S TA TE OF CON N ECTI CU T CO NN E C TI C UT S IT IN G CO UN C IL Ten Franklin Square, New Britain, CT 06051 Phone: (860) 827-2935 Fax: (860) 827-2950 E-Mail: siting.council@ct.gov Web Site: portal.ct.gov/csc VIA ELECTRONIC MAIL January 7, 2022 Eric Breun Transcend Wireless 10 Industrial Avenue, Suite 3 Mahwah, NJ 07430 ebreun@transcendwireless.com RE: TS-T-MOBILE-025-211006 – T-Mobile request for an order to approve tower sharing at an existing telecommunications facility located at 1325 Cheshire Street, Cheshire, Connecticut. Dear Mr. Breun: The Connecticut Siting Council (Council) is in receipt of your correspondence of January 7, 2022 submitted in response to the Council’s November 4, 2021 notification of an incomplete request for tower sharing with regard to the above-referenced matter. The submission renders the request for tower sharing complete and the Council will process the request in accordance with the Federal Communications Commission 60-day timeframe. Thank you for your attention and cooperation. Sincerely, Melanie A. Bachman Executive Director MAB/FOC/emr S:\EMS_TS\1_BYTOWN\Cheshire\CheshireSt\T-Mobile\ts-t-mobile-025-211006_responseandacknowledgement_CheshireSt.docx 10 INDUSTRIAL AVE, SUITE 3 MAHWAH NJ 07430 PHONE: 201.684.0055 FAX: 201.684.0066 January 6, 2021 Melanie A. Bachman Executive Director Connecticut Siting Council 10 Franklin Square New Britain, CT 06051 T-Mobile Northeast LLC – CTNH568A – Response to Incomplete Modification – TS-T-MOBILE-025-211006 Tower Share Application 1325 Cheshire Street Latitude- 41.53258889 Longitude- -72.87047222 Dear Ms. Bachman, This letter and attachments are submitted on behalf of T-Mobile Northeast LLC (“T-Mobile”). T-Mobile plans to install antennas and related equipment at the tower site located at 1325 Cheshire Street, Cheshire, Connecticut. T-Mobile will install six (6) 600/700/1900/2100/5G MHz antennas and six (6) RRUs at the 129’ level of the existing 199’ monopole tower. Three (3) hybrid cables will also be installed. T-Mobile’s equipment cabinets will be placed on a 10’ X 15’ concrete pad within the existing ground facility. Included are plans by American Tower (Colliers Engineering), dated September 1, 2021, depicting the planned changes and attached as Exhibit A. Also included is a structural analysis prepared by American Tower (CLS Engineering), dated July 30, 2021, confirming that the existing tower is structurally capable of supporting the proposed equipment. This is attached and detailed in Exhibit B. Please accept this letter as notification pursuant to Regulations of Connecticut State Agencies 16-50aa, of T-Mobile’s intent to share a telecommunications facility pursuant to R.C.S.A. 16-50j-88. In accordance with R.C.S.A., a copy of this letter is being sent to Sean Kimball, Town Manager of Cheshire, William Voelker, Town Planner, as well as the tower and property owner, American Tower Corporation. Please see the attached letter from American Tower Corporation authorizing the proposed shared use of this facility attached as Exhibit C. The planned modifications of the facility fall squarely within those activities explicitly provided for in R.C.S.A. 16-50j-89. 1. The proposed modification will not result in an increase in the height of the existing structure. The top of the monopole is 199’; T-Mobile’s proposed antennas will be located at a center line height of 129’. 2. The proposed modifications will not result in the increase of the site boundary as depicted on the attached site plan. 3. The proposed modifications will not increase noise levels at the facility by six decibels or more, or to levels that exceed local and state criteria. T-Mobile’s plans include the installation of an emergency back-up generator; noise associated with this installation is exempt from State and local noise standards. The incremental effect of the proposed changes will be negligible. 4. The operation of the proposed antennas will not increase radio frequency emissions at the facility to a level at or above the Federal Communications Commission safety standard. As indicated in the attached power density calculations, the combined site operations will result in a total power density of 22.35%, as evidenced by Exhibit D. Connecticut General Statutes 16-50aa indicates that the Council must approve the shared use of a telecommunications facility provided it finds the shared use is technically, legally, environmentally, and economically feasible and meets public safety concerns. As demonstrated in this letter, T-Mobile respectfully submits that the shared use of this facility satisfies these criteria. A. Technical Feasibility. The existing monopole has been deemed structurally capable of supporting TMobile’s proposed loading, with the tower modifications/reinforcements as detailed in the structural analysis. The structural analysis is included as Exhibit B. B. Legal Feasibility. As referenced above, C.G.S. 16-50aa has been authorized to issue orders approving the shared use of an existing tower such as this monopole in Cheshire. Under the authority granted to the Council, an order of the Council approving the requested shared use would permit T-Mobile to obtain a building permit for the proposed installation. Further, a Letter of Authorization is included as Exhibit C, authorizing T-Mobile to file this application for shared use. C. Environmental Feasibility. The proposed shared use of this facility would have minimal environmental impact. The installation of T-Mobile equipment at the 129’ level of the existing 199’ tower would have an insignificant visual impact on the area around the tower. T-Mobile’s ground equipment would be installed within the existing facility compound. T-Mobile’s shared use would therefore not cause any significant alteration in the physical or environmental characteristics of the existing site. Additionally, as evidenced by Exhibit D, the proposed antennas would not increase radio frequency emissions to a level at or above the Federal Communications Commission safety standard. D. Economic Feasibility. T-Mobile will be entering into an agreement with the owner of this facility to mutually agreeable terms. As previously mentioned, the Letter of Authorization has been provided by the owner to assist T-Mobile with this tower sharing application. E. Public Safety Concerns. As discussed above, the monopole is structurally capable of supporting TMobile’s proposed loading. T-Mobile is not aware of any public safety concerns relative to the proposed sharing of the existing monopole. T-Mobile’s intentions of providing new and improved wireless service through the shared use of this facility is expected to enhance the safety and welfare of local residents and individuals traveling through Cheshire and nearby the facility. Sincerely, Eric Breun Eric Breun Transcend Wireless 10 Industrial Ave., Suite 3 Mahwah, New Jersey ebreun@transcendwireless.com 201-658-7728 CC: Sean Kimball – Town Manager William Voelker – Town Planner American Tower Corporation ST E RE T SITE LOCATION SITE LOCATION www.colliersengineering.com Doing Business as C O N S U L T I N G MADISON 135 New Road Madison, CT 06443 Phone: 860.395.0055 ATC SITE NAME: CHESHIRE ATC SITE NUMBER: 208478 T-MOBILE SITE NAME: CTNH568A T-MOBILE SITE NUMBER:CTNH568A SITE ADDRESS: 1325 CHESHIRE STREET CHESHIRE, CT 06410 VICINITY MAP COLLIERS ENGINEERING & DESIGN CT, P.C. DOING BUSINESS AS MASER CONSULTING Copyright © 2022. Colliers Engineering & Design All Rights Reserved. This drawing and all the information contained herein is authorized for use only by the party for whom the services were contracted or to whom it is certified. This drawing may not be copied, reused, disclosed, distributed or relied upon for any other purpose without the express written consent of Colliers Engineering & Design. LOCATION MAP REV. DESCRIPTION A PRELIM BY DATE RMD 08/02/21 0 FOR CONSTRUCTION AMN 08/06/21 1 FOR CONSTRUCTION RMD 09/01/21 2 FOR CONSTRUCTION AMN 01/03/22 ATC SITE NUMBER: 208478 T-MOBILE COVERAGE STRATEGY COLOCATION PLAN 67E5A998E 6160 CONFIGURATION COMPLIANCE CODE PROJECT SUMMARY ALL WORK SHALL BE PERFORMED AND MATERIALS INSTALLED IN ACCORDANCE WITH THE CURRENT EDITIONS OF THE FOLLOWING CODES AS ADOPTED BY THE LOCAL GOVERNMENT AUTHORITIES. NOTHING IN THESE PLANS IS TO BE CONSTRUED TO PERMIT WORK NOT CONFORMING TO THESE CODES. SITE ADDRESS: 1. INTERNATIONAL BUILDING CODE (IBC) THE PROPOSED PROJECT INCLUDES INSTALLING EQUIPMENT CABINETS ON A PROPOSED CONCRETE PAD INSIDE A 10' X 15' GROUND SPACE WITHIN THE EXISTING COMPOUND, AND INSTALLING NEW EQUIPMENT AND MOUNTS ON THE EXISTING TOWER. CHESHIRE, CT 06410 COUNTY: NEW HAVEN GEOGRAPHIC COORDINATES: 2. NATIONAL ELECTRIC CODE (NEC) 4. CITY/COUNTY ORDINANCES LATITUDE: 41.53258889 LONGITUDE: -72.87047222 GROUND ELEVATION: -170' AMSL PROJECT NOTES 1. 2. 3. PROJECT TEAM 4. TOWER OWNER: UTILITY COMPANIES POWER COMPANY: ITRON PHONE: (203) 874-9381 TELEPHONE COMPANY: T-MOBILE PHONE: (800) 937-8997 AMERICAN TOWER 10 PRESIDENTIAL WAY WOBURN, MA 01801 APPLICANT: T-MOBILE ENGINEER: COLLIERS ENGINEERING & DESIGN CT, P.C. 135 NEW ROAD MADISON, CT 06443 PROJECT #: 21904211A PROPERTY OWNER: AMERICAN TOWER 116 HUNTINGTON AVE BOSTON, MA 02116 PLANNING / APPLICANT'S REPRESENTATIVE: THE DERNA GROUP 22431 ANTONIO PARKWAY SUITE B160-234 RANCHO SANTA MARGARITA, CA 92688 CONTACT: RACHEL BRUIN PHONE: (805) 215-9444 EMAIL: RBRUIN@DERNAGRP.COM CHESHIRE T-MOBILE SITE NAME: PROJECT DESCRIPTION 1325 CHESHIRE STREET 3. LOCAL BUILDING CODE ATC SITE NAME: 5. 6. THE FACILITY IS UNMANNED. A TECHNICIAN WILL VISIT THE SITE APPROXIMATELY ONCE A MONTH FOR ROUTINE INSPECTION AND MAINTENANCE. THE PROJECT WILL NOT RESULT IN ANY SIGNIFICANT LAND DISTURBANCE OR EFFECT OF STORM WATER DRAINAGE. NO SANITARY SEWER, POTABLE WATER OR TRASH DISPOSAL IS REQUIRED. HANDICAP ACCESS IS NOT REQUIRED. THE PROJECT DEPICTED IN THESE PLANS QUALIFIES AS AN ELIGIBLE FACILITIES REQUEST ENTITLED TO EXPEDITED REVIEW UNDER 47 U.S.C. § 1455(A) AS A MODIFICATION OF AN EXISTING WIRELESS TOWER THAT INVOLVES THE COLLOCATION, REMOVAL, AND/OR REPLACEMENT OF TRANSMISSION EQUIPMENT THAT IS NOT A SUBSTANTIAL CHANGE UNDER CFR § 1.61000 (B)(7). PROJECT LOCATION DIRECTIONS CTNH568A SHEET INDEX SHEET NO: DESCRIPTION: REV: DATE: BY: G-001 TITLE SHEET 2 01/03/22 RMD G-002 GENERAL NOTES 2 01/03/22 RMD C-001 OVERALL SITE PLAN 2 01/03/22 RMD C-101 DETAILED SITE PLAN 2 01/03/22 RMD C-201 TOWER ELEVATION 2 01/03/22 RMD C-401 ANTENNA INFORMATION & SCHEDULE 2 01/03/22 RMD C-501 MOUNT DETAILS 2 01/03/22 RMD C-502 CONSTRUCTION DETAILS 2 01/03/22 RMD C-503 CONSTRUCTION DETAILS 2 01/03/22 RMD E-101 GROUNDING DETAILS & ELECTRICAL SCHEMATIC 2 01/03/22 RMD E-501 GROUNDING DETAILS 2 01/03/22 RMD E-601 PANEL SCHEDULE 2 01/03/22 RMD R-601 SUPPLEMENTAL R-602 SUPPLEMENTAL R-603 SUPPLEMENTAL SITE ADDRESS: 1325 CHESHIRE STREET CHESHIRE, CT 06410 SEAL: Digitally signed by Eric Anderson Date: 2022.01.04 12:37:04-05'00' DATE DRAWN: 08/02/21 ATC JOB NO: 13704270_D3 R-604 SUPPLEMENTAL CUSTOMER ID: CTNH568A R-605 SUPPLEMENTAL CUSTOMER #: CTNH568A R-606 SUPPLEMENTAL R-607 SUPPLEMENTAL TITLE SHEET SHEET NUMBER: REVISION: G-001 2 Copyright © 2022 ATC IP LLC, All Rights Reserved. E IR SH E CH Engineering & Design 1. B. C. D. E. F. G. H. I. J. K. L. M. N. O. 3. PRIOR TO SUBMISSION OF BID, CONTRACTOR SHALL COORDINATE WITH T-MOBILE REP TO DETERMINE IF ANY PERMITS WILL BE OBTAINED BY CONTRACTOR. ALL REQUIRED PERMITS NOT OBTAINED BY T-MOBILE MUST BE OBTAINED, AND PAID FOR, BY THE CONTRACTOR. B. ALL WELDS SHALL BE INSPECTED VISUALLY. 25% OF WELDS SHALL BE INSPECTED WITH DYE PENETRANT OR MAGNETIC PARTICLE TO MEET THE ACCEPTANCE CRITERIA OF AWS D1.1. REPAIR ALL WELDS AS NECESSARY. 23. CONTRACTOR SHALL INSTALL ALL SITE SIGNAGE IN ACCORDANCE WITH T-MOBILE SPECIFICATIONS AND REQUIREMENTS. C. INSPECTION SHALL BE PERFORMED BY AN AWS CERTIFIED WELD INSPECTOR. 24. CONTRACTOR SHALL SUBMIT ALL SHOP DRAWINGS TO T-MOBILE FOR REVIEW AND APPROVAL PRIOR TO FABRICATION. D. IT IS THE CONTRACTORS RESPONSIBILITY TO PROVIDE BURNING/WELDING PERMITS AS REQUIRED BY LOCAL GOVERNING AUTHORITY AND IF REQUIRED SHALL HAVE FIRE DEPARTMENT DETAIL FOR ANY WELDING ACTIVITY. 25. ALL EQUIPMENT SHALL BE INSTALLED ACCORDING TO MANUFACTURER'S SPECIFICATIONS AND LOCATED ACCORDING TO T-MOBILE SPECIFICATIONS, AND AS SHOWN IN THESE PLANS. E. OWNER FURNISHED MATERIALS, T-MOBILE "THE COMPANY" WILL PROVIDE AND THE CONTRACTOR WILL INSTALL A. 2. 22. BTS EQUIPMENT FRAME (PLATFORM) AND ICEBRIDGE SHELTER (GROUND BUILD/CO-LOCATE ONLY) AC/TELCO INTERFACE BOX (PPC) ICE BRIDGE (CABLE TRAY WITH COVER) (GROUND BUILD/CO-LOCATE ONLY, GC TO FURNISH AND INSTALL FOR ROOFTOP INSTALLATION) TOWERS, MONOPOLES TOWER LIGHTING GENERATORS & LIQUID PROPANE TANK ANTENNA STANDARD BRACKETS, FRAMES AND PIPES FOR MOUNTING ANTENNAS (INSTALLED BY OTHERS) TRANSMISSION LINE TRANSMISSION LINE JUMPERS TRANSMISSION LINE CONNECTORS WITH WEATHERPROOFING KITS TRANSMISSION LINE GROUND KITS HANGERS HOISTING GRIPS BTS EQUIPMENT THE CONTRACTOR IS RESPONSIBLE TO PROVIDE ALL OTHER MATERIALS FOR THE COMPLETE INSTALLATION OF THE SITE INCLUDING, BUT NOT LIMITED TO, SUCH MATERIALS AS FENCING, STRUCTURAL STEEL SUPPORTING SUB-FRAME FOR PLATFORM, ROOFING LABOR AND MATERIALS, GROUNDING RINGS, GROUNDING WIRES, COPPER-CLAD OR XIT CHEMICAL GROUND ROD(S), BUSS BARS, TRANSFORMERS AND DISCONNECT SWITCHES WHERE APPLICABLE, TEMPORARY ELECTRICAL POWER, CONDUIT, LANDSCAPING COMPOUND STONE, CRANES, CORE DRILLING, SLEEPERS AND RUBBER MATTING, REBAR, CONCRETE CAISSONS, PADS AND/OR AUGER MOUNTS, MISCELLANEOUS FASTENERS, CABLE TRAYS, NON-STANDARD ANTENNA FRAMES AND ALL OTHER MATERIAL AND LABOR REQUIRED TO COMPLETE THE JOB ACCORDING TO THE DRAWINGS AND SPECIFICATIONS. IT IS THE POSITION OF T-MOBILE TO APPLY FOR PERMITTING AND CONTRACTOR RESPONSIBLE FOR PICKUP AND PAYMENT OF REQUIRED PERMITS. 26. 27. 28. 29. ALL WORK SHALL CONFORM TO ALL CURRENT APPLICABLE FEDERAL, STATE, AND LOCAL CODES, INCLUDING ANSI/EIA/TIA-222, AND COMPLY WITH ATC CONSTRUCTION SPECIFICATIONS. CONTRACTOR SHALL CONTACT LOCAL 811 FOR IDENTIFICATION OF UNDERGROUND UTILITIES PRIOR TO START OF CONSTRUCTION. 5. CONTRACTOR SHALL BE RESPONSIBLE FOR COORDINATING ALL REQUIRED INSPECTIONS. 6. ALL DIMENSIONS TO, OF, AND ON EXISTING BUILDINGS, DRAINAGE STRUCTURES, AND SITE IMPROVEMENTS SHALL BE VERIFIED IN FIELD BY CONTRACTOR WITH ALL DISCREPANCIES REPORTED TO THE ENGINEER. 7. DO NOT CHANGE SIZE OR SPACING OF STRUCTURAL ELEMENTS. 8. DETAILS SHOWN ARE TYPICAL; SIMILAR DETAILS APPLY TO SIMILAR CONDITIONS UNLESS OTHERWISE NOTED. 9. THESE DRAWINGS DO NOT INCLUDE NECESSARY COMPONENTS FOR CONSTRUCTION SAFETY WHICH SHALL BE THE SOLE RESPONSIBILITY OF THE CONTRACTOR. 31. 10. 32. 33. CONTRACTOR SHALL BRACE STRUCTURES UNTIL ALL STRUCTURAL ELEMENTS NEEDED FOR STABILITY ARE INSTALLED. THESE ELEMENTS ARE AS FOLLOWS: LATERAL BRACING, ANCHOR BOLTS, ETC. 11. CONTRACTOR SHALL DETERMINE EXACT LOCATION OF EXISTING UTILITIES, GROUNDS DRAINS, DRAIN PIPES, VENTS, ETC. BEFORE COMMENCING WORK. 12. INCORRECTLY FABRICATED, DAMAGED, OR OTHERWISE MISFITTING OR NONCONFORMING MATERIALS OR CONDITIONS SHALL BE REPORTED TO THE T-MOBILE REP PRIOR TO REMEDIAL OR CORRECTIVE ACTION. ANY SUCH REMEDIAL ACTION SHALL REQUIRE WRITTEN APPROVAL BY THE T-MOBILE REP PRIOR TO PROCEEDING. THE CONTRACTOR SHALL SUPERVISE AND DIRECT THE PROJECT DESCRIBED HEREIN. THE CONTRACTOR SHALL BE SOLELY RESPONSIBLE FOR ALL THE CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES AND PROCEDURES AND FOR COORDINATING ALL PORTIONS OF THE WORK UNDER THE CONTRACT. CONTRACTOR SHALL NOTIFY T-MOBILE REP A MINIMUM OF 48 HOURS IN ADVANCE OF POURING CONCRETE OR BACKFILLING ANY UNDERGROUND UTILITIES, FOUNDATIONS OR SEALING ANY WALL, FLOOR OR ROOF PENETRATIONS FOR ENGINEERING REVIEW AND APPROVAL. CONTRACTOR SHALL BE RESPONSIBLE FOR SITE SAFETY INCLUDING COMPLIANCE WITH ALL APPLICABLE OSHA STANDARDS AND RECOMMENDATIONS AND SHALL PROVIDE ALL NECESSARY SAFETY DEVICES INCLUDING PPE AND PPM AND CONSTRUCTION DEVICES SUCH AS WELDING AND FIRE PREVENTION, TEMPORARY SHORING, SCAFFOLDING, TRENCH BOXES/SLOPING, BARRIERS, ETC. THE CONTRACTOR SHALL PROTECT AT HIS OWN EXPENSE, ALL EXISTING FACILITIES AND SUCH OF HIS NEW WORK LIABLE TO INJURY DURING THE CONSTRUCTION PERIOD. ANY DAMAGE CAUSED BY NEGLECT ON THE PART OF THIS CONTRACTOR OR HIS REPRESENTATIVES, OR BY THE ELEMENTS DUE TO NEGLECT ON THE PART OF THIS CONTRACTOR OR HIS REPRESENTATIVES, EITHER TO THE EXISTING WORK, OR TO HIS WORK OR THE WORK OF ANY OTHER CONTRACTOR, SHALL BE REPAIRED AT HIS EXPENSE TO THE OWNER'S SATISFACTION. I. 1. 13. 14. EACH CONTRACTOR SHALL COOPERATE WITH THE T-MOBILE REP, AND COORDINATE HIS WORK WITH THE WORK OF OTHERS. CONTRACTOR SHALL REPAIR ANY DAMAGE CAUSED BY CONSTRUCTION OF THIS PROJECT TO MATCH EXISTING PRE-CONSTRUCTION CONDITIONS TO THE SATISFACTION OF THE T-MOBILE CONSTRUCTION MANAGER. IN ORDER TO ESTABLISH STANDARDS OF QUALITY AND PERFORMANCE, ALL TYPES OF MATERIALS LISTED HEREINAFTER BY MANUFACTURER’S NAMES AND/OR MANUFACTURER’S CATALOG NUMBER SHALL BE PROVIDED BY THESE MANUFACTURERS AS SPECIFIED. T-MOBILE FURNISHED EQUIPMENT SHALL BE PICKED-UP AT THE T-MOBILE WAREHOUSE, NO LATER THAN 48HR AFTER BEING NOTIFIED INSURED, STORED, UNCRATE, PROTECTED AND INSTALLED BY THE CONTRACTOR WITH ALL APPURTENANCES REQUIRED TO PLACE THE EQUIPMENT IN OPERATION, READY FOR USE. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE EQUIPMENT AFTER PICKING IT UP. ALL CABLE/CONDUIT ENTRY/EXIT PORTS SHALL BE WEATHERPROOFED DURING INSTALLATION USING A SILICONE SEALANT. 16. WHERE EXISTING CONDITIONS DO NOT MATCH THOSE SHOWN IN THIS PLAN SET, CONTRACTOR SHALL NOTIFY THE T-MOBILE REP AND ENGINEER OF RECORD IMMEDIATELY. 17. 18. 19. CONTRACTOR SHALL ENSURE ALL SUBCONTRACTORS ARE PROVIDED WITH A COMPLETE AND CURRENT SET OF DRAWINGS AND SPECIFICATIONS FOR THIS PROJECT. CONTRACTOR SHALL REMOVE ALL RUBBISH AND DEBRIS FROM THE SITE AT THE END OF EACH DAY. 3. 4. CONTRACTOR SHALL COORDINATE WORK SCHEDULE WITH AMERICAN TOWER CORPORATION (ATC) AND TAKE PRECAUTIONS TO MINIMIZE IMPACT AND DISRUPTION OF OTHER OCCUPANTS OF THE FACILITY. 5. 20. CONTRACTOR SHALL FURNISH T-MOBILE AND AMERICAN TOWER CORPORATION (ATC) WITH A PDF MARKED UP AS-BUILT SET OF DRAWINGS UPON COMPLETION OF WORK. 6. 21. PRIOR TO SUBMISSION OF BID, CONTRACTOR SHALL COORDINATE WITH T-MOBILE REP TO DETERMINE WHAT, IF ANY, ITEMS WILL BE PROVIDED. ALL ITEMS NOT PROVIDED SHALL BE PROVIDED AND INSTALLED BY THE CONTRACTOR. CONTRACTOR WILL INSTALL ALL ITEMS PROVIDED. INSTALLATION OF CONCRETE EXPANSION/WEDGE ANCHOR SHALL BE PER MANUFACTURER'S WRITTEN RECOMMENDED PROCEDURE. THE ANCHOR BOLT, DOWEL, OR ROD SHALL CONFORM TO MANUFACTURER'S RECOMMENDATION FOR EMBEDMENT DEPTH OR AS SHOWN ON THE DRAWINGS. NO REBAR SHALL BE CUT WITHOUT PRIOR APPROVAL FROM AN ATC ENGINEER WHEN DRILLING HOLES IN CONCRETE. ALL ELECTRODES TO BE LOW HYDROGEN, MATCHING FILLER METAL, PER AWS D1.1, UNLESS NOTED OTHERWISE. 8. ADMIXTURES SHALL CONFORM TO THE APPROPRIATE ASTM STANDARD AS REFERENCED IN "METHOD 1" OF ACI 301. MINIMUM WELD SIZE TO BE 0.1875 INCH FILLET WELDS, UNLESS NOTED OTHERWISE. 9. DO NOT WELD OR TACK WELD REINFORCING STEEL. 10. ALL DOWELS, ANCHOR BOLTS, EMBEDDED STEEL, ELECTRICAL CONDUITS, PIPE SLEEVES, GROUNDS AND ALL OTHER EMBEDDED ITEMS AND FORMED DETAILS SHALL BE IN PLACE BEFORE START OF CONCRETE PLACEMENT. PRIOR TO FIELD WELDING GALVANIZING MATERIAL, CONTRACTOR SHALL GRIND OFF GALVANIZING ½” BEYOND ALL FIELD WELD SURFACES. AFTER WELD AND WELD INSPECTION IS COMPLETE, REPAIR ALL GROUND AND WELDED SURFACES WITH ZRC GALVILITE COLD GALVANIZING COMPOUND PER ASTM A780 AND MANUFACTURERS RECOMMENDATIONS. T-MOBILE OR HIS ARCHITECT/ENGINEER RESERVES THE RIGHT TO REJECT ANY EQUIPMENT OR MATERIALS WHICH, IN HIS OWN OPINION ARE NOT IN COMPLIANCE WITH THE CONTRACT DOCUMENTS, EITHER BEFORE OR AFTER INSTALLATION AND THE EQUIPMENT SHALL BE REPLACED WITH EQUIPMENT CONFORMING TO THE REQUIREMENTS OF THE CONTRACT DOCUMENTS BY THE CONTRACTOR AT NO COST TO T-MOBILE OR THEIR ARCHITECT/ENGINEER. THE CONTRACTOR SHALL PROVIDE ADEQUATE SHORING AND/OR BRACING WHERE REQUIRED DURING CONSTRUCTION UNTIL ALL CONNECTIONS ARE COMPLETE. 11. REINFORCEMENT SHALL BE COLD BENT WHENEVER BENDING IS REQUIRED. 12. DO NOT PLACE CONCRETE IN WATER, ICE, OR ON FROZEN GROUND. 13. FOR COLD-WEATHER (ACI 306) AND HOT-WEATHER (ACI 301M) CONCRETE PLACEMENT, CONFORM TO APPLICABLE ACI CODES AND RECOMMENDATIONS. IN EITHER CASE, MATERIALS CONTAINING CHLORIDE, CALCIUM, SALTS, ETC. SHALL NOT BE USED. PROTECT FRESH CONCRETE FROM WEATHER FOR 7 DAYS, MINIMUM. 14. ALL CONCRETE SHALL HAVE A "SMOOTH FORM FINISH." 15. SPLICING OF REINFORCEMENT IS PERMITTED ONLY AT LOCATIONS SHOWN IN THE CONTRACT DRAWINGS OR AS ACCEPTED BY THE ENGINEER. UNLESS OTHERWISE SHOWN OR NOTED REINFORCING STEEL SHALL BE SPLICED TO DEVELOP ITS FULL TENSILE CAPACITY (CLASS A) IN ACCORDANCE WITH ACI 318. ANY FIELD CHANGES OR SUBSTITUTIONS SHALL HAVE PRIOR APPROVAL FROM THE ENGINEER, AND T- MOBILE PROJECT MANAGER IN WRITING ANTENNA AND COAXIAL CABLES ARE FURNISHED BY T-MOBILE UNDER A SEPARATE CONTRACT. THE CONTRACTOR SHALL ASSIST ANTENNA INSTALLATION CONTRACTOR IN TERMS OD COORDINATION AND SITE ACCESS. ERECTION SUBCONTRACTOR SHALL BE RESPONSIBLE FOR THE PROTECTION OF PERSONNEL AND INSTALL ANTENNA AS INDICATE ON DRAWINGS AND T-MOBILE SPECIFICATIONS. C. INSTALL GALVANIZED STEEL ANTENNA MOUNTS AS INDICATED ON DRAWINGS D. INSTALL FURNISHED GALVANIZED STEEL OR ALUMINUM WAVEGUIDE AND PROVIDE PRINTOUT OF THAT TEST. E. CONTRACTOR SHALL PROVIDE FOUR (4) SETS OF SWEEP TESTS USING ANRITZU-PACKARD 8713B RF SCALAR NETWORK ANALYZER. SUBMIT FREQUENCY DOMAIN REFLECTOMETER(FDR) TESTS RESULTS TO THE PROJECT MANAGER. SWEEP TESTS SHALL BE AS PER ATTACHED RFS "MINIMUM FIELD TESTING RECOMMENDED FOR ANTENNA AND HELIAX COAXIAL CABLE SYSTEMS" DATED 10/5/93. TESTING SHALL BE PERFORMED BY AN INDEPENDENT TESTING SERVICE AND BE BOUND AND SUBMITTED WITHIN ONE WEEK OF WORK COMPLETION. 16. DETAILING OF REINFORCING STEEL SHALL CONFORM TO "ACI MANUAL OF STANDARD PRACTICE FOR DETAILING REINFORCED CONCRETE STRUCTURES" (ACI 315). 17. ALL SLAB CONSTRUCTION SHALL BE CAST MONOLITHICALLY WITHOUT HORIZONTAL CONSTRUCTION JOINTS, UNLESS SHOWN IN THE CONTRACT DRAWINGS. F. INSTALL COAXIAL CABLES AND TERMINATING BETWEEN ANTENNAS AND EQUIPMENT PER MANUFACTURER'S RECOMMENDATIONS. WEATHERPROOF ALL CONNECTIONS BETWEEN THE ANTENNA AND EQUIPMENT PER MANUFACTURER'S REQUIREMENTS. TERMINATE ALL COAXIAL CABLE THREE (3) FEET IN EXCESS OF ENTRY PORT LOCATION UNLESS OTHERWISE STATED. ANTENNA AND COAXIAL CABLE GROUNDING: 2. ALL EXTERIOR #6 GREED GROUND WIRE "DAISY CHAIN" CONNECTIONS ARE TO BE WEATHER SEALED WITH RFS CONNECTORS/SPLICE WEATHERPROOFING KIT #221213 OR EQUAL. ASTM A-572, GRADE 50 - ALL W SHAPES, UNLESS NOTED OR A992 OTHERWISE 3. ALL COAXIAL CABLE GROUNDING KITS ARE TO BE INSTALLED ON STRAIGHT RUNS OF COAXIAL CABLE (NOT WITHIN BENDS) B. ASTM A-36 - ALL OTHER ROLLED SHAPES, PLATES AND BARS UNLESS NOTED OTHERWISE. C. ASTM A-500, GRADE B - HSS SECTION (SQUARE, RECTANGULAR, AND ROUND) 18. LOCATION OF ALL CONSTRUCTION JOINTS ARE SUBJECT TO THE REQUIREMENTS OF THE CONTRACT DOCUMENTS, CONFORMANCE WITH ACI 318, AND ACCEPTANCE OF THE ENGINEER. DRAWINGS SHOWING LOCATION OF DETAILS OF THE PROPOSED CONSTRUCTION JOINTS SHALL BE SUBMITTED WITH REINFORCING STEEL PLACEMENT DRAWINGS. D. ASTM A-325, TYPE SC OR N MEMBERS E. ASTM F-1554 07 - ALL BOLTS FOR CONNECTING STRUCTURAL - ALL ANCHOR BOLTS, UNLESS NOTED OTHERWISE ALL EXPOSED STRUCTURAL STEEL MEMBERS SHALL BE HOT-DIPPED GALVANIZED AFTER FABRICATION PER ASTM A123. EXPOSED STEEL HARDWARE AND ANCHOR BOLTS SHALL BE GALVANIZED PER ASTM A153 OR B695. ALL FIELD CUT SURFACES, FIELD DRILLED HOLES AND GROUND SURFACES WHERE EXISTING PAINT OR GALVANIZATION REMOVAL WAS REQUIRED SHALL BE REPAIRED WITH (2) BRUSHED COATS OF ZRC GALVILITE COLD GALVANIZING COMPOUND PER ASTM A780 AND MANUFACTURER’S RECOMMENDATIONS. DO NOT DRILL HOLES THROUGH STRUCTURAL STEEL MEMBERS EXCEPT AS SHOWN AND DETAILED ON STRUCTURAL DRAWINGS. CONNECTIONS: 2. MIX DESIGN SHALL BE APPROVED BY T-MOBILE REP PRIOR TO PLACING CONCRETE. 3. CONCRETE SHALL BE NORMAL WEIGHT, 6 % AIR ENTRAINED (+/- 1.5%) WITH A SLUMP RANGE OF 3-6" AND HAVE A MINIMUM 28-DAY COMPRESSIVE STRENGTH OF 4000 PSI UNLESS OTHERWISE NOTED. 4. BAR SUPPORTS SHALL BE ALL-GALVANIZED METAL WITH PLASTIC TIPS. 21. ALL REINFORCEMENT SHALL BE SECURELY TIED IN PLACE TO PREVENT DISPLACEMENT BY CONSTRUCTION TRAFFIC OR CONCRETE. TIE WIRE SHALL BE OF SUFFICIENT STRENGTH FOR INTENDED PURPOSE, BUT NOT LESS THAN NO. 18 GAUGE. 22. SLAB ON GROUND: COMPACT STRUCTURAL FILL TO 95% DENSITY AND THEN PLACE 6" GRAVEL BENEATH SLAB. 1. ELECTRICAL DESIGN SHALL BE PERFORMED BY ELECTRICAL CONTRACTOR. STRUCTURAL DESIGN SHALL BE PERFORMED BY GENERAL CONTRACTOR. ELECTRICAL CONTRACTOR SHALL ENSURE THAT ALL WORK COMPLIES WITH ALL APPLICABLE LOCAL AND STATE CODES AND NATIONAL ELECTRICAL CODE. 2. ALL SUGGESTED ELECTRICAL ELEMENTS (SUCH AS BREAKER SIZES, WIRE SIZES, CONDUITS SIZES ARE FOR ZONING PURPOSES ONLY. IT IS THE RESPONSIBILITY TO OF THE ELECTRICAL CONTRACTOR TO CONFIRM COMPLIANCE WITH LOCAL ELECTRICAL CODES AND PASS ALL APPLICABLE AND NECESSARY INSPECTIONS. IN SOME EVENTS, IT MAY BE NECESSARY TO PERFORM AN ELECTRICAL LOAD STUDY TO VERIFY THE CAPACITY OF THE EXISTING SERVICE. THIS IS NOT THE RESPONSIBILITY OF CONCORDIA. IT IS THE RESPONSIBILITY OF THE ELECTRICAL CONTRACTOR. 3. CONTRACTOR SHALL FIELD LOCATE ALL BELOW GRADE GROUND LINES AND UTILITY LINES PRIOR TO CONSTRUCTION. CONTRACTOR IS RESPONSIBLE FOR RELOCATION OF ALL UTILITIES AND GROUND LINES THAT MAY BECOME DISTURBED OR CONFLICTING IN THE COURSE OF CONSTRUCTION. ASTM C150, TYPE 2 REINFORCEMENT: ASTM A185, PLAIN STEEL WELDED WIRE FABRIC REINFORCEMENT BARS: ASTM A615, GRADE 60, DEFORMED NORMAL WEIGHT AGGREGATE: ASTM C33 WATER: ASTM C 94/C 94M WELDED WIRE FABRIC: ASTM A185 ADMIXTURES: -WATER-REDUCING AGENT: A. ALL WELDING TO BE PERFORMED BY AWS CERTIFIED WELDERS AND CONDUCTED IN ACCORDANCE WITH THE LATEST EDITION OF THE AWS WELDING CODE D1.1. ASTM C 494/C 494M, TYPE A -AIR-ENTERING AGENT: ASTM C 260/C 260M -SUPERPLASTICIZER: ASTM C494, TYPE F OR TYPE G -RETARDING: ASTM C 494/C 494M, TYPE B Madison, CT 06443 Phone: 860.395.0055 COLLIERS ENGINEERING & DESIGN CT, P.C. DOING BUSINESS AS MASER CONSULTING Copyright © 2022. Colliers Engineering & Design All Rights Reserved. This drawing and all the information contained herein is authorized for use only by the party for whom the services were contracted or to whom it is certified. This drawing may not be copied, reused, disclosed, distributed or relied upon for any other purpose without the express written consent of Colliers Engineering & Design. REV. DESCRIPTION A PRELIM BY DATE RMD 08/02/21 0 FOR CONSTRUCTION AMN 08/06/21 1 FOR CONSTRUCTION RMD 09/01/21 2 FOR CONSTRUCTION AMN 01/03/22 208478 ATC SITE NAME: CHESHIRE T-MOBILE SITE NAME: CTNH568A SITE ADDRESS: 1325 CHESHIRE STREET CHESHIRE, CT 06410 SEAL: ELECTRICAL NOTES: THE FOLLOWING MATERIALS SHALL BE USED: PORTLAND CEMENT: C O N S U L T I N G MADISON SPLICES OF WWF, AT ALL SPLICED EDGES, SHALL BE SUCH THAT THE OVERLAP MEASURED BETWEEN OUTERMOST CROSS WIRES OF EACH FABRIC SHEET IS NOT LESS THAN THE SPACING OF THE CROSS WIRE PLUS 2 INCHES, NOR LESS THAN 6". 20. CONCRETE AND REINFORCING STEEL NOTES: DESIGN AND CONSTRUCTION OF ALL CONCRETE ELEMENTS SHALL CONFORM TO THE LATEST EDITIONS OF ALL APPLICABLE CODES INCLUDING: ACI 301 "SPECIFICATIONS FOR STRUCTURAL CONCRETE FOR BUILDINGS", ACI 117 "SPECIFICATIONS FOR TOLERANCES FOR CONCRETE CONSTRUCTION AND MATERIALS", AND ACI 318 "BUILDING CODE REQUIREMENTS FOR REINFORCED CONCRETE." Doing Business as ATC SITE NUMBER: STRUCTURAL STEEL ROLLED SHAPES, PLATES AND BARS SHALL CONFORM TO THE FOLLOWING ASTM DESIGNATIONS: A. Engineering & Design 135 New Road 19. 1. 15. 7. B. G. 2. A 3/4" CHAMFER SHALL BE PROVIDED AT ALL EXPOSED EDGES OF CONCRETE IN ACCORDANCE WITH ACI 301 SECTION 4.2.4, UNLESS NOTED OTHERWISE. WORK INCLUDED: A. ALL WORK SHALL BE INSTALLED IN A FIRST CLASS, NEAT AND WORKMANLIKE MANNER BY MECHANICS SKILLED IN THE TRADE INVOLVED. THE QUALITY OF WORKMANSHIP SHALL BE SUBJECT TO THE APPROVAL OF THE T-MOBILE REP. ANY WORK FOUND BY THE T-MOBILE REP TO BE OF INFERIOR QUALITY AND/OR WORKMANSHIP SHALL BE REPLACED AND/OR REWORKED AT CONTRACTOR EXPENSE UNTIL APPROVAL IS OBTAINED. STRUCTURAL STEEL SHALL CONFORM TO THE LATEST EDITION OF THE AISC “SPECIFICATION FOR THE DESIGN, FABRICATION AND ERECTION OF STRUCTURAL STEEL FOR BUILDINGS.” 6. SPECIAL CONSTRUCTION ANTENNA INSTALLATION NOTES: STRUCTURAL STEEL NOTES: 1. MINIMUM CONCRETE COVER FOR REINFORCING STEEL SHALL BE NO LESS THAN 3". www.colliersengineering.com G. H. 30. 4. F. 5. ALL DISCREPANCIES FROM WHAT IS SHOWN ON THESE CONSTRUCTION DRAWINGS SHALL BE COMMUNICATED TO ATC ENGINEERING IMMEDIATELY FOR CORRECTION OR RE-DESIGN. FAILURE TO COMMUNICATE DIRECTLY WITH ATC ENGINEERING OR ANY CHANGES FROM THE DESIGN CONDUCTED WITHOUT PRIOR APPROVAL FROM ATC ENGINEERING SHALL BE THE SOLE RESPONSIBILITY OF THE GENERAL CONTRACTOR. Digitally signed by Eric Anderson Date: 2022.01.04 12:37:07-05'00' DATE DRAWN: 08/02/21 ATC JOB NO: 13704270_D3 CUSTOMER ID: CTNH568A CUSTOMER #: CTNH568A GENERAL NOTES SHEET NUMBER: REVISION: G-002 2 Copyright © 2022 ATC IP LLC, All Rights Reserved. GENERAL CONSTRUCTION NOTES: www.colliersengineering.com Doing Business as C O N S U L T I N G MADISON 135 New Road Madison, CT 06443 Phone: 860.395.0055 COLLIERS ENGINEERING & DESIGN CT, P.C. DOING BUSINESS AS MASER CONSULTING Copyright © 2022. Colliers Engineering & Design All Rights Reserved. This drawing and all the information contained herein is authorized for use only by the party for whom the services were contracted or to whom it is certified. This drawing may not be copied, reused, disclosed, distributed or relied upon for any other purpose without the express written consent of Colliers Engineering & Design. REV. DESCRIPTION A PRELIM BY DATE RMD 08/02/21 0 FOR CONSTRUCTION AMN 08/06/21 1 FOR CONSTRUCTION RMD 09/01/21 2 FOR CONSTRUCTION AMN 01/03/22 ATC SITE NUMBER: 208478 ATC SITE NAME: CHESHIRE T-MOBILE SITE NAME: CTNH568A SITE ADDRESS: 1325 CHESHIRE STREET CHESHIRE, CT 06410 SEAL: Digitally signed by Eric Anderson Date: 2022.01.04 12:37:10-05'00' 1 08/02/21 ATC JOB NO: 13704270_D3 CUSTOMER ID: CTNH568A CUSTOMER #: CTNH568A OVERALL SITE PLAN OVERALL SITE PLAN GRAPHIC SCALE ### DATE DRAWN: 0 ( IN FEET ) 1 UNIT = ### FEET ## ### SHEET NUMBER: REVISION: C-001 2 Copyright © 2022 ATC IP LLC, All Rights Reserved. Engineering & Design Engineering & Design X X X X X X X X X www.colliersengineering.com X LEGEND Doing Business as C O N S U L T I N G MADISON X GROUNDING TEST WELL AUTOMATIC TRANSFER SWITCH BOLLARD CELL SITE CABINET DISCONNECT ELECTRICAL FIBER GENERATOR GENERATOR RECEPTACAL HAND HOLE, VAULT ICE BRIDGE KENTROX BOX LIGHTING CONTROL METER PULL BOX POWER POLE TELCO TRANSFORMER CHAINLINK FENCE 135 New Road X Madison, CT 06443 Phone: 860.395.0055 X COLLIERS ENGINEERING & DESIGN CT, P.C. DOING BUSINESS AS MASER CONSULTING X X Copyright © 2022. Colliers Engineering & Design All Rights Reserved. This drawing and all the information contained herein is authorized for use only by the party for whom the services were contracted or to whom it is certified. This drawing may not be copied, reused, disclosed, distributed or relied upon for any other purpose without the express written consent of Colliers Engineering & Design. REV. DESCRIPTION A PRELIM BY DATE RMD 08/02/21 X X X X 0 FOR CONSTRUCTION AMN 08/06/21 1 FOR CONSTRUCTION RMD 09/01/21 2 FOR CONSTRUCTION AMN 01/03/22 X ATC SITE NUMBER: 208478 X ATS B CSC D E F GEN G HH, V IB K LC M PB PP T TRN X IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO COORDINATE WITH THE T-MOBILE REPRESENTATIVE AND LOCAL UTILITY COMPANY FOR THE INSTALLATION OF CONDUITS, CONDUCTORS, BREAKERS, DISCONNECTS, OR ANY OTHER EQUIPMENT REQUIRED FOR ELECTRICAL SERVICE. ALL ELECTRICAL WORK SHALL BE PERFORMED IN ACCORDANCE WITH LATEST EDITION OF THE STATE AND NATIONAL CODES, ORDINANCES AND REGULATIONS APPLICABLE TO THIS PROJECT. X 3. X ICE BRIDGE, CABLE LADDER, COAX PORT, AND COAX CABLE ARE SHOWN FOR REFERENCE ONLY. CONTRACTOR SHALL CONFIRM THE EXACT LOCATION OF ALL PROPOSED AND EXISTING EQUIPMENT AND STRUCTURES DEPICTED ON THIS PLAN. BEFORE UTILIZING EXISTING CABLE SUPPORTS, COAX PORTS, INSTALLING NEW PORTS OR ANY OTHER EQUIPMENT, CONTRACTOR SHALL VERIFY ALL ASPECTS OF THE COMPONENTS MEET THE ATC SPECIFICATIONS. X 2. X THIS SITE PLAN REPRESENTS THE BEST PRESENT KNOWLEDGE AVAILABLE TO THE ENGINEER AT THE TIME OF THIS DESIGN. THE CONTRACTOR SHALL VISIT THE SITE PRIOR TO CONSTRUCTION AND VERIFY ALL EXISTING CONDITIONS RELATED TO THE SCOPE OF WORK FOR THIS PROJECT. X 1. X X ATC SITE NAME: CHESHIRE X X 1 R-607 PROPOSED T-MOBILE GENERATOR T-MOBILE SITE NAME: CTNH568A X SITE ADDRESS: 1325 CHESHIRE STREET CHESHIRE, CT 06410 X X 1 C-502 SEAL: PROPOSED T-MOBILE CABINETS AND CONCRETE PAD WITHIN A 10' X 15' LEASE AREA 1 PROPOSED ICE BRIDGE C-503 (LENGTH 11' ±) X X X X PROPOSED T-MOBILE (3) 1.99" HYBRID CABLES (ROUTED PER TOWER NOTE 2) (REFER TO PROPOSED CABLE LENGTH NOTE ON THIS PAGE) X X X X Digitally signed by Eric Anderson Date: 2022.01.04 12:37:12-05'00' X X PROPOSED CABLE LENGTH: X X ROUTE PROPOSED CABLES ALONG SAME PATH AS EXISTING CABLES AND IN ACCORDANCE WITH STRUCTURAL ANALYSIS. IF ADEQUATE SPACE EXISTS, ROUTE CABLES THROUGH ENTRY PORT HOLE, UP INSIDE OF MONOPOLE, AND THROUGH EXIT PORT HOLE. IF ROUTING OUTSIDE THE MONOPOLE, ATTACH CABLES USING STAND-OFF ADAPTERS MOUNTED TO TOWER USING STAINLESS STEEL BANDING. ADEQUATELY SECURE CABLES USING EITHER APPROPRIATELY SIZED STAINLESS STEEL SNAP-INS OR MOUNTING HARDWARE AND BRACKETS AS SPECIFIED BY CABLE MANUFACTURER. X 2. ESTIMATED LENGTH OF PROPOSED CABLE IS 165'. ESTIMATED LENGTH OF CABLE WAS PROVIDED BY CUSTOMER OR CALCULATED BY ADDING THE RAD CENTER AND THE DISTANCE FROM THE SHELTER ENTRY PLATE TO THE TOWER (ALONG THE ICE BRIDGE) AND A SAFETY FACTOR MEASUREMENT OF 15% (OF THE TWO PREVIOUS VALUES), CDS DEFER TO GREATEST CABLE LENGTH. DATE DRAWN: 08/02/21 ATC JOB NO: 13704270_D3 CUSTOMER ID: CTNH568A CUSTOMER #: CTNH568A X 1. X X 1 X X X X X DETAILED SITE PLAN X X X X X X X DETAILED SITE PLAN GRAPHIC SCALE 10 0 ( IN FEET ) 1 UNIT = 10 FEET 5 10 SHEET NUMBER: REVISION: C-101 2 Copyright © 2022 ATC IP LLC, All Rights Reserved. SITE PLAN NOTES: Engineering & Design www.colliersengineering.com Doing Business as C O N S U L T I N G MADISON 135 New Road Madison, CT 06443 Phone: 860.395.0055 COLLIERS ENGINEERING & DESIGN CT, P.C. DOING BUSINESS AS MASER CONSULTING Copyright © 2022. Colliers Engineering & Design All Rights Reserved. This drawing and all the information contained herein is authorized for use only by the party for whom the services were contracted or to whom it is certified. This drawing may not be copied, reused, disclosed, distributed or relied upon for any other purpose without the express written consent of Colliers Engineering & Design. PROPOSED T-MOBILE EQUIPMENT RAD CENTER @ 134' AGL 1 C-401 REV. DESCRIPTION A PRELIM BY DATE RMD 08/02/21 0 FOR CONSTRUCTION AMN 08/06/21 1 FOR CONSTRUCTION RMD 09/01/21 2 FOR CONSTRUCTION AMN 01/03/22 PROPOSED T-MOBILE EQUIPMENT ATC SITE NUMBER: 208478 ATC SITE NAME: CHESHIRE T-MOBILE SITE NAME: CTNH568A SITE ADDRESS: 1325 CHESHIRE STREET CHESHIRE, CT 06410 SEAL: TOWER NOTE: 1. IT IS THE CONTRACTOR'S RESPONSIBILITY TO CONFIRM WITH THE PROJECT MANAGER THAT THEY HAVE THE MOST RECENT VERSION OF THE STRUCTURAL ANALYSIS BEFORE COMMENCING WORK. EXISTING AND PROPOSED TOWER APPURTENANCES, MOUNTS, AND ANTENNAS ARE SHOWN BASED ON THE STRUCTURAL ANALYSIS. 2. WHERE APPLICABLE, ALL NEW ANTENNAS, EQUIPMENT, MOUNTS, CABLING, ETC. SHALL BE PAINTED/SOCKED TO MATCH EXISTING EQUIPMENT IN ACCORDANCE WITH FAA, JURISDICTION, AND/OR OTHER LOCAL REQUIREMENTS. 3. ROUTE PROPOSED CABLES ALONG SAME PATH AS EXISTING CABLES AND IN ACCORDANCE WITH STRUCTURAL ANALYSIS. IF ADEQUATE SPACE EXISTS, ROUTE CABLES THROUGH ENTRY PORT HOLE, UP INSIDE OF MONOPOLE, AND THROUGH EXIT PORT HOLE. IF ROUTING OUTSIDE THE MONOPOLE, ATTACH CABLES USING STAND-OFF ADAPTERS MOUNTED TO TOWER USING STAINLESS STEEL BANDING. ADEQUATELY SECURE CABLES USING EITHER APPROPRIATELY SIZED STAINLESS STEEL SNAP-INS OR MOUNTING HARDWARE AND BRACKETS AS SPECIFIED BY CABLE MANUFACTURER. 4. TOWER ELEVATIONS ARE MEASURED FROM TOP OF BASE PLATE TO MATCH STRUCTURAL ANALYSIS. ELEVATIONS DO NOT REFLECT TRUE ABOVE GROUND LEVEL (A.G.L.) 1 TOWER ELEVATION SCALE: N.T.S. Digitally signed by Eric Anderson Date: 2022.01.04 12:37:14-05'00' DATE DRAWN: 08/02/21 ATC JOB NO: 13704270_D3 CUSTOMER ID: CTNH568A CUSTOMER #: CTNH568A TOWER ELEVATION SHEET NUMBER: REVISION: C-201 2 Copyright © 2022 ATC IP LLC, All Rights Reserved. PER MOUNT ANALYSIS COMPLETED BY CENTEK, DATED 01/03/22, THE PROPOSED MOUNT CAN ADEQUATELY SUPPORT THE PROPOSED LOADING. A1 Engineering & Design A2 www.colliersengineering.com 1 C-501 Doing Business as 2 PROPOSED PLATFORM (1 PER SECTOR) (TYP. 3) C-501 PROPOSED AIR6449 B41 ANTENNA (1 PER SECTOR) (TYP. 3) C O N S U L T I N G MADISON 135 New Road Madison, CT 06443 Phone: 860.395.0055 COLLIERS ENGINEERING & DESIGN CT, P.C. DOING BUSINESS AS MASER CONSULTING C2 B1 0° Z.= A 24 A MM GA AZ .= BE TA 0° PROPOSED STACK MOUNTED RADIO 4460 B25/B66 RRU (1 PER SECTOR) (TYP. 3) 1 C-501 PROPOSED APXVAALL24 43-U-A20 ANTENNA (1 PER SECTOR) (TYP. 3) C1 B2 0° .= AZ 24 A MM GA AZ .= BE TA Copyright © 2022. Colliers Engineering & Design All Rights Reserved. This drawing and all the information contained herein is authorized for use only by the party for whom the services were contracted or to whom it is certified. This drawing may not be copied, reused, disclosed, distributed or relied upon for any other purpose without the express written consent of Colliers Engineering & Design. 12 1 C-501 REV. DESCRIPTION A PRELIM BY DATE RMD 08/02/21 0 FOR CONSTRUCTION AMN 08/06/21 1 FOR CONSTRUCTION RMD 09/01/21 2 FOR CONSTRUCTION AMN 01/03/22 ATC SITE NUMBER: 12 208478 0° ATC SITE NAME: CHESHIRE PROPOSED STACK MOUNTED RADIO 4480 B71/B85A RRU (1 PER SECTOR) (TYP. 3) 1 C-501 T-MOBILE SITE NAME: CTNH568A SITE ADDRESS: 1325 CHESHIRE STREET CHESHIRE, CT 06410 SEAL: FINAL ANTENNA PLAN 1 SCALE: N.T.S. FINAL ANTENNA SCHEDULE LOCATION ANTENNA SUMMARY SECTOR RAD AZ ALPHA 134' 0° BETA GAMMA 134' 134' 120° 240° NON ANTENNA SUMMARY ADDITIONAL TOWER MOUNTED EQUIPMENT RADIO 4460 B25/B66 RADIO 4480 B71/B85 POS ANTENNA BAND MECH/ELEC D-TILT A1 APXVAALL24 43-U-NA20 L600/L700/L1900/L2100/ N600/G1900/U2100 0/0 A2 AIR6449 B41 5G 0/0 - B1 APXVAALL24 43-U-NA20 L600/L700/L1900/L2100/ N600/G1900/U2100 0/0 RADIO 4460 B25/B66 RADIO 4480 B71/B85 B2 AIR6449 B41 5G 0/0 - C1 APXVAALL24 43-U-NA20 L600/L700/L1900/L2100/ N600/G1900/U2100 0/0 RADIO 4460 B25/B66 RADIO 4480 B71/B85 C2 AIR6449 B41 5G 0/0 - (3) 1.99" HYBRID CABLES 1. CONFIRM WITH T-MOBILE REP FOR APPLICABLE UPDATES/REVISIONS AND MOST RECENT RFDS FOR NSN CONFIGURATION (CONFIG). GC TO CAP ALL UNUSED PORTS. 2. CONFIRM SPACING OF PROPOSED EQUIP DOES NOT CAUSE TOWER CONFLICTS NOR IMPEDE TOWER CLIMBING PEGS. 2 ANTENNA SCHEDULE Digitally signed by Eric Anderson Date: 2022.01.04 12:37:16-05'00' DISTRIBUTION BOX / CABLING DATE DRAWN: 08/02/21 ATC JOB NO: 13704270_D3 CUSTOMER ID: CTNH568A CUSTOMER #: CTNH568A ANTENNA INFORMATION & SCHEDULE SHEET NUMBER: REVISION: C-401 2 Copyright © 2022 ATC IP LLC, All Rights Reserved. ALPHA AZ.= 0° AZ.= 0° ALPHA PER MOUNT ANALYSIS COMPLETED BY CENTEK, DATED 01/03/22, THE PROPOSED MOUNT CAN ADEQUATELY SUPPORT THE PROPOSED LOADING. PROPOSED PANEL ANTENNA (MOUNT PER MANUFACTURER'S SPECIFICATION) Engineering & Design PROPOSED UPPER RAIL KIT (2-3/8" OD X 150" SCH 40 ) www.colliersengineering.com Doing Business as C O N S U L T I N G MADISON 135 New Road PROPOSED RRU Madison, CT 06443 Phone: 860.395.0055 COLLIERS ENGINEERING & DESIGN CT, P.C. DOING BUSINESS AS MASER CONSULTING Copyright © 2022. Colliers Engineering & Design All Rights Reserved. This drawing and all the information contained herein is authorized for use only by the party for whom the services were contracted or to whom it is certified. This drawing may not be copied, reused, disclosed, distributed or relied upon for any other purpose without the express written consent of Colliers Engineering & Design. PROPOSED ANTENNA RAD CENTER REV. DESCRIPTION A PRELIM BY DATE RMD 08/02/21 0 FOR CONSTRUCTION AMN 08/06/21 1 FOR CONSTRUCTION RMD 09/01/21 2 FOR CONSTRUCTION AMN 01/03/22 ATC SITE NUMBER: 2-3/8" O.D. X 96" PIPE SCH 40 208478 PROPOSED 2-3/8" O.D. X 96" LONG PIPE ATC SITE NAME: CHESHIRE PROPOSED PLATFORM MOUNT 1 2 C-501 PROPOSED ANTENNA MOUNTING DETAIL (ELEVATION) SCALE: NOT TO SCALE T-MOBILE SITE NAME: PROPOSED PLATFORM MOUNT (SITE PRO P/N: RMQP-4096-HK) 2 ISOMETRIC PLATFORM DETAIL SCALE: N.T.S. CTNH568A SITE ADDRESS: 1325 CHESHIRE STREET CHESHIRE, CT 06410 SEAL: Digitally signed by Eric Anderson Date: 2022.01.04 12:37:18-05'00' DATE DRAWN: 08/02/21 ATC JOB NO: 13704270_D3 CUSTOMER ID: CTNH568A CUSTOMER #: CTNH568A MOUNT DETAILS SHEET NUMBER: REVISION: C-501 2 Copyright © 2022 ATC IP LLC, All Rights Reserved. PROPOSED UPPER RAIL 25kW AC DIESEL GENERATOR (USE GALVANIZED HILTI EXPANSION ANCHORS OR, APPROVED EQUAL, FOR EQUIPMENT ANCHORAGE) Engineering & Design PROPOSED T-MOBILE 10' X 15' CONCRETE PAD & LEASE AREA 4 C-503 www.colliersengineering.com H-FRAME NOTES: Doing Business as 1. 2. PROPOSED T-MOBILE 10' X 15' ICE CANOPY (SITE PRO1 P/N MPCOV1010) (SEE NOTE 3) IF IT IS NECESSARY TO EXTEND THE H-FRAME, AN ADDITIONAL POST WILL ALWAYS BE REQUIRED. SPRAY ENDS OF UNISTRUT WITH COLD GALVANIZING SPRAY PAINT, ALLOW TO DRY, THEN COVER WITH RUBBER PROTECTIVE CAPS FOR SAFETY. 4. UNISTRUT TO BE CUT FLUSH WITH NO SHARP OR JAGGED EDGES. 5. ALL PROPOSED HARDWARE TO BE MOUNTED PER MANUFACTURERS SPECS. 9'-0" 6 4'-6" 2 C-502 A Madison, CT 06443 Phone: 860.395.0055 PROPOSED UNISTRUTS TO BE FIELD CUT AND SHOULD NOT EXTEND MORE THAN 6 INCHES BEYOND THE LAST POST. 3. 4'-6" PIPE CAP COLLIERS ENGINEERING & DESIGN CT, P.C. DOING BUSINESS AS MASER CONSULTING Copyright © 2022. Colliers Engineering & Design All Rights Reserved. This drawing and all the information contained herein is authorized for use only by the party for whom the services were contracted or to whom it is certified. This drawing may not be copied, reused, disclosed, distributed or relied upon for any other purpose without the express written consent of Colliers Engineering & Design. REV. DESCRIPTION A PRELIM BY DATE RMD 08/02/21 0 FOR CONSTRUCTION AMN 08/06/21 1 FOR CONSTRUCTION RMD 09/01/21 2 FOR CONSTRUCTION AMN 01/03/22 A PROPOSED H-FRAME ATC SITE NUMBER: 208478 PROPOSED AUTOMATIC TRANSFER SWITCH 15'-0" C O N S U L T I N G MADISON 135 New Road ATC SITE NAME: CHESHIRE 1-5/8" X 10'-0" UNISTRUT (FIELD LOCATE) PROPOSED POWER PANEL (SEE PANEL SCHEDULE ON E-601) PROPOSED 6160 ENCLOSURE T-MOBILE SITE NAME: CTNH568A 1 R-603 SITE ADDRESS: 1325 CHESHIRE STREET CHESHIRE, CT 06410 SEAL: 2 5 PROPOSED B160 BATTERY CABINET 3 1 R-604 3"Ø SCH.40 PIPE (GALV.) 6" PROPOSED HOFFMAN BOX (BELOW) PROPOSED PURCELL CABINET 4 3 16" 1-1/8" (TYP) 5" 6" PROPOSED LED LUMINAIRE 1 C-503 Digitally signed by Eric Anderson Date: 2022.01.04 12:37:21-05'00' 5" 6" 1 8" X 8" X 1/4" TH. BASE PLATE PROPOSED ICE BRIDGE SECTION A-A UNISTRUT PIPE/CONDUIT CLAMP P1119 OR P2558-35 (GALV.) (TYP.) FOLLOW MANUFACTURER RECOMMENDATIONS FOR BOLT TORQUE 2 EQUIPMENT POWER NOTES: NOTE: 1. CABINETS SHALL BE ORIENTED AND INSTALLED EXACTLY AS SHOWN 2. WEIGHT OF BTS UNIT IS 1,060 LBS (WEIGHT IS WITHOUT EQUIPMENT) 5/8"Ø HILTI ANCHOR BOLTS W/3" EMBEDMENT (TYP 4 EACH SUPPORT) TYPICAL H-FRAME DETAIL SCALE: NOT TO SCALE DATE DRAWN: 08/02/21 ATC JOB NO: 13704270_D3 CUSTOMER ID: CTNH568A CUSTOMER #: CTNH568A 1 2" CONDUIT W/ 3-#3/0 CU, (1) #6 AWG G, PPC POWER 2 2" CONDUIT W/ MULE TAPE FOR TELCO FEEDER SERVICE TO TELCO SOURCE PER UTILITY 3 2-#12, 1 #12G IN 3/4" CONDUIT FROM TELCO CAB TO 6160 4 3-#1/0, 1-#6 IN 2" CONDUIT SHEET NUMBER: REVISION: 5 2" CONDUIT, FOR CAT6 C-502 2 1 DETAILED EQUIPMENT LAYOUT SCALE: NOT TO SCALE CONSTRUCTION DETAILS Copyright © 2022 ATC IP LLC, All Rights Reserved. 10'-0" 2'-0" APPROX. MATCH EXISTING MATERIAL & GRADE G.P.S. ANTENNA (PROVIDED BY CARRIER) 13'-4" PIPE COLUMN (POST MOUNT) OR 10'-6" PIPE COLUMN (PAD MOUNT) 1-1/4" SCH 40 X 18" LNG MIN. SS OR GALV PIPE WARNING TAPE 1/2" X 8" THREADED ROD (GALV.) PIPE-TO-PIPE CLAMP VERIFY SIZE (GALV.) UNEXCAVATED SOIL Engineering & Design #2 AWG BARE TINNED SOLID COPPER WIRE CADWELD FROM GPS MOUNT PIPE TO COAX CABLE PIPE SUPPORT OR TOWER MEMBER 4" 12" MIN 24" WAVEGUIDE BRIDGE SUPPORT BRACKET TRENCH COMPACT FILL (90%) OR AS PER UTILITY COMPANY REQUIREMENTS SAFETY GRATING 24" X 10' www.colliersengineering.com Doing Business as ICE BRIDGE SUPPORT POST OR TOWER MEMBER 2"Ø SCH 40 CONDUIT (TELCO) (W/ 200 LB MULE TAPE) CLEAN SAND SUITABLE FOR CONDUIT BEDDING (SEE NOTE 4) 2"Ø SCH 40 PVC CONDUIT (ELECTRIC) 12" MIN. TRENCH NOTES: 1. IF FREE OF ORGANIC OR OTHER DELETERIOUS MATERIAL, EXCAVATED MATERIAL MAY BE USED FOR BACKFILL. 2. IF NOT, PROVIDE CLEAN, COMPACTIBLE MATERIAL. COMPACT IN 8" LIFTS. REMOVE ANY LARGE ROCKS PRIOR TO BACKFILLING. CONTRACTOR TO VERIFY LOCATION OF EXISTING U/G UTILITIES PRIOR TO DIGGING. VERTICAL TRAPEZE SECTION 3. 4. UNISTRUT P1000 X 12" (ATTACH ON CABINET SIDE LEG FOR COAX SUPPORT) IF CURRENT AS-BUILT DRAWINGS ARE NOT AVAILABLE CONTRACTOR SHALL HAND DIG U/G TRENCHING. CONDUIT (SHALL BE USED FOR MECHANICAL PROTECTION) Madison, CT 06443 Phone: 860.395.0055 COLLIERS ENGINEERING & DESIGN CT, P.C. DOING BUSINESS AS MASER CONSULTING INSULATED METALLIC BUSHING 1/2"Ø COAX CABLE (OR EQUAL) MIN. BENDING RADIUS PER MFG'S SPECIFICATIONS C O N S U L T I N G MADISON 135 New Road #6 AWG GROUNDING KIT CABLE (PROVIDED WITH KIT) 2 HOLE LUG SUITABLE FOR #2 AWG BCW NOTE: 1. GPS SHALL BE PLACED WITH CLEAR SIGHT LINE TO THE SOUTHERN SKY. 2. CONTRACTOR TO SUPPLY COAX FOR GPS UNIT. Copyright © 2022. Colliers Engineering & Design All Rights Reserved. This drawing and all the information contained herein is authorized for use only by the party for whom the services were contracted or to whom it is certified. This drawing may not be copied, reused, disclosed, distributed or relied upon for any other purpose without the express written consent of Colliers Engineering & Design. REV. DESCRIPTION A PRELIM BY DATE RMD 08/02/21 0 FOR CONSTRUCTION AMN 08/06/21 1 FOR CONSTRUCTION RMD 09/01/21 2 FOR CONSTRUCTION AMN 01/03/22 GPS ANTENNA ATTACHMENT DETAIL 3 SCALE: NOT TO SCALE ATC SITE NUMBER: 208478 CONCRETE ENCASE CONDUIT WHEN TRENCHING UNDER SITE ACCESS ROAD. ATC SITE NAME: TELCO AND POWER CONDUIT JOINT TRENCH 2 CHESHIRE SCALE: N.T.S. T-MOBILE SITE NAME: 3'-6" (MIN.) 3" CTNH568A 15'-0" SITE ADDRESS: 1325 CHESHIRE STREET CHESHIRE, CT 06410 3/4" CHAMFER 12"Ø CONCRETE FOOTING (WHERE APPLICABLE) SEAL: MOUNT TO CONCRETE PAD (WHERE APPLICABLE) PROPOSED PAD 4" 10'-4" COLUMN & BASE SHOE WB-K210-S (SOLD SEPARATELY) COMMSCOPE: WB-K210-B (DIRECT BURIAL POSTS) 10'-0" COMMSCOPE: WB-K210-S (CONCRETE PAD SHOE POSTS) CONSTRUCTION NOTE: Digitally signed by Eric Anderson Date: 2022.01.04 12:37:23-05'00' PAD NOTES: WAVEGUIDE BRIDGE KIT 1. SUBGRADE AND FILL SHALL CONSIST OF CLEAN SOIL. DELETRIOUS MATERIAL AND ORGANICS SHALL BE REMOVED. 2. MECHANICALLY COMPACT FOOTPRINT OF PAD PLUS 2' PERIMETER. 3. USE GALVANIZED HILTI EXPANSION ANCHORS OR, APPROVED EQUAL, FOR EQUIPMENT ANCHORAGE. DATE DRAWN: 08/02/21 ATC JOB NO: 13704270_D3 FOR SIZE AND LOCATION OF ANCHORS AND OTHER REQUIREMENT, SEE EQUIPMENT VENDOR DRAWINGS. CUSTOMER ID: CTNH568A CUSTOMER #: CTNH568A SCALE: NOT TO SCALE #3 @ 11-2/3" 3" #3 @ 14-1/2" 3" 1 4. PAD NOTES: 1. 2. PADS SHALL BE PRE-CAST MATCHING THIS DESIGN WHERE ALLOWED BY LOCAL JURISDICTION. REFER TO CONCRETE & REINFORCED STEEL NOTES ON SHEET G-002 & ATC SPEC 033000 FOR CAST-IN-PLACE PADS. 4 REINFORCED PAD LAYOUT SCALE: NOT TO SCALE 6" 2. 6" EXISTING CRUSHED STONE OR GRAVEL (SEE NOTE 2) INSTALL ICE BRIDGE TO ALLOW 7 FEET CLEARANCE ABOVE GRADE TO LOWEST APPURTENANCE. INSTALL PER MANUFACTURES SPECIFICATION. 3" 1. 5 GRAVEL PREPARATION SCALE: NOT TO SCALE CONSTRUCTION DETAILS SHEET NUMBER: REVISION: C-503 2 Copyright © 2022 ATC IP LLC, All Rights Reserved. 2'-0"± 2. 2. 3. 4. 5. GROUNDING PLAN LEGEND: EXOTHERMIC WELD 1 C-502 PROPOSED CONCRETE PAD & EQUIPMENT LAYOUT 2-#12, 1 #12G IN 3/4" CONDUIT FROM TELCO CAB TO 6160 4 3-#1/0, 1-#6 IN 2" CONDUIT 5 BOND TO TOWER GROUND RING 2 #2 AWG BOND FROM VERTICAL H-FRAME AND ICE BRIDGE POST TO EXTERNAL GROUND RING (TYP. EVERY POST). www.colliersengineering.com 3 5 PROPOSED ENCLOSURE 6160 CABINET Doing Business as C O N S U L T I N G 135 New Road #2 AWG SBTC BOND FROM TOWER GROUND RING TO EQUIPMENT. 4 EQUIPMENT BOND TO GROUND RING (TYP.) 5 5/8Ø" X 10 FT GROUND ROD. 4 Madison, CT 06443 Phone: 860.395.0055 COLLIERS ENGINEERING & DESIGN CT, P.C. DOING BUSINESS AS MASER CONSULTING Copyright © 2022. Colliers Engineering & Design All Rights Reserved. This drawing and all the information contained herein is authorized for use only by the party for whom the services were contracted or to whom it is certified. This drawing may not be copied, reused, disclosed, distributed or relied upon for any other purpose without the express written consent of Colliers Engineering & Design. REV. DESCRIPTION A PRELIM BY DATE RMD 08/02/21 0 FOR CONSTRUCTION AMN 08/06/21 1 FOR CONSTRUCTION RMD 09/01/21 2 FOR CONSTRUCTION AMN 01/03/22 2 PROPOSED B160 BATTERY CABINET PROPOSED H-FRAME ATC SITE NUMBER: 208478 1 3 ATC SITE NAME: 2 CHESHIRE T-MOBILE SITE NAME: CTNH568A SITE ADDRESS: 1325 CHESHIRE STREET CHESHIRE, CT 06410 DETAILED GROUNDING PLAN 1 SCALE: NOT TO SCALE SEAL: PROPOSED SCHNEIDER ELECTRIC SQUARE D GENERATOR INTERLOCK KIT (SEE PANEL SCHEDULE ON E-601) PROPOSED 200A, 120/240V, 1PH, 3W, 60 HZ UTILITY METER IN EXISTING EMPTY METER SOCKET (COORDINATE WITH LOCAL UTILITY COMPANY) CONDUCTIVE OBJECTS, SUCH AS FENCES, SHALL BE BONDED TO THE GROUNDING SYSTEM IF WITHIN 20’ OF THE TOWER GROUNDING PROPOSED 200/2 SYSTEM, OR 5’ OF ANY OTHER GROUNDED COMPONENT. SERVICE MAIN BREAKER SUITABLE AND EQUIPMENT POWER NOTES: LISTED FOR THE APPLICATION 2" CONDUIT W/ 3-#3/0 CU, (1) #6 AWG G, PPC POWER 1 3 1 MADISON GROUND RINGS SHALL BE: A. MINIMUM 30” BELOW GRADE, OR BELOW FROST LINE WHICHEVER IS DEEPER. B. MINIMUM 2’ FROM FOUNDATIONS, FOOTINGS, OTHER GROUNDING SYSTEMS AND ALL CONDUCTIVE OBJECTS. C. WITH MINIMUM 12" BEND RADII. D. WITH ALL CONNECTIONS IN CONTACT WITH EARTH, BONDED BY EXOTHERMIC WELDING. E. BONDED TO A SINGLE POINT GROUND (SPG) WITH A SINGLE WIRE AS INDICATED ON DRAWINGS. 2" CONDUIT W/ MULE TAPE FOR TELCO FEEDER SERVICE TO TELCO SOURCE PER UTILITY Engineering & Design GROUNDING KEYED NOTES: INSTALL ALL GROUNDING RINGS AND RADIALS WITH CONDUCTIVE CEMENT, SANKOSHA AS DISTRIBUTED BY ELECTRIC MOTION COMPANY, INC., WINSTED, CT 06098, OR AS SPECIFICALLY INDICATED. INSTALL PER MANUFACTURER’S SPECIFICATIONS. 2 TEST WELL MECHANICAL WELD GROUNDING CONDUCTORS SHALL: A. BE #2 AWG SOLID BARE TINNED COPPER (SBTC) FOR ALL GROUNDING SYSTEM WIRE UNLESS OTHERWISE NOTED, OR OTHERWISE REQUIRED BY CODE. B. BE MINIMUM 12” BEND RADIUS. KEEP NUMBER OF BENDS TO A MINIMUM. C. AVOID LONG BONDING CONNECTION RUNS. MAKE DIRECT AS POSSIBLE. D. NOT HAVE ANY U-SHAPED RUNS. E. BE IN NON-METALLIC CONDUIT ONLY, IF IN CONDUIT. F. BE PLACED THROUGH NON-METALLIC SLEEVES IN FLOORS, WALLS, CEILINGS, ETC. G. PROTECTED IN NON-METALLIC CONDUIT WHERE EXPOSED ABOVE GRADE. GROUND RODS SHALL BE: A. MINIMUM 5/8” DIAMETER. B. MINIMUM 10’ LONG. C. COPPER-CLAD GALVANIZED STEEL OR STAINLESS STEEL. D. PLACED IN UNDISTURBED SOIL AND BELOW THE FROST LINE. E. INSTALLED WITH MINIMUM SEPARATION DISTANCE OF TWICE THE DEPTH OF THE ROD(S), OR AS INDICATED ON DRAWINGS. F. MINIMUM TWO (2) RODS ON THE TOWER RING OR ONE (1) PER LEG WHICHEVER IS LARGER, MINIMUM FOUR (4) RODS ON EVERY EQUIPMENT BUILDING RING WITH ONE AT EACH CORNER OR AS INDICATED, MINIMUM ONE (1) ROD FOR POWER SERVICE GROUNDING ELECTRODE, AND MINIMUM ONE (1) ROD AT END OF EACH RADIAL. COPPER GROUND ROD GROUND WIRE PROPOSED ENCLOSURE 6160 (INSTALLED AND CONNECTED AS DIRECTED BY T-MOBILE) PROPOSED B160 CABINET (INSTALLED AND CONNECTED AS DIRECTED BY T-MOBILE) PROPOSED LED LUMINARE PROPOSED H-FRAME Digitally signed by Eric Anderson Date: 2022.01.04 12:37:25-05'00' PROPOSED CIENA M LIGHT SWITCH M RECEPTACLE PROPOSED PLASTIC LAMACOID TAG "T-MOBILE" 3 2 4 2" CONDUIT, FOR CAT6 1 5 3 GROUND PER NEC 5 1 EQUIPMENT POWER AND TELCO SCHEMATIC SCALE: N.T.S. 08/02/21 ATC JOB NO: 13704270_D3 CUSTOMER ID: CTNH568A CUSTOMER #: CTNH568A GROUNDING DETAILS & ELECTRICAL SCHEMATIC 4 1 DATE DRAWN: NOTE: ALL EQUIPMENTS' SHORT-CIRCUIT CURRENT RATING SHALL EXCEED AVAILABLE FAULT CURRENT PER UTILITY SHEET NUMBER: REVISION: E-101 2 Copyright © 2022 ATC IP LLC, All Rights Reserved. GROUNDING NOTES: 1. ALL EQUIPMENT ENCLOSURES, DEVICES AND CONDUITS SHALL BE GROUNDED TO CONFORM WITH THE LATEST REQUIREMENTS OF THE NEC BY THE INSTALLATION OF A SEPARATE, GREEN, INSULATED GROUND CONDUCTOR FOR ALL FEEDER AND BRANCH CIRCUITS. GROUND CONDUCTORS SHALL BE OF THE SIZE INDICATED ON THE DRAWINGS. GROUND CONDUCTORS SHALL BE CONTINUOUS IN LENGTH AND SHALL BE BONDED TO EACH ENCLOSURE THEY PASS THROUGH. CONDUIT SHALL NOT BE USED AS A GROUNDING CONDUCTOR. 3/8" X 1-1/4" SS BOLT (EACH SIDE) PROPOSED JUMPER 3/8" SS LOCK WASHER (EACH SIDE) TO ANTENNA PROPOSED CONNECTOR AND WEATHERPROOFING KIT PROPOSED ANTENNA MASTS PROPOSED WEATHERPROOFING KIT 2 E-501 PROPOSED COAX GROUND KITS 2 PROPOSED CABLE E-501 GROUND KIT Engineering & Design ANTENNA CABLE 2 1/2"Ø MAX www.colliersengineering.com PROPOSED #6 AWG STRANDED CU WIRE WITH GREEN, 600V, THWN INSULATION TO PROPOSED RRU GROUND LUG (TYP.) ANTENNA CABLE TO CABINET (TYP.) Doing Business as #6 AWG STRANDED CU WIRE WITH GREEN, 600V, THWN INSULATION 135 New Road 1/4" X 4" X 6" GROUND BAR (ERICO P/N: EGBA14406CC OR EQUAL) GROUND BAR MOUNTED 3 NEAR/BELOW ANTENNA E-501 (TO BE INSTALLED IF REQUIRED) GROUND BAR NOTES: TO GROUND BAR TO EQUIPMENT NOTES: 1. 2. 1 THIS DETAIL IS INTENDED TO SHOW THE GENERAL GROUNDING REQUIREMENTS. SLIGHT ADJUSTMENTS MAY BE REQUIRED BASED ON EXISTING SITE CONDITIONS. THE CONTRACTOR SHALL MAKE FIELD ADJUSTMENTS AS NEEDED AND INFORM THE CONSTRUCTION MANAGER OF ANY CONFLICTS. SITE GROUNDING SHALL COMPLY WITH T-MOBILE GROUNDING STANDARDS, LATEST EDITION, AND COMPLY WITH T-MOBILE GROUNDING CHECKLIST, LATEST VERSION. WHEN NATIONAL AND LOCAL GROUNDING CODES ARE MORE STRINGENT THEY SHALL GOVERN. Madison, CT 06443 Phone: 860.395.0055 COLLIERS ENGINEERING & DESIGN CT, P.C. DOING BUSINESS AS MASER CONSULTING TWO-HOLE LUG, TO BE USED WITH #2 AWG BCW (LOWER TOWER GROUND BAR ONLY) #6 AWG STRANDED COPPER GROUND WIRE (GROUNDED TO GROUND BAR) GROUNDING CONNECTION TO PROPOSED TMAs PROPOSED GROUNDING CONNECTION TO LIGHTNING PROTECTION SYSTEM 1. GROUND BAR KITS COME WITH ALL HARDWARE, NUTS, BOLTS, WASHERS, ETC. EXCEPT THE STRUCTURAL MOUNTING MEMBER(S). 2. GROUND BAR TO BE BONDED DIRECTLY TO TOWER. Copyright © 2022. Colliers Engineering & Design All Rights Reserved. This drawing and all the information contained herein is authorized for use only by the party for whom the services were contracted or to whom it is certified. This drawing may not be copied, reused, disclosed, distributed or relied upon for any other purpose without the express written consent of Colliers Engineering & Design. REV. DESCRIPTION A PRELIM BY DATE RMD 08/02/21 0 FOR CONSTRUCTION AMN 08/06/21 1 FOR CONSTRUCTION RMD 09/01/21 2 FOR CONSTRUCTION AMN 01/03/22 GROUND KIT NOTES: 1. DO NOT INSTALL CABLE GROUND KIT AT A BEND AND ALWAYS DIRECT GROUND WIRE DOWN TO GROUND BAR. 2. CONTRACTOR SHALL PROVIDE WEATHERPROOFING KIT (ANDREW PART NUMBER 221213) AND INSTALL/TAPE PER MANUFACTURER'S SPECIFICATIONS. ATC SITE NUMBER: 208478 ATC SITE NAME: CHESHIRE TYPICAL ANTENNA GROUNDING DIAGRAM CABLE GROUND KIT CONNECTION DETAIL 2 SCALE: N.T.S. SCALE: N.T.S. 3 TOWER GROUND BAR DETAIL T-MOBILE SITE NAME: SCALE: N.T.S. CTNH568A SITE ADDRESS: 1325 CHESHIRE STREET CHESHIRE, CT 06410 GRADE 1/4"Ø HILTI KWIK BOLT III SEAL: SEE NOTE #4 3/8" THREADED INSULATOR WHERE INDICATED C O N S U L T I N G MADISON GROUNDING KIT PER CABLE MANUFACTURER'S RECOMMENDATIONS (ANDREW OR APPROVED EQUAL) 3/8" X 3/4" SS BOLT (TYP.) #2 SBTC GROUND BAR MOUNTING BRACKET EXOTHERMIC WELD 5/8"Ø X 10'-0" COPPER CLAD STEEL GROUND ROD F E O OD GL AN ND R T O OU GR ALL N 45°. SH EED AY C W EX CT A E DIR FROM TIVE UC . ND CO BODY EXOTHERMIC WELD (THERMOWELD OR EQUIVALENT) PARALLEL, NO T-WELDS ALLOWED (NO SLAG OR DEFORMITIES ALLOWED) Digitally signed by Eric Anderson Date: 2022.01.04 12:37:27-05'00' EXTERIOR GROUND RING #2 SBTC GROUNDING CONDUCTOR 1/4" X 4" X 12" GALVANIZED BUSS BAR NG DI ) EN YP. B T . IN S ( " M IU 12 RAD TWO-HOLE LUG, TO BE USED WITH #2 AWG BCW 3/8" SS LOCK WASHER (TYP.) NOTES: 1. SEPARATION DIMENSION TO BE VERIFIED WITH LOCAL UTILITY COMPANY REQUIREMENTS. GROUND BAR NOTES 1. 2. 2. COORDINATE UTILITY, LOCATE BEFORE DIGGING. GROUND KITS COME WITH ALL HARDWARE, NUTS, BOLTS, WASHERS, ETC. EXCEPT THE STRUCTURAL MOUNTING MEMBER(S). 3. CONDUIT TRENCHING DEPTHS AT 36" OR 6" BELOW FROST LINE, WHICHEVER IS GREATER. GROUND BAR SHALL BE BOLTED TO STRUCTURAL MEMBER OR ANCHORED TO CONCRETE SLAB W/ HILTI KWIK BOLT III. 4. ALL RING AND RADIAL DEPTHS AT 30" OR 6" BELOW FROST LINE, WHICHEVER IS GREATER. 4 MAIN GROUND BAR DETAIL SCALE: N.T.S. 5 GROUND ROD DETAIL SCALE: N.T.S. JUMPER, #2 SBTC GROUNDING CONDUCTOR DATE DRAWN: 08/02/21 ATC JOB NO: 13704270_D3 CUSTOMER ID: CTNH568A CUSTOMER #: CTNH568A GROUNDING DETAILS 6 TIE CONNECTION DETAIL SCALE: N.T.S. SHEET NUMBER: REVISION: E-501 2 Copyright © 2022 ATC IP LLC, All Rights Reserved. PROPOSED CABLE PROPOSED CABLES www.colliersengineering.com Doing Business as C O N S U L T I N G MADISON 135 New Road Madison, CT 06443 Phone: 860.395.0055 COLLIERS ENGINEERING & DESIGN CT, P.C. DOING BUSINESS AS MASER CONSULTING Copyright © 2022. Colliers Engineering & Design All Rights Reserved. This drawing and all the information contained herein is authorized for use only by the party for whom the services were contracted or to whom it is certified. This drawing may not be copied, reused, disclosed, distributed or relied upon for any other purpose without the express written consent of Colliers Engineering & Design. REV. DESCRIPTION A PRELIM BY DATE RMD 08/02/21 0 FOR CONSTRUCTION AMN 08/06/21 1 FOR CONSTRUCTION RMD 09/01/21 2 FOR CONSTRUCTION AMN 01/03/22 ATC SITE NUMBER: 208478 ATC SITE NAME: CHESHIRE T-MOBILE SITE NAME: CTNH568A 1 PANEL SCHEDULE SITE ADDRESS: 1325 CHESHIRE STREET CHESHIRE, CT 06410 SEAL: Digitally signed by Eric Anderson Date: 2022.01.04 12:37:30-05'00' DATE DRAWN: 08/02/21 ATC JOB NO: 13704270_D3 CUSTOMER ID: CTNH568A CUSTOMER #: CTNH568A PANEL SCHEDULE SHEET NUMBER: REVISION: E-601 2 Copyright © 2022 ATC IP LLC, All Rights Reserved. Engineering & Design www.colliersengineering.com Doing Business as C O N S U L T I N G MADISON 135 New Road Madison, CT 06443 Phone: 860.395.0055 COLLIERS ENGINEERING & DESIGN CT, P.C. DOING BUSINESS AS MASER CONSULTING Copyright © 2022. Colliers Engineering & Design All Rights Reserved. This drawing and all the information contained herein is authorized for use only by the party for whom the services were contracted or to whom it is certified. This drawing may not be copied, reused, disclosed, distributed or relied upon for any other purpose without the express written consent of Colliers Engineering & Design. REV. DESCRIPTION BY DATE A PRELIM JW 07/26/21 0 FOR CONSTRUCTION AMN 08/06/21 1 FOR CONSTRUCTION RMD 09/01/21 2 FOR CONSTRUCTION AMN 01/03/22 ATC SITE NUMBER: 208478 ATC SITE NAME: CHESHIRE T-MOBILE SITE NAME: CTNH568A SITE ADDRESS: 1325 CHESHIRE STREET CHESHIRE, CT 06410 SEAL: 1 CABINET CONFIGURATION SCALE: NOT TO SCALE 2 ANTENNA CONFIGURATION SCALE: NOT TO SCALE NOTE: THIS SHEET CREATED BY OTHERS AND PROVIDED BY REQUEST OF CUSTOMER WITHOUT EDIT. DATE DRAWN: 08/02/21 ATC JOB NO: 13704270_D3 CUSTOMER ID: CTNH568A CUSTOMER #: CTNH568A SUPPLEMENTAL SHEET NUMBER: REVISION: R-601 - Copyright © 2022 ATC IP LLC, All Rights Reserved. Engineering & Design www.colliersengineering.com Doing Business as C O N S U L T I N G MADISON 135 New Road Madison, CT 06443 Phone: 860.395.0055 COLLIERS ENGINEERING & DESIGN CT, P.C. DOING BUSINESS AS MASER CONSULTING Copyright © 2022. Colliers Engineering & Design All Rights Reserved. This drawing and all the information contained herein is authorized for use only by the party for whom the services were contracted or to whom it is certified. This drawing may not be copied, reused, disclosed, distributed or relied upon for any other purpose without the express written consent of Colliers Engineering & Design. REV. DESCRIPTION BY DATE A PRELIM JW 07/26/21 0 FOR CONSTRUCTION AMN 08/06/21 1 FOR CONSTRUCTION RMD 09/01/21 2 FOR CONSTRUCTION AMN 01/03/22 ATC SITE NUMBER: 208478 ATC SITE NAME: CHESHIRE T-MOBILE SITE NAME: CTNH568A SITE ADDRESS: 1325 CHESHIRE STREET CHESHIRE, CT 06410 SEAL: 1 MOUNT ANALYSIS DATE DRAWN: 08/02/21 ATC JOB NO: 13704270_D3 CUSTOMER ID: CTNH568A CUSTOMER #: CTNH568A SUPPLEMENTAL NOTE: THIS SHEET WAS CREATED BY OTHERS AND PROVIDED AT THE REQUEST OF THE CUSTOMER WITHOUT EDIT. PLEASE REFERENCE THE MOUNT ANALYSIS REPORT FOR COMPLETE MOUNT ANALYSIS CALCULATIONS AND DETAILS. SUPPLEMENTAL PAGES INCLUDED IN THE CONSTRUCTION DRAWINGS ARE FOR REFERENCE ONLY. GENERAL CONTRACTOR IS TO VERIFY THEY HAVE THE MOST RECENT MOUNT ANALYSIS PRIOR TO CONSTRUCTION. SHEET NUMBER: REVISION: R-602 - Copyright © 2022 ATC IP LLC, All Rights Reserved. Engineering & Design NOKIA MANUFACTURER: NOKIA MANUFACTURER: NOKIA ASIB MODEL: ABIA MODEL: ABIL 6.4 LBS WEIGHT: 4.6 LBS WEIGHT: 4.4 LBS DIMENSIONS: 8.6"X14.2"X1.7" DIMENSIONS: 8.6"X14.2"X1.1" DIMENSIONS: 8.6"X14.2"X1.1" 1.7" MODEL: WEIGHT: " .2 14 Engineering & Design 8.6" EIF3 SOUT SRIO1 " .2 14 1.1" GROUNDING EIF5 EIF2 www.colliersengineering.com Doing Business as 8.6" C O N S U L T I N G MADISON EAC 135 New Road RF1 RF2 RF3 RF4 RF5 S-RF1 RF6 SFP28 Madison, CT 06443 Phone: 860.395.0055 S-RF2 COLLIERS ENGINEERING & DESIGN CT, P.C. DOING BUSINESS AS MASER CONSULTING Copyright © 2022. Colliers Engineering & Design All Rights Reserved. This drawing and all the information contained herein is authorized for use only by the party for whom the services were contracted or to whom it is certified. This drawing may not be copied, reused, disclosed, distributed or relied upon for any other purpose without the express written consent of Colliers Engineering & Design. SIN SEI1 EIF4 SEI2 LMP S-RF1 EIF1 S-RF2 QSFP28 REV. DESCRIPTION BY DATE A PRELIM JW 07/26/21 0 FOR CONSTRUCTION AMN 08/06/21 1 FOR CONSTRUCTION RMD 09/01/21 2 FOR CONSTRUCTION AMN 01/03/22 ATC SITE NUMBER: PROPOSED ASIB LOCATED WITHIN AMIA RACK 1 PROPOSED ABIA LOCATED WITHIN AMIA RACK ASIB DETAIL ATC SITE NAME: CHESHIRE ABIA DETAIL 2 SCALE: N.T.S. 208478 PROPOSED ABIL LOCATED WITHIN AMIA RACK 3 SCALE: N.T.S. ABIL DETAIL T-MOBILE SITE NAME: SCALE: N.T.S. CTNH568A MANUFACTURER: NOKIA MANUFACTURER: NOKIA MANUFACTURER: NOKIA MODEL: ABIC MODEL: ASIK MODEL: AMIA WEIGHT: 5.8 LBS WEIGHT: 6.6 LBS WEIGHT: 11.2 LBS (UNIT ONLY) DIMENSIONS: 8.6"X14.2"X1.7" DIMENSIONS: 8.6"X14.2"X1.7" DIMENSIONS: 5.1"X15.7"X17.6" SITE ADDRESS: 1325 CHESHIRE STREET CHESHIRE, CT 06410 SEAL: 1.7" " .2 14 8.6" RF2 RF6 RF4 RF8 LMP FAN RF1 RF3 RF5 RF7 STATUS SEI EIF1 EIF2 RF9 ABIC DETAIL SCALE: N.T.S. 5 08/02/21 ATC JOB NO: 13704270_D3 CUSTOMER ID: CTNH568A CUSTOMER #: CTNH568A SUPPLEMENTAL PROPOSED ASIK LOCATED WITHIN AMIA RACK 4 DATE DRAWN: ASIK DETAIL SCALE: N.T.S. 6 AMIA DETAIL SCALE: N.T.S. SHEET NUMBER: REVISION: R-603 - Copyright © 2022 ATC IP LLC, All Rights Reserved. MANUFACTURER: www.colliersengineering.com Doing Business as C O N S U L T I N G MADISON 135 New Road Madison, CT 06443 Phone: 860.395.0055 COLLIERS ENGINEERING & DESIGN CT, P.C. DOING BUSINESS AS MASER CONSULTING Copyright © 2022. Colliers Engineering & Design All Rights Reserved. This drawing and all the information contained herein is authorized for use only by the party for whom the services were contracted or to whom it is certified. This drawing may not be copied, reused, disclosed, distributed or relied upon for any other purpose without the express written consent of Colliers Engineering & Design. C A B B REV. DESCRIPTION BY DATE A PRELIM JW 07/26/21 0 FOR CONSTRUCTION AMN 08/06/21 1 FOR CONSTRUCTION RMD 09/01/21 2 FOR CONSTRUCTION AMN 01/03/22 TOP VIEW ATC SITE NUMBER: C 208478 A ATC SITE NAME: CHESHIRE T-MOBILE SITE NAME: CTNH568A TOP VIEW SITE ADDRESS: 1325 CHESHIRE STREET CHESHIRE, CT 06410 SEAL: FRONT VIEW 1 FRONT VIEW ANTENNA SPECIFICATIONS 2 FOR ILLUSTRATIVE PURPOSES ONLY - NOT TO SCALE RRU SPECIFICATIONS FOR ILLUSTRATIVE PURPOSES ONLY - NOT TO SCALE ANTENNA SPECIFICATIONS RRU SPECIFICATIONS ANTENNA MODEL A B C WEIGHT (LBS) RRU MODEL A B C WEIGHT (LBS) AIR6449 B41 33.1" 20.6" 8.6" 104.0 RADIO 4460 B25/B66 19.6" 15.7" 12.1" 109.0 APXVAALL24 43-U-NA20 95.9" 24.0" 8.5" 122.8 RADIO 4480 B71/B85A 21.8" 15.7" 7.5" 46 DATE DRAWN: 08/02/21 ATC JOB NO: 13704270_D3 CUSTOMER ID: CTNH568A CUSTOMER #: CTNH568A SUPPLEMENTAL SHEET NUMBER: REVISION: R-604 - Copyright © 2022 ATC IP LLC, All Rights Reserved. Engineering & Design www.colliersengineering.com Doing Business as C O N S U L T I N G MADISON 135 New Road Madison, CT 06443 Phone: 860.395.0055 COLLIERS ENGINEERING & DESIGN CT, P.C. DOING BUSINESS AS MASER CONSULTING Copyright © 2022. Colliers Engineering & Design All Rights Reserved. This drawing and all the information contained herein is authorized for use only by the party for whom the services were contracted or to whom it is certified. This drawing may not be copied, reused, disclosed, distributed or relied upon for any other purpose without the express written consent of Colliers Engineering & Design. REV. DESCRIPTION BY DATE A PRELIM JW 07/26/21 0 FOR CONSTRUCTION AMN 08/06/21 1 FOR CONSTRUCTION RMD 09/01/21 2 FOR CONSTRUCTION AMN 01/03/22 ATC SITE NUMBER: 208478 ATC SITE NAME: CHESHIRE T-MOBILE SITE NAME: CTNH568A SITE ADDRESS: 1325 CHESHIRE STREET CHESHIRE, CT 06410 SEAL: DATE DRAWN: 08/02/21 ATC JOB NO: 13704270_D3 CUSTOMER ID: CTNH568A CUSTOMER #: CTNH568A SUPPLEMENTAL NOTE: THIS SHEET WAS CREATED BY OTHERS AND PROVIDED AT THE REQUEST OF THE CUSTOMER WITHOUT EDIT. SHEET NUMBER: REVISION: R-605 - Copyright © 2022 ATC IP LLC, All Rights Reserved. Engineering & Design www.colliersengineering.com Doing Business as C O N S U L T I N G MADISON 135 New Road Madison, CT 06443 Phone: 860.395.0055 COLLIERS ENGINEERING & DESIGN CT, P.C. DOING BUSINESS AS MASER CONSULTING Copyright © 2022. Colliers Engineering & Design All Rights Reserved. This drawing and all the information contained herein is authorized for use only by the party for whom the services were contracted or to whom it is certified. This drawing may not be copied, reused, disclosed, distributed or relied upon for any other purpose without the express written consent of Colliers Engineering & Design. REV. DESCRIPTION BY DATE A PRELIM JW 07/26/21 0 FOR CONSTRUCTION AMN 08/06/21 1 FOR CONSTRUCTION RMD 09/01/21 2 FOR CONSTRUCTION AMN 01/03/22 ATC SITE NUMBER: 208478 ATC SITE NAME: CHESHIRE T-MOBILE SITE NAME: CTNH568A SITE ADDRESS: 1325 CHESHIRE STREET CHESHIRE, CT 06410 SEAL: DATE DRAWN: 08/02/21 ATC JOB NO: 13704270_D3 CUSTOMER ID: CTNH568A CUSTOMER #: CTNH568A SUPPLEMENTAL NOTE: THIS SHEET WAS CREATED BY OTHERS AND PROVIDED AT THE REQUEST OF THE CUSTOMER WITHOUT EDIT. SHEET NUMBER: REVISION: R-606 - Copyright © 2022 ATC IP LLC, All Rights Reserved. Engineering & Design www.colliersengineering.com Doing Business as C O N S U L T I N G MADISON 135 New Road Madison, CT 06443 Phone: 860.395.0055 COLLIERS ENGINEERING & DESIGN CT, P.C. DOING BUSINESS AS MASER CONSULTING Copyright © 2022. Colliers Engineering & Design All Rights Reserved. This drawing and all the information contained herein is authorized for use only by the party for whom the services were contracted or to whom it is certified. This drawing may not be copied, reused, disclosed, distributed or relied upon for any other purpose without the express written consent of Colliers Engineering & Design. REV. DESCRIPTION BY DATE A PRELIM JW 07/26/21 0 FOR CONSTRUCTION AMN 08/06/21 1 FOR CONSTRUCTION RMD 09/01/21 2 FOR CONSTRUCTION AMN 01/03/22 ATC SITE NUMBER: 208478 ATC SITE NAME: CHESHIRE T-MOBILE SITE NAME: CTNH568A SITE ADDRESS: 1325 CHESHIRE STREET CHESHIRE, CT 06410 SEAL: DATE DRAWN: 08/02/21 ATC JOB NO: 13704270_D3 CUSTOMER ID: CTNH568A CUSTOMER #: CTNH568A SUPPLEMENTAL SHEET NUMBER: REVISION: R-607 - Copyright © 2022 ATC IP LLC, All Rights Reserved. Engineering & Design Structural Analysis Report Structure : 170 ft Monopole ATC Site Name : Cheshire,CT ATC Site Number : 208478 Engineering Number : 13704270_C3_07 Proposed Carrier : T-MOBILE Carrier Site Name : CTNH568A Carrier Site Number : CTNH568A Site Location : 1325 Cheshire Street Cheshire, CT 06410 41.5326, -72.8705 County : New Haven Date : January 6, 2022 Max Usage : 43% Result : Pass Prepared By: Reviewed By: <<w=175; h=175; n=BLANK - SIG; a=11>> Kyle MacPetrie Structural Engineer I COA : PEC.0001553 A.T. Engineering Service, PLLC- 3500 Regency Parkway, Suite 100 - Cary, NC 27518 - 919-468-0112 Office - 919-466-5414 Fax - www.americantower.com Eng. Number 13704270_C3_07 January 6, 2022 Page. 2 Table of Contents Introduction...................................................................................................................................3 Supporting Documents ..................................................................................................................3 Analysis ..........................................................................................................................................3 Conclusion .....................................................................................................................................3 Existing and Reserved Equipment..................................................................................................4 Equipment to be Removed ............................................................................................................4 Proposed Equipment .....................................................................................................................4 Structure Usages............................................................................................................................5 Foundations ...................................................................................................................................5 Deflection and Sway* ....................................................................................................................5 Standard Conditions ......................................................................................................................6 Calculations …………………………………………………………..Attached A.T. Engineering Service, PLLC- 3500 Regency Parkway, Suite 100 - Cary, NC 27518 - 919-468-0112 Office - 919-466-5414 Fax - www.americantower.com Eng. Number 13704270_C3_07 January 6, 2022 Page. 3 Introduction The purpose of this report is to summarize results of a structural analysis performed on the 170 ft Monopole to reflect the change in loading by T-MOBILE. Supporting Documents Tower Drawings Foundation Drawing Geotechnical Report Modifications Ambor Structures Job #C15019001, dated September 21, 2015 Bennett & Pless Job #15700064, dated August 24, 2015 Terracon Project #J2145102, dated March 18, 2014 CENTEK engineering Project #21085.03, dated July 21, 2021 Analysis The tower was analyzed using American Tower Corporation’s tower analysis software. This program considers an elastic three-dimensional model and second-order effects per ANSI/TIA-222. Basic Wind Speed: Basic Wind Speed w/ Ice: Code: Exposure Category: Risk Category: Topographic Factor Procedure: Topographic Category: Crest Height (H): Spectral Response: Site Class: 118 mph (3-second gust) 50 mph (3-second gust) w/ 1.00" radial ice concurrent ANSI/TIA-222-H / 2015 IBC / 2018 Connecticut State Building Code C II Method 1 1 0 ft Ss = 0.20, S1 = 0.06 D - Stiff Soil - Default Conclusion Based on the analysis results, the structure meets the requirements per the applicable codes listed above. The tower and foundation can support the equipment as described in this report. If you have any questions or require additional information, please contact American Tower via email at Engineering@americantower.com. Please include the American Tower site name, site number, and engineering number in the subject line for any questions. A.T. Engineering Service, PLLC- 3500 Regency Parkway, Suite 100 - Cary, NC 27518 - 919-468-0112 Office - 919-466-5414 Fax - www.americantower.com Eng. Number 13704270_C3_07 January 6, 2022 Page. 4 Existing and Reserved Equipment Elev.1 (ft) Qty Equipment Mount Type Lines Carrier (4) 7/8" Coax (2) E105 CITY OF CHESHIRE, CT Sector Frame (1) 0.51" (13mm) Hybrid (1) 0.96" (24.3mm) Cable (2) 2" conduit AT&T MOBILITY Sector Frame (2) 1.25" (31.8mm) Hybrid VERIZON WIRELESS Mount Type Lines Carrier 181.2 2 RFS SC3-W100AC Stand-Off 170.0 2 dbSpectra DS1F03F36D-N Stand-Off 159.3 1 3 6 3 3 6 3 3 3 6 3 1 3 3 1 6 3 Raycap DC6-48-60-18-8C-EV Ericsson 4478 Band 14 (15" Height) Ericsson RRU22 Ericsson RRUS 12 Ericsson 8843 CCI HPA-65R-BUU-H8 CCI DMP65R-BU8D CCI TPA65R-BU8D Ericsson RRUS 4415 B30 Ericsson RRUS A2 Ericsson RRUS 4449 B5, B12 Raycap DC9-48-60-24-8C-EV Samsung B2/B66A RRH-BR049 Samsung B5/B13 RRH-BR04C RFS DB-C1-12C-24AB-0Z JMA Wireless MX10FIT665-xx Samsung RT4401-48A 155.0 145.0 Equipment to be Removed Elev.1 (ft) Qty Equipment No loading was considered as removed as part of this analysis. Proposed Equipment Elev.1 (ft) Qty 134.0 1 3 3 3 3 Equipment Ericsson Radio 4460 B25+B66 Ericsson Radio 4480 B71+B85A Ericsson Air6449 B41 RFS APXVAALL24 43-U-NA20 Mount Type Lines Triangular Platform with (3) 1.99" (50.7mm) Handrails Hybrid Carrier T-MOBILE Contracted elevations are shown for appurtenances within contracted installation tolerances. Appurtenances outside of contract limits are shown at installed elevations. Install proposed lines inside the pole shaft. A.T. Engineering Service, PLLC- 3500 Regency Parkway, Suite 100 - Cary, NC 27518 - 919-468-0112 Office - 919-466-5414 Fax - www.americantower.com Eng. Number 13704270_C3_07 January 6, 2022 Page. 5 Structure Usages Structural Component Anchor Bolts Shaft Base Plate Controlling Usage 43% 38% 20% Pass/Fail Pass Pass Pass Foundations Reaction Component Moment (Kips-Ft) Axial (Kips) Shear (Kips) Analysis Reactions 4657.1 76.4 40.5 % of Usage 42% 25% 30% The structure base reactions resulting from this analysis were found to be acceptable through analysis based on geotechnical and foundation information, therefore no modification or reinforcement of the foundation will be required. Deflection and Sway* Antenna Elevation (ft) 170.0 134.0 Antenna Carrier Deflection (ft) Twist (°) RFS SC3-W100AC RFS APXVAALL24 43-U-NA20 Ericsson Air6449 B41 Ericsson Radio 4460 B25+B66 Ericsson Radio 4480 B71+B85A CITY OF CHESHIRE, CT 1.009 N/A T-MOBILE 0.631 N/A *Deflection and Sway was evaluated considering a design wind speed of 60 mph (3-Second Gust) per ANSI/TIA-222-H A.T. Engineering Service, PLLC- 3500 Regency Parkway, Suite 100 - Cary, NC 27518 - 919-468-0112 Office - 919-466-5414 Fax - www.americantower.com Sway (Rotation) (°) 0.620 0.560 Eng. Number 13704270_C3_07 January 6, 2022 Page. 6 Standard Conditions All engineering services performed by A.T. Engineering Service, PLLC are prepared on the basis that the information used is current and correct. This information may consist of, but is not limited to the following: • Information supplied by the client regarding antenna, mounts and feed line loading • Information from drawings, design and analysis documents, and field notes in the possession of A.T. Engineering Service, PLLC It is the responsibility of the client to ensure that the information provided to A.T. Engineering Service, PLLC and used in the performance of our engineering services is correct and complete. All assets of American Tower Corporation, its affiliates, and subsidiaries (collectively “American Tower”) are inspected at regular intervals. Based upon these inspections and in the absence of information to the contrary, American Tower assumes that all structures were constructed in accordance with the drawings and specifications. Unless explicitly agreed by both the client and A.T. Engineering Service, PLLC, all services will be performed in accordance with the current revision of ANSI/TIA-222. All services are performed, results obtained, and recommendations made in accordance with generally accepted engineering principles and practices. A.T. Engineering Service, PLLC is not responsible for the conclusions, opinions and recommendations made by others based on the information supplied herein. A.T. Engineering Service, PLLC- 3500 Regency Parkway, Suite 100 - Cary, NC 27518 - 919-468-0112 Office - 919-466-5414 Fax - www.americantower.com JOB INFORMATION Asset : Client : Code : 208478, Cheshire T-MOBILE ANSI/TIA-222-H Height : Base Width : Shape : 170 ft 73.69 18 Sides SITE PARAMETERS Base Elev (ft): 0.00 Structure Class: II Taper : 0.29800 (In/ft) Exposure : C Topographic Category : 1 Topographic Feature: Topo Method : Method 1 SECTION PROPERTIES Diameter (in) Overlap Across Flats Shaft Length Thick Length Section (ft) Top Bottom (in) Joint Type (in) 1 2 3 4 5 6 38.690 38.710 38.710 38.710 38.710 9.650 62.17 54.30 46.02 37.24 28.06 27.09 73.69 65.82 57.54 48.76 39.58 29.96 0.531 0.531 0.469 0.375 0.344 0.281 Shape Steel Grade (ksi) 0.000 18 Sides Slip Joint 104.030 18 Sides Slip Joint 93.130 18 Sides Slip Joint 80.280 18 Sides Slip Joint 66.840 18 Sides Slip Joint 53.880 18 Sides DISCRETE APPURTENANCE Attach Elev (ft) Force Elev (ft) Qty 170.0 170.0 169.0 164.0 159.3 155.0 155.0 155.0 155.0 155.0 155.0 155.0 155.0 155.0 155.0 155.0 155.0 145.0 145.0 145.0 145.0 145.0 145.0 134.0 134.0 134.0 134.0 134.0 181.0 167.5 169.0 164.0 159.3 155.0 155.0 155.0 155.0 155.0 155.6 155.0 155.0 155.0 155.0 155.0 156.9 145.0 145.0 145.0 145.0 145.0 145.0 134.0 134.0 134.0 134.0 134.0 2 2 4 2 1 6 3 3 3 6 3 3 1 6 3 3 3 3 3 3 1 6 3 3 3 3 3 1 Description dbSpectra DS1F03F36D-N RFS SC3-W100AC Generic Flat Stand-Off Generic Flat Stand-Off Raycap DC6-48-60-18-8C-EV Ericsson RRUS A2 Ericsson 4478 Band 14 (15" Hei Ericsson RRUS 4415 B30 Ericsson RRUS 4449 B5, B12 Ericsson RRU22 Ericsson RRUS 12 Ericsson 8843 Raycap DC9-48-60-24-8C-EV CCI HPA-65R-BUU-H8 Generic Round Sector Frame CCI DMP65R-BU8D CCI TPA65R-BU8D Samsung RT4401-48A Samsung B5/B13 RRH-BR04C Samsung B2/B66A RRH-BR049 RFS DB-C1-12C-24AB-0Z JMA Wireless MX10FIT665-xx Generic Flat Light Sector Fram Ericsson Radio 4460 B25+B66 Ericsson Radio 4480 B71+B85A Ericsson Air6449 B41 RFS APXVAALL24 43-U-NA20 Generic Flat Platform with Han LINEAR APPURTENANCE Elev From (ft) Elev To (ft) 0.0 0.0 0.0 0.0 0.0 0.0 0.0 170.0 170.0 155.0 155.0 155.0 145.0 134.0 1.2D + 1.0W © 2007 - 2020 by ATC LLC. All rights reserved. Page 1 of 2 Description Exp To Wind E105 7/8" Coax 2" conduit 0.96" (24.3mm) Cable 0.51" (13mm) Hybrid 1.25" (31.8mm) Hybrid 1.99" (50.7mm) Hybrid No No No No No No No LOAD CASES 118 mph wind with no ice Model ID : 5070 1/6/2022 13:26:48 65 65 65 65 65 65 JOB INFORMATION Asset : Client : Code : 208478, Cheshire T-MOBILE ANSI/TIA-222-H Height : Base Width : Shape : 0.9D + 1.0W 1.2D + 1.0Di + 1.0Wi 1.2D + 1.0Ev + 1.0Eh 0.9D - 1.0Ev + 1.0Eh 1.0D + 1.0W Load Case 118 mph wind with no ice 50 mph wind with 1" radial ice Seismic Seismic (Reduced DL) 60 mph Wind with No Ice REACTIONS Moment (kip-ft) Shear (Kip) Axial (Kip) 4657.08 4630.59 1240.75 270.21 268.37 1073.38 40.45 40.43 11.10 2.19 2.19 9.35 76.44 57.32 95.44 76.49 52.77 63.72 1.2D + 1.0W 0.9D + 1.0W 1.2D + 1.0Di + 1.0Wi 1.2D + 1.0Ev + 1.0Eh 0.9D - 1.0Ev + 1.0Eh 1.0D + 1.0W Load Case 1.0D + 1.0W © 2007 - 2020 by ATC LLC. All rights reserved. Page 2 of 2 170 ft 73.69 18 Sides DISH DEFLECTIONS Attach Deflection Elev (ft) (in) 170.00 Model ID : 5070 12.109 1/6/2022 13:26:48 Rotation (deg) 0.621 ASSET: 208478, Cheshire CODE: ANSI/TIA-222-H CUSTOMER: T-MOBILE ENG NO: 13704270_C3_07 ANALYSIS PARAMETERS Location: New Haven County,CT Height: 170 ft Type and Shape: Taper, 18 Sides Base Diameter: 73.69 in Manufacturer: Undetermined Top Diameter: 27.09 in Kd (non-service): 0.95 Taper: 0.2980 in/ft Ke: 1.00 Rotation: 0.000o ICE & WIND PARAMETERS Exposure Category: C Design Wind Speed w/o Ice: 118 mph Risk Category: II Design Wind Speed w/Ice: 50 mph Topo Factor Procedure: Method 1 Operational Wind Speed: 60 mph Topographic Category: 1 Design Ice Thickness: 1.00 in Crest Height: 0 ft HMSL: 116.00 ft SEISMIC PARAMETERS Analysis Method: Equivalent Lateral Force Method Site Class: D - Stiff Soil TL (sec): 6 P: 1 Cs: 0.034 Ss: 0.200 S1: 0.055 Cs Max: 0.034 Fa: 1.600 Fv: 2.400 Cs Min: 0.030 Sds: 0.213 Sd1: 0.088 Period Based on Rayleigh Method (sec): 1.71 LOAD CASES 1.2D + 1.0W 0.9D + 1.0W 1.2D + 1.0Di + 1.0Wi 1.2D + 1.0Ev + 1.0Eh 0.9D - 1.0Ev + 1.0Eh 1.0D + 1.0W ©2007 - 2020 by ATC LLC. All rights reserved. 118 mph wind with no ice 118 mph wind with no ice 50 mph wind with 1" radial ice Seismic Seismic (Reduced DL) 60 mph Wind with No Ice Page 1 of 13 Model Id : 5070 Scenario Id: 189274 1/6/2022 13:26:53 ASSET: 208478, Cheshire CODE: ANSI/TIA-222-H CUSTOMER: T-MOBILE ENG NO: 13704270_C3_07 SHAFT SECTION PROPERTIES . Bottom Sect Info Length (ft) 1-18 Thick Fy Joint (in) (ksi) Type 38.69 0.5313 65 Slip Joint Weight len (in) (lb) Dia (in) Elev Area (ft) (in2) 123.3 7 110.0 13,220 65.82 30.020 9 10,056 57.54 60.970 84.92 6,683 48.76 92.990 57.59 126.13 4,812 39.58 0 42.82 160.35 828 29.96 0 26.50 0.00 14,962 73.69 0.000 2-18 3-18 4-18 38.71 0.5313 38.71 0.4688 38.71 0.3750 65 65 65 Slip Slip Slip 104.03 93.13 80.28 5-18 38.71 0.3438 65 Slip 66.84 6-18 9.65 0.2813 65 Slip 53.88 Ix (in4) W/t Ratio D/t Ratio Top Dia (in) Elev Area (in) (in2) 83,422.3 22.69 138.70 62.17 38.69 103.95 Ix (in4) W/t Ratio D/t Taper Ratio (in/ft) 49,903.5 18.87 117.02 0.2976 33,109.7 59,284.2 20.08 123.88 54.30 68.73 90.66 34,949.6 19.88 122.74 46.02 99.68 67.78 17,768.5 17,035.7 21.16 130.03 37.24 131.70 43.88 7,533.9 2,936.5 8,331.0 18.54 115.14 28.06 164.84 30.25 2,173.5 2,949.6 17.02 106.51 27.09 170.00 23.94 16.26 102.19 0.2976 15.55 98.17 0.2976 15.75 99.31 0.2976 12.63 81.63 0.2976 15.22 96.30 0.2976 Shaft Weight 50,561 DISCRETE APPURTENANCE PROPERTIES Attach Elev (ft) Description 170.00 170.00 169.00 164.00 159.30 155.00 155.00 155.00 155.00 155.00 155.00 155.00 155.00 155.00 155.00 155.00 155.00 145.00 145.00 145.00 145.00 145.00 145.00 134.00 134.00 134.00 134.00 134.00 dbSpectra DS1F03F36D-N RFS SC3-W100AC Generic Flat Stand-Off Generic Flat Stand-Off Raycap DC6-48-60-18-8C-EV Ericsson 4478 Band 14 (15" Hei CCI TPA65R-BU8D CCI DMP65R-BU8D Generic Round Sector Frame CCI HPA-65R-BUU-H8 Raycap DC9-48-60-24-8C-EV Ericsson 8843 Ericsson RRUS 12 Ericsson RRU22 Ericsson RRUS 4449 B5, B12 Ericsson RRUS 4415 B30 Ericsson RRUS A2 Generic Flat Light Sector Fram Samsung B2/B66A RRH-BR049 Samsung B5/B13 RRH-BR04C RFS DB-C1-12C-24AB-0Z JMA Wireless MX10FIT665-xx Samsung RT4401-48A Ericsson Air6449 B41 Ericsson Radio 4480 B71+B85A Generic Flat Platform with Han Ericsson Radio 4460 B25+B66 RFS APXVAALL24 43-U-NA20 Totals Num Loadings: 28 Qty Ka Vert Ecc (ft) 2 2 4 2 1 3 3 3 3 6 1 3 3 6 3 3 6 3 3 3 1 6 3 3 3 1 3 3 1.00 1.00 1.00 1.00 0.80 0.80 0.80 0.80 0.75 0.80 0.80 0.80 0.80 0.80 0.80 0.80 0.80 0.75 0.80 0.80 0.80 0.80 0.80 0.75 0.75 1.00 0.75 0.75 11.000 -2.500 0.000 0.000 0.000 0.000 1.900 0.000 0.000 0.000 0.000 0.000 0.600 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 86 . Weight (lb) 71.00 40.00 187.50 187.50 16.00 59.90 82.50 95.70 300.00 68.00 16.00 85.00 50.00 52.90 71.00 46.00 15.00 400.00 84.40 70.30 32.00 53.40 18.60 104.00 84.00 2500.00 109.00 122.80 No Ice . EPAa Orientation (sf) Factor 6.750 10.737 6.300 6.300 4.788 1.842 18.089 17.871 14.400 12.976 4.788 3.500 3.145 2.222 1.969 1.842 1.600 17.900 1.875 1.875 4.056 8.092 0.996 5.682 2.852 42.400 2.564 20.243 . 1.00 1.00 0.67 0.90 0.50 0.50 0.63 0.63 0.67 0.67 0.50 0.50 0.50 0.50 0.50 0.50 0.50 0.75 0.50 0.50 1.00 0.69 0.50 0.63 0.50 1.00 0.50 0.63 10,396.40 Weight (lb) Ice EPAa (sf) . Orientation Factor 185.26 187.52 277.47 277.20 102.67 96.90 313.21 323.13 546.13 239.93 102.39 153.27 104.12 93.56 114.13 78.81 39.29 600.02 126.80 108.32 116.47 171.93 36.55 193.94 133.86 3672.42 167.33 379.86 12.127 12.032 8.404 8.398 5.775 2.442 20.560 20.337 25.476 15.371 5.772 4.355 3.921 2.890 2.593 2.442 2.159 27.928 2.475 2.475 4.963 9.913 1.451 6.730 3.589 56.241 3.260 22.691 1.00 1.00 0.67 0.90 0.50 0.50 0.63 0.63 0.67 0.67 0.50 0.50 0.50 0.50 0.50 0.50 0.50 0.75 0.50 0.50 1.00 0.69 0.50 0.63 0.50 1.00 0.50 0.63 20,101.19 LINEAR APPURTENANCE PROPERTIES Load Case Azimuth (deg) : 0.00 Elev From (ft) 0.00 0.00 0.00 0.00 0.00 0.00 0.00 Elev To (ft) Qty Description 170.00 170.00 155.00 155.00 155.00 145.00 134.00 4 2 2 1 1 2 3 7/8" Coax E105 2" conduit 0.51" (13mm) Hybrid 0.96" (24.3mm) Cable 1.25" (31.8mm) Hybrid 1.99" (50.7mm) Hybrid ©2007 - 2020 by ATC LLC. All rights reserved. Coax Dia (in) Coax Wt (lb/ft) 1.09 1.3 2.38 0.51 0.96 1.25 1.99 0.33 0.4 3.65 0.14 0.88 1.21 1.9 Flat Max Coax/ Row Dist Between Rows(in) Dist Between Cols(in) Azimuth (deg) N N N N N N N 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 Page 2 of 13 Model Id : 5070 Dist From Face Exposed (in) To Wind Carrier 0 0 0 0 0 0 0 N N N N N N N Scenario Id: 189274 CITY OF CHESH CITY OF CHESH AT&T MOBILITY AT&T MOBILITY AT&T MOBILITY VERIZON WIREL T-MOBILE 1/6/2022 13:26:53 ASSET: 208478, Cheshire CODE: ANSI/TIA-222-H CUSTOMER: T-MOBILE ENG NO: 13704270_C3_07 SEGMENT PROPERTIES (Max Len: Seg Top Elev (ft) 0.00 5.00 10.00 15.00 20.00 25.00 30.00 30.02 35.00 38.69 40.00 45.00 50.00 55.00 60.00 60.97 65.00 68.73 70.00 75.00 80.00 85.00 90.00 92.99 95.00 99.68 100.00 105.00 110.00 115.00 120.00 125.00 126.13 130.00 131.70 134.00 135.00 140.00 145.00 150.00 155.00 159.30 160.00 160.35 164.00 164.84 165.00 169.00 170.00 Description Bot - Section 2 Top - Section 1 Bot - Section 3 Top - Section 2 Bot - Section 4 Top - Section 3 Bot - Section 5 Top - Section 4 Bot - Section 6 Top - Section 5 5.ft) . Thick (in) Flat Dia (in) Area (in2) Ix (in4) W/t Ratio 0.5313 0.5313 0.5313 0.5313 0.5313 0.5313 0.5313 0.5313 0.5313 0.5313 0.5313 0.5313 0.5313 0.5313 0.5313 0.5313 0.5313 0.4688 0.4688 0.4688 0.4688 0.4688 0.4688 0.4688 0.4688 0.3750 0.3750 0.3750 0.3750 0.3750 0.3750 0.3750 0.3750 0.3750 0.3438 0.3438 0.3438 0.3438 0.3438 0.3438 0.3438 0.3438 0.3438 0.3438 0.3438 0.2813 0.2813 0.2813 0.2813 73.690 72.202 70.714 69.225 67.737 66.249 64.761 64.754 63.272 63.237 62.847 61.359 59.870 58.382 56.894 56.605 55.406 55.233 54.855 53.367 51.879 50.390 48.902 48.012 47.414 46.771 46.676 45.187 43.699 42.211 40.723 39.234 38.898 37.746 37.928 37.243 36.946 35.457 33.969 32.481 30.993 29.713 29.504 29.400 28.314 28.626 28.579 27.388 27.091 123.366 120.857 118.347 115.838 113.328 110.819 108.309 108.299 105.799 105.739 105.082 102.572 100.062 97.553 95.043 94.556 92.534 81.484 80.922 78.708 76.493 74.279 72.065 70.740 69.850 55.220 55.107 53.336 51.565 49.793 48.022 46.251 45.850 44.479 41.011 40.264 39.939 38.315 36.691 35.067 33.443 32.047 31.820 31.706 30.520 25.307 25.264 24.201 23.936 83,422.30 78,434.10 73,648.80 69,062.30 64,670.20 60,468.40 56,452.60 56,436.30 52,618.70 52,528.90 51,555.10 47,948.80 44,514.80 41,248.80 38,146.60 37,563.10 35,203.90 30,875.60 30,241.10 27,825.80 25,542.70 23,388.10 21,358.10 20,202.10 19,449.10 15,017.90 14,925.70 13,532.20 12,228.30 11,010.90 9,877.10 8,824.00 8,596.80 7,848.50 7,319.10 6,926.40 6,760.10 5,968.60 5,241.40 4,575.80 3,969.10 3,492.30 3,418.50 3,382.00 3,016.70 2,568.90 2,556.00 2,246.70 2,173.50 22.69 22.20 21.71 21.21 20.72 20.22 19.73 19.73 19.24 19.22 19.09 18.60 18.11 17.61 17.12 17.02 16.62 19.01 18.87 18.31 17.75 17.19 16.63 16.30 16.07 20.23 20.18 19.48 18.78 18.08 17.38 16.68 16.53 15.99 17.69 17.34 17.19 16.42 15.66 14.90 14.13 13.48 13.37 13.32 12.76 16.18 16.15 15.40 15.22 D/t F'y Ratio (ksi) 138.70 135.90 133.10 130.29 127.49 124.69 121.89 121.88 119.09 119.02 118.29 115.49 112.69 109.89 107.08 106.54 104.28 117.82 117.01 113.84 110.66 107.49 104.31 102.41 101.14 124.72 124.47 120.50 116.53 112.56 108.59 104.63 103.73 100.66 110.32 108.33 107.46 103.13 98.80 94.48 90.15 86.42 85.82 85.52 82.36 101.76 101.60 97.36 96.30 74.7 75.3 75.9 76.5 77 77.6 78.2 78.2 78.8 78.8 78.9 79.5 80.1 80.7 81.3 81.4 81.8 79 79.2 79.9 80.5 81.2 81.8 82.2 82.5 77.6 77.7 78.5 79.3 80.1 81 81.8 82 82.6 80.6 81 81.2 82.1 82.6 82.6 82.6 82.6 82.6 82.6 82.6 82.4 82.4 82.6 82.6 S (in3) 2229.7 2139.6 2051.4 1965.0 1880.4 1797.8 1716.9 1716.6 1638.0 1636.1 1615.7 1539.2 1464.5 1391.6 1320.6 1307.0 1251.5 1101.0 1085.8 1027.0 969.8 914.2 860.2 828.8 807.9 632.4 629.8 589.8 551.2 513.8 477.7 443.0 435.3 409.5 380.1 366.3 360.4 331.6 303.9 277.5 252.2 231.5 228.2 226.6 209.9 176.8 176.2 161.6 158.0 Totals: ©2007 - 2020 by ATC LLC. All rights reserved. Page 3 of 13 Model Id : 5070 Z Weight (in3) (lb) 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 2,077.6 2,034.9 1,992.2 1,949.5 1,906.8 1,864.1 7.7 3,657.8 2,656.1 469.9 1,766.5 1,723.8 1,681.1 1,638.4 313.0 2,434.9 2,207.8 350.7 1,358.0 1,320.3 1,282.6 1,244.9 726.6 872.1 1,988.6 60.0 922.5 892.4 862.2 832.1 802.0 177.1 1,150.4 494.5 318.0 136.5 665.7 638.1 610.4 582.8 479.1 76.1 37.9 709.4 159.5 13.8 336.6 81.9 50,564.9 Scenario Id: 189274 1/6/2022 13:26:53 ASSET: 208478, Cheshire CODE: ANSI/TIA-222-H CUSTOMER: T-MOBILE ENG NO: 13704270_C3_07 Load Case: 1.2D + 1.0W Gust Response Factor: Dead load Factor: Wind Load Factor: 118 mph wind with no ice 21 Iterations 1.10 1.20 1.00 CALCULATED FORCES Seg Elev (ft) Pu FY (-) (kips) Vu FX (-) (kips) 0.00 5.00 10.00 15.00 20.00 25.00 30.00 30.02 35.00 38.69 40.00 45.00 50.00 55.00 60.00 60.97 65.00 68.73 70.00 75.00 80.00 85.00 90.00 92.99 95.00 99.68 100.00 105.00 110.00 115.00 120.00 125.00 126.13 130.00 131.70 134.00 135.00 140.00 145.00 150.00 155.00 159.30 160.00 160.35 164.00 164.84 165.00 169.00 170.00 -76.44 -73.78 -71.18 -68.62 -66.12 -63.67 -61.30 -61.27 -56.72 -53.43 -52.81 -50.54 -48.32 -46.15 -44.05 -43.64 -40.60 -37.85 -37.38 -35.60 -33.87 -32.19 -30.56 -29.61 -28.50 -26.00 -25.90 -24.65 -23.45 -22.28 -21.15 -20.07 -19.82 -18.35 -17.72 -12.96 -12.78 -11.91 -8.75 -7.97 -3.73 -3.14 -3.05 -3.01 -1.74 -1.55 -1.54 -0.28 0.00 -40.45 -39.84 -39.25 -38.65 -38.04 -37.40 -37.06 -36.73 -36.12 -35.75 -35.32 -34.61 -33.91 -33.20 -32.76 -32.41 -31.83 -31.43 -31.00 -30.30 -29.60 -28.91 -28.35 -28.00 -27.54 -27.15 -26.82 -26.17 -25.52 -24.89 -24.28 -23.88 -23.59 -23.22 -22.97 -18.32 -17.99 -17.41 -13.39 -12.85 -4.79 -4.42 -4.37 -4.18 -3.32 -3.26 -3.07 -1.90 -1.89 Tu MY (ft-kips) 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 Mu MZ (ft-kips) Mu MX (ft-kips) Resultant Moment (ft-kips) Phi Pn (kips) Phi Vn (kips) Phi Tn (ft-kips) Phi Mn (ft-kips) Total Deflect (in) Rotation (deg) Ratio -4,657.1 -4,454.8 -4,255.6 -4,059.4 -3,866.2 -3,676.0 -3,489.0 -3,488.2 -3,305.3 -3,172.0 -3,125.2 -2,948.6 -2,775.6 -2,606.0 -2,440.0 -2,408.2 -2,277.6 -2,158.9 -2,119.0 -1,964.0 -1,812.5 -1,664.5 -1,520.0 -1,435.2 -1,379.0 -1,250.0 -1,241.4 -1,107.3 -976.5 -848.8 -724.4 -603.0 -576.0 -484.7 -445.2 -392.4 -374.1 -284.1 -197.1 -130.1 -63.0 -42.5 -39.4 -37.8 -22.6 -19.8 -19.3 -7.0 -5.1 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 4,657.08 4,454.85 4,255.64 4,059.40 3,866.15 3,675.98 3,488.99 3,488.22 3,305.32 3,172.04 3,125.21 2,948.62 2,775.55 2,606.02 2,440.03 2,408.24 2,277.63 2,158.89 2,119.00 1,963.99 1,812.51 1,664.52 1,520.00 1,435.23 1,378.96 1,250.04 1,241.37 1,107.28 976.46 848.84 724.38 603.00 576.01 484.71 445.23 392.41 374.09 284.14 197.08 130.11 63.05 42.46 39.36 37.83 22.58 19.80 19.28 6.99 5.09 8,295.02 8,189.47 8,081.29 7,970.49 7,857.06 7,741.01 7,622.33 7,621.83 7,501.03 7,498.09 7,465.86 7,341.18 7,213.88 7,083.96 6,951.42 6,925.39 6,816.24 5,796.47 5,768.66 5,657.44 5,543.60 5,427.13 5,308.04 5,235.56 5,186.33 3,857.01 3,851.71 3,767.41 3,680.49 3,590.95 3,498.78 3,403.98 3,382.19 3,304.60 2,974.75 2,935.54 2,918.31 2,830.61 2,725.98 2,605.33 2,484.68 2,380.92 2,364.03 2,355.57 2,267.51 1,876.06 1,873.71 1,798.04 1,778.30 2,165.08 2,121.04 2,076.99 2,032.95 1,988.91 1,944.87 1,900.82 1,900.64 1,856.78 1,855.72 1,844.18 1,800.14 1,756.10 1,712.05 1,668.01 1,659.46 1,623.97 1,430.05 1,420.18 1,381.32 1,342.46 1,303.60 1,264.74 1,241.49 1,225.87 969.12 967.13 936.05 904.96 873.87 842.79 811.70 804.67 780.61 719.74 706.63 700.93 672.43 643.93 615.43 586.93 562.42 558.43 556.43 535.63 444.14 443.39 424.73 420.07 14,306.35 13,730.28 13,166.04 12,613.65 12,073.09 11,544.37 11,027.49 11,025.36 10,522.45 10,510.47 10,380.18 9,890.36 9,412.38 8,946.23 8,491.93 8,405.13 8,049.46 7,073.77 6,976.53 6,599.99 6,233.89 5,878.24 5,533.04 5,331.57 5,198.28 4,061.20 4,044.57 3,788.77 3,541.33 3,302.24 3,071.51 2,849.13 2,800.03 2,635.11 2,443.38 2,355.21 2,317.37 2,132.78 1,955.84 1,786.57 1,624.96 1,492.10 1,471.01 1,460.51 1,353.36 1,137.15 1,133.33 1,039.99 1,017.28 12,493.79 12,082.08 11,673.09 11,267.07 10,864.26 10,464.90 10,069.24 10,067.60 9,677.52 9,668.17 9,566.25 9,179.95 8,798.15 8,421.09 8,049.01 7,977.39 7,682.15 6,526.94 6,450.44 6,151.49 5,856.63 5,566.11 5,280.17 5,111.44 4,999.05 3,681.17 3,668.51 3,471.96 3,278.28 3,087.70 2,900.48 2,716.85 2,675.87 2,535.56 2,297.47 2,225.52 2,194.45 2,041.16 1,881.59 1,717.91 1,561.69 1,433.29 1,412.90 1,402.75 1,299.24 1,091.91 1,088.70 1,000.34 978.39 0 0.04 0.17 0.37 0.67 1.05 1.51 1.51 2.07 2.54 2.71 3.45 4.27 5.19 6.19 6.4 7.29 8.17 8.48 9.77 11.16 12.65 14.24 15.24 15.94 17.61 17.73 19.64 21.66 23.8 26.04 28.39 28.93 30.83 31.68 32.85 33.37 35.98 38.66 41.39 44.16 46.56 46.95 47.15 49.2 49.67 49.76 52.01 52.58 0 -0.08 -0.16 -0.24 -0.32 -0.4 -0.49 -0.49 -0.57 -0.64 -0.66 -0.74 -0.83 -0.91 -1 -1.02 -1.09 -1.16 -1.18 -1.28 -1.37 -1.47 -1.57 -1.63 -1.67 -1.76 -1.76 -1.87 -1.98 -2.09 -2.19 -2.29 -2.31 -2.38 -2.4 -2.44 -2.46 -2.53 -2.58 -2.63 -2.66 -2.67 -2.68 -2.68 -2.69 -2.69 -2.69 -2.7 -2.7 0.382 0.378 0.374 0.369 0.365 0.360 0.355 0.355 0.349 0.336 0.334 0.328 0.323 0.316 0.310 0.309 0.303 0.338 0.335 0.326 0.316 0.305 0.294 0.287 0.282 0.347 0.346 0.326 0.305 0.282 0.257 0.229 0.222 0.198 0.201 0.181 0.176 0.144 0.108 0.079 0.042 0.031 0.029 0.028 0.018 0.019 0.019 0.007 0.005 ©2007 - 2020 by ATC LLC. All rights reserved. Page 4 of 13 Model Id : 5070 Scenario Id: 189274 1/6/2022 13:26:53 ASSET: 208478, Cheshire CODE: ANSI/TIA-222-H CUSTOMER: T-MOBILE ENG NO: 13704270_C3_07 Load Case: 0.9D + 1.0W Gust Response Factor: Dead load Factor: Wind Load Factor: 118 mph wind with no ice 21 Iterations 1.10 0.90 1.00 CALCULATED FORCES Seg Elev (ft) Pu FY (-) (kips) Vu FX (-) (kips) 0.00 5.00 10.00 15.00 20.00 25.00 30.00 30.02 35.00 38.69 40.00 45.00 50.00 55.00 60.00 60.97 65.00 68.73 70.00 75.00 80.00 85.00 90.00 92.99 95.00 99.68 100.00 105.00 110.00 115.00 120.00 125.00 126.13 130.00 131.70 134.00 135.00 140.00 145.00 150.00 155.00 159.30 160.00 160.35 164.00 164.84 165.00 169.00 170.00 -57.32 -55.32 -53.35 -51.42 -49.53 -47.68 -45.90 -45.87 -42.45 -39.98 -39.50 -37.79 -36.12 -34.48 -32.90 -32.59 -30.30 -28.23 -27.87 -26.53 -25.23 -23.96 -22.74 -22.02 -21.18 -19.30 -19.23 -18.28 -17.37 -16.49 -15.64 -14.83 -14.64 -13.54 -13.06 -9.54 -9.40 -8.75 -6.42 -5.84 -2.74 -2.31 -2.24 -2.21 -1.27 -1.12 -1.12 -0.19 0.00 -40.43 -39.80 -39.19 -38.57 -37.93 -37.27 -36.93 -36.59 -35.97 -35.60 -35.15 -34.44 -33.72 -33.00 -32.56 -32.21 -31.62 -31.23 -30.79 -30.08 -29.38 -28.68 -28.12 -27.78 -27.32 -26.94 -26.60 -25.95 -25.30 -24.67 -24.05 -23.67 -23.38 -23.01 -22.77 -18.17 -17.84 -17.27 -13.29 -12.75 -4.74 -4.38 -4.33 -4.14 -3.29 -3.24 -3.05 -1.90 -1.89 Tu MY (ft-kips) 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 Mu MZ (ft-kips) Mu MX (ft-kips) Resultant Moment (ft-kips) Phi Pn (kips) Phi Vn (kips) Phi Tn (ft-kips) Phi Mn (ft-kips) Total Deflect (in) Rotation (deg) Ratio -4,630.6 -4,428.4 -4,229.4 -4,033.5 -3,840.7 -3,651.0 -3,464.7 -3,463.9 -3,281.7 -3,149.0 -3,102.4 -2,926.6 -2,754.4 -2,585.9 -2,420.9 -2,389.3 -2,259.5 -2,141.5 -2,101.9 -1,947.9 -1,797.5 -1,650.6 -1,507.2 -1,423.1 -1,367.3 -1,239.4 -1,230.8 -1,097.8 -968.1 -841.6 -718.2 -597.9 -571.2 -480.7 -441.6 -389.2 -371.1 -281.9 -195.6 -129.1 -62.6 -42.2 -39.1 -37.6 -22.5 -19.7 -19.2 -7.0 -5.1 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 4,630.59 4,428.42 4,229.41 4,033.49 3,840.66 3,651.02 3,464.67 3,463.90 3,281.72 3,149.01 3,102.38 2,926.62 2,754.44 2,585.86 2,420.87 2,389.27 2,259.50 2,141.53 2,101.89 1,947.92 1,797.51 1,650.62 1,507.22 1,423.11 1,367.29 1,239.42 1,230.81 1,097.81 968.08 841.57 718.22 597.94 571.20 480.73 441.60 389.25 371.07 281.89 195.55 129.12 62.56 42.17 39.10 37.58 22.48 19.71 19.19 6.99 5.09 8,295.02 8,189.47 8,081.29 7,970.49 7,857.06 7,741.01 7,622.33 7,621.83 7,501.03 7,498.09 7,465.86 7,341.18 7,213.88 7,083.96 6,951.42 6,925.39 6,816.24 5,796.47 5,768.66 5,657.44 5,543.60 5,427.13 5,308.04 5,235.56 5,186.33 3,857.01 3,851.71 3,767.41 3,680.49 3,590.95 3,498.78 3,403.98 3,382.19 3,304.60 2,974.75 2,935.54 2,918.31 2,830.61 2,725.98 2,605.33 2,484.68 2,380.92 2,364.03 2,355.57 2,267.51 1,876.06 1,873.71 1,798.04 1,778.30 2,165.08 2,121.04 2,076.99 2,032.95 1,988.91 1,944.87 1,900.82 1,900.64 1,856.78 1,855.72 1,844.18 1,800.14 1,756.10 1,712.05 1,668.01 1,659.46 1,623.97 1,430.05 1,420.18 1,381.32 1,342.46 1,303.60 1,264.74 1,241.49 1,225.87 969.12 967.13 936.05 904.96 873.87 842.79 811.70 804.67 780.61 719.74 706.63 700.93 672.43 643.93 615.43 586.93 562.42 558.43 556.43 535.63 444.14 443.39 424.73 420.07 14,306.35 13,730.28 13,166.04 12,613.65 12,073.09 11,544.37 11,027.49 11,025.36 10,522.45 10,510.47 10,380.18 9,890.36 9,412.38 8,946.23 8,491.93 8,405.13 8,049.46 7,073.77 6,976.53 6,599.99 6,233.89 5,878.24 5,533.04 5,331.57 5,198.28 4,061.20 4,044.57 3,788.77 3,541.33 3,302.24 3,071.51 2,849.13 2,800.03 2,635.11 2,443.38 2,355.21 2,317.37 2,132.78 1,955.84 1,786.57 1,624.96 1,492.10 1,471.01 1,460.51 1,353.36 1,137.15 1,133.33 1,039.99 1,017.28 12,493.79 12,082.08 11,673.09 11,267.07 10,864.26 10,464.90 10,069.24 10,067.60 9,677.52 9,668.17 9,566.25 9,179.95 8,798.15 8,421.09 8,049.01 7,977.39 7,682.15 6,526.94 6,450.44 6,151.49 5,856.63 5,566.11 5,280.17 5,111.44 4,999.05 3,681.17 3,668.51 3,471.96 3,278.28 3,087.70 2,900.48 2,716.85 2,675.87 2,535.56 2,297.47 2,225.52 2,194.45 2,041.16 1,881.59 1,717.91 1,561.69 1,433.29 1,412.90 1,402.75 1,299.24 1,091.91 1,088.70 1,000.34 978.39 0 0.04 0.17 0.37 0.66 1.04 1.5 1.51 2.05 2.52 2.7 3.43 4.25 5.16 6.15 6.36 7.24 8.12 8.42 9.7 11.08 12.56 14.14 15.14 15.83 17.49 17.61 19.5 21.51 23.63 25.85 28.18 28.72 30.61 31.45 32.61 33.12 35.71 38.37 41.08 43.83 46.21 46.6 46.8 48.83 49.3 49.39 51.63 52.19 0 -0.08 -0.16 -0.24 -0.32 -0.4 -0.48 -0.48 -0.57 -0.63 -0.66 -0.74 -0.82 -0.91 -0.99 -1.01 -1.08 -1.15 -1.17 -1.27 -1.36 -1.46 -1.56 -1.61 -1.65 -1.74 -1.75 -1.86 -1.97 -2.07 -2.17 -2.27 -2.29 -2.36 -2.39 -2.42 -2.44 -2.51 -2.56 -2.61 -2.64 -2.65 -2.66 -2.66 -2.67 -2.67 -2.67 -2.67 -2.67 0.378 0.374 0.369 0.365 0.360 0.355 0.350 0.350 0.345 0.331 0.330 0.324 0.318 0.312 0.306 0.305 0.299 0.333 0.331 0.322 0.312 0.301 0.290 0.283 0.278 0.342 0.341 0.322 0.301 0.278 0.253 0.225 0.219 0.195 0.198 0.179 0.173 0.142 0.107 0.078 0.041 0.030 0.029 0.028 0.018 0.019 0.018 0.007 0.005 ©2007 - 2020 by ATC LLC. All rights reserved. Page 5 of 13 Model Id : 5070 Scenario Id: 189274 1/6/2022 13:26:53 ASSET: 208478, Cheshire CODE: ANSI/TIA-222-H CUSTOMER: T-MOBILE ENG NO: 13704270_C3_07 Load Case: 1.2D + 1.0Di + 1.0Wi Gust Response Factor: 1.10 Dead load Factor: 1.20 Wind Load Factor: 1.00 50 mph wind with 1" radial ice Ice Dead Load Factor 1.00 21 Iterations Ice Importance Factor 1.00 CALCULATED FORCES Seg Elev (ft) Pu FY (-) (kips) Vu FX (-) (kips) 0.00 5.00 10.00 15.00 20.00 25.00 30.00 30.02 35.00 38.69 40.00 45.00 50.00 55.00 60.00 60.97 65.00 68.73 70.00 75.00 80.00 85.00 90.00 92.99 95.00 99.68 100.00 105.00 110.00 115.00 120.00 125.00 126.13 130.00 131.70 134.00 135.00 140.00 145.00 150.00 155.00 159.30 160.00 160.35 164.00 164.84 165.00 169.00 170.00 -95.44 -92.48 -89.54 -86.63 -83.77 -80.96 -78.21 -78.20 -73.29 -69.72 -69.01 -66.38 -63.80 -61.28 -58.82 -58.34 -55.02 -52.00 -51.46 -49.35 -47.29 -45.28 -43.33 -42.19 -40.96 -38.15 -38.05 -36.51 -35.01 -33.55 -32.14 -30.78 -30.48 -28.79 -28.07 -21.02 -20.79 -19.65 -14.75 -13.71 -5.49 -4.63 -4.50 -4.44 -2.83 -2.60 -2.58 -0.82 0.00 -11.10 -10.92 -10.74 -10.57 -10.38 -10.19 -10.09 -9.99 -9.81 -9.70 -9.57 -9.36 -9.14 -8.93 -8.80 -8.69 -8.52 -8.40 -8.27 -8.05 -7.84 -7.63 -7.46 -7.35 -7.22 -7.10 -7.00 -6.80 -6.60 -6.40 -6.21 -6.09 -6.00 -5.89 -5.81 -4.73 -4.63 -4.44 -3.39 -3.22 -1.28 -1.17 -1.15 -1.09 -0.87 -0.85 -0.79 -0.48 -0.47 Tu MY (ft-kips) 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 Mu MZ (ft-kips) Mu MX (ft-kips) Resultant Moment (ft-kips) Phi Pn (kips) Phi Vn (kips) Phi Tn (ft-kips) Phi Mn (ft-kips) Total Deflect (in) Rotation (deg) Ratio -1,240.8 -1,185.3 -1,130.7 -1,077.0 -1,024.1 -972.2 -921.3 -921.1 -871.3 -835.1 -822.4 -774.6 -727.8 -682.1 -637.4 -628.9 -593.9 -562.1 -551.5 -510.1 -469.9 -430.7 -392.5 -370.2 -355.4 -321.7 -319.4 -284.4 -250.4 -217.5 -185.4 -154.4 -147.5 -124.2 -114.2 -100.9 -96.1 -73.0 -50.8 -33.8 -17.2 -11.7 -10.9 -10.5 -6.5 -5.8 -5.6 -2.5 -2.0 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 1,240.75 1,185.26 1,130.67 1,076.95 1,024.13 972.23 921.28 921.07 871.32 835.13 822.42 774.59 727.81 682.09 637.45 628.91 593.89 562.12 551.47 510.14 469.87 430.67 392.52 370.22 355.44 321.67 319.40 284.43 250.45 217.46 185.43 154.36 147.48 124.25 114.23 100.87 96.14 73.01 50.79 33.85 17.20 11.69 10.87 10.47 6.48 5.75 5.61 2.46 1.98 8,295.02 8,189.47 8,081.29 7,970.49 7,857.06 7,741.01 7,622.33 7,621.83 7,501.03 7,498.09 7,465.86 7,341.18 7,213.88 7,083.96 6,951.42 6,925.39 6,816.24 5,796.47 5,768.66 5,657.44 5,543.60 5,427.13 5,308.04 5,235.56 5,186.33 3,857.01 3,851.71 3,767.41 3,680.49 3,590.95 3,498.78 3,403.98 3,382.19 3,304.60 2,974.75 2,935.54 2,918.31 2,830.61 2,725.98 2,605.33 2,484.68 2,380.92 2,364.03 2,355.57 2,267.51 1,876.06 1,873.71 1,798.04 1,778.30 2,165.08 2,121.04 2,076.99 2,032.95 1,988.91 1,944.87 1,900.82 1,900.64 1,856.78 1,855.72 1,844.18 1,800.14 1,756.10 1,712.05 1,668.01 1,659.46 1,623.97 1,430.05 1,420.18 1,381.32 1,342.46 1,303.60 1,264.74 1,241.49 1,225.87 969.12 967.13 936.05 904.96 873.87 842.79 811.70 804.67 780.61 719.74 706.63 700.93 672.43 643.93 615.43 586.93 562.42 558.43 556.43 535.63 444.14 443.39 424.73 420.07 14,306.35 13,730.28 13,166.04 12,613.65 12,073.09 11,544.37 11,027.49 11,025.36 10,522.45 10,510.47 10,380.18 9,890.36 9,412.38 8,946.23 8,491.93 8,405.13 8,049.46 7,073.77 6,976.53 6,599.99 6,233.89 5,878.24 5,533.04 5,331.57 5,198.28 4,061.20 4,044.57 3,788.77 3,541.33 3,302.24 3,071.51 2,849.13 2,800.03 2,635.11 2,443.38 2,355.21 2,317.37 2,132.78 1,955.84 1,786.57 1,624.96 1,492.10 1,471.01 1,460.51 1,353.36 1,137.15 1,133.33 1,039.99 1,017.28 12,493.79 12,082.08 11,673.09 11,267.07 10,864.26 10,464.90 10,069.24 10,067.60 9,677.52 9,668.17 9,566.25 9,179.95 8,798.15 8,421.09 8,049.01 7,977.39 7,682.15 6,526.94 6,450.44 6,151.49 5,856.63 5,566.11 5,280.17 5,111.44 4,999.05 3,681.17 3,668.51 3,471.96 3,278.28 3,087.70 2,900.48 2,716.85 2,675.87 2,535.56 2,297.47 2,225.52 2,194.45 2,041.16 1,881.59 1,717.91 1,561.69 1,433.29 1,412.90 1,402.75 1,299.24 1,091.91 1,088.70 1,000.34 978.39 0 0.01 0.04 0.1 0.18 0.28 0.4 0.4 0.55 0.67 0.72 0.92 1.13 1.37 1.64 1.69 1.93 2.16 2.24 2.58 2.95 3.34 3.76 4.02 4.2 4.64 4.67 5.17 5.7 6.26 6.85 7.46 7.6 8.09 8.32 8.62 8.75 9.43 10.13 10.84 11.56 12.19 12.29 12.34 12.88 13 13.02 13.61 13.76 0 -0.02 -0.04 -0.06 -0.08 -0.11 -0.13 -0.13 -0.15 -0.17 -0.17 -0.2 -0.22 -0.24 -0.26 -0.27 -0.29 -0.3 -0.31 -0.34 -0.36 -0.39 -0.41 -0.43 -0.44 -0.46 -0.46 -0.49 -0.52 -0.55 -0.57 -0.6 -0.6 -0.62 -0.63 -0.64 -0.64 -0.66 -0.67 -0.68 -0.69 -0.7 -0.7 -0.7 -0.7 -0.7 -0.7 -0.7 -0.7 0.111 0.109 0.108 0.106 0.105 0.103 0.102 0.102 0.100 0.096 0.095 0.093 0.092 0.090 0.088 0.087 0.085 0.095 0.094 0.092 0.089 0.086 0.083 0.081 0.079 0.097 0.097 0.092 0.086 0.080 0.073 0.066 0.064 0.058 0.059 0.053 0.051 0.043 0.032 0.025 0.013 0.010 0.010 0.009 0.006 0.007 0.007 0.003 0.002 ©2007 - 2020 by ATC LLC. All rights reserved. Page 6 of 13 Model Id : 5070 Scenario Id: 189274 1/6/2022 13:26:53 ASSET: 208478, Cheshire CODE: ANSI/TIA-222-H CUSTOMER: T-MOBILE ENG NO: 13704270_C3_07 Load Case: 1.0D + 1.0W Gust Response Factor: Dead load Factor: Wind Load Factor: 60 mph Wind with No Ice 20 Iterations 1.10 1.00 1.00 CALCULATED FORCES Seg Elev (ft) Pu FY (-) (kips) Vu FX (-) (kips) 0.00 5.00 10.00 15.00 20.00 25.00 30.00 30.02 35.00 38.69 40.00 45.00 50.00 55.00 60.00 60.97 65.00 68.73 70.00 75.00 80.00 85.00 90.00 92.99 95.00 99.68 100.00 105.00 110.00 115.00 120.00 125.00 126.13 130.00 131.70 134.00 135.00 140.00 145.00 150.00 155.00 159.30 160.00 160.35 164.00 164.84 165.00 169.00 170.00 -63.72 -61.55 -59.42 -57.33 -55.29 -53.29 -51.33 -51.32 -47.57 -44.84 -44.34 -42.48 -40.66 -38.89 -37.16 -36.82 -34.31 -32.03 -31.66 -30.21 -28.79 -27.41 -26.08 -25.29 -24.38 -22.31 -22.24 -21.22 -20.24 -19.28 -18.35 -17.46 -17.26 -16.04 -15.51 -11.40 -11.25 -10.52 -7.76 -7.09 -3.28 -2.77 -2.70 -2.66 -1.57 -1.41 -1.39 -0.30 0.00 -9.35 -9.21 -9.07 -8.93 -8.78 -8.63 -8.55 -8.47 -8.33 -8.25 -8.14 -7.98 -7.81 -7.65 -7.55 -7.47 -7.33 -7.24 -7.14 -6.98 -6.81 -6.65 -6.52 -6.44 -6.34 -6.25 -6.17 -6.02 -5.87 -5.73 -5.58 -5.50 -5.43 -5.34 -5.29 -4.22 -4.14 -4.01 -3.08 -2.96 -1.10 -1.02 -1.01 -0.96 -0.76 -0.75 -0.71 -0.44 -0.44 Tu MY (ft-kips) 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 Mu MZ (ft-kips) Mu MX (ft-kips) Resultant Moment (ft-kips) Phi Pn (kips) Phi Vn (kips) Phi Tn (ft-kips) Phi Mn (ft-kips) Total Deflect (in) Rotation (deg) Ratio -1,073.4 -1,026.6 -980.6 -935.2 -890.6 -846.7 -803.5 -803.4 -761.2 -730.4 -719.6 -678.9 -639.0 -599.9 -561.7 -554.4 -524.3 -496.9 -487.7 -452.0 -417.2 -383.1 -349.8 -330.3 -317.4 -287.7 -285.7 -254.8 -224.7 -195.4 -166.7 -138.8 -132.6 -111.6 -102.5 -90.4 -86.1 -65.4 -45.4 -30.0 -14.5 -9.8 -9.1 -8.7 -5.2 -4.6 -4.4 -1.6 -1.2 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 1,073.38 1,026.61 980.57 935.23 890.59 846.68 803.53 803.35 761.16 730.42 719.62 678.90 639.00 599.93 561.69 554.36 524.28 496.93 487.74 452.04 417.16 383.09 349.82 330.31 317.36 287.69 285.70 254.84 224.73 195.37 166.73 138.81 132.60 111.60 102.51 90.35 86.14 65.43 45.39 29.97 14.52 9.78 9.07 8.72 5.21 4.57 4.45 1.62 1.18 8,295.02 8,189.47 8,081.29 7,970.49 7,857.06 7,741.01 7,622.33 7,621.83 7,501.03 7,498.09 7,465.86 7,341.18 7,213.88 7,083.96 6,951.42 6,925.39 6,816.24 5,796.47 5,768.66 5,657.44 5,543.60 5,427.13 5,308.04 5,235.56 5,186.33 3,857.01 3,851.71 3,767.41 3,680.49 3,590.95 3,498.78 3,403.98 3,382.19 3,304.60 2,974.75 2,935.54 2,918.31 2,830.61 2,725.98 2,605.33 2,484.68 2,380.92 2,364.03 2,355.57 2,267.51 1,876.06 1,873.71 1,798.04 1,778.30 2,165.08 2,121.04 2,076.99 2,032.95 1,988.91 1,944.87 1,900.82 1,900.64 1,856.78 1,855.72 1,844.18 1,800.14 1,756.10 1,712.05 1,668.01 1,659.46 1,623.97 1,430.05 1,420.18 1,381.32 1,342.46 1,303.60 1,264.74 1,241.49 1,225.87 969.12 967.13 936.05 904.96 873.87 842.79 811.70 804.67 780.61 719.74 706.63 700.93 672.43 643.93 615.43 586.93 562.42 558.43 556.43 535.63 444.14 443.39 424.73 420.07 14,306.35 13,730.28 13,166.04 12,613.65 12,073.09 11,544.37 11,027.49 11,025.36 10,522.45 10,510.47 10,380.18 9,890.36 9,412.38 8,946.23 8,491.93 8,405.13 8,049.46 7,073.77 6,976.53 6,599.99 6,233.89 5,878.24 5,533.04 5,331.57 5,198.28 4,061.20 4,044.57 3,788.77 3,541.33 3,302.24 3,071.51 2,849.13 2,800.03 2,635.11 2,443.38 2,355.21 2,317.37 2,132.78 1,955.84 1,786.57 1,624.96 1,492.10 1,471.01 1,460.51 1,353.36 1,137.15 1,133.33 1,039.99 1,017.28 12,493.79 12,082.08 11,673.09 11,267.07 10,864.26 10,464.90 10,069.24 10,067.60 9,677.52 9,668.17 9,566.25 9,179.95 8,798.15 8,421.09 8,049.01 7,977.39 7,682.15 6,526.94 6,450.44 6,151.49 5,856.63 5,566.11 5,280.17 5,111.44 4,999.05 3,681.17 3,668.51 3,471.96 3,278.28 3,087.70 2,900.48 2,716.85 2,675.87 2,535.56 2,297.47 2,225.52 2,194.45 2,041.16 1,881.59 1,717.91 1,561.69 1,433.29 1,412.90 1,402.75 1,299.24 1,091.91 1,088.70 1,000.34 978.39 0 0.01 0.04 0.09 0.15 0.24 0.35 0.35 0.48 0.58 0.63 0.79 0.98 1.2 1.43 1.47 1.68 1.88 1.95 2.25 2.57 2.91 3.28 3.51 3.67 4.06 4.08 4.52 4.99 5.48 6 6.54 6.66 7.1 7.3 7.57 7.68 8.29 8.9 9.53 10.17 10.72 10.81 10.86 11.33 11.44 11.46 11.98 12.11 0 -0.02 -0.04 -0.05 -0.07 -0.09 -0.11 -0.11 -0.13 -0.15 -0.15 -0.17 -0.19 -0.21 -0.23 -0.23 -0.25 -0.27 -0.27 -0.29 -0.32 -0.34 -0.36 -0.37 -0.38 -0.4 -0.41 -0.43 -0.46 -0.48 -0.5 -0.53 -0.53 -0.55 -0.55 -0.56 -0.57 -0.58 -0.59 -0.61 -0.61 -0.62 -0.62 -0.62 -0.62 -0.62 -0.62 -0.62 -0.62 0.094 0.093 0.091 0.090 0.089 0.088 0.087 0.087 0.085 0.082 0.081 0.080 0.078 0.077 0.075 0.075 0.073 0.082 0.081 0.079 0.076 0.074 0.071 0.069 0.068 0.084 0.084 0.079 0.074 0.069 0.063 0.056 0.055 0.049 0.050 0.045 0.043 0.036 0.027 0.020 0.011 0.008 0.008 0.007 0.005 0.005 0.005 0.002 0.001 ©2007 - 2020 by ATC LLC. All rights reserved. Page 7 of 13 Model Id : 5070 Scenario Id: 189274 1/6/2022 13:26:53 ASSET: 208478, Cheshire CODE: ANSI/TIA-222-H CUSTOMER: T-MOBILE ENG NO: 13704270_C3_07 EQUIVALENT LATERAL FORCES METHOD ANALYSIS (Based on ASCE7-16 Chapters 11, 12 and 15) Spectral Response Acceleration for Short Period (SS): 0.200 Spectral Response Acceleration at 1.0 Second Period (S1): 0.055 Long-Period Transition Period (TL – Seconds): 6 Importance Factor (Ie): 1.000 Site Coefficient Fa: 1.600 Site Coefficient Fv: 2.400 Response Modification Coefficient (R): 1.500 Design Spectral Response Acceleration at Short Period (Sds): 0.213 Design Spectral Response Acceleration at 1.0 Second Period (Sd1): 0.088 Seismic Response Coefficient (Cs): 0.034 Upper Limit CS: 0.034 Lower Limit CS: 0.030 Period based on Rayleigh Method (sec): 1.710 Redundancy Factor (p): 1.000 Seismic Force Distribution Exponent (k): 1.600 Total Unfactored Dead Load: 63.730 k Seismic Base Shear (E): 1.2D + 1.0Ev + 1.0Eh 2.190 k Seismic Segment 48 47 46 45 44 43 42 41 40 39 38 37 36 35 34 33 32 31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16 15 ©2007 - 2020 by ATC LLC. All rights reserved. Height Above Base (ft) Weight (lb) Wz (lb-ft) 169.5 167 164.92 164.42 162.1753 160.1753 159.65 157.15 152.5 147.5 142.5 137.5 134.5 132.8502 130.8502 128.065 125.565 122.5 117.5 112.5 107.5 102.5 99.8402 97.3402 93.9952 91.4952 87.5 82.5 77.5 72.5 69.3654 66.8654 62.9852 60.4852 84 345 14 161 717 39 78 488 635 663 702 730 149 361 526 1,222 198 895 925 955 985 1,015 66 2,075 909 782 1,338 1,375 1,413 1,451 374 2,277 2,510 331 317 1,272 51 580 2,522 133 266 1,632 2,023 2,001 2,007 1,970 389 921 1,311 2,942 462 2,006 1,939 1,867 1,791 1,710 106 3,217 1,333 1,098 1,748 1,635 1,519 1,402 337 1,932 1,935 239 Page 8 of 13 Cvx Horizontal Force (lb) Vertical Force (lb) 0.004 0.015 0.001 0.007 0.030 0.002 0.003 0.019 0.024 0.024 0.024 0.023 0.005 0.011 0.015 0.035 0.005 0.024 0.023 0.022 0.021 0.020 0.001 0.038 0.016 0.013 0.021 0.019 0.018 0.016 0.004 0.023 0.023 0.003 8 33 1 15 65 3 7 42 52 52 52 51 10 24 34 76 12 52 50 48 46 44 3 83 34 28 45 42 39 36 9 50 50 6 104 429 18 200 891 48 96 607 789 823 873 907 186 448 654 1,519 246 1,112 1,149 1,187 1,224 1,262 82 2,579 1,130 972 1,662 1,709 1,756 1,803 465 2,830 3,119 411 Model Id : 5070 Scenario Id: 189274 1/6/2022 13:26:53 ASSET: 208478, Cheshire CODE: ANSI/TIA-222-H CUSTOMER: T-MOBILE ENG NO: 13704270_C3_07 Segment 14 13 12 11 10 9 8 7 6 5 4 3 2 1 dbSpectra DS1F03F36D-N RFS SC3-W100AC Generic Flat Stand-Off Generic Flat Stand-Off Raycap DC6-48-60-18-8C-EV Ericsson RRUS A2 Ericsson RRUS 4415 B30 Ericsson 4478 Band 14 (15" Height) Ericsson RRUS 4449 B5, B12 Ericsson RRU22 Ericsson RRUS 12 Ericsson 8843 Raycap DC9-48-60-24-8C-EV CCI HPA-65R-BUU-H8 Generic Round Sector Frame CCI DMP65R-BU8D CCI TPA65R-BU8D Samsung RT4401-48A Samsung B2/B66A RRH-BR049 Samsung B5/B13 RRH-BR04C RFS DB-C1-12C-24AB-0Z JMA Wireless MX10FIT665-xx Generic Flat Light Sector Frame Ericsson Radio 4460 B25+B66 Ericsson Radio 4480 B71+B85A Ericsson Air6449 B41 RFS APXVAALL24 43-U-NA20 Generic Flat Platform with Handrails 0.9D - 1.0Ev + 1.0Eh Height Above Base (ft) Weight (lb) Wz (lb-ft) 57.5 52.5 47.5 42.5 39.345 36.845 32.5104 30.0104 27.5 22.5 17.5 12.5 7.5 2.5 170 170 169 164 159.3 155 155 155 155 155 155 155 155 155 155 155 155 145 145 145 145 145 145 134 134 134 134 134 1,731 1,774 1,817 1,859 494 2,725 3,750 8 1,957 2,000 2,042 2,085 2,128 2,170 142 80 750 375 16 90 138 180 213 317 150 255 16 408 900 287 248 56 253 211 32 320 1,200 327 252 312 368 2,500 Cvx Horizontal Force (lb) Vertical Force (lb) 1,153 1,021 891 762 179 889 1,000 2 399 296 202 120 54 9 539 303 2,818 1,343 55 294 451 588 697 1,038 491 834 52 1,334 2,943 939 809 164 744 620 94 941 3,526 847 652 808 954 6,472 0.014 0.012 0.010 0.009 0.002 0.010 0.012 0.000 0.005 0.004 0.002 0.001 0.001 0.000 0.006 0.004 0.033 0.016 0.001 0.004 0.005 0.007 0.008 0.012 0.006 0.010 0.001 0.016 0.035 0.011 0.010 0.002 0.009 0.007 0.001 0.011 0.042 0.010 0.008 0.010 0.011 0.076 30 26 23 20 5 23 26 0 10 8 5 3 1 0 14 8 73 35 1 8 12 15 18 27 13 21 1 34 76 24 21 4 19 16 2 24 91 22 17 21 25 167 2,151 2,204 2,257 2,310 614 3,386 4,660 10 2,432 2,485 2,538 2,591 2,644 2,697 176 99 932 466 20 112 171 223 265 394 186 317 20 507 1,118 357 308 69 315 262 40 398 1,491 406 313 388 458 3,107 63,726 84,937 1.000 2,187 79,190 Height Above Base (ft) Weight (lb) Wz (lb-ft) Cvx Horizontal Force (lb) Vertical Force (lb) 169.5 167 164.92 164.42 162.1753 160.1753 159.65 157.15 152.5 147.5 142.5 137.5 134.5 132.8502 130.8502 84 345 14 161 717 39 78 488 635 663 702 730 149 361 526 317 1,272 51 580 2,522 133 266 1,632 2,023 2,001 2,007 1,970 389 921 1,311 0.004 0.015 0.001 0.007 0.030 0.002 0.003 0.019 0.024 0.024 0.024 0.023 0.005 0.011 0.015 8 33 1 15 65 3 7 42 52 52 52 51 10 24 34 72 296 12 138 615 33 66 419 544 568 602 626 128 309 451 Seismic (Reduced DL) Segment 48 47 46 45 44 43 42 41 40 39 38 37 36 35 34 ©2007 - 2020 by ATC LLC. All rights reserved. Page 9 of 13 Model Id : 5070 Scenario Id: 189274 1/6/2022 13:26:53 ASSET: 208478, Cheshire CODE: ANSI/TIA-222-H CUSTOMER: T-MOBILE ENG NO: 13704270_C3_07 Segment 33 32 31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 dbSpectra DS1F03F36D-N RFS SC3-W100AC Generic Flat Stand-Off Generic Flat Stand-Off Raycap DC6-48-60-18-8C-EV Ericsson RRUS A2 Ericsson RRUS 4415 B30 Ericsson 4478 Band 14 (15" Height) Ericsson RRUS 4449 B5, B12 Ericsson RRU22 Ericsson RRUS 12 Ericsson 8843 Raycap DC9-48-60-24-8C-EV CCI HPA-65R-BUU-H8 Generic Round Sector Frame CCI DMP65R-BU8D CCI TPA65R-BU8D Samsung RT4401-48A Samsung B2/B66A RRH-BR049 Samsung B5/B13 RRH-BR04C RFS DB-C1-12C-24AB-0Z JMA Wireless MX10FIT665-xx Generic Flat Light Sector Frame Ericsson Radio 4460 B25+B66 Ericsson Radio 4480 B71+B85A Ericsson Air6449 B41 RFS APXVAALL24 43-U-NA20 Generic Flat Platform with Handrails 1.2D + 1.0Ev + 1.0Eh Height Above Base (ft) Weight (lb) Wz (lb-ft) 128.065 125.565 122.5 117.5 112.5 107.5 102.5 99.8402 97.3402 93.9952 91.4952 87.5 82.5 77.5 72.5 69.3654 66.8654 62.9852 60.4852 57.5 52.5 47.5 42.5 39.345 36.845 32.5104 30.0104 27.5 22.5 17.5 12.5 7.5 2.5 170 170 169 164 159.3 155 155 155 155 155 155 155 155 155 155 155 155 145 145 145 145 145 145 134 134 134 134 134 1,222 198 895 925 955 985 1,015 66 2,075 909 782 1,338 1,375 1,413 1,451 374 2,277 2,510 331 1,731 1,774 1,817 1,859 494 2,725 3,750 8 1,957 2,000 2,042 2,085 2,128 2,170 142 80 750 375 16 90 138 180 213 317 150 255 16 408 900 287 248 56 253 211 32 320 1,200 327 252 312 368 2,500 63,726 Cvx Horizontal Force (lb) Vertical Force (lb) 2,942 462 2,006 1,939 1,867 1,791 1,710 106 3,217 1,333 1,098 1,748 1,635 1,519 1,402 337 1,932 1,935 239 1,153 1,021 891 762 179 889 1,000 2 399 296 202 120 54 9 539 303 2,818 1,343 55 294 451 588 697 1,038 491 834 52 1,334 2,943 939 809 164 744 620 94 941 3,526 847 652 808 954 6,472 0.035 0.005 0.024 0.023 0.022 0.021 0.020 0.001 0.038 0.016 0.013 0.021 0.019 0.018 0.016 0.004 0.023 0.023 0.003 0.014 0.012 0.010 0.009 0.002 0.010 0.012 0.000 0.005 0.004 0.002 0.001 0.001 0.000 0.006 0.004 0.033 0.016 0.001 0.004 0.005 0.007 0.008 0.012 0.006 0.010 0.001 0.016 0.035 0.011 0.010 0.002 0.009 0.007 0.001 0.011 0.042 0.010 0.008 0.010 0.011 0.076 76 12 52 50 48 46 44 3 83 34 28 45 42 39 36 9 50 50 6 30 26 23 20 5 23 26 0 10 8 5 3 1 0 14 8 73 35 1 8 12 15 18 27 13 21 1 34 76 24 21 4 19 16 2 24 91 22 17 21 25 167 1,048 170 767 793 819 845 870 57 1,779 780 670 1,147 1,179 1,211 1,244 321 1,952 2,152 284 1,484 1,521 1,557 1,594 424 2,336 3,215 7 1,678 1,714 1,751 1,788 1,824 1,861 122 69 643 322 14 77 118 154 183 272 129 219 14 350 772 246 212 48 217 181 27 275 1,029 280 216 267 316 2,143 84,937 1.000 2,187 54,634 Seismic CALCULATED FORCES ©2007 - 2020 by ATC LLC. All rights reserved. Page 10 of 13 Model Id : 5070 Scenario Id: 189274 1/6/2022 13:26:53 ASSET: 208478, Cheshire CODE: ANSI/TIA-222-H CUSTOMER: T-MOBILE ENG NO: 13704270_C3_07 Seg Elev (ft) Pu FY (-) (kips) Vu FX (-) (kips) Tu MY (ft-kips) Mu MZ (fr-kips) Mu Mx (ft-kips) Resultant Moment (ft-kips) Phi Pn (kips) Phi Vn (kips) Phi Tn (kips) Phi Mn (kips) Total Deflect (in) Rotation (deg) Ratio 0.00 5.00 10.00 15.00 20.00 25.00 30.00 30.02 35.00 38.69 40.00 45.00 50.00 55.00 60.00 60.97 65.00 68.73 70.00 75.00 80.00 85.00 90.00 92.99 95.00 99.68 100.00 105.00 110.00 115.00 120.00 125.00 126.13 130.00 131.70 134.00 135.00 140.00 145.00 150.00 155.00 159.30 160.00 160.35 164.00 164.84 165.00 169.00 170.00 -76.49 -73.85 -71.26 -68.72 -66.23 -63.80 -63.79 -59.13 -55.75 -55.13 -52.82 -50.56 -48.36 -46.21 -45.80 -42.68 -39.85 -39.38 -37.58 -35.82 -34.11 -32.45 -31.48 -30.35 -27.77 -27.69 -26.43 -25.20 -24.02 -22.87 -21.75 -21.51 -19.99 -19.34 -18.89 -14.03 -13.12 -12.25 -8.85 -8.06 -3.48 -3.36 -3.32 -2.42 -1.76 -1.74 -1.31 -0.28 0.00 -2.19 -2.19 -2.20 -2.20 -2.19 -2.19 -2.19 -2.16 -2.14 -2.14 -2.12 -2.10 -2.08 -2.05 -2.05 -2.00 -1.95 -1.94 -1.90 -1.87 -1.82 -1.78 -1.75 -1.72 -1.63 -1.63 -1.59 -1.54 -1.49 -1.44 -1.39 -1.38 -1.30 -1.27 -1.24 -0.97 -0.92 -0.86 -0.65 -0.59 -0.27 -0.26 -0.26 -0.19 -0.14 -0.14 -0.11 -0.02 -0.02 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 -270.21 -259.27 -248.30 -237.32 -226.35 -215.38 -204.45 -204.40 -193.62 -185.71 -182.91 -172.29 -161.78 -151.38 -141.12 -139.14 -131.09 -123.83 -121.37 -111.86 -102.53 -93.41 -84.52 -79.28 -75.82 -68.19 -67.66 -59.74 -52.04 -44.57 -37.36 -30.41 -28.86 -23.82 -21.67 -18.82 -17.85 -13.26 -8.94 -5.70 -2.73 -1.56 -1.38 -1.29 -0.59 -0.47 -0.44 -0.02 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 270.21 259.27 248.30 237.32 226.35 215.38 204.45 204.40 193.62 185.71 182.91 172.29 161.78 151.38 141.12 139.14 131.09 123.83 121.37 111.86 102.53 93.41 84.52 79.28 75.82 68.19 67.66 59.74 52.04 44.57 37.36 30.41 28.86 23.82 21.67 18.82 17.85 13.26 8.94 5.70 2.73 1.56 1.38 1.29 0.59 0.47 0.44 0.02 0.00 8,295.02 8,189.47 8,081.29 7,970.49 7,857.06 7,741.01 7,622.33 7,621.83 7,501.03 7,498.09 7,465.86 7,341.18 7,213.88 7,083.96 6,951.42 6,925.39 6,816.24 5,796.47 5,768.66 5,657.44 5,543.60 5,427.13 5,308.04 5,235.56 5,186.33 3,857.01 3,851.71 3,767.41 3,680.49 3,590.95 3,498.78 3,403.98 3,382.19 3,304.60 2,974.75 2,935.54 2,918.31 2,830.61 2,725.98 2,605.33 2,484.68 2,380.92 2,364.03 2,355.57 2,267.51 1,876.06 1,873.71 1,798.04 1,778.30 2,165.08 2,121.04 2,076.99 2,032.95 1,988.91 1,944.87 1,900.82 1,900.64 1,856.78 1,855.72 1,844.18 1,800.14 1,756.10 1,712.05 1,668.01 1,659.46 1,623.97 1,430.05 1,420.18 1,381.32 1,342.46 1,303.60 1,264.74 1,241.49 1,225.87 969.12 967.13 936.05 904.96 873.87 842.79 811.70 804.67 780.61 719.74 706.63 700.93 672.43 643.93 615.43 586.93 562.42 558.43 556.43 535.63 444.14 443.39 424.73 420.07 14,306 13,730 13,166 12,614 12,073 11,544 11,027 11,025 10,522 10,510 10,380 9,890 9,412 8,946 8,492 8,405 8,049 7,074 6,977 6,600 6,234 5,878 5,533 5,332 5,198 4,061 4,045 3,789 3,541 3,302 3,072 2,849 2,800 2,635 2,443 2,355 2,317 2,133 1,956 1,787 1,625 1,492 1,471 1,461 1,353 1,137 1,133 1,040 1,017 12,493.79 12,082.08 11,673.09 11,267.07 10,864.26 10,464.90 10,069.24 10,067.60 9,677.52 9,668.17 9,566.25 9,179.95 8,798.15 8,421.09 8,049.01 7,977.39 7,682.15 6,526.94 6,450.44 6,151.49 5,856.63 5,566.11 5,280.17 5,111.44 4,999.05 3,681.17 3,668.51 3,471.96 3,278.28 3,087.70 2,900.48 2,716.85 2,675.87 2,535.56 2,297.47 2,225.52 2,194.45 2,041.16 1,881.59 1,717.91 1,561.69 1,433.29 1,412.90 1,402.75 1,299.24 1,091.91 1,088.70 1,000.34 978.39 0.00 0.00 0.01 0.02 0.04 0.06 0.09 0.09 0.12 0.15 0.16 0.20 0.25 0.30 0.36 0.37 0.43 0.48 0.50 0.57 0.65 0.74 0.83 0.89 0.93 1.02 1.03 1.14 1.26 1.38 1.51 1.64 1.67 1.78 1.82 1.89 1.92 2.06 2.21 2.36 2.52 2.65 2.67 2.68 2.79 2.82 2.83 2.95 2.98 0.00 0.00 -0.01 -0.01 -0.02 -0.02 -0.03 -0.03 -0.03 -0.04 -0.04 -0.04 -0.05 -0.05 -0.06 -0.06 -0.06 -0.07 -0.07 -0.07 -0.08 -0.09 -0.09 -0.09 -0.10 -0.10 -0.10 -0.11 -0.11 -0.12 -0.12 -0.13 -0.13 -0.13 -0.13 -0.14 -0.14 -0.14 -0.14 -0.15 -0.15 -0.15 -0.15 -0.15 -0.15 -0.15 -0.15 -0.15 -0.15 0.03 0.03 0.03 0.03 0.03 0.03 0.03 0.03 0.03 0.03 0.03 0.03 0.03 0.03 0.02 0.02 0.02 0.03 0.03 0.03 0.02 0.02 0.02 0.02 0.02 0.03 0.03 0.02 0.02 0.02 0.02 0.02 0.02 0.02 0.02 0.01 0.01 0.01 0.01 0.01 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.9D - 1.0Ev + 1.0Eh Seismic (Reduced DL) CALCULATED FORCES Seg Elev (ft) Pu FY (-) (kips) Vu FX (-) (kips) Tu MY (ft-kips) Mu MZ (fr-kips) Mu Mx (ft-kips) Resultant Moment (ft-kips) Phi Pn (kips) Phi Vn (kips) Phi Tn (kips) Phi Mn (kips) Total Deflect (in) Rotation (deg) Ratio 0.00 5.00 10.00 15.00 20.00 25.00 30.00 30.02 35.00 38.69 40.00 45.00 -52.77 -50.95 -49.16 -47.41 -45.70 -44.02 -44.01 -40.80 -38.46 -38.04 -36.44 -34.88 -2.19 -2.19 -2.19 -2.19 -2.19 -2.18 -2.18 -2.15 -2.13 -2.13 -2.11 -2.09 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 -268.37 -257.43 -246.48 -235.52 -224.57 -213.65 -202.76 -202.71 -191.98 -184.11 -181.32 -170.77 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 268.37 257.43 246.48 235.52 224.57 213.65 202.76 202.71 191.98 184.11 181.32 170.77 8,295.02 8,189.47 8,081.29 7,970.49 7,857.06 7,741.01 7,622.33 7,621.83 7,501.03 7,498.09 7,465.86 7,341.18 2,165.08 2,121.04 2,076.99 2,032.95 1,988.91 1,944.87 1,900.82 1,900.64 1,856.78 1,855.72 1,844.18 1,800.14 14,306 13,730 13,166 12,614 12,073 11,544 11,027 11,025 10,522 10,510 10,380 9,890 12,493.79 12,082.08 11,673.09 11,267.07 10,864.26 10,464.90 10,069.24 10,067.60 9,677.52 9,668.17 9,566.25 9,179.95 0.00 0.00 0.01 0.02 0.04 0.06 0.09 0.09 0.12 0.15 0.16 0.20 0.00 0.00 -0.01 -0.01 -0.02 -0.02 -0.03 -0.03 -0.03 -0.04 -0.04 -0.04 0.03 0.03 0.03 0.03 0.03 0.03 0.03 0.03 0.03 0.02 0.02 0.02 ©2007 - 2020 by ATC LLC. All rights reserved. Page 11 of 13 Model Id : 5070 Scenario Id: 189274 1/6/2022 13:26:53 ASSET: 208478, Cheshire CODE: ANSI/TIA-222-H CUSTOMER: T-MOBILE ENG NO: 13704270_C3_07 Seg Elev (ft) 50.00 55.00 60.00 60.97 65.00 68.73 70.00 75.00 80.00 85.00 90.00 92.99 95.00 99.68 100.00 105.00 110.00 115.00 120.00 125.00 126.13 130.00 131.70 134.00 135.00 140.00 145.00 150.00 155.00 159.30 160.00 160.35 164.00 164.84 165.00 169.00 170.00 Pu FY (-) (kips) -33.36 -31.88 -31.59 -29.44 -27.49 -27.17 -25.93 -24.71 -23.54 -22.39 -21.72 -20.94 -19.16 -19.10 -18.23 -17.39 -16.57 -15.78 -15.01 -14.84 -13.79 -13.34 -13.03 -9.68 -9.05 -8.45 -6.11 -5.56 -2.40 -2.32 -2.29 -1.67 -1.21 -1.20 -0.91 -0.19 0.00 Vu FX (-) (kips) -2.07 -2.04 -2.03 -1.98 -1.93 -1.92 -1.89 -1.85 -1.81 -1.76 -1.74 -1.70 -1.62 -1.62 -1.57 -1.52 -1.48 -1.43 -1.37 -1.36 -1.29 -1.25 -1.23 -0.96 -0.91 -0.85 -0.64 -0.59 -0.27 -0.26 -0.26 -0.19 -0.14 -0.14 -0.10 -0.02 -0.02 Tu MY (ft-kips) 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 Mu MZ (fr-kips) -160.32 -149.99 -139.80 -137.83 -129.84 -122.64 -120.19 -110.75 -101.50 -92.46 -83.64 -78.45 -75.03 -67.46 -66.95 -59.09 -51.47 -44.09 -36.95 -30.08 -28.54 -23.56 -21.43 -18.61 -17.65 -13.12 -8.84 -5.64 -2.70 -1.54 -1.36 -1.27 -0.58 -0.46 -0.44 -0.02 0.00 ©2007 - 2020 by ATC LLC. All rights reserved. Mu Mx (ft-kips) 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 Resultant Moment (ft-kips) 160.32 149.99 139.80 137.83 129.84 122.64 120.19 110.75 101.50 92.46 83.64 78.45 75.03 67.46 66.95 59.09 51.47 44.09 36.95 30.08 28.54 23.56 21.43 18.61 17.65 13.12 8.84 5.64 2.70 1.54 1.36 1.27 0.58 0.46 0.44 0.02 0.00 Phi Pn (kips) 7,213.88 7,083.96 6,951.42 6,925.39 6,816.24 5,796.47 5,768.66 5,657.44 5,543.60 5,427.13 5,308.04 5,235.56 5,186.33 3,857.01 3,851.71 3,767.41 3,680.49 3,590.95 3,498.78 3,403.98 3,382.19 3,304.60 2,974.75 2,935.54 2,918.31 2,830.61 2,725.98 2,605.33 2,484.68 2,380.92 2,364.03 2,355.57 2,267.51 1,876.06 1,873.71 1,798.04 1,778.30 Page 12 of 13 Phi Vn (kips) 1,756.10 1,712.05 1,668.01 1,659.46 1,623.97 1,430.05 1,420.18 1,381.32 1,342.46 1,303.60 1,264.74 1,241.49 1,225.87 969.12 967.13 936.05 904.96 873.87 842.79 811.70 804.67 780.61 719.74 706.63 700.93 672.43 643.93 615.43 586.93 562.42 558.43 556.43 535.63 444.14 443.39 424.73 420.07 Phi Tn (kips) 9,412 8,946 8,492 8,405 8,049 7,074 6,977 6,600 6,234 5,878 5,533 5,332 5,198 4,061 4,045 3,789 3,541 3,302 3,072 2,849 2,800 2,635 2,443 2,355 2,317 2,133 1,956 1,787 1,625 1,492 1,471 1,461 1,353 1,137 1,133 1,040 1,017 Model Id : 5070 Phi Mn (kips) 8,798.15 8,421.09 8,049.01 7,977.39 7,682.15 6,526.94 6,450.44 6,151.49 5,856.63 5,566.11 5,280.17 5,111.44 4,999.05 3,681.17 3,668.51 3,471.96 3,278.28 3,087.70 2,900.48 2,716.85 2,675.87 2,535.56 2,297.47 2,225.52 2,194.45 2,041.16 1,881.59 1,717.91 1,561.69 1,433.29 1,412.90 1,402.75 1,299.24 1,091.91 1,088.70 1,000.34 978.39 Total Deflect (in) 0.25 0.30 0.36 0.37 0.42 0.47 0.49 0.57 0.65 0.73 0.82 0.88 0.92 1.02 1.02 1.13 1.25 1.37 1.49 1.62 1.65 1.76 1.81 1.87 1.90 2.05 2.19 2.34 2.49 2.63 2.65 2.66 2.77 2.80 2.80 2.92 2.95 Scenario Id: 189274 Rotation (deg) -0.05 -0.05 -0.06 -0.06 -0.06 -0.07 -0.07 -0.07 -0.08 -0.08 -0.09 -0.09 -0.10 -0.10 -0.10 -0.11 -0.11 -0.12 -0.12 -0.13 -0.13 -0.13 -0.13 -0.14 -0.14 -0.14 -0.14 -0.14 -0.15 -0.15 -0.15 -0.15 -0.15 -0.15 -0.15 -0.15 -0.15 1/6/2022 13:26:53 Ratio 0.02 0.02 0.02 0.02 0.02 0.02 0.02 0.02 0.02 0.02 0.02 0.02 0.02 0.02 0.02 0.02 0.02 0.02 0.02 0.02 0.02 0.01 0.01 0.01 0.01 0.01 0.01 0.01 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 ASSET: 208478, Cheshire CODE: ANSI/TIA-222-H CUSTOMER: T-MOBILE ENG NO: 13704270_C3_07 ANALYSIS SUMMARY Reactions . . Max Usage . Load Case Shear FX (kips) Shear FZ (kips) Axial FY (kips) Moment MX (ft-kips) Moment MY (ft-kips) Moment MZ (ft-kips) Elev (ft) Interaction Ratio 1.2D + 1.0W 0.9D + 1.0W 1.2D + 1.0Di + 1.0Wi 1.2D + 1.0Ev + 1.0Eh 0.9D - 1.0Ev + 1.0Eh 1.0D + 1.0W 40.45 40.43 11.10 2.20 2.19 9.35 0.00 0.00 0.00 0.00 0.00 0.00 76.44 57.32 95.44 76.49 52.77 63.72 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 4657.08 4630.59 1240.75 270.21 268.37 1073.38 0.00 0.00 0.00 0.00 0.00 0.00 0.38 0.38 0.11 0.03 0.03 0.09 ©2007 - 2020 by ATC LLC. All rights reserved. Page 13 of 13 Model Id : 5070 Scenario Id: 189274 1/6/2022 13:26:53 208478 - Cheshire, CT (ANSI/TIA-222-H) 1:19 PM 1/6/2022 Base Plate & Anchor Rod Analysis Pole Dimensions Number of Sides Diameter Thickness Orientation Offset Base Reactions 18 73.69 17/32 in in ° Moment, Mu Axial, Pu Shear, Vu Neutral Axis Base Plate Shape Diameter, ø Thickness Grade Yield Strength, Fy Tensile Strength, Fu Clip Orientation Offset Anchor Rod Detail Clear Distance Applied Moment, Mu Bending Stress, φMn 50 65 N/A ksi ksi in ° d 4 1/8 619.8 3142.8 103.5 243.6 ksi ksi in ° k k Stiffeners Arrangement Quantity Height Width Effective Width Thickness Effective Thickness Notch Flat Edge Grade Yield Strength, Fy Tensile Strength, Fu Horizontal Weld Horizontal Fillet Size Bevel Depth Vertical Weld Vertical Fillet Size Weld Strength Electrode Coefficient Orientation Offset Vertical Weld, φRn Horz. Weld, φRn Ten. Capacity, φTn Comp. Capacity, φPn 0.000 #N/A #N/A in in in in in in in ksi ksi in in Fillet #N/A 0.0 #N/A 0.0 0.0 Report Capacities Component Capacity Base Plate 20% Anchor Rods 43% Dwyidag - Result Pass Pass - Quantity Bar Size Diameter, ø Bracket Type Circle Orientation Offset Applied Force, Pu Dywidag Bar, φPn in in in ° k k 0 83.99 0.0 0.0 η=0.5 in k k Radial 28 2 1/4 in 81.56 in A615-75 75 100 9.2 k-ft k k ° Dywidag Reinforcement Round 87.4 in 3 in A572-50 Original Anchor Rods Arrangement Quantity Diameter, ø Bolt Circle Grade Yield Strength, Fy Tensile Strength, Fu Spacing Orientation Offset Applied Force, Pu Anchor Rods, φPn 4,657.1 76.4 40.5 270 in ksi ° k k k k X:\C-E\Cheshire, CT (208478)\Structural Info\Monopole.Base-Plate-and-Anchor-Rod.v2.2 Additional Anchor Rods Quantity Diameter, ø Bolt Circle Grade Yield Strength, Fy Tensile Strength, Fu Bypass Base? Orientation Offset Applied Force, Pu Additional Rod, φPn in in #N/A #N/A ksi ksi ° k k 0.0 0.0 Additional Anchor Rods Quantity Diameter, ø Bolt Circle Grade Yield Strength, Fy Tensile Strength, Fu Bypass Base? Orientation Offset Applied Force, Pu Additional Rod, φPn in in #N/A #N/A 0.0 0.0 ksi ksi ° k k Individual Capacity Summary Component Capacity Base Plate 20% Pass Anchor Rods 43% Pass Dwyidag Bolt Group 1 Bolt Group 2 Stiffener Weld (V) Stiffener Weld (H) Stiffener Tension Stiffener Comp. - Checked By: 5/14/2020 Calculations for Monopole Base Plate & Anchor Rod Analysis Reaction Distribution Shear Vu k 40.5 40.5 0.0 0.0 0.0 0.0 Reaction Base Forces Anchor Rod Forces Additional Bolt (Grp1) Forces Additional Bolt (Grp2) Forces Dywidag Forces Stiffener Forces Base Plate Shape Diameter, D Thickness, t Yield Strength, Fy Tensile Strength, Fu Base Plate Chord Detail Type Detail Factor Clear Distance Factor 1.00 1.00 0.00 0.00 0.00 0.00 Geometric Properties Gross Section Area Pole Bolt Bolt1 Bolt2 Dywidag Stiffener 2 in 121.4809 3.9761 0.0000 0.0000 0.0000 0.0000 Anchor Rods Round 87.4 3 50 65 46.995 d 0.50 4.125 External Base Plate 40.217 5.840 103.629 619.8 4663.3 0.133 Chord Length AA Additional AA Section Modulus, Z Applied Moment, Mu Bending Capacity, φMn Capacity, Mu/φMn in in ksi ksi in - in3 k-ft k-ft OK 38.053 5.840 98.759 445.8 4444.2 0.100 in in Bend Line Length Additional Bend Line Section Modulus, Z Applied Moment, Mu Bending Capacity, φMn Capacity, Mu/φMn 31.040 0.000 69.839 619.8 3142.8 0.197 in in Internal Base Plate 0.000 Arc Length 0.000 Section Modulus, Z 0.000 Moment Arm 0.0 Applied Moment, Mu 0.0 Bending Capacity, φMn Anchor Rod Quantity, N Rod Diameter, d Bolt Circle, BC Yield Strength, Fy Tensile Strength, Fu Applied Axial, Pu Applied Shear, Vu Compressive Capacity, φPn Tensile Capacity, φRnt Interaction Capacity in3 k-ft k-ft OK in3 k-ft k-ft OK in in in ksi ksi k k k OK OK Bolt Quantity, N Bolt Diameter, d Bolt Circle, BC Yield Strength, Fy Tensile Strength, Fu Applied Axial, Pu Applied Shear, Vu Compressive Capacity, φPn Compressive Capacity, φPn Interaction Capacity 0 0 0 0 0 0.0 0.0 0.0 in in ksi ksi k k k 0 0 0 0 0 0.0 0.0 0.0 in in ksi ksi k k k Additional Bolt Group 2 Bolt Quantity, N Bolt Diameter, d Bolt Circle, BC Yield Strength, Fy Tensile Strength, Fu Applied Axial, Pu Applied Shear, Vu Compressive Capacity, φPn Compressive Capacity, φPn Interaction Capacity Dywidag Reinforcement Dywidag Quantity, N Dywidag Diameter, d Bolt Circle, BC Yield Strength, Fy Tensile Strength, Fu Applied Axial, Pu Compressive Capacity, φPn Capacity, Pu/φPn 2 in 6.7489 3.2477 0.0000 0.0000 0.0000 0.0000 Individual Inertia 4 in 0.6372 0.8393 0.0000 0.0000 0.0000 0.0000 Threads per Inch Moment of Inertia # in 81285.26 71297.05 0.00 0.00 0.00 0.00 4 4.5 0 0 Applied Axial Force, Pu Applied Horizontal Force, Vu 0.0 0.00 k k Vertical Weld Vert.-to-Stiffener a=ex/l Spacing Ratio, k Weld Coefficient, C Compressive Capacity, φPn Vert.-to-Plate a=ex/l Spacing Ratio, k Weld Coefficient, C Shear Capacity, φVn Pu/fPPn + Vu/fVVn #DIV/0! #DIV/0! #DIV/0! #N/A #DIV/0! #DIV/0! #DIV/0! #N/A - k k Horizontal Weld Horz.-to-Stiffener a=ex/l #DIV/0! Spacing Ratio, k #DIV/0! Weld Coefficient, C #DIV/0! 0.000 Effective Fillet #N/A Compressive Capacity, φPn Horz.-to-Pole a=ex/l #DIV/0! Spacing Ratio, k #DIV/0! Weld Coefficient, C #DIV/0! #N/A Shear Capacity, φVn Pu/fPPn + Vu/fVVn in k k Plate Tension Gross Cross Section Net Cross Section Tensile Capacity, φTn Capacity, Tu/φTn 0.000 0.000 0.0 - in2 in2 k #DIV/0! #DIV/0! 0.00 0.0 0.0 0.0 - in3 ksi k Plate Compression 3 in in k-ft k-ft Net Area Base Plate Stiffeners 28 2.25 81.56 75 100 103.5 0.5 243.6 0.425 0.429 Additional Bolt Group 1 in in Chord Length AB Additional AB Section Modulus, Z Applied Moment, Mu Bending Capacity, φMn Capacity, Mu/φMn Capacity, Mu/φMn Moment Mu k-ft 4657.1 4657.1 0.0 0.0 0.0 0.0 0 0 83.99 75 100 0.0 0.0 in in ksi ksi k k Radius of Gyration kl/r 4.71 (E/Fy) Buckling Stress(Fe) Crit. Buckling Stress(Fcr) Compressive Capacity, φPn Capacity, Pu/φPn Cheshire, CT Site Name: 208478 Site Number: MP Tower Type: Design Loads (Factored) - Analysis per TIA-222-H Standards Monolithic Mat & Pier Foundation Analysis Foundation Analysis Parameters Design / Analysis / Mapping: Compression/Leg: Uplift/Leg: Total Shear: Moment: Tower + Appurtenance Weight: Depth to Base of Foundation (l + t - h): Diameter of Pier (d): Length of Pier (l): Height of Pier above Ground (h): Width of Pad (W): Length of Pad (L): Thickness of Pad (t): Tower Leg Center to Center: Number of Tower Legs: Tower Center from Mat Center: Depth Below Ground Surface to Water Table: Unit Weight of Concrete: Unit Weight of Soil Above Water Table: Unit Weight of Water: Unit Weight of Soil Below Water Table: Friction Angle of Uplift: Coefficient of Shear Friction: Ultimate Compressive Bearing Pressure: Ultimate Passive Pressure on Pad Face: fSoil and Concrete Weight: fSoil: Analysis 76.4 0.0 40.5 4,657.1 76.4 6 9 4 0.5 33 33 2.5 0 1 0 11 150 125 62.4 62.6 15 0.5 10,000 0 0.9 0.75 Overturning Moment Usage Design OTM: OTM Resistance: Design OTM / OTM Resistance: 4920.0 k-ft 14644.7 k-ft 34% Pass Soil Bearing Pressure Usage Net Bearing Pressure: Factored Nominal Bearing Pressure: Factored Nominal (Net) Bearing Pressure: Load Direction Controling Design Bearing Pressure: Sliding Factor of Safety Ultimate Friction Resistance: Ultimate Passive Pressure Resistance: Total Factored Sliding Resistance: Sliding Design / Sliding Resistance: 1870 7500 25% k k k k-ft k ft ft ft ft ft ft ft ft ft ft pcf pcf pcf pcf ° psf psf - Foundation Steel Parameters Shear/Leg (Compression): 27.0 Shear/Leg (Uplift): 22.2 3,000 Concrete Strength (f'c): Pad Tension Steel Depth: 26.44 Dead Load Factor: 0.9 fShear: 0.75 fFlexure / Tension: 0.9 fCompression: 0.65 b: 0.85 Bottom Pad Rebar Size #: 9 # of Bottom Pad Rebar: 56 Pad Bottom Steel Area: 56.00 Pad Steel Fy: 60,000 Top Pad Rebar Size #: 9 # of Top Pad Rebar: 56 Pad Top Steel Area: 56.00 Pier Rebar Size #: 10 Pier Steel Area (Single Bar): 1.27 # of Pier Rebar: 48 Pier Steel Fy: 60,000 Pier Cage Diameter: 99.5 Rebar Strain Limit: 0.008 Steel Elastic Modulus: 29,000 Tie Rebar Size #: 5 Tie Steel Area (Single Bar): 0.31 Tie Spacing: 6 Tie Steel Fy: 60,000 Clear Cover: 3 k k psi in 2 in psi 2 in in2 psi in ksi in2 in psi in Design Guide Minimum Required Mat Width: Minimum Required Mat Thickness: Minimum Required # of Vertical in Pier: Minimum Required # of Mat Rebar: Maximum Allowable Tie Spacing: Minimum Allowable Tie Spacing: Minimum Pier Edge to Mat Edge: Minimum Required Mat Length: Minimum Required Foundation Depth: ft - OK ft - NG, Inc OK OK in - OK in - OK in - OK ft - OK ft - NG, Inc psf psf Pass Diagonal to Pad Edge 479.4 0.0 359.6 11% k k k Pass 14.17 2.58 37 21 20 3 31 14.17 7.18 Pad Strength Capacity Factored One Way Shear (Vu): One Way Shear Capacity (fVc): Vu / fVc: Load Direction Controling Shear Capacity: Lower Steel Pad Factored Moment (Mu): Lower Steel Pad Moment Capacity (fMn): Mu / fMn: Load Direction Controling Flexural Capacity: Upper Steel Pad Factored Moment (Mu): Upper Steel Pad Moment Capacity (fMn): Mu / fMn: Lower Pad Flexural Reinforcement Ratio: Upper Pad Flexural Reinforcement Ratio: Pad Shrinkage Reinforcement Ratio: Lower Pad Reinforcement Spacing: Upper Pad Reinforcement Spacing: Ultimate Punching Shear Stress, vu: Nominal Punching Shear Capacity (fcvc): vu / fcvc: Pier Moment Pad Flexure Transfer Ratio, γf: Moment Transfer Effective Flexural Width, Beff: Moment Transfer Through Pad Flexure: Moment Transfer Flexural Capacity (fMsc,f): gfMsc / fMsc,f: 1357.4 6305.9 22% 0.0053 0.0053 0.0107 7.1 7.1 49.45 164.3 30% 0.60 16.50 34695.94 39061.03 0% Pier Strength Capacity Factored Moment in Pier (Mu): Pier Moment Capacity (fMn): Mu / fMn: Factored Shear in Pier (Vu): Pier Shear Capacity (fVn): Vu / fVc: Pier Shear Reinforcement Ratio: Factored Tension in Pier (Tu): Pier Tension Capacity (fTn): Tu / fTn: Factored Compression in Pier (Pu): Pier Compression Capacity (fPn): Pu / fPn: Pier Compression Reinforcement Ratio: Minimum Depth to Develop Vertical Rebar: Minimum Hook Development Length: Minimum Mat Thickness / Edge Distance from Pier: Minimum Foundation Depth: Mu/fBMn + Tu/fTTn: 4818.9 13347.0 36% 40.5 1157.5 3% 0.0004 0.0 3291.8 0% 76.4 12106.1 1% 0.007 52 28 31.0 7.18 36% 343.9 860.1 40% k k ACI 318-14 25.5.5.1 Pass Parallel to Pad Edge 2666.6 6305.9 42% k-ft k-ft Pass ACI 318-14 22.3.1.1 Parallel to Pad Edge k-ft k-ft Pass OK - ACI 318-14 7.6.1.1 & 8.6.1.1 OK - ACI 318-14 7.6.1.1 & 8.6.1.1 OK - ACI 318-14 24.4.3.2 in in psi psi Pass OK - ACI 318-14 7.7.2.3, 8.7.2.2, & 24.4.3.3 OK - ACI 318-14 7.7.2.3, 8.7.2.2, & 24.4.3.3 ACI 318-14 R8.4.4.2.3 ACI 318-14 22.6.5.2 TIA-222-H 9.4.2 ft k-in k-in Pass k-ft k-ft Pass k k Pass TIA-222-H 9.4.2 TIA-222-H 9.4.2 ACI 318-14 22.5.1.1 OK - No Ties Necessary for Shear - ACI11.5.6.1 k k Pass k k ACI 318-14 22.4.2.1 Pass OK - TIA-222-H 9.4.1 in in in ft ACI 318-14 25.4.2.3 ACI 318-14 25.4.3.1 Pass S t r u c t u r a l A n a l y s i s A n t e nn a M o u n t A n a l y s is P r o p os e d T - M o b il e U p g r a d e T - M o b i l e S i t e 1 3 2 5 C e n t e k # : D a t e : M a x 1 : C T N H 5 6 8 A C h e s h i r e S t r e e t C h e s h i r e , C T P r o j e c t R e v R e p o r t N o . 2 1 0 8 5 . 0 3 J u l y J a n u a r y S t r e s s 2 1 , 2 0 2 1 3 , 2 0 2 2 R a t i o = 6 7 % Prep ared for: T-Mobile USA 35 Griffin Road Bloomf ield, CT 06002 CENTEK Engineering, Inc. Structural Analysis – Mount Analysis T-Mobile Antenna Upgrade – CTNH568A Cheshire, CT Rev 1 ~ January 3, 2022 Table of Contents SECTION 1 – REPORT § ANTE NNA AND AP PURTE NANCE SUMM ARY § STRUCTURE LO ADI NG § CONCL USION SECTION 2 – CALCULATIONS § W IND LO AD ON APPURTENA NCES § RISA3 D OUTP UT REP ORT SECTION 3 – REFERENCE MATERIALS (NOT INCLUDED WITHIN REPORT) § RF DATA SHEET, DATED 07/08/2021 TABLE OF CONTENTS TOC-1 January 3, 2022 Mr. Dan Reid Transcend Wireless 10 Industrial Ave Mahwah, NJ 07430 Re: Structural Letter ~ Antenna Mount T-Mobile – Site Ref: CTNH568A 1325 Cheshire Street Cheshire, CT 06410 Centek Project No. 21085.03 Dear Mr. Reid, Centek Engineering, Inc. has reviewed the T-Mobile antenna installation at the above-referenced site. The purpose of the review is to determine the structural adequacy of the proposed 12’-6” low profile platform with handrail (SitePro P/N: RMQP-496-HK). The review considered the effects of wind load, dead load, and ice load in accordance with the 2015 International Building Code as modified by the 2018 Connecticut State Building Code (CTBC), including ASCE 7-10 and ANSI/TIA-222-G Structural Standards for Steel Antenna Towers and Supporting Structures. The loads considered in this analysis consist of the following: § T-Mobile: Low Profile Platform:Three (3) RFS APXVAALL24_43-U-NA20 panel antennas, three (3) Ericsson AIR6449 b41 panel antennas, three (3) Ericsson 4480 B71+B85 remote radio heads and three (3) Ericsson 4460 B25+B66 remote radio heads on the proposed mount with a RAD center elevation of 134-ft +/- AGL. The antenna mount was analyzed per the requirements of the 2015 International Building Code as modified by the 2018 Connecticut State Building Code considering a nominal design wind speed of 97 mph for Cheshire as required in Appendix N of the 2018 Connecticut State Building Code. Based on our review of the installation, it is our opinion that the subject antenna mount has sufficient capacity to support the aforementioned antenna configuration. If there are any questions regarding this matter, please feel free to call. Respectfully Submitted by: Prepared by: Timothy J. Lynn, PE Structural Engineer Fernando J. Palacios Engineer CENTEK Engineering, Inc. Structural Analysis – Mount Analysis T-Mobile Antenna Upgrade – CTNH568A Cheshire, CT Rev 1 ~ January 3, 2022 Section 2 - Calculations Subject: Loads on Equipment Location: Cheshire,CT Rev. 1: 01/03/2022 Prepared by: F.J.P.. Checked by: T.J.L. Job No. 21085.03 Development of Design Heights, Exposure Coefficients, and Velocity Pressures Per TIA-222-G Wind Speeds Basic Wind Speed V ≔ 97 mph (User Input - 2018 CSBC Appendix N) Basic Wind Speed with Ice Vi ≔ 50 mph (User Input per Annex B of TIA-222-G) Input Structure_Type ≔ Pole (User Input) Structure Category = SC ≔ II (User Input) Exposure Category = Exp ≔ C Structure Type = Structure Height = Height to Center of Antennas = Radial Ice Thickness = Radial Ice Density = Topographic Factor = Gust Response Factor = (User Input) h ≔ 170.0 ft (User Input) z ≔ 134 ft (User Input) ti ≔ .75 in (User Input per Annex B of TIA-222-G) Id ≔ 56.00 pcf (User Input) Kzt ≔ 1.0 (User Input) Ka ≔ 1.0 (User Input) GH = 1.1 (User Input) Output Wind Direction Probability Factor = Importance Factors = ⎛ z ⎞ 0.1 Kiz ≔ ⎜―― ⎟ = 1.15 ⎝ 33 ⎠ Velocity Pressure Coefficient Antennas = ‖ Kd ≔ ‖ if Structure_Type = Pole ‖ ‖ 0.95 ‖ ‖ ‖ if Structure_Type = Lattice ‖ ‖ ‖ ‖ 0.85 ‖ = 0.95 (Per Table 2-3 of TIA-222-G) ‖ IWind ≔ ‖ if SC = 1 = 1 ‖ ‖ 0.87 ‖ ‖ ‖ if SC = 2 ‖ ‖ ‖ ‖ 1.00 ‖ if SC = 3 ‖ ‖ ‖ ‖ 1.15 ‖ ‖ IWind_w_Ice ≔ ‖ if SC = 1 = 1 ‖ ‖0 ‖ ‖ ‖ if SC = 2 ‖ ‖ ‖ ‖ 1.00 ‖ if SC = 3 ‖ ‖ ‖ ‖ 1.00 ‖ ‖ Iice ≔ ‖ if SC = 1 ‖ ‖0 ‖ ‖ ‖ if SC = 2 ‖ ‖ ‖ ‖ 1.00 ‖ if SC = 3 ‖ ‖ ‖ ‖ 1.25 ‖ =1 tiz ≔ 2.0 ⋅ ti ⋅ Iice ⋅ Kiz2 ⋅ Kzt 0.35 = 1.726 ⎛ ⎛ z ⎞⎞ Kz ≔ 2.01 ⋅ ⎜⎜―⎟⎟ ⎝⎝ zg ⎠⎠ ― α = 1.346 Velocity Pressure w/o Ice Antennas = qz ≔ 0.00256 ⋅ Kd ⋅ Kz ⋅ V 2 ⋅ IWind = 31 Velocity Pressure with Ice Antennas = qzice ≔ 0.00256 ⋅ Kd ⋅ Kz ⋅ Vi 2 ⋅ IWind = 8 CTNH568A_TIA RevG Load Calculations Rev.1.mcdx (Per Table 2-2 of TIA-222-G) Page 1 psf psf Subject: Loads on Equipment Location: Cheshire,CT Rev. 1: 01/03/2022 Prepared by: F.J.P.. Checked by: T.J.L. Job No. 21085.03 Development of Wind & Ice Load on Antennas Antenna Data: Antenna Model = RFS APXVAALL24_43-U-NA20 Antenna Shape = Flat Antenna Height = Lant ≔ 95.9 in (User Input) Antenna Width = Want ≔ 24.0 in (User Input) Tant ≔ 8.5 in (User Input) WTant ≔ 150 lbs (User Input) Antenna Thickness = Antenna Weight = Number of Antennas = Antenna Aspect Ratio = Antenna Force Coefficient = (User Input) Nant ≔ 1 (User Input) L ant Arant ≔ ――= 4.0 Want Caant = 1.27 Wind Load (without ice) Surface Area for One Antenna = Total Antenna Wind Force Front = Surface Area for One Antenna = Total Antenna Wind Force Side = Lant ⋅ Want SAantF ≔ ―――― = 16 144 sf Fant ≔ qz ⋅ GH ⋅ Caant ⋅ Ka ⋅ SAantF = 686 lbs Lant ⋅ Tant SAantS ≔ ―――― = 5.7 144 sf Fant ≔ qz ⋅ GH ⋅ Caant ⋅ Ka ⋅ SAantS = 243 lbs ⎛⎝Lant + 2 ⋅ tiz⎞⎠ ⋅ ⎛⎝Want + 2 ⋅ tiz⎞⎠ SAICEantF ≔ ―――――――――― = 18.9 144 sf Fiant ≔ qzice ⋅ GH ⋅ Caant ⋅ K a ⋅ SAICEantF = 216 lbs ⎛⎝Lant + 2 ⋅ tiz⎞⎠ ⋅ ⎛⎝Tant + 2 ⋅ tiz⎞⎠ SAICEantS ≔ ――――――――― = 8.2 144 sf Fiant ≔ qzice ⋅ GH ⋅ Caant ⋅ K a ⋅ SAICEantS = 94 lbs Wind Load (with ice) Surface Area for One Antenna w/ Ice = Total Antenna Wind Force w/ Ice Front = Surface Area for One Antenna w/ Ice = Total Antenna Wind Force w/ Ice Side = Gravity Load (without ice) Weight of All Antennas = WTant ⋅ Nant = 150 lbs Gravity Loads (ice only) Volume of Each Antenna = Vant ≔ Lant ⋅ Want ⋅ Tant = 2 ⋅ 10 4 cu in Volume of Ice on Each Antenna = Vice ≔ ⎛⎝L ant + 2 ⋅ tiz⎞⎠ ⋅ ⎛⎝Want + 2 ⋅ tiz⎞⎠ ⋅ ⎛⎝Tant + 2 ⋅ tiz⎞⎠ - Vant = 1 ⋅ 10 4 Weight of Ice on Each Antenna = Vice WICEant ≔ ――⋅ Id = 422 1728 lbs WICEant ⋅ Nant = 422 lbs cu in Weight of Ice on All Antennas = CTNH568A_TIA RevG Load Calculations Rev.1.mcdx Page 2 Subject: Loads on Equipment Location: Cheshire,CT Rev. 1: 01/03/2022 Prepared by: F.J.P.. Checked by: T.J.L. Job No. 21085.03 Development of Wind & Ice Load on Antennas Antenna Data: Antenna Model = Ericsson - AIR6449 B41 Antenna Shape = Flat Antenna Height = Lant ≔ 33.1 in (User Input) Antenna Width = Want ≔ 20.5 in (User Input) Tant ≔ 8.3 in (User Input) WTant ≔ 103 lbs (User Input) Antenna Thickness = Antenna Weight = Number of Antennas = Antenna Aspect Ratio = Antenna Force Coefficient = (User Input) Nant ≔ 1 (User Input) L ant Arant ≔ ――= 1.6 Want Caant = 1.2 Wind Load (without ice) Surface Area for One Antenna = Total Antenna Wind Force Front = Surface Area for One Antenna = Total Antenna Wind Force Side = Lant ⋅ Want SAantF ≔ ―――― = 4.7 144 sf Fant ≔ qz ⋅ GH ⋅ Caant ⋅ Ka ⋅ SAantF = 192 lbs Lant ⋅ Tant SAantS ≔ ―――― = 1.9 144 sf Fant ≔ qz ⋅ GH ⋅ Caant ⋅ Ka ⋅ SAantS = 78 lbs ⎛⎝Lant + 2 ⋅ tiz⎞⎠ ⋅ ⎛⎝Want + 2 ⋅ tiz⎞⎠ SAICEantF ≔ ―――――――――― = 6.1 144 sf Fiant ≔ qzice ⋅ GH ⋅ Caant ⋅ K a ⋅ SAICEantF = 66 lbs ⎛⎝Lant + 2 ⋅ tiz⎞⎠ ⋅ ⎛⎝Tant + 2 ⋅ tiz⎞⎠ SAICEantS ≔ ――――――――― = 3 144 sf Fiant ≔ qzice ⋅ GH ⋅ Caant ⋅ K a ⋅ SAICEantS = 32 lbs Wind Load (with ice) Surface Area for One Antenna w/ Ice = Total Antenna Wind Force w/ Ice Front = Surface Area for One Antenna w/ Ice = Total Antenna Wind Force w/ Ice Side = Gravity Load (without ice) Weight of All Antennas = WTant ⋅ Nant = 103 lbs Gravity Loads (ice only) Volume of Each Antenna = Vant ≔ Lant ⋅ Want ⋅ Tant = 5632 cu in Volume of Ice on Each Antenna = Vice ≔ ⎛⎝L ant + 2 ⋅ tiz⎞⎠ ⋅ ⎛⎝Want + 2 ⋅ tiz⎞⎠ ⋅ ⎛⎝Tant + 2 ⋅ tiz⎞⎠ - Vant = 4656 Weight of Ice on Each Antenna = Vice WICEant ≔ ――⋅ Id = 151 1728 lbs WICEant ⋅ Nant = 151 lbs cu in Weight of Ice on All Antennas = CTNH568A_TIA RevG Load Calculations Rev.1.mcdx Page 3 Subject: Loads on Equipment Location: Cheshire,CT Rev. 1: 01/03/2022 Prepared by: F.J.P.. Checked by: T.J.L. Job No. 21085.03 Development of Wind & Ice Load on RRUS's RRUS Data: RRUS Model = Ericsson 4480 B71+B85 RRUS Shape = Flat RRUS Height = LRRUS ≔ 21.8 in (User Input) RRUS Width = WRRUS ≔ 15.7 in (User Input) TRRUS ≔ 7.5 in (User Input) WTRRUS ≔ 84 lbs (User Input) RRUS Thickness = RRUS Weight = (User Input) Number of RRUS's = NRRUS ≔ 1 RRUS Aspect Ratio = LRRUS ArRRUS ≔ ――― = 1.4 WRRUS RRUS Force Coefficient = CaRRUS = 1.2 Wind Load (without ice) Surface Area for One RRUS = Total RRUS Wind Force = Surface Area for One RRUS = Total RRUS Wind Force = LRRUS ⋅ WRRUS SARRUSF ≔ ―――――= 2.4 144 sf FRRUS ≔ qz ⋅ GH ⋅ CaRRUS ⋅ Ka ⋅ SARRUSF = 97 lbs LRRUS ⋅ TRRUS SARRUSS ≔ ――――― = 1.1 144 sf FRRUS ≔ qz ⋅ GH ⋅ CaRRUS ⋅ Ka ⋅ SARRUSS = 46 lbs ⎛⎝LRRUS + 2 ⋅ tiz⎞⎠ ⋅ ⎛⎝WRRUS + 2 ⋅ tiz⎞⎠ SAICERRUSF ≔ ――――――――――― = 3.4 144 sf FiRRUS ≔ qzice ⋅ GH ⋅ CaRRUS ⋅ Ka ⋅ SAICERRUSF = 36 lbs ⎛⎝L RRUS + 2 ⋅ tiz⎞⎠ ⋅ ⎛⎝TRRUS + 2 ⋅ tiz⎞⎠ SAICERRUSS ≔ ――――――――――― = 1.9 144 sf FiRRUS ≔ qzice ⋅ GH ⋅ CaRRUS ⋅ Ka ⋅ SAICERRUSS = 21 lbs WTRRUS ⋅ NRRUS = 84 lbs VRRUS ≔ LRRUS ⋅ WRRUS ⋅ TRRUS = 2567 cu in Wind Load (with ice) Surface Area for One RRUS w/ Ice = Total RRUS Wind Force w/ Ice = Surface Area for One RRUS w/ Ice = Total RRUS Wind Force w/ Ice = Gravity Load (without ice) Weight of All RRUSs = Gravity Loads (ice only) Volume of Each RRUS = Volume of Ice on Each RRUS = Vice ≔ ⎛⎝L RRUS + 2 ⋅ tiz⎞⎠ ⋅ ⎛⎝WRRUS + 2 ⋅ tiz⎞⎠ ⋅ ⎛⎝TRRUS + 2 ⋅ tiz⎞⎠ - VRRUS = 2729 Weight of Ice on Each RRUS = Vice WICERRUS ≔ ――⋅ Id = 88 1728 lbs WICERRUS ⋅ NRRUS = 88 lbs cu in Weight of Ice on All RRUSs = CTNH568A_TIA RevG Load Calculations Rev.1.mcdx Page 4 Subject: Loads on Equipment Location: Cheshire,CT Rev. 1: 01/03/2022 Prepared by: F.J.P.. Checked by: T.J.L. Job No. 21085.03 Development of Wind & Ice Load on RRUS's RRUS Data: RRUS Model = Ericsson 4460 B25+B66 RRUS Shape = Flat RRUS Height = LRRUS ≔ 19.6 in (User Input) RRUS Width = WRRUS ≔ 15.7 in (User Input) TRRUS ≔ 12.1 in (User Input) WTRRUS ≔ 109 lbs (User Input) RRUS Thickness = RRUS Weight = (User Input) Number of RRUS's = NRRUS ≔ 1 RRUS Aspect Ratio = LRRUS ArRRUS ≔ ――― = 1.2 WRRUS RRUS Force Coefficient = CaRRUS = 1.2 Wind Load (without ice) Surface Area for One RRUS = Total RRUS Wind Force = Surface Area for One RRUS = Total RRUS Wind Force = LRRUS ⋅ WRRUS SARRUSF ≔ ―――――= 2.1 144 sf FRRUS ≔ qz ⋅ GH ⋅ CaRRUS ⋅ Ka ⋅ SARRUSF = 87 lbs LRRUS ⋅ TRRUS SARRUSS ≔ ――――― = 1.6 144 sf FRRUS ≔ qz ⋅ GH ⋅ CaRRUS ⋅ Ka ⋅ SARRUSS = 67 lbs ⎛⎝LRRUS + 2 ⋅ tiz⎞⎠ ⋅ ⎛⎝WRRUS + 2 ⋅ tiz⎞⎠ SAICERRUSF ≔ ――――――――――― = 3.1 144 sf FiRRUS ≔ qzice ⋅ GH ⋅ CaRRUS ⋅ Ka ⋅ SAICERRUSF = 33 lbs ⎛⎝L RRUS + 2 ⋅ tiz⎞⎠ ⋅ ⎛⎝TRRUS + 2 ⋅ tiz⎞⎠ SAICERRUSS ≔ ――――――――――― = 2.5 144 sf FiRRUS ≔ qzice ⋅ GH ⋅ CaRRUS ⋅ Ka ⋅ SAICERRUSS = 27 lbs WTRRUS ⋅ NRRUS = 109 lbs VRRUS ≔ LRRUS ⋅ WRRUS ⋅ TRRUS = 3723 cu in Wind Load (with ice) Surface Area for One RRUS w/ Ice = Total RRUS Wind Force w/ Ice = Surface Area for One RRUS w/ Ice = Total RRUS Wind Force w/ Ice = Gravity Load (without ice) Weight of All RRUSs = Gravity Loads (ice only) Volume of Each RRUS = Volume of Ice on Each RRUS = Vice ≔ ⎛⎝L RRUS + 2 ⋅ tiz⎞⎠ ⋅ ⎛⎝WRRUS + 2 ⋅ tiz⎞⎠ ⋅ ⎛⎝TRRUS + 2 ⋅ tiz⎞⎠ - VRRUS = 3142 Weight of Ice on Each RRUS = Vice WICERRUS ≔ ――⋅ Id = 102 1728 lbs WICERRUS ⋅ NRRUS = 102 lbs cu in Weight of Ice on All RRUSs = CTNH568A_TIA RevG Load Calculations Rev.1.mcdx Page 5 Y Z X N49 N51 N34 N47 N31 L2.5x2. 5x 5 N89 N36 N92 N79 N53 PIPE_2.0 PIPE_2.0 N45 N43 N24 N83 N35 N86 N71 PIPE_2.0 N65 N95 N77 .0 N48 5x5 HS HS S4 X4 X4 HSS4X4 X4 N41 N84 " 4X PIPE_2.0 4 N9 N97 S4 X N46 HS N3 PIPE_2.0 N7 N1 PIPE_2.0 PIPE_2 N10 N39 4X 4 PIP N12 N6 N5 N94 N75 HSN54 N73 S4 X4 X4 X4 X4 S4 HS N32 N29 N78 N93 N76 PIPE_2.0 PIPE_2.0 PIP E_ 3.0 N14N50 x3x 0 N74 N85 6"x N26 3/8 " N2 N21 N18 N42 N90 N52 E_ 3.0 PIPE_2.0 N72 N15 4X4 LL2x2 N30 HSS4X 4X4 L2.5 x2. X4 N59 HSS4X N37 N16 PIPE_2.0 4 4X N61 PIPE_2.0 N63 S HS N81 N33 N40 S4 X PIP E_ 2.0 N22 /8"N19 6"x3 N13 N25 PIPE_2.0 N80 N57 N82 N91L2.5 x2 .5x 5 PIP E_ 2.0 6 "x 3/8 N55 N38 N100 L PIPE_3 x0 2x3 L2x N70 N87 N23 N8 N28 N20 N17 N11 N69 .0 N44 N56 N96 LL2 x 2x3x 0 N68 N4 N99 N27 N88 N67 N98 N66 N64 N58 N62 N60 Envelope Only Solution Centek Engineering FJP 21085.03 CTNH568A - Mount Member Framing Jan 3, 2022 at 9:51 AM CTNH568A_AMA Rev1.R3D Company Designer Job Number Model Name : : : : Centek Engineering FJP 21085.03 CTNH568A - Mount Jan 3, 2022 9:50 AM Checked By: TJL (Global) Model Settings Display Sections for Member Calcs Max Internal Sections for Member Calcs Include Shear Deformation? Increase Nailing Capacity for Wind? Include Warping? Trans Load Btwn Intersecting Wood Wall? Area Load Mesh (in^2) Merge Tolerance (in) P-Delta Analysis Tolerance Include P-Delta for Walls? Automatically Iterate Stiffness for Walls? Max Iterations for Wall Stiffness Gravity Acceleration (ft/sec^2) Wall Mesh Size (in) Eigensolution Convergence Tol. (1.E-) Vertical Axis Global Member Orientation Plane Static Solver Dynamic Solver 5 97 Yes Yes Yes Yes 144 .12 0.50% Yes Yes 3 32.2 12 4 Y XZ Sparse Accelerated Accelerated Solver Hot Rolled Steel Code Adjust Stiffness? RISAConnection Code Cold Formed Steel Code Wood Code Wood Temperature Concrete Code Masonry Code Aluminum Code Stainless Steel Code Adjust Stiffness? AISC 15th(360-16): LRFD Yes(Iterative) AISC 14th(360-10): ASD AISI S100-10: ASD AWC NDS-12: ASD < 100F ACI 318-11 ACI 530-11: ASD AA ADM1-10: ASD - Building AISC 14th(360-10): ASD Yes(Iterative) Number of Shear Regions Region Spacing Increment (in) Biaxial Column Method Parme Beta Factor (PCA) Concrete Stress Block Use Cracked Sections? Use Cracked Sections Slab? Bad Framing Warnings? Unused Force Warnings? Min 1 Bar Diam. Spacing? Concrete Rebar Set Min % Steel for Column Max % Steel for Column 4 4 Exact Integration .65 Rectangular Yes Yes No Yes No REBAR_SET_ASTMA615 1 8 RISA-3D Version 17.0.0 [J:\...\...\...\...\...\...\Risa 3D\CTNH568A_AMA Rev1.R3D] Page 1 Company Designer Job Number Model Name : : : : Centek Engineering FJP 21085.03 CTNH568A - Mount Jan 3, 2022 9:50 AM Checked By: TJL (Global) Model Settings, Continued Seismic Code Seismic Base Elevation (ft) Add Base Weight? Ct X Ct Z T X (sec) T Z (sec) RX RZ Ct Exp. X Ct Exp. Z SD1 SDS S1 TL (sec) Risk Cat Drift Cat Om Z Om X Cd Z Cd X Rho Z Rho X ASCE 7-10 Not Entered Yes .02 .02 Not Entered Not Entered 3 3 .75 .75 1 1 1 5 I or II Other 1 1 1 1 1 1 Footing Overturning Safety Factor Optimize for OTM/Sliding Check Concrete Bearing Footing Concrete Weight (k/ft^3) Footing Concrete f'c (ksi) Footing Concrete Ec (ksi) Lambda Footing Steel fy (ksi) Minimum Steel Maximum Steel Footing Top Bar Footing Top Bar Cover (in) Footing Bottom Bar Footing Bottom Bar Cover (in) Pedestal Bar Pedestal Bar Cover (in) Pedestal Ties 1 No No 150.001 4 3644 1 60 0.0018 0.0075 #3 2 #3 3.5 #3 1.5 #3 Hot Rolled Steel Properties 1 2 3 4 5 6 Label E [ksi] G [ksi] Nu A36 Gr.36 A572 Gr.50 A992 A500 Gr.42 A500 Gr.46 A53 Grade B 29000 29000 29000 29000 29000 29000 11154 11154 11154 11154 11154 11154 .3 .3 .3 .3 .3 .3 RISA-3D Version 17.0.0 Therm (\... Density[k/ft^3] .65 .65 .65 .65 .65 .65 .49 .49 .49 .49 .49 .49 Yield[ksi] Ry Fu[ksi] Rt 36 50 50 42 46 35 1.5 1.1 1.1 1.3 1.2 1.5 58 58 58 58 58 58 1.2 1.2 1.2 1.1 1.1 1.2 [J:\...\...\...\...\...\...\Risa 3D\CTNH568A_AMA Rev1.R3D] Page 2 Company Designer Job Number Model Name : : : : Centek Engineering FJP 21085.03 CTNH568A - Mount Jan 3, 2022 9:50 AM Checked By: TJL Hot Rolled Steel Section Sets 1 2 3 4 5 6 7 8 Label Shape Type Design List Outrigger_HSS4X4 HSS4X4X4 PIPE_3.0 PIPE_2.0 PIPE_2.0 HSS4X4X4 6"x3/8" L2.5x2.5x5 LL2x2x3x0 Beam Beam Beam HSS Pipe Pipe Pipe Pipe HSS Pipe RECT RECT RECT Face Tube_Pipe 3.0 S... Handrails _Pipe 2.0 STD Antenna Mast_Pipe 2.0... Plat. Horz_HSS4X4 PL 3/8"x6 " Side railings Mount Reinforcement Column Beam Beam Beam Beam Material Design Ru... A [in2] Iyy [in4]Izz [in4] J [in4] A500 Gr.46 Typical 3.37 7.8 7.8 12.8 A53 Grade B Typical 2.07 2.85 2.85 5.69 A53 Grade B Typical 1.02 .627 .627 1.25 A53 Grade B Typical 1.02 .627 .627 1.25 A500 Gr.46 Typical 3.37 7.8 7.8 12.8 A36 Gr.36 Typical A36 Gr.36 Typical A36 Gr.36 Typical 2.25 .026 6.75 .101 1.46 .837 .837 .05 1.44 .994 .542 .018 Hot Rolled Steel Design Parameters Label 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 Shape Length[ft] Outrigger_HSS4X4 5.248 M1 Plat. Horz_HSS4X4 2.75 M2 Plat. Horz_HSS4X4 2.75 M3 Outrigger_HSS4X4 5.248 M4 Plat. Horz_HSS4X4 2.75 M5 Plat. Horz_HSS4X4 2.75 M6 Outrigger_HSS4X4 5.248 M7 Plat. Horz_HSS4X4 2.75 M8 Plat. Horz_HSS4X4 2.75 M9 Face Tube_Pipe 3.0... 12.5 M10 Face Tube_Pipe 3.0... 12.5 M13 M14 Face Tube_Pipe 3.0... 12.5 M13A PL 3/8"x6 " 1.212 M14A PL 3/8"x6 " 1.212 M15 PL 3/8"x6 " 1.212 M16 Handrails _Pipe 2.0... 12.5 M17 Handrails _Pipe 2.0... 12.5 M18 Handrails _Pipe 2.0... 12.5 PSA.1 Antenna Mast_Pipe... 8 PSA.2 Antenna Mast_Pipe... 8 PSA.3 Antenna Mast_Pipe... 8 PSA.4 Antenna Mast_Pipe... 8 PSB.1 Antenna Mast_Pipe... 8 PSB.2 Antenna Mast_Pipe... 8 PSB.3 Antenna Mast_Pipe... 8 PSB.4 Antenna Mast_Pipe... 8 PSC.1 Antenna Mast_Pipe... 8 PSC.2 Antenna Mast_Pipe... 8 PSC.3 Antenna Mast_Pipe... 8 PSC.4 Antenna Mast_Pipe... 8 M31 Side railings 1.712 M32 Side railings 1.712 M33 Side railings 1.712 M34 Mount Reinforcement 4.991 M35 Mount Reinforcement 4.991 M36 Mount Reinforcement 4.991 RISA-3D Version 17.0.0 Lbyy[ft] Lbzz[ft] Lcomp top[...Lcomp bot[...L-torq... Lbyy Lbyy Lbyy Lbyy Lbyy Lbyy Lbyy Lbyy Lbyy Lbyy Lbyy Lbyy Lbyy Lbyy Lbyy Lbyy Lbyy Lbyy Lbyy Lbyy Lbyy Lbyy Lbyy Lbyy Lbyy Lbyy Lbyy Lbyy Lbyy Lbyy Lbyy Lbyy Lbyy Lbyy Lbyy Lbyy [J:\...\...\...\...\...\...\Risa 3D\CTNH568A_AMA Rev1.R3D] Kyy Kzz Cb Functi... Lateral Lateral Lateral Lateral Lateral Lateral Lateral Lateral Lateral Lateral Lateral Lateral Lateral Lateral Lateral Lateral Lateral Lateral Lateral Lateral Lateral Lateral Lateral Lateral Lateral Lateral Lateral Lateral Lateral Lateral Lateral Lateral Lateral Lateral Lateral Lateral Page 3 Company Designer Job Number Model Name : : : : Centek Engineering FJP 21085.03 CTNH568A - Mount Jan 3, 2022 9:50 AM Checked By: TJL Member Primary Data 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 Label I Joint J Joint M1 M2 M3 M4 M5 M6 M7 M8 M9 M10 M13 M14 M13A M14A M15 M16 M17 M18 PSA.1 PSA.2 PSA.3 PSA.4 PSB.1 PSB.2 PSB.3 PSB.4 PSC.1 PSC.2 PSC.3 PSC.4 M31 M32 M33 M34 M35 M36 N1 N4 N5 N7 N10 N11 N12 N15 N16 N17 N19 N21 N28 N24 N27 N29 N31 N33 N43 N45 N47 N49 N51 N53 N55 N57 N59 N61 N63 N65 N91 N93 N89 N97 N95 N96 N2 N3 N3 N8 N9 N9 N13 N14 N14 N18 N20 N22 N23 N25 N26 N30 N32 N34 N44 N46 N48 N50 N52 N54 N56 N58 N60 N62 N64 N66 N94 N90 N92 N99 N100 N98 K Joint Rotate(... 180 180 180 Section/Shape Type Outrigger_HSS4X4 Plat. Horz_HSS4X4 Plat. Horz_HSS4X4 Outrigger_HSS4X4 Plat. Horz_HSS4X4 Plat. Horz_HSS4X4 Outrigger_HSS4X4 Plat. Horz_HSS4X4 Plat. Horz_HSS4X4 Beam Beam Beam Beam Beam Beam Beam Beam Beam Beam Beam Beam Beam Beam Beam Beam Beam Beam Column Column Column Column Column Column Column Column Column Column Column Column Beam Beam Beam Beam Beam Beam Face Tube_Pipe 3.0 STD Face Tube_Pipe 3.0 STD Face Tube_Pipe 3.0 STD PL 3/8"x6 " PL 3/8"x6 " PL 3/8"x6 " Handrails _Pipe 2.0 STD Handrails _Pipe 2.0 STD Handrails _Pipe 2.0 STD Antenna Mast_Pipe 2.0 S... Antenna Mast_Pipe 2.0 S... Antenna Mast_Pipe 2.0 S... Antenna Mast_Pipe 2.0 S... Antenna Mast_Pipe 2.0 S... Antenna Mast_Pipe 2.0 S... Antenna Mast_Pipe 2.0 S... Antenna Mast_Pipe 2.0 S... Antenna Mast_Pipe 2.0 S... Antenna Mast_Pipe 2.0 S... Antenna Mast_Pipe 2.0 S... Antenna Mast_Pipe 2.0 S... 180 180 180 Side railings Side railings Side railings Mount Reinforcement Mount Reinforcement Mount Reinforcement Design List HSS Pipe HSS Pipe HSS Pipe HSS Pipe HSS Pipe HSS Pipe HSS Pipe HSS Pipe HSS Pipe Pipe Pipe Pipe RECT RECT RECT Pipe Pipe Pipe Pipe Pipe Pipe Pipe Pipe Pipe Pipe Pipe Pipe Pipe Pipe Pipe RECT RECT RECT RECT RECT RECT Material Design ... A500 Gr.46 A500 Gr.46 A500 Gr.46 A500 Gr.46 A500 Gr.46 A500 Gr.46 A500 Gr.46 A500 Gr.46 A500 Gr.46 A53 Grade B A53 Grade B A53 Grade B A36 Gr.36 A36 Gr.36 A36 Gr.36 A53 Grade B A53 Grade B A53 Grade B A53 Grade B A53 Grade B A53 Grade B A53 Grade B A53 Grade B A53 Grade B A53 Grade B A53 Grade B A53 Grade B A53 Grade B A53 Grade B A53 Grade B A36 Gr.36 A36 Gr.36 A36 Gr.36 A36 Gr.36 A36 Gr.36 A36 Gr.36 Typical Typical Typical Typical Typical Typical Typical Typical Typical Typical Typical Typical Typical Typical Typical Typical Typical Typical Typical Typical Typical Typical Typical Typical Typical Typical Typical Typical Typical Typical Typical Typical Typical Typical Typical Typical Joint Coordinates and Temperatures 1 2 3 4 5 6 7 8 9 10 Label X [ft] Y [ft] Z [ft] Temp [F] N1 N2 N3 N4 N5 N6 N7 N8 N9 N10 -0. -0. -0. 2.75 -2.75 -0. 1.341329 5.886307 2.670245 1.295245 0 0 0 0 0 0 0 0 0 0 1.548833 6.796922 3.083333 3.083333 3.083333 0. -0.774417 -3.398461 -1.541667 -3.923237 0 0 0 0 0 0 0 0 0 0 RISA-3D Version 17.0.0 [J:\...\...\...\...\...\...\Risa 3D\CTNH568A_AMA Rev1.R3D] Detach From Diap... Page 4 Company Designer Job Number Model Name : : : : Centek Engineering FJP 21085.03 CTNH568A - Mount Jan 3, 2022 9:50 AM Checked By: TJL Joint Coordinates and Temperatures (Continued) 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 Label X [ft] Y [ft] Z [ft] Temp [F] N11 N12 N13 N14 N15 N16 N17 N18 N19 N20 N21 N22 N23 N24 N25 N26 N27 N28 N29 N30 N31 N32 N33 N34 N35 N36 N37 N38 N39 N40 N41 N42 N43 N44 N45 N46 N47 N48 N49 N50 N51 N52 N53 N54 N55 N56 N57 N58 N59 N60 N61 N62 4.045245 -1.341329 -5.886307 -2.670245 -4.045245 -1.295245 6.52262 0.272625 -6.249995 6.249995 -0.272625 -6.52262 5.583328 -5.583328 -6.189287 -0.605958 0.605958 6.189287 6.52262 0.272625 -6.249995 6.249995 -0.272625 -6.52262 -4.666662 -4.666662 -1.687495 -1.687495 1.645838 1.645838 4.770838 4.770838 4.770838 4.770838 1.645838 1.645838 -1.687495 -1.687495 -4.666662 -4.666662 -5.783042 -5.783042 -4.220542 -4.220542 -2.553875 -2.553875 -1.064292 -1.064292 1.012203 1.012203 2.574703 2.574703 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 3.45 3.45 3.45 3.45 3.45 3.45 0 3.45 0 3.45 0 3.45 0 3.45 5.75 -2.25 5.75 -2.25 5.75 -2.25 5.75 -2.25 5.75 -2.25 5.75 -2.25 5.75 -2.25 5.75 -2.25 5.75 -2.25 5.75 -2.25 0.839903 -0.774417 -3.398461 -1.541667 0.839903 -3.923237 -3.451036 7.374273 -3.923237 -3.923237 7.374273 -3.451036 -3.923237 -3.923237 -2.873686 6.796922 6.796922 -2.873686 -3.451036 7.374273 -3.923237 -3.923237 7.374273 -3.451036 -3.923237 -3.923237 -3.923237 -3.923237 -3.923237 -3.923237 -3.923237 -3.923237 -3.923237 -3.923237 -3.923237 -3.923237 -3.923237 -3.923237 -3.923237 -3.923237 -2.170049 -2.170049 0.53628 0.53628 3.423032 3.423032 6.003066 6.003066 6.093285 6.093285 3.386956 3.386956 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 RISA-3D Version 17.0.0 [J:\...\...\...\...\...\...\Risa 3D\CTNH568A_AMA Rev1.R3D] Detach From Diap... Page 5 Company Designer Job Number Model Name : : : : Centek Engineering FJP 21085.03 CTNH568A - Mount Jan 3, 2022 9:50 AM Checked By: TJL Joint Coordinates and Temperatures (Continued) 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100 Label X [ft] Y [ft] Z [ft] Temp [F] N63 N64 N65 N66 N67 N68 N69 N70 N71 N72 N73 N74 N75 N76 N77 N78 N79 N80 N81 N82 N83 N84 N85 N86 N87 N88 N89 N90 N91 N92 N93 N94 N95 N96 N97 N98 N99 N100 4.24137 4.24137 5.730953 5.730953 1.012203 2.574703 4.24137 5.730953 -5.783042 -4.220542 -2.553875 -1.064292 1.012203 2.574703 4.24137 5.730953 -5.783042 -4.220542 -2.553875 -1.064292 -5.083328 5.083328 -0.855958 -5.939287 5.939287 0.855958 -5.083328 5.083328 -0.855958 -5.939287 5.939287 0.855958 -4.763371 -0. 4.763371 -0. 1.341329 -1.341329 5.75 -2.25 5.75 -2.25 0 0 0 0 0 0 0 0 3.45 3.45 3.45 3.45 3.45 3.45 3.45 3.45 0 0 0 0 0 0 3.45 3.45 3.45 3.45 3.45 3.45 0 0 0 -3.049275 -3.049275 -3.049275 0.500205 0.500205 -2.079829 -2.079829 6.093285 3.386956 0.500205 -2.079829 -2.170049 0.53628 3.423032 6.003066 6.093285 3.386956 0.500205 -2.079829 -2.170049 0.53628 3.423032 6.003066 -3.923237 -3.923237 6.36391 -2.440673 -2.440673 6.36391 -3.923237 -3.923237 6.36391 -2.440673 -2.440673 6.36391 -2.750133 5.500267 -2.750133 1.548833 -0.774417 -0.774417 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 Detach From Diap... Joint Boundary Conditions 1 2 3 4 5 6 7 8 9 Joint Label X [k/in] Y [k/in] Z [k/in] N1 N7 N12 N95 N96 N97 N98 N99 N100 Reaction Reaction Reaction Reaction Reaction Reaction Reaction Reaction Reaction Reaction Reaction Reaction Reaction Reaction Reaction Reaction Reaction Reaction Reaction Reaction Reaction Reaction Reaction Reaction RISA-3D Version 17.0.0 X Rot.[k-ft/rad] [J:\...\...\...\...\...\...\Risa 3D\CTNH568A_AMA Rev1.R3D] Y Rot.[k-ft/rad] Z Rot.[k-ft/rad] Page 6 Company Designer Job Number Model Name : : : : Centek Engineering FJP 21085.03 CTNH568A - Mount Jan 3, 2022 9:50 AM Checked By: TJL Member Point Loads (BLC 2 : Equipment Weight) 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 Member Label Direction Magnitude[k,k-ft] Location[ft,%] PSA.1 PSA.1 PSA.4 PSA.4 PSA.1 PSA.1 PSC.1 PSC.1 PSC.4 PSC.4 PSC.1 PSC.1 PSB.1 PSB.1 PSB.4 PSB.4 PSB.1 PSB.1 Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y -.075 -.075 -.052 -.052 -.084 -.109 -.075 -.075 -.052 -.052 -.084 -.109 -.075 -.075 -.052 -.052 -.084 -.109 1.083 5.917 1.667 4.417 1 7 1.083 5.917 1.667 4.417 1 7 1.083 5.917 1.667 4.417 1 7 Member Point Loads (BLC 3 : Ice Weight) 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 Member Label Direction Magnitude[k,k-ft] Location[ft,%] PSA.1 PSA.1 PSA.4 PSA.4 PSA.1 PSA.1 PSC.1 PSC.1 PSC.4 PSC.4 PSC.1 PSC.1 PSB.1 PSB.1 PSB.4 PSB.4 PSB.1 PSB.1 Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y -.211 -.211 -.076 -.076 -.088 -.102 -.211 -.211 -.076 -.076 -.088 -.102 -.211 -.211 -.076 -.076 -.088 -.102 1.083 5.917 1.667 4.417 1 7 1.083 5.917 1.667 4.417 1 7 1.083 5.917 1.667 4.417 1 7 Member Point Loads (BLC 4 : Wind w/ Ice X (8 psf)) 1 2 3 4 5 6 7 8 Member Label Direction Magnitude[k,k-ft] Location[ft,%] PSA.1 PSA.1 PSA.4 PSA.4 PSA.1 PSA.1 PSC.1 PSC.1 X X X X X X X X .047 .047 .016 .016 .021 .027 .108 .108 1.083 5.917 1.667 4.417 1 7 1.083 5.917 RISA-3D Version 17.0.0 [J:\...\...\...\...\...\...\Risa 3D\CTNH568A_AMA Rev1.R3D] Page 7 Company Designer Job Number Model Name : : : : Centek Engineering FJP 21085.03 CTNH568A - Mount Jan 3, 2022 9:50 AM Checked By: TJL Member Point Loads (BLC 4 : Wind w/ Ice X (8 psf)) (Continued) 9 10 11 12 13 14 15 16 17 18 Member Label Direction Magnitude[k,k-ft] Location[ft,%] PSC.4 PSC.4 PSC.1 PSC.1 PSB.1 PSB.1 PSB.4 PSB.4 PSB.1 PSB.1 X X X X X X X X X X .033 .033 .036 .033 .108 .108 .033 .033 .036 .033 1.667 4.417 1 7 1.083 5.917 1.667 4.417 1 7 Member Point Loads (BLC 5 : Wind X(31 psf)) 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 Member Label Direction Magnitude[k,k-ft] Location[ft,%] PSA.1 PSA.1 PSA.4 PSA.4 PSA.1 PSA.1 PSC.1 PSC.1 PSC.4 PSC.4 PSC.1 PSC.1 PSB.1 PSB.1 PSB.4 PSB.4 PSB.1 PSB.1 X X X X X X X X X X X X X X X X X X .122 .122 .039 .039 .046 .067 .343 .343 .096 .096 .097 .087 .343 .343 .096 .096 .097 .087 1.083 5.917 1.667 4.417 1 7 1.083 5.917 1.667 4.417 1 7 1.083 5.917 1.667 4.417 1 7 Member Point Loads (BLC 6 : Wind w/ Ice Z(8 psf)) 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 Member Label Direction Magnitude[k,k-ft] Location[ft,%] PSA.1 PSA.1 PSA.4 PSA.4 PSA.1 PSA.1 PSC.1 PSC.1 PSC.4 PSC.4 PSC.1 PSC.1 PSB.1 PSB.1 PSB.4 PSB.4 PSB.1 Z Z Z Z Z Z Z Z Z Z Z Z Z Z Z Z Z .108 .108 .033 .033 .036 .033 .108 .108 .033 .033 .036 .033 .047 .047 .016 .016 .021 1.083 5.917 1.667 4.417 1 7 1.083 5.917 1.667 4.417 1 7 1.083 5.917 1.667 4.417 1 RISA-3D Version 17.0.0 [J:\...\...\...\...\...\...\Risa 3D\CTNH568A_AMA Rev1.R3D] Page 8 Company Designer Job Number Model Name : : : : Centek Engineering FJP 21085.03 CTNH568A - Mount Jan 3, 2022 9:50 AM Checked By: TJL Member Point Loads (BLC 6 : Wind w/ Ice Z(8 psf)) (Continued) 18 Member Label Direction Magnitude[k,k-ft] Location[ft,%] PSB.1 Z .027 7 Member Point Loads (BLC 7 : Wind Z (31 psf)) 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 Member Label Direction Magnitude[k,k-ft] Location[ft,%] PSA.1 PSA.1 PSA.4 PSA.4 PSA.1 PSA.1 PSC.1 PSC.1 PSC.4 PSC.4 PSC.1 PSC.1 PSB.1 PSB.1 PSB.4 PSB.4 PSB.1 PSB.1 Z Z Z Z Z Z Z Z Z Z Z Z Z Z Z Z Z Z .343 .343 .096 .096 .097 .087 .122 .122 .039 .039 .046 .067 .122 .122 .039 .039 .046 .067 1.083 5.917 1.667 4.417 1 7 1.083 5.917 1.667 4.417 1 7 1.083 5.917 1.667 4.417 1 7 Member Distributed Loads (BLC 4 : Wind w/ Ice X (8 psf)) 1 2 3 4 5 6 7 8 9 10 11 12 13 Member Label Direction Start Magnitude[k/ft,F,ksf] M34 M35 M36 PSA.2 PSA.3 PSB.2 PSB.3 PSC.2 PSC.3 M16 M18 M10 M14 X X X X X X X X X X X X X .001 .001 .001 .002 .002 .002 .002 .002 .002 .002 .002 .002 .002 End Magnitude[k/f...Start Location[ft,%] End Location[ft,%] .001 .001 .001 .002 .002 .002 .002 .002 .002 .002 .002 .002 .002 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 Member Distributed Loads (BLC 5 : Wind X(31 psf)) 1 2 3 4 5 6 7 8 Member Label Direction Start Magnitude[k/ft,F,ksf] M34 M35 M36 PSA.2 PSA.3 PSB.2 PSB.3 PSC.2 X X X X X X X X .005 .005 .005 .006 .006 .006 .006 .006 RISA-3D Version 17.0.0 End Magnitude[k/f...Start Location[ft,%] End Location[ft,%] .005 .005 .005 .006 .006 .006 .006 .006 [J:\...\...\...\...\...\...\Risa 3D\CTNH568A_AMA Rev1.R3D] 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 Page 9 Company Designer Job Number Model Name : : : : Centek Engineering FJP 21085.03 CTNH568A - Mount Jan 3, 2022 9:50 AM Checked By: TJL Member Distributed Loads (BLC 5 : Wind X(31 psf)) (Continued) 9 10 11 12 13 Member Label Direction Start Magnitude[k/ft,F,ksf] PSC.3 M16 M18 M10 M14 X X X X X .006 .006 .006 .009 .009 End Magnitude[k/f...Start Location[ft,%] End Location[ft,%] .006 .006 .006 .009 .009 0 0 0 0 0 0 0 0 0 0 Member Distributed Loads (BLC 6 : Wind w/ Ice Z(8 psf)) 1 2 3 4 5 6 7 8 9 10 Member Label Direction Start Magnitude[k/ft,F,ksf] M34 M35 PSA.2 PSA.3 PSB.2 PSB.3 PSC.2 PSC.3 M13 M17 Z Z Z Z Z Z Z Z Z Z .001 .001 .002 .002 .002 .002 .002 .002 .002 .002 End Magnitude[k/f...Start Location[ft,%] End Location[ft,%] .001 .001 .002 .002 .002 .002 .002 .002 .002 .002 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 Member Distributed Loads (BLC 7 : Wind Z (31 psf)) 1 2 3 4 5 6 7 8 9 10 Member Label Direction Start Magnitude[k/ft,F,ksf] M34 M35 PSC.3 PSC.2 PSB.3 PSB.2 PSA.3 PSA.2 M17 M13 Z Z Z Z Z Z Z Z Z Z .005 .005 .006 .006 .006 .006 .006 .006 .006 .009 End Magnitude[k/f...Start Location[ft,%] End Location[ft,%] .005 .005 .006 .006 .006 .006 .006 .006 .006 .009 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 Member Distributed Loads (BLC 8 : BLC 2 Transient Area Loads) 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 Member Label Direction Start Magnitude[k/ft,F,ksf] M1 M1 M1 M2 M3 M10 M10 M10 M14 M14 M14 M15 M7 M7 M7 M8 Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y -.015 -.007 -.004 -.004 -.004 -.00071 -.003 -.003 -.0004575 -.003 -.003 -.0008711 -.015 -.007 -.004 -.004 RISA-3D Version 17.0.0 End Magnitude[k/f...Start Location[ft,%] End Location[ft,%] -.007 -.004 -.005 -.004 -.004 -.003 -.003 -.0004574 -.003 -.003 -.0007098 -.0008711 -.007 -.004 -.005 -.004 [J:\...\...\...\...\...\...\Risa 3D\CTNH568A_AMA Rev1.R3D] 2.099 3.149 4.198 .169 .169 7.5 9.167 10.833 0 1.667 3.333 0 2.099 3.149 4.198 .169 3.149 4.198 5.248 2.704 2.704 9.167 10.833 12.5 1.667 3.333 5 1.212 3.149 4.198 5.248 2.704 Page 10 Company Designer Job Number Model Name : : : : Centek Engineering FJP 21085.03 CTNH568A - Mount Jan 3, 2022 9:50 AM Checked By: TJL Member Distributed Loads (BLC 8 : BLC 2 Transient Area Loads) (Continued) 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 Member Label Direction Start Magnitude[k/ft,F,ksf] M9 M13 M13 M13 M14 M14 M14 M14A M4 M4 M4 M5 M6 M10 M10 M10 M13 M13 M13 M13A Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y -.004 -.0004575 -.003 -.003 -.00071 -.003 -.003 -.0008711 -.015 -.007 -.004 -.004 -.004 -.0004575 -.003 -.003 -.00071 -.003 -.003 -.0008711 End Magnitude[k/f...Start Location[ft,%] End Location[ft,%] -.004 -.003 -.003 -.0007098 -.003 -.003 -.0004574 -.0008711 -.007 -.004 -.005 -.004 -.004 -.003 -.003 -.0007098 -.003 -.003 -.0004574 -.0008711 .169 0 1.667 3.333 7.5 9.167 10.833 0 2.099 3.149 4.198 .169 .169 0 1.667 3.333 7.5 9.167 10.833 0 2.704 1.667 3.333 5 9.167 10.833 12.5 1.212 3.149 4.198 5.248 2.704 2.704 1.667 3.333 5 9.167 10.833 12.5 1.212 Basic Load Cases 1 2 3 4 5 6 7 8 BLC Description Category Self Weight Equipment Weight Ice Weight Wind w/ Ice X (8 psf) Wind X(31 psf) Wind w/ Ice Z(8 psf) Wind Z (31 psf) BLC 2 Transient Area Loads None None None None None None None None X Gra...Y Gra...Z Gra... Joint Point Distrib...Area(... Surfa... -1 18 18 18 18 18 18 3 13 13 10 10 36 Load Combinations 1 2 3 4 5 6 Description Sol...PD...SR...BLC Fact...BLC Fact...BLC Fact...BLC Fact...BLC Fact...BLC Fact...BLC Fact...BLC Fact...BLC Fact...BLC Fact... 1.2D + 1.6...Yes Y 1 1.2 2 1.2 5 1.6 0.9D + 1.6...Yes Y 1 .9 2 .9 5 1.6 1.2D + 1.0...Yes Y 1 1.2 2 1.2 3 1 4 1 1.2D + 1.6...Yes Y 1 1.2 2 1.2 7 1.6 0.9D + 1.6...Yes Y 1 .9 2 .9 7 1.6 1.2D + 1.0...Yes Y 1 1.2 2 1.2 3 1 6 1 Envelope Joint Reactions Joint 1 2 3 4 N1 N7 max min max min RISA-3D Version 17.0.0 X [k] LC Y [k] LC Z [k] LC MX [k-ft] LC MY [k-ft] LC MZ [k-ft] LC .071 -2.419 -.41 -3.572 5 1 5 1 .103 -.209 .278 -.262 1 5 4 2 -1.291 -3.707 1.914 -1.828 2 4 1 5 0 0 0 0 6 1 6 1 .17 -3.39 2.267 -.038 4 1 4 2 0 0 0 0 6 1 6 1 [J:\...\...\...\...\...\...\Risa 3D\CTNH568A_AMA Rev1.R3D] Page 11 Company Designer Job Number Model Name : : : : Centek Engineering FJP 21085.03 CTNH568A - Mount Jan 3, 2022 9:50 AM Checked By: TJL Envelope Joint Reactions (Continued) Joint 5 6 7 8 9 10 11 12 13 14 N12 N98 N99 N100 Totals: max min max min max min max min max min X [k] LC Y [k] LC Z [k] LC MX [k-ft] LC MY [k-ft] LC MZ [k-ft] LC 1.802 -2.305 0 -.019 2.466 .219 .559 -1.827 0 -5.291 6 2 6 2 1 5 2 6 6 1 .476 .115 2.082 .742 2.23 .206 1.642 -.506 5.594 2.477 1 6 6 2 1 5 6 2 6 2 .946 -.736 2.68 .948 -.147 -1.436 .336 -1.058 0 -3.945 3 5 6 2 5 1 2 6 3 4 0 0 0 0 0 0 0 0 6 1 6 1 6 1 6 1 .613 -1.048 0 -.002 .002 0 0 0 1 4 6 2 4 2 1 5 0 0 0 0 0 0 0 0 6 1 6 1 6 1 6 1 Envelope Joint Displacements Joint 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 N1 max min N2 max min N3 max min N4 max min N5 max min N6 max min N7 max min N8 max min N9 max min N10 max min N11 max min N12 max min N13 max min N14 max min N15 max min N16 max min N17 max min N18 max min N19 max X [in] LC Y [in] LC Z [in] LC X Rotation [rad] 0 0 .167 .003 .027 -.002 .027 -.002 .027 -.001 0 0 0 0 .067 .003 .008 0 .015 -.002 .038 -.017 0 0 .036 -.029 .002 -.004 .059 .001 .014 -.002 .12 .01 .189 .002 .015 6 1 2 6 1 4 1 4 2 4 6 1 6 1 4 3 4 2 2 5 2 5 6 1 2 4 2 4 2 6 2 5 4 3 2 4 2 0 0 -.02 -.04 .002 -.008 -.037 -.05 .034 -.014 0 0 0 0 -.003 -.038 -.001 -.01 .021 -.038 -.019 -.04 0 0 .006 -.035 .004 -.001 .033 -.03 .025 -.03 .007 -.023 -.014 -.047 .011 6 1 2 6 2 4 3 4 2 4 6 1 6 1 5 3 5 1 5 1 3 4 6 1 2 6 5 3 2 6 5 1 5 3 2 6 2 0 0 .002 0 0 0 .038 -.031 .049 .004 0 0 0 0 .115 .002 .015 -.001 .021 -.009 .03 -.024 0 0 .05 -.061 .007 -.003 .03 .003 .008 .001 .109 -.019 .062 .013 .074 6 1 4 2 4 2 4 2 2 6 6 1 6 1 5 3 5 1 5 2 4 2 6 1 5 1 5 1 2 6 4 3 4 2 2 3 5 3.819e-04 -9.584e-05 1.942e-03 1.045e-03 5.61e-04 -1.619e-04 6.136e-03 1.615e-03 1.181e-03 -7.534e-03 0 0 5.509e-04 -4.465e-04 -7.961e-04 -2.638e-03 6.654e-04 -4.576e-04 1.749e-02 -3.058e-03 8.889e-03 1.705e-03 5.884e-04 -7.172e-04 7.657e-04 -4.222e-04 7.048e-04 -5.1e-04 3.629e-03 -1.267e-02 1.605e-02 -7.889e-03 1.122e-02 1.404e-03 1.161e-02 2.336e-04 1.774e-02 RISA-3D Version 17.0.0 LC Y Rotatio... LC Z Rotation [rad] LC 4 2 6 2 4 2 1 6 4 1 6 1 5 3 5 3 5 1 4 2 4 3 4 2 3 5 4 2 5 1 4 1 4 3 2 6 4 [J:\...\...\...\...\...\...\Risa 3D\CTNH568A_AMA Rev1.R3D] 0 0 3.468e-03 1.245e-04 1.876e-03 -1.421e-04 1.398e-03 2.86e-04 8.096e-04 -3.028e-04 0 0 0 0 -8.225e-05 -2.968e-03 1.673e-04 -1.092e-03 2.936e-04 -1.928e-03 -9.985e-05 -8.979e-04 0 0 1.255e-03 -1.866e-03 5.208e-04 -5.196e-05 3.54e-04 -2.225e-03 6.339e-04 -4.526e-04 1.545e-04 -3.025e-03 3.034e-03 -2.633e-04 1.144e-03 6 1 2 6 2 4 2 3 2 5 6 1 6 1 3 4 2 4 2 5 6 2 6 1 5 1 5 1 4 2 5 1 2 5 1 5 4 -5.572e-04 -9.903e-04 7.795e-04 -2.064e-03 -5.572e-04 -9.903e-04 -1.785e-03 -1.551e-02 2.743e-03 -2.043e-02 0 0 4.864e-05 -4.914e-04 2.96e-04 -6.186e-04 8.124e-05 -5.54e-04 3.411e-05 -3.025e-03 -2.05e-03 -1.068e-02 2.819e-04 -4.129e-04 2.37e-03 -1.591e-04 1.941e-04 -7.718e-04 4.69e-03 -1.564e-02 2.659e-03 -1.44e-03 -2.247e-03 -1.843e-02 -2.704e-03 -2.025e-02 -6.787e-05 Page 12 6 1 2 6 6 1 6 2 5 1 6 1 3 4 5 3 6 2 2 4 3 4 6 2 6 2 6 2 4 1 4 1 3 4 6 1 5 Company Designer Job Number Model Name : : : : Centek Engineering FJP 21085.03 CTNH568A - Mount Jan 3, 2022 9:50 AM Checked By: TJL Envelope Joint Displacements (Continued) Joint 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 min N20 max min N21 max min N22 max min N23 max min N24 max min N25 max min N26 max min N27 max min N28 max min N29 max min N30 max min N31 max min N32 max min N33 max min N34 max min N35 max min N36 max min N37 max min N38 max min N39 max min N40 max min N41 max min N42 max min N43 max min N44 max min N45 max X [in] LC Y [in] LC Z [in] LC X Rotation [rad] -.002 .015 -.002 .194 .004 .13 -.049 .015 -.002 .015 -.002 .127 -.041 .167 .003 .168 .003 .099 .01 1.393 .093 1.734 .084 .171 -.028 .171 -.029 1.702 .116 1.358 -.782 .015 -.002 .171 -.028 .015 -.002 .17 -.029 .015 -.002 .17 -.029 .015 -.002 .171 -.029 .331 -.013 .044 .013 .205 5 1 5 2 6 1 5 1 5 2 5 1 5 2 6 2 6 4 3 4 3 1 6 1 5 1 5 1 6 1 4 2 5 1 5 1 5 1 5 2 5 1 5 1 5 1 5 1 5 1 5 1 -.022 -.005 -.044 -.019 -.03 .009 -.04 -.009 -.054 .007 -.023 .006 -.048 -.018 -.029 -.014 -.056 .004 -.024 .055 -.047 .066 -.102 .06 -.044 -.03 -.121 -.039 -.106 .06 -.056 0 -.024 0 -.025 .014 -.024 .014 -.024 .01 -.039 .01 -.039 -.016 -.064 -.016 -.065 -.016 -.065 -.016 -.064 .01 6 5 3 5 1 2 6 5 3 2 6 2 6 5 1 2 6 5 3 5 1 2 4 2 4 5 1 6 1 2 3 2 6 2 6 5 1 5 1 5 3 5 3 5 3 5 3 5 3 5 3 5 -.087 .171 .002 .016 -.047 .047 -.011 .155 .001 .065 -.074 .043 -.009 .017 -.032 .05 .01 .097 -.018 .997 .028 .83 .125 .873 -1.412 1.706 .098 -.028 -.724 .593 -.524 .053 -.055 .909 -1.107 .011 0 .99 -.56 .03 -.01 1.229 -.097 .135 -.002 1.575 .065 2.957 .108 -.015 -.435 2.204 1 4 3 4 2 5 1 4 3 5 1 5 1 4 2 2 3 4 2 4 3 1 6 4 1 4 3 5 1 4 1 5 1 4 1 4 3 4 1 5 2 4 1 5 2 4 3 4 3 3 4 4 -1.571e-02 2.198e-02 5.227e-04 1.21e-04 -1.391e-02 5.637e-03 -1.059e-02 2.198e-02 5.227e-04 1.774e-02 -1.571e-02 5.638e-03 -1.059e-02 1.204e-04 -1.392e-02 1.161e-02 2.328e-04 1.123e-02 1.405e-03 1.945e-02 1.177e-03 1.986e-02 3.938e-03 2.346e-02 -2.656e-02 4.541e-02 1.532e-03 2.208e-04 -1.675e-02 1.331e-02 -1.769e-02 1.788e-02 -1.581e-02 2.354e-02 -2.672e-02 1.669e-02 -9.121e-03 2.785e-02 -1.559e-02 1.856e-02 -2.524e-03 3.517e-02 -2.602e-03 2.213e-02 5.599e-04 4.554e-02 1.537e-03 5.099e-02 1.547e-03 2.091e-02 5.561e-04 3.537e-02 RISA-3D Version 17.0.0 LC Y Rotatio... LC 1 -1.612e-03 2 4 -8.99e-05 3 3 -1.966e-03 4 5 3.847e-03 2 1 9.616e-05 6 4 1.099e-03 5 2 -4.321e-04 1 4 -8.99e-05 3 3 -1.965e-03 4 4 1.142e-03 4 1 -1.612e-03 2 4 1.099e-03 5 2 -4.307e-04 1 5 3.846e-03 2 1 9.616e-05 6 2 3.033e-03 1 6 -2.633e-04 5 4 1.559e-04 2 3 -3.025e-03 5 4 3 1 6 4 1 4 3 4 1 5 1 4 1 4 1 4 1 4 1 4 2 4 1 4 3 4 3 4 3 4 3 4 [J:\...\...\...\...\...\...\Risa 3D\CTNH568A_AMA Rev1.R3D] 7.01e-03 1 4 1 4 6 1 6 1 1 3 4 2 5 1 6 1 5 1 6 1 2 5 6 1 3 4 6 1 6 1 3 4 6 -1.536e-02 1.217e-02 -5.201e-03 -6.417e-04 -1.607e-02 -1.812e-03 -9.567e-03 9.531e-03 1.879e-03 9.207e-03 -1.563e-03 1.154e-03 -1.937e-03 -6.121e-04 -1.557e-02 7.863e-04 -9.682e-04 -9.101e-04 -1.26e-02 1.557e-05 -2.386e-03 -1.944e-03 -9.774e-03 -1.228e-04 -2.384e-03 -1.843e-03 -9.399e-03 -1.843e-03 -9.399e-03 -1.228e-04 -2.384e-03 -1.944e-03 Z Rotation [rad] LC -6.309e-04 1.16e-03 5.977e-04 4.275e-05 -2.431e-02 9.29e-03 -1.933e-02 1.161e-03 5.985e-04 -6.862e-05 -6.319e-04 9.29e-03 -1.933e-02 4.324e-05 -2.431e-02 -2.704e-03 -2.025e-02 -2.246e-03 -1.843e-02 -2.911e-03 -2.778e-02 -2.826e-03 -4.318e-02 1.4e-03 -3.143e-03 -8.192e-04 -4.174e-03 -1.983e-03 -3.723e-02 1.682e-02 -3.713e-02 -1.826e-05 -7.106e-04 1.22e-03 -2.896e-03 2.094e-03 -1.323e-03 7.676e-05 -1.415e-03 -3.543e-04 -2.349e-03 3.448e-04 -1.122e-03 6.417e-04 2.958e-04 -5.833e-04 -4.101e-03 -5.844e-04 -6.162e-03 1.23e-03 5.524e-04 3.448e-04 Page 13 1 6 5 4 1 5 1 6 5 5 1 5 1 4 1 6 1 3 4 3 4 6 1 4 2 5 1 6 1 4 1 6 1 4 2 4 2 5 1 2 4 5 1 6 2 5 1 5 1 1 5 5 Company Designer Job Number Model Name : : : : Centek Engineering FJP 21085.03 CTNH568A - Mount Jan 3, 2022 9:50 AM Checked By: TJL Envelope Joint Displacements (Continued) Joint 90 91 92 93 94 95 96 97 98 99 100 101 102 103 104 105 106 107 108 109 110 111 112 113 114 115 116 117 118 119 120 121 122 123 124 125 126 127 128 129 130 131 132 133 134 135 136 137 138 139 140 141 min N46 max min N47 max min N48 max min N49 max min N50 max min N51 max min N52 max min N53 max min N54 max min N55 max min N56 max min N57 max min N58 max min N59 max min N60 max min N61 max min N62 max min N63 max min N64 max min N65 max min N66 max min N67 max min N68 max min N69 max min N70 max min N71 max X [in] LC Y [in] LC Z [in] LC X Rotation [rad] -.038 .009 -.065 .214 -.031 .054 -.017 .253 -.061 0 -.004 2.489 -1.108 .222 -.377 2.14 -.632 .152 -.383 2.221 -.139 .059 -.541 2.581 .136 0 -.534 2.864 .171 -.06 -.379 1.927 .211 -.046 -.405 1.311 .259 -.053 -.338 1.915 .194 -.053 -.431 .141 .004 .034 0 .042 -.012 .069 .01 .123 5 2 4 1 5 4 2 1 4 6 1 1 4 5 1 1 4 4 1 1 4 5 1 1 6 4 1 1 6 6 1 1 6 6 2 1 3 3 4 4 3 3 4 2 6 1 6 2 5 4 3 2 -.039 .01 -.039 .014 -.024 .014 -.024 0 -.025 0 -.024 0 -.058 0 -.057 .022 -.034 .022 -.034 .019 -.013 .019 -.013 -.017 -.029 -.017 -.028 -.013 -.067 -.013 -.066 -.03 -.047 -.03 -.047 -.018 -.03 -.017 -.03 0 -.025 0 -.025 -.013 -.066 -.03 -.047 -.017 -.03 0 -.025 0 3 5 3 5 1 5 1 2 6 2 6 2 6 2 6 2 6 2 6 2 6 2 4 5 1 5 1 2 6 2 6 2 4 2 4 3 4 3 4 5 3 5 3 2 6 2 4 3 4 5 3 2 -.169 .058 -.467 1.763 -.991 .247 -.436 1.567 -1.845 .372 -.43 .924 -.996 .277 -.093 .523 -.937 .354 -.087 .253 -.981 .282 -.012 .049 -1.106 .362 .009 1.278 .265 .002 -.283 .933 .203 -.036 -.222 .977 .123 -.043 -.233 1.388 .073 -.036 -.226 .043 .008 .04 -.027 .033 -.022 .08 -.017 .037 1 2 4 4 1 1 4 4 1 1 4 4 1 2 4 4 1 1 5 5 1 1 4 5 1 1 5 1 6 6 2 1 3 6 1 4 3 3 1 4 3 3 4 5 3 4 2 4 2 4 2 5 -2.602e-03 1.837e-02 -2.524e-03 2.805e-02 -1.56e-02 1.651e-02 -9.12e-03 2.387e-02 -2.675e-02 1.787e-02 -1.58e-02 1.534e-02 -1.76e-02 4.672e-03 -1.049e-02 7.023e-03 -1.738e-02 3.749e-03 -1.217e-02 2.872e-03 -1.796e-02 1.16e-03 -8.737e-03 2.447e-04 -1.713e-02 3.339e-04 -1.378e-02 2.015e-02 4.687e-03 1.175e-02 4.863e-04 1.691e-02 2.986e-03 7.224e-03 1.866e-03 1.381e-02 2.231e-03 9.015e-03 1.467e-03 1.946e-02 1.201e-03 1.131e-02 1.242e-03 1.178e-02 7.599e-04 7.225e-03 1.897e-03 9.199e-03 1.467e-03 1.131e-02 1.242e-03 5.541e-03 RISA-3D Version 17.0.0 LC Y Rotatio... LC 1 -9.774e-03 1 4 1.557e-05 2 2 -2.386e-03 5 4 -9.101e-04 6 1 -1.26e-02 1 4 7.863e-04 5 1 -9.682e-04 1 4 -6.121e-04 6 1 -1.557e-02 1 4 1.154e-03 5 1 -1.937e-03 1 5 9.102e-03 4 1 -1.775e-03 2 4 1.322e-03 4 2 -7.837e-04 1 5 1 5 1 5 1 4 1 4 1 5 1 1 3 2 6 1 6 1 6 4 3 4 3 4 3 4 3 2 6 1 6 4 3 4 3 4 [J:\...\...\...\...\...\...\Risa 3D\CTNH568A_AMA Rev1.R3D] 8.22e-03 4 1 4 2 4 3 2 5 1 3 2 6 1 4 1 4 1 4 2 6 1 4 3 4 6.76e-03 1 -1.492e-02 4 1.941e-04 2 -3.279e-03 4 3.445e-03 1 -2.627e-04 4 2.151e-03 2 2.807e-04 6 -1.398e-04 3 -1.522e-03 4 1.941e-04 2 -3.279e-03 4 1.322e-03 4 -1.996e-03 7.064e-04 -2.237e-03 6.794e-03 1.005e-03 1.593e-03 -7.712e-05 9.315e-03 1.839e-03 3.964e-03 1.385e-04 1.222e-02 -5.061e-03 3.445e-03 -2.627e-04 1.169e-02 -5.914e-03 2.151e-03 2.807e-04 7.141e-03 -1.098e-02 -1.398e-04 -1.522e-03 Z Rotation [rad] LC -1.318e-03 -1.708e-04 -2.349e-03 7.677e-05 -1.611e-03 2.094e-03 -1.139e-03 1.221e-03 -3.022e-03 -1.826e-05 -7.105e-04 1.696e-02 -4.278e-02 9.357e-03 -1.829e-02 1.098e-02 -3.266e-02 5.402e-03 -1.662e-02 2.851e-03 -3.383e-02 2.27e-03 -2.12e-02 -1.972e-03 -3.757e-02 -1.097e-04 -2.462e-02 -2.858e-03 -4.864e-02 -2.36e-03 -1.906e-02 -3.735e-03 -2.99e-02 -1.711e-03 -1.622e-02 -3.958e-03 -2.122e-02 -2.229e-03 -1.209e-02 -2.977e-03 -2.809e-02 -2.331e-03 -1.853e-02 -2.376e-03 -2.027e-02 -1.711e-03 -1.641e-02 -2.26e-03 -1.21e-02 -2.331e-03 -1.853e-02 9.377e-03 Page 14 1 2 4 5 1 4 2 4 2 6 1 4 1 5 1 4 1 4 1 4 1 5 1 6 1 4 1 6 1 6 1 6 1 6 2 3 4 3 4 3 4 3 4 6 1 6 2 3 4 3 4 5 Company Designer Job Number Model Name : : : : Centek Engineering FJP 21085.03 CTNH568A - Mount Jan 3, 2022 9:50 AM Checked By: TJL Envelope Joint Displacements (Continued) Joint 142 143 144 145 146 147 148 149 150 151 152 153 154 155 156 157 158 159 160 161 162 163 164 165 166 167 168 169 170 171 172 173 174 175 176 177 178 179 180 181 182 183 184 185 186 187 188 189 190 191 192 193 min N72 max min N73 max min N74 max min N75 max min N76 max min N77 max min N78 max min N79 max min N80 max min N81 max min N82 max min N83 max min N84 max min N85 max min N86 max min N87 max min N88 max min N89 max min N90 max min N91 max min N92 max min N93 max min N94 max min N95 max min N96 max min N97 max X [in] LC Y [in] LC Z [in] LC X Rotation [rad] -.031 .067 .001 .032 -.002 .131 .002 1.547 .093 1.103 .108 .764 .15 1.141 .112 1.334 -.641 1.24 -.329 1.289 -.06 1.545 .082 .015 -.002 .015 -.002 .147 .003 .125 -.035 .083 .01 .152 .004 .171 -.028 .171 -.029 1.586 .091 1.339 -.67 1.207 .107 1.586 .091 .021 -.019 .112 0 .043 5 2 6 2 5 2 4 1 6 1 6 1 3 4 3 1 4 1 4 1 4 1 6 2 5 1 5 2 6 2 5 4 3 2 6 1 5 1 5 1 6 1 4 4 3 1 6 2 4 2 4 4 -.057 .022 -.034 .019 -.013 -.017 -.028 -.013 -.067 -.03 -.047 -.018 -.03 0 -.025 0 -.058 .022 -.034 .019 -.013 -.017 -.029 .003 -.024 -.013 -.061 -.018 -.029 .003 -.054 .001 -.025 -.014 -.063 .016 -.027 -.019 -.071 -.026 -.049 .014 -.057 .013 -.028 .003 -.074 .004 -.009 -.004 -.012 0 6 2 6 2 4 5 1 2 6 2 4 3 4 5 3 2 6 2 6 2 6 5 1 2 6 5 3 5 1 2 6 5 3 2 6 2 6 5 3 5 1 2 6 5 1 2 6 2 6 2 4 5 -.006 .026 .003 .046 .004 .018 -.01 .722 .13 .466 .099 .597 .061 .851 .04 .511 -.51 .331 -.458 .175 -.486 .043 -.634 .058 -.064 .143 0 .017 -.02 .04 -.008 .088 -.018 .042 .009 .899 -1.187 1.603 .072 .024 -.657 .528 -.513 .889 .037 .745 .129 .032 -.034 .002 0 .074 2 2 6 2 6 5 2 1 6 1 3 4 3 4 3 4 1 4 1 5 1 5 1 5 1 5 2 5 2 5 1 4 2 5 3 4 1 4 3 5 1 4 1 4 3 1 6 5 1 4 2 5 -1.052e-02 3.933e-03 -1.217e-02 1.343e-03 -8.738e-03 3.34e-04 -1.378e-02 2.01e-02 3.947e-03 1.69e-02 2.954e-03 1.362e-02 2.231e-03 1.932e-02 1.199e-03 1.326e-02 -1.755e-02 6.826e-03 -1.738e-02 2.676e-03 -1.796e-02 1.206e-04 -1.712e-02 1.782e-02 -1.576e-02 2.207e-02 5.456e-04 1.773e-04 -1.398e-02 5.59e-03 -1.053e-02 1.122e-02 1.359e-03 1.173e-02 4.226e-04 2.346e-02 -2.656e-02 4.541e-02 1.532e-03 2.113e-04 -1.676e-02 1.332e-02 -1.768e-02 1.946e-02 1.186e-03 1.985e-02 3.929e-03 5.745e-04 -2.094e-04 1.19e-03 5.061e-04 -2.957e-04 RISA-3D Version 17.0.0 LC Y Rotatio... LC 2 -7.837e-04 1 5 7.064e-04 4 1 -2.237e-03 2 4 1.593e-03 2 1 -7.712e-05 5 5 3.964e-03 2 1 1.385e-04 6 1 1.222e-02 1 6 -5.061e-03 4 1 1.169e-02 1 6 -5.914e-03 4 4 7.141e-03 1 3 -1.098e-02 4 4 3 5 1 5 1 5 1 4 1 4 1 4 3 5 1 4 2 4 3 2 6 4 1 4 3 4 1 5 1 4 3 1 6 3 2 6 5 5 [J:\...\...\...\...\...\...\Risa 3D\CTNH568A_AMA Rev1.R3D] 6.76e-03 1 -1.492e-02 4 9.102e-03 4 -1.775e-03 2 8.22e-03 4 1 4 3 1 3 4 2 3 4 3.88e-03 2 1.088e-04 6 1.184e-03 5 -5.636e-04 1 1.682e-04 2 -3.101e-03 4 3.188e-03 1 -2.63e-04 5 -6.477e-04 6 -1.607e-02 1 -1.806e-03 6 -9.567e-03 1 9.509e-03 1 1.876e-03 3 9.207e-03 4 -1.541e-03 2 7.032e-03 1 -1.536e-02 4 1.214e-02 1 -5.201e-03 4 1.292e-03 5 -1.952e-03 1 3.535e-03 2 1.335e-04 6 -8.708e-05 3 -1.996e-03 6.794e-03 1.005e-03 9.315e-03 1.839e-03 1.144e-03 -1.709e-03 -1.024e-04 -2.122e-03 Z Rotation [rad] LC -1.95e-02 5.403e-03 -1.68e-02 2.271e-03 -2.138e-02 -1.098e-04 -2.462e-02 -2.839e-03 -4.32e-02 -3.735e-03 -2.97e-02 -3.925e-03 -2.122e-02 -2.905e-03 -2.806e-02 1.692e-02 -3.735e-02 1.098e-02 -3.246e-02 2.851e-03 -3.363e-02 -1.968e-03 -3.722e-02 -1.117e-04 -6.154e-04 9.894e-04 5.444e-04 -2.104e-06 -2.44e-02 9.345e-03 -1.945e-02 -2.268e-03 -1.852e-02 -2.58e-03 -2.026e-02 1.389e-03 -3.151e-03 -8.11e-04 -4.163e-03 -1.978e-03 -3.723e-02 1.681e-02 -3.713e-02 -2.905e-03 -2.777e-02 -2.832e-03 -4.318e-02 1.622e-03 -1.684e-04 1.756e-04 -1.538e-03 7.67e-05 Page 15 1 4 1 5 1 4 1 6 1 6 1 3 4 3 4 4 1 4 1 4 1 6 1 5 1 6 2 4 1 5 1 3 4 6 1 4 2 5 1 6 1 4 1 3 4 6 1 6 2 2 6 5 Company Designer Job Number Model Name : : : : Centek Engineering FJP 21085.03 CTNH568A - Mount Jan 3, 2022 9:50 AM Checked By: TJL Envelope Joint Displacements (Continued) Joint 194 195 196 197 198 199 200 min max N98 min max N99 min N100 max min X [in] LC Y [in] LC Z [in] LC X Rotation [rad] .002 0 0 0 0 0 0 3 6 1 6 1 6 1 -.013 0 0 0 0 0 0 1 6 1 6 1 6 1 0 0 0 0 0 0 0 3 6 1 6 1 6 1 -1.798e-03 4.587e-04 2.728e-04 2.284e-03 -1.846e-04 1.171e-03 -1.113e-03 LC Y Rotatio... LC Z Rotation [rad] LC 3 -3.053e-03 4 -2.576e-04 3 4 2 5 3 5 1 0 0 0 0 0 0 6 1 6 1 6 1 -2.104e-05 -3.463e-03 -4.62e-04 -1.472e-03 8.351e-04 -7.465e-04 5 1 3 4 4 2 Envelope AISC 15th(360-16): LRFD Steel Code Checks 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 Memb... Shape PSA.4 PIPE_2.0 PSB.2 PIPE_2.0 M14A 6"x3/8" PSC.1 PIPE_2.0 PSC.4 PIPE_2.0 M13A 6"x3/8" PIPE_2.0 PIPE_2.0 PIPE_2.0 PIPE_2.0 PIPE_2.0 PIPE_2.0 M15 6"x3/8" M16 PIPE_2.0 M18 PIPE_2.0 M10 PIPE_3.0 PSC.3 PIPE_2.0 M14 PIPE_3.0 PSA.3 PIPE_2.0 M17 PIPE_2.0 M13 PIPE_3.0 M1 HSS4X4X4 M8 HSS4X4X4 M6 HSS4X4X4 M7 HSS4X4X4 M4 HSS4X4X4 M2 HSS4X4X4 M5 HSS4X4X4 M34 LL2x2x3x0 M3 HSS4X4X4 M36 LL2x2x3x0 M35 LL2x2x3x0 M9 HSS4X4X4 M33 L2.5x2.5x5 M32 L2.5x2.5x5 M31 L2.5x2.5x5 PSB.4 PSA.2 PSC.2 PSB.3 PSA.1 PSB.1 RISA-3D Version 17.0.0 Code Check .673 .636 .619 .600 .592 .551 .549 .500 .495 .469 .460 .458 .425 .387 .376 .370 .358 .335 .318 .311 .271 .215 .178 .177 .147 .142 .141 .134 .129 .127 .120 .095 .071 .017 .015 .009 L... 5.... 5.... .6... 5.... 5.... .6... 5.... 5.... 5.... 5.... 5.... 2.... .6... 1... 1... 7.... 5.... 4.... 5.... 4.... 7.... 0 2.... 2.... 1.... 0 2.... 2.... 0 2.... 4.... 4.... 2.... .8... .8... .8... LC 1 1 2 1 4 4 1 4 1 1 4 1 1 1 1 1 2 2 4 1 5 1 2 1 2 5 4 4 1 4 6 6 6 1 4 4 Sh...L... .280 4.5 .152 5.... .347 .6... .220 5.... .244 4.5 .372 .6... .142 4.5 .198 5.... .192 5.... .139 5.... .186 2.... .163 5.... .473 .6... .280 7.... .181 7.... .363 7.... .185 5.... .343 4.... .226 5.... .245 4.... .294 4.... .063 0 .206 0 .136 2.... .056 3.... .062 3.... .177 0 .178 0 .008 4.... .200 0 .009 4.... .004 4.... .149 0 .247 0 .264 0 .267 0 Dir ...phi*P... phi*Pn... 1 14.916 32.13 4 14.916 32.13 y 1 28.164 72.9 1 14.916 32.13 4 14.916 32.13 y 4 28.164 72.9 4 14.916 32.13 1 14.916 32.13 1 14.916 32.13 4 14.916 32.13 1 14.916 32.13 4 14.916 32.13 y 1 28.164 72.9 1 6.295 32.13 4 6.295 32.13 1 28.251 65.205 4 14.916 32.13 2 28.251 65.205 1 14.916 32.13 1 6.295 32.13 1 28.251 65.205 z 1 124.3...139.518 z 2 135.1...139.518 y 4 135.1...139.518 y 3 124.3...139.518 y 6 124.3...139.518 z 1 135.1...139.518 z 5 135.1...139.518 z 4 28.249 46.656 z 1 135.1...139.518 z 2 28.249 46.656 z 5 28.249 46.656 z 4 135.1...139.518 y 1 42.973 47.304 y 4 42.973 47.304 y 1 42.973 47.304 [J:\...\...\...\...\...\...\Risa 3D\CTNH568A_AMA Rev1.R3D] phi*Mn y-y [k-ft] 1.872 1.872 .57 1.872 1.872 .57 1.872 1.872 1.872 1.872 1.872 1.872 .57 1.872 1.872 5.749 1.872 5.749 1.872 1.872 5.749 16.181 16.181 16.181 16.181 16.181 16.181 16.181 2.147 16.181 2.147 2.147 16.181 1.316 1.316 1.316 phi*...Cb Eqn 1.872 4....H3... 1.872 2....H1... 9.113 1....H1... 1.872 1....H1... 1.872 3....H1... 9.113 1....H1... 1.872 3....H1... 1.872 3....H1... 1.872 2....H1... 1.872 2....H1... 1.872 3....H1... 1.872 1....H1... 9.113 1....H1... 1.872 3....H3... 1.872 4....H1... 5.749 1....H3... 1.872 2....H1... 5.749 1....H3... 1.872 2....H1... 1.872 3....H3... 5.749 1....H3... 16.... 1....H1... 16.... 1.5 H1... 16.... 1....H1... 16.... 1....H1... 16.... 1....H1... 16.... 1....H1... 16.... 1....H1... 1.607 1....H1... 16.... 1....H1... 1.607 1....H1... 1.607 1....H1... 16.... 1....H1... 3.061 1....H2... 3.061 1....H2... 3.061 1....H2... Page 16 Code Check ( Env ) Y Z No Calc > 1.0 .90-1.0 .75-.90 .50-.75 0.-.50 X N49 N51 N34 N47 N31 .02 N89 N36 N92 N79 N53 N45 .46 .67 N38 N55 .31 N43 N80 .38 N24 .32 N22 2 N19 .6 N13 N25 N83 N40 N35 .64 N86 N71 N65 N95 N63 .15 N61 N59 N77 .39 N48 .59 N6 N7 .14 N23 N97 .18 N46 .55 .50 .60 .22 . 13 N100 N70 N87 N8 N28 N20 N17 N11 N69 .37 N44 N56 N96 N68 N4 .12 N99 N2 N18 N41 N84 .14 N9 N1 N3 N26 .43 N21 N10 N39 .13 .34 .09 N12 .46 N78 N93 N5 N94 N75 N54 N73 .13 N74 N85 N32 N29 .36 .47 .27 N76 N30 N42 N90 N52 .01 N33 .55 .07 N14N50 .18 N72 N15 N37 N16 .01 N81 N82 N91 .50 N57 N27 N88 N67 N98 N66 N64 N58 N62 N60 Member Code Checks Displayed (Enveloped) Envelope Only Solution Centek Engineering FJP 21085.03 CTNH568A - Mount Unity Check Jan 3, 2022 at 9:51 AM CTNH568A_AMA Rev1.R3D LETTER OF AUTHORIZATION SITE NO/PROJECT NO: 208478/ 13704270 SITE NAME: Cheshire ADDRESS: 1325 CHESHIRE ST CHESHIRE, CT 06410-1849 APN: CHES-000038-000180 I, Margaret Robinson, Senior Counsel, US Tower Division on behalf of American Tower*, owner of the tower facility located at the address identified above (the “Tower Facility”), do hereby authorize Transcend Wireless its successors and assigns, to act as American Tower’s non-exclusive agent for the purpose of filing and securing any zoning, land-use, building permit and/or electrical permit application(s) and approvals of the applicable jurisdiction for and to conduct the construction of the installation of antennas and related telecommunications equipment on the Tower Facility located at the above address. This installation shall not affect adjoining lands and will occur only within the area leased by American Tower. American Tower understands that the application may be denied, modified or approved with conditions. The above authorization is limited to the acceptance by American Tower of conditions related to American Tower’s installation. Any such conditions of approval or modifications will not be effective unless approved in writing by American Tower. The above authorization does not permit Transcend Wireless to modify or alter any existing permit(s) and/or zoning or land-use conditions or impose any additional conditions unrelated to American Tower’s installation of telecommunications equipment without the prior written approval of American Tower. Signature: ____ Margaret Robinson, Senior Counsel US Tower Division NOTARY BLOCK COMMONWEALTH OF MASSACHUSETTS County of Middlesex This instrument was acknowledged before me by Margaret Robinson, Senior Counsel of American Tower (Tower Facility owner and/or operator), personally known to me (or proved to me on the basis of satisfactory evidence) to be the person whose name is subscribed to the within instrument and acknowledged to me that he/she executed the same. WITNESS my hand and official seal, this 29th day of September 2021. ٭American Tower as used herein is defined as American Tower Corporation and any of its affiliates or subsidiaries. EBI Consulting environmental | engineering | due diligence RADIO FREQUENCY EMISSIONS ANALYSIS REPORT EVALUATION OF HUMAN EXPOSURE POTENTIAL TO NON-IONIZING EMISSIONS T-Mobile Existing Facility Site ID: CTNH568A 1325 Cheshire Street Cheshire, Connecticut 06410 August 20, 2021 EBI Project Number: 6221004546 Site Compliance Summary Compliance Status: COMPLIANT Site total MPE% of FCC general population allowable limit: 22.35% 21 B Street, Burlington, MA 01803 . Tel: (781) 273.2500 . Fax: (781) 273.3311 EBI Consulting environmental | engineering | due diligence August 20, 2021 T-Mobile Attn: Jason Overbey, RF Manager 35 Griffin Road South Bloomfield, Connecticut 06002 Emissions Analysis for Site: CTNH568A EBI Consulting was directed to analyze the proposed T-Mobile facility located at 1325 Cheshire Street in Cheshire, Connecticut for the purpose of determining whether the emissions from the Proposed TMobile Antenna Installation located on this property are within specified federal limits. All information used in this report was analyzed as a percentage of current Maximum Permissible Exposure (% MPE) as listed in the FCC OET Bulletin 65 Edition 97-01and ANSI/IEEE Std C95.1. The FCC regulates Maximum Permissible Exposure in units of microwatts per square centimeter (µW/cm2). The number of µW/cm2 calculated at each sample point is called the power density. The exposure limit for power density varies depending upon the frequencies being utilized. Wireless Carriers and Paging Services use different frequency bands each with different exposure limits; therefore, it is necessary to report results and limits in terms of percent MPE rather than power density. All results were compared to the FCC (Federal Communications Commission) radio frequency exposure rules, 47 CFR 1.1307(b)(1) – (b)(3), to determine compliance with the Maximum Permissible Exposure (MPE) limits for General Population/Uncontrolled environments as defined below. General population/uncontrolled exposure limits apply to situations in which the general population may be exposed or in which persons who are exposed as a consequence of their employment may not be made fully aware of the potential for exposure or cannot exercise control over their exposure. Therefore, members of the general population would always be considered under this category when exposure is not employment related, for example, in the case of a telecommunications tower that exposes persons in a nearby residential area. Public exposure to radio frequencies is regulated and enforced in units of microwatts per square centimeter (μW/cm2). The general population exposure limits for the 600 MHz and 700 MHz frequency bands are approximately 400 μW/cm2 and 467 μW/cm2, respectively. The general population exposure limit for the 1900 MHz (PCS), 2100 MHz (AWS) and 11 GHz frequency bands is 1000 μW/cm2. Because each carrier will be using different frequency bands, and each frequency band has different exposure limits, it is necessary to report percent of MPE rather than power density. 21 B Street, Burlington, MA 01803 . Tel: (781) 273.2500 . Fax: (781) 273.3311 EBI Consulting environmental | engineering | due diligence Occupational/controlled exposure limits apply to situations in which persons are exposed as a consequence of their employment and in which those persons who are exposed have been made fully aware of the potential for exposure and can exercise control over their exposure. Occupational/controlled exposure limits also apply where exposure is of a transient nature as a result of incidental passage through a location where exposure levels may be above general population/uncontrolled limits (see below), as long as the exposed person has been made fully aware of the potential for exposure and can exercise control over his or her exposure by leaving the area or by some other appropriate means. Additional details can be found in FCC OET 65. CALCULATIONS Calculations were done for the proposed T-Mobile Wireless antenna facility located at 1325 Cheshire Street in Cheshire, Connecticut using the equipment information listed below. All calculations were performed per the specifications under FCC OET 65. Since T-Mobile is proposing highly focused directional panel antennas, which project most of the emitted energy out toward the horizon, all calculations were performed assuming a lobe representing the maximum gain of the antenna per the antenna manufacturer’s supplied specifications, minus 10 dB for directional panel antennas and 20 dB for highly focused parabolic microwave dishes, was focused at the base of the tower. For this report, the sample point is the top of a 6-foot person standing at the base of the tower. For power density calculations, the broadcast footprint of the AIR6449 antenna has been considered. Due to the beamforming nature of this antenna, the actual beam locations vary depending on demand and are narrow in nature. Using the broadcast footprint accounts for the potential location of beams at any given time. For all calculations, all equipment was calculated using the following assumptions: 1) 2 LTE channels (600 MHz Band) were considered for each sector of the proposed installation. These Channels have a transmit power of 30 Watts per Channel. 2) 1 NR channel (600 MHz Band) was considered for each sector of the proposed installation. This Channel has a transmit power of 80 Watts. 3) 2 LTE channels (700 MHz Band) were considered for each sector of the proposed installation. These Channels have a transmit power of 30 Watts per Channel. 4) 4 GSM channels (PCS Band - 1900 MHz) were considered for each sector of the proposed installation. These Channels have a transmit power of 30 Watts per Channel. 5) 2 LTE channels (PCS Band - 1900 MHz) were considered for each sector of the proposed installation. These Channels have a transmit power of 60 Watts per Channel. 21 B Street, Burlington, MA 01803 . Tel: (781) 273.2500 . Fax: (781) 273.3311 EBI Consulting environmental | engineering | due diligence 6) 2 UMTS channels (AWS Band - 2100 MHz) were considered for each sector of the proposed installation. These Channels have a transmit power of 30 Watts per Channel. 7) 2 LTE channels (AWS Band – 2100 MHz) were considered for each sector of the proposed installation. These Channels have a transmit power of 60 Watts per Channel. 8) 1 LTE Traffic channel (LTE 1C and 2C BRS Band - 2500 MHz) was considered for each sector of the proposed installation. This Channel has a transmit power of 60 Watts. 9) 1 LTE Broadcast channel (LTE 1C and 2C BRS Band - 2500 MHz) was considered for each sector of the proposed installation. This Channel has a transmit power of 20 Watts. 10) 1 NR Traffic channel (BRS Band - 2500 MHz) was considered for each sector of the proposed installation. This Channel has a transmit power of 120 Watts. 11) 1 NR Broadcast channel (BRS Band - 2500 MHz) was considered for each sector of the proposed installation. This Channel has a transmit power of 40 Watts. 12) All radios at the proposed installation were considered to be running at full power and were uncombined in their RF transmissions paths per carrier prescribed configuration. Per FCC OET Bulletin No. 65 - Edition 97-01 recommendations to achieve the maximum anticipated value at each sample point, all power levels emitting from the proposed antenna installation are increased by a factor of 2.56 to account for possible in-phase reflections from the surrounding environment. This is rarely the case, and if so, is never continuous. 13) For the following calculations, the sample point was the top of a 6-foot person standing at the base of the tower. The maximum gain of the antenna per the antenna manufacturer’s supplied specifications, minus 10 dB for directional panel antennas and 20 dB for highly focused parabolic microwave dishes, was used in this direction. This value is a very conservative estimate as gain reductions for these particular antennas are typically much higher in this direction. 14) The antennas used in this modeling are the RFS APXVAALL24_43-U-NA20 for the 600 MHz / 600 MHz / 700 MHz / 1900 MHz / 1900 MHz / 2100 MHz / 2100 MHz channel(s), the Ericsson AIR 6449 for the 2500 MHz / 2500 MHz / 2500 MHz / 2500 MHz channel(s) in Sector A, the RFS APXVAALL24_43-U-NA20 for the 600 MHz / 600 MHz / 700 MHz / 1900 MHz / 1900 MHz / 2100 MHz / 2100 MHz channel(s), the Ericsson AIR 6449 for the 2500 MHz / 2500 MHz / 2500 MHz / 2500 MHz channel(s) in Sector B, the RFS APXVAALL24_43-U-NA20 for the 600 MHz / 600 MHz / 700 MHz / 1900 MHz / 1900 MHz / 2100 MHz / 2100 MHz channel(s), the Ericsson AIR 6449 for the 2500 MHz / 2500 MHz / 2500 MHz / 2500 MHz channel(s) in Sector C. This is based on feedback from the carrier with regard to anticipated 21 B Street, Burlington, MA 01803 . Tel: (781) 273.2500 . Fax: (781) 273.3311 EBI Consulting environmental | engineering | due diligence antenna selection. All Antenna gain values and associated transmit power levels are shown in the Site Inventory and Power Data table below. The maximum gain of the antenna per the antenna manufacturer’s supplied specifications, minus 10 dB for directional panel antennas and 20 dB for highly focused parabolic microwave dishes, was used for all calculations. This value is a very conservative estimate as gain reductions for these particular antennas are typically much higher in this direction. 15) The antenna mounting height centerline of the proposed antennas is 129 feet above ground level (AGL). 16) Emissions values for additional carriers were taken from the Connecticut Siting Council active database. Values in this database are provided by the individual carriers themselves. 17) All calculations were done with respect to uncontrolled / general population threshold limits. 21 B Street, Burlington, MA 01803 . Tel: (781) 273.2500 . Fax: (781) 273.3311 EBI Consulting environmental | engineering | due diligence T-Mobile Site Inventory and Power Data Sector: Antenna #: Make / Model: Frequency Bands: Gain: Height (AGL): Channel Count: Total TX Power (W): ERP (W): Antenna A1 MPE %: Antenna #: A 1 RFS APXVAALL24_43U-NA20 600 MHz / 600 MHz / 700 MHz / 1900 MHz / 1900 MHz / 2100 MHz / 2100 MHz 12.95 dBd / 12.95 dBd / 13.65 dBd / 15.45 dBd / 15.45 dBd / 16.45 dBd / 16.45 dBd 129 feet 16 700 Watts 7.17% ERP (W): Antenna A2 MPE %: Frequency Bands: Gain: Height (AGL): Channel Count: Total TX Power (W): ERP (W): Antenna B1 MPE %: 2 Ericsson AIR 6449 2500 MHz / 2500 Frequency Bands: MHz / 2500 MHz / 2500 MHz 22.65 dBd / 17.3 dBd Gain: / 22.65 dBd / 17.3 dBd Height (AGL): 129 feet Channel Count: Make / Model: 22,096.08 Make / Model: Total TX Power (W): Sector: Antenna #: 4 240 Watts Antenna #: Sector: Antenna #: Make / Model: Frequency Bands: Gain: Height (AGL): 16 700 Watts Channel Count: Total TX Power (W): 22,096.08 7.17% ERP (W): Antenna C1 MPE %: 2 Antenna #: Make / Model: Ericsson AIR 6449 2500 MHz / 2500 Frequency Bands: MHz / 2500 MHz / 2500 MHz 22.65 dBd / 17.3 dBd Gain: / 22.65 dBd / 17.3 dBd Height (AGL): 129 feet Channel Count: Total TX Power (W): 36,356.09 8.64% B 1 RFS APXVAALL24_43U-NA20 600 MHz / 600 MHz / 700 MHz / 1900 MHz / 1900 MHz / 2100 MHz / 2100 MHz 12.95 dBd / 12.95 dBd / 13.65 dBd / 15.45 dBd / 15.45 dBd / 16.45 dBd / 16.45 dBd 129 feet ERP (W): Antenna B2 MPE %: 21 B Street, Burlington, MA 01803 . Tel: (781) 273.2500 16 700 Watts 22,096.08 7.17% 2 Ericsson AIR 6449 2500 MHz / 2500 Frequency Bands: MHz / 2500 MHz / 2500 MHz 22.65 dBd / 17.3 dBd Gain: / 22.65 dBd / 17.3 dBd Height (AGL): 129 feet Channel Count: Total TX Power (W): 36,356.09 8.64% 1 RFS APXVAALL24_43U-NA20 600 MHz / 600 MHz / 700 MHz / 1900 MHz / 1900 MHz / 2100 MHz / 2100 MHz 12.95 dBd / 12.95 dBd / 13.65 dBd / 15.45 dBd / 15.45 dBd / 16.45 dBd / 16.45 dBd 129 feet Make / Model: 4 240 Watts C ERP (W): Antenna C2 MPE %: . 4 240 Watts 36,356.09 8.64% Fax: (781) 273.3311 EBI Consulting environmental | engineering | due diligence Site Composite MPE % Carrier T-Mobile (Max at Sector A): AT&T T-Mobile MPE % Per Sector T-Mobile Sector A Total: 15.81% T-Mobile Sector B Total: 15.81% T-Mobile Sector C Total: 15.81% Site Total MPE % : 22.35% MPE % 15.81% 6.54% 22.35% Site Total MPE % : T-Mobile Maximum MPE Power Values (Sector A) T-Mobile Frequency Band / Technology (Sector A) # Channels Watts ERP (Per Channel) Height (feet) Total Power Density (µW/cm²) Frequency (MHz) Allowable MPE (µW/cm²) Calculated % MPE T-Mobile 600 MHz LTE 2 591.73 129.0 2.81 600 MHz LTE 400 0.70% T-Mobile 600 MHz NR 2 1577.94 129.0 7.50 600 MHz NR 400 1.87% T-Mobile 700 MHz LTE 2 695.22 129.0 3.30 700 MHz LTE 467 0.71% T-Mobile 1900 MHz GSM 4 1052.26 129.0 10.00 1900 MHz GSM 1000 1.00% T-Mobile 1900 MHz LTE 2 2104.51 129.0 10.00 1900 MHz LTE 1000 1.00% T-Mobile 2100 MHz UMTS 2 1324.71 129.0 6.30 2100 MHz UMTS 1000 0.63% T-Mobile 2100 MHz LTE 2 2649.42 129.0 12.59 2100 MHz LTE 1000 1.26% 1000 2.62% 1000 0.26% T-Mobile 2500 MHz LTE 1C & 2C Traffic T-Mobile 2500 MHz LTE 1C & 2C Broadcast T-Mobile 2500 MHz NR Traffic T-Mobile 2500 MHz NR Broadcast 2500 MHz LTE 1C & 2C Traffic 2500 MHz LTE 1C & 2C Broadcast 1 11044.63 129.0 26.25 1 1074.06 129.0 2.55 1 22089.26 129.0 52.49 2500 MHz NR Traffic 1000 5.25% 5.10 2500 MHz NR Broadcast 1000 0.51% Total: 15.81% 1 2148.13 129.0 • NOTE: Totals may vary by approximately 0.01% due to summation of remainders in calculations. 21 B Street, Burlington, MA 01803 . Tel: (781) 273.2500 . Fax: (781) 273.3311 EBI Consulting environmental | engineering | due diligence Summary All calculations performed for this analysis yielded results that were within the allowable limits for general population exposure to RF Emissions. The anticipated maximum composite contributions from the T-Mobile facility as well as the site composite emissions value with regards to compliance with FCC’s allowable limits for general population exposure to RF Emissions are shown here: T-Mobile Sector Sector A: Sector B: Sector C: T-Mobile Maximum MPE % (Sector A): Site Total: Site Compliance Status: Power Density Value (%) 15.81% 15.81% 15.81% 15.81% 22.35% COMPLIANT The anticipated composite MPE value for this site assuming all carriers present is 22.35% of the allowable FCC established general population limit sampled at the ground level. This is based upon values listed in the Connecticut Siting Council database for existing carrier emissions. FCC guidelines state that if a site is found to be out of compliance (over allowable thresholds), that carriers over a 5% contribution to the composite value will require measures to bring the site into compliance. For this facility, the composite values calculated were well within the allowable 100% threshold standard per the federal government. 21 B Street, Burlington, MA 01803 . Tel: (781) 273.2500 . Fax: (781) 273.3311 6/15/2021 RAN Template: 67E5A998E 6160 CTNH568A_Coverage Strategy_1_draft_2021-06-15 CTNH568A_Coverage Strategy_1_draft A&L Template: 67E5998E_1xAIR+1OP Print Name: Standard Section 1 - Site Information Site ID: CTNH568A Status: Draft Version: 1 Project Type: Coverage Strategy Approved: Not Approved Approved By: Not Approved Last Modified: 6/9/2021 1:44:46 PM Last Modified By: ANKIT.JAISWAL20@T-Mobile.com RAN Template: 67E5A998E 6160 Sector Count: 3 Antenna Count: 6 Site Name: CTNH568A Site Class: Monopole Site Type: Structure Non Building Plan Year: 2021 Market: CONNECTICUT CT Vendor: Ericsson Landlord: Not Specified DR Latitude: 41.53257000 Longitude: -72.87040000 Address: 1325 Cheshire St City, State: Cheshire, CT Region: NORTHEAST AL Template: 67E5998E_1xAIR+1OP AF Coax Line Count: 0 TMA Count: 0 RRU Count: 6 Section 2 - Existing Template Images T ----- This section is intentionally blank. ----- https://rfds-prod-web-core-secure.geo.cf.t-mobile.com/DataSheet/Printout/27b617fc-1fc9-4259-8549-3fd76db7426a?layoutId=17d88e19-1d4e-4d23-a… 1/8 6/15/2021 CTNH568A_Coverage Strategy_1_draft_2021-06-15 Section 3 - Proposed Template Images 67E5A998E.jpg DR AF T Notes: https://rfds-prod-web-core-secure.geo.cf.t-mobile.com/DataSheet/Printout/27b617fc-1fc9-4259-8549-3fd76db7426a?layoutId=17d88e19-1d4e-4d23-a… 2/8 6/15/2021 CTNH568A_Coverage Strategy_1_draft_2021-06-15 Section 4 - Siteplan Images DR ----- This section is intentionally blank. ----- AF T https://rfds-prod-web-core-secure.geo.cf.t-mobile.com/DataSheet/Printout/27b617fc-1fc9-4259-8549-3fd76db7426a?layoutId=17d88e19-1d4e-4d23-a… 3/8 6/15/2021 RAN Template: 67E5A998E 6160 CTNH568A_Coverage Strategy_1_draft_2021-06-15 CTNH568A_Coverage Strategy_1_draft A&L Template: 67E5998E_1xAIR+1OP Print Name: Standard DR Section 5 - RAN Equipment Existing RAN Equipment AF ----- This section is intentionally blank. ----Proposed RAN Equipment Template: 67E5A998E 6160 1 Enclosure Enclosure Type Baseband 2 Enclosure 6160 RBS 6601 BB 6648 BB 6648 BB 6648 DUW30 DUG20 L700 L2500 L2100 U2100 G1900 L600 N2500 L1900 T 3 B160 N600 Hybrid Cable System PSU 4813 Ericsson Hybrid Trunk 6/24 4AWG 100m (x 3 ) Transport System CSR IXRe V2 (Gen2) RAN Scope of Work: https://rfds-prod-web-core-secure.geo.cf.t-mobile.com/DataSheet/Printout/27b617fc-1fc9-4259-8549-3fd76db7426a?layoutId=17d88e19-1d4e-4d23-a… 4/8 6/15/2021 RAN Template: 67E5A998E 6160 CTNH568A_Coverage Strategy_1_draft_2021-06-15 CTNH568A_Coverage Strategy_1_draft A&L Template: 67E5998E_1xAIR+1OP Print Name: Standard DR Section 6 - A&L Equipment Existing Template: Custom Proposed Template: 67E5998E_1xAIR+1OP AF Sector 1 (Proposed) view from behind Coverage Type A - Outdoor Macro 1 Antenna Antenna Model RFS - APXVAALL24_43-U-NA20 (Octo) Azimuth T Ericsson - AIR6449 B41 (Active Antenna - Massive MIMO) 0/120/240 0/120/240 M. Tilt Height 135 P1 Ports Active Tech. 129' 135 L700 L600 2 P2 L700 L600 P3 129' P4 U2100 L2100 U2100 L2100 N600 N600 L1900 G1900 L1900 G1900 Coax Jumper (x2) Coax Jumper (x2) Coax Jumper (x2) P5 L2500 N2500 P6 L2500 N2500 Dark Tech. Restricted Tech. Decomm. Tech. E. Tilt Cables Coax Jumper (x2) TMAs Diplexers / Combiners Radio Radio 4480 B71+B85 (At Antenna) SHARED Radio 4480 B71+B85 (At Antenna) Radio 4460 B25+B66 (At Antenna) SHARED Radio 4460 B25+B66 (At Antenna) Sector Equipment Unconnected Equipment: Scope of Work: *A dashed border indicates shared equipment. Any connected equipment is denoted with the SHARED keyword. https://rfds-prod-web-core-secure.geo.cf.t-mobile.com/DataSheet/Printout/27b617fc-1fc9-4259-8549-3fd76db7426a?layoutId=17d88e19-1d4e-4d23-a… 5/8 6/15/2021 RAN Template: 67E5A998E 6160 CTNH568A_Coverage Strategy_1_draft_2021-06-15 CTNH568A_Coverage Strategy_1_draft A&L Template: 67E5998E_1xAIR+1OP Print Name: Standard Sector 2 (Proposed) view from behind Coverage Type A - Outdoor Macro 1 Antenna Antenna Model 2 RFS - APXVAALL24_43-U-NA20 (Octo) Ericsson - AIR6449 B41 (Active Antenna - Massive MIMO) 0/120/240 Azimuth 0/120/240 M. Tilt Height 135 135 P1 Ports Active Tech. 129' L700 L600 P2 L700 L600 P3 129' P4 U2100 L2100 U2100 L2100 N600 N600 L1900 G1900 L1900 G1900 Coax Jumper (x2) Coax Jumper (x2) Coax Jumper (x2) P5 L2500 N2500 P6 L2500 N2500 Dark Tech. Restricted Tech. Decomm. Tech. E. Tilt Cables Coax Jumper (x2) TMAs Diplexers / Combiners Radio Radio 4480 B71+B85 (At Antenna) SHARED Radio 4480 B71+B85 (At Antenna) Radio 4460 B25+B66 (At Antenna) SHARED Radio 4460 B25+B66 (At Antenna) Sector Equipment Unconnected Equipment: Scope of Work: *A dashed border indicates shared equipment. Any connected equipment is denoted with the SHARED keyword. https://rfds-prod-web-core-secure.geo.cf.t-mobile.com/DataSheet/Printout/27b617fc-1fc9-4259-8549-3fd76db7426a?layoutId=17d88e19-1d4e-4d23-a… 6/8 6/15/2021 RAN Template: 67E5A998E 6160 CTNH568A_Coverage Strategy_1_draft_2021-06-15 CTNH568A_Coverage Strategy_1_draft A&L Template: 67E5998E_1xAIR+1OP Print Name: Standard Sector 3 (Proposed) view from behind Coverage Type A - Outdoor Macro 1 Antenna Antenna Model Azimuth 2 RFS - APXVAALL24_43-U-NA20 (Octo) Ericsson - AIR6449 B41 (Active Antenna - Massive MIMO) 0/120/240 0/120/240 M. Tilt Height 135 135 P1 Ports Active Tech. 129' L700 L600 P2 L700 L600 P3 129' P4 U2100 L2100 U2100 L2100 N600 N600 L1900 G1900 L1900 G1900 Coax Jumper (x2) Coax Jumper (x2) Coax Jumper (x2) P5 L2500 N2500 P6 L2500 N2500 Dark Tech. Restricted Tech. Decomm. Tech. E. Tilt Cables Coax Jumper (x2) TMAs Diplexers / Combiners Radio Radio 4480 B71+B85 (At Antenna) SHARED Radio 4480 B71+B85 (At Antenna) Radio 4460 B25+B66 (At Antenna) SHARED Radio 4460 B25+B66 (At Antenna) Sector Equipment Unconnected Equipment: Scope of Work: *A dashed border indicates shared equipment. Any connected equipment is denoted with the SHARED keyword. https://rfds-prod-web-core-secure.geo.cf.t-mobile.com/DataSheet/Printout/27b617fc-1fc9-4259-8549-3fd76db7426a?layoutId=17d88e19-1d4e-4d23-a… 7/8 6/15/2021 RAN Template: 67E5A998E 6160 CTNH568A_Coverage Strategy_1_draft_2021-06-15 CTNH568A_Coverage Strategy_1_draft A&L Template: 67E5998E_1xAIR+1OP Print Name: Standard DR Section 7 - Power Systems Equipment Existing Power Systems Equipment AF ----- This section is intentionally blank. ----Proposed Power Systems Equipment 1 Enclosure Enclosure Type Enclosure 6160 T https://rfds-prod-web-core-secure.geo.cf.t-mobile.com/DataSheet/Printout/27b617fc-1fc9-4259-8549-3fd76db7426a?layoutId=17d88e19-1d4e-4d23-a… 8/8 Town of Cheshire, CT Property Listing Report Map Block Lot Building # 38180 1 Unique Identifier 00258300 Property Information Property Location 1325 CHESHIRE ST Mailing Address CHESHIRE CT 06410 Owner CHESHIRE TOWN OF Co-Owner SEWER FILTRATION PLANT Book / Page 0150/0376 Land Use Light Industrial Land Class Industrial Zoning Code R-40 Census Tract 3431 Neighborhood I-1B Acreage 59 Valuation Summary Utility Information (Assessed value = 70% of Appraised Value) Item Appraised Assessed Electric No Gas No Sewer No Buildings 4106621 2874630 Outbuildings 19282346 13497640 Land 1914679 1340280 Public Water No Total 25303646 17712550 Well No Primary Construction Details Heating Fuel Oil Building Use Light Industrial Year Built 1971 Heating Type FHA Building Condition Good Building Desc. Commercial AC Type Central Frame Type Excellent Bedrooms 0 Fireplaces 0 0 Building Style Stories 1.00 Full Bathrooms 0 Bsmt Gar Exterior Walls B. V. Solid Half Bathrooms 0 Fin Bsmt Area Exterior Walls 2 Extra Fixtures 0 Fin Bsmt Quality Interior Walls Total Rooms 0 Building Grade 0 Interior Walls 2 Bath Style NA Roof Style Flat Roof Cover Composite Built Up Interior Floors 1 Interior Floors 2 Composite Kitchen Style Occupancy 0 Report Created On 9/23/2021 Town of Cheshire, CT Property Listing Report Map Block Lot Building # 38180 Unique Identifier 1 00258300 Detached Outbuildings Type Description Area (sq ft) Condition Year Built Porch Open 880 Average 1991 Poles Light Fixtures 7 Average 1971 Lump Sum Lump Sum 0 Average 1971 Fencing Fencing 4000 Average 1971 Garage Concrete Block/Frame 720 Average 1994 Patio Concrete 200 Average 1971 Fencing Fencing 4000 Average 1971 Loading Dock Loading Dock 248 Average 1971 Shed Average Shed 316 Average 1995 Paving Paving 25000 Average 1971 Attached Extra Features Type Description Area (sq ft) Condition Year Built Sales History Owner of Record Book/ Page Sale Date Report Created On Sale Price 9/23/2021 Town of Cheshire, CT Property Listing Report Map Block Lot 38180 Building # 2 Unique Identifier 00258300 Primary Construction Details Heating Fuel Building Use Commercial Year Built 1971 Heating Type Building Condition Average Building Desc. Light Industrial AC Type Frame Type Excellent Building Style Bedrooms 0 Fireplaces 0 0 Stories 1.00 Full Bathrooms 0 Bsmt Gar Exterior Walls B. V. Solid Half Bathrooms 0 Fin Bsmt Area Exterior Walls 2 Extra Fixtures 0 Fin Bsmt Quality Interior Walls Total Rooms 0 Building Grade 0 Interior Walls 2 Bath Style NA Roof Style Flat Roof Cover Composite Built Up Interior Floors 1 Concrete Interior Floors 2 Kitchen Style Occupancy 0 Attached Extra Features Type Description Area (sq ft) Condition Report Created On Year Built 9/23/2021 Town of Cheshire, CT Property Listing Report Map Block Lot 38180 Building # 3 Unique Identifier 00258300 Primary Construction Details Heating Fuel Oil Building Use Commercial Year Built 1982 Heating Type FHA Building Condition Average Building Desc. Light Industrial AC Type Frame Type Excellent Building Style Bedrooms 0 Fireplaces 0 0 Stories 1.00 Full Bathrooms 0 Bsmt Gar Exterior Walls B. V. Solid Half Bathrooms 0 Fin Bsmt Area Exterior Walls 2 Extra Fixtures 0 Fin Bsmt Quality Interior Walls Total Rooms 0 Building Grade 0 Interior Walls 2 Bath Style NA Roof Style Flat Roof Cover Composite Built Up Interior Floors 1 Concrete Interior Floors 2 Kitchen Style Occupancy 0 Attached Extra Features Type Description Area (sq ft) Condition Report Created On Year Built 9/23/2021 Town of Cheshire, CT Property Listing Report Map Block Lot 38180 Building # 4 Unique Identifier 00258300 Primary Construction Details Heating Fuel Building Use Commercial Year Built 1971 Heating Type Building Condition Good Building Desc. Pump House AC Type Frame Type Excellent Building Style Bedrooms 0 Fireplaces 0 0 Stories 2.00 Full Bathrooms 0 Bsmt Gar Exterior Walls B. V. Solid Half Bathrooms 0 Fin Bsmt Area Exterior Walls 2 Extra Fixtures 0 Fin Bsmt Quality Interior Walls Total Rooms 0 Building Grade 0 Interior Walls 2 Bath Style NA Roof Style Flat Roof Cover Composite Built Up Interior Floors 1 Concrete Interior Floors 2 Kitchen Style Occupancy 0 Attached Extra Features Type Description Area (sq ft) Condition Report Created On Year Built 9/23/2021 Town of Cheshire, CT Property Listing Report Map Block Lot 38180 Building # 5 Unique Identifier 00258300 Primary Construction Details Heating Fuel Building Use Commercial Year Built 1990 Heating Type Building Condition Average Building Desc. Light Industrial AC Type Frame Type Excellent Building Style Bedrooms 0 Fireplaces 0 0 Stories 1.00 Full Bathrooms 0 Bsmt Gar Exterior Walls B. V. Solid Half Bathrooms 0 Fin Bsmt Area Exterior Walls 2 Extra Fixtures 0 Fin Bsmt Quality Interior Walls Total Rooms 0 Building Grade 0 Interior Walls 2 Bath Style NA Roof Style Flat Roof Cover Composite Built Up Interior Floors 1 Concrete Interior Floors 2 Kitchen Style Occupancy 0 Attached Extra Features Type Description Area (sq ft) Condition Report Created On Year Built 9/23/2021 Town of Cheshire, CT Property Listing Report Map Block Lot 38180 Building # 6 Unique Identifier 00258300 Primary Construction Details Heating Fuel Building Use Commercial Year Built 2006 Heating Type Building Condition Average Building Desc. Light Industrial AC Type Frame Type Excellent Building Style Bedrooms 0 Fireplaces 0 0 Stories 2.00 Full Bathrooms 0 Bsmt Gar Exterior Walls Concrete Block Half Bathrooms 0 Fin Bsmt Area Exterior Walls 2 Extra Fixtures 0 Fin Bsmt Quality Interior Walls Total Rooms 0 Building Grade Interior Walls 2 Bath Style NA Roof Style Interior Floors 1 Kitchen Style Interior Floors 2 Occupancy Roof Cover 0 Metal 0 Attached Extra Features Type Description Area (sq ft) Condition Report Created On Year Built 9/23/2021 Town of Cheshire, CT Property Listing Report Map Block Lot Building # 38180 7 Unique Identifier 00258300 Primary Construction Details Heating Fuel Oil Building Use Commercial Year Built 2014 Heating Type FHA Building Condition Average Building Desc. Pump House AC Type Central Frame Type Good Bedrooms 0 Fireplaces 0 0 Building Style Stories 0.00 Full Bathrooms 0 Bsmt Gar Exterior Walls Concrete Block Half Bathrooms 0 Fin Bsmt Area Exterior Walls 2 Extra Fixtures 0 Fin Bsmt Quality Interior Walls Total Rooms 0 Building Grade Interior Walls 2 Bath Style NA Roof Style Interior Floors 1 Kitchen Style Interior Floors 2 Occupancy Roof Cover 0 Metal 0 Attached Extra Features Type Description Canopy Metal Area (sq ft) 774 Condition Very Good Report Created On Year Built 1971 9/23/2021 Town of Cheshire, CT Property Listing Report Map Block Lot 38180 Building # 8 Unique Identifier 00258300 Primary Construction Details Heating Fuel Oil Building Use Commercial Year Built 2014 Heating Type FHA Building Condition Average Building Desc. Office Building AC Type Central Frame Type Good Bedrooms 0 Fireplaces 0 0 Building Style Stories 0.00 Full Bathrooms 0 Bsmt Gar Exterior Walls B. V. Solid Half Bathrooms 0 Fin Bsmt Area Exterior Walls 2 Extra Fixtures 0 Fin Bsmt Quality Interior Walls Total Rooms 0 Building Grade Interior Walls 2 Bath Style NA Roof Style Interior Floors 1 Kitchen Style Interior Floors 2 Occupancy 0 Roof Cover 0 Attached Extra Features Type Description Area (sq ft) Condition Report Created On Year Built 9/23/2021 Town of Cheshire, CT Property Listing Report Map Block Lot 38180 Building # 9 Unique Identifier 00258300 Primary Construction Details Heating Fuel Oil Building Use Commercial Year Built 2014 Heating Type FHA Building Condition Good Building Desc. Pump House AC Type Central Frame Type Very Good Bedrooms 0 Fireplaces 0 0 Building Style Stories 0.00 Full Bathrooms 0 Bsmt Gar Exterior Walls Concrete Block Half Bathrooms 0 Fin Bsmt Area Exterior Walls 2 Extra Fixtures 0 Fin Bsmt Quality Interior Walls Total Rooms 0 Building Grade Interior Walls 2 Bath Style NA Roof Style Interior Floors 1 Kitchen Style Interior Floors 2 Occupancy Roof Cover 0 Metal 0 Attached Extra Features Type Description Area (sq ft) Condition Report Created On Year Built 9/23/2021 Town of Cheshire, Connecticut - Assessment Parcel Map .1 3 325.46 202.41 100.63 202.41 111 #5 1.12 Ac 141 # 1369 1.06 Ac 228 .70 259 .82 112 #7 1.26 Ac 202.41 R CA R IA GE U HO Y WA SE 27 7 295.92 22 # 1344 1.3 Ac 381 21 9 4 # 1355 1.27 Ac .9 4 143 #5 1.09 Ac E ST 27 9 149 5 12 .5 1 3 10 .1 5 0 20 114 23.56 83 .9 4 24 # 1322 0.94 Ac 5 17 3 # 1339 0.92 Ac 5 10 3 IR 0 11 49 .7 SH 0 20 6 91 70 23 # 1338 0.32 Ac IDGE DR 200 85 S H M IT .6 1 PL 85 22 1 32 # 532 1.23 Ac 201 31 # 526 0.92 Ac 5 32 OA KR 0 20 10 1 224 1 28 E CH 40 # 540 5.75 Ac 290 41 # 1326 1.25 Ac 0 20 42 # 1320 1.55 Ac 2 30 118.51 60.0 9 114 # 11 1.64 Ac 82 .6 25 18 #1 135 113 #9 1.4 Ac .2 5 80 13 3 200 42 97 43 # 1314 1.68 Ac 32 194.51 200 6. 42 23 8. 19 4. 90.4 1 PL 300 5 #4 0.52 Ac 7 16 85 .61 100 .51 8 6 MA RK S 156 .70 130.9 290 .94 3 6 12 1 .3 .4 80 93 .4 14 5 10 1.4 201 .26 115 # 13 1.98 Ac 254 .07 130 # 499 1 Ac 176 297 .05 9 80.22 SA BL 90 .70 4 193 11 .4 296 .58 305 .13 17 # 1392 0.7 Ac 12 0 50 .7 129 # 495 1.17 Ac # 575 1.12 Ac 15 0.18 97.63 E CT 0 44 # 1308 1.12 Ac 131 # 503 1.14 Ac 40.87 94 .5 19 8 272.90 Location: 149 1325 CHESHIRE ST 166.80 120 Parcel: 00258300 23.56 148 # 1314 0.92 Ac 10 7 4 15 200 2 # 1311 0.36 Ac 9 12 490 29 5 .5 22 5 .0 7 29 5 .1 17 2 .5 46 20 0 6 15 5 25 9 6 64 .4 DE N 2 .4 22 8 15 3. 7 8 12 .0 8 69 # 11 0.96 Ac 58 5 208.51 7 20 .8 16 2.02 20 0 31.24 31 R ED S ID ER 20 0 1 87 .1 640 .4 4 4 17 6 # 540 0.92 Ac 9 # 660 1.13 Ac 7 # 620 1.03 Ac 8 # 640 1.01 Ac .4 4 165 # 525 1.05 Ac 259.9 3 480 15 Feet 1 inch = 308 feet 22 9 18 1. 320 20 1 160 133 # 453 Scale: 0.94 Ac 166 # 545 1.14 Ac RD RD 0 132 # 449 Approximate 0.92 Ac 22 0 20 1 IL L EH L HIL 200 151 # 457 0.92 Ac 20 0 X FO 229 .32 152 # 475 1.01 Ac 18 0 20 0 19 5 RIV 55 U IR 20 0 351 300 229.4 4 20 0 78 3 Ac 5 # 530 0.94 Ac 182 145.2 7 22 0 168 # 490 1.08 Ac SQ 172 0.22 Ac 20 0 227 171 # 450 2.03 Ac 23 0 265 170 # 454 1.1 Ac 19 0 NO B HILL RD 173 # 210 1.1 Ac 169 # 470 0.97 Ac 26 5 0 20 60 5 131 # 195 3.88 Ac .2 230 27 0 174 # 226 3.27 Ac 167 # 510 1.67 Ac 50 181 # 520 1.8 Ac 62 0 34 0.1 21 3 72 #5 0.92 Ac .7 2 71 #7 1.1 Ac 332.05 175 # 240 2.67 Ac 7 119 .11 30.57 70 #9 1.26 Ac .2 64 8 10 7 328 4 .3 6 216.69 30 5 44 0 11 6 33 .0 .1 .9 4 65 0 23 84.85 22 5 128 .08 CIR 74 #6 0.92 Ac 75 # 10 0.93 Ac W OR 4 177 # 270 1.83 Ac 15 5 22 3 .9 8 .5 68 # 13 1.02 Ac 150 176 # 256 2.02 Ac 6 14 0 76 # 20 0.92 Ac .5 19 1 13 6 77 # 30 0.92 Ac 17 5 25 9 3 .4 18 1 .1 5 .5 3 .8 5 20 6 8 15 5 .1 20 6 67 # 15 0.92 Ac 27 0 1 # 1301 0.2 Ac 3 13 66 # 17 0.92 Ac 20 0 119 .29 73 8 20 0 180 # 1325 59 Ac 39 # 91 1.58 Ac 142 # 19 0.94 Ac .5 12 0 6 22 33 # 94 1.68 Ac 182 # 555 1.89 Ac QU 15 # 550 INN IP IA C CT 14 0.92 Ac Map Produced: July 2021# 625 0.94 Ac Disclaimer: This map is for informational purposes only All information is subject to verification by any user. The Town of Cheshire and its mapping contractors assume no legal responsibility for the information contained herein. 3