Uploaded by Manu Romero

Sumflex® BS 1000V en Rev.0

advertisement
Sumcab Specialcable Group
PI Pla de Llerona - C/ Gran Bretanya 28
08520 Les Franqueses del Vallès
Barcelona І Spain І European Union
www.sumcab.com І sumcab@sumcab.com
The information contained in this document must not be copied, reproduced or reproduced in any form, in whole or in part, without the written consent of Sumcab. The information is believed to be correct at
the time of issuance. Sumcab reserves the right to modify this specification without prior notice. This specification is not contractually valid unless specifically authorized by Sumcab. All product values shown
are nominal values unless otherwise specified. Images are not to scale and should not be considered faithful representations of the respective products. Our products are compliant to RoHS Directive
2011/65/EU of the European Parliament and the Council from 08/06/2011 on restriction of the use of certain hazardous substances in electrical and electronic appliances.
Product Information
Sumflex® BS 1000V
TDS Reference:
Rev.:
Date:
Creator:
SumflexBS1000V
0
24/04/2023
C01/MRR
Application
Highly flexible power cable for the connection of submersible pumps. Jacket with very low water absorption, suitable for depths up to 50m.
High abrasion and tear resistance. Superior mechanical strength. Mobile use.
Design
Conductor:
Tinned copper wires, stranded
Class 5 according to IEC 60228
EPR
3G = blue, brown, yellow/green
4G = brown, black, grey, yellow/green
4G+2C = 4G brown, black, grey, yellow/green
2C white with black color marked T1, T2
5G = brown, black, grey, blue, yellow/green
Insulation:
Wire Identification:
Tecnical Data
Inner sheath:
Outer sheath:
Color:
Marking:
Rubber 5GM5
Rubber 5GM5
Black
Sumflex® BS 1000V "Nº Cond." G "NN"mm² CE
"Year" "Batch" "NN"m www.sumcab.com
Standards & other Properties:
Working Voltage:
Test Voltage:
Temperature Range:
600V / 1000V
3.500V
-40ºC up to +70ºC (fixed installation)
-5ºC up to +70ºC (mobile use)
+90ºC (250ºC @ Short-Circuit)
5 x Outer diameter (fixed installation)
7,5 x Outer diameter (mobile use)
Max. Conductor temp.:
Min. Bending Radius:
Nº cond. x mm²
3 G 1,5
4 G 1,5
4 G 2,5
4G4
4G6
4 G 10
4 G 16
4 G 25
4 G 35
4 G 50
4 G 70
4 G 95
4 G 120
Outer diameter Nominal current
(mm)
capacity (Amp)
10,0 - 11,0
10,5 - 11,5
12,5 - 13,5
16,0 - 17,0
18,0 - 19,0
23,5 - 25,5
26,0 - 28,0
32,5 - 34,5
36,5 - 38,5
41,0 - 45,0
45,0 - 49,0
54,0 - 58,0
56,0 - 60,0
23
23
32
42
54
75
100
127
157
192
246
298
346
EN 50525-2-21
HD.2216 & VDE 0298-300
IEC 60245
IEC 60332-1
VDE 0298
VDE 0250
VDE 0472 part 803-A
Nº cond. x mm²
4 G 1,5 + 2 X 1,5
4 G 2,5 + 2 X 1,5
4 G 4 + 2 X 1,5
4 G 6 + 2 X 1,5
4 G 10 + 2 X 1,5
4 G 16 + 2 X 1,5
4 G 25 + 2 X 1,5
4 G 35 + 2 X 1,5
Product is CE & RoHS conform
Cables for submersible use
Permanent use in water
General
Flame retardant
Current
Material
Oil resistant
Outer diameter Nominal current
(mm)
capacity (Amp)
15,0 - 16,0
17,0 - 18,0
20,0 - 22,0
23,0 - 25,0
26,0 - 28,0
26,0 - 28,0
32,5 - 34,5
36,5 - 38,5
23
32
42
54
75
100
127
157