2/1/23, 6:32 PM PanelView Plus: Firmware Upgrade Wizard (FUW) Utility ID: QA5310 | Access Levels: TechConnect PanelView Plus: Firmware Upgrade Wizard (FUW) Utility Document ID QA5310 Published Date 08/02/2022 Summary PanelView Plus: Firmware Upgrade Wizard (FUW) Utility Question How do you run the Firmware Upgrade Wizard (FUW) utility for PanelView Plus terminals? How to flash firmware on PanelView Plus? Environment PanelView Plus PanelView Plus CE PanelView Plus Compact PanelView Plus 6 PanelView Plus 6 Compact PanelView Plus 7 Standard PanelView Plus 7 Performance Note: PanelView Plus CE used to be called VersaView CE. Answer To download the latest firmware: 1. Go to the Product Compatibility & Download Center PanelView Plus Firmware Download 2. Unzip the downloaded file 3. Run the .exe, and it will begin the installation 4. Accept the default installation locations https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/25776/loc/en_US 1/4 2/1/23, 6:32 PM PanelView Plus: Firmware Upgrade Wizard (FUW) Utility Firmware Upgrade Wizard (FUW) The Firmware Upgrade Wizard (FUW) allows the PanelView Plus/ PanelView Plus CE terminals to be upgraded or downgraded to whatever version of firmware is available from the .fup files. The .fup files contain the version of FactoryTalk View Machine Edition that will be installed on the terminal The 3.00.05.65 and above .fup files contain an option that allows selected KEPServer drivers to be installed onto the terminal as well KEPServer drivers are not pre-installed on the pre-PanelView Plus 6 terminals and must be installed via the Firmware Upgrade Wizard Only install the required driver(s). Do NOT check all the drivers, as this can create issues The 3.10 and above .fup files will also automatically update the OS of the terminal PanelView Plus 6 and PanelView Plus 7 are NOT firmware compatible with earlier versions of the firmware, this means: A PanelView Plus 6 can only be updated with PanelView Plus 6 firmware (firmware revisions 5.10.XX and older do not apply) A PanelView Plus 7 can only be updated with PanelView Plus 7 firmware A pre-PanelView Plus 6 cannot be updated with PanelView Plus 6 or PanelView Plus 7 firmware (therefore it cannot run 6.0.XX or higher firmware) If you are upgrading from 3.00 to 3.10 or greater, you will need to order a 2711P-RU310; please contact your distributor to order, see below for details on the Media update kit. For panels at firmware 4.00 or older, a default of the panel's RSLinx Enterprise communications may be necessary to ensure that the Ethernet driver is present Using the Firmware Upgrade Wizard (FUW) 1. Select the Firmware Upgrade Wizard either under the Tools menu in FactoryTalk View Studio or through the Windows Start menu 2. Select the method of upgrade Upgrade firmware on terminal uses RSLinx Enterprise/FactoryTalk Linx to connect to the terminal Create firmware upgrade card allows the user to put the upgrade files onto the root of a USB flash drive or SD/CF card 3. If you choose Create firmware upgrade card, choose the type of terminal you'd like to upgrade, then click Next; if not, go to Step 12 4. The source folder should be selected by default, but it is normally located at: For 32-bit OS: C:\Program Files\Rockwell Software\RSView Enterprise\FUPs\ For 64 bit OS: C:\Program Files (x86)\Rockwell Software\RSView Enterprise\FUPs\ Choose the firmware upgrade version you require, and then click Next If necessary, select the specific KEPServer driver(s) required; if you are not using KEPServer then ensure that no drivers are selected and click Next to continue 5. Verify the data in the screen, and click Finish; a firmware upgrade card will be created 6. Once finished, exit the Firmware Upgrade Wizard and properly eject the removable storage device 7. To prepare the terminal, ensure all the needed .mer files have been backed up https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/25776/loc/en_US 2/4 2/1/23, 6:32 PM PanelView Plus: Firmware Upgrade Wizard (FUW) Utility 8. Insert the upgrade card; you will get a message that tells you which firmware is in the terminal and which is on the memory card 9. You will get Upgrade and Exit buttons; select Upgrade The upgrade will take several minutes; be patient, because if you remove the card before the update is complete you may corrupt the upgrade 10. Once the upgrade completes, you will either get a prompt that the upgrade completed, or you will come back to the Configuration screen; remove the upgrade media at this point On terminals that are being upgraded from below firmware 8.1 to firmware 8.1 or above - or on terminals that do not have desktop access security configured the prompts to set a password and challenge question will appear; it is safe to remove the upgrade media at this point For more information on this procedure, please consult BF22664 - PanelView Plus 6/PanelView Plus 7: prompts for password change after upgrade of firmware. 11. If you are not able to remove the .mer files or prepare the terminal, then power down the terminal, insert the memory card, and reboot. When the display shows 2 Image search while performing the boot tests, it should read the memory card, and install the firmware 12. If you would like to upgrade via Ethernet, you will need to perform Step 2 above, and then you would select Upgrade Firmware on Terminal --> Next 13. Select the Network Connection (Using RSLinx Enterprise/FactoryTalk Linx) radio button and click Next (NEVER USE SERIAL) 14. Select the Terminal that you would like to update (do NOT drill down below the top (IP Address) level), and select Next 15. The top of the window will indicate the current firmware (major.minor.patch.build) of the terminal; select the firmware version you'd like the terminal to be upgraded to from the drop down list and click Next 16. If necessary, select the specific KEPServer driver(s) required; If you are not using KEPServer then ensure none of the drivers are selected and click Next to continue 17. Verify the information on the screen and click Finish to begin the upgrade The Firmware Upgrade Media Kit (2711P-RU310) is shipped with the following: CD containing the Firmware Upgrade Wizard, RSView. Machine Edition v3.10 or later firmware, and the Terminal User Manual. Certificate of Authenticity (COA) label for Microsoft compliance, and assurance of proper repair and reconditioning. End User License Agreement (EULA). These installation instructions. The Advanced Firmware Upgrade Media Kit (2711P-RUA310) is shipped with all of the above plus: 64MB CompactFlash card (2711P-RC1) CompactFlash to PCMCIA Adapter The Firmware Upgrade License Kit (2711P-RULxx) where xx is the number of License, is shipped with the following: Appropriate number of Certificate of Authenticity (COA) labels for Microsoft compliance, and assurance of proper repair and reconditioning. The installation instructions. Note: 6189-RUxx is no longer available, and has been replaced by the 2711P-RUxx for PanelView Plus, and PanelView Plus CE. This catalog number was discontinued 12/31/2015. Also Microsoft Windows CE 4.1 was discontinued on October 2017. https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/25776/loc/en_US 3/4 2/1/23, 6:32 PM PanelView Plus: Firmware Upgrade Wizard (FUW) Utility Recently Viewed RSNetworx assigning incorrect I/O values to 32-point 1794 Flex I/O CompactLogix Controllers: Flashing firmware via EtherNet through ControlFLASH CompactLogix: Unable to flash firmware, device is not in the proper mode DISCLAIMER This knowledge base web site is intended to provide general technical information on a particular subject or subjects and is not an exhaustive treatment of such subjects. Accordingly, the information in this web site is not intended to constitute application, design, software or other professional engineering advice or services. Before making any decision or taking any action, which might affect your equipment, you should consult a qualified professional advisor. ROCKWELL AUTOMATION DOES NOT WARRANT THE COMPLETENESS, TIMELINESS OR ACCURACY OF ANY OF THE DATA CONTAINED IN THIS WEB SITE AND MAY MAKE CHANGES THERETO AT ANY TIME IN ITS SOLE DISCRETION WITHOUT NOTICE. FURTHER, ALL INFORMATION CONVEYED HEREBY IS PROVIDED TO USERS "AS IS." IN NO EVENT SHALL ROCKWELL BE LIABLE FOR ANY DAMAGES OF ANY KIND INCLUDING DIRECT, INDIRECT, INCIDENTAL, CONSEQUENTIAL, LOSS PROFIT OR DAMAGE, EVEN IF ROCKWELL AUTOMATION HAVE BEEN ADVISED ON THE POSSIBILITY OF SUCH DAMAGES. ROCKWELL AUTOMATION DISCLAIMS ALL WARRANTIES WHETHER EXPRESSED OR IMPLIED IN RESPECT OF THE INFORMATION (INCLUDING SOFTWARE) PROVIDED HEREBY, INCLUDING THE IMPLIED WARRANTIES OF FITNESS FOR A PARTICULAR PURPOSE, MERCHANTABILITY, AND NON-INFRINGEMENT. Note that certain jurisdictions do not countenance the exclusion of implied warranties; thus, this disclaimer may not apply to you. www.rockwellautomation.com Copyright © 2023 Rockwell Automation, Inc. All Rights Reserved. https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/25776/loc/en_US 4/4