CONTRACT DATA
Clause Reference
With respect
to section 3
Items marked “N/A” do not apply in this contract.
The Employer is
1.
Name : Govt. of Jharhkand through Engineer in Chief, DWSD Nepal House Doranda, Ranchi.
Address:DWSD Nepal House Doranda, Ranchi.
[Cl.1.1.]
Name of Employer’s Representative: Executive Engineer, D W & S DivisionAdityapur
2.
The Engineer is Executive Engineer, Drinking Water and Sanitation DivisionAdityapur
Name of Authorized Representative:
3.
The dispute review expert appointed by Engineer in Chief or the
administrative head of the said DWSD
Name --------
NA
[Cl. 1. 1]
--------------------------------------------------------
Address -----------------------------------------------------------------------------------4.
The Defects Liability Period is 365 days from the date of completion.
[Cl. 1. 1&35]
5.
The Start Date shall be 07 days for the date of issue of the Notice to
[Cl.1.1.]
Proceedwith the work.
6.
The Intended Completion Date for the whole of the Works is 27 months [Cl. 1.1,17&28]
months after start of work with the following milestones: [C1.2.2&49.1]
Physical works to be completed. Period from the start date
Milestone dates:
[C1.2.2&49.1]
Physical works to be completed. Period from the start date
7
Milestone 1 i.e. 15% (of whole work)
6 Months
Milestone 2 i.e. 45% (of whole work) months
13 Months
Milestone 3 i.e. 75 % ( of whole work) months
21 Months
Milestone 4 i.e. Full
27Months.
.The Site is located at village Potka rural area.
8.
[Cl. 1.1]
[Cl. 1.1] .
The name and identification number of the Contract isDWSD/Adityapur/PotkaRWSS/MVS-15/2022-23.
61
9.
The works consist of Distribution System ,E.S.R. , Raw Water rising main, Clear Water rising main
W.T.P. Distribution System ,E.S.R. , Raw Water rising main, Clear Water rising main ,W.T.P. Etc_
[Cl. 1.1]
The works shall, inter alia, include the following, as specified or as directed:
Clause Reference with respect tosection3
R.C.C. Gangway
30 metre length and 3.00 Meter Wide
Supplying & laying DI & HDPE Pipeline
(100 mm to 600 mm dia ) – 701503.00mts DI Pipeline &
HDPE Pipe 110 mm Dia – 156116.00 mts
E.S.R.
(i) 4.50 Lakh Litre capacity & 20 M Staging.
(ii) 5.40 Lakh Litre capacity & 24 M Staging.
(iii) 7.00 Lakh Litre capacity & 18 M Staging.
(iv) 10.15 Lakh Litre capacity & 24 M Staging.
(v) 6.50 Lakh Litre capacity & 24 M Staging.
(vi) 5.80 Lakh Litre capacity & 24 M Staging.
(vii) 7.60 Lakh Litre capacity & 24 M Staging.
(viii) 7.00 Lakh Litre capacity & 24 M Staging.
(ix) 6.20 Lakh Litre capacity & 24 M Staging.
GSR
18.10 Lakh Litre
R.C.C Intake Well
9.00 M Inner dia
Clear water Pump –C. F Pump-
73.39 LPS, discharge and 150 M Head -2 Nos.
93.98 LPS, discharge and 65 M Head -3 Nos.
At SUMP C F Pump-
97.38 LPS, discharge and 140 M Head – 2 Nos
45.30 LPS, discharge and 190 M Head – 3 Nos
Raw water Pump – V.T. Pump
130.68 LPS discharge and 60 M Head – 4 Nos.
Water Treatment Plant
22.60 MLD (Conventional)
One unit of
Staff Quarters
Two unit of
Pump House
Other items as required to fullfill all contractual obligations as per theBid documents.
62