Uploaded by pbolsi

ELBT6-LFP-12V6AH-LiFePO4-Battery-Datasheet

advertisement
LITHIUM ION PHOSPHATE BATTERY
ELBT LiFePO4 series batteries offer BMS controlled safety, long
life,fast-charging performance(Optional Bluetooth function,which can
real-time Bluetooth Access to battery SOC,Voltage, Current,
Temperature status). The BMS embeds smart balancing algorithms
that control all cell voltages in the battery, making sure they are
constantly at the same voltage level, optimizing battery capacity.
ELECTRICAL SPECIFICATION
Nominal Voltage
12.8V
Nominal Capacity
6AH
Stored Energy
76.8Wh
Resistance
80 mΩ
Self Discharge Rate
<3% per Month
Maximum Continous Charge Current
6A
Maximum Continous Discharge Current
6A
Charge Cut-off Voltage
15.6 V
Discharge Cut-off Voltage
10V
Cycle life(25°C)
>4000 times@80%DOD
MECHANICAL SPECIFICATIONS
INTELLIGENT BMS FUNCTION

Overcharge detection function

Over discharge detection function

Over current detection function

Short detection function
Dimensions (mm)
L151×W65×H94

Temperature detection function
Weight
0.8kg

Balance function
Terminal Type
Outside F1 terminal
Case Material
ABS
Enclosure protection
IP64
Eclosure Protection
Enclosure Protection
BLUETOOTH® ENABLED
Monitor the State of Charge (SoC),
State of Health (SoH), current, capacity,
temperature, number of cycles, and
voltage levels of the battery and individual
TEMPERATURE SPECIFICATIONS
Discharge Temperature
0 to 55 °C
Charge Temperature
-10 to 55 °C
Storage Temperature
-20 to 60 °C
Eclosure Protection
Enclosure Protection
cells from APP.
OTHERS SPECIFICATIONS
Short Circuit Protection
Automatically recover after removal of short
Life Expectancy (years)
10 years at one cycle per day
Copyright © 2022 ELB. All rights reserved.
https://www.ecolithiumbattery.com/
BATTERY FEATURES
• Super safe lithium iron phosphate (LiFePO4) chemistry reducing the risk of
65mm
explosion or combustion due to high impact, over-charging or short circuit situation.
• Bluetooth® communication capability for battery status through ELB APP.
• Battery Management System (BMS) controls the parameters of the battery to
provide optimum safety by protecting against over-charging and over-discharging.
• BMS enhanced design balances the battery cells, optimizing battery performance.
151mm
• Delivers twice the power of lead acid batteries, even at high discharge rates, while
maintaining high energy capacity.
• Faster charging and lower self-discharge.
TERMINAL F1
• Up to 10 times more cycles than lead acid batteries.
94mm
Hole size:
W-1.5mm
H-2.5mm
• Compact and only 40% of the weight of comparable lead acid batteries.
PERFORMANCE CHARACTERISTICS
Voltage/V
Capacity/Percentage
110%
100%
90%
15.5
1C
15.0
0.9C
14.5
0.8C
14.0
80%
0.7C
13.5
70%
60%
50%
13.0
0.6C
12.5
0.5C
12.0
0.4C
40%
11.5
30%
11.0
20%
10.5
10%
10.0
0%
Charge Rate
16.0
120%
0%
20%
40%
60%
80%
0.3C
0.2C
0.1C
9.5
100%
0C
0%
20%
40%
Discharge voltage Characteristic at different Rate@25°C
Charging characteristic
80%
100%
Capacity/Percentage
(0.2C @ 25°C)
Voltage/V
Voltage/V
14.5
14.5
14.0
14.0
13.5
13.5
13.0
13.0
12.5
12.5
12.0
12.0
11.5
11.5
11.0
11.0
10.5
10.5
10.0
10.0
9.5
9.5
9.0
9.0
8.5
8.5
8.0
60%
8.0
0%
20%
40%
60%
80%
100%
0%
Capacity/Percentage
20%
Capacity of LiFePO4 vs. Lead acid@Different current of discharge
40%
60%
80%
100%
Capacity/Percentage
Discharge voltage Characteristic at different Temperature
Voltage/V
15.0
SOC
Capacity
14.5
/
100%
14.0
/
98%
/
96%
13.0
100%
94%
12.5
90%
92%
13.5
12.0
80%
90%
11.5
70%
88%
11.0
60%
86%
50%
84%
10.0
40%
82%
9.5
30%
80%
20%
78%
10%
76%
0%
74%
10.5
9.0
8.5
8.0
0
50
100
150
200
Charge voltage and SOC status @25°C
Copyright © 2022 ELB. All rights reserved.
250
300
350
0
2000
4000
6000
8000
Cycle life in Different DOD @25°C
https://www.ecolithiumbattery.com/
STANDARD CHARGE AND DISCHARGE
Standard Charge

Charge at 0.2C constant current until the battery reaches 14.6V. The battery then charges at constant voltage of 14.6V while tapering
the charge current. Charging will end when the current has tapered to 0.05C. The battery should be charged between 0°C and 45°C,
then rest for 30 minutes before discharging. Do not exceed the max charging current, voltage, or temperature limits as specified in this
document. Do not reverse-polarity charge the battery.
Standard Discharge

Battery should be discharged at a constant current of 0.2C to 10.0V at 20±5°C, then rest for 30 minutes before charging.
Storage

The batteries should be stored open circuit, and protected against the possibility of a short between the terminals. The battery should
be charged once every 6 months if not in use to prevent over-discharging. They batteries should be stored at room temperature, and
charged to 30-50% SOC.
Warnings

If the battery is over-charged and over-discharged too frequently, this will affect the long-term performance and capacity of the
battery. If the battery is stored for too long, reduced capacity and performance can be expected. It is important to cycle the battery at
least once every 6 months and stored at the appropriate SOC to prevent deterioration to the battery.
BATTERIES PARALLEL CONNECTION GUIDE
General positive
General negative
PARALLEL CONNECTION GUIDELINES
CAUTION:

Severe damage to the battery, short circuiting and sparking will happen if the batteries are not connected correctly or properly
maintained. We recommend assembly be completed by fully trained professionals only.

Do not reverse connect the anode and cathode, as this will damage the batteries and/or any equipment connected.

DO not connect the batteries in parallel AND series at the same time.
Before install

Ensure wires can withstand twice the capacity rating of the battery. (Ex: ELBT6-LFP has a capacity of 6Ah, so the wire must be able to
withstand 12A.)

Charge all batteries with 14.6V per standard charge.

Ensure all batteries have the same voltage level by fully charging each battery prior to connecting in parallel. (Voltage difference
<0.2V)
Install

Make sure the connections are tight and the connector is protected from corrosion, wear, and seismic situations. Connecting
impedance <0.1mΩ

DO NOT connect more than 4 batteries per circuit.
Copyright © 2022 ELB. All rights reserved.
https://www.ecolithiumbattery.com/
Maintenance

Make sure capacity stays within 50-60% when storing the batteries. The temperature should be 0-35 °C, humidity 75-85% and fully
charged every 3 months and discharged to 50-60% capacity.

Once a year, the batteries should be removed from string and individually charged. The voltage difference upon reassembly should be
no more than 0.2V.
BATTERIES SERIES CONNECTION GUIDE
General positive
General negative
SERIES CONNECTION GUIDELINES
CAUTION:

Severe damage to the battery, short circuiting and sparking will happen if the batteries are not connected correctly or properly
maintained. We recommend assembly be completed by fully trained professionals only.

Do not reverse connect the anode and cathode, as this will damage the batteries and/or any equipment connected.

DO not connect the batteries in parallel AND series at the same time.
Before install

Ensure wires can withstand twice the capacity rating of the battery. (Ex: ELBT6-LFP has a capacity of 6Ah, so the wire must be able
to withstand 12A.)

Charge all single batteries with 14.6V per standard charge and series batteries at a voltage of 14.6 times the number of batteries
in series.

Ensure all batteries have the same voltage level by fully charging each battery prior to connecting in series. (Voltage difference
<0.2V)
Install

Make sure the connections are tight and the connector is protected from corrosion, wear, and seismic situations. Connecting
impedance <0.1mΩ

DO NOT connect more than 4 batteries per circuit for the ELBT Series line
Maintenance

Make sure capacity stays within 50-60% when storing the batteries. The temperature should be 0-35 °C, humidity 75-85% and
fully charged every 3 months and discharged to 50-60% capacity.

Once a year, the batteries should be removed from string and individually charged. The voltage difference upon reassembly
should be no more than 0.2V..
Copyright © 2022 ELB. All rights reserved.
https://www.ecolithiumbattery.com/
Website: https://www.ecolithiumbattery.com/
Tel: (86)755-45963729
Mobile: +86 17746563763
Email: Info@ecolithiumbattery.com
Address: Lianhua industrial Zone, Huasheng Road, Dalang street, Longhua District, Shenzhen, China
Copyright © 2022 ELB. All rights reserved.