Uploaded by ifboubaker

STAND PIPE MANIFOLD

advertisement
Route de l' Aeroport, Irara,
BP 701 Grande Poste,
Hassi Messaoud
30500 Ouargla, Algerie.
Tel: 029 730441
Fax: 029 730442
SARL Tuboscope Algerie
MISCELLANEOUS INSPECTION REPORT
T.V.D Work Order No.: 426 71 26
Date of Inspection:
16.03.2023
Customer:
ENAFOR RIG59
Inspection Report No.: D1-2
Work Location:
ENAFOR HMD BASE.
Customer W.O. No.:
Specification:
API
DS1
Customer spec.
Inspection method:
Wet
Dry
Dye Penetrant
Equipment used:
UV light
No:
Extent:
AC yoke
No:
DC coil
No:
Other ASTM E 797 &RP 574
Edition: 2021
Other WALL THICKNESS SPOT CHECK (READING BY mm)
Other
No: EM 8462
WALL THICKNESS SPOT
Serial no:
Description:
019816024
STAND PIPE MANIFOLD
Results:
SUMMARY OF RESULTS
* 5" ELBOW , CROSS AND TEE NOMINAL THICKNESS 32,63mm -MINIMUM THICKNESS : 28.55 mm ( 87,5 %)
* LOW READING S 32,30mm : (LOSS THICK 0,33 mm 0,003 %) ACCEPTED
5" PIPE NOMINAL THICKNESS 19,05mm, MINIMUM THICKNESS 16.66mm (87,5%)
* LOW READING S 18,50mm : (LOSS THICK 1,83 mm 0, 018%) ACCEPTED
* 2"ELBOW, CROSS AND TEE NOMINAL THICKNESS 21.09 mm -MINIMUM THICKNESS 18.45 mm ( 87,5 %)
* LOW READING S 18.80 mm : (LOSS THICK 2.69 mm 0,026 %) ACCEPTED
2" PIPE NOMINAL THICKNESS 11.07mm, MINIMUM THICKNESS 9.68 mm (87,5%)
* LOW READING S 10.00 mm : (LOSS THICK 1,07 mm 0,010 %) ACCEPTED
Comments:
Copying of this report is only allowed by
permission of TVD representative
QAF 102 Rev. 0 Date: 01.01.2011
SD = Shoulder Damage
TD = Thread Damage
Assem Fathy
Dif Ridha/Tayaa-a
Supervisor
Inspector
TE = Thread Elongation
BW = Box Widening
CO = Corrosion
P = Pitting
W = Washout
C = Crack
M = Flatspot / Mash
RF = Refaced Connection
B.B = Bore Back
S.R.G= Stress Relief Groove
Route de l' Aeroport, Irara,
BP 701 Grande Poste,
Hassi Messaoud
30500 Ouargla, Algerie.
Tel: 029 730441
Fax: 029 730442
SARL Tubosope Algerie
MISCELLANEOUS INSPECTION REPORT
T.V.D Work Order No.: 426 71 26
Date of Inspection:
Customer:
ENAFOR RIG 59
Inspection Report No.: D1
Work Location:
ENAFOR HMD BASE.
Customer W.O. No.:
Specification:
API
DS1
Customer spec.
Inspection method:
Wet
Dry
Dye Penetrant
Equipment used:
UV light
No:
Extent:
AC yoke
No:
DC coil
No:
Description:
019816024
- 01 EA : STAND PIPE MANIFOLD
B
C
D 5''Pipe
E
F
G 5''TEE
H
I
J
5" Elbow
K
L
M
5''Pipe
34.00-34.29-33.90
34.10-34.30-33.80
34.20-34.22-33.50
18.78-18.50-19.09
O
33.87-33.88-33.70
Q
33.66-33.70-33.67
R
33.85-33.80-33.67
S 2" Elbow
20.30-19.84-19.55
T
19.70-19.77-19.80
20.40-20.32-20.35
19.02-18.84-19.11
19.00-18.80-19.10
X
19.10-18.85-19.03
Y5''Pipe
Z
19.10-19.18-19.15
AA
19.01-19.08-19.05
19.01-19.08-19.05
AB 2" Elbow
Other
No: EM 8462
18.94-18.90-18.88
19.00-18.98-18.97
18.96-18.94-18.95
32.55-32.87-32.30
33.10-33.09-33.10
32.50-32.80-32.40
P 5''CROSS
U
V 5''Pipe
W
Other WALL THICKNESS SPOT CHECK (READING BY mm)
34.30-33.90-33.87
34.20-33.30-32.30
34.40-33.32-32.90
18.90-18.60-18.79
18.68-18.60-19.19
N
Edition: 2021
WALL THICKNESS SPOT
Serial no:
A 5" Elbow
Other ASTM E 797 &RP 574
11.02.2023
19.06-18.98-19.08
AC
19.31-19.68-19.55
AD
19.87-20.10-19.34
Copying of this report is only allowed by
permission of TVD representative
Assem Fathy
Tayaa Abdallah / Dif Ridha
Supervisor
Inspector
QAF 097 Rev. 0 Date: 01.01.2011
SD = Shoulder Damage
TD = Thread Damage
TE = Thread Elongation
BW = Box Widening
CO = Corrosion
P = Pitting
W = Washout
C = Crack
M = Flatspot / Mash
RF = Refaced Connection
B.B = Bore Back
S.R.G= Stress Relief Groove
Route de l' Aeroport, Irara,
BP 701 Grande Poste,
Hassi Messaoud
30500 Ouargla, Algerie.
Tel: 029 730441
Fax: 029 730442
SARL Tubosope Algerie
MISCELLANEOUS INSPECTION REPORT
T.V.D Work Order No.: 426 71 26
Date of Inspection:
Customer:
ENAFOR RIG 59
Inspection Report No.: D2
Work Location:
ENAFOR HMD BASE.
Customer W.O. No.:
Specification:
API
DS1
Customer spec.
Inspection method:
Wet
Dry
Dye Penetrant
Equipment used:
UV light
No:
Extent:
AO 2''Pipe
AN
AM
AL 5''Pipe
AK
AJ
AI
Other
No: EM 8462
- 01 EA : STAND PIPE MANIFOLD
18.86-18.67-18.89
18.78-18.80-18.79
18.68-18.67-18.90
18.88-18.80-18.89
10.12-10.15-10.14
10.20-10.12-10.04
10.12-10.11-10.00
18.70-18.90-18.88
18.90-19.00-18.87
18.89-18.90-18.89
18.91-19.00-18.89
AS2''Pipe
10.43-1067-10.60
AT
10.39-10.41-10.45
10.38-10.40-10.51
AU
AV
Other WALL THICKNESS SPOT CHECK (READING BY mm)
Description:
019816024
AG
AF
AE
DC coil
No:
Edition: 2021
WALL THICKNESS SPOT
Serial no:
AH 5''Pipe
AC yoke
No:
Other ASTM E 797 &RP 574
11.02.2023
10.42-10.41-10.48
AP2''Pipe
10.37-10.04-10.13
AQ
AR
10.13-10.20-10.05
10.30-10.33-10.14
Copying of this report is only allowed by
permission of TVD representative
Assem Fathy
Tayaa Abdallah / Dif Ridha
Supervisor
Inspector
QAF 097 Rev. 0 Date: 01.01.2011
SD = Shoulder Damage
TD = Thread Damage
TE = Thread Elongation
BW = Box Widening
CO = Corrosion
P = Pitting
W = Washout
C = Crack
M = Flatspot / Mash
RF = Refaced Connection
B.B = Bore Back
S.R.G= Stress Relief Groove