Route de l' Aeroport, Irara, BP 701 Grande Poste, Hassi Messaoud 30500 Ouargla, Algerie. Tel: 029 730441 Fax: 029 730442 SARL Tuboscope Algerie MISCELLANEOUS INSPECTION REPORT T.V.D Work Order No.: 426 71 26 Date of Inspection: 16.03.2023 Customer: ENAFOR RIG59 Inspection Report No.: D1-2 Work Location: ENAFOR HMD BASE. Customer W.O. No.: Specification: API DS1 Customer spec. Inspection method: Wet Dry Dye Penetrant Equipment used: UV light No: Extent: AC yoke No: DC coil No: Other ASTM E 797 &RP 574 Edition: 2021 Other WALL THICKNESS SPOT CHECK (READING BY mm) Other No: EM 8462 WALL THICKNESS SPOT Serial no: Description: 019816024 STAND PIPE MANIFOLD Results: SUMMARY OF RESULTS * 5" ELBOW , CROSS AND TEE NOMINAL THICKNESS 32,63mm -MINIMUM THICKNESS : 28.55 mm ( 87,5 %) * LOW READING S 32,30mm : (LOSS THICK 0,33 mm 0,003 %) ACCEPTED 5" PIPE NOMINAL THICKNESS 19,05mm, MINIMUM THICKNESS 16.66mm (87,5%) * LOW READING S 18,50mm : (LOSS THICK 1,83 mm 0, 018%) ACCEPTED * 2"ELBOW, CROSS AND TEE NOMINAL THICKNESS 21.09 mm -MINIMUM THICKNESS 18.45 mm ( 87,5 %) * LOW READING S 18.80 mm : (LOSS THICK 2.69 mm 0,026 %) ACCEPTED 2" PIPE NOMINAL THICKNESS 11.07mm, MINIMUM THICKNESS 9.68 mm (87,5%) * LOW READING S 10.00 mm : (LOSS THICK 1,07 mm 0,010 %) ACCEPTED Comments: Copying of this report is only allowed by permission of TVD representative QAF 102 Rev. 0 Date: 01.01.2011 SD = Shoulder Damage TD = Thread Damage Assem Fathy Dif Ridha/Tayaa-a Supervisor Inspector TE = Thread Elongation BW = Box Widening CO = Corrosion P = Pitting W = Washout C = Crack M = Flatspot / Mash RF = Refaced Connection B.B = Bore Back S.R.G= Stress Relief Groove Route de l' Aeroport, Irara, BP 701 Grande Poste, Hassi Messaoud 30500 Ouargla, Algerie. Tel: 029 730441 Fax: 029 730442 SARL Tubosope Algerie MISCELLANEOUS INSPECTION REPORT T.V.D Work Order No.: 426 71 26 Date of Inspection: Customer: ENAFOR RIG 59 Inspection Report No.: D1 Work Location: ENAFOR HMD BASE. Customer W.O. No.: Specification: API DS1 Customer spec. Inspection method: Wet Dry Dye Penetrant Equipment used: UV light No: Extent: AC yoke No: DC coil No: Description: 019816024 - 01 EA : STAND PIPE MANIFOLD B C D 5''Pipe E F G 5''TEE H I J 5" Elbow K L M 5''Pipe 34.00-34.29-33.90 34.10-34.30-33.80 34.20-34.22-33.50 18.78-18.50-19.09 O 33.87-33.88-33.70 Q 33.66-33.70-33.67 R 33.85-33.80-33.67 S 2" Elbow 20.30-19.84-19.55 T 19.70-19.77-19.80 20.40-20.32-20.35 19.02-18.84-19.11 19.00-18.80-19.10 X 19.10-18.85-19.03 Y5''Pipe Z 19.10-19.18-19.15 AA 19.01-19.08-19.05 19.01-19.08-19.05 AB 2" Elbow Other No: EM 8462 18.94-18.90-18.88 19.00-18.98-18.97 18.96-18.94-18.95 32.55-32.87-32.30 33.10-33.09-33.10 32.50-32.80-32.40 P 5''CROSS U V 5''Pipe W Other WALL THICKNESS SPOT CHECK (READING BY mm) 34.30-33.90-33.87 34.20-33.30-32.30 34.40-33.32-32.90 18.90-18.60-18.79 18.68-18.60-19.19 N Edition: 2021 WALL THICKNESS SPOT Serial no: A 5" Elbow Other ASTM E 797 &RP 574 11.02.2023 19.06-18.98-19.08 AC 19.31-19.68-19.55 AD 19.87-20.10-19.34 Copying of this report is only allowed by permission of TVD representative Assem Fathy Tayaa Abdallah / Dif Ridha Supervisor Inspector QAF 097 Rev. 0 Date: 01.01.2011 SD = Shoulder Damage TD = Thread Damage TE = Thread Elongation BW = Box Widening CO = Corrosion P = Pitting W = Washout C = Crack M = Flatspot / Mash RF = Refaced Connection B.B = Bore Back S.R.G= Stress Relief Groove Route de l' Aeroport, Irara, BP 701 Grande Poste, Hassi Messaoud 30500 Ouargla, Algerie. Tel: 029 730441 Fax: 029 730442 SARL Tubosope Algerie MISCELLANEOUS INSPECTION REPORT T.V.D Work Order No.: 426 71 26 Date of Inspection: Customer: ENAFOR RIG 59 Inspection Report No.: D2 Work Location: ENAFOR HMD BASE. Customer W.O. No.: Specification: API DS1 Customer spec. Inspection method: Wet Dry Dye Penetrant Equipment used: UV light No: Extent: AO 2''Pipe AN AM AL 5''Pipe AK AJ AI Other No: EM 8462 - 01 EA : STAND PIPE MANIFOLD 18.86-18.67-18.89 18.78-18.80-18.79 18.68-18.67-18.90 18.88-18.80-18.89 10.12-10.15-10.14 10.20-10.12-10.04 10.12-10.11-10.00 18.70-18.90-18.88 18.90-19.00-18.87 18.89-18.90-18.89 18.91-19.00-18.89 AS2''Pipe 10.43-1067-10.60 AT 10.39-10.41-10.45 10.38-10.40-10.51 AU AV Other WALL THICKNESS SPOT CHECK (READING BY mm) Description: 019816024 AG AF AE DC coil No: Edition: 2021 WALL THICKNESS SPOT Serial no: AH 5''Pipe AC yoke No: Other ASTM E 797 &RP 574 11.02.2023 10.42-10.41-10.48 AP2''Pipe 10.37-10.04-10.13 AQ AR 10.13-10.20-10.05 10.30-10.33-10.14 Copying of this report is only allowed by permission of TVD representative Assem Fathy Tayaa Abdallah / Dif Ridha Supervisor Inspector QAF 097 Rev. 0 Date: 01.01.2011 SD = Shoulder Damage TD = Thread Damage TE = Thread Elongation BW = Box Widening CO = Corrosion P = Pitting W = Washout C = Crack M = Flatspot / Mash RF = Refaced Connection B.B = Bore Back S.R.G= Stress Relief Groove