Safety Precautions 96M12530 General Precautions Dedicated Safety Relay for the GL-R GL-T11R Instruction Manual DANGER Introduction This instruction manual describes handling, operation, and precautionary information for the GL-T11R Safety Relay dedicated for use with the GL-R Series Safety Light Curtain. Read this instruction manual thoroughly along with the GL-R instruction manual and user manual before operating the GL-T11R in order to ensure the optimum performance and functionality of the GL-R and GL-T11R. Keep this manual readily available for reference. Ensure that the end user of this product receives this manual. This manual is the original instruction manual. The GL-T11R can also be used with GL-S Series Safety Light Curtains, but in this situation there are limitations on the functions that can be used. Carefully read both the GL-S instruction manual and this instruction manual to ensure that you fully understand the function limitations before using this product. Hereinafter, both the GL-R Series and GL-S Series of safety light curtains are referred to as GL. Precaution on Use Safety Headings ■ This instruction manual uses the following symbols that alert you to important safety information. Strict adherence to the instructions next to these heading is required at all times. DANGER NOTICE Point Reference • You must verify that the GL-T11R is operating correctly in terms of functionality and performance before starting the machine. • KEYENCE does not guarantee the functions and performance of the GL-T11R if it is used in a manner that differs from the GL-T11R specifications described in this instruction manual or if the GL-T11R is modified by the customer. • When using the GL-T11R to protect machine operators against a hazard or hazardous zone or using the GL-T11R as a safety component for any purpose, always follow the applicable requirements of the laws, rules, regulations and standards in the country or region where the GL-T11R is used. For such regulations, you should make direct contact with the regulatory agency responsible for occupational safety and health in your country or region. • Depending on the type of machine on which the GL-T11R is to be installed, there may be special safety regulations related to the use, installation, maintenance, and operation of the safety component, and such safety regulations must be fulfilled. The responsible personnel must install the GL-T11R in strict compliance with such safety regulations. • The responsible personnel must do the training to the assigned personnel for the correct use, installation, maintenance, and operation of the GL-T11R. "Machine operators" refers to personnel who have received appropriate training from the responsible personnel and are qualified to operate the machine correctly. • Machine operators must have specialized training for the GL-T11R, and they must understand and fulfill the safety regulations in the country or region in which they are using the GL-T11R. • When the GL-T11R fails to operate, machine operators must immediately stop the use of the machine and the GL-T11R and report this fact to the responsible personnel. • The GL-T11R is designed with the assumption that it would be correctly installed and operated in accordance with the installation and operation procedures described in this instruction manual. You must perform an appropriate installation of the GL-T11R after conducting a sufficient risk assessment for the target machine. • When disposing of the GL-T11R, make sure to follow requirements, rules, codes, regulations and laws regarding industrial wastes in countries or regions where the GL-T11R is used. • The GL-T11R should be processed as an industrial waste product when being disposed. It indicates a hazardous situation which, if not avoided, will result in death or serious injury. Operators DANGER It indicates a situation which, if not avoided, could result in product damage as well as property damage. It indicates additional information on proper operation. ■ Installation environment It indicates tips for better understanding or useful information. Indicates reference pages in this or another manual. DANGER 1 • In order to operate the GL-T11R correctly, the responsible personnel and machine operators must follow all procedures described in this instruction manual. • No person other than the responsible personnel and machine operators should be allowed to install or test the GL-T11R. • When performing electrical wiring, always fulfill the electrical standards and regulations for the country or region in which the GL-T11R is used. • The GL-T11R is not designed to be explosion-proof. Never use it in the presence of flammable or explosive gases or elements. • When using the GL-T11R in the presence of substances, such as heavy smoke, particulate matter, or corrosive chemical agents, confirm that such substances do not induce deterioration in product quality. • Be sure to confirm absolutely that there is nobody in the hazardous zone, before the interlock is released (i.e. the machine system restarts) by the interlock reset mechanism. Failure to follow this warning may result in significant harm to the machine operators, including serious injury or death. • Interlock reset mechanisms (such as switches) must be installed so that the whole hazardous zone can be checked by the responsible personnel. Interlock reset mechanisms should not be accessible from within the hazardous zone. • Use the GL-T11R within an enclosure of IP54 or higher. • Ensure there is space around the unit for ventilation. • Do not install the GL-T11R in the locations listed below: • Locations with high humidity and a risk of condensation • Locations where water will splash onto the GL-T11R • Locations where there are corrosive gases • Locations where any flammable gases or explosive gases exist • Locations where the GL-T11R may be directly subjected to vibration or impact • Locations where strong electromagnetic noise may affect the GL-T11R GL-T11R-IM-E ■ Target machine DANGER ■ Testing and Maintenance • The machine on which the GL-T11R is to be installed must be susceptible to an emergency stop at all operating points during its operation cycle. Do not use the GL-T11R for machines with irregular stop times. • Do not use the GL-T11R for power presses equipped with fullrevolution clutches. • The GL-T11R cannot be used as a PSDI because it does not fulfill the requirements of OSHA 1910.217(h). Refer to OSHA 1910.217 for the PSDI mode. • Do not use the GL-T11R to control (stop forward motion, etc.) trains, cars and other transportation vehicles, aircraft, equipment for use in space, medical devices, or nuclear power generation systems. DANGER Circuit design and wiring DANGER • Always turn off the power to the GL-T11R when performing electrical wiring. • You must fulfill the electrical standards and regulations in the country or region in which the GL-T11R is being used when you perform the electrical wiring. • Wiring shall be in accordance with IEC60204-1/EN60204-1 so that short-circuit between adjacent terminals is to be prevented. • To avoid the risk of electric shock, do not connect any of the GL-T11R inputs/outputs, except for the FSD, to DC power sources outside of the range of 24 V DC + 10% or to any AC power source. • To avoid the risk of electric shock, be sure that the hazardous voltage is isolated from all wiring of the GL-T11R with reinforced insulation or double insulation, except for the FSD. • In order to fulfill the requirements in IEC61496-1, UL61496-1, EN61496-1, UL508 and CAN/CSA-C22.2 No. 14, the power supply for the GL-T11R must fulfill the conditions listed below. (a)The rated output voltage of 24 V DC (SELV, Overvoltage Category ) within ± 10% (b)Double insulation or reinforced insulation between the primary and secondary circuits. (c)Output holding time of 20 ms or more. (d)A power supply must fulfill the requirements of the electrical safety and electromagnetic compatibility (EMC) regulations or standards in all countries and/or regions where the GL-T11R is used. (e)A secondary circuit of power supply (output) must fulfill the requirements for Class 2 Circuits or Limited Voltage/Current Circuits specified in UL508 and CAN/CSA-C22.2 No. 14 if the GL-T11R is used in the United States or Canada. • Do not install the electric wiring of the GL-T11R together with or in parallel with high-voltage electrical or power lines. • Both of the two FSDs provided on the GL-T11R must be used to establish a safety related machine control system. Establishing a safety related machine control system with just one of the FSDs cannot stop the machine in the event of an FSD failure and may result in significant harm to the machine operators including serious injury or death. • The AUX output, error output, muting state output, alert output, Clear/Blocked state output and inter-lock-reset-ready output cannot be used as safety outputs for the safety related control systems. Usage of these functions as safety outputs may result in significant harm to the machine operators, including serious injury or death. • The wait input is not allowed to be connected to the output from any components comprising a part of the safety related machine control system. If the wait input is connected to the output of a safety component it may result in significant harm to the machine operators, including serious injury or death. • Use the GL transmitter cable and receiver cable connected to the GL-T11R with the length specified in this instruction manual or shorter. Usage of cables longer than the specified length may cause improper operation of safety functions and may cause a dangerous situation. • For connection between GL-T11R and GL, make sure to use the dedicated cable for GL-T11R for correct connection. If using a wrong cable or connecting cables for the transmitter and receiver wrongly, FSD may be always ON. This is dangerous. GL-T11R-IM-E • You must always perform the pre-check test, in accordance with the pre-check test procedures, after maintenance, adjustment or alignment of the target machine or the GL-T11R and before the machine startup. • If the GL-T11R does not operate properly when you perform the pre-check test according to the pre-check test procedures specified in this instruction manual, do not operate the machine. • You must periodically examine the machine to verify that all brakes, other stop mechanisms, and control devices operate reliably and correctly in addition to checking the GL-T11R. • The responsible personnel must perform maintenance procedures as specified in this instruction manual to avoid any hazardous situation. • If the GL is in an error condition with the EDM error, the relay inside the GL-T11R may have a fault. In this case, replace the relay board according to "Replacing the relay board" of page 6. Precautions for regulations and standards ■ CE Marking KEYENCE has confirmed that the GL-T11R complies with the requirements of EC Directives under the conditions that the following requirements are satisfied. Note the following requirements when using the GL-T11R in EU countries. ● EMC Directive (2004/108/EC) • Applicable standards EMI : EN55011, Group 1, Class A EMS: EN61496-1 However, these requirements do not guarantee that the whole mechanical device into which the GL-T11R is incorporated satisfies the essential requirements of EMC Directives. A manufacturer of such a device has the responsibility to confirm the conformity of the whole mechanical device. ● Machinery Directive (2006/42/EC) The GL-T11R is a "safety component" defined in the EU Machinery Directive (2006/42/EC) Annex V. The GL-T11R complies with the following EN standards and has obtained the third-party certificate by TÜV SÜD Product Service GmbH. • Applicable standards EN61496-1, Type 4 ESPD EN50178 EN ISO13849-1, Category 4, PLe • Use a power supply that provides SELV or PELV output defined in EN50178. ■ UL Certification and Regulations in North America The GL-T11R has obtained the following UL/c-UL certifications: • UL File No. E184802 • Category NIPF/NIPF7 Note the following requirements when using this product as a UL certified product. • Use a power supply that provides Class 2 output defined in NEPA70 (NEC: National Electrical Code) in U.S.A. The GL-T11R also complies with the following regulations in North America. • FCC Part 15B, Class A Digital Device • ICES-003, Class A Digital Apparatus ■ Other applicable standards The GL-T11R has been designed in consideration of the following standards and regulations. For details regarding the following standards, contact the third-party certification organization, such as UL or TÜV. • EN60204-1 • EN692 • EN693 • OSHA 29 CFR 1910.212 • OSHA 29 CFR 1910.217 • ANSI B11.1 - B.11.19 • ANSI/RIA R15.06 - 1999 • SEMI S2 • "Guidelines for Comprehensive Safety Standards of Machinery", July 31, 2007, number 0731001 issued by Ministry of Health, Labor, and Welfare in Japan. 2 ■ Checking the Package Contents Indicators Name GL-T11R........................................................×1 Instruction Manual (this document)..........×1 Cable Point ■ Be sure to use the following cables for the connection between the GL-R and the GL-T11R. The GL-T11R does not operate when combined with other GL-R cables. GL-R Series Model (Transmitter/receiver set) φ5.8 45 φ17 31.5 M14 connector, male Length GL-RPT03PM 0.3 m GL-RPT3PM 3m GL-RPT5PM 5m φ5.8 44 FSD ON Green Lights when FSD turns ON FSD OFF Red Lights when FSD turns OFF ERROR Red Lights when an error condition occurs*1, *2 MUTE 1 Orange Lights when muting input 1 turns ON*1 MUTE 2 Orange Lights when muting input 2 turns ON*1 RESET Orange Lights when reset input turns ON WAIT Orange Lights when wait input turns ON*1 EDM Orange Lights when EDM input turns ON O-RIDE Orange Lights when override input turns ON*1 ■ DIN rail Mounting 1 Model Push hook B down with a screwdriver to release the lock mechanism. (Front View) Length (Transmitter/receiver set) 45 φ17 φ17 GL-RCT10PM 10 m M14 connector, male M14 connector, female ■ Lights when power is supplied Installation ● Extension cable Shape Description Green *1 When GL-R Series functions are switched using the Safety Device Configurator setting software, indicators light up according to each function’s input status. *2 For the GL-S Series, this indicator is fixed to being off. ● Unit connection cable Shape Light color POWER GL-S Series ● Unit connection cable Shape φ4 Model (Transmitter/receiver set) 45 φ17 M14 connector, male Hook B Length GL-SPT3P 3m GL-SPT5P 5m GL-SPT10P 10 m 2 3 Hook A * Push the main unit and latch hook B. DIN rail ● Extension cable Shape φ5.8 44 Model (Transmitter/receiver set) 45 φ17 φ17 M14 connector, female * Hook A latches on DIN rail Length GL-RCT10PM Hook B 10 m Hook B M14 connector, male 4 Part Names [Locked state] [Unlocked state] Hook A TR Transmitter connector Receiver connector POWER FSD-ON Indicator FSD-OFF RESET WAIT EDM ERROR O-RIDE MUTE1 MUTE2 Hook B *Position hook B so that it is locked. Removing from DIN rail Relay output terminal block (Front View) Signal input/output terminal block DIN rail CAUTION Electrical hazard Side Push down using a screwdriver. Rear Hook B SL-U2, mounting holes DIN rail mating area DIN rail lock pin SL-U2 connector *Covered by tape at time of shipment. 3 GL-T11R-IM-E ■ Screw Mounting The two mounting holes are used to install the GL-T11R with two M4 screws. (Recommended tightening torque: 0.7 N•m) Connection to the GL 2-φ4.2 (mounting hole) Transmitter Connector (grey) Receiver Connector (black) Receiver cable (Black connector end) 124 37 Point Transmitter cable (Gray connector end) Always leave at least 30 mm of open space between the GL-T11R and other equipment or walls. Cable Specification 30mm 30mm (1) Cable length z GL-R Series When using the main unit connection cable and the extension cable together, the total length of the combined cables must be 30 m or less for the transmitter and receiver respectively. z GL-S Series When using the main unit connection cable, the extension cable and the linking cable, the total length of the combined cables must be 20 m or less for both the transmitter and receiver. GL-T11R 30mm * When using the SL-U2, position the SL-U2 at least 30 mm from the edge of the cabinet. Connection to the SL-U2 Recommended Power Supply The power can be supplied by connecting to the SL-U2 dedicated power source via the connector on the side. DANGER *Install while being careful of the connectors Cables must be within the lengths specified. Failure to follow this specification may cause improper operation of the safety functions and may cause a dangerous situation. (2) Minimum cable bending radius : 5 mm (10 mm for the part where the connector to the GL-T11R is attached) (3) Identification of connector cables Types can be distinguished by the color of the connector end. Connector end Cables for Transmitter: Gray connector end Cables for Receiver : Black connector end 1 Remove the seal on the side of the GL-T11R that protects the connector port. 2 [For DIN rail mounting] • Mount the GL-T11R and the SL-U2 to the DIN rail, and slide together to couple the connectors. [For screw mounting] • Couple the connector according to the figure above. 3 Slide the SL-U2 connection hook to secure it to the GL-T11R. Reference Point When not using the SL-U2, connect a power source to the power input terminals found on the relay output terminal block. "Wiring Example" (page 6) GL-T11R-IM-E 4 Be sure to connect the unit connection cable for the receiver to the GL receiver and the unit connection cable for the transmitter to the GL transmitter. ■ Wiring Wiring method (1) Wiring the Relay Output Terminal Block Under factory default settings, shorting bars are connected between terminals 8 and 9, and terminals 10 and 11. Push in the orange projection using the flat-head screwdriver. Insert the cable. ■ GL-R Series The GL-R Series operates with the following settings under the factory default settings. • Interlock function: Not used (Auto reset mode) • EDM function: Not used If a setting change is not necessary, use as it is. For details of each function, refer to the "GL-R User’s Manual". ■ GL-S Series The GL-S Series operates with the following settings under the factory default settings. • EDM function: Not used Not all of the input/output functions assigned to the signal input/output terminals can be used. Use the signal input/output terminals with the factory default settings. • Connectable cable : AWG24 to 12 (single wire, stranded wire) • Connectable wire ferrule diameter: 1.3 - 2.6mm • Cable strip length: 10 mm (2) Wiring the Signal Input/Output Terminal Block POWER RESET FSD-ON WAIT FSD-OFF EDM ERROR O-RIDE MUTE1 MUTE2 Insert the cable. Insert the flat-head screwdriver to the square hole. Relay output terminal block Signal input/output terminal block CAUTION Electrical hazard ■ • Connectable cable : AWG24 to 12 (single wire, stranded wire) • Connectable wire ferrule diameter: 1.3 - 2.1mm • Cable strip length: Input/Output assignment Signal input/output terminal block (GL-R Series only) Relay output terminal block No. Name 10 Reset input (24V) No. 11 Reset input 2 12 Interlock selection input (24V) 3 13 Interlock selection input 4 14 AUX output 5 FE 15 Error output 6 0V 16 Muting lamp output 7 24V (input)* 1 Name NOTICE Internal circuit diagram FSD2 Muting input 1 8 EDM input (24V) 18 Muting input 2 9 EDM input 19 Wait input 20 Override input 21 0V Reference Do not perform pre-tinning on the cable end. FSD1 17 Point 10 mm GL-R main unit Relay unit Receiver No. Name 1 OSSD2 2 Not used 3 OSSD1 4 Reset input*1 5 Synchronization 1 (RS485+) 6 Synchronization 2 (RS485-) 7 24V 8 AUX output*1 9 EDM input 10 0V 11 Interlock selection input*1 12 FE*1 * Power supply terminal for GL-T11R. Do not connect when the SL-U2 power source is connected to the side of GL-T11R. For the GL-R Series, the functions are switched to different functions according to the settings configured with the "Safety Device Configurator" PC setting software. When the settings are changed, check the wiring referring to the internal circuit diagram in the next section. K1 K2 K1 Transmitter No. Name 1 Wait input*1 2 Not used 3 Override input*1 4 Error output*1 5 Synchronization 1 (RS485+) 6 Synchronization 2 (RS485-) 7 24V 8 Muting lamp output*1 9 Muting input 2*1 10 0V 11 Muting input 1*1 12 FE*1 For the GL-R Series, the power source can be supplied to the muting device or muting lamp from each 24V terminal. (The total supply current is 95mA or less. The voltage decreases by approx. 1V from the voltage input to GL-T11R.) K2 Relay output terminal block No. Name 1 FSD1 2 3 FSD2 4 5 6 7 8 9 FE*1 0V 24V (input) EDM input (24V) EDM input Signal input/output terminal block*1 No. Name 10 Reset input (24V) 11 Reset input 12 Interlock selection input (24V) 13 Interlock selection input 14 AUX output 15 Error output 16 Muting lamp output 17 Muting input 1 18 Muting input 2 19 Wait input 20 Override input 21 0V *1 These functions cannot be used with the GL-S. Reference M14 connector male pin array 2 3 4 5 1 10 9 12 11 8 5 7 6 M14 connector female pin array 1 9 8 2 10 3 11 12 4 7 5 6 GL-T11R-IM-E Wiring Example ■ Replacing the Relay Board The relay used for the FSD of the GL-T11R can be replaced without rewiring the connection terminal. GL-R Series This wiring example illustrates the case of the following settings. • Interlock function: Used (Manual reset mode) • EDM function: Used • Muting function: Used Relay output terminal block Name FSD1 FSD2 FE 0V*1 24V (input)*1 EDM input (24V)*2 EDM input*2 No. 1 2 3 4 5 6 7 8 9 1 2 F1 F2 K3 K4 K4 K3 3 Prepare the relay board for the GL-T11R (OP-87682). Turn off the power to the GL-T11R and all the devices connected to the GL-T11R. Loosen the two terminal replacement screws, and remove the relay output terminal block. Relay output terminal block K3 Signal input/output terminal block Name No. 10 Reset input (24V) *3 11 Reset input*3 Interlock selection input (24V) 12 Interlock selection input 13 AUX output 14 Error output 15 Muting lamp output 16 Muting input 1 17 Muting input 2 18 Wait input 19 Override input 20 0V 21 K4 M S1 L1 S2 S3 Brown Black P1 Blue Brown Black P2 Blue 4 Loosen the two relay board replacement screws and remove the current relay board from the GL-T11R. Relay board for the GL-T11R PLC GL-S Series FSD2 Not used 0V*1 24V (input)*1 EDM input (24V)*2 EDM input*2 ■ No. 1 2 3 4 5 6 7 8 9 F1 F2 K3 K3 K4 K4 K3 K4 5 6 M 7 Meaning of symbols F1, F2 K3, K4 S1 S2 S3 L1 P1, P2 M PLC : : : : : : : Fuse External device (Magnet contactor, etc.) Switch for reset (N.O.) Switch for wait input (N.O.) Switch for override (N.O.) Muting lamp (Incandescent lamp or LED lamp) Muting device (Photoelectric sensors with built-in amplifiers such as PZ (PNP output), etc.) : 3-phase motor : For monitoring use. This is a NON-SAFETY RELATED system. Install the new relay board in the GL-T11R and tighten the relay board replacement screws. (Recommended tightening torque: 0.3 N•m) Attach the relay output terminal block to the relay board and tighten the terminal replacement screws. (Recommended tightening torque: 0.3 N•m) Check the operation according to the checklist. External Dimensions Diagram (112) S2 and PLC are NON-SAFETY RELATED systems. No. 6 and No. 7 do not need to be wired when the SL-U2 is connected. If it is not necessary to perform error detection for K3 and K4 (when EDM input is not used), use the shorting bar between No. 8 and No. 9. In the auto reset mode, use the shorting bar between No. 10 and No. 11. To release the error condition of a GL-R through the reset input, connect a N.C. switch. Point • For the GL-R Series, the functions are switched to different functions according to the settings configured with the "Safety Device Configurator" PC setting software. When the settings are changed, check the wiring referring to the internal circuit diagram in the previous section. • The total electric current supplied from each 24 V terminal of the GL-T11R must be 95 mA or less. GL-T11R-IM-E (16) 48 2xφ4.2 11 23 49.8 *3 3.5 35.9 *1 *2 (100.7) 83.8 23 FSD1 135 Relay output terminal block Name 124 ■ IN 37 6 Specifications Response Time for Combination Between GL and GL-T11R Model The following are the response times for the combination between GL and GL-T11R. A) Maximum response time when the FSD goes to the OFF state after the GL detects an interruption in the detection zone. The response time* (ON to OFF) of the GL connected to GL-T11R + 10 ms B) Maximum response time when the FSD goes back to the ON state after the GL detects no interruption in the detection zone. The response time* (OFF to ON) of the GL connected to GL-T11R + 32 ms GL-T11R Supported model GL-R Series/GL-S Series 250 V AC, 6 A 30 V DC, 6 A (Resistance load) Relay output FSD1, 2 240 V AC, 2 A (COSφ=0.3) (Inductive load) 24 V DC, 1 A (COSφ=0.3) (Inductive load) Response time ON → OFF GL + 10 ms OFF → ON GL + 32 ms 100,000 cycles or more with 250 V AC, 6 A Resistance load (Open/Close frequency 20 times/min.) * For details on the response time, refer to the GL-R user's manual or the GL-S user's manual. 100,000 cycles or more with 30 V DC, 6 A Resistance load (Open/Close frequency 20 times/min.) Life-span Electrical lifespan 500,000 cycles or more with 250 V AC, 1 A Resistance load (Open/Close frequency 30 times/min.) The following are examples of total response times in cases where the GL-T11R is connected to the GL with the series-connection cable. When connecting the GL-R32H (32 beam axes), GL-R24H (24 beam axes), and GL-R12L (12 beam axes) in series, the response time of each unit is 7.9 ms, 7.0 ms, and 6.6 ms respectively. The response time (ON to OFF) is 7.9 + 7.0 + 6.6 - 4.2* + 10 = 27.3 ms and the response time (OFF to ON) is 50.6 + 49.3 + 48.7 - 84* + 32 = 96.6 ms 500,000 cycles or more with 30 V DC, 1 A Resistance load (Open/Close frequency 30 times/min.) AC15: 100,000 cycles or more with 240 V AC, 2 A Inductive load (Open/Close frequency 20 times/min., cosφ=0.3) DC13: 100,000 cycles or more with 24 V DC, 1 A Inductive load (Open/Close frequency 20 times/min., L/R=48ms) AUX output*1 Non-safety output Error output*1 Muting lamp output*1 EDM input Wait input*1 External input Reset input*1 Muting input 1, 2*1 Override input*1 Power source * When calculating the response time of the GL-R using two connected sub units, sum the response time of all three GL-R and then subtract 4.2 ms (ON to OFF) or 84 ms (OFF to ON). For more detail, refer to the GL-R user’s manual. Transistor output (Connectable to PNP/NPN input device)*2 50mA or less, Residual voltage 2.5 V or less (When the cable length between GL-R and GL-T11R is 5 m) ■ Time Chart FSD Incandescent lamp (24 V DC, 1 to 5.5 W) Connectable to LED lamp (Load current 10 to 230 mA) ON OSSD of GL [GL-R Series] ON voltage: [Power source voltage - 5 V] to [Power source voltage] OFF voltage: Open or 0 to 3 V Short-circuit current: Approx. 2.5 mA (EDM input only approx. 10 mA) [GL-S Series] Short-circuit current (EDM input): Approx. 1 mA OFF ON FSD 24 V DC ± 10%, Ripple (P-P) 10% or less, Class2 Consumption current 100mA or less (at 24 V DC, GL-T11R alone) Enclosure rating IP20 (IEC60529) Install inside a control panel of IP54 or greater Pollution degree 2 OSSD of GL Storage ambient humidity Material FSD EDM input -10 to +55 °C (No freezing) 2000 m or less Vibration Shock 100 m/s2 (Approx. 10 G) 16 ms pulse, 1,000 times each in X, Y, and Z directions Main unit case 10ms 32ms 10ms ON Specified period of time 0.3 s* Specified period of time 0.3 s* (1) The normal operation continues because FSD operates within the permissible time (0.3 sec.) according to the OSSD operation of GL. (2) The GL enters an error condition as "EDM error" because FSD does not operates within the permissible time (0.3 sec.). * For the GL-R Series, the time can be changed using the Safety Device Configurator. 15 to 85% RH (No condensation) 10 to 55 Hz 0.7 mm compound amplitude, 20 sweeps each in X, Y, and Z directions Error condition ON OFF -25 to 60 °C (No freezing) Elevation ON OFF 15 to 95% RH Weight 32ms OFF Overvoltage category Storage ambient Environment temperature resistance Ambient humidity 10ms When EDM input is used Power source voltage Ambient temperature OFF Polycarbonate Approx. 310 g EMC Applicable standard EMS EN61496-1, UL61496-1, IEC61496-1 EMI EN55011 ClassA, FCC Part15B ClassA, ICES-003 ClassA EN61496-1, UL61496-1, IEC61496-1 (Type 4 ESPE) Safety EN ISO13849-1: 2008 (Cat4 PL e) UL508, EN50178 * For operations of each function and detailed specifications, refer to the "GL-R User’s Manual" or "GL-S User’s Manual". *1 When connected to the GL-S Series, these functions cannot be used. *2 The output operation is the same as that when the PNP output type cable is used. 7 GL-T11R-IM-E ■ Checklist When the installation and wiring of the GL and the GL-T11R are completed, the responsible personnel must verify operations in accordance with the checklist shown below. The following checklist covers the minimum requirements for the GL-T11R. The check items required may vary depending on the machine where the GL-T11R is installed, and the laws, rules, regulations and standards in the country or region in which the GL-T11R will be used. KEYENCE strongly recommends that other necessary check items should be added by the responsible personnel for the use of the GL-T11R. This checklist only lists the items related to the GL-T11R, so refer to the GL-R instruction manual or the GL-S instruction manual to create a checklist that also covers the GL. ■ Inspection as needed In the following cases, perform inspection for all items. • When the unit is installed for the first time • When the parts and wires relating to this system are replaced or changed • When an abnormal operation is found WARRANTIES AND DISCLAIMERS (1) KEYENCE warrants the Products to be free of defects in materials and workmanship for a period of one (1) year from the date of shipment. If any models or samples were shown to Buyer, such models or samples were used merely to illustrate the general type and quality of the Products and not to represent that the Products would necessarily conform to said models or samples. Any Products found to be defective must be shipped to KEYENCE with all shipping costs paid by Buyer or offered to KEYENCE for inspection and examination. Upon examination by KEYENCE, KEYENCE, at its sole option, will refund the purchase price of, or repair or replace at no charge any Products found to be defective. This warranty does not apply to any defects resulting from any action of Buyer, including but not limited to improper installation, improper interfacing, improper repair, unauthorized modification, misapplication and mishandling, such as exposure to excessive current, heat, coldness, moisture, vibration or outdoors air. Components which wear are not warranted. (2) KEYENCE is pleased to offer suggestions on the use of its various Products. They are only suggestions, and it is Buyer's responsibility to ascertain the fitness of the Products for Buyer’s intended use. KEYENCE will not be responsible for any damages that may result from the use of the Products. (3) The Products and any samples ("Products/Samples") supplied to Buyer are not to be used internally in humans, for human transportation, as safety devices or fail-safe systems, unless their written specifications state otherwise. Should any Products/Samples be used in such a manner or misused in any way, KEYENCE assumes no responsibility, and additionally Buyer will indemnify KEYENCE and hold KEYENCE harmless from any liability or damage whatsoever arising out of any misuse of the Products/Samples. (4) OTHER THAN AS STATED HEREIN, THE PRODUCTS/SAMPLES ARE PROVIDED WITH NO OTHER WARRANTIES WHATSOEVER. ALL EXPRESS, IMPLIED, AND STATUTORY WARRANTIES, INCLUDING, WITHOUT LIMITATION, THE WARRANTIES OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE, AND NON-INFRINGEMENT OF PROPRIETARY RIGHTS, ARE EXPRESSLY DISCLAIMED. IN NO EVENT SHALL KEYENCE AND ITS AFFILIATED ENTITIES BE LIABLE TO ANY PERSON OR ENTITY FOR ANY DIRECT, INDIRECT, INCIDENTAL, PUNITIVE, SPECIAL OR CONSEQUENTIAL DAMAGES (INCLUDING, WITHOUT LIMITATION, ANY DAMAGES RESULTING FROM LOSS OF USE, BUSINESS INTERRUPTION, LOSS OF INFORMATION, LOSS OR INACCURACY OF DATA, LOSS OF PROFITS, LOSS OF SAVINGS, THE COST OF PROCUREMENT OF SUBSTITUTED GOODS, SERVICES OR TECHNOLOGIES, OR FOR ANY MATTER ARISING OUT OF OR IN CONNECTION WITH THE USE OR INABILITY TO USE THE PRODUCTS, EVEN IF KEYENCE OR ONE OF ITS AFFILIATED ENTITIES WAS ADVISED OF A POSSIBLE THIRD PARTY’S CLAIM FOR DAMAGES OR ANY OTHER CLAIM AGAINST BUYER. In some jurisdictions, some of the foregoing warranty disclaimers or damage limitations may not apply. Inspection after installation When the installation of the GL-T11R is completed, the responsible personnel must verify the operation of the GL-T11R in accordance with the checklist shown below. The checklist below covers the minimum requirements for the GL-T11R. The check items required may vary depending on the machine on which the GLT11R is installed and the laws, rules, regulations and standards in the country or region in which the GL-T11R will be used. KEYENCE strongly recommends that other necessary check items should be added by the responsible personnel for the use of the GL-T11R. (1) Pre-check for installation condition ❑ The machine on which the GL-T11R is installed can stop when it receives the FSD output from the GL-T11R. ❑ The interlock reset mechanisms (such as switches) are installed so that the whole hazardous zone can be checked by the responsible personnel and that operations of the interlock reset mechanisms are not possible within the hazardous zone. ❑ The GL-T11R is installed in an enclosure of IP54 or greater. ❑ The DIN rail is fixed on the control panel (enclosure) with adequate strength to support the weight of the GL-T11R. ❑ Space is ensured around the GL-T11R for ventilation or heat release as specified in this manual. ❑ The installation of the GL-T11R fulfills conditions specified in this instruction manual and the requirements of the laws, rules, regulations and standards in the country or region where the GL-T11R is used. (2) Pre-check for wiring ❑ To supply power to the GL-T11R, the SL-U2 power supply recommended by KEYENCE is used, or a different 24 VDC power supply that satisfies the power supply conditions specified in this instruction manual is used. ❑ The cable for transmitter (Gray M14 connector end) is connected to the cable connector for transmitter, and the cable for receiver (Black M14 connector end) is connected to the cable connector for receiver. ❑ The safety related machine control system is established by using both of the safety outputs provided on the GL-T11R. ❑ The polarity is correct for connection to the power supply. ❑ The wait input is not connected to the output from the safety components comprising a part of the safety related machine control system. ❑ Non-safety related outputs are not used as a part of the safety related control system. ❑ Wiring is performed in a manner that complies with the requirements of Clause 9.4.3 in IEC60204-1:2005 in order for the protection against malopeation due to earth fault. BUYER'S TRANSFER OBLIGATIONS: If the Products/Samples purchased by Buyer are to be resold or delivered to a third party, Buyer must provide such third party with a copy of this document, all specifications, manuals, catalogs, leaflets and written information provided to Buyer pertaining to the Products/Samples. E 1101-3 Document Control No. 981BE151-01 ■ Regular (periodical) inspection The responsible personnel must perform a regular inspection. It is recommended to perform a regular inspection at least once every six months. Note that the following inspection items comprise only a bare minimum inspection. KEYENCE Corporation strongly recommends including the necessary checking items into this checklist based on the judgment of the responsible personnel since additional criteria may be necessary depending on both the machine to which the GL-T11R is installed and the laws, rules, regulations and standards in the country or region in which the GL-T11R is used/installed. The result of this inspection must be kept on record along with the machine log. ❑ Conductive contamination does not occur due to oil or dust adherence. ❑ The response time of the whole machine control system is below the design value and normal. ❑ Devices with a finite lifetime such as switches, relays or contactors are still functional. ❑ Wiring is correctly performed and no modifications or connection changes are made that may adversely affect the safety related system of the equipment. ❑ There are no disconnected or loose wires on the connection terminal. ❑ The open/close cycle of the FSD is within the lifespan. If needed, replace it by referring to "Replacing the Relay Board". 2013 GL-T11R-IM-E 8 12530E 1053-1 96M12530