NOT FOR OPERATIONAL USE !!! Length to elevator: 73.86m to tail: 73.08m General Electric GE90-115B C L Jettison Nozzle VLV L1 2 ON ER L AIL TO PSA 4 C 6 7 ISOL ISOL APU BAT CHARG C1 STBY BUS CONVERTER 400 Hz ONLY 1 GEN BACKUP GEN 25kVA APU GEN EXT SEC GND SERVICE BUS AC Busses DC Busses Normal In-flight feed Alternate feeds Backup AC PWR Standby Battery only Standby with RAT S S R UTIL EXT PRI R GEN R R Backup IDG GEN AFT Outflow Valve Left HYD (Lemon) Center HYD (Cyan) Right HYD (oRange) Fuel Manifold APU Fuel Manifold Electrical Bleed Air Hot Air Conditioning Mechanical/other ACEs L2 (Color of HYD sys) PRSOV Pressure Regulating and Shut Off Valve Fan Air Precooler ENG Starter Valve C R 8 9 L2 R ENG Gearbox L2 10 11 ALTN PITCH TRIM Lever Actuator Control Electronics L1 Primary Flight Computers Power Supply Assembly L2 PFC-L L FCDC BUS PSA-L L DC BUS AP L2 R R STCM Stabilizer PFC SECONDARY MODE PFC APU Bleed VLV ACE AIR C 14 R RA ILER ON L1 ANALOG SIGNALS C AFDS-R AFDS-C AFDS-L R PFC-R C FCDC BUS PSA-C CAPT FLT INST BUS L ENG GEN PMG R ENG GEN PMG A/P ARINC F/CTL DATA BUS R FCDC BUS PSA-R R DC BUS R ENG GEN PMG 1 Min. BATTERY HOT BAT BUS 1 Min. BATTERY For colors see ELECTRICAL Legend - Bank protection 35° ->30° - Yaw Damper - Thrust Assymetry Comp. - Wheel to rudder x-tie - Gust suppression - Rudder trim - Rudder trim cancel switch - automatic speedbrakes - Spoilers 4,5,10,11 locked out - Proportional elevator command - Degraded yaw damping - Elevator feel with 2 feel forces - Both trim switch move directly the - Rudder trim - Rudder trim cancel switch stabilizer [ ] FLIGHT CONTROL MODE - no automatic speedbrakes DIRECT MODE - pitch control same R APU Starter VLV L1 13 - Stall protection - Overspeed protection - Elevator variable feel - Tailstrike protection - Trim reference speed with automatic pitch compensation for thrust, gear, flaps and speedbrakes changes, turbulences and turns to 30° bank ACE L1 C Non return Valve Pump Valve HYD motor Mechanical HYD Pump Electrical HYD Pump Pneumatical HYD Pump = Ventilation Fan Smoke Detector S Fire extinguisher bottle F ©PMG 4.2.2020, www.pmgasser.ch R 12 PFC-C L ENG GEN PMG M L STCM 150 100 [NM] 50 100 150 200 250 300 350 400 ALTERNATE - Electric, L and R AC BUS, direct [ ] FLAP/SLAT CONTROL 1 Min. BATTERY F M 200 [ ] FLAPS PRIMARY FAIL HOT BAT BUS APU Shut off VLV L2 250 - Flap load relief, Autoslat - Asymetry/uncommanded motion SECONDARY - Electric, L and R AC BUS via FSEU - Slat load relief >256kts - Asymetry/uncommanded motion S C R ATO LEV C R FLAP -ERON NORMAL MODE R PMG LE 7th, Anti Ice Valve R HYD S Bulk Cargo TO PSA L1 OTHER SYSTEMS ELECTRICAL LEGEND Rapid bottles F F AFT Cargo R XFR BUS ELECTRICAL LEGEND Cargo AC R MAIN BUS R BUS TIE F F F F DC APU BAT CHARG L BUS MAIN & APU TIE GEN 120kVA to CARGO FIREFWD Metered Bottles C2 R TRUs TRU TRU 120A - FWD and AFT outflow valves - CAC, Cabin Altitude Controller - 2 positive relief valves, opens at 9.1 psi - 4 negative relief valves - 1’ at CRZ FL Decompression - 1‘ des to FL 290 Profile - 4’ level at FL 290 FL - 1‘ des to FL 250 400 - 12’ level at FL 250 - 3‘ des FL 140, total 22’ 350 ~177NM no wind 300 9th, High Press Valve FLAPS & SLATS - Center Hydraulic PRIMARY FLAPS MOTORS CENTER HYD L MAIN AC BUS R MAIN AC BUS R MAIN DC BUS F/O FLT INST BUS TO PSA RAT GEN L UTIL = = C1 C2 C2 C HYD RAT MAIN BAT L MAIN BUS L ENG Gearbox R L FLAP -ERON TO PSA L XFR BUS L Backup L GEN IDG L2 5 R R ELEC DMD Right Fuel SYS same as Left without APU CTR L Override pump, valves R Wing Anti Ice Valve Jettison Pump and lines CTR L Jettison VLV Gear to gear Outer track 12.90m Nose wheel to main gear 31.22m 3 STBY INVERTER APU BAT BUS L GEN L1 RAT deploys if - both engines are failed and center system pressure is low, or - both AC transfer busses are unpowered, or - all three hydraulic system pressures are low APU BAT L PMG L2 APU Isol. VLV PRESSURIZATION 4th, Low Press Bleed X-feed VLVs BACKUP Power when : - only 1 main AC GEN available, or - one or both main AC busses is lost, or - APP mode is selected for autoland HOT BAT BUS L C1 TRU TRU Center Tank 82’900 Kg 1 L MAIN DC BUS CAPT FLT INST BUS TO PSA BAT BUS TO PSA M C L2 L HYD R ENG SOV - Loss of trim air, CACTCS will provide average temp ENG BLEED SYSTEM as secondary mode - only Rudder trim, no cancel switch RE LEV ATO R L2 ACE Height: 18.85m M ER R L Surge Tank Bleed system left wing identical Bleed Isol Valves to right L C R wing L ENG SOV DC APU PMP L FWD PMP L Main Tank 31’300 Kg Minimum width for 180° turn 56.50m SLATS MOTORS L ENG FUEL SPAR VLV L AFT PMP Width 64.80m L ELEC DMD L Jettison PMP Wing tip turn radius 48.80m R MAIN AC BUS L MAIN AC BUS CENTER HYD C RU DD Fuel nozzles manifolds 20 outer 10 inner , OFF in idle des L ENG FUEL VLV Fuel Metering Unit Fuel filter OIL / Fuel Heat exchanger 2nd stage ENG fuel pump 1st stage ENG fuel pump PFC Tanks - Main Tanks 31’300kg each - Center tank 82’900kg - Total 145’500kg usable Preflight: - Center Pumps ON if FUEL IN CENTER and more than 4800kg in center Inflight: - FUEL LOW CENTER -> switch OFF pumps - after 45min, scavenge of the 1200kg fuel remaining in center tank in around 90min with the main jettison pumps. Jettison: - rate 2500 kg/min with center tank - rate 1400kg/min without center tank - at least 3800kg remain in each main tank Bypass Valve Air Cycle Machine Heat Exchangers Flow Control & Shut OFF Valves ACM NORM BRK FLT CTL R REV 70 ACE 55’791kg 1360kg 50 60 40 Total main tank fuel [t] 30 Conditioned Air Manifold PSA 1300 Packs - CACTCS (Cabin Air Conditioning and Temperature Control System) - Each pack has fully redundant dual channel Upper Recirculation Fans - Flow Control & Shut Off Valves operate pneumatically, are Zone Trim Air Valves springloaded close without pressure. Without control from Trim Air Pressure & Shut Off Valves ASCPC, valve opens with pressure. Lower Recirculation Fans - Pack can operate in stanby cooling mode [] PACK MODE L,R AIR CONDITIONING Flight Cabin Zones Deck A B C D E F FLT CTLS 1500 S S S Cooling S RAT 1700 OVERRIDE mode [] EQUIP COOLING OVRD - Supply fans stop - Override valve close to supply and opens the skin exhaust - Vent fan stops - Cargo Heat Valve close, Vent Valve opens - Smoke is evacuated outboard per differential pressure FWD Cargo - 3 Starts in 60min for each starter, electrical and air driven - auto start if both AC XFR BUS lost - 200kg/h APU GEN on GND - 20kg/h per Pack on GND - 150kg/h at FL380 - APU BLEED available <22’000ft - 1 Fire Ext bottle for APU - on GND & ENG OFF => Auto Fire Ext 1900 40’823kg Override Valve Airplane Skin Supply Fans Air Filter Cabin Air R Pack Max. Imbalance, only for Normal OPS 2041kg Heating L Pack Imbalance [kg] 2100 APU Cargo Heat Valve FLAPS & GEAR FUEL Fuselage Width 6.2m R L ALTN BRK 239’950 kg 352’441 kg 351’535 kg 251’290 kg SS FWD Outflow Valve APU MZFW MTW MTOW MLW Vent Fan NG. STEER 375 million $ Equipment Cooling, normal mode - Supply fan runs, R primary, L backup - Override valve open to supply and close to the skin exhaust - Vent fan runs - Vent valve opens if TAT >12.8°C - Cargo valve opens if the Vent valve closes (mechanically linked) EQUIPMENT COOLING FWD Eqmt Center Main Eqmt Center Vent Valve FLT CTL L REV B777300ER Price Flight Deck - 27 million US$ - T/O Thrust max 115’540lbs / 513KN / ~110’000hp - MCT Thrust 110’000lbs - 1 FAN, 4 LP + 9 HP comp, 2 HP + 6 LP turbine - 22 carbon fiber fan blades - bypass ratio 9:1 - pressure ratio 42:1 - Thrust to weight ratio 6:1 - weight 8762kg - fan diameter 330 cm, engine length 728cm - N1 100% = 2355 RPM, limit 110.5% = 2602 RPM - N2 100% = 9332 RPM, limit 121% = 11292 RMP - EGT max 1090°C, 30 sec. 1095°C, MCT max 1050°C - Oil temperature, max 132°C, 15min 143°C - 2 Fire Ext bottles shared for both engines [ ] PRI FLIGHT COMPUTERS MECHANICAL BACKUP ALTN PITCH TRIM STABILIZER SPOILER 4 + 11 L1 R TAB ENGINES FLIGHT CONTROLS