NRL 0280/0700 heat pump Air-cooled heat pumps Axial fans Cooling capacity from 51 kW to 149 kW Heating capacity from 58 kW to 172 kW R410A Aermec participate in the EUROVENT program:LCP/A/P/C the products are present on the site www.eurovent-certification.com • • • • COMPACT VERSION LOW NOISE COMPACT VERSION HIGH EFFICIENCY VERSION LOW NOISE HIGH EFFICIENCY VERSION - 2 REFRIGERANT CIRCUITS - PUMP ASSEMBLY OPTION - PUMP ASSEMBLY AND BUFFER TANK OPTION Characteristics • • • • • • • • • Available in 9 sizes Refrigerant R410A 2 refrigerant circuits High efficiency even at part load Heat exchangers optimised to benefit from the excellent heat transfer characteristics of R410A High efficiency scroll compressors Axial fans with low sound level Solid construction with polyester anti-corrosion painted finish Operating Limits: Heating mode Versions H/HL - Max. water produced 50°C - Max. external air temperature 30°C (42°C with accessory DCPX) Versions HA/HE - Max. water produced 55°C - Max. external air temperature 30°C (42°C with accessory DCPX) Cooling mode Versions H/HL - Max. water produced 18°C - Max. external air temperature 30°C 42°C Versions HA/HE - Max. water produced 18°C - Max. external air temperature 46°C • Versions available: H Standard compact heat pump HL Low noise compact heat pump HA High efficiency heat pump HE High efficiency low noise heat pump • Fan type (selected in unit configurator): - “°” Standard - “J” Inverter • Pump assembly and buffer tank options complete with water filter, flow switch, expansion tank, charging point, and antifreeze electric heater • Microprocessor control system: - Control from the entering water tempera- ture, with the possibility of selecting control of the leaving water temperature. - Condensing control in summer with a 0-10 V modulating signal based on pressure and compensated for external air temperature (with DCPX accessory) - Evaporating control in summer for heat pump operation (with DCPX accessory) - Intelligent defrost control on drop of pressure - Automatic rotation of compressors and pumps based on operating hours - Load limiting safety control - Low and high pressure transducers (standard for all units) - Automatic reset of alarms before tripping - Display in 4 languages - Alarm history Accessories • AERSET: The AERSET accessory allows the automatic compensation of the operating setpoint of the unit to which it is connected, based on a 0-10V MODBUS input signal. Mandatory accessory: AER485 or MODU485A • AER485: RS-485 interface for supervision systems with MODBUS protocol. • VT: set of four anti-vibration mounts, to be fitted below the unit base. • DCPX: Low ambient device for cooling operation below 10 °C down to -10 °C. Pressure transducers read the condensing pressure and the electronic controller varies fan speed to maintain adequate pressure for correct unit operation. It also allows a correct operation by heating with external temperatures above 30 ° C and up to 42 ° C. • DRE: Soft starter (current reduction of about 30% for single circuit units, 26% for two circuit units, 22% for three circuit units). Only available for 400V-3-phase power supply. Factory fitted only. • GP: Protection grille protects the external coil from accidental damage. • PGS: Daily/Weekly Programmer. Allows two daily time-clock programmes (two switch on/ off cycles) and different programmes for each day of the week. • RIF: Power factor correction. Connected in parallel to the motor allowing about 10% reduction of input current. Must be requested at time of order and is available factory fitted only. • AERWEB300: Accessory AERWEB allows remote control of a chiller through a common PC and an ethernet connection over a common browser; 4 versions available: AERWEB300-6: Web server to monitor and remote control max. 6 units in RS485 network; AERWEB300-18: Web server to monitor and remote control max. 18 units in RS485 network; AERWEB300-6G: Web server to monitor and remote control max. 6 units in RS485 network with integrated GPRS modem; AERWEB300-18G: Web server to monitor and remote control max. 18 units in RS485 network with integrated GPRS modem; • DUALCHILLER: Simplified control system to switch on/off and control two chillers in a single system (using Aermec GR3 command), as if they were a single unit. • MULTICHILLER: Control system for multiple parallel installed constant flow chillers providing individual chiller on/off and control capability. • TRX1: Metal cap that replaces the plastic cap, mounted as shipping protection, for immersion heater holes in the buffer tank. • PRM1: FACTORY FITTED ACCESSORY. A manual reset pressure switch wired in series with the existing high pressure switch installed on the compressor discharge line. • TP3: As standard COMPATIBILITY with the VMF SYSTEM For more information on the system refer to the manual. Mod. NRL AERSET AER485 DUALCHILLER MULTICHILLER PGS AERWEB300 TRX1 VT (00-P1-P2-P3-P4) VT (01-02-03-04-0506-07-08-09-10) DCPX DCPX vers. with high static pressure fans (*) DRE GP RIF PRM1 Vers. All All All All All All All H HL HA HE H HL HA HE H HL HA HE H HL HA HE All H HL HA HE All All 0280 • • • • • • • 17 17 13 13 58 58 63 63 281 3 3 50 • Accessory compatibility 0300 0330 0350 • • • • • • • • • • • • • • • • • • • • • 17 17 17 17 17 17 13 13 13 13 13 13 58 58 58 58 59 59 63 63 63 63 63 63 301 331 351 3 3 3 4 4 4 50 50 51 • • • 0500 • • • • • • • 13 13 13 13 10 10 10 10 64 standard 64 standard 501 2 (x2) 2 (x2) 2 (x2) 2 (x2) 52 • 0550 • • • • • • • 13 13 13 13 10 10 10 10 64 standard 64 standard 551 2 (x2) 2 (x2) 2 (x2) 2 (x2) 52 • 0600 • • • • • • • 13 13 13 13 10 10 10 10 64 standard 64 standard 601 2 (x2) 2 (x2) 2 (x2) 2 (x2) 53 • 0650 • • • • • • • 13 13 13 13 10 10 10 10 64 standard 64 standard 651 2 (x2) 2 (x2) 2 (x2) 2 (x2) 53 • 0700 • • • • • • • 13 13 22 22 10 10 22 22 64 standard 65 standard 701 2 (x2) 2 (x2) 2 (x3) 2 (x3) 53 • (*) DCPX not necessary for units with high static pressure fans (sizes 500 to 700). Fans are already fitted with speed controller. Unit Configurator By suitably combining the numerous options available it is possible to configure each model in such a way as to meet even the most demanding of system requirements. Configuration fields: 123 | Code 4567 8 9 10 11 | | | | | | | Model | Version | | | Size Expansion valve Heat recovery Code: NRL Size: 0280, 0300, 0330, 0350, 0500, 0550, 0600, 0650, 0700 Expansion valve: ° - Standard thermostatic expansion valve for water temperature down to +4 °C X - Electronic thermostatic valve, max. temp. of water produced: +4°C ( for lower temperatures please contact us) Model: H - Heat pump Heat recovery ° - Without heat recovery D - With partial heat recovery (desuperheater) T - With total heat recovery) Version: ° - Standard compact L - Compact low noise A - High efficiency E - High efficiency low noise Coil: ° - Aluminium R - Copper S - Tinned copper V - Coated aluminium 12 | | | Coil 13 | Fan 14 | | | Power supply 15 16 | Hydronic Kit Fan: ° - Standard M - High static pressure (sizes 280-350) J - Inverter (sizes 500-700) Power supply: ° - 400V 3N~ 50Hz with circuit breakers 1 - 220V 3~ 50Hz with circuit breakers Integrated hydronic module: 00 - without pump or buffer tank 01 - single low head pump and buffer tank 02 - single and standby low head pump and buffer tank 03 - single high head pump and buffer tank 04 - single and standby high head pump and buffer tank 05 - single low head pump and buffer tank (with holes for immersion heaters) 06 - single and standby low head pump and buffer tank (with holes for immersion heaters) 07 - single high head pump and buffer tank (with holes for immersion heaters) 08 - single and standby high head pump and buffer tank (with holes for immersion heaters) 09 - double hydraulic circuit 10 - double hydraulic circuit with immersion heater P1 - single low head pump without buffer tank P2 - single and standby low head pump without buffer tank P3 - single high head pump without buffer tank P4 - single and standby high head pump without buffer tank Attention: – the standard options are shown by the symbol ° – the configurations XD and XT are not available (only for liquid temperatures below +4°C ) Technical Data Mod. NRL U.M. Cooling capacity (kW) Total power input (kW) Water flow rate (l/h) Total pressure drop (kPa) Heating capacity (kW) Total power input (kW) Water flow rate (l/h) Total pressure drop (kPa) Vers. H HL HA HE H HL HA HE H HL HA HE H HL HA HE H HL HA HE H HL HA HE H HL HA HE H HL HA HE 0280 51 53 20,45 18,10 8772 9116 47 20 58 59 19,06 17,55 9976 10148 61 25 0300 61 62 22,87 20,27 10492 10664 43 27 68 69 21,77 20,64 11696 11868 54 34 0330 66 69 26,64 23,27 11352 11868 51 23 76 76 24,87 22,82 12900 13072 66 28 0350 73 77 31,44 26,92 12556 13244 45 27 83 86 28,35 26,20 14104 14792 56 34 0500 89 83 94 90 36,91 40,13 30,82 33,48 15480 14276 16168 15480 46 39 33 30 98 100 104 104 33,81 33,81 31,71 31,71 16684 17028 17716 17716 55 55 40 40 0550 94 89 100 95 41,06 43,40 34,06 36,81 16340 15480 17200 16340 50 45 36 32 104 107 111 111 36,69 36,70 34,37 34,37 17716 18232 18920 18920 62 62 44 44 0600 114 109 121 114 49,76 52,41 41,53 45,46 19780 18920 20984 19608 53 49 36 31 127 130 136 136 43,93 43,94 40,75 40,75 21672 22188 23220 23220 67 67 44 44 0650 133 123 137 127 54,08 58,97 48,45 53,26 23048 21328 23736 22016 58 50 43 37 138 151 153 153 48,93 48,98 45,69 45,69 23564 25800 26144 26144 73 73 52 52 0700 144 139 149 142 63,78 66,43 52,05 58,49 24940 24080 25800 24596 64 60 49 45 157 166 172 172 56,22 56,28 53,08 53,08 26832 28380 29412 29412 83 83 64 64 H HL HA HE H HL HA HE H HL HA HE 2,48 2,92 3,02 3,85 3,07 3,38 2,65 3,04 3,23 3,77 3,15 3,36 2,46 2,95 3,02 3,85 3,04 3,34 2,31 2,85 3,31 3,73 2,91 3,30 2,42 2,06 3,04 2,68 3,30 3,28 3,71 3,67 2,89 2,95 3,26 3,26 2,30 2,06 2,92 2,57 3,19 3,18 3,48 3,45 2,83 2,91 3,22 3,22 2,30 2,09 2,92 2,50 3,69 3,66 4,13 4,03 2,89 2,95 3,33 3,33 2,46 2,09 2,83 2,39 3,42 3,42 4,09 3,99 2,82 3,08 3,34 3,34 2,26 2,10 2,87 2,43 3,50 3,48 3,98 3,87 2,79 2,95 3,24 3,24 36 30 33 35 46 155 40 34 38 39 53 184 88 99 77 89 100 111 90 97 2/2 2/2 14000 20000 14000 20000 4 6 20000 26000 20000 26000 6 8 2”1/2 2”1/2 ENEGY INDEX EER (W/W) ESEER (W/W) COP (W/W) POWER SUPPLY Power supply Total input current cooling mode (A) Total input current heating mode (A) Maximum current (FLA) Starting current (LRA) Compressor type Compressor / circuit Fan type (A) (A) n°/n° Air flow (cooling) (m³/h) Air flow (heating) (m³/h) Fan quantity (n°) Evaporator Hydraulic connection Hydraulic connection dimension (Ø) DATA DECLARED IN ACCORDANCE WITH UNI EN 14511: 2011 All H HL HA HE H HL HA HE All All All All All H HL HA HE H HL HA HE H HL HA HE All All All COOLING Evaporator water inlet Evaporator water outlet External air temperature t 400V 3N~ 50Hz with thermomagnetic switches 63 67 81 44 51 70 75 90 55 60 71 37 45 60 64 78 60 63 76 41 50 55 59 72 43 49 60 64 79 58 63 76 81 100 190 200 214 220 232 Scroll 2/2 2/2 3/2 3/2 4/2 Axial 39400 39400 39400 20000 20000 28400 28700 28700 37000 37000 36500 26000 26000 20200 21100 21400 39400 39400 39400 20000 20000 39400 39400 39400 37000 37000 36500 26000 26000 37000 37000 36500 2 2 2 6 6 2 2 2 2 2 2 8 8 2 2 2 Plates Victaulic 2”1/2 2”1/2 2”1/2 2”1/2 2”1/2 12°C 7°C 35 °C 5°C HEATING: Evaporator water inlet External air temperature Evaporator water outlet t 82 95 82 91 112 243 88 99 122 261 4/2 4/2 37500 27400 36500 22400 37500 37500 36500 36500 2 2 2 2 37500 28100 58000 31900 37500 37500 58000 58000 2 2 3 3 2”1/2 2”1/2 40°C 7°C B.S. / 6°C B.U. 45°C 5°C Mod. NRL HYDRONIC KIT Useful head low pump cooling mode U.M. (kPa) Useful head high pump cooling mode (kPa) Useful head low pump heating mode (kPa) Useful head high pump heating mode Buffer tank capacity SOUND DATA (kPa) (l) Sound power dB(A) Sound pressure dB(A) Vers. 0280 0300 0330 0350 0500 0550 0600 0650 0700 H HL HA HE H HL HA HE H HL HA HE H HL HA HE All 105 104 147 143 102 94 142 133 300 107 108 152 147 104 98 143 137 300 97 94 144 133 93 83 132 123 300 93 97 144 136 88 84 128 124 300 127 131 128 135 191 191 167 173 123 122 117 117 162 160 156 156 500 116 120 117 126 183 183 155 164 111 109 114 102 150 148 153 142 500 100 104 98 113 234 234 192 205 91 88 91 79 184 182 185 173 500 86 95 81 99 236 236 176 193 83 69 71 59 177 165 167 155 500 103 108 103 117 223 223 158 171 91 80 63 63 146 136 122 122 500 H HL HA HE H HL HA HE 73 74 41 42 74 75 42 43 74 75 42 43 75 76 43 44 82 77 82 74 50 45 50 42 82 77 82 74 50 45 50 42 82 77 82 74 50 45 50 42 83 78 83 75 51 46 51 43 83 78 85 77 51 46 53 45 SOUND POWER Aermec determines sound power values on the basis of measurements made in accordance with UNI EN ISO 9614-2, as required for Eurovent certification. SOUND PRESSURE Sound pressure in free field, at 10 m distance from the external surface of the unit (in accordance with UNI EN ISO 3744). Dimensions (mm) NRL 0350 H/HL NRL 0280-0300-0330 H/HL NRL 0500-0550-0600-0650-0700 H/HL A A A C C C B B B NRL 0280 HA/HE NRL 0300-0330-0350 HA/HE NRL 0500-0550-0600-0650 HA/HE NRL 0700 HA/HE A A A C C C B Mod. NRL Height A Width B U.M. (mm) (mm) Length C (mm) Weight empty C B B kg Vers. All All H - HL HA - HE H - HL HA - HE 0280 1606 1100 2450 2450 713 730 0300 1606 1100 2450 2950 724 795 0330 1606 1100 2450 2950 731 805 0350 1606 1100 2450 2950 740 811 0500 1875 1100 3010 3010 913 1099 Note: Sizes 280,300,330,350 are only available in versions HL - HE. Aermec reserves the right to make all modification deemed necessary for improving the product at any time with any modification of technical data. Aermec S.p.A. Via Roma, 996 - 37040 Bevilacqua (VR) - Italy Tel 0442633111 - Fax 044293730 www.aermec.com B 0550 1875 1100 3010 3010 917 1103 0600 1875 1100 3010 3010 1016 1204 0650 1875 1100 3010 3010 1130 1212 0700 1875 1100 3010 3950 1142 1390 Cod.: SNRLHUY.08 / 1305 A