TECHNICAL DATA SHEET Contact QICC-Nexans Phone: +97444085100 Email: sales.qatar@nexans.com 3x6 Cu/XLPE/SWA/HFFR 0.6/1/1.2 kV IEC color code/BS 6724 DESCRIPTION 600/1000V XLPE Steel wire armoured, three core cables with copper conductor 23006SXZHSH30BS0 IEC color code/BS 6724 IEC 60332-3-24 Cat C Drawings colors and dimensions are for demonstration purposes only APPLICATION Power use outdoor application, Suitable for fixed installations at open air, in tube or canals and underground Max. Operation temperature: 90° Max. Short circuit temperature : 250° (Max 5 s) CONSTRUCTION 1. Conductor: Round conductor class 2 2. Insulation: Insulation Type XLPE 3. Metallic screen layer: None 4. Insulating Colour Sequence: Red - Yellow - Blue 5. Bedding: HFFR bedding layer "Natural OR Black". 6. Lead Sheathing: None. Technical Data Sheet Form no. TEC091F_01 Issue Date: 02-Jan-2020 TECHNICAL DATA SHEET Contact QICC-Nexans Phone: +97444085100 Email: sales.qatar@nexans.com 7. Separation Sheathing: None. 8. Armour: Galvanized steel wire armour 9. Outer sheath: HFFR -, outer sheath. 10. Outer sheath colour: Black 11. Marking: (by Engraving or Ink) 3 x 6 mm2 Cu / XLPE / SWA/ HFFR 600/1000 V BS 6724 MADE IN QATAR QICC-Nexans Year Meters 12. Packing: All drum types, lagged or not, up to a diameter of 3.0 m and a total weight of 13 tons. Drums can be wooden or steel. The length per drum as per customer requirement. Approximate drum size will be: As per the Standard Estimated Packing List. CHARACTERISTICS Construction characteristics Conductor flexibility Conductor shape Material used for length water tightness Insulating Material Nominal Insulation Thickness Min @ Point Screen Material of bedding / filling Approximate Thickness Armour Type Armour Wire Diameter/Tape Thickness Outer sheath Nominal Thickness Min @ Point Outer sheathing colour Outer sheathing diameter (Approx.) Length per drum Electrical characteristics Rated Voltage Uo/U (Um) Frequency Test voltage DC Resistance @ 20°C AC Resistance @ 90°C Short Circuit Current of Conductor Approx. capacitance Technical Data Sheet Form no. TEC091F_01 Stranded class 2 Round None XLPE 0.7mm 0.53mm None HFFR 0.8mm SWA 0.9mm HFFR 1.4mm 0.92mm Black or as per customer requirement 15.3mm As per the Standard Estimated Packing List Voltage range 600/1000V 50Hz 3.5kV 3.08 Ohm 3.92731 Ohm 0.858 KA 0.339 µF/KM Issue Date: 02-Jan-2020 TECHNICAL DATA SHEET Current Carry Capacity: Current Carry Capacity in Air (Shaded) Current Carry Capacity in Ground Current Carry Capacity in Ground Duct Installation Condition: Air temperature (Deg) Ground temperature (Deg) Depth of lay (m) Soil thermal resistivity (K.m/W) Mechanical characteristics Mechanical resistance to impacts Cable flexibility Approx. Bending radius Approx. Max pulling force Usage characteristics Short-circuit max. conductor temperature Max. conductor temperature in service Technical Data Sheet Form no. TEC091F_01 Contact QICC-Nexans Phone: +97444085100 Email: sales.qatar@nexans.com 56A 49A 44A 30 20 0.7 2.5 Good Rigid 190mm 0.9 KN 250°C 90°C Issue Date: 02-Jan-2020