Maximo Data Integrity Revision 1; June 2020 Maximo Data Integrity Rev. 0 June 2020 DOCUMENT PROPERTIES Classification Procedure Criticality Critical Security Plains Internal Use Only OMS Sub-Element (if applicable) Choose an item. Control Type Controlled REGULATORY AND MANDATORY SOURCE DOCUMENTS Federal, State, and Local regulations. Federal, State, and Local regulatory required facility operating permits and/or conditions. RELATED DOCUMENTS Management of Change Abandonment and Other Pipeline and Tank Status Classifications Appendix A and B Examples of Replacement in King RIK and MOC: Technical (Equipment or Technology) MOC Maximo Document Disclaimer To ensure you are using the current and approved revision of this document, compare the revision number to the official document within the PlainsConnect eLibrary. All printed documents are considered uncontrolled. All exceptions, changes and/or revisions to content within this document will be approved by the Document Owner. Confidentiality All rights reserved. No part of this document may be produced or transmitted in any form or means without the written permission of Plains All American LP. Contact the Document Management Office, dmo@paalp.com for further information. All printed versions of PAA documentation are considered uncontrolled; to ensure current and approved revision of this document, users should compare the revision number and approval date to the official document within the PlainsConnect eLibrary. Page | ii Maximo Data Integrity Rev. 0 June 2020 Table of Contents 1 Introduction .............................................................................................................................. 1 1.1 2 New Records ........................................................................................................................... 2 2.1 Activating Functional Locations, Asset Records, and PM’s ............................................ 2 2.1.1 New Install ................................................................................................................. 2 2.1.2 Existing Equipment Not Previously in Maximo (Data Gathering) ............................ 2 2.2 Activating Facility Locations ............................................................................................. 2 2.2.1 New Facilities ............................................................................................................ 2 2.2.2 Existing Plains Facility Not Previously in Maximo (Data Gathering)........................ 2 2.3 3 Terms and Definitions ...................................................................................................... 1 Activating Pipeline Locations ........................................................................................... 2 2.3.1 Newly Constructed / Purchased Pipelines ............................................................... 2 2.3.2 Existing Plains Pipeline Not Previously in Maximo .................................................. 3 Changes to an Existing Asset, Location, Route or PM Record .............................................. 3 3.1 Regulated Locations & Assets ......................................................................................... 3 3.2 Non-Regulated Locations & Assets ................................................................................. 3 3.3 Erroneous Active Locations & Assets .............................................................................. 4 3.3.1 Devices Not Installed per the Original Construction MOC ....................................... 4 3.3.2 Devices Loaded from Legacy Databases ................................................................ 4 3.4 Erroneous Pending Locations & Assets .......................................................................... 4 3.5 Changing Status to Inactive on Regulated PM’s ............................................................. 4 3.6 Changing Status to Inactive on Non-Regulated / Reliability PM’s .................................. 5 3.7 Changing Status on Non-Regulated / Non-Reliability PM’s ............................................ 5 3.8 Changing the Master PM on an Active PM...................................................................... 5 3.8.1 Regulated Master PM to a Non-Regulated Master PM............................................ 5 3.8.2 Load Non-Regulated Master PM to a Regulated Master PM due to an Erroneous Data 5 3.8.3 Non-Regulated Master PM to a Regulated Master PM due to an Assets Regulatory Status Change ...................................................................................................... 6 3.8.4 3.9 4 Non-Regulated Master PM to Non-Regulated Master PM ....................................... 6 System Description Attributes .......................................................................................... 6 Changes to Existing Pipeline Segment & Facility Records .................................................... 6 All printed versions of PAA documentation are considered uncontrolled; to ensure current and approved revision of this document, users should compare the revision number and approval date to the official document within the PlainsConnect eLibrary. Page | iii Maximo Data Integrity Rev. 0 4.1 June 2020 Changing Status of Regulated Pipeline Segment ........................................................... 6 4.1.1 Pipeline Operational Change Occurred after September 1st, 2018 (Adoption of Plains MOC process)............................................................................................................... 6 4.1.2 Pipeline Operational Change Occurred Before September 1st, 2018 (Adoption of Plains MOC process)............................................................................................................... 7 4.2 Changing Status of Non-Regulated Pipeline Segment ................................................... 7 4.2.1 Pipeline Operational Change Occurred after September 1st, 2018 (Adoption of Plains MOC process)............................................................................................................... 7 4.2.2 Pipeline Operational Change Occurred Before September 1st, 2018 (Adoption of Plains MOC process)............................................................................................................... 7 4.3 Changing Status of a Regulated Facility ......................................................................... 7 4.3.1 Facility Operational Change Occurred after September 1st, 2018 (Adoption of Plains MOC Process) .............................................................................................................. 7 4.3.2 Facility Operational Change Occurred Before September 1st, 2018 (Adoption of Plains MOC Process) .............................................................................................................. 8 4.4 Changing Status of a Non-Regulated Facility ................................................................. 8 4.4.1 Facility Operational Change Occurred after September 1st, 2018 (Adoption of Plains MOC Process) .............................................................................................................. 8 4.4.2 Facility Operational Change Occurred Before September 1st, 2018 (Adoption of Plains MOC Process) .............................................................................................................. 8 5 6 Changing Due Dates on Scheduled Work Orders .................................................................. 8 5.1 SCHED Regulatory PM Work Order ................................................................................ 8 5.2 SCHED Regulated and Non-Regulated 5, 10, & 20 Year Tank Inspection Work Order 9 5.2.1 Due to Erroneous PM Next Due Date (Data Upload from Ops Info) ....................... 9 5.2.2 Due to Work Not Being Completed .......................................................................... 9 5.3 SCHED Non-Regulated / Reliability PM Work Orders .................................................... 9 5.4 SCHED Non-Regulated / Non-Reliability PM Work Orders ............................................ 9 Cancelling Scheduled Work Orders ...................................................................................... 10 6.1 SCHED Regulated PM Work Orders ............................................................................. 10 6.1.1 SCHED Non-Regulated PM Work Orders .............................................................. 10 6.1.2 MOC SCHED CM Work Orders for Devices Not Installed per the Original Construction 10 6.2 SCHED Non-Regulated / Reliability PM Work Orders .................................................. 10 6.3 SCHED Non-Regulated / Non-Reliability PM Work Orders .......................................... 11 All printed versions of PAA documentation are considered uncontrolled; to ensure current and approved revision of this document, users should compare the revision number and approval date to the official document within the PlainsConnect eLibrary. Page | iv Maximo Data Integrity Rev. 0 6.4 SCHED Regulated and Non-Regulated 5, 10, & 20 Year Tank Inspection Work Order 11 6.4.1 7 June 2020 Due to Erroneous PM Next Due Date .................................................................... 11 6.5 Due to Work Not Being Completed................................................................................ 11 6.6 SCHED CM Work Orders............................................................................................... 11 Changing Next Due Dates on an Active PM ......................................................................... 11 7.1 Active Regulated PM's ................................................................................................... 11 7.1.1 Pushing PM Date Later than the Current PM Next Due Date................................ 12 7.1.2 Pushing PM Date Earlier than the Current PM Next Due Date ............................. 12 7.2 Non-Regulated / Reliability PM's ................................................................................... 12 7.3 Non-Regulated / Non-Reliability PM's ........................................................................... 12 7.4 Regulated and Non-Regulated 5, 10, & 20 Year Tank Inspection PM’s ....................... 12 7.4.1 Due to Erroneous PM Next Due Date (Data Upload from Ops Info) ..................... 12 7.4.2 Pushing PM Date Earlier than the Current PM Next Due Date ............................. 13 7.4.3 Pushing PM Date Later than the Current PM Next Due Date................................ 13 Appendix A – Revision History Table ........................................................................................... 14 All printed versions of PAA documentation are considered uncontrolled; to ensure current and approved revision of this document, users should compare the revision number and approval date to the official document within the PlainsConnect eLibrary. Page | v Maximo Data Integrity Rev. 0 June 2020 1 Introduction The practices outlined in this procedure are intended to define requirements for making changes to Maximo Data, in order to ensure the integrity of the data is maintained in line with Plains All American’s (PAA) policies and procedures. 1.1 Terms and Definitions Term definitions associated with this document are defined below. Term/Acronyms Definition Administrative Service Request A work request entered into Maximo that goes to the Houston Maximo Support team for review and completion. Asset A specific piece of equipment, such as a pump, valve, motor etc. Assets include components, (children), but do not include subcomponents, subassemblies, or parts, such as rotating elements, seals, gaskets, etc. Corrective Maintenance (CM) One time work orders are classified as CM work orders. Location An entity that houses one or more operating assets e.g., station, valve, site, rectifier site, pipeline segment, facility. Master PM The template used for a PM that designates regulation, lead time, job plan, work type details and frequency. MOC Management of Change PM (Preventative Maintenance) Provides the link between job plans and the assets or locations to which they apply. Routine work orders are automatically generated from here. Reliability PM’s Tank Mixer Maintenance, Pump Maintenance, and any other PM’s directed by the Technical Services Group. Table 1.1-1 Terms, Acronyms, and Definitions All printed versions of PAA documentation are considered uncontrolled; to ensure current and approved revision of this document, users should compare the revision number and approval date to the official document within the PlainsConnect eLibrary. Page | 1 Maximo Data Integrity Rev. 0 June 2020 2 New Records The following pertains to what documentation is required to activate Functional Locations, Asset Records, PM’s, Facility Locations and Pipeline Locations in Maximo. 2.1 Activating Functional Locations, Asset Records, and PM’s 2.1.1 New Install Activating equipment that is newly installed in the field and then subsequently built in Maximo, requires that the Management of Change (MOC) number associated with the install is referenced in the Administrative Service Request. The MOC should clearly identify the equipment to be activated in Maximo, which will be verified by the Maximo Operational Support Team prior to activating the Maximo record. 2.1.2 Existing Equipment Not Previously in Maximo (Data Gathering) Regulated valves, regulated overpressure safety devices, regulated pumps and all tanks identified in the field that were not previously in Maximo, need to be identified with an MOC, and that MOC number needs to be referenced in the Administrative Service Request. All nonregulated equipment identified in the field as a result of data gathering does not require an MOC to be activated in Maximo. 2.2 Activating Facility Locations 2.2.1 New Facilities To activate a newly constructed or purchased facility in Maximo, the associated MOC number must be referenced in the Administrative Service Request. Additionally, a completed Station Data Sheet must also be attached to the Administrative Service Request. 2.2.2 Existing Plains Facility Not Previously in Maximo (Data Gathering) To activate regulated facilities identified in the field that were not previously in Maximo, the associated MOC number must be referenced in the Administrative Service Request. Activation of all non-regulated facility locations identified in the field does not require an MOC; however, a completed Station Data Sheet must be attached to the Administrative Service Request. 2.3 Activating Pipeline Locations 2.3.1 Newly Constructed / Purchased Pipelines Activating a newly constructed / purchased pipeline location in Maximo, requires that the associated MOC number is referenced in the Administrative Service Request. If applicable, a Geographical Information System (GIS) Snapshot can also be attached to the Administrative All printed versions of PAA documentation are considered uncontrolled; to ensure current and approved revision of this document, users should compare the revision number and approval date to the official document within the PlainsConnect eLibrary. Page | 2 Maximo Data Integrity Rev. 0 June 2020 Service Request (sometimes it is necessary to activate the Pipeline in Maximo before GIS is updated to reflect the new Pipeline). 2.3.2 Existing Plains Pipeline Not Previously in Maximo When activating an existing Plains Pipeline location not previously in Maximo, an MOC is not required; however, a GIS Snapshot is required to be attached to the Administrative Service Request. If the Plains Pipeline is not in GIS, please contact the GIS department and follow their guidance to have the Plains pipeline add to the GIS system, to ensure the Pipeline location can be activated in Maximo. 3 Changes to an Existing Asset, Location, Route or PM Record The following pertains to what documentation is required to change the status of Locations, Assets, PM’s, Master PM’s, and O&M owned Attribute records in Maximo. 3.1 Regulated Locations & Assets When changing the status to Inactive, Sold, Idle, Abandoned, Retired or Removed, the following rules apply: If the change was made in the field after September 1, 2018 (adoption of Plains All American MOC Process), an MOC that includes approval of the changes by the Division HSE Manager is required. The MOC shall include a list of each location and/or asset being affected by the change and verbiage from the HSE Manager, stating that they approve the change in status to each location and/or asset listed on the MOC. Additionally, the HSE Manager shall state the new maintenance requirements after the status change. If the change was made in the field prior to September 1, 2018, then a written statement from the HSE Manager stating the status change needs to be attached to the Administrative Service Request. Additionally, the HSE Manager shall state the new maintenance requirements after the status change. For more information regarding Abandonment and Other Pipeline & Tank Status Classifications, please refer to Plains Policy P-195.402(c)(10). 3.2 Non-Regulated Locations & Assets When changing the status to Inactive, Sold, Idle, Abandoned, Retired or Removed, the following rules apply: If the change was made in the field after September 1, 2018 (adoption of PAA MOC Process), then an MOC that notes the specific location and/or asset being affected is required. The MOC shall also state the new maintenance requirements after status change. All printed versions of PAA documentation are considered uncontrolled; to ensure current and approved revision of this document, users should compare the revision number and approval date to the official document within the PlainsConnect eLibrary. Page | 3 Maximo Data Integrity Rev. 0 June 2020 If the change was made in the field prior to September 1, 2018, then a written statement from the Tech Manager, District Manager, or Division Director stating the status change needs to be attached to the Administrative Service Request. The Tech Manager, District Manager, or Division Director shall also state the new maintenance requirements after the status change. For more information regarding Abandonment and Other Pipeline and Tank Status Classifications, please refer to Plains Policy P-195.402(c)(10). 3.3 Erroneous Active Locations & Assets 3.3.1 Devices Not Installed per the Original Construction MOC When devices are not installed, per the original MOC for the construction of a new facility or pipeline, they are active in Maximo and the Location needs to be cancelled, the following rules apply; If the Location/Asset does not have any work order history, meaning work orders in a status of TECHCOMP, TECHRETURN, SUPRETRUN, SUPREVD, COMP, or CLOSED, Maximo Operations Support will cancel the active location. If the Location does have work order history, meaning work orders in a status of TECHCOMP, TECHRETURN, SUPRETURN, SUPREVD, COMP, or CLOSED, a MOC is required, or an updated equipment list needs to be attached to the original construction MOC to show that the specific device was not originally installed. 3.3.2 Devices Loaded from Legacy Databases To change the status of active devices loaded or entered into Maximo from a legacy database, that do not physically exist and have no demonstrated maintenance or inspection history in Maximo, a written statement from the District Manager validating the change needs to be attached to the Administrative Service Request. 3.4 Erroneous Pending Locations & Assets Devices in a pending status that do not physically exist and have no demonstrated maintenance or inspection history in Maximo, do not require an MOC to be referenced in the Administrative Service Request to be cancelled. 3.5 Changing Status to Inactive on Regulated PM’s When requesting that the status of a Regulated PM be changed to inactive, the following rules apply: If the change was made in the field after September 1, 2018 (adoption of PAA MOC Process), an MOC that includes approval of the changes by the Division HSE Manager All printed versions of PAA documentation are considered uncontrolled; to ensure current and approved revision of this document, users should compare the revision number and approval date to the official document within the PlainsConnect eLibrary. Page | 4 Maximo Data Integrity Rev. 0 June 2020 is required. The MOC shall include a list of each location, asset and/or PM being affected by the change and verbiage from the HSE Manager, stating that they approve the change in status to each Location/Asset/PM listed on the MOC. If the change was made in the field prior to September 1, 2018, then a written statement from the HSE Manager stating the status change needs to be attached to the Administrative Service Request (This includes removing a device from a route attached to a PM). 3.6 Changing Status to Inactive on Non-Regulated / Reliability PM’s When requesting that the status of a Non-Regulated / Reliability PM be changed to inactive, the following rules apply: If change was made in the field after September 1, 2018 (adoption of AA MOC Process), then an MOC that identifies the specific location and/or asset being affected, is required. If the change was made in the field prior to September 1, 2018, then a written statement from the Maintenance & Asset Management Manager stating they approve the status change needs to be attached to the Administrative Service Request. (This includes removing a device from a route attached to a reliability PM). Reliability PM’s are defined as: Tank Mixer Maintenance, Pump Maintenance, and any other PM’s directed by the Technical Services Group. 3.7 Changing Status on Non-Regulated / Non-Reliability PM’s To change the status of Non-Regulated / Non-Reliability PM’s to inactive, an MOC is not required in the Administrative Service Request. 3.8 Changing the Master PM on an Active PM 3.8.1 Regulated Master PM to a Non-Regulated Master PM To request that a PM’s Master PM Record is changed from a Regulated Master PM to a NonRegulated Master PM, an MOC that includes approval of the changes by the Division HSE Manager is required. The MOC shall include a list of each location, asset and/or PM being affected by the change and verbiage from the HSE Manager, stating the justification and approval of the change in regulatory status to each location, asset and/or PM listed on the MOC. 3.8.2 Non-Regulated Master PM to a Regulated Master PM due to an Erroneous Data Load To request that a PM’s Master PM Record is changed from a Non-Regulated Master PM to a Regulated Master PM, with no previous inspection history due to an erroneous data load, a All printed versions of PAA documentation are considered uncontrolled; to ensure current and approved revision of this document, users should compare the revision number and approval date to the official document within the PlainsConnect eLibrary. Page | 5 Maximo Data Integrity Rev. 0 June 2020 written statement from the HSE Manager validating the change request needs to be included with the Administrative Service Request. 3.8.3 Non-Regulated Master PM to a Regulated Master PM due to an Assets Regulatory Status Change To request that a PM’s Master PM Record is changed from a non-regulated Master PM to a regulated Master PM due to an assets regulatory status change, an MOC that includes approval of the changes by the Division HSE Manager is required. The MOC shall include a list of each location, asset and/or PM being affected by the change and verbiage from the HSE Manager, stating the justification and approval of the change in regulatory status to each location, asset and/or PM listed on the MOC. 3.8.4 Non-Regulated Master PM to Non-Regulated Master PM To request that a PM’s Master PM Record is changed from a non-regulated Master PM to a non-regulated Master PM, a written statement from appropriate individual validating the change must be included with the Administrative Service Request. 3.9 System Description Attributes To change the Set Point and Maximum Opertating Pressure (MOP) System Description owned attributes on active locations and/or assets, requires that the associated MOC number is referenced in the Administrative Service Request. The MOC shall list out each location and/or asset being affected by the change, and the new MOP and/or Set Point associated with each location and/or asset. 4 Changes to Existing Pipeline Segment & Facility Records The following pertains to documentation that is required to change the status of existing Pipeline Segments and Facility records. 4.1 Changing Status of Regulated Pipeline Segment 4.1.1 Pipeline Operational Change Occurred after September 1st, 2018 (Adoption of Plains MOC process) When changing the status to inactive, sold, idle, abandoned, retired, or removed, an MOC that includes approval of the changes by the Division HSE Manager is required. The MOC shall include a list of each location and/or asset being affected by the change and verbiage from the HSE Manager, stating that they approve the change in status to each location and/or asset listed on the MOC. Additionally, the HSE Manager shall state the new maintenance requirements after the status change. All printed versions of PAA documentation are considered uncontrolled; to ensure current and approved revision of this document, users should compare the revision number and approval date to the official document within the PlainsConnect eLibrary. Page | 6 Maximo Data Integrity Rev. 0 June 2020 4.1.2 Pipeline Operational Change Occurred Before September 1st, 2018 (Adoption of Plains MOC process) When changing the status to inactive, sold, idle, abandoned, retired, or removed, the Maximo status will be changed to align with the GIS pipeline status. If the GIS status is not aligned with the requested Maximo pipeline status, then the Maintenance Planner, or similar role, will need to work with GIS to make the necessary changes. For more information regarding Abandonment and Other Pipeline & Tank Status Classifications please refer to Plains Policy P-195.402(c)(10). 4.2 Changing Status of Non-Regulated Pipeline Segment 4.2.1 Pipeline Operational Change Occurred after September 1st, 2018 (Adoption of Plains MOC process) When changing the status to inactive, sold, idle, abandoned, retired, or removed, the MOC number associated with the change must be referenced in the Administrative Service Request. 4.2.2 Pipeline Operational Change Occurred Before September 1st, 2018 (Adoption of Plains MOC process) When changing the status to inactive, sold, idle, abandoned, retired, or removed, the Maximo status will be changed to align with the GIS pipeline status. If the GIS status is not aligned with the requested Maximo pipeline status, then the Maintenance Planner, or similar role, will need to work with GIS to make the necessary changes. For more information regarding Abandonment and Other Pipeline & Tank Status Classifications please refer to Plains Policy P-195.402(c)(10). 4.3 Changing Status of a Regulated Facility 4.3.1 Facility Operational Change Occurred after September 1st, 2018 (Adoption of Plains MOC Process) When changing the status to inactive, sold, idle, abandoned, retired, or removed, an MOC that includes approval of the changes by the Division HSE Manager is required. The MOC shall include a list of each location and/or asset being affected by the change and verbiage from the HSE Manager, stating that they approve the change in status to each location and/or asset listed on the MOC. Additionally, the HSE Manager shall state the new maintenance requirements after the status change. All printed versions of PAA documentation are considered uncontrolled; to ensure current and approved revision of this document, users should compare the revision number and approval date to the official document within the PlainsConnect eLibrary. Page | 7 Maximo Data Integrity Rev. 0 June 2020 4.3.2 Facility Operational Change Occurred Before September 1st, 2018 (Adoption of Plains MOC Process) If the change was made in the field prior to September 1, 2018, then a written statement from the HSE Manager stating the status change needs to be attached to the Administrative Service Request. Additionally, the HSE Manager shall state the new maintenance requirements after the status change. 4.4 Changing Status of a Non-Regulated Facility 4.4.1 Facility Operational Change Occurred after September 1st, 2018 (Adoption of Plains MOC Process) When changing the status to inactive, sold, idle, abandoned, retired, or removed, the MOC number associated with the change must be referenced in the Administrative Service Request. 4.4.2 Facility Operational Change Occurred Before September 1st, 2018 (Adoption of Plains MOC Process) When changing the status to inactive, sold, idle, abandoned, retired, or removed, a written statement from the Tech Manager, District Manager, or Division Director validating the change, needs to be included with the Administrative Service Request. 5 Changing Due Dates on Scheduled Work Orders The following pertains to the necessary documentation when a change is required to the due dates identified on scheduled work orders. 5.1 SCHED Regulatory PM Work Order Target Finish dates (due dates) will only be changed on Regulated scheduled work orders with an MOC that includes approval of the changes by the Division HSE Manager. The MOC shall include a list of each location, asset and/or work order being affected by the change and verbiage from the HSE Manager, stating the justification and approval of the change in regulatory due date to each location, asset and/or work order listed on the MOC. This also includes non-regulated work orders for: Non-DOT Valve Maintenance Semi Annual (Master PM 1113) Inspect & Calibrate Non-DOT Overpressure Safety Devices (Master PM 1162) Inspect & Calibrate Non-DOT Overpressure Safety Device Contractor Only (Master PM 1467) Inspection of Non-DOT Tanks Monthly (Master PM 1102) Internal Inspection of Non-DOT Tanks (Master PM 1384) Inspection of Non-DOT Tanks 10 Year (Master PM 1104) All printed versions of PAA documentation are considered uncontrolled; to ensure current and approved revision of this document, users should compare the revision number and approval date to the official document within the PlainsConnect eLibrary. Page | 8 Maximo Data Integrity Rev. 0 June 2020 Inspect Non-DOT Tank Overfill Protection Devices Monthly (Master PM 1115) Tank Inspection Monthly (Master PM 1172) 5.2 SCHED Regulated and Non-Regulated 5, 10, & 20 Year Tank Inspection Work Order 5.2.1 Due to Erroneous PM Next Due Date (Data Upload from Ops Info) To change due dates on scheduled regulated and non-regulated 5, 10, & 20 year operations tank inspections due to erroneous data upload from Ops Info, a written statement from the Director of Operations Tech Support that includes the justification of the change needs to be attached to the Administrative Service Request. No MOC is required for this change. To change due dates on scheduled regulated and non-regulated 5, 10, & 20 year trucking tank inspections due to erroneous data upload from Ops Info, a written statement from the Trucking Division Director that includes justification of the change needs to be attached to the Administrative Service Request. No MOC is required for this change. 5.2.2 Due to Work Not Being Completed To change due dates on scheduled regulated and non-regulated 5, 10, & 20 year operations tank inspections due to the work not being completed, an MOC that includes approval of the changes by the Division HSE Manager, and Director of Operations Tech Support is required. The MOC shall include a list each work order being affected by the change and verbiage from the HSE Manager and Director of Operations Tech Support, stating that they approve the change of the target finish date to the work orders listed on the MOC. To change due dates on scheduled regulated and non-regulated 5, 10, & 20 year trucking tank inspections due to the work not being completed, an MOC that includes approval of the changes by the Division HSE Manager, and the Trucking Division Director is required. The MOC shall include a list each work order being affected by the change and verbiage from the HSE Manager and Trucking Division Director, stating that they approve the change of the target finish date to the work orders listed on the MOC. 5.3 SCHED Non-Regulated / Reliability PM Work Orders To change due dates on scheduled non-regulated / reliability PM work orders, a written statement from the Maintenance & Asset Management Manager approving the change must be attached to the Administrative Service Request. Reliability PM’s are defined as: Tank Mixer Maintenance, Pump Maintenance, and any other PM’s directed by the Technical Services Group. 5.4 SCHED Non-Regulated / Non-Reliability PM Work Orders All printed versions of PAA documentation are considered uncontrolled; to ensure current and approved revision of this document, users should compare the revision number and approval date to the official document within the PlainsConnect eLibrary. Page | 9 Maximo Data Integrity Rev. 0 June 2020 To change due dates on scheduled non-regulated / non-reliability PM work orders, a written statement from the Operations Supervisor approving the change must be attached to Administrative Service Request. 6 Cancelling Scheduled Work Orders The following pertains to the required documentation to cancel scheduled work orders. 6.1 SCHED Regulated PM Work Orders To cancel a scheduled regulated PM work order, an MOC that includes approval of the changes by the Division HSE Manager is required. The MOC shall include a list of each work order requesting to be cancelled and verbiage from the HSE Manager, stating the justification and approval of the cancellation of the work order listed on the MOC. 6.1.1 SCHED Non-Regulated PM Work Orders To cancel a scheduled non-regulated PM work order an MOC is required. The MOC shall include a list of each work order requesting to be cancelled and verbiage from the Tech Manager, District Manager, or Division Director, stating the justification and approval of the cancellation of the work order listed on the MOC. This only includes work orders for the tasks listed below: Non-DOT Valve Maintenance Semi Annual (Master PM 1113) Inspect & Calibrate Non-DOT Overpressure Safety Devices (Master PM 1162) Inspect & Calibrate Non-DOT Overpressure Safety Device Contractor Only (Master PM 1467) Inspection of Non-DOT Tanks Monthly (Master PM 1102) Internal Inspection of Non-DOT Tanks (Master PM 1384) Inspection of Non-DOT Tanks 10 Year (Master PM 1104) Inspect Non-DOT Tank Overfill Protection Devices Monthly (Master PM 1115) Tank Inspection Monthly (Master PM 1172) 6.1.2 SCHED CM Work Orders for Devices Not Installed per the Original Construction MOC If the Location on the work order has no inspection history, the Maximo Operations Support Group will move the SCHED work order into WSCHED status for the Maintenance Planner, or similar role, to then cancel. No MOC is required. 6.2 SCHED Non-Regulated / Reliability PM Work Orders All printed versions of PAA documentation are considered uncontrolled; to ensure current and approved revision of this document, users should compare the revision number and approval date to the official document within the PlainsConnect eLibrary. Page | 10 Maximo Data Integrity Rev. 0 June 2020 To cancel scheduled non-regulated / reliability PM work orders, a written statement from the Maintenance & Asset Management Manager approving the cancellation of the work order must be attached to the Administrative Service Request. Reliability PM’s are defined as: Tank Mixer Maintenance, Pump Maintenance, and any other PM’s directed by the Technical Services Group. 6.3 SCHED Non-Regulated / Non-Reliability PM Work Orders To cancel scheduled non-regulated / non-reliability PM work orders, the Maximo Pipeline Operations Support team will move these work orders into WSCHED status, and the Maintenance Planner, or similar role, can cancel the work order or schedule it at a later date. 6.4 SCHED Regulated and Non-Regulated 5, 10, & 20 Year Tank Inspection Work Order 6.4.1 Due to Erroneous PM Next Due Date To cancel a scheduled regulated or non-regulated 5, 10, & 20 year tank Inspection work order due to an erroneous PM next due date, a written statement from the Director of Operations Tech Support stating the justification and approval of the cancellation of the work order needs to be attached to Administrative Service Request. No MOC is required. 6.5 Due to Work Not Being Completed To cancel a scheduled regulated or non-regulated 5, 10, & 20 year tank inspection work order due to the work not being completed, an MOC that includes approval of the changes by the Division HSE Manager, and Director of Operations Tech Support is required. The MOC shall include a list each work order being affected by the change and verbiage from the HSE Manager and Director of Operations Tech Support, stating that they approve the cancellation of the work order listed on the MOC. 6.6 SCHED CM Work Orders To cancel scheduled CM work orders, the Maximo Pipeline Operations Support team will move these work orders into WSCHED status so the Maintenance Planner, or similar role, can then cancel the work order or schedule it at a later date. 7 Changing Next Due Dates on an Active PM The following pertains to the required documentation to change the next due date field on active PM’s. 7.1 Active Regulated PM's All printed versions of PAA documentation are considered uncontrolled; to ensure current and approved revision of this document, users should compare the revision number and approval date to the official document within the PlainsConnect eLibrary. Page | 11 Maximo Data Integrity Rev. 0 June 2020 7.1.1 Pushing PM Date Later than the Current PM Next Due Date To change the Next Due Date on an active regulated PM later than the current PM next due date, an MOC that includes approval of the changes by the Division HSE Manager is required. The MOC shall include a list of each PM requesting to have the next due date changed and verbiage from the HSE Manager, stating the justification and approval of the change to the PM next due date. 7.1.2 Pushing PM Date Earlier than the Current PM Next Due Date To change the next due date on an active regulated PM earlier than the current PM next due date, an MOC is not required as long as compliance obligations are met. A written statement from the Operations Supervisor needs to be attached to Administrative Service Request. This also includes non-regulated work orders for: Non-DOT Valve Maintenance Semi Annual (Master PM 1113) Inspect & Calibrate Non-DOT Overpressure Safety Devices (Master PM 1162) Inspect & Calibrate Non-DOT Overpressure Safety Device Contractor Only (Master PM 1467) Inspection of Non-DOT Tanks Monthly (Master PM 1102) Internal Inspection of Non-DOT Tanks (Master PM 1384) Inspection of Non-DOT Tanks 10 Year (Master PM 1104) Inspect Non-DOT Tank Overfill Protection Devices Monthly (Master PM 1115) Tank Inspection Monthly (Master PM 1172) 7.2 Non-Regulated / Reliability PM's To change the next due date on an active non-regulated / reliability PM, a written statement from the Maintenance & Asset Management Manager must be attached to the Administrative Service Request. Reliability PM’s are defined as: Tank Mixer Maintenance, Pump Maintenance, and any other PM’s directed by the Technical Services Group. 7.3 Non-Regulated / Non-Reliability PM's To change the next due date on an active non-regulated / non-reliability PM, a written statement from the Operations Supervisor must be attached to the Administrative Service Request. 7.4 Regulated and Non-Regulated 5, 10, & 20 Year Tank Inspection PM’s 7.4.1 Due to Erroneous PM Next Due Date (Data Upload from Ops Info) All printed versions of PAA documentation are considered uncontrolled; to ensure current and approved revision of this document, users should compare the revision number and approval date to the official document within the PlainsConnect eLibrary. Page | 12 Maximo Data Integrity Rev. 0 June 2020 To change the next due date on an active regulated and non-regulated 5, 10, & 20 year operations tank inspection PM, written documentation from the HSE Manager and Director of Operations Tech Support stating the justification and approval must be attached to Administrative Service Request. To change the next due date on an active regulated and non-regulated 5, 10, & 20 year trucking tank inspection PM, written documentation from the HSE Manager and the Trucking Division Director stating the justification and approval must be attached to Administrative Service Request. 7.4.2 Pushing PM Date Earlier than the Current PM Next Due Date To change the next due date on an active regulated and non-regulated 5, 10, & 20 year operations tank inspection PM earlier than the current PM next due date, an MOC is not required. A written statement from the Tank Supervisor must be attached to the Administrative Service Request. To change the next due date on an active regulated and non-regulated 5, 10, & 20 year trucking tank inspection PM earlier than the current PM next due date, an MOC is not required. A written statement from the Trucking Division Director must be attached to the Administrative Service Request. 7.4.3 Pushing PM Date Later than the Current PM Next Due Date To change the next due date on an active regulated and non-regulated 5, 10, & 20 year operations tank inspection PM later than the current PM next due date, an MOC that includes approval of the changes by the Division HSE Manager and Director of Operations Tech Support is required. The MOC shall include a list of each PM requesting to have the PM next due date changed and verbiage from the HSE Manager and Director of Operations Tech Support, stating the justification and approval of the change to the PM next due date. To change the next due date on an active regulated and non-regulated 5, 10, & 20 year trucking tank inspection PM later than the current PM next due date, an MOC that includes approval of the changes by the Division HSE Manager and the Trucking Division Director is required. The MOC shall include a list of each PM requesting to have the PM next due date changed and verbiage from the HSE Manager and the Trucking Division Director, stating the justification and approval of the change to the PM next due date. All printed versions of PAA documentation are considered uncontrolled; to ensure current and approved revision of this document, users should compare the revision number and approval date to the official document within the PlainsConnect eLibrary. Page | 13 Maximo Data Integrity Rev. 0 June 2020 Appendix A – Revision History Table Rev Date 0 June 2020 1 October 2020 MoC # Reason for Issue Document Creation 15900 HSE Organizational Changes Summary of Changes Transferred to new template and merged all sections to one document. Replaced “E&RC Director” verbiage with “HSE Manager.” All printed versions of PAA documentation are considered uncontrolled; to ensure current and approved revision of this document, users should compare the revision number and approval date to the official document within the PlainsConnect eLibrary. Page | 14