Specifications for the CARESTREAM DRX Plus Detectors Important • Qualified service personnel must perform these procedures. • See the Carestream Service Portal for possible updates before you begin. • When doing the procedures in this document, you must use safe work practices and wear the correct personal protective equipment (for example, safety eyewear) according to your company’s standard operating procedures. • When servicing this equipment, be sure to read and follow the Manufacturer’s Safety Data Sheets for any chemical, cleaner, solvent, paint, lubricant, adhesive, or replacement battery to understand proper use and disposal precautions. Confidential Publication No. AC3451 2016-04-29 Supersedes: 2016-02-10 All rights reserved. No part of this manual may be reproduced or copied in any form by any mean graphic, electronic, or mechanical, including photocopying, typing, or information retrieval systems without written permission. 1 DRX Plus 3543 Detector Detector Imaging Specifications Detector Type Amorphous Silicon on glass—no tiling Conversion Screen Attached Gd202 S:Tb Pixel Size (μm) Resolution Limit (cyc/mm) 139 x 139 3.6 Usable Pixel Area (cm) (inch) (pixels) 35.4 x 42.5 14 x 16.7 2544 x 3056 MTF (%) 0.056 cyc/mm, Typical 0.5 cyc/mm, Typical 1.0 cyc/mm, Typical 1.5 cyc/mm, Typical 2.0 cyc/mm, Typical 2.5 cyc/mm, Typical 3.0 cyc/mm, Typical 3.5 cyc/mm, Typical DQE (%) ±2 sigma < 10 % IEC 62220-1-1 Edition 1.0, 2015 0.056 cyc/mm, Typical 0.5 cyc/mm, Typical 1.0 cyc/mm, Typical 1.5 cyc/mm, Typical 2.0 cyc/mm, Typical 2.5 cyc/mm, Typical 3.0 cyc/mm, Typical 3.5 cyc/mm, Typical Energy Range AC3451 | 2016-04-29 RQA-3 Beam RQA-5 Beam 99 83 61 42 28 19 13 10 98 79 54 36 23 16 10 7 RQA-3 Beam RQA-5 Beam 0.97 μGy 3.1 μGy 9.92 μGy 0.97 μGy 3.1 μGy 9.92 μGy 35 32 27 21 14 9 5 3 38 34 30 25 19 13 8 5 37 34 30 25 20 15 10 6 34 30 25 18 13 9 5 3 35 31 25 20 15 10 7 4 35 30 25 20 15 11 7 4 40–150 kVp 1–1 DRX Plus 3543 Detector Imaging Specifications Scan Method Progressive A/D Conversion 16 bits Supported Data Interfaces Wireless 802.11 A, or N, or G Tethered 10/100/1000 Ethernet Environmental Shock High shock tolerance Temperature Range Operating +15 to +30° C (+59 to +86° F) Ambient storage and shipping -10 to +66° C (+14 to +150° F) Relative Humidity, Non-Condensing Operating 10 to 86 % Storage 10 to 86 % Ingress Protection IP57 Mechanical Size (cm) 35 x 43 Cassette (ISO 4090) 38.35 x 45.95 x 1.47 cm Weight 3.06 kg (6.75 lb) Housing Material Aluminum Sensor Protection Material Carbon fiber and aluminum plate Load Limit Applied to a single 4 cm (1.6 in.) point: 114 kg (250 lb) Distributed evenly over the detector area: 170 kg (375 lb) Detector Battery Technology Size 1–2 • Lithium-polymer Technology • “Smart” battery technology prevents overcharge 21.0 x 15.0 x 0.67 cm AC3451 | 2016-04-29 DRX Plus 3543 Detector Detector Battery Weight 0.4 kg (12.4 oz.) Voltage / Energy 14.6 to 14.8V DC, 2.1 to 2.5Ah capacity Battery "Hot Swap" Capability Yes Charge Capability • 340 maximum images per charge in Direct Connect Mode. • 14 days per charge in undisturbed Sleep Mode. Expected Life 500 charge / discharge cycles results in ~80% full charge energy Medical Safety IEC 62133 —Safety requirements for secondary cells and batteries containing alkaline or other non-acid electrolytes Electromagnetic Compatibility IEC 60601-1-2 Ed. 2.1-Medical Electrical Equipment Electromagnetic Compatibility Requirements and tests, including CISPR 11:1999 + A2:02 emissions Group 1, Class A) Wireless System Technical Specifications Network Protocol TCP/IP, IPv4, IPv6 Network Type Isolated private wireless LAN (WLAN) Wireless Protocol 802.11 A, or N, or G Antenna: Frequency Band 5 and 2.4 GHz Available Channels (fixed at installation) 1, 5, 9, 13, 36, 40, 44, 48, 52, 56, 60, 64, 100, 104, 108, 112, 116, 120, 124, 128, 132, 136, 140, 149, 153, 157, 161, and 165 Maximum Power of Detector Radio 50 mW Number of Antennas on Detector 2 IP Addressing Static private IP addresses for detectors and access point (AP) Agency approvals FCC Part 15 Typical Data Size One 15 MB file per image Dual Homed PC (two NIC cards) Hospital network connection, private network connection AC3451 | 2016-04-29 1–3 DRX Plus 3543 Detector Security WPA2-PSK AES Factory and user loaded keys SSID Broadcast Private Patient Identification Data No patient ID data exchanged with detector User name and Password Non-default user name and password Enterprise Wireless IP Addressing Static or DHCP Authentication The detector supports authentication with most radius servers using the following protocols: EAP-TLS, EAP-PEAP-MSCHAPV2, EAP-FAST, EAP-PEAP-TLS, EAP-TTLS, EAP-TTLS-MSCHAPV2 Encryption Methods AES-CCMP, WPA2-AES Certificates supported .pern, .crt, .cer, .der, .p7b, .pfx, .p12 extensions Keys Private keys with .key extensions QOS Control signals and data path can be separately configured. 1–4 AC3451 | 2016-04-29 2 DRX Plus 3543C Detector Detector Imaging Specifications Detector Type Amorphous Silicon on glass—no tiling Conversion Screen Deposited CsI (TI) Pixel Size (μm) Resolution Limit (cyc/mm) 139 x 139 3.6 Usable Pixel Area (cm) (inch) (pixels) 35.0 x 42.3 13.8 x 16.6 2520 x 3032 MTF (%) RQA-3 Beam RQA-5 Beam 99 82 59 41 29 21 15 11 99 83 61 44 32 23 17 13 RQA-3 Beam RQA-5 Beam 0.05 cyc/mm, Typical 0.5 cyc/mm, Typical 1.0 cyc/mm, Typical 1.5 cyc/mm, Typical 2.0 cyc/mm, Typical 2.5 cyc/mm, Typical 3.0 cyc/mm, Typical 3.5 cyc/mm, Typical DQE (%) ±2 sigma < 10 % 0.056 cyc/mm, Typical 0.5 cyc/mm, Typical 1.0 cyc/mm, Typical 1.5 cyc/mm, Typical 2.0 cyc/mm, Typical 2.5 cyc/mm, Typical 3.0 cyc/mm, Typical 3.5 cyc/mm, Typical Energy Range (kVp) AC3451 | 2016-04-29 0.78 μGy 2.5 μGy 8.0 μGy 0.78 μGy 2.5 μGy 8.0 μGy 70 63 50 41 32 23 16 10 72 65 54 45 37 30 21 13 72 63 53 45 38 32 23 15 70 64 55 48 40 32 24 16 70 63 56 50 44 36 28 18 67 61 53 48 42 35 28 18 40–150 2–1 DRX Plus 3543C Detector Imaging Specifications Scan Method Progressive A/D Conversion (bits) 16 Supported Data Interfaces Wireless 802.11 A, or N, or G Tethered 10/100/1000 Ethernet Environmental Shock High shock tolerance Temperature Range Operating +15 to +30° C (+59 to +86° F) Ambient storage and shipping -10 to +66° C (+14 to +150° F) Relative Humidity, Non-Condensing % Operating 10 to 86 Storage 10 to 86 Ingress Protection IP57 Mechanical Size (cm) 35 x 43 Cassette (ISO 4090) 38.35 x 45.95 x 1.47 cm Weight 3.17 kg (6.99 lb) Housing Material Aluminum Sensor Protection Material Carbon fiber and aluminum plate Weight Limit Applied to a single 4 cm (1.6 in.) point: 114 kg (250 lb) Distributed evenly over the detector area: 170 kg (375 lb) Detector Battery Technology Size 2–2 • Lithium-polymer Technology • “Smart” battery technology prevents overcharge 21 x 15 x 0.67 cm AC3451 | 2016-04-29 DRX Plus 3543C Detector Detector Battery Weight 0.4 kg (12.4 oz.) Voltage / Energy 14.6 to 14.8V DC, 2.1 to 2.5Ah capacity Battery "Hot Swap" Capability Yes Charge Capability • 340 maximum images per charge in Direct Connect Mode. • 14 days per charge in undisturbed Sleep Mode. Expected Life 500 charge / discharge cycles results in ~80% full charge energy Medical Safety IEC 62133 -Safety requirements for secondary cells andbatteries containing alkaline or other non-acid electrolytes Electromagnetic Compatibility IEC 60601-1-2 Ed. 2.1, 2004-Medical Electrical Equipment Electromagnetic Compatibility Requirements and tests, including CISPR 11:1999 + A2:02 emissions Group 1, Class A) Wireless System Technical Specifications Network Protocol TCP/IP, IPv4/IPv6 Network Type Isolated private wireless LAN (WLAN) Enterprise Wireless Wireless Protocol 802.11 A, or N, or G Antenna:Frequency Band Available Channels (fixed at installation) 5 and 2.4 GHz 1, 5, 9, 13, 36, 40, 44, 48, 52, 56, 60, 64, 100, 104, 108, 112, 116, 120, 124, 128, 132, 136, 140, 149, 153, 157, 161, and 165 Maximum Power of Detector Radio 50 mW Number of Antennas on Detector 2 IP Addressing Static private IP addresses for detectors and access point (AP) Agency approvals FCC Part 15 Typical Data Size One 15 MB file per image Dual Homed PC (two NIC cards) Hospital network connection, private network connection AC3451 | 2016-04-29 2–3 DRX Plus 3543C Detector Security WPA2-PSK AES Factory and user loaded keys SSID Broadcast Private Patient Identification Data No patient ID data exchanged with detector User name and Password Non-default user name and password Enterprise Wireless IP Addressing Static or DHCP Authentication The detector supports authentication with most radius servers using the following protocols: EAP-TLS, EAP-PEAP-MSCHAPV2, EAP-FAST, EAP-PEAP-TLS, EAP-TTLS, EAP-TTLS-MSCHAPV2 Encryption Methods AES-CCMP, WPA2-AES Certificates supported .pern, .crt, .cer, .der, .p7b, .pfx, .p12 extensions Keys Private keys with .key extensions QOS Control signals and data path can be separately configured. 2–4 AC3451 | 2016-04-29 3 DRX Plus 4343 Detector Detector Imaging Specifications Receptor Type Amorphous Silicon on glass—no tiling Conversion Screen Attached Gd202 S:Tb Pixel Size (μm) Resolution Limit (cyc/mm) 139 x 139 3.6 Usable Pixel Area (cm) (inch) (pixels) 42.5 x 42.5 16.7 x 16.7 3056 x 3056 MTF (%) 0.056 cyc/mm, Typical 0.5 cyc/mm, Typical 1.0 cyc/mm, Typical 1.5 cyc/mm, Typical 2.0 cyc/mm, Typical 2.5 cyc/mm, Typical 3.0 cyc/mm, Typical 3.5 cyc/mm, Typical DQE (%) ±2 sigma < 10 % RQA-3 Beam RQA-5 Beam 99 83 61 42 28 19 13 10 98 79 54 36 23 16 10 7 RQA-3 Beam RQA-5 Beam IEC 62220-1-1, Edition 1.0, 2015 0.97 μGy 3.1 μGy 9.92 μGy 0.97 μGy 3.1 μGy 9.92 μGy 0.056 cyc/mm, Typical 0.5 cyc/mm, Typical 1.0 cyc/mm, Typical 1.5 cyc/mm, Typical 2.0 cyc/mm, Typical 2.5 cyc/mm, Typical 3.0 cyc/mm, Typical 3.5 cyc/mm, Typical 35 32 27 21 14 9 5 3 38 34 30 25 19 13 8 5 37 34 30 25 20 15 10 6 34 30 25 18 13 9 5 3 35 31 25 20 15 10 7 4 35 30 25 20 15 11 7 4 Energy Range AC3451 | 2016-04-29 40–150 kVp 3–1 DRX Plus 4343 Detector Imaging Specifications Scan Method Progressive A/D Conversion 16 bits Supported Data Interfaces Wireless 802.11 A, or N, or G Tethered 10/100/1000 Ethernet Environmental Shock High shock tolerance Temperature Range Operating +15 to +30° C (+59 to +86° F) Ambient storage and shipping -10 to +66° C (+14 to +150° F) Relative Humidity, Non-Condensing Operating 10 to 86 % Storage 10 to 86 % Ingress Protection IP57 Mechanical Size (cm) 43 x 43 Cassette (ISO 4090) 45.95 x 45.95 x 1.47 cm Weight 3.63 kg (8.0 lb) Housing Material Aluminum Sensor Protection Material Carbon fiber and aluminum plate Load Limit Applied to a single 4 cm (1.6 in.) point: 114 kg (250 lb) Distributed evenly over the detector area: 170 kg (375 lb) Detector Battery Technology Size 3–2 • Lithium-polymer Technology • “Smart” battery technology prevents overcharge 21.0 x 15.0 x 0.67 cm AC3451 | 2016-04-29 DRX Plus 4343 Detector Detector Battery Weight 0.4 kg (12.4 oz.) Voltage / Energy 14.6 to 14.8V DC, 2.1 to 2.5Ah capacity Battery "Hot Swap" Capability Yes Charge Capability • 340 maximum images per charge in Direct Connect Mode. • 14 days per charge in undisturbed Sleep Mode. Expected Life 500 charge / discharge cycles results in ~80% full charge energy Medical Safety IEC 62133 —Safety requirements for secondary cells andbatteries containing alkaline or other non-acid electrolytes Electromagnetic Compatibility IEC 60601–1–2 Ed. 2.1 —Medical Electrical EquipmentElectromagnetic Compatibility Requirements and tests,including CISPR 11:1999 + A2:02 emissions Group 1, ClassA) Wireless System Technical Specifications Network Protocol TCP/IP, IPv4, IPv6 Network Type Isolated private wireless LAN (WLAN) Enterprise Wireless Wireless Protocol 802.11 A, or N, or G Antenna: Frequency Band 5 and 2.4 GHz Available Channels (fixed at installation) 1, 5, 9, 13, 36, 40, 44, 48, 52, 56, 60, 64, 100, 104, 108, 112, 116, 120, 124, 128, 132, 136, 140, 149, 153, 157, 161, and 165 Maximum Power of Detector Radio 50 mW Number of Antennas on Detector 2 IP Addressing Static private IP addresses for detectors and access point (AP) Agency approvals FCC Part 15 Typical Data Size One 18.5 MB file per image Dual Homed PC (two NIC cards) Hospital network connection, private network connection AC3451 | 2016-04-29 3–3 DRX Plus 4343 Detector Security WPA2-PSK AES Factory and user loaded keys SSID Broadcast Private Patient Identification Data No patient ID data exchanged with detector User name and Password Non-default user name and password Enterprise Wireless IP Addressing Static or DHCP Authentication The detector supports authentication with most radius servers using the following protocols: EAP-TLS, EAP-PEAP-MSCHAPV2, EAP-FAST, EAP-PEAP-TLS, EAP-TTLS, EAP-TTLS-MSCHAPV2 Encryption Methods AES-CCMP, WPA2-AES Certificates supported .pern, .crt, .cer, .der, .p7b, .pfx, .p12 extensions Keys Private keys with .key extensions QOS Control signals and data path can be separately configured. 3–4 AC3451 | 2016-04-29 4 DRX Plus 4343C Detector Detector Imaging Specifications Receptor Type Amorphous Silicon on glass—no tiling Conversion Screen Deposited CsI (Tl) Pixel Size (μm) Resolution Limit (cyc/mm) 139 x 139 3.6 Usable Pixel Area (cm) (inch) (pixels) 42.3 x 42.3 16.6 x 16.6 3032 x 3032 MTF (%) 0.056 cyc/mm, Typical 0.5 cyc/mm, Typical 1.0 cyc/mm, Typical 1.5 cyc/mm, Typical 2.0 cyc/mm, Typical 2.5 cyc/mm, Typical 3.0 cyc/mm, Typical 3.5 cyc/mm, Typical DQE (%) ±2 sigma < 10 % RQA-3 Beam RQA-5 Beam 99 82 59 41 29 21 15 11 99 83 61 44 32 23 17 13 RQA-3 Beam RQA-5 Beam IEC 62220-1-1, Edition 1.0, 2015 0.78 μGy 2.5 μGy 8.0 μGy 0.78 μGy 2.5 μGy 8.0 μGy 0.056 cyc/mm, Typical 0.5 cyc/mm, Typical 1.0 cyc/mm, Typical 1.5 cyc/mm, Typical 2.0 cyc/mm, Typical 2.5 cyc/mm, Typical 3.0 cyc/mm, Typical 3.5 cyc/mm, Typical 70 63 50 41 32 23 16 10 72 65 54 45 37 30 21 13 72 63 53 45 38 32 23 15 70 64 55 48 40 32 24 16 70 63 56 50 44 36 28 18 67 61 53 48 42 35 28 18 Energy Range AC3451 | 2016-04-29 40–150 kVp 4–1 DRX Plus 4343C Detector Imaging Specifications Scan Method Progressive A/D Conversion 16 bits Supported Data Interfaces Wireless 802.11A, or N, or G Tethered 10/100/1000 Ethernet Environmental Shock High shock tolerance Temperature Range Operating +15 to +30° C (+59 to +86° F) Ambient storage and shipping -10 to +66° C (+14 to +150° F) Relative Humidity, Non-Condensing Operating 10 to 86 % Storage 10 to 86 % Ingress Protection IP57 Mechanical Size (cm) 43 x 43 Cassette (ISO 4090) 45.95 x 45.95 x 1.47 cm Weight 3.74 kg (8.25 lb) Housing Material Aluminum Sensor Protection Material Carbon fiber and aluminum plate Load Limit Applied to a single 4 cm (1.6 in.) point: 114 kg (250 lb) Distributed evenly over the detector area: 170 kg (375 lb) Detector Battery Technology Size 4–2 • Lithium-polymer Technology • “Smart” battery technology prevents overcharge 21.0 x 15.0 x 0.67 cm AC3451 | 2016-04-29 DRX Plus 4343C Detector Detector Battery Weight 0.4 kg (12.4 oz.) Voltage / Energy 14.6 to 14.8V DC, 2.1 to 2.5Ah capacity Battery "Hot Swap" Capability Yes Charge Capability • 340 maximum images per charge in Direct Connect Mode. • 14 days per charge in undisturbed Sleep Mode. Expected Life 500 charge / discharge cycles results in ~80% full charge energy Medical Safety IEC 62133:—Safety requirements for secondary cells and batteries containing alkaline or other non-acid electrolytes Electromagnetic Compatibility IEC 60601-1-2 Ed. 2.1, 2004-Medical Electrical Equipment Electromagnetic Compatibility Requirements and tests, including CISPR 11:1999 + A2:02 emissions Group 1, Class A) Wireless System Technical Specifications Network Protocol TCP/IP, IPv4, IPv6 Network Type Isolated private wireless LAN (WLAN) Enterprise Wireless Wireless Protocol 802.11 A, or N, or G Antenna: Frequency Band 5 and 2.4 GHz Available Channels (fixed at installation) 1, 5, 9, 13, 36, 40, 44, 48, 52, 56, 60, 64, 100, 104, 108, 112, 116, 120, 124, 128, 132, 136, 140, 149, 153, 157, 161, and 165 Maximum Power of Detector Radio 50 mW Number of Antennas on Detector 2 IP Addressing Static private IP addresses for detectors and access point (AP) Agency approvals FCC Part 15 Typical Data Size One 18.5 MB file per image Dual Homed PC (two NIC cards) Hospital network connection, private network connection AC3451 | 2016-04-29 4–3 DRX Plus 4343C Detector Security WPA2-PSK AES Factory and user loaded keys SSID Broadcast Private Patient Identification Data No patient ID data exchanged with detector User name and Password Non-default user name and password Enterprise Wireless IP Addressing Static or DHCP Authentication The detector supports authentication with most radius servers using the following protocols: EAP-TLS, EAP-PEAP-MSCHAPV2, EAP-FAST, EAP-PEAP-TLS, EAP-TTLS, EAP-TTLS-MSCHAPV2 Encryption Methods AES-CCMP, WPA2-AES Certificates supported .pern, .crt, .cer, .der, .p7b, .pfx, .p12 extensions Keys Private keys with .key extensions QOS Control signals and data path can be separately configured. 4–4 AC3451 | 2016-04-29 5 DRX Plus 4343F Detector Imaging Specifications Receptor Type Amorphous Silicon on glass—no tiling Conversion Screen Attached Gd202 S:Tb Pixel Size (μm) Resolution Limit (cyc/mm) 139 x 139 3.6 Usable Pixel Area (cm) (inch) (pixels) 42.5 x 42.5 16.7 x 16.7 3056 x 3056 MTF (%) 0.056 cyc/mm, Typical 0.5 cyc/mm, Typical 1.0 cyc/mm, Typical 1.5 cyc/mm, Typical 2.0 cyc/mm, Typical 2.5 cyc/mm, Typical 3.0 cyc/mm, Typical 3.5 cyc/mm, Typical DQE (%) ±2 sigma < 10 % RQA-3 Beam RQA-5 Beam 99 83 61 42 28 19 13 10 98 79 54 36 23 16 10 7 RQA-3 Beam RQA-5 Beam IEC 62220-1-1, Edition 1.0, 2015 0.97 μGy 3.1 μGy 9.92 μGy 0.97 μGy 3.1 μGy 9.92 μGy 0.056 cyc/mm, Typical 0.5 cyc/mm, Typical 1.0 cyc/mm, Typical 1.5 cyc/mm, Typical 2.0 cyc/mm, Typical 2.5 cyc/mm, Typical 3.0 cyc/mm, Typical 3.5 cyc/mm, Typical 35 32 27 21 14 9 5 3 38 34 30 25 19 13 8 5 37 34 30 25 20 15 10 6 34 30 25 18 13 9 5 3 35 31 25 20 15 10 7 4 35 30 25 20 15 11 7 4 Energy Range AC3451 | 2016-04-29 40–150 kVp 5–1 DRX Plus 4343F Detector Imaging Specifications Scan Method Progressive A/D Conversion 16 bits Supported Data Interfaces Tethered 10/100/1000 Ethernet Environmental Shock High shock tolerance Temperature Range Operating +15 to +30° C (+59 to +86° F) Ambient storage and shipping -10 to +66° C (+14 to +150° F) Relative Humidity, Non-Condensing Operating 10 to 86 % Storage 10 to 86 % Ingress Protection IPX0 Mechanical Size (cm) 43 x 43 Cassette (ISO 4090) 45.95 x 45.95 x 1.47 cm Weight 3.53 kg (7.8 lb) Housing Material Aluminum Sensor Protection Material Carbon fiber and aluminum plate Load Limit Applied to a single 4 cm (1.6 in.) point: 114 kg (250 lb) Distributed evenly over the detector area: 170 kg (375 lb) Security Private Patient Identification Data No patient ID data exchanged with detector User name and Password Non-default user name and password 5–2 AC3451 | 2016-04-29 6 DRX Plus 4343FC Detector Imaging Specifications Receptor Type Amorphous Silicon on glass—no tiling Conversion Screen Deposited CsI (Tl) Pixel Size (μm) Resolution Limit (cyc/mm) 139 x 139 3.6 Usable Pixel Area (cm) (inch) (pixels) 42.3 x 42.3 16.6 x 16.6 3032 x 3032 MTF (%) 0.056 cyc/mm, Typical 0.5 cyc/mm, Typical 1.0 cyc/mm, Typical 1.5 cyc/mm, Typical 2.0 cyc/mm, Typical 2.5 cyc/mm, Typical 3.0 cyc/mm, Typical 3.5 cyc/mm, Typical DQE (%) ±2 sigma < 10 % RQA-3 Beam RQA-5 Beam 99 82 59 41 29 21 15 11 99 83 61 44 32 23 17 13 RQA-3 Beam RQA-5 Beam IEC 62220-1-1, Edition 1.0, 2015 0.78 μGy 2.5 μGy 8.0 μGy 0.78 μGy 2.5 μGy 8.0 μGy 0.056 cyc/mm, Typical 0.5 cyc/mm, Typical 1.0 cyc/mm, Typical 1.5 cyc/mm, Typical 2.0 cyc/mm, Typical 2.5 cyc/mm, Typical 3.0 cyc/mm, Typical 3.5 cyc/mm, Typical 70 63 50 41 32 23 16 10 72 65 54 45 37 30 21 13 72 63 53 45 38 32 23 15 70 64 55 48 40 32 24 16 70 63 56 50 44 36 28 18 67 61 53 48 42 35 28 18 Energy Range AC3451 | 2016-04-29 40–150 kVp 6–1 DRX Plus 4343FC Detector Imaging Specifications Scan Method Progressive A/D Conversion 16 bits Supported Data Interfaces Tethered 10/100/1000 Ethernet Environmental Shock High shock tolerance Temperature Range Operating +15 to +30° C (+59 to +86° F) Ambient storage and shipping -10 to +66° C (+14 to +150° F) Relative Humidity, Non-Condensing Operating 10 to 86 % Storage 10 to 86 % Ingress Protection IPX0 Mechanical Size (cm) 43 x 43 Cassette (ISO 4090) 45.95 x 45.95 x 1.47 cm Weight 3.63 kg (8.0 lb) Housing Material Aluminum Sensor Protection Material Carbon fiber and aluminum plate Load Limit Applied to a single 4 cm (1.6 in.) point: 114 kg (250 lb) Distributed evenly over the detector area: 170 kg (375 lb) Security Private Patient Identification Data No patient ID data exchanged with detector User name and Password Non-default user name and password 6–2 AC3451 | 2016-04-29 7 DRX Plus Statements Related to Systems Integration Detector Safety The detector has been approved to IEC 60601-1 by TUV Rheinland and has a cTUVus and CE safety certification as a Medical Electrical Equipment device. Recycling The detector should be returned to Carestream Health at the end of life. The components will be recycled appropriately. The Lithium-polymer battery is WEEE compliant (as shown by the Wheelie Dustbin logo) and should be recycled at local recycling stations. Carestream Health pays taxes in the EU Battery Directive countries to cover the recycling costs. Line Noise Correction The Image Correction Preference is used for the following purpose: • Normal—Reduces correlated line noise due to readout ICs. This is a very subtle correction, limited to near zero signal levels. • Enhanced—Reduces correlated line noise due to external EMI sources, such as motor drives and power supplies. This level should only be used if there is detectable line noise in the images. Grids • Moving Grids: Moving grids should not exhibit grid aliasing. If the exposure time is very short, the grid may alias with any digital detector. This is normally not a problem, since grids are used on large body parts, which generally require exposure times longer than 20 ms. • Low Resolution Stationary Grids: 30-to-50 Lines/cm (76-to-127 Lines/inch) Carestream image processing software will automatically remove the visible lines from the full resolution image. • High Resolution Stationary Grids: ≥ 75 Lines/cm (>191 Lines/inch)—Grid resolutions of 75 Lines/cm or greater will not be visible on images. • Medium Resolution Stationary Grids: 50-to-75 Lines/cm (127-to-191 Lines/inch)—Stationary grids in this range may cause aliasing and are therefore not recommended. However, medium resolution moving grids should not exhibit aliasing. AC3451 | 2016-04-29 7–1 DRX Plus Statements Related to Systems Integration Durability The detector has been designed to be a robust device and function properly in normal handling. The instrument may be damaged if it receives a strong jolt from a drop or strike. The warranty does not cover damage as a result of accident or abuse, including broken detector glass and other obvious damage, however a drop rider can be purchased to protect the investment. The detector has been equipped with internal accelerometers that will register when the detector has incurred a significant shock. The drop height that results in a registered event depends on the orientation of the detector during the drop, and the stiffness of the surface it strikes. Detector Life The detector system is specified to last 10 years under normal use of 56,000 images per year. That is ~560K images. This statement relates to the life of the physical aspects of the product, including hardware, normal physical handling and image acquisition No Preventive Maintenance (PM) is required on the system. Detector Quality Assurance The detector must undergo gain calibration on an annual basis. A 360 day reminder is built into the software. Express Calibration restores Gain Calibration and Defect Calibration and does a defect quality check. Full Calibration is the same as Express Calibration and adds quality checks for Signal Uniformity, Noise Uniformity and Dark Noise Permanent pixel defects are identified in the factory based on outlier performance in dark noise, X-ray uniformity response, and time lag response. Additional pixel defects are identified during Express Calibration and Full Calibration Quality Limits • No 4 x 4 defect clusters. • Signal Uniformity = 2 % • Noise Uniformity = 40 % (lowest exposure), 31% (1/3 gain calibration exposure), 28 % (gain calibration exposure), 28 % (2 times gain calibration exposure) • Two Dark Noise = 9.2 ADC Wireless FAQs What impact will the system AP have on the Hospital/Clinic WLAN? The system AP will have the channel fixed and the transmit power reduced to the minimum level needed for reliable operation of the detector moving around the room in which the AP is installed. Because of the intermittent bursts of data lasting only a few seconds, and the low transmission power, the impact of the system WLAN on the Hospital mobile devices is minimized. 7–2 AC3451 | 2016-04-29 DRX Plus Statements Related to Systems Integration What is the range of the wireless communication? The wireless communication should have plenty of range for any single room installation. The connection range is typically more than 30 m, depending on the obstructions between the access point and the detector AC3451 | 2016-04-29 7–3 DRX Plus Statements Related to Systems Integration 7–4 AC3451 | 2016-04-29 Publication History Version Date A 2015-06-16 First release B 2016-02-10 Updated the specifications for MTF and DQE. C 2016-04-29 Added information for 4343 detectors. AC3451 | 2016-04-29 Changes I Carestream Health 150 Verona Street Rochester, NY 14608 USA © Carestream Health, Inc., 2016 Created in the United States CARESTREAM is a trademark of Carestream Health. Pub. No. AC3451 Rev. C