AQ-F255 FEEDER PROTECTION NOW WITH LINE PROTECTION When we gave the most accurate protection relay in the world, line protection, we obviously couldn’t make just another line protection, we made the best one available on the market. The feeder protection AQ-F255 is now released with two new variants. The new functionality enables line protection in the well established product line for feeder protection. In addition to the full feeder protection functionality the B variant includes a fast and accurate line differential protection functionality. The C variant comes equipped with Distance protection including some revolutionary functionality, the protected line segment can now be divided int several segments depending on the type of line. The D variant will be equipped with both line differential and distance protection. DISTANCE PROTECTION LINE DIFFERENTIAL PROTECTION EXCLUSIVE FEATURES • with or without tele-protection communication • Line differential protection will utilize the 1ms simplified 16s/cycle FFT current calculation for fast response to master unit • Up to 5 different line segments in distance protection • up to 5 different line segments forward and reverse can be set • Setting of line parameters can be input by R/X values or Z/Ang values • IED calculates the electrical length of the line automatically when the parameters are set • Quadrilateral, MHO and offset MHO characteristics supported • Ultra fast communication between units on a dedicated process bus • Line differential protection distance between of the relays is defined by the connection media. With optic fiber up to 120km and with copper max 8–10km • Synchronizing of IED’s by prioritizing devices on process buss. • Compensation of transformers in line solutions • Fast process bus with prioritization of the devices UNIQUE FEATURE TO MAKE DISTANCE PROTECTION MORE ACCURATE THAN EVER BEFORE In the diagram there are 3 different line segments in in forward and reverse directions, addition to the 5 protection zones X Protected line forward Example of segments: Reverse Segment 2 Fwd Segment1: Zone5 non directional Seg men t3F wd Forward • Line length: 30km • Line R:0.26 W/km Zone1 Fwd Se gm en t1 Fw d • Line X:0.13 W/km Zone2 Fwd Segment2: Segment 2 Rev • Line length: 60km • Line R:0.54 W/km • Line X:0.4 W/km t1 en gm Se R v Re Zone3 Rev Segment3: Zone4 Rev Segm ent 3 Rev • Line length: 50km • Line R:0.85 W/km • Line X:0.38 W/km Forward Reverse Protected line reverse QUADRILATERAL CHARACTERISTICS Quadrilateral characteristics Forward and Reverse direction settings Restrain out of the characteristics Trip inside the characteristics Forward, reverse and non-directional settings Directional characteristics settings • Non directional resistive and reactive reach to forward and reverse direction can be set freely X reach setting 6 • Q2 resistive and Q4 reactive reach angle can be set freely 0…44 degrees • Q1 resistive reach can be reduced by maximum resistive reach setting Zone Reduction (not in MV) 8 4 2 Freely settable angle 90deg + setting. Max 44 degrees. 0 Maximum allowed R reach Set protected line R reach setting R reach angle follows the line setting -2 -2 0 2 4 6 8 Freely settable angle 90deg + setting. Max 44 degrees. Arcteq Relays Ltd Kvartsikatu 2 A 1 65300 Vaasa, Finland www.arcteq.fi sales@arcteq.fi Arcteq support line: +358 10 3221 388 EET 9:00 – 17.00