11/22/21, 5:22 PM https://emcservice--c.visualforce.com/apex/KB_BreakFix_Printable?id=kA2f1000000X3VfCAK Select Your Audiences Level 40 = Employees and Partners Employee and Partner View Knowledge Base Article: 000499557 VMAX3, VMAX All Flash & PowerMax: Error code: 10.04F2.41 - MM has bad cable(000499557) Primary Product VMAX3 Series Product VMAX3 Series,VMAX All Flash,PowerMax Version: 12 Article Type: Break Fix Audience: Level 40 = Employees and Partners Last Published: Sun Sep 01 17:25:00 GMT 2019 Summary: Issue: Error code: 10.04F2.41 Error code: 04F2.41 EthMon: Engine:x Slot:Y Ping data check failed for Instances on slot: Z Subnet:W Cable Status:15 ErrCode:1 ErrStr:Port Speed Error Cause: Possible ethernet cabling issues to Subnet A or B. Resolution: Field Support: Issue C1,ETH,TACT to get state of Ethernet cabling. Confirm Port speed using C1,ETH,LINK, all should be reporting a good state and running at a speed of 1000 (NOTE: port 4 is optional depending on if eNAS or eMGMT containers are installed and in use). With regards to Directors 1 and 2: expect ports 3 & 5 to be in a good state. With regards to other Directors: expect port 3 to be in a good state (port 4 is unused). If all clean and environmental health check clean, then issue is recovered. However, if there is a history of these errors dialing home, and/or logging along-side 04F2.36 .37 or .38, then contact Support and refer to article VMAX3, VMAX All Flash & PowerMax: Error Code: 04F2.36/37/38. Primary Product: VMAX3 Series Product: VMAX3 Series,VMAX All Flash,PowerMax https://emcservice--c.visualforce.com/apex/KB_BreakFix_Printable?id=kA2f1000000X3VfCAK 1/2 11/22/21, 5:22 PM https://emcservice--c.visualforce.com/apex/KB_BreakFix_Printable?id=kA2f1000000X3VfCAK Problem Code: Corrective Maintenance;EMC Firmware;EMC Hardware Error Code: 10.04F2.41, 04F2.41 https://emcservice--c.visualforce.com/apex/KB_BreakFix_Printable?id=kA2f1000000X3VfCAK 2/2