVE-SET Alarm Set: Y registration sensor is already blocked 10891 PUL_Y_REGISTRATION_A CTIVE-CLEAR Alarm Clear: Y registration sensor is already blocked 10900 MHS_INDEXER_CALIBRAT ION_UNSUCCESSFUL-SET Alarm Set: Indexer calibration terminated 10901 MHS_INDEXER_CALIBRAT ION_UNSUCCESSFULCLEAR Alarm Clear: Indexer calibration terminated 10910 MHS_CLAMP_CALIBRATIO N_UNSUCCESSFUL-SET Alarm Set: Clamp calibration terminated 10911 MHS_CLAMP_CALIBRATIO N_UNSUCCESSFULCLEAR Alarm Clear: Clamp calibration terminated 10920 MHS_RAILS_CALIBRATION _UNSUCCESSFUL-SET Alarm Set: Rails calibration terminated 10921 MHS_RAILS_CALIBRATION _UNSUCCESSFUL-CLEAR Alarm Clear: Rails calibration terminated 10930 MHS_X_SENSOR_CALIBR ATION_UNSUCCESSFULSET Alarm Set: Work holder X sensor calibration terminated 10931 MHS_X_SENSOR_CALIBR ATION_UNSUCCESSFULCLEAR Alarm Clear: Work holder X sensor calibration terminated 10940 MHS_CAL_TUCKER_EJEC T_OPERATION_FAILEDSET Alarm Set: Indexer tucker eject calibration terminated 10941 MHS_CAL_TUCKER_EJEC T_OPERATION_FAILEDCLEAR Alarm Clear: Indexer tucker eject calibration terminated 10950 MHS_JAM_CALIBRATION_ UNSUCCESSFUL-SET Alarm Set: Jam detect calibration terminated (U2) Page - 204 - of 321 Sep 18, 2020 Rev 4.1 Kulicke & Soffa™ SECS/GEM Interface for K&S Ball Bonders Bonder software version x-xx-x-472-series IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Collection Events CEID Name Description 10951 MHS_JAM_CALIBRATION_ UNSUCCESSFUL-CLEAR Alarm Clear: Jam detect calibration terminated 10960 MHS_IN_BCR_FAIL-SET Alarm Set:Input Magazine Barcode read fail 10961 MHS_IN_BCR_FAIL-CLEAR Alarm Clear: Input Magazine Barcode read fail 10970 MHS_OUT_BCR_FAIL-SET Alarm Set:Output Magazine Barcode read fail 10971 MHS_OUT_BCR_FAILCLEAR Alarm Clear: Output Magazine Barcode read fail 10980 AUTO_INVALID_MAG-SET Alarm Set:Invalid Magazine 10981 AUTO_INVALID_MAGCLEAR Alarm Clear: Invalid Magazine 10990 PBI-UNIT-STOP-ERR-SET Alarm set: out of tolerance detected during Post Bond Inspection. 10991 PBI-UNIT-STOP-ERRCLEAR Alarm clear: out of tolerance detected during Post Bond Inspection. 11000 AUTO-LEAD-BPC-ERR-SET Alarm set: Bond proximity check failed 11001 AUTO_LEAD_BPC_ERROR -CLEAR Alarm clear: Bond proximity check cleared 11010 AUTO-USG-IMPEDANCECAL-FAIL-SET Alarm set: AUTO-USG-IMPEDANCE-CAL-FAIL 11011 AUTO-USG-IMPEDANCECAL-FAIL-CLEAR Alarm clear: AUTO-USG-IMPEDANCE-CAL-FAIL 11020 AUTO-USG-IMPEDANCEOUT-LIMIT-SET Alarm set: AUTO-USG-IMPEDANCE-OUT-LIMIT 11021 AUTO-USG-IMPEDANCEOUT-LIMIT-CLEAR Alarm clear:AUTO-USG-IMPEDANCE-OUT-LIMIT 11040 TEMPERATURE_AUTO_TU NE_FAIL-SET Alarm set: Auto tuning of the heat block temperature failure 11041 TEMPERATURE_AUTO_TU NE_FAIL_CLEAR Alarm clear: Auto tuning of the heat block temperature failure 11050 AUTO-CU-COVER-GASPRESSURE-OUT-LIMITSET Alarm set: Nitrogen gas flow out of tolerance 11051 AUTO-CU-COVER-GASPRESSURE-OUT-LIMITCLEAR Alarm clear: Nitrogen gas flow out of tolerance 11060 X_Y_TABLE_LIMITS-SET Alarm set: X or Y table limits are unacceptable 11061 X_Y_TABLE_LIMITSCLEAR Alarm clear: X or Y table limits are unacceptable 11070 AUTO-VLL-FM-DETECTEDSET Alarm set: Auto VLL foreign material detected (U2) Page - 205 - of 321 Sep 18, 2020 Rev 4.1 Kulicke & Soffa™ SECS/GEM Interface for K&S Ball Bonders Bonder software version x-xx-x-472-series IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Collection Events CEID Name Description 11071 AUTO-VLL-FM-DETECTEDCLEAR Alarm clear: Auto VLL foreign material detected 11080 AUTO-OVERLAPPED-DIESSET Alarm set: There are overlapped dies 11081 AUTO-OVERLAPPED-DIESCLEAR Alarm clear: There are overlapped dies 11090 AUTO-ALIGN-REFDRIFTFAIL-SET Alarm set: AUTO-ALIGN-REFDRIFT-FAIL. 11091 AUTO-ALIGN-REFDRIFTFAIL-Clear Alarm clear: AUTO-ALIGN-REFDRIFT-FAIL. 11100 AUTO_BOND_COUNT_RE ACHING_LIMIT_Set Alarm set: AUTO_BOND_COUNT_REACHING_LIMIT. 11101 AUTO_BOND_COUNT_RE ACHING_LIMIT_Clear Alarm clear: AUTO_BOND_COUNT_REACHING_LIMIT. 11110 AUTO_BOND_COUNT_RE ACHING_LIMIT_NOWAIT_S et Alarm set: AUTO_BOND_COUNT_REACHING_LIMIT_NOWAIT 11111 AUTO_BOND_COUNT_RE ACHING_LIMIT_NOWAIT_C lear Alarm clear: AUTO_BOND_COUNT_REACHING_LIMIT_NOWAIT 11120 PDT-BONDHEIGHTERROR-Set Alarm set: PDT-BONDHEIGHT-ERROR. 11121 PDT-BONDHEIGHTERROR-Clear Alarm clear: PDT-BONDHEIGHT-ERROR. 11130 ZTC-OUT-OF-LIMITS-Set Alarm set: ZTC-OUT-OF-LIMITS. 11131 ZTC-OUT-OF-LIMITS-Clear Alarm clear: ZTC-OUT-OF-LIMITS. 11150 CAP_CLEAN_TAPE_USAG E_EXCEED_LIMIT-SET Alarm set: CAP_CLEAN_TAPE_USAGE_EXCEED_LIMIT. 11151 CAP_CLEAN_TAPE_USAG E_EXCEED_LIMIT-ClEAR Alarm clear: CAP_CLEAN_TAPE_USAGE_EXCEED_LIMIT. 11160 EH-PDT-SMBALL-SET Alarm Set: PDT Small Ball Set 11161 EH-PDT-SMBALL-CLEAR Alarm Clear: PDT Small Ball Clear 11170 PDT-UNEXPECTED-NSOPTOL-SET Alarm Set: PDT Unexpected NSOP TOL Set 11171 PDT-UNEXPECTED-NSOPTOL-CLEAR Alarm Clear: PDT Unexpected NSOP TOL Clear 11180 PBI-REALIGN-FAILURESET Alarm Set: PBI Realign Failure Set 11181 PBI-REALIGN-FAILURECLEAR Alarm Clear: PBI Realign Failure Clear (U2) Page - 206 - of 321 Sep 18, 2020 Rev 4.1 Kulicke & Soffa™ SECS/GEM Interface for K&S Ball Bonders Bonder software version x-xx-x-472-series IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Collection Events CEID Name Description 11190 CAP_CLEANING_LIMIT_EX CEEDED-SET Alarm Set: Set Cap Clean Exceeded Limit 11191 CAP_CLEANING_LIMIT_EX CEEDED-CLEAR Alarm Clear: Clear Cap Clean Exceeded Limit 11200 BONDSITE_CHKSUM_FAIL -SET Alarm Set: Bond Site Check Sum Fail Set 11201 BONDSITE_CHKSUM_FAIL -CLEAR Alarm Clear: Bond Site Check Sum Failure Clear 11210 REF_SYS_XHAIR_OFFSET _FAIL-SET Alarm Set: Ref Sys Xhair Offset Fail 11211 REF_SYS_XHAIR_OFFSET _FAIL-CLEAR Alarm Clear: Ref Sys Xhair Offset Fail 11220 MH_WAIT_GET_MAG-SET Alarm Set: MH Wait Get Mag 11221 MH_WAIT_GET_MAGCLEAR Alarm Clear: MH Wait Ge Mag 11230 MH_WAIT_GET_MAG_OSET Alarm Set: MH Wait Get Mag Output 11231 MH_WAIT_GET_MAG_OCLEAR Alarm Clear: MH Wait Get Mag Output 11240 STRIP_ID_NOT_FOUNDSET Alarm Set: Strip ID Not Found 11241 STRIP_ID_NOT_FOUNDCLEAR Alarm Clear: Strip ID Not Found 11250 MH_WT_HOST_RETRY_XC EED-SET Alarm Set: MH_WT_HOST_RETRY_XCEED 11251 MH_WT_HOST_RETRY_XC EED-CLEAR Alarm Clear: MH_WT_HOST_RETRY_XCEED 11260 MH_WT_HOST_RETRY_XC EED_O-SET Alarm Set: MH_WT_HOST_RETRY_XCEED_O 11261 MH_WT_HOST_RETRY_XC EED_O-CLEAR Alarm Clear: MH_WT_HOST_RETRY_XCEED_O 11270 EH_SUB_VALIDATION_TIM EOUT-SET Alarm Set: EH_SUB_VALIDATION_TIMEOUT 11271 EH_SUB_VALIDATION_TIM EOUT-CLEAR Alarm Clear: EH_SUB_VALIDATION_TIMEOUT 11280 MHS_IN_BCR_REJECT_ER ROR-SET Alarm Set: MHS_IN_BCR_REJECT_ERROR 11281 MHS_IN_BCR_REJECT_ER ROR-CLEAR Alarm Clear: MHS_IN_BCR_REJECT_ERROR (U2) Page - 207 - of 321 Sep 18, 2020 Rev 4.1 Kulicke & Soffa™ SECS/GEM Interface for K&S Ball Bonders Bonder software version x-xx-x-472-series IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Collection Events CEID Name Description 11290 MHS_OUT_BCR_REJECT_ ERROR-SET Alarm Set: MHS_OUT_BCR_REJECT_ERROR 11291 MHS_OUT_BCR_REJECT_ ERROR-CLEAR Alarm Clear: MHS_OUT_BCR_REJECT_ERROR 11300 EH_SUB_VALIDATION_RE JECTED-SET Alarm Set: EH_SUB_VALIDATION_REJECTED 11301 EH_SUB_VALIDATION_RE JECTED-CLEAR Alarm Clear: EH_SUB_VALIDATION_REJECTED 11310 EH_EVENT_COUNT_THRE SHOLD_EXCEEDED-SET Alarm Set: EH_EVENT_COUNT_THRESHOLD_EXCEEDED 11311 EH_EVENT_COUNT_THRE SHOLD_EXCEEDEDCLEAR Alarm Clear: EH_EVENT_COUNT_THRESHOLD_EXCEEDED 11320 AUTO_USG_LOCK_FREQ_ DRIFT-SET Alarm Set: Auto USG Lock FREQ Drift 11321 AUTO_USG_LOCK_FREQ_ DRIFT-CLEAR Alarm clear: Auto USG Lock FREQ Drift 11330 EH_EVENT_COUNT_STOP _AUTO-SET Alarm Set: EH Event Count Stop Auto 11331 EH_EVENT_COUNT_STOP _AUTO-CLEAR Alarm clear: EH Event Count Stop Auto 11340 PDT-MOTION-TIMEOUTSET Alarm Set: PDT Motion Time Out 11341 PDT-MOTION-TIMEOUTCLEAR Alarm clear: PDT Motion Time Out 11350 PDT-AWAIT-TIMEOUT-SET Alarm Set: PDT Await Time Out 11351 PDT-AWAIT-TIMEOUTCLEAR Alarm clear: PDT Await Time Out 11360 PDT-CALLBACKREGISTRATION-SET Alarm Set: PDT Callback Registration 11361 PDT-CALLBACKREGISTRATION-CLEAR Alarm clear: PDT Callback Registration 11370 WARNING_EFO_NOT_HAZ ARD-SET Alarm Set: Warning EFO Not Hazard 11371 WARNING_EFO_NOT_HAZ ARD-CLEAR Alarm clear: Warning EFO Not Hazard 11380 PDT-EFO-INVALID-DATASET Alarm Set: PDT EFO Invalid Data 11381 PDT-EFO-INVALID-DATACLEAR Alarm clear: PDT EFO Invalid Data (U2) Page - 208 - of 321 Sep 18, 2020 Rev 4.1 Kulicke & Soffa™ SECS/GEM Interface for K&S Ball Bonders Bonder software version x-xx-x-472-series IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Collection Events CEID Name Description 11390 EH-PDT-BUMP-LIFT-SET Alarm Set: EH PDT Bump Lift 11391 EH-PDT-BUMP-LIFTCLEAR Alarm clear: EH PDT Bump Lift 11400 EFO-BOX-COM-ERRORSET Alarm Set: EFO Box COM Error 11401 EFO-BOX-COM-ERRORCLEAR Alarm clear: EFO Box COM Error 11410 EFO-RESOURCE-NOTAVAILABLE-SET Alarm Set: EFO Resource Not Available 11411 EFO-RESOURCE-NOTAVAILABLE-CLEAR Alarm clear: EFO Resource Not Available 11420 PDT-NO-TIMERS-SET Alarm Set: PDT No Timers 11421 PDT-NO-TIMERS-CLEAR Alarm clear: PDT No Timers 11430 PDT-NO-FS-DETECT-SET Alarm Set: PDT No FS Detect 11431 PDT-NO-FS-DETECTCLEAR Alarm clear: PDT No FS Detect 11440 PDT-BITS-CAL-ERRORSET Alarm Set: PDT BITS Cal Error 11441 PDT-BITS-CAL-ERRORCLEAR Alarm clear: PDT BITS Cal Error 11450 PDT-DIE-MISSING-SET Alarm Set: PDT Die Missing 11451 PDT-DIE-MISSING-CLEAR Alarm clear: PDT Die Missing 11460 PDT-UNEXPECTED-LGTLSET Alarm Set: PDT Unexpected LGTL 11461 PDT-UNEXPECTED-LGTLCLEAR Alarm clear: PDT Unexpected LGTL 11470 PDT-UNEXPECTED-NSOPBY-PRS-SET Alarm Set: PDT Unexpected NSOP By PRS 11471 PDT-UNEXPECTED-NSOPBY-PRS-CLEAR Alarm clear: PDT Unexpected NSOP By PRS 11480 MANUAL-UNEXPECTEDNSOP-SET Alarm Set: Manual Unexpected NSOP 11481 MANUAL-UNEXPECTEDNSOP-CLEAR Alarm clear: Manual Unexpected NSOP 11490 MANUAL-UNEXPECTEDNSOL-SET Alarm Set: Manual Unexpected NSOL 11491 MANUAL-UNEXPECTEDNSOL-CLEAR Alarm clear: Manual Unexpected NSOL (U2) Page - 209 - of 321 Sep 18, 2020 Rev 4.1 Kulicke & Soffa™ SECS/GEM Interface for K&S Ball Bonders Bonder software version x-xx-x-472-series IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Collection Events CEID Name Description 11500 MANUAL-UNEXPECTEDSHTL-SET Alarm Set: Manual Unexpected SHTL 11501 MANUAL-UNEXPECTEDSHTL-CLEAR Alarm clear: Manual Unexpected SHTL 11510 MANUAL-WIREFEEDERROR-SET Alarm Set: Manual Wirefeed Error 11511 MANUAL-WIREFEEDERROR-CLEAR Alarm clear: Manual Wirefeed Error 11520 MANUAL-EFO-INVALIDDATA-SET Alarm Set: Manual EFO Invalid Data 11521 MANUAL-EFO-INVALIDDATA-CLEAR Alarm clear: Manual EFO Invalid Data 11530 EFO-CLEAN-SET Alarm Set: EFO Clean 11531 EFO-CLEAN-CLEAR Alarm clear: EFO Clean 11540 MANUAL-UNEXPECTEDLGTL-SET Alarm Set: Manual Unexcepted LGTL 11541 MANUAL-UNEXPECTEDLGTL-CLEAR Alarm clear: Manual Unexcepted LGTL 11550 CAP-UNCLOG-SET Alarm Set: Cap UNCLOG 11551 CAP-UNCLOG-CLEAR Alarm clear: Cap UNCLOG 11560 EH_AUTO_RECV_REPLAC E_BOFF_PLATE-SET Alarm Set: EH Auto Recive Replace BOFF Plate 11561 EH_AUTO_RECV_REPLAC E_BOFF_PLATE-CLEAR Alarm clear: EH Auto Recive Replace BOFF Plate 11570 AUTO-USG-LOCK-DRIFTSET Alarm Set: Auto USG Lock Drift 11571 AUTO-USG-LOCK-DRIFTCLEAR Alarm clear: Auto USG Lock Drift 11580 AUTO-EMS-LOW-SET Alarm Set: Auto EMS Low 11581 AUTO-EMS-LOW-CLEAR Alarm clear: Auto EMS Low 11590 AUTO-ALIGN-FATAL-SET Alarm Set: Auto Align Fatal 11591 AUTO-ALIGN-FATALCLEAR Alarm clear: Auto Align Fatal 11600 AUTO-ALIGN-MOT-FAILSET Alarm Set: Auto Align Mot Fail 11601 AUTO-ALIGN-MOT-FAILCLEAR Alarm clear: Auto Align Mot Fail 11610 AUTO-ALIGN-PRS-FAILSET Alarm Set: Auto Align PRS Fail (U2) Page - 210 - of 321 Sep 18, 2020 Rev 4.1 Kulicke & Soffa™ SECS/GEM Interface for K&S Ball Bonders Bonder software version x-xx-x-472-series IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Collection Events CEID Name Description 11611 AUTO-ALIGN-PRS-FAILCLEAR Alarm clear: Auto Align PRS Fail 11620 AUTO-ALIGN-VLL-FAILSET Alarm Set: Auto Align VLL Fail 11621 AUTO-ALIGN-VLL-FAILCLEAR Alarm clear: Auto Align VLL Fail 11630 AUTO-UPDATE-AWAITTIMEOUT-SET Alarm Set: Auto Update Await Time Out 11631 AUTO-UPDATE-AWAITTIMEOUT-CLEAR Alarm clear: Auto Update Await Time Out 11640 AUTO-BAD-START-SET Alarm Set: Auto Bad Start 11641 AUTO-BAD-START-CLEAR Alarm clear: Auto Bad Start 11650 AUTO-REJECTEYESKIPPARMS-EXCEEDEDSET Alarm Set: Auto Reject Eye Skip Parameters Exceeded 11651 AUTO-REJECTEYESKIPPARMS-EXCEEDEDCLEAR Alarm clear: Auto Reject Eye Skip Parameters Exceeded 11660 AUTO-ZPROBESKIPPARMS-EXCEEDEDSET Alarm Set: Auto ZPROBE Skip Parameters Exceeded 11661 AUTO-ZPROBESKIPPARMS-EXCEEDEDCLEAR Alarm clear: Auto ZPROBE Skip Parameters Exceeded 11670 AUTO-LARGE-DRIFTERROR-SET Alarm Set: Auto Large Drift Error 11671 AUTO-LARGE-DRIFTERROR-CLEAR Alarm clear: Auto Large Drift Error 11680 FAILED-CAPILLARY-FINDSET Alarm Set: Failed Capillary Find 11681 FAILED-CAPILLARY-FINDCLEAR Alarm clear: Failed Capillary Find 11690 MLO-EXCESS-CHG-STOPSET Alarm Set: MLO Excess CHG Stop 11691 MLO-EXCESS-CHG-STOPCLEAR Alarm clear: MLO Excess CHG Stop 11700 BOFF-AREA-FULL-SET Alarm Set: BOFF Area Full 11701 BOFF-AREA-FULL-CLEAR Alarm clear: BOFF Area Full 11710 AUTO-NEARING-TOOLUSAGE-LIMIT-SET Alarm Set: Auto Nearing Tool Usage Limit (U2) Page - 211 - of 321 Sep 18, 2020 Rev 4.1 Kulicke & Soffa™ SECS/GEM Interface for K&S Ball Bonders Bonder software version x-xx-x-472-series IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Collection Events CEID Name Description 11711 AUTO-NEARING-TOOLUSAGE-LIMIT-CLEAR Alarm Set: Auto Nearing Tool Usage Limit 11720 AUTO-BONDHEAD-TABLEVIOLATION-NOWAIT-SET Alarm Set: Auto Bondhead Table Violation No Wait 11721 AUTO-BONDHEAD-TABLEVIOLATION-NOWAITCLEAR Alarm clear: Auto Bondhead Table Violation No Wait 11730 AUTO-CONF-BPC-ERRSET Alarm Set: Auto Configure BPC Error 11731 AUTO-CONF-BPC-ERRCLEAR Alarm clear: Auto Configure BPC Error 11740 AUTO-BITS-CFG-XMATCHSWDC-HWAC-SET Alarm Set: Auto BITS Configure XMatch SWDCHWAC 11741 AUTO-BITS-CFG-XMATCHSWDC-HWAC-CLEAR Alarm clear: Auto BITS Configure XMatch SWDCHWAC 11750 AUTO-BITS-CFG-XMATCHSWAC-HWDC-SET Alarm Set: Auto BITS Configure XMatch SWACHWDC 11751 AUTO-BITS-CFG-XMATCHSWAC-HWDC-CLEAR Alarm clear: Auto BITS Configure XMatch SWACHWDC 11760 AUTO-PRE-BOND-CHECKSET Alarm Set: Auto PRE Bond Check 11761 AUTO-PRE-BOND-CHECKCLEAR Alarm clear: Auto PRE Bond Check 11770 MC_IDLE_TOO_LONG-SET Alarm Set: MC Idle Too Long 11771 MC_IDLE_TOO_LONGCLEAR Alarm clear: MC Idle Too Long 11780 AUTO-WIRE-USAGETHRESHOLD-EXCEEDEDSET Alarm Set: Auto Wire Usage Threshold Exceeded 11781 AUTO-WIRE-USAGETHRESHOLD-EXCEEDEDCLEAR Alarm clear: Auto Wire Usage Threshold Exceeded 11790 AUTO-TOOL-USAGE-LIMITEXCEEDED-NOWAIT-SET Alarm Set: Auto Tool Usage Limit Exceeded No Wait 11791 AUTO-TOOL-USAGE-LIMITEXCEEDED-NOWAITCLEAR Alarm clear: Auto Tool Usage Limit Exceeded No Wait 11800 AUTO-MHS-CLAMP-OPENSET Alarm Set: Auto MHS Clamp Open 11801 AUTO-MHS-CLAMP-OPENCLEAR Alarm clear: Auto MHS Clamp Open (U2) Page - 212 - of 321 Sep 18, 2020 Rev 4.1 Kulicke & Soffa™ SECS/GEM Interface for K&S Ball Bonders Bonder software version x-xx-x-472-series IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Collection Events CEID Name Description 11810 ZTC-AD-RANGE-ERRORSET Alarm Set: ZTC AD Range Error 11811 ZTC-AD-RANGE-ERRORCLEAR Alarm clear:ZTC AD Range Error 11820 AUTO-TEMP-OUT-OFRANGE-OPTICS-SET Alarm Set: Auto Temp Out Of Range Optics 11821 AUTO-TEMP-OUT-OFRANGE-OPTICS-CLEAR Alarm clear: Auto Temp Out Of Range Optics 11830 ZPROTECT-HI-ALARM-SET Alarm Set: ZPROTECT HI Alarm 11831 ZPROTECT-HI-ALARMCLEAR Alarm clear: ZPROTECT HI Alarm 11840 ZPROTECT-OPENSENSOR-SET Alarm Set: ZPROTECT Open Sensor 11841 ZPROTECT-OPENSENSOR-CLEAR Alarm clear: ZPROTECT Open Sensor 11850 AUTO-ALIGN-PAD-FAILSET Alarm Set: Auto Align Pad Fail 11851 AUTO-ALIGN-PAD-FAILCLEAR Alarm clear: Auto Align Pad Fail 11860 AUTO-TEMP-CTRL-COMMFAIL-SET Alarm Set: Auto Temp CTRL COMM Fail 11861 AUTO-TEMP-CTRL-COMMFAIL-CLEAR Alarm clear: Auto Temp CTRL COMM Fail 11870 OPERATOR-ERROR-SET Alarm Set: Operator Error 11871 OPERATOR-ERRORCLEAR Alarm clear: Operator Error 11880 AUTO-MATROX-E-DRIVEFULL-SET Alarm Set: Auto Matrox E Drive Full 11881 AUTO-MATROX-E-DRIVEFULL-CLEAR Alarm clear: Auto Matrox E Drive Full 11890 AUTO-EFO-LIMITEXCEEDED-SET Alarm Set: Auto EFO Limit Exceeded 11891 AUTO-EFO-LIMITEXCEEDED-CLEAR Alarm clear: Auto EFO Limit Exceeded 11900 AUTO-EFO-START-CLEANSET Alarm Set: Auto EFO Start Clean 11901 AUTO-EFO-START-CLEANCLEAR Alarm clear: Auto EFO Start Clean 11910 AUTO_EFOPM_LIMIT_EXC EEDED-SET Alarm Set: Auto EFOPM Limit Exceeded (U2) Page - 213 - of 321 Sep 18, 2020 Rev 4.1 Kulicke & Soffa™ SECS/GEM Interface for K&S Ball Bonders Bonder software version x-xx-x-472-series IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Collection Events CEID Name Description 11911 AUTO_EFOPM_LIMIT_EXC EEDED-CLEAR Alarm clear: Auto EFOPM Limit Exceeded 11920 TEST-ERROR-SET Alarm Set: Test Error 11921 TEST-ERROR-CLEAR Alarm clear: Test Error 11930 MHS_UNDEFINED_CMDSET Alarm Set: MHS Undefined CMD 11931 MHS_UNDEFINED_CMDCLEAR Alarm clear: MHS Undefined CMD 11940 MHS_DISABLED_ACTIVE_ CMD-SET Alarm Set: MHS Disabled Active Command 11941 MHS_DISABLED_ACTIVE_ CMD-CLEAR Alarm clear: MHS Disabled Active Command 11950 MHS_UNAVAILABLE_CMD _RESOURCES-SET Alarm Set: MHS Unavailable Command Resources 11951 MHS_UNAVAILABLE_CMD _RESOURCES-CLEAR Alarm clear: MHS Unavailable Command Resources 11960 MHS_LOGIC_ERROR-SET Alarm Set: MHS Logic Error 11961 MHS_LOGIC_ERRORCLEAR Alarm clear: MHS Logic Error 11970 MHS_ALREADY_ACTIVE_C MD-SET Alarm Set: MHS Already Active Command 11971 MHS_ALREADY_ACTIVE_C MD-CLEAR Alarm clear: MHS Already Active Command 11980 MHS_MSG_QUEUE_OVER FLOW-SET Alarm Set: MHS MSG Queue Overflow 11981 MHS_MSG_QUEUE_OVER FLOW-CLEAR Alarm clear: MHS MSG Queue Overflow 11990 MHS_DYNAMIC_LOAD_ER ROR-SET Alarm Set: MHS Dynamic Load Error 11991 MHS_DYNAMIC_LOAD_ER ROR-CLEAR Alarm clear: MHS Dynamic Load Error 12000 MHS_CONFIRM_CMD_RES OURCES-SET Alarm Set: MHS Confirm CMD Resources 12001 MHS_CONFIRM_CMD_RES OURCES-CLEAR Alarm clear: MHS Confirm CMD Resources 12010 MHS_LOGIC_ERROR_NO_ BLOCK-SET Alarm Set: MHS Logic Error No Block 12011 MHS_LOGIC_ERROR_NO_ BLOCK-CLEAR Alarm clear: MHS Logic Error No Block (U2) Page - 214 - of 321 Sep 18, 2020 Rev 4.1 Kulicke & Soffa™ SECS/GEM Interface for K&S Ball Bonders Bonder software version x-xx-x-472-series IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Collection Events CEID Name Description 12020 PUL_CARRIER_ALREADY_ PRESENT-SET Alarm Set: Pul Carrier Already Present 12021 PUL_CARRIER_ALREADY_ PRESENT-CLEAR Alarm clear: Pul Carrier Already Present 12030 MH_LOGIC_ERROR-SET Alarm Set: MH Logic Error 12031 MH_LOGIC_ERRORCLEAR Alarm clear: MH Logic Error 12040 MH_SETUP_ERROR-SET Alarm Set: MH Setup Error 12041 MH_SETUP_ERRORCLEAR Alarm clear: MH Setup Error 12050 MH_CREATE_ERROR-SET Alarm Set: MH Create Error 12051 MH_CREATE_ERRORCLEAR Alarm clear: MH Create Error 12060 MH_SEND_ERROR-SET Alarm Set: MH Send Error 12061 MH_SEND_ERROR-CLEAR Alarm clear: MH Send Error 12070 MH_RX_ERROR-SET Alarm Set: MH RX Error 12071 MH_RX_ERROR-CLEAR Alarm clear: MH RX Error 12080 MH_CHUTE_EMPTY-SET Alarm Set: MH Chute Empty 12081 MH_CHUTE_EMPTYCLEAR Alarm clear: MH Chute Empty 12090 MH_CHUTE_EMPTY_OSET Alarm Set: MH Chute Empty O 12091 MH_CHUTE_EMPTY_OCLEAR Alarm clear: MH Chute Empty O 12100 MH_BAD_GRIPPER_SIZESET Alarm Set: MH Bad Gripper Size 12101 MH_BAD_GRIPPER_SIZECLEAR Alarm clear: MH Bad Gripper Size 12110 MH_BAD_GRIPPER_SIZE_ O-SET Alarm Set: MH Bad Gripper Size O 12111 MH_BAD_GRIPPER_SIZE_ O-CLEAR Alarm clear: MH Bad Gripper Size O 12120 MH_BAD_GRIPPER_CHAN GE_O-SET Alarm Set: MH Bad Gripper Change O 12121 MH_BAD_GRIPPER_CHAN GE_O-CLEAR Alarm clear: MH Bad Gripper Change O 12130 MH_TRAY_DETECT_SENS OR_FAILURE_O-SET Alarm Set: MH Tray Detect Sensor Failure O (U2) Page - 215 - of 321 Sep 18, 2020 Rev 4.1 Kulicke & Soffa™ SECS/GEM Interface for K&S Ball Bonders Bonder software version x-xx-x-472-series IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Collection Events CEID Name Description 12131 MH_TRAY_DETECT_SENS OR_FAILURE_O-CLEAR Alarm clear: MH Tray Detect Sensor Failure O 12140 MH_MAG_IFR-SET Alarm Set: MH Mag IFR 12141 MH_MAG_IFR-CLEAR Alarm clear: MH Mag IFR 12150 MH_MAG_IFR_O-SET Alarm Set: MH Mag IFR O 12151 MH_MAG_IFR_O-CLEAR Alarm clear: MH Mag IFR O 12160 MH_PUSHER_NOT_RETRA CT-SET Alarm Set: MH Pusher Not Retract 12161 MH_PUSHER_NOT_RETRA CT-CLEAR Alarm clear: MH Pusher Not Retract 12170 MH_PUSHER_NOT_RETRA CT_0-SET Alarm Set: MH Pusher Not Retract O 12171 MH_PUSHER_NOT_RETRA CT_0-CLEAR Alarm clear: MH Pusher Not Retract O 12180 MH_PUSHER_NOT_OUTSET Alarm Set: MH Pusher Not Out 12181 MH_PUSHER_NOT_OUTCLEAR Alarm clear: MH Pusher Not Out 12190 MH_PUSHER_NOT_OUT_0 -SET Alarm Set: MH Pusher Not Out O 12191 MH_PUSHER_NOT_OUT_0 -CLEAR Alarm clear: MH Pusher Not Out O 12200 MH_MAG_IN_LOAD_NEWSET Alarm Set: MH Mag IN Load New 12201 MH_MAG_IN_LOAD_NEWCLEAR Alarm clear: MH Mag IN Load New 12210 MH_MAG_OUT_LOAD_NE W-SET Alarm Set: MH Mag Out Load New 12211 MH_MAG_OUT_LOAD_NE W-CLEAR Alarm clear: MH Mag Out Load New 12220 MH_STANDBY_MAG_NOT_ READY-SET Alarm Set: MH Standby Mag Not Ready 12221 MH_STANDBY_MAG_NOT_ READY-CLEAR Alarm clear: MH Standby Mag Not Ready 12230 MH_STANDBY_MAG_NOT_ READY_O-SET Alarm Set: MH Standby May Not Ready O 12231 MH_STANDBY_MAG_NOT_ READY_O-CLEAR Alarm clear: MH Standby May Not Ready O 12240 MH_TRAY_FULL_DETECTSET Alarm Set: MH Tray Full Detect (U2) Page - 216 - of 321 Sep 18, 2020 Rev 4.1 Kulicke & Soffa™ SECS/GEM Interface for K&S Ball Bonders Bonder software version x-xx-x-472-series IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Collection Events CEID Name Description 12241 MH_TRAY_FULL_DETECTCLEAR Alarm clear: MH Tray Full Detect 12250 MH_TRAY_FULL_DETECT_ O-SET Alarm Set: MH Tray Full Detect O 12251 MH_TRAY_FULL_DETECT_ O-CLEAR Alarm clear: MH Tray Full Detect O 12260 MH_INVALID_SENSORSET Alarm Set: MH Invalid Sensor 12261 MH_INVALID_SENSORCLEAR Alarm clear: MH Invalid Sensor 12270 MH_TEACH_OPERATION_ WORKED-SET Alarm Set: MH Teach Operation Worked 12271 MH_TEACH_OPERATION_ WORKED-CLEAR Alarm clear: MH Teach Operation Worked 12280 WHL_UNDEFINED_CRR_L OCK_STS-SET Alarm Set: WHL Undefined CRR Lock STS 12281 WHL_UNDEFINED_CRR_L OCK_STS-CLEAR Alarm clear: WHL Undefined CRR Lock STS 12290 WHL_UNDEFINED_INDEX_ TYPE-SET Alarm Set: WHL Undefined Index Type 12291 WHL_UNDEFINED_INDEX_ TYPE-CLEAR Alarm clear: WHL Undefined Index Type 12300 WHL_UNDEFINED_INDEX_ STS-SET Alarm Set: WHL Undefined Index STS 12301 WHL_UNDEFINED_INDEX_ STS-CLEAR Alarm clear: WHL Undefined Index STS 12310 WHL_UNDEFINED_CORR_ STS-SET Alarm Set: WHL Undefined CORR STS 12311 WHL_UNDEFINED_CORR_ STS-CLEAR Alarm clear: WHL Undefined CORR STS 12320 WHL_UNDEFINED_INDEX_ CYCLE-SET Alarm Set: WHL Undefined Index Cycle 12321 WHL_UNDEFINED_INDEX_ CYCLE-CLEAR Alarm clear: WHL Undefined Index Cycle 12330 WHL_UNDEFINED_INDEXE R_STATE-SET Alarm Set: WHL Undefined Indexer State 12331 WHL_UNDEFINED_INDEXE R_STATE-CLEAR Alarm clear: WHL Undefined Indexer State 12340 WHL_UNDEFINED_PULLE R_STATE-SET Alarm Set: WHL Undefined Puller State (U2) Page - 217 - of 321 Sep 18, 2020 Rev 4.1 Kulicke & Soffa™ SECS/GEM Interface for K&S Ball Bonders Bonder software version x-xx-x-472-series IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Collection Events CEID Name Description 12341 WHL_UNDEFINED_PULLE R_STATE-CLEAR Alarm clear: WHL Undefined Puller State 12350 WHL_CANNOT_CREATE_S EMAPHORE-SET Alarm Set: WHL Cannot Create Semaphore 12351 WHL_CANNOT_CREATE_S EMAPHORE-CLEAR Alarm clear: WHL Cannot Create Semaphore 12360 WHL_CANNOT_OPEN_CH ANNEL-SET Alarm Set: WHL Cannot Open Channel 12361 WHL_CANNOT_OPEN_CH ANNEL-CLEAR Alarm clear: WHL Cannot Open Channel 12370 WHL_UNDEFINED_PULL_T YPE-SET Alarm Set: WHL Undefined Pull Type 12371 WHL_UNDEFINED_PULL_T YPE-CLEAR Alarm clear: WHL Undefined Pull Type 12380 WHL_WANTS_BONDHEAD _MOVED-SET Alarm Set: WHL Wants Bondhead Moved 12381 WHL_WANTS_BONDHEAD _MOVED-CLEAR Alarm clear: WHL Wants Bondhead Moved 12390 WHL_WANTS_BONDHEAD _POSITIONED-SET Alarm Set: WHL Wants Bondhead Positioned 12391 WHL_WANTS_BONDHEAD _POSITIONED-CLEAR Alarm clear: WHL Wants Bondhead Positioned 12400 MHS_CMD_TBL_SIZE_ERR OR-SET Alarm Set: MHS CMD TBL Size Error 12401 MHS_CMD_TBL_SIZE_ERR OR-CLEAR Alarm clear: MHS CMD TBL Size Error 12410 MHS_JDC_CMD_TIMEOUT -SET Alarm Set: MHS JDC CMD Time Out 12411 MHS_JDC_CMD_TIMEOUT -CLEAR Alarm clear: MHS JDC CMD Time Out 12420 PUSHER_KIT_JAM-SET Alarm Set: Pusher Kit Jam 12421 PUSHER_KIT_JAM-CLEAR Alarm clear: Pusher Kit Jam 12430 PUSHER_KIT_SENSOR_FA ILURE-SET Alarm Set: Pusher Kit Sensor Failure 12431 PUSHER_KIT_SENSOR_FA ILURE-CLEAR Alarm clear: Pusher Kit Sensor Failure 12440 SENSOR_MON_UNSAFESET Alarm Set: Sensor MON Unsafe 12441 SENSOR_MON_UNSAFECLEAR Alarm clear: Sensor MON Unsafe (U2) Page - 218 - of 321 Sep 18, 2020 Rev 4.1 Kulicke & Soffa™ SECS/GEM Interface for K&S Ball Bonders Bonder software version x-xx-x-472-series IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Collection Events CEID Name Description 12450 SENSOR_MON_UNSAFE_ WHEN_BONDING-SET Alarm Set: Sensor MON Unsafe When Bonding 12451 SENSOR_MON_UNSAFE_ WHEN_BONDING-CLEAR Alarm clear: Sensor MON Unsafe When Bonding 12460 MH_FAILED_GRIP_MAG_O -SET Alarm Set: MH Failed Grip Mag O 12461 MH_FAILED_GRIP_MAG_O -CLEAR Alarm clear: MH Failed Grip Mag O 12470 PULLER_GRIPPER_SENS OR_FAILURE-SET Alarm Set: Puller Gripper Sensor Failure 12471 PULLER_GRIPPER_SENS OR_FAILURE-CLEAR Alarm clear: Puller Gripper Sensor Failure 12480 RAILS_TARGET_POS_CLI PPED-SET Alarm Set: Rails Target POS Clipped 12481 RAILS_TARGET_POS_CLI PPED-CLEAR Alarm clear: Rails Target POS Clipped 12490 MHS_NEED_CAL_FOR_CI WIDTHCHK_NO_DONESET Alarm Set: MHS Need Cal For CIWIDTHCHK No Done 12491 MHS_NEED_CAL_FOR_CI WIDTHCHK_NO_DONECLEAR Alarm clear: MHS Need Cal For CIWIDTHCHK No Done 12500 EH_CAPILLARY_DETECTI ON_ERROR-SET Alarm Set: EH Capillary Detection Error 12501 EH_CAPILLARY_DETECTI ON_ERROR-CLEAR Alarm clear: EH Capillary Detection Error 12510 EH_FAST_PACKAGE_ALIG N_FAIL-SET Fast package alignment error set 12511 EH_FAST_PACKAGE_ALIG N_FAIL-CLEAR Fast package alignment error clear 12520 IND_LOAD_SENSOR_UNS AFE-SET Alarm Set: IND Load Sensor Unsafe 12521 IND_LOAD_SENSOR_UNS AFE-CLEAR Alarm clear: IND Load Sensor Unsafe 12530 RWH_INDEX_FAILURESET Alarm Set: RWH Index Failure 12531 RWH_INDEX_FAILURECLEAR Alarm clear: RWH Index Failure 12540 MHS_PARAMETER_ERRO R-SET Alarm Set: MHS Parameter Error (U2) Page - 219 - of 321 Sep 18, 2020 Rev 4.1 Kulicke & Soffa™ SECS/GEM Interface for K&S Ball Bonders Bonder software version x-xx-x-472-series IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Collection Events CEID Name Description 12541 MHS_PARAMETER_ERRO R-CLEAR Alarm clear: MHS Parameter Error 12550 RWH_IM_CMD_FAILURESET Alarm Set: RWH IM CMD Failure 12551 RWH_IM_CMD_FAILURECLEAR Alarm clear: RWH IM CMD Failure 12560 RWH_IV_CMD_FAILURESET Alarm Set: RWH IV CMD Failure 12561 RWH_IV_CMD_FAILURECLEAR Alarm clear: RWH IV CMD Failure 12570 RWH_CB_CMD_FAILURESET Alarm Set: RWH CB CMD Failure 12571 RWH_CB_CMD_FAILURECLEAR Alarm clear: RWH CB CMD Failure 12580 INDEX_GRP_SENSOR_FAI LURE-SET Alarm Set: Index GRP Sensor Failure 12581 INDEX_GRP_SENSOR_FAI LURE-CLEAR Alarm clear: Index GRP Sensor Failure 12590 EJECT_GRP_SENSOR_FAI LURE-SET Alarm Set: Eject GRP Sensor Failure 12591 EJECT_GRP_SENSOR_FAI LURE-CLEAR Alarm clear: Eject GRP Sensor Failure 12600 PUL_CARRIER_WRONG_O RIENTATION-SET Alarm Set: PUL Carrier Wrong Orientation 12601 PUL_CARRIER_WRONG_O RIENTATION-CLEAR Alarm clear: PUL Carrier Wrong Orientation 12610 PUL_CARRIER_ORIENTATI ON_EDGE_NOT_FOUNDSET Alarm Set: PUL Carrier Orientation Edge Not Found 12611 PUL_CARRIER_ORIENTATI ON_EDGE_NOT_FOUNDCLEAR Alarm clear: PUL Carrier Orientation Edge Not Found 12620 MHS_WHL_VERIFICATION _UNSUCCESSFUL-SET Alarm Set: MHS WHL Verification Unsucessful 12621 MHS_WHL_VERIFICATION _UNSUCCESSFUL-CLEAR Alarm clear: MHS WHL Verification Unsucessful 12630 INDEX_THETA_BAR_SENS OR_FAILURE-SET Alarm Set: Index Theta Bar Sensor Failure 12631 INDEX_THETA_BAR_SENS OR_FAILURE-CLEAR Alarm clear: Index Theta Bar Sensor Failure (U2) Page - 220 - of 321 Sep 18, 2020 Rev 4.1 Kulicke & Soffa™ SECS/GEM Interface for K&S Ball Bonders Bonder software version x-xx-x-472-series IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Collection Events CEID Name Description 12640 EJECT_THETA_BAR_SENS OR_FAILURE-SET Alarm Set: Eject Theta Bar Sensor Failure 12641 EJECT_THETA_BAR_SENS OR_FAILURE-CLEAR Alarm clear: Eject Theta Bar Sensor Failure 12650 MHS_GRIP_POINT_ERRO R-SET Alarm Set: MHS Grip Point Error 12651 MHS_GRIP_POINT_ERRO R-CLEAR Alarm clear: MHS Grip Point Error 12660 MHS_GP_ERROR_INDEX_ ABORT-SET Alarm Set: MHS GP Error Index Abort 12661 MHS_GP_ERROR_INDEX_ ABORT-CLEAR Alarm clear: MHS GP Error Index Abort 12670 LOAD_FAILED-SET Alarm Set: Load Failed 12671 LOAD_FAILED-CLEAR Alarm clear: Load Failed 12680 LOAD_INFO-SET Alarm Set: Load INFO 12681 LOAD_INFO-CLEAR Alarm clear: Load INFO 12690 LOAD_INTERNAL_ERRORSET Alarm Set: Load Internal Error 12691 LOAD_INTERNAL_ERRORCLEAR Alarm clear: Load Internal Error 12700 LOADER_BUSY-SET Alarm Set: Loader Busy 12701 LOADER_BUSY-CLEAR Alarm clear: Loader Busy 12710 AUTO_PARAM_LOAD_FAIL ED-SET Alarm Set: Auto Param Load Failed 12711 AUTO_PARAM_LOAD_FAIL ED-CLEAR Alarm clear: Auto Param Load Failed 12720 MISCT_PARAM_LOAD_FAI LED-SET Alarm Set: Misct Param Load Failed 12721 MISCT_PARAM_LOAD_FAI LED-CLEAR Alarm clear: Misct Param Load Failed 12730 LEADT_PARAM_LOAD_FAI LED-SET Alarm Set: Leadt Param Load Failed 12731 LEADT_PARAM_LOAD_FAI LED-CLEAR Alarm clear: Leadt Param Load Failed 12740 PADT_PARAM_LOAD_FAIL ED-SET Alarm Set: Padt Param Load Failed 12741 PADT_PARAM_LOAD_FAIL ED-CLEAR Alarm clear: Padt Param Load Failed (U2) Page - 221 - of 321 Sep 18, 2020 Rev 4.1 Kulicke & Soffa™ SECS/GEM Interface for K&S Ball Bonders Bonder software version x-xx-x-472-series IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Collection Events CEID Name Description 12750 INV_AUTO_PRM_DATA_PT R-SET Alarm Set: INV Auto PRM Data PTR 12751 INV_AUTO_PRM_DATA_PT R-CLEAR Alarm clear: INV Auto PRM Data PTR 12760 AUTO_PRM_RES_NOT_RE L-SET Alarm Set: Auto PRM RES Not REL 12761 AUTO_PRM_RES_NOT_RE L-CLEAR Alarm clear: Auto PRM RES Not REL 12770 AUTO_PRM_RES_NOT_AV L-SET Alarm Set: Auto PRM RES Not AVL 12771 AUTO_PRM_RES_NOT_AV L-CLEAR Alarm clear: Auto PRM RES Not AVL 12780 INV_TCH_PRM_DATA_PTR -SET Alarm Set: INV TCH PRM Data PTR 12781 INV_TCH_PRM_DATA_PTR -CLEAR Alarm clear: INV TCH PRM Data PTR 12790 MISCT_PRM_RES_NOT_R EL-SET Alarm Set: MISCT PRM RES Not REL 12791 MISCT_PRM_RES_NOT_R EL-CLEAR Alarm clear: MISCT PRM RES Not REL 12800 MISCT_PRM_RES_NOT_A VL-SET Alarm Set: MISCT PRM RES Not AVL 12801 MISCT_PRM_RES_NOT_A VL-CLEAR Alarm clear: MISCT PRM RES Not AVL 12810 LEADT_PRM_RES_NOT_R EL-SET Alarm Set: LeadT PRM RES Not REL 12811 LEADT_PRM_RES_NOT_R EL-CLEAR Alarm clear: LeadT PRM RES Not REL 12820 LEADT_PRM_RES_NOT_A VL-SET Alarm Set: LeadT PRM RES Not AVL 12821 LEADT_PRM_RES_NOT_A VL-CLEAR Alarm clear: LeadT PRM RES Not AVL 12830 PADT_PRM_RES_NOT_RE L-SET Alarm Set: PADT PRM RES Not REL 12831 PADT_PRM_RES_NOT_RE L-CLEAR Alarm clear: PADT PRM RES Not REL 12840 PADT_PRM_RES_NOT_AV L-SET Alarm Set: PADT PRM RES Not AVL 12841 PADT_PRM_RES_NOT_AV L-CLEAR Alarm clear: PADT PRM RES Not AVL (U2) Page - 222 - of 321 Sep 18, 2020 Rev 4.1 Kulicke & Soffa™ SECS/GEM Interface for K&S Ball Bonders Bonder software version x-xx-x-472-series IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Collection Events CEID Name Description 12850 RESTORE_ERROR-SET Alarm Set: Restore Error 12851 RESTORE_ERROR-CLEAR Alarm clear: Restore Error 12860 BACKUP_ERROR-SET Alarm Set: Backup Error 12861 BACKUP_ERROR-CLEAR Alarm clear: Backup Error 12870 SELECT_ERROR-SET Alarm Set: Select Error 12871 SELECT_ERROR-CLEAR Alarm clear: Select Error 12880 MEMORY_ERROR-SET Alarm Set: Memory Error 12881 MEMORY_ERROR-CLEAR Alarm clear: Memory Error 12890 FILE_ERROR-SET Alarm Set: File Error 12891 FILE_ERROR-CLEAR Alarm clear: File Error 12900 CLEANUP_ERROR-SET Alarm Set: Clean Up Error 12901 CLEANUP_ERROR-CLEAR Alarm clear: Clean Up Error 12910 BACKUP_LIST_FILE_INVAL ID-SET Alarm Set: Backup list File Invalid 12911 BACKUP_LIST_FILE_INVAL ID-CLEAR Alarm clear: Backup list File Invalid 12920 PP_HEAP_ALLOC_FAILEDSET Alarm Set: PP Heap Alloc Failed 12921 PP_HEAP_ALLOC_FAILEDCLEAR Alarm clear: PP Heap Alloc Failed 12930 PP_HEAP_CREATE_FAILE D-SET Alarm Set: PP Heap Create Failed 12931 PP_HEAP_CREATE_FAILE D-CLEAR Alarm clear: PP Heap Create Failed 12940 PP_HEAP_SIZE_INVALIDSET Alarm Set: PP Heap Size Invalid 12941 PP_HEAP_SIZE_INVALIDCLEAR Alarm clear: PP Heap Size Invalid 12950 MON-Y-MOTOR-OVERTEMP-SET Alarm Set: MON Motor Over Temp 12951 MON-Y-MOTOR-OVERTEMP-CLEAR Alarm clear: MON Motor Over Temp 12960 MON-MOTOR-WARNINGSET Alarm Set: MON Motor Warning 12961 MON-MOTOR-WARNINGCLEAR Alarm clear: MON Motor Warning 12970 MON-UPS-RUNNING-SET Alarm Set: MON UPS Running (U2) Page - 223 - of 321 Sep 18, 2020 Rev 4.1 Kulicke & Soffa™ SECS/GEM Interface for K&S Ball Bonders Bonder software version x-xx-x-472-series IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Collection Events CEID Name Description 12971 MON-UPS-RUNNINGCLEAR Alarm clear: MON UPS Running 12980 MON-SENSOR-BUSERROR-SET Alarm Set: MON Sensor Bus Error 12981 MON-SENSOR-BUSERROR-CLEAR Alarm clear: MON Sensor Bus Error 12990 MON-UPS-BAD-BATTERYSET Alarm Set: MON Ups Bad Battery 12991 MON-UPS-BAD-BATTERYCLEAR Alarm clear: MON Ups Bad Battery 13000 EH_MON_IDLE_CLAMP_O PEN_TIMEOUT-SET Alarm Set: EH MON Idle clamp Open Time Out 13001 EH_MON_IDLE_CLAMP_O PEN_TIMEOUT-CLEAR Alarm clear: EH MON Idle clamp Open Time Out 13010 EH_GRIPPER_SOLENOID_ OVER_TEMP_FAIL-SET Alarm Set: EH Gripper Solenoid Over Temp Fail 13011 EH_GRIPPER_SOLENOID_ OVER_TEMP_FAIL-CLEAR Alarm clear: EH Gripper Solenoid Over Temp Fail 13020 EH_STANDBY_SEND_MHS _COMMAND-SET Alarm Set: EH Standby Send MHS Command 13021 EH_STANDBY_SEND_MHS _COMMAND-CLEAR Alarm clear: EH Standby Send MHS Command 13030 EH_STANDBY_ERRORSET Alarm Set: EH Standby Error 13031 EH_STANDBY_ERRORCLEAR Alarm clear: EH Standby Error 13040 POWER-FAILURE-REBOOT-MACHINE-SET Alarm Set: Power Failure Reboot Machine 13041 POWER-FAILURE-REBOOT-MACHINE-CLEAR Alarm clear: Power Failure Reboot Machine 13050 MOMENTARY-POWERFAILURE-SET Alarm Set: Momentary Power Failure 13051 MOMENTARY-POWERFAILURE-CLEAR Alarm clear: Momentary Power Failure 13060 POWER-LOW--REBOOTMACHINE-SET Alarm Set: Power Low Reboot Machine 13061 POWER-LOW--REBOOTMACHINE-CLEAR Alarm clear: Power Low Reboot Machine 13070 MOMENTARY-POWERLOW-SET Alarm Set: Momentary Power Low (U2) Page - 224 - of 321 Sep 18, 2020 Rev 4.1 Kulicke & Soffa™ SECS/GEM Interface for K&S Ball Bonders Bonder software version x-xx-x-472-series IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Collection Events CEID Name Description 13071 MOMENTARY-POWERLOW-CLEAR Alarm clear: Momentary Power Low 13080 POWER-OVERTEMP-REBOOT-MACHINE-SET Alarm Set: Power Overtemp Reboot Machine 13081 POWER-OVERTEMP-REBOOT-MACHINE-CLEAR Alarm clear: Power Overtemp Reboot Machine 13090 MOMENTARY-POWEROVERTEMP-SET Alarm Set: Momentary Power Overtemp 13091 MOMENTARY-POWEROVERTEMP-CLEAR Alarm clear: Momentary Power Overtemp 13100 SYSTEM-FAILURE-REBOOT-MACHINE-SET Alarm Set: System Failure Reboot Machine 13101 SYSTEM-FAILURE-REBOOT-MACHINE-CLEAR Alarm clear: System Failure Reboot Machine 13110 MOMENTARY-SYSTEMFAILURE-SET Alarm Set: Momentary System Failure 13111 MOMENTARY-SYSTEMFAILURE-CLEAR Alarm clear: Momentary System Failure 13120 Z-CONTACT_FAILURE-SET Alarm Set: Z Contact Failure 13121 Z-CONTACT_FAILURECLEAR Alarm clear: Z Contact Failure 13130 Z-POSITION_ERROR-SET Alarm Set: Z Position Error 13131 Z-POSITION_ERRORCLEAR Alarm clear: Z Position Error 13140 ZSEEK_RECOVERY_ERRO R-SET Alarm Set: Z Seek Recovery Error 13141 ZSEEK_RECOVERY_ERRO R-CLEAR Alarm clear: Z Seek Recovery Error 13150 CPU2_Z_NEG_LIMIT_UPD ATE_ERROR-SET Alarm Set: CPU2 Z NEG Limit Update Error 13151 CPU2_Z_NEG_LIMIT_UPD ATE_ERROR-CLEAR Alarm clear: CPU2 Z NEG Limit Update Error 13160 X-POSITION_ERROR-SET Alarm Set: X Position Error 13161 X-POSITION_ERRORCLEAR Alarm clear: X Position Error 13170 Y-POSITION_ERROR-SET Alarm Set: Y Position Error 13171 Y-POSITION_ERRORCLEAR Alarm clear: Y Position Error (U2) Page - 225 - of 321 Sep 18, 2020 Rev 4.1 Kulicke & Soffa™ SECS/GEM Interface for K&S Ball Bonders Bonder software version x-xx-x-472-series IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Collection Events CEID Name Description 13180 EH_Z_LIMIT_FIND_ERROR -SET Alarm Set: EH Z Limit Find Error 13181 EH_Z_LIMIT_FIND_ERROR -CLEAR Alarm clear: EH Z Limit Find Error 13190 EH_BFC_MOTION_ERROR -SET Alarm Set: EH BFC Motion Error 13191 EH_BFC_MOTION_ERROR -CLEAR Alarm clear: EH BFC Motion Error 13200 EH_BFC_NON_MOTION_E RROR-SET Alarm Set: EH BFC NON Motion Error 13201 EH_BFC_NON_MOTION_E RROR-CLEAR Alarm clear: EH BFC NON Motion Error 13210 EH_ZMAP_MOTION_ERRO R-SET Alarm Set: EH ZMAP Motion Error 13211 EH_ZMAP_MOTION_ERRO R-CLEAR Alarm clear: EH ZMAP Motion Error 13220 EH_BITS_AGC_CAL_NOT_ DONE-SET Alarm Set: EH BITS AGC CAL Not Done 13221 EH_BITS_AGC_CAL_NOT_ DONE-CLEAR Alarm clear: EH BITS AGC CAL Not Done 13230 EH_FS_BONDOFF_VERIFY _FAIL-SET Alarm Set: EH FS Bondoff Verify Fail 13231 EH_FS_BONDOFF_VERIFY _FAIL-CLEAR Alarm clear: EH FS Bondoff Verify Fail 13240 EH_WFEED_COMPORT_O PER_ERROR-SET Alarm Set: EH Wfeed COMPORT Oper Error 13241 EH_WFEED_COMPORT_O PER_ERROR-CLEAR Alarm clear: EH Wfeed COMPORT Oper Error 13250 EH_WFEED_COMMUNICA TION_ERROR-SET Alarm Set: EH Wfeed Communication Error 13251 EH_WFEED_COMMUNICA TION_ERROR-CLEAR Alarm clear: EH Wfeed Communication Error 13260 TEMPERATURE_COMMUN ICATION_ERROR-SET Alarm Set: Temperature Communication Error 13261 TEMPERATURE_COMMUN ICATION_ERROR-CLEAR Alarm clear: Temperature Communication Error 13270 EH_TEMP_INVALID_PARA MS-SET Alarm Set: EH Temp Invalid Params 13271 EH_TEMP_INVALID_PARA MS-CLEAR Alarm clear: EH Temp Invalid Params (U2) Page - 226 - of 321 Sep 18, 2020 Rev 4.1 Kulicke & Soffa™ SECS/GEM Interface for K&S Ball Bonders Bonder software version x-xx-x-472-series IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Collection Events CEID Name Description 13280 EH_TEMP_RESOURCE_AC QUIRE_ERROR-SET Alarm Set: EH Temp Resource Acquire Error 13281 EH_TEMP_RESOURCE_AC QUIRE_ERROR-CLEAR Alarm clear: EH Temp Resource Acquire Error 13290 EH_TEMP_INVALID_SYS_ R_SELECTOR-SET Alarm Set: EH Temp Invalid SYS R Selector 13291 EH_TEMP_INVALID_SYS_ R_SELECTOR-CLEAR Alarm clear: EH Temp Invalid SYS R Selector 13300 EH_TEMP_INVALID_SYS_ G_SELECTOR-SET Alarm Set: EH Temp Invalid SYS G Selector 13301 EH_TEMP_INVALID_SYS_ G_SELECTOR-CLEAR Alarm clear: EH Temp Invalid SYS G Selector 13310 EH_TEMP_INVALID_ZONE _R_SELECTOR-SET Alarm Set: EH Temp Invalid Zone R Selector 13311 EH_TEMP_INVALID_ZONE _R_SELECTOR-CLEAR Alarm clear: EH Temp Invalid Zone R Selector 13320 EH_TEMP_INVALID_ZONE _EM_SELECTOR-SET Alarm Set: EH Temp Invalid Zone EM Selector 13321 EH_TEMP_INVALID_ZONE _EM_SELECTOR-CLEAR Alarm clear: EH Temp Invalid Zone EM Selector 13330 EH_TEMP_PID_RESET_VA LUE_ERROR-SET Alarm Set: EH Temp Pid Reset Value Error 13331 EH_TEMP_PID_RESET_VA LUE_ERROR-CLEAR Alarm clear: EH Temp Pid Reset Value Error 13340 EH_TEMP_OFFSET_VALU E_ERROR-SET Alarm Set: EH Temp Offset Value Error 13341 EH_TEMP_OFFSET_VALU E_ERROR-CLEAR Alarm clear: EH Temp Offset Value Error 13350 EH_TEMP_ZONE_EM_PAR AM_ERROR-SET Alarm Set: EH Temp Zone EM Param Error 13351 EH_TEMP_ZONE_EM_PAR AM_ERROR-CLEAR Alarm clear: EH Temp Zone EM Param Error 13360 EH_TEMP_SERIAL_WRITE _ERROR-SET Alarm Set: EH Temp Serial Write Error 13361 EH_TEMP_SERIAL_WRITE _ERROR-CLEAR Alarm clear: EH Temp Serial Write Error 13370 EH_TEMP_SERIAL_READ_ ERROR-SET Alarm Set: EH Temp Serial Read Error 13371 EH_TEMP_SERIAL_READ_ ERROR-CLEAR Alarm clear: EH Temp Serial Read Error (U2) Page - 227 - of 321 Sep 18, 2020 Rev 4.1 Kulicke & Soffa™ SECS/GEM Interface for K&S Ball Bonders Bonder software version x-xx-x-472-series IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Collection Events CEID Name Description 13380 EH_TEMP_ERROR_MSG_ REPLY-SET Alarm Set: EH Temp Error MSG Reply 13381 EH_TEMP_ERROR_MSG_ REPLY-CLEAR Alarm clear: EH Temp Error MSG Reply 13390 EH_TEMP_READ_NOT_RE ADY-SET Alarm Set: EH Temp Read Not Ready 13391 EH_TEMP_READ_NOT_RE ADY-CLEAR Alarm clear: EH Temp Read Not Ready 13400 EH_TEMP_WRITE_NOT_R EADY-SET Alarm Set: EH Temp Write Not Ready 13401 EH_TEMP_WRITE_NOT_R EADY-CLEAR Alarm clear: EH Temp Write Not Ready 13410 EH_TEMP_IO_SELECT_ER ROR-SET Alarm Set: EH Temp IO Select Error 13411 EH_TEMP_IO_SELECT_ER ROR-CLEAR Alarm clear: EH Temp IO Select Error 13420 EH_TEMP_WRITE_PROTE CTED_PARM-SET Alarm Set: EH Temp Write Protected Parm 13421 EH_TEMP_WRITE_PROTE CTED_PARM-CLEAR Alarm clear: EH Temp Write Protected Parm 13430 EH_TEMP_UNKNOWN_ER ROR-SET Alarm Set: EH Temp Unknown Error 13431 EH_TEMP_UNKNOWN_ER ROR-CLEAR Alarm clear: EH Temp Unknown Error 13440 EH_TEMP_CHANGERATE_ ERROR-SET Alarm Set: EH Temp Changerate Error 13441 EH_TEMP_CHANGERATE_ ERROR-CLEAR Alarm clear: EH Temp Changerate Error 13450 EH_IDIAG_SYNCH_ERROR -SET Alarm Set: EH Idiag SYNCH Error 13451 EH_IDIAG_SYNCH_ERROR -CLEAR Alarm clear: EH Idiag SYNCH Error 13460 EH_IDIAG_ASYNCH_ERRO R-SET Alarm Set: EH Idiag ASYNCH Error 13461 EH_IDIAG_ASYNCH_ERRO R-CLEAR Alarm clear: EH Idiag ASYNCH Error 13470 EH_IDIAG_TEMP_ZONE_F AULT-SET Alarm Set: EH Idiag Temp Zone Fault 13471 EH_IDIAG_TEMP_ZONE_F AULT-CLEAR Alarm clear: EH Idiag Temp Zone Fault (U2) Page - 228 - of 321 Sep 18, 2020 Rev 4.1 Kulicke & Soffa™ SECS/GEM Interface for K&S Ball Bonders Bonder software version x-xx-x-472-series IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Collection Events CEID Name Description 13480 EH_IDIAG_BITS_MODE_H W_SW_MISMATCH-SET Alarm Set: EH Idiag BITS Mode HW SW MISMATCH 13481 EH_IDIAG_BITS_MODE_H W_SW_MISMATCH-CLEAR Alarm clear: EH Idiag BITS Mode HW SW MISMATCH 13490 EH_IDIAG_BITS_CROSSLO AD_ERROR-SET Alarm Set: EH Idiag BITS Crossload Error 13491 EH_IDIAG_BITS_CROSSLO AD_ERROR-CLEAR Alarm clear: EH Idiag BITS Crossload Error 13500 EH_BITS_FULL_AGC_FAIL ED-SET Alarm Set: EH BITS FULL AGC Failed 13501 EH_BITS_FULL_AGC_FAIL ED-CLEAR Alarm clear: EH BITS FULL AGC Failed 13510 EH_BITS_WF_DUMP_FAIL ED-SET Alarm Set: EH BITS WF Dump Failed 13511 EH_BITS_WF_DUMP_FAIL ED-CLEAR Alarm clear: EH BITS WF Dump Failed 13520 EH_BITS_WF_LOG_FAILE D-SET Alarm Set: EH BITS WF LOG Failed 13521 EH_BITS_WF_LOG_FAILE D-CLEAR Alarm clear: EH BITS WF LOG Failed 13530 EH_IDIAG_EEPROM_ERR OR-SET Alarm Set: EH BITS EEPROM Error 13531 EH_IDIAG_EEPROM_ERR OR-CLEAR Alarm clear: EH BITS EEPROM Error 13540 EH_IDIAG_INVALID_TABLE _CONFIG-SET Alarm Set: EH Idiag Invalid Table Configure 13541 EH_IDIAG_INVALID_TABLE _CONFIG-CLEAR Alarm clear: EH Idiag Invalid Table Configure 13550 TAR_ERROR-SET Alarm Set: Tar Error 13551 TAR_ERROR-CLEAR Alarm clear: Tar Error 13560 TAR_WARNING-SET Alarm Set: Tar Warning 13561 TAR_WARNING-CLEAR Alarm clear: Tar Warning 13570 FLOPPY_WRITE_PROTEC TED-SET Alarm Set: Floppy Write Protected 13571 FLOPPY_WRITE_PROTEC TED-CLEAR Alarm clear: Floppy Write Protected 13580 FLOPPY_INSERT_ERRORSET Alarm Set: Floppy Insert Error 13581 FLOPPY_INSERT_ERRORCLEAR Alarm clear: Floppy Insert Error (U2) Page - 229 - of 321 Sep 18, 2020 Rev 4.1 Kulicke & Soffa™ SECS/GEM Interface for K&S Ball Bonders Bonder software version x-xx-x-472-series IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Collection Events CEID Name Description 13590 DEVICE_READY_ERRORSET Alarm Set: Device Ready Error 13591 DEVICE_READY_ERRORCLEAR Alarm clear: Device Ready Error 13600 DISK_FULL_ERROR-SET Alarm Set: Disk Full Error 13601 DISK_FULL_ERRORCLEAR Alarm clear: Disk Full Error 13610 INSERT_NEXT_DISK-SET Alarm Set: Insert Next Disk 13611 INSERT_NEXT_DISKCLEAR Alarm clear: Insert Next Disk 13620 CALIBRATION_DATA_ERR OR-SET Alarm Set: Calibration Data Error 13621 CALIBRATION_DATA_ERR OR-CLEAR Alarm clear: Calibration Data Error 13630 INVALID-SET Alarm Set: Invalid 13631 INVALID-CLEAR Alarm clear:Invalid 13640 MISSING_MARKERS-SET Alarm Set: Missing Markers 13641 MISSING_MARKERSCLEAR Alarm clear: Missing Markers 13650 CRC_OR_TIME_INVALIDSET Alarm Set: CRC Or Time Invalid 13651 CRC_OR_TIME_INVALIDCLEAR Alarm clear: CRC Or Time Invalid 13660 CRC_STRING_LENGTH_IN VALID-SET Alarm Set: CRC String Length Invalid 13661 CRC_STRING_LENGTH_IN VALID-CLEAR Alarm clear: CRC String Length Invalid 13670 TIME_STRING_LENGTH_IN VALID-SET Alarm Set: Time String Length Invalid 13671 TIME_STRING_LENGTH_IN VALID-CLEAR Alarm clear: Time String Length Invalid 13680 EH_BONDER_CONFIG_ER ROR-SET Alarm Set: EH Bonder Configure Error 13681 EH_BONDER_CONFIG_ER ROR-CLEAR Alarm clear: EH Bonder Configure Error 13690 EH_FAINT6_CPU_SPURIO US_INT-SET Alarm Set: EH Faint6 CPU Spurious INT 13691 EH_FAINT6_CPU_SPURIO US_INT-CLEAR Alarm clear: EH Faint6 CPU Spurious INT (U2) Page - 230 - of 321 Sep 18, 2020 Rev 4.1 Kulicke & Soffa™ SECS/GEM Interface for K&S Ball Bonders Bonder software version x-xx-x-472-series IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Collection Events CEID Name Description 13700 EH_PCI_BRIDGE_FAILURE -SET Alarm Set: EH PCI Bridge Failure 13701 EH_PCI_BRIDGE_FAILURE -CLEAR Alarm clear: EH PCI Bridge Failure 13710 EH_SERDES_BUS_ERROR -SET Alarm Set: EH Serdes Bus Error 13711 EH_SERDES_BUS_ERROR -CLEAR Alarm clear: EH Serdes Bus Error 13720 EH_CHESS_IN_USE-SET Alarm Set: EH Chess In Use 13721 EH_CHESS_IN_USECLEAR Alarm clear: EH Chess In Use 13730 EH_ILLEGAL_CHESS_REL EASE-SET Alarm Set: EH Illegal Chess Release 13731 EH_ILLEGAL_CHESS_REL EASE-CLEAR Alarm clear: EH Illegal Chess Release 13740 EH_ILLEGAL_CHESS_NAM E-SET Alarm Set: EH Illegal Chess Name 13741 EH_ILLEGAL_CHESS_NAM E-CLEAR Alarm clear: EH Illegal Chess Name 13750 NVR_MAC_ADDR_CORRU PTION-SET Alarm Set: NVR MAC ADDR Corruption 13751 NVR_MAC_ADDR_CORRU PTION-CLEAR Alarm clear: NVR MAC ADDR Corruption 13760 NVR_PROT_MEM_CORRU PTION-SET Alarm Set: NVR PROT MEM Corruption 13761 NVR_PROT_MEM_CORRU PTION-CLEAR Alarm clear: NVR PROT MEM Corruption 13770 NVR_GENERAL_MEM_CO RRUPTION-SET Alarm Set: NVR General MEM Corruption 13771 NVR_GENERAL_MEM_CO RRUPTION-CLEAR Alarm clear: NVR General MEM Corruption 13780 EH-BOOT-PARM-SAVEERR-SET Alarm Set: EH Boot Parm Save Error 13781 EH-BOOT-PARM-SAVEERR-CLEAR Alarm clear: EH Boot Parm Save Error 13790 EH-BOOT-PARM-SET-ERRSET Alarm Set: EH Boot Parm Set Error 13791 EH-BOOT-PARM-SET-ERRCLEAR Alarm clear: EH Boot Parm Set Error (U2) Page - 231 - of 321 Sep 18, 2020 Rev 4.1 Kulicke & Soffa™ SECS/GEM Interface for K&S Ball Bonders Bonder software version x-xx-x-472-series IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Collection Events CEID Name Description 13800 EH-BOOT-PARMRESTORE-ERR-SET Alarm Set: EH Boot Parm Restore Error 13801 EH-BOOT-PARMRESTORE-ERR-CLEAR Alarm clear: EH Boot Parm Restore Error 13810 EH-INSTALL-KERNELCOPY-ERR-SET Alarm Set: EH Install Kernel Copy Error 13811 EH-INSTALL-KERNELCOPY-ERR-CLEAR Alarm clear: EH Install Kernel Copy Error 13820 EH-INSTALL-PROCESSERR-SET Alarm Set: EH Install Process Error 13821 EH-INSTALL-PROCESSERR-CLEAR Alarm clear: EH Install Process Error 13830 VDKError_kUnknownThread Type-SET Alarm Set: VDKError kUnknownThreadType 13831 VDKError_kUnknownThread Type-CLEAR Alarm clear: VDKError kUnknownThreadType 13840 VDKError_kUnknownThread -SET Alarm Set: VDKError kUnknownThread 13841 VDKError_kUnknownThread -CLEAR Alarm clear: VDKError kUnknownThread 13850 VDKError_kThreadCreationF ailure-SET Alarm Set: VDKError kThreadCreationFailure 13851 VDKError_kThreadCreationF ailure-CLEAR Alarm clear: VDKError kThreadCreationFailure 13860 VDKError_kUnknownSemap hore-SET Alarm Set: VDKError kUnknownSemaphore 13861 VDKError_kUnknownSemap hore-CLEAR Alarm clear: VDKError kUnknownSemaphore 13870 VDKError_kUnknownEventB it-SET Alarm Set: VDKError kUnknownEventBit 13871 VDKError_kUnknownEventB it-CLEAR Alarm clear: VDKError kUnknownEventBit 13880 VDKError_kUnknownEventSET Alarm Set: VDKError kUnknownEvent 13881 VDKError_kUnknownEventCLEAR Alarm clear: VDKError kUnknownEvent 13890 VDKError_kInvalidPrioritySET Alarm Set: VDKError kInvalidPriority 13891 VDKError_kInvalidPriorityCLEAR Alarm clear: VDKError kInvalidPriority (U2) Page - 232 - of 321 Sep 18, 2020 Rev 4.1 Kulicke & Soffa™ SECS/GEM Interface for K&S Ball Bonders Bonder software version x-xx-x-472-series IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Collection Events CEID Name Description 13900 VDKError_kInvalidDelaySET Alarm Set: VDKError kInvalidDelay 13901 VDKError_kInvalidDelayCLEAR Alarm clear: VDKError kInvalidDelay 13910 VDKError_kSemaphoreTime out-SET Alarm Set: VDKError kSemaphore Time Out 13911 VDKError_kSemaphoreTime out-CLEAR Alarm clear: VDKError kSemaphore Time Out 13920 VDKError_kEventTimeoutSET Alarm Set: VDKError kEvent Time Out 13921 VDKError_kEventTimeoutCLEAR Alarm clear: VDKError kEvent Time Out 13930 VDKError_kBlockInInvalidRe gion-SET Alarm Set: VDKError kBlockInInvalidRegion 13931 VDKError_kBlockInInvalidRe gion-CLEAR Alarm clear: VDKError kBlockInInvalidRegion 13940 VDKError_kDbgPossibleBloc kInRegion-SET Alarm Set: VDKError kDbgPossibleBlockInRegion 13941 VDKError_kDbgPossibleBloc kInRegion-CLEAR Alarm clear: VDKError kDbgPossibleBlockInRegion 13950 VDKError_kInvalidPeriodSET Alarm Set: VDKError kInvaldPeriod 13951 VDKError_kInvalidPeriodCLEAR Alarm clear: VDKError kInvaldPeriod 13960 VDKError_kAlreadyPeriodicSET Alarm Set: VDKError kAlreadyPeriodic 13961 VDKError_kAlreadyPeriodicCLEAR Alarm clear: VDKError kAlreadyPeriodic 13970 VDKError_kNonperiodicSem aphore-SET Alarm Set: VDkError kNonperiodicSemaphore 13971 VDKError_kNonperiodicSem aphore-CLEAR Alarm clear: VDkError kNonperiodicSemaphore 13980 VDKError_kDbgPopUnderflo w-SET Alarm Set: VDKError kDbgPopUnderFlow 13981 VDKError_kDbgPopUnderflo w-CLEAR Alarm clear: VDKError kDbgPopUnderFlow 13990 VDKError_kBadIOID-SET Alarm Set: VDKError kBadIOID 13991 VDKError_kBadIOID-CLEAR Alarm clear: VDKError kBadIOID 14000 VDKError_kBadDeviceDescr iptor-SET Alarm Set: VDKError kBadDeviceDescriptor (U2) Page - 233 - of 321 Sep 18, 2020 Rev 4.1 Kulicke & Soffa™ SECS/GEM Interface for K&S Ball Bonders Bonder software version x-xx-x-472-series IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Collection Events CEID Name Description 14001 VDKError_kBadDeviceDescr iptor-CLEAR Alarm clear: VDKError kBadDeviceDescriptor 14010 VDKError_kOpenFailureSET Alarm Set: VDKError kOpenFailure 14011 VDKError_kOpenFailureCLEAR Alarm clear: VDKError kOpenFailure 14020 VDKError_kCloseFailureSET Alarm Set: VDKError kCloseFailure 14021 VDKError_kCloseFailureCLEAR Alarm clear: VDKError kCloseFailure 14030 VDKError_kReadFailureSET Alarm Set: VDKError kReadFailure 14031 VDKError_kReadFailureCLEAR Alarm clear: VDKError kReadFailure 14040 VDKError_kWriteFailureSET Alarm Set: VDKError kWriteFailure 14041 VDKError_kWriteFailureCLEAR Alarm clear: VDKError kWriteFailure 14050 VDKError_kIOCtlFailureSET Alarm Set: VDKError kIOCtlFailure 14051 VDKError_kIOCtlFailureCLEAR Alarm clear: VDKError kIOCtlFailure 14060 VDKError_kInvalidDeviceFla g-SET Alarm Set: VDKError kInvalidDeviceFlag 14061 VDKError_kInvalidDeviceFla g-CLEAR Alarm clear: VDKError kInvalidDeviceFlag 14070 VDKError_kDeviceTimeoutSET Alarm Set: VDKError kDeviceTimeOut 14071 VDKError_kDeviceTimeoutCLEAR Alarm clear: VDKError kDeviceTimeOut 14080 VDKError_kDeviceFlagCreat ionFailure-SET Alarm Set: VDKError kDeviceFlagCreationFailure 14081 VDKError_kDeviceFlagCreat ionFailure-CLEAR Alarm clear: VDKError kDeviceFlagCreationFailure 14090 VDKError_kMaxCountExcee ded-SET Alarm Set: VDKError kMaxCountExceeded 14091 VDKError_kMaxCountExcee ded-CLEAR Alarm clear: VDKError kMaxCountExceeded 14100 VDKError_kSemaphoreCrea tionFailure-SET Alarm Set: VDKError kSemaphoreCreationFailure (U2) Page - 234 - of 321 Sep 18, 2020 Rev 4.1 Kulicke & Soffa™ SECS/GEM Interface for K&S Ball Bonders Bonder software version x-xx-x-472-series IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Collection Events CEID Name Description 14101 VDKError_kSemaphoreCrea tionFailure-CLEAR Alarm clear: VDKError kSemaphoreCreationFailure 14110 VDKError_kSemaphoreDestr uctionFailure-SET Alarm Set: VDKError kSemaphoreDestructionFailure 14111 VDKError_kSemaphoreDestr uctionFailure-CLEAR Alarm clear: VDKError kSemaphoreDestructionFailure 14120 VDKError_kPoolCreationFail ure-SET Alarm Set: VDKError kPoolCreationFailure 14121 VDKError_kPoolCreationFail ure-CLEAR Alarm clear: VDKError kPoolCreationFailure 14130 VDKError_kInvalidBlockPoin ter-SET Alarm Set: VDKError kInvalidBlockPointer 14131 VDKError_kInvalidBlockPoin ter-CLEAR Alarm clear: VDKError kInvalidBlockPointer 14140 VDKError_kInvalidPoolParm s-SET Alarm Set: VDKError kInvalidPoolParms 14141 VDKError_kInvalidPoolParm s-CLEAR Alarm clear: VDKError kInvalidPoolParms 14150 VDKError_kInvalidPoolIDSET Alarm Set: VDKError kInvalidPoolID 14151 VDKError_kInvalidPoolIDCLEAR Alarm clear: VDKError kInvalidPoolID 14160 VDKError_kErrorPoolNotEm pty-SET Alarm Set: VDKError kErrorPoolNotEmpty 14161 VDKError_kErrorPoolNotEm pty-CLEAR Alarm clear: VDKError kErrorPoolNotEmpty 14170 VDKError_kErrorMallocBlock -SET Alarm Set: VDKError kErrorMallocBlock 14171 VDKError_kErrorMallocBlock -CLEAR Alarm clear: VDKError kErrorMallocBlock 14180 VDKError_kMessageCreatio nFailure-SET Alarm Set: VDKError kMessageCreationFailure 14181 VDKError_kMessageCreatio nFailure-CLEAR Alarm clear: VDKError kMessageCreationFailure 14190 VDKError_kInvalidMessageI D-SET Alarm Set: VDKError kInvalidMessageID 14191 VDKError_kInvalidMessageI D-CLEAR Alarm clear: VDKError kInvalidMessageID 14200 VDKError_kInvalidMessage Owner-SET Alarm Set: VDKError kInvalidMessageOwner (U2) Page - 235 - of 321 Sep 18, 2020 Rev 4.1 Kulicke & Soffa™ SECS/GEM Interface for K&S Ball Bonders Bonder software version x-xx-x-472-series IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Collection Events CEID Name Description 14201 VDKError_kInvalidMessage Owner-CLEAR Alarm clear: VDKError kInvalidMessageOwner 14210 VDKError_kInvalidMessage Channel-SET Alarm Set: VDKError kInvalidMessageChannel 14211 VDKError_kInvalidMessage Channel-CLEAR Alarm clear: VDKError kInvalidMessageChannel 14220 VDKError_kMessageTimeou t-SET Alarm Set: VDKError kMessageTimeOut 14221 VDKError_kMessageTimeou t-CLEAR Alarm clear: VDKError kMessageTimeOut 14230 VDKError_kMessageInQueu e-SET Alarm Set: VDKError kMessageInQueue 14231 VDKError_kMessageInQueu e-CLEAR Alarm clear: VDKError kMessageInQueue 14240 TCPError_ENOBUFS-SET Alarm Set: TCPError ENOBUFS 14241 TCPError_ENOBUFSCLEAR Alarm clear: TCPError ENOBUFS 14250 TCPError_ETIMEDOUTSET Alarm Set: TCPError ETIMEDOUT 14251 TCPError_ETIMEDOUTCLEAR Alarm clear: TCPError ETIMEDOUT 14260 TCPError_EISCONN-SET Alarm Set: TCPError EISCONN 14261 TCPError_EISCONNCLEAR Alarm clear: TCPError EISCONN 14270 TCPError_EOPNOTSUPPSET Alarm Set: TCPError EOPNOTSUPP 14271 TCPError_EOPNOTSUPPCLEAR Alarm clear: TCPError EOPNOTSUPP 14280 TCPError_ECONNABORTE D-SET Alarm Set: TCPError ECONNABORTED 14281 TCPError_ECONNABORTE D-CLEAR Alarm clear: TCPError ECONNABORTED 14290 TCPError_EWOULDBLOCKSET Alarm Set: TCPError EWOULDBLOCK 14291 TCPError_EWOULDBLOCKCLEAR Alarm clear: TCPError EWOULDBLOCK 14300 TCPError_ECONNREFUSE D-SET Alarm Set: TCPError ECONNREFUSED 14301 TCPError_ECONNREFUSE D-CLEAR Alarm clear: TCPError ECONNREFUSED (U2) Page - 236 - of 321 Sep 18, 2020 Rev 4.1 Kulicke & Soffa™ SECS/GEM Interface for K&S Ball Bonders Bonder software version x-xx-x-472-series IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Collection Events CEID Name Description 14310 TCPError_ECONNRESETSET Alarm Set: TCPError ECONNRESET 14311 TCPError_ECONNRESETCLEAR Alarm clear: TCPError ECONNRESET 14320 TCPError_ENOTCONN-SET Alarm Set: TCPError ENOTCONN 14321 TCPError_ENOTCONNCLEAR Alarm clear: TCPError ENOTCONN 14330 TCPError_EALREADY-SET Alarm Set: TCPError EALREADY 14331 TCPError_EALREADYCLEAR Alarm clear: TCPError EALREADY 14340 TCPError_EINVAL-SET Alarm Set: TCPError EINVAL 14341 TCPError_EINVAL-CLEAR Alarm clear: TCPError EINVAL 14350 TCPError_EMSGSIZE-SET Alarm Set: TCPError EMSGSIZE 14351 TCPError_EMSGSIZECLEAR Alarm clear: TCPError EMSGSIZE 14360 TCPError_EPIPE-SET Alarm Set: TCPError EPIPE 14361 TCPError_EPIPE-CLEAR Alarm clear: TCPError EPIPE 14370 TCPError_EDESTADDRRE Q-SET Alarm Set: TCPError EDESTADDRREQ 14371 TCPError_EDESTADDRRE Q-CLEAR Alarm clear: TCPError EDESTADDRREQ 14380 TCPError_ESHUTDOWNSET Alarm Set: TCPError ESHUTDOWN 14381 TCPError_ESHUTDOWNCLEAR Alarm clear: TCPError ESHUTDOWN 14390 TCPError_ENOPROTOOPTSET Alarm Set: TCPError ENOPROTOOPT 14391 TCPError_ENOPROTOOPTCLEAR Alarm clear: TCPError ENOPROTOOPT 14400 TCPError_EHAVEOOB-SET Alarm Set: TCPError EHAVEOOB 14401 TCPError_EHAVEOOBCLEAR Alarm clear: TCPError EHAVEOOB 14410 TCPError_ENOMEM-SET Alarm Set: TCPError ENOMEM 14411 TCPError_ENOMEMCLEAR Alarm clear: TCPError ENOMEM 14420 TCPError_EADDRNOTAVAI L-SET Alarm Set: TCPError EADDRNOTAVAIL (U2) Page - 237 - of 321 Sep 18, 2020 Rev 4.1 Kulicke & Soffa™ SECS/GEM Interface for K&S Ball Bonders Bonder software version x-xx-x-472-series IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Collection Events CEID Name Description 14421 TCPError_EADDRNOTAVAI L-CLEAR Alarm clear: TCPError EADDRNOTAVAIL 14430 TCPError_EADDRINUSESET Alarm Set: TCPError EADDRINUSE 14431 TCPError_EADDRINUSECLEAR Alarm clear: TCPError EADDRINUSE 14440 TCPError_EAFNOSUPPOR T-SET Alarm Set: TCPError EAFNOSUPPORT 14441 TCPError_EAFNOSUPPOR T-CLEAR Alarm clear: TCPError EAFNOSUPPORT 14450 TCPError_EINPROGRESSSET Alarm Set: TCPError EINPROGRESS 14451 TCPError_EINPROGRESSCLEAR Alarm clear: TCPError EINPROGRESS 14460 TCPError_ELOWER-SET Alarm Set: TCPError ELOWER 14461 TCPError_ELOWER-CLEAR Alarm clear: TCPError ELOWER 14470 TCPError_KN_EBADF-SET Alarm Set: TCPError KN EBADF 14471 TCPError_KN_EBADFCLEAR Alarm clear: TCPError KN EBADF 14480 TCPError_EIEIO-SET Alarm Set: TCPError EIEIO 14481 TCPError_EIEIO-CLEAR Alarm clear: TCPError EIEIO 14490 PBI_BALL_RETEACH_REQ UIRED-SET Alarm Set: PBI BALL RETEACH REQUIRED 14491 PBI_BALL_RETEACH_REQ UIRED-CLEAR Alarm clear: PBI BALL RETEACH REQUIRED 14500 EH_EJECT_MAG_FLASHSET Alarm Set: EH Eject MAG Flash 14501 EH_EJECT_MAG_FLASHCLEAR Alarm clear: EH Eject MAG Flash 14510 O_MAG_EJECT_THRESHO LD_WARNING_HEADERSET Alarm Set: Output MAG Eject Threshold Warning Header 14511 O_MAG_EJECT_THRESHO LD_WARNING_HEADERCLEAR Alarm clear: Output MAG Eject Threshold Warning Header 14520 INV_POWERSAVE_PRM_D ATA_PTR-SET Alarm Set: INV Powersave PRM Data PTR 14521 INV_POWERSAVE_PRM_D ATA_PTR-CLEAR Alarm clear: INV Powersave PRM Data PTR (U2) Page - 238 - of 321 Sep 18, 2020 Rev 4.1 Kulicke & Soffa™ SECS/GEM Interface for K&S Ball Bonders Bonder software version x-xx-x-472-series IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Collection Events CEID Name Description 14530 PAD-FOR-PBI-NOTFOUND-SET Alarm Set: PAD For PBI Not Found 14531 PAD-FOR-PBI-NOTFOUND-CLEAR Alarm clear: PAD For PBI Not Found 14540 BALL-EXPECT-OUT-OFPAD-SET Alarm Set: Ball Expect Out Of Pad 14541 BALL-EXPECT-OUT-OFPAD-CLEAR Alarm clear: Ball Expect Out Of Pad 14550 EH_AUTO_CONSECUTIVE _FALSE_PRS_NSOP-SET Alarm Set: EH Auto Consecutive False PRS NSOP 14551 EH_AUTO_CONSECUTIVE _FALSE_PRS_NSOPCLEAR Alarm clear: EH Auto Consecutive False PRS NSOP 14560 AUTO_XHAIR_MAP_INACT IVE-SET Alarm Set: Auto Xhair Map Inactive 14561 AUTO_XHAIR_MAP_INACT IVE-CLEAR Alarm clear: Auto Xhair Map Inactive 14570 BHLIFTER_AIR_AUTO-SET Alarm Set: BHLIFTER AIR Auto 14571 BHLIFTER_AIR_AUTOCLEAR Alarm clear: BHLIFTER AIR Auto 14580 BHLIFTER_AIR_MSTOPSET Alarm Set: BHLIFTER AIR Mstop 14581 BHLIFTER_AIR_MSTOPCLEAR Alarm clear: BHLIFTER AIR Mstop 14590 EH_INIT_FOCUS_MOTOR_ STEPPER_FAILED-SET Alarm Set: EH INIT Focus Motor Stepper Failed 14591 EH_INIT_FOCUS_MOTOR_ STEPPER_FAILED-CLEAR Alarm clear: EH INIT Focus Motor Stepper Failed 14600 EH_FATAL_IDX_NOT_FOU ND-SET Alarm Set: EH Fatal IDX Not Found 14601 EH_FATAL_IDX_NOT_FOU ND-CLEAR Alarm clear: EH Fatal IDX Not Found 14610 IND_NO_CLAMP_VACUUM _CONT-SET Alarm Set: IND NO Clamp Vacuum Cont 14611 IND_NO_CLAMP_VACUUM _CONT-CLEAR Alarm clear: IND NO Clamp Vacuum Cont 14620 IND_CLAMP_VACUUM_OF F_FAIL-SET Alarm Set: IND Clamp Vacuum OFF Fail 14621 IND_CLAMP_VACUUM_OF F_FAIL-CLEAR Alarm clear: IND Clamp Vacuum OFF Fail (U2) Page - 239 - of 321 Sep 18, 2020 Rev 4.1 Kulicke & Soffa™ SECS/GEM Interface for K&S Ball Bonders Bonder software version x-xx-x-472-series IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Collection Events CEID Name Description 14630 RAIL_LIMIT_AT_BONDSITE -SET Alarm Set: Rail Limit At Bondsite 14631 RAIL_LIMIT_AT_BONDSITE -CLEAR Alarm clear: Rail Limit At Bondsite 14640 RAIL_LIMIT_OUTSIDE_BO NDSITE-SET Alarm Set: Rail Limit Outside Bondsite 14641 RAIL_LIMIT_OUTSIDE_BO NDSITE-CLEAR Alarm clear: Rail Limit Outside Bondsite 14650 AUTO-WIRE-USAGEEXPIRY-SET Alarm Set: Auto Wire Usage Expiry 14651 AUTO-WIRE-USAGEEXPIRY-CLEAR Alarm clear: Auto Wire Usage Expiry 14660 EH-INSTALL-USB-COPYERROR-SET Alarm Set: EH Install USB Copy Error 14661 EH-INSTALL-USB-COPYERROR-CLEAR Alarm clear: EH Install USB Copy Error 14670 RWH_PN_CMD_FAILURESET Alarm Set: RWH PN CMD Failure 14671 RWH_PN_CMD_FAILURECLEAR Alarm clear: RWH PN CMD Failure 14680 MHS_INDEXER_EXCEED_ WHL_LIMIT-SET Alarm Set: MHS Indexer Exceed WHL Limit 14681 MHS_INDEXER_EXCEED_ WHL_LIMIT-CLEAR Alarm clear: MHS Indexer Exceed WHL Limit 14690 IMH_UNLOAD_FAIL-SET Alarm Set: IMH Unload Fail 14691 IMH_UNLOAD_FAIL-CLEAR Alarm clear: IMH Unload Fail 14700 OMH_UNLOAD_FAIL-SET Alarm Set: OMH Unload Fail 14701 OMH_UNLOAD_FAILCLEAR Alarm clear: OMH Unload Fail 14710 MH_WAIT_STORE_MAGSET Alarm Set: MH Wait Store MAG 14711 MH_WAIT_STORE_MAGCLEAR Alarm clear: MH Wait Store MAG 14720 MH_WAIT_STORE_MAG_O -SET Alarm Set: MH Wait Store MAG O 14721 MH_WAIT_STORE_MAG_O -CLEAR Alarm clear: MH Wait Store MAG O 14730 EJECT_INPUT_MAGAZINE _NOT_EMPTY-SET Alarm Set: Eject Input Magazine Not Empty (U2) Page - 240 - of 321 Sep 18, 2020 Rev 4.1 Kulicke & Soffa™ SECS/GEM Interface for K&S Ball Bonders Bonder software version x-xx-x-472-series IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Collection Events CEID Name Description 14731 EJECT_INPUT_MAGAZINE _NOT_EMPTY-CLEAR Alarm clear: Eject Input Magazine Not Empty 14740 MH_LOAD_MAG_PUSHER _PUSH_FAIL-SET Alarm Set: MH Load MAG Pusher Push Fail 14741 MH_LOAD_MAG_PUSHER _PUSH_FAIL-CLEAR Alarm clear: MH Load MAG Pusher Push Fail 14750 MH_LOAD_MAG_PUSHER _PUSH_FAIL_O-SET Alarm Set: MH Load MAG Pusher Push Fail O 14751 MH_LOAD_MAG_PUSHER _PUSH_FAIL_O-CLEAR Alarm clear: MH Load MAG Pusher Push Fail O 14760 MH_UNLOAD_MAG_PUSH ER_PUSH_FAIL-SET Alarm Set: MH Unload MAG Pusher Push Fail 14761 MH_UNLOAD_MAG_PUSH ER_PUSH_FAIL-CLEAR Alarm clear: MH Unload MAG Pusher Push Fail 14770 MH_UNLOAD_MAG_PUSH ER_PUSH_FAIL_O-SET Alarm Set: MH Unload MAG Pusher Push Fail O 14771 MH_UNLOAD_MAG_PUSH ER_PUSH_FAIL_O-CLEAR Alarm clear: MH Unload MAG Pusher Push Fail O 14780 MH_LOAD_MAG_PUSHER _RETRACT_FAIL-SET Alarm Set: MH Load MAG Pusher Retract Fail 14781 MH_LOAD_MAG_PUSHER _RETRACT_FAIL-CLEAR Alarm clear: MH Load MAG Pusher Retract Fail 14790 MH_LOAD_MAG_PUSHER _RETRACT_FAIL_O-SET Alarm Set: MH Load MAG Pusher Retract Fail O 14791 MH_LOAD_MAG_PUSHER _RETRACT_FAIL_OCLEAR Alarm clear: MH Load MAG Pusher Retract Fail O 14800 MH_UNLOAD_MAG_PUSH ER_RETRACT_FAIL-SET Alarm Set: MH Unload MAG Pusher Retract Fail 14801 MH_UNLOAD_MAG_PUSH ER_RETRACT_FAILCLEAR Alarm clear: MH Unload MAG Pusher Retract Fail 14810 MH_UNLOAD_MAG_PUSH ER_RETRACT_FAIL_OSET Alarm Set: MH Unload MAG Pusher Retract Fail O 14811 MH_UNLOAD_MAG_PUSH ER_RETRACT_FAIL_OCLEAR Alarm clear: MH Unload MAG Pusher Retract Fail O 14820 AUTO-LOCATOR-FINDFAIL-SET Alarm Set: Auto Locator Fine Fail (U2) Page - 241 - of 321 Sep 18, 2020 Rev 4.1 Kulicke & Soffa™ SECS/GEM Interface for K&S Ball Bonders Bonder software version x-xx-x-472-series IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Collection Events CEID Name Description 14821 AUTO-LOCATOR-FINDFAIL-CLEAR Alarm clear: Auto Locator Fine Fail 14830 STRIP_MAP_DL_TIMEOUTSET Alarm Set: Strip Map DL Time Out 14831 STRIP_MAP_DL_TIMEOUTCLEAR Alarm clear: Strip Map DL Time Out 14840 STRIP_MAP_DL_FAIL-SET Alarm Set: Strip Map DL Fail 14841 STRIP_MAP_DL_FAILCLEAR Alarm clear: Strip Map DL Fail 14850 STRIP_MAP_INVALID_SIZE -SET Alarm Set: Strip Map Invalid Size 14851 STRIP_MAP_INVALID_SIZE -CLEAR Alarm clear: Strip Map Invalid Size 14860 MHS_GRIP_THETA_BIAS_ FAIL-SET Alarm Set: MHS Grip Theta Bias Fail 14861 MHS_GRIP_THETA_BIAS_ FAIL-CLEAR Alarm clear: MHS Grip Theta Bias Fail 14870 EH-USB-PWS-MATROXDROP-SET Alarm Set: EH USB PWS Matrox Drop 14871 EH-USB-PWS-MATROXDROP-CLEAR Alarm clear: EH USB PWS Matrox Drop 14880 STRIP_MAP_INVALID_OR G_LOC-SET Alarm Set: Strip Map Invalid ORG LOC 14881 STRIP_MAP_INVALID_OR G_LOC-CLEAR Alarm clear: Strip Map Invalid ORG LOC 14890 PARAM_RULE_ERR-SET Alarm Set: Param Rule Error 14891 PARAM_RULE_ERRCLEAR Alarm clear: Param Rule Error 14900 EH_GUIDE_SENSOR_NOT _SAFE-SET Alarm Set: EH Guide Sensor Not Safe 14901 EH_GUIDE_SENSOR_NOT _SAFE-CLEAR Alarm clear: EH Guide Sensor Not Safe 14910 EH_GUIDE_SENSOR_NOT _SAFE_O-SET Alarm Set: EH Guide Sensor Not Safe O 14911 EH_GUIDE_SENSOR_NOT _SAFE_O-CLEAR Alarm clear: EH Guide Sensor Not Safe O 14920 NKG_DONGLE_CHECK_E RROR-SET Alarm Set: NKG Dongle Check Error 14921 NKG_DONGLE_CHECK_E RROR-CLEAR Alarm clear: NKG Dongle Check Error (U2) Page - 242 - of 321 Sep 18, 2020 Rev 4.1 Kulicke & Soffa™ SECS/GEM Interface for K&S Ball Bonders Bonder software version x-xx-x-472-series IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Collection Events CEID Name Description 14930 STRIP_MAP_HOST_REPLY _HALT-SET Alarm Set: Strip Map Host Reply Halt 14931 STRIP_MAP_HOST_REPLY _HALT-CLEAR Alarm clear: Strip Map Host Reply Halt 14940 RLS_UNBIAS_FAILED-SET Alarm Set: RLS UNBIAS Failed 14941 RLS_UNBIAS_FAILEDCLEAR Alarm clear: RLS UNBIAS Failed 14950 MON-UPS-LOW-BATTERYSET Alarm Set: MON UPS Low Battery 14951 MON-UPS-LOW-BATTERYCLEAR Alarm clear: MON UPS Low Battery 14960 PROCESS-BP-HIT-SET Alarm Set: Process BP HIT 14961 PROCESS-BP-HIT-CLEAR Alarm clear: Process BP HIT 14970 AUTO-DRP-CHECK-FAILSET Alarm Set: Auto DRP Check Fail 14971 AUTO-DRP-CHECK-FAILCLEAR Alarm clear: Auto DRP Check Fail 14980 EH_AUTO_TEMP_OVER_H I_LIMIT_LINK-SET Alarm Set: EH Auto Temp Over HI Limit Link 14981 EH_AUTO_TEMP_OVER_H I_LIMIT_LINK-CLEAR Alarm clear: EH Auto Temp Over HI Limit Link 14990 EH_AUTO_TEMP_UNDER_ LOW_LIMIT_LINK-SET Alarm Set: EH Auto Temp Under Low Limit Link 14991 EH_AUTO_TEMP_UNDER_ LOW_LIMIT_LINK-CLEAR Alarm clear: EH Auto Temp Under Low Limit Link 15000 EH_AUTO_TEMP_OVER_H I_LIMIT_OPTICS-SET Alarm Set: EH Auto Temp Over HI Limit Optics 15001 EH_AUTO_TEMP_OVER_H I_LIMIT_OPTICS-CLEAR Alarm clear: EH Auto Temp Over HI Limit Optics 15010 EH_AUTO_TEMP_UNDER_ LOW_LIMIT_OPTICS-SET Alarm Set: EH Auto Temp Under Low Limit Optics 15011 EH_AUTO_TEMP_UNDER_ LOW_LIMIT_OPTICSCLEAR Alarm clear: EH Auto Temp Under Low Limit Optics 15020 STRIP_MAP_HOST_REPLY _ERROR-SET Alarm Set: Strip Map Host Reply Error 15021 STRIP_MAP_HOST_REPLY _ERROR-CLEAR Alarm clear: Strip Map Host Reply Error 15030 EH_SUB_VALIDATION_FAI LED-SET Alarm Set: EH SUB Validation Failed (U2) Page - 243 - of 321 Sep 18, 2020 Rev 4.1 Kulicke & Soffa™ SECS/GEM Interface for K&S Ball Bonders Bonder software version x-xx-x-472-series IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Collection Events CEID Name Description 15031 EH_SUB_VALIDATION_FAI LED-CLEAR Alarm clear: EH SUB Validation Failed 15040 CAP_CLEANING_REACHIN G_LIMIT-SET Alarm Set: Cap Cleaning Reaching Limit 15041 CAP_CLEANING_REACHIN G_LIMIT-CLEAR Alarm clear: Cap Cleaning Reaching Limit 15050 EH_DISK_SPACE_FULLSET Alarm Set: EH Disk Space Full 15051 EH_DISK_SPACE_FULLCLEAR Alarm clear: EH Disk Space Full 15060 EH_DISK_SPACE_NOT_FU LL-SET Alarm Set: EH Disk Space Not Full 15061 EH_DISK_SPACE_NOT_FU LL-CLEAR Alarm clear: EH Disk Space Not Full 15070 EH_TEMP_OVER_MAX_LI MIT-SET Alarm Set: EH TEMP Over Max Limit 15071 EH_TEMP_OVER_MAX_LI MIT-CLEAR Alarm clear: EH TEMP Over Max Limit 15080 I2C_BUS_ERROR-SET Alarm Set: I2C BUS Error 15081 I2C_BUS_ERROR-CLEAR Alarm clear: I2C BUS Error 15090 PDT-PULLTST-INIT-ERRSET Set Pull Test initialization error 15091 PDT-PULLTST-INIT-ERRCLEAR Clear Pull Test initialization error 15100 CAL_XHAIR_MAP_ UNSUCCESSFUL-SET Alarm Set:CAL_XHAIR_MAP_ UNSUCCESSFUL-SET 15101 CAL_XHAIR_MAP_ UNSUCCESSFUL-CLEAR Alarm Clear:CAL_XHAIR_MAP_ UNSUCCESSFUL-Clear 15110 AUTO_COVER_GAS_BACK _PRESSURE_HIGH-SET Alarm Set: digital cover gas back pressure too high 15111 AUTO_COVER_GAS_BACK _PRESSURE_HIGH-CLEAR Alarm Clear: digital cover gas back pressure too high 15120 AUTO_COVER_GAS_BACK _PRESSURE_LOW-SET Alarm Set: digital cover gas back pressure too low 15121 AUTO_COVER_GAS_BACK _PRESSURE_LOW-CLEAR Alarm Clear: Set digital cover gas back pressure too low 15130 PDT-UNEXPECTED-NSOPTIP2-SET Alarm Set: PDT Unexpected NSOP TIP2 15131 PDT-UNEXPECTED-NSOPTIP2-CLEAR Alarm Clear: PDT Unexpected NSOP TIP2 (U2) Page - 244 - of 321 Sep 18, 2020 Rev 4.1 Kulicke & Soffa™ SECS/GEM Interface for K&S Ball Bonders Bonder software version x-xx-x-472-series IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Collection Events CEID Name Description 15140 EH-PDT-LGBALL-SET Alarm Set: EH-PDT-LGBALL 15141 EH-PDT-LGBALL-CLEAR Alarm Clear: EH-PDT-LGBALL 15150 EH_HB_HIT_RAIL_LIMIT_S WITCH-SET Alarm Set:EH_HB_HIT_RAIL_LIMIT_SWITCH 15151 EH_HB_HIT_RAIL_LIMIT_S WITCH-CLEAR Alarm Clear:EH_HB_HIT_RAIL_LIMIT_SWITCH 15160 EH_BALL_TAIL_INVALIDAT ION-SET Alarm Set:EH_BALL_TAIL_INVALIDATION 15161 EH_BALL_TAIL_INVALIDAT ION-CLEAR Alarm Clear:EH_BALL_TAIL_INVALIDATION 15170 EH_STRIP_MAP_INVALIDSET Alarm Set:EH_STRIP_MAP_INVALID 15171 EH_STRIP_MAP_INVALIDCLEAR Alarm Clear:EH_STRIP_MAP_INVALID 15180 EH_NFS_MOUNT_FAIL_ER ROR-SET Alarm Set:EH-NFS-MOUNT-FAIL-ERROR 15181 EH_NFS_MOUNT_FAIL_ER ROR-CLEAR Alarm Clear:EH-NFS-MOUNT-FAIL-ERROR 15190 EH_NSOL_AUTO_REBOND _ATTEMPTED-SET Alarm Set:EH_NSOL_AUTO_REBOND_ATTEMPTED 15191 EH_NSOL_AUTO_REBOND _ATTEMPTED-CLEAR Alarm Clear:EH_NSOL_AUTO_REBOND_ATTEMPTED 15200 EH_NSOL_AUTO_REBOND _FAILED-SET Alarm Set:EH_NSOL_AUTO_REBOND_FAILED 15201 EH_NSOL_AUTO_REBOND _FAILED-CLEAR Alarm Clear:EH_NSOL_AUTO_REBOND_FAILED 15210 PUSHER_KIT_RETRACT_F AILURE-SET Alarm Set: PUSHER_KIT_RETRACT_FAILURE 15211 PUSHER_KIT_RETRACT_F AILURE-CLEAR Alarm Clear: PUSHER_KIT_RETRACT_FAILURE 15220 EH_UNKNOWN_CELL_VER IFICATION-SET Alarm Set:EH_UNKNOWN_CELL_VERIFICATION 15221 EH_UNKNOWN_CELL_VER IFICATION-CLEAR Alarm Clear:EH_UNKNOWN_CELL_VERIFICATION 15230 CE_AUTO-ALIGN-FINDFAIL-PARTIAL-BONDEDDEV-SET Alarm Set:CEID for setting event #2322 15231 CE_AUTO-ALIGN-FINDFAIL-PARTIAL-BONDEDDEV-CLEAR Alarm Clear:CEID for clearing event #2322 (U2) Page - 245 - of 321 Sep 18, 2020 Rev 4.1 Kulicke & Soffa™ SECS/GEM Interface for K&S Ball Bonders Bonder software version x-xx-x-472-series IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Collection Events CEID Name Description 15240 WIRE_CLAMP_PM_LIMIT_ EXCEEDED _SET Alarm Set:Wire Clamp Usage Reached Limit Set 15241 WIRE_CLAMP_PM_LIMIT_ EXCEEDED _CLEAR Alarm Clear:Wire Clamp Usage Reached Limit Clear 15250 EH_SAFETY_COVER_KIT_ FAILURE-SET Alarm Set:Set Safety Cover Error 15251 EH_SAFETY_COVER_KIT_ FAILURE-CLEAR Alarm Clear:Clear Safety Cover Error 15260 FLUID_RATE_OUT_OF_LI MIT_SET Alarm Set:Fluid rate out of limit set 15261 FLUID_RATE_OUT_OF_LI MIT_CLEAR Alarm Clear:Fluid rate out of limit clear 15270 EH_PRH_VACUUM_ON_FA IL-SET Alarm Set:Set Preheat Vacuum is not present Error 15271 EH_PRH_VACUUM_ON_FA IL-CLEAR Alarm Clear:Clear Preheat Vacuum is not present Error 15280 EH_RAILS_HOME_SEEK_F AIL-SET Alarm Set:Set Rails Home Seek Fail Error 15281 EH_RAILS_HOME_SEEK_F AIL-CLEAR Alarm Clear:Clear Rails Home Seek Fail Error 15290 EH_AIR_BLOWER_OUTOF _LIMIT_W_CONT-SET Alarm Set:Air Blower Flow Rate Out Of Limit 15291 EH_AIR_BLOWER_OUTOF _LIMIT_W_CONT-CLEAR Alarm Clear:Air Blower Flow Rate Out Of Limit 15300 EH_AIR_BLOWER_OUTOF _LIMIT-SET Alarm Set:Air Blower Flow Rate Out Of Limit 15301 EH_AIR_BLOWER_OUTOF _LIMIT-CLEAR Alarm Clear:Air Blower Flow Rate Out Of Limit 15310 EH_ORIENT_EYE_POINT_ NOT_FOUND-SET Search Orientation eye point failded 15311 EH_ORIENT_EYE_POINT_ NOT_FOUND-CLEAR Search Orientation eye point failded 15320 EH_PERIODIC_EFO_HEIG H_CHECK_FAIL-SET Set CEID of periodic EFO height calibration fails 15321 EH_PERIODIC_EFO_HEIG H_CHECK_FAIL-CLEAR Clear CEID of periodic EFO height calibration fails 15330 EH_PERIODIC_EFO_HEIG H_CHECK_OUT_OF_LIMITSET Set CEID of periodic EFO height calibration out of limit (U2) Page - 246 - of 321 Sep 18, 2020 Rev 4.1 Kulicke & Soffa™ SECS/GEM Interface for K&S Ball Bonders Bonder software version x-xx-x-472-series IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Collection Events CEID Name Description 15331 EH_PERIODIC_EFO_HEIG H_CHECK_OUT_OF_LIMITCLEAR Clear CEID of periodic EFO height calibration out of limit 15340 CE_SOS_EVENT-SET Set SOS_EVENT (alarm) 15341 CE_SOS_EVENT-CLEAR Clear SOS_EVENT (alarm) 15350 EH_MHS_OHT_EXEC_SEQ _ERR-SET Set OHT Sequence Failure 15351 EH_MHS_OHT_EXEC_SEQ _ERR-CLEAR Clear OHT Sequence Failure 15360 EH_INPUT_MAG_EJECT_I NHIBITED-SET Event indicate EH error EH_INPUT_MAG_EJECT_INHIBITED is pop up on GUI 15361 EH_INPUT_MAG_EJECT_I NHIBITED-CLEAR Event indicate EH error EH_INPUT_MAG_EJECT_INHIBITED is pop down on GUI 15370 EH_OUTPUT_MAG_EJECT _INHIBITED-SET Event indicate EH error EH_OUTPUT_MAG_EJECT_INHIBITED is pop up on GUI 15371 EH_OUTPUT_MAG_EJECT _INHIBITED-CLEAR Event indicate EH error EH_OUTPUT_MAG_EJECT_INHIBITED is pop down on GUI 15380 EH_INPUT_MAG_EJECT_H OST_VALIDATION_TIMEO UT-SET Event indicate EH error EH_INPUT_MAG_EJECT_HOST_VALIDATION_TIMEOUT is pop up on GUI 15381 EH_INPUT_MAG_EJECT_H OST_VALIDATION_TIMEO UT-CLEAR Event indicate EH error EH_INPUT_MAG_EJECT_HOST_VALIDATION_TIMEOUT is pop down on GUI 15390 EH_OUTPUT_MAG_EJECT _HOST_VALIDATION_TIME OUT-SET Event indicate EH error EH_OUTPUT_MAG_EJECT_HOST_VALIDATION_TIMEOUT is pop up on GUI 15391 EH_OUTPUT_MAG_EJECT _HOST_VALIDATION_TIME OUT-CLEAR Event indicate EH error EH_OUTPUT_MAG_EJECT_HOST_VALIDATION_TIMEOUT is pop down on GUI 15400 EH_WEDGE_VALIDATION_ CHECK_FAIL-SET Alarm Set:EH_WEDGE_VALIDATION_CHECK_FAIL 15401 EH_WEDGE_VALIDATION_ CHECK_FAIL-CLEAR Alarm Clear:EH_WEDGE_VALIDATION_CHECK_FAIL 15420 EH_SUBSTRATE_MAP_PA RSE_FAIL-SET Alarm Set:Parse Substrate Map Failed 15421 EH_SUBSTRATE_MAP_PA RSE_FAIL-CLEAR Alarm Clear:Parse Substrate Map Failed 15430 CMP_COVER_HOME_NOT _FOUND-SET Set Clamp cover home not found error 15431 CMP_COVER_HOME_NOT _FOUND-CLEAR Clear Clamp cover home not found Error (U2) Page - 247 - of 321 Sep 18, 2020 Rev 4.1 Kulicke & Soffa™ SECS/GEM Interface for K&S Ball Bonders Bonder software version x-xx-x-472-series IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Collection Events CEID Name Description 15440 CMP_COVER_NOT_OUT_ OF_HOME-SET Set Clamp cover is not out of home error 15441 CMP_COVER_NOT_OUT_ OF_HOME-CLEAR Clear Clamp cover is not out of home Error 15450 EH_HB_SECURE_VACUU M_FAIL-SET Set EH_HB_SECURE_VACUUM_FAIL error 15451 EH_HB_SECURE_VACUU M_FAIL-CLEAR Clear EH_HB_SECURE_VACUUM_FAIL error 15460 EH_GCK_GAS_LOW-SET Set EH_GCK_GAS_LOW 15461 EH_GCK_GAS_LOWCLEAR Clear EH_GCK_GAS_LOW 15470 EH_GCK_GAS_LOW_IN_B ONDING-SET Set EH_GCK_GAS_LOW_IN_BONDING 15471 EH_GCK_GAS_LOW_IN_B ONDING-CLEAR Clear EH_GCK_GAS_LOW_IN_BONDING 15480 EH_MAG_MOTION_INTER RUPT-SET Set magazine motion interrupt error 15481 EH_MAG_MOTION_INTER RUPT-CLEAR Clear magazine motion interrupt error 15490 PUSHER_KIT_HOME_SEN SOR_ERROR-SET Alarm set: Pusher Kit home sensor has some error 15491 PUSHER_KIT_HOME_SEN SOR_ERROR-CLEAR Alarm clear: Pusher Kit home sensor has some error 15500 EH_FOCUS_ADJ_OUT_OF _LIMIT-SET Set for EH #2378 15501 EH_FOCUS_ADJ_OUT_OF _LIMIT-CLEAR Clear for EH #2378 15510 EH_PDT_RPMOUTLIER_E RROR-SET Alarm set: RPM single-outlier error triggered 15511 EH_PDT_RPMOUTLIER_E RROR-CLEAR Alarm clear: RPM single-outlier error cleared 15520 EH_CNG_BOND_COUNTE RS_EXCEEDED-SET Alarm set: configured bond counter limit exceed 15521 EH_CNG_BOND_COUNTE RS_EXCEEDED-CLEAR Alarm clear: configured bond counter limit exceed 15530 EH_CNG_BOND_COUNTE RS_STOP_AUTO-SET Alarm set: configured bond counter limit exceed and stop auto 15531 EH_CNG_BOND_COUNTE RS_STOP_AUTO-CLEAR Alarm clear: configured bond counter limit exceed and stop auto 15540 EH_FAINT6_GUI_ERR-SET Set notification “GUI Task Exception. Machine reboot is required” (U2) Page - 248 - of 321 Sep 18, 2020 Rev 4.1 Kulicke & Soffa™ SECS/GEM Interface for K&S Ball Bonders Bonder software version x-xx-x-472-series IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Collection Events CEID Name Description 15541 EH_FAINT6_GUI_ERRCLEAR Clear notification, “GUI Task Exception. Machine reboot is required” 15550 EH_REALTIME_RPM_ERR OR-SET Realtime RPM error set 15551 EH_REALTIME_RPM_ERR OR-CLEAR Realtime RPM error clear 15560 EH_CLXC_BASE_TEMP_T HRESHOLD_EXCEEDEDSET Set CLXC base temperature threshold exceeded error 15561 EH_CLXC_BASE_TEMP_T HRESHOLD_EXCEEDEDCLEAR Clear CLXC base temperature threshold exceeded error 15570 EH_MH_CHUTE_CLAMP_F AILED-SET Set EH_MH_CHUTE_CLAMP_FAILED 15571 EH_MH_CHUTE_CLAMP_F AILED-CLEAR Clear EH_MH_CHUTE_CLAMP_FAILED 15580 EH_MH_CHUTE_CLAMP_F AILED_O-SET Set EH_MH_CHUTE_CLAMP_FAILED_O 15581 EH_MH_CHUTE_CLAMP_F AILED_O-CLEAR Clear EH_MH_CHUTE_CLAMP_FAILED_O 15590 STRIP_ID_NOT_FOUND_IN _LOCAL_SERVER-SET Set alarm of strip ID not found in local server 15591 STRIP_ID_NOT_FOUND_IN _LOCAL_SERVER-CLEAR Clear alarm of strip ID not found in local server 15600 PDT-DIE-HEIGHT-OVERLIMIT-SET Set PDT DIE Height Over Limit error 15601 PDT-DIE-HEIGHT-OVERLIMIT-CLEAR Clear PDT DIE Height Over Limit error 15610 BATTERY_MISMATCH_SE TTING-SET Alarm set: BATTERY_MISMATCH_SETTING 15611 BATTERY_MISMATCH_SE TTING-CLEAR Alarm clear: BATTERY_MISMATCH_SETTING 15620 AUTO_CALIBRATION_NEA R_EXPIRATION-SET Calibration near expiration has been set. 15621 AUTO_CALIBRATION_NEA R_EXPIRATION-CLEAR Calibration near expiration has been cleared 15630 AUTO_CALIBRATION_EXPI RED-SET Calibration expired has been set. 15631 AUTO_CALIBRATION_EXPI RED-CLEAR Calibration expired has been cleared (U2) Page - 249 - of 321 Sep 18, 2020 Rev 4.1 Kulicke & Soffa™ SECS/GEM Interface for K&S Ball Bonders Bonder software version x-xx-x-472-series IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Collection Events CEID Name Description 15640 AUTO_CALIBRATION_EXPI RED_STOP_INJECT-SET Calibration expired with stop strip inject has been set. 15641 AUTO_CALIBRATION_EXPI RED_STOP_INJECTCLEAR Calibration expired with stop strip inject has been cleared. 15650 MDS_FAULT_DETECTEDSET Machine Data Collection Fault 15651 MDS_FAULT_DETECTEDCLEAR Machine Data Collection Fault 15660 MH_BUFFER_RAIL_NOT_E MPTY-SET Set MH_BUFFER_RAIL_NOT_EMPTY 15661 MH_BUFFER_RAIL_NOT_E MPTY-CLEAR Clear MH_BUFFER_RAIL_NOT_EMPTY 15670 MH_BUFFER_RAIL_NOT_E MPTY_O-SET Set MH_BUFFER_RAIL_NOT_EMPTY_0 15671 MH_BUFFER_RAIL_NOT_E MPTY_O-CLEAR Clear MH_BUFFER_RAIL_NOT_EMPTY_0 15680 MH_INDEXER_RAIL_NOT_ EMPTY-SET Set MH_INDEXER_RAIL_NOT_EMPTY 15681 MH_INDEXER_RAIL_NOT_ EMPTY-CLEAR Clear MH_INDEXER_RAIL_NOT_EMPTY 15690 MH_INDEXER_RAIL_NOT_ EMPTY_O-SET Set MH_INDEXER_RAIL_NOT_EMPTY_0 15691 MH_INDEXER_RAIL_NOT_ EMPTY_O-CLEAR Clear MH_INDEXER_RAIL_NOT_EMPTY_0 15700 MH_BUFFER_RAIL_CRR_N OT_READY-SET Set MH_BUFFER_RAIL_CRR_NOT_READY 15701 MH_BUFFER_RAIL_CRR_N OT_READY-CLEAR Clear MH_BUFFER_RAIL_CRR_NOT_READY 15710 MH_BUFFER_RAIL_CRR_N OT_READY_O-SET Set MH_BUFFER_RAIL_CRR_NOT_READY_0 15711 MH_BUFFER_RAIL_CRR_N OT_READY_O-CLEAR Clear MH_BUFFER_RAIL_CRR_NOT_READY_0 15720 MH_INDEXER_RAIL_CRR_ NOT_READY-SET Set MH_INDEXER_RAIL_CRR_NOT_READY 15721 MH_INDEXER_RAIL_CRR_ NOT_READY-CLEAR Clear MH_INDEXER_RAIL_CRR_NOT_READY 15730 MH_INDEXER_RAIL_CRR_ NOT_READY_O-SET Set MH_INDEXER_RAIL_CRR_NOT_READY_0 15731 MH_INDEXER_RAIL_CRR_ NOT_READY_O-CLEAR Clear MH_INDEXER_RAIL_CRR_NOT_READY_0 (U2) Page - 250 - of 321 Sep 18, 2020 Rev 4.1 Kulicke & Soffa™ SECS/GEM Interface for K&S Ball Bonders Bonder software version x-xx-x-472-series IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Collection Events CEID Name Description 15750 EH_COMM_DOWN_BEFOR E_UPLOAD_STRIP_MAPSET Set CEID for ALID EH_COMM_DOWN_BEFORE_UPLOAD_STRIP_MAP 15751 EH_COMM_DOWN_BEFOR E_UPLOAD_STRIP_MAPCLEAR Clear CEID for ALID EH_COMM_DOWN_BEFORE_UPLOAD_STRIP_MAP 15760 PDT_UNEXPECTED_NSOP _MISSING_BOND-SET Missing bond detected by bond monitor has been set. 15761 PDT_UNEXPECTED_NSOP _MISSING_BOND-CLEAR Missing bond detected by bond monitor has been cleared 15770 EH_STITCH_LIFT_DETECT ED-SET Set event lifted stitch bond is detected by Stitch Lift Detection Feature 15771 EH_STITCH_LIFT_DETECT ED-CLEAR Clear event lifted stitch bond is detected by Stitch Lift Detection Feature 15780 ACCESS_VIOLATION_INP UT_LOAD-SET ACCESS_VIOLATION_INPUT_LOAD set 15781 ACCESS_VIOLATION_INP UT_LOAD-CLEAR ACCESS_VIOLATION_INPUT_LOAD clear 15790 ACCESS_VIOLATION_OUT PUT_LOAD-SET ACCESS_VIOLATION_OUTPUT_LOAD set 15791 ACCESS_VIOLATION_OUT PUT_LOAD-CLEAR ACCESS_VIOLATION_OUTPUT_LOAD clear 15800 PDT-UNEXPECTEDSTITCH-LIFT-SET Set PDT Stitch Lift error 15801 PDT-UNEXPECTEDSTITCH-LIFT-CLEAR Clear PDT Stitch Lift error 15810 PDT-UNEXPECTEDSTITCH-BREAK-SET Set PDT Stitch Break error 15811 PDT-UNEXPECTEDSTITCH- BREAK-CLEAR Clear PDT Stitch Break error 15820 PDT-UNEXPECTEDSTITCH-LIFT-BREAK-SET Set PDT Stitch Lift/Break error 15821 PDT-UNEXPECTEDSTITCH-LIFT-BREAKCLEAR Clear PDT Stitch Lift/Break error 15830 MDS_DATA_PURGE_EVEN T-SET User warning before purging machine data 15831 MDA_DATA_PURGE_EVEN T-CLEAR Clear user warning 15840 EH_INVALID_STRIP_MAPSET CEID triggered when strip map download failed (U2) Page - 251 - of 321 Sep 18, 2020 Rev 4.1 Kulicke & Soffa™ SECS/GEM Interface for K&S Ball Bonders Bonder software version x-xx-x-472-series IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Collection Events CEID Name Description 15841 EH_INVALID_STRIP_MAPCLEAR CEID triggered when strip map download failed 15850 KNS_CONNECT_ERRORSET Set KNS Connect error 15851 KNS_CONNECT_ERRORCLEAR Clear KNS Connect error 15860 EH_LAST_WIRE_NSOL_RE BOND_BEF_SKIP_DEVSET Set Last Wire NSOL Rebond Bef Skip Dev Warning Error 15861 EH_LAST_WIRE_NSOL_RE BOND_BEF_SKIP_DEVCLEAR Clear Last Wire NSOL Rebond Bef Skip Dev Warning Error 15870 EH_AUTO_LHM_MAX_LOO P_HT_EXCEED_WARN_LI MIT-SET Alarm Set: Max Loop Height exceeds Warning Limit 15871 EH_AUTO_LHM_MAX_LOO P_HT_EXCEED_WARN_LI MIT-CLEAR Alarm Clear: Max Loop Height exceeds Warning Limit 15880 EH_AUTO_LHM_MAX_LOO P_HT_EXCEED_ERR_LIMI T-SET Alarm Set: Max Loop Height exceeds Error Limit 15881 EH_AUTO_LHM_MAX_LOO P_HT_EXCEED_ERR_LIMI T-CLEAR Alarm Clear: Max Loop Height exceeds Error Limit 15890 EH_AUTO_LHM_EDGE_HE IGHT_EXCEED_WARN_LIM IT-SET Alarm Set: Edge Height exceeds Warning Limit 15891 EH_AUTO_LHM_EDGE_HE IGHT_EXCEED_WARN_LIM IT-CLEAR Alarm Clear: Edge Height exceeds Warning Limit 15900 EH_AUTO_LHM_EDGE_HE IGHT_EXCEED_ERR_LIMIT -SET Alarm Set: Edge Height exceeds Error Limit 15901 EH_AUTO_LHM_EDGE_HE IGHT_EXCEED_ERR_LIMIT -CLEAR Alarm Clear: Edge Height exceeds Error Limit 15910 EH_AUTO_LHM_RESULT_ VALIDATION_TIMEOUTSET Alarm Set: Result validation timeout 15911 EH_AUTO_LHM_RESULT_ VALIDATION_TIMEOUTCLEAR Alarm Clear: Result validation timeout (U2) Page - 252 - of 321 Sep 18, 2020 Rev 4.1 Kulicke & Soffa™ SECS/GEM Interface for K&S Ball Bonders Bonder software version x-xx-x-472-series IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Collection Events CEID Name Description 15920 EH_AUTO_LHM_RESULT_ VALIDATION_FAILED-SET Alarm Set: Result validation failed 15921 EH_AUTO_LHM_RESULT_ VALIDATION_FAILEDCLEAR Alarm Clear: Result validation failed 15930 EH_AUTO_LHM_RESULT_ VALIDATION_REJECTEDSET Alarm Set: Result rejected by host 15931 EH_AUTO_LHM_RESULT_ VALIDATION_REJECTEDCLEAR Alarm Clear: Result rejected by host 15940 MH_MAG_SEPARATION_E RR-SET SETCE for MH_MAG_SEPARATION_ERR 15941 MH_MAG_SEPARATION_E RR-CLEAR SETCE for MH_MAG_SEPARATION_ERR 15950 MH_MAG_SEPARATION_E RR_O-SET SETCE for MH_MAG_SEPARATION_ERR_O 15951 MH_MAG_SEPARATION_E RR_O-CLEAR SETCE for MH_MAG_SEPARATION_ERR_O 15960 MH_PLATFORM_NOT_EM PTY-SET Set MH_PLATFORM_NOT_EMPTY 15961 MH_PLATFORM_NOT_EM PTY-CLEAR Clear MH_PLATFORM_NOT_EMPTY 15970 MH_PLATFORM_NOT_EM PTY_O-SET Set MH_PLATFORM_NOT_EMPTY_O 15971 MH_PLATFORM_NOT_EM PTY_O-CLEAR Clear MH_PLATFORM_NOT_EMPTY_O 15980 MH_FORK_NOT_EMPTYSET Set MH_FORK_NOT_EMPTY 15981 MH_FORK_NOT_EMPTYCLEAR Clear MH_FORK_NOT_EMPTY 15990 MH_FORK_NOT_EMPTY_O -SET Set MH_FORK_NOT_EMPTY_O 15991 MH_FORK_NOT_EMPTY_O -CLEAR Clear MH_FORK_NOT_EMPTY_O 16000 MH_PLATFORM_CRR_NO T_READY-SET Set MH_PLATFORM_CRR_NOT_READY 16001 MH_PLATFORM_CRR_NO T_READY-CLEAR Clear MH_PLATFORM_CRR_NOT_READY 16010 MH_PLATFORM_CRR_NO T_READY_O-SET Set MH_PLATFORM_CRR_NOT_READY_O (U2) Page - 253 - of 321 Sep 18, 2020 Rev 4.1 Kulicke & Soffa™ SECS/GEM Interface for K&S Ball Bonders Bonder software version x-xx-x-472-series IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Collection Events CEID Name Description 16011 MH_PLATFORM_CRR_NO T_READY_O-CLEAR Clear MH_PLATFORM_CRR_NOT_READY_O 16020 MH_FOKR_CRR_NOT_REA DY-SET Set MH_FOKR_CRR_NOT_READY 16021 MH_FOKR_CRR_NOT_REA DY-CLEAR Clear MH_FOKR_CRR_NOT_READY 16030 MH_FOKR_CRR_NOT_REA DY_O-SET Set MH_FOKR_CRR_NOT_READY_O 16031 MH_FOKR_CRR_NOT_REA DY_O-CLEAR Clear MH_FOKR_CRR_NOT_READY_O 16040 LOADER_BENCH_SEQ_ER ROR-SET Set LOADER_BENCH_SEQ_ERROR 16041 LOADER_BENCH_SEQ_ER ROR-CLEAR Clear LOADER_BENCH_SEQ_ERROR 16050 EH_SAFETY_INIT_FAILEDSET Safety module initialize failed set 16051 EH_SAFETY_INIT_FAILEDCLEAR Safety module initialize failed clear 16060 EH_NSOL_REBOND_BEF_ SKIP_DEV_FAILED-SET Alarm Set: EH_NSOL_REBOND_BEF_ SKIP_DEV_FAILED-CLEAR Alarm Clear: 16070 AIR_OUT_OF_TOLERANC E-SET Air pressure tolerance exceeded 16071 AIR_OUT_OF_TOLERANC E-CLEAR Air pressure tolerance exceeded 16080 EH_OUTPUT_KICK_HOME _NOT_FOUND-SET Output kicker home not found 16081 EH_OUTPUT_KICK_HOME _NOT_FOUND-CLEAR Output kicker home not found 16090 EH_OUTPUT_KICK_NOT_ OUT_OF_HOME -SET Output kicker not out of home 16091 EH_OUTPUT_KICK_NOT_ OUT_OF_HOME -CLEAR Output kicker not out of home 16100 EH_LEFT_CLAW_HOME_N OT_FOUND-SET Left claw home not found 16101 EH_LEFT_CLAW_HOME_N OT_FOUND-CLEAR Left claw home not found 16110 EH_LEFT_CLAW_NOT_OU T_OF_HOME-SET Left claw not out of home (U2) 16061 NSOL Rebond Before Skip Device Failed NSOL Rebond Before Skip Device Failed Page - 254 - of 321 Sep 18, 2020 Rev 4.1 Kulicke & Soffa™ SECS/GEM Interface for K&S Ball Bonders Bonder software version x-xx-x-472-series IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Collection Events CEID Name Description 16111 EH_LEFT_CLAW_NOT_OU T_OF_HOME-CLEAR Left claw not out of home 16120 EH_RIGHT_CLAW_HOME_ NOT_FOUND-SET Right claw home not found 16121 EH_RIGHT_CLAW_HOME_ NOT_FOUND-CLEAR Right claw home not found 16130 EH_RIGHT_CLAW_NOT_O UT_OF_HOME-SET Right claw not out of home 16131 EH_RIGHT_CLAW_NOT_O UT_OF_HOME-CLEAR Right claw not out of home 16140 EH_INPUT_KICK_HOME_N OT_FOUND-SET Input kicker home not found 16141 EH_INPUT_KICK_HOME_N OT_FOUND-CLEAR Input kicker home not found 16150 EH_INPUT_KICK_NOT_OU T_OF_HOME-SET Input kicker not out of home 16151 EH_INPUT_KICK_NOT_OU T_OF_HOME-CLEAR Input kicker not out of home 16160 EH_BK_CLAMP_HOME_NO T_FOUND-SET Clamp home not found 16161 EH_BK_CLAMP_HOME_NO T_FOUND-CLEAR Clamp home not found 16170 EH_DOUBLE_LF_DETECT ED-SET Double LF detected 16171 EH_DOUBLE_LF_DETECT ED-CLEAR Double LF detected 16180 EH_INPUT_LF_JAM-SET Input LF jammed 16181 EH_INPUT_LF_JAM-CLEAR Input LF jammed 16190 EH_MH_MAG_NOT_ON_IN DEXER-SET Input mag not on indexer 16191 EH_MH_MAG_NOT_ON_IN DEXER-CLEAR Input mag not on indexer 16200 EH_MH_MAG_NOT_ON_IN DEXER_O-SET Output mag not on indexer 16201 EH_MH_MAG_NOT_ON_IN DEXER_O-CLEAR Output mag not on indexer 16210 CE_SOS_EVENT Inform Host on an SOS Event – i.e. A CPU- or OS fault or critical deadloop 16211 CE_ALIVE_EVENT Alive Event: Inform Host that No CPU-Fault or OS-Fault or Critical Deadloop has been detected during the Check (U2) Page - 255 - of 321 Sep 18, 2020 Rev 4.1 Kulicke & Soffa™ SECS/GEM Interface for K&S Ball Bonders Bonder software version x-xx-x-472-series IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Collection Events CEID Name Description 16220 EH_MH_MAG_WRONG_OR IENTATION-SET Input mag wrong oritentation 16221 EH_MH_MAG_WRONG_OR IENTATION-CLEAR Input mag wrong oritentation 16230 EH_MH_MAG_WRONG_OR IENTATION_O-SET Output mag wrong orientation 16231 EH_MH_MAG_WRONG_OR IENTATION_O-CLEAR Output mag wrong orientation 16240 EH_MH_MAGAZINE_DROP PED-SET Input mag dropped 16241 EH_MH_MAGAZINE_DROP PED-CLEAR Input mag dropped 16250 EH_MH_MAGAZINE_DROP PED_O-SET Output mag dropped 16251 EH_MH_MAGAZINE_DROP PED_O-CLEAR Output mag dropped 16260 PDT-EFO-THRESHOLDFAULT-SET Set Event EFO Limit Exceeded Fault 16261 PDT-EFO-THRESHOLDFAULT-CLEAR Clear Event EFO Limit Exceeded Fault 16270 EH_PART_REJECTED_BY_ HOST-SET Alarm set: EH_PART_REJECTED_BY_HOST 16271 EH_PART_REJECTED_BY_ HOST-CLEAR Alarm clear: EH_PART_REJECTED_BY_HOST 16280 EH_PART_BLOCKED_BY_ HOST-SET Alarm set: EH_PART_BLOCKED_BY_HOST 16281 EH_PART_BLOCKED_BY_ HOST-CLEAR Alarm clear: EH_PART_WARNING_BY_ HOST-SET Alarm set: EH_PART_WARNING_BY_ HOST-CLEAR Alarm clear: EH_PART_MAP_DLOAD_TI MEOUT-SET Alarm set: EH_PART_MAP_DLOAD_TI MEOUT-CLEAR Alarm clear: EH_PART_MAP_DLOAD_F AIL-SET Alarm set: (U2) 16290 16291 16300 16301 16310 EH_PART_BLOCKED_BY_HOST EH_PART_WARNING_BY_HOST EH_PART_WARNING_BY_HOST EH_PART_MAP_DLOAD_TIMEOUT EH_PART_MAP_DLOAD_TIMEOUT EH_PART_MAP_DLOAD_FAIL Page - 256 - of 321 Sep 18, 2020 Rev 4.1 Kulicke & Soffa™ SECS/GEM Interface for K&S Ball Bonders Bonder software version x-xx-x-472-series IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Collection Events CEID Name Description EH_PART_MAP_DLOAD_F AIL-CLEAR Alarm clear: PART_PROCESS_RSLT_R EJECTED_BY_HOST-SET Alarm set: PART_PROCESS_RSLT_R EJECTED_BY_HOSTCLEAR Alarm clear: PART_PROCESS_RSLT_V ALIDATION_TIMEOUT-SET Alarm set: PART_PROCESS_RSLT_V ALIDATION_TIMEOUTCLEAR Alarm clear: 16350 EH_WALL_SENSOR_CHEC K_FAIL_DURING_EJECT_L F -SET Set CEID for ALID EH_WALL_SENSOR_CHECK_FAIL_DURING_EJECT_LF 16351 EH_WALL_SENSOR_CHEC K_FAIL_DURING_EJECT_L F -CLEAR Clear CEID for ALID EH_WALL_SENSOR_CHECK_FAIL_DURING_EJECT_LF 16360 INPUT_CONVEYOR_COM M_ERROR-SET Set INPUT_CONVEYOR_COMM_ERROR 16361 INPUT_CONVEYOR_COM M_ERROR-CLEAR Clear INPUT_CONVEYOR_COMM_ERROR 16370 OUTPUT_CONVEYOR_CO MM_ERROR-SET Set OUTPUT_CONVEYOR_COMM_ERROR 16371 OUTPUT_CONVEYOR_CO MM_ERROR-CLEAR Clear OUTPUT_CONVEYOR_COMM_ERROR 16380 INPUT_CONVEYOR_COM M_TIMEOUT-SET Set INPUT_CONVEYOR_COMM_TIMEOUT 16381 INPUT_CONVEYOR_COM M_TIMEOUT-CLEAR Clear INPUT_CONVEYOR_COMM_TIMEOUT 16390 OUTPUT_CONVEYOR_CO MM_TIMEOUT-SET Set OUTPUT_CONVEYOR_COMM_TIMEOUT 16391 OUTPUT_CONVEYOR_CO MM_TIMEOUT-CLEAR Clear OUTPUT_CONVEYOR_COMM_TIMEOUT 16400 INPUT_CONVEYOR_ERRO R-SET Set INPUT_CONVEYOR_ERROR 16401 INPUT_CONVEYOR_ERRO R-CLEAR Clear INPUT_CONVEYOR_ERROR 16410 OUTPUT_CONVEYOR_ER ROR-SET Set OUTPUT_CONVEYOR_ERROR (U2) 16311 16320 16321 16330 16331 EH_PART_MAP_DLOAD_FAIL PART_PROCESS_RSLT_REJECTED_BY_HOST PART_PROCESS_RSLT_REJECTED_BY_HOST PART_PROCESS_RSLT_VALIDATION_TIMEOUT PART_PROCESS_RSLT_VALIDATION_TIMEOUT Page - 257 - of 321 Sep 18, 2020 Rev 4.1 Kulicke & Soffa™ SECS/GEM Interface for K&S Ball Bonders Bonder software version x-xx-x-472-series IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Collection Events CEID Name Description 16411 OUTPUT_CONVEYOR_ER ROR-CLEAR Clear OUTPUT_CONVEYOR_ERROR 16420 INPUT_CONVEYOR_WAIT_ UPSTREAM_TIMEOUT-SET Set INPUT_CONVEYOR_WAIT_UPSTREAM_TIMEOUT 16421 INPUT_CONVEYOR_WAIT_ UPSTREAM_TIMEOUTCLEAR Clear INPUT_CONVEYOR_WAIT_UPSTREAM_TIMEOUT 16430 OUTPUT_CONVEYOR_WAI T_DOWNSTREAM_TIMEO UT-SET Set OUTPUT_CONVEYOR_WAIT_DOWNSTREAM_TIMEOUT 16431 OUTPUT_CONVEYOR_WAI T_DOWNSTREAM_TIMEO UT-CLEAR Clear OUTPUT_CONVEYOR_WAIT_DOWNSTREAM_TIMEOUT 16440 CONVEYOR_SAFETY_COV ER_OPEN-SET Set CONVEYOR_SAFETY_COVER_OPEN 16441 CONVEYOR_SAFETY_COV ER_OPEN-CLEAR Clear CONVEYOR_SAFETY_COVER_OPEN 16450 PREHEAT_NOT_UP-SET Set PREHEAT_NOT_UP 16451 PREHEAT_NOT_UPCLEAR Clear PREHEAT_NOT_UP 16460 PREHEAT_NOT_DOWNSET Set PREHEAT_NOT_DOWN 16461 PREHEAT_NOT_DOWNCLEAR Clear PREHEAT_NOT_DOWN 16470 INPUT_CONVEYOR_NOT_ READY-SET Set INPUT_CONVEYOR_NOT_READY 16471 INPUT_CONVEYOR_NOT_ READY-CLEAR Clear INPUT_CONVEYOR_NOT_READY 16480 OUTPUT_CONVEYOR_NO T_READY-SET Set OUTPUT_CONVEYOR_NOT_READY 16481 OUTPUT_CONVEYOR_NO T_READY-CLEAR Clear OUTPUT_CONVEYOR_NOT_READY 16490 INPUT_CONVEYOR_COM M_TIMEOUT_2-SET Set INPUT_CONVEYOR_COMM_TIMEOUT_2 16491 INPUT_CONVEYOR_COM M_TIMEOUT_2-CLEAR Clear INPUT_CONVEYOR_COMM_TIMEOUT_2 16500 OUTPUT_CONVEYOR_CO MM_TIMEOUT_2-SET Set OUTPUT_CONVEYOR_COMM_TIMEOUT_2 16501 OUTPUT_CONVEYOR_CO MM_TIMEOUT_2-CLEAR Clear OUTPUT_CONVEYOR_COMM_TIMEOUT_2 (U2) Page - 258 - of 321 Sep 18, 2020 Rev 4.1 Kulicke & Soffa™ SECS/GEM Interface for K&S Ball Bonders Bonder software version x-xx-x-472-series IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Collection Events CEID Name Description EH_NSOP_SKIP_DEV_BY_ BOND_NEXT_WIRE_FAILE D-SET Alarm Set: EH_NSOP_SKIP_DEV_BY_ BOND_NEXT_WIRE_FAILE D-CLEAR Alarm Clear: 16520 EXT_2D_BCR_READ_FAILSET External 2D BCR read fail alarm set 16521 EXT_2D_BCR_READ_FAILCLEAR External 2D BCR read fail alarm clear 16530 REMOTE_PARMS_UPLOA D_FAIL-SET Set REMOTE_PARMS_UPLOAD_FAIL 16531 REMOTE_PARMS_UPLOA D_FAIL-CLEAR Clear REMOTE_PARMS_UPLOAD_FAIL 16540 REMOTE_PARMS_DOWNL OAD_FAIL-SET Set REMOTE_PARMS_DOWNLOAD_FAIL 16541 REMOTE_PARMS_DOWNL OAD_FAIL-CLEAR Clear REMOTE_PARMS_DOWNLOAD_FAIL 16550 OUT_SLOT_LF_DETECTE D-SET Alarm OUT_SLOT_LF_DETECTED set 16551 OUT_SLOT_LF_DETECTE D-CLEAR Alarm OUT_SLOT_LF_DETECTED cleared 16560 OMH_LF_RETAINER_NOT_ IN_POS-SET Alarm OMH_LF_RETAINER_NOT_IN_POS set 16561 OMH_LF_RETAINER_NOT_ IN_POS-CLEAR Alarm OMH_LF_RETAINER_NOT_IN_POS cleared 16570 PDT_PULLTST_OUT_OF_L IMIT -SET Set CEID for ALID PDT_PULLTST_OUT_OF_LIMIT 16571 PDT_PULLTST_OUT_OF_L IMIT -CLEAR Clear CEID for ALID PDT_PULLTST_OUT_OF_LIMIT 16580 OUT_SLOT_LF_DETECTE D_2-SET Alarm OUT_SLOT_LF_DETECTED_2 set 16581 OUT_SLOT_LF_DETECTE D_2-CLEAR Alarm OUT_SLOT_LF_DETECTED_2 cleared 16590 EH_BOFF_POS_INVALIDSET Alarm Set: EH_BOFF_POS_INVALIDCLEAR Alarm Clear: EH_MAG_SERVICE_POSISET Detect EH_MAG_SERVICE_POSI_NEED_RETURN (U2) 16510 16511 16591 16600 NSOP Skip Device by Bond Next Wire Failed NSOP Skip Device by Bond Next Wire Failed Bond Off Position Invalid Bond Off Position Invalid Page - 259 - of 321 Sep 18, 2020 Rev 4.1 Kulicke & Soffa™ SECS/GEM Interface for K&S Ball Bonders Bonder software version x-xx-x-472-series IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Collection Events CEID Name Description 16601 EH_MAG_SERVICE_POSICLEAR Clear EH_MAG_SERVICE_POSI_NEED_RETURN 16610 RPM_HEALTH_WARNINGSET Set RPM_HEALTH_WARNING 16611 RPM_HEALTH_WARNINGCLEAR Clear RPM_HEALTH_WARNING 16620 RPM_NO_COMMS-SET Set RPM_NO_COMMS 16621 RPM_NO_COMMS-CLEAR Clear RPM_NO_COMMS 16630 RPM_SUBSYSTEM_HEALT H_WARNING-SET Set RPM_SUBSYSTEM_HEALTH_WARNING 16631 RPM_SUBSYSTEM_HEALT H_WARNING-CLEAR Clear RPM_SUBSYSTEM_HEALTH_WARNING 16640 RPM_ANALYTICS_FAULTSET Set RPM_ANALYTICS_FAULT 16641 RPM_ANALYTICS_FAULTCLEAR Clear RPM_ANALYTICS_FAULT 16650 EH_Z_LINK_WARM_UP_AB ORT-SET Set CEID for ALID EH_Z_LINK_WARM_UP_ABORT 16651 EH_Z_LINK_WARM_UP_AB ORT-CLEAR Clear CEID for ALID EH_Z_LINK_WARM_UP_ABORT 16660 BH_CI_COLL_PRE_CONDI TION_ERR-SET Set BH_CI_COLL_PRE_CONDITION_ERR 16661 BH_CI_COLL_PRE_CONDI TION_ERR-CLEAR Clear BH_CI_COLL_PRE_CONDITION_ERR 16670 INPUT_LF_PICKUP_HOME _NOT_FOUND-SET VLF fork type input pickup home sensor not found - set 16671 INPUT_LF_PICKUP_HOME _NOT_FOUND -CLEAR VLF fork type input pickup home sensor not found - clear 16680 INPUT_LF_PUSHER_HOM E_NOT_FOUND-SET VLF fork type input pusher home sensor not found - set 16681 INPUT_LF_PUSHER_HOM E_NOT_FOUND-CLEAR VLF fork type input pusher home sensor not found - clear 16690 OUTPUT_LF_GRIPPER_H OME_NOT_FOUND-SET VLF fork type output gripper home sensor not found - set 16691 OUTPUT_LF_GRIPPER_H OME_NOT_FOUND-CLEAR VLF fork type output gripper home sensor not found - clear 16700 INPUT_MH_EMPTY_FORKSET VLF fork type on-loader has no fork - set 16701 INPUT_MH_EMPTY_FORKCLEAR VLF fork type on-loader has no fork - clear (U2) Page - 260 - of 321 Sep 18, 2020 Rev 4.1 Kulicke & Soffa™ SECS/GEM Interface for K&S Ball Bonders Bonder software version x-xx-x-472-series IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Collection Events CEID Name Description 16710 INPUT_LF_PICKUP_DETE CT_FAIL-SET VLF fork type input pickup fail to get lead frame - set 16711 INPUT_LF_PICKUP_DETE CT_FAIL-CLEAR VLF fork type input pickup fail to get lead frame - clear 16720 INPUT_LF_DROP_ACTION _FAIL-SET VLF fork type input pickup fail to drop lead frame on track - set 16721 INPUT_LF_DROP_ACTION _FAIL-CLEAR VLF fork type input pickup fail to drop lead frame on track - clear 16730 INPUT_LF_STANDBY_ACTI ON_FAIL-SET VLF fork type input pickup fail to go to standby position - set 16731 INPUT_LF_STANDBY_ACTI ON_FAIL-CLEAR VLF fork type input pickup fail to go to standby position - clear 16740 INPUT_LF_PUSH_ACTION _FAIL-SET VLF fork type input pusher fail to push lead frame in - set 16741 INPUT_LF_PUSH_ACTION _FAIL-CLEAR VLF fork type input pusher fail to push lead frame in - clear 16750 OUTPUT_MH_EMPTY_FOR K-SET VLF fork type off-loader has no fork - set 16751 OUTPUT_MH_EMPTY_FOR K-CLEAR VLF fork type off-loader has no fork - clear 16760 OUTPUT_LF_GRIP_ACTIO N_FAIL-SET VLF fork type output gripper action fail - set 16761 OUTPUT_LF_GRIP_ACTIO N_FAIL-CLEAR VLF fork type output gripper action fail - clear 16770 CI_SAFE_POS_SNS_DETE CT-SET SETCE for CI_SAFE_POS_SNS_DETECT 16771 CI_SAFE_POS_SNS_DETE CT-CLEAR CLEARCE for CI_SAFE_POS_SNS_DETECT 16780 ACC_ALIGNMENT_ERROR -SET Set ACC_ALIGNMENT_ERROR 16781 ACC_ALIGNMENT_ERROR -CLEAR Clear ACC_ALIGNMENT_ERROR 16790 ACC_ROBOT_ERROR-SET Set ACC_ROBOT_ERROR 16791 ACC_ROBOT_ERRORCLEAR Clear ACC_ROBOT_ERROR 16800 RPM_DATAVIZ_FAULTSET RPM_DATAVIZ_FAULT-SET 16801 RPM_DATAVIZ_FAULTCLEAR RPM_DATAVIZ_FAULT-CLEAR (U2) Page - 261 - of 321 Sep 18, 2020 Rev 4.1 Kulicke & Soffa™ SECS/GEM Interface for K&S Ball Bonders Bonder software version x-xx-x-472-series IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Collection Events CEID Name Description 16810 EH_PP_AUTO_CONV_FAIL -SET Set CEID for ALID EH_PP_AUTO_CONV_FAIL 16811 EH_PP_AUTO_CONV_FAIL -CLEAR Clear CEID for ALID EH_PP_AUTO_CONV_FAIL 16820 PREHEAT_VAC_NOT_ONSET Preheat vacuum not on alarm set 16821 PREHEAT_VAC_NOT_ONCLEAR Preheat vacuum not on alarm clear 16830 PREHEAT_VAC_NOT_OFFSET Preheat vacuum not off alarm set 16831 PREHEAT_VAC_NOT_OFFCLEAR Preheat vacuum not off alarm clear 16840 EH_IDLE_PROMPT_EJECT _LF_TIMEOUT-SET for EH EH_IDLE_PROMPT_EJECT_LF_TIMEOUT (Idle Mode ECO Prompt To Eject Leadframes time out) 16841 EH_IDLE_PROMPT_EJECT _LF_TIMEOUT-CLEAR for EH EH_IDLE_PROMPT_EJECT_LF_TIMEOUT (Idle Mode ECO Prompt To Eject Leadframes time out) 16850 EH_CD_SKIP_PROC_LIMIT _EXCEEDED-SET Alarm set: CD skipped processing - exceed limit 16851 EH_CD_SKIP_PROC_LIMIT _EXCEEDED-CLEAR Alarm clear: CD skipped processing - exceed limit 16870 INPUT_SMEMA_START_T RANSFER_TIMEOUT -SET Set input smema start transfer timeout error 16871 INPUT_SMEMA_START_T RANSFER_TIMEOUTCLEAR Clear input smema start transfer timeout error 16880 INPUT_SMEMA_END_TRA NSFER_TIMEOUT-SET Set input smema end transfer timeout error 16881 INPUT_SMEMA_END_TRA NSFER_TIMEOUT-CLEAR Clear input smema end transfer timeout error 16890 INPUT_SMEMA_INVALID_A CK_SIG_STATE-SET Set input smema invalid acknowledgement signal state error 16891 INPUT_SMEMA_INVALID_A CK_SIG_STATE-CLEAR Clear input smema invalid acknowledgement signal state error 16900 WIRE-INSP-WIRE-STOPERR-SET Alarm set for EH #2560 16901 WIRE-INSP-WIRE-STOPERR-CLEAR Alarm clear for EH #2560 16910 WIRE-INSP-UNIT-STOPERR-SET Alarm set for EH #2561 16911 WIRE-INSP-UNIT-STOPERR-CLEAR Alarm clear for EH #2561 (U2) Page - 262 - of 321 Sep 18, 2020 Rev 4.1 Kulicke & Soffa™ SECS/GEM Interface for K&S Ball Bonders Bonder software version x-xx-x-472-series IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Collection Events CEID Name Description 16920 WIRE-INSP-EXCEEDWARN-LIMIT-SET Alarm set for EH #2562 16921 WIRE-INSP-EXCEEDWARN-LIMIT-CLEAR Alarm clear for EH #2562 16930 WIRE-INSP-REALIGNFAILURE-SET Alarm set for EH #2563 16931 WIRE-INSP-REALIGNFAILURE-CLEAR Alarm clear for EH #2563 16940 EH_Z_LINK_WARM_UP_C OMPLETED-SET Set CEID for ALID EH_Z_LINK_WARM_UP_COMPLETED 16941 EH_Z_LINK_WARM_UP_C OMPLETED-CLEAR Clear CEID for ALID EH_Z_LINK_WARM_UP_COMPLETED 16950 WIRE-INSP-ID-NOTTAUGHT-SET Alarm set for WIRE-INSP-ID-NOT-TAUGHT 16951 WIRE-INSP-ID-NOTTAUGHT -CLEAR Alarm clear for WIRE-INSP-ID-NOT-TAUGHT 16990 EH_AUTO_LHM_LOOP_HE IGHT_INVALID-SET Auto loop height measurement too low or missing set 16991 EH_AUTO_LHM_LOOP_HE IGHT_INVALID-CLEAR Auto loop height measurement too low or missing clear (U2) Figure 60 – K&S Model Power Series Automatic Ball Bonder and K&S Model Gen-S Automatic Ball Bonder Shared Collection Events Page - 263 - of 321 Sep 18, 2020 Rev 4.1 Kulicke & Soffa™ SECS/GEM Interface for K&S Ball Bonders Bonder software version x-xx-x-472-series 6.5 K&S Model Power Series Automatic Ball Bonder and K&S Model Gen-S Automatic Ball Bonder Shared Alarms The Alarms and associated Alarm IDs (ALID) shared by K&S Model Power Series Automatic Ball Bonder and K&S Model Gen-S Automatic Ball Bonder are described in this section.All alarms listed in the alarm table have two associated collection events. One is sent when the alarm condition is detected, and the other is sent when the alarm condition is cleared. These events use the same names as their associated alarms, with ‘-SET’ or ‘-CLEAR’ appended to the event name, respectively. The CEID’s for the collection events associated with a given alarm can be derived by taking the last three digits of the ALID, multiplying by ten and adding 9000 to get the CEID of the collection event used to indicate that the alarm has been set. Add one to the set collection event CEID to get the CEID of the event used to indicate the alarm has been cleared. For example, for alarm 6027, the set collection event would be 9270, the clear event 9271. Page - 264 - of 321 Sep 18, 2020 Rev 4.1 Kulicke & Soffa™ SECS/GEM Interface for K&S Ball Bonders Bonder software version x-xx-x-472-series ALID (U2) 6001 6002 6003 6004 IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Alarms ALTX ALCD Description PDT-EFO-OPEN PDT-EFO-SHORT PDT-EFO-ERROR EFO-HAZARD 2 2 2 1 PDT-WIREFEEDERROR MANUAL-EFOOPEN MANUAL-EFOSHORT MANUAL-EFOERROR MANUAL-EFOHAZARD 2 PDT Error - EFO Open PDT Error - EFO Short PDT Error - EFO Error The software self diagnostics indicate error in EFO control code. Continued operation of EFO may be dangerous. DO NOT TOUCH THE EFO AREA PRIOR TO DISABLING HIGH VOLTAGE! PDT Wire Feed Error 2 Manual Error - EFO Open 2 Manual Error - EFO Short 2 Manual Error - EFO Error 2 5 6011 6012 AUTO-TEMP-OUTOF-LIMITS FATAL-ERROR OS-ERROR The software self diagnostics indicate error in EFO control code. Continued operation of EFO may be dangerous. DO NOT TOUCH THE EFO AREA PRIOR TO DISABLING HIGH VOLTAGE! Workholder Temperature Out of Set Limit 6013 INTERNAL-ERROR 2 6014 PROCESS-ERROR 6 6015 MHS_MOTOR_DRI VER_ERROR IND_DEVICE_OVE RHEATED IND_NO_CLAMP_ VACUUM IND_CARRIER_JA M MH_BAD_GRIPPE R_CHANGE MON-X-MOTOROVER-TEMP MON-YL-MOTOROVER-TEMP MON-YR-MOTOROVER-TEMP MON-Z-MOTOROVER-TEMP MON-T-MOTOROVER-TEMP 2 Fatal Error An Operating System error was detected which was compensated for. However, any further operation may compromise the machine. Secure the material and restart the machine as soon as possible. A software error occurred which was compensated for. However, any further operation may compromise the machine. Secure the material and restart as soon as possible. A process error was detected. Machine is designed to handle these types of errors. MHS motor driver error 2 Individual device overheated 2 Clamp vacuum not present. 2 Leadframe jammed during ejection. 5 2 Logic Error, Input magazine asked to change gripper size while mag gripped. X motor over temperature error. 2 Y motor over temperature error. 2 Y motor over temperature error. 2 Z motor over temperature error. 2 T motor over temperature error. 6005 6006 6007 6008 6009 6010 6016 6017 6018 6019 6022 6023 6024 6025 6026 5 2 Page - 265 - of 321 Sep 18, 2020 Rev 4.1 Kulicke & Soffa™ SECS/GEM Interface for K&S Ball Bonders Bonder software version x-xx-x-472-series ALID (U2) 6027 6028 6029 6030 6031 6032 6033 6034 6035 6036 6037 6038 6039 6040 6041 6042 6043 6044 6045 6046 6047 6048 6049 IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Alarms ALTX ALCD Description MON-RACKOVER-TEMP MON-PSUPPLYOVER-TEMP MON-WIREFEEDAIR-DOWN MON-SYSTEMAIR-DOWN MON-STEP1-BDFAULT MON-STEP2-BDFAULT TEMP_ZONE_OPE N_LOOP_ERROR POWER-FAILURE POWER-LOW POWEROVERTEMP SYSTEM-FAILURE PFAIL-DETECT 2 Card rack over temperature error. 2 Power supply over temperature error. 2 Wire-feed air is down error. 2 System air is down error. 2 Stepper board 1 any faults occur. 2 Stepper board 2 any faults occur. 2 Temperature Zone has open loop error. Zone was turned off. 5 2 2 Power Failure Detected. Power Low Detected. Power Supply Temperature Limit exceeded. 2 2 PFAILSHUTDOWNINCOMPLETE PFAILSHUTDOWNUNUSABLE PFAILRECOVERYFAILURE PFAIL-DIRTYPROGRAM 2 System failure detected. Power Failure Detected. Machine was ungracefully shut down prior to this power up. Incomplete Power Failure Shutdown. The last shutdown occurred during bonding and last wire was not successfully bonded. Corrupted Power Failure Data. The Power Failure Recovery Data is corrupted making the recovery impossible. PFAIL-BONDOFFFAILED PFAILSHUTDOWNPROCESS-ERROR PFAILSHUTDOWNFATAL-ERROR SERVO_FAULT 3 PARM_TYPE_INV ALID EH_FAINT6_CPU_ GENERIC_ERR PDTUNEXPECTEDNSOP 4 5 2 Power Failure Recovery Failure. An internal error occurred during Power Failure Recovery. 3 Dirty Program Detected. Program residing in memory prior to last shutdown was not saved to the disk. This makes Power Failure Recovery impossible. Bondoff Failure. The attempt to repair wire during Power Failure Recovery failed. Unrecoverable state. The last shutdown occurred while machine was in PROCESS ERROR state. Thus, Power Failure Recovery is impossible. Unrecoverable state. The last shutdown occurred while machine was in FATAL ERROR state. Thus, Power Failure Recovery is impossible. Servo error occurred. The machine entered the STANDBY mode. Please exit the STANDBY mode to resume the normal operation. Parameter type is invalid. 2 2 2 5 3 FATAL ERROR - CPU FAULT INTERRUPT. The machine stopped. Machine reboot is required. PDT Error - BITS Error NSOP Page - 266 - of 321 Sep 18, 2020 Rev 4.1 Kulicke & Soffa™ SECS/GEM Interface for K&S Ball Bonders Bonder software version x-xx-x-472-series ALID (U2) 6050 6051 6052 6053 6054 6055 6056 6057 6058 6059 6060 6061 6062 6063 6064 6065 6066 6067 6068 6069 6070 6071 IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Alarms ALTX ALCD Description PDTUNEXPECTEDNSOL PDTUNEXPECTEDSHTL AUTO-ALIGNFIND-FAIL AUTO-ALIGNLTOL-FAIL AUTO-VLL-FINDFAIL AUTO-VLL-WIDTHFAIL AUTO-XHAIRERROR AUTO-DRIFTERROR AUTO-TOOLUSAGE-LIMITEXCEEDED AUTOBONDHEADSAFETYVIOLATION AUTOBONDHEADTABLE-VIOLATION AUTO-AIR-OUTOF-LIMITS AUTO-TEMP-OUTOF-AD-RANGE AUTO-TEMP-OUTOF-AD-RANGECLXC MHS_WORKHOLD ER_NOT_EMPTY MHS_PUL_CARRI ER_ALREADY_PR ESENT FRL_WILL_REACH _LIMIT_INDEX PUL_HOME_NOT_ FOUND IND_HOME_NOT_ FOUND FRL_HOME_NOT_ FOUND RRL_HOME_NOT_ FOUND CI_HOME_NOT_F OUND 3 PDT Error - BITS Error NSOL 3 PDT Error - BITS Error SHTL 3 ALIGN status - inadequate eye points found 3 ALIGN status - line distance outside tolerance 3 VLL Error - Failed to Locate Lead 3 VLL Error - lead width out of tolerance 3 Auto X Hair Correction Error 3 3 Machine is unable to perform Automatic X Hair correction. Manual X Hair correction is needed Tool Usage Limit Exceeded 2 Tool couldn't be positioned with out possible collision with MHS 2 Tool couldn't be positioned with out exceeding table limits 3 Missing air supply 3 Temperature Sensor Out of A-D range. Check Thermocouple 3 5 Temperature Sensor for Zone 4 Out of A-D range. Check Bond Head Thermocouple. CLXC may not be used until this condition is cleared Workholder not empty. If material present, may damage material/machine Leadframe cannot be pulled in - one already present 5 Front rail will reach limit during device index 5 Puller's home not found 5 Indexer's home not found 5 Front rail's home not found 5 Rear rail's home not found 5 Clamp's home not found 5 Page - 267 - of 321 Sep 18, 2020 Rev 4.1 Kulicke & Soffa™ SECS/GEM Interface for K&S Ball Bonders Bonder software version x-xx-x-472-series ALID (U2) 6072 6073 6074 6075 6076 6077 6078 6079 6080 6081 6082 6083 6084 6085 6086 6087 6088 6089 6090 6091 6092 6093 6094 6095 IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Alarms ALTX ALCD Description HB_HOME_NOT_F OUND GRP_HOME_NOT _FOUND IND_CARRIER_ED GE_NOT_FOUND IND_DEVICE_NOT _FOUND IND_BOND_TEAC H_FAILURE PUL_CARRIER_N OT_PRESENT PUL_CARRIER_E DGE_NOT_FOUN D MHS_INIT_FAILUR E RAILS_LIMIT_DET ECTED FRL_LIMIT_DETE CTED RRL_LIMIT_DETE CTED Y_CORR_EXCEED S_LIMIT X_CORR_EXCEED S_UPDATE_LIMIT Y_CORR_EXCEED S_UPDATE_LIMIT RLS_INDEX_ERR OR MH_SLOT_SENSO R_BLOCKED_NON E_MAG MH_SLOT_SENSO R_BLOCKED_NON E_MAG_O MH_SLOT_SENSO R_BLOCKED MH_SLOT_SENSO R_BLOCKED_O MH_Y_SENSOR_F AILURE MH_Y_SENSOR_F AILURE_O MH_Z_SENSOR_F AILURE MH_Z_SENSOR_F AILURE_O RRL_WILL_REAC H_LIMIT_INDEX 5 Heat block's home not found 5 Indexer gripper's home not found 5 Lead frame's X registration edge not found 5 Device's eye point not found 5 Teach bonding position failure 5 Empty input magazine slot 5 Lead frame's X registration edge not found 5 MHS initialization failed 4 Rail limit sensor was blocked 4 Front rail limit sensor was blocked 4 Rear rail limit sensor was blocked 4 Y correction requested exceeds limit 4 X correction exceeds update limit 4 Y correction exceeds update limit 5 Rail index motion error 5 Cannot perform requested operation since Input magazine handler slot sensor is blocked 5 Cannot perform requested operation since Output magazine handler slot sensor is blocked 5 5 Cannot perform initialization operation since Input magazine handler slot sensor is blocked Cannot perform initialization operation since Output magazine handler slot sensor is blocked Input Y motor: motion error or home sensor timeout 5 Output Y motor: motion error or home sensor timeout 5 Input Z motor: motion error or home sensor timeout 5 Output Z motor: motion error or home sensor timeout 5 Rear rail will reach limit during device index 5 Page - 268 - of 321 Sep 18, 2020 Rev 4.1 Kulicke & Soffa™ SECS/GEM Interface for K&S Ball Bonders Bonder software version x-xx-x-472-series ALID (U2) 6096 6097 6098 6099 6100 6101 6102 6103 6104 6105 6106 6107 6108 6109 6110 6111 6112 6113 6115 6116 6117 6118 6119 6120 6121 IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Alarms ALTX ALCD Description MH_FAILED_STO RE_MAG MH_FAILED_STO RE_MAG_O MH_FAILED_GET_ MAG MH_FAILED_GET_ MAG_O MH_INPUT_TRAY_ EMPTY MH_INPUT_TRAY_ EMPTY_O MH_OUTPUT_TRA Y_FULL MH_OUTPUT_TRA Y_FULL_O MH_G_SENSOR_F AILURE MH_G_SENSOR_F AILURE_O MH_FAILED_OPE RATION_CHESS MH_FAILED_OPE RATION_CHESS_ O FRL_WILL_REACH _LIMIT_CORR RRL_WILL_REAC H_LIMIT_CORR FRL_LIMIT_REAC HED_INDEX MH_TRAY_NOT_D ETECTED MH_TRAY_NOT_D ETECTED_O MH_TRAY_DETEC T_SENSOR_FAILU RE MH_GRIP_SENSO RS_FAILED MH_GRIP_SENSO RS_FAILED_O MH_GRIP_ACTIVE _INVALID MH_GRIP_ACTIVE _INVALID_O MH_TOUCH_ACTI VE_INVALID MH_TOUCH_ACTI VE_INVALID_O MH_STATE_BAD_ SENSORS_GRIP 5 Failed to unload magazine in Input magazine handler 3 Failed to unload magazine in Output magazine handler 5 Input mag handler: Failed to load mag (calibration) 5 Output mag handler: Failed to load mag (calibration) 5 Input magazine handler, Load tray is empty 5 Output magazine handler, Load tray is empty 5 Input magazine handler, tray full sensor detected 5 Output magazine handler, tray full sensor detected 5 Input G motor: motion error or home sensor timeout Sensor in gripper not detected Output G motor: motion error or home sensor timeout Sensor in gripper not detected Input magazine handler, Cannot correct the situation, please chess to a safe location Output magazine handler, Cannot correct the situation, please chess to a safe location 5 5 5 3 Front rail reached limit during device index 3 Rear rail reached limit during device index 3 Front rail reached limit during device correction 5 Input magazine handler, tray not detected by sensor 5 Output magazine handler, tray not detected by sensor 5 Input magazine handler, unexpected tray sensor state 5 Input mag handler gripping sensor states not same 5 Output mag handler gripping sensor states not same 5 Input mag handler grip sensor blocked 5 Output mag handler grip sensor blocked 5 Input mag handler touch sensor blocked 5 Output mag handler touch sensor blocked 5 Input mag handler gripping sensors blocked Page - 269 - of 321 Sep 18, 2020 Rev 4.1 Kulicke & Soffa™ SECS/GEM Interface for K&S Ball Bonders Bonder software version x-xx-x-472-series ALID (U2) 6122 6123 6124 6125 6126 6127 6128 6129 6130 6131 6132 6133 6134 6135 6136 6137 6138 6139 6140 6141 6142 6143 6144 6145 6146 6147 IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Alarms ALTX ALCD Description MH_STATE_BAD_ SENSORS_GRIP_ O MH_INVALID_MAG _HEIGHT MH_INVALID_MAG _HEIGHT_O MH_STORE_SENS OR_ERROR MH_STORE_SENS OR_ERROR_O MH_TRAY_ERRO R_IN_LOAD MH_TRAY_ERRO R_IN_UNLOAD MH_TRAY_ERRO R_OUT_LOAD MH_TRAY_ERRO R_OUT_UNLOAD MHS_IND_AXIS_LI MIT_ERROR MHS_IND_JAM_R ELIEF_ERROR RRL_LIMIT_REAC HED_INDEX FRL_LIMIT_REAC HED_CORR RRL_LIMIT_REAC HED_CORR FRL_LIMIT_REAC HED_CYCLE RRL_LIMIT_REAC HED_CYCLE FRL_WILL_REACH _LIMIT_SETUP RRL_WILL_REAC H_LIMIT_SETUP PUL_NOT_OUT_O F_HOME IND_NOT_OUT_O F_HOME FRL_NOT_OUT_O F_HOME RRL_NOT_OUT_O F_HOME CI_NOT_OUT_OF_ HOME HB_NOT_OUT_OF _HOME GRP_NOT_OUT_O F_HOME IND_RECOVERY 5 Output mag handler gripping sensors blocked 5 Input mag handler: Failed to load mag (setup) 5 Output mag handler: Failed to load mag (setup) 5 5 Input mag handler store magazine error Tray Full or Tray Detect sensor active Output mag handler store magazine error Tray Full or Tray Detect sensor active A magazine was illegally place on the input mag's load tray or it was illegally taken off A magazine was illegally place on the Input Mag's unload tray or it was illegally taken off A magazine was illegally place on the Output Mag's load tray or it was illegally taken off A magazine was illegally place on the Output Mag's unload tray or it was illegally taken off Indexer Motion interrupted 5 Jam transducer decompression failure 4 Rear rail reached limit during device index 4 Front rail reached limit during device correction 4 Rear limit reached limit during device correction 4 Front rail reached limit during cycling 4 Rear rail reached limit during cycling 4 Front rail will reach limit during setup 4 Rear rail will reach limit during setup 5 Puller is not out of home 5 Indexer is not out of home 5 Front rail is not out of home 5 Rear rail is not out of home 5 Clamp is not out of home 5 Heat block is not out of home 5 Indexer gripper is not out of home 5 Index sequence aborted 5 5 5 5 5 Page - 270 - of 321 Sep 18, 2020 Rev 4.1 Kulicke & Soffa™ SECS/GEM Interface for K&S Ball Bonders Bonder software version x-xx-x-472-series ALID (U2) 6148 6149 6150 6151 6152 6153 6154 6155 6156 6157 6158 6159 6160 6161 6162 6163 6164 6165 6166 6167 6168 6169 IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Alarms ALTX ALCD Description IND_REMOVE_CR R CORR_IFR_WITH_ PREBOND_CRR RLS_CORRECT_E RROR WHL_HAS_DEVIC E_CLAMPED MH_INIT_CANNOT _STORE_MAGAZI NE MH_CHESS_TO_S AFE_LOCATION MH_DROP_MAGA ZINE MH_MUST_ALSO_ HOME_Y_MOTOR MH_MUST_ALSO_ HOME_Y_MOTOR _O MH_HOME_G_MU ST_HOME_Y_MOT OR MH_HOME_G_MU ST_HOME_Y_MOT OR_O MH_HOME_G_MU ST_HOME_Z_MOT OR MH_HOME_G_MU ST_HOME_Z_MOT OR_O MH_HOME_GRIPP ER_DROP_MAG MH_HOME_GRIPP ER_DROP_MAG_ O MH_INVALID_GRI P_STATE MH_INVALID_GRI P_STATE_O MH_INVALID_UNG RIP_STATE MH_INVALID_UNG RIP_STATE_O MH_TRAY_DETEC TED MH_TRAY_DETEC TED_O MH_GRIP_ACTIVE _INVALID_ABORT 5 Remove leadframe from the rails 5 Correction will interfere with pre-bond leadframe 5 Rail correction motion error 5 There is a clamped device present and operation will release this device Cannot unload magazine so cannot properly complete the initialization operation 5 5 Lost power fail data must chess to safe location 5 MH magazine will be dropped 5 Home operation on Input magazine handler will also Home the Y motor since damage to the trays could result otherwise Home operation on Output magazine handler will also home the Y motor since damage to the trays could result otherwise 5 5 Homing the gripper on the Input magazine handler while in the tray area could damage the trays 5 Homing the gripper on the Output magazine handler while in the tray area could damage the trays 5 Homing the gripper motor on the Input magazine handler may damage the handler so must first home the Z motor 5 Homing the gripper motor on the Output magazine handler may damage the handler so must first home the Z motor. 5 Homing the gripper on the Input magazine handler will drop the magazine Homing the gripper on the Output magazine handler will drop the magazine 5 5 5 5 5 5 5 5 Input magazine handler state says gripped yet touch and grip sensor are not both active Output magazine handler state says gripped yet touch and grip sensor are not both active Input magazine handler state says ungripped yet touch and/or grip sensor are active Output magazine handler state says ungripped yet touch and/or grip sensor are active Input magazine handler, tray detect sensor active at invalid location, Invalid sensor condition Output magazine handler, tray detect sensor active at invalid location, Invalid sensor condition Input mag handler grip sensor blocked Page - 271 - of 321 Sep 18, 2020 Rev 4.1 Kulicke & Soffa™ SECS/GEM Interface for K&S Ball Bonders Bonder software version x-xx-x-472-series ALID (U2) 6170 6171 6172 6173 6174 6175 6176 6179 6180 6181 6182 6183 6184 6185 6186 6187 6188 6189 6190 6191 6192 IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Alarms ALTX ALCD Description MH_GRIP_ACTIVE _INVALID_ABORT _O MH_TOUCH_ACTI VE_INVALID_ABO RT MH_TOUCH_ACTI VE_INVALID_ABO RT_O MH_STATE_BAD_ SENSORS_GRIP_ ABORT MH_STATE_BAD_ SENSORS_GRIP_ ABORT_O MH_OP_SUSPEN D MH_OP_SUSPEN D_O MH_TEACH_TOO_ MUCH_ROTATION MH_TEACH_OPER ATION_FAILED MH_CAL_SLOT_O PERATION_FAILE D MH_CAL_TRAY_O PERATION_FAILE D IND_THETA_EXTE ND_FAILURE MHS_JDC_CMD_F AILURE MHS_JDC_DIAG_F AILURE MHS_JDC_INIT_F AILURE PUL_Y_REGISTRA TION_FAILURE PUL_CARRIER_MI SSING PUL_Y_REGISTRA TION_ACTIVE MHS_INDEXER_C ALIBRATION_UNS UCCESSFUL MHS_CLAMP_CAL IBRATION_UNSUC CESSFUL MHS_RAILS_CALI BRATION_UNSUC CESSFUL 5 Output mag handler grip sensor blocked 5 Input mag handler touch sensor blocked 5 Output mag handler touch sensor blocked 5 Input magazine handler state reports ungripped, and sensors report a magazine is gripped 5 Output magazine handler state reports ungripped, and sensors report a magazine is gripped 5 Input mag handler: Operation Suspended 5 Output mag handler: Operation Suspended 5 Too much rotation found when teaching mag. 5 Teach operation failed 5 Calibrate slot operation failed 5 Calibrate tray operation failed 5 Theta bar not extended due to indexer's position 5 Jam Detect command failed 5 Jam Detect diagnostic failed - do calibration 5 Work holder JDC cross load failed 5 Lead frame's Y registration edge not found 5 leadframe is not present on the work holder 5 Y registration sensor is already blocked 5 indexer calibration terminated 5 clamp calibration terminated 5 rails calibration terminated Page - 272 - of 321 Sep 18, 2020 Rev 4.1 Kulicke & Soffa™ SECS/GEM Interface for K&S Ball Bonders Bonder software version x-xx-x-472-series ALID (U2) 6193 6194 6195 6196 6197 6198 6199 6200 6201 6202 6204 6205 6206 6207 6208 6209 6210 6211 6212 6213 6214 IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Alarms ALTX ALCD Description MHS_X_SENSOR_ CALIBRATION_UN SUCCESSFUL MHS_CAL_TUCKE R_EJECT_OPERA TION_FAILED MHS_JAM_CALIB RATION_UNSUCC ESSFUL MHS_IN_BCR_FAI L MHS_OUT_BCR_F AIL AUTO_INVALID_M AG PBI-UNIT-STOPERR AUTO-LEAD-BPCERR AUTO-USGIMPEDANCE-CALFAIL AUTO-USGIMPEDANCE-OUTLIMIT TEMPERATURE_A UTO_TUNE_FAIL AUTO-CU-COVERGAS-PRESSUREOUT-LIMIT TABLE_LIMITS_U NACCEPTABLE AUTO-VLL-FMDETECTED AUTOOVERLAPPEDDIES AUTO-ALIGNREFDRIFT-FAIL AUTO_BOND_CO UNT_REACHING_ LIMIT AUTO_BOND_CO UNT_REACHING_ LIMIT_NOWAIT PDTBONDHEIGHTERROR ZTC-OUT-OFLIMITS PBI-WIRE-STOPERR 5 Work holder X sensor calibration terminated 5 Indexer tucker eject calibration terminated 5 jam detect calibration terminated 4 MHS in BCR Fail 4 MHS out BCR Fail 5 Auto Invalid Mag 2 Out of tolerance detected during Post Bond Inspection 2 4 A bond proximity check failed due to two or more leads were found to be too close. Auto USG impedance calibration failed. 3 USG impedance is out of limit. 5 Auto tuning of the heat block temperature failed 2 Nitrogen gas flow out of tolerance 6 X or Y table limits are unacceptable 3 Auto VLL foreign material detected. 3 Auto Overlapped Dies 3 Auto Algin Redrift Fail 3 Auto Bond Count Reach Limit 3 Auto Bond Count Reaching Limit NO Wait 3 Bond Height Error 5 Out of limits in zone temperature control. 2 Out of tolerance detected during Post Bond Inspection by wire. Page - 273 - of 321 Sep 18, 2020 Rev 4.1 Kulicke & Soffa™ SECS/GEM Interface for K&S Ball Bonders Bonder software version x-xx-x-472-series ALID (U2) 6215 6216 6217 6218 6219 6220 6221 6222 6223 6224 6225 6226 6227 6228 6229 6230 6231 6232 6233 6234 6235 6236 6237 6238 6239 IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Alarms ALTX ALCD Description CAP_CLEAN_TAP E_USAGE_EXCEE D_LIMIT EH-PDT-SMBALL PDTUNEXPECTEDNSOP-TOL PBI-REALIGNFAILURE CAP_CLEANING_L IMIT_EXCEEDED BONDSITE_CHKS UM_FAIL REF_SYS_XHAIR_ OFFSET_FAIL MH_WAIT_GET_M AG MH_WAIT_GET_M AG_O STRIP_ID_NOT_F OUND MH_WT_HOST_R ETRY_XCEED MH_WT_HOST_R ETRY_XCEED_O EH_SUB_VALIDAT ION_TIMEOUT MHS_IN_BCR_REJ ECT_ERROR MHS_OUT_BCR_R EJECT_ERROR EH_SUB_VALIDAT ION_REJECTED EH_EVENT_COUN T_THRESHOLD_E XCEEDED AUTO_USG_LOCK _FREQ_DRIFT EH_EVENT_COUN T_STOP_AUTO PDT-MOTIONTIMEOUT PDT-AWAITTIMEOUT PDT-CALLBACKREGISTRATION WARNING_EFO_N OT_HAZARD PDT-EFOINVALID-DATA EH-PDT-BUMPLIFT 6 Cap Clean Tape Usage Exceed Limit 2 3 PDT Error Small Ball Detected PDT Unexpected NSOP Top of Loop 2 PBI Realign Failure 3 Cap Cleaning Limit Exceeded 3 Bond Site check sum error 3 Ref Sys Xhair Offset Fail 3 Input MH Wait Get Mag 3 MH Wait Get Output Magazine 4 Strip ID Not Found 4 Input magazine validation timeout 4 Output magazine validation timeout 4 Substrate ID validation timeout 4 Input magazine is rejected by host 4 Output magazine is rejected by host 4 Substrate is rejected by host 7 Event Count Threshold Exceeded 4 USG Lock Frequency Drift 6 EH Event Count Stop Auto 5 PDT Motion Time out 5 PDT Await Time out 5 PDT Callback Registration 6 Warning EFO Not Hazard 4 PDT EFO Invalid Data 4 EH PDT Bump Lift Page - 274 - of 321 Sep 18, 2020 Rev 4.1 Kulicke & Soffa™ SECS/GEM Interface for K&S Ball Bonders Bonder software version x-xx-x-472-series ALID (U2) 6240 6241 6242 6243 6244 6245 6246 6247 6248 6249 6250 6251 6252 6253 6254 6255 6256 6257 6258 6259 6260 6261 6262 6263 6264 IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Alarms ALTX ALCD Description EFO-BOX-COMERROR EFO-RESOURCENOT-AVAILABLE PDT-NO-TIMERS PDT-NO-FSDETECT PDT-BITS-CALERROR PDT-DIE-MISSING PDTUNEXPECTEDLGTL PDTUNEXPECTEDNSOP-BY-PRS MANUALUNEXPECTEDNSOP MANUALUNEXPECTEDNSOL MANUALUNEXPECTEDSHTL MANUALWIREFEEDERROR MANUAL-EFOINVALID-DATA EFO-CLEAN MANUALUNEXPECTEDLGTL CAP-UNCLOG EH_AUTO_RECV_ REPLACE_BOFF_ PLATE AUTO-USG-LOCKDRIFT AUTO-EMS-LOW AUTO-ALIGNFATAL AUTO-ALIGNMOT-FAIL AUTO-ALIGN-PRSFAIL AUTO-ALIGN-VLLFAIL AUTO-UPDATEAWAIT-TIMEOUT AUTO-BAD-START 6 EFO Box Com Error 4 EFO Resource not Available 4 3 PDT NO Timers PDT NO FS Detect 3 PDT BITS Cal Error 6 6 PDT DIE Missing PDT Unexpected LGTL 6 Equipment Status Warning 6 Manual Unexcepted NSOP 6 Manual Unexcepted NSOL 6 Manual Unexcepted SHTL 6 Manual Wirefeed Error 6 Manual EFO Invalid Data 7 6 EFO Clean Manual Unexcepted LGTL 6 7 Cap UNCLOG EH Auto Recive Replace BOFF Plate 6 Auto USG Lock Drift 6 6 Auto EMS Low Auto Align Fatal 6 Auto Align MOT Failure 6 Auto Align PRS Failure 6 Auto Align VLL Failure 5 Auto Update Await Time Out 6 Auto Bad Start Page - 275 - of 321 Sep 18, 2020 Rev 4.1 Kulicke & Soffa™ SECS/GEM Interface for K&S Ball Bonders Bonder software version x-xx-x-472-series ALID (U2) 6265 6266 6267 6268 6269 6270 6271 6272 6273 6274 6275 6276 6277 6278 6279 6280 6281 6282 6283 6284 IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Alarms ALTX ALCD Description AUTOREJECTEYESKIPPARMSEXCEEDED AUTO-ZPROBESKIPPARMSEXCEEDED AUTO-LARGEDRIFT-ERROR FAILEDCAPILLARY-FIND MLO-EXCESSCHG-STOP BOFF-AREA-FULL AUTO-NEARINGTOOL-USAGELIMIT AUTOBONDHEADTABLEVIOLATIONNOWAIT AUTO-CONF-BPCERR AUTO-BITS-CFGXMATCH-SWDCHWAC AUTO-BITS-CFGXMATCH-SWACHWDC AUTO-PRE-BONDCHECK MC_IDLE_TOO_L ONG AUTO-WIREUSAGETHRESHOLDEXCEEDED AUTO-TOOLUSAGE-LIMITEXCEEDEDNOWAIT AUTO-MHSCLAMP-OPEN ZTC-AD-RANGEERROR AUTO-TEMP-OUTOF-RANGEOPTICS ZPROTECT-HIALARM ZPROTECT-OPENSENSOR 7 Auto Reject Eye Skip Parameters Exceeded 7 Auto ZPROBE Skip Parameters Exceeded 6 Auto Large Drift Error 6 Failed Capillary Find 7 MLO Excess CHG Stop 7 7 BOFF Area Full Auto Nearing Tool Usage Limit 7 Auto Bondhead Table Violation No Wait 4 Auto Configure BPC Error 4 Auto BITS Configure XMatch SWDC HWAC 4 Auto BITS Configure XMatch SWAC HWDC 7 Auto Prepare Bond Check 7 Machine Idle Too Long 7 Auto Wire Usage Threshold Exceeded 7 Auto Tool Usage Limit Exceeded No Wait 6 Auto MHS Clamp Open 5 ZTC AD Range Error 6 Auto Temp Out Of Range Optics 6 ZPROTECT HI Alarm 6 ZPROTECT Open Sensor Page - 276 - of 321 Sep 18, 2020 Rev 4.1 Kulicke & Soffa™ SECS/GEM Interface for K&S Ball Bonders Bonder software version x-xx-x-472-series ALID (U2) 6285 6286 6287 6288 6289 6290 6291 6292 6293 6294 6295 6296 6297 6298 6299 6300 6301 6302 6303 6304 6305 6306 6307 6308 6309 6310 IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Alarms ALTX ALCD Description AUTO-ALIGN-PADFAIL AUTO-TEMPCTRL-COMM-FAIL OPERATORERROR AUTO-MATROX-EDRIVE-FULL AUTO-EFO-LIMITEXCEEDED AUTO-EFOSTART-CLEAN AUTO_EFOPM_LI MIT_EXCEEDED TEST-ERROR MHS_UNDEFINED _CMD MHS_DISABLED_ ACTIVE_CMD MHS_UNAVAILAB LE_CMD_RESOUR CES MHS_LOGIC_ERR OR MHS_ALREADY_A CTIVE_CMD MHS_MSG_QUEU E_OVERFLOW MHS_DYNAMIC_L OAD_ERROR MHS_CONFIRM_C MD_RESOURCES MHS_LOGIC_ERR OR_NO_BLOCK PUL_CARRIER_AL READY_PRESENT MH_LOGIC_ERRO R MH_SETUP_ERRO R MH_CREATE_ERR OR MH_SEND_ERRO R MH_RX_ERROR MH_CHUTE_EMPT Y MH_CHUTE_EMPT Y_O MH_BAD_GRIPPE R_SIZE 6 Auto Align Pad failure 6 Auto Temo CTRL COMM Failure 6 Operate Error 5 Auto matrox E Drive Full 6 Auto EFO Limit Exceeded 7 Auto EFO Start Clean 6 Auto EFOPM Limit exceeded 3 3 Test Error MHS Undifined Command 3 MHS Disabled Active Command 3 MHS Unavailable Command Resources 3 MHS Logic Error 3 MHS Already Active Command 3 MHS Message Queue Overflow 3 MHS Dynamic Load Error 3 MHS Confirm Command Resources 3 MHS Logic Error No Block 7 PUL Carrier Already Present 3 MH Logic Error 3 MH Setup Error 3 MH Create Error 3 MH Send Error 3 7 MH RX Error MH Chute Empty 7 MH Chute Empty O 6 MH Bad Gripper Size Page - 277 - of 321 Sep 18, 2020 Rev 4.1 Kulicke & Soffa™ SECS/GEM Interface for K&S Ball Bonders Bonder software version x-xx-x-472-series ALID (U2) 6311 6312 6313 6314 6315 6316 6317 6318 6319 6320 6321 6322 6323 6324 6325 6326 6327 6328 6329 6330 6331 6332 6333 6334 6335 6336 IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Alarms ALTX ALCD Description MH_BAD_GRIPPE R_SIZE_O MH_BAD_GRIPPE R_CHANGE_O MH_TRAY_DETEC T_SENSOR_FAILU RE_O MH_MAG_IFR MH_MAG_IFR_O MH_PUSHER_NO T_RETRACT MH_PUSHER_NO T_RETRACT_0 MH_PUSHER_NO T_OUT MH_PUSHER_NO T_OUT_0 MH_MAG_IN_LOA D_NEW MH_MAG_OUT_L OAD_NEW MH_STANDBY_MA G_NOT_READY MH_STANDBY_MA G_NOT_READY_O MH_TRAY_FULL_ DETECT MH_TRAY_FULL_ DETECT_O MH_INVALID_SEN SOR MH_TEACH_OPER ATION_WORKED WHL_UNDEFINED _CRR_LOCK_STS WHL_UNDEFINED _INDEX_TYPE WHL_UNDEFINED _INDEX_STS WHL_UNDEFINED _CORR_STS WHL_UNDEFINED _INDEX_CYCLE WHL_UNDEFINED _INDEXER_STATE WHL_UNDEFINED _PULLER_STATE WHL_CANNOT_C REATE_SEMAPHO RE WHL_CANNOT_O PEN_CHANNEL 6 MH Bad Gripper Size O 6 MH Bad Gripper Change O 6 MH Tray Detect Sensor Failure O 6 6 6 MH Magazine IFR MH Magazine IFR O MH Pusher Not Retract 6 MH Pusher Not Retract O 6 MH Pusher Not Out 6 MH Pusher Not Out O 6 MH Magazine IN Load New 6 MH Magazine Out Load New 7 MH STANDBY Mag Not Ready 7 MH STANDBY Mag Not Ready O 6 MH Tray Full Detect 6 MH Tray Full Detect O 6 MH Invalid Sensor 7 MH Teach Operation Worked 7 WHL Undefined CRR Lock STS 4 WHL Undefined Index Type 4 WHL Undefined Index STS 4 WHL Undefined CORR STS 4 WHL Undefined Index Cycle 4 WHL Undefined Indexer State 4 WHL Undefined Puller State 3 WHL Cannot Create Semaphore 3 WHL cannot Open Channel Page - 278 - of 321 Sep 18, 2020 Rev 4.1 Kulicke & Soffa™ SECS/GEM Interface for K&S Ball Bonders Bonder software version x-xx-x-472-series ALID (U2) 6337 6338 6339 6340 6341 6342 6343 6344 6345 6346 6347 6348 6349 6350 6351 6352 6353 6354 6355 6356 6357 6358 6359 6360 IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Alarms ALTX ALCD Description WHL_UNDEFINED _PULL_TYPE WHL_WANTS_BO NDHEAD_MOVED WHL_WANTS_BO NDHEAD_POSITIO NED MHS_CMD_TBL_S IZE_ERROR MHS_JDC_CMD_T IMEOUT PUSHER_KIT_JAM PUSHER_KIT_SEN SOR_FAILURE SENSOR_MON_U NSAFE SENSOR_MON_U NSAFE_WHEN_B ONDING MH_FAILED_GRIP _MAG_O PULLER_GRIPPE R_SENSOR_FAILU RE RAILS_TARGET_P OS_CLIPPED MHS_NEED_CAL_ FOR_CIWIDTHCH K_NO_DONE EH_CAPILLARY_D ETECTION_ERRO R EH_FAST_PACKA GE_ALIGN_FAIL IND_LOAD_SENS OR_UNSAFE RWH_INDEX_FAIL URE MHS_PARAMETE R_ERROR RWH_IM_CMD_FA ILURE RWH_IV_CMD_FAI LURE RWH_CB_CMD_F AILURE INDEX_GRP_SEN SOR_FAILURE EJECT_GRP_SEN SOR_FAILURE PUL_CARRIER_W RONG_ORIENTATI ON 4 WHL Undefined Pull Type 6 WHL Wants Bondhead Moved 6 WHL Wants Bondhead Positioned 3 MHS CMD TBL Size Error 3 MHS JDC CMD Timeout 6 6 Pusher Kit JAM Pusher Kit Sensor Failure 6 Sensor MON Unsafe 6 Sensor MON unsafe When Bonding 6 MH Failed Grip Mag O 6 Puller Gripper Sensor Failure 6 Rails Target Pos Clipped 6 MHS Need Cal for CIWIDTHCHK No Done 6 EH Capillary Detection Error 3 Fast package alignment error report 6 IND Load Sensor Unsafe 6 RWH Index Failure 4 MHS Parameter Error 3 RWH JM CMD Failure 3 RWH IV CMD Failure 3 RWH CB CMD Failure 6 Index GRP Sensor Failure 6 Eject GRP Sensor Failure 4 PUL Carrier Wrong Orientation Page - 279 - of 321 Sep 18, 2020 Rev 4.1 Kulicke & Soffa™ SECS/GEM Interface for K&S Ball Bonders Bonder software version x-xx-x-472-series ALID (U2) 6361 6362 6363 6364 6365 6366 6367 6368 6369 6370 6371 6372 6373 6374 6375 6376 6377 6378 6379 6380 6381 6382 6383 6384 6385 6386 IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Alarms ALTX ALCD Description PUL_CARRIER_O RIENTATION_EDG E_NOT_FOUND MHS_WHL_VERIFI CATION_UNSUCC ESSFUL INDEX_THETA_BA R_SENSOR_FAILU RE EJECT_THETA_BA R_SENSOR_FAILU RE MHS_GRIP_POINT _ERROR MHS_GP_ERROR _INDEX_ABORT LOAD_FAILED LOAD_INFO LOAD_INTERNAL_ ERROR LOADER_BUSY AUTO_PARAM_LO AD_FAILED MISCT_PARAM_L OAD_FAILED LEADT_PARAM_L OAD_FAILED PADT_PARAM_LO AD_FAILED INV_AUTO_PRM_ DATA_PTR AUTO_PRM_RES_ NOT_REL AUTO_PRM_RES_ NOT_AVL INV_TCH_PRM_D ATA_PTR MISCT_PRM_RES _NOT_REL MISCT_PRM_RES _NOT_AVL LEADT_PRM_RES _NOT_REL LEADT_PRM_RES _NOT_AVL PADT_PRM_RES_ NOT_REL PADT_PRM_RES_ NOT_AVL RESTORE_ERRO R BACKUP_ERROR 6 PUL Carrier Orientation Edge Not Found 6 MHS WHL Verification Unsuccessful 6 Index Theta Bar Sensor Failure 6 Eject Theta Bar Sensor Failure 6 MHS Grip Point Error 6 MHS GP Error Index Abort 6 7 6 Load failed Load Info Load Internal Error 6 4 Loader Busy Auto Parameter Load Failure 4 MISCT Param Load Failure 4 LEADT Param Load Failure 4 PADT Param Load Failure 4 INV Auto PRM Data PTR 4 Auto PRM RES Not REL 4 Auto PRM RES Not AVL 4 INV TCH PRM DATA PTR 4 MISCT PRM RES Not REL 4 MISCT PRM RES Not AVL 4 LEADT PRM RES Not REL 4 LEADT PRM RES Not AVL 4 PADT PRM RES Not REL 4 PADT PRM RES Not AVL 6 Restore Error 6 Backup Error Page - 280 - of 321 Sep 18, 2020 Rev 4.1 Kulicke & Soffa™ SECS/GEM Interface for K&S Ball Bonders Bonder software version x-xx-x-472-series ALID (U2) 6387 6388 6389 6390 6391 6392 6393 6394 6395 6396 6397 6398 6399 6400 6401 6402 6403 6404 6405 6406 6407 6408 6409 IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Alarms ALTX ALCD Description SELECT_ERROR MEMORY_ERROR FILE_ERROR CLEANUP_ERROR BACKUP_LIST_FIL E_INVALID PP_HEAP_ALLOC _FAILED PP_HEAP_CREAT E_FAILED PP_HEAP_SIZE_I NVALID MON-Y-MOTOROVER-TEMP MON-MOTORWARNING MON-UPSRUNNING MON-SENSORBUS-ERROR MON-UPS-BADBATTERY EH_MON_IDLE_CL AMP_OPEN_TIME OUT EH_GRIPPER_SO LENOID_OVER_T EMP_FAIL EH_STANDBY_SE ND_MHS_COMMA ND EH_STANDBY_ER ROR POWER-FAILURE-REBOOTMACHINE MOMENTARYPOWER-FAILURE POWER-LOW-REBOOTMACHINE MOMENTARYPOWER-LOW POWEROVERTEMP-REBOOTMACHINE MOMENTARYPOWEROVERTEMP 6 6 6 6 6 Select Error Memory Error File Error Clean Up Error Backup List File Invalid 6 PP Heap Alloc Failure 6 PP Heap Alloc Failure 6 PP Heap Size Invalid 6 MON Y Motor Over Temp 6 MON Motor Warning 6 MON UPS Running 6 MON Sensor Bus Error 6 MON UPS Bad Battery 7 EH MON Idle Clamp Open Time Out 6 EH Gripper Solenoid Over Temp Failure 6 EH Standby Send MHS Command 6 EH Standby Error 7 Power Failure Reboot Machine 6 Momentary Power Failure 6 Power Low Reboot Machine 6 Momentary Power Low 6 Power Overtemp Reboot Machine 6 Momentary Power Overtemp Page - 281 - of 321 Sep 18, 2020 Rev 4.1 Kulicke & Soffa™ SECS/GEM Interface for K&S Ball Bonders Bonder software version x-xx-x-472-series ALID (U2) 6410 6411 6412 6413 6414 6415 6416 6417 6418 6419 6420 6421 6422 6423 6424 6425 6426 6427 6428 6429 IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Alarms ALTX ALCD Description SYSTEMFAILURE-REBOOTMACHINE MOMENTARYSYSTEM-FAILURE ZCONTACT_FAILU RE ZPOSITION_ERRO R ZSEEK_RECOVERY _ERROR CPU2_Z_NEG_LIM IT_UPDATE_ERR OR XPOSITION_ERRO R YPOSITION_ERRO R EH_Z_LIMIT_FIND _ERROR EH_BFC_MOTION _ERROR EH_BFC_NON_MO TION_ERROR EH_ZMAP_MOTIO N_ERROR EH_BITS_AGC_CA L_NOT_DONE EH_FS_BONDOFF _VERIFY_FAIL EH_WFEED_COM PORT_OPER_ERR OR EH_WFEED_COM MUNICATION_ER ROR TEMPERATURE_C OMMUNICATION_ ERROR EH_TEMP_INVALI D_PARAMS EH_TEMP_RESOU RCE_ACQUIRE_E RROR EH_TEMP_INVALI D_SYS_R_SELEC TOR 6 System Failure Reboot Machine 6 Momentary System Failure 6 Z Contact Failure 6 Z Position Error 3 Z Seek Recovery Error 3 CPU2 Z NEG Limit Update Error 2 X Position Error 2 Y Position Error 6 EH Z Limit Find Error 2 EH BFC Motion Error 2 EH BFC NON Motion Error 2 EH ZMAP Motion Error 3 EH BITS AGC CAL Not Done 6 EH FS Bondoff Verify Failure 3 EH WFEED Comport Oper Error 6 EH WFEED Communication Error 6 Temperature Communication Error 4 EH Temp Invalid Parameters 3 EH Temp Resource Acquire Error 4 EH Temp Invalid SYS R Selector Page - 282 - of 321 Sep 18, 2020 Rev 4.1 Kulicke & Soffa™ SECS/GEM Interface for K&S Ball Bonders Bonder software version x-xx-x-472-series ALID (U2) 6430 6431 6432 6433 6434 6435 6436 6437 6438 6439 6440 6441 6442 6443 6444 6445 6446 6447 6448 6449 6450 6451 IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Alarms ALTX ALCD Description EH_TEMP_INVALI D_SYS_G_SELEC TOR EH_TEMP_INVALI D_ZONE_R_SELE CTOR EH_TEMP_INVALI D_ZONE_EM_SEL ECTOR EH_TEMP_PID_RE SET_VALUE_ERR OR EH_TEMP_OFFSE T_VALUE_ERROR EH_TEMP_ZONE_ EM_PARAM_ERR OR EH_TEMP_SERIAL _WRITE_ERROR EH_TEMP_SERIAL _READ_ERROR EH_TEMP_ERROR _MSG_REPLY EH_TEMP_READ_ NOT_READY EH_TEMP_WRITE _NOT_READY EH_TEMP_IO_SEL ECT_ERROR EH_TEMP_WRITE _PROTECTED_PA RM EH_TEMP_UNKNO WN_ERROR EH_TEMP_CHANG ERATE_ERROR EH_IDIAG_SYNCH _ERROR EH_IDIAG_ASYNC H_ERROR EH_IDIAG_TEMP_ ZONE_FAULT EH_IDIAG_BITS_M ODE_HW_SW_MIS MATCH EH_IDIAG_BITS_C ROSSLOAD_ERR OR EH_BITS_FULL_A GC_FAILED EH_BITS_WF_DU MP_FAILED 4 EH Temp Invalid SYS G Selector 4 EH Temp Invalid ZONE R Selector 4 EH Temp Invalid ZONE EM Selector 6 EH Temp PID Reset Value Error 4 EH Temp Offset Value Error 4 EH Temp ZONE EM Param Error 6 EH Temp Serial Write Error 6 EH Temp Serial Read Error 3 EH Temp Error MSG Reply 3 EH Temp Read Not Ready 3 EH Temp Write Not Ready 6 EH Temp IO Select Error 4 EH Temp Write Protected Parm 5 EH Temp Unknown Error 2 EH Temp Changerate Error 3 EH Idiag Synch Error 3 5 EH Idiag Asynch Error EH Idiag Temp Zone Fault EH Idiag Temp Zone Fault 6 EH Idiag BITS Mode HW SW Mismatch 3 EH Idiag BITS Crossload Error 3 EH BITS Full AGC Failed 7 EH BITS WF DUMP Failed Page - 283 - of 321 Sep 18, 2020 Rev 4.1 Kulicke & Soffa™ SECS/GEM Interface for K&S Ball Bonders Bonder software version x-xx-x-472-series ALID (U2) 6452 6453 6454 6455 6456 6457 6458 6459 6460 6461 6462 6463 6464 6465 6466 6467 6468 6469 6470 6471 6472 6473 6474 6475 6476 6477 6478 IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Alarms ALTX ALCD Description EH_BITS_WF_LO G_FAILED EH_IDIAG_EEPRO M_ERROR EH_IDIAG_INVALI D_TABLE_CONFIG TAR_ERROR TAR_WARNING FLOPPY_WRITE_ PROTECTED FLOPPY_INSERT_ ERROR DEVICE_READY_ ERROR DISK_FULL_ERRO R INSERT_NEXT_DI SK CALIBRATION_DA TA_ERROR INVALID MISSING_MARKE RS CRC_OR_TIME_IN VALID CRC_STRING_LE NGTH_INVALID TIME_STRING_LE NGTH_INVALID EH_BONDER_CO NFIG_ERROR EH_FAINT6_CPU_ SPURIOUS_INT EH_PCI_BRIDGE_ FAILURE EH_SERDES_BUS _ERROR EH_CHESS_IN_US E EH_ILLEGAL_CHE SS_RELEASE EH_ILLEGAL_CHE SS_NAME NVR_MAC_ADDR_ CORRUPTION NVR_PROT_MEM_ CORRUPTION NVR_GENERAL_M EM_CORRUPTION EH-BOOT-PARMSAVE-ERR 7 EH BITS WF Log Failed 3 EH Idiag Eeprom Error 4 EH Idiag Invalid Table Configure 8 8 3 Tar Error Tar Warning Floppy Write Protected 3 Floppy Insert Error 6 Device Ready Error 6 Disk Full Error 7 Insert Next Disk 3 Calibration Data Error 6 6 Invalid Missing Markers 4 CRC Or Time Invalid 4 CRC String Length Invalid 4 Time String Length Invalid 4 EH Bonder Config Error 5 EH Faint6 CPU Spurious INT 5 EH PCI Bride Failure 5 EH Serdes Bus Error 7 EH Chess IN Use 7 EH Illegal Chess Release 4 EH Illegal Chess Name 5 NVR MAC ADDR Corruption 5 NVR PROT MEM Corruption 5 NVR General MEM Corruption 4 EH Boot Parm Save Error Page - 284 - of 321 Sep 18, 2020 Rev 4.1 Kulicke & Soffa™ SECS/GEM Interface for K&S Ball Bonders Bonder software version x-xx-x-472-series ALID (U2) 6479 6480 6481 6482 6483 6484 6485 6486 6487 6488 6489 6490 6491 6492 6493 6494 6495 6496 6497 6498 6499 6500 6501 6502 6503 IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Alarms ALTX ALCD Description EH-BOOT-PARMSET-ERR EH-BOOT-PARMRESTORE-ERR EH-INSTALLKERNEL-COPYERR EH-INSTALLPROCESS-ERR VDKError_kUnkno wnThreadType VDKError_kUnkno wnThread VDKError_kThread CreationFailure VDKError_kUnkno wnSemaphore VDKError_kUnkno wnEventBit VDKError_kUnkno wnEvent VDKError_kInvalidP riority VDKError_kInvalid Delay VDKError_kSemap horeTimeout VDKError_kEventTi meout VDKError_kBlockInI nvalidRegion VDKError_kDbgPos sibleBlockInRegion VDKError_kInvalidP eriod VDKError_kAlready Periodic VDKError_kNonperi odicSemaphore VDKError_kDbgPo pUnderflow VDKError_kBadIOI D VDKError_kBadDev iceDescriptor VDKError_kOpenF ailure VDKError_kCloseF ailure VDKError_kReadFa ilure 4 EH Boot Parm Set Error 4 EH Boot Parm Restore Error 5 EH Install Kernel Copy Error 5 EH Install Process Error 6 VDKError kUnknownThreadType 6 VDKError kUnknownThead 6 VDKError kUnknownCreation Failure 6 VDKError kUnknownSemaphore 6 VDKError kUnknownEventBit 6 VDKError kUnknownEvent 6 VDKError kInvalidPriority 6 VDKError kInvalidDelay 6 VDKError kSemaphore Timeout 6 VDKError kEventTimeOut 6 VDKError kBlockInInvalidRegion 6 VDKError kDbgPossibleBlockInRegion 6 VDkError kInvalidPeriod 6 VDKError kAlreadyPeriodic 6 VDKError kNenperiodicSemaphore 6 VDKError kDbgPopUnderFlow 6 VDKError kBadIOID 6 VDKError kBadDeviceDescriptor 6 VDKError kOpenFailure 6 VDKError kCloseFailure 6 VDKError kReadFailure Page - 285 - of 321 Sep 18, 2020 Rev 4.1 Kulicke & Soffa™ SECS/GEM Interface for K&S Ball Bonders Bonder software version x-xx-x-472-series ALID (U2) 6504 6505 6506 6507 6508 6509 6510 6511 6512 6513 6514 6515 6516 6517 6518 6519 6520 6521 6522 6523 6524 6525 6526 6527 6528 IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Alarms ALTX ALCD Description VDKError_kWriteFa ilure VDKError_kIOCtlFa ilure VDKError_kInvalid DeviceFlag VDKError_kDevice Timeout VDKError_kDevice FlagCreationFailure VDKError_kMaxCo untExceeded VDKError_kSemap horeCreationFailure VDKError_kSemap horeDestructionFail ure VDKError_kPoolCr eationFailure VDKError_kInvalidB lockPointer VDKError_kInvalidP oolParms VDKError_kInvalidP oolID VDKError_kErrorPo olNotEmpty VDKError_kErrorM allocBlock VDKError_kMessag eCreationFailure VDKError_kInvalid MessageID VDKError_kInvalid MessageOwner VDKError_kInvalid MessageChannel VDKError_kMessag eTimeout VDKError_kMessag eInQueue TCPError_ENOBU FS TCPError_ETIMED OUT TCPError_EISCON N TCPError_EOPNO TSUPP TCPError_ECONN ABORTED 6 VDKError kWriteFailure 6 VDKError kIOCtlFailure 6 VDKError kInvalidDeviceFlag 6 VDKError kDevice TimeOut 6 VDKError kDevice Flag Creation Failure 6 VDKError kMaxCountExceeded 6 VDKError kSemaphoreCreationFailure 6 VDKError kSemaphoreDestructionFailure 6 VDKError kPoolCreationFailure 6 VDKError kInvalidBlockPointer 6 VDKError kInvalidPoolParms 6 VDKError kInvalidPoolID 6 VDKError kErrorPoolNotEmpty 6 VDKError kErrorMallocBlock 6 VDKError kMessageCreationFailure 6 VDKError kInvalidMessageID 6 VDKError kInvalidMessageOwner 6 VDKError kInvalidMessageChannel 6 VDKError kMessageTimeout 6 VDKError kMessageInQueue 6 TCPError ENOBUFS 6 TCPError ETIMEDOUT 6 TCPError EISCONN 6 TCPError EOPNOTSUPP 6 TCPError ECONNABORTED Page - 286 - of 321 Sep 18, 2020 Rev 4.1 Kulicke & Soffa™ SECS/GEM Interface for K&S Ball Bonders Bonder software version x-xx-x-472-series ALID (U2) 6529 6530 6531 6532 6533 6534 6535 6536 6537 6538 6539 6540 6541 6542 6543 6544 6545 6546 6547 6548 6549 6550 6551 6552 6553 6554 IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Alarms ALTX ALCD Description TCPError_EWOUL DBLOCK TCPError_ECONN REFUSED TCPError_ECONN RESET TCPError_ENOTC ONN TCPError_EALREA DY TCPError_EINVAL TCPError_EMSGSI ZE TCPError_EPIPE TCPError_EDESTA DDRREQ TCPError_ESHUTD OWN TCPError_ENOPR OTOOPT TCPError_EHAVE OOB TCPError_ENOME M TCPError_EADDR NOTAVAIL TCPError_EADDRI NUSE TCPError_EAFNOS UPPORT TCPError_EINPRO GRESS TCPError_ELOWE R TCPError_KN_EBA DF TCPError_EIEIO PBI_BALL_RETEA CH_REQUIRED EH_EJECT_MAG_ FLASH O_MAG_EJECT_T HRESHOLD_WAR NING_HEADER INV_POWERSAVE _PRM_DATA_PTR PAD-FOR-PBINOT-FOUND BALL-EXPECTOUT-OF-PAD 6 TCPError EWOULDBLOCK 6 TCPError ECONNREFUSED 6 TCPError ECONNRESET 6 TCPError ENOTCONN 6 TCPError EALREADY 6 6 TCPError EINVAL TCPError EMSGSIZE 6 6 TCPError EPIPE TCPError EDESTADDRREQ 6 TCPError ESHUTDOWN 6 TCPError ENOPROTOOPT 6 TCPError EHAVEOOB 6 TCPError ENOMEM 6 TCPError EADDRNOTAVAIL 6 TCPError EADDRINUSE 6 TCPError EAFNOSUPPORT 6 TCPError EINPROGRESS 6 TCPError ELOWER 6 TCPError KN_EBADF 6 7 TCPError EIEIO PBI Ball Reteach Required 7 EH Eject Mag Flash 6 Output Mag Eject Threshold Warning Header 4 INV Powersave PRM Data PTR 7 Pad For PBI Not Found 7 Ball Expect Out Of Pad Page - 287 - of 321 Sep 18, 2020 Rev 4.1 Kulicke & Soffa™ SECS/GEM Interface for K&S Ball Bonders Bonder software version x-xx-x-472-series ALID (U2) 6555 6556 6557 6558 6559 6560 6561 6562 6563 6564 6565 6566 6567 6568 6569 6570 6571 6572 6573 6574 6575 6576 IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Alarms ALTX ALCD Description EH_AUTO_CONSE CUTIVE_FALSE_P RS_NSOP AUTO_XHAIR_MA P_INACTIVE BHLIFTER_AIR_A UTO BHLIFTER_AIR_M STOP EH_INIT_FOCUS_ MOTOR_STEPPE R_FAILED EH_FATAL_IDX_N OT_FOUND IND_NO_CLAMP_ VACUUM_CONT IND_CLAMP_VAC UUM_OFF_FAIL RAIL_LIMIT_AT_B ONDSITE RAIL_LIMIT_OUTS IDE_BONDSITE AUTO-WIREUSAGE-EXPIRY EH-INSTALL-USBCOPY-ERROR RWH_PN_CMD_F AILURE MHS_INDEXER_E XCEED_WHL_LIMI T IMH_UNLOAD_FAI L OMH_UNLOAD_FA IL MH_WAIT_STORE _MAG MH_WAIT_STORE _MAG_O EJECT_INPUT_MA GAZINE_NOT_EM PTY MH_LOAD_MAG_P USHER_PUSH_FA IL MH_LOAD_MAG_P USHER_PUSH_FA IL_O MH_UNLOAD_MA G_PUSHER_PUSH _FAIL 4 EH Auto Consecutive False PRS NSOP 6 Auto Xhair Map Inactive 6 BHLIFTER AIR Auto 6 BHLIFTER AIR Mstop 6 EH INIT Focus Motor Stepper Failed 7 EH Fatal IDX Not Found 6 IND No Clamp Vacuum Cont 3 IND Clamp Vacuum Off Failure 2 Rail Limit At bondsite 2 Rail Limit Outside Bondsite 7 Auto Wire Usage Expiry 3 EH Install USB Copy Error 4 RWH PNC MD Failure 2 MHS Indexer Exceed WHL Limit 7 IMH Unload Failure 7 OMH Unload Failure 7 MH Wait Store Magazine 7 MH Wait Store Output Magazine 7 Eject Input Magazine Not Empty 3 MH Load MAG Pusher Push Failure 3 MH Load MAG Pusher Push Failure O 3 MH Unload MAG Pusher Push Failure Page - 288 - of 321 Sep 18, 2020 Rev 4.1 Kulicke & Soffa™ SECS/GEM Interface for K&S Ball Bonders Bonder software version x-xx-x-472-series ALID (U2) 6577 6578 6579 6580 6581 6582 6583 6584 6585 6586 6587 6588 6589 6590 6591 6592 6593 6594 6595 6596 6597 6598 6599 IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Alarms ALTX ALCD Description MH_UNLOAD_MA G_PUSHER_PUSH _FAIL_O MH_LOAD_MAG_P USHER_RETRACT _FAIL MH_LOAD_MAG_P USHER_RETRACT _FAIL_O MH_UNLOAD_MA G_PUSHER_RETR ACT_FAIL MH_UNLOAD_MA G_PUSHER_RETR ACT_FAIL_O AUTO-LOCATORFIND-FAIL STRIP_MAP_DL_T IMEOUT STRIP_MAP_DL_F AIL STRIP_MAP_INVA LID_SIZE MHS_GRIP_THET A_BIAS_FAIL EH-USB-PWSMATROX-DROP STRIP_MAP_INVA LID_ORG_LOC PARAM_RULE_ER R EH_GUIDE_SENS OR_NOT_SAFE EH_GUIDE_SENS OR_NOT_SAFE_O NKG_DONGLE_C HECK_ERROR STRIP_MAP_HOS T_REPLY_HALT RLS_UNBIAS_FAIL ED MON-UPS-LOWBATTERY PROCESS-BP-HIT AUTO-DRPCHECK-FAIL EH_AUTO_TEMP_ OVER_HI_LIMIT_LI NK EH_AUTO_TEMP_ UNDER_LOW_LIMI T_LINK 3 MH Unload MAG Pusher Push Failure O 3 MH Load Mag Pusher Retract Failure 3 MH Load Mag Pusher Retract Failure O 3 MH Unload Mag Pusher Retract Failure 3 MH Unload Mag Pusher Retract Failure O 3 Auto Locator Find Failure 3 Strip Map DL Timeout 3 Strip Map DL Failure 4 Strip Map Invalid Size 2 MHS Grip Theta Bias Failure 6 EH USB PWS Matrox Drop 4 Strip Map Invalid ORG LOC 4 Param Rule Error 2 EH Guide Sensor Not Safe 2 EH Guide Sensor Not Safe O 6 NKG Dongle Check Error 3 Strip Map Host Reply Halt 2 RLS UNBIAS Failure 6 MON UPS Low Battery 7 3 Process BP HIT Auto DRP Check Failure 2 EH Auto Temp Over HI Limit Link 2 EH Auto Temp Under Low Limit Link Page - 289 - of 321 Sep 18, 2020 Rev 4.1 Kulicke & Soffa™ SECS/GEM Interface for K&S Ball Bonders Bonder software version x-xx-x-472-series ALID (U2) 6600 6601 6602 6603 6604 6605 6606 6607 6608 6609 6610 6611 6612 6613 6614 6615 6616 6617 6618 6619 6620 6621 6622 IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Alarms ALTX ALCD Description EH_AUTO_TEMP_ OVER_HI_LIMIT_O PTICS EH_AUTO_TEMP_ UNDER_LOW_LIMI T_OPTICS STRIP_MAP_HOS T_REPLY_ERROR EH_SUB_VALIDAT ION_FAILED CAP_CLEANING_ REACHING_LIMIT EH_DISK_SPACE_ FULL EH_DISK_SPACE_ NOT_FULL EH_TEMP_OVER_ MAX_LIMIT I2C_BUS_ERROR PDT-PULLTSTINIT-ERR CAL_XHAIR_MAP_ UNSUCCESSFUL AUTO_COVER_GA S_BACK_PRESSU RE_HIGH AUTO_COVER_GA S_BACK_PRESSU RE_LOW PDTUNEXPECTEDNSOP-TIP2 EH-PDT-LGBALL EH_HB_HIT_RAIL_ LIMIT_SWITCH EH_BALL_TAIL_IN VALIDATION EH_STRIP_MAP_I NVALID EH_NFS_MOUNT_ FAIL_ERROR EH_NSOL_AUTO_ REBOND_ATTEMP TED EH_NSOL_AUTO_ REBOND_FAILED PUSHER_KIT_RET RACT_FAILURE EH_UNKNOWN_C ELL_VERIFICATIO N 2 EH Auto Temp Over HI Limit Optics 2 EH Auto Temp Under Low Limit Optics 3 Strip Map Host Reply Error 3 EH SUB Validation Failed 7 Cap Cleaning Reaching Limit 7 EH Disk Space Full 7 EH Disk Space Not Full 2 EH Temp Over Max Limit 6 3 I2C BUS Error Pull Test initialization error 6 Cal Xhair map unsuccessful 6 Digital cover gas back pressure too high 6 Digital cover gas back pressure too low 3 Unexpected NSOP TIP2 2 2 PDT Large Ball Heatblock hit rail limit switch 6 The ball or tail is invalidate 3 Strip map is invalid 6 NFS mount failed 6 NSOL Auto rebond attempted 6 NSOL Auto rebond failed 3 Error when pusher kit encounter error during retract 3 Unknown cell found(strip map only) Page - 290 - of 321 Sep 18, 2020 Rev 4.1 Kulicke & Soffa™ SECS/GEM Interface for K&S Ball Bonders Bonder software version x-xx-x-472-series ALID (U2) 6623 6624 6625 6626 6627 6628 6629 6630 6631 6632 6633 6634 6635 6636 6637 6638 6639 6640 6642 6643 IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Alarms ALTX ALCD Description AUTO-ALIGNFIND-FAILPARTIALBONDED-DEV WIRE_CLAMP_PM _LIMIT_EXCEEDE D EH_SAFETY_COV ER_KIT_FAILURE FLUID_RATE_LIMI T_EXCEEDED EH_PRH_VACUU M_ON_FAIL EH_RAILS_HOME _SEEK_FAIL EH_AIR_BLOWER _OUTOF_LIMIT_W _CONT EH_AIR_BLOWER _OUTOF_LIMIT EH_ORIENT_EYE_ POINT_NOT_FOU ND EH_PERIODIC_EF O_HEIGH_CHECK _FAIL EH_PERIODIC_EF O_HEIGH_CHECK _OUT_OF_LIMIT CE_SOS_EVENT EH_MHS_OHT_EX EC_SEQ_ERR EH_INPUT_MAG_ EJECT_INHIBITED EH_OUTPUT_MAG _EJECT_INHIBITE D EH_INPUT_MAG_ EJECT_HOST_VA LIDATION_TIMEO UT EH_OUTPUT_MAG _EJECT_HOST_V ALIDATION_TIME OUT EH_WEDGE_VALI DATION_CHECK_ FAIL EH_SUBSTRATE_ MAP_PARSE_FAIL CMP_COVER_HO ME_NOT_FOUND 3 ALIGN status - inadequate eye points found #FEA3601 6 WIRE CLAMP PM LIMIT EXCEEDED 2 Safety Cover is open 6 ALID for fluid rate out of limit 3 Preheat Vacuum is not present 0 Rails Home Seek Fail 6 Air Blower Flow Rate Out Of Limit 6 Air Blower Flow Rate Out Of Limit 5 Search Orientation eye point failded 6 Periodic EFO height calibration fails 6 Periodic EFO height calibration out of limit 7 6 Alarm for SOS event OHT Sequence Failure 6 Host disallow input mag ejection 6 Host disallow output mag ejection 6 Host does not reply input mag eject request within timeout 6 Host does not reply output mag eject request within timeout 6 Event of wedge validation checking fail 5 Parse Substrate Map Failed 6 Clamp cover home not found Page - 291 - of 321 Sep 18, 2020 Rev 4.1 Kulicke & Soffa™ SECS/GEM Interface for K&S Ball Bonders Bonder software version x-xx-x-472-series ALID (U2) 6644 6645 6646 6647 6648 6649 6650 6651 6652 6653 6654 6655 6656 6657 6658 6659 6660 6661 6662 6663 6664 6665 IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Alarms ALTX ALCD Description CMP_COVER_NO T_OUT_OF_HOME EH_HB_SECURE_ VACUUM_FAIL EH_GCK_GAS_LO W EH_GCK_GAS_LO W_IN_BONDING EH_MAG_MOTION _INTERRUPT PUSHER_KIT_HO ME_SENSOR_ER ROR EH_FOCUS_ADJ_ OUT_OF_LIMIT PDTRPMOUTLIERERROR EH_CNG_BOND_C OUNTERS_EXCEE DED EH_CNG_BOND_C OUNTERS_STOP_ AUTO EH_FAINT6_GUI_ ERR EH_REALTIME_RP M_ERROR EH_CLXC_BASE_ TEMP_THRESHOL D_EXCEEDED EH_MH_CHUTE_C LAMP_FAILED EH_MH_CHUTE_C LAMP_FAILED_O STRIP_ID_NOT_F OUND_IN_LOCAL_ SERVER PDT-DIE-HEIGHTOVER-LIMIT EH_BATTERY_ST S_SETTING_MISM ATCH_ERROR AUTO_CALIBRATI ON_NEAR_EXPIR ATION AUTO_CALIBRATI ON_EXPIRED AUTO_CALIBRATI ON_EXPIRED_ST OP_INJECT MDS_FAULT_DET ECTED 6 Clamp cover is not out of home 6 Heat block secure vacuum not detected error 6 Tunnel gas low 6 Workholder Cover Gas Low During Bonding 6 Magazine motion is interrupted 2 Alarm: Pusher Kit home sensor has some error 3 Event #2378 Focus adjustment out of limit 3 Bonding stopped due to RPM single outlier error 7 Configured bond counter limit exceed 7 Configured bond counter limit exceed and stop auto 3 GUI Task Exception. Machine reboot is required 3 Realtime RPM error alarm 3 CLXC base temperature threshold exceeded error 6 Input chute clamp failed 6 Output chute clamp failed 4 strip ID not found in local server 3 PDT DIE Height Over Limit 6 Battery installation status does not match to battery setting in subsystem selection 7 A machine calibration is near expiration. 7 A machine calibration has expired. 3 A machine calibration has expired and Strip Inject will be disabled until it is performed. 8 Machine Data Collection Fault Page - 292 - of 321 Sep 18, 2020 Rev 4.1 Kulicke & Soffa™ SECS/GEM Interface for K&S Ball Bonders Bonder software version x-xx-x-472-series ALID (U2) 6666 6667 6668 6669 6670 6671 6672 6673 6675 6676 6677 6678 6679 6680 6681 6682 6683 6684 6685 6686 IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Alarms ALTX ALCD Description MH_BUFFER_RAIL _NOT_EMPTY MH_BUFFER_RAIL _NOT_EMPTY_O MH_INDEXER_RAI L_NOT_EMPTY MH_INDEXER_RAI L_NOT_EMPTY_O MH_BUFFER_RAIL _CRR_NOT_READ Y MH_BUFFER_RAIL _CRR_NOT_READ Y_O MH_INDEXER_RAI L_CRR_NOT_REA DY MH_INDEXER_RAI L_CRR_NOT_REA DY_O EH_COMM_DOWN _BEFORE_UPLOA D_STRIP_MAP PDT_UNEXPECTE D_NSOP_MISSING _BOND EH_STITCH_LIFT_ DETECTED ACCESS_VIOLATI ON_INPUT_LOAD ACCESS_VIOLATI ON_OUTPUT_LOA D PDTUNEXPECTEDSTITCH-LIFT PDTUNEXPECTEDSTITCH-BREAK PDTUNEXPECTEDSTITCH-LIFTBREAK MDS_DATA_PURG E_EVENT EH_INVALID_STRI P_MAP KNS_CONNECT_E RROR EH_LAST_WIRE_N SOL_REBOND_BE F_SKIP_DEV 6 Loader’s buffer rail is not empty 6 Unloader’s buffer rail is not empty 6 Loader’s indexer rail is not empty 6 Unloader’s indexer rail is not empty 6 On loader’s buffer rail, carrier is not placed properly 6 On unloader’s buffer rail, carrier is not placed properly 6 On loader’s indexer rail, carrier is not placed properly 6 On unloader’s indexer rail, carrier is not placed properly 4 ALID for the event error: comm down before upload strip map 3 A missing bond has detected by bond monitor 3 Lifted stitch bond is detected by Stitch Lift Detection Feature 6 Input mag is placed by operator manually on load tray under Auto access mode Output mag is placed by operator manually on load tray under Auto access mode 6 3 PDT Stitch Lift error 3 PDT Stitch Break error 3 PDT Stitch Lift/Break error 8 User warning before purging machine data 3 Alarm ID for EH_INVALID_STRIP_MAP 8 KNS Connect Error 3 Last Wire NSOL Rebond warning before auto skip device. Page - 293 - of 321 Sep 18, 2020 Rev 4.1 Kulicke & Soffa™ SECS/GEM Interface for K&S Ball Bonders Bonder software version x-xx-x-472-series ALID (U2) 6687 6688 6689 6690 6691 6692 6693 6694 6695 6696 6697 6698 6699 6700 6701 6702 6703 6704 6705 6706 6707 IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Alarms ALTX ALCD Description EH_AUTO_LHM_M AX_LOOP_HT_EX CEED_WARN_LIMI T EH_AUTO_LHM_M AX_LOOP_HT_EX CEED_ERR_LIMIT EH_AUTO_LHM_E DGE_HEIGHT_EX CEED_WARN_LIMI T EH_AUTO_LHM_E DGE_HEIGHT_EX CEED_ERR_LIMIT EH_AUTO_LHM_R ESULT_VALIDATI ON_TIMEOUT EH_AUTO_LHM_R ESULT_VALIDATI ON_FAILED EH_AUTO_LHM_R ESULT_VALIDATI ON_REJECTED MH_MAG_SEPAR ATION_ERR MH_MAG_SEPAR ATION_ERR_O MH_PLATFORM_N OT_EMPTY MH_PLATFORM_N OT_EMPTY_O MH_FORK_NOT_E MPTY MH_FORK_NOT_E MPTY_O MH_PLATFORM_C RR_NOT_READY MH_PLATFORM_C RR_NOT_READY_ O MH_FOKR_CRR_N OT_READY MH_FOKR_CRR_N OT_READY_O LOADER_BENCH_ SEQ_ERROR EH_SAFETY_INIT_ FAILED EH_NSOL_REBON D_BEF_SKIP_DEV _FAILED AIR_OUT_OF_TOL ERANCE 3 Maximum loop height exceeds warning limit 3 Maximum loop height exceeds error limit 3 Edge height exceeds warning limit 3 Edge height exceeds error limit 3 LHM: Result validation timeout 3 LHM: Result validation failed 3 LHM: Result rejected by host 5 6 Input magazine detect magazine not separated during unloading Output magazine detect magazine not separated during unloading Loader’s platform is not empty 6 Unloader’s platform is not empty 6 Loader’s fork is not empty 6 Unloader’s fork is not empty 6 On loader’s platform, carrier is not placed properly. 6 On unloader’s platform, carrier is not placed properly. 6 On loader’s fork, carrier is not placed properly. 6 On unloader’s fork, carrier is not placed properly. 6 Benching operation in loading sequence fails 2 Safety module initialize failed 3 NSOL Rebond Before Skip Device Failed 8 Air pressure tolerance exceeded 5 Page - 294 - of 321 Sep 18, 2020 Rev 4.1 Kulicke & Soffa™ SECS/GEM Interface for K&S Ball Bonders Bonder software version x-xx-x-472-series ALID (U2) 6708 6709 6710 6711 6712 6713 6714 6715 6716 6717 6718 6719 6720 6722 6723 6724 6725 6726 6727 6728 IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Alarms ALTX ALCD Description EH_OUTPUT_KIC K_HOME_NOT_FO UND EH_OUTPUT_KIC K_NOT_OUT_OF_ HOME EH_LEFT_CLAW_ HOME_NOT_FOU ND EH_LEFT_CLAW_ NOT_OUT_OF_HO ME EH_RIGHT_CLAW _HOME_NOT_FOU ND EH_RIGHT_CLAW _NOT_OUT_OF_H OME EH_INPUT_KICK_ HOME_NOT_FOU ND EH_INPUT_KICK_ NOT_OUT_OF_HO ME EH_BK_CLAMP_H OME_NOT_FOUN D EH_DOUBLE_LF_ DETECTED EH_INPUT_LF_JA M EH_MH_MAG_NO T_ON_INDEXER EH_MH_MAG_NO T_ON_INDEXER_ O EH_MH_MAG_WR ONG_ORIENTATI ON EH_MH_MAG_WR ONG_ORIENTATI ON_O EH_MH_MAGAZIN E_DROPPED EH_MH_MAGAZIN E_DROPPED_O PDT-EFOTHRESHOLDFAULT EH_PART_REJEC TED_BY_HOST EH_PART_BLOCK ED_BY_HOST 6 Output kicker home not found 6 Output kicker not out of home 6 Left claw home not found 6 Left claw not out of home 6 Right claw home not found 6 Right claw not out of home 6 Input kicker home not found 6 Input kicker not out of home 6 Clamp home not found 6 Double LF detected 6 Input LF jammed 6 Input mag not on indexer 6 Output mag not on indexer 6 Input mag wrong oritentation 6 Output mag wrong orientation 6 Input mag dropped 6 Output mag dropped 6 EFO Limit Exceeded Fault 3 Host reject next part 3 Blocked for next part Page - 295 - of 321 Sep 18, 2020 Rev 4.1 Kulicke & Soffa™ SECS/GEM Interface for K&S Ball Bonders Bonder software version x-xx-x-472-series ALID (U2) 6729 6730 6731 6732 6733 6735 6736 6737 6738 6739 6740 6741 6742 6743 6744 6745 6746 6747 6748 6749 6750 IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Alarms ALTX ALCD Description EH_PART_WARNI NG_BY_HOST EH_PART_MAP_D LOAD_TIMEOUT EH_PART_MAP_D LOAD_FAIL PART_PROCESS_ RSLT_REJECTED _BY_HOST PART_PROCESS_ RSLT_VALIDATIO N_TIMEOUT EH_WALL_SENSO R_CHECK_FAIL_D URING_EJECT_LF INPUT_CONVEYO R_COMM_ERROR OUTPUT_CONVEY OR_COMM_ERRO R INPUT_CONVEYO R_COMM_TIMEOU T OUTPUT_CONVEY OR_COMM_TIME OUT INPUT_CONVEYO R_ERROR OUTPUT_CONVEY OR_ERROR INPUT_CONVEYO R_WAIT_UPSTRE AM_TIMEOUT OUTPUT_CONVEY OR_WAIT_DOWN STREAM_TIMEOU T CONVEYOR_SAFE TY_COVER_OPEN PREHEAT_NOT_U P PREHEAT_NOT_D OWN INPUT_CONVEYO R_NOT_READY OUTPUT_CONVEY OR_NOT_READY INPUT_CONVEYO R_COMM_TIMEOU T_2 OUTPUT_CONVEY OR_COMM_TIME OUT_2 3 Warning for next part 3 partReceive timeout 3 partReceive fail 3 Host reject processed part 3 partProcessed timeout 2 ALID for the event error: output wall sensor checks failed during ejecting L/F 6 Input conveyor communication error 6 Output conveyor communication error 6 Input conveyor communication timeout 6 Output conveyor communication timeout 6 Input conveyor error 6 Output conveyor error 6 Input conveyor waits for upstream timeout 6 Output conveyor waits for downstream timeout 6 Conveyor safety cover open 6 Preheat blade does not move up 6 Preheat blade does not move down 6 Input conveyor is reset and not ready to run 6 Output conveyor is reset and not ready to run 6 Input conveyor communication timeout (incoming command) 6 Output conveyor communication timeout (incoming command) Page - 296 - of 321 Sep 18, 2020 Rev 4.1 Kulicke & Soffa™ SECS/GEM Interface for K&S Ball Bonders Bonder software version x-xx-x-472-series ALID (U2) 6751 6752 6753 6754 6755 6756 6757 6758 6759 6760 6761 6762 6763 6764 6765 6766 6767 6768 6769 6770 6771 6772 6773 IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Alarms ALTX ALCD Description EH_NSOP_SKIP_D EV_BY_BOND_NE XT_WIRE_FAILED EXT_2D_BCR_RE AD_FAIL REMOTE_PARMS _UPLOAD_FAIL REMOTE_PARMS _DOWNLOAD_FAI L OUT_SLOT_LF_D ETECTED OMH_LF_RETAIN ER_NOT_IN_POS PDT_PULLTST_O UT_OF_LIMIT OUT_SLOT_LF_D ETECTED_2 EH_BOFF_POS_IN VALID EH_MAG_SERVIC E_POSI_NEED_RE TURN RPM_HEALTH_WA RNING RPM_NO_COMMS RPM_SUBSYSTE M_HEALTH_WAR NING RPM_ANALYTICS_ FAULT EH_Z_LINK_WAR M_UP_ABORT BH_CI_COLL_PRE _CONDITION_ERR INPUT_LF_PICKU P_HOME_NOT_FO UND INPUT_LF_PUSHE R_HOME_NOT_FO UND OUTPUT_LF_GRIP PER_HOME_NOT_ FOUND INPUT_MH_EMPT Y_FORK INPUT_LF_PICKU P_DETECT_FAIL INPUT_LF_DROP_ ACTION_FAIL INPUT_LF_STAND BY_ACTION_FAIL 3 NSOP Skip Device by Bond Next Wire Failed 5 External 2D BCR read fail 6 Remote parameter upload failure 6 Remote parameter download failure 5 Out slot LF detected 5 OMH LF retainer not in position 2 ALID for the event error: Pull Test Out of Limit Error 5 Out slot LF detected for lot separation case 7 Bond Off Position Invalid 6 Find event EH_MAG_SERVICE_POSI_NEED_RETURN 6 RPM system unresponsive 6 6 Unable to communicate with RPM system RPM subsystem unresponsive 6 RPM Analytics sytem error 6 ALID for the event error: Z-link warm up sequence is aborted 6 Bondhead clamp insert collision pre-condition check fails 6 VLF fork type input pickup home sensor not found 6 VLF fork type input pusher home sensor not found 6 VLF fork type output gripper home sensor not found 6 VLF fork type on-loader has no fork 6 VLF fork type input pickup fail to get lead frame 6 VLF fork type input pickup fail to drop lead frame on track 6 VLF fork type input pickup fail to go to standby position Page - 297 - of 321 Sep 18, 2020 Rev 4.1 Kulicke & Soffa™ SECS/GEM Interface for K&S Ball Bonders Bonder software version x-xx-x-472-series ALID (U2) 6774 6775 6776 6777 6778 6779 6780 6781 6782 6783 6784 6785 6787 6788 6789 6790 6791 6792 6793 6794 6795 IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Alarms ALTX ALCD Description INPUT_LF_PUSH_ ACTION_FAIL OUTPUT_MH_EM PTY_FORK OUTPUT_LF_GRIP _ACTION_FAIL CI_SAFE_POS_SN S_DETECT ACC_ALIGNMENT _ERROR ACC_ROBOT_ERR OR RPM_DATAVIZ_FA ULT EH_PP_AUTO_CO NV_FAIL PREHEAT_VAC_N OT_ON PREHEAT_VAC_N OT_OFF EH_IDLE_PROMP T_EJECT_LF_TIM EOUT EH_CD_SKIP_PR OC_LIMIT_EXCEE DED INPUT_SMEMA_S TART_TRANSFER _TIMEOUT INPUT_SMEMA_E ND_TRANSFER_TI MEOUT INPUT_SMEMA_IN VALID_ACK_SIG_ STATE WIRE-INSP-WIRESTOP-ERR 6 VLF fork type input pusher fail to push lead frame in 6 VLF fork type off-loader has no fork 6 VLF fork type output gripper action fail 6 Clamp Insert Safe Position sensor is detected 6 Fail to find ACC alignment eyepoint 6 Auto cap changer reports error during cap change process 6 RPM DATAVIZ FAULT 6 5 ALID for the event error: process program auto conversion is failed. Preheat vacuum not on 5 Preheat vacuum not off 6 for EH EH_IDLE_PROMPT_EJECT_LF_TIMEOUT (Idle Mode ECO Prompt To Eject Leadframes time out) 3 CD skipped processing - exceed limit 7 Input smema start transfer timeout error 7 Input smema end transfer timeout error 8 Input smema invalid acknowledgement signal state error 2 Alarm ID for EH #2560 Out of tolerance detected during Wire Inspection by wire. WIRE-INSP-UNITSTOP-ERR WIRE-INSPEXCEED-WARNLIMIT WIRE-INSPREALIGNFAILURE EH_Z_LINK_WAR M_UP_COMPLETE D WIRE-INSP-IDNOT-TAUGHT 2 2 Out of tolerance detected during Wire Inspection by wire. Alarm ID for EH #2561, Out of tolerance detected during Wire Inspection by unit. Alarm ID for EH #2562, Exceed warn limit during Wire Inspection. 2 Alarm ID for EH #2563 Wire Inspection align failure. 6 Z-link warm up completion 2 Alarm ID for WIRE_INSP_ID_NOT_TAUGHT Wire Inspection ID not taught Page - 298 - of 321 Sep 18, 2020 Rev 4.1 Kulicke & Soffa™ SECS/GEM Interface for K&S Ball Bonders Bonder software version x-xx-x-472-series ALID (U2) 6799 IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Alarms ALTX ALCD Description EH_AUTO_LHM_L OOP_HEIGHT_INV ALID 6 Auto loop height measurement too low or missing Figure 61 – K&S Model Power Series Automatic Ball Bonder and K&S Model Gen-S Automatic Ball Bonder Shared Alarms 6.6 K&S Model Power Series Automatic Ball Bonder and K&S Model Gen-S Automatic Ball Bonder Shared Data Values The Data Values (DVVALs) and associated Data Value IDs (DVIDs) shared by K&S Model Power Series Automatic Ball Bonder and K&S Model Gen-S Automatic Ball Bonder are described in this section. IConn/IConn+/ConnX/ConnX+/ConnXLED/ProCu/ProCu+ Shared Data Values DVID Name Type Description (U2) 10000 DVVAL_LimitVariab U2[1] Used with the Limits Monitoring capability, contains the SVID le for the status variable whose value changed monitoring zones. 10001 DVVAL_TransitionT B[1] Used with the Limits Monitoring capability, defines the direction ype of the zone transition which has occurred. 0 = Transition from lower to upper zone. 1 = Transition from upper to lower zone. 10002 DVVAL_EventLimit B[1] Used with the Limits Monitoring capability, contains the LIMITID of the limit reached or crossed by LimitVariable. Since multiple zone transitions for a variable may occur simultaneously, EventLimit has been defined to allow for a list of LIMITIDs. 10003 DVVAL_ChangedE U2[1] Contains the ECID of the equipment constant whose value has C been changed by the operator. 10004 DVVAL_Assist_ALI U2[1] Assist Alarm ID D 10005 DVVAL_Assist_Rea U1[1] Assist reason son 10006 DVVAL_Assist_Tex A[N] Assist text t 10007 DVVAL_Assist_Tim U4[1] Assist time e 10008 Temperature_Auto_ U1[1] Temperature Auto Tune Tune 10009 DVVAL_LATEST_A U2[1] Latest ALID LID 10010 DVVAL_LATEST_A A[N] Latest ALTX LTX 10011 DVVAL_SINGLE_I A[N] DVVAL SINGLE INTERACTIVER TM ID NTERACTIVER_T M_ID 10012 DVVAL_SINGLE_I A[N] DVVAL SINGLE INTERACTIVER SELECT NAME NTERACTIVER_S ELECT_NAME 10013 DVVAL_SUBSTRA A[N] DVVAL SUBSTRATE MAP DATA TE_MAP_DATA Figure 62 – K&S Model Power Series Automatic Ball Bonder and K&S Model Gen-S Automatic Ball Bonder Shared Data Values Page - 299 - of 321 Sep 18, 2020 Rev 4.1 Kulicke & Soffa™ SECS/GEM Interface for K&S Ball Bonders Bonder software version x-xx-x-472-series Page - 300 - of 321 Sep 18, 2020 Rev 4.1 Kulicke & Soffa™ SECS/GEM Interface for K&S Ball Bonders Bonder software version x-xx-x-472-series 6.7 K&S Model Power Series Automatic Ball Bonder and K&S Model Gen-S Automatic Ball Bonder GEM Compliance Statement K&S Model Power Series Automatic Ball Bonder and K&S Model Gen-S Automatic Ball Bonder GEM COMPLIANCE STATEMENT Fundamental GEM Requirements Implemented GEM Compliant State Models yes no Equipment Processing States yes no Host-Initiated S1F13/F14 Scenario yes no yes Event Notification yes no On-line Identification yes no no Error Messages yes no Documentation yes no Control (Operator-Initiated) yes no Additional Capabilities Implemented GEM Compliant Establish Communications yes no yes no Dynamic Event Report Configuration yes no yes no Variable Data Collection yes no yes no Trace Data Collection yes no yes no Status Data Collection yes no yes no Alarm Management yes no yes no Remote Control yes no yes no Equipment Constants yes no yes no Process Program Management yes no yes no Material Movement yes no yes no Equipment Terminal Services yes no yes no Clock yes no yes no Limits Monitoring yes no yes no Spooling yes no yes no Control (Host-Initiated) yes no yes no Strip Mapping (Premium Option) yes no yes no Figure 63 – K&S Model Power Series Automatic Ball Bonder and K&S Model Gen-S Automatic Ball Bonder GEM Compliance Statement 7. APPENDIX 3 - Summary of Software Changes This section is a summary of the software changes applicable to SECS/GEM functionality. Added remote command RCMD_DO_INDEX, RCMD_LF_IN_OUT, and RCMD_JOG_EJECT_MAG to Section 4.6.1 Updated remote commands ACCEPT_IN_MAG, ACCEPT_OUT_MAG, REJECT_IN_MAG, and REJECT_OUT_MAG in the section 4.6.1. Added 3319-3327, 3417-3418, 3621-3622, 3800-3830, and 4016-4029 to Section 6.2 Added 1098-1099, 1246, 1198-1199, 1239, 1403, 1508-1510, and 1603 to Section 6.3 Added 8050, 8335-8336, 8342-8343, 8402-8408, 8420, 8430-8431, 8440, 9012, 9492, 9502, 9512, 9760-9761, 10990-10991, 11090-11091, 11100-11101, 11110-11111, 11120-11121, 11130-11131, 11140-11141 and 1115011151 to Section 6.4 Added 6209-6215 to Section 6.5 Added S14F1 and S14F2 SECS-II message transaction. Added strip map upload/download scenario, and HDL_BOND_POSITION in data set transfer scenario. Added 3840 – 3844, 3850 – 3853 in Section 6.2 Removed 3822, 3823, 3024, 3025 in Section 6.2 Page - 301 - of 321 Sep 18, 2020 Rev 4.1 Kulicke & Soffa™ SECS/GEM Interface for K&S Ball Bonders Bonder software version x-xx-x-472-series Updated 3045, 3051, 3052, 3062, 3064, 3116, 3118, 3323, 3327 in Section 6.2 Added 1511-1514 in Section 6.3 Updated 1050, 1103, 1398, 1399, 1422 in Section 6.3 Removed 1004, 1603 in Section 6.3 Added 8450 – 8453, 8460, 8470 in Section 6.4 Updated 8130, 8200, 8201, 8202, 8322 – 8331, 8402 – 8405 in Section 6.4 Removed 8005, 8009, 8015 in Section 6.4 Added 6216 – 6218, 6200 in Section 6.5 Updated 6212 in Section 6.5 Added S10F1/F2 in Section 2.1 Added S14F1/F2 in Section 2.1 Added S10F1/F2 in Section 3.3 Updated MOVE_TO_IDLE in section 4.6 Added Strip Map download scenario in section 4.10 Removed Section 4.17 Updated SECS-II Message Detail for S1F14 in section 3.2.9 Added S14F1/F2 in Section 2.2 Added Remote Command: EXIT_HIT/PROCESS_START/RCMD_MAG_CONFIRM/RCMD_MAG_ID_SCAN_ACK/ RCMD_CLEAR_MAG_ASSIST/RCMD_EQP_STOP/RCMD_SUB_CONFIRM in Section 4.6.1 Added SVID 3119,3326,3361,3362,3363,3405,3406,3420,3421,3625,3823,3824,3825,3831,3854,3855,3856 in section 6.2 Updated SVID 3403,3404 in section 6.2 Added ECID 1120,1121,1130,1192-1197,1247,1449,1450,1452-1458,1515-1604 in section 6.3 Updated ECID 1007,1070-1073,1115,1116,1198,1216,1219-1225,1427-1432,1445 in section 6.3 Added CEID 8025,8133-8135,8153,8154,8344-8347,8350,8360-8369,8432,8454,8461,8462,8471,8472,8480,910015081 in section 6.4 Added ALID 6196-6198,6219,6221-6680 in section 6.5 Added DVID 10009,10010 in section 6.6 Added Scenarios for Calibration Result Data in section 4.10 Added CEID15160/15161/15180/15181/8902/8051/15170/15171/15190/15191/15200/15201/15210/15211/8136/8464 in section 6.4 Added ALID6616/6618/6617/6619/6620/6621 in section 6.5 Added SVID3632/3633/3634/3635/3636/3637/4030/4031/3857/3364/3365/3366/3065/3066 in section 6.2 Added ECID1068/1563/1500 in section 6.3 Updated description for SV3512/CE8140 in section 6.2 and section 6.4 Updated explanation for BOND_PARM_LIMITS in section 4.18.1 Added SVID3829/ECID1125/1126/1127/1128/1129/1131/1132/CEID8115/8116/8117 for FEA3599 Added ALID6623/CEID15230/15231 for FEA3601 Added ALID6622/CEID15220/15221 for FEA3603 Added SVID3871/CEID8373 for FEA3605 Added SVID3067 for FEA3618 Added ECID1564 for KNScq36978 Rev 2.7 (bonder version 458) Added CEID8390 for NFT1356 Added CEID15270/15271/ALID6627 for FEA3664 Added ECID1525 for FEA3666 Added ECID1575 for FEA3670 Added SVID 3650 for FEA3688 Added ECID 1140 for FEA3692 Rev 2.8 (bonder version 459) Add ALID6628/CEID15280/15281 for FEA3703 Add ECID1576 for FEA3709 Add ALID6629/6630/CEID15290/15291/15300/15301 for FEA3715 Add CEID8118 for FEA3716 Page - 302 - of 321 Sep 18, 2020 Rev 4.1 Kulicke & Soffa™ SECS/GEM Interface for K&S Ball Bonders Bonder software version x-xx-x-472-series Rev 2.9 (bonder version 460) Add CEID8338/CEID8339/CEID8340/CEID8341for NFT1374 Add CEID8348/CEID8349 for FEA3726 Add SVID3350/CEID8015 for FEA3737 Add CEID9870/CEID9871/CEID9880/CEID9881/CEID9890/CEID9891/CEID9900/CEID9901 for KNScq38374 Add ALID6087/ALID6088/ALID6089/ALID6090 for KNScq38374 Add ECID1150/ECID1151/ECID1152/ECID1153/ECID1154/ECID1155/ECID1156/ECID1157/ECID1158 /ECID1159 for FEA3775 Add SVID3638 for FEA3723 Add ECID1577/ECID1578 and CEID15340/CEID15341/CEID16210/CEID16211 and ALID6634 for FEA3721 Add CEID15310/CEID15311 and ALID6631 for FEA3774 Add ECID1580 and CEID8481/CEID8482/CEID8483/CEID8484/CEID8485/CEID8486/CEID8487/CEID8488 for FEA3736 Add CEID 15320/CEID15321/CEID15330/CEID15331/CEID8422 and ALID6632/ALID6633 for FEA3773 Rev 3.0 (bonder version 461) Add ECID1579 for CEN1415 Add SVID3639 for CEN77 Add ECID1459 for CEN1423 Add SVID3068 for CEN1499 Add SVID3790/SVID3791 for CEN1753 Add ECID1581/ECID1582/ECID1583/ECID1584 for CEN1698 Add ECID1585 for CEN1996 Add SVID3874/SVID3875/SVID3876 and CEID8052/ECID8053 for FEA3741 Add ALID6635 and CEID15350/CEID15351 for KNScq38660 Add ALID6636/ALID6637/ALID6638 and CEID8155/CEID8156/CEID15360/CEID15361/CEID15370/CEID15371 /CEID15380/CEID15381/CEID15390/CEID15391 for CEN1991 Add Remote command MAG_EJECT_VERIFICATION for CEN1991 Add ALID6640 and CEID15400/CEID15401 for CEN1479 Add ECID1160/ECID1161 for CEN2421 Add ECID1586 for CEN2784 Rev3.1 (bonder version 462) Add ECID1133/SVID3039/CEID8023 for CEN2663 Add CEID8119 for CEN2713 Add ALID6643/ALID6644/ALID6645 and CEID15430/CEID15431/CEID15440/CEID15441/CEID15450/CEID15451 for CEN94 Add ALID6642 and CEID8352/CEID15420/CEID15421 for CEN1959 Add ALID6648 and CEID15480/CEID15481 for CEN2499 Add ECID1587 and SVID3660/SVID3661 for CEN2754 Add ALID6650 and CEID8016/CEID15500/CEID15501 and ECID1141/ECID1142 for CEN3074 Add ALID6649 and CEID15490/CEID15491 for CEN3096 Add ALID6646/ALID6647 and CEID15460/CEID15461/CEID15470/CEID15471 for CEN3201 Add ECID1605 for CEN3243 Add ECID1588 for CEN4339 Add SVID3310 for KNScq39047 Add “DEFECT_ID_FILE” for 4.16 Data Set Transfer Update Process Program grant status by add ACK 6 other error and ACK 7 No PFF file is installed Update remote control command for 4.6 Rev3.2 (bonder version 463) Add SVID3328 for CEN4261 Add ALID6651 and CEID15510/CEID15511 for CEN3338 Add ALID6652/ALID6653 and CEID15520/CEID15521/CEID15530/CEID15531 for CEN4170 Add ECID1589 for CEN4504 Add ECID1377/ECID1378/ECID1379/ECID1380 for CEN4546 Page - 303 - of 321 Sep 18, 2020 Rev 4.1 Kulicke & Soffa™ SECS/GEM Interface for K&S Ball Bonders Bonder software version x-xx-x-472-series Add ALID6654 and CEID15540/CEID15541 for CEN2465 Add SVID3206/SVID3207/SVID3208/SVID3209/SVID3210/SVID3211/SVID3212/SVID3213/SVID3214 and CEID8203/CEID8204/CEID8205/CEID8206 for CEN4551 Add ALID6655 and CEID15550/CEID15551 for CEN4255 Add ECID1526 for CEN4627 Add ALID6656 and CEID15560/CEID15561 for BBBUG-530 Update RCMD table list in section 4.6 Update Data Set Upload/Download table list in section 4.18 Rev3.3 (bonder version 464) Add CEID8142 and ECID1527 for BBBUG-1363 Add ALID6659 and CEID15590/CEID15591 for BBBUG-1628 Add ALID6609 and CEID15090/CEID15091 for BBBUG-1077 Add ECID1590/ECID1591 for CEN5162 Rev3.4 (bonder version 465) Add ECID1708 and CEID8017/8018 for CEN5642 Add ALID6661 and CEID15610/15611 for CEN5420 Add ALID6660 and CEID15600/15601 for CEN5736 Add ALID6665 and CEID15650/15651 for CEN4956 Add ALID6662/6663/6664 and CEID15620/15621/15630/15631/15640/15641 for CEN5944 Add SVID3858 for BBBUG-1671 Rev3.5 (bonder version 466) Add ECID1592/1593 for CEN6229 Add ALID6666/6667/6668/6669/6670/6671/6672/6673 and CEID15660/15661/15670/15671/15680/15681/15690/15691/15700/15701/15710/15711/15720/15721/15730/15731 for CEN6253 Add SVID3859 for CEN6321 Add ALID6675 and CEID15750/15751 for CEN6368 Add ECID1069 for CEN6373 Add ECID1481/1482/1483/1484/1485/1486/1487/1488/1489/1490/1491/1492 and SVID3476/3477/3478/3479/3480/3481/3482 for CEN6646 Add CEID8210 – 8254 and SVID3120 – 3176 and ECID1162/1163/1164/1165 for CEN6516 Rev3.6 (bonder version 467) Update section1.1 Introduction to add SEMI support for E87/E40/E94 Add section4.11 Job Control to introduce new stream function Add ALID6676 and CEID15760/15761 for CEN6592 Add ECID1170/1171/1172 for CEN6813 Add SVID 3641 for BBBUG-3516 Add SVID3021/3022 and CEID8064/8065 for BBBUG-3274 Add ALID6680/6681/6682 and CEID15800/15801/15810/15811/15820/15821 for CEN6949 Add CEID8255/8256/8257/8258/8259/8260/15780/15781/15790/15791 and ALID6678/6679 And ECID1135/1136/1137 and SVID3177/3178/3179/3180/3181/3182/3183 for CEN6705 Add ECID1612/1613/1614/1615/1616/1617/1618/1619/1620/1621/1622/1623 for CEN7225 Add ECID1594/1595/1596/1597 and SVID3070/3071/3072/3073 and CEID8473/15840/15841 and ALID6684 for CEN6793 Add SVID3670/3671/3672/3673/3674/3675/3676/3677/3678/3679/3680 for CEN7372 Add CEID15830/15831 and ALID6683 for CEN6772 Add ECID1180/1181/1182 for CEN6827 Add ECID1528/1529 for CEN6785 Add CEID15860/15861 and ALID6686 for CEN6794 Add CEID15850/15851 and ALID6685 for BBBUG-5127 Add CEID15770/15771 and ALID6677 for CEN6498 Add CEID8354 for BBBUG-5197 Add ECID 1749/1750/1751/1752/1753/1754/1756/1757/1759/1760/1761/1762 and Page - 304 - of 321 Sep 18, 2020 Rev 4.1 Kulicke & Soffa™ SECS/GEM Interface for K&S Ball Bonders Bonder software version x-xx-x-472-series SVID3329/3368/3369/3370/3371/3372/3373/3374/3375/3376/3377/3378/3379/3380/3381/3382/3383 And CEID8070/15870/15871/15880/15881/15890/15891/15900/15901/15910/15911/15920/15921/15930/15931 And ALID6687/6688/6689/6690/6691/6692/6693 for CEN6832 Add ECID1250 for BBBUG-5533 Add introduction about new SEMIE87/E40/E49 support in section 1.1 Add new section 4.11 Job Control to introduce new stream functions defined by E5/E87/E40/E94 Update remote control command table in section 4.6 Update data set upload/download table in section 4.19 Page - 305 - of 321 Sep 18, 2020 Rev 4.1 Kulicke & Soffa™ SECS/GEM Interface for K&S Ball Bonders Bonder software version x-xx-x-472-series Rev3.7 (bonder version 468) Add ALID6694/6695 and CEID15940/15941/15950/15951 for CEN7877 Add ALID6726 and CEID16260/16261 for CEN8034 Add ALID6696/6697/6698/6699/6700/6701/6702/6703/6704 and CEID15960/15961/15970/15971/15980/15981/15990/15991/16000/16001/16010/16011/16020/16021/16030/16031 /16040/16041 for CEN6830 Add ALID6706 and CEID16060/16061 for BBBUG-5915 Add remote command INSPECTION_CONFIRM for CEN6832 Add ECID1755/1758/1763/1764/1765/1770/1771 and SVID3367/3384/3385/3386/3387/3388/3389/3390/3391/3392/3393/3394/3395/3396 and ALID6734 and CEID16340/16341 and remote command INSPECTION_PARA_INFO_SEND for CEN7411 Add ALID6705 and CEID8160/8161/8162/8163/8164/8165/16050/16051 for CEN7539 Add SVID3330/3331 for CEN7951 Add ALID6708/6709/6710/6711/6712/6713/6714/6715/6716/6717/6718/6719/6720/6722/6723/6724/6725 and CEID16080/16081/16090/16901/16100/16101/16110/16111/16120/16121/16130/16131/16140/16141/16150/16151 /16160/16161/16170/16171/16180/16181/16190/16191/16200/16201/16220/16221/16230/16231/16240/16241/162 50/16251 for CEN6892 Add ALID6707 and CEID16070/16071 for CEN7489 Add CEID8355 for CEN7827 Add CEID8080/8139 for CEN7541 Modify section 4.15 for AGV/OHT Auto Handling System Sequence support Hide some unused ALID and update some name Remove stream function for MMM only Update RCMD table Add Sample for S14F1/F2 in section 4.10 Remove section 10.5 Material Movement Management Rev3.8 (bonder version 469) Add ECID1329/1330/1331 for CEN8045 Add ALID6735 and CEID16350/16351 for CEN8069 Add ECID1138, SVID3190/3191 and CEID8267/8268 and RCMD RETRIEVE_CURRPP_LASTSAVED_TS for CEN7831 Add ALID6745/6746 and CEID16450/16451/16460/16461 for CEN8142 Add ECID1173/1174 and CEID8067 for CEN8189 Add SVID3070/3071 for CEN6793 Add ALID6351 and CEID12510/12511 for CEN8333 Add ECID8066 for CEN7052 Add ALID6736/6737/6738/6739/6740/6741/6742/6743/6744/6747/6748/6749/6750 and CEID8054/16360/16361/16370/16371/16380/16381/16390/16391/16400/16401/16410/16411/16420/16421/ 16430/16431/16440/16441/16470/16471/16480/16481/16490/16491/16500/16501 for CEN8014 Add ALID6752 and CEID16520/16521 for CEN8187 Delete CEID11140/11141/ALID6114 and rename CEID12130/12131/ALID6313 for BBBUG6819 Add ALID6751 and CEID16510/16511 for CEN8194 Add ECID1145/1146/1147/1148 and SVID3220/3221/3222/3223/3224/3225/3226/3227/3228/3229/3230/3231/3232/3233/3234/3235/3236/3237/3239 And CEID8375/8376/8377/8378/8379/8380/8381/8382/8383/8384/8385/8386/8387/8388/16270/16271/16280/16281/ 16290/16291/16300/16301/16310/16311/16320/16321/16330/16331 and ALID6727/6728/6729/6730/6731/6732/6733 and RCMD PART_PROCESSED_RSLT_CONFIRM/ CHANGE_OVER_REQUEST/ TOOL_CHANGE_CONFIRM/ WIRE_CHANGE_CONFIRM for CEN8071 Add section 10.5 appendix for Data Set Transfer Page - 306 - of 321 Sep 18, 2020 Rev 4.1 Kulicke & Soffa™ SECS/GEM Interface for K&S Ball Bonders Bonder software version x-xx-x-472-series Rev3.9 (bonder version 470) Add ECID1606/1607 for CEN8500 Add ECID1460/1461/1462 for CEN8665 Add ECID1149 and SVID3240/3241/3242/3243/3244/3245/3246 and CEID8489/8490/8491/8492/8493/8494/8495/8496/8497/8498/8490/8500/8501/8502 for CEN8701 Add ALID6753/6754 and CEID16530/16531/16540/16541 for CEN8682 Add ECID1470/1471 for CEN8748 Add SVID3247 and CEID8503 for BBBUG7178 Add SVID3700/3701/3702/3703/3704/3705/3706/3707/3708/3709/3710/3711/3712/3713/3714/3715 for CEN8777 Add ALID6757 and CEID16570/16571 for CEN7707 Add ECID1537/1538 and ALID6755/6756/6758 and CEID16550/16551/16560/16561/16580/16581 for CEN8778 Add ALID6759 and CEID16590/16591 for CEN8832 Add ECID1134 for BBBUG7276 Add ALID6760 and CEID16600/16601 for CEN8499 Add CEID8504/8505/8506/8507 for BBBUG7307 Rename ALID6706 and CEID16060/16061 for BBBUG7235 Update SVID3872/3873 to U4 type Add SVID3248/3249/3250 and CEID8497/8498 for BBBUG7746 Add CEID8508/8509 for BBBUG7747 Add ALID6765 and CEID16650/16651 for CEN9017/BBBUG7862 Add ALID6766 and CEID16660/16661 for BBBUG7532 Add ALID6761/6762/6763/6764 and CEID16610/16611/16620/16621/16630/16631/16640/16641 for BBBUG7689 Rev4.0 (bonder version 471) Add ALID6767/6768/6769/6770/6771/6772/6773/6774/6775/6776 and CEID16670/16671/16680/16681/16690/16691/16700/16701/16710/16711/16720/16721/16730/16731/16740/16741 /16750/16751/16760/16761 for CEN9325 Add ECID1175/1176 for CEN9349 Add SVID3332 and CEID8356 for CEN9326 Add ECID1186/1187/1188/1189/1190/1191 for CEN9385 Add ECID1177 and SVID3662/3663 for CEN9428 Add ALID6778/6779 and CEID16780/16781/16790/16791 for CEN9094 Add ALID6777 and CEID16770/16771 for CEN9150 Rev4.1 (bonder version 472) Add ALID6781 and CEID16810/16811/8120 and ECID1178/1179 for CEN9409 Add ALID6782/6783 and CEID16820/16821/16830/16831 for CEN9484 Add ECID1117 and ALID6785 and CEID16850/16851 for CEN9568 Add ALID6780 and CEID16800/16801 for CEN9272/CEN9380 Add ALID6784 and CEID16840/16841 for CEN9762 Add SVID3651 and ALID6790/6791/6792/6793 and CEID16900/16901/16910/16911/16920/16921/16930/16931 for CEN9636 Add ALID6787/6788/6789 and CEID16870/16871/16880/16881/16890/16891 for CEN9728 Add ALID6794 and CEID16940/16941 for BBBUG-8492 Add ECID1166/1167 for CEN9790 Add ECID1780/1781/1782/1783/1784/1785/1786/1787/1788/1789/1790/1791/1792/1793/1794/1795/1796/ 1797/1798 and SVID3880/3881/3882/3883/3884/3885/3886/3887/3888/3889/3890/3891/3892/3893/3894/3895/ 3896/3897/3898 and ALID6795 and CEID8510/8511/8512/16950/16951 and RCMD “RESET_PBI_WIRE_INSP_STATS” for CEN9636 phase2 Add ALID6799 and CEID16990/16991 for BBBUG-6444 Add ECID1255 for CEN9895 Update description of SVID3542 – 3565 PBI last unit statistics Please refer to respective bonder software version release notes for the complete list of software changes. Page - 307 - of 321 Sep 18, 2020 Rev 4.1 Kulicke & Soffa™ SECS/GEM Interface for K&S Ball Bonders Bonder software version x-xx-x-472-series 8. APPENDIX 4 - Summary of Document Changes None Page - 308 - of 321 Sep 18, 2020 Rev 4.1 Kulicke & Soffa™ SECS/GEM Interface for K&S Ball Bonders Bonder software version x-xx-x-472-series 9. APPENDIX 5 – Known Issues None 10. APPENDIX 6 – Sample Transactions and Scenarios 10.1 Communications Enable Communications * Received S1F13 * From Session ID 0. Wait on. Sys bytes 0x38564ba3. <L [2] <A '8028'> * MDLN <A '223E11'> * SOFTREV > . * Sending S1F14 * From Session ID 0. Wait off. Sys bytes 0x38564ba3. <L [2] <B 00> * COMMACK <L [0] > > . Equipment Test for Host Online Equipment sends S1F1 to host * Received S1F1 * From Session ID 0. Wait on. Sys bytes 0x38564ba6. * Sending S1F2 * From Session ID 0. Wait off. Sys bytes 0x38564ba6. <L [0] > . Equipment informs host of Control State Change to Online Remote * Received S6F11 * From Session ID 0. Wait off. Sys bytes 0x38564ba7. <L [3] <U2 0> <U2 8002> * Control State Changed To Online Remote <L [1] <L [2] <U2 1> * Linked Report ID <L [2] <A '1999121516085000'> <B 05> > > > > . 10.2 Alarms Enable All Alarms * Sending S5F3 Page - 309 - of 321 Sep 18, 2020 Rev 4.1 Kulicke & Soffa™ SECS/GEM Interface for K&S Ball Bonders Bonder software version x-xx-x-472-series * From Session ID 0. Wait on. Sys bytes 0x000001bb. <L [2] <B 80> * ALED <U2> * ALID > . * Received S5F4 * From Session ID 0. Wait off. Sys bytes 0x000001bb. <B 00> . Equipment Generated Alarm * Received S5F1 * From Session ID 0. Wait on. Sys bytes 0x38564bb2. <L [3] <B 85> <U2 6197>> * Output barcode read alarm <A 'MHS_OUT_BCR_FAIL' > . * Sending S5F2 * From Session ID 0. Wait off. Sys bytes 0x38564bb2. <B 00> . 10.3 Collection Events and Reports Disable All Collection Events * Sending S2F37 * From Session ID 0. Wait on. Sys bytes 0x000001bc. <L [2] <BOOL F> <L [0] > > . * Received S2F38 * From Session ID 0. Wait off. Sys bytes 0x000001bc. <B 00> . Delete All Reports * Sending S2F33 * From Session ID 0. Wait on. Sys bytes 0x000001bd. <L [2] <U2 0> <L [0] > > . * Received S2F34 * From Session ID 0. Wait off. Sys bytes 0x000001bd. <B 00> . Delete Specific Reports * Sending S2F33 * From Session ID 0. Wait on. Sys bytes 0x000001d4. Page - 310 - of 321 Sep 18, 2020 Rev 4.1 Kulicke & Soffa™ SECS/GEM Interface for K&S Ball Bonders Bonder software version x-xx-x-472-series <L [2] <U2 0> <L [7] <L [2] <U2 1> <L [0] > > <L [2] <U2 4> <L [0] > > <L [2] <U2 5> <L [0] > > <L [2] <U2 7> <L [0] > > <L [2] <U2 8> <L [0] > > <L [2] <U2 9> <L [0] > > <L [2] <U2 10> <L [0] > > > > * Report ID * Report ID * Report ID * Report ID * Report ID * Report ID * Report ID . * Received S2F34 * From Session ID 0. Wait off. Sys bytes 0x000001d4. <B 00> . Unlink All Reports Linked to Specific Collection Events * Sending S2F35 * From Session ID 0. Wait on. Sys bytes 0x000001de. <L [2] <U2 0> <L [15] <L [2] <U2 8003> * Control State Changed To Offline <L [0] > > Page - 311 - of 321 Sep 18, 2020 Rev 4.1 Kulicke & Soffa™ SECS/GEM Interface for K&S Ball Bonders Bonder software version x-xx-x-472-series <L [2] <U2 8001> <L [0] > > <L [2] <U2 8002> <L [0] > > <L [2] <U2 8004> <L [0] > > <L [2] <U2 8011> <L [0] > > <L [2] <U2 8103> <L [0] > > <L [2] <U2 8300> <L [0] > > <L [2] <U2 8302> <L [0] > > <L [2] <U2 8301> <L [0] > > <L [2] <U2 8303> <L [0] > > <L [2] <U2 8311> <L [0] > > <L [2] <U2 8312> <L [0] > > <L [2] <U2 8313> * Control State Changed To Online-Local * Control State Changed To Online-Remote * Process State Change * Operator EC Change * PP Select OK * MHS_MAG_IN_READY * MHS_MAG_IN_UNLOAD * MHS_MAG_OUT_ READY * MHS_MAG_OUT_UNLOAD * CE_IN_LOAD_PORT_STATE_CHG * CE_IN_UNLOAD_PORT_STATE_CHG * CE_OUT_LOAD_PORT_STATE_CHG Page - 312 - of 321 Sep 18, 2020 Rev 4.1 Kulicke & Soffa™ SECS/GEM Interface for K&S Ball Bonders Bonder software version x-xx-x-472-series <L [0] > > <L [2] <U2 8314> <L [0] > > <L [2] <U2 8010> <L [0] > > > > * CE_OUT_UNLOAD_PORT_STATE_CHG * MHS_MAG_OUT_BCR_REJECT . * Received S2F36 * From Session ID 0. Wait off. Sys bytes 0x000001de. <B 00> . Define Reports * Sending S2F33 * From Session ID 0. Wait on. Sys bytes 0x000001e8. <L [2] <U2 0> <L [7] <L [2] <U2 1> * Report ID <L [2] <U2 3011> * Clock <U2 3002> * ControlState > > <L [2] <U2 4> * Report ID <L [3] <U2 3011> * Clock <U2 3007> * ProcessState <U2 3008> * PreviousProcessState > > <L [2] <U2 5> * Report ID <L [1] <U2 10003> * ChangedEC > > <L [2] <U2 7> * Report ID <L [1] <U2 3004> * PPExecName > > <L [2] <U2 8> * Report ID Page - 313 - of 321 Sep 18, 2020 Rev 4.1 Kulicke & Soffa™ SECS/GEM Interface for K&S Ball Bonders Bonder software version x-xx-x-472-series <L [2] <U2 <U2 > > <L [2] <U2 <L [4] <U2 <U2 <U2 <U2 > > <L [2] <U2 <L [1] <U2 > > > > 3304> * InputBarCode 3305> 9> * Report ID 3035> 3036> 3037> 3038> 10> * InLoadPortState * InUnloadPortState * OutLoadPortState * OutUnloadPortState * Report ID 3011> * Clock . * Received S2F34 * From Session ID 0. Wait off. Sys bytes 0x000001e8. <B 00> . Link Reports to Collection Events * Sending S2F35 * From Session ID 0. Wait on. Sys bytes 0x000001f2. <L [2] <U2 0> <L [15] <L [2] <U2 8003> * Control State changed To Offline <L [1] <U2 1> * Report ID > > <L [2] <U2 8001> * Control State changed To Online-Local <L [1] <U2 1> * Report ID > > <L [2] <U2 8002> * Control State changed To Online-Remote <L [1] <U2 1> * Report ID > > <L [2] <U2 8004> * Process State Change <L [1] <U2 4> * Report ID > Page - 314 - of 321 Sep 18, 2020 Rev 4.1 Kulicke & Soffa™ SECS/GEM Interface for K&S Ball Bonders Bonder software version x-xx-x-472-series > <L [2] <U2 8011> * Operator EC Change <L [1] <U2 5> * Report ID > > <L [2] <U2 8103> * PP Select OK <L [1] <U2 7> * Report ID > > <L [2] <U2 8300> * MHS_MAG_IN_READY <L [1] <U2 8> * Report ID > > <L [2] <U2 8302> * MHS_MAG_INB_UNLOAD <L [1] <U2 8> * Report ID > > <L [2] <U2 8301> * MHS_MAG_OUT_READY <L [1] <U2 8> * Report ID > > <L [2] <U2 8303> * MHS_MAG_OUT_UNLOAD <L [1] <U2 8> * Report ID > > <L [2] <U2 8311> * CE_IN_LOAD_PORT_STATE_CHG <L [1] <U2 9> * Report ID > > <L [2] <U2 8312> * CE_IN_UNLOAD_PORT_STATE_CHG <L [1] <U2 9> * Report ID > > <L [2] <U2 8313> * CE_OUT_LOAD_PORT_STATE_CHG <L [1] <U2 9> * Report ID > > <L [2] <U2 8314> * CE_OUT_UNLOAD_PORT_STATE_CHG Page - 315 - of 321 Sep 18, 2020 Rev 4.1 Kulicke & Soffa™ SECS/GEM Interface for K&S Ball Bonders Bonder software version x-xx-x-472-series <L [1] <U2 9> * Report ID > > <L [2] <U2 8010> * TerminalMsgAck <L [1] <U2 10> * Report ID > > > > . * Received S2F36 * From Session ID 0. Wait off. Sys bytes 0x000001f2. <B 00> . Enable Specific Collection Events * Sending S2F37 * From Session ID 0. Wait on. Sys bytes 0x000001f8. <L [2] <BOOL T> <L [15] <U2 8003> * Control State changed to Offline <U2 8001> * Control State changed to Online-Local <U2 8002> * Control State changed to Online-Remote <U2 8004> * Process State Change <U2 8011> * Operator EC Change <U2 8103> * PP Select OK <U2 8300> * MHS_MAG_IN_READY <U2 8302> * MHS_MAG_IN_UNLOAD <U2 8301> * MHS_MAG_OUT_READY <U2 8303> * MHS_MAG_OUT_UNLOAD <U2 8311> * CE_IN_LOAD_PORT_STATE_CHG <U2 8312> * CE_IN_UNLOAD_PORT_STATE_CHG <U2 8313> * CE_OUT_LOAD_PORT_STATE_CHG <U2 8314> * CE_OUT_UNLOAD_PORT_STATE_CHG <U2 8010> * TerminalMsgAck > > . * Received S2F38 * From Session ID 0. Wait off. Sys bytes 0x000001f8. <B 00> . 10.4 Equipment Status Host Request for Selected Status Variable Values * Sending S1F3 * From Session ID 0. Wait on. Sys bytes 0x0000020c. <L [10] <U2 3011> * Clock <U2 3002> * ControlState <U2 3007> * ProcessState <U2 3035> * InLoadPortState <U2 3036> * InUnloadPortState Page - 316 - of 321 Sep 18, 2020 Rev 4.1 Kulicke & Soffa™ SECS/GEM Interface for K&S Ball Bonders Bonder software version x-xx-x-472-series <U2 <U2 <U2 <U2 <U2 > 3037> 3038> 3004> 3304> 3305> * OutLoadPortState * OutUnloadPortState * PPExecName * Input Bar Code * Output Bar Code . * Received S1F4 * From Session ID 0. Wait off. Sys bytes 0x0000020c. <L [10] <A '1999121516135600'> <B 05> <U1 1> <U2 0> <U2 0> <U2 1> <U2 1> <A 'GENERIC.BND'> <A ''> <A ''> > . Event Report From Equipment * Received S6F11 * From Session ID 0. Wait off. Sys bytes 0x38564bb3. <L [3] <U2 0> <U2 8004> * Process State Change <L [1] <L [2] <U2 4> * Report ID <L [3] <A '1999121516170800'> * Clock <U1 3> * ProcessState (Assist) <U1 2> * PreviousProcessState (Auto Run) > > > > . 10.5 Data Set Transfer Open Data Set To Upload File Sample: upload error.log file to host Page - 317 - of 321 Sep 18, 2020 Rev 4.1 Kulicke & Soffa™ SECS/GEM Interface for K&S Ball Bonders Bonder software version x-xx-x-472-series Host <ECID - SET the filename> S2F15 (Host)(29 bytes) -- Header: ( 00 00 82 0F 00 00 00 00 00 0F ) ---<L [1] ------<L [2] ---------<U2[1] 1563> ---------<A [9] error.log> ------> ---> Equipment <Acknowledge> S2F16 (WB)(13 bytes) -- Header: ( 00 00 02 10 00 00 00 00 00 0F ) ---<B [1] 0> <Open Data Set Request> S13F3 (Host)(43 bytes) -- Header: ( 00 00 8D 03 00 00 00 00 00 11 ) ---<L [3] ------<U2[1] 24201> ------<A [19] INDIVIDUAL_LOG_FILE> ------<U4[1] <Open Data Set Data> S13F4 (WB)(50 bytes) -- Header: ( 00 00 0D 04 00 00 00 00 00 11 ) ---<L [5] ------<U2[1] 24201> ------<A [19] INDIVIDUAL_LOG_FILE> ------<B [1] 0> ------<U2[1] 0> ------<U4[1] 0> ---> <Read Data Set Request> S13F5 (Host)(22 bytes) -- Header: ( 00 00 8D 05 00 00 00 00 00 12 ) ---<L [2] ------<U2[1] 24201> ------<U4[1] 0> ---> <Read Data set Data – error.log > S13F6 (WB)(16621 bytes) -- Header: ( 00 00 0D 06 00 00 00 00 00 12 ) ---<L [4] ------<U2[1] 24201> ------<B [1] 0> ------<U4[1] 0> ------<L [1] ---------<B [16591] 23 23 0A 42 4F 4E 44 45 52 20 52 45 42 4F 4F 54 45 44 0A 4C 4F 47 20 43 52 45 41 54 45 44 3A 20 4D 4F 4E 20 41 55 47 20 30 35 20 31 37 3A 33 33 3A 33 33 20 32 30 31 39 20 33 34 39 0A 23 23 0A 3C 35 30 3E 20 4F 50 5F 41 53 53 49 53 54 5F 43 4F 4D 50 4C 45 54 45 0A 4D 4F 4E 20 41 55 47 20 30 35 20 31 37 3A 33 34 3A 34 30 20 32 30 31 39 20 36 36 20 20 20 3C 78 31 37 63 33 66 3E 0A 5B 31 31 33 30 5D 0A 23 23 0A 42 4F 4E 44 45 52 20 52 45 42 4F 4F 54 45 44 0A 4C 4F 47 20 41 50 50 > Remainder of file truncated ------> Page - 318 - of 321 Sep 18, 2020 Rev 4.1 Kulicke & Soffa™ SECS/GEM Interface for K&S Ball Bonders Bonder software version x-xx-x-472-series <Read Data Set Request> S13F5 (PC)(22 bytes) -- Header: ( 00 00 8D 05 00 00 00 00 00 13 ) ---<L [2] ------<U2[1] 24201> ------<U4[1] 0> ---> <Read Data Set Data> S13F6 (WB)(27 bytes) -- Header: ( 00 00 0D 06 00 00 00 00 00 13 ) ---<L [4] ------<U2[1] 24201> ------<B [1] 8> ------<U4[1] -1> ------<L [0]> ---> <Close Data Set Send> S13F7 (PC)(16 bytes) -- Header: ( 00 00 8D 07 00 00 00 00 00 14 ) ---<L [1] ------<U2[1] 24201> ---> <Close Data Set ACK> S13F8 (WB)(19 bytes) -- Header: ( 00 00 0D 08 00 00 00 00 00 14 ) ---<L [2] ------<U2[1] 24201> ------<B [1] 0> ---> Open Data Set to Download File Sample: Download DEFECTID.txt file to bonder Host Equipment < Send Data Set> S13F1 (Host) (28 bytes) -- Header: ( 00 00 8D 01 00 00 00 00 00 05 ) ---<L [1] ------<A [14] DEFECT_ID_FILE> ---> < Send Data Set ACK> S13F2 (WB)(29 bytes) -- Header: ( 00 00 0D 02 00 00 00 00 00 05 ) ---<A [14] DEFECT_ID_FILE> ---<B [1] 0> <Open Data Set> S13F3 (WB)(38 bytes) -- Header: ( 00 00 0D 03 00 00 83 FD 63 5D ) ---<L [3] ------<U2[1] 12> ------<A [14] DEFECT_ID_FILE> ------<U4[1] 0> ---> <Open Data Set ACK> S13F4 (Host)(45 bytes) -- Header: ( 00 00 0D 04 00 00 83 FD 63 5D ) ---<L [5] ------<U2[1] 12> ------<A [14] DEFECT_ID_FILE> Page - 319 - of 321 Sep 18, 2020 Rev 4.1 Kulicke & Soffa™ SECS/GEM Interface for K&S Ball Bonders Bonder software version x-xx-x-472-series ------<B [1] 0> ------<U2[1] 0> ------<U4[1] 0> ---> <Read Data Set> S13F5 (WB)(22 bytes) -- Header: ( 00 00 0D 05 00 00 84 FD 63 5D ) ---<L [2] ------<U2[1] 12> ------<U4[1] 130102876> ---> <Read Data Set ACK> S13F6 (Host)(30 bytes) -- Header: ( 00 00 0D 06 00 00 84 FD 63 5D ) ---<L [4] ------<U2[1] 12> ------<B [1] 0> ------<U4[1] 0> ------<L [1] ---------<B [282] 31 31 20 4B 4E 53 5F 4F 55 54 50 55 54 5F 47 4F 4F 44 0D 0A 32 32 20 4B 4E 53 5F 49 4E 50 55 54 5F 44 45 46 45 43 54 0D 0A 33 33 20 4B 4E 53 5F 52 45 4A 45 43 54 5F 44 46 4C 54 0D 0A 34 34 20 4B 4E 53 5F 4E 4F 54 5F 42 4F 4E 44 45 44 0D 0A 31 32 20 4C 4C 41 56 20 2D 20 4C 42 20 4F 4E 20 4C 45 41 44 20 41 54 20 56 45 52 54 49 43 41 4C 0D 0A 37 33 20 4C 4C 41 46 20 2D 20 4C 42 20 4F 4E 20 4C 45 41 44 20 41 54 20 46 45 4E 43 45 0D 0A 37 34 20 42 57 41 56 20 2D 20 42 4F 4E 44 45 Remainder of file truncated> ------> ---> ---- Sent bytes 1 to 282 of 282 bytes total <Read Data Set> S13F5 (WB)(22 bytes) -- Header: ( 00 00 0D 05 00 00 85 FD 63 5D ) ---<L [2] ------<U2[1] 12> ------<U4[1] 130102876> ---> <Read Data Set ACK> S13F6 (Host)(27 bytes) -- Header: ( 00 00 0D 06 00 00 85 FD 63 5D ) ---<L [4] ------<U2[1] 12> ------<B [1] 8> ------<U4[1] 0> ------<L [0]> ---> ---- Sent EOF Page - 320 - of 321 Sep 18, 2020 Rev 4.1 Kulicke & Soffa™ SECS/GEM Interface for K&S Ball Bonders Bonder software version x-xx-x-472-series <Close Data Set> S13F7 (WB)(16 bytes) -- Header: ( 00 00 0D 07 00 00 86 FD 63 5D ) ---<L [1] ------<U2[1] ---> <Close Data Set ACK> S13F8 (Host)(19 bytes) -- Header: ( 00 00 0D 08 00 00 86 FD 63 5D ) ---<L [2] ------<U2[1] 12> ------<B [1] 0> ---> Page - 321 - of 321 Sep 18, 2020 Rev 4.1 Kulicke & Soffa™ 12>