Department of Computer Science and Engineering Question Bank Course title Course type Course code Teaching Hours/Week (L:T:P) Credits Internet of Things(IoT) Core 20AD603 CIE Marks (3:0:0) SEE Marks Exam Hours 50 50 03 Course Outcomes: CO1: CO2: CO3: CO4: CO5: To understand and learn Industrial IoT basics, I-IoT data flow, Industrial Protocols and apply the knowledge of IoT. (Understanding, Application) To develop I-IoT data flow. (Synthesis) To learn I-IoT platform and Architecture and implement custom platforms (Comprehension, Application) To gain practical knowledge by using I-IoT Analytics (Synthesis) To analyse the latest IoT techniques used in Industry- to carry out the industrial case study prepare a technical document and make a presentation (Analysis, Syntheses and Evaluation) Q.No UNIT-1 1. 1Discuss the technology enabling factor that have led . to the evolution of IoT eco systems 2. 2Analyse . i) Similarities between IoT and I-IoT ii) Difference between IoT and I-IoT 3. 3With suitable diagram, demonstrate CIM pyramid . 4. 4IoT is not just a specific technological innovation, but radical change that will impact the whole human society. Justify 5. 5Differentiate between i) Sensors and Actuators ii) Continuous Process and Discrete Process 6. 6With suitable diagram, explain I-IoT data flow in a factory 7. 7Illustrate elements of an automated industrial system with neat diagram 8. 8Discuss control and measurement systems illustrating communication network functionalities, device and resources 9. 9Analyze Industrial process classification with suitable diagram Marks 6 BL 1 CO 1 PO 1 PSO 3 6 1 1 2 3 6 3 1 2 3 6 1 1 1 3 6 2 1 2 3 8 3 1 2 3 6 2 1 1 3 5 2 1 2 3 6 4 1 2 3 10. 11. 12. 13. 14. 15. 16. 17. 18. 19. 20. 21. 22. 23. 24. 25. 26. 27. 28. 29. 30. 31. 32. Q.No 1With suitable diagram, demonstrate CIM pyramid 0 1Analyze how a typical automation architecture is 1represented with reference to CIM pyramid using devices and networks 1With regard to CIM pyramid, illustrate Level 1 , 2Level 2 and Level 3-5 networks 1With neat diagram, illustrate IIoT data flow from 3sensors to the cloud 1Discuss the following: 4i) Edge device ii) Industrial IIoT data flow in the cloud 1List and explain the types of networks with regard to 5the CIM pyramid 1Define OPC. Brief the functionalities of OPC 6 With suitable diagram, Analyse I-IoT devices and protocols in factory Outline the measurement and actuator chain to generate control signals with suitable diagram Explain the characteristics of sensor in detail Explain the characteristics of actuator in detail. Illustrate the last control operation. Differentiate between micro controllers and micro processor Illustrate the usage and features of a microcontroller Discuss the following i) DCS ii) PLCs Differentiate between DCS and PLCs Derive the EPA model from OSI model and explain in detail with suitable diagram Analyze the complexity and functionalities of field bus layers and protocols used in the field network What is SCADA. Explain the characteristics of SCADA What is Historian. Explain the characteristics of Historian Discuss the following i) ERP ii) MES What is asset model? Demonstrate S95/S88 model with suitable diagram Describe the equipment entities and relationships in ISA 95 model. Outline the usage of asset model in an LNG company with the equipment hierarchy of S88 standard UNIT-2 6 2 1 2 3 8 4 1 2 3 8 2 1 2 3 5 2 1 2 3 6 2 1 2 3 6 1 1 1 3 6 1 1 1 3 6 2 1 2 3 8 8 2 2 1 1 2 2 3 3 6 2 1 2 3 6 8 2 2 1 1 2 2 3 3 6 8 2 2 1 1 2 2 3 3 6 2 1 2 3 8 2 1 2 3 8 2 1 2 3 6 2 1 2 3 8 2 1 2 3 6 2 1 2 3 6 2 1 2 3 Marks BL CO PO 3 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. 14. 15. 16. 17. 18. 19. 20. 21. 22. 23. 24. 25. 26. With suitable diagram demonstrate OPC layering of OPC Classic Analyze how OPC UA security model is implemented though secure channel Answer the following: i. Advantages and Disadvantages of PLC ii. Advantages and Disadvantages of SCADA With suitable diagram demonstrate OPC UA stack model and information model Synthesize macro components of I-IoT edge and Develop I-IoT edge architecture with suitable diagrams Answer the following: i. Advantages and Disadvantages of DCS ii. Advantages and Disadvantages of Historians Outline the limitations of OPC Classic Illustrate the implementation of data retrieval using both COM and DCOM interface What are the aims of OPC classic standard. Explain how OPC classic works in detail What are the aims of OPC UA standard. Explain how OPC UA works in detail Explain the OPC UA Security model. Give OPC security layer representation with suitable diagram Analyze how the data is retrieved in OPC Classic Develop sequence diagram to establish a connection between OPC UA client and OPC UA Server Demonstrate I-IoT Edge Architecture with neat diagram Analyze strength and weakness of edge on OPC Classic With neat diagram illustrate OPC UA on controller Mention the advantages and disadvantages of SCADA Analyze strength and weakness of edge on OPC UA With neat diagram illustrate Edge on OPC Proxy Mention the advantages and disadvantages of Historian Analyze strength and weakness of edge on field bus set up Mention the advantages and disadvantages of DCS Analyze strength and weakness of edge on OPC DCOM Outline OPC UA notification mechanism with suitable diagram Illustrate the macro components of the edge with neat diagram Describe the important features of edge device in detail 6 2 2 2 3 8 4 2 2 3 6 3 2 2 3 8 2 2 2 3 8 4 2 2 3 6 3 2 2 3 6 8 4 3 2 2 2 2 3 3 8 2 2 2 3 8 2 2 2 3 8 2 2 2 3 6 8 4 3 2 2 2 2 3 3 8 2 2 2 3 6 4 2 2 3 6 6 2 2 2 2 2 2 3 3 6 6 6 4 2 2 2 2 2 2 2 2 3 3 3 6 4 2 2 3 6 6 2 4 2 2 2 2 3 3 6 3 2 2 3 6 3 2 2 3 6 2 2 2 3 27. Differentiate between i) IoT edge and I-IoT edge ii) Fog vs I-IoT edge 28. List and explain edge internet protocols 29. Why it is not possible to connect all the signals to cloud. Give the reasons 30. Represent I-IoT data flow schema used in I-IoT devices and protocols with neat diagram 31. With neat diagram illustrate Edge on OPC UA 32. With neat diagram illustrate Edge on OPC DCOM 33. With neat diagram illustrate Edge on fieldbus Q.No UNIT-3 1. 1Differentiate between ERP or e-commerce data model and IoT asset model 2. 2Compare monolith, OSGi and microservices with appropriate diagram 3. 3What is microservice? Demonstrate its important features in detail 4. 4What is docker? Demonstrate its usage in detail 5. 5List and explain different types of cloud orchestrators 6. 6Illustrate end to end data flow on the I-IoT with suitable diagram 7. 7Discuss cloud based TSDBs with any one example 8. 8Demonstrate asset registry and asset structure with suitable example and diagram 9. 9List I-IoT analytics classifications. Compare them 10. 1Analyze how EMAs are useful in analytics 0 11. 1Analyze Monolithic, OSGI and microlithic services 1with suitable diagrams 12. 1Elaborate end to end flow of I-IoT data on the client 2side with suitable diagram 13. 1Demonstrate Kafka architecture with help of diagram 3 14. 1Analyze ERP Data model and IoT asset model with 4suitable diagrams 15. 1What is asset registry? Illustrate with suitable 5diagram an asset structure using asset hierarchy example 16. 1Demonstrate how time series data is stored on 6Apache Cassandra 17. Illustrate how mosquitto used as MQTT data broker with suitable commands 18. Demonstrate how Apache Kafka is used as a data dispatcher 19. Illustrate how time series data is stored on Apache Cassandra 6 2 2 2 3 6 6 1 2 2 2 2 2 3 3 6 2 2 2 3 6 6 6 2 2 2 2 2 2 2 2 2 3 3 3 Marks 4 BL 2 CO 3 PO 3 3 6 2 3 3 3 6 1 3 3 3 6 6 8 2 2 3 3 3 3 3 3 3 3 3 3 6 6 3 3 3 3 3 3 3 3 6 6 2 4 3 3 3 3 3 3 4 4 3 3 3 6 3 3 3 3 8 3 3 3 3 6 4 3 3 3 6 2 3 3 3 8 2 3 3 3 6 3 3 3 3 6 4 3 3 3 8 4 3 3 3 20. Demonstrate steps to build asset registry to store asset information Discuss pros and cons of the development platform of I-IoT 8 4 3 3 3 6 2 3 3 3 UNIT- 4 Outline the concept of I-IoT analytics in detail Explain different classes of analytics in detail Analyze how descriptive analytics is useful. Mention and explain the techniques Analyze how diagnostics analytics is useful. Mention and explain the techniques Analyze how Predictive analytics is useful. Mention and explain the techniques Analyze how Prescriptive analytics is useful. Mention and explain the techniques Illustrate the scope of CBM in prescriptive analytics Demonstrate technologies related to I-IoT analytics Demonstrate Analytics development workflow with suitable diagram Analyze how data is affected by issues and its impact in the data analytics Illustrate different methods of triggering analytics Illustrate batch and streaming analytics in detail with suitable diagram Explain different classes of I-IoT Analytics Demonstrate Analytics development workflow based on Exploratory Data Analysis Differentiate between Marks 8 8 6 BL 1 2 4 CO 4 4 4 PO 3 3 3 3 3 3 6 4 4 3 3 6 4 4 3 3 6 4 4 3 3 6 8 8 2 2 2 4 4 4 3 3 3 3 3 3 6 4 4 3 3 6 6 2 2 4 3 3 3 6 8 1 3 4 4 3 3 3 3 8 4 4 3 3 6 8 2 4 4 4 3 3 3 3 8 4 4 3 3 Condition based analysis and interactive analysis ii) Data driven model and physics-based model 19. Demonstrate anomaly detection algorithm with ML 8 3 4 3 3 BL CO PO PSO 21. Q.No 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. 14. 15. i) ii) Stream analysis and Batch Analysis Analytics on the cloud and Analytics on the edge 16. Explain I-IoT analytics technologies in detail 17. Demonstrate Open System Architecture and analyze how it is applied to the I-IoT 18. Differentiate between i) Q.No UNIT- 5 Marks 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. 14. 15. 16. 17. 18. 19. Illustrate Industrial automation and control systems reference model with suitable diagram Demonstrate CPwE reference model with suitable diagram Discuss the importance of CPwE Resilient network design What is REP? Illustrate REP notification mechanism and Reconvergence in detail Outline factory wireless LAN architecture with suitable diagram, Analyze Industrial automation control protocols Analyse how securities are applied in connected factories Demonstrate edge computing in the connected factory Illustrate Profinet bus protocol in detail Demonstrate NAT scheme in detail Outline the traditional methods of power generation stages in power utility networks Discuss any 6 tiers of grid block reference architecture Illustrate primary substation grid block in detail Demonstrate traditional SCADA substation network with serial attached RTUs with suitable diagram Analyze IEC 61850 model with suitable diagram Explain network resiliency protocols in the substation with suitable diagram Discuss substation WAN in detail Illustrate Field Area Network grid block with suitable diagram Discuss smart grid security considerations Blooms Level Description L1: Remembering L2: Understanding L3: Applying L4: Analysing L5: Evaluate L6: Create 8 2 5 3 3 8 2 5 3 3 6 2 5 3 3 6 2 5 3 3 8 2 5 3 3 8 6 4 4 5 5 3 3 3 3 8 2 5 3 3 6 6 6 2 2 2 5 5 5 3 3 3 3 3 3 6 2 5 3 3 8 8 2 2 5 5 3 3 3 3 8 8 4 2 5 5 3 3 3 3 8 8 2 2 5 5 3 3 3 3 6 2 5 3 3 Marks