BUILDING LAWS (30 q&a) 1. What is the 2008 Fire Code of the Philippines? A. RA 9514 B. RA 9154 C. PD 1185 D. RA 1185 2. What is not included in the coverage of the National Building Code? A. Open Market Housing of PD 957 B. Private Buildings C. BP 220 Projects D. Public Buildings 3. A fire is caused by burning paper, cloth, etc. What type of fire is this? 7. It is the road made for walkways across the block with the maximum length of 150 cm. A. Corridor B. Narrow Lane C. Alley D. Collector 8. Eaves over required windows shall not be less than ___ from the side and rear property lines. A. 800mm B. 650mm C. 750mm D. 700mm A. Class B 9. Minimum door width for hospital nursing units? B. Class D A. 1.02 m C. Class A B. 0.91 m D. Class C C. 0.80 m 4. Electrical fire should be suppressed by? A. CO2 Fire Extinguisher B. Water Fire Extinguisher D. 1.12 m 10. As per NBC, what is the maximum height and minimum width of riser and tread? A. 250 / 200 mm C. Foam Fire Extinguisher B. 200 / 200 mm D. Dry Powder Fire Extinguisher C. 200 / 250 mm 5. What is the change in elevation from street level of the dropped curb? D. 180 / 230 mm A. 15 mm 11. What is the best way to provide for the convenience of both people in wheelchair and blind person? B. 20 mm A. Railings C. 25 mm B. Light controlled crossings with pedestrian and audible signals D. 5 mm 6. As per PD 1216 amending open space in residential subdivisions, what is the exclusive allocation (in % of gross area) for parks of medium density subdivisions? A. 9.00 % B. 7.00 % C. 6.00 % D. 3.50 % C. Brightly painted Zebra crossing D. Tactile surfaces /blocks in the immediate vicinity of crossings 12. What is required for fire escape stairs used as a required means of egress only for existing buildings? A. rated at 1 exit unit B. Constitute less than 50% of required exit capacity C. with rated travel capacity of 60 persons per minute D. Constitute more than 50% of required exit capacity BUILDING LAWS (30 q&a) 13. What particular Rule in the 2005 Revised IRR of PD1096 that regulates and determine window openings? A. Section 709 B. Section 808 C. Section 802 D. Section 803 14. As per Fire Code, what is the pipe diameter for the dry standpipe where the highest outlet is 23m or less above fire service connection? B. MWSS C. DPWH D. D. OBO 2. Who do you approach to have the "post" removed? A. Meralco B. DPWH C. MWSS D. OBO A. 102 mm 19. What is the maximum lavatory counter height for disabled? B. 50 mm A. 0.90 m C. 153 mm B. 0.80 m D. 76 mm C. 0.70 m 15. What housing agency coordinates the Community Mortgage Program? A. NHA B. NHMFC C. HIGC D. HLURB 16. What does UHLP stands for? A. Unified Home Lending Program B. Union of Homes and Landowners Projects C. United Home Lease Program D. United Homeowners & Land Program D. 0.60 m 20. Under NBC, every room for habitable use shall be provided with windows with a total free openings equal to at least ___ % of the floor area of the room? A. 20% B. 10% C. 30% D. 50% 21. Given a 1.35m x 2.10m T&B, choose the nearest minimum size for window opening. (in meters) A. 0.40 x 0.60 B. 0.36 x 0.60 17. What housing agency is a quasi government agency? C. 0.60 x 0.60 A. HIGC D. 0.50 x 0.50 B. NHMFC C. HLURB 22. What is the minimum lot area for single detached socialized housing according to BP 220? D. NHA A. 64 sqm 18. A lot has a depth of 30m and a frontage of 15m facing northeast. It has a 20m RROW with 1.5m sidewalk at both sides. The left side of the lot is a school building while at the right is an office mid-rise building. Located in the middle part of the intended facade of your project is a post. The site is still vacant and no water connection yet. 1. Where do you apply for a temporary/permanent water connection? A. Brgy. Chairman B. 48 sqm C. 72 sqm D. 54 sqm 23. Maximum number of rowhouse units in a block? A. 50 B. 25 C. 100 D. 20 BUILDING LAWS (30 q&a) 24. Under BP 220, how much in terms of % of Gross Area is allocated for Community Facilities if there are 150 dwelling Units? A. 1.00% B. 2.00% C. 1.50% D. 1.25% 25. Under PD 957, the required setbacks of the sides and front are 2.00m and 3.00m respectively. What is then the required yard at the rear? A. 1.50 m B. 1.00 m C. 2.00 m D. 3.00 m 26. The agency mandated to administer take-outs of buyers originated by bank and developers, faced with administrative problems in load processing. It also provides construction and development finance for housing. A. NHMFC B. HDMF C. UHLP D. HIGC 27. What would be the minimum size of an office for 8 persons with a desk of 0.6m x 1.5m each. Layout should be two (2) rows, 1.0m aisle and a 1m setback from the door to the first table. A. 6.0m x 6.8m B. 4.0m x 7.0m C. 5.0m x 6.0m D. 4.0m x 7.2m 28. What particular Rule in the 2005 Revised IRR of PD1096 that regulates and determine percentage of site occupancy? A. Section 804 B. Section 801 C. Section 802 D. Section 803 29. Based on the existing regulations provided by the NBCP, how do you compute for the width of main exits in a building? A. not less than the total occupant load served divided by 165 B. Based on the occupant loads of existing floor, plus 50% occupant load of upper floor and lower floor and 25% of the next adjacent floors C. All of the above D. At least 2 exits with each exits at a minimum width of 0.90m 30. No point within a building, requiring dry standpipes, shall be more than ___m travel distance from a dry standpoint outlet connection. A. 25 B. 30 C. 40 D. 55