Do not scale from this drawing. All dimensions are to be checked and verified on site and all discrepancies reported to 5PA Architects Ltd prior to any construction work taking place. This drawing is the property and copyright of 5PA Architects Ltd and cannot be reproduced without permission. The contractor shall allow for all materials and work necessary to complete the works as intended whether indicated or not on specifications or drawings. DRAWING TO BE PRINTED IN COLOUR This drawing may incorporate information from other professionals. 5PA cannot accept responsibility to the integrity and accuracy of such information. Any clarification and/or additions that are required appertaining to such information should be sought from the relevant profession or their appointment. 160mm (100mm + 60mm) Rockwool Duoslab or similar approved insulation fastened back to substrate using Ejot JT3 D6H 5.5/6.3 self drilling screws and DMT 85/7E washers or similar approved, setting out to comply with Rockwool's requirements - NBS Section F30, Clause 155A 59.5 12.5 160 100 Vedex Zedex Non-Combustible DPC cavity tray installed strictly in accordance with manufactures/warranty providers guidance. Secure Visqueen Joint Support at lap joint location, apply Visqueen Mastic along substrate to adherer Visqueen Zedex Non-Combustible DPC cavity tray and then install Visqueen Non-Combustible fixing strip using s/s mechanical fixings suitable for substrate. For additional guidelines refer to manufacturers / warranty providers requirements for Building Control approval - NBS Section F30, Clause 320 Allow for brick reveal support plates to all 215mm window jamb reveals. For brick reveals greater than 215mm refer to drawing XXX for ancon masonry support. Fire sealant only required to gaps / joints greater than 5mm. Waterproofing and insulation to be installed to manufacturers recommendations. Drawings to be read in conjunction with IKO's specialists details. Rainscreen cladding to be water tested by independent UKAS accredited body. Any apertures in cladding, soffit boards, reveals and jambs greater than 10mm should have insect mesh applied whether shown on the drawings or not. Insect mesh generally indicated as 2 No. layers of 12.5mm Siniat GTEC dB Board, tape and staggered joint finish. Each layer to be independently fixed to SFS to limit effects of flanking sound transmission All products to be fully compatible with each other and to be installed in accordance with the products own BBA certification. All brickwork/cladding structural fixings must be fixed directly to structure. TYPICAL COLUMN EXTENT, SHOWN IN DISTANCE 165 150 MIN Blockwork coursing shown indicatively. Specialist sub-contractor to ensure blockwork courses throughout and within BS guidelines. All cavity trays and DPC's to be installed in accordance with BS 8215:1991 whether shown on the drawings or not and compliant to the current ADB. Membranes used as part of the external wall construction should achieve a minimum classification of European Class B-s3, d0. Slip sheet to be applied on top of waterproofing and under brickwork and to extend a minimum 200mm from face of brickwork, to manufacturers details. Blockwork behind waterproofed upstand, cut blocks as required to suit coursing - NBS Section F10, Clause 355C Any metalwork within façade that sits outside the VCL/EPDM line to be stainless steel, any metalwork behind the VCL/EPDM line to be GMS. All EPDM's to be Obex Cortex or similar approved and achieve a minimum classification of European Class B-s3, d0. See NBS Section P10, clause 315 152.5 IKO PermaGUARD M protection layer 62.5 90 Rockwool Hardrock Multi-Fix angle fillet with adhesive fixing to horizontal slab edge, prior to EPDM seal between sheathing and concrete 82 Fire Barrier rating/spec may vary dependant on location. Refer to 67 Series Fire Strategy Elevations Polyester Powder Coated to be AkzoNobel Interpon D2000 series Class A2,s1-d0 in accordance with BS EN 13501-1. See NBS Section Z31 SFS stud channel fixed securely to concrete, resin bonded or similar to create watertight junction with waterproof membrane, all to specialists details Siderise Cavity barriers as NBS Section P12, Clauses 360 PRECISE WINDOW AND DOOR SETTING OUT TBC ONCE WINDOW SYSTEM/MANUFACTURER IS CONFIRMED DPC laid across top of upstand under SFS track and turned down inside face of upstand by minimum 150mm. DPC to link to VCL 150 DETAIL SHOWN IS A TYPICAL SCENARIO THAT OCCURS ACROSS THE SCHEME, THEREFORE THERE MAY BE VARIANCES OF THIS DETAIL. PLEASE REFER TO 04 SERIES GA PLANS, 05 SERIES ELEVATIONS & 06 SERIES SECTIONS. PLEASE NOTE THAT THIS DRAWING IS TO BE USED FOR TENDER PURPOSES ONLY. THIS DRAWING HAS NOT BEEN COORDINATED WITH RELEVANT SPECIALISTS. Foamglas T4+ or similar approved non combustible insulation in wet areas, taped and sealed against concrete upstand to manufacturers recommendations - NBS Section F30, Clause 150B 1mm gauge 40x14x40mm 'Z' galvanized mild steel angle to fix plasterboard to upstand at 600mm vertical centres 300 15 15mm floor finish zone 55mm 'Gyvlon' or similar anhydrate screed system, incorporating underfloor heating pipework, on 1200 gauge polythene sheet tucked up to top of screed - NBS Section M13, Clause 120 80 55 FOR UPSTAND HEIGHTS SEE DRAWING 9615-A-C-11-27-200 25mm Kingspan TF70 Thermafloor high performance rigid thermoset insulation NBS Section M13, Clause 260E 25 150 177 Where materials are being fixed and mixed i.e aluminium with stainless steel; please use isolating washers or good quality butyl tape to avoid bi-metallic corrosion. All galvanised items to have a micron coating of no less than 60μm. EPDM dressed over waterproofing layer up to cavity tray level 300 First install of IKO permatec waterproofing system up to top of upstand level. PermaGuard-M additional layer applied to take brickwork leaf A row of brickwork ties to be installed at 450mm horizontal centres within four courses of masonry support angles. Please refer to SE drgs for further info All external walls below DPC to be engineered brickwork with class i mortar with sulphate resisting cement unless specified otherwise by Structural Engineer. Rytons Rytweep A1 metal fire-rated cavity weep vent or similar approved Part B of the Building Regulations compliant weep vent, at 900mm horizontal centres - NBS Section F30, Clause 132A FALLS STRATEGY SHOWN INDICATIVELY, FOR DESIGN INTENT/PRINCIPLE SEE DRAWING 9615-A-C-11-27-200 Masonry ties to be allowed for in accordance with British Standards and Building Regulations, whether shown on this drawing or not. Procheck FR 200 Vapour Control Layer (VCL) to be sealed at all laps, junctions and penetrations using tape recommended by manufacturer. Appropriate manufacturer recommended tape to fix to concrete / block / brick. VCL to approved by Building Control / LABC - NBS Section P10, Clause 310 100 MIN Ibstock Bradgate multi-cream brickwork with natural mortar - NBS Section F10, Clause 110 Permaflash D-150 reinforcement where minor movement or change in in materials occur 7.5mm overall of two coats of IKO Anti-Root incorporating PermaFLASH F reinforcement fleece and IKO PermaGUARD F protection layer. See 27 Series for further details For levels, refer to 05 Series Elevations and 06 Series Sections. 25 219.5 ROOF TYPE RF-01 / RF-02 FOR EXACT LOCATION REFER TO ROOF REFERENCE 9615-A-Z-RF-27-001 FOR PRECISE ROOF BUILD-UP, SEE ROOF & PODIUM BUILD-UP DRG. 9615-A-Z-M-27-001 12.5mm Siniat Weather Defence board or similar non combustible board with appropriate mastic jointing covered with 100mm wide EPDM bonded to surface All materials used within the facade to be Class A rated. If in doubt ask. 100mm EOS or similar approved SFS with studs at nominal 600mm centres to specialists details with 100mm Rockwool RWA45 or similar approved mineral fibre insulation within metal frame 459.5 102.5 Finish varies The sub-contractor (tenderer) to allow for all details & products to be constructed & installed strictly in accordance with the manufacturers details, specifications and relevant British Standards. This drawing is subject to final BC/ warranty provider approval. Ancon 25/14 brickwork restraint system or similar approved, comprising 25/14 channel fixed back to SFS studs at 600(h)x225(v)mm centres using HTSS-240-2PT-W self drill self tap fixings. SD25 ties x 150mm long at 300mm vertical centres on each stud NBS Section F30, Clause 245 2mm PPC flashing keyed into brickwork coursing and under DPC cavity tray to protect waterproof membrane as shown. Colour to match windows Tyvek Firecurb House wrap breather membrane blockwork, dressed over cavity tray - NBS Section P10, Clause 320 Foamglas Perinsul Block HL (A1 rated/non-combustible) with protection layer to protect from freeze thaw from wet zone where heated space below or similar approved thermal block to prevent cold bridging - NBS Section F30, Clause 185 C06 DPC membrane added as per LABC comments 14.11.22 Revisions 5PA CHARTERED ARCHITECTS 5PA Architects Ltd, 3 Southwark St, London, SE1 1RQ 10mm Yelofon E-Strip or similar acoustic flanking strip - NBS Section M10, Clause 295 Cavity backfilled with splayed top lean mix concrete Project TELFORD HOMES & CATALYST BY DESIGN CIW - BRENTFORD Title BLOCK C 11TH FLOOR ROOF WALL BASE DETAIL BRICK FACADE Revision Drawn by C06 5PA Drawing Status 19.07.22 C04 C03 C02 C01 01.07.22 11.04.22 01.04.22 24.01.22 C2 WATERPROOFING ISSUE C2 SFS ISSUE C2 BRICK & BLOCKWORK ISSUE General coordination Date 5PA JUL 20 Scale C2 ISSUE C05 amended to JWA and client comments Checked 1:5 @A3 Drawing Number 9615-A-Z-M-21-107