Always Be With You TOMATOENC CO., LTD. Located in Busan, South Korea CONTACT to DONG-SUNG, PARK (T. +82-70-4334-5321, CP. +82-10-4345-8077) E-mail: dspark@tomatoenc.com, http://www.tomatoenc.com Copyright © TOMATOENC CO., LTD. All rights reserved. Always Be With You TOMATOENC :: To Meet TOMATOENC is To Be World Class :: □ Establishment ◌ May. 01. 2004: Established TOMATO ENGINEERING Co., Ltd. ◌ July. 07. 2017: Established TOMATOENC Co., Ltd. This company was born from a split-up between the ‘TOMATO Engineering’ and renamed itself as ‘TOMATOENC’ □ Location and Contact Point ◌ DaeGwang B/D, 4F and 5F, 108, Geojeong-ro, Saha-gu, Busan, Korea ◌ TEL: +82-70-4334-5321, CP: +82-10-4645-8077 ◌ E-mail: dspark@tomatoenc.com / tec_tank@tomatoenc.com ◌ Contact to Dong-Sung, Park (CEO/Ph.D.) ◌ Website: www.tomatoenc.com Always Be With You Organization Design Department FEA Department Director Do-Hoon, Kim (김도훈 이사) CEO / Ph.D. Dong-Sung, Park (박동성 대표) API TEAM (CRT, DRT, EFRT, DWST, Spherical) ANALYSIS TEAM (ANSYS, FLUENT and STAAD Pro.) ASME TEAM (Pressure Vessel, Heater, etc) CALCULATION TEAM (In-House Program) SS TEAM (2D, 3D Steel Structure, etc) ◌ DESIGN Department: Fabrication Drawing, CP & BOM ◌ FEA Department: Strength Calculation, FE Analysis, CFD Analysis, Always Be With You Major Business :: Strength Calculation, Fabrication Drawing, FE Analysis :: □ Engineering Service for ‘Gas & Oil’, ‘Petrochemical’ and ‘Power Plant’ ▫ Cone Roof Tank, Dome Roof Tank, Floating Roof Tank (single, double) ▫ Double Wall Tank (App. “Q” and App. “R”): LPG, Propane, Ethylene, Ammonia, Propylene ▫ Spherical Tank: ASME Sec. VIII, Div. 1 & 2 ▫ Pressure Vessel, Heat Exchanger, Tower, Reactor ▫ HRSG, HP & LP Heater, Condenser, Absorber, Silo, Hopper, Desulfurization Equipment □ Engineering Service for ‘Steel Structures’ ▫ Platform, Tower Stair, Steel Structure, etc. □ Engineering Service for ‘Vendor Print Review’ ▫ Storage Tanks, Spherical Tanks, Steel Structures □ Engineering Service for ‘Quotation’ ▫ Strength Calculation, BOG Calculation, Engineering Drawing, Bill of Materials(BOM) Always Be With You FEA Department :: Strength Calculation, FE Analysis, CFD Analysis :: □ Staff: 6 members ▫ PhD: 1 person, Master: 2 persons, Bachelor: 3 persons □ Applicable Codes and Standards ▫ ASME SEC. VIII & SEC.III, ▫ API 650 & 625 & 620, API 579-1/ASME FFS-1 ▫ BS EN 14015, BS EN 14620, BS 7777-1 ▫ AISC-360(LRFD, ASD), EEMUA, ISO, IGF, India Code, Vietnam Code, etc. □ FE Analysis ▫ Thermal, Elastic, Elastic-Plastic, Buckling, Dynamic, Fatigue, Creep-Fatigue Analysis □ CFD Analysis : Steady-state, Transient, Sloshing, etc. □ Steel Structure Analysis □ Strength Calculation ▫ API 650 & 625 & 620, BS EN 14015, BS EN 14620, BS 7777-1, ASME Sec. VIII, EEMUA, etc. □ BOG Calculation: Double Wall Tank, Spherical Tank Always Be With You Design Department :: Engineering Drawing, Fabrication Drawing, CP & BOM :: □ Staff: 8 members ▫ Over 25 years: 2 persons, Over 17 years: 1 person, ▫ Over 10 years: 1 persons, Over 7 year: 2 persons, Over 1 year: 1 person □ Applicable Codes and Standards ▫ ASME Sec. III & Sec. VIII ▫ API 650 & 625 & 620, ▫ BS EN 14015, BS EN 14620, BS 7777-1 ▫ AISC-360(LRFD, ASD), India Code, Vietnam Code, etc. □ Engineering Drawing , Fabrication Drawing, CP & BOM ▫ Cone Roof Tank, Dome Roof Tank, Floating Roof Tank (single, double) ▫ Double Wall Tank (App. “Q” and App. “R”): LPG, Propane, Ethylene, Ammonia…. ▫ Spherical Tank: ASME Sec. VIII, Div. 1 & 2 ▫ Pressure Vessel, Heat Exchanger, HP&LP Heater, etc. ▫ Absorber, Silo, Hopper ▫ Steel Structures Always Be With You Software :: Drawing, Strength Calculation, FE Analysis, CFD Analysis :: □ FE Analysis ▫ ANSYS Mechanical 1 copy, ANSYS Professional 2 copies □ CFD Analysis ▫ ANSYS Fluent 1 copy, Design Modeler 1 copy □ Steel Structure Analysis ▫ STAAD. PRO 1 copy □ Drawing ▫ AutoCAD 11 copies, Tekla Structures □ Strength Calculation ▫ PV-Elite & Compress(outsourcing) - Pressure Vessel, Heat Exchanger, etc. ▫ In-House Program - API 650 Tank: CRT, DRT, Floating Tank (single, double) - API 620 Tank: DRT, Double Wall Tank (App. “Q” and App. “R”) - Spherical Tank (ASME Sec. VIII, Div. 1 & 2), AISC, EEMUA, etc. - BOG Calculation Always Be With You Formal Contract Kick-off Meeting Design Process Analysis of the User’s Design Specification Job Sharing (Calculation, Drawing, FE Analysis) Repetition Drawing(Design Dept.) Final Drawing (Design Dept.) Calculation FE Analysis(FEA Dept.) Initial Results Inform to Owner Final Results Inform to Owner Final Calculation Final FE Analysis Report Report (FEA Dept.) Always Be With You Calculation Service □ PV-Elite & Compress (outsourcing) ▫ Pressure Vessel, Heat Exchanger, Condenser, HP/LP Heater, Tower, Etc. □ In-House Program ▫ CRT, DRT, External Floating Tank, Double Wall Storage Tank, Spherical Tank ▫ BOG Calculation for Double Wall Storage Tank ▫ Mounded Storage Vessel 3. DEMENSION OF GEOMETRIC MODEL 3.1 DEMENSION OF GEOMETRIC MODEL ( TYPE-1 12. CALCULATION OF COLUMN SUPPORT BASED ON AISC 360 12.1 DEFINE GEOMETRIC PROPERTIES ) Round HSS [ Geometric Properties of Hollow Circle (Annulus) ] CA = 0.0 mm : Corrosion Allowance D = 200.0 mm : Diameter of Column t = 5.0 mm Fy = 262.0 MPa : Yield strength at design temperature 483.0 MPa : Tensile strength at design temperature 202350.0 MPa : Elastic modulus at design temperatrue Fu E = = : Uncorroded thickness of Column Section type of column Calculated Geometric Properties of Hollow Circle Ri = Ro Ag Ae 97.5mm : Inside radius of Column = 100mm : Outer side radius of Column = 1551.2 mm² : Geometric Area 1085.8 mm² : Geometric Effective Area, Assume that 0.7Ag = Iy = 7.56E+06 mm⁴ : Second Moment of Area about Y-axis Iz = 7.56E+06 mm⁴ : Second Moment of Area about Z-axis Ip = 1.51E+07 mm⁴ : Polar Moment of Inertia Sy = 7.56E+04 mm³ : Elastic section modulus Sz = 7.56E+04 mm³ : Elastic section modulus Zpy = 9.75E+04 mm³ : Plastic section modulus Inner Radius of tank ( Ri ) = 26700.0 mm = 13350.0 mm Zpz = 9.75E+04 mm³ : Plastic section modulus Maximum liquid leve ( H.L.L ) = 20000.0 mm ry = 69.83 mm rz = 69.83 mm Inner Diameter of tank ( D i ) Notation [i] Angle, Φi [ deg˚ ] Height, Hi [ mm ] Min_thk, tmin [ mm ] 1 5.625 26700.0 63.0 Corr.thk, t* [ mm ] 60.0 2 11.25 26635.7 63.0 60.0 3 11.25 26125.2 63.0 60.0 4 37.5 25123.6 63.0 60.0 5 24.375 18859.6 63.0 60.0 6 24.375 13350.0 63.0 60.0 7 37.5 7840.4 63.0 60.0 8 11.25 1576.4 63.0 60.0 9 11.25 574.8 63.0 60.0 10 5.625 64.3 63.0 60.0 : Radius of Gyration about Z-axis Formula of Geometric Properties of Hollow Circle = = = = = = = = = = ::BOG:: : Radius of Gyration about Y-axis = ::Spherical Tank:: = Always Be With You Drawing Service :: Refrigerated Liquefied Gas Storage (Double Wall Storage Tank) :: LPG Storage Tank Ammonia Storage Tank Propane Storage Tank Propane Storage Tank Ethylene Storage Tank Always Be With You Drawing Service :: Cone, Dome and Floating Roof Tank :: Cone Roof Dome Roof Floating Roof 1:12 Truss Sulfur Tank 1:12 Truss Always Be With You Drawing Service :: Spherical Tank :: Always Be With You Drawing Service :: Absorber, Silo, Pressure Vessel, HP Heater :: Absorber Vessel (IGCC) Silo HP Heater Always Be With You Drawing Service :: Steel Structures :: Stair Tower Roof Platform Roof Platform Roof Platform Roof Platform Always Be With You 3D Modeling Service :: Propane Storage Tank using Tekla Structures :: Always Be With You Analysis Service :: Refrigerated Liquefied Gas Storage (Double Wall Storage Tank) :: Thermal Buckling Dynamic Modal Anchor strap ,Nozzle, Internal; Pipe and Support Roof Platform Always Be With You Analysis Service :: Cone Roof Tank :: Elastic Analysis Elastic-Plastic Analysis Always Be With You Analysis Service :: Spherical Tank, Pressure Vessel, HP heater, Heat Exchanger :: Always Be With You Analysis Service :: CFD Analysis for MSR, Duct and LPG Tank :: Always Be With You Analysis Service :: Structural Analysis for Stair Tower :: Using ANSYS Using STAAD PRO Always Be With You Analysis Service :: ANSYS and STAAD PRO Combination :: ANSYS STAAD PRO Always Be With You Troubleshooting Shell Deformation during Fabrication Thin Wall Collapse Cause by Wind Load (no stiffener) Roof Collapse Cause by Vacuum Pressure