Relay Control Relay 2. Type designation N JYW 1-□□/□ Rated power supply voltage Length of electrode lead-wire: L1: represents the max length of lead-wire is 1km L2: represents the max length of lead-wire is 2km Function code: N: water supply, water drainage type B: water supply and water drainage with anti-exhausted of pump type Design sequnce No. Floatless relay Company code NJYW1 Floatless Relay 1. General NJYW1 Series Floatless Relay is used in control circuit @ A.C. 50Hz/60Hz, up to 380V rated supply voltage for liquid level automatic control at places of civil water tower, high cistern, and underground conservation pool, etc. It is capable to realize automatic water supply control or water drainage control according to wiring requirement of user. This product is not applicable for level control for liquid with poor conductivity such as oil, pure water, flammable & explosive chemical liquid and high density sewage, etc. 3. Technical data Type NJYW1-NL1 One group changeover contact AC 50Hz/60Hz 36V, 110V/220V, 220V/380V Operating resistance Releasing resistance Response time Ambient temperature Power consumption Installation mode I-97 > >> AC 50Hz/60Hz 36V, 110V, 220V, 380V 24V Control electrode voltage Conductor length NJYW1-BL2 Continuous working Contact number Operating voltage NJYW1-BL1 NJYW1-NL2 Operating mode Max 1km Max 2km Max 1km ≤25kΩ ≥2kΩ Reacting: max 80ms; releasing: max 160ms -5℃~+40℃ <3VA Guide rail type or device type Max 2km Relay Control Relay 4. Wiring diagram Wiring diagram for NJYW1-NL1, NJYW1-NL2 water drainage mode 220V/380V Wiring diagram for NJYW1-NL1, NJYW1-NL2 water supply mode 110V/220V N L L1 L2 L3 N QS QS S0 S1 S2 S0 S1 S2 E1 AC110V AC220V E1 AC220V AC380V Ta Tc Tb E3 E2 Ta Tc Tb E3 E2 KM KM KM KM M M Wiring diagram for NJYW1-NL1, NJYW1-NL2 water drainage mode 110V/220V wiring diagram for NJYW1-BL1 and NJYW1-BL2 upper/lower water pool level control 220V N N L L QS QS Upper water pool S0 S1 E4 E5 E1 S0 S1 S2 AC220V E1 AC110V Ta Tc Tb E3 E2 AC220V KM Ta Tc Tb E3 E2 Lower water pool KM KM KM M M Note: IN NJYW1-BL1 or NJYW1-BL2, Ta,Tc,Tb are not one group of changeover contacts, among which Ta & Tc are one group of independent normally open contacts; Tc & Tb are one group of normally closed contacts Wiring diagram for NJYW1-NL1, NJYW1-NL2 water supply mode 220V/380V L1 L2 wiring diagram for NJYW1-BL1 and NJYW1-BL2 upper/lower water pool level control 380V L1 L2 L3 N L3 N QS QS Upper water pool S0 S1 E4 E5 E1 S0 S1 S2 E1 AC380V AC220V AC380V Ta Tc Tb E3 E2 Ta Tc Tb E3 E2 KM KM KM Lower water pool KM M Note: In NJYW1-BL1 or NJYW1-BL2, Ta,Tc,Tb are not one group of changeover contacts, among which Ta & Tc are one group of independent normally open contacts; Tc & Tb are one group of normally closed contacts M 5. Overall and mounting dimensions (mm) Profile and installation dimensions for NJYW1-NL1, NJYW1-NL2, NJYW1-BL1, and NJYW1-BL2 Note: NJYW1-BL1 & NJYW1-BL2 can be used as water supply or water drainage control independently, its wiring diagram referring to NJYW1-NL1. 5 70.5max 115max 60.2±0.37 45.5max 35.4±0.28 > >> I-98 I