TECHNICAL DATA SHEET
Contact
QICC-Nexans
Phone: +97444085100
Email: sales.qatar@nexans.com
3x6 Cu/XLPE/SWA/HFFR 0.6/1/1.2 kV IEC color code/BS 6724
DESCRIPTION
600/1000V XLPE Steel wire armoured, three core cables with copper conductor
23006SXZHSH30BS0
IEC color code/BS 6724
IEC 60332-3-24 Cat C
Drawings colors and dimensions
are for demonstration purposes only
APPLICATION
Power use outdoor application,
Suitable for fixed installations at open air, in tube or canals and underground
Max. Operation temperature: 90°
Max. Short circuit temperature : 250° (Max 5 s)
CONSTRUCTION
1. Conductor:
Round conductor class 2
2. Insulation:
Insulation Type XLPE
3. Metallic screen layer:
None
4. Insulating Colour Sequence:
Red - Yellow - Blue
5. Bedding:
HFFR bedding layer "Natural OR Black".
6. Lead Sheathing:
None.
Technical Data Sheet
Form no. TEC091F_01
Issue Date: 02-Jan-2020
TECHNICAL DATA SHEET
Contact
QICC-Nexans
Phone: +97444085100
Email: sales.qatar@nexans.com
7. Separation Sheathing:
None.
8. Armour:
Galvanized steel wire armour
9. Outer sheath:
HFFR -, outer sheath.
10. Outer sheath colour:
Black
11. Marking: (by Engraving or Ink)
3 x 6 mm2 Cu / XLPE / SWA/ HFFR 600/1000 V BS 6724
MADE IN QATAR QICC-Nexans Year Meters
12. Packing:
All drum types, lagged or not, up to a diameter of 3.0 m and a total weight of 13 tons. Drums can be wooden or steel.
The length per drum as per customer requirement.
Approximate drum size will be: As per the Standard Estimated Packing List.
CHARACTERISTICS
Construction characteristics
Conductor flexibility
Conductor shape
Material used for length water tightness
Insulating Material
Nominal Insulation Thickness
Min @ Point
Screen
Material of bedding / filling
Approximate Thickness
Armour Type
Armour Wire Diameter/Tape Thickness
Outer sheath
Nominal Thickness
Min @ Point
Outer sheathing colour
Outer sheathing diameter (Approx.)
Length per drum
Electrical characteristics
Rated Voltage Uo/U (Um)
Frequency
Test voltage
DC Resistance @ 20°C
AC Resistance @ 90°C
Short Circuit Current of Conductor
Approx. capacitance
Technical Data Sheet
Form no. TEC091F_01
Stranded class 2
Round
None
XLPE
0.7mm
0.53mm
None
HFFR
0.8mm
SWA
0.9mm
HFFR 1.4mm
0.92mm
Black or as per customer requirement
15.3mm
As per the Standard Estimated Packing
List
Voltage range 600/1000V
50Hz
3.5kV
3.08 Ohm
3.92731 Ohm
0.858 KA
0.339 µF/KM
Issue Date: 02-Jan-2020
TECHNICAL DATA SHEET
Current Carry Capacity:
Current Carry Capacity in Air (Shaded)
Current Carry Capacity in Ground
Current Carry Capacity in Ground Duct
Installation Condition:
Air temperature (Deg)
Ground temperature (Deg)
Depth of lay (m)
Soil thermal resistivity (K.m/W)
Mechanical characteristics
Mechanical resistance to impacts
Cable flexibility
Approx. Bending radius
Approx. Max pulling force
Usage characteristics
Short-circuit max. conductor temperature
Max. conductor temperature in service
Technical Data Sheet
Form no. TEC091F_01
Contact
QICC-Nexans
Phone: +97444085100
Email: sales.qatar@nexans.com
56A
49A
44A
30
20
0.7
2.5
Good
Rigid
190mm
0.9 KN
250°C
90°C
Issue Date: 02-Jan-2020
Download