NRL
0280/0700
heat pump
Air-cooled heat pumps
Axial fans
Cooling capacity from 51 kW to 149 kW
Heating capacity from 58 kW to 172 kW
R410A
Aermec
participate in the EUROVENT
program:LCP/A/P/C
the products are present on the site
www.eurovent-certification.com
•
•
•
•
COMPACT VERSION
LOW NOISE COMPACT VERSION
HIGH EFFICIENCY VERSION
LOW NOISE HIGH EFFICIENCY
VERSION
- 2 REFRIGERANT CIRCUITS
- PUMP ASSEMBLY OPTION
- PUMP ASSEMBLY AND BUFFER
TANK OPTION
Characteristics
•
•
•
•
•
•
•
•
•
Available in 9 sizes
Refrigerant R410A
2 refrigerant circuits
High efficiency even at part load
Heat exchangers optimised to benefit from the
excellent heat transfer characteristics of R410A
High efficiency scroll compressors
Axial fans with low sound level
Solid construction with polyester anti-corrosion painted finish
Operating Limits:
Heating mode
Versions H/HL
- Max. water produced 50°C
- Max. external air temperature 30°C
(42°C with accessory DCPX)
Versions HA/HE
- Max. water produced 55°C
- Max. external air temperature 30°C
(42°C with accessory DCPX)
Cooling mode
Versions H/HL
- Max. water produced 18°C
- Max. external air temperature 30°C 42°C
Versions HA/HE
- Max. water produced 18°C
- Max. external air temperature 46°C
• Versions available:
H Standard compact heat pump
HL Low noise compact heat pump
HA High efficiency heat pump
HE High efficiency low noise heat pump
• Fan type (selected in unit configurator):
- “°” Standard
- “J” Inverter
• Pump assembly and buffer tank options
complete with water filter, flow switch,
expansion tank, charging point, and antifreeze electric heater
• Microprocessor control system:
- Control from the entering water tempera-
ture, with the possibility of selecting control of the leaving water temperature.
- Condensing control in summer with a 0-10
V modulating signal based on pressure and
compensated for external air temperature
(with DCPX accessory)
- Evaporating control in summer for heat
pump operation (with DCPX accessory)
- Intelligent defrost control on drop of pressure
- Automatic rotation of compressors and
pumps based on operating hours
- Load limiting safety control
- Low and high pressure transducers (standard for all units)
- Automatic reset of alarms before tripping
- Display in 4 languages
- Alarm history
Accessories
• AERSET: The AERSET accessory allows the
automatic compensation of the operating setpoint of the unit to which it is connected,
based on a 0-10V MODBUS input signal.
Mandatory accessory: AER485 or MODU485A
• AER485: RS-485 interface for supervision systems with MODBUS protocol.
• VT: set of four anti-vibration mounts, to be fitted below the unit base.
• DCPX: Low ambient device for cooling operation below 10 °C down to -10 °C. Pressure
transducers read the condensing pressure and
the electronic controller varies fan speed to
maintain adequate pressure for correct unit
operation. It also allows a correct operation
by heating with external temperatures above
30 ° C and up to 42 ° C.
• DRE: Soft starter (current reduction of about
30% for single circuit units, 26% for two circuit units, 22% for three circuit units). Only
available for 400V-3-phase power supply.
Factory fitted only.
• GP: Protection grille protects the external coil
from accidental damage.
• PGS: Daily/Weekly Programmer. Allows two
daily time-clock programmes (two switch on/
off cycles) and different programmes for each
day of the week.
• RIF: Power factor correction. Connected in parallel
to the motor allowing about 10% reduction of
input current. Must be requested at time of order
and is available factory fitted only.
• AERWEB300: Accessory AERWEB allows remote
control of a chiller through a common PC and an
ethernet connection over a common browser; 4
versions available:
AERWEB300-6: Web server to monitor and remote
control max. 6 units in RS485 network;
AERWEB300-18: Web server to monitor and remote
control max. 18 units in RS485 network;
AERWEB300-6G: Web server to monitor and remote control max. 6 units in RS485 network with
integrated GPRS modem;
AERWEB300-18G: Web server to monitor and
remote control max. 18 units in RS485 network
with integrated GPRS modem;
• DUALCHILLER: Simplified control system to
switch on/off and control two chillers in a single system (using Aermec GR3 command), as
if they were a single unit.
• MULTICHILLER: Control system for multiple
parallel installed constant flow chillers providing individual chiller on/off and control
capability.
• TRX1: Metal cap that replaces the plastic cap,
mounted as shipping protection, for immersion heater holes in the buffer tank.
• PRM1: FACTORY FITTED ACCESSORY. A
manual reset pressure switch wired in series
with the existing high pressure switch
installed on the compressor discharge line.
• TP3: As standard
COMPATIBILITY with the VMF SYSTEM For
more information on the system refer to the
manual.
Mod. NRL
AERSET
AER485
DUALCHILLER
MULTICHILLER
PGS
AERWEB300
TRX1
VT (00-P1-P2-P3-P4)
VT (01-02-03-04-0506-07-08-09-10)
DCPX
DCPX vers. with high static pressure fans (*)
DRE
GP
RIF
PRM1
Vers.
All
All
All
All
All
All
All
H
HL
HA
HE
H
HL
HA
HE
H
HL
HA
HE
H
HL
HA
HE
All
H
HL
HA
HE
All
All
0280
•
•
•
•
•
•
•
17
17
13
13
58
58
63
63
281
3
3
50
•
Accessory compatibility
0300
0330
0350
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
17
17
17
17
17
17
13
13
13
13
13
13
58
58
58
58
59
59
63
63
63
63
63
63
301
331
351
3
3
3
4
4
4
50
50
51
•
•
•
0500
•
•
•
•
•
•
•
13
13
13
13
10
10
10
10
64
standard
64
standard
501
2 (x2)
2 (x2)
2 (x2)
2 (x2)
52
•
0550
•
•
•
•
•
•
•
13
13
13
13
10
10
10
10
64
standard
64
standard
551
2 (x2)
2 (x2)
2 (x2)
2 (x2)
52
•
0600
•
•
•
•
•
•
•
13
13
13
13
10
10
10
10
64
standard
64
standard
601
2 (x2)
2 (x2)
2 (x2)
2 (x2)
53
•
0650
•
•
•
•
•
•
•
13
13
13
13
10
10
10
10
64
standard
64
standard
651
2 (x2)
2 (x2)
2 (x2)
2 (x2)
53
•
0700
•
•
•
•
•
•
•
13
13
22
22
10
10
22
22
64
standard
65
standard
701
2 (x2)
2 (x2)
2 (x3)
2 (x3)
53
•
(*) DCPX not necessary for units with high static pressure fans (sizes 500 to 700). Fans are already fitted with speed controller.
Unit Configurator
By suitably combining the numerous options available it is possible to configure each model in such a way as to meet even the most demanding of system
requirements.
Configuration fields:
123
|
Code
4567
8
9
10
11
|
|
|
|
|
|
|
Model
|
Version
|
|
|
Size Expansion valve
Heat recovery
Code:
NRL
Size:
0280, 0300, 0330, 0350, 0500, 0550, 0600, 0650, 0700
Expansion valve:
° - Standard thermostatic expansion valve for water temperature
down to +4 °C
X - Electronic thermostatic valve, max. temp. of water produced: +4°C
( for lower temperatures please contact us)
Model:
H - Heat pump
Heat recovery
° - Without heat recovery
D - With partial heat recovery (desuperheater)
T - With total heat recovery)
Version:
° - Standard compact
L - Compact low noise
A - High efficiency
E - High efficiency low noise
Coil:
° - Aluminium
R - Copper
S - Tinned copper
V - Coated aluminium
12
|
|
|
Coil
13
|
Fan
14
|
|
|
Power supply
15 16
|
Hydronic
Kit
Fan:
° - Standard
M - High static pressure (sizes 280-350)
J - Inverter (sizes 500-700)
Power supply:
° - 400V 3N~ 50Hz with circuit breakers
1 - 220V 3~ 50Hz with circuit breakers
Integrated hydronic module:
00 - without pump or buffer tank
01 - single low head pump and buffer tank
02 - single and standby low head pump and buffer tank
03 - single high head pump and buffer tank
04 - single and standby high head pump and buffer tank
05 - single low head pump and buffer tank (with holes for immersion heaters)
06 - single and standby low head pump and buffer tank (with holes
for immersion heaters)
07 - single high head pump and buffer tank (with holes for immersion heaters)
08 - single and standby high head pump and buffer tank (with holes
for immersion heaters)
09 - double hydraulic circuit
10 - double hydraulic circuit with immersion heater
P1 - single low head pump without buffer tank
P2 - single and standby low head pump without buffer tank
P3 - single high head pump without buffer tank
P4 - single and standby high head pump without buffer tank
Attention:
– the standard options are shown by the symbol °
– the configurations XD and XT are not available (only for liquid temperatures below +4°C )
Technical Data
Mod. NRL
U.M.
Cooling capacity
(kW)
Total power input
(kW)
Water flow rate
(l/h)
Total pressure drop
(kPa)
Heating capacity
(kW)
Total power input
(kW)
Water flow rate
(l/h)
Total pressure drop
(kPa)
Vers.
H
HL
HA
HE
H
HL
HA
HE
H
HL
HA
HE
H
HL
HA
HE
H
HL
HA
HE
H
HL
HA
HE
H
HL
HA
HE
H
HL
HA
HE
0280
51
53
20,45
18,10
8772
9116
47
20
58
59
19,06
17,55
9976
10148
61
25
0300
61
62
22,87
20,27
10492
10664
43
27
68
69
21,77
20,64
11696
11868
54
34
0330
66
69
26,64
23,27
11352
11868
51
23
76
76
24,87
22,82
12900
13072
66
28
0350
73
77
31,44
26,92
12556
13244
45
27
83
86
28,35
26,20
14104
14792
56
34
0500
89
83
94
90
36,91
40,13
30,82
33,48
15480
14276
16168
15480
46
39
33
30
98
100
104
104
33,81
33,81
31,71
31,71
16684
17028
17716
17716
55
55
40
40
0550
94
89
100
95
41,06
43,40
34,06
36,81
16340
15480
17200
16340
50
45
36
32
104
107
111
111
36,69
36,70
34,37
34,37
17716
18232
18920
18920
62
62
44
44
0600
114
109
121
114
49,76
52,41
41,53
45,46
19780
18920
20984
19608
53
49
36
31
127
130
136
136
43,93
43,94
40,75
40,75
21672
22188
23220
23220
67
67
44
44
0650
133
123
137
127
54,08
58,97
48,45
53,26
23048
21328
23736
22016
58
50
43
37
138
151
153
153
48,93
48,98
45,69
45,69
23564
25800
26144
26144
73
73
52
52
0700
144
139
149
142
63,78
66,43
52,05
58,49
24940
24080
25800
24596
64
60
49
45
157
166
172
172
56,22
56,28
53,08
53,08
26832
28380
29412
29412
83
83
64
64
H
HL
HA
HE
H
HL
HA
HE
H
HL
HA
HE
2,48
2,92
3,02
3,85
3,07
3,38
2,65
3,04
3,23
3,77
3,15
3,36
2,46
2,95
3,02
3,85
3,04
3,34
2,31
2,85
3,31
3,73
2,91
3,30
2,42
2,06
3,04
2,68
3,30
3,28
3,71
3,67
2,89
2,95
3,26
3,26
2,30
2,06
2,92
2,57
3,19
3,18
3,48
3,45
2,83
2,91
3,22
3,22
2,30
2,09
2,92
2,50
3,69
3,66
4,13
4,03
2,89
2,95
3,33
3,33
2,46
2,09
2,83
2,39
3,42
3,42
4,09
3,99
2,82
3,08
3,34
3,34
2,26
2,10
2,87
2,43
3,50
3,48
3,98
3,87
2,79
2,95
3,24
3,24
36
30
33
35
46
155
40
34
38
39
53
184
88
99
77
89
100
111
90
97
2/2
2/2
14000
20000
14000
20000
4
6
20000
26000
20000
26000
6
8
2”1/2
2”1/2
ENEGY INDEX
EER
(W/W)
ESEER
(W/W)
COP
(W/W)
POWER SUPPLY
Power supply
Total input current
cooling mode
(A)
Total input current
heating mode
(A)
Maximum current (FLA)
Starting current (LRA)
Compressor type
Compressor / circuit
Fan type
(A)
(A)
n°/n°
Air flow
(cooling)
(m³/h)
Air flow
(heating)
(m³/h)
Fan quantity
(n°)
Evaporator
Hydraulic connection
Hydraulic connection dimension
(Ø)
DATA DECLARED IN ACCORDANCE WITH
UNI EN 14511: 2011
All
H
HL
HA
HE
H
HL
HA
HE
All
All
All
All
All
H
HL
HA
HE
H
HL
HA
HE
H
HL
HA
HE
All
All
All
COOLING
Evaporator water inlet
Evaporator water outlet
External air temperature
t
400V 3N~ 50Hz with thermomagnetic switches
63
67
81
44
51
70
75
90
55
60
71
37
45
60
64
78
60
63
76
41
50
55
59
72
43
49
60
64
79
58
63
76
81
100
190
200
214
220
232
Scroll
2/2
2/2
3/2
3/2
4/2
Axial
39400
39400
39400
20000
20000
28400
28700
28700
37000
37000
36500
26000
26000
20200
21100
21400
39400
39400
39400
20000
20000
39400
39400
39400
37000
37000
36500
26000
26000
37000
37000
36500
2
2
2
6
6
2
2
2
2
2
2
8
8
2
2
2
Plates
Victaulic
2”1/2
2”1/2
2”1/2
2”1/2
2”1/2
12°C
7°C
35 °C
5°C
HEATING:
Evaporator water inlet
External air temperature
Evaporator water outlet
t
82
95
82
91
112
243
88
99
122
261
4/2
4/2
37500
27400
36500
22400
37500
37500
36500
36500
2
2
2
2
37500
28100
58000
31900
37500
37500
58000
58000
2
2
3
3
2”1/2
2”1/2
40°C
7°C B.S. / 6°C B.U.
45°C
5°C
Mod. NRL
HYDRONIC KIT
Useful head
low pump
cooling mode
U.M.
(kPa)
Useful head
high pump
cooling mode
(kPa)
Useful head
low pump
heating mode
(kPa)
Useful head
high pump
heating mode
Buffer tank capacity
SOUND DATA
(kPa)
(l)
Sound power
dB(A)
Sound pressure
dB(A)
Vers.
0280
0300
0330
0350
0500
0550
0600
0650
0700
H
HL
HA
HE
H
HL
HA
HE
H
HL
HA
HE
H
HL
HA
HE
All
105
104
147
143
102
94
142
133
300
107
108
152
147
104
98
143
137
300
97
94
144
133
93
83
132
123
300
93
97
144
136
88
84
128
124
300
127
131
128
135
191
191
167
173
123
122
117
117
162
160
156
156
500
116
120
117
126
183
183
155
164
111
109
114
102
150
148
153
142
500
100
104
98
113
234
234
192
205
91
88
91
79
184
182
185
173
500
86
95
81
99
236
236
176
193
83
69
71
59
177
165
167
155
500
103
108
103
117
223
223
158
171
91
80
63
63
146
136
122
122
500
H
HL
HA
HE
H
HL
HA
HE
73
74
41
42
74
75
42
43
74
75
42
43
75
76
43
44
82
77
82
74
50
45
50
42
82
77
82
74
50
45
50
42
82
77
82
74
50
45
50
42
83
78
83
75
51
46
51
43
83
78
85
77
51
46
53
45
SOUND POWER
Aermec determines sound power values on
the basis of measurements made in accordance with UNI EN ISO 9614-2, as required
for Eurovent certification.
SOUND PRESSURE
Sound pressure in free field, at 10 m distance
from the external surface of the unit (in accordance with UNI EN ISO 3744).
Dimensions (mm)
NRL 0350 H/HL
NRL 0280-0300-0330 H/HL
NRL 0500-0550-0600-0650-0700 H/HL
A
A
A
C
C
C
B
B
B
NRL 0280 HA/HE
NRL 0300-0330-0350 HA/HE
NRL 0500-0550-0600-0650 HA/HE
NRL 0700 HA/HE
A
A
A
C
C
C
B
Mod. NRL
Height A
Width B
U.M.
(mm)
(mm)
Length C
(mm)
Weight empty
C
B
B
kg
Vers.
All
All
H - HL
HA - HE
H - HL
HA - HE
0280
1606
1100
2450
2450
713
730
0300
1606
1100
2450
2950
724
795
0330
1606
1100
2450
2950
731
805
0350
1606
1100
2450
2950
740
811
0500
1875
1100
3010
3010
913
1099
Note:
Sizes 280,300,330,350 are only available in versions HL - HE.
Aermec reserves the right to make all modification deemed
necessary for improving the product at any time with any
modification of technical data.
Aermec S.p.A.
Via Roma, 996 - 37040 Bevilacqua (VR) - Italy
Tel 0442633111 - Fax 044293730
www.aermec.com
B
0550
1875
1100
3010
3010
917
1103
0600
1875
1100
3010
3010
1016
1204
0650
1875
1100
3010
3010
1130
1212
0700
1875
1100
3010
3950
1142
1390
Cod.: SNRLHUY.08 / 1305