Uploaded by Andrew Butler

Garrison Presentation 20220408 (002)

advertisement
®
POWERMAX
for Small to Medium
Scale Microgrids
Brandon Marcum
© 2023 SEL
POWERMAX
2002
Timeline
2008
2014
2018
2019
POWERMAX
POWERMAX
POWERMAX
POWERMAX
POWERMAX
Industrial
Utility
Commercial
Mobile
Garrison
Key POWERMAX Solution Differences
Segment
Mobile
Garrison
Commercial
Industrial
Utilities
Technology
TMS
TMS + Garrison
POWERMAX
POWERMAX
POWERMAX
RTAC
RTAC
RTAC
MW Range
Key Differences
0.01 – 1
Disaster reliefs, army bases, remote islanded facilities – mainly
for diesel generators (DGs) using distributed communication
architecture
0.1 – 10
Solution for small- to mid-sized microgrids using DG, solar
photovoltaic (PV), battery energy storage system (BESS) for
simple bus topology using distributed communication architecture
1 – 1,000
Solution for mid- to large-sized microgrids using any kind of
distributed energy resource (DER) (natural gas turbine / diesel /
steam / solar PV / BESS / wind / fuel cell) using centralized
communication architecture
10 – 5,000
Solution for mid- to large-sized industrial facilities using any kind
of DER (NG / DG / steam / solar PV / BESS / wind / fuel cell)
using centralized communication architecture
Solution for wide-area protection to maintain grid-wise stability
using distributed and centralized architecture; remedial action
Transmission level
schemes (RASs)
Development History of
POWERMAX Mobile
Tactical Microgrid Standard
Taking The Military’s Standards to the Industry
TQG
AMMPS
TMS
Quiet
1980
Efficient
2005
Interoperable
2018
Demonstration for US Army Corps of Engineers
100 kW CAT
60 kW TQG
30 kW Taylor
30 kW Gillette
Loads
Loads
Loads
Loads
Loads
Loads
POWERMAX® Mobile Trailer
30 kW Taylor
60 kW TQG
80 kW/30kVAR
Stepped Loadbank
30 kW Gillette
How it Works
Advanced Control Techniques
SUPERIOR TO PID METHODS
Engine Manufacturer
PID Controls
Frequency
(Hz)
Power
(W)
SEL
State Space Controls
60
No overshoot
58
No integral windup
56
No oscillations
30,000
No tuning
15,000
Fully interoperable
0
Data Distribution Service (DDS) Brings Plug-andPlay Communications
Hi! I’m a generator.
Great! Send me data.
Only available
from SEL
Engineering
Services
Technology Allows Interoperability
WITH ANY SIZE GENSET
100 kW
5 kW
+
+
What it means for you
Distributed Relay Control Solution
REDUCES COMPLEXITY AND COST
Is equivalent to $40,000 of
competitor equipment
Uses same interface for all
inverters and gensets
Simplifies the user experience
Ensures interoperability between
DER manufacturers
Distributed Relay Control Solution
INCLUDES INNOVATIVE FEATURES
Advanced controls
and visualization
Superior protection
and diagnostics
Plug-and-play
TMS MC dispatch
Minimal Retraining
IDENTICAL CONTROL INTERFACE ACROSS ALL DEVICES
Increased Reliability With Reduced Part Count
Before refurbishing
Custom-built
electronics removed
Replaced with
fewer, lighter, more
reliable SEL
Compatible Inertia-based and Inverter-based
DERs
No Single Point of Failure
X
Microgrid
Controller
TMS
DDS
X
RTAC
RTAC
RTAC
30 kW
60 kW
100 kW
Wet-Stacking Correction Strategy Does Not Burn
Extra Fuel
RTAC
RTAC
RTAC
30 kW
60 kW
100 kW
Capacity
Usage
Running as Microgrid Saves Fuel
100 kW
60 kW
30 kW
30% Efficient
90% Efficient
30%
30% Efficient
120
120
120
100
100
100
80
80
80
60
60
60
40
40
40
20
20
20
0
0
0
20
40
60
80
100
120
0
0
20
40
60
80
100
120
0
20
40
60
80
100
120
Relay-Based POWERMAX Solutions
SCALE TO ANY SIZE POWER SYSTEM
SEL R&D facility
100
Military TMS
80
Control
60
functionality
in relay
40
(percent)
20
Islanded
grid size
(MW)
0
0.01
Parris Island
X
Competitors
0.1
1
10
100
Garrison
Mobile
1,000
10,000
Industrial
Commercial
Utility
POWERMAX
for Mobile
Microgrids
Distributed Control
Architecture
Microgrid
Controls and
Monitoring
EWS
SEL-3360S
MC
Genset
Controls
SEL-3530-4
IRIG-B
SDN
TMS
SEL-2401
Load
Controls
SEL-3505
SEL-3505
SEL-700G
SEL-700G
SEL-849
Governor
AVR
...
RTD/AO
Utility
POWERMAX®
for Garrison
5 MVA
Gas Turbine
1 MVA
Gas Reciprocating
Engine
GR
SRC
GT
SEL-700G
PCC
SEL-700G
SEL-3505
Microgrids
Distributed Control
Architecture
SRC
SEL-3505
SEL-751
HMI
SEL-3505
EWS
4 MVA
PV
SEL-3355
SEL-700G
SEL-3505
MC
IRIG
STOR
Battery Battery
2 MW
20 MWH
SEL-700G
SEL-2742S
SEL-3620
SEL-2407
PV
PV
Outside
LAN
SEL-3505
SDN
TMS
SEL-3555
DIST
SEL-3530-4
SEL-700 Series
SEL-700 Series
Protection
Sheddable
Feeder
Sheddable
Motor
SEL-700 Series
SEL-800
Series
Protection
Protection
Protection
Nonsheddable
Nonsheddable
Load
Motor
600 kVA
EDG
BLUE
SEL-3505
SEL-700G
SEL-751
Priority
Load
30 kVA
EDG
BLUE
SEL-3505
SEL-700G
Priority
Load
SEL-751
POWERMAX
Commercial Centralized Architecture
Visualization
Protection
Load
Management
DER
Management
PCC
Management
Cyber Security
HMI / SCADA
Events
SOEs
Coordination
Logics
Relay Settings
Priorities
Load Shed
Load Restore
V and F Control
Economics
PV and BESS
Management
IEEE 1547
Power Factor
Sync (25A)
Networking
NERC CIP
Relay-Based Solutions Scale Up to Any Size or
Complexity
of Power
System
Redundant
HMI Servers
Corporate Networks
SE L
SEL-3355
SEL-3355
SE L
Redundant
Gateways
SEL-3530
SEL-3530
SE L
SE L
Historian
Servers
Firewall
Engineering Work
Station
Redundant
Controllers
HMI
Workstations / Clients
Event / SOE
Server
Synchrophasor
Server
SE L
SEL-3555
SEL-3555
SE L
SE L
SE L
SEL-3555
SEL-3555
SE L
SE L
SEL-3555
SEL-3555
SE L
SE L
SEL-3555
SEL-3555
SEL-2730M
SE L
SE L
SEL-2730M
SE L
SE L
SEL-3555
SEL-3555
Redundant PMS LAN
Substation A
SE L
SEL-2730M
Substation B
SE L
SEL-2730M
SE L
SEL-2730M
Primary FEP
SEL-3530
SE L
SEL DPAC Remote I/O
SEL-2440
SE L
SEL-3530
SE L
SEL-751A
SEL-751A
SEL-751A
SE L
SE L
SEL Relays
SE L
SEL-2730M
SE L
SEL-2730M
Primary FEP
SEL-3530
SE L
SEL DPAC Remote I/O
SEL-2440
SE L
Backup FEP
SE L
Substation ...n
Primary FEP
SEL-3530
SE L
SEL-751A
SEL-751A
SEL-751A
SE L
SE L
SEL Relays
SEL-3530
SE L
SEL DPAC Remote I/O
SEL-2440
SE L
Backup FEP
SE L
SE L
Backup FEP
SEL-3530
SE L
SE L
SEL-751A
SEL-751A
SEL-751A
SE L
SE L
SEL Relays
SEL-2730M
cHIL Modeling For Mission Critical Systems
Frequency (pu)
Status
Controller
1
Steady-State
Droop Line
3
2
Transient Governor
Behavior
Inputs
Controller
1.0
0.96
Governor
Frequency
Set Point
Dynamic
Simulation
System
Outputs
Controls
Power (pu)
1.0
Thank you
Download