Uploaded by nunnakron

AED-WRD-001 Wiring Diagram for Machines

advertisement
PROJECT DOC. NO.
TOTAL
AED-WRD-001
6
SHEET
Screw Compressor
SERVICE :
DOCUMENT TITLE :
Wiring Diagram for Machines
ADVANCE ENERGY DEVELOPMENT CO., LTD (AED)
Klong Khlung District, Kamphaeng Phet Province 62120
Atlas Copco (Thailand) Limited (ACT)
P/O NO. :
AED(AED)-PO2303045
Project Doc. No.:
AED-WRD-001
Rev : 1
1
3-May-23
For Approval
Wasutida J.
Teerasut P.
Teerasut P.
Teerasut P.
REV.
DATE
DESCRIPTION
MADE
CHECKED
APPROVED
AUTH' D
Wiring Diagram
For Air Compressor
(GA11VSDIPM)
2
1
3
0
1
2
3
4
5
4
5
6
7
8
9
10
11
12
13
14
15
6
16
17
18
19
20
8
7
21
22
23
24
25
26
27
28
29
30
31
10
9
32
33
34
35
36
37
38
39
40
41
42
43
A
44
1
1X6
30
A
2 4 6
2X30
A
24V
UL : Class K5
[f]
7
21
S3
120
S3'
S1'
2x31
22
32
K07
D28
AIR END
U1 V1 W1
U2
V2
W2
21
31
12
22
32
2x31
6
2X31
32
1X6
32
118
STO
C41
C42
C44
NO K06
RUN ENABLE
BR 18
GN 131
WH 130
GENERAL SHUTDOWN
K09 NO
1X6
44
GENERAL WARNING
K08 NO
1X6
Emergency stop
K07 NO
NO K05
6 5 4 3 2 1
NO K03
NO K04
BLOW OFF
2X20
K09
D28
4
C
2X31
MK5S TOUCH
A2
D0
B19
K08
D28
2
7
2X50
ANTENNA
E1
NO K02
13
DI10
14
DISupply
11
DI09
12
DI08
DI05
9
DI07
10
DI06
9
DISupply
13
DI04
DI03
DI02
K01
FAN RUNNING
14
D
2X22
44
2X26
[i]
1X6 43
B15
B15
C3
C3
1X4
2
PHASE
SEQUENCE
2X27
1 2 3 4 5 6 7 8 10
To U1 D0
MEMORY
CARD
Gnd
TT11
Gnd
TT02
Gnd
TT01
Gnd
PT20
V+
1X6
STO
115V 24V
Cooling blower
DI03
COM
S3
5
9
118
45
11
11
1
1
3
2
44
4
43
24V
44
COM
1
T1A
2
T1C
L3 L2 L1
S3
R S T PE
Power
2
U1
1x6 1x6
D0
116 DI01
31
118 [i] 120 32
2x31
2X28
44
D0
Y1 A1
NO
12
9
2
B9
DI02
3
105
12
101
36
300
1X6
36
1
D0
12 11 10 9 8 7 6 5 4 3 2 1
24 Vac
2X30
PE
U2 V2 W2
K06
16
DI01
15
Z1
K01
2x31
MANUAL/AUTOMATIC OPERATION
1X6
33
32
44
43
2X27
13
D0
U1 V1 W1
2x30 11 D17 2x30 12 111
1
2x31
[i]
1X6
32
1X4
31
S3'
1X6
31
2X30 8
30
PE
115V
1X3
21
118
L1 L2 L3
11
103
43
31
D0
D0
CONVERTER
K04
C17
2 4 6
1X0
2x30 1 C17 2x30 2 119
B
D0 22
S10 1 3 5
EMC option [l]
1X6
31
1X6
300
33
A
1X6
43
30
35
1X6
104
44
102
D0
120
CSA : HRC Form II
31
MAX. FUSE [a]
1 3 5
F0'
POTENTIAL FREE CONTACTS
(250VAC 10A AC11)
01
43
S0'
IEC : Class gL/gG
REMOTE EMERGENCY STOP [I]
100
Remote START/Pr.STOP
Emergency stop
PE
MAX. FUSE [a]
remote pressure set selection
( open = pressure set 1 )
( closed = pressure set 2 )
Customer's Installation
L1
L2
L3
2X28
1 2 3 4 5 6 8
2X24
10/100
Ethernet
2X25
IN
1X3
BR
18
WH 131
E7
GN 130
D30
To E1:2X22
E
1
2
1
5
U
V
U1 DB9 PIN
8
3
W
E1 2X22
U1
V1
W1
[e]
M
M2
PE
3
D21
SHIELD SHIELD
380...460V 50/60Hz
For RS485 Communication
M2
3
Pt..1000
F
gnd
V+
PT20
2
1
3
gnd
TT01
2
1
P
Pt..1000
Pt..1000
Pt..1000
TT 11
TT 02
Temp.sensor
motor winding
TT 01
Temp.sensor
ambient temp.
Temp.sensor
element outlet
380...460V 50/60Hz
2
gnd
1
gnd
1
PE
M
M1
TT12
HP
TT11
kW
2
0.35
PT 20
Press. transd.
delivery air
M1
1X4
SF:
1
2
PE
13
2
PE
HP
A1
A2
1
The marked feature is modified as standard configuration
05/08/2021
U
01
X1
91
5
Y1
Solenoid valve
W
This document is property of Atlas Copco AB and shall not without our permission be altered,
copied, used for manufacturing or communicated to any other person or company.
CONFIDENTIAL:
13.11 kW
Maximum
Note
Position
Modified from
Date
Intr./Appd.
Not Applicable
Parent 3D Model
Not Applicable
Ed.Version 3D
Pin configurations
Pressure transducer
1 : Supply V+
2 : Ground
3 : Signal
4 : Sealed with dummy
All materials supplied are in compliance with the requirements of the List of Prohibited Substance
SERVICE DIAGRAM
Name
GA7-15 VSD IPM
Confidentiality Class
Not Applicable
Internal
Not Applicable
ACDE
Scale
1:1
Drawn by
Blank nr.
ATLASCOPCO\INEEXTprap
Version Drwg
01
STATUS
Des checked.
Approved Internal
Family
Blank wt.
Prod checked.
N/A
Not Applicable
Approved.
A1 Compare
Not Applicable
Kg Fini wt.
0
Date
G
1102 K/
Material
Treatment
9829351801
Drawing owner
WUX
Replaces
Kg
Designation
Sheet 01
9829351636
9/3/2019 1:30:44 PM
(02)
2
1
3
5
4
6
7
8
10
9
NOTES
COMPRESSOR
A
M1 : compressor motor
M2 : fan motor (aircooled versions only)
PT20 : press. transducer delivery air
TT11 : temp. sensor element outlet
Y1 : solenoid valve
TT02 : temp. sensor Motor temp.
TT01 : temp. sensor ambient temp.
U1 : Variable-frequency drive
[a]
Maximum fuses with regard to short circuit
protection of starter. Cable section might
impose fuses of smaller value.
[b]
Power supply to be connected for:
1. CLOCKwise rotation of fanmotor
2. COUNTER CLOCKwise rotation of compr. motor
Rotation to be observed while facing the
drive end shaft of the motors.
Z1 : EMC filter
[e]
Thigthening torque of bolts:
B
Siemens contactor
metric thread size M6 4Nm
metric thread size M8X25(A/F 13) 10Nm
metric thread size M10 10Nm(Hexagon socket)
STARTER CUBICLE
E1 : Electronikon MK5s touch
F0' : fuse
S0' : main switch
S1' : remote START/Pr.STOP
S3 : emergency stop
S10 : Customer main switcher
S3' : emergency stop remote
metric thread size M12 20Nm(Hexagon socket)
metric thread size M10X30(A/F 17)
[f]
14Nm
For field wiring: use copper wire only, size AWG14
conductors with insulation 60-75°C
1X0
1X3
1X4
1X6
: supply connection
: earth connection
: connector
: connector
[i]
Optional remote emergency stop :
Replace bridge by NC contacts
of remote emergency stop.
[l]
Supply connection in function contactors size
Electronikon MK5s touch (E1)
K01 : aux. relay fan running
K04 : aux. relay blow off
K06: aux. relay Run enable
K07 : aux. relay manual/automatic operation
K08 : aux. relay general warning
K09 : aux. relay general alarm
C
Contactor size
1X0
S00
terminal block
S0
terminal block
S2
terminal block
S3
Cu
S6
Cu
S10
supply with 6 cables
D
All materials supplied are in compliance with the requirements of the List of Prohibited Substance
SERVICE DIAGRAM
1
The marked feature is modified as standard configuration
05/08/2021
U
01
X1
91
5
Name
Not Applicable
Not Applicable
W
This document is property of Atlas Copco AB and shall not without our permission be altered,
copied, used for manufacturing or communicated to any other person or company.
CONFIDENTIAL:
E
Note
Position
Modified from
Date
Intr./Appd.
Parent 3D Model
Ed.Version 3D
GA7-15 VSD IPM
Confidentiality Class
Not Applicable
Internal
Not Applicable
ACDE
Scale
1:1
Drawn by
Blank nr.
ATLASCOPCO\INEEXTprap
Version Drwg
01
STATUS
Des checked.
Approved Internal
Family
Blank wt.
Prod checked.
N/A
Not Applicable
Approved.
A1 Compare
Not Applicable
Kg Fini wt.
0
Date
G
1102 K/
Material
Treatment
9829351801
Drawing owner
WUX
Replaces
Kg
Designation
Sheet 02
9829351636
9/3/2019 1:30:45 PM
(02)
Wiring Diagram
For Refrigerant Dryer
(FX90)
2
1
3
4
5
7
6
CABLE BILL OF MATERIALS
10
2205020521 WIRE HARNESS FX60-70-90 230V CE
SIDE A
LENGTH
CABLE TYPE
mm
CABLE FOR
9
8
SIDE B
L1 mm
TERMINAL TYPE
NOTES
L2 mm
TERMINAL TYPE
MAIN SUPPLY PML
4000
3G1 FROR 450/750
80
3xPKE108
80 - 150GND
SOLENOID VALVE SL+EV
850
2x1 FROR 450/750
-
43650/B **
80
DIGITAL CONTROLLER DC
450
2x1 FROR 450/750
80
MOTOR M1
1000
3G1 FROR 450/750
180
4 x BN-FAR608 +
S2.5-M6(GND) + X2
80
1xBF-F 608P +
GF-F608P(BLUE)
100BLUE - 65BROWN
300GND
3x41802 + S1.5M4(GND)
CAPACITOR
450
2x1 FROR 450/750
50
2xRF-F608P
100BROWN - 50BLUE
1000
3G1 FROR 450/750
180
-
70
3xRF-F608P +X5
300
2x1 FROR 450/750
80
2 x BN-FA608 + 2 x X4
80
2 x 221-412
FAN
FREE CONTACT FC
DESCRIPTION
TYPE
MANUFACTOR
CODE
QUANT.
SWITCH
824082951E
SIGNAL LUX
1624221700
1
CABLE GLAND
M20X1,5
0698514121
1
LOOSE
NUT
M20x1,5
0697980953
1
LOOSE
X2
CONNECTOR
63N040
1088003857
1
X4
HOUSING
0993421506
5
X5
CONNECTOR
PA21
2203080501
3
INSULATION
GVS 30KV1.5
ID
PML
2xRF-F 608P + S1,5-M6
01
CS
ELEKTROZUBEHOR
A
3xLOOSE
94x190
2205023600
SERVICE DIAGR.
POSITION
LOOSE
1
B
X1.1
BLUE
X1.2
BLUE
BROWN
BROWN
X5
BLUE
BROWN
Label
COMPULSORY INSTALLATION
AT CUSTOMER CARE.
FUSES (FU) + DISCONNECTOR
SWITCH (SU)
C
BLUE
BROWN
BLUE
BROWN
X2
BROWN
BLUE
BROWN
GVS4KV1.5
BROWN
BLUE/BROWN
BROWN
gG
fuses type
10A
10A
10A
10A
10A
10A
BLUE
DC
5 6 7 4
1 2
9
10
11
12
T3
T2
X1.1
T1
X1.2
FREE CONTACT
Generale alarm:
5A/250Va.c. AC1
Min. Voltage > 50V
SU
copied, used for manufacturing or communicated to any other person or company.
This document is property of Atlas Copco AB and shall not without our permission be altered,
FU
CONFIDENTIAL:
GVS4KV1.5
GVS20KV1.5
01
K5
FX60(E7) 230V/50Hz
FX60(E7) 220V/60Hz
FX70(E7.5) 230V/50Hz
FX70(E7.5) 220V/60Hz
FX90(E8) 230V/50Hz
FX90(E8) 220V/60Hz
D
BLUE
K3
K4
Model
SU
DISCONNECTOR SWITCH AT
CUSTOMER CAR INSTALL.
FU
FUSES AT CUSTOMER CAR INSTALL.
PML MAIN SWITCH
SL
LEVEL SWITCH
EV
DRAIN SOLENOID VALVE
M1 COMPRESSOR MOTOR
M2 FAN MOTOR
DC DIGITAL CONTROLLER
K3
COMPRESSOR SWITCH
K4
FAN SWITCH
K5
FREE CONTACT SWITCH
C1
RUN CAPACITOR
T1
TEMPERATURE SENSOR NTC (P1)
T2
TEMPERATURE SENSOR NTC (P2)
T3
TEMPERATURE SENSOR PTC (P3)
X1
FREE CONTACT
X2
CONTROLLER CONNECTOR
X5
FAN CONNECTION
E
F
Tolerances,if not indicated,according to:
General tolerances
1350K - v
All materials supplied are in compliance with the
requirements of the List of Prohibited Substances
Note
01
Position
Modified from
Upgraded model name on the dwg. DN20054126 CID27570
Date
18/05/2020
Intr./Appd.
ar
EB
n
ba
SERVICE DIAGRAM IS
EQUIVALENT TO
2205020520
Name
SERVICE DIAGRAM
Material
See Drawing
Treatment
Not Applicable
Scale
FX60-70-90 230V CE
Internal
ACDE
Blank nr.
Replaces
ATLASCOPCO\CAIebarban
STATUS
Parent 3D Model
Ed.Version 3D
Blank wt.
A2
Approved InternalDes checked.
Prod checked.
Kg
Approved.
G
Drawing Transferred
owner
from
Compare
Family
-/-
Drawn by
Drawing format
Confidentiality class
acc. to 1102 K
Fini wt.
Kg
Date
26/02/2020
Designation
CAI
Sheet
(
)
2205023600
01
01
Download