mcBSC training for BSC TS (BSC up and running) Antti Palojärvi For internal use Unique document identifier (ID) / Version number / Life cycle status 1 © Nokia Siemens Networks 2012 Dept. / Author / Date mcBSC up and running • In this document it is briefly described all the steps what are needed to get 2 module mcBSC up and running. • Referred documents • • • • • • • • • Multicontroller Site IP Connectivity Guidelines DN0982823 BSC Site IP Configuration Principles DN0982835 Commissioning a standalone mcBSC Commissioning mcBSC and mcTC DN0982859 Creating and Managing mcBSC Hardware DN0982847 BSS Integration DN9812243 Multicontroller BSC and Multicontroller TC Installation Quick Guide DN05209732 All the steps are not necessarily needed in case SW is already been preinstalled in factory. Also all the printouts are straight from working environment located in Tampere TS lab. For internal use Unique document identifier (ID) / Version number / Life cycle status 2 © Nokia Siemens Networks 2012 Dept. / Author / Date BCN/BOC-A esw manual upgrade For internal use Unique document identifier (ID) / Version number / Life cycle status 3 © Nokia Siemens Networks 2012 Dept. / Author / Date BCN/BOC-A esw manual upgrade 1/6 • • Currently with the latest MP’s esw upgrade to BCN and BOC-A units is possible to do via MML command class ZWD. Check the current esw of BCN and BOC-A units. root@BCNMB-A:~# sw_fw_versioninfo Active U-Boot Version 3.1.1 (in flash 0) This part of the printout tells the current esw SW of BCN Backup U-Boot Version 3.1.1 (in flash 1) LMP Version 3.1.1 PCB Version A103-2/A103-3/A103-4/A103-5/A103-6/A103-7 LED CPLD Version 05 PCI-LPC bridge XP2 Version 03 VCMC Version 3.1.1 PWR1014 Version 0007 FRUD Version 3.1.1 Part Number C111721.A1A ... ... This part of the printout tells the current esw SW of BOC-A in cpu slot 4 Add-in Card 4 MMC Version 3.1.1 Part Number C111723.A1A BCNOC-A PCPL Version 0.3.0 BCNOC-A OCTF Version 3.1.1 BCNOC-A FRUD Version 3.1.1 For internal use Unique document identifier (ID) / Version number / Life cycle status 4 © Nokia Siemens Networks 2012 Dept. / Author / Date BCN/BOC-A esw manual upgrade 2/6 • • If manual upgrade is needed like in case very old box is taken into use upgrade can be done from USB memory stick. Proven working steps for upgrading esw is 1.4->1.8.->2.0->2.4->2.7.1->3.1.1. 1. Before the upgrade save following data from BCN. • • • Swtich configurations (main/ext) • With WinSCP or straight from terminal LMP IP configuration root@BCNMB-A:~# root@BCNMB-A:~# root@BCNMB-A:~# root@BCNMB-A:~# cat /etc/sysconfig/network-scripts/ifcfg-eth0 cat /etc/sysconfig/network cat /etc/sysconfig/network-scripts/ifcfg-eth0.800 ifconfig -a root@BCNMB-A:~# root@BCNMB-A:~# root@BCNMB-A:~# root@BCNMB-A:~# mch_cli mch_cli mch_cli mch_cli HW management info For internal use Unique document identifier (ID) / Version number / Life cycle status 5 © Nokia Siemens Networks 2012 Dept. / Author / Date GetNodeNumber GetRackNumber GetFRUPCIeRC GetPCIeRC BCN/BOC-A esw manual upgrade 3/6 • Message Bus & boot script configuration root@BCNMB-A:~# mch_cli FRU info 0x20 root@BCNMB-A:~# cat /etc/ipmi/mch.conf • Current SW info root@BCNMB-A:~# sw_fw_versioninfo 2. For the BCN & BOC-A upgrade prepare usb memory stick that has the correct esw. (from isource/sharenet) • Following files need to be present autorun.scr autorun.scr.md5 ncp20000.dtb ncp20000.dtb.md5 ncp20000-initrd-upgrade-3.1.1.gz.uboot ncp20000-initrd-upgrade-3.1.1.gz.uboot.md5 setip.sh setip.sh.md5 uImage uImage.md5 For internal use Unique document identifier (ID) / Version number / Life cycle status 6 © Nokia Siemens Networks 2012 Dept. / Author / Date BCN/BOC-A esw manual upgrade 4/6 3. Check that LMP has valid date settings root@BCNMB-A:~# date Tue Sep 25 11:13:05 UTC 2012 If not okay give valid date root@BCNMB-A:~# date –set=”25 sep 2012 11:14:00” 4. Disable OMU in M1 to prevent DX diagnostic for the units during the upgrade root@BCNMB-A:~# 5. mch_cli Deactivate cpu8 Plug the USB stick into BCN and give power restart. • At first SW will be copied into LMP. • After succesfull copy actual upgrade process will start. • If upgare does not start automatically script can be started manually (check the date before this). root@BCNMB-A:~# /opt/upgrade/upgrade.sh • From the menu select ”Fully automatic upgrade” For internal use Unique document identifier (ID) / Version number / Life cycle status 7 © Nokia Siemens Networks 2012 Dept. / Author / Date BCN/BOC-A esw manual upgrade 5/6 6. Upgrade procedure can be followed from log files Progress root@BCNMB-A:~# cat /tmp/autoupgrade.log Result root@BCNMB-A:~# cat /opt/upgrade/autorun.log 7. Once upgrade is complete remove the USB stick and give power restart 8. After BCN has restarted to the new SW check the SW config root@BCNMB-A:~# sw_fw_versioninfo Active U-Boot Version 3.1.1 (in flash 0) Backup U-Boot Version 3.1.1 (in flash 1) LMP Version 3.1.1 PCB Version A103-2/A103-3/A103-4/A103-5/A103-6/A103-7 LED CPLD Version 05 PCI-LPC bridge XP2 Version 03 VCMC Version 3.1.1 PWR1014 Version 0007 FRUD Version 3.1.1 Part Number C111721.A1A … 9. Enable OMU root@BCNMB-A:~# mch_cli Activate cpu8 For internal use Unique document identifier (ID) / Version number / Life cycle status 8 © Nokia Siemens Networks 2012 Dept. / Author / Date BCN/BOC-A esw manual upgrade 6/6 10. Modify the mnt/fastpath2/module/post.soc with vi editor root@BCNMB-A:~# cat /mnt/fastpath2/module/post.soc echo "/mnt/fastpath2/module/post.soc" linkscan interval=10000 #trunk add id=0 pbmp=0x3000000 !Trunk add line has to be commented For internal use Unique document identifier (ID) / Version number / Life cycle status 9 © Nokia Siemens Networks 2012 Dept. / Author / Date BJC-A esw manual upgrade For internal use Unique document identifier (ID) / Version number / Life cycle status 10 © Nokia Siemens Networks 2012 Dept. / Author / Date BJC-A esw manual upgrade • • • Currently with the latest MP’s esw(GA) upgrade to BJC-A units is possible to do via MML command class ZWD. If manual upgrade is needed like in case very old box is taken into use upgrade can be done from USB memory stick. GA SW need to be updated step by step • For detailed instructions refer attached document For internal use Unique document identifier (ID) / Version number / Life cycle status 11 © Nokia Siemens Networks 2012 Dept. / Author / Date BJC-A BIOS settings For internal use Unique document identifier (ID) / Version number / Life cycle status 12 © Nokia Siemens Networks 2012 Dept. / Author / Date BJC-A BIOS settings 1. Connect to the BIOS in each BJC-A module and configure the BIOS as instructed in the Commissioning mcBSC and mcTC document. • BIOS of the BJC-A unit can be accessed only from restart prompt of the unit. • Correct steps: 1. Restart the unit with mch_cli (deactivate -> activate) 2. Immediately open connection to the same unit (minicom) 3. Wait for the ” Press <ESC> or <F2> to enter setup” 4. Immediately press ESC and BIOS terminal should open. • TIP! •. BIOS terminal alignment is really confusing with minicom access from LMP. •. Better way is to use direct port access via IP mgmt interface For internal use Unique document identifier (ID) / Version number / Life cycle status 13 © Nokia Siemens Networks 2012 Dept. / Author / Date Switch config restore For internal use Unique document identifier (ID) / Version number / Life cycle status 14 © Nokia Siemens Networks 2012 Dept. / Author / Date Switch config restore 1/2 • • If text based configuration file with binary header is available upload the file into correct /mnt/fastpath folder with WinSCP (main: fastpath, ext:fastpath2) Then apply the new script in correct switch. (Stated in training doc1) (Broadcom FASTPATH Switching) > (Broadcom FASTPATH Switching) >ena Password: (Broadcom FASTPATH Switching) #clear config Are you sure you want to clear the configuration? (y/n)y Clearing configuration. Please wait for login prompt. (Unit 1)>m20 SFP+1 (phy21) DOWN, set secondary via SFP+2 (phy22) m20 SFP+2 (phy22) DOWN, set secondary via SFP+1 (phy21) User:admin Password: (Broadcom FASTPATH Switching) > (Broadcom FASTPATH Switching) #script apply Husabox2main_190912.scr Are you sure you want to apply the configuration script? (y/n)y Configuration script 'Husabox2main_190912.scr' applied. (HusaBox2MainSwitch) # (HusaBox2MainSwitch) #write mem This operation may take a few minutes. Management interfaces will not be available during this time. Are you sure you want to save? (y/n) y Config file 'startup-config' created successfully . Configuration Saved! (HusaBox2MainSwitch) # For internal use Unique document identifier (ID) / Version number / Life cycle status 15 © Nokia Siemens Networks 2012 Dept. / Author / Date Switch config restore 2/2 • • Configuration can be also written (copy paste) directly into switch terminal. Default configuration scripts for M1 and M2 attached. • These can be applied with copy paste direclty into switch prompt in priviledge mode. • Application VLAN’s and external interfaces are not defined as well the prompt name. SA_main1.txt • SA_main2.txt SA_Ext_1& 2 Detailed description of switch related files can be found from MultiController Site IP Connectivity Guidelines & BSC Site IP Configuration Principles. For internal use Unique document identifier (ID) / Version number / Life cycle status 16 © Nokia Siemens Networks 2012 Dept. / Author / Date FRU data configuration For internal use Unique document identifier (ID) / Version number / Life cycle status 17 © Nokia Siemens Networks 2012 Dept. / Author / Date FRU data configuration 1/5 Rack & Node number 1. Check Rack & Node number definition in FRU BOX 1 (M1) root@BCNMB-A:~# 65 root@BCNMB-A:~# 1 root@BCNMB-A:~# BOX 2 (M2) root@BCNMB-A:~# 65 root@BCNMB-A:~# 1 root@BCNMB-A:~# mch_cli GetRackNumber mch_cli GetNodeNumber mch_cli GetRackNumber mch_cli GetNodeNumber Rack number is the ascii coordinate of Rack. (eg. A=65, F = 70) Node number is the module number in mcBSC. Example OMU box M1 cartridge in rack A is created with 1A1-0 2. Modify rack & node number if needed BOX 1 (M1) root@BCNMB-A:~# mch_cli SetRackNumber 65 root@BCNMB-A:~# mch_cli SetNodeNumber 1 BOX 2 (M2) root@BCNMB-A:~# mch_cli SetRackNumber 65 root@BCNMB-A:~# mch_cli SetNodeNumber 2 For internal use Unique document identifier (ID) / Version number / Life cycle status 18 © Nokia Siemens Networks 2012 Dept. / Author / Date FRU data configuration 2/5 Root complex 3. Check root complex configuration BOX 1 (M1) root@BCNMB-A:~# Slot8 root@BCNMB-A:~# RC: 8 root@BCNMB-A:~# BOX 2 (M2) root@BCNMB-A:~# LMP root@BCNMB-A:~# RC: 0 root@BCNMB-A:~# mch_cli GetFRUPCIeRC mch_cli GetPCIeRC mch_cli GetFRUPCIeRC mch_cli GetPCIeRC Unit in M1 slot 8 (OMU) has root complex. In other modules it is configured to LMP. 4. Modify root complex if needed BOX 1 (M1) root@BCNMB-A:~# mch_cli SetFRUPCIeRC slot8 root@BCNMB-A:~# mch_cli SetPCIeRC 8 BOX 2 to 8 (M2-M8) root@BCNMB-A:~# mch_cli SetFRUPCIeRC LMP root@BCNMB-A:~# mch_cli SetPCIeRC 0 Unit in M1 slot 8 (OMU) has root complex. In other modules it is configured to LMP. For internal use Unique document identifier (ID) / Version number / Life cycle status 19 © Nokia Siemens Networks 2012 Dept. / Author / Date FRU data configuration 3/5 MB address 5. Check MB address definitions of BJC-A units M1 root@BCNMB-A:~# mch_cli FRU info 0x20 [NSN.EMB Addresses] Vendor Format Version = 0 Slot 1 = 0x0004 //MCMU 0 Slot 2 = 0x0049 //BCXU 0 Slot 3 = 0x004A //BCXU 1 Slot 4 = 0xFFFF Slot 5 = 0xFFFF Slot 6 = 0xFFFF Slot 7 = 0xFFFF Slot 8 = 0x0000 //OMU M2 root@BCNMB-A:~# mch_cli FRU info 0x20 [NSN.EMB Addresses] Vendor Format Version = 0 Slot 1 = 0x0005 //MCMU 1 Slot 2 = 0x004B //BCXU 2 Slot 3 = 0x004C //BCXU 3 Slot 4 = 0xFFFF Slot 5 = 0xFFFF Slot 6 = 0xFFFF Slot 7 = 0xFFFF Slot 8 = 0xFFFF For internal use Unique document identifier (ID) / Version number / Life cycle status 20 © Nokia Siemens Networks 2012 Dept. / Author / Date FRU data configuration 4/5 MB address 6. Define MB addresses of CPU units in Box1 (M1) if needed MCMU-0 in slot 1: ipmitool -I lan -H 127.0.0.1 -U admin -P admin raw 0x2e 0x20 0x2a 0x6f 0x00 0x2a 0x6f 0x00 0x07 0x00 0x01 0x02 0x00 0x04 BCXU-0 in slot 2: ipmitool -I lan -H 127.0.0.1 -U admin -P admin raw 0x2e 0x20 0x2a 0x6f 0x00 0x2a 0x6f 0x00 0x07 0x00 0x03 0x02 0x00 0x49 BCXU-1 in slot 3: ipmitool -I lan -H 127.0.0.1 -U admin -P admin raw 0x2e 0x20 0x2a 0x6f 0x00 0x2a 0x6f 0x00 0x07 0x00 0x05 0x02 0x00 0x4A OMU in slot 8: ipmitool -I lan -H 127.0.0.1 -U admin -P admin raw 0x2e 0x20 0x2a 0x6f 0x00 0x2a 0x6f 0x00 0x07 0x00 0x0f 0x02 0x00 0x00 Refresh IPMI FRU: mch_cli FRU refresh 0x20 Check MB addresses with mch_cli: mch_cli FRU info 0x20 For internal use Unique document identifier (ID) / Version number / Life cycle status 21 © Nokia Siemens Networks 2012 Dept. / Author / Date FRU data configuration 5/5 MB address 7. Define MB addresses of CPU units in Box2 (M2) if needed MCMU-1 in slot 1: ipmitool -I lan -H 127.0.0.1 -U admin -P admin raw 0x2e 0x20 0x2a 0x6f 0x00 0x2a 0x6f 0x00 0x07 0x00 0x01 0x02 0x00 0x05 BCXU-2 in slot 2: ipmitool -I lan -H 127.0.0.1 -U admin -P admin raw 0x2e 0x20 0x2a 0x6f 0x00 0x2a 0x6f 0x00 0x07 0x00 0x03 0x02 0x00 0x4B BCXU-3 in slot 3: ipmitool -I lan -H 127.0.0.1 -U admin -P admin raw 0x2e 0x20 0x2a 0x6f 0x00 0x2a 0x6f 0x00 0x07 0x00 0x05 0x02 0x00 0x4C Refresh IPMI FRU: mch_cli FRU refresh 0x20 Check MB addresses with mch_cli: mch_cli FRU info 0x20 For internal use Unique document identifier (ID) / Version number / Life cycle status 22 © Nokia Siemens Networks 2012 Dept. / Author / Date Boot script & boot order For internal use Unique document identifier (ID) / Version number / Life cycle status 23 © Nokia Siemens Networks 2012 Dept. / Author / Date Boot script & Boot order 1/2 • PIU’s bootscript and correct boot sequence are defined in /etc/ipmi/mch.conf file • Use vi editor to configure the file in each module • Correct boot sequence in M1 module is 8 1 2 3 4 5 6 7 which meas that OMU will be restarted first. For the other modules sequence is 1 2 3 4 5 6 7 8. • Correct bootscript for the BOC-A units is 17 and for the BJC-A units 99. • Also check that the first octect in each card config for BOC-A units is root@BCNMB-A:~# vi /etc/ipmi/mch.conf 0x18, notBasic 0x08.vi commands: a Esc :wq! :q! i Enter to edit mode (Add new text) Enter from edit mode to command mode Save changes and exit from vi Exit from vi without saving changes Insert text before cursor, until <Esc> hit For internal use Unique document identifier (ID) / Version number / Life cycle status 24 © Nokia Siemens Networks 2012 Dept. / Author / Date Boot script & Boot order 2/2 • Example of /etc/ipmi/mch.conf file root@BCNMB-A:~# cat /etc/ipmi/mch.conf ###################### # Global Configuration ###################### 1.bootscript=99 # delay between cards card_between_delay=5 5 5 5 5 5 5 5 # Data bytes # byte1: # [6] pci boot # [5] failsafe # [4] clock source # [3-0] mul # byte2: # [7] boot flash # [6] buffer dir # [5-0] reserverd # byte3: reserved # byte4: reserved # byte5-21: reserved 1.card_conf=0x08 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x00 0x0 0 0x00 0x00 0x00 0x00 0x00 0x00 0x00 # boot sequence boot_order=8 1 2 3 4 5 6 7 ###################### # CPU Add-in Card #1 ###################### # Boot Script # 0: Rerserved and do nothgin # 1-32: NSN # 33: DEMI burn-in # 34: hw ddr2 # 35: traf_gen_freeze # 36: U-Boot recover # 37: U-Boot bootloader_flash_update # 38: Linux linux_flash_update # 61-68: Manufacture burn-in program # 70: Run Linux # 80: Net boot defined by NSN For internal use Unique document identifier (ID) / Version number / Life cycle status 25 © Nokia Siemens Networks 2012 Dept. / Author / Date # enable 1.enable=1 LMP IP configuration For internal use Unique document identifier (ID) / Version number / Life cycle status 26 © Nokia Siemens Networks 2012 Dept. / Author / Date LMP IP configuration • • Configure IP related files with vi editor. BCN Management interface (used for LMP terminal connection) 1. 2. • /etc/sysconfig/network-scripts/ifcfg-eth0 in M1 DEVICE=eth0 BOOTPROTO=static BROADCAST=10.41.81.31 IPADDR=10.41.81.15 NETMASK=255.255.255.224 ONBOOT=yes /etc/sysconfig/network in M1 NETWORKING=yes HOSTNAME=ncp20000 FORWARD_IPV4=false GATEWAY="10.41.81.1" NOZEROCONF=yes This is management port configuration. In this example own subnet used for management connections LMP vlan 800 interface (mcBSC platform internal management) 1. /etc/sysconfig/network-scripts/ifcfg-eth0.800 in M1 DEVICE=eth0.800 VLAN=yes BOOTPROTO=dhcp ONBOOT=yes PERSISTENT_DHCLIENT=Y DHCLIENTARGS="-nw" For internal use Unique document identifier (ID) / Version number / Life cycle status 27 This is management port configuration. In this example own subnet used for management connections © Nokia Siemens Networks 2012 Dept. / Author / Date This is IMPI vlan configuration. LMP uses dhcp to get adress from OMU. LMP IP configuration • • Configure IP related files with vi editor. BCN Management interface (used for LMP terminal connection) 1. 2. • /etc/sysconfig/network-scripts/ifcfg-eth0 in M2 DEVICE=eth0 BOOTPROTO=static BROADCAST=10.41.81.31 IPADDR=10.41.81.16 NETMASK=255.255.255.224 ONBOOT=yes /etc/sysconfig/network in M2 NETWORKING=yes HOSTNAME=ncp20000 FORWARD_IPV4=false GATEWAY="10.41.81.1" NOZEROCONF=yes This is management port configuration. In this example own subnet used for management connections LMP vlan 800 interface (mcBSC platform internal management) 1. /etc/sysconfig/network-scripts/ifcfg-eth0.800 in M2 DEVICE=eth0.800 VLAN=yes BOOTPROTO=dhcp ONBOOT=yes PERSISTENT_DHCLIENT=Y DHCLIENTARGS="-nw" For internal use Unique document identifier (ID) / Version number / Life cycle status 28 This is management port configuration. In this example own subnet used for management connections © Nokia Siemens Networks 2012 Dept. / Author / Date This is IMPI vlan configuration. LMP uses dhcp to get adress from OMU. LMP IP configuration 4. Restart the interfaces & check the configuration. (in both modules) root@BCNMB-A:~# ifdown eth0 root@BCNMB-A:~# ifup eth0 root@BCNMB-A:~# ifdown eth0.800 Removed VLAN -:eth0.800:root@BCNMB-A:~# ifup eth0.800 Added VLAN with VID == 800 to IF -:eth0:Determining IP information for eth0.800... done. root@BCNMB-A:~# root@BCNMB-A:~# ifconfig ... eth0 Link encap:Ethernet HWaddr 00:D0:C9:BB:AE:1D inet addr:10.41.81.16 Bcast:10.41.81.31 Mask:255.255.255.224 inet6 addr: fe80::2d0:c9ff:febb:ae1d/64 Scope:Link UP BROADCAST RUNNING MULTICAST MTU:1500 Metric:1 RX packets:1205075 errors:0 dropped:0 overruns:0 frame:0 TX packets:1189921 errors:0 dropped:0 overruns:0 carrier:0 collisions:0 txqueuelen:1000 RX bytes:101678521 (96.9 MiB) TX bytes:154711208 (147.5 MiB) Base address:0xe000 eth0.800 Link encap:Ethernet HWaddr 00:D0:C9:BB:AE:1D inet addr:10.10.10.11 Bcast:10.10.10.255 Mask:255.255.255.0 inet6 addr: fe80::2d0:c9ff:febb:ae1d/64 Scope:Link UP BROADCAST RUNNING MULTICAST MTU:1500 Metric:1 RX packets:18 errors:0 dropped:0 overruns:0 frame:0 TX packets:23 errors:0 dropped:0 overruns:0 carrier:0 collisions:0 txqueuelen:0 RX bytes:1430 (1.3 KiB) TX bytes:1846 (1.8 KiB) For internal use Unique document identifier (ID) / Version number / Life cycle status 29 © Nokia Siemens Networks 2012 Dept. / Author / Date If LMP does not get IP adress from OMU OMU is not yet in WO state Rack & Node configurations are not in order ifcg-eth0.800 file not in order - Vlan 800 config in main switches are not in order. LMP boot script installation For internal use Unique document identifier (ID) / Version number / Life cycle status 30 © Nokia Siemens Networks 2012 Dept. / Author / Date LMP Boot script installation • LMP Boot script controls the adding card restarts during LMP restart. 1. Download LMP boot script from isource. isource link Currently in use revision 2881 dated 30.9.2011 2. Copy script files to LMP with WinSCP. "resetNodes.sh" to directory /etc/rc.d/init.d/ "nodeReset.sh" to directory /usr/bin/ 3. Change the modules executable if needed root@BCNMB-A:~# cd /usr/bin root@BCNMB-A:/usr/bin# chmod +x+x+x nodeReset.sh root@BCNMB-A:/usr/bin# cd /etc/rc.d/init.d/ root@BCNMB-A:/etc/rc.d/init.d# chmod +x+x+x resetNodes.sh root@BCNMB-A:/etc/rc.d/init.d# cd root@BCNMB-A:~# For internal use Unique document identifier (ID) / Version number / Life cycle status 31 © Nokia Siemens Networks 2012 Dept. / Author / Date LMP Boot script installation 1. Add service “resetNodes.sh” into the configuration. root@BCNMB-A:~# cd /etc/rc.d/init.d/ root@BCNMB-A:/etc/rc.d/init.d# chkconfig --add resetNodes.sh root@BCNMB-A:/etc/rc.d/init.d# cd root@BCNMB-A:~# 2. Check that resetNodes is added properly root@BCNMB-A:~# cracklibd crond dhcpd dhcrelay netconsole netfs network ntpd rdisc resetNodes.sh sshd syslog watchdog xinetd chkconfig --list 0:off 1:off 2:on 0:off 1:off 2:on 0:off 1:off 2:off 0:off 1:off 2:off 0:off 1:off 2:off 0:off 1:off 2:off 0:off 1:off 2:on 0:off 1:off 2:off 0:off 1:off 2:off 0:off 1:off 2:off 0:off 1:off 2:on 0:off 1:off 2:on 0:off 1:off 2:off 0:off 1:off 2:off For internal use Unique document identifier (ID) / Version number / Life cycle status 32 © Nokia Siemens Networks 2012 Dept. / Author / Date 3:on 3:on 3:off 3:off 3:off 3:on 3:on 3:on 3:off 3:on 3:on 3:on 3:on 3:on 4:on 4:on 4:off 4:off 4:off 4:on 4:on 4:off 4:off 4:off 4:on 4:on 4:off 4:on 5:on 5:on 5:off 5:off 5:off 5:on 5:on 5:off 5:off 5:off 5:on 5:on 5:off 5:on 6:off 6:off 6:off 6:off 6:off 6:off 6:off 6:off 6:off 6:off 6:off 6:off 6:off 6:off Cabling For internal use Unique document identifier (ID) / Version number / Life cycle status 33 © Nokia Siemens Networks 2012 Dept. / Author / Date Cabling • • Verify that interconnection cables are connected as defined in Multicontroller BSC and Multicontroller TC Installation Quick Guide. If cables from extension switches of M1 and M2 are already connected to site equipment it is good idea to shut down the interface at site equipment side until all the configurations are done. For internal use Unique document identifier (ID) / Version number / Life cycle status 34 © Nokia Siemens Networks 2012 Dept. / Author / Date HigGig script For internal use Unique document identifier (ID) / Version number / Life cycle status 35 © Nokia Siemens Networks 2012 Dept. / Author / Date HiGig script 1/3 Check • Check current HiGig configuration Used script and xmesh version root@BCNMB-A:~# cat /opt/cluster/m10/init.soc echo echo init mesh6 ver 0.3.9, module 10 0:port 0x1fffffff en=f 0:local module 10 0:mod port 0 29 my_modid=@module 0:mod modport_map 0x0 7424 higig_port_bitmap=0x00000000 0:mod src_modid_block 0x1500 256 port_block_mask_bitmap=0x1fffffff 0:mod src_modid_block 0x1600 256 port_block_mask_bitmap=0x1fffffff 0:mod src_modid_block 0x1700 256 port_block_mask_bitmap=0x1fffffff 0:mod src_modid_block 0x1800 256 port_block_mask_bitmap=0x1fffffff 0:mod src_modid_block 0x0100 256 port_block_mask_bitmap=0x1fffffff root@BCNMB-A:~# Module specific fastapath link(m10 for module 1, m20 for module2…) root@BCNMB-A:~# ls -la /mnt/fastpath/module lrwxrwxrwx 1 root root 16 Aug 29 14:13 /mnt/fastpath/module -> /opt/cluster/m10 root@BCNMB-A:~# post.soc file root@BCNMB-A:~# cat /opt/cluster/m10/post.soc | grep "0x001fffe4" #0:port 0x001fffe4 enc=ieee sp=10000 an=off en=t root@BCNMB-A:~# Line “0:port 0x001fffe4 enc=ieee sp=10000 an=off en=t” has to commented with # For internal use Unique document identifier (ID) / Version number / Life cycle status 36 © Nokia Siemens Networks 2012 Dept. / Author / Date HiGig script 2/3 Installation • Install HiGig if needed 1. Copy HiGig file into /opt folder with WinSCP example: nsn.23a91279e4d4f4f6206e0d470633cbdc2462d7a1.backplane-0.3.9-1.tar.gz 2. Unzip the HiGig file in LMP root@BCNMB-A:/opt# tar -xzf nsn.23a91279e4d4f4f6206e0d470633cbdc2462d7a1.backplane-0.3.9-1.tar.gz root@BCNMB-A:/opt# 3. Copy HiGig files into correct locations 4. root@BCNMB-A:/opt# cp backplane-0.3.9/mesh backplane-0.3.9/xmesh /usr/bin root@BCNMB-A:/opt# cp backplane-0.3.9/xmeshd /etc/init.d Copy mesh6.xml into folder with WinSCP root@BCNMB-A:/opt# cp /opt backplane-0.3.9/*.xml . • • mesh6.xml used in upto 6 BCN environments pmesh8.xml used in 7 & 8 BCN environments and xmeshd has to be added into startup list. For internal use Unique document identifier (ID) / Version number / Life cycle status 37 © Nokia Siemens Networks 2012 Dept. / Author / Date HiGig script 3/3 Installation 5. Check that following line is commented away in mesh6.xml root@BCNMB-A:/opt# #0:port 0x001fffe4 #0:port 0x001fffe4 #0:port 0x001fffe4 #0:port 0x001fffe4 #0:port 0x001fffe4 #0:port 0x001fffe4 root@BCNMB-A:/opt# cat mesh6.xml | grep "0:port 0x001fffe4 enc=ieee sp=10000 an=off en=t" enc=ieee sp=10000 an=off en=t enc=ieee sp=10000 an=off en=t enc=ieee sp=10000 an=off en=t enc=ieee sp=10000 an=off en=t enc=ieee sp=10000 an=off en=t enc=ieee sp=10000 an=off en=t # in every line 6. Install HigGig Run mesh by using proper box specific attributes root@BCNMB-A:/opt# mesh -x mesh6.xml -m 10 Box1 m=10, box2 m=20, box3 m=30... 7. Take HiGig into use !High Cabling and switch configuration has to be on order before this step Reboot BCN root@BCNMB-A:/opt# reboot Or root@BCNMB-A:/opt# touch var/run/cluster/ext/post.soc For internal use Unique document identifier (ID) / Version number / Life cycle status 38 © Nokia Siemens Networks 2012 Dept. / Author / Date BSC package For internal use Unique document identifier (ID) / Version number / Life cycle status 39 © Nokia Siemens Networks 2012 Dept. / Author / Date BSC package • • • Current version of BCN OMU does not have visibility to USB port in front panel. Therefore the convenient way to copy the BSC package to WDU is to do the copying in FlexiBSC from U0 to W0 as in this example. !Note After P8 factory delivered mcBSC’s have SW in the WDU. For internal use Unique document identifier (ID) / Version number / Life cycle status 40 © Nokia Siemens Networks 2012 Dept. / Author / Date BSC package • Steps 1. Install the disk into Flexi BSC. 2. Format the disk. ZMID:W0-<DISK_NAME>.DIR,FF,2,<INITIALS> 3. Create the directories. ZMCD:W0-/ASF_2_18_0,50 ZMCD:W0-/SCMANA,FF ZMCD:W0-/ANSI,FF ZMCD:W0-/ETSI,FF ZMCD:W0-/ASF_2_18_0/BLCODE,900 ZMCD:W0-/ASF_2_18_0/MMDIRE,900 ZMCD:W0-/ASF_2_18_0/LFILES,900 ZMCD:W0-/ASF_2_18_0/CDTEMP,FF ZMCD:W0-/ASF_2_18_0/ASWDIR,FF ZMCD:W0-/ASF_2_18_0/CONVPR,FF ZMCD:W0-/ASF_2_18_0/LICENCE,200 ZMCD:W0-/ASF_2_18_0/WEBFIL,FF ZMCD:W0-/ASF_2_18_0/WEBFIL/APPS,FF ZMCD:W0-/ASF_2_18_0/WEBFIL/CGI,FF ZMCD:W0-/ASF_2_18_0/WEBFIL/HTDOCS,FF ZMCD:W0-/ASF_2_18_0/WEBFIL/SCRIPT,FF ZMCD:W0-/ASF_2_18_0/WEBFIL/ICONS,FF ZMCD:W0-/ASF_2_18_0/WEBFIL/GRAPHICS,FF For internal use Unique document identifier (ID) / Version number / Life cycle status 41 © Nokia Siemens Networks 2012 Dept. / Author / Date BSC package 3. Attach USB stick that has complete package into OMU of FlexiBSC • • 4. In this example USB root contains valid BOLEROGX.IMG Also /ETSI & /ANSI folders contain PRFILE and FIFILE Copy the files from USB to W0 ZMMS:U0-/SCMANA/*.*,W0-/SCMANA/ ZMMS:U0-/*.*,W0-/ ZMMS:U0-/ETSI/*.*,W0-/ETSI/ ZMMS:U0-/ANSI/*.*,W0-/ANSI/ ZMMS:U0-/ASF_2_18_0/LFILES/*.*,W0-/ASF_2_18_0/LFILES/ ZMMS:U0-/ASF_2_18_0/BLCODE/*.*,W0-/ASF_2_18_0/BLCODE/ ZMMS:U0-/ASF_2_18_0/MMDIRE/*.*,W0-/ASF_2_18_0/MMDIRE/ ZMMS:U0-/ASF_2_18_0/ASWDIR/*.*,W0-/ASF_2_18_0/ASWDIR/ ZMMS:U0-/ASF_2_18_0/WEBFIL/*.*,W0-/ASF_2_18_0/WEBFIL/ ZMMS:U0-/ASF_2_18_0/WEBFIL/CGI/*.*,W0-/ASF_2_18_0/WEBFIL/CGI/ ZMMS:U0-/ASF_2_18_0/WEBFIL/HTDOCS/*.*,W0-/ASF_2_18_0/WEBFIL/HTDOCS/ ZMMS:U0-/ASF_2_18_0/WEBFIL/SCRIPT/*.*,W0-/ASF_2_18_0/WEBFIL/SCRIPT/ ZMMS:U0-/ASF_2_18_0/WEBFIL/ICONS/*.*,W0-/ASF_2_18_0/WEBFIL/ICONS/ ZMMS:U0-/ASF_2_18_0/WEBFIL/GRAPHICS/*.*,W0-/ASF_2_18_0/WEBFIL/GRAPHICS/ For internal use Unique document identifier (ID) / Version number / Life cycle status 42 © Nokia Siemens Networks 2012 Dept. / Author / Date BSC package 5. Remove the WDU from FlexiBSC and attach it to M1 6. Restart the cpu8 and log into OMU minidebugger by pressing ‘m’ during reboot in OMU’s minicom session. root@BCNMB-A:~# mch_cli Deactivate cpu8 Set fru activation policy: clear deactivation lock bit! deactivate: Command completed normally root@BCNMB-A:~# mch_cli Activate cpu8 Clear locked bit! done: Command completed normally Set FRU Activation! done: Command completed normally root@BCNMB-A:~#minicom cpu8 7. In minidebugger check that OMU sees the WDU and content in W0 ZMX:W0-/ • 8. If OMU does not see the W0 run the recovery script described in exercise doc and go back to step 6. In minidebugger format W1 ZMID:W1-<DISK_NAME>.DIR,FF,2,<INITIALS> For internal use Unique document identifier (ID) / Version number / Life cycle status 43 © Nokia Siemens Networks 2012 Dept. / Author / Date BSC package 9. In minidebugger copy the PRFILE and FIFLE to LFILES ZMM:W0-/xxxx/*.*,W0-/ASF_2_18_0/LFILES/ Xxxx = ANSI or ETSI 10. If needed patch the NE number to APPARA ZMVL:W1-/ASF_2_18_0/BLCODE/APPARAGX.IMG,4,B0 ZMVL:W1-/ASF_2_18_0/BLCODE/APPARAG2.IMG,4,B0 You can move to the correct location in the file (block B0) with the arrow keys. At block B0, the pre-entered value is: 00B0: 45 23 01 If the delivery’s NE number is, for example, 102345, it must be written as following into the files: 00B0: 45 23 10 Exit the editing mode by pressing <CTRL> <C>, after which the program prompts you to confirm the modifications made. WRITE TO DISK Y/N? Y Confirm the changes by answering Y <ENTER> 11. In minidebugger copy the whole content of W0 to W1 ZMMD:W0-/*.*:*,W1-/ For internal use Unique document identifier (ID) / Version number / Life cycle status 44 © Nokia Siemens Networks 2012 Dept. / Author / Date BSC package 12. Restart the OMU with “ZAUL” 13. If OMU does not find the disks try recovery scripts stated at the end of exercices material. 14. If OMU does not start to the correct package start the minidebugger with “m” during the restart phase and patch the SOMAFI. •. •. •. !TIP. In practice it is currently possible to copy the SW to mcBSC WDU so that USB memory is attached directly to the USB port in OMU’s BJCA-A unit. Once OMU is started into minidebugger OMU sees the USB port as U0. This is not recommended since it required that BCN cover is opened while BCN is powered up. Also USB interface will be removed from BJCA-A’s later on. For internal use Unique document identifier (ID) / Version number / Life cycle status 45 © Nokia Siemens Networks 2012 Dept. / Author / Date mcBSC creation For internal use Unique document identifier (ID) / Version number / Life cycle status 46 © Nokia Siemens Networks 2012 Dept. / Author / Date mcBSC creation. • • Please refere to the Creating and Managing mcBSC Hardware document. In following steps mcKOFF is being created by following IP plan McBSC KOFF10.255.164.0/24 VLAN name VLAN nbr BITS in MASK MASK GATEWAY 1 GATEWAY 2 GW2 switch GATEWAY 3 GW3 switch BROADCAST Koff O&M 3910 29255.255.255.248 10.9.192.232 10.9.192.233 10.9.192.234 techsup1 10.9.192.235 techsup2 10.9.192.239 BTS vlan 3900 28255.255.255.248 10.255.164.176 10.255.164.177 10.255.164.178 techsup1 10.255.164.179 techsup2 10.255.164.191 sigtran-1 3932 28255.255.255.240 10.255.164.160 10.255.164.161 10.255.164.162 techsup1 10.255.164.163 techsup2 10.255.164.175 sigrtan-2 3933 28255.255.255.240 10.255.164.144 10.255.164.145 10.255.164.146 techsup1 10.255.164.147 techsup2 10.255.164.159 Synch 3934 29255.255.255.248 10.255.164.192 10.255.164.193 10.255.164.194 techsup1 10.255.164.195 techsup2 10.255.164.199 etpsig-e 3943 28255.255.255.240 10.255.164.128 10.255.164.129 10.255.164.130 techsup1 10.255.164.131 techsup2 10.255.164.143 omu- trxsig 3944 28255.255.255.240 10.255.164.112 10.255.164.113 10.255.164.114 techsup1 10.255.164.115 techsup2 10.255.164.127 aoip 3946 28255.255.255.240 10.255.164.96 10.255.164.97 10.255.164.98 techsup1 10.255.164.99 techsup2 10.255.164.111 ater 3947 28255.255.255.240 10.255.164.80 10.255.164.81 10.255.164.82 techsup1 10.255.164.83 techsup2 10.255.164.95 pabis 3948 28255.255.255.240 10.255.164.64 10.255.165.65 10.255.164.66 techsup1 10.255.164.67 techsup2 10.255.164.79 gb 3949 26255.255.255.192 10.255.164.0 10.255.164.1 10.255.164.2 techsup1 10.255.164.3 techsup2 10.255.164.63 For internal use Unique document identifier (ID) / Version number / Life cycle status 47 NETWORK © Nokia Siemens Networks 2012 Dept. / Author / Date mcBSC creation. HW creation 1. Load VIMLA and configure OMU IP for better connection. ZLP:1,VIM; Z1CT:1; ZQRA:OMU::EL0:; ZQRA:OMU::EL1:; ZQRA:OMU::VLAN3910,3910,EL1,,::; ZQRN:OMU::VLAN3910,:"10.9.192.236",29,; ZQKM:OMU::"10.9.192.236":"10.9.192.233":; ZIAA:PROFILE::::FTP=W:;“ ZQNM:0:NAME=mcKOFF,LOC=BSCTECHSUPTRE; Now IP connection is possible if site equipment, main switch & extension switch configuration is on order 2. Change the topology. ZW6G:SAT1:; For internal use Unique document identifier (ID) / Version number / Life cycle status 48 © Nokia Siemens Networks 2012 Dept. / Author / Date mcBSC creation. HW creation 3. Create rack BCN’s and BJA-A cards ZWTJ:GCBV,1A,; ZWTC:BCNC,1A001-0,,:; ZWTC:BCNC,1A002-0,,:; Box 1 ZWTU:MCBC,0:1A1-0; ZWTP:MCBC,0:BCN_A,0,1,1; ZWTU:MCMU,0:1A001-0:MB=4,UTY=MCBC,UIN=0:; ZWTP:MCMU,0:BJC_A,0,1,1; ZWTU:BCXU,0:1A001-0:MB=49,UTY=MCBC,UIN=0:; ZWTP:BCXU,0:BJC_A,0,1,2; ZWTU:BCXU,1:1A001-0:MB=4A,UTY=MCBC,UIN=0:; ZWTP:BCXU,1:BJC_A,0,1,3; ZWTU:OMU:1A001-0:MB=0,UTY=MCBC,UIN=0:; ZWTP:OMU:BJC_A,0,1,8; For internal use Unique document identifier (ID) / Version number / Life cycle status 49 © Nokia Siemens Networks 2012 Dept. / Author / Date Box 2 ZWTU:MCBC,1:1A2-0; ZWTP:MCBC,1:BCN_A,0,1,1; ZWTU:MCMU,1:1A002-0:MB=5,UTY=MCBC,UIN=1:; ZWTP:MCMU,1:BJC_A,0,1,1; ZWTU:BCXU,2:1A002-0:MB=4B,UTY=MCBC,UIN=1:; ZWTP:BCXU,2:BJC_A,0,1,2; ZWTU:BCXU,3:1A002-0:MB=4C,UTY=MCBC,UIN=1:; ZWTP:BCXU,3:BJC_A,0,1,3; mcBSC creation. HW creation 4. Create and Configure EMB, PEM, FAN, WDU, & PTUM for both modules ZWTU:EMB,0; ZWTU:EMB,1; ZWTU:PEM,0:1A1-0:UTY=MCBC,UIN=0; ZWTP:PEM,0:BPSU_A,0,1,1; ZWTU:PEM,1:1A1-0:UTY=MCBC,UIN=0; ZWTP:PEM,1:BPSU_A,0,1,2; ZWTU:PEM,2:1A2-0:UTY=MCBC,UIN=1; ZWTP:PEM,2:BPSU_A,0,1,1; ZWTU:PEM,3:1A2-0:UTY=MCBC,UIN=1; ZWTP:PEM,3:BPSU_A,0,1,2; ZWTU:FAN,0:1A1-0:UTY=MCBC,UIN=0; ZWTP:FAN,0:BFAN_A,0,1,1; ZWTU:FAN,1:1A1-0:UTY=MCBC,UIN=0; ZWTP:FAN,1:BFAN_A,0,1,2; ZWTU:FAN,2:1A1-0:UTY=MCBC,UIN=0; ZWTP:FAN,2:BFAN_A,0,1,3; ZWTU:FAN,3:1A2-0:UTY=MCBC,UIN=1; ZWTP:FAN,3:BFAN_A,0,1,1; ZWTU:FAN,4:1A2-0:UTY=MCBC,UIN=1; ZWTP:FAN,4:BFAN_A,0,1,2; ZWTU:FAN,5:1A2-0:UTY=MCBC,UIN=1; ZWTP:FAN,5:BFAN_A,0,1,3; For internal use Unique document identifier (ID) / Version number / Life cycle status 50 © Nokia Siemens Networks 2012 Dept. / Author / Date ZWTU:WDU,0:1A001-0:MAS=OMU:; ZWTP:WDU,0:HDSAM_A,0,1,1; ZWTU:WDU,1:1A002-0:MAS=OMU:; ZWTP:WDU,1:HDSAM_A,0,1,1; ! Create PTUM only if equipped. ZWTU:PTUM,0:1A001-0:UTY=MCBC,UIN=0:; ZWTP:PTUM,0:BSAC_A,0,1,2; ZWTU:PTUM,1:1A002-0:UTY=MCBC,UIN=1:; ZWTP:PTUM,1:BSAC_A,0,1,2; mcBSC creation. HW creation 5. Restart the system at this point ZUSS:SYM; 6. After OMU is restarted activate the modules. Box1 ZUSC:MCBC,0:SE; ZUSC:MCBC,0:TE; ZUSC:MCBC,0:WO; Follow from service terminal that MCMU0, BCXU0 & BCXU 1 are restarting properly. Box2 ZUSC:MCBC,1:SE; ZUSC:MCBC,1:TE; ZUSC:MCBC,1:WO; Follow from service terminal that MCMU1, BCXU2 & BCXU 3 are restarting properly. For internal use Unique document identifier (ID) / Version number / Life cycle status 51 © Nokia Siemens Networks 2012 Dept. / Author / Date mcBSC creation. HW creation 7. Create BOC-A units in both modules Box 1 ZWTU:PCUM,0:1A001-0:UTY=MCBC,UIN=0:; ZWTP:PCUM,0:BOC_A,0,1,4; ZWTU:PCUM,1:1A001-0:UTY=MCBC,UIN=0:; ZWTP:PCUM,1:BOC_A,0,1,5; ZWTU:ETME,0:1A001-0:UTY=MCBC,UIN=0:; ZWTP:ETME,0:BOC_A,0,1,6; ZWTU:ETMA,0:1A001-0:UTY=MCBC,UIN=0:; ZWTP:ETMA,0:BOC_A,0,1,7; Box 2 ZWTU:PCUM,2:1A002-0:UTY=MCBC,UIN=1:; ZWTP:PCUM,2:BOC_A,0,1,4; ZWTU:PCUM,3:1A002-0:UTY=MCBC,UIN=1:; ZWTP:PCUM,3:BOC_A,0,1,5; ZWTU:PCUM,4:1A002-0:UTY=MCBC,UIN=1:; ZWTP:PCUM,4:BOC_A,0,1,6; ZWTU:ETME,1:1A002-0:UTY=MCBC,UIN=1:; ZWTP:ETME,1:BOC_A,0,1,7; ZWTU:ETMA,1:1A002-0:UTY=MCBC,UIN=1:; ZWTP:ETMA,1:BOC_A,0,1,8; For internal use Unique document identifier (ID) / Version number / Life cycle status 52 © Nokia Siemens Networks 2012 Dept. / Author / Date mcBSC creation. VLAN800 8. Configure management VLAN800 & LDI • VLAN 800 is used for internal management purposes inside of Multicontroller platform e.g. DHCP for LMP and PTUM, IPMI and SNMP VLAN800 ZQRA:OMU::VLAN800,800,EL0,,::; ZQRA:MCMU,0::EL0:; ZQRA:MCMU,0::EL1:; ZQRA:MCMU,1::EL0:; ZQRA:MCMU,1::EL1:; ZQRA:MCMU,0::VLAN800,800,EL0,,::; ZQRA:MCMU,1::VLAN800,800,EL0,,::; ZQRN:MCMU::VLAN800:"10.10.10.2",24,L,I,; LDI ZWYB:800:CNW,800,LDI:; ZWYC:800:MCBC,0:MCMU,0,VLAN800:; ZWYC:800:MCBC,1:MCMU,0,VLAN800:; ZW6E:MCBC,0:A:; ZW6E:MCBC,1:A:; ZW6E:MCBC,100:A:; //Ei tarvita ?? ZW6E:MCBC,101:A:; //Ei tarvita ?? ZUSC:CNW,800:SE; ZUSC:CNW,800:TE; ZUSC:CNW,800:WO; ZQRN:MCMU,0::EL0,:"10.200.200.2",24,L,I:; ZQRN:MCMU,0::EL1,:"10.200.201.2",24,L,i:; For internal use Unique document identifier (ID) / Version number / Life cycle status 53 © Nokia Siemens Networks 2012 Dept. / Author / Date mcBSC creation. Unit interfaces 9. Create IP interfaces for the units ZQRA:PCUM,0::IFETH0; ZQRA:PCUM,0::IFETH1; ZQRA:PCUM,1::IFETH0; ZQRA:PCUM,1::IFETH1; ZQRA:PCUM,2::IFETH0; ZQRA:PCUM,2::IFETH1; ZQRA:PCUM,3::IFETH0; ZQRA:PCUM,3::IFETH1; ZQRA:PCUM,4::IFETH0; ZQRA:PCUM,4::IFETH1; ZQRA:ETME,0::IFETH0; ZQRA:ETME,0::IFETH1; ZQRA:ETME,1::IFETH0; ZQRA:ETME,1::IFETH1; ZQRA:ETMA,0::IFETH0; ZQRA:ETMA,0::IFETH1; ZQRA:ETMA,1::IFETH0; ZQRA:ETMA,1::IFETH1; ZQRA:BCXU,0::EL0; ZQRA:BCXU,0::EL1; ZQRA:BCXU,1::EL0; ZQRA:BCXU,1::EL1; ZQRA:BCXU,2::EL0; ZQRA:BCXU,2::EL1; ZQRA:BCXU,3::EL0; ZQRA:BCXU,3::EL1; For internal use Unique document identifier (ID) / Version number / Life cycle status 54 © Nokia Siemens Networks 2012 Dept. / Author / Date mcBSC creation. VLAN20 10. Create VLAN20 • Signalling VLAN 20 is used for management and control traffic (ETPSIG and PCUSIG), DHCP and software downloading purposes for BOC-A cards as ETMA, ETME and PCUM. ZQRA:MCMU,0::VLAN20,20,EL0,:::; ZQRA:MCMU,1::VLAN20,20,EL0,:::; ZQRN:MCMU,0::VLAN20,:"10.0.1.3",25,L,IM; ZQRA:BCXU,0::VLAN20,20,EL0,,::; ZQRA:BCXU,1::VLAN20,20,EL0,,::; ZQRA:BCXU,2::VLAN20,20,EL0,,::; ZQRA:BCXU,3::VLAN20,20,EL0,,::; ZQRN:BCXU,0::VLAN20:"10.0.1.10",25,L,IMC; ZQRN:BCXU,1::VLAN20:"10.0.1.11",25,L,IMC; ZQRN:PCUM,0::IFETH0:"10.0.1.20",25,P,DIM:; ZQRN:PCUM,1::IFETH0:"10.0.1.21",25,P,DIM:; ZQRN:PCUM,2::IFETH0:"10.0.1.22",25,P,DIM:; ZQRN:PCUM,3::IFETH0:"10.0.1.23",25,P,DIM:; ZQRN:PCUM,4::IFETH0:"10.0.1.24",25,P,DIM:; ZQRN:ETMA,0::IFETH0:"10.0.1.30",25,P,DIM:; ZQRN:ETMA,1::IFETH0:"10.0.1.31",25,P,DIM:; ZQRN:ETME,0::IFETH0:"10.0.1.33",25,P,DIM:; ZQRN:ETME,1::IFETH0:"10.0.1.34",25,P,DIM:; ZQRN:ETMA,0::IFETH0:"10.0.1.40",25,P,CI:; ZQRN:ETMA,1::IFETH0:"10.0.1.41",25,P,CI:; ZQRN:ETME,0::IFETH0:"10.0.1.43",25,L,CI:; !IP address only for working MCMU / BCXU’s For internal use Unique document identifier (ID) / Version number / Life cycle status 55 © Nokia Siemens Networks 2012 Dept. / Author / Date mcBSC creation. VLAN23 11. Create VLAN23 • EEP VLAN 23 is used for transporting CS traffic between ETMA and ETME cards. ZQRA:ETME,0::VLAN23,23,IFETH0,::UP:; ZQRA:ETME,1::VLAN23,23,IFETH0,::UP:; ZQRN:ETME,0::VLAN23:"10.0.3.1",25,L,I:; ZQRP:ETME,0::VLAN23:"10.0.3.1":TAG,"EEP":; ZQRA:ETMA,0::VLAN23,23,IFETH0,::UP:; ZQRA:ETMA,1::VLAN23,23,IFETH0,::UP:; ZQRN:ETMA,0::VLAN23:"10.0.3.10",25,P,I:; ZQRP:ETMA,0::VLAN23:"10.0.3.10":TAG,"EEP":; ZQRN:ETMA,1::VLAN23:"10.0.3.11",25,P,I:; ZQRP:ETMA,1::VLAN23:"10.0.3.11":TAG,"EEP":; • ! Once you start to create BTS’s remember to create route from ETMA to BTS via ETME EEP For internal use Unique document identifier (ID) / Version number / Life cycle status 56 © Nokia Siemens Networks 2012 Dept. / Author / Date mcBSC creation. VLAN24 12. Create VLAN24 • PEP VLAN 24 is used for transport PS traffic between PCUM and ETME cards. ZQRA:ETME,0::VLAN24,24,IFETH0,::UP:; ZQRA:ETME,1::VLAN24,24,IFETH0,::UP:; ZQRN:ETME,0::VLAN24:"10.0.3.129",25,L,I:; ZQRP:ETME,0::VLAN24:"10.0.3.129":TAG,"PEP":; ZQRA:PCUM,0::VLAN24,24,IFETH0,::UP:; ZQRA:PCUM,1::VLAN24,24,IFETH0,::UP:; ZQRA:PCUM,2::VLAN24,24,IFETH0,::UP:; ZQRA:PCUM,3::VLAN24,24,IFETH0,::UP:; ZQRA:PCUM,4::VLAN24,24,IFETH0,::UP:; ZQRN:PCUM,0::VLAN24:"10.0.3.140",25,L,I:; ZQRN:PCUM,1::VLAN24:"10.0.3.141",25,L,I:; ZQRP:PCUM,0::VLAN24:"10.0.3.140":TAG,"PEP":; ZQRP:PCUM,1::VLAN24:"10.0.3.141":TAG,"PEP":; For internal use Unique document identifier (ID) / Version number / Life cycle status 57 © Nokia Siemens Networks 2012 Dept. / Author / Date mcBSC creation. VLAN32 13. Create VLAN32 • Sigtran-1 VLAN 32 is used for transport SCTP based traffic and used by different applications: A-Sigtran, BBI and Lb. ZQRA:MCMU,0::VLAN3932,3932,EL1,::UP:; ZQRA:MCMU,1::VLAN3932,3932,EL1,::UP:; ZQRA:BCXU,0::VLAN3932,3932,EL1,::UP:; ZQRA:BCXU,1::VLAN3932,3932,EL1,::UP:; ZQRA:BCXU,2::VLAN3932,3932,EL1,::UP:; ZQRA:BCXU,3::VLAN3932,3932,EL1,::UP:; ZQRN:MCMU,0::VLAN3932,:"10.255.164.164",28,L,::; ZQRN:BCXU,0::VLAN3932,:"10.255.164.165",28,L,::; ZQRN:BCXU,1::VLAN3932,:"10.255.164.166",28,L,::; ZQKM:MCMU,0::"10.255.164.164":"10.255.164.161":LOG:; ZQKM:BCXU,0::"10.255.164.165":"10.255.164.161":LOG:; ZQKM:BCXU,1::"10.255.164.166":"10.255.164.161":LOG:; For internal use Unique document identifier (ID) / Version number / Life cycle status 58 © Nokia Siemens Networks 2012 Dept. / Author / Date mcBSC creation. VLAN44 & VLAN45 14. Create VLAN44 & VLAN45 • OMUSIG VLAN 44 and TRXSIG 45 are used for IP connectivity between BCXU and BTS using Packet Abis over Ethernet. ZQRA:BCXU,0::VLAN3944,3944,EL1,,::UP:; ZQRA:BCXU,1::VLAN3944,3944,EL1,,::UP:; ZQRA:BCXU,2::VLAN3944,3944,EL1,,::UP:; ZQRA:BCXU,3::VLAN3944,3944,EL1,,::UP:; ZQRN:BCXU,0::VLAN3944:"10.255.164.116",28,L,::; ZQRN:BCXU,1::VLAN3944:"10.255.164.117",28,L,::; ZQKM:BCXU,0::"10.255.164.116":"10.255.164.113":LOG:; ZQKM:BCXU,1::"10.255.164.117":"10.255.164.113":LOG:; For internal use Unique document identifier (ID) / Version number / Life cycle status 59 © Nokia Siemens Networks 2012 Dept. / Author / Date mcBSC creation. VLAN46 15. Create VLAN46 • AoIP VLAN 46 is used for transport CS user plane traffic between ETMA and MGW in a case of transcoding in MGW. ZQRA:ETMA,0::VLAN3946,3946,IFETH1,,::UP:; ZQRA:ETMA,1::VLAN3946,3946,IFETH1,,::UP:; ZQRN:ETMA,0::VLAN3946:"10.255.164.100",28,P,::; ZQRN:ETMA,1::VLAN3946:"10.255.164.101",28,P,::; ZQKC:ETMA,0:::"10.255.164.97":PHY:; ZQKC:ETMA,1:::"10.255.164.97":PHY:; For internal use Unique document identifier (ID) / Version number / Life cycle status 60 © Nokia Siemens Networks 2012 Dept. / Author / Date mcBSC creation. VLAN48 16. Create VLAN48 • PAbis VLAN 48 is used for transport Packet Abis traffic between ETME and IP BTS using Packet Abis over Ethernet. ZQRA:ETME,0::VLAN3948,3948,IFETH1,,::UP:; ZQRA:ETME,1::VLAN3948,3948,IFETH1,,::UP:; ZQRN:ETME,0::VLAN3948:"10.255.164.68",28,L,::; ZQKC:ETME,0:::"10.255.164.65":LOG:; For internal use Unique document identifier (ID) / Version number / Life cycle status 61 © Nokia Siemens Networks 2012 Dept. / Author / Date mcBSC creation. VLAN49 17. Create VLAN49 • Gb VLAN 49 is used for interconnection for PCUMs in a case of PCU Pooling (PCP) feature and Gb interface between SGSN and PCUMs. ZQRA:PCUM,0::VLAN3949,3949,IFETH1,,::UP:; ZQRA:PCUM,1::VLAN3949,3949,IFETH1,,::UP:; ZQRA:PCUM,2::VLAN3949,3949,IFETH1,,::UP:; ZQRA:PCUM,3::VLAN3949,3949,IFETH1,,::UP:; ZQRA:PCUM,4::VLAN3949,3949,IFETH1,,::UP:; ZQRN:PCUM,0::VLAN3949:"10.255.164.4",26,L,::; ZQRN:PCUM,1::VLAN3949:"10.255.164.5",26,L,::; ZQKC:PCUM,0:::"10.255.164.1":LOG:; ZQKC:PCUM,1:::"10.255.164.1":LOG:; ZQRP:PCUM,0::VLAN3949:"10.255.164.4":TAG,"GB":; ZQRP:PCUM,0::VLAN3949:"10.255.164.4":TAG,"IPL":; ZQRP:PCUM,1::VLAN3949:"10.255.164.5":TAG,"GB":; ZQRP:PCUM,1::VLAN3949:"10.255.164.5":TAG,"IPL":; For internal use Unique document identifier (ID) / Version number / Life cycle status 62 © Nokia Siemens Networks 2012 Dept. / Author / Date mcBSC creation. IUA 18. Create IUA messaging configuration PCUSIG ZD2C:P:BCXU,0::PCUM,0; ZD2C:P:BCXU,1::PCUM,1; ZD2C:P:BCXU,0::PCUM,2; ZD2C:P:BCXU,1::PCUM,3; ZD2C:P:BCXU,0::PCUM,4; ETPSIG-M ZD2C:M:BCXU,0::ETME,0; ZD2C:M:BCXU,1::ETME,1; ZD2C:M:BCXU,1::ETMA,0; ZD2C:M:BCXU,0::ETMA,1; ETPSIG-C for ETME ZD2C:C,NOR:BCXU,0::ETME,0; ZD2C:C,NOR:BCXU,1::ETME,0; ETPSIG-C for ETMA ZD2C:C,NOR:BCXU,0::ETMA,0; ZD2C:C,NOR:BCXU,0::ETMA,1; ZD2C:C,NOR:BCXU,1::ETMA,0; ZD2C:C,NOR:BCXU,1::ETMA,1; For internal use Unique document identifier (ID) / Version number / Life cycle status 63 © Nokia Siemens Networks 2012 Dept. / Author / Date mcBSC creation. Host BCXU 19. Create host BCXU ZD3C:PCUM,0:BCXU,0:; ZD3C:PCUM,1:BCXU,1:; !IF PCUM is in SP state platform will raise the PCU to WO state once host is created. For internal use Unique document identifier (ID) / Version number / Life cycle status 64 © Nokia Siemens Networks 2012 Dept. / Author / Date mcBSC creation. Start up the BOC-A units 20. Start up the BOC-A units ZUSC:PCUM,0:SE; ZUSC:PCUM,1:SE; ZUSC:PCUM,2:SE; ZUSC:PCUM,3:SE; ZUSC:PCUM,4:SE; ZUSC:PCUM,0:TE; ZUSC:PCUM,1:TE; ZUSC:PCUM,2:TE; ZUSC:PCUM,3:TE; ZUSC:PCUM,4:TE; Follow that PCUM's are raising up to TE ZUSC:PCUM,0:SP; ZUSC:PCUM,1:SP; ZUSC:PCUM,2:SP; ZUSC:PCUM,3:SP; ZUSC:PCUM,4:SP; Follow that PCUM's are raising up to SP & WO For internal use Unique document identifier (ID) / Version number / Life cycle status 65 © Nokia Siemens Networks 2012 Dept. / Author / Date ZUSC:ETME,0:SE; ZUSC:ETME,1:SE; ZUSC:ETMA,0:SE; ZUSC:ETMA,1:SE; ZUSC:ETME,0:TE; ZUSC:ETME,1:TE; ZUSC:ETMA,0:TE; ZUSC:ETMA,1:TE; Follow that ETME & ETMA's are raising up to TE ZUSC:ETME,0:SP; ZUSC:ETME,1:SP; ZUSC:ETMA,0:WO; ZUSC:ETMA,1:WO; Follow that ETME & ETMA's are raising up to SP & WO mcBSC creation. Lincence & Features 21. Install and activate the licence and features For internal use Unique document identifier (ID) / Version number / Life cycle status 66 © Nokia Siemens Networks 2012 Dept. / Author / Date mcBSC creation. Sigtran 22. Create Sigtran interface ZOYC:LIISA:C:M3UA:; ZOYA:LIISA:BCXU,0:IETF:; ZOYM:LIISA:NETWORK=8:; ZOYP:M3UA:LIISA,0:"10.255.164.165",,:"10.8.192.5",24,,,:; ZNRP:NA0,116,KOFFI,STP:::; ZNSP:NA0,391,LIISA:0:LIISA:; ZNRC:NA0,391,LIISA,6,A,:,,,7:; ZNFD:NA0,116,0:; ZNFB:NA0,116:FE,BSSAP,0,; ZNPC:NA0,03,SCCP:Y:Y,208,10F:; ZNFD:NA0,391,0:FE,BSSAP,0,; ZNHC:NA0,116:FE:ACT; ZNVA:NA0,391::; ZNVC:NA0,391::ACT:; ZNGC:NA0,391:ACT:; ZNLA:0:; ZNLC:0,ACT:; ZNHC:NA0,391:FE:ACT:; ZOYS:M3UA:LIISA,0:ACT:; For internal use Unique document identifier (ID) / Version number / Life cycle status 67 © Nokia Siemens Networks 2012 Dept. / Author / Date mcBSC creation. BTS 23. Create BTS ZOYX:BTS1SCTPOM1:IUA:S:BCXU,0:AFAST:2:; ZOYP:IUA:BTS1SCTPOM1:"10.255.164.116",,49152:"10.255.164.180",29,,,49152:; ZOYX:BTS1SCTPT01:IUA:S:BCXU,0:AFAST:4:; ZOYP:IUA:BTS1SCTPT01:"10.255.164.116",,49153:"10.255.164.180",29,,,49153:; ZDWP:OM001:BCXU,0:62,1:BTS1SCTPOM1,0:; ZDWP:T0001:BCXU,0:0,1:BTS1SCTPT01,0:; ZOYV:IUA::A; ZDWQ; ZEWC:EX4IR2BL110:MF=BTSE4003,EXT=A0X,SDIR=PACK_1,; ZEWS:E:EX4IR2BL110:; ZEFC:4,E,:DNAME=OM001,:::::BCUIP=10.255.164.180,SMCUP=29,BMIP=10.255.164.180,SMMP=29,ETMEID=0,VLANID=3948,; ZOYS:IUA:BTS1SCTPOM1:ACT:; ZOYS:IUA:BTS1SCTPT01:ACT:; ZEQC:BCF=4,BTS=1,:CI=1401,BAND=1800:NCC=0,BCC=0:MCC=520,MNC=18,LAC=116::; ZEUC:BTS=1,; ZEUG:BTS=1:PMAX2=20; ZEHC:BTS=1,; ZERC:BTS=1,TRX=1::FREQ=665,TSC=0,:DNAME=T0001:CH0=MBCCHC,; • Route from ETMA to BTS via ETME EEP ZQKC:ETMA,0::"10.255.164.180",32:"10.0.3.1":PHY:; ZQKC:ETMA,1::"10.255.164.180",32:"10.0.3.1":PHY:; For internal use Unique document identifier (ID) / Version number / Life cycle status 68 © Nokia Siemens Networks 2012 Dept. / Author / Date mcBSC creation. NSEI 24. Create PEP links for active PCUM units ZESK:ETME,0::PCU,0:; ZESK:ETME,0::PCU,1:; 25. Create NSEI ZFXA:PSEI=0,PCU=0; ZFXK:NSEI=401,NSVLI=401,NAME=NETTA1,PSEI=0:LPNBR=50303,NRID=67,PRE=Y:RIP="10.8.37.37",RPNBR=49999,; ZEBF:MCC=520,MNC=18,LAC=116,RAC=1:NSEI=401:; For internal use Unique document identifier (ID) / Version number / Life cycle status 69 © Nokia Siemens Networks 2012 Dept. / Author / Date mcBSC creation. Synchronisation 26. Synchronisation Create sync cables between boxes(2 boxes): ZWTA:MCBC,0:BCN_A,0:SYNC,1:MCBC,1:BCN_A,0:SYNC,0:; ZWTA:MCBC,1:BCN_A,0:SYNC,1:MCBC,0:BCN_A,0:SYNC,0:; Create PTUM/BSAC card (if not created already in step 4) : PTUM-0, 1st box’s AMC2: ZWTU:PTUM,0:1A001-0:UTY=MCBC,UIN=0:; ZWTP:PTUM,0:BSAC_A,0,1,2; PTUM-1, last box’s AMC2: ZWTU:PTUM,1:1A003-0:UTY=MCBC,UIN=2:; ZWTP:PTUM,1:BSAC_A,0,1,2; ZUSC:PTUM,0:SE; ZUSC:PTUM,0:TE; ZUSC:PTUM,0:WO; ZUSC:PTUM,1:SE; ZUSC:PTUM,1:TE; ZUSC:PTUM,1:WO; For internal use Unique document identifier (ID) / Version number / Life cycle status 70 © Nokia Siemens Networks 2012 Dept. / Author / Date mcBSC creation. Synchronisation PCM synchronization: Connect PCM to first box Sync1. Set sync priority: ZDYM:MCBC,0:EXT,1:PRI=2,; Check sync status: ZDYI; - It is possible to use PTUM’s(BSAC card) PCM interface ToP synchronization with PTUM: Needs BSAC card 1. Create synchronization role: ZDYA:PTUM,0:I,C:LP=“<LOCAL IP>",RP=“<REMOTE IP>",MASK=<MASK>,GW=“<GATEWAY>":; 2. Set sync priority: ZDYM:PTUM,0:SFP,1:PRI=1,; 3. Check role: ZDYB; 4. Check sync status: ZDYI; Tips: If ZDYI fails * PTUM-0 has always IP 10.10.10.50 and PTUM-1 10.10.10.51. Try ping from LMP to BSAC card. If fails deactivate/activate amc2: mch_cli Deactivate AMC2 mch_cli Aactivate AMC2 Try ping again. - MML state change - It doesn’t cause resets for BSAC card. Program block includes BSAC card to ZDYI if state is WO-EX. •. Complete. Now there should working environment. For internal use Unique document identifier (ID) / Version number / Life cycle status 71 © Nokia Siemens Networks 2012 Dept. / Author / Date