GRUNDFOS DATA BOOKLET
S pumps, range 62
40 to 59 kW
60 Hz
S pumps, range 62
Table of contents
1.
Introduction
4
Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Applications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Main constructional features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
2.
Performance range
5
Performance range overview, S pumps. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Performance range, S pumps, range 62 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
List of pump curves . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
3.
4.
Identification
7
Type key . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Pump nameplate . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Ex approval plates . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Cable entry approval plate . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
7
7
8
8
Selection of product
9
Ordering the product . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
5.
Product range
10
Standard pumps - cast iron, 3 x 380/660 V . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Explosion-proof pumps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
6.
Variants
18
List of variants . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
7.
Construction
19
Sectional drawings, motors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
Components and material specification . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
8.
9.
Product description
27
Features. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Operating conditions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Motor range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Explosion-proof pumps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Level controllers. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Wiring diagrams . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
27
28
29
29
29
34
Curve charts and technical data
36
How to read the curve charts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Curve conditions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Pump performance testing. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Performance-test types for end-suction pumps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Specifying acceptance grades . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Certificates . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Witness test . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
36
37
37
38
40
41
41
10. Performance curves and technical data
Low pressure - 3 x 380/660 V . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Low pressure - 3 x 460 V . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Medium pressure - 3 x 380/660 V . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Medium pressure - 3 x 460 V. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
High pressure - 3 x 380/660 V . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
High pressure - 3 x 380/660 V . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
High pressure - 3 x 460 V . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
11. Accessories
42
42
46
50
54
58
60
62
66
Accessories (for installation) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 66
Other accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 68
12. Dimensions
Recommendation for pump foundations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Basic pump . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Installation on auto-coupling system . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Dry, vertical installation on base stand . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2
69
69
70
72
75
S pumps, range 62
13. Weights
77
14. Flange forces
78
15. Grundfos Product Center
79
Table of contents
Dry, horizontal installation on base stand . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 76
3
1
S pumps, range 62
Introduction
Applications
This data booklet deals with Grundfos heavy-duty
sewage pumps, type S, range 62.
S pumps are designed for applications such as these:
• raw-water intake
• wastewater treatment plants
• municipal pumping stations
• public buildings
• blocks of flats
• industries
• garages
• underground car parks
• car-wash areas
• restaurants and hotels.
The pumps are suitable for both temporary and
permanent installation. The lifting bracket fitted on the
pumps facilitates easy transportation as well as
installation at the installation site.
TM07 0218 4517
Introduction
1. Introduction
Fig. 1
S pump, range 62
S pumps, range 62, are a range of free-flow channel
impeller pumps specifically designed for pumping
sewage and wastewater in a wide range of municipal,
private and industrial applications.
The pumps are made of resistant materials, such as
cast iron and stainless steel. These materials ensure a
proper operation.
The pumps are fitted with motors from 40 to 59 kW.
The motors are 4-pole motors, depending on the motor
size.
The free passage in the pumps is 80 to 100 mm.
The pumps are available for these types of installation:
• submerged installation on auto-coupling system
• submerged installation, free-standing
• dry installation, vertical
• dry installation, horizontal.
4
Main constructional features
• Leak-proof connection on auto coupling via the
Grundfos SmartSeal sealing system
• double mechanical shaft seal system for reliable
sealing between pumped liquid and motor
• watertight cable entry
• moisture switch for continuous monitoring of motor
housing and terminal box ensuring automatic cut-off
of power in case of ingress of liquid
• self-cleaning channel impeller with long vanes
reducing the risk of jamming or clogging
• SmartTrim system allowing easy adjustment of
impeller clearance and maintaining maximum pump
efficiency over pump lifetime
• motor in insulation class F (155 °C), enclosure class
IP68 with three thermal sensors in stator windings
• shaft seal condition monitoring via water-in-oil
sensor (optional)
• explosion-proof motors for applications involving
high risk of explosion
• three stainless steel versions for use in corrosive or
aggressive liquids:
– stainless steel impeller, cast iron pump and motor
housing
– stainless steel pump housing, flange and impeller,
cast iron motor housing made entirely of
corrosion-resistant stainless steel.
2
S pumps, range 62
Performance range
2. Performance range
Performance range overview, S pumps
+
>P@
+]
4>OV@
4>PñK@
TM03 9286 0515
5
2
S pumps, range 62
Performance range
Performance range, S pumps, range 62
H
[m]
70
S Pumps
60
Range 62
60 Hz
50
S1.80.125
40
S1.100.125
30
25
20
15
S2.100.200
10
8
6
0
20
40
60
80
100
120
140
160
180
200
220
240
260
280
300
320
Q [l/s]
0
100
200
300
400
500
600
700
800
900
1000
Q [m³/h]
TM04 2261 2208
5
List of pump curves
3 x 380/660 V
Pump type
S2.100.200.400/520.4.62L
S2.100.200.590.4.62L
S1.100.125.400/520.4.62M
S1.100.125.590.4.62M
S1.80.125.400/520.4.62H
S1.80.125.590.4.62H
6
3 x 460 V
Pressure range
Low
Medium
High
Curve chart on
page
42
44
50
52
58
60
Pump type
S2.100.200.400/520.4.62L
S2.100.200.590.4.62L
S1.100.125.400/520.4.62M
S1.100.125.590.4.62M
S1.80.125.400/520.4.62H
S1.80.125.590.4.62H
Pressure range
Low
Medium
High
Curve chart on
page
46
48
54
56
62
64
3. Identification
Type key
1
Please note that the pump type described in this
booklet is not necessarily available in all variants.
Example: S1.100.100.55.4.50M.S.205.G.N.D.511.Z
2
S
ST
1
2
3
V
100
100
55
2
4
6
8
10
12
50
54
58
62
66
70
S
H
M
L
E
F
S
C
D
H
205
G
Q
S
R
N
Ex
B
C
D
5
6
11
13
15
GPA
Z
Explanation
Grundfos sewage and wastewater
pump
Multi-channel impeller pump installed
in a column pipe
Single-channel impeller
Two-channel impeller
Three-channel impeller
SuperVortex impeller
Maximum solid size [mm]
Nominal diameter of pump outlet port
[mm]
Designation
1
Pump type
Impeller type
Pump passage
Pump outlet,
S-type
Pump outlet, STNominal diameter of column pipe [mm]
type
P2 = Code number from type
Power output [kW] 1
designation / 10
2-pole motor
4-pole motor
6-pole motor
Number of poles
8-pole motor
10-pole motor
12-pole motor
Range 50
Range 54
Range 58
Pump range
Range 62
Range 66
Range 70
Super-high
High
Medium
Pressure version
Low
Extra-low
Super-low
Submersible installation without
cooling jacket
Submersible installation with cooling
Installation type
jacket
Dry installation, vertical
Dry installation, horizontal
Impeller diameter
Impeller diameter [mm]
(mean)
Cast-iron impeller, pump housing and
stator housing
Stainless-steel impeller, DIN W.-Nr.
Material code for
1.4408
impeller, pump
housing and stator
Stainless-steel impeller and pump
housing
housing, DIN W.-Nr. 1.4408
Stainless-steel impeller, pump housing
and stator housing, DIN W.-Nr. 1.4408
Non-explosion-proof pump
Pump version
Pump with explosion-proof motor
Pump with built-in SM 113 2
Not in use
S pump without built-in SM 113
50 Hz
60 Hz
3 x 400 / 690 V, Y/D (50 Hz only)
3 x 460 V, Y/D (60 Hz only)
3 x 415 V, Y/D (50 Hz only)
3 x 380 / 660 V, Y/D (60 Hz only)
Pumps only for Australia
Custom-built products
Pump nameplate
2
23
3
12
4
13
14
5
15
6
16
7
17
8
18
19
9
20
10
21
11
Fig. 2
Pos.
22
TM06 0370 5313
Code
The power output (P2) indicated in the type key, which is used to
indicate the motor size, can deviate from the actual power output.
Please refer to the nameplate or the chapter Performance curves
and technical data for the exact power output.
PTC sensors are connected directly to IO 113 or other PTC relay.
Identification
3
S pumps, range 62
Pump nameplate
Description
1
Type designation
2
Product number
3
Serial number
4
Maximum head
5
Maximum installation depth
6
Number of phases
7
Voltage, delta connection
8
Voltage, star connection
9
Rated power input, P1
10
Cos φ, 1/1 load
11
Production code, year and week
12
Generation code
13
Maximum ambient temperature
14
Maximum flow rate
15
Enclosure class
16
Frequency
17
Rated speed
18
Current, delta connection
19
Current, star connection
20
Rated power output, P2
21
Insulation class
22
Net weight
23
Place of production
Sensor version
Frequency [Hz]
Voltage code and
connection
Customisation
7
3
S pumps, range 62
Ex b c IIB T3
Baseefa 09ATEX0020X
Ex db IIB T3 Gb
IECEx BAS09.0006X
Type
yyww/no
Warnings:
Do not open when energized.
Cable temperature may exceed 70ºC.
Cable gland size and installation:see
installation and operating instructions.
Tamb=-5°C–+40°C
II2G
Ex b c IIB T4
Baseefa 09ATEX0020X
Ex db IIB T4 Gb
IECEx BAS09.0006X
Type
yyww/no
Warnings:
Do not open when energized or when
explosive gas atmosphere is present.
Cable temperature may exceed 70°C.
Cable gland size and installation:see
installation and operation manual.
Tamb=-5°C–+40°C
98488084
Fig. 3
0344
Made in H-8000 Székesfehérvár, Hungary
0344
98488082
Approval plate of explosion-proof pumps, T3 and
T4 classification
The approval plate gives the following details:
Pos.
Description
EU Ex symbol
ID no
Fig. 4
DK-8850
Cable entry approval plate
The approval plate gives the following details:
Pos.
CE
1180
Description
CE-mark
Number of quality assurance notified body
EU ex-symbol
II
Equipment group (II = non-mining)
2
Equipment category (high protection)
G
Type of explosive atmosphere
Ex
Explosion-proof motor according to European standard
b
Control of ignition sources
db
Flameproof
IIB
Gas group (Ethylene)
Tamb
Gb
Ambient temperature
Equipment protection level, zone 1
Baseefa Certificate number
II
Equipment group (II = non-mining)
2
Equipment category (high protection)
IECEx
Certificate number
G
Type of explosive atmosphere (G = Gas)
ID no
Inlet identification number (e.g. 36-1)
CE
0344
Ex
b
CE mark
Number of quality assurance notified body
Explosion-proof motor according to European standard
Control of ignition sources
c
Constructional safety
db
Flameproof enclosure
IIB
Gas group (Ethylene)
T3
Maximum surface temperature of the motor is 200 °C.
T4
Maximum surface temperature of the motor is 135 °C.
Gb
Equipment protection level, zone 1
Baseefa Certificate number
IECEx
8
Baseefa17ATEX0013U
0344
IECEx BAS 17.0007U
Ex db IIB Gb Tamb =-5°C–+80°C
TM06 7560 4617 - TM06 7561 4617
II2G
DK-8850 Bjerringbro, Denmark
Certificate number
TM06 7260 1217
Cable entry approval plate
II2G
DK-8850 Bjerringbro, Denmark
Made in H-8000 Székesfehérvár, Hungary
Identification
Ex approval plates
4. Selection of product
Ordering the product
Accessories
When ordering the product you need to take the
following four aspects into consideration:
1. pump
2. custom-built variation (option)
3. accessories
4. controller.
Depending on the installation type, you may need to
order accessories. See Accessories, page 66 for
selection of the correct accessories.
Note: Ordered accessories are not fitted from factory.
Pump
Use Product range starting on page 10 and Type key,
page 7 to identify the pump that best fulfils your needs.
The list below is a detailed description of the product
you get if you order the following pump:
Pump
S1.100.125.400.4.62M.S.292.G.N.D
Selection of product
4
S pumps, range 62
Controller
Grundfos Dedicated Controls (DC) is available.
For more information about Grundfos Dedicated
Controls, see Level controllers page 29.
Product no
96783474
• Pump as specified in the type key
• 10 m cable
• Paint: black, NCS 9000N/RAL 9005, gloss 30,
thickness 150 µm
• Three thermal switches (Klixon) or three thermal
sensors (PTC) in stator windings
• One moisture switch below the motor top cover (two
moisture switches in explosion-proof versions; one
below the motor top cover and one in the stator
housing in the bottom of the motor)
• Test according to ISO 9906:2012, grade 3B.
See Performance curves and technical data, page 42
for selection of a standard pump.
Note: Product specific data for the pump can also be
found in Grundfos Product Center using the product
number 96783474.
Custom-built variants
The S pumps can be customised to meet individual
requirements. Many pump features and options are
available for customisation, e.g. explosion-proof
versions, various cable lengths or special materials.
Variants can be seen in List of variants, page 18. For
requirements or designs not included in the list,
contact Grundfos.
9
5
S pumps, range 62
Product range
5. Product range
Standard pumps - cast iron, 3 x 380/660 V
Accessories
Pump type
S1.80.125.400.4.62H.S.320.G.N.D...
S1.80.125.400.4.62H.C.320.G.N.D...
S1.80.125.400.4.62H.D.320.G.N.D...
S1.80.125.400.4.62H.H.320.G.N.D...
S1.80.125.520.4.62H.S.334.G.N.D...
S1.80.125.520.4.62H.C.334.G.N.D...
S1.80.125.520.4.62H.D.334.G.N.D...
S1.80.125.520.4.62H.H.334.G.N.D...
S1.80.125.590.4.62H.S.351.G.N.D...
S1.80.125.590.4.62H.C.351.G.N.D...
S1.80.125.590.4.62H.D.351.G.N.D...
S1.80.125.590.4.62H.H.351.G.N.D...
S1.100.125.400.4.62M.S.292.G.N.D...
S1.100.125.400.4.62M.C.292.G.N.D...
S1.100.125.400.4.62M.D.292.G.N.D...
S1.100.125.400.4.62M.H.292.G.N.D...
S1.100.125.520.4.62M.S.308.G.N.D...
S1.100.125.520.4.62M.C.308.G.N.D...
S1.100.125.520.4.62M.D.308.G.N.D...
S1.100.125.520.4.62M.H.308.G.N.D...
S1.100.125.590.4.62M.S.326.G.N.D...
S1.100.125.590.4.62M.C.326.G.N.D...
S1.100.125.590.4.62M.D.326.G.N.D...
S1.100.125.590.4.62M.H.326.G.N.D...
S2.100.200.400.4.62L.S.245.G.N.D...
S2.100.200.400.4.62L.C.245.G.N.D...
S2.100.200.400.4.62L.D.245.G.N.D...
S2.100.200.400.4.62L.H.245.G.N.D...
S2.100.200.520.4.62L.S.256.G.N.D...
S2.100.200.520.4.62L.C.256.G.N.D...
S2.100.200.520.4.62L.D.256.G.N.D...
S2.100.200.520.4.62L.H.256.G.N.D...
S2.100.200.590.4.62L.S.272.G.N.D...
S2.100.200.590.4.62L.C.272.G.N.D...
S2.100.200.590.4.62L.D.272.G.N.D...
S2.100.200.590.4.62L.H.272.G.N.D...
1
10
Cable length
[m]
Pump
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
96783451
96783472
96788016
96783473
96783477
96783478
96788020
96783479
97535341
97535343
97535345
97535347
96783474
96783475
96788018
96783476
96803209
96803211
96803213
96803215
97535279
97535311
97535313
97535315
96783480
96783481
96788022
96783482
96783483
96783484
96788024
96783485
97535325
97535327
97535329
97535331
Horizontal base
stand 1
96787496
96787496
96787496
96787497
96787497
96787497
96787498
96787498
96787498
To be ordered separately
Vertical base
stand
Auto-coupling
system
96308238
96308238
96308238
96094523
96094523
96094523
96094525
96094525
96094525
-
96782145
96782145
96782145
96782145
96782145
96782145
96782145
96782145
96782145
96782145
96782145
96782145
96641489
96641489
96641489
96641489
96641489
96641489
-
Pumps of installation type H include the standard horizontal stand. Pumps with material code G or Q include a painted-steel stand. If another
horizontal stand is required, order a pump of installation type D together with the required stand.
Cast iron, 3 x 460 V
Accessories
Pump type
S1.80.125.400.4.62H.S.320.G.N.D...
S1.80.125.400.4.62H.C.320.G.N.D...
S1.80.125.400.4.62H.D.320.G.N.D...
S1.80.125.400.4.62H.H.320.G.N.D...
S1.80.125.520.4.62H.S.334.G.N.D...
S1.80.125.520.4.62H.C.334.G.N.D...
S1.80.125.520.4.62H.D.334.G.N.D...
S1.80.125.520.4.62H.H.334.G.N.D...
S1.80.125.590.4.62H.S.351.G.N.D...
S1.80.125.590.4.62H.C.351.G.N.D...
S1.80.125.590.4.62H.D.351.G.N.D...
S1.80.125.590.4.62H.H.351.G.N.D...
S1.100.125.400.4.62M.S.292.G.N.D...
S1.100.125.400.4.62M.C.292.G.N.D...
S1.100.125.400.4.62M.D.292.G.N.D...
S1.100.125.400.4.62M.H.292.G.N.D...
S1.100.125.520.4.62M.S.308.G.N.D...
S1.100.125.520.4.62M.C.308.G.N.D...
S1.100.125.520.4.62M.D.308.G.N.D...
S1.100.125.520.4.62M.H.308.G.N.D...
S1.100.125.590.4.62M.S.326.G.N.D...
S1.100.125.590.4.62M.C.326.G.N.D...
S1.100.125.590.4.62M.D.326.G.N.D...
S1.100.125.590.4.62M.H.326.G.N.D...
S2.100.200.400.4.62L.S.245.G.N.D...
S2.100.200.400.4.62L.C.245.G.N.D...
S2.100.200.400.4.62L.D.245.G.N.D...
S2.100.200.400.4.62L.H.245.G.N.D...
S2.100.200.520.4.62L.S.256.G.N.D...
S2.100.200.520.4.62L.C.256.G.N.D...
S2.100.200.520.4.62L.D.256.G.N.D...
S2.100.200.520.4.62L.H.256.G.N.D...
S2.100.200.590.4.62L.S.272.G.N.D...
S2.100.200.590.4.62L.C.272.G.N.D...
S2.100.200.590.4.62L.D.272.G.N.D...
S2.100.200.590.4.62L.H.272.G.N.D...
1
Cable length
[m]
Pump
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
95113302
95113303
96788015
95113304
95113308
95113309
96788019
95113310
97535340
97535342
97535344
97535346
95113305
95113306
96788017
95113307
96803208
96803210
96803212
96803214
97535278
97535280
97535312
97535314
95113311
95113312
96788021
95113313
95113314
95113315
96788023
95113316
97535324
97535326
97535328
97535330
Horizontal base
stand 1
96787496
96787496
96787496
96787497
96787497
96787497
96787498
96787498
96787498
To be ordered separately
Vertical base
stand
Auto-coupling
system
96308238
96308238
96308238
96094523
96094523
96094523
96094525
96094525
96094525
-
96782145
96782145
96782145
96782145
96782145
96782145
96782145
96782145
96782145
96782145
96782145
96782145
96641489
96641489
96641489
96641489
96641489
96641489
-
Product range
5
S pumps, range 62
Pumps of installation type H include the standard horizontal stand. Pumps with material code G or Q include a painted-steel stand. If another
horizontal stand is required, order a pump of installation type D together with the required stand.
11
5
S pumps, range 62
Product range
Stainless steel, 3 x 380/660 V
Accessories
Pump type
S1.80.125.400.4.62H.S.320.Q.N.D...
S1.80.125.400.4.62H.C.320.Q.N.D...
S1.80.125.400.4.62H.D.320.Q.N.D...
S1.80.125.400.4.62H.H.320.Q.N.D...
S1.80.125.520.4.62H.S.334.Q.N.D...
S1.80.125.520.4.62H.C.334.Q.N.D...
S1.80.125.520.4.62H.D.334.Q.N.D...
S1.80.125.520.4.62H.H.334.Q.N.D...
S1.80.125.590.4.62H.S.351.Q.N.D...
S1.80.125.590.4.62H.C.351.Q.N.D...
S1.80.125.590.4.62H.D.351.Q.N.D...
S1.80.125.590.4.62H.H.351.Q.N.D...
S1.100.125.400.4.62M.S.292.Q.N.D...
S1.100.125.400.4.62M.C.292.Q.N.D...
S1.100.125.400.4.62M.D.292.Q.N.D...
S1.100.125.400.4.62M.H.292.Q.N.D...
S1.100.125.520.4.62M.S.308.Q.N.D...
S1.100.125.520.4.62M.C.308.Q.N.D...
S1.100.125.520.4.62M.D.308.Q.N.D...
S1.100.125.520.4.62M.H.308.Q.N.D...
S1.100.125.590.4.62M.S.326.Q.N.D...
S1.100.125.590.4.62M.C.326.Q.N.D...
S1.100.125.590.4.62M.D.326.Q.N.D...
S1.100.125.590.4.62M.H.326.Q.N.D...
S2.100.200.400.4.62L.S.245.Q.N.D...
S2.100.200.400.4.62L.C.245.Q.N.D...
S2.100.200.400.4.62L.D.245.Q.N.D...
S2.100.200.400.4.62L.H.245.Q.N.D...
S2.100.200.520.4.62L.S.256.Q.N.D...
S2.100.200.520.4.62L.C.256.Q.N.D...
S2.100.200.520.4.62L.D.256.Q.N.D...
S2.100.200.520.4.62L.H.256.Q.N.D...
S2.100.200.590.4.62L.S.272.Q.N.D...
S2.100.200.590.4.62L.C.272.Q.N.D...
S2.100.200.590.4.62L.D.272.Q.N.D...
S2.100.200.590.4.62L.H.272.Q.N.D...
1
12
Cable length
[m]
Pump
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
97663035
97663037
97663039
97663141
97663151
97663153
97663155
97663157
97663199
97663201
97663203
99872032
97663143
97663145
97663147
97663149
97663175
97663177
97663179
97663181
97663183
97663185
97663187
97663189
97663159
97663161
97663163
97663165
97663167
97663169
97663171
97663173
97663191
97663193
97663195
97663197
Horizontal base
stand 1
96787496
96787496
96787496
96787497
96787497
96787497
96787498
96787498
96787498
To be ordered separately
Vertical base
stand
Auto-coupling
system
96308238
96308238
96308238
96094523
96094523
96094523
96094525
96094525
96094525
-
96782145
96782145
96782145
96782145
96782145
96782145
96782145
96782145
96782145
96782145
96782145
96782145
96641489
96641489
96641489
96641489
96641489
96641489
-
Pumps of installation type H include the standard horizontal stand. Pumps with material code G or Q include a painted-steel stand. If another
horizontal stand is required, order a pump of installation type D together with the required stand.
Stainless steel, 3 x 460 V
Accessories
Pump type
S1.80.125.400.4.62H.S.320.Q.N.D...
S1.80.125.400.4.62H.C.320.Q.N.D...
S1.80.125.400.4.62H.D.320.Q.N.D...
S1.80.125.400.4.62H.H.320.Q.N.D...
S1.80.125.520.4.62H.S.334.Q.N.D...
S1.80.125.520.4.62H.C.334.Q.N.D...
S1.80.125.520.4.62H.D.334.Q.N.D...
S1.80.125.520.4.62H.H.334.Q.N.D...
S1.80.125.590.4.62H.S.351.Q.N.D...
S1.80.125.590.4.62H.C.351.Q.N.D...
S1.80.125.590.4.62H.D.351.Q.N.D...
S1.80.125.590.4.62H.H.351.Q.N.D...
S1.100.125.400.4.62M.S.292.Q.N.D...
S1.100.125.400.4.62M.C.292.Q.N.D...
S1.100.125.400.4.62M.D.292.Q.N.D...
S1.100.125.400.4.62M.H.292.Q.N.D...
S1.100.125.520.4.62M.S.308.Q.N.D...
S1.100.125.520.4.62M.C.308.Q.N.D...
S1.100.125.520.4.62M.D.308.Q.N.D...
S1.100.125.520.4.62M.H.308.Q.N.D...
S1.100.125.590.4.62M.S.326.Q.N.D...
S1.100.125.590.4.62M.C.326.Q.N.D...
S1.100.125.590.4.62M.D.326.Q.N.D...
S1.100.125.590.4.62M.H.326.Q.N.D...
S2.100.200.400.4.62L.S.245.Q.N.D...
S2.100.200.400.4.62L.C.245.Q.N.D...
S2.100.200.400.4.62L.D.245.Q.N.D...
S2.100.200.400.4.62L.H.245.Q.N.D...
S2.100.200.520.4.62L.S.256.Q.N.D...
S2.100.200.520.4.62L.C.256.Q.N.D...
S2.100.200.520.4.62L.D.256.Q.N.D...
S2.100.200.520.4.62L.H.256.Q.N.D...
S2.100.200.590.4.62L.S.272.Q.N.D...
S2.100.200.590.4.62L.C.272.Q.N.D...
S2.100.200.590.4.62L.D.272.Q.N.D...
S2.100.200.590.4.62L.H.272.Q.N.D...
1
Cable length
[m]
Pump
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
97663034
97663036
97663038
97663040
97663150
97663152
97663154
97663156
97663198
97663200
97663202
99872025
97663142
97663144
97663146
97663148
97663174
97663176
97663178
97663180
97663182
97663184
97663186
97663188
97663158
97663160
97663162
97663164
97663166
97663168
97663170
97663172
97663190
97663192
97663194
97663196
Horizontal base
stand 1
96787496
96787496
96787496
96787497
96787497
96787497
96787498
96787498
96787498
To be ordered separately
Vertical base
stand
Auto-coupling
system
96308238
96308238
96308238
96094523
96094523
96094523
96094525
96094525
96094525
-
96782145
96782145
96782145
96782145
96782145
96782145
96782145
96782145
96782145
96782145
96782145
96782145
96641489
96641489
96641489
96641489
96641489
96641489
-
Product range
5
S pumps, range 62
Pumps of installation type H include the standard horizontal stand. Pumps with material code G or Q include a painted-steel stand. If another
horizontal stand is required, order a pump of installation type D together with the required stand.
13
5
S pumps, range 62
Product range
Explosion-proof pumps
Cast iron, 3 x 380/660 V
Accessories
Pump type
S1.80.125.400.4.62H.S.320.G.Ex.D...
S1.80.125.400.4.62H.C.320.G.Ex.D...
S1.80.125.400.4.62H.D.320.G.Ex.D...
S1.80.125.400.4.62H.H.320.G.Ex.D...
S1.80.125.520.4.62H.S.334.G.Ex.D...
S1.80.125.520.4.62H.C.334.G.Ex.D...
S1.80.125.520.4.62H.D.334.G.Ex.D...
S1.80.125.520.4.62H.H.334.G.Ex.D...
S1.80.125.590.4.62H.S.351.G.Ex.D...
S1.80.125.590.4.62H.C.351.G.Ex.D...
S1.80.125.590.4.62H.D.351.G.Ex.D...
S1.80.125.590.4.62H.H.351.G.Ex.D...
S1.100.125.400.4.62M.S.292.G.Ex.D...
S1.100.125.400.4.62M.C.292.G.Ex.D...
S1.100.125.400.4.62M.D.292.G.Ex.D...
S1.100.125.400.4.62M.H.292.G.Ex.D...
S1.100.125.520.4.62M.S.308.G.Ex.D...
S1.100.125.520.4.62M.C.308.G.Ex.D...
S1.100.125.520.4.62M.D.308.G.Ex.D...
S1.100.125.520.4.62M.H.308.G.Ex.D...
S1.100.125.590.4.62M.S.326.G.Ex.D...
S1.100.125.590.4.62M.C.326.G.Ex.D...
S1.100.125.590.4.62M.D.326.G.Ex.D...
S1.100.125.590.4.62M.H.326.G.Ex.D...
S2.100.200.400.4.62L.S.245.G.Ex.D...
S2.100.200.400.4.62L.C.245.G.Ex.D...
S2.100.200.400.4.62L.D.245.G.Ex.D...
S2.100.200.400.4.62L.H.245.G.Ex.D...
S2.100.200.520.4.62L.S.256.G.Ex.D...
S2.100.200.520.4.62L.C.256.G.Ex.D...
S2.100.200.520.4.62L.D.256.G.Ex.D...
S2.100.200.520.4.62L.H.256.G.Ex.D...
S2.100.200.590.4.62L.S.272.G.Ex.D...
S2.100.200.590.4.62L.C.272.G.Ex.D...
S2.100.200.590.4.62L.D.272.G.Ex.D...
S2.100.200.590.4.62L.H.272.G.Ex.D...
1
14
Cable length
[m]
Pump
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
96783486
96783487
96788026
96783488
96783492
96783493
96788030
96783494
97535349
97535351
97535353
97535355
96783489
96783490
96788028
96783491
96803217
96803219
96803221
96803223
97535317
97535319
97535321
97535323
96783495
96783496
96788032
96783497
96783498
96783500
96788034
96783501
97535333
97535335
97535337
97535339
Horizontal base
stand 1
96787496
96787496
96787496
96787497
96787497
96787497
96787498
96787498
96787498
To be ordered separately
Vertical base
stand
Auto-coupling
system
96308238
96308238
96308238
96094523
96094523
96094523
96094525
96094525
96094525
-
96782145
96782145
96782145
96782145
96782145
96782145
96782145
96782145
96782145
96782145
96782145
96782145
96641489
96641489
96641489
96641489
96641489
96641489
-
Pumps of installation type H include the standard horizontal stand. Pumps with material code G or Q include a painted-steel stand. If another
horizontal stand is required, order a pump of installation type D together with the required stand.
Cast iron, 3 x 460 V
Accessories
Pump type
S1.80.125.400.4.62H.S.320.G.Ex.D...
S1.80.125.400.4.62H.C.320.G.Ex.D...
S1.80.125.400.4.62H.D.320.G.Ex.D...
S1.80.125.400.4.62H.H.320.G.Ex.D...
S1.80.125.520.4.62H.S.334.G.Ex.D...
S1.80.125.520.4.62H.C.334.G.Ex.D...
S1.80.125.520.4.62H.D.334.G.Ex.D...
S1.80.125.520.4.62H.H.334.G.Ex.D...
S1.80.125.590.4.62H.S.351.G.Ex.D...
S1.80.125.590.4.62H.C.351.G.Ex.D...
S1.80.125.590.4.62H.D.351.G.Ex.D...
S1.80.125.590.4.62H.H.351.G.Ex.D...
S1.100.125.400.4.62M.S.292.G.Ex.D...
S1.100.125.400.4.62M.C.292.G.Ex.D...
S1.100.125.400.4.62M.D.292.G.Ex.D...
S1.100.125.400.4.62M.H.292.G.Ex.D...
S1.100.125.520.4.62M.S.308.G.Ex.D...
S1.100.125.520.4.62M.C.308.G.Ex.D...
S1.100.125.520.4.62M.D.308.G.Ex.D...
S1.100.125.520.4.62M.H.308.G.Ex.D...
S1.100.125.590.4.62M.S.326.G.Ex.D...
S1.100.125.590.4.62M.C.326.G.Ex.D...
S1.100.125.590.4.62M.D.326.G.Ex.D...
S1.100.125.590.4.62M.H.326.G.Ex.D...
S2.100.200.400.4.62L.S.245.G.Ex.D...
S2.100.200.400.4.62L.C.245.G.Ex.D...
S2.100.200.400.4.62L.D.245.G.Ex.D...
S2.100.200.400.4.62L.H.245.G.Ex.D...
S2.100.200.520.4.62L.S.256.G.Ex.D...
S2.100.200.520.4.62L.C.256.G.Ex.D...
S2.100.200.520.4.62L.D.256.G.Ex.D...
S2.100.200.520.4.62L.H.256.G.Ex.D...
S2.100.200.590.4.62L.S.272.G.Ex.D...
S2.100.200.590.4.62L.C.272.G.Ex.D...
S2.100.200.590.4.62L.D.272.G.Ex.D...
S2.100.200.590.4.62L.H.272.G.Ex.D...
1
Cable length
[m]
Pump
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
95113317
95113318
96788025
95113319
95113323
95113324
96788029
95113325
97535348
97535350
97535352
97535354
95113320
95113321
96788027
95113322
96803216
96803218
96803220
96803222
97535316
97535318
97535320
97535322
95113326
95113327
96788031
95113328
95113329
95113330
96788033
95113331
97535332
97535334
97535336
97535338
Horizontal base
stand 1
96787496
96787496
96787496
96787497
96787497
96787497
96787498
96787498
96787498
To be ordered separately
Vertical base
stand
Auto-coupling
system
96308238
96308238
96308238
96094523
96094523
96094523
96094525
96094525
96094525
-
96782145
96782145
96782145
96782145
96782145
96782145
96782145
96782145
96782145
96782145
96782145
96782145
96641489
96641489
96641489
96641489
96641489
96641489
-
Product range
5
S pumps, range 62
Pumps of installation type H include the standard horizontal stand. Pumps with material code G or Q include a painted-steel stand. If another
horizontal stand is required, order a pump of installation type D together with the required stand.
15
5
S pumps, range 62
Product range
Stainless steel impeller, 3 x 380/660 V
Accessories
Pump type
S1.80.125.400.4.62H.S.320.Q.Ex.D...
S1.80.125.400.4.62H.C.320.Q.Ex.D...
S1.80.125.400.4.62H.D.320.Q.Ex.D...
S1.80.125.400.4.62H.H.320.Q.Ex.D...
S1.80.125.520.4.62H.S.334.Q.Ex.D...
S1.80.125.520.4.62H.C.334.Q.Ex.D...
S1.80.125.520.4.62H.D.334.Q.Ex.D...
S1.80.125.520.4.62H.H.334.Q.Ex.D...
S1.80.125.590.4.62H.S.351.Q.Ex.D...
S1.80.125.590.4.62H.C.351.Q.Ex.D...
S1.80.125.590.4.62H.D.351.Q.Ex.D...
S1.80.125.590.4.62H.H.351.Q.Ex.D...
S1.100.125.400.4.62M.S.292.Q.Ex.D...
S1.100.125.400.4.62M.C.292.Q.Ex.D...
S1.100.125.400.4.62M.D.292.Q.Ex.D...
S1.100.125.400.4.62M.H.292.Q.Ex.D...
S1.100.125.520.4.62M.S.308.Q.Ex.D...
S1.100.125.520.4.62M.C.308.Q.Ex.D...
S1.100.125.520.4.62M.D.308.Q.Ex.D...
S1.100.125.520.4.62M.H.308.Q.Ex.D...
S1.100.125.590.4.62M.S.326.Q.Ex.D...
S1.100.125.590.4.62M.C.326.Q.Ex.D...
S1.100.125.590.4.62M.D.326.Q.Ex.D...
S1.100.125.590.4.62M.H.326.Q.Ex.D...
S2.100.200.400.4.62L.S.245.Q.Ex.D...
S2.100.200.400.4.62L.C.245.Q.Ex.D...
S2.100.200.400.4.62L.D.245.Q.Ex.D...
S2.100.200.400.4.62L.H.245.Q.Ex.D...
S2.100.200.520.4.62L.S.256.Q.Ex.D...
S2.100.200.520.4.62L.C.256.Q.Ex.D...
S2.100.200.520.4.62L.D.256.Q.Ex.D...
S2.100.200.520.4.62L.H.256.Q.Ex.D...
S2.100.200.590.4.62L.S.272.Q.Ex.D...
S2.100.200.590.4.62L.C.272.Q.Ex.D...
S2.100.200.590.4.62L.D.272.Q.Ex.D...
S2.100.200.590.4.62L.H.272.Q.Ex.D...
1
16
Cable length
[m]
Pump
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
97663207
97663209
97663211
97663213
97663223
97663225
97663227
97663229
97663271
97663273
97663275
97663277
97663215
97663217
97663219
97663221
97663247
97663249
97663251
97663253
97663255
97663257
97663259
97663261
97663231
97663233
97663235
97663237
97663239
97663241
97663243
97663245
97663263
97663265
97663267
97663269
Horizontal base
stand 1
96787496
96787496
96787496
96787497
96787497
96787497
96787498
96787498
96787498
To be ordered separately
Vertical base
stand
Auto-coupling
system
96308238
96308238
96308238
96094523
96094523
96094523
96094525
96094525
96094525
-
96782145
96782145
96782145
96782145
96782145
96782145
96782145
96782145
96782145
96782145
96782145
96782145
96641489
96641489
96641489
96641489
96641489
96641489
-
Pumps of installation type H include the standard horizontal stand. Pumps with material code G or Q include a painted-steel stand. If another
horizontal stand is required, order a pump of installation type D together with the required stand.
Stainless steel impeller, 3 x 460 V
Accessories
Pump type
S1.80.125.400.4.62H.S.320.Q.Ex.D...
S1.80.125.400.4.62H.C.320.Q.Ex.D...
S1.80.125.400.4.62H.D.320.Q.Ex.D...
S1.80.125.400.4.62H.H.320.Q.Ex.D...
S1.80.125.520.4.62H.S.334.Q.Ex.D...
S1.80.125.520.4.62H.C.334.Q.Ex.D...
S1.80.125.520.4.62H.D.334.Q.Ex.D...
S1.80.125.520.4.62H.H.334.Q.Ex.D...
S1.80.125.590.4.62H.S.351.Q.Ex.D...
S1.80.125.590.4.62H.C.351.Q.Ex.D...
S1.80.125.590.4.62H.D.351.Q.Ex.D...
S1.80.125.590.4.62H.H.351.Q.Ex.D...
S1.100.125.400.4.62M.S.292.Q.Ex.D...
S1.100.125.400.4.62M.C.292.Q.Ex.D...
S1.100.125.400.4.62M.D.292.Q.Ex.D...
S1.100.125.400.4.62M.H.292.Q.Ex.D...
S1.100.125.520.4.62M.S.308.Q.Ex.D...
S1.100.125.520.4.62M.C.308.Q.Ex.D...
S1.100.125.520.4.62M.D.308.Q.Ex.D...
S1.100.125.520.4.62M.H.308.Q.Ex.D...
S1.100.125.590.4.62M.S.326.Q.Ex.D...
S1.100.125.590.4.62M.C.326.Q.Ex.D...
S1.100.125.590.4.62M.D.326.Q.Ex.D...
S1.100.125.590.4.62M.H.326.Q.Ex.D...
S2.100.200.400.4.62L.S.245.Q.Ex.D...
S2.100.200.400.4.62L.C.245.Q.Ex.D...
S2.100.200.400.4.62L.D.245.Q.Ex.D...
S2.100.200.400.4.62L.H.245.Q.Ex.D...
S2.100.200.520.4.62L.S.256.Q.Ex.D...
S2.100.200.520.4.62L.C.256.Q.Ex.D...
S2.100.200.520.4.62L.D.256.Q.Ex.D...
S2.100.200.520.4.62L.H.256.Q.Ex.D...
S2.100.200.590.4.62L.S.272.Q.Ex.D...
S2.100.200.590.4.62L.C.272.Q.Ex.D...
S2.100.200.590.4.62L.D.272.Q.Ex.D...
S2.100.200.590.4.62L.H.272.Q.Ex.D...
1
Cable length
[m]
Pump
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
10
97663206
97663208
97663210
97663212
97663222
97663224
97663226
97663228
97663270
97663272
97663274
97663276
97663214
97663216
97663218
97663220
97663246
97663248
97663250
97663252
97663254
97663256
97663258
97663260
97663230
97663232
97663234
97663236
97663238
97663240
97663242
97663244
97663262
97663264
97663266
97663268
Horizontal base
stand 1
96787496
96787496
96787496
96787497
96787497
96787497
96787498
96787498
96787498
To be ordered separately
Vertical base
stand
Auto-coupling
system
96308238
96308238
96308238
96094523
96094523
96094523
96094525
96094525
96094525
-
96782145
96782145
96782145
96782145
96782145
96782145
96782145
96782145
96782145
96782145
96782145
96782145
96641489
96641489
96641489
96641489
96641489
96641489
-
Product range
5
S pumps, range 62
Pumps of installation type H include the standard horizontal stand. Pumps with material code G or Q include a painted-steel stand. If another
horizontal stand is required, order a pump of installation type D together with the required stand.
17
6
S pumps, range 62
Variants
6. Variants
List of variants
Motor
Various cable lengths
EMC power cables
Screened power cables for variable-speed drives
Special motor
15 m
25 m
50 m
10 m
15 m
25 m
50 m
Insulation class H
Special voltage
PTC thermistors in windings
Special oil
Non-toxic Shell Ondina X420 1
Motor protection
Pt100 on lower bearing + Pt100 on upper bearing + Pt100 on
windings
Pt100 on lower bearing + Pt100 on upper bearing + Pt100 on
windings + PVS3 vibration sensor
External water-in-oil sensor
Sensor set 2
Sensor set 3
WIO
Coating
Special paint thickness
Impeller (external surface)
Impeller (internal surface)
Pump housing (internal)
Inlet cover
Zinc anodes (outside of inlet cover / pump housing)
300 µm (painted twice)
450 µm (painted three times)
Epoxy coating (NCS 900N/RAL 9005 gloss 30,
black)
Belzona 1321 coating (brush painted, blue)
Chesterton ARC 855 ceramic coating (grey)
Epoxy coating (NCS 900N/RAL 9005 gloss 30,
black)
Belzona 1321 coating (brush painted, blue)
Chesterton ARC 855 ceramic coating (grey)
Epoxy coating (NCS 900N/RAL 9005 gloss 30,
black)
Belzona 1321 coating (brush painted, blue)
Chesterton ARC 855 ceramic coating (grey)
3 pcs.
Materials
Stainless steel lifting bracket
Stainless steel shaft
Impeller
AISI 316
AISI 329
Stainless steel
Tests
Test at specified duty on standard impeller curve
Trimmed impeller for specified duty test
Additional test of entire QH curve (including report)
5-10 points from pump performance curve
Different test standard
Efficiency guaranteed by Grundfos
Vibration test (including report)
Performance test on dry test stand
NPSHr test
String test
Witness test
According to Grundfos factory quality standard
Contact Grundfos
Contact Grundfos
Contact Grundfos
Contact Grundfos
Miscellaneous
Special packaging
Special nameplate
Other variants
1
18
For pumps with WIO sensor Shell Ondina is not an option.
Contact Grundfos
Contact Grundfos
Contact Grundfos
ISO 9906:2012 grade 1E
tolerances
ISO 9906:2012 grade 1B/1U
tolerances
ISO 9906:2012 grade 2B/2U
tolerances
7
S pumps, range 62
Construction
7. Construction
Sectional drawings, motors
D-D
E-E
176d 176c
B
193 194
173b 173
520
520a
176a
176b
A
A
25
100
178
B
248
252
250a
A-A
B-B
181
250
181a
250b
168
180
E
E
198
164a
D
D
190
157
177a
190b
61c
59b
154
150
157b
48
55
172
150c
60
182b
187
155
187a
72a
184
37a
72
153
193
194
58
109
271
105b
270
26a
77 105
Fig. 5
107
TM04 2306 0917
59
182a
Non-explosion-proof motor without cooling jacket (installation type S)
19
7
S pumps, range 62
Construction
176d
176c
E-E
B
173b 173
D-D
520
193
194
520a
176a
A
A
176b
25
100
178
B
A-A
B-B
248
252
250a
181a
181
250
168
250b
180
E
E
198
164a
D
D
190
157
177a
190b
59b
61c
154
48
150
55
172
60
182b
187
155
187a
72a
184
72
153
58
109
182a
271
270
105b
26a
77
Fig. 6
20
105
107
Non-explosion-proof motor without cooling jacket (installation types C, D and H)
TM04 2307 0917
59
7
Construction
S pumps, range 62
G-G
520
B
E-E
176d 176c
173f
173e
173d
D-D
193 194
173b 173
520
520a
176a
A
A
25
100
25a
176b
178
248 248a 252
B
A-A
181
B-B
181a
250
168
250a
180
250b
E
E
D
D
180a
198
164a
190
157
177a
190b
61c
59b
154
157b
150
48
55
172
150c
60
182b
187
155
187a
72a
184
G
G
72
153
193
194
58
109
37a
271
270
105b
77
Fig. 7
105
107
26a
TM04 2309 0917
59
182a
Explosion-proof motor with cooling jacket (installation type S)
21
7
S pumps, range 62
Construction
G-G
520
D-D
E-E
B
176c
173f
173e
173d
176d
173b 173
193 520
194 520a
H
H
176a
A
A
176b
25
100
25a
178
B
248 248a 252
B-B
A-A
250
181a
181
250a
168
250b
180
180a
E
E
198
164a
D
D
157
190
61c
177a
154
150
190b
59b
48
55
172
60
182b
187
155
187a
72a
184
G
G
72
153
58
109
271
182a
270
105b
26a
77 105
Fig. 8
22
107
Explosion-proof motor without cooling jacket (installation types C, D and H)
TM04 2308 0917
59
7
S pumps, range 62
TM04 2310 0917
Construction
Sectional drawings, pumps
Fig. 9
Basic pump, installation types S and C
23
7
S pumps, range 62
Construction
702
703
TM04 2315 2308
701
Fig. 10 Installation types S and C pump on auto coupling
24
7
TM04 2316 2308
Construction
S pumps, range 62
TM04 2313 2308
Fig. 11 Installation type D, dry vertical pump on base stand
Fig. 12 Installation type H, dry, horizontal installation on base stand
25
7
Construction
26
S pumps, range 62
Components and material specification
Motor
Pos.
Component
Material
DIN W.Nr./
EN
standard
AISI/
ASTM
Pos.
Component
Material
7a
Rivet
Stainless steel
1.4436
316
250
Cable clamp
PA or cast iron
25
Pressure test plug
Stainless steel
1.4436
316
250a
Cable entry
PA or cast iron
25a
Screw
Stainless steel
1.4436
316
250b
Rubber seal
26a
Screw
Stainless steel
1.4436
316
250e
Moisture switch
37a
O-ring
NBR rubber
48
Stator
55
Stator housing
Cast iron
58
Seal housing
Cast iron
59
Lower bearing bracket
cover
Cast iron
59b
Pin
Steel
60
Bearing bracket cover
Cast iron
61c
Upper bearing bracket
Cast iron
1
72
O-ring
NBR rubber
72a
O-ring
NBR rubber
76a
Approval plate
77
Seal housing cover
Cast iron
100
O-ring
NBR rubber
105
Mechanical seal
SiC/SiC or SiC/
carbon
EN-JL-1040
A48 30
1
2
3
252
Cable
270
Nut
271
Lock washer
520a
Screw
520
Moisture switch 3
DIN W.Nr./
EN
standard
AISI/
ASTM
1.4436
316
DIN W.Nr./
EN
standard
AISI/
ASTM
1.4436
316
1.4436
316
ATON
Stainless steel
Available in stainless steel (custom-built option).
Ex versions have cast iron cable entry.
Ex versions have three moisture switches.
Pump
Pos.
Component
Material
1
Intermediate ring
Cast iron
7a
Rivet
Stainless steel
7b
O-ring
NBR rubber
105b
Mechanical seal
SiC/SiC or SiC/
carbon
107
O-ring
NBR rubber
9a
Key (for keyway)
Stainless steel
109
O-ring
NBR rubber
12
Flange
Cast iron
Cast iron
150
Stator housing complete
12a
Inlet cover
150c
Cooling jacket
Galvanized steel
12c
Adjusting screw
Stainless steel
1.4436
316
153
Ball bearing
Stainless steel
26
Screw
Stainless steel
1.4436
316
154
Ball bearing
Stainless steel
26c
Screw
Stainless steel
155
Lower bearing bracket
Cast iron 1
35
Screw
Stainless steel
157
O-ring
NBR rubber
35a
Screw
Stainless steel
157b
O-ring
NBR rubber
37
O-ring
NBR rubber
164a
Motor top cover
Cast iron
37b
O-ring
NBR rubber
168
Cable entry
PA or cast iron 2
39
O-ring
NBR rubber
172
Shaft with rotor
Stainless steel
1.4462
329
39a
O-ring
NBR rubber
173
Screw
Stainless steel
1.4436
316
49
Impeller
Cast iron 1
EN-JL 1050
50
Volute casing
Cast iron1
EN-JL 1050
Cast iron or
stainless steel
173b
Earth terminal
173c
Washer
173d
Washer
Stainless steel
1.4436
316
173e
Screw
Stainless steel
1.4436
316
173f
Spring washer
Stainless steel
1.4436
316
173g
Earth connector
Stainless steel
1.4436
316
176a
Terminal block
176b
Screw
176c
Terminal block
176d
Terminal block
177a
Protection sleeve
178
Screw
Stainless steel
180
Cable clamp
PA or cast iron
180a
Screw
Stainless steel
181
Cable
ATON
181a
Screw
Stainless steel
182a
Screw
1.4436
316
1
66
Cap
66b
Washer
67
Impeller screw
76
Nameplate
Stainless steel
76a
Approval plate
301
Motor housing
487
Base stand, horizontal
494
Plug
Stainless steel
495
O-ring
NBR rubber
1.4436
316
1.4436
316
Cast iron or steel
Available in stainless steel (custom-built option).
Accessories
1.4436
316
Pos.
Component
Material
487
Base stand, horizontal 1
Cast iron or steel
182b
Screw
Stainless steel
1.4436
316
701
Auto-coupling base unit
Cast iron2
184
Screw
Stainless steel
1.4436
316
702
Guide rail bracket
Cast iron2
703
Guide claw
Cast iron2
Stainless steel
1.4436
316
762
Base plate, vertical
Cast iron or steel
187
Circlip
187a
Washer
188
Circlip
190
Lifting bracket
Steel
190b
Screw
Stainless steel
193
Plug
Stainless steel
194
O-ring
NBR rubber
197
Washer
1
1.4436
316
Stainless steel
1.4436
316
1.4436
316
198
Rubber seal
248
Screw
Stainless steel
248a
Screw
Stainless steel
2
Pumps of installation type H include the standard horizontal stand.
Pumps with material code G or Q include a painted-steel stand. If
another horizontal stand is required, order a pump of installation
type D together with the required stand.
Available in stainless steel (custom-built option).
8. Product description
Features
Bearings
SmartTrim
On conventional pumps, maintaining factory-set
impeller clearance is a time-consuming and costly
task. The pumps need to be disconnected from the
pipes and to be totally dismantled, and new parts need
to be mounted in order to maintain full pumping
efficiency. Not so with Grundfos SmartTrim!
All Grundfos heavy-duty channel-impeller pumps,
whether for submerged or dry installation, are
equipped with the unique SmartTrim impeller
clearance adjustment system. This enables you to
easily restore factory-set impeller clearance and
maintain peak pumping efficiency. All you need to do is
to tighten the adjustment screws on the exterior of the
impeller housing. This can be done on site, quickly and
easily, without dismantling the pump and without using
special tools.
Efficiency drop in %
Factory-set impeller clearance
0
3
6
12
B
Years
2
3
4
5
Fig. 13 Impeller clearance adjustment cycle
A: With Grundfos SmartTrim impeller clearance
adjustment system
B: Without impeller clearance adjustment system
SmartSeal
The Grundfos SmartSeal auto-coupling sealing
mounted on the pump outlet flange provides a
completely leak-proof connection between the pump
and the base unit of the auto-coupling system. This
optimises the efficiency of the entire pumping system
and keeps operating costs at a minimum.
TM04 2391 2508
9
1
Shaft seal
The pumps have a primary and a secondary shaft seal.
The material combination of the primary shaft seal of
all pump types is silicon carbide/silicon carbide. For
the secondary shaft seal, the material combination is
silicon carbide/carbon.
The shaft seals are placed in the oil chamber of the
pump. The oil chamber provides reliable sealing
between the pumped liquid and the motor.
The shaft seals have no springs or other parts in direct
contact with the pumped liquid. This prevents rags and
fibres from getting caught. The shaft seals are
bidirectional, meaning that they can operate in either
direction, thus allowing for opposite rotation caused by
back-flow of liquid through the pump.
Motor
A
15
The bearings are greased for life.
Main bearings: Double-row angular contact ball
bearing.
Support bearings: Single-row deep-groove ball
bearing.
Product description
8
S pumps, range 62
The motor is a watertight, totally encapsulated motor
with:
• insulation class F (155 °C)
• temperature rise class F (105 K)
• enclosure class IP68.
For motor protection and sensors, see Sensors, page
28.
Cables
The pumps have H07RN-F AT power cable as
standard or screened ATON EMC VSCCB power
cables on request.
The pumps have H07RN-F 450/750 V control cables
as standard or screened ATON VSCB 450/750 V
control cables on request.
The cables are 10 m long as standard. Other cable
lengths are available on request. See List of variants,
page 18.
The number and dimension of cables depend on the
motor size.
Motor power
[kW]
Voltage
3 x 460 V
40, 52
3 x 380/660 V
59
3 x 460 V
3 x 380/660 V
Cable size
[power + control]
2 x 4 x 10 mm2 + 1 x 7 x
1.5 mm 2
2 x 4 x 16 mm2 + 1 x 7 x
1.5 mm 2
2 x 4 x 16 mm2 + 1 x 7 x
1.5 mm 2
27
8
S pumps, range 62
Product description
Power cable
Cable type
[mm2]
Outer cable
diameter
[mm]
Weight
[kg/m]
Bending radius
[cm]
4 x 10
4 x 16
20.9 - 23.4
23.8 - 26.3
0.38
1.26
14
16
Cable type
[mm2]
Outer cable
diameter
[mm]
Weight
[kg/m]
Bending radius
[cm]
7 x 1.5
14.4 - 16.4
0.35
10
Control cable
Cable entry
Watertight PA or cast iron cable entry with soft shape
and sealing rings to prevent damage of the cable or
leaks.
Sensors
As standard, the pump is equipped with these switches
and sensors:
• three thermal switches (Klixon) or three thermal
protectors in the stator housing
• one moisture switch under the motor top cover.
An explosion-proof pump is equipped with:
• three thermal switches (Klixon) or three thermal
protectors in the stator housing
• one moisture switch under the motor top cover and
one in the stator housing in the dry end of the motor.
Customised sensor options
1. WIO (water-in-oil) sensor
The WIO sensor measures the water content in the
oil and converts the value into an analog current
signal. The two sensor conductors are for power
supply as well as for carrying the signal to the
measuring device or controller. The sensor
measures the water content from 0 to 20 %. It also
sends a signal if the water content is outside the
normal range (warning), or if there is air in the oil
chamber (alarm). The sensor is fitted in a stainless
steel tube for mechanical protection.
The sensor is either built-in with the motor (Ex) or
installed as an accessory. If the sensor is installed
externally, it is fitted in a plastic hose for mechanical
protection. The WIO sensor is connected to
Grundfos IO 113.
28
2. PVS 3 (pump vibration sensor)
The vibration sensor monitors the vibration level of
the pump by using measurements of three axes and
combining them into a single measurement
outputted in an analog current signal. The sensor
acts only as a general indicator of changes in the
vibration levels. PVS3 is to be connected to the
Grundfos IO 113 and SM 113 modules. A
substantial increase in vibration will trigger a
warning or an alarm.
An increase in vibrations can be caused by a
clogged impeller, worn bearings, closed force main
valves, etc. indicating that service inspection should
be carried out quickly in order to protect the pump
or the pipe system from being damaged.
3. Bearing temperature sensor (Pt100).
Pt100 bearing temperature sensor installed within
the motor housing. Sensors to be connected using
an SM 113 and IO 113.
Testing
All pumps are tested before leaving the factory. The
factory test report is based on ISO 9906:2012, grade
3B. Test reports can be ordered directly with the pump
or can be ordered separately based on the pump serial
number.
Other tests or third-party inspection certificates are
available on request. See List of variants, page 18.
Operating conditions
Pumps without cooling jacket in submerged
installation
• Continuous operation when the pump is fully
submerged to the top of the motor.
• Intermittent operation with maximum 20 starts per
hour when the pump is submerged to the middle of
the motor and with short periods of operation down
to the top of the pump housing.
Warning: A motor protection device must be used
to cut off the power supply in case of overheating.
Note: Explosion-proof pumps must always be fully
submerged.
Pumps with cooling jacket in submerged and dry
installation
• Continuous and intermittent operation with
maximum 20 starts per hour with water level down
to the top of the pump housing.
Pumped liquids
Level controllers
pH value: 4-10
Liquid temperature: 0-40 °C
When pumping liquids with a density and/or a
kinematic viscosity higher than that of water, use
motors with correspondingly higher outputs.
Grundfos offers dedicated pump controllers for
monitoring liquid levels in the wastewater collecting
tanks to ensure correct operation and protection of the
pumps.
Grundfos pump controllers are ideally suited to
Grundfos S pumps, and include:
• Grundfos Dedicated Controls (DC)
• Grundfos LC controllers
Sound pressure
The sound pressure level of the pump is lower than the
limiting values stated in EC Council directive 2006/42/
EC relating to machinery (the EC Machinery Directive).
Product description
8
S pumps, range 62
Grundfos DC Controllers
Motor range
Motor power [kW]
Number of poles
40
52
59
4
Explosion-proof pumps
Use explosion-proof pumps in potentially explosive
environments.
Note: All installations must be approved by the local
authorities.
•
•
•
•
•
•
EN ISO 80079-36
EN ISO 80079-37
EN 60079-0
EN 60079-1
IEC 60079-0
IEC 60079-1
Explosion protection classification (IECEx & ATEX)
• Group II, Category 2, Gas or vapor environment
• Ex db eb h mb IIB T3 or T4 Gb (Tamb = -5 °C to
+40 °C)
Operation with frequency converter
Gr-1016086
Relevant standards/regulations
Fig. 14 Grundfos Dedicated Controls control cabinet
Grundfos Dedicated Controls (DC) is a control system
designed for installation in municipal wastewater
transportation, commercial buildings or network
pumping stations with up to six wastewater pumps and
an optional mixer or a flush valve.
Advanced control and data communication are also
possible with the Grundfos Dedicated Controls system.
The control cabinets are delivered with a built-in main
switch and thermal magnetic circuit breaker.
Only temperature class T3.
Notified body
SGS Baseefa
29
8
S pumps, range 62
Product description
Features and benefits:
• Advanced Flow Calculation
• Automatic energy optimisation
• Easy installation and configuration
• Configuration wizard
• Electrical overview
• Advanced data communication
• Advanced alarm and warning priority
• Supports several languages
• Daily emptying
• Mixer control or flush valve
• User-defined functions
• Anti-blocking
• Start level variation
• Advanced pump alternation with pump groups
• SMS scheduling
• Communication to SCADA, BMS, GRM or cell
phone.
Dedicated Controls is ordered either with or without a
built-in communication interface module (CIM).
The communication module enables the possibility for
fieldbus protocol (e.g. PROFIBUS DP, Modbus RTU
and PROFINET IO/Modbus TCP) and the
communication line.
For further information about Grundfos Dedicated
Controls, please see Grundfos Product Center:
• Grundfos Dedicated Controls, brochure http://
net.grundfos.com/qr/i/96925597
• Grundfos iSolutions, brochure http://
net.grundfos.com/qr/i/99249771
• Grundfos Controls Guide, product guide http://
net.grundfos.com/qr/i/97954965
Additional features, CUE or VFD
The CUE/VFD (optional), which is either a Grundfos
variable frequency drive or a general variable
frequency drive, offers better pump protection and a
more steady flow through the pipe system.
In addition, Grundfos CUE,VFD offers these features
and benefits:
• Anti-blocking
• Automatic energy optimisation
• Specific-energy test
• Output frequency
• Monitoring of:
– voltage*
– current*
– phase sequence*
– power*
– energy*
– torque*
• Reverse start**
• Run flushing
• Stop flushing
• PID control.
* These functions are only available with a Grundfos
CUE.
** We do not recommend reversing at full speed at
any time. When reduced reverse operation settings
are set, make sure constant torque is enabled in
Variable Frequency Drive (VFD) (i.e. Grundfos
CUE, Siemens Simatic, ABB, Schneider Electric
etc.) to have maximum torque available when
reversing.
Grundfos LC controllers
The LC 231 pump controller is designed for level
control, monitoring and protection of Grundfos
pumping stations featuring one pump or two pumps,
starting direct-on-line. The LC 231 controller is
integrated in a polymer cabinet.
The LC 241 is a modular pump controller that has a
metal or polymer cabinet and can be customised
according to your needs.
It is designed for level control, monitoring and
protection of Grundfos pumping stations featuring one
pump or two pumps, starting direct-on-line with 0-23 A,
star-delta with 0-59 A or soft starter with 0-72 A.
30
IO 113
The IO 113 module is a protection module for Grundfos
wastewater pumps.
IO 113 has inputs for digital and analog pump sensors
and can stop the pump if a sensor indicates a pump
fault.
IO 113 can be connected to the Grundfos Dedicated
Controls system and allows advanced monitoring
functions:
• motor temperature
• moisture in motor
• water in oil
• insulation resistance.
8
Product description
S pumps, range 62
SM 113
The SM 113 module is used for collection and transfer
of sensor data in pumps and includes a large number
of sensors.
SM 113 can be placed either inside the pump (allowing
fewer sensor conductors out of the pump) or in the
control cabinet next to the pump installation.
SM 113 works together with IO 113 through a powerline communication using the Grundfos GENIbus
protocol.
SM 113 can collect data from:
• 3 current sensors, 4-20 mA
• 3 Pt100 thermal sensors or 3 Pt1000 thermal
sensors
• 1 PTC thermal sensor
• 1 digital input.
MP 204
The MP 204 control cabinet can be used as a standalone motor protector. MP 204 may also be
incorporated in a Grundfos Dedicated Controls system
in which it functions as a motor protector. The pump is
protected secondarily by measuring the temperature
with a Pt100 sensor and a PTC sensor or thermal
switch.
31
8
S pumps, range 62
Product description
Grundfos CUE, < 250 kW, or another
frequency converter.
Control cabinet
Dedicated Controls or PLC
IO 113 SM 113
T1 T2
G1 A1 G2 A2 K1 K2 R1 R2
D1 D2 D3 D4 D5 D6 D7 D8
PE
A Y B
Reset
ON
DIP
1 2 3 4 5 6 7 8 9 10
P1 P2 P3 P4 P5
I1 I2 I3
1 2 3 4 5 6 7 8 9 1011 1213 14
Level sensor
SM 113, optional
1 2 3 4 5 6 7 8 9 1011 1213 14
PVS3 sensor, optional
Wiring diagram
Pt100 sensor,
optional
PTC
Moisture switch
T2
Thermistor
T1
+t
+t
+t
Thermal switches
2
2
2
3
3
3
4
4
4
5
5
5
6
6
6
7
7
7
8
8
8
9
9
9
1
8
2
7
3
6
1
5
4
Moisture switches
Pt100 in lower bearing
Pt100 in stator
+t
Pt100 in upper bearing
Oil indicator
4 to 20 mA
+t
Fig. 15 Pump with frequency converter operation
32
WIO sensor, optional
TM06 8753 1117
9
1
1
8
MP 204
Product description
S pumps, range 62
MP 204
Control cabinet
Dedicated Controls or PLC
IO 113
T1 T2
G1 A1 G2 A2 K1 K2 R1 R2
D1 D2 D3 D4 D5 D6 D7 D8
SM 113
PE
A Y B
Reset
ON
DIP
1 2 3 4 5 6 7 8 9 10
P1 P2 P3 P4 P5
I1 I2 I3
1 2 3 4 5 6 7 8 9 1011 1213 14
Level sensor
SM 113, optional
1 2 3 4 5 6 7 8 9 1011 1213 14
PVS3 sensor, optional
Wiring diagram
Pt100 sensor,
optional
PTC
Moisture switch
T2
Thermistor
T1
+t
+t
+t
Thermal switches
1
2
2
2
3
3
3
4
4
4
5
5
5
6
6
6
7
7
7
8
8
8
9
9
9
1
8
2
7
3
6
1
5
4
WIO sensor, optional
Moisture switches
Pt100 in lower bearing
Pt100 in stator
+t
Pt100 in upper bearing
Oil indicator
4 to 20 mA
+t
TM06 8754 1117
9
1
Fig. 16 Pump with MP 204 motor protector
33
8
S pumps, range 62
Product description
Wiring diagrams
Thermal switch
Moisture switch and thermal
protectors
In Ex pumps 2 moisture switches
Motor
Read clockwise
from GND
Pt100 in lower bearing
Pt100 in stator
Thermistor
Supply cable conductors
176c
520d
176a
Optional equipment
Fig. 17 Wiring diagrams, pumps with one power cable
Item
Female push-on connector
2
Wire pin
3
Butt splice
4
34
Description
1
Ring connector
176a
Terminal block (power cable connections)
176c
Terminal block (sensor connections)
520d
Moisture sensor
TM04 3729 5008
Stator conductors
8
Thermal switch
In Ex pumps 2 moisture switches
Read clockwise
from GND
Product description
S pumps, range 62
Moisture switch and thermal protectors
Motor
Pt100 in lower bearing
Pt100 in stator
Thermistor
Supply cable conductors
176c
520d
176a
Optional equipment
TM043274 4008
Stator conductors
Fig. 18 Wiring diagrams, pumps with two power cables
Item
Description
1
Female push-on connector
2
Wire pin
3
Butt splice
4
Ring connector
176a
Terminal block (power cable connections)
176c
Terminal block (sensor connections)
520d
Moisture sensor
35
9
S pumps, range 62
Curve charts and technical data
9. Curve charts and technical data
The following many pages are divided into sections.
On pages 36 to 41 you will find a brief explanation of how to read the curve charts, the curve conditions, etc.
How to read the curve charts
Total pump head
H = Htotal
p
[kPa]
H
[m]
600
60
500
50
400
40
300
30
200
20
100
10
Max. efficiency mark
Pump type
62:
M:
S:
Range 62
Pressure range (Medium pressure)
Installation type
62M.S
60 Hz
S1.1
00.1
25.5
20.4
.
S1.1
00.1
25.4
00.4
.
ISO 9906:2012 3B
QH curve for the individual pump
NPSH
[m]
10
S1.100.125.400.4.
5
S1.100.125.520.4.
0
0
0
0
10
0
20
50
30
100
40
50
150
60
200
70
250
80
90
300
100
350
110
400
120
130
450
140
500
NPSH curve for all variants shown.
When sizing the pumps, add a
safety margin of at least 0.5 m
Q [l/s]
Q [m³/h]
P2
[kW]
50
S1.100.125.520.4.
40
S1.100.125.400.4.
The power curves indicate the
pump shaft power [P] for the
pumps shown
20
10
0
0
10
20
30
40
50
60
70
80
90
100
110
120
130
140
Q [l/s]
TM04 2055 1914
30
Note: The pumps are tested according to ISO 9906:2012 grade 3B tolerance. Testing equipment and measuring
instruments are designed and calibrated according to the standards mentioned. The pumps are approved according to
tolerances for entire curves, specified in grade 3B.
36
Curve conditions
The guidelines below apply to the curves shown in the
performance charts on pages 42-62.
• Tolerances according to ISO 9906:2012, grade 3B.
• The curves show pump performance with different
impeller diameters at rated speed.
• The curves apply to the pumping of airless water at
a temperature of 20 °C and a kinematic viscosity of
1 mm2/s (1 cSt).
• NPSH: The curves show average values measured
under the same conditions as the performance
curves.
When sizing the pump, add a safety margin of at
least 0.5 m.
• In case of densities other than 1000 kg/m3, the
outlet pressure is proportional to the density.
• When pumping liquids with a density higher than
1000 kg/m3, motors with correspondingly higher
outputs must be used.
Calculation of total head
The total pump head consists of the height difference
between the measuring points + the differential head +
the dynamic head.
H total
=
H geo
+ Hstat + Hdyn
Hgeo: Height difference between measuring points.
Hstat: Differential head between the inlet and the
outlet side of the pump.
Hdyn: Calculated values based on the velocity of the
pumped liquid on the inlet and the outlet side of
the pump.
These tolerance grades can be used in the contract
between the pump manufacturer and the customer, or
they can be used in a default tolerance factor which
will apply if no specific tolerance grade has been
agreed between the manufacturer and the customer.
The performance acceptance grades are explained
in Specifying acceptance grades, pages 40 and 41,
showing the performance grades related to an ordinary
pump curve.
The guarantee point
According to ISO 9906:2012, the acceptance-grade
tolerance applies to one guarantee point.
A guarantee point is defined by a guaranteed flow rate
and a guaranteed head.
In addition, either minimum total efficiency or
maximum total input power may be guaranteed at the
specified conditions.
This means that the standard sets guidelines for a duty
point guaranteed for the following:
– Q and H, or
– Q, H and total efficiency (Eta-total), or
– Q, H and total consumed power (P1).
The guarantee point is defined by a minimum of five
measured test points.
Example of a duty point test living up to ISO 9906:2012
requirements
Curve charts and technical data
9
S pumps, range 62
H [m]
20
18
16
14
12
10
Pump performance testing
8
Performance acceptance grades
6
4
2
0
0
20
40
60
80
100
120
140
160
Q [m3/h]
TM07 0448 5117
S pump testers are all capable of performing hydraulic
performance tests according to ISO 9906:2012
requirements.
ISO 9906:2012 sets standards for "rotodynamic
pumps, Hydraulic performance acceptance tests,
Grades 1, 2 and 3".
Fig. 19 Five measured test points are used to verify one
guarantee point
Six-pump-performance-test acceptance grades, 3B,
2B, 2U, 1B, 1E and 1U are defined in ISO 9906:2012.
Acceptance
grade
3B
2B
2U
1B
1E
1U
Mandatory
measurements
Optional
measurements
Q
H
P1
Eta-tot
±9%
±8%
+16 %
±5%
±5%
+10 %
±7%
±5%
+10 %
±3%
±3%
+6%
+9 %
+8 %
+16 %
+4 %
+4 %
+10 %
-7 %
-5 %
-3 %
≥ 0%
Q: Flow rate
H: Head
P1: Total consumed power
Eta-tot: Total efficiency
37
9
S pumps, range 62
The test must show that the measured pump curve
touches or passes through a tolerance surrounding the
guarantee point, as defined by the selected
acceptance grade.
Guarantee-point evaluation must be made at the rated
speed, which for S pumps means 50 Hz or 60 Hz.
Head
Grade 1U duty-point verification
Fail
Q-guaranteed
Flow
TM07 1544 1818
Pass Fail
Fig. 20 Pump curves that either pass or fail to cross the
tolerance cross of the guarantee point
The following example illustrates performance testing
according to Grade 1U.
Flow rate and head are mandatory, and efficiency or
power consumption, P1, is optional.
Tolerances for a Grade 1U test are as follows:
– Flow rate: 10 %
– Head: 6 %
– Efficiency: 0 %, only equal to or better than the
guaranteed value
– P1: 10 %
1. Q, H and Eta-tot are tested and verified
H [m]
Performance-test types for endsuction pumps
20
Two types of performance tests are available for S
pumps:
• duty-point-verification test
• curve test.
14
Tests carried out on S pumps
Duty-point-verification test, Grades 3B, 2B, 2U, 1B,
1E and 1U
This test method offers the possibility to perform a
duty-point verification of the following:
– Q and H, or
– Q, H and total efficiency (Eta-tot), or
– Q, H and total consumed power (P1).
3B
2B
2U
1B
1E
1U
Mandatory
measurements
Optional
measurements
Q
P1
H
16
12
10
8
6
4
– Tests are saved for at least five years and can be
traced using the pump’s unique serial number.
– It is not possible to change acceptance grade on
an already tested and supplied pump; if required,
a re-test of the pump is made.
– Witness testing can be arranged.
Acceptance
grade
18
Eta-tot
Standard
On request
On request
On request
On request
On request
2
0
0
200
400
600
800
1000
1200
3
Q [m /h]
TM07 1542 1618
Pass
Hguaranteed
Pass
38
What Grundfos is able to guarantee for the different
acceptance grades will be evaluated on a case-bycase basis. Contact your local sales company on this.
Grundfos makes duty-point verification according to
ISO 9906:2012 for one guarantee point at full speed,
50 or 60 Hz. The customer must tell Grundfos which
duty point to verify.
The requested duty point is verified by five measured
points.
Fig. 21 Measured values for flow rate and head
Eta-tot % [m]
80
70
60
50
40
30
20
10
0
0
200
400
600
800
1000
Q [m3/h]
Fig. 22 Measured values for total efficiency
1200
TM07 1543 1618
Curve charts and technical data
Evaluation of performance
2. Q, H and P1 tested and verified
In fig. 25 tolerance crosses according to Grade 3B
have been distributed across the complete
performance range of a pump. We generate the upper
and lower limit of the performance curve by drawing
two curves at the outlines of these crosses.
When the pump is tested, and the measured point is
located within the range between the upper and lower
limit, it meets the ISO 9906:2012 Grade 3B tolerances.
This way of qualifying the pump performance is stricter
than a duty-point-verification test for Grade 3B.
H [m]
20
18
16
14
12
10
8
4
2
0
0
200
400
600
800
1000
1200
3
Q [m /h]
TM07 1542 1618
6
Fig. 23 Measured values for flow rate and head
How does Grundfos make curve testing
for S pumps?
Grundfos applies two types of curve tests:
• a reference-curve test
• a performance-curve test.
Curve charts and technical data
9
S pumps, range 62
6
A reference curve test is made when no curve-test
report is specified with the order. Three or four test
points are measured depending on production site,
and no curve test report is supplied with the pump.
Measurements are made to maintain and observe
continuous quality and to ensure that the supplied
pump is within test grade tolerances. Test grade
tolerances are set as for Grade 3B but without
certification.
4
Example of a reference curve test
20
18
16
14
12
10
2
0
TM07 1545 1618
8
H
[m]
75
P1
[kW]
150
70
140
65
130
60
120
55
110
50
100
45
90
40
80
35
70
Curve test, Grade 3B
30
60
25
50
This test method is developed by Grundfos and is
based on ISO 9906:2012 performance acceptance
grade 3B tolerances: Q = ± 9 %, H = ± 7 %.
20
40
15
30
10
20
5
10
0
200
400
600
800
1000
1200
Q [m3/h]
Fig. 24 Measured values for consumed power
Note that other points than the guarantee point can be
measured and displayed in a curve-test report
according to Grade 3B tolerances.
0
H [m]
0
0
100
200
300
Q [l/s]
TM07 1674 1918
Reference curve test, Grade 3B
P1 [kW]
Fig. 26 Measured values for tested pump
/RZHUOLPLW
8SSHUOLPLW
6WDQGDUGFXUYH
Q [m3/h]
TM07 1515 1618
Fig. 25 Q-H curve with tolerance crosses on complete
performance range
39
9
S pumps, range 62
P1
[kW]
75
150
70
140
65
130
60
120
55
110
50
100
45
90
40
80
35
70
30
60
25
50
20
40
15
30
10
20
5
10
0
0
0
100
200
300
Q [l/s]
If the customer requires more points on the curve to be
checked, individual measurements must be made,
which is not part of the performance curve test.
Static high pressure test
All produced pumps undergo a static high pressure
test of 1.5 x PN (nominal pressure of the pump).
Specifying acceptance grades
TM07 1693 2018
Curve charts and technical data
H
[m]
Fig. 27 The values in fig. 26 calculated to reference speed
for comparison to a reference performance curve
If a pump performance report is requested at a later
stage, only reference test data are available.
Performance curve test, grade 3B
A performance curve test is made when a curve test
report is specified with the order.
The pump is tested at pre-specified flow rates and test
grade tolerances are set as for Grade 3B but without
certification.
Example of an S pump curve test
P1
[kW]
150
70
140
65
130
60
120
55
110
50
100
45
90
40
80
35
70
30
60
25
50
20
40
15
30
10
20
5
10
0
0
0
100
200
300
Q [l/s]
Acceptance grades and tolerances
Acceptance grade B
This acceptance grade refers to grades with a bilateral
tolerance on flow rate and head and with a tolerance
on efficiency.
Acceptance grade E
TM07 1674 1918
H
[m]
75
P1
[kW]
75
150
70
140
65
130
60
120
55
110
50
100
45
90
40
80
35
70
30
60
25
50
20
40
15
30
10
20
5
10
0
0
0
100
200
300
Q [l/s]
TM07 1693 2018
Fig. 28 Measured values for tested pump
H
[m]
Fig. 29 The values in fig. 28 calculated to a reference
speed for comparison to a reference performance
40
The graphs in the table on page 41 show the
tolerances as stated in the standard, related to an
ordinary pump curve. The graphs also show which
pump performance to expect if the customer, having
the same pump to start with, orders a pump with the
same guarantee point for different tolerances (B, E or
U) within the acceptance grades.
In some cases, it will not be possible to fulfil the same
guarantee point for a unilateral tolerance as it will for a
bilateral tolerance. This is indicated by the lower curve
for ‘E’ and ‘U’ grades.
If the requested guarantee point is the same for a
Grade U pump as for a Grade B pump, the
consequence of the production tolerances could be
that a larger pump is required to obtain the requested
duty point.
What Grundfos is able to guarantee for the different
acceptance grades will be evaluated on a case -bycase basis. Contact your local sales company on this.
This acceptance grade refers to a grade with a
bilateral tolerance on flow rate and head but without
tolerance on efficiency.
Acceptance grade U
This acceptance grade refers to a grade with a
unilateral tolerance on flow rate and head. For the 2U
grade there is a tolerance on efficiency. For the 1U
grade there is no tolerance on efficiency.
Note that if the acceptance grade changes from Grade
1B to 1U, the customer does not necessarily get a
better pump with a higher efficiency. More likely, he
gets a pump where the performance is always to the
positive side of the guarantee point.
9
Acceptance grade
E
B
Curve charts and technical data
S pumps, range 62
U
H
H: ±7%
Q: ±9%
Q
Grade 3
Ș
Ș: í7%
Q
H
H
H: ±5%
H: +10%
Q: ±8%
Q: +16%
Q
Q
Grade 2
Ș
Ș
Ș: í5%
Ș: í5%
Q
H
Q
H
H: ±3%
Q: ±5%
H
H: ±3%
Q: ±5%
Q
H: +6%
Q: +10%
Q
Q
Grade 1
Ș
Ș: í3%
Ș
Q
Ș: •0%
Ș
Q
Ș: •0%
Q
Certificates
Witness test
Certificates have to be confirmed for every order and
are available on request as follows:
• certificate of compliance with the order (EN 10204 2.1)
• pump test sheet.
When the pumps are being tested or are tested with a
certification, it is possible for the customer to witness
the testing procedure according to ISO 9906:2012.
The witness test is not a certificate and will not result in
a written statement from Grundfos. The witness itself is
the only guarantee that everything is carried out as
prescribed in the testing procedure.
If the customer wants to witness the test, place this
request on the order.
41
10
Performance curves and technical data
10. Performance curves and technical data
Low pressure - 3 x 380/660 V
S2.100.200.400.4 and S2.100.200.520.4
p
[kPa]
H
[m]
36
320
32
280
28
240
24
200
20
160
16
120
12
80
8
40
4
0
0
62L.S
S2.
100
.200
.52
0.4.
S2.
100
.
200
.4 0
0 .4
60 Hz
ISO 9906:2012 3B
.
NPSH
[m]
15
S2.100.200.520.4.
S2.100.200.400.4.
10
5
0
0
0
20
40
100
60
200
80
300
100
120
400
140
500
160
180
600
200
700
220
800
240
260
900
280
300
1000
Q [l/s]
Q [m³/h]
P2
[kW]
50
S2.100.200.520.4.
40
30
S2.100.200.400.4.
10
0
0
42
20
40
60
80
100
120
140
160
180
200
220
240
260
280
300
Q [l/s]
TM04 2053 1914
20
p
[kPa]
H
[m]
36
320
32
280
28
240
24
200
20
160
16
120
12
S2.
100
Performance curves and technical data
10
62L.C/D/H
.20
60 Hz
0 .5
20.
S2.
4.
100
.20
0.4
00.
4.
ISO 9906:2012 3B
NPSH
[m]
15
S2.100.200.400.4.
S2.100.200.520.4.
80
8
40
4
5
0
0
0
0
20
0
40
100
60
200
80
100
300
120
400
140
160
500
10
180
600
200
700
220
240
800
260
900
280
300
1000
Q [l/s]
Q [m³/h]
P2
[kW]
50
S2.100.200.520.4.
40
30
S2.100.200.400.4.
20
TM04 2054 1914
10
0
0
20
40
60
80
100
120
140
P1
[kW]
P2 No. of
Starting
RPM
[kW] poles
method
160
180
200
220
240
260
280
300
Q [l/s]
Motor data
Pump type
S2.100.200.400.4.62L.S.245
S2.100.200.400.4.62L.C.245
S2.100.200.400.4.62L.D.245
S2.100.200.400.4.62L.H.245
S2.100.200.520.4.62L.S.256
S2.100.200.520.4.62L.C.256
S2.100.200.520.4.62L.D.256
S2.100.200.520.4.62L.H.256
44
47
47
47
53
58
58
58
40
42
42
42
48
52
52
52
4
4
4
4
4
4
4
4
1770
1774
1774
1774
1764
1758
1758
1758
Y/D
Y/D
Y/D
Y/D
Y/D
Y/D
Y/D
Y/D
IN 1
Istart
[A]
[A]
1/2
3/4
1/1
1/2
3/4
1/1
Moment
of inertia
[kgm2]
Breakdown
torque Mmax
[Nm]
89/51
92/53
92/53
92/53
102/59
110/64
110/64
110/64
539
539
539
539
539
539
539
539
88
88
88
88
88
89
89
89
89
89
89
89
90
90
90
90
90
90
90
90
90
90
90
90
0.60
0.61
0.61
0.61
0.65
0.67
0.67
0.67
0.70
0.71
0.71
0.71
0.75
0.76
0.76
0.76
0.77
0.78
0.78
0.78
0.79
0.80
0.80
0.80
0.3000
0.3000
0.3000
0.3000
0.3000
0.3000
0.3000
0.3000
595
595
595
595
595
595
595
595
ηmotor [%]
Cos φ
1
Low/high voltage (380/660 V)
Note: Enclosure class: IP68
Pump data
Pump type
S2.100.200.400.4.62L.S/C/D/H.245
S2.100.200.520.4.62L.S/C/D/H.256
*
Impeller diameter
Maximum solids
size
Pump housing
pressure
Maximum
installation depth
Moment of inertia *
[mm]
[mm]
PN
[m]
[kgm2]
245
256
100
10
20
0,3303
0,4622
Applies to material code G (see Type key). For other material codes, please contact Grundfos.
43
10
Performance curves and technical data
S2.100.200.590.4
S
>N3D@
+
>P@
/6
6
+]
,62%
136+
>P@
3
>N:@
6
4>OV@
4>PñK@
6
44
4>OV@
TM06 7983 4316
S
>N3D@
+
>P@
/&'+
6
+]
,62%
136+
>P@
6
3
>N:@
Performance curves and technical data
10
4>OV@
4>PñK@
6
TM06 7984 4316
4>OV@
Motor data
Pump type
P1
[kW]
S2.100.200.590.4.62L.S.272
S2.100.200.590.4.62L.C.272
S2.100.200.590.4.62L.D.272
S2.100.200.590.4.62L.H.272
66
66
66
66
IN 1
59
59
59
59
4
4
4
4
1768
1768
1768
1768
Y/D
Y/D
Y/D
Y/D
Istart
ηmotor [%]
[A]
[A]
1/2
3/4
1/1
1/2
3/4
1/1
Moment
of inertia
[kgm2]
127/73
127/73
127/73
127/73
701
701
701
701
88
89
89
89
90
90
90
90
90
90
90
90
0.61
0.61
0.61
0.61
0.72
0.72
0.72
0.72
0.79
0.79
0.79
0.79
0.3800
0.3800
0.3800
0.3800
P2 No. of
Starting
RPM
[kW] poles
method
Cos φ
Breakdown
torque Mmax
[Nm]
646
646
646
646
1
Low/high voltage (380/660 V)
Note: Enclosure class: IP68
Pump data
Pump type
S2.100.200.590.4.62L.S/C/D/H.272
*
Impeller diameter
Maximum solids
size
Pump housing
pressure
Maximum
installation depth
Moment of inertia *
[mm]
[mm]
PN
[m]
[kgm2]
272
100
10
20
0,3920
Applies to material code G (see Type key). For other material codes, please contact Grundfos.
45
10
Performance curves and technical data
Low pressure - 3 x 460 V
S2.100.200.400.4 and S2.100.200.520.4
p
[kPa]
H
[m]
36
320
32
280
28
240
24
200
20
160
16
120
12
80
8
40
4
0
0
62L.S
S2.
100
.200
.52
0.4.
S2.
100
.
200
.4 0
0 .4
60 Hz
ISO 9906:2012 3B
.
NPSH
[m]
15
S2.100.200.520.4.
S2.100.200.400.4.
10
5
0
0
0
20
40
100
60
200
80
300
100
120
400
140
500
160
180
600
200
700
220
800
240
260
900
280
300
1000
Q [l/s]
Q [m³/h]
P2
[kW]
50
S2.100.200.520.4.
40
30
S2.100.200.400.4.
10
0
0
46
20
40
60
80
100
120
140
160
180
200
220
240
260
280
300
Q [l/s]
TM04 2053 1914
20
p
[kPa]
H
[m]
36
320
S2.
100
62L.C/D/H
.20
60 Hz
0 .5
20.
S2.
4.
100
.20
0.4
00.
4.
32
Performance curves and technical data
10
ISO 9906:2012 3B
280
28
240
24
200
20
160
16
120
12
80
8
40
4
5
0
0
0
NPSH
[m]
15
S2.100.200.400.4.
S2.100.200.520.4.
0
20
0
40
100
60
200
80
100
300
120
400
140
160
500
10
180
600
200
700
220
240
800
260
900
280
300
1000
Q [l/s]
Q [m³/h]
P2
[kW]
50
S2.100.200.520.4.
40
30
S2.100.200.400.4.
20
TM04 2054 1914
10
0
0
20
40
60
80
100
120
140
160
180
200
220
240
260
280
300
Q [l/s]
Motor data
Pump type
S2.100.200.400.4.62L.S.245
S2.100.200.400.4.62L.C.245
S2.100.200.400.4.62L.D.245
S2.100.200.400.4.62L.H.245
S2.100.200.520.4.62L.S.256
S2.100.200.520.4.62L.C.256
S2.100.200.520.4.62L.D.256
S2.100.200.520.4.62L.H.256
P1
P2 No. of
Starting
RPM
[kW] [kW] poles
method
44
46
46
46
53
58
58
58
40
42
42
42
48
52
52
52
4
4
4
4
4
4
4
4
1770
1774
1774
1774
1764
1758
1758
1758
[A]
[A]
1/2
3/4
1/1
1/2
3/4
1/1
73
76
76
76
85
91
91
91
571
571
571
571
571
571
571
571
87
87
87
87
88
89
89
89
89
90
90
90
90
90
90
90
90
90
90
90
90
90
90
90
0.60
0.61
0.61
0.61
0.65
0.67
0.67
0.67
0.70
0.71
0.71
0.71
0.75
0.76
0.76
0.76
0.77
0.78
0.78
0.78
0.79
0.80
0.80
0.80
0.3000
0.3000
0.3000
0.3000
0.3000
0.3000
0.3000
0.3000
Y/D
Y/D
Y/D
Y/D
Y/D
Y/D
Y/D
Y/D
Istart
η motor [%]
Moment
of inertia
[kgm2]
IN
Cos φ
Breakdown
torque Mmax
[Nm]
595
595
595
595
595
595
595
595
Note: Enclosure class: IP68
Pump data
Pump type
S2.100.200.400.4.62L.S/C/D/H.245
S2.100.200.520.4.62L.S/C/D/H.256
*
Impeller diameter
Maximum solids
size
Pump housing
pressure
Maximum
installation depth
Moment of
inertia*
[mm]
[mm]
PN
[m]
[kgm2]
245
256
100
10
20
0,3303
0,4622
Applies to material code G (see Type key). For other material codes, please contact Grundfos.
47
10
Performance curves and technical data
S2.100.200.590.4
S
>N3D@
+
>P@
/6
6
+]
,62%
136+
>P@
3
>N:@
6
4>OV@
4>PñK@
6
48
4>OV@
TM06 7983 4316
S
>N3D@
+
>P@
/&'+
6
+]
,62%
136+
>P@
6
3
>N:@
Performance curves and technical data
10
4>OV@
4>PñK@
6
TM06 7984 4316
4>OV@
Motor data
Pump type
S2.100.200.590.4.62L.S.272
S2.100.200.590.4.62L.C.272
S2.100.200.590.4.62L.D.272
S2.100.200.590.4.62L.H.272
66
66
66
66
59
59
59
59
4
4
4
4
1768
1768
1768
1768
Y/D
Y/D
Y/D
Y/D
Istart
ηmotor [%]
[A]
[A]
1/2
3/4
1/1
1/2
3/4
1/1
Moment
of inertia
[kgm 2]
127/73
127/73
127/73
127/73
701
701
701
701
88
89
89
89
90
90
90
90
90
90
90
90
0.61
0.61
0.61
0.61
0.72
0.72
0.72
0.72
0.79
0.79
0.79
0.79
0.3800
0.3800
0.3800
0.3800
IN
P1
P2 No. of
Starting
RPM
[kW] [kW] poles
method
Cos φ
Breakdown
torque Mmax
[Nm]
646
646
646
646
Note: Enclosure class: IP68
Pump data
Pump type
S2.100.200.590.4.62L.S/C/D/H.272
*
Impeller diameter
Maximum solids
size
Pump housing
pressure
Maximum
installation depth
Moment of inertia *
[mm]
[mm]
PN
[m]
[kgm2]
272
100
10
20
0,3920
Applies to material code G (see Type key). For other material codes, please contact Grundfos.
49
10
Performance curves and technical data
Medium pressure - 3 x 380/660 V
S1.100.125.400.4 and S1.100.125.520.4
p
[kPa]
H
[m]
600
60
500
50
400
40
300
30
200
20
100
10
62M.S
60 Hz
S1.1
00.1
25.5
20.4
.
0.12
5.40
0.4.
ISO 9906:2012 3B
S1.1
0
NPSH
[m]
10
S1.100.125.400.4.
5
S1.100.125.520.4.
0
0
0
0
10
0
20
50
30
100
40
50
150
60
200
70
250
80
90
300
100
350
110
400
120
130
450
140
500
Q [l/s]
Q [m³/h]
P2
[kW]
50
S1.100.125.520.4.
40
S1.100.125.400.4.
30
10
0
0
50
10
20
30
40
50
60
70
80
90
100
110
120
130
140
Q [l/s]
TM04 2055 1914
20
p
[kPa]
H
[m]
600
60
500
50
400
40
300
30
200
20
100
10
Performance curves and technical data
10
62M.C/D/H
S1.1
00.1
25.5
20.4
.
S1.10
0.125
.400.4
.
60 Hz
ISO 9906:2012 3B
NPSH
[m]
10
S1.100.125.400.4.
5
S1.100.125.520.4.
0
0
0
0
10
0
20
50
30
40
100
50
150
60
200
70
80
250
90
300
100
110
350
120
400
130
140
450
500
Q [l/s]
Q [m³/h]
P2
[kW]
50
S1.100.125.520.4.
40
S1.100.125.400.4.
30
20
TM042056 1914
10
0
0
10
20
30
40
50
60
70
80
90
IN 1
Istart
100
110
120
130
140
Q [l/s]
Breakdown
torque Mmax
[Nm]
595
595
595
595
595
595
595
595
Motor data
Pump type
S1.100.125.400.4.62M.S.292
S1.100.125.400.4.62M.C.292
S1.100.125.400.4.62M.H.292
S1.100.125.400.4.62M.D.292
S1.100.125.520.4.62M.S.308
S1.100.125.520.4.62M.C.308
S1.100.125.520.4.62M.D.308
S1.100.125.520.4.62M.H.308
44
47
47
47
53
58
58
58
40
42
42
42
48
52
52
52
4
4
4
4
4
4
4
4
1770
1774
1774
1774
1764
1758
1758
1758
Y/D
Y/D
Y/D
Y/D
Y/D
Y/D
Y/D
Y/D
ηmotor [%]
[A]
[A]
1/2
3/4
1/1
3/4
1/1
Moment
of inertia
[kgm2]
89/51
92/53
92/53
92/53
102/59
110/64
110/64
110/64
539
539
539
539
539
539
539
539
88
88
88
88
88
89
89
89
89
89
89
89
90
90
90
90
90 0.60 0.70
90 0.61 0.71
90 0.61 0.71
90 0.61 0.71
90 0.65 0.75
90 0.67 0.76
90 0.67 0.76
90 0.67 0.76
0.77
0.78
0.78
0.78
0.79
0.80
0.80
0.80
0.3000
0.3000
0.3000
0.3000
0.3000
0.3000
0.3000
0.3000
P1
P2 No. of
Starting
RPM
[kW] [kW] poles
method
Cos φ
1/2
1
Low/high voltage (380/660 V)
Note: Enclosure class: IP68
Pump data
Pump type
S1.100.125.400.4.62M.S/C/D/H.292
S1.100.125.520.4.62M.S/C/D/H.308
*
Impeller diameter
Maximum solids
size
Pump housing
pressure
Maximum
installation depth
Moment of
inertia*
[mm]
[mm]
PN
[m]
[kgm2]
292
308
100
10
20
0,4367
0,4900
Applies to material code G (see Type key). For other material codes, please contact Grundfos.
51
10
Performance curves and technical data
S1.100.125.590.4
S
>N3D@
+
>P@
06
+]
6
136+
>P@
6
3
>N:@
,62%
4>OV@
4>PñK@
6
52
4>OV@
TM06 7985 4316
S
>N3D@
+
>P@
0&'+
+]
6
,62%
136+
>P@
6
3
>N:@
Performance curves and technical data
10
4>OV@
4>PñK@
6
TM06 7986 4316
4>OV@
Motor data
Pump type
S1.100.125.590.4.62M.S.326
S1.100.125.590.4.62M.C.326
S1.100.125.590.4.62M.H.326
S1.100.125.590.4.62M.D.326
IN 1
66
66
66
66
59
59
59
59
4
4
4
4
1768
1768
1768
1768
Y/D
Y/D
Y/D
Y/D
Istart
ηmotor [%]
[A]
[A]
1/2
3/4
1/1
1/2
3/4
1/1
Moment
of inertia
[kgm2]
127/73
127/73
127/73
127/73
701
701
701
701
88
88
88
88
90
90
90
90
90
90
90
90
0.61
0.61
0.61
0.61
0.72
0.72
0.72
0.72
0.79
0.79
0.79
0.79
0.3800
0.3800
0.3800
0.3800
P1
P2 No. of
Starting
RPM
[kW] [kW] poles
method
Cos φ
Breakdown
torque Mmax
[Nm]
646
646
646
646
1
Low/high voltage (380/660 V)
Note: Enclosure class: IP68
Pump data
Pump type
S1.100.125.590.4.62M.S/C/D/H.326
*
Impeller diameter
Maximum solids
size
Pump housing
pressure
Maximum
installation depth
Moment of inertia *
[mm]
[mm]
PN
[m]
[kgm2]
326
100
10
20
0,5580
Applies to material code G (see Type key). For other material codes, please contact Grundfos.
53
10
Performance curves and technical data
Medium pressure - 3 x 460 V
S1.100.125.400.4 and S1.100.125.520.4
p
[kPa]
H
[m]
600
60
500
50
400
40
300
30
200
20
100
10
62M.S
60 Hz
S1.1
00.1
25.5
20.4
.
S1.1
00.1
25.4
00.4
.
ISO 9906:2012 3B
NPSH
[m]
10
S1.100.125.400.4.
5
S1.100.125.520.4.
0
0
0
0
10
0
20
50
30
100
40
50
150
60
200
70
250
80
90
300
100
350
110
400
120
130
450
140
500
Q [l/s]
Q [m³/h]
P2
[kW]
50
S1.100.125.520.4.
40
S1.100.125.400.4.
30
10
0
0
54
10
20
30
40
50
60
70
80
90
100
110
120
130
140
Q [l/s]
TM04 2055 1914
20
p
[kPa]
H
[m]
600
60
500
50
400
40
300
30
200
20
100
10
Performance curves and technical data
10
62M.C/D/H
S1.1
00.1
25.5
20.4
.
S1.10
0.125
.400.4
.
60 Hz
ISO 9906:2012 3B
NPSH
[m]
10
S1.100.125.400.4.
5
S1.100.125.520.4.
0
0
0
0
10
0
20
50
30
40
100
50
150
60
200
70
80
250
90
300
100
110
350
120
400
130
140
450
500
Q [l/s]
Q [m³/h]
P2
[kW]
50
S1.100.125.520.4.
40
S1.100.125.400.4.
30
20
TM042056 1914
10
0
0
10
20
30
40
50
60
70
80
90
100
110
120
130
140
Q [l/s]
Motor data
Pump type
S1.100.125.400.4.62M.S.292
S1.100.125.400.4.62M.C.292
S1.100.125.400.4.62M.D.292
S1.100.125.400.4.62M.H.292
S1.100.125.520.4.62M.S.308
S1.100.125.520.4.62M.C.308
S1.100.125.520.4.62M.D.308
S1.100.125.520.4.62M.H.308
P1
P2 No. of
Starting
RPM
[kW] [kW] poles
method
44
46
46
46
53
58
58
58
40
42
42
42
48
52
52
52
4
4
4
4
4
4
4
4
1770
1774
1774
1774
1764
1758
1758
1758
[A]
[A]
1/2
3/4
1/1
1/2
3/4
1/1
73
76
76
76
85
91
91
91
571
571
571
571
571
571
571
571
87
87
87
87
88
89
89
89
89
90
90
90
90
90
90
90
90
90
90
90
90
90
90
90
0.60
0.61
0.61
0.61
0.65
0.67
0.67
0.67
0.70
0.71
0.71
0.71
0.75
0.76
0.76
0.76
0.77
0.78
0.78
0.78
0.79
0.80
0.80
0.80
0.3000
0.3000
0.3000
0.3000
0.3000
0.3000
0.3000
0.3000
Y/D
Y/D
Y/D
Y/D
Y/D
Y/D
Y/D
Y/D
Istart
ηmotor [%]
Moment
of inertia
[kgm2]
IN
Cos φ
Breakdown
torque Mmax
[Nm]
595
595
595
595
595
595
595
595
Note: Enclosure class: IP68
Pump data
Pump type
S1.100.125.400.4.62M.S/C/D/H.292
S1.100.125.520.4.62M.S/C/D/H.308
*
Impeller diameter
Maximum solids
size
Pump housing
pressure
Maximum
installation depth
Moment of
inertia*
[mm]
[mm]
PN
[m]
[kgm2]
292
308
100
10
20
0,4367
0,4900
Applies to material code G (see Type key). For other material codes, please contact Grundfos.
55
10
Performance curves and technical data
S1.100.125.590.4
S
>N3D@
+
>P@
06
+]
6
136+
>P@
6
3
>N:@
,62%
4>OV@
4>PñK@
6
56
4>OV@
TM06 7985 4316
S
>N3D@
+
>P@
0&'+
+]
6
,62%
136+
>P@
6
3
>N:@
Performance curves and technical data
10
4>PñK@
4>OV@
6
TM06 7986 4316
4>OV@
Motor data
Pump type
S1.100.125.590.4.62M.S.326
S1.100.125.590.4.62M.C.326
S1.100.125.590.4.62M.D.326
S1.100.125.590.4.62M.H.326
Starting
P1
P2 No. of
RPM
method
[kW] [kW] poles
66
66
66
66
59
59
59
59
4
4
4
4
1768
1768
1768
1768
Y/D
Y/D
Y/D
Y/D
IN
Istart
ηmotor [%]
Cos φ
[A]
[A]
1/2
3/4
1/1
1/2
3/4
1/1
Moment
of inertia
[kgm2]
105
105
105
105
701
701
701
701
88
88
88
88
90
90
90
90
90
90
90
90
0.61
0.61
0.61
0.61
0.78
0.78
0.78
0.78
0.79
0.79
0.79
0.79
0.3800
0.3800
0.3800
0.3800
Breakdown
torque Mmax
[Nm]
646
646
646
646
Note: Enclosure class: IP68
Pump data
Pump type
S1.100.125.590.4.62M.S/C/D/H.326
*
Impeller diameter
Maximum solids
size
Pump housing
pressure
Maximum
installation depth
Moment of inertia *
[mm]
[mm]
PN
[m]
[kgm2]
326
100
10
20
0,5580
Applies to material code G (see Type key). For other material codes, please contact Grundfos.
57
10
Performance curves and technical data
High pressure - 3 x 380/660 V
S1.80.125.400.4 and S1.80.125.520.4
p
[kPa]
H
[m]
700
70
600
62H.S
S1.8
0.125
.520.4
.
60
S1.8
0.12
5.40
0
60 Hz
ISO 9906:2012 3B
500
50
400
40
300
30
15
200
20
10
100
10
0
0
.4.
NPSH
[m]
S1.80.125.520.4.
S1.80.125.400.4.
5
0
0
10
0
20
50
30
100
40
50
150
60
200
70
250
80
90
300
100
350
110
120
400
Q [l/s]
Q [m³/h]
P2
[kW]
50
S1.80.125.520.4.
40
S1.80.125.400.4.
30
10
0
0
58
10
20
30
40
50
60
70
80
90
100
110
120
Q [l/s]
TM04 2051 1914
20
p
[kPa]
H
[m]
700
70
600
Performance curves and technical data
10
62H.C/D/H
S1.8
0
S1.8
0
60
.125
.52
.125
60 Hz
0.4.
.400
ISO 9906:2012 3B
.4.
500
50
400
40
300
30
15
200
20
10
100
10
0
0
NPSH
[m]
S1.80.125.520.4.
S1.80.125.400.4.
5
0
0
10
0
20
50
30
40
100
50
150
60
70
200
80
250
90
300
100
350
110
120
400
Q [l/s]
Q [m³/h]
P2
[kW]
50
S1.80.125.520.4.
S1.80.125.400.4.
40
30
20
TM04 2052 1914
10
0
0
10
20
30
40
50
60
70
80
90
100
110
120
Q [l/s]
Motor data
Pump type
S1.80.125.400.4.62H.S.320
S1.80.125.400.4.62H.C.320
S1.80.125.400.4.62H.D.320
S1.80.125.400.4.62H.H.320
S1.80.125.520.4.62H.S.334
S1.80.125.520.4.62H.C.334
S1.80.125.520.4.62H.D.334
S1.80.125.520.4.62H.H.334
IN 1
44
47
47
47
53
58
58
58
40
42
42
42
48
52
52
52
4
4
4
4
4
4
4
4
1770
1774
1774
1774
1764
1758
1758
1758
Y/D
Y/D
Y/D
Y/D
Y/D
Y/D
Y/D
Y/D
Istart
η motor [%]
[A]
[A]
1/2
3/4
1/1
1/2
3/4
1/1
Moment
of inertia
[kgm2]
89/51
92/53
92/53
92/53
102/59
110/64
110/64
110/64
539
539
539
539
539
539
539
539
88
88
88
88
88
89
89
89
89
89
89
89
90
90
90
90
90
90
90
90
90
90
90
90
0.60
0.61
0.61
0.61
0.65
0.67
0.67
0.67
0.70
0.71
0.71
0.71
0.75
0.76
0.76
0.76
0.77
0.78
0.78
0.78
0.79
0.80
0.80
0.80
0.3000
0.3000
0.3000
0.3000
0.3000
0.3000
0.3000
0.3000
P1
P2 No. of
Starting
RPM
[kW] [kW] poles
method
Cos φ
Breakdown
torque Mmax
[Nm]
595
595
595
595
595
595
595
595
1
Low/high voltage (380/660 V)
Note: Enclosure class: IP68
Pump data
Pump type
S1.80.125.400.4.62H.S/C/D/H.320
S1.80.125.520.4.62H.S/C/D/H.334
*
Impeller diameter
Maximum solids
size
Pump housing
pressure
Maximum
installation depth
Moment of
inertia*
[mm]
[mm]
PN
[m]
[kgm2]
320
334
80
10
20
0,5613
0,6347
Applies to material code G (see Type key). For other material codes, please contact Grundfos.
59
10
Performance curves and technical data
High pressure - 3 x 380/660 V
S1.80.125.590.4
S
>N3D@
+
>P@
+6
+]
6
,62%
136+
>P@
6
3
>N:@
4>OV@
4>PñK@
6
60
4>OV@
TM04 6448 1914
S
>N3D@
+
>P@
+&'+
+]
6
Performance curves and technical data
10
,62%
136+
>P@
6
3
>N:@
4>OV@
4>PñK@
6
TM04 9815 1914
4>OV@
Motor data
Pump type
S1.80.125.590.4.62H.S.351
S1.80.125.590.4.62H.C.351
S1.80.125.590.4.62H.D.351
S1.80.125.590.4.62H.H.351
IN 1
66
66
66
66
59
59
59
59
4
4
4
4
1768
1768
1768
1768
Y/D
Y/D
Y/D
Y/D
Istart
η motor [%]
[A]
[A]
1/2
3/4
1/1
1/2
3/4
1/1
Moment
of inertia
[kgm2]
127/73
127/73
127/73
127/73
701
701
701
701
88
88
88
88
90
90
90
90
90
90
90
90
0.61
0.61
0.61
0.61
0.72
0.72
0.72
0.72
0.79
0.79
0.79
0.79
0.3800
03800
0.3800
0.3800
P1
P2 No. of
Starting
RPM
[kW] [kW] poles
method
Cos φ
Breakdown
torque Mmax
[Nm]
646
646
646
646
1
Low/high voltage (380/660 V)
Note: Enclosure class: IP68
Pump data
Pump type
S1.80.125.590.4.62H.S/C/D/H.351
*
Impeller diameter
Maximum solids
size
Pump housing
pressure
Maximum
installation depth
Moment of inertia *
[mm]
[mm]
PN
[m]
[kgm2]
351
80
10
20
0,7360
Applies to material code G (see Type key). For other material codes, please contact Grundfos.
61
10
Performance curves and technical data
High pressure - 3 x 460 V
S1.80.125.400.4 and S1.80.125.520.4
p
[kPa]
H
[m]
700
70
600
62H.S
S1.8
0.125
.520.4
.
60
S1.8
0.12
5.40
0
60 Hz
ISO 9906:2012 3B
500
50
400
40
300
30
15
200
20
10
100
10
0
0
.4.
NPSH
[m]
S1.80.125.520.4.
S1.80.125.400.4.
5
0
0
10
0
20
50
30
100
40
50
150
60
200
70
250
80
90
300
100
350
110
120
400
Q [l/s]
Q [m³/h]
P2
[kW]
50
S1.80.125.520.4.
40
S1.80.125.400.4.
30
10
0
0
62
10
20
30
40
50
60
70
80
90
100
110
120
Q [l/s]
TM04 2051 1914
20
p
[kPa]
H
[m]
700
70
600
Performance curves and technical data
10
62H.C/D/H
S1.8
0
S1.8
0
60
.125
.52
.125
60 Hz
0.4.
.400
ISO 9906:2012 3B
.4.
500
50
400
40
300
30
15
200
20
10
100
10
0
0
NPSH
[m]
S1.80.125.520.4.
S1.80.125.400.4.
5
0
0
10
0
20
50
30
40
100
50
150
60
70
200
80
250
90
300
100
350
110
120
400
Q [l/s]
Q [m³/h]
P2
[kW]
50
S1.80.125.520.4.
S1.80.125.400.4.
40
30
20
TM04 2052 1914
10
0
0
10
20
30
40
50
60
70
80
90
100
110
120
Q [l/s]
Motor data
Pump type
S1.80.125.400.4.62H.S.320
S1.80.125.400.4.62H.C.320
S1.80.125.400.4.62H.D.320
S1.80.125.400.4.62H.H.320
S1.80.125.520.4.62H.S.334
S1.80.125.520.4.62H.C.334
S1.80.125.520.4.62H.D.334
S1.80.125.520.4.62H.H.334
P1
P2 No. of
Starting
RPM
[kW] [kW] poles
method
44
46
46
46
53
58
58
58
40
42
42
42
48
52
52
52
4
4
4
4
4
4
4
4
1770
1774
1774
1774
1764
1758
1758
1758
[A]
[A]
1/2
3/4
1/1
1/2
3/4
1/1
73
76
76
76
85
91
91
91
571
571
571
571
571
571
571
571
87
87
87
87
88
88
88
88
89
90
90
90
90
90
90
90
90
90
90
90
90
90
90
90
0.60
0.61
0.61
0.61
0.65
0.67
0.67
0.67
0.70
0.71
0.71
0.71
0.75
0.76
0.76
0.76
0.77
0.78
0.78
0.78
0.79
0.80
0.80
0.80
0.3000
0.3000
0.3000
0.3000
0.3000
0.3000
0.3000
0.3000
Y/D
Y/D
Y/D
Y/D
Y/D
Y/D
Y/D
Y/D
Istart
η motor [%]
Moment
of inertia
[kgm2]
IN
Cos φ
Breakdown
torque Mmax
[Nm]
595
595
595
595
595
595
595
595
Note: Enclosure class: IP68
Pump data
Pump type
S1.80.125.400.4.62H.S/C/D/H.320
S1.80.125.520.4.62H.S/C/D/H.334
*
Impeller diameter
Maximum solids
size
Pump housing
pressure
Maximum
installation depth
Moment of
inertia*
[mm]
[mm]
PN
[m]
[kgm2]
320
334
80
10
20
0,5613
0,6347
Applies to material code G (see Type key). For other material codes, please contact Grundfos.
63
10
Performance curves and technical data
S1.80.125.590.4
S
>N3D@
+
>P@
+6
+]
6
,62%
136+
>P@
6
3
>N:@
4>OV@
4>PñK@
6
64
4>OV@
TM04 6448 1914
S
>N3D@
+
>P@
+&'+
+]
6
Performance curves and technical data
10
,62%
136+
>P@
6
3
>N:@
4>OV@
4>PñK@
6
TM04 9815 1914
4>OV@
Motor data
Pump type
S1.80.125.590.4.62H.S.351
S1.80.125.590.4.62H.C.351
S1.80.125.590.4.62H.D.351
S1.80.125.590.4.62H.H.351
P1
P2 No. of
Starting
RPM
[kW] [kW] poles
method
66
66
66
66
59
59
59
59
4
4
4
4
1768
1768
1768
1768
[A]
[A]
1/2
3/4
1/1
1/2
3/4
1/1
85
91
91
91
527
527
527
527
88
88
88
88
90
90
90
90
90
90
90
90
0.61
0.61
0.61
0.61
0.72
0.72
0.72
0.72
0.79
0.79
0.79
0.79
0.3800
0.3800
0.3800
0.3800
Y/D
Y/D
Y/D
Y/D
Istart
η motor [%]
Moment
of inertia
[kgm2]
IN
Cos φ
Breakdown
torque Mmax
[Nm]
646
646
646
646
Note: Enclosure class: IP68
Pump data
Pump type
S1.80.125.590.4.62H.S/C/D/H.351
*
Impeller diameter
Maximum solids
size
Pump housing
pressure
Maximum
installation depth
Moment of inertia *
[mm]
[mm]
PN
[m]
[kgm2]
351
80
10
20
0,7360
Applies to material code G (see Type key). For other material codes, please contact Grundfos.
65
11
S pumps, range 62
Accessories (for installation)
Pump type
Installation accessories
50-70
50-70
50-70
50-70
S and C
S and C
D
H
DN 80-DN 200 without a guide claw (guide claw included in auto-coupling kit)
DN 250-DN 600 with a guide claw mounted on the pump
Pump without installation accessories (available as separate kit)
Base stand for horizontal, dry installation supplied together with the pump.
Pumps with material code G or Q include a painted-steel stand. If another horizontal stand is required, order a pump of
installation type D together with the required stand.
Description
TM06 9923 3617
TM06 9868 3417
Pictures
Intermediate guide rail bracket
Cast iron, epoxy-coated auto-coupling system complete
with:
• guide claw
• base unit
• upper guide rail bracket
• gaskets and bolts
Size
Weight
[kg]
DN 125/DN 150
95
PN
Product
number
96782145
10
DN 200
250
96641489
DN 125/DN 150
24
96105764
Adaptor for Flygt auto coupling including:
• flange seal
• bolts
10
DN 200/DN 200 - 3"
25
97908872
DN 125/DN 150
3
96829331
DN 200-DN 600
8
96255842
DN 150
51
96308238
DN 200
100
DN 250
135
For guide rails longer than 6 m
Standard pipes.
Not supplied by Grundfos
TM06 4971 3415 TM04 4156 0909
TM04 4035 0509
Guide rails
Vertical base stand (without bend).
Steel.
Base stand for horizontal, dry installation with:
• screws
• nuts
TM04 4033 0509
L
L
10
96094523
96094525
DN 150
96787496
49
DN 200
DN 250
96787497
89
96787498
Special base stand for horizontal, dry installation with
customized height.
Bend
Cast iron, epoxy-coated
66
Outlet flange
Range
Range
Range
Range
Inlet flange
Accessories
11. Accessories
Contact
Grundfos
Pipe/pump inlet
L = 220 mm
DN 150
33
L = 260 mm
DN 200
45
L = 350 mm
DN 250
64
99035997
10
99026266
99035998
Description
L
TM04 4034 0509
L
Pictures
Size
Weight
[kg]
PN
Product
number
Reducing bend
Cast iron, epoxy-coated.
Pipe/pump inlet
L = 250 mm
DN 150/DN 100
34
L = 250 mm
DN 150/DN 125
34
L = 300 mm
DN 200/DN 150
64
99036007
L = 350 mm
DN 250/DN 200
58
99036008
L = 400 mm
DN 300/DN 200
100
L = 400 mm
DN 300/DN 250
76
99036011
L = 450 mm
DN 350/DN 250
93
99036012
L = 500 mm
DN 400/DN 200
119
99036010
L = 500 mm
DN 400/DN 250
118
99036013
99036005
Accessories
11
S pumps, range 62
99036006
10
99036009
67
11
S pumps, range 62
Pictures
Description
Galvanised lifting chain with lifting link and safety hook.
Certified.
Maximum lifting capacity 3200 kg.
TM02 8862 0904 TM01 6982 3999
TM06 5110 2518
TM06 4974 3415
TM02 6126 5102
Accessories
Other accessories
Stainless steel lifting chain with lifting link and safety hook.
Certified.
Maximum lifting capacity 3200 kg.
Size
Product
number
4m
98425788
6m
98425789
8m
98425790
10 m
98425791
4m
98425805
6m
98425806
8m
98425807
10 m
98425808
Cable support bracket (case by case)
Contact
Grundfos
AMD.08.16.1730 mixer, 3 x 460 V, 60 Hz
99056115
AMD.08.16.1690 mixer, 3 x 380 V, 60 Hz
99083810
Bracket for wall mounting
2" thread
Bracket for floor mounting
2" thread
Bracket for suspended mounting
2" thread
Tube for suspended mounting, length 3 m
2" thread
10 m cable
96003332
20 m cable
96003695
10 m cable
96003421
20 m cable
96003536
Float switch
Float switch for use in potentially explosive environments.
Bracket for two float switches
96003338
Float switches with bracket
2 switches, 1 pump without alarm
3 switches, 1 pump with alarm
3 switches, 2 pumps with alarm
62500013
10 m cable
3 switches, 2 pumps with alarm
62500014
62500014
62500015
TM02 8860 0904 TM02 0670 5000
Float switches with bracket for use in potentially explosive environments
68
2 switches, 1 pump without alarm
3 switches, 1 pump with alarm
3 switches, 2 pumps with alarm
62500016
10 m cable
3 switches, 2 pumps with alarm
Bracket for level electrodes
62500017
62500017
62500018
For 38 mm mounting
pipe
91713196
12. Dimensions
Recommendation for pump
foundations
Note: This applies only to pumps above 15 kW.
All rotating equipment generates vibrations as a mass,
such as an impeller or rotor, is turning at high speeds.
Proper installation and anchorage of Grundfos pumps
and installation accessories is critical to limit vibrations
and achieve reliable, trouble-free installation. It is
important to notice that all mechanically connected
pipes, fittings and supports to the pump are part of a
single system.
The rotating mass of the entire pump, together with the
forces from the motor and hydraulics, will generate
disturbances related to the speed of the motor.
Unbalance and impeller vane pass in hydraulics are
the two most important frequencies affecting vibration.
When these frequencies coincide with the natural
frequency of the entire mechanical system, the
vibration level will increase substantially.
Pumps from Grundfos are designed and produced
according to the highest quality standards. The method
and grade of balancing is specified by the
manufacturer in order to achieve acceptable vibration
levels. Although the pump itself can withstand rather
high vibration levels under operating conditions without
considerable lifetime reduction, the pipes and
supportive structure might suffer and crack if vibration
levels are too high. Furthermore, noticeable noise
levels might be generated.
The likelihood of high vibration levels occurring is
increased in variable-speed applications where the
pump is operated over a range of speeds rather than
at a single constant speed. Most variable-speed drives
provide the possibility to exclude certain frequency
ranges to avoid operating areas with high vibrations.
To ensure acceptable vibration levels in the field, all
parts of the system must be sufficiently stiff and firmly
anchored to minimise vibrations:
• The foundation and concrete must be of adequate
strength to support the weight of the pump including
accessories, the weight of the liquid passing
through the pump and the forces generated by the
pump.
• As a rule of thumb, the mass of the concrete
foundation must be a minimum of three to five times
the mass of the supported equipment and must
have sufficient rigidity to withstand the axial,
transverse and torsional loadings generated by the
equipment.
• The foundation must be 15 cm wider than the base
plate for pumps up to 350 kW and 25 cm wider for
larger pumps.
• The concrete used in the foundation must have a
minimum tensile strength of 250 N/cm 2. Epoxy grout
must always be used to mate the pump base plate
to the foundation.
Dimensions
12
S pumps, range 62
Pull-out strengths for anchor bolts
Submerged installation on auto coupling (type S and
C):
Auto-coupling base
unit
DN 100
DN
DN
DN
DN
DN
DN
1
125/DN 150 1
200
250
300
500
600
Anchor bolts
Pull-out resistance
[kN]
5
4 x M16
8
16
30
40
40
40
4 x M24
6 x M30
Pump outlet DN 125 and base plate outlet DN 150.
Dry installation (type H and D):
Dry installation
DN
DN
DN
DN
DN
100
150
200
250
300
DN 500/DN 4001
DN 500
1
Anchor bolts
Pull-out resistance
[kN]
3 x M20
6 x M20
6 x M24
18
18
18
25
25
25
25
Base plate inlet DN 500 and pump inlet DN 400.
69
12
S pumps, range 62
Dimensions
Basic pump
Installation types S and C
D
F
A
DT2
D02 x D2N
DN2
H
E
DC02
C
Installation types D and H
D
F
D01 x D1N
DC10
MOT_H
!A
DN2
D02 x D2N
HYDR_H
H
E
DC02
C
Fig. 30 Basic pumps
70
DN1
TM04 6361 2018 - TM04 6360 2118
DT2
Note: Dimensions D01, D1N, DC10 and DN1 are equal to zero for installation types C and S because of the inlet type.
Pump type
S1.80.125.400.4.62H.C/S
S1.80.125.400.4.62H.D/H
S1.80.125.520.4.62H.C/S
S1.80.125.520.4.62H.D/H
S1.80.125.590.4.62H.C/S
S1.80.125.590.4.62H.D/H
S1.100.125.400.4.62M.C/S
S1.100.125.400.4.62M.D/H
S1.100.125.520.4.62M.C/S
S1.100.125.520.4.62M.D/H
S1.100.125.590.4.62M.C/S
S1.100.125.590.4.62M.D/H
S2.100.200.400.4.62L.C/S
S2.100.200.400.4.62L.D/H
S2.100.200.520.4.62H.C/S
S2.100.200.520.4.62H.C/S
S2.100.200.590.4.62H.C/S
S2.100.200.590.4.62H.C/S
Pump type
S1.80.125.400.4.62H.C/S
S1.80.125.400.4.62H.D/H
S1.80.125.520.4.62H.C/S
S1.80.125.520.4.62H.D/H
S1.80.125.590.4.62H.C/S
S1.80.125.590.4.62H.D/H
S1.100.125.400.4.62M.C/S
S1.100.125.400.4.62M.D/H
S1.100.125.520.4.62M.C/S
S1.100.125.520.4.62M.D/H
S1.100.125.590.4.62M.C/S
S1.100.125.590.4.62M.D/H
S2.100.200.400.4.62L.C/S
S2.100.200.400.4.62L.D/H
S2.100.200.520.4.62H.C/S
S2.100.200.520.4.62H.C/S
S2.100.200.590.4.62H.C/S
S2.100.200.590.4.62H.C/S
A
C
D
D01
D02
D1N
D2N
DC02
DC10
1460
1502
1460
1502
1460
1502
1488
1492
1488
1492
1488
1492
1496
1519
1496
1519
1496
1519
690
690
690
690
690
690
690
690
690
690
690
690
960
960
960
960
960
960
260
260
260
260
260
260
276
276
276
276
276
276
356
356
356
356
356
356
M20
M20
M20
M20
M20
M20
M20
M20
M20
19
19
19
19
19
19
19
19
19
19
22
22
24
24
24
24
24
24
8
8
8
8
8
8
12
12
12
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
210
210
210
210
216
216
210
210
210
210
216
216
295
295
295
295
298
298
240
240
240
295
295
298
350
350
362
DN1
DN 150
DN 150
DN 150
DN 200
DN 200
DN 200
DN 250
DN 250
DN 200
DN2
DN
DN
DN
DN
DN
DN
DN
DN
DN
DN
DN
DN
DN
DN
DN
DN
DN
DN
125
125
125
125
125
125
125
125
125
125
125
125
200
200
200
200
200
200
DT2
E
F
H
HYDR
H
MOT
H
22
22
22
22
22
22
22
22
22
22
22
22
26
26
26
26
26
26
440
440
440
440
440
440
440
440
440
440
440
440
660
660
660
660
660
660
523
523
523
523
523
523
552
552
552
552
552
552
646
646
646
646
646
646
230
272
230
272
230
272
245
249
245
249
245
249
240
263
240
263
240
263
315
357
315
357
315
357
343
347
343
347
343
347
351
374
351
374
351
374
1145
1145
1145
1145
1145
1145
1145
1145
1145
1145
1145
1145
1145
1145
1145
1145
1145
1145
Dimensions
12
S pumps, range 62
71
12
S pumps, range 62
Dimensions
Installation on auto-coupling system
Upper guide rail bracket dimensions
Model B
Model A
TM06 9913 3617 - TM06 9915 3617
X
X
Fig. 31 Installation dimensions for upper guide rail bracket
Auto coupling
Product number
X
[mm]
Model Size
96782145
A
DN 125/DN 150
210
96641489
B
DN 200
150
Auto-coupling dimensions
B
C
G
F
E
H
I
J
D
TM06 6497 1516
A
K
Fig. 32 Dimension for cast-iron base unit
72
Product number
Size
96782145
96641489
DN 125/DN 150
DN 200
Dimensions [mm]
A
B
C
D
E
F
G
H
I
J
K
450
485
502
710
280
365
280
535
78
89
0
86
78
175
340
500
300
430
300
430
400
710
12
S pumps, range 62
Dimensions
Pump installation dimensions
Z6
C
Z7
Z8
Z9
F
Z10
Installation S
Ex pumps
Z17G
Z17S
Installation S
Std. pumps
ZL1
ZDC1
ZDN1
Z01
Z15
S3OPR
Z11
Z23
ZL2
ZDT1
Z1
Installation C
Z2
Z3
Z16
Z4
TM04 6372 2118
Z12B
Support block height
Z12A
ZM
Fig. 33 Installation on auto-coupling system - version 1 (with support block)
Note: Height of the support block = 125 mm.
Note: Distance between the centre of the anchor bolt hole and the edge of the screw hole = 10 mm.
Pump type
C
F
S1.80.125.400.4.62H.C.xxx.G/Q
S1.80.125.400.4.62H.S.xxx.G/Q
S1.80.125.520.4.62H.C.xxx.G/Q
S1.80.125.520.4.62H.S.xxx.G/Q
S1.80.125.590.4.62H.C.xxx.G/Q
S1.80.125.590.4.62H.S.xxx.G/Q
S1.100.125.400.4.62M.C.xxx.G/Q
S1.100.125.400.4.62M.S.xxx.G/Q
S1.100.125.520.4.62M.C.xxx.G/Q
S1.100.125.520.4.62M.S.xxx.G/Q
S1.100.125.590.4.62M.C.xxx.G/Q
S1.100.125.590.4.62M.S.xxx.G/Q
690
690
690
690
690
690
690
690
690
690
690
690
523
523
523
523
523
523
552
552
552
552
552
552
Pump type
Z15
Z16
S1.80.125.400.4.62H.C.xxx.G/Q
S1.80.125.400.4.62H.S.xxx.G/Q
S1.80.125.520.4.62H.C.xxx.G/Q
S1.80.125.520.4.62H.S.xxx.G/Q
S1.80.125.590.4.62H.C.xxx.G/Q
S1.80.125.590.4.62H.S.xxx.G/Q
S1.100.125.400.4.62M.C.xxx.G/Q
S1.100.125.400.4.62M.S.xxx.G/Q
S1.100.125.520.4.62M.C.xxx.G/Q
S1.100.125.520.4.62M.S.xxx.G/Q
S1.100.125.590.4.62M.C.xxx.G/Q
S1.100.125.590.4.62M.S.xxx.G/Q
280
280
280
280
280
280
280
280
280
280
280
280
575
575
575
575
575
575
575
575
575
575
575
575
Z01
8
8
8
8
8
8
8
8
8
8
8
8
x
x
x
x
x
x
x
x
x
x
x
x
23
23
23
23
23
23
23
23
23
23
23
23
Z1
Z2
Z3
Z4
Z6
Z7
Z8
Z9
Z10
Z11
Z12A
Z12B
1435
1435
1435
1435
1435
1435
1463
1463
1463
1463
1463
1463
300
300
300
300
300
300
300
300
300
300
300
300
123
123
123
123
123
123
123
123
123
123
123
123
280
280
280
280
280
280
280
280
280
280
280
280
1261
1261
1261
1261
1261
1261
1261
1261
1261
1261
1261
1261
947
947
947
947
947
947
947
947
947
947
947
947
697
697
697
697
697
697
697
697
697
697
697
697
110
110
110
110
110
110
110
110
110
110
110
110
88
88
88
88
88
88
88
88
88
88
88
88
1605
1605
1605
1605
1605
1605
1618
1618
1618
1618
1618
1618
80
80
80
80
80
80
100
100
100
100
100
100
400
400
400
400
400
400
400
400
400
400
400
400
Z17
Z23
S3OPR
G
S
Std.
Ex
Std.
Ex
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
435
717
435
717
435
717
463
745
463
745
463
745
435
1158
435
1158
435
1158
463
1186
463
1186
463
1186
605
887
605
887
605
887
618
900
618
900
618
900
605
1328
605
1328
605
1328
618
1341
618
1341
618
1341
ZDC1
ZDN1
ZDT1
ZL1
ZL2
240
240
240
240
240
240
240
240
240
240
240
240
DN 150
DN 150
DN 150
DN 150
DN 150
DN 150
DN 150
DN 150
DN 150
DN 150
DN 150
DN 150
25
25
25
25
25
25
25
25
25
25
25
25
571
571
571
571
571
571
571
571
571
571
571
571
147
147
147
147
147
147
147
147
147
147
147
147
ZM
4
4
4
4
4
4
4
4
4
4
4
4
x
x
x
x
x
x
x
x
x
x
x
x
M16
M16
M16
M16
M16
M16
M16
M16
M16
M16
M16
M16
73
12
S pumps, range 62
Dimensions
C
Z6
Z7
Z8
Z9
Z10
F
Z17G
Z17S
ZDC1
ZL1
Z15
ZDT1
ZDN1
Installation S
Ex pumps
Installation S
Std. pumps
Z1
S3OPR
Z11
Z23
Installation C
Z01
Z16
Z12B
Z13
Z 12A
Z14
ZM
Z3
TM04 6377 2118
Z2
Z4
Fig. 34 Installation on auto-coupling system - version 2 (without support block)
Note: Z12a is the minimum recommended distance from pit bottom to bottom of pump inlet port.
Note: Z11 is the total height of the pump installed on Grundfos installation accessory in the pit.
Note: The pump in this figure might not be equal to Z12A + Z1.
Pump type
S2.100.200.400.4.62L.C.xxx.G/Q
S2.100.200.400.4.62L.S.xxx.G/Q
S2.100.200.520.4.62L.C.xxx.G/Q
S2.100.200.520.4.62L.S.xxx.G/Q
S2.100.200.590.4.62L.C.xxx.G/Q
S2.100.200.590.4.62L.S.xxx.G/Q
74
C
F
960
960
960
960
960
960
646
646
646
646
646
646
Z01
8
8
8
8
8
8
x
x
x
x
x
x
23
23
23
23
23
23
Pump type
Z13
Z14
Z15
Z16
S2.100.200.400.4.62L.C.xxx.G/Q
S2.100.200.400.4.62L.S.xxx.G/Q
S2.100.200.520.4.62L.C.xxx.G/Q
S2.100.200.520.4.62L.S.xxx.G/Q
S2.100.200.590.4.62L.C.xxx.G/Q
S2.100.200.590.4.62L.S.xxx.G/Q
200
200
200
200
200
200
86
86
86
86
86
86
365
365
365
365
365
365
485
485
485
485
485
485
Z1
Z2
Z3
Z4
Z6
Z7
Z8
Z9
Z10
Z11
Z12A
Z12B
1471
1471
1471
1471
1471
1471
430
430
430
430
430
430
200
200
200
200
200
200
535
535
535
535
535
535
1721
1721
1721
1721
1721
1721
1352
1352
1352
1352
1352
1352
1052
1052
1052
1052
1052
1052
170
170
170
170
170
170
88
88
88
88
88
88
1627
1627
1627
1627
1627
1627
156
156
156
156
156
156
196
196
196
196
196
196
ZDN1
ZDT1 ZL1
Z17
Z23
S3OPR
G
S
Std.
Ex
Std.
Ex
3
3
3
3
3
3
3
3
3
3
3
3
471
753
471
753
471
753
471
1194
471
1194
471
1194
427
709
427
709
427
709
427
1150
427
1150
427
1150
ZDC1
295
295
295
295
295
295
DN
DN
DN
DN
DN
DN
200
200
200
200
200
200
31
31
31
31
31
31
761
761
761
761
761
761
ZL2
222
222
222
222
222
222
ZM
4
4
4
4
4
4
x
x
x
x
x
x
M24
M24
M24
M24
M24
M24
12
S pumps, range 62
Dimensions
Dry, vertical installation on base stand
A
B
XDC3
DN2
X03
DC02
D2N x D02
X10
DT2
B
X13
X16
X131
X132
X17
F
X6
X15
A
X05
0
TM06 7982 2118
12
E
XM1
C
Fig. 35 Dry, vertical installation on base stand
Pump type
S1.80.125.400.4.62H.D...
S1.80.125.520.4.62H.D...
S1.80.125.590.4.62H.D...
S1.100.125.400.4.62M.D...
S1.100.125.520.4.62M.D...
S1.100.125.590.4.62M.D...
S2.100.200.400.4.62L.D...
S2.100.200.520.4.62L.D...
S2.100.200.590.4.62L.D...
C
E
F
X03
X05
X4
X5
X6
690
690
690
690
690
690
960
960
960
440
440
440
440
440
440
660
660
660
523
523
523
552
552
552
646
646
646
24
24
24
24
24
24
24
24
24
24
24
24
24
24
24
28
28
28
300
300
300
350
350
350
400
400
400
296
296
296
344
344
344
424
424
424
621
621
621
719
719
719
854
854
854
Pump type
X16
X17
XDC3
XDT1
S1.80.125.400.4.62H.D...
S1.80.125.520.4.62H.D...
S1.80.125.590.4.62H.D...
S1.100.125.400.4.62M.D...
S1.100.125.520.4.62M.D...
S1.100.125.590.4.62M.D...
S2.100.200.400.4.62L.D...
S2.100.200.520.4.62L.D...
S2.100.200.590.4.62L.D...
2098
2098
2098
2186
2186
2186
2348
2348
2348
893
893
893
968
968
968
1117
1117
1117
240
240
240
295
295
295
350
350
350
24
24
24
26
26
26
28
28
28
DN2
DN
DN
DN
DN
DN
DN
DN
DN
DN
125
125
125
125
125
125
200
200
200
X10
DN
DN
DN
DN
DN
DN
DN
DN
DN
150
150
150
200
200
200
250
250
250
X13
X131
X132
X15
450
450
450
525
525
525
600
600
600
150
150
150
175
175
175
200
200
200
120
120
120
120
120
120
150
150
150
520
520
520
606
606
606
692
692
692
DC02
D02
D2N
DT2
210
210
216
210
210
216
295
295
298
19
19
20
19
19
22
24
24
24
8
8
8
8
8
8
8
8
8
22
22
22
22
22
22
26
26
26
XM1
M20
M20
M20
M20
M20
M20
M24
M24
M24
x
x
x
x
x
x
x
x
x
6
6
6
6
6
6
6
6
6
75
12
S pumps, range 62
Dimensions
Dry, horizontal installation on base stand
DC2
DN2
D2N x
D02
Q2
DT2
QDC1
Q3
QDN1
D1N x
D01
Q4
Q10
Q1
QZ1
F
D
Q6
Q5
TM04 2414 2018
Q8
Q03
Fig. 36 Dry, horizontal installation on base stand
D
F
∅ Q03
Q1
Q2
Q3
Q4
Q5
Q6
Q8
Q10
D1N
S1.80.125.400.4.62H.H
S1.80.125.520.4.62H.H
S1.80.125.590.4.62H.H
S1.100.125.400.4.62M.H
S1.100.125.520.4.62M.H
S1.100.125.590.4.62M.H
S2.100.200.400.4.62L.H
S2.100.200.520.4.62L.H
S2.100.200.590.4.62L.H
260
260
260
276
276
276
356
356
356
523
523
523
552
552
552
646
646
646
18
18
18
18
18
18
18
18
18
1495
1495
1495
1485
1485
1485
1512
1512
1512
290
290
290
267
267
267
281
281
281
815
815
815
815
815
815
1035
1035
1035
375
375
375
375
375
375
375
375
375
115
115
115
115
115
115
115
115
115
500
500
500
500
500
500
500
500
500
390
390
390
390
390
390
390
390
390
815
815
815
815
815
815
1015
1015
1015
8
8
8
8
8
8
12
12
12
Pump type
QDC1
QDN1
Q01
QZ1
DN1
DN2
DC2
DT2
QZ1
240
240
240
295
295
298
350
350
362
150
150
150
200
200
200
250
250
200
M20
M20
M20
M20
M20
M20
M20
M20
M20
18
18
18
18
18
18
18
18
18
150
150
150
200
200
200
250
250
200
125
125
125
125
125
125
200
200
200
210
210
216
210
210
216
295
295
298
22
22
22
22
22
22
26
26
26
18
18
18
18
18
18
18
18
18
Pump type
S1.80.125.400.4.62H.H
S1.80.125.520.4.62H.H
S1.80.125.590.4.62H.H
S1.100.125.400.4.62M.H
S1.100.125.520.4.62M.H
S1.100.125.590.4.62M.H
S2.100.200.400.4.62L.H
S2.100.200.520.4.62L.H
S2.100.200.590.4.62L.H
76
13
S pumps, range 62
Weights
13. Weights
Weights include 10 m cable.
Pump type
S1.80.125.400.4.62H.S.320
S1.80.125.400.4.62H.C.320
S1.80.125.400.4.62H.D.320
S1.80.125.400.4.62H.H.320
S1.80.125.520.4.62H.S.334
S1.80.125.520.4.62H.C.334
S1.80.125.520.4.62H.D.334
S1.80.125.520.4.62H.H.334
S1.80.125.590.4.62H.S.351
S1.80.125.590.4.62H.C.351
S1.80.125.590.4.62H.D.351
S1.80.125.590.4.62H.H.351
S1.100.125.400.4.62M.S.292
S1.100.125.400.4.62M.C.292
S1.100.125.400.4.62M.H.292
S1.100.125.400.4.62M.D.292
S1.100.125.520.4.62M.S.308
S1.100.125.520.4.62M.C.308
S1.100.125.520.4.62M.D.308
S1.100.125.520.4.62M.H.308
S1.100.125.590.4.62M.S.326
S1.100.125.590.4.62M.C.326
S1.100.125.590.4.62M.H.326
S1.100.125.590.4.62M.D.326
S2.100.200.400.4.62L.S.245
S2.100.200.400.4.62L.C.245
S2.100.200.400.4.62L.D.245
S2.100.200.400.4.62L.H.245
S2.100.200.520.4.62L.S.256
S2.100.200.520.4.62L.C.256
S2.100.200.520.4.62L.D.256
S2.100.200.520.4.62L.H.256
S2.100.200.590.4.62L.S.272
S2.100.200.590.4.62L.C.272
S2.100.200.590.4.62L.D.272
S2.100.200.590.4.62L.H.272
Weight
[kg]
600
660
720
720
620
680
720
740
620
680
740
740
600
660
720
720
660
720
720
780
620
680
740
740
640
700
770
770
660
730
770
790
660
730
790
790
77
14
S pumps, range 62
Flange forces
14. Flange forces
The flange forces and moments are according to EN
ISO 5199.
Forces can be found for both horizontal and vertical
installations in Table B.3 in EN ISO 5199 by selecting
the correct flange dimension. Forces cannot be used
directly for end-suction wastewater pumps without
using a coefficient which can be found in Table B.5 in
EN ISO 5199 by selecting the correct pump family.
For Grundfos wastewater pumps the pump families
and coefficients are as stated below.
Horizontal installations
Z
Y
Z
Y
Horizontally installed pumps
Pump family A4 = Coefficient 0.35
X
Vertically installed pumps
Pump family 10A = Coefficient 0.30
Vertical installations
Z
Y
X
Base unit
Y
X
Fig. 37 Pump characteristics
78
TM06 4901 3115 - TM06 4903 3115 - TM06 4902 3115
Z
15
S pumps, range 62
Grundfos Product Center
15. Grundfos Product Center
Online search and sizing tool to help you make the right choice.
http://product-selection.grundfos.com
All the information you need in one place
Performance curves, technical specifications, pictures, dimensional
drawings, motor curves, wiring diagrams, spare parts, service kits,
3D drawings, documents, system parts. The Product Center displays
any recent and saved items - including complete projects - right on
the main page.
Downloads
TM07 2384
On the product pages, you can download installation and operating
instructions, data booklets, service instructions, etc. in PDF format.
1
3
4
5
TM07 2383
2
Pos. Description
1
This drop-down menu enables you to set the search function to "Products" or "Literature".
2
SIZING enables you to size a pump based on entered data and selection choices.
3
CATALOGUE gives you access to the Grundfos product catalogue.
4
REPLACEMENT enables you to find a replacement product.
Search results will include information on
the lowest purchase price
the lowest energy consumption
the lowest total life cycle cost.
5
LIQUIDS enables you to find pumps designed for aggressive, flammable or other special liquids.
79
ECM: 1307628
GRUNDFOS A/S
DK-8850 Bjerringbro . Denmark
Telephone: +45 87 50 14 00
www.grundfos.com
Trademarks displayed in this material, including but not limited to Grundfos, the Grundfos logo and “be think innovate” are registered trademarks owned by The Grundfos Group. All rights reserved.