REFERENCE MATERIAL CERTIFICATE Certified Reference Material Product Name HJ 827-2017 Carbamate Pesticides Mixture 154 50 -1000 µg/mL in Methanol ISO 17034 This certificate is designed in accordance with ISO 17034 and ISO Guide 31. This certified reference material (CRM) was designed, produced and verified in accordance with ISO/IEC 17025, ISO 17034 and a registered quality management system ISO 9001. Product Code DRE-A50000154ME Lot Number 2-H413734ME CERTIFIED Format Multicomponent Solution Expiry Date 16 Jun 2024 Storage Temp ≤ -10 ºC Compound Name Concentration ( ug/mL) Expanded Uncertainty U (ug/mL ) CAS Lot Number Purity (%) Amount (mg) RT (min) 2,3,5-trimethacarb 196.6 10 2655-15-4 2763.3.3P 98.8 19.90 1.22 Methomyl-oxime 987.4 50 13749-94-5 4798.421.2P 98.64 100.10 3.97 Methomyl 200.8 11 16752-77-5 1852.421.2P 99.9 20.10 6.39 3-hydroxycarbofuran 199.7 10 16655-82-6 2235.3.10P 97.4 20.50 8.46 Metolcarb 99.5 5.5 1129-41-5 2125.3.2P 99.5 10.00 11.53 Isoprocarb 49.59 2.9 2631-40-5 2236.3.1P 98.2 5.05 12.87 Propoxur 198.8 10 114-26-1 2042.421.1.4P 99.9 19.90 14.23 Fenobucarb 100.4 5.5 3766-81-2 2238.3.2P 99.4 10.10 14.50 Bendiocarb 199 10 22781-23-3 1909.421.1.1P 99 20.10 15.43 Promecarb 102 5.6 2631-37-0 1851.421.1.1P 99 10.30 15.80 Carbofuran 50.16 2.8 1563-66-2 1806.421.1P 99.53 5.04 16.69 Pirimicarb 50.31 2.8 23103-98-2 1636.421.1P 99 5.08 18.24 Carbaryl 199 11 63-25-2 1653.421.1P 99.5 20.00 19.09 Methiocarb 50.35 2.9 2032-65-7 1617.286.1P 95 5.30 19.57 The producer certifies that this reference material meets the specification stated in this certificate until the expiry date, provided it is stored unopened at the recommended temperature herein. Product warranties for this reference material are set out in the terms and conditions of purchase. Version 2 CERTIFIED BY CERTIFIED ON HuiChen Stavros, Ph.D. 18 Jun 2020 RM Release Page 1 of 2 REFERENCE MATERIAL CERTIFICATE Instrument LC/HRMS - Positive Mode CHRO MATO GRAM Column/Flow Vanquish C18+ 100mm x 2.1mm ID 1.5um Particle / 0.2 mL/min Intended Use This CRM is intended for use in a laboratory as a calibration and quality control standard or in method development for analytical techniques. Safety Proper precautions should be observed while handling. See Safety Data Sheet. Uncertainty The certified value(s) and uncertainty(ies) are determined in accordance with ISO 17034 with an 95% confidence level (k=2). Uncertainty is based on the Total Combined Uncertainty, including uncertainties of preparation, purity of neat materials, homogeneity, long-term stability testing, and transportation stability. LGC Group 7290-B Investment Drive North Charleston, SC 29418 United States T | +1 843 763 4884 F | +1 866 509 5146 E | dr.ehrenstorfer@lgcgroup.com Version 2 Method Details Mobile Phase A: Water w/0.1% Formic Acid Mobile Phase B: Acetonitrile w/ 0.1% Formic Acid Time 0.0 1.0 22 22.25 28.5 %A 95 95 5 5 95 Method of Preparation The certified value is based on gravimetric and volumetric preparation of this CRM. This CRM has been confirmed by the appropriate analytical techniques. Batch Information Solvent: Methanol w/ 0.1% Formic Acid, Lot no. 197713, 100 mL %B 5 5 95 95 5 Traceability The balances used for gravimetric measurements are calibrated with weights traceable to the national standards (NIST). The calibration of the balances is verified daily internally and annually by an external accredited calibration service. Only Class A glassware is used for volumetric measurements. Homogeneity Random replicate samples of the final packaged CRM have been analysed to prove homogeneity consistent with ISO 17034. Storage The CRM should be stored in the original sealed bottle at the indicated temperature. The producer of this reference material is registered to ISO 9001:2015 under 56 100 19560019 by TUV USA and accredited to ISO 17025:2017 and ISO 17034:2016 by A2LA with the accreditation numbers 3031.01 and 3031.02. ISO 17034 Instructions for Use The CRM should be used shortly after opening to avoid concentration changes due to evaporation. It is recommended to use 1 µL as the minimum sample size. If storage after opening is necessary, it should be transferred to an amber vial with minimum head space and a Teflon lined silicon septum. If handled as recommended, use period after opening is a maximum of 305 days for an estimated 5% drift in concentration as a result of analyte and/or solvent transpiration. Visit the support section of our website lgcstandards.com for a series of Dr. Ehrenstorfer Tech Tip videos and frequently asked questions. ISO 17034 Accredited Reference Material Producer Cert. No. 3031.02 Page 2 of 2