CONDUIT AND WIRE IN WALL OR ABOVE CEILING HOME RUN TO PANEL. PROVIDE #12 WIRES IN CONDUIT UON. GROUND WIRE REQUIRED IN PVC CONDUIT. SIZE WIRING AND CONDUIT PER NEC. ELECTRICAL LEGEND ELECTRICAL PANEL LIGHTING PLAN SPECIAL NOTES: CONDUIT AND WIRE RUN UNDERGROUND OR BELOW SLAB. DISCONNECT 1. VERIFY FIXTURE TYPES, LOCATIONS AND MOUNTING HEIGHT WITH OWNER. 20A, 125V DUPLEX RECEPTACLE MOUNTED 18" AFF UON. 2. FIXTURES (EXCEPT INCANDESCENT) TO BE PROVIDED WITH LAMPS BY MANUFACTURER. 20A, 125V, DEDICATED DUPLEX RECEPTACLE MOUNTED 18" AFF UON. 4. CONNECT NIGHT LIGHTS, EXIT SIGNS AND EMERGENCY FIXTURES AHEAD OF ANY SWITCHING OR CONTROLS. 3. VERIFY EXISTING CONDITIONS AND MODIFY OR PROVIDE NEW EQUIPMENT AS NECESSARY. 5. VERIFY EXISTING CONDITIONS PRIOR TO ROUGH-IN. REWIRE LIGHT FIXTURES PER PLAN. MODIFY EXISTING FIXTURES AS REQUIRED TO BE IN GOOD WORKING ORDER AT TURN-OVER. PROVIDE NEW LAMPS AND ACCESSORIES AS REQUIRED. 4. MODIFY PANEL BREAKERS AS NECESSARY. INSTALLATION SHALL MEET ALL REQUIREMENTS OF NATIONAL FIRE SAFETY CODES AND LOCAL CODES. 6. VERIFY WITH OWNER LOCATION OF LIGHT SWITCHES PRIOR TO ROUGH-IN. COORDINATE ANY RELOCATING AND CONTROL SCHEME CHANGES AS REQUIRED BY OWNER. 3460 LOCKMED Dr. NORCROSS, GA 30092 Tel: 770.355.7423 Fax: 770.242.0257 email: louis@theystudio.com WEATHER PROOF 20A, 125V, GFI DUPLEX RECEPTACLE EXIT/EMERGENCY LIGHT UNIT W/ BATTERY BACKUP 20A, 125V DUPLEX RECEPTACLE CEILING MOUNTED UON. LIGHT SWITCH, 1-POLE, 20A, 120/277V, 48"AFF UON. 15A, 125V GFCI DUPLEX RECEPTACLE CEILING MOUNTED UON. ELECTRICAL JUNCTION BOX WITH COVER PLATE MULTY-POLE SPECIAL TYPE RECEPTACLE. VERIFY WITH EQUIPMENT MANUFACTURER SPECIFICATIONS. MOUNT 40" AFF OR AS SPECIFIED BY MANUFACTURER. TIME SWITCH MOUNTED NEAR ELECTRICAL PANEL. TORK MODEL #ES101 OR EQUAL. SET ON/OFF TIME AS DIRECTED BY OWNER. UNLESS OTHERWISE NOTED SURFACE/CEILING MOUNTED LIGHT FIXTURE WEATHER PROOF PENDENT LIGHTING ELECTRIC WATER COOLER ABOVE FINISHED FLOOR CEILING FAN TELEPHONE/DATA OUTLET 1'-6" AFF WITH 3/4" CONDUIT TO TELEPHONE BACKBOARD UON. EMERGENCY LIGHT UNIT W/ BATTERY BACKUP H H LIGHT FIXTURE SCHEDULE 5382-D BUFORD HWY, DORAVILLE, GA. 30340 2. EQUIPMENT WITH MAXIMUM OVERCURRENT PROTECTION RATING SHALL BE INSTALLED WITHIN SUCH RATING. 3. VERIFY CEILING TYPES AND PROVIDE MOUNTING CLIPS AND ACCESSORIES AS REQUIRED. Y STUDIO, LLC 2X4 FLUORESCENT LIGHT FIXTURE GONG CHA 1. CONTRACTOR SHALL VERIFY EXACT REQUIREMENTS AND PROPER INSTALLATION OF ALL ELECTRICAL EQUIPMENT AND FIXTURES PRIOR TO ROUGH-IN. 20A, 125V, GFCI DUPLEX RECEPTACLE MOUNTED 18" AFF UON. INTERIOR RENOVATION POWER PLAN SPECIAL NOTES: CONDUIT AND WIRE RUN EXPOSED. SEAL: I S T E R RE ED G NO.PE040537 N G I N E E N Y U A E SCALE: 1/4"=1'-0" R E Z H PROPOSED LIGHTING PLAN O PROFESSIONAL C FOR: NOT FOR CONSTRUCTION RELEASED FOR CONSTRUCTION DRAWN BY: L. YUAN REVIEWED BY: L. YUAN SHEET TITLE: ELECTRICAL PLANS DATE: 02.18.2019 PROJECT NUMBER: SHEET NUMBER E-1 PROPOSED POWER PLAN SCALE: 1/4"=1'-0" Y STUDIO, LLC COPYRIGHT 2018