500 Series 560 Surge Protective Device Submittal Specification General Specifications Maximum Continuous Operating Voltage Short Circuit Current Rating (SCCR) Operating Frequency Range EMI/RFI Noise Rejection Location Type Nominal Discharge Current (In) Standard Status Indication 120VAC 125%, all others 115% 200kAIC 47-63Hz 63dB Max Type 1 / Type 2 20kA LEDs, Relay Alarm Contacts, Built-in-Test ANSI/UL 1449 Third Edition UL 1283, cUL (Type 2 locations) NEMA 4 10 Years Parts, 5 Years Labor Certifications Standard Enclosure Warranty Life Cycle Surge Testing (10kA, 20kV, IEEE Cat. C3) Surge Rating 08-12 16-25 37 Per Mode 15,000 30,000 45,000 Per Phase 30,000 60,000 90,000 Model Number Configurator UL 1449 Third Edition, Type 1 VPRs Source Configuration YA YC DF _5 _6 _0 _ _ _ _ _A _ _ _G _1 _S SA Configuration & Voltage Single Split 120/240 VAC Phase, 3W+G 120/208 VAC YA YC Three Phase WYE, 4W+G Three Phase WYE, 4W+G DB DF Three Phase Delta, 3W+G Three Phase Delta, 3W+G Surge Rating 120/208 VAC 127/220VAC 277/480 VAC 254/440 VAC 240 VAC 480 VAC Connection Type N Available on 80kA-200kA (“08”-“20”) R Available on 80kA-375kA (“08”-“37”) 08 80kA Per Mode 160kA Per Phase 12 125kA Per Mode 250kA Per Phase 16 160kA Per Mode 320kA Per Phase 20 200kA Per Mode 400kA Per Phase 25 250kA Per Mode 500kA Per Phase 37 Wire Compression Lugs 375kA Per Mode 750kA Per Phase Rotary Disconnect Switch Wire Lug (N) 08-12 Disconnect (R) Wire Lug (N) 16-25 Disconnect (R) Wire Lug (N) 37 Disconnect (R) AxB D S Standard X Consult Factory for additional source configurations, Surge Ratings, Monitoring Options, Enclosure Ratings, Etc. Monitoring Option Available on 80kA-160kA (“08”-“16”) A Red & Green LED’s, Audible Alarm, Alarm Enable & Disable feature, 2 sets of Relay Alarm Contacts, Built-in-Test C Available on 80kA-160kA (“08”-“16”) D Available on 200kA-375kA (“20”-“37”) T C L-G L-L N-G 700 1200 1800 1000 1800 1800 700 1000 Remote Monitoring Panel Option constructed with the monitoring system on a remote panel - Perfect for custom installations. Additional Accessories “A” option plus Surge Counter “A” option plus Dual Surge Counter Harness Length Model Accessory 6 Feet “X27” 10 Feet “X57” 20 Feet “X59” Example Model #: 560YC20ARTG1X59 CUL Approvals For all applications requiring CUL approvals, change the SPD model number from a UL Type 1 (560xxxxxxxx1x) to a UL Type 2 (560xxxxxxxx2x) Available Option for ALL units Advanced Transient Detection System See publication SL-70109, TS-70109 0.44” 0.44” [11.1] Dimensional Information Surge Connection Rating Type L-N 700 1000 Advanced Transient Detection System A Web-Based Power Quality Monitor Integrated within a Surge Protection Device Wt Real-Time Measurements Event Logging with Time/Date Stamp Embedded Web Page Ethernet, MODBUS, RS-485 Communications SPD Health Status - % Protection remaining LCD Display 16” x 12” 17.25” 9.5” 35 lb. (406 x 305) (438) (241) (15.9 kg) 16” x 16” 17.25” 10” 45 lb. (406 x 406) (438) (254) (20.4 kg) AC C A 20” x 16” 21.25” 10” 55 lb. (508 x 406) (540) (254) (24.9 kg) 20” x 20” 21.25” 14” 85 lb. (508 x 508) (540) (356) (38.6 kg) 100 Emerson Parkway Binghamton, NY 13905 P (607) 721 8840 P (800) 288 6169 F (607) 722 8713 E contactsurge@emerson.com D D B B *9.0” 9.0” [229] (229) * Enclosure depth changes to 10.0” [254] when the “Advanced Transient Detection System” monitoring option is selected. SS-70101 Rev 2 1-15