OJON Indoor type Disconnectors Catalogue 1 OJON 4 GB OJON Indoor type Disconnectors 1...24 kV Contents General ..................................................................................................3 Technical data and ordering information Standards and Operating Conditions .............................................4 Installation .....................................................................................4 Ordering Information ......................................................................4 Rated Voltages and Voltage Withstand Levels ..............................4 Technical Data ..............................................................................5 Accessories Selection table ..............................................................................6 Earthing knives ..............................................................................7 Disconnector Control .....................................................................7 Motor Operation Mechanism UEMC 40_ .......................................7 Operating Arm ...............................................................................7 Manual Operating mechanism, alternative A, OJO-ZA 1 ................7 Manual Operating mechanism, alternative B, UEKO 2C3 ..............8 Support bearing .............................................................................9 Accessories to be ordered separately ...........................................9 Auxiliary switches .........................................................................10 Interlocking ....................................................................................12 Locking device ..............................................................................12 Locking coil ...................................................................................12 Extention shaft and support bearing ..............................................13 Fuse-bases ...................................................................................13 Dimension Drawings OJON 1-1/1000 ja OJON 1-1 A 2500 .............................................14 OJON 1-1 A 2500/E3 ja OJON 1-1 A 4000/E2 .............................15 OJON 1-10/630 E1 ja OJON 1-24/630/E ......................................16 OJON 3-1 A 1000 ja OJON 3-1/1600 ...........................................17 OJON 3-1 A 2500 ja OJON 3-1 A 4000 ........................................18 OJON 3-10/630 ja OJON 3-10/1000 .............................................19 OJON 3-10/1600 ja OJON 3-12 A 2500 .......................................20 OJON OJON 3-12 A 4000 ja OJON 3-24 A 630 ...........................21 OJON 3-20/1000 ja OJON 3-20/1600 ...........................................22 OJON 3-24 A 2500 ja OJON 3-24 A 4000 ....................................23 Terminals ......................................................................................24 Disconnector earthing knives .........................................................25 Disconnector control .....................................................................26 Auxiliary switches .........................................................................27 Installation and interlocking ...........................................................28 Extension bushing and support bearing .........................................32 Fuse-bases ...................................................................................33 Manual operating device ................................................................35 2 OJON 4 GB OJON Indoor type Disconnectors 97-1038 1...24 kV General Compact dimensions, direct current paths, double-knife construction and cast resin insulators are common to all OJON -type disconnectors. The high short circuit strength of these disconnectors is a result of these features. Contact pressure is achieved by spiral springs which compress the knives. Silver-plating prevents the contact area of the contact and knives from ageing, and keeps the temperature rise within the limits set by the standards. Owing to the double-knife construction, forces needed to operate the disconnectors remain moderate even at high rated currents. The operating levers of the disconnectors can be mounted on a flat base. Busbar joints OJONZWJ 5 and 6 may be used for disconnectors rated 2500 A and 4000 A. The frames and levers of the disconnectors are painted green, and the shaft terminals are treated with anti-rust varnish. The knives are painted red, which makes their position clearly visible and gives a pleasant look to the whole disconnector. The contacts of the disconnectors are made of copper bar for 630 A and of cast copper for 1000...4000 A. Aluminium busbars can be connected, using jointing grease, to 630...1600 A, disconnectors, OJONZWJ 5 and 6 terminals and earthing switches. Special features of OJON disconnectors high short-circuit strength versatile control devices suitable for aluminium busbars compact dimensions silver-plated contacts cast resin insulators direct current paths double-knife construction red knives position clearly indicated 3 OJON 4 GB Indoor type Disconnectors Technical data and ordering information Standards and operating conditions The disconnectors meet the requirements of IEC Publ. 129 (1984) and the Safety Regulations of the Finnish Electrical Inspectorate (Sähköturvallisuusmääräykset). In accordance with the standards, the ambient site temperature for indoor disconnectors, must be 25 oC...+35 oC, and the access of unusually high quantities of dust, smoke, caustic gasses and humidity to the site must be prevented. Disconnectors OJON 31 A 1000, OJON 31/1600, OJON 31 A 2500 and OJON 31 A 4000 have been approved by the Register of Shipping of the U.S.S.R. Mounting Normally the disconnectors are mounted in the upright position with the hinges at the bottom. Other positions are also possible provided that the operating or locking device ensure that the knives stay in the open or closed position. Wall mounting with the knives in a horizontal position must, however, be avoided, as the knives may bend down sideways from the bearings. Ordering information 1. Type and quantity. 2. Rated voltage Ur. See tables 1 and 2, pages 4 and 5. 3. Rated current Ir. 4. Rated peak withstand current Ip. Ip of the disconnector > network impulse short-circuit current Is. The distance of the nearest post insulator is shown in table 2. 5. Rated short-time withstand current Ik. Ik of the disconnector > network I1s. Ik is given in table 2 as 1 s value. Any other length of continuous short-circuit current Ik2 of the network is reduced to 1 s value with the formula below. The formula is valid when the duration of tk2 > 1s. Ik = Ik2 Ö tk2 / s. tk is the duration of Ik2. 6. Accessories: see table 3 on page 6. Operating voltage and voltage withstand levels In accordance with IEC 694 (1980) Table 1 1 kV 3.6 kV 12 kV 24 kV Lighting impulse voltage 1.2/50 ms Across the isolating distance Between phases and to earth 23 20 46 40 85 75 145 125 Power-frequency voltage 1 min Across the isolating distance Between phases and to earth 12 10 12 10 32 28 60 50 Withstand voltages 4 OJON 4 GB Highest permissible operating voltage Indoor type disconnectors Technical data and ordering information Technical data Table 2 Type Rated Rated voltage normal current Rated short-time current OJON kV kA 1s 31A1000 31/1600 31A2500 31A4000 1 1 1 1 310/630 310/1000 310/1600 312A2500 312A4000 12 12 12 12 12 324A630 320/1000 320/1600 324A2500 324A4000 24 24 24 24 24 r.m.s. A 1) 1) 1000/1250 1600/2000 2500/2900 4000/4600 Rated peak withstand current kA Distance of nearest post insulator from diconnector post insulator Isolating Weight distance Nm mm 50 80 90 90 100 120 150 150 360 400 350 350 630 1000 1600 2500 4000 31,5 40 50 60 60 80 100 100 150 150 3xa 3xa 3xa 3xa 3xa 40 45 60 150 160 630 1000 1600 2500 4000 20 30 40 60 60 50 75 100 150 150 3xa 3xa 3xa 3xa 3xa 2) 2) 2) 2) mm mm mm mm Control torque 40 + 20 50 + 20 70 + 30 130 + 40 kg 60 70 70 65 17 43 49 65 10 15 20 30 30 145 165 160 140 155 20 35 52 71 90 45 + 15 60 + 20 100 + 20 180 + 30 200 + 40 265 270 265 240 260 25 48 65 87 109 + + + + + Commercial code a = phase distance (1 ) Highest permissible operating voltage 3.6 kV, see table 1 page 4. (2 ) Higher value in acc. with IEC Publ. 408 (1972) when Un < 660 V. Note: We can also deliver disconnectors with larger phase distances than detailed in the dimension drawings. 97-1033 97-1041 97-1032 Single pole disconnector current values are the same as the corresponding three phase unit detailed in the table. OJON 31 A 1000 OJON 324 A 630 OJON310/1000 5 OJON 4 GB Indoor type disconnectors Accessories Technical data and ordering information Terminals o o OJOZMA 10 o o Page OJOZMA 38 OJON 324 A 2500 OJON 324 A 4000 OJON 320/1600 OJON 320/1000 OJON 324 A 630 OJON 312 A 4000 OJON 310/1600 OJON 310/1000 OJON 310/630 o OJONZWJ 5 1) OJONZWJ 6 1) Earthing switches OJON 31 A 4000 OJON 31 A 2500 Type OJON 31/1600 Description OJON 31 A 1000 Accessories OJON 312 A 2500 Disconnenctor OJOZMA 10 Earthing switches Table 3 24 o 24 o 7,25 OJOZMA 38 o 7, 25 Operating arm YASKA 25 o o o o o o o o o o o o o o o o 7, 26 Insulated operating rod NWAZS 5 o o o o o o o o o o o o o o o o NWAZS 6 o o o o Operating hook NWAZH 6 o o o o o o o o o o o o o o o o 7, 26 Manual operating mechanism OJOZA 1 2) o o o o o o o o o o o o o o o o 7 o o o o o o o o o o o o 8 o o o o o o o o o o o o 10 o o o o o o o o o o o o o o o o o o o o o o o o o o Auxiliary switch UEKO 2C3 OLAN_AL 1 o o o o OLAN + OLAN-ZT 4 Connecting levers + frame OJOZAY 11 4) Locking device OJO-ZE 1 3) OJO-ZE 2 3) Locking coil o o o o o o 7, 26 o o 11 o o 35 29 o o 29 o o o o o o o o o o OJOZLA 6 5) o o o o o o o o o o UEKO-ZL 1 6) o o o o o o o o o o o o OJOZLA 3 4) o o 7,26 o o 12, 30 12, 30 12, 31 Extension shaft BDAM 25 x L o o o o o o o o o o o o o o o o 13 Joint sleeve for extension shaft OJEZAA 25 o o o o o o o o o o o o o o o o 13, 32 Support bearing OJOZU 3 o o o o o o o o o o o o 13, 32 1) 2) 3) 4) 5) 6) Also applicable for aluminium busbars. Depending on the mounting of the operating mechanism, the operating lever may turn below the mounting level. Prevents the horizontally mounted disconnector from closing under its own weight. For manual operating mechanism OJO-ZA 1. Mounted on the side plate of the disconnector. For use with manual operating mechanism UEKO 2C3. 6 OJON 4 GB Accessories Earthing knives, operating arms and manual operating devices Technical data and ordering information Earthing Knives As shown in table 3 (page 6) the 630 A OJON_ disconnectors can be supplied with either an upper or lower earthing knives. Earthing knives have the same short-circuit strength as the corresponding disconnectors. 98-1060 The main switch and earthing knives are interlocked with a locking device so that they cannot be closed simultaneously. The locking device is normally on the left side of the disconnectors. A locking device prevents the earthing knife from opening and closing under its own weight. Disconnector fitted with earthing knives Disconnector control 93-1065 The following can be used as an operating mechanism for the disconnectors: operating rod NWAZS 5 (>1 kV) or NWA-ZS 6 (< 1 kV) and hook end NWAZH 6 and arm YASKA 25 manual operating mechanism OJOZA 1 or UEKO 2C3 motor-operated control mechanism UEMC 40_. Refer to catalogue 34 UEMC 36_ and 34 UEMC 44_. Motor operating mechanism UEMC 40_ Motor Operating device UEMC 40_ The type and construction of motor operating device depends on the location and accessories required. The device can be fitted to the disconnector shaft or the front of the cubicle. When mounting on the shaft, check that there is enough space between the disconnector shaft and mounting surface. When the motor operating device is fitted on the front of the cubicle, the drive is transfered using a lever system. Local electrical control (Pushbuttons) of the operating device is available. Manual operation is also possible by using an operating rod or control handle when a motor operating device is fitted. 98-1042 Operating arm 98-1039 Manual operating mechanism OJO-ZA 1 with accessories Manual operating mechanism and angle link The simplest control mechanism is an operating arm and an operating rod. Opening of the disconnector can be prevented with locking coil OJOZLA 6. Manual operating mechanism, alternative A, OJO-ZA 1 The manual operating mechanism OJOZA 1 for mounting on the front wall of the cubicle, interlocks the disconnector in the extreme positions with the help of a stall lever. A suspended pin ensures retention in these positions. The end that comes through the front panel of the cubicle is covered with a protective cover that can be locked with a padlock. The manual operating mechanism can be supplied both with locking coil OKOZLA 3 and auxiliary switch OLANAL 1. When there is no auxiliary voltage, the interlock (of the locking coil) can be opened manually. In accordance with the standards, the closing movement of the disconnector is from down-position to up-position. 7 OJON 4 GB Accessories Earthing knives, operating arms and manual operating devices Technical data and ordering information Manual operating mechanism, alternative B, UEKO 2C3 97-1048 This manual operating mechanism comprises of a beveled gear on the end of a shaft from the disconnector, a joint fitted with a position indicator on the front panel and a control tube joining the two parts. Due to the joint, the control tube can be moved through an angle of ±40 degrees from the verticle position. The tube is to be cut to a suiatble length when installing. The indicator locks the disconnector in the extreame positions. The operating mechanism may also be locking with a locking coil UEKO-ZL 1 and padlock. By turning the angle of the beveled gears the operating direction of the disconnector can be adjusted to always be the same. Ordering information Alternative A 1. Quantity and type designation. 2. Types of shaft and intermediate rods. (Dimensions for A and B given in the table below and in drawing on page 35). 3. Type of support bearing. 4. Accessories (e.g operating handle) see page 6. Alternative B 1. Quantity and type designation. 2. Tube length 2500 mm if the standard lenght of 1500 mm is too short. 3. Additional accessories on page 6. Delivery lengths Dimension A Alternatives: OJOZAA 1 x 1200 shaft 1 x 1800 , A max = 1200 mm , " = 1800 mm Alternatives: Dimension B NOTE! 8 OJON 4 GB OJOZAW 1 x 150 1 x 700 flat intermediate bar OJOZAW 2 x 1300 flat intermediate bar 2 x 1800 2 x 2800 , B max = 230 mm , " = 780 mm , " , " , " = 1380 mm = 1880 mm = 2880 mm If dimensions A and B differ from the standard dimensions the next standard size will be cut to a suitable length when mounting. Fine adjustment of the intermediate bars is between + 20 mm. Accessories Support bearing Technical data and ordering information Support bearting Description Type Application Page Support bearing OJOZU 3 OJON 310 ... 24_ 32 To be ordered separately Description Type Application, OJO-ZA 1 (UEKO 2C3) Page Auxiliary switch OLAN 6 AL 1 OLAN 9 AL 1 6 change-over contacts 9 change-over contacts 27 35 Power reduction levers and frame OJOZAY 11 For auxiliary switch 35 Locking coil OJOZLA 3 UEKO-ZL 1 Locks the manual operating mechanism (UEKO 2C3) into the extreme positions 30 Angle link YAEWK 3 Tubular intermediate bar OJZDU 7 x 1500 OJZDU 7 x 2500 Cut off to a suitable length when mounting. C can be min. 550 mm. 35 Operating handle OJOZAK 1 OJOZAK 2 UEKO-ZK 1 OJO ZA 1 OJO-ZA 1 (UEKO 2C3) 26 26 9 OJON 4 GB Auxiliary switches Technical data and ordering information Auxiliary switches Auxiliary switch OLAN-AL 1 can be fixed to the cubicle wall, in connection with manual operating mechanism or to the frame of the disconnector. The movement is transmitted from the shaft of the disconnector or manual mechanism to the switch with levers and intermediate bars. Switches are available with 6 or 9 change-over contacts. The contacts are silver-plated and are double breaking. Protection class is IP20. 97-1029 Technical details of auxiliary switches Insulation class 500 V Continious load current OLAN 6 AL 1, OLANZT 4 and YAWAS 6 fitted to OJON 3-12 A 4000 disconnector 16 A Breaking capacity over 5000 breaks when L/R < 40 ms 24 V 16 A 60 V 10 A 110 V 5A 220 V 2A Mechanical life 10 000 operations Position indication The auxiliary switch has a position indicator which can be used when adjusting the movement transmission levers. The contact diagram shows the operation of the contacts as the function of the turning angle of the control lever To be ordered separately Contact diagram Terminals and cable glands MRRNL 16 tai 21 Universal tube terminal MRPA 16 tai 21 Pica sensor RPLA 16 tai 23 For additional parts see page 11 Connection diagram The largest conductor size that can be connected is 4 square mm. 10 OJON 4 GB Auxiliary switches Additional parts Technical data and ordering information Additional Parts Parts Note Mounting of auxiliary switch Description Type To manual operating mechanism OJOZA 1 Transmission levers with frame OJOZAY 11 Adjustable lever YAWAS 6 For fixing on OJON 310...24 kV disconnector Support and intermediate link OLANZT 4 Page 35 Models of installation p.20 29 1. 630...4000 A 2. 630...4000 A 3. 630...1000 A on the left or the right side. 28 Choise of mode of installation as effect by the placing of the earthing switches, locking coil and chock absorber. OJON 3 10 + OLAN 912 only mode 3 and 4 of installation. For separate mounting Intermediate bar OJZDU 3x2000 OJZDU 4x2000 The bar is to be cut to a suitable length when mounting Adjustable lever YAWAS 6 For shaft diam. 25 28 11 OJON 4 GB Interlocking Technical data and ordering information Interlocking The use of locking devices in connection with different disconnectors is detailed in table 3, page 6. A. Disconnector interlocking when subject to gravity or short-circuit and other disturbances When operating arm controlled, the disconnectors are interlocked with locking device OJOZE_ or locking coil OKOZLA 6. When the disconnector is mounted in a horizontal plane, locking device OJOZE_ must always be used to prevent the knives from closing under their own weight. Manual operating mechanism OJOZA 1 locks the disconnector in the closed and the open position with no additional equipment. 97-1036 B. Disconnector interlocking to prevent unintentional operation Locking device, arm and auxiliary contacts fitted on OJON 1-10/630/E1 disconnector. When operating arm controlled, locking coil OJOZLA 6, which is fixed to the frame of the disconnector is used. Manual operating mechanism OJOZA 1 can be locked with a padlock or locking coil OJOZLA 3. Manual operating mechanism type UEKO 2C3 can be locked with a padlock or locking coil UEKO-ZL 1. 99-1013 Locking coils Locking coil OJO-ZLA 3 The auxiliary control voltage of locking coils (OJOZLA 3 and 6) is either DC or full-wave rectified alternating current. In the absence of voltage, the interlock can be opened by pulling the armature with the operating rod or by hand. Locking coil OJO-ZLA 3 is used with the operating mechanism while locking coil used OJOZLA 6 is fixed to the left or right side of the disconnector. Locking coil UEKO-ZL1 is to be fitted to the manual operating mechanism UEKO 2C3 position indicating device on the inside of the cubicle. 97-1050 Voltage of interlockup coil Locking coil UEKO-ZL 1 Voltage OJO-ZLA 3, 6 24 VDC 30 VDC 48 VDC 60 VDC 110 VDC 125 VDC 220 VDC 230 VAC X X X X X X X X UEKO ZL 1 Coil consumption and time constant X X X X 1) X X OJO-ZLA 3 12 W 40 ms 1) Rectifier included Ordering information 1. Type and quantity 2. Coil voltage 3. Is locking coil OJOZLA 6 on the right or the left side of the disconnector. 12 OJON 4 GB Interlocking Technical data and ordering information Extension shaft and support bearing When needed, the shaft of the disconnector can be extended with extension shaft BDAM 25 x L. Extension sleeve OJE-ZAA 25 with its spring bolt pin and 1 or 2 support bearings OJO-ZU 3 are then needed. To be ordered separately 98-1034 Extension shaft dim. 25 x L Dimension L must be given when ordering. Weight: 3.85 kg per meter Extending the shaft Fuse-bases The frame of the fuse-bases is made of steel plate and the insulators of cast resin. Fuse-links in accordance with DIN 43625 are suitable for the bases. The fuse bases can be fitted with fuse blown axiliary contacts. The auxiliary contacts are 1 NC rated at 10A. To be ordered separately 97-1034 Fuse cartridges -EBD CEF_. Refer to brochure CEF_CMF 1. Fuse changing handle O-ZHPA 5 Fuse bases 12 and 24 kV 13 OJON 4 GB Indoor type disconnector OJON 11 Dimension drawings OJON 11/1000 OJON12 1 kV 1000 A OJON 11 A 2500 107,5 285 107,5 1 kV 2500 A 70° ø 25 8 40 16 281 64 169 8 174 116 M12 OJON-ZWJ 5 M12 315 40 ø 15 M12 40 80 OJON13 120 14 OJON 4 GB 285 500 20 Indoor type disconnectors OJON 11 Dimension drawings OJON 11 A 2500/E3 OJON 15 1 kV 2500 A To be ordered separately OJON 11 A 4000/E2 OJON 16 1 kV 4000 A To be ordered separately 15 OJON 4 GB Indoor type disconnectors OJON 11 Dimension drawings OJON 110/630 E1 12 kV 630 A 60 4 8 Ø M16 15 R206 Ø 75° 25 385 230 265 345 72.5 M12 75 17.5 150 OJON18 228 20 40 110 150 292 445 OJON 124/630/E 24 kV 630 A 8 4 60 Ø M16 15 R316 90° Ø 495 455 375 25 340 75° 122.5 17.5 M12 75 OJON11 313 377 637 16 OJON 4 GB 20 40 250 110 250 Indoor type disconnectors OJON 31 Dimension drawings OJON 31A 1000 1 kV 1000 A 262 530 85 174 85 360 151 330 100 70 100 57 20 90 o 60 o 236 228 195 94 ø 25 OJON 38 ø 15 60 M12 M16 33 15 OJON 31/1600 1 kV 1600 A 310 620 195 590 200 200 167 70 6 ø 15 90° 65° 285 440 250 105,5 OJON 39 26 45 110 80 26 M16 110 20 17 M12 17 OJON 4 GB Load type disconnectors OJON 31 Dimension drawings OJON 31 A 2500 1 kV 2500 A 110 620 110 322 590 200 210 80 70 200 40 6 90° 65° 285 250 R153 105,5 ø 25 M12 ø 15 OJON310 M12 45 M12 40 145 OJON - ZWJ 5 OJON 31 A 4000 1 kV 4000 A 110 110 620 390 590 200 245 100 200 70 90 14 50 6 40 90° 285 ø 25 65° 250 123 R193 107,5 45 OJON311 ø15 18 OJON 4 GB M12 100 OJON - ZWJ 6 100 M 12 162 45 Indoor type disconnectors OJON 310 Dimension drawings OJON 310/630 12 kV 630 A 450 150 95 150 8 370 92,5 185 40 Ø R206 25 OJON 312 75 0 0 228 400 445 OJON 310/1000 12 kV 1000 A 150 150 544 260 531 230 490 220 220 100 75° 330 295 422 R210 90° 380 105 OJON313 ø 25 85 M16 60 45,5 ø 15 460 19 OJON 4 GB Indoor type disconnectors OJON 310 Dimension drawings OJON 310/1600 12 kV 1600 A 26 80 M16 310 M12 R240 90° 415 330 ø25 500 295 75° 97,5 ø25 26 220 85 220 272 OJON3_10 490 150 544 150 505 OJON 312 A 2500 12 kV 2500 A 548 700 150 107.5 80 150 640 315 40 280 280 6 60° 90° 370 390 330 R278 135 107.5 OJON 314 40 20 OJON 4 GB Ø M12 85 250 25 8 64 8 16 M12 OJON-ZWJ 5 Indoor type disconnectors OJON 312 Dimension drawings OJON 312 A 4000 12 kV 4000 A 150 595 150 700 640 350 100 280 280 45 90 45 14 14 M16 6 67° 90° 330 390 370 OJON 315 115 ø 25 R298 107,5 85 20 267 45 M12 M12 OJON-ZWJ6 OJON 324 A 630 24 kV 630 A 8 M16 ø 15 40 4 R316 90° ø 25 495 455 340 375 75° 122,5 M12 75 17.5 255 313 20 250 590 250 OJON 316 636 255 540 21 OJON 4 GB Indoor type disconnectors OJON 320 Dimension drawings OJON 320/1000 24 kV 1000 A 334 60 105 M16 4 R315 90° ø 25 435 485 525 400 75° ø 15 138 138 OJON 317 M12 280 280 85 610 250 664 635 250 OJON 320/1600 24 kV 1600 A 26 80 M16 388 M12 R340 90° 520 435 400 Ø 25 605 75° 138 Ø 15 26 85 280 280 346 OJON3_20 610 22 OJON 4 GB 250 664 240 685 Indoor type disconnectors OJON 324 Dimension drawings OJON 324 A 2500 24 kV 2500 A 720 250 840 780 390 350 80 40 250 350 20 105 6 60° 90° 500 440 ø 20 155 R388 OJON 318 480 ø 25 M12 85 107,5 40 8 64 8 16 M12 325 OJON-ZWJ 5 OJON 324 A 4000 24 kV 4000 A 840 250 775 425 100 350 45 350 14 45 90 14 M16 6 90° 67° 480 500 440 ø 25 155 R 408 M12 107,5 OJON319 250 780 45 85 342 OJON-ZWJ 6 M12 23 OJON 4 GB Terminals Dimension drawings 2500 A terminal 7,5 OJON-ZWJ 5 To be ordered as required for 2500 A disconnectors. 107,5 Silver plated electrolytic copper. 40 M12 Weight: 2.1 kg 20 20 40 20 15 80 77 20 ø 14 OJONZWJ1 40 20 40 20 20 80 4000 A terminal OJON-ZWJ 6 50 To be ordered as required for 4000 A disconnectors. Silver plated electrolytic copper. M12 40 20 M16 80 Weight: 4.45 kg OJONZWJ2 45 24 OJON 4 GB 90 118 14 100 107,5 Earthing knives Dimension drawing Disconnector earthing knives 25 90° ø25 90° 73 90° OJOZMA21 C A A B Earthing knife type Disconnector type A B C OJO-ZMA 10 OJO-ZMA 38 kg OJON 3-10/630 185 750 173 9,0 OJON 3-24 A 630 255 1090 258 10,1 Note When ordering the position of the earthing knife is to be stated (above or below). 25 OJON 4 GB Disconnector control Dimension drawings Operating rod Operation hook YASKA 25 NWA-ZS 5 NWA-ZH 6 NWAZH6 Operating arm YASKA NWAZS5 NWA-ZS 6 Weight: 1,5 kg NWAZS6 Weight: 0.9 kg Weight: 0,9 kg Operating handle Operating handle OJO-ZAK_ Angle link YAEWK 3 UEKO-ZK 1 A 570 Ø (ø25.0 (Ø 25.0uritettu) splined) OJO-ZAK 1 OJO-ZAK 2 OJON 4 GB 25 A 330 500 Weight kg 1,2 1,6 85 YAEWK OJOZ1 Type 26 Ø 117 UEKOZK1 35 15 Ø 18 Weight: 1,8 kg Auxiliary switches Dimension drawings Auxiliary switch Auxiliary switch OFC-ZA 1 OFC-ZA 2 OFCRN 24 A 3 OFCRN 12 A 3 101 OFCR21 OFCZA1 101 343 343 Auxiliary switch OLAN-AL 1 132 30 A 90° 5° Ø 5° 12 Ø 8 29 85 R45 25 100 M8 M8 48 Reikäaihio PkPk21, Pk1616 Knock-out hole 21. Pk Type OLAN 6AL1 OLAN 9 AL1 Change-over contacts A Weight kg 6 9 136 172 1,5 1,8 27 OJON 4 GB Methods of mounting Dimension drawing OJ-ZDU 3 x 2000 OJ-ZDU 4 x 2000 ZDU4 Intermediate rod ZDU3 Intermediate rod Adjustment margin + 15 mm Adjustment margin + 15 mm Weight: 1,6 kg Weight: 1,7 kg Auxiliary switch support (right) ZT4 OLAN-ZT 4 If the mounting position is not mentioned it is fitted in position 4. 28 OJON 4 GB Weight: 0,8 kg Methods of mounting and interlocking Dimension drawings Adjustable lever YAWAS YAWAS 6 +0 To be drilled when fitting Ø 5 +0,1 Weight: 0,8 kg Locking device OJO-ZE_ ZE Ø 12 hole drilled when fitting Type A Weight mm kg OJO-ZE 1 187 1,1 OJO-ZE 2 237 1,3 Ø 8 hole drilled when fitting 29 OJON 4 GB Locking Dimension drawing Locking coil OJO-ZLA 3 ZLA3 Position indicator AMP No. 180909 Weight: 1,1 kg Locking coil ZLA6 OJO-ZLA 6 +0 Ø8 +0,1Drilled when fitting Incoming cable gland can also be turned upwards. Weight: 2,3 kg 30 OJON 4 GB Position indicator Locking Dimension drawings Locking coil Front of the cubicle UEKOZL1 UEKO ZL1 31 OJON 4 GB Extension bushing and support bearing Dimension drawings Extension bushing OJE-ZAA 25 Drill when assembling Extension shaft ZAA25 Disconnectors shaft Weight: 0,52 kg 2 pcs spring pins included. Support bearing OJO-ZU 3 ZU3 Mounting To be used for 10...24 kV OJON-disconnector extension shaft support bearing. Angle iron not included. Weight: 0,35 kg 32 OJON 4 GB Fuse base for indoor use Dimension drawing Fuse base 294 OFCRN 12 A 3 M12x30/30 e = 292 Fuse link DIN 43625 276 8 233 163 Ø 17 620 Ø 15 Ø 17 95 30 180 OFCR1 366 490 20 By moving one insulator 3,6/7,2 kV e = 192 mm fuses can be fitted. The fuse base can be fitted with a blown fuse auxiliay contact, see page 27. The auxiliary switch is one NC contact. Fuse base 444 OFCRN 24 A 3 M12x30/30 e = 442 8 Fuse links DIN 43625 371 327 258 514 Ø 17 620 M12 Ø 15 95 Ø 17 30 180 OFCR2 366 20 638 33 OJON 4 GB Fuse base for indoor use Dimension drawing Fuse base OFCRN 36 A 3 539 M12x30/30 e = 537 Fuse links DIN 43625 8 478 435 365 514 620 M12 Ø 15 40 95 OFCR3 180 366 34 OJON 4 GB 20 Ø 17 720 Manual operating mechanism Dimension drawing Manual operating mechanism Drilling the front plate For removing the interlocking coil we recommend a covered hole of 100 mm diameter for service access. Diagram for cover plate fixing with 8 mm holes. OJO-ZA 1 For shaft Position indicator ZA Drill Drillø 2,2 Poraa Ø 10,2 Ø 2,2 Manual operating mechanism Poraa Drill Ø ø 1111 Øø25 25 uritettu splined 180° 180oo 180 closed Kiinni Drill Ø ø5555 Poraa UEKO 2C3 A 45 Max. Max. 40° 40 o 45 115 90oo closed 90° kiinni 90 kiinni 54 Ohjausputki ø 33,5 x 1500 mm Putken katk. pituus A - x150 mm Transmission tube Ø =33,5 1500 mm Tube length = A - 150 mm Erottimen Shaft of theakseli disconnector 35 OJON 4 GB 99-1012 Motor operating mechanism UEMC 40 K6 types mounted on the body of the disconnector. Ykkös-Offset Oy 3000, 99-10 Apparatus and Switchgear Business Unit P.O.Box 613, FIN-65101 Vaasa, Finland Phone: +358 10 22 4000 Fax: +358 10 22 44661 OJON 4 GB 99-10 99-1011 Motor operating mechanism UEMC 40 A, B ja D -types mounted on the front of the cubicle. 36 OJON 4 GB