Uploaded by Alvin VI Lee

1.4 MVAJxxx DOCR0704 A EU

advertisement
EU Declaration of Conformity
EN
Declaration number
MVAJxxx_DOCR0704_A_EU
Name of the manufacturer
GE Grid Solutions
Address of the manufacturer
Address of authorised
representative
UK Grid Solutions Ltd, Redhill Business Park, Stafford, ST16 1WT, UK
UK Grid Solutions Ltd, Redhill Business Park, Stafford, ST16 1WT, UK
This declaration of conformity is issued under the sole responsibility of the manufacturer.
Product / model
Object of the declaration
MVAJ05x, MVAJ10x & MVAJ20x
High/Low Burden Tripping Relay
The object of the declaration described above is in conformity with the relevant Union
harmonisation legislation:
2014/30/EU
2014/35/EU
EMC Directive
Low Voltage Directive
February 26, 2014
February 26, 2014
References to the relevant harmonised standards used or references to the other technical
specifications in relation to which conformity is declared:
Document Name
Issue
EN 60255‐27
Measuring relays and protection equipment ‐ Part 27: Product
Safety requirements
EN 60255‐26 Electromagnetic compatibility ‐ Product standard for measuring
relays and protection equipment
s
control, and laboratory use. General requirements
Signed for and on behalf of:
Place and Date:
2014
2013
2010
Stafford, 8th April 2020
Name:
Simon Richards
Name:
Allen Millard
Function:
Grid Solutions, Senior Product Staff
Manager
Function:
Grid Solutions, Senior Engineering
Manager, Testing
Signature:
Signature:
Page 1 of 2
Page 2 of 2
Declaration number
MVAJxxx_DOCR0704_A_EU
Additional Information
Variants Order No.
MVAJ - High/Low Burden Tripping Relay
Number of Contacts
Five
Ten
Twenty
Contact Mechanism
Self Reset (5 & 10 Contacts Only!)
Self Reset (Delayed Approx 2.5s) (10 Contacts Only!)
Hand-Reset
Electrically-Reset
Hand & Electrically-Reset
Case
Size 2
Size 4
Size 2
Size 4
(5 & 10 Contacts Only!) - Blue/Grey livery
(20 Contacts Only!) - Blue/Grey livery
(5 & 10 Contacts Only!) - Grey/Grey livery
(20 Contacts Only!) - Grey/Grey livery
Flagging
Standard Hand - Reset Flag
Following Flag
MVAJ
0 5
1 0
2 0
1
2
3
4
5
J
L
R
T
A
B
Voltage (Nominal)
24/27 Volts
30/34 Volts
48/54 Volts
110/125 Volts
220/250 Volts
0
0
0
0
1
Contact Combinations
5 Contact Versions
5 Normally Open
4 Normally Open/ 1 Normally Closed
3 Normally Open/ 2 Normally Closed
2 Normally Open/ 3 Normally Closed
4 Normally Open/ 1 Normally Open - internally wired for RESET cut off (MVAJ054/5R*08** variants ONLY!)
2 Normally Open/ 2 Normally Closed/ 1 Normally Open - internally wired for RESET cut off (MVAJ054/5R*08** variants ONLY!)
1 Normally Open/ 3 Normally Closed/ 1 Normally Open - internally wired for RESET cut off (MVAJ054/5R*08** variants ONLY!)
3 Normally Open/ 1 Normally Closed/ 1 Normally Open - internally wired for RESET cut off (MVAJ054/5R*08** variants ONLY!)
10 Contact Versions
10 Normally Open
8 Normally Open/ 2 Normally Closed
6 Normally Open/ 4 Normally Closed (MVAJ101R*08** variants OR MVAJ103/4/5 ONLY!)
4 Normally Open/ 6 Normally Closed (MVAJ101R*08** variants OR MVAJ103/4/5 ONLY!)
2 Normally Open/ 8 Normally Closed ( Not MVAJ101/2 !)
20 Contact Versions
20 Normally Open
18 Normally Open/ 2 Normally Closed
16 Normally Open/ 4 Normally Closed
14 Normally Open/ 6 Normally Closed
12 Normally Open/ 8 Normally Closed
10 Normally Open/ 10 Normally Closed
8 Normally Open/ 12 Normally Closed
6 Normally Open/ 14 Normally Closed
4 Normally Open/ 16 Normally Closed
Issue
Factory Defined
0
2
5
8
0
0
0
0
0
9
9
9
9
0
1
2
3
1
2
3
4
0
0
0
0
0
0
2
4
6
8
0
0
0
0
0
1
1
1
1
0
2
4
6
8
0
2
4
6
*
Page 2 of 2
Download