8/30/2021 Commercial Wiring Ch. 11-15 Flashcards | Quizlet Commercial Wiring Ch. 11-15 Study Commercial Wiring Ch. 11-15 Get access to all your stats, your personal progress dashboard and smart study shortcuts with Quizlet Plus. Unlock Progress Terms in this set (65) The owner is responsible to provide power to these areas: (HIE) 1. Heat for the common areas of the building. 2. Illumination for public areas such as hallways, stairways, & public toilet rooms 3. Elevator The lighting circuits that are 1. Continuous operation considered to be the owner's 2. Automatic Control responsibility can be divided 3. Manual control into six groups according to 4. Photocell control the method used to control the 5. Exit signs in a portion of the building circuit. What are those groups? 6. Timed control (CAMPET) The lighting circuits that are control the circuit considered to be the owner's responsibility can be divided into six groups according to the method used to __________. https://quizlet.com/190390200/commercial-wiring-ch-11-15-flash-cards/ 1/12 8/30/2021 The luminaires installed the11-15 Commercial WiringforCh. Commercial Wiring Ch. 11-15 Flashcards | Quizlet continuous Study stairway to the second floor and hallways are in continuous/non-continuous operation when the building is occupied. Why are the luminaires that are Because those spaces have no windows installed for the stairway to the second floor and hallways in continuous use when the building is occupied? The sump pump is an example an automatic control system. of equipment that is operated by a _________ control system. The photocell control device light-sensitive cell; amplifier; relay consists of a ________ cell and an _____ that increases the signal until it is sufficient to operate a ______ that controls the light. What kind of feature is An astronomic feature extremely desirable in a lighting control? An astronomic feature sunset; sunrise provides _______ ON and ______ OFF that change automatically, day by day, as the _____ and _______ times change every day. https://quizlet.com/190390200/commercial-wiring-ch-11-15-flash-cards/ 2/12 8/30/2021 Commercial Wiring Ch. 11-15 Flashcards | Quizlet The pump motorWiring of a sump Commercial Ch. 11-15 manual motor starter; float switch Study pump is protected by a ___________ ________ ___________, and is controlled by a __________ __________. What kind of high-efficiency a "machine-room-less" elevator. elevator is indicated in the specifications? In a "machine-room-less" elevator shaft; elevator; wall elevator, all the elevator lifting mechanism is located in the ______________, and it is either on the _______ or on the ________. Upgrade to remove ads The building's occupants will Only $3.99/month heating thermostat each have a ________ located within their particular area. The circuit to the boiler's optional standby power panel; so that the water will circulating pump will be continue to circulate if the utility power fails. supplied from the _________ panel. Why is it supplied from this location? https://quizlet.com/190390200/commercial-wiring-ch-11-15-flash-cards/ 3/12 8/30/2021 _____________ are to Wiring be run from Commercial Ch. 11-15 Commercial Wiring Ch. 11-15 Flashcards | Quizlet Separate feeders Study the main service equipment to each of the areas of the Commercial building. In the Commercial Building, panelboard; the area to be served each feeder will terminate in a ___________, which generally will be installed in __________. In general, panelboards are main feed busbars; vertically constructed so the ______ _______ busbars run vertically/horizontally for nearly the height of the panelboard. When using a 3-phase supply, six; three phases the incremental number is ____. this allows for a pole for each of the _____ _______ on both sides of the panelboard. The feeder overcurrent ampacity; conductor protection is sized for the _________ of the feeder____________. The ________ gives the load/area directory; nonelectrical in a wording that would be clear for ________ people to decipher and identify the circuit number for luminaires, receptacles, appliances, or equipment. https://quizlet.com/190390200/commercial-wiring-ch-11-15-flash-cards/ 4/12 8/30/2021 Commercial Wiring Ch. 11-15 Flashcards | Quizlet The reason for identifying the 11-15 Commercial Wiring Ch. safety Study system voltages and phases is for _________. Most large commercial 480Y/277 volts & 208Y/120 volts buildings use two voltages: Upgrade to remove ads Conductors for 480Y/277-volt Only $3.99/month brown, orange, yellow; gray system are generally ____, _____, and _____ for the ungrounded conductors, and _____ for the grounded conductor. Do not confuse the term room working space with ____. For system voltages of 0 to 150 3 feet volts to ground, the minimum depth of working space is _____. All working spaces must allow 90 degree for the opening of equipment doors and hinged panels to at least a ______ position. https://quizlet.com/190390200/commercial-wiring-ch-11-15-flash-cards/ 5/12 8/30/2021 Commercial Wiring Ch. 11-15 Flashcards | Quizlet Working space height is Ch. 11-15 Commercial Wiring 6.5 feet Study required to not be less than _______. Access to and egress from room itself refer to the actual working space requirements about electrical equipment and not to _______. Dry-type transformers are lighter in weight widely used because they are ___________ than comparably rated liquid-filled transformers. The service point is defined in Art. 100 as the point of connection between the facilities and the serving utility and the premises wiring. *Look at the informational note, too. The service point can be described as the point of The informational note for the demarcation between where the serving utility ends service point definition in Art. and the premises wiring begins. The serving utility 100 states generally specifies the location of the service point based on their conditions of service. NEC 230.71 permits not more six than _____ disconnects to serve as the building service disconnecting means. Upgrade to remove ads https://quizlet.com/190390200/commercial-wiring-ch-11-15-flash-cards/ Only $3.99/month 6/12 8/30/2021 Commercial Wiring Ch. 11-15 Flashcards | Quizlet Commercial Wiring Ch. 11-15 A ground fault occurs Study ungrounded "hot"; grounded; grounded when__________ conductor comes into contact with a ________ surface or _____ equipment. The lower the impedance, the Higher ____ the current flow. NEC 250.64C states that spliced grounding electrode conductor generally are not permitted to be _______ GFCI protection can be circuit breakers; receptacles attained using GFCI ______ or GFCI _________. NEC 110.16 has a requirement qualified persons; serious hazard of arc flash events. for placing a notice on certain equipment to warn ______________ of ____________. What kind of lighting is used in high-efficiency energy-saving fluorescent lighting the Commercial building? and LED lighting; incandescent lamps Very few _____ are used. A lumen is the amount of light time; area; distance; candela received in a unit of _______ on a unit ________ at a unit ___________ from the point source of one _________. CRI stands for Color Rendering Index https://quizlet.com/190390200/commercial-wiring-ch-11-15-flash-cards/ 7/12 8/30/2021 Commercial Wiring Ch. 11-15 Flashcards | Quizlet Commercial Wiring Ch. 11-15 What is CRI? What is the light-producing The ability of the lamp to portray objects as Study normally as possible. a tungsten wire called the filament element in an incandescent lamp? Upgrade to remove ads Lamps are usually selected Only $3.99/month wattage according to their _____ rating. Describe what 65PAR38/FL 65-watt parabolic reflector flood, 38/8 inch means (4.75) diameter The inside of the glass tube of phosphor (a fluorescing material) a fluorescent lamp is coated with _________________. Inside the tube of a fluorescent evacuated; inert; mercury lamp, the air is _________ and an ________ gas plus a small quantity of ______ is released into the tube. The instant-start lamps require single-pin bases _____________. https://quizlet.com/190390200/commercial-wiring-ch-11-15-flash-cards/ 8/12 8/30/2021 Commercial Wiring Ch. 11-15 Flashcards | Quizlet The instant-startWiring lamps areCh. 11-15 Commercial slimline lamps Study generally called ____________. The ballast limits the current uncorrected; 40; 60; 5; unity; capacitor through the lamp by providing a coil with high reactance in series with the lamp. An inductive circuit of this type has an _______ power factor of ____% to ____%. However the power factor can be corrected to within ____% of ____ by the addition of a ________. What are LED's? What could LED lighting be Light Emitting Diodes solid-state lighting referred to as? Beginning in the _______ edition 2008; luminaire of the NEC, the term ________ is used exclusively rather than lighting fixture or some variation of that term. Upgrade to remove ads https://quizlet.com/190390200/commercial-wiring-ch-11-15-flash-cards/ Only $3.99/month 9/12 8/30/2021 Previous editionsWiring of the NEC Commercial Ch. 11-15 Commercial Wiring Ch. 11-15 Flashcards | Quizlet fixture Study used the term luminaire followed by the term _________ (lighting fixture) in parenthesis The installation of luminaires, 410 lighting outlets, and supports is covered in Article _____. Article 410 sets forth the basic rough-in requirements for the installation (of luminaires, lighting outlets, and supports,) commonly referred to as the ___________. According to NEC 410.36 B, the bolts, screws, rivets luminaires have to be securely fastened to the ceiling members using _____, _____, or _____. Type IC luminaires are thermal insulation permitted to be installed in direct contact with ________________. All recessed incandescent factory-installed thermal protection luminaires must be equipped with ____________. NEC 410.115 C. https://quizlet.com/190390200/commercial-wiring-ch-11-15-flash-cards/ 10/12 8/30/2021 NEC 410.115 C exceptions are : 11-15 Commercial Wiring Ch. Commercial Wiring Ch. 11-15 Flashcards | Quizlet concrete; temperatures; thermal Study All recessed incandescent luminaires must be equipped with factory-installed thermal protection. 1. The only exceptions to the rule in 410.115 C are: if the luminaire is identified for use and installed in ______________, 2. If the construction and design of the luminaires are designed such that ____________ would be no greater than if the luminaires had __________ protection. What two types of conductors THWN-2 and THHN have an insulation temperature rating of 90 degrees celsius and generally meet the temperature requirement for connecting luminaires? For fluorescent and HID volt-ampere; ballast luminaires, the _____________allowance is based on the rating of the ___________. NEC 410.16 addresses the clothes closets special requirements for installing in _. https://quizlet.com/190390200/commercial-wiring-ch-11-15-flash-cards/ 11/12 8/30/2021 Often a feeder serves twoCh. or 11-15 Commercial Wiring Commercial Wiring Ch. 11-15 Flashcards | Quizlet Study panelboards, junction box, wireway, panelboard more panelboards, in which case either a ______ or ____ is installed or the feeder connects to the first panelboard and then is extended to others. The reason that 210.5(C) system voltage(s); phases requires that _______ and ______ be identified, is safety. Access to and egress from working space refer to the __________ requirements about electrical equipment, not to the room itself. https://quizlet.com/190390200/commercial-wiring-ch-11-15-flash-cards/ 12/12