Tabulation of Design Standards: P.D 1096: Building Code, P.D. 1185: Fire Code, P.D. 957: Subdivision & Condominium Law, B.P. 220: Economic & Socialized Housing & B.P. 344: Accessibility Law P.D 1096 Building Code P.D 1185 Fire Code P.D 957 Subdivision & Condominium Law B.P 220 Economic Housing B.P 220 Socialized Housing B.P 344 Accessibility Law N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A Occupant Load Maximum of 90% of the lot Maximum of 80% of the lot At least 250 mm thick, 600 mm below ground surface 18.6 sq. m/ person N/A 18.6 sq. m/ person At least 200 kg. / sq. .m At least 150 kg. / sq. m At least 750 mm Max. of 200 mm At least 200 mm N/A N/A No. of units Multiplied by 6 N/A N/A Live Load @ 1st floor Live Load @ 2nd floor Stair Width Stair Riser Stair Tread No. of units Multiplied by 6 N/A N/A N/A N/A N/A N/A 1.10 m 200 mm 250 mm 600 mm 200 mm 250 mm 600 mm 200 mm 250 mm Entrance & Exit At least 1 entrance & 1 exit N/A N/A N/A Refer to Fire Code Specifications (Too many to tabulate) At least 1 entrance & 1 exit At least 1 entrance & 1 exit At least 1 entrance & 1 exit Subject Residential Requirements Corner Lot Inside Lot Foundation Light & Ventilation Min. dimension of court Passageway from Inner Court N/A N/A 2.00 m N/A 1.50 m 2.00 m 2.00 m N/A At least 1.20 m N/A At least 1.20 m At least 1.20 m At least 1.20 m N/A 1 Min. Ht. Clearance from Firewall Headroom Clearance Min. Ceiling Ht. for Habitable Rooms Min. Ceiling Ht. for Buildings 1.00 m above the roof 2.00 m 2.40 m – Artificial Ventilation 2.70 m – Natural Ventilation 2.70 m – 1st Storey 2.40 m – 2nd Storey 2.10 m – Succeeding Storeys 1.80 m – Mezzanine N/A 1.00 m above the roof 2.00 m 1.00 m above the roof 2.00 m N/A 2.40 m 2.40 m N/A 2.00 m 1.80 m - Mezzanine 2.00 m 1.80 m - Mezzanine 2.00 m 1.80 m - Mezzanine Less than 50% of total area of the wall on that storey Less than 25% of total area of the wall on that storey Less than 25% of total area of the wall on that storey At least 10% of the floor area N/A At least 10% of the floor area N/A At least 10% of the floor area N/A N/A P.D 957 Subdivision & Condominium Law B.P 220 Economic Housing B.P 220 Socialized Housing B.P 344 Accessibility Law N/A N/A N/A N/A 18 sq. m for studio unit N/A N/A N/A N/A N/A N/A N/A N/A 2.25 sq. m At least 1 exit At least 1 exit N/A 2.00 m 2.30 m Window Openings At least 10% of the floor area At least 750 mm N/A Size/ Dimension of Rooms P.D 1096 Building Code P.D 1185 Fire Code Rooms for Human Habitation Kitchens 6.00 sq. m w/ min. dimension of 2.00 m 3.00 sq. m w/ min dimension of 1.50 m 1.20 sq. m w/ min. dimension of 0.90 m N/A Exits Occupant Load of less than 10 At least 1 exit N/A N/A 2.13 m Less than 50% of total area of the wall on that storey Toilet & Bath 2.40 m – Artificial Ventilation 2.70 m – Natural Ventilation 2.30 m Sum of Areas of Openings in any Storey Eaves over required windows 1.00 m above the roof 2.00 m N/A N/A At least 2 exits At least 1 exit N/A N/A 2 Occupant Load of 10-499 Occupant load of 500-999 Occupant Load of 1000-above Distance to exits without Sprinkle System Distance to exits with Sprinkle System Min. exit door width Min. exit door height Min. corridor width Max. slope of passageway Dead ends At least 2 exits N/A At least 2 exits N/A N/A N/A At least 3 exits N/A At least 3 exits N/A N/A N/A At least 4 exits N/A At least 4 exits N/A N/A N/A Max. of 45 m Max. of 46 m Max. of 45 m Max. of 45 m Max. of 45 m N/A Max. of 60 m Max. of 61 m Max. of 60 m Max. of 60 m Max. of 60 m N/A 700 mm 710 mm 700 mm 800 mm 800 mm N/A 2.00 m 2.00 m 2.00 m 2.00 m 2.00 m N/A 1.10 m 550 mm 1.10 m 1.20 m 1.20 m 1.20 m 1:8 N/A 1:8 1:8 1:8 Max. of 6.00 m Max. of 6.00 m Max. of 12.00 m Max. of 12.00 m Max. of 12.00 m N/A Stairways for Buildings P.D 1096 Building Code P.D 1185 Fire Code P.D 957 Subdivision & Condominium Law B.P 220 Economic Housing B.P 220 Socialized Housing B.P 344 Accessibility Law Min. stair width: Occupant load of 10-below Min. stair width: Occupant load of 10-50 Min. stair width: Occupant load of 50 - above Riser 750 mm N/A N/A N/A N/A N/A 900 mm N/A 900 mm 900 mm 900 mm N/A 1.10 m N/A 1.10 m 1.00 m 1.00 m N/A 200 mm 200 mm 200 mm N/A Tread 250 mm 250 mm 250 mm 250 mm N/A 200 mm 190 200 250 230 mm mm mm mm class class class class A B A B 3 Min. width Distance bet. Landings 1.10 m 3.60 m 1.12 m 2.75 m class A 3.70 m class B 1.10 m 3.60 m 600 mm 3.60 m 600 mm 3.60 m N/A N/A Dimension of Landings in the direction of travel Height of handrails Equal to the width of the stairway 1.12 m Equal to the width of the stairway Equal to the width of the stairway N/A 800-900 mm from the nosing 760-895 mm from the nosing Equal to the width of the stairway 800-900 mm from the nosing 800-1200 mm from the nosing 800-1200 mm from the nosing 700-800 mm from the floor P.D 1096 Building Code P.D 1185 Fire Code P.D 957 Subdivision & Condominium Law B.P 220 Economic Housing B.P 220 Socialized Housing B.P 344 Accessibility Law Min. of width of sidewalk 1/6 of R.O.W N/A 1.00 m for major road & minor roads 1.00 m for major road & 500 mm minor road 1.00 m for major road & 500 mm minor road N/A Plan Strip 800 mm for sidewalks exceeding 2.00 m in width N/A 1.00 m for major road & minor roads 1.00 m for major road & 500 mm minor road 1.00 m for major road & 500 mm minor road N/A 1:3 or 1:4 N/A 1:3 or 1:4 N/A N/A N/A 1:10 10% 1:10 15% 15% 1:12 but length shall not exceed 6.00 m w/o landing 50% Residential 25% others 20% Residential 15% others N/A 50% Residential 25% Others 20% Residential 15% Others 50% Residential 25% Others 20% Residential 15% Others 50% Residential 25% Others 20% Residential 15% Others N/A Sidewalks & Arcades Driveways, Entrance & Exits Slope of entryway Max. slope of ramps Open Space Requirements Interior Lots Inside Lots N/A N/A 4 Corner/Through Lot Lot bounded by streets on 3 sides 10% Residential 5% others 5% for all occupancies N/A Setbacks P.D 1096 Building Code Low Density Residential (R-1) 5.00 m Front 2.00 m Side 2.00 m Rear 3.00 m Front 2.00 m Side 2.00 m Rear 2.00 m Front 2.00 m Side 2.00 m Rear Medium Density Residential (R-2) High Density Residential (R-3) 10% Residential 5% Others 5% for all Occupancies 10% Residential 5% Others 5% for all Occupancies 10% Residential 5% Others 5% for all Occupancies N/A P.D 1185 Fire Code P.D 957 Subdivision & Condominium Law B.P 220 Economic Housing B.P 220 Socialized Housing B.P 344 Accessibility Law N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A 3.00 m Front 2.00 m Side 2.00 m Rear 1.5 m Front 2.00 m Side 2.00 m Rear 1.5 m Front 2.00 m Side 2.00 m Rear N/A N/A 2.40 x 5.00 m (perpendicular & diagonal) 2.00 x 6.00 m (parallel) 2.40 x 5.00 m (perpendicular & diagonal) 2.00 x 6.00 m (parallel) 2.40 x 5.00 m (perpendicular & diagonal) 2.00 x 6.00 m (parallel) 3.70 x 5.00 m Pooled Parking 1 slot/ 10 units Pooled Parking 1 slot/ 10 units Pooled Parking 1 slot/ 10 units N/A 1 slot /8 units 1 slot/ 4 units 1 slot/ 1 unit 1 slot / 20 units 1 slot / 20 units N/A N/A N/A Parking Size of Parking Slot Low-income single detached living units w/ individual lot size not more than 100 sq. m 50 sq. m below 50-100 sq. m 100 sq. m above 2.40 x 5.00 m (perpendicular & diagonal) 2.00 x 6.00 m (parallel) Pooled Parking 1 slot/ 10 units 1 slot /8 units 1 slot/ 4 units 1 slot/ 1 unit N/A N/A 5