CONTRACT DATA Clause Reference With respect to section 3 Items marked “N/A” do not apply in this contract. The Employer is 1. Name : Govt. of Jharhkand through Engineer in Chief, DWSD Nepal House Doranda, Ranchi. Address:DWSD Nepal House Doranda, Ranchi. [Cl.1.1.] Name of Employer’s Representative: Executive Engineer, D W & S DivisionAdityapur 2. The Engineer is Executive Engineer, Drinking Water and Sanitation DivisionAdityapur Name of Authorized Representative: 3. The dispute review expert appointed by Engineer in Chief or the administrative head of the said DWSD Name -------- NA [Cl. 1. 1] -------------------------------------------------------- Address -----------------------------------------------------------------------------------4. The Defects Liability Period is 365 days from the date of completion. [Cl. 1. 1&35] 5. The Start Date shall be 07 days for the date of issue of the Notice to [Cl.1.1.] Proceedwith the work. 6. The Intended Completion Date for the whole of the Works is 27 months [Cl. 1.1,17&28] months after start of work with the following milestones: [C1.2.2&49.1] Physical works to be completed. Period from the start date Milestone dates: [C1.2.2&49.1] Physical works to be completed. Period from the start date 7 Milestone 1 i.e. 15% (of whole work) 6 Months Milestone 2 i.e. 45% (of whole work) months 13 Months Milestone 3 i.e. 75 % ( of whole work) months 21 Months Milestone 4 i.e. Full 27Months. .The Site is located at village Potka rural area. 8. [Cl. 1.1] [Cl. 1.1] . The name and identification number of the Contract isDWSD/Adityapur/PotkaRWSS/MVS-15/2022-23. 61 9. The works consist of Distribution System ,E.S.R. , Raw Water rising main, Clear Water rising main W.T.P. Distribution System ,E.S.R. , Raw Water rising main, Clear Water rising main ,W.T.P. Etc_ [Cl. 1.1] The works shall, inter alia, include the following, as specified or as directed: Clause Reference with respect tosection3 R.C.C. Gangway 30 metre length and 3.00 Meter Wide Supplying & laying DI & HDPE Pipeline (100 mm to 600 mm dia ) – 701503.00mts DI Pipeline & HDPE Pipe 110 mm Dia – 156116.00 mts E.S.R. (i) 4.50 Lakh Litre capacity & 20 M Staging. (ii) 5.40 Lakh Litre capacity & 24 M Staging. (iii) 7.00 Lakh Litre capacity & 18 M Staging. (iv) 10.15 Lakh Litre capacity & 24 M Staging. (v) 6.50 Lakh Litre capacity & 24 M Staging. (vi) 5.80 Lakh Litre capacity & 24 M Staging. (vii) 7.60 Lakh Litre capacity & 24 M Staging. (viii) 7.00 Lakh Litre capacity & 24 M Staging. (ix) 6.20 Lakh Litre capacity & 24 M Staging. GSR 18.10 Lakh Litre R.C.C Intake Well 9.00 M Inner dia Clear water Pump –C. F Pump- 73.39 LPS, discharge and 150 M Head -2 Nos. 93.98 LPS, discharge and 65 M Head -3 Nos. At SUMP C F Pump- 97.38 LPS, discharge and 140 M Head – 2 Nos 45.30 LPS, discharge and 190 M Head – 3 Nos Raw water Pump – V.T. Pump 130.68 LPS discharge and 60 M Head – 4 Nos. Water Treatment Plant 22.60 MLD (Conventional) One unit of Staff Quarters Two unit of Pump House Other items as required to fullfill all contractual obligations as per theBid documents. 62