ABBREVIATIONS SYMBOLS USED AS ABBREVIATIONS INSTALLED BY COMMENTS SALES FIXTURES EXCEPT MWU BACK-LIT LIGHTS, AT&T GLOBE SIGNS LIGHT FIXTURES SALES FLOOR ONLY CEILING TILE SALES FLOOR ONLY CEILING GRID SALES FLOOR ONLY, AS NEEDED QMI CABINET (ONE) EXCLUDES BASE DEVICE ALIVE IT EQUIPMENT & UNIVERSAL MEMORY LIGHTING EXCHANGER SHOPPERTRAK AATV IT EQUIPMENT MONITOR, CPU, IT COMPONENTS MUSIC ALL CONSTRUCTION IT EQUIP. NOT LISTED ABOVE DRAWING LEGEND DESCRIPTION MASONRY WALL-BRICK (PLAN) SYMBOL B AT&T PAID; COORDINATED WITH DEALER DESCRIPTION SECTION LETTER SECTION INDICATOR SHEET INDEX DESIGN INTENT SET A0.1 GENERAL PROJECT INFORMATION A2.1 ARCHITECTURAL FLOOR PLAN A3.1 REFLECTED CEILING PLAN A6.1 INTERIOR ELEVATIONS R1.1 POWER/DATA/FLOOR BOX PLAN SHEET DRAWN ELEVATION LETTER EXTERIOR ELEVATION MARKER EXISTING SHEET DRAWN DETAIL NUMBER A. B. DETAIL REFERENCE INSULATION-RIGID SHEET DRAWN ELEVATION LETTER XX GENERAL PLAN NOTES DETAIL INDICATOR SHEET DRAWN PLYWOOD-LARGE SCALE 2014A DOOR NUMBER A. X WINDOW TYPE B. C. CASED OPENING DX PARTITION TYPE ELEVATION EARTH 100'-0" A COLUMN LINE LEVEL INDICATOR AFF D. E. POINT OF REFERENCE COLUMN GRID MARKER CUMULATIVE DIMENSION Y-134'-8" 9/26/2014 3:29:11 PM P:\Cingular\C06898.035.00 - AT&T 2400 PGA, FL DES1\Models\689835_2400 PGA_FL_2013.rvt D. SHEET DRAWN DETAIL NUMBER WOOD-ROUGH CONCRETE C. INTERIOR ELEVATION 8 MARKER - A202 - 1 KEYNOTE/EQUIPMENT, TOILET ACCESSORY AND PLUMBING SYMBOL 1 F. G. SHEET DRAWN REVISION NUMBER 1 1 SECTION LETTER BLDG SECTION ROOM NAME XXX ROOM NUMBER 2 H. NO PLAN DEVIATIONS ALLOWED UNLESS APPROVED IN WRITING BY AT&T PROJECT MANAGER. NO ELECTRICAL OUTLETS OR DATA J-BOXES BEHIND MWU SHALL BE VISIBLE. DEALER TO VERIFY IN FIELD THAT THE FLOOR PLAN LENGTH AND WIDTH DIMENSIONS ARE ACCURATE; IF DISCREPANCY EXISTS, DISCUSS WITH AT&T PROJECT MANAGER. SALES/STOCK WALL SHOULD ALWAYS EXTEND PAST SALES FLOOR CEILING HEIGHT. REMOVE ALL EXISTING STICKERS OR GRAPHICS FROM EXTERIOR GLASS (UNLESS AT&T-APPROVED). LEVEL 4 WALL FINISH ACCEPTABLE, EXISTING TEXTURE OF WALL OKAY. DATA WIRING SHOWN IS PER COR STANDARDS; DEALER REQUIREMENTS MAY DIFFER BASED UPON DEALER-PROVIDED EQUIPMENT (POS TERMINALS, PRINTERS, ETC.). VERIFY WITH DEALER WHETHER ANY ELECTRICAL OR DATA ADDITIONS ARE NEEDED FOR THE LOCATION OF THE MUSIC EQUIPMENT. 3 DESIGN INTENT NOTES GENERAL PROJECT NOTES DEMO INSULATION (LOOSE OR BATT) N NTS EXTERIOR SIGNAGE MASONRY WALL-CMU (PLAN) TYPICAL WALL (PLAN) VICINITY LOCATION MAP DSL OR T-1 SERVICE NORTH E. F. G. H. THE ARCHITECT SHALL BE NOTIFIED IMMEDIATELY OF ANY DISCREPANCIES BETWEEN THESE DOCUMENTS AND ANY APPLICABLE CODES BY THE AGENT INVOLVED WITH THE GOVERNING AGENCY HAVING JURISDICTION. IT IS UNDERSTOOD THAT THE "FIELD INSPECTOR" FOR SUCH AGENCY HAS FINAL AUTHORITY TO APPROVE / DISAPPROVE PROJECT CONSTRUCTION AND CORRECTNESS OF ALL CODE RELATED ITEMS. EACH SUBCONTRACTOR IS CONSIDERED A SPECIALIST IN THEIR RESPECTIVE FIELD OR TRADE AND SHALL NOTIFY, PRIOR TO PERFORMANCE OF THE WORK. THE GENERAL CONTRACTOR AND THE ARCHITECT OF ANY WORK CALLED OUT IN THE DRAWINGS WHICH CANNOT BE FULLY GUARANTEED OR CONSTRUCTED AS DESIGNED OR DETAILED. THE CONTRACTOR SHALL VERIFY ALL SITE CONDITIONS PRIOR TO COMMENCING THE WORK AND IMMEDIATELY NOTIFY THE ARCHITECT IN WRITING OF ANY DISCREPANCIES. THE CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND LOCATIONS OF ALL OPENINGS, BASES, AND SPECIAL PROVISIONS REQUIRED FOR EQUIPMENT, DUCTS, PIPING, CONDUITS, FINISH HARDWARE, ETC. AND IMMEDIATELY NOTIFY THE ARCHITECT IN WRITING OF ANY DISCREPANCIES. DO NOT SCALE DRAWINGS. ALL DIMENSIONS SPECIFIED SHALL GOVERN. WHERE CONSTRUCTION DETAILS ARE NOT SHOWN OR NOTED FOR ANY PART OF THE WORK, DETAILING SHALL BE THE SAME AS FOR OTHER SIMILAR FIRST CLASS WORK FOR THE TRADE INVOLVED. THE ARCHITECT SHALL BE NOTIFIED IMMEDIATELY OF ANY ALTERNATE NON-STANDARD OR UNTESTED METHOD(S) PROPOSED. GENERAL CONTRACTOR SHALL COORDINATE ARCHITECTURAL DRAWINGS WITH MECHANICAL AND ELECTRICAL, PLUMBING, CIVIL AND LANDSCAPE DRAWINGS. GENERAL CONTRACTOR SHALL MAINTAIN ALL EXISTING FIRE RATINGS DURING DEMOLITION AND CONSTRUCTION. 4 2400 PGA, FL DES 1 CARPET (SALES FLOOR ONLY) 5 1. 2. 3. 4. THESE DOCUMENTS ONLY CONTAIN INFORMATION PERTAINING TO THE ARCHITECTURAL SCOPE-OF-WORK. FOR THIS PROJECT, ENGINEERING DESIGN, DOCUMENTS AND SPECIFICATION PREPARATION, AS REQUIRED FOR ALL OTHER DISCIPLINES, HAVE BEEN PREPARED BY OTHERS AND ARE NOT THE REPONSIBILITY OF THE ARCHITECT / BRPH. INFORMATION INDICATED ON THESE DRAWINGS / DOCUMENTS SHOWING OR REFERENCING MECHANICAL, ELECTRICAL, PLUMBING OR FIRE PROTECTION INFORMATION, WHERE IT OCCURS, HAS BEEN PROVIDED FOR REFERENCE ONLY. THE ENGINEERING DESIGNERS, AS LICENSED AND QUALIFIED PROFESSIONALS UNDER CONTRACT TO OTHERS, SHALL REMAIN SOLELY RESPONSIBLE FOR ALL DESIGN AND APPLICABLE CODE COMPLIANCE MATTERS RELATIVE TO THEIR RESPECTIVE DISCIPLINES. THIS SHALL INCLUDE ADDRESSING AND RESOLVING ANY PLAN REVIEW COMMENTS RELATIVE TO THEIR SPECIFIC SCOPE-OF-WORK. THE PROJECT ENGINEERING DESIGNERS SHALL ENDEAVOR TO BRING TO THE ATTENTION OF THE ARCHITECT / BRPH ANY DESIGNCHANGE OR CODE COMPLIANCE ITEMS IMPACTING THE ARCHITECTURAL SCOPE-OF-WORK AS EXPEDITIOUSLY AS POSSIBLE. SE REGION PROJECT SITE 2400 PGA BLVD, PALM BEACH GARDENS, FL 33410 ITEM REVISION DEALER FURNISHED BY FINAL DESIGN INTENT SET ISSUE PROJECT LOCATION - VICINITY DATA CABLING SYMBOL These plans are protected by Federal Copyright protection. Unauthorized use may result in an infringement action. RESPONSIBILITY SCHEDULE AT&T VENDOR TYPICAL UNLESS NOTED OTHERWISE URINAL VERTICAL VINYL WALL COVERING VINYL COMPOSITION TILE WATER CLOSET WELDED WIRE FABRIC WIDTH, WIDE WIDE FLANGE WITHOUT WOOD 2014 Offices in Melbourne, Orlando, West Palm Beach, Atlanta, Charleston, Seattle 2400 PGA, FL DES 1 WS AT&T ELECTRIC (AL) ELECTRIC WATER COOLER ELEVATION ENCLOSE (URE) TYP UNO UR VERT VWC VCT WC WWF W WF WO WD & GC ELEC EWC EL ENCL HT H HM HOR HB INCL ID INSUL INT INV JAN JT LBL LAM LAV LH LT MB MFR MAS MO MAT'L MAX MECH MTL MIN MISC MT MTD NOM NIC NTS NSG NO OC OPG OPP OD © 2727 Paces Ferry Road | Bldg 1 | Suite 1800 Atlanta | Georgia | 30339 770-933-9242 | 770-933-9246 f AT&T MOBILITY C ABOVE FINISHED FLOOR ACCESS PANEL ADJUSTABLE ALTERNATE ALUMINUM ANCHOR BOLT ANODIZED APPROXIMATE ARCHITECT(URAL) AREA DRAIN BASEMENT BEARING BEAM BETWEEN BLOCK BLOCKING BOARD BOTH WAYS BOTTOM BUILDING CABINET CARPET (ED) CAST IRON CAST-IN-PLACE CEILING CERAMIC TILE CLEAR (ANCE) CLOSET COLUMN COMBUSTIBLE CONCRETE CONCRETE MASONRY UNIT CONSTRUCTION CONTINUOUS CONTRACT (OR) CONTROL JOINT CORRUGATED COURSE (S) DETAIL DIAGONAL DIAMETER DIMENSION DITTO DOOR DOUBLE DOWNSPOUT DRAWING DRINKING FOUNTAIN EACH EACH FACE EXPANSION JOINT Copyright Architects, Engineers, Constructors ARCHITECT D AFF AP ADJ ALT ALUM AB ANOD APPROX ARCH AD BSMT BRG BM BTWN BLK BLKG BD BW BOT BLDG CAB CPT CI CIP CLG CT CLR CLO COL COMB CONC CMU CONST CONT CONTR CJ CORR CRS DTL DIAG DIA DIM DO DR DBL DS DWG DF EA EF EJ www.brph.com DEALER E OVERALL OVERHEAD PAINT (ED) PAIR PANEL PLASTER PLASTIC LAMINATE PLATE PREMOLDED EXPAN. JOINT PLYWOOD PORTLAND CEMENT POWER POLE QUANTITY QUARRY TILE RADIUS REFERENCE REINFORCE (D) (ING) REQUIRED REVERSE (SIDE) RIGHT HAND RIGHT OF WAY RISER ROOF DRAIN ROOM ROUGH OPENING RUBBER BASE SUSPENDED ACOUSTICAL TILE SECTION SHEET SIMILAR SPECIFICATION (S) SQUARE STAINLESS STEEL STANDARD STEEL STORAGE STRUCTURAL TELEPHONE TERRAZZO THICK TONGUE AND GROOVE TOP AND BOTTOM TOP OF CONCRETE TOP OF STEEL TOP OF WALL TREAD TUBE STEEL AT&T VENDOR ARCHITECTURAL OA OH PT PR PNL PLAS PLAM PL PMJ PWD PC PP QUAN QT RAD REF, RE: REINF REQ REV RH ROW R RD RM RO RB SAT SECT SHT SIM SPEC SQ ST STL STD STL STO STRUCT TEL TZ THK T&G T&B TOC TOS TOW T T/S AT&T PROPERTY LINE EQUAL EQUIPMENT EXHAUST EXISTING EXPANSION BOLT EXPANSION JOINT EXTERIOR FINISH (ED) FIRE EXTINGUISHER FIRE HOSE CABINET FLOOR (ING) FLOOR DRAIN FOOTING FOUNDATION FRAME FRAME OPENING FIELD VERIFY GAGE, GAUGE GALVANIZED GENERAL CONTRACT (OR) GLASS, GLAZING GYPSUM WALL BOARD HARDWARE HEATING HEATING/VENTILATION/ AIR CONDITIONING HEIGHT HIGH HOLLOW METAL HORIZONTAL HOSE BIB INCLUDE (D) (ING) INSIDE DIAMETER INSULATE (D) (ING) INTERIOR INVERT JANITOR JOINT LABEL LAMINATE (D) LAVATORY LEFT HAND LENGTH MACHINE BOLT MANUFACTURE (ER) MASONRY MASONRY OPENING MATERIAL (S) MAXIMUM MECHANIC (AL) METAL MINIMUM MISCELLANEOUS MOUNT MOUNTED NOMINAL NOT IN CONTRACT NOT TO SCALE NON-SHRINK GROUT NUMBER ON CENTER OPENING OPPOSITE OUTSIDE DIAMETER GC PL EQ EQUIP EXH EXIST EXP BOLT EXP JT EXT FIN FE FHC FL FD FTG FND FR FO FV GA GALV GC GL GWB HDWE HTG HVAC A/C ARCHITECT O ANGLE CENTERLINE PERPENDICULAR ROUND OR DIAMETER Y NL O N T EN CTIO T IN RU N T SIG ONS E R D OR C O F TF NO ARCH/ENGR OF RECORD BRUCE A. LOTT DESIGNED BY BDR DRAWN BY BUILDING AREA KCC CHECKED BY BAL TOTAL STORE AREA: 1,630 SF PROJECT NUMBER TOTAL RETAIL AREA: 1,212 SF C06898.035.00 TOTAL BOH AREA: AREA RATIO: 418 SF 74% RETAIL 26% BACK OF HOUSE DEALER CONTACT NAME: Nadir Panjwani PHONE: 404-394-7474 EMAIL: nadir@globalsolutions.at 6 DATE 09/26/14 TITLE GENERAL PROJECT INFORMATION DRAWING NO. A0.1 SIDEWALK W/PARKING BEYOND 14' - 0" 6' - 7" EXISTING 3' - 10" 4' - 11" 6" 4' - 10" 14' - 0" 40" 4' - 11" iPad iPhone 6" 4' - 11" 14' - 0" 34" 4' - 11" HERO WEAR 6" 4' - 11" 6" 12' - 4 1/4" 4' - 11" 6" FLOOR PLAN GENERAL NOTES 4' - 11" SP&T SP&T SP&T SP&T E BP BP E ACC-DIA MWU-D MWU-D MWU-D MWU-D BCW-MED 2 AATV-BENCH 1 5' - 5 1/2" MPOS A6.1 AATV-SML 3 2 4 SALES 9' - 1" MPOS-ADA 1' - 8 3/4" OF SALES FLOOR & BCW LT-S LT-S LT-D-ADA LT-S-ADA LT-S-ADA 101 1 ± 18' - 8" EXISTING 2 4 2 1212 SF 3' - 9" 6" 2 3' - 9" ACC-LRG 3 OF AATV LT-D 44"X86" Sm Comm Table E 103 MWU-D ACC-SML EQ 4' - 6" MWU-D MWU-D MWU-D 5 MWU-D WIN-B 18" 6" 6" 3' - 10" EXISTING E BP BP D SIDEWALK W/PARKING BEYOND 3 MWU-D EQ 7' - 5" EXISTING BOH IP-D MWU-D 102 GC TO INSTALL FIRE RETARDANT BLOCKING AS REQUIRED FOR ALL CASEWORK, SHELVING, COUNTERTOPS, & OWNER PROVIDED EQUIPMENT. B. PATCH CONCRETE SLAB AS REQUIRED TO REPAIR CONDUIT INSTALLATION. SEE ELECTRICAL FOR EXTEND OF SLAB TRENCHING. C. ALL DIMENSIONS ARE FINISH TO FINISH UNLESS NOTED OTHERWISE. D. MAINTAIN EXISTING FIRE RATINGS AT TENANT SEPARATION WALLS DURING DEMO / CONSTRUCTION ACTIVITIES. E. SEE REFLECTED CEILING PLAN ON SHEET A3.1 FOR ACT LAYOUT. F. ALL MILLWORK / CABINETRY PROVIDED BY FIXTURE VENDOR. G. SEE INTERIOR ELEVATIONS ON SHEET A6.1 FOR ALL WALLS WHERE NO FINISH OR BASE IS INDICATED. H. PAINT ALL SALES FLOOR DOORS AND FRAMES (ALUMINUM STOREFRONT NOT INCLUDED) TO MATCH ADJACENT WALL COLOR, USING A SEMI-GLOSS FINISH UNLESS NOTED OTHERWISE. AT&T 7' - 7" TOILET A. www.brph.com Copyright 2014 Architects, Engineers, Constructors 2727 Paces Ferry Road | Bldg 1 | Suite 1800 Atlanta | Georgia | 30339 770-933-9242 | 770-933-9246 f Offices in Melbourne, Orlando, West Palm Beach, Atlanta, Charleston, Seattle These plans are protected by Federal Copyright protection. Unauthorized use may result in an infringement action. FINAL DESIGN INTENT SET ISSUE REVISION FLOOR PLAN KEY NOTES 1 CENTERLINES ARE USED TO LAYOUT STORE, INCLUDING CEILING, POWER / DATA, FIXTURES, ETC. AND MUST BE MARKED AND VARIFIED PRIOR TO START OF CONSTRUCTION. CONTACT ARCHITECT IMMEDIATELY IF THERE ARE DIMENSIONAL DISCREPANCIES. 2 LIGHT FIXTURE ABOVE - SEE RCP FOR LOCATION AND ADDITIONAL INFORMATION. 3 BOH SHOWN FOR REFERENCE ONLY AND BY OTHERS, N.I.C. 4 CENTER THIS FIXTURE ON 5 ADJUST LOCATION OF POSTER RAILS AS PER ACTUAL FIELD LOCATION OF EXTERIOR GLASS AND WINDOW MULLIONS. E 6" 4' - 11" 8" 8" 4' - 11" GO 6" 4' - 11" 40' - 4 1/4" SIDEWALK W/PARKING BEYOND ± 80' - 8 1/2" EXISTING FLOOR PLAN QTY 1 1 1 1 1 1 1 6 1 1 1 2 2 1 1 11 1 1 WALL & DOOR LEGEND DIMENSION POINT NOTE: TOP OF CONCRETE ALL FIXTURES, EXCLUDING AATV TO BE RELOCATED FROM PGA TEMPERARY LOCATION TO BE USED WHEN POSSIBLE. NEW CONSTRUCTION WALL EXISTING WALL TO REMAIN STOREFRONT GLAZING . . . EXISTING DOOR TO REMAIN . . . . . . . . . . . . E . 1/32" . . .. . . . . . 5/16". .. .. . . . . . . GLUE-DOWN CARPET .. . . C VINYL EDGE STRIP-JOHNSONITE CE-XX-A, COLOR 63 BURNT UMBER VCT FLOORING JOHNSONITE MTC-00-A NEW CONSTRUCTION DOOR 6" 3 A2.1 FIXTURE AATV-BENCH AATV-SML ACC-DIA ACC-LRG ACC-SML AT&T BCW-MED BP IP-D LT-D LT-D-ADA LT-S LT-S-ADA MPOS MPOS-ADA MWU-D Sm Comm Table WIN-B DESCRIPTION AATV BENCH AATV Small DIAMOND ACCESSORY FIXTURE ACCESSORY FIXTURE ACCESSORY FIXTURE AT&T LOGO BACKWRAP Blocker Panel L3 - 60" IPHONE FIXTURE LEARNING TABLE ADA LEARNING TABLE LEARNING TABLE STOOL ADA LEARNING TABLE STOOL MOBILE POINT OF SALE MOBILE POINT OF SALE LEVEL 3 MERCHANDISE UNIT SMALL COMMUNITY TABLE WINDOW BANNER FLOORING TRANSITION 1 1/2" = 1'-0" 2400 PGA, FL DES 1 FIXTURE SCHEDULE 1/4" = 1'-0" AT&T MOBILITY 2 A2.1 BAMS AREA OF WORK SCOPE FINISH LEGEND ACT-1 102 ACT-2 P-1 VCT-1 RB-1 P-4 TO 8'-0" AFF P-1 ABOVE 8'-0" AFF RB-1 BOH 103 ACT-2 P-1 CPT-2 RB-1 PAINT COLUMN P-2 RB-1 QUARTER-TURNED CARPET LAYOUT PAINT COLUMN P-2 RB-1 ACT-1 CPT-1 SALES 101 1212 SF P-1 EXCLUDING STOREFRONT RB-1 6' - 0" 4' - 0" P-4 TO 8'-0" AFF P-1 ABOVE 8'-0" AFF RB-1 B 9/26/2014 3:29:13 PM BENJAMIN MOORE "WEDDING VEIL" #2125-70 EGGSHELL ON WHITE GWB WALLS & SOFFITS P-2 BENJAMIN MOORE "SWEET INNOCENCE" #2125-50 EGGSHELL ON LIGHT GREY GWB WALLS, SALES FLOOR GWB COLUMNS, & ACT CEILING ACCESSORIES SEMI-GLOSS ON LIGHT GREY DOORS, FRAMES ALTERNATIVE: SHERWIN WILLIAMS "UPWARD" #SW 6239 EGGSHELL ON LIGHT GREY GWB WALLS, SALES FLOOR GWB COLUMNS, & ACT CEILING ACCESSORIES SEMI-GLOSS ON LIGHT GREY DOORS, FRAMES P-4 BENJAMIN MOORE "ORANGE BURST" #2015-20 FGGSHELL ON ORANGE GWB WALLS & SOFFITS SEMI-GLOSS ON ORANGE DOORS & FRAMES ALTERNATIVE: SHERWIN WILLIAMS "INVIGORATE" #SW 6886 FGGSHELL ON ORANGE GWB WALLS & SOFFITS SEMI-GLOSS ON ORANGE DOORS & FRAMES CPT-1 CPT-3 AREA OF WORK SCOPE 1 A2.1 P-1 CPT-3 A VCT-1 FINISH PLAN RB-1 1/4" = 1'-0" ACT-2 USG RADAR CLIMAPLUS #2420 EDGE: SLT SIZE: 2 X 4 COLOR: FLAT WHITE GRID: DONN DX 15/16" GRID COLOR: FLAT WHITE 800-950-3839 ALTERNATIVE: SHERWIN WILLIAMS "EXTRA WHITE" #SW 7006 EGGSHELL ON WHITE GWB WALLS & SOFFITS TOILET P-4 TO 8'-0" AFF P-1 ABOVE 8'-0" AFF RB-1 PROVIDE TRANSITION STRIP IF DISSIMILAR FLOOR FINISH. SEE 3/A2.1 FOR REFERENCE USG FROST CLIMAPLUS #414 EDGE: SLB SIZE: 2 X 2 COLOR: SILVERTONE #052 GRID: DONN DX 15/16" GRID COLOR: SILVERTONE 800-950-3839 MFR: SHAW CARPET STYLE: ATT HIGH S[EED SQUARE #4546V COLOR: #BLUE STREAK #M5556 CONSTRUCTION: MULTI-SCROLL 1/4 TURN PATTERN: NO REPEAT INSTALL CONTACT: MARK LAW 770-241-1345 MFR: SHAW. STYLE: C0149 CINGULAR ENTRY COLOR: JET BLACK JB210 TYPE: 24" X 24" TILE MULTILEVEL LOOP MARK LAW, 770-241-1345 2 3 4 5 ARCH/ENGR OF RECORD BRUCE A. LOTT BDR DRAWN BY KCC CHECKED BY BAL PROJECT NUMBER C06898.035.00 1/4 TURN INSTALL DATE 09/26/14 TITLE ALTERNATIVE SUPPLIER: GRAINGER ANDREW DODSON 404-806-8263, andrew.dodson@grainger.com ALSO COPY NOEL WELLS noel.wells@grainger.com NOTE: THE FRONT AND SIDES OF THE BACKWRAP FIXTURE (BCW) SHALL RECEIVE RB-1, AND THE FRONT AND SIDES OF AATV WALL FIXTURE (AATV) SHALL RECEIVE RB-1 1 Y NL O N T EN CTIO T IN RU N T SIG ONS E R D OR C O F TF NO DESIGNED BY ARMSTRONG IMPERIAL TEXTURE #51904 STERLING 12"x12"x 1/8" JOHNSONITE 82 BLACK PEARL SIZE: 4" (COVE BASE) (ROLL PRODUCT) MIKE MATSON 253-395-3639 SE REGION 4' - 11" ACC OF Sm Comm Table OF SALES FLOOR. 2400 PGA BLVD, PALM BEACH GARDENS, FL 33410 WHP P:\Cingular\C06898.035.00 - AT&T 2400 PGA, FL DES1\Models\689835_2400 PGA_FL_2013.rvt © 6 ARCHITECTURAL FLOOR PLAN DRAWING NO. A2.1 RCP GENERAL NOTES A. LIGHT SWITCHES TO BE MOUNTED AT 42" AFF, UNO. E B. SEE FINISH LEGEND FOR ACOUSTICAL CEILING PANEL INFORMATION ON SHEET A2.1 www.brph.com C. LIGHT FIXTURS ARE TO BE CENTERED ON CEILING PANELS, UNO. Architects, Engineers, Constructors D. CONTACT ARCHITECT TO COORDINATE LIGHT FIXTURE LOCATIONS IF EXISTING CEILING GRID IS TO BE RE-USED. 2727 Paces Ferry Road | Bldg 1 | Suite 1800 Atlanta | Georgia | 30339 770-933-9242 | 770-933-9246 f E. ALL LIGHT FIXTURES ARE TO BE ORDERED THROUGH CRAINGER PER NATIONAL AGGREEMENT. VERIFY QUANTITIES PRIOR TO ORDER. F. 14' - 0" 14' - 0" 12' - 4 1/4" ACT-2 EQ EQ 9' - 0"AFF H. PROVIDE 100 LUMEN BATTERY BACKUPS IN EMERGENCY FIXTURES WHERE INDICATED ON DRAWINGS. J. 3 8 F16 F16 F16 8 8 F4A F4A F16 8 8 F4A L. 5 F4A OF SALES FLOOR & BCW 7 ACT-1 F12 F12 OF AATV 7 10' - 0"AFF 4 F16 EM 8 8 F4A F4A 3' - 0" F4A F16 9 8 F16 F16 CENTERLINES ARE USED TO LAYOUT STORE, INCLUDING CEILING, POWER / DATA, FIXTURES, ETC. AND MUST BE MARKED AND VARIFIED PRIOR TO START OF CONSTRUCTION. CONTACT ARCHITECT IMMEDIATELY IF THERE ARE DIMENSIONAL DISCREPANCIES. 2 F4A IN FRONT OF THE POSTER RAILS THAT THEY SHOULD BE CENTERED WITHIN THE LENGTH OF THE RAILS. 3 BOH SHOWN FOR REFERENCE ONLY AND BY OTHERS, NIC. 4 SURFACE MOUNTED LIGHT FIXTURE 5 FIXTURE BELOW - REFER TO A2.1 FOR MORE INFORMATION AND EXACT PLACEMENT. 6 NEW CEILING GRID AND TILE FOR THIS SPACE. 7 LIGHT TO SHINE ON FIXTURE BELOW. 8 LIGHT TO BE CENTERED ON FIXTURE BELOW. GC TO AIM LIGHT ON CENTER SHELF OF MWU (IF APPLICABLE) - REFER TO SHEET A2.1 FOR FIXTURE PLACEMENT INFORMATION. 9 EMERGENCY LIGHTS ARE SHOWN FOR REFERENCE ONLY, AND ARE THE RESPONSIBILITY OF THE ARCHITECT AND / OR ENGINEER OF RECORD TO DETERMINE FINAL LOCATION AND QUANTITY. 10 PREFERRED LOCATION FOR LIGHTING SWITCH. F16 F4A 3' - 0" 3' - 0" OF SM COMM TBL AREA OF WORK SCOPE 1 A3.1 X 1 2 9 C RCP KEY NOTES 5 F4A 3' - 0" 8 F4A F4A 6 F4A F16 4 4 4 10 F12 F12 OF BCW 4" 1 F4A CONTRACTOR TO USE MANUFACTURER-PROVIDED SPACERS FOR INSTALLATION OF F12 DOME LIGHTS WHEN INSTALLING TO A LAY-IN CEILING WITH TEGULAR TILES.. F4A 7 1' - 8 3/4" F16 8 F4A 5 3 F16 EM F4A 8 8 9' - 0"AFF D F4A F4A 1' - 6" 1' - 6" ACT-2 F4A F4A REFLECTED CEILING PLAN F4A LIGHT FIXTURE 1/4" = 1'-0" ACT-1 CEILING REFLECTED CEILING PLAN LEGEND BANNER RAIL BY FIXTURE SUPPLIER 2' X 2' SUPPLY DIFFUSER EXISTING EXTERIOR WALL SE REGION F4A REVISION 2400 PGA BLVD, PALM BEACH GARDENS, FL 33410 F4A FINAL DESIGN INTENT SET 2400 PGA, FL DES 1 F4A These plans are protected by Federal Copyright protection. Unauthorized use may result in an infringement action. ISSUE CENTER ACT AND GRID IN SPACE UNO.. K. ALL CEILING LIGHTS (OTHER THAN NOTED EM'S) SHOULD BE SWITCHED. THE EXCEPTIONS WOULD BE THE MONOPOINT F4A LIGHTS IN THE FRONT STOREFRONT THAT SHINE LIGHT ON THE WALL BANNERS IN THE WINDOWS. THESE SHOULD BE TIED TO THE EXTERIOR SIGN TIMER SO THAT THEY COME ON AND LIGHT THE GRAPHICS ONLY WHEN DARK. OTHER THAN THIS, AT LEAST ONE PLUG BEHIND EACH MWU (PER PLAN) NEEDS TO BE ON A LIGHT SWITCH (WITH A DEDICATED SWITCH OR TWO FOR THIS LOCATED WITH THE OTHER SWITCHES ON A MAIN SWITCHBANK). PREFERRED LOCATION OF SWITCHBANK IS ON STOCKROOM SIDE OF SALES / STOCK WALL. 3' - 0" 9 2014 ALL EXISTING DIFFUSERS & RETURN GRILLES ARE TO REMAIN IF APPLICABLE. PAINT ALL DIFFUSERS & RETURN GRILLES ON ACT-1 CEILING AT SALES FLOOR P-2. G. NOT ALL LIGHT FIXTURES MAY BE USED ON THIS PROJECT. GC TO VERIFY LIGHT QUANTITIES AND FIXTURES WITH QUANTITIES LISTED ON DRAWINGS. 2' - 0" © Offices in Melbourne, Orlando, West Palm Beach, Atlanta, Charleston, Seattle AT&T MOBILITY 14' - 0" Copyright 2' X 2' RETURN 6" 6" 1' - 2" 4" B 2' X 4' FLUORESCENT LIGHT 3 A3.1 J1 Y NL O N T EN CTIO T IN RU N T SIG ONS E R D OR C O F TF NO SECTION @ PROMOTIONAL POSTER 1 1/2" = 1'-0" 1' X 4' FLUORESCENT LIGHT F16 EXIT LIGHT INDEPENDENT LIGHT FIXTURE SUPPORT WIRE PER CODE EXIT 3 F4A 23 F12 4 A F16 10 F16EM 2 LITHONIA COOPER HALO STATIS LITE ENERGY / LIGHTOLIER COOPER COOPER LAMPS MODEL MANUFACTURER QTY. # EDG 1 120 ELN * L50516-20CMH-P-L111-LM50516-L973-AH CANOPY LE/CS-44120-4XF25T8-120 1 4 METALUX GC332-UNV-EB81-U-1X4 MILK WHITE LENS FGW080 3 METALUX GC332-120-FBP24H-EB81-U-1X4 MILK WHITE LENS FGW080 3 CAT. NO. LED GE CMH20MR16/830/FL GE F25/T8/SPX35/ECO GE F32W/T8/SPX35 GE F32W/T8/SPX35 VOLT SINGLE-FACE EDGE LIT EXIT SIGN WITH BATTERY (VERIFY LED COLOR PER LOCAL CODE) 120 CANOPY MOUNTED CMH MR16 MONOPOINT ACCENT LIGHT, LOCKING TILT AND ROTATION, ON-OFF SWITCH, ALUMINUM DIE-CAST HOUSING WITH VERTICAL ELECTRONIC BALLAST, SOFT FOCUS LENS AND HOLDER, SQUARE MONOPOINT CANOPY ACCESSORY, ALUMINUM HAZE FINISH 120 120 2 DESIGNED BY BDR INDEPENDENT SUPPORT CLIP W/ THREADED STUD & NUT ATTACHMENT ERICO PART NO. IDS OR EQUILIVENT. MIN 4 PER FIXTURE DRAWN BY RECESSED ADJUSTABLE MR16 METAL HALIDE F2, F2A KCC CHECKED BY BAL PROJECT NUMBER CANOPY MOUNTED CMH MR16 MONOPOINT ACCENT LIGHT, LOCKING TILT AND ROTATION, ON-OFF SWITCH, ALUMINUM DIE-AST HOUSING WITH VERTICAL ELECTRONIC BALLAST, SOFT FOCUS LENS AND HOLDER, SQUARE MONOPOINT CANOPY ACCESSORY, WHITE FINISH. CENTER LIGHT AS CLOSE AS POSSIBLE ON MWU. 48" DIAMETER LARGE SCALE SURFACE MOUNTED LUMINAIRE WITH WHITE ACRYLIC DIFFUSER, 20 GAUGE DIEFORMED STEEL HOUSING, ELECTRONIC BALLAST(S), POLYESTER POWDER COAT MATTE WHITE FINISH 1'X4' RECESSED FLUORESCENT DIRECT LIGHT, HIGH REFLECTANCE WHITE POWDER COAT PAINT FINISH, TEXTURED FRONT GLAZE ACRYLIC LENS, STANDARD FLANGE DESIGN WORKS WITH MOST LAY-IN CEILINGS, BACK-UP BATTERY PACK F12 LIGHT FIXTURE SECTION @ F12 LIGHT FIXTURE DATE 09/26/14 REFLECTED CEILING PLAN F12 DRAWING NO. 1 1/2" = 1'-0" 4 4 FT DIAMETER SURFACE MOUNTED FLUORESCENT FIXTURE C06898.035.00 TITLE F4, F4A 1'X4' RECESSED FLUORESCENT DIRECT LIGHT, HIGH REFLECTANCE WHITE POWDER COAT PAINT FINISH, TEXTURED FRONT GLAZE ACRYLIC LENS, STANDARD FLANGE DESIGN WORKS WITH MOST LAY-IN CEILINGS, BACK-UP BATTERY PACK 3 ARCH/ENGR OF RECORD SPRINKLER HEAD 2 A3.1 1 F3, F3A BRUCE A. LOTT DESCRIPTION MT 120 RECESSED CAN LIGHT S COUNT MARK 9/26/2014 3:29:14 PM P:\Cingular\C06898.035.00 - AT&T 2400 PGA, FL DES1\Models\689835_2400 PGA_FL_2013.rvt LIGHTING FIXTURE SCHEDULE 5 A3.1 LIGHT SWITCH 6 CEILING 10' - 0" P-1 www.brph.com P-1 Copyright © 2014 Architects, Engineers, Constructors 2727 Paces Ferry Road | Bldg 1 | Suite 1800 Atlanta | Georgia | 30339 770-933-9242 | 770-933-9246 f WIN-B E MWU-D P-1 P-1 MWU-D MWU-D MWU-D Offices in Melbourne, Orlando, West Palm Beach, Atlanta, Charleston, Seattle 2 P-1 These plans are protected by Federal Copyright protection. Unauthorized use may result in an infringement action. P-1 RB-1 RB-1 FINAL DESIGN INTENT SET ISSUE FINISH FLOOR 0' - 0" RB-1 4 A6.1 RB-1 REVISION ELEVATION @ SALES FLOOR 4 3/8" = 1'-0" ELEVATION GENERAL NOTES OF BCW CEILING 10' - 0" P-1 P-1 A. PROVIDE FIRE RETARDANT TREATED BACKING / BLOCKING IN WALL AS REQUIRED. GC TO COORDINATE BACKING / BLOCKING FOR ALL FIXTURE VENDOR PROVIDED ITEMS. B. FOR ADDITIONAL FIXTURE INFORMATION, SEE A2.1 C. REFER TO FINISH LEGEND ON A2.1 FOR FINISH DESIGNATIONS. P-1 4' - 4" D 4' - 2 1/2" PAINT LINE 8' - 0" BCW-MED P-4 P-4 ELEVATIONS KEY NOTES RB-1 1 FINISH FLOOR 0' - 0" GC TO INSTALL RUBBER BASE (RB-1) @ BOTTOM OF FIXTURE AFTER BEING INSTALLED BY FIXTURE VENDOR ELEVATION @ SALES FLOOR 3 AT&T MOBILITY 3/8" = 1'-0" C CEILING 10' - 0" P-1 P-1 P-1 P-1 PAINT LINE 8' - 0" P-4 IP-D MWU-D MWU-D MWU-D MWU-D MWU-D P-4 P-4 MWU-D P-4 P-4 7' - 0" P-4 MWU-D 2400 PGA, FL DES 1 3 R1.1 1 3 A6.1 X RB-1 RB-1 SE REGION RB-1 2400 PGA BLVD, PALM BEACH GARDENS, FL 33410 P-4 FINISH FLOOR 0' - 0" B 2 A6.1 ELEVATION @ SALES FLOOR 2 Y NL O N T EN CTIO T IN RU N T SIG ONS E R D OR C O F TF NO 3/8" = 1'-0" CEILING 10' - 0" P-1 P-1 ARCH/ENGR OF RECORD BRUCE A. LOTT AATV-SML DESIGNED BY BDR DRAWN BY KCC P-4 CHECKED BY BAL P-4 PROJECT NUMBER C06898.035.00 EQ A EQ DATE 09/26/14 RB-1 1 A6.1 1 2 TITLE RB-1 1' - 6" 9/26/2014 3:29:15 PM P:\Cingular\C06898.035.00 - AT&T 2400 PGA, FL DES1\Models\689835_2400 PGA_FL_2013.rvt PAINT LINE 8' - 0" INTERIOR ELEVATIONS FINISH FLOOR 0' - 0" 1 ELEVATION @ SALES FLOOR 1 DRAWING NO. A6.1 3/8" = 1'-0" 3 4 5 6 FLOOR PLAN GENERAL NOTES 7' - 9" 5' - 5" 5' - 5" 5' - 5" 3' - 0" E 3' - 0" 18" 18" 18" (2D) 18" 18" (2D) 18" 18" 18" 18" (2D) 18" 18" B. ELECTRICAL INFORMATION SHOWN FOR REFERENCE ONLY. REFERENCE ELECTRICAL DRAWINGS FOR ENGINEERING DESIGN INFORMATION. C. DATA OUTLET INFORMATION SHOWN FOR LOCATION REFERENCE ONLY. REFERENCE ELECTRICAL DRAWINGS FOR ADDITIONAL INFORMATION. 7 7 7 7 7 7 13 (4D+1T)18" 7' - 4" 6 5 6' - 3 1/4" 3 PROVIDE PULL STRINGS IN ALL VOICE / DATA OUTLET CONDUIT. E. GROMMIT LOCATIONS TO BE COORDINATED THROUGH GC WITH OWNER. F. SAWCUT AND REMOVE EXISTING SLAB SHOWN FOR NEW MEP WORK. COORDINATE LOCATIONS ON FIXTURE AND MEP DRAWINGS. PATCH AND REPAIR FLOORING AS NOTED. GC TO COORDINATE WITH LANDLORD'S ON-SITE REPRESENTATIVE PRIOR TO CUTTING OR DRILLING EXISTING SLAB. G. ALL FACEPLATES, PLUG AND SWITCHES SHOULD BE WHITE. THEY SHOULD NOT BE PAINTED. H. REUSING EXISTING SWITCHBANK IS OKAY AS LONG AS THE SWITCHES AND FACEPLATES ARE WHITE (OR REPLACED TO BE WHITE). IF NOT EXISTING, THEN LOCATE NEW SWITCHBANK ON STOCKROOM SIDE OF SALES/STOCK WALL. 18" 3' - 9" 15 8 T 7' - 8" 7 7 5 D (2D) 18" 18" 18" 12 L. CONTRACTOR TO PROVIDE LABELING FOR THE DUAL SWITCHED/NON-SWITCHED ELECTRICAL OUTLETS BEHIND THE MWU'S. 18" 6 (4D+1T)18" 7 2 FLOOR PLAN KEY NOTES 5 (2D) 18" 18" 11 18" AREA OF WORK SCOPE 1 R1.1 4' - 9" EQ EQ 1' - 6" CENTERLINES ARE USED TO LAYOUT STORE, INCLUDING CEILING, POWER / DATA, FIXTURES, ETC. AND MUST BE MARKED AND VARIFIED PRIOR TO START OF CONSTRUCTION. CONTACT ARCHITECT IMMEDIATELY IF THERE ARE DIMENSIONAL DISCREPANCIES. 2 PROMOTIONAL POSTER RAILS PROVIDED BY FIXTURE VENDOR, PROMOTIONAL POSTER PROVIDED BY OTHERS. 3 BOH SHOWN FOR REFERENCE ONLY AND BY OTHERS, NIC. 4 NOT USED. 5' - 5" 3' - 0" 5 CONVENIENCE ELECTRICAL OUTLETS SHOWN MAYBE RELOCATED OR ELIMINATED AS PER DEALER DIRECTION. POWER/COMMUNICATIONS REFERENCE PLAN 6 FLOOR SAW CUTTING, CONCRETE REMOVAL, INSTALLATION OF DOWELS & WIRE MESH REINFORCING, REPOURING 4" CONCRETE SLAB SHALL BE BY THE GC. TRENCHING, INSTALLATION OF CONDUITS, BACKFILLING & COMPACTION OF BACKFILL BY ELECTRICAL CONTRACTOR. 4" CONCRETE SLAB SHALL BY DOWELLED INTO EXISTING SLAB WITH #5 DOWELS, 6" INTO EXISTING SLAB AND EXTEND 1'-0" INTO NEW SLAB POUR. THE NEW SLAB WIRE MESH REINFORCEMENT TO 1'-0" SECTION OR DOWEL STICKING OUT OF EXISTING SLAB. REFERENCE SHEET R1.1 FOR FLOOR BOX / STUB-UP LOCATIONS. 7 PROVIDE DUAL BRANCH CIRCUIT FOURPLEX RECEPTACLE; 2 OUTLETS SWITCHED (CONTROL FIXTURE LIGHTING), 2 OUTLETS HOT - PROVIDE BLACK ADHESIVE LABEL WITH 1/4" LETTERING INDICATING "SWITCHED FOR LTG" ADHERED TO THE HALF OF THE FOURPLEX PROVIDING POWER TO SWITCHED LIGHTING. 8 FIXTURE LIGHTS BEHIND AATV WALL MONITORS TO BE NIGHT LIGHTS. 9 RECEIPT PRINTER, 24" AFF DEDICATED CIRCUIT (MULTIPLE PRINTERS CAN SHARE THE SAME CIRCUIT). 10 NOT USED. 11 PROVIDE ONE OUTLET CENTERED ON DISPLAY ELEMENT (WINDOW BANNER). MOUNT TO CEILING ABOVE DISPLAY ELEMENT OR TO ADJACENT WALL ABOVE STOREFRONT WINDOWS AS NEEDED (SEE REFERENCE PLANS). ADD ADDITIONAL OUTLETS AS REQUIRED PER CODE. 12 2 DATA PORT IN CEILING FOR SHOPPERTRAK, FURNISHED AND INSTALLED BY OTHERS. CENTER OVER ENTRY DOOR. 13 DEDICATED 20 AMP CIRCUIT FOR THE ELECTRICAL BEHIND BACKWRAP. 14 NOT USED. 15 1 DATA PORT IN CEILING FOR WIFI ACCESS POINT. DEALER TO HAVE AVAILABLE DUPLEX ELECTRICAL OUTLET IN "BACK OF HOUSE" AREA FOR WIFI EQUIPMENT; DEALER TO MARK LOCATION OF JACK ON CEILING TO HELP WIFI TECHNICIAN LOCATE; DEALER TO PROVIDE LADDER FOR WIFI TECHNICIAN'S USE. 16 ADDITIONAL ELECTRICAL OUTLET AND OR DATA / VOICE. 1/4" = 1'-0" 3' - 4" 2' - 8" 9" 3' - 4" 4D+1T 2" CONDUIT STUB-UP BEHIND FIXTURE (OUTSIDE OF WALL), FLUSH WITH CONCRETE 3/4" CONDUIT FOR POWER * MEP DRAWINGS SHALL GOVERN DUPLEX OUTLET DUPLEX OUTLET DEDICATED QUAD OUTLET 2' - 8" 1" CONDUIT FOR DATA 2" CONDUIT STUB-UP NEXT TO FLOOR BOX B 3' - 9" 3' - 9" OF BCW 2 R1.1 COAXIAL CABLE OUTLET 1' - 8" VOICE OUTLET VOICE / DATA OUTLET 1' - 6" NOTE: IF LEARNING TABLES ARE TO BE TEMPORARILY USED AS POS STATIONS. THE 2" CONDUIT SHOWN IN ENLARGED PLAN IS REQUIRED IN ORDER TO PROVIDE THE HDMI AND USB CORDS AND AMPLIFIER FROM THE BACKWRAP TO THE LEARNING TABLE. THE HDMI, USB, AND AMPLIFIER SHOULD BE ORDERED THROUGH GRAINGER AS REQUIRED. WIREMOLD BRAND 881RC4ATCBK C 2' - 8" DATA OUTLET NOTE: RECEPTACLES @ BACKWRAP AND LEARNING TABLE TO BE ON A SINGLE 20 AMP DEDICATED CIRCUIT. DO NOT ADD OTHER RECEPTACLES TO CIRCUIT. (2D) (2D) FLOOR DATA OUTLET FINISH FLOOR FLOOR DUPLEX OUTLET 2 POWER FLOOR QUAD OUTLET 4 DATA & 1 PHONE, 4 POWER T 3 R1.1 THERMOSTAT ELEVATION @ BCW-MED Y NL O N T EN CTIO T IN RU N T SIG ONS E R D OR C O F TF NO 3/8" = 1'-0" PC REFERENCE PLAN @ BCW-MED TYPICAL OUTLET CONFIGURATION DETAILS 3/8" = 1'-0" AATV (TV WALL): PROVIDE CONDUIT FROM ACCESSIBLE CEILING TO COAX TERMINATIONS. ROUTE COAX CABLING TO MDF ROOM. MWU: C ARCH/ENGR OF RECORD BRUCE A. LOTT DESIGNED BY NIGHT LIGHT NIGHT LIGHT BDR C DRAWN BY KCC (2) DATA FOR DIGITAL LIFE & EVERY OTHER MWU (2) GROUPS OF: (1) COAX AND (2) DATA / QUAD RECEPTACLE + NIGHT LIGHT DUPLEX RECEPTACLE CHECKED BY BAL NONSWITCHED SWITCHED FOR DISPLAY LIGHTING PROJECT NUMBER C06898.035.00 DATE A IP (I-PHONE): BCW (BACKWRAP) AND PTR (PRINTER): 09/26/14 TITLE POWER/DATA/FLOOR BOX PLAN 9/26/2014 3:29:16 PM P:\Cingular\C06898.035.00 - AT&T 2400 PGA, FL DES1\Models\689835_2400 PGA_FL_2013.rvt REVISION OUTLET FOR GRID GRAPHIC LIGHTING, TO BE NIGHT LIGHT NOTE: WIREMOLD RFB4E FLOOR BOX W/ 2 HUB ACCESSORY AND 6CTBKTR COVER CAN BE USED IN PLACE OF THE 881RC4ATCBK IF BOX IS AVAILABLE. IF USED, CONDUIT WOULD TERMINATE AT BOX AND NOT STUB-UP THROUGH FLOOR 1' - 6" 7' - 7" 18" 4D+1T FLOOR TRENCH 2" CONDUIT FOR (1) HDMI, (2) USB POWER / COMMUNICATIONS REFERENCE LEGEND OF BCW 18" 18" BCW-MED 2' - 8" 1' - 8" @ 72" AFF FINAL DESIGN INTENT SET ISSUE X 1 OF SM COMM TBL 5' - 5" These plans are protected by Federal Copyright protection. Unauthorized use may result in an infringement action. 7' - 7" 7 2D WI-FI SYSTEM (EQUIPMENT PROVIDED BY AT&T) REQUIRES A POA (POWER OVER ETHERNET) CONNECTION TO A SINGLE ACCESS POINT, WITH SUCH ACCESS POINT TO BE LOCATED ON THE CEILING NEAR THE MIDDLE OF THE STORE. POA TO EXTEND TO THE WI-FI EQUIPMENT LOCATION IN BOH. Offices in Melbourne, Orlando, West Palm Beach, Atlanta, Charleston, Seattle 9 (2D) 1 6 7' - 10" (2D) 2014 EQ 16 (2D) F4A FOR THE WINDOW BANNERS TO BE ON THE EXTERIOR SIGNAGE CIRCUIT AND TIED TO THE EXTERIOR SIGN TIMECLOCK. K. 24" 3' - 9" OF AATV (4D) 7' - 9 3/4" 2D J. 6 (2D) 1' - 8 3/4" OF SALES FLOOR & BCW 72" (2D) EQ 7 © 2727 Paces Ferry Road | Bldg 1 | Suite 1800 Atlanta | Georgia | 30339 770-933-9242 | 770-933-9246 f D. (2D) 18" Copyright Architects, Engineers, Constructors 5 16 C www.brph.com SE REGION 5' - 5" 2400 PGA BLVD, PALM BEACH GARDENS, FL 33410 9' - 10" 2400 PGA, FL DES 1 3' - 8 1/2" GC TO PROVIDE ALL WIRING IN FULL COMPLIANCE WITH THE MOST CURRENT AT&T IT STANDARDS, RFP V2.5 OR LATER. AT&T MOBILITY 7' - 11 1/2" A. (1) SWITCHED DUPLEX RECEPTACLE FOR INTEGRATED LIGHTING 1 2 3 4 DUPLEX RECEPTACLE / (2) DATA (1) DUPLEX RECEPTACLE FOR PRINTER (1) QUAD RECEPTACLE / (4) DATA / (1) TELEPHONE FOR PRINTER AND ADDITIONAL IT EQUIPMENT 5 DRAWING NO. R1.1 6