Small transformers
Small disconnector transformers TVTR
In these devices the primary coil is separated from the secondary coil by a basic insulator. They can be used for power transmission, control,
signalling actuating or other low voltage electric circuits, e.g. to generate functional low voltage (FELV) according to the standard
HD 60364-4-41 or to perform electrical protection to a secondary consumer with simple insulation.
The transformers deliver one-phase power with eight different secondary voltage values (Usec=3-6-12-18-24-42-110-230 V).
The transformers are built in conformity to the requirements within EN 60742 and EN 61558. Their degree of protection is IP00, i. e. they are
meant to be built in as parts into another equipment. Connections are ensured by screwed connectors with IP 20 degree of protection. Rated
powers range between 50 – 630 VA, depending on construction. The secondary coil has more wiretapping exits. The rated power refers to the
highest secondary voltage value. At the other wire-tapping exits the transformer delivers proportionally lower power values (see table).
Technical data
Nominal primary voltage (Upr):
Nominal secondary voltage (Usec):
Nominal frequency:
Rated power:
Protection class:
Degree of protection:
- at the connections:
Relative humidity limit:
Ambient temperature:
Heat-proof category:
230 V
3-6-12-18-24-42-110-230 V
(see table)
50/60 Hz
50 – 630 VA
I.
IP 00
IP 20
95 %
-5 °C – +40 °C
E (+120 °C)
RELEVANT STANDARD
RELEVANT STANDARD
EN 60742
EN 61558
Type selection
Tracon code
TVTR-50-A
TVTR-50-B
TVTR-50-C
TVTR-50-D
TVTR-50-F
TVTR-100-A
TVTR-100-B
TVTR-100-C
TVTR-100-D
TVTR-100-F
TVTR-150-B
TVTR-150-C
TVTR-150-D
TVTR-150-E
TVTR-150-F
TVTR-200-B
TVTR-200-C
TVTR-200-D
TVTR-200-E
TVTR-200-F
Rated power
50 VA
100 VA
150 VA
200 VA
Primary voltage
Upr
230 V
230 V
230 V
230 V
230 V
230 V
230 V
230 V
230 V
230 V
230 V
230 V
230 V
230 V
230 V
230 V
230 V
230 V
230 V
230 V
Secondary voltage
values Usec
3-6-12-18-24 V
6-12-18-24 V
12-24-42 V
24-42-110 V
24-230 V
3-6-12-18-24 V
6-12-18-24 V
12-24-42 V
24-42-110 V
24-230 V
6-12-18-24 V
12-24-42 V
24-42-110 V
42-110-230 V
24-230 V
6-12-18-24 V
12-24-42 V
24-42-110 V
42-110-230 V
24-230 V
Secondary power
values *
6,25-12,5-25-37,5-50 VA
12,5-25-37,5-50 VA
14,2-28,5-50 VA
10-19-50 VA
5,2-50 VA
12,5-25-50-75-100 VA
25-50-75-100 VA
28,5-57,1-100 VA
21,8-38,1-100 VA
10,4-100 VA
37,5-75-112,5-150 VA
42,8-85,7-150 VA
32,7-57,2-150 VA
27,3-71,7-150 VA
15,6-150 VA
50-100-150-200 VA
57,1-114,2-200 VA
43,6-76,3-200 VA
36,5-95,6-200 VA
20,8-200 VA
Max. secondary
current
2,08 A
2,08 A
1,19 A
0,45 A
0,21 A
4,16 A
4,16 A
2,38 A
0,90 A
0,43 A
6,25 A
3,57 A
1,36 A
0,65 A
0,65 A
8,30 A
4,76 A
1,81 A
0,86 A
0,86 A
* depending on the secondary voltage at the tapping exit;
H/54
Tracon Budapest Ltd. • Pallag Street 23, Dunakeszi, H-2120, Hungary
Tel.: +36-27-540-000, Fax: +36-27-540-005 • Website: www.traconelectric.com • E-mail: tracon@tracon.hu
Small transformers
Tracon code
TVTR-250-B
TVTR-250-C
TVTR-250-D
TVTR-250-E
TVTR-250-F
TVTR-300-B
TVTR-300-C
TVTR-300-D
TVTR-300-E
TVTR-300-F
TVTR-400-B
TVTR-400-C
TVTR-400-D
TVTR-400-E
TVTR-400-F
TVTR-500-C
TVTR-500-D
TVTR-500-E
TVTR-500-F
TVTR-630-C
TVTR-630-D
TVTR-630-E
TVTR-630-F
Rated power
250 VA
300 VA
400 VA
500 VA
630 VA
Primary voltage
Upr
230 V
230 V
230 V
230 V
230 V
230 V
230 V
230 V
230 V
230 V
230 V
230 V
230 V
230 V
230 V
230 V
230 V
230 V
230 V
230 V
230 V
230 V
230 V
Secondary voltage
values Usec
6-12-18-24 V
12-24-42 V
24-42-110 V
42-110-230 V
24-230 V
6-12-18-24 V
12-24-42 V
24-42-110 V
42-110-230 V
24-230 V
6-12-18-24 V
12-24-42 V
24-42-110 V
42-110-230 V
24-230 V
12-24-42 V
24-42-110 V
42-110-230 V
24-230 V
12-24-42 V
24-42-110 V
42-110-230 V
24-230 V
Secondary power
values *
62,5-125-187,5-250 VA
71,4-142,8-250 VA
54,5-95,4-250 VA
45,6-119,5-250 VA
26-250 VA
75-150-225-300 VA
85,7-171,4-300 VA
65,4-114,5-300 VA
54,7-143,4-300 VA
31,3-300 VA
100-200-300-400 VA
114,2-228,5-400 VA
87,2-152,7-400 VA
73-191,3-400 VA
41,7-400 VA
142,8-285,7-500 VA
109-190,9-500 VA
91,3-239,1-500 VA
52,1-500 VA
180-360-630 VA
137,4-240,5-630 VA
115-301,3-630 VA
65,7-630 VA
Max. secondary
current
10,41 A
5,95 A
2,27 A
1,08 A
1,08 A
12,50 A
7,14 A
2,72 A
1,30 A
1,30 A
16,66 A
9,52 A
3,63 A
1,73 A
1,73 A
11,90 A
4,54 A
2,17 A
2,17 A
15 A
5,72 A
5,73 A
2,73 A
* depending on the secondary voltage at the tapping exit;
Dimensions
Dimensions (mm)
Type
TVTR-50
TVTR-100
TVTR-150
TVTR-200
TVTR-250
TVTR-300
TVTR-400
TVTR-500
TVTR-630
B
76
87
102
102
102
120
120
147
147
D
80
94
88
95
102
106
110
138
145
Distance between fixation holes (mm)
E
77
87
100
100
96
110
110
135
135
A
56
64
83
83
75
90
90
115
115
C
50
60
70
76
85
84
88
122
125
Dimensions of
holes (mm)
J
K
7
5
8
6
8
6
8
6
11
8
11
8
11
8
11
8
11
8
Tracon Budapest Ltd. • Pallag Street 23, Dunakeszi, H-2120, Hungary
Tel.: +36-27-540-000, Fax: +36-27-540-005 • Website: www.traconelectric.com • E-mail: tracon@tracon.hu
Weight
(kg)
1,9
2,7
3,8
4,8
6,5
6,9
7,7
9,6
12,6
H/55
Small transformers
One-phase insulating transformers TVTRB
These products are meant for insulating separation in low-voltage power transmission, actuating, signalling, control and other circuits, to
generate shock-proof low voltage (SELV) according to the standard MSZ HD 60364-4-41. A protective separation is built in between the
primary and secondary coil. The safety insulating transformers deliver at the secondary side so-called safety low voltage below 50 V. The
insulating transformers deliver at the secondary side low voltage above 50 V.
All our transformers satisfy the requirements set within EN 60742 and EN 61558. Their degree of protection is IP00, i. e. they are meant to
be built in as parts into another equipment. Connections are ensured by screwed connectors with IP 20 degree of protection. Rated powers
range between 60 – 600 VA, depending on construction. The secondary coil has more wire-tapping exits.
The rated power refers to the highest secondary voltage value. At the other wire-tapping exits the transformer delivers proportionally lower
power values (see table).
Technical data
Nominal primary voltage (Upr):
Nominal secondary voltage (Usec):
Nominal frequency:
Rated power:
Protection class:
Degree of protection:
- at the connections:
Relative humidity limit:
Ambient temperature:
Heat-proof category:
400, 230 V
6, 12, 24, 42, 230 V
(see table)
50/60 Hz
60 … 600 VA
I.
IP 00
IP 20
95 %
-5 °C – +40 °C
E (+120 °C)
RELEVANT STANDARD
EN 60742
RELEVANT STANDARD
EN 61558
Type selection
Tracon code
TVTRB-60-A
TVTRB-60-D
TVTRB-60-F
TVTRB-60-M
TVTRB-60-O
TVTRB-60-P
TVTRB-100-A
TVTRB-100-D
TVTRB-100-F
TVTRB-100-M
TVTRB-100-O
TVTRB-100-P
Rated power
60 VA
100 VA
Primary voltage
Upr
230-400 V
230-400 V
230-400 V
230 V
230 V
230 V
230-400 V
230-400 V
230-400 V
230 V
230 V
230 V
Secondary voltage
values Usec
6-12-24 V
24-42 V
24-230 V
12 V
42 V
230 V
6-12-24 V
24-42 V
24-230 V
12 V
42 V
230 V
Secondary power
values *
15-30-60 VA
34,3-60 VA
6,2-60 VA
60 VA
60 VA
60 VA
25-50-100 VA
57,1-100 VA
10,4-100 VA
100 VA
100 VA
100 VA
Max. secondary
current
2,5 A
1,43 A
0,26 A
5A
1,43 A
0,26 A
4,17 A
2,38 A
0,43 A
8,33 A
2,38 A
0,43 A
* depending on the secondary voltage at the tapping exit;
H/56
Tracon Budapest Ltd. • Pallag Street 23, Dunakeszi, H-2120, Hungary
Tel.: +36-27-540-000, Fax: +36-27-540-005 • Website: www.traconelectric.com • E-mail: tracon@tracon.hu
Small transformers
Tracon code
TVTRB-160-B
TVTRB-160-D
TVTRB-160-F
TVTRB-160-M
TVTRB-160-O
TVTRB-160-P
TVTRB-250-B
TVTRB-250-D
TVTRB-250-F
TVTRB-250-O
TVTRB-250-P
TVTRB-400-B
TVTRB-400-D
TVTRB-400-F
TVTRB-400-O
TVTRB-400-R
TVTRB-600-B
TVTRB-600-D
TVTRB-600-O
TVTRB-600-P
TVTRB-600-R
Rated power
160 VA
250 VA
400 VA
600 VA
Primary voltage
Upr
230-400 V
230-400 V
230-400 V
230 V
230 V
230 V
230-400 V
230-400 V
230-400 V
230 V
230 V
230-400 V
230-400 V
230-400 V
230 V
400 V
230-400 V
230-400 V
230 V
230 V
400 V
Secondary voltage
values Usec
6-12-24 V
24-42 V
24-230 V
12 V
42 V
230 V
6-12-24 V
24-42 V
24-230 V
42 V
230 V
6-12-24 V
24-42 V
24-230 V
42 V
24 V
6-12-24 V
24-42 V
42 V
230 V
24 V
Secondary power
values *
40-80-160 VA
91,4-160 VA
16,7-160 VA
160 VA
160 VA
160 VA
62,5-125-250 VA
142,9-250 VA
26-250 VA
250 VA
250 VA
100-200-400 VA
228,6-400 VA
41,74 VA
400 VA
400 VA
150-300-600 VA
342,9-600 VA
600 VA
600 VA
600 VA
Max. secondary
current
6,67 A
3,81 A
0,70 A
13,34 A
3,81 A
0,70 A
10,42 A
5,95 A
1,09 A
5,95 A
1,09 A
16,67 A
9,52 A
1,74 A
9,52 A
16,67 A
25 A
14,29 A
14,29 A
2,61 A
25 A
* depending on the secondary voltage at the tapping exit;
Dimensions
Type
TVTRB-60
TVTRB-100
TVTRB-160
TVTRB-250
TVTRB-400
TVTRB-600
Dimensions [mm]
A
B
78
56
84
75
96
80
120 (130)** 88 (105)
120 (135) 118 (105)
135 (150) 125 (107)
C
93
98
108
108 (139)
129 (144)
144 (159)
Distance between
fixation holes [mm]
D
E
44
56
61
64
70
84
70 (72)
90 (104)
102 (86)
90 (104)
106 (83) 104 (122)
Dimensions of holes [mm]
F
9
9
11
11
11
11
G
4,8
4,8
5,8
5,8
5,8
5,8
H
20
24
35
35
35
35 (44)
I
3,6
3,6
3,6
3,6
3,6
3,6
Weight
(kg)
1,2
1,9
2,4
3,7
6,2
8
** Values between parentheses refer to the versions with –R or –S as the last character of the code.
SCAN THE QR CODE!
Check our new products
Be updated
Our assortment is expanding quickly and
continuously! This catalogue reflects the status in
November 2013.
Be up to date by our web page!
Tracon Budapest Ltd. • Pallag Street 23, Dunakeszi, H-2120, Hungary
Tel.: +36-27-540-000, Fax: +36-27-540-005 • Website: www.traconelectric.com • E-mail: tracon@tracon.hu
H/57
Download