The purpose of this guide is to provide the basic operation for this equipment. For more detailed information, see the Operator's Manual. VOYAGE DATA RECORDER (VDR) English Model VR-7000 How to turn the power on/off, How to start/stop recording How to release the Fixed DRU How to turn the power on then record the data 1. Turn off the BATTERY and AC switches in that order to turn off the DCU power. 2. Remove the release pin. 3. Lift the release lever. 4. Lift the handle to separate the top of the DRU from the bottom of the DRU. 5. Cut the cable connected between the top and bottom of the DRU. 1. Open the DCU door with its key. 2. On the power control panel in the DCU, turn on the AC and BATTERY switches in that order. Confirm that the AC SUPPLY MAINS LED and BATTERY BACKUP LED on the power control panel light. Data is automatically recorded in the Fixed DRU, Float-free DRU and long term device. How to turn the power off then stop recording Recording is terminated only under the following conditions: - During essential maintenance while the vessel is in port. - When the vessel is laid-up. • Turn off the BATTERY and AC switches in that order. All brand and product names are trademarks, registered trademarks or service marks of their respective holders. Operator's Guide Handle Release lever Release pin Note: Do not turn off the system from the main breaker while the BATTERY switch is on. If this is done, the system operates on the batteries. The system stops after running on batteries after two hours. BATTERY BACKUP LED (BATT BACK UP) AC SUPPLY MAINS LED (AC MAINS) AC switch Note: Do not exert force on the opened DCU door. Force can damage the door. BATTERY switch Data Collecting Unit (DCU) Power control panel How to adjust the brilliance of the LCD and keys Main menu overview Self test BRILL Serial Monitor Sensor(LAN) Monitor TEST Analog Monitor MENU ESC BRILL LCD Max ► ◄ Min Key LCD Test BRILL TEST MENU ESC ACK Extract ENT Buzzer Test Max ▲ ▼ Min ENT Image Capture Status Audio Monitor Self Test 5 Digital Monitor Select a menu item. Life Parts List Status Monitor Key Beep 5 For LCD For keys How to extract the recorded data to the external media Select a test. or ENT ENT MENU ESC Note) Extract the data when the ship is stopped. Vibration, pitching, rolling, etc. can prevent smooth extraction. Open the DCU door with its key. Alert list The alert list provides information about active alerts. Alert List 1/ Alert ID Alert Name Time of last No.08 Sensor(LAN 15:24:37 412323 No.07 Sensor(LAN 15:24:37 412322 No.06 Sensor(LAN 15:24:37 412321 No.05 Sensor(LAN 15:24:37 412320 No.04 Sensor(LAN [MENU/ESC] : List ACK [ENT] : Input Long Term Device Long press: Moves the cursor continuously. Select a data source. Period Select ▲ ENT 1 hour ▼ (1~12) hour 15:24:37 Set the extraction time. User Disk Format? Extract Size/Disk Space ENT xxx, xxx, xxx, xxx byte/ xxx, xxx, xxx, xxx byte Yes How to see the detailed information for an alert Select an alert. ENT change ◄/► : Page ▲/▼ : Select The detailed information screen appears. Short press: Switches the page. Float DRU - Stops the flashing of the alert list. - Silences the alert buzzer. ENT Insert a USB flash memory to the USB port. Source Select Extract 2 412324 Short press: Selects a menu item. ENT MENU ESC Closes the detailed information screen. Select [Yes]. No ENT - Confirms a selection. - Silences the alert buzzer when there are unacknowledged alerts. The message “Extract Complete” appears after the data is extracted. Lock the DCU door. PUB. NO. OSE-44850-A (1407, YOTA) VR-7000 00017934410