Calculation Report for Branch Connection Reinforcement Based on ASME B31.3, para. 304.3 AMTools-Piping, Copyright 2010 by Angelo M. Tolentino Calculation Date: 4/4/2023 Input Data: Pipe Outside Diameters, Dh = 36 inch, Db = 4.5 inch Nominal Pipe Wall Thickness, tnh = 0.375 inch, tnb = 0.237 inch Design Pressure, P = 185 psi Stress Allowables, Sh = 20000 psi, Sb = 20000 psi Quality Factor, Eh = 1, Eb = 1 Weld Reduction Factor, Wh = 1, Wb = 1 Coefficient, Yh = 0.4, Yb = 0.4 Allowances, Ch = 0.063 inch, Cb = 0.063 inch Manufacturer Tolerance, Mh = 0.125, Mb = 0.125 Branch Angle (minimum 45 deg.) = 90 deg. Fillet weld leg size at branch, w1 = 0.25 inch Results: 1.0 Required pipe thickness Pressure design thickness of header, th = 0.1659 inch Pressure design thickness of branch, tb = 0.0207 inch 2.0 Calculation of Variables Header pipe thickness, measured or min. per purchase specs., Th = 0.3281 inch Branch pipe thickness, measured or min. per purchase specs., Tb = 0.2074 inch Height of reinforcement zone outside of run pipe w/o repad, L4 = 0.3609 inch Effective length removed from pipe at branch, d1 = 4.2113 inch Half-width of reinforcement zone, d2 = 4.2113 inch Min. weld throat requirement, tc = 0.1659 inch Min. weld leg requirement at branch, w2 = 0.2346 inch 3.0 Reinforcement area calculations Reinforcement area required, A1 = 0.6986 inch Reinforcement area available in header pipe wall, A2 = 0.4179 inch Reinforcement area available in branch pipe wall, A3= 0.0893 inch Reinforcement area due to welds and other reinforcement, A4 = 0.0625 inch Available area for reinforcement = 0.5697 inch 4.0 Reinforcement pad design calculations Minimum thickness of reinforcing pad, tr = 0.375 inch Reinforcing pad design width, wr = 1.1250 inch Height of reinforcement zone outside of run pipe with repad = 0.6628 inch Reinforcing pad minimum length, along header axis = 4.8438 inch Minimum weld leg requirement at repad, w3 = 0.2652 inch Minimum reinforcing pad height, rh = 0.3750 inch Minimum reinforcing pad width, rw = 0.1719 inch Maximum reinforcing pad width, max. rw = 1.9613 inch Area reinforcement added by reinforcing pad, A5 = 0.8438 inch Available area of reinforcement including repad = 1.4134 inch **ACCEPTABLE. Reinforcing pad design is within limits.