Uploaded by paroc

9615-SBL-Z-X-DRW-X-4014

advertisement
FACADE LINE
SECTION VIEW
D009 - 2117
220
252.5
1200
M20 x 50 galvanised
(Grade 8.8) bolts
100
40
Level 01
C002 Stub 203UB30
M12 x 35 galvanised
(Grade 8.8) bolts
SSL
SSL
17070
10
250
Stiffener gusset
M24x130 A2-70 CSK set
screw (fully threaded)
M16 stud resin
anchored into slab
25mm thermal break
250
950
50mm dia holes to
aid grouting.
50
10mm thermal break C-washer
and M30 A2/70 Half Nut
92.5
110
90
C012 Stub 203UB30
110
220
260
340
M20 x 50 galvanised
(Grade 8.8) bolts
73
10mm packing
allowance. Gap
grouted after install.
320
60
30mm thick
stub plate
D010/D011/D012
positions
D003-D012 Arms - 203UB30
10mm thk plate
17150
57
10mm Thick
Top Plate
D003-D012 Arms - 203UB30
134
100
120
17150
100
15
6
Level 01
610
250
Decking Level (FDL) 17165
66
Level 01
M12 resin anchors
(A2-70) with 50x50x6
square plate washers
Rockwool infill
90
Approx. 200mm offset to L or R
2022 © Sapphire Balconies Ltd.
Do not scale from this drawing.
All dimensions in millimeters
unless stated otherwise.
We reserve the right to alter detail
to suit production.
All tolerances to be +/- 3mm
unless otherwise specified
Drawings to be read in
conjunction with specification and
detail sheets.
TF007 Anchor
30
50
D010/D011/D012
positions
30
25 thermal break zone
125
47.5
50
285
Secondary holes for
alternative fixing
points
285
PLAN VIEW
Detail applies to Block A inset balconies
L01-L02:
Balcony Type BA05-1 (Stack Ref A2-B1-2),
Anchors 1 and 3.
Balcony Type BA05-2 (Stack Ref A2-B1-3),
Anchors 1 and 3.
FRONT VIEW
200
30mm thick
rear plate
60
340
220
Existing cast-in studs to be
cut off flush at slab edge
40
Specification Notes
Level 01
65
Total of 8 req'd
Approx. 200mm offset to L or R
from original cast-in position
17150
SSL
Ø27 holes (M24 fixings)
Welds to be min 6mm fillet welds
285
160
207
17070
All steelwork assemblies to be
shot-blasted prior to galvanising.
60
Ø19 hole (M16 fixings)
133
203UB 30kg
stub
260
Galvanising to BS EN ISO 1461. Min
Thickness 85µm
Existing stub bracket to be
removed and discarded.
6mm Thick Splice Plate
DRAWING SOURCE
KEYPLAN
ORIGINATOR
Name
Designed by
Designer
Drawn by
HC
Checked
HC
Signature
Date
DRAWING TITLE
Capital Interchange Way - 530937
Anchor/Arm Detail A014 - Upper Levels
(Post-Fix Anchor)
Approved
SCALE
www.sapphire.eu.com
call 0844 88 00 553
1:10
FIRST ISSUE DATE
P01 14/07/22 Issued in response to as-built surveys received.
Rev DATE
REVISION HISTORY
--- HC HC --Dsg Drw Chk App
14/07/22
@ A3
FILE NAME
9615-SBL-Z-X-DRW-X-4014
PROPOSED STATUS
APPROVAL
PROJECT
9615
ORIGINATOR
ZONE
LEVEL
TYPE
ROLE
UNIQUE REF.
REV
SBL
Z
X
DRW
X
4014
P01
Download