2 1 3 4 6 5 7 Client: اﻟﺸﺮآﺔ ﺎ ﻜﻌﻮدﻳﺔﺎء ﻜﻬﺮﺑﺎء Saudi Electricity Company 31-SDMS-02, Rev. 01 DATE: 6-04-2004G SEC DISTRIBUTION MATERIALS SPECIFICATION F اﻟﺸﺮآﺔ ﺎ ﻜﻌﻮدﻳﺔﺎء ﻜﻬﺮﺑﺎء Saudi Electricity Company 31-SDMS-02, Rev. 01 DATE: 6-04-2004G SEC DISTRIBUTION MATERIALS SPECIFICATION اﻟﺸﺮآﺔ ﺎ ﻜﻌﻮدﻳﺔﺎء ﻜﻬﺮﺑﺎء Saudi Electricity Company SEC DISTRIBUTION MATERIALS SPECIFICATION اﻟﺸﺮآﺔ ﺎ ﻜﻌﻮدﻳﺔﺎء ﻜﻬﺮﺑﺎء Saudi Electricity Company 31-SDMS-02, Rev. 01 DATE: 6-04-2004G 31-SDMS-02, Rev. 01 DATE: 6-04-2004G SEC DISTRIBUTION MATERIALS SPECIFICATION اﻟﺸﺮآﺔ ﺎ ﻜﻌﻮدﻳﺔﺎء ﻜﻬﺮﺑﺎء Saudi Electricity Company SEC DISTRIBUTION MATERIALS SPECIFICATION 31-SDMS-02, Rev. 01 DATE: 6-04-2004G F Project Name / Logo: Qiddiya Public Golf Development Public Golf Course E E ±30 ±30 ±30 ±30 ±30 ±30 Notes: ±30 ±30 1. ALL ELECTRICAL SUBSTATIONS, PANELS, FEEDER PILLARS, CABLE LAYING, UNDERGROUND PROTECTION AND DUCT PROVISIONS SHALL BE AS PER LATEST SEC STANDARDS. ±30 ±30 ±30 ±30 ±30 LOW VOLTAGE DISTRIBUTION PILLAR (INTERNAL DETAILS) LOW VOLTAGE DISTRIBUTION PILLAR ±30 LOW VOLTAGE DISTRIBUTION PILLAR LOW VOLTAGE DISTRIBUTION PILLAR ±30 ±30 ±30 ±30 ±30 ±30 LOW VOLTAGE DISTRIBUTION PILLAR BASE DRAWING NO. SEC/DP-02 DRAWING NO. SEC/DP-01 DRAWING NO. SEC/DP-04 DRAWING NO. SEC/DP-03 DRAWING NO. SEC/DP-05 D D TYPICAL DISTRIBUTION PILLAR DETAILS PROPOSED 3nos. x Ø150mm uPVC LV CONDUITS UNDER BRIDGE DECK WITH CABLE HANGER/SUPPORT BRACKET AT EVERY 1m INTERVAL (TYPICAL) WADI/ROAD TOP SURFACE VARIES AS PER SITE CONDITION WADI/ROAD TOP SURFACE VARIES AS PER SITE CONDITION ROAD LEVEL ROAD LEVEL LV CABLES IN CONDUIT (TYPICAL) 500 150 200 150 C PE SHEET OR TANKING Ø200mm PVC PIPE (TYPICAL) CONCRETE ENCASE LEAN CONCRETE COMPACTED SOIL 150 200 100 200 100 200 100 200 150 1400 950 (MIN.) BACKFILL MATERIAL BACKFILL MATERIAL 800 150 200 100 200 150 950 (MIN.) PROPOSED LV CABLE CONDUIT AT BRIDGE SECTIONAL DETAIL C PE SHEET OR TANKING 00 Ø200mm PVC PIPE (TYPICAL) LV CABLES DIRECT BURIED (TYPICAL) CONCRETE ENCASE PROPOSED 8-WAYS Ø200mm PVC DUCT (4nos. X 2-LAYERS) Drawn PROPOSED LV CABLE CONDUIT AT BRIDGE ELEVATION DETAIL NS 30.06.2022 Chk'd Date CONSTRUCTION DRAWINGS Consultant / Lead Designer: PROPOSED 3nos. x Ø150mm uPVC LV CONDUITS UNDER BRIDGE DECK WITH CABLE HANGER/SUPPORT BRACKET AT EVERY 1m INTERVAL (TYPICAL) 150 200 100 200 100 200 100 200 150 1400 RG Description Rev. No. LEAN CONCRETE COMPACTED SOIL PROPOSED 4-WAYS Ø200mm PVC DUCT (4nos. X 1-LAYER) ISSUED FOR CONSTRUCTION Riyadh, 11595 P.O. Box 62621, Saudi Arabia Tel: +966 11 201 2042, Fax: +966 11 201 1023 web: http://www.keoic.com email: info@keoic.com TYPICAL BRIDGELV CABLE CONDUIT DETAILS TYPICAL ROAD/WADI CROSSING DUCT SECTIONS Contractor FINISH GROUND LEVEL FINISH GROUND LEVEL CARTPATH/ACCESS ROAD (TYPICAL) B B LV CABLE DIRECT BURIED (TYPICAL) WADI FINISH GRADING/EMBANKMENT MV/LV CABLES DIRECT BURIED (TYPICAL) WADI PROPOSED LV DUCT (VARIES AS PER REQUIREMENTS) (TYPICAL) Sub-Consultant/Sub-Contractor: MV CABLE DIRECT BURIED (TYPICAL) Drawing Title: 1000 to 1500 1m TO 1.5m MINIMUM CLEARANCE FROM BOTTOM OF WADI TO TOP OF CONCRETE ENCASE DUCT PROPOSED MV DUCT 4/8-WAYS (4 x 2-LAYERS x Ø200mm uPVC) (TYPICAL) FOC CABLE IN Ø100mm DUCT (INDICATIVE ONLY) ELECTRICAL STANDARD DETAILS PROPOSED MV/LV DUCT 4/8-WAYS CONCRETE ENCASE - INSITU (TYPICAL) Reference File: ALL CONDUITS USED SHALL BE SEALED WITH APPROVED MATERIAL AND SPARES CONDUITS SHALL BE PROVIDED WITH END CAP A QD0400-KEO-DRW-DTL-ELE-02-2B1-04501 ALL CONDUITS USED SHALL BE SEALED WITH APPROVED MATERIAL AND SPARES CONDUITS SHALL BE PROVIDED WITH END CAP Checked By: A N. SILVA TYPICAL WADI CROSSING DUCT ELEVATION DETAIL TYPICAL CARTPATH/ACCESS ROAD CROSSING DUCT PLAN Approved By: A. HASSAN Scale: Drawing Number: 1 2 3 4 5 6 7 NTS @ A0 Project ID Orig. Doc. Type. Dwg. Type Disc Area Venue QD0400 KEO DRW DTL ELE 02 2B1 04501 Seq.