Uploaded by Stevan Barovic

KONE APG DX Brochure 0322 v5 022323 tcm25-18782

advertisement
ARCHITECTURAL
PLANNING GUIDE
REDEFINING ELEVATOR TECHNOLOGY
Deliver a user experience that inspires, informs, and delights.
With KONE MonoSpace DX elevators you can harness the
power of digitalization to take the elevator journey far
beyond the ordinary.
Our goal is to create a user experience that both adds value to
a building and maximizes comfort and safety for passengers.
1
Not only are our elevators now enabled with connectivity,
we enhanced our elevator offering, so low, mid, and high
rise buildings can take advantage of our technology. Our
KONE MonoSpace 500 DX solution is enhanced to go
higher and faster*.
2
KONE ECO-EFFICIENT SOLUTIONS
1 A green hoisting system
The KONE EcoDisc permanent-magnet synchronous
motor, together with a vector-controlled drive system
and regenerative options, delivers eco-efficient operation
for every KONE DX elevator.
2 Regenerative drive
Regenerative drive technology recycles energy for
immediate reuse within a building and can cut elevator
energy consumption by up to 20%.**
3 Standby solutions
Lights, signalization and ventilation can consume a
considerable amount of electricity even when the
elevator is not moving. KONE’s standby solutions cut
energy consumption by powering down the equipment
when it’s not in use.
3
4 Eco-efficient car lighting
LED lighting is up to 80% more efficient and lasts up to
10 times longer than halogen lighting.
4
* Compared to KONE MonoSpace 500. Greater travel and speeds
equal to or greater than 500 FPM available in select markets.
** Calculation based on the following: 3,500 lb. capacity, 350 fpm,
7 landings, 72 feet of travel and 200,000 starts per year.
KONE ELEVATORS
KONE MonoSpace® 300 DX
ApplicationLow rise
Type
Machine room-less
Powered by
KONE EcoDisc
Capacity
2000 - 3500 lbs. (907 - 1588kg)
Speed
150 fpm (.75 m/s)
Landings
2 to 4
The KONE MonoSpace 300 DX is a cost-effective
elevator solution for low-rise buildings. It is durable,
provides a wide range of cab interiors, stylish
accessories, and easy to use signalization.
KONE MonoSpace® 500 DX
Application
Low- to mid-rise; new buildings
Type
Machine room-less
Powered by
KONE EcoDisc
Capacity
2000 – 5000 AIA lbs. (907 – 2268 kg)
Speed
150, 200, 350, 500* fpm
(.75, 1.0, 1.78, 2.54 m/s)
Landings
5 to 36
The KONE MonoSpace 500 DX combines our proven
eco-efficient technology with ride-comfort and design
innovations.
* Compared to KONE MonoSpace 500. Greater travel and
speeds equal to or greater than 500 FPM available in
select markets.
KONE MonoSpace® 500 Flex DX
Application
Low- to mid-rise; existing buildings
Type
Machine room-less
Powered by
KONE EcoDisc
Capacity
2000 – 5000 AIA lbs. (907 – 2268 kg)
Speed
150, 200, 350 fpm (.75, 1.0, 1.78 m/s)
Landings
2 to 15
Entrances
Option to reuse existing entrances
Flexible
Platforms
With accommodation of reduced
overhead dimension
KONE MonoSpace 500 Flex DX is a turnkey
full-replacement elevator solution for existing
hydraulic and traction elevator systems.
KONE MonoSpace® 700 DX
Application
Mid- to high-rise
Type
Machine room-less
Powered by
KONE EcoDisc
Capacity
2000 – 5000 AIA lbs. (907 – 2268 kg)
Speed
200, 350, 500 fpm (1.00, 1.78, 2.54 m/s)
Landings
6 to 36
KONE MonoSpace 700 DX is a fully
customizable machine room-less solution
for mid- to high-rise applications.
KONE MiniSpace™ DX
Application
Mid- to high-rise
Type
Overhead machine room
Powered by
KONE EcoDisc
Capacity
2000 – 5000 AIA lbs. (907 – 2268 kg)
Speed200, 350, 400, 500, 700 fpm
(1.00, 1.78, 2.00, 2.54, 3.56 m/s)
Landings
6 to 63
For the latest product information and interactive design tools, visit kone.us
KONE MiniSpace DX is an innovative,
space efficient, mid-to high-rise solution.
KONEMONOSPACE
MONOSPACE300
300
KONE
DX DX
®
®
CONFIGURATIONS
ATIONS && DIMENSIONS
DIMENSIONS
CONFIGUR
Max Travel(8) 48 ft. (14.6 m)
Speed(8)
150 fpm
(.75 m/s)
PASSENGER
PASSENGER
FRONT & REVERSE OPENING
FRONT OPENING
Max Landings 4
Car Height (F)
7 ft. 6 in.
(2286 mm)
Entrance Height (G)
7 ft.
(2134 mm)
(A)
(A) SEISMIC
(B)
(B) SEISMIC
(C)
(D)
(E)
CAPACITY
LBS. (kg)
OPENING
TYPE(10)
HOISTWAY
WIDTH (mm)
HOISTWAY
WIDTH (mm)
HOISTWAY
DEPTH (mm)
HOISTWAY
DEPTH (mm)
INTERIOR
WIDTH (mm)
INTERIOR
DEPTH (mm)
DOOR
WIDTH (mm)
STRETCHER
ACCOMMODATION(9)
2000 (907)
Side Opening
7'-4" (2235)
7'-9" (2362)
5'-9" (1753)
5'-9 1/2" (1766)
5'-8 7/8" (1750)
4'-4 7/16" (1332)
3'-0" (914)
NO
2500 (1134)
Side Opening or
Center Opening
8'-4" (2540)
8'-9" (2667)
5'-9" (1753)
5'-9 1/2" (1766)
6'-8 7/8" (2055)
4'-4 7/16" (1332)
3'-6" (1067)
NO
3000 (1361)
Side Opening or
Center Opening
8'-4" (2540)
8'-7" (2616)
6'-3" (1905)
6'-3 1/2" (1918)
6'-5 5/8" (1971)
5'-0 7/16" (1536)
3'-6" (1067)
NO
3500 (1588)
Side Opening or
Center Opening
8'-4" (2540)
8'-7" (2616)
6'-11" (2108)
6'-11" (2108)
6'-5 5/8" (1971)
5'-6 5/8" (1693)
3'-6" (1067)
YES(9)
2000 (907)
Side Opening
7'-4" (2235)
7'-9" (2362)
6'-3 3/4" (1924)
6'-3 3/4" (1924)
5'-8 7/8" (1750)
4'-4 7/16" (1332)
3'-0" (914)
NO
2500 (1134)
Side Opening or
Center Opening
8'-4" (2540)
8'-9" (2667)
6'-3 3/4" (1924)
6'-3 3/4" (1924)
6'-8 7/8" (2055)
4'-4 7/16" (1332)
3'-6" (1067)
NO
3000 (1361)
Side Opening or
Center Opening
8'-4" (2540)
8'-7" (2616)
6'-11 3/4" (2127) 6'-11 3/4" (2127)
6'-5 5/8" (1971)
5'-0 7/16" (1536)
3'-6" (1067)
NO
3500 (1588)
Side Opening or
Center Opening
8'-4" (2540)
8'-7" (2616)
6'-5 5/8" (1971)
5'-6 5/8" (1693)
3'-6" (1067)
NO
CLEAR OVERHEAD (H) AND PIT DEPTH (I)
2000 to 3500
(907 to 1588)
7'-6" (2284)
CONTROL SPACE
150 FPM (.75 m/s)
CAPACITY
LBS. (kg)
7'-6" (2286)
(J)
(K)
(L)
CAPACITY
LBS. (kg)
CONTROLLER SPACE
WIDTH
(mm)
DEPTH
(mm)
DOOR WIDTH
(mm)
Pit Depth
(mm)
Clear Overhead
(mm)
2000 to 3500
(907 to 1588)
Remote Closet
4'-1"
(1245)
1'-8"
(508)
3'-6"
(1067)
5'-0"
(1524)
11'-8"
(3556)(1)
2000 to 3500
(907 to 1588)
Adjacent or
Remote Room
5'-0"
(1524)
Dimension (B)
3'-0"
(914)
Visit kone.us for the latest project-specific details, CAD drawings, BIM models, CSI specifications, electrical data, reaction loads and building access requirements.
Notes
(1) An 8” inch tall hoist beam is required for installation (by others). Dimension
(H) reflects 11’-8” clearance under hoist beam. This clearance is available with
a flush or moveable hoist beam.
(2) If an EBD (Emergency Battery Device) is required please contact your KONE
Sales Professional for further detail regarding dimensions, (J) and (L).
(3) The published hoistway (A) dimensions represent the minimum clear inside
requirements. Construction efficiencies can be realized by increasing these
dimensions by up to 2” (51 mm).
(4) For pit depths less than 5’ (1524 mm) please contact a KONE Sales Professional.
(5) The published interior width (C) and depth (D) dimensions represent the
minimum clear inside requirements without raised panels. For interior width
(C) and Depth (D) dimensions with raised panels please contact a KONE sales
Professional.
(6) A pit ladder wall pocket may be required. Please contact a KONE sales
Professional.
(7) Contact your local KONE Sales Professional regarding local code variations
when utilizing the integrated remote closet options.
(8) If IBC (International Building Code) 2018 or ASME A17.1-2019/CSA B44-19
code is applicable, contact your local sales professional for controller space
configurations.
(9) Stretcher accessibility based only for side opening type and International /
California Building Code specified 24 inch by 84 inch stretcher with 5 inch
degree radius corners. Customers in Canada, please review stretcher
compliance with your local sales representatives.
(10) All KONE MonoSpace 300 DX elevators utilize a single speed door.
KONE MonoSpace 300 DX
Plan Views
Section View
(3) (5)
(A)
(1)
(C)
(D) (B) (5)
(H)
(E)
(F)
(G)
Integrated Control
Solution (standard)
(K)
(L)
Remote Control Closet
(option 1) (2) (7)
(J)
TRAVEL
(J)
(4)
(B)
(G)
(I)
I
Adjacent or Remote
Control Room
(option 2) (2) (7)
(L)
KONE
kone.us
Copyright © 2022 KONE Inc. This publication is for general informational purposes only. KONE Inc. reserves the right to alter the product design and specifications
without prior notice. Minor differences between printed and actual colors may exist. KONE MonoSpace® DX is a registered trademark of KONE Corporation.
SF3071- Rev 0322
Printed in the U.S.
KONE
MONOSPACE
500
DX
KONE MONOSPACE 500 DX
®
®
CONFIGUR ATIONS & DIMENSIONS
CONFIGUR ATIONS & DIMENSIONS
Travel
(8)
MaxMax
Travel
150 ft. (45.7 m)
(8)
150 ft. (45.7 m)
Max Landings(8) 15 (8)
Max Landings
15
Speed
(8)
Speed
150, 200, 350 fpm
150, 200, 350 fpm
(.75, 1.0, 1.78 m/s)
(.75, 1.0, 1.78 m/s)
(8)
PASSENGER
PASSENGER
SERVICE
SERVICE
PASSENGER
PASSENGER
SERVICE
SERVICE
Front & Reverse Opening
FRONT & REVERSE OPENING
Front Opening
FRONT OPENING
A
CarHeight
Height
Car
(F) F
8,
9
or
10
8, 9 or 10 ft.ft.
(2438, 2743 or 3048 mm)
(2438, 2743 or 3048 mm)
(A) A SEISMIC
(A) SEISMIC
B
(B)
B SEISMIC
(B) SEISMIC
C (C)
D (D)
E (E)
CAPACITY
OPENING
HOISTWAY
INTERIOR
INTERIOR
DOOR WIDTH
STRETCHER
CAPACITY
OPENING
HOISTWAY HOISTWAY
HOISTWAY HOISTWAY
HOISTWAY HOISTWAY
HOISTWAY
INTERIOR
INTERIOR
DOOR
STRETCHER (10)
LBS.LBS.
(kg)(kg)
TYPE (mm)TYPEWIDTH
(mm)
WIDTH (mm)
(mm)(mm) WIDTHWIDTH
(mm)
(mm)
(mm)
†
WIDTH (mm)
WIDTH (mm)DEPTH (mm)
DEPTH (mm) DEPTH DEPTH
(mm) DEPTH
DEPTH
(mm)
WIDTH (mm) ACCOMMODATION
ACCOMMODATION(10)
57
27
2000 (907)
SSP
7'-6" (2286)
7'-11" (2413)
5'-9" (1753)
5'-9 1⁄ 2" (1766)
5'-8
⁄
64
"
(1750)
4'-4
⁄
64
"
(1332)
3'-0"
(914)
No
1
2000 (907)
SSP
7'-6" (2286)
7'-11" (2413)
5'-9" (1753)
5'-8 7⁄8" (1750)
4'-4 7⁄ 16" (1332)
3'-0" (914)
No
1 5'-9 ⁄ 2 " (1766)
27
2500
(1134)
SSP-COSSP / CO
8'-6" (2591)
8'-11" (2718)
(1766)
6'-8 29⁄6'-8
32" (2055)
⁄ 64" 7(1332)
(1067)
No
1
7
2500
(1134)
8'-6" (2591)
8'-11" (2718)5'-9" (1753)
5'-9" (1753)5'-9 1⁄ 2"5'-9
⁄2" (1766)
⁄8" (2055)4'-4 274'-4
⁄ 16" (1332) 3'-6"3'-6"
(1067)
No
47
(10)
2500 IBC (1134) (10) SSP
8'-11" (2718)
9'-5" (2870)
5'-9" (1753)
5'-9 ⁄ 2" (1766)
6'-11 ⁄ 64" (2127)
4'-4 ⁄ 64" 7(1332)
3'-6" (1067)
Yes
1
3
SSP
8'-11" (2718)
9'-5" (2870)
5'-9" (1753)
5'-9 ⁄2" (1766) 196'-11 ⁄4" (2128)
4'-4 ⁄ 16" (1332)
3'-6" (1067)
Yes
2500 IBC (1134)
3000 (1361)
SSP-CO
8'-6" (2591)
8'-9" (2667)
6'-3" (1905)
6'-3 1⁄ 2" (1918)
6'-5 ⁄ 32" (1971)
5'-0 29⁄ 64" 7(1536)
3'-6" (1067)
No
1
5
⁄2" (1918)
⁄8" (1971) 5'-6 5'-0
⁄ 16" (1536) 3'-6"3'-6"
(1067)
No
3000
(1361)
8'-6" (2591)8'-9" (2667)
8'-9" (2667)6'-11" (2108)
6'-3" (1905) 6'-11" 6'-3
5
3500
(1588)
SSP-COSSP / CO
8'-6" (2591)
(2108)
6'-5 19⁄6'-5
32" (1971)
⁄ 8" (1693)
(1067)
Yes
5
5
⁄8" (1971) 5'-6 55'-6
⁄8" (1693) 4'-0"3'-6"
(1067)
Yes
3500
(1588)
8'-6" (2591)
8'-9" (2667)6'-11" (2108)
6'-11" (2108)6'-11" (2108)
6'-11" (2108)7'-6 45⁄ 6'-5
4000
(1814)
CO SSP / CO
9'-8" (2947)
9'-8" (2947)
64" (2304)
⁄ 8" (1693)
(1219)
Yes
11
5
4000 (1814)
CO
9'-8" (2947)
9'-8" (2947)
6'-11" (2108)
6'-11" (2108)
7'-6 ⁄ 16" (2304)
5'-6 ⁄8" (1693)
4'-0" (1219)
Yes
4000 (1814)
2SP
7'-8" (2337)
7'-8" (2337)
9'-2" (2794)
9'-2" (2794)
5'-7 3⁄ 32" (1704)
7'-7 29⁄ 32" 7(2335)
4'-0" (1219)
Yes
4000 (1814)
2SP
7'-8" (2337)
7'-8" (2337)
9'-2" (2794)
9'-2" (2794)
5'-7 1⁄8" (1705)
7'-7 ⁄8" (2334)
4'-0" (1219)
Yes
4500 (2041)
2SP
7'-8" (2337)
7'-8" (2337)
9'-8" (2946)
9'-8" (2946)
5'-7 3⁄ 32" (1704)
8'-1 13⁄ 16" 7(2485)
4'-0" (1219)
Yes
1
4500 (2041)
2SP
7'-8" (2337)
7'-8" (2337)
9'-8" (2946)
9'-8" (2946)
5'-7 ⁄8" (1705)
8'-1 ⁄8" (2486)
4'-0" (1219)
Yes
5000 (2268)(9) (9)
2SP
7'-10" (2388)
7’-10" (2388)
10'-2 1⁄ 2" (3112)
10'-2 1⁄ 2" (3112)
5'-7 3⁄ 32" (1704)
8'-9 21⁄ 32" 11(2684)
4'-6" (1372)(9) (9)
Yes
1
1
1
(2388)
7'-10" (2388)
⁄2" (3112)
10'-2
⁄2" (3112)
⁄8" (1705)9'-0 8'-9
⁄ 16" (2685) 4'-6"4'-6"
(1372)
Yes
(2268)
7
(9)
50005000
AIA (2268)
2SP 2SP
7'-10 5⁄ 16" 7'-10"
(2396)
7'-11 1⁄ 2" (2426)
10'-5 1⁄ 1610'-2
" (3177)
10'-5 1⁄ 16
" (3177)
5’-9 13⁄5'-7
32" (1763)
⁄ 16" (2755)
(1372)
Yes
5
1
1
1
7
7
(9)
5000 AIA (2268)
2SP
7'-10 ⁄ 16" (2396)
7'-11 ⁄2" (2426)
10'-5 ⁄ 16" (3177) 10'-5 ⁄ 16" (3177)
5'-9 ⁄ 16" (1764)
9'-0 ⁄ 16" (2755)
4'-6" (1372)
Yes
2000 (907)
SSP
7'-6" (2286)
7'-11" (2413)
6'-3 3⁄ 4" (1924)
6'-3 3⁄ 4" (1924)
5'-8 57⁄ 64" (1750)
4'-4 27⁄ 64" 7(1332)
3'-0" (914)
No
3
3
7
2000 (907)
SSP
7'-6" (2286)
7'-11" (2413) 3 6'-3 ⁄4" (1924) 3 6'-3 ⁄4" (1924) 29 5'-8 ⁄8" (1750)
4'-4 ⁄ 16" (1332)
3'-0" (914)
No
2500 (1134)
SSP-CO
8'-6" (2591)
8'-11" (2718)
6'-3 ⁄ 4" (1924)
6'-3 ⁄ 4" (1924)
6'-8 ⁄ 32" (2055)
4'-4 27⁄ 64" 7(1332)
3'-6" (1067)
No
3
3
7
2500 (1134)
SSP / CO
8'-6" (2591)
8'-11" (2718) 3 6'-3 ⁄4" (1924) 3 6'-3 ⁄4" (1924)
6'-8 ⁄8" (2055)
4'-4 ⁄ 16" (1332)
3'-6" (1067)
No
2500 IBC (1134)(5)(10)(5)(10) SSP
8'-11" (2718)
9'-5" (2870)
6'-3 ⁄ 4" (1924)
6'-3 ⁄ 4" (1924)
6'-11 47⁄ 64" (2127)
4'-4 27⁄ 64" 7(1332)
3'-6" (1067)
Yes
3
3
3
SSP
8'-11" (2718)
9'-5" (2870) 3 6'-3 ⁄4" (1924) 3 6'-3 ⁄4" (1924) 196'-11 ⁄4" (2128)
4'-4 ⁄ 16" (1332)
3'-6" (1067)
Yes
2500 IBC (1134)
3000 (1361)
SSP-CO
8'-6" (2591)
8'-9" (2667)
6'-11 ⁄ 4" (2127)
6'-11 ⁄ 4" (2127)
6'-5 ⁄ 32" (1971)
5'-0 29⁄ 64" 7(1536)
3'-6" (1067)
No
3
5
⁄4" (2127)
⁄8" (1971) 5'-6 5'-0
⁄ 16" (1536) 3'-6"3'-6"
(1067)
No
(1361)
8'-6" (2591)8'-9" (2667)
8'-9" (2667)7'-6" (2286)
6'-11 3⁄4" (2127)7'-6" 6'-11
5
(10)
35003000
(1588)
SSP-COSSP / CO
8'-6" (2591)
(2286)
6'-5 19⁄6'-5
32" (1971)
⁄ 8" (1693)
(1067)
Yes*
(10)
5
5
8'-6" (2591)
8'-9" (2667)7'-6" (2286)
7'-6" (2286) 7'-6" (2286)
7'-6" (2286)7'-6 45⁄ 6'-5
⁄8" (1971) 5'-6 55'-6
⁄8" (1693) 4'-0"3'-6"
(1067)
Yes*
3500
(1588)
4000
(1814)
CO SSP / CO
9'-8" (2947)
9'-8" (2947)
64" (2304)
⁄ 8" (1693)
(1219)
Yes
4000 (1814)
CO
9'-8" (2947)
9'-8" (2947)
7'-6" (2286)
7'-6" (2286)
7'-6 11⁄ 16" (2304)
5'-6 5⁄8" (1693)
4'-0" (1219)
Yes
4000 (1814)
2SP
7'-8" (2337)
7'-8" (2337)
10'-2 1⁄ 8" (3102)
10'-2 1⁄ 8" (3102)
5'-7 3⁄ 32" (1704)
7'-7 29⁄ 32" 7(2335)
4'-0" (1219)
Yes
1
1
1
4000
(1814)
7'-8" (2337)
7'-8" (2337)
⁄8" (3102)
10'-2
⁄8" (3102)
⁄8" (1705)8'-1 137'-7
⁄8" (2334) 4'-0"4'-0"
(1219)
Yes
4500
(2041)
2SP 2SP7'-8" (2337)
7'-8" (2337)
10'-8 1⁄ 1610'-2
" (3252)
10'-8 1⁄ 16
" (3252)
5'-7 3⁄ 325'-7
" (1704)
⁄ 16" 7(2485)
(1219)
Yes
1
1
1
4500 (2041)
2SP
7'-8" (2337)
7'-8" (2337) 7 10'-8 ⁄ 16" (3252) 710'-8 ⁄ 16" (3252) 3 5'-7 ⁄8" (1705)
4'-0" (1219)
Yes
218'-1 ⁄ 8" (2486)
(9)
5000 (2268)(9) (9)
2SP
7'-10" (2388)
7’-10" (2388)
11'-3 ⁄ 8" (3451)
11'-3
⁄
8" (3451)
5'-7
⁄
32" (1704)
8'-9
⁄
32" (2684)
4'-6"
(1372)
Yes
7
7
1
11
(9)
7'-10" (2388)
⁄8" (3451)
11'-3
⁄8" (3451)
⁄8" (1705)9'-0 8'-9
⁄ 16" (2685) 4'-6"4'-6"
(1372)
Yes
(2268)
7
(9)
50005000
AIA (2268)
2SP 2SP
7'-10 5⁄ 16" 7'-10"
(2396)(2388)
7'-11 1⁄ 2" (2426)
11'-6 11⁄ 1611'-3
" (3522)
11'-6 11⁄ 16
" (3522)
5'-9 13⁄5'-7
32" (1763)
⁄ 16" (2755)
(1372)
Yes
5000 AIA (2268)
2SP
7'-10 5⁄ 16" (2396)
7'-11 1⁄2" (2426) 11'-6 11⁄ 16" (3522) 11'-6 11⁄ 16" (3522)
5'-9 7⁄ 16" (1764)
9'-0 7⁄ 16" (2755)
4'-6" (1372)(9)
Yes
† SSP = Single Speed Side Opening / CO = Single Speed Center
Opening
/ 2SP = Two Speed
Side Opening
CLEAR
OVERHEAD
PIT DEPTH
H AND
Visit kone.us for the latest
project-specific details, CAD
drawings, BIM models, CSI
electrical
data,
Visitspecifications,
kone.us for the
latest projectreaction
loads
anddrawings,
building BIM
specific
details,
CAD
accessCSI
requirements.
models,
specifications, electrical
data, reaction loads and building
access requirements.
I
150 FPM (0.75 M/S)
CLEAR OVERHEAD
(H)
CAPACITY
PIT DEPTH
LBS. (kg)
(mm)
2000 to 2500
CAPACITY 5'-0"
(907 to 1134)
LBS. (kg) (1524)
3000 to 3500
5'-0"
2000 to 2500(1524)
(1361 to 1588)
(907 to 1134)
4000 to 5000 AIA
5'-0"
(1814 to 2268)
3000 to 3500(1524)
(1361 to 1588)
(11)
CONTROL
SPACE
4000
to 5000 AIA
(1814 to 2268)
CAPACITY
LBS. (kg)
2000 to 5000 AIA
(907 to 2268)
CONTROL SPACE (11)
200 FPM (1.00 M/S)
AND PIT DEPTH
CLEAR (I)
OVERHD (mm)
150 FPM (0.75 M/S)
PIT DEPTH
(mm)
5'-0"
(1524)
CONTROLLER
SPACE
13'-8"
(4166)
remote closet
200 FPM (1.00 M/S)
2000 to 5000 AIA
(907 to 2268)
Remote Room
5'-0"
(1524)
PIT DEPTH
(mm)
13'-4"
(3988)CLEAR
OVERHD (mm)
13'-4"
(3988)13'-4"
(4064)
13'-8"
(4166)13'-4"
(4064)
J
5'-0"
WIDTH (1524)
(mm)
4'-0"
(1219)(11)
350 FPM (1.78 M/S)
CLEAR
OVERHD (mm)
13'-0"
5'-0"
PIT DEPTH(3962)
CLEAR (1524) PIT DEPTH
(mm)
OVERHD (mm)
(mm)
13'-0"
5'-0"
5'-0" (3962)
13'-0" (1524) 5'-0"
(1524)
(3962)
(1524)
13'-8"
5'-0"
5'-0" (4166)
13'-0" (1524) 5'-0"
(1524)
(3962)
(1524)
2000 to 5000 AIA
adjacent or remote room
(907CAPACITY
to 2268) LBS. (kg)
CONTROLLER SPACE
Notes
EntranceHeight
Height
Entrance
(G)G
7,
8
or
9
ft.
7, 8 or 9 ft.
(2134, 2438 or 2743 mm)
(2134, 2438 or 2743 mm)
5'-6"
PIT DEPTH
(1676)
(mm)
5'-6"
5'-6"
(1676)
(1676)
5'-6"
(1676)
5'-6"
(1676)
K
13'-8"
(4166)
DEPTH
(mm)
(J)
WIDTH (mm)
4'-1"
(1245)(11)
1'-8"
(508)(11)
CLEAR
OVERHD (mm)
350 FPM (1.78 M/S)
13'-6"
CLEAR
(4115)
OVERHD (mm)
13'-6"
13'-6"
(4115)
(4115)
13'-8"
(4166)
13'-6"
(4115)
L 13'-8"
5'-6"
(1676) DOOR WIDTH
(4166)
(mm)
(K)
dimension (B)
DEPTH (mm)
1'-8"
(508)(11)
3'-6"
(1067)(11)
(L)
3'-0"
(11)
(914)
DOOR
WIDTH (mm)
3'-6"
(1067)(11)
(1) A hoist beam (by KONE) is required for installation 2000
(by others).
(7) All dimensions are based on
an 8'-0" (2438 mm) cab with a 7'-0" (2134
HAdjacent
to 5000 Dimension
AIA
5'-0"
3'-0" mm)
Dimension (B)
or Remote Room
(907 to 2268)
(1524)
(914)(11)
reflects clear under hoist beam.
door. Alternate car and door
heights are available, but will affect dimension
H.
Notes
(2)
If an Emergency Battery Device (EBD) is required, please contact your KONE
Professional
further
detail regarding
dimensions
and L .
H , J , Dimension
(1) Sales
A hoist
beam (by for
KONE)
is required
for installation
(by others).
(H) reflects
clearAunder
hoistdimension
beam. represents the optimum clear inside
(3) The
published
hoistway
(8) 150 fpm (.75 m/s) only available up to 85 ft. (25 m) of travel and
10 dimensions
landings. 200
(1.00
m/s)
available
to cab
100with
ft. (30.5
m)(2134
of
(7) All
arefpm
based
on an
8'-0"
(2438 up
mm)
a 7'-0"
mm
travel Alternate
and 12 landings.
door.
car and door heights are available, but will affect dimension (H).
(2) requirements
If an Emergency
Destination
is required,
andBattery
maybe Device
reduced(EBO)
by uportoKONE
2” (51mm).
However,
this may
pleaseincontact
your KONE
Sales Professional for further detail regarding
result
construction
inefficiencies.
dimensions (H), (J) and (L).
(4) The published interior width C and depth D dimensions represent the
(3) minimum
The published
hoistway
dimension
represents
optimum
clear inside
clear (A)
inside
requirements
without
raised the
panels.
For interior
requirements and maybe reduced by up to 2” (51mm). However, this may
width C and depth D dimensions with raised panels please contact
result in construction inefficiencies.
a KONE Sales Professional.
(4) The published interior width (C) and depth (D) dimensions represent the
(5)2500
LB. IBC
reverse
must be
diagonally
opposed.
For interior
all other front
minimum
clear
insideopening
requirements
without
raised
panels. For
and
reverse
opening
width
is valid contact
for directly
A please
width
(C) and
depth configurations,
(D) dimensions hoistway
with raised
panels
opposed
openings
only. If diagonally opposed openings are required, please
a KONE Sales
Professional.
contact your KONE Sales Professional.
(5) 2500 LB. IBC (International Building Code) reverse opening must be
diagonally
opposed.
For all
and reverseis opening
configurations,
(6 The
published
minimum
pitother
depthfront
based upon
slide
I dimension
hoistwayFor
width
(A) is valid
for directly
opposed
openings
only.
If diagonally
guides.
minimum
pit depth
roller guides
please
contact
I with
openings
are required, please contact your KONE Sales Professional.
aopposed
KONE Sales
Professional.
(9) 150
4'-0"fpm
(1219
mm)
also up
available.
(8)
(.75
m/s)door
onlywidth
available
to 85 ft. (25 m) of travel and 10 landings.
fpm (1.00
m/s) available
upinternational
to 100 ft. (30.5
m) ofcode
travel(IBC)
and and
12 landings.
(10) 200
Stretcher
accessibility
based on
building
(6) The published minimum pit depth (I) dimension is based upon slide guides.
For minimum pit depth (I) with roller guides please contact a KONE Sales
Professional.
California
Building
Codewidth
specified,
24 inch by 84 inch stretcher — with
(9) 4’-0”
(1219
mm) door
also available.
5-degree radius
corners.
Elevator
car must utilize
a sidecode
slide (IBC)
door with
(10) Stretcher
accessibility
based
on international
building
and the
exception Building
of the 4000
LB.specified,
passenger24shaped
car.
Canada
(NBCC)
2500 LB.
California
Code
inch by
84Ininch
stretcher
- with
and larger
elevators
with
single car
slidemust
doors
meeta Canadian
5-inch
radius
corners.
Elevator
utilize
side slide stretcher
door withrule
theof
exception
the 4000 LB. passenger shaped car. In Canada (NBCC) 2500
2010mm xof610mm.
LB. and larger elevators with single slide doors meet Canadian stretcher
(11) If IBC 2018 or ASME A17.1-2019/CSA B44-19 code is applicable, contact
rule of 2010mm x 610mm.
your local sales professional for controller space configurations.
(11) If IBC (International Building Code) 2018 or ASME A17.1-2019/CSA B44-19
code
is LB.
applicable,
contactelevators
your localneeds
sales to
professional
for controller
*3,500
Front / reverse
have diagonal
opposed space
doors
configurations.
and a wider hoistway width of 8’-9” (8’-11” if seismic) to accommodate a
stretcher.
KONE Sales
Professional
for more
information.
* 3,500
LB. Please
Front /contact
reverse aelevators
needs
to have diagonal
opposed
doors
and a wider hoistway width of 8' -9" (8' -11" if seismic) to accommodate a
stretcher. Please contact a KONE Sales Professional for more information.
(4)
E
(A)
Section
Sectionview
View
A
C
(1)
(1)
(C)
(E)
D B
(4)
(2) (7) H
(2) (7)
F
(H)
G
(F)
(G)
(D) (B) (4)
(2)
E
Integral Control Solution (standard)
(E)
Integrated Control
Solution (standard)
(K)
K
L
J
(2)
TRAVEL
(K)
G
TRAVEL
(G)
(6) (11) I
(6) (12)
(I)
I
Remote Control Closet (option 1)
(L)
(J)
(2)
(2)
J
Remote Control Closet
(option 1)
(2)
(12)
(13)
(J)
B
Notes, continued:
Please consult a KONE Sales Professional regarding:
Notes, continued:
(12) Pit depths less than 5'-0" (1524 mm).
(B)
Adjacent or Remote
Control Room
(option 2)
L
Adjacent or Remote Control Room
(option 2)
(L)
Please consult(13)
a KONE
Sales space
Professional
regarding:
Occupied
beneath
the hoistway.
(11) Pit depths
lessLocal
thancode
5'-0" variations
(1524 mm).
(14)
when utilizing the integrated,
integral
andthe
remote
closet options.
(12) Occupied space
beneath
hoistway.
(13) Local code variations when utilizing the integrated, integral and
remote closet options.
For configuration guidance or more
information scan this code or visit
our website to get in touch with a
KONE Sales Professional:
kone.us/ms500dx
KONE
kone.us
Copyright © 2022 KONE Inc. This publication is for general informational purposes only. KONE Inc. reserves the right to alter the product design and specifications
without prior notice. Minor differences between printed and actual colors may exist. KONE MonoSpace® DX is a registered trademark of KONE Corporation.
SF2982 - Rev 0822
Printed in the U.S.
KONE MonoSpace 500 DX
PlanViews
views
Plan
(4)
KONE MONOSPACE 500 FLEX DX
®
KONE MonoSpace 500 Flex DX is a full replacement elevator
solution for existing buildings.
KONE MonoSpace 500 Flex DX advantages
n
Replacing your elevators
Instead of replacing your aging elevators with similar
technology, KONE offers you an advanced, state-of-the-art
solution. Our innovative machine room-less design is the first
turnkey full replacement elevator solution for existing hydraulic
and traction elevator systems. Thanks to the revolutionary
KONE EcoDisc® motor, KONE MonoSpace 500 Flex DX is
designed to fit into existing hoistways.
From the initial planning stages and site surveys through final
completion, KONE works to ensure the entire process is
well-planned and streamlined in order to minimize disruption
to your building.
F
or the owner: Minimized building disruption, increased
property value, accommodation of reduced overhead
dimension.
Building owners who purchase the Integrated Control
Solution (ICS) will gain back additional space in their facility,
no longer requiring a machine room. Therefor mandatory
code related updates for machine room are not needed
either. The new space can be used to fit the building
owners needs.
n
n
F
or the tenant: Smoother, quieter ride, no hydraulic oil
odor, optimum stopping accuracy, sophisticated car features
F
or the environment: No hydraulic oil, energy-efficient,
ability to recycle existing elevator where feasible, option to
retain and reuse existing entrances
KONE MonoSpace 500 Flex DX
1
2
6
8
1 Space efficiency
With the machine in the hoistway and the controller
accessible from the top landing, the space previously needed
for a dedicated machine room or control space can be
allocated for more profitable uses.
2 Energy efficiency
In addition to the efficient KONE EcoDisc® hoisting machine,
advanced standby solutions save energy by powering down
the equipment when it’s not in use.
3 Minimized disruption
The compact design fits inside existing hoistways, minimizing
the need for modifications.
4 Reusable entrances
The ability to interface with most existing entrances reduces
the need for significant structural modifications.
3
5
4
5 Modern, code-compliant
Modern, simple and code-compliant operating displays.
6 High performance
Passengers enjoy smooth acceleration and deceleration,
accurate leveling and a quiet, comfortable ride.
7 No oil
When applicable, the existing hydraulic cylinder is drained of
all oil and capped, ensuring oil-free, environmentally friendly
operation.
8 Integrated Control Solution (ICS)
An integrated control solution is available for units up to 350
FPM and 3500 lb. capacity. Use of ICS allows KONE to return
existing machine room space back to the building for
ownership’s use.
9 Destination control
The KONE Destination can significantly improve convenience
in your building while enhancing the appearance of your
lobby. Please consult your KONE Sales Professional.
7
KONE MONOSPACE 700 DX
®
®
MACHINE AT REAR CONFIGUR ATION & DIMENSIONS
MACHINE AT REAR CONFIGUR ATION & DIMENSIONS
Available in passenger shape with front opening option
Max Travel 300 ft. (91.4 m)
Speed
200, 350,
500 fpm
FRONT
OPENING
(1.0,CAPACITY
1.78, 2.54OPENING
m/s)
Travel
MaxMax
Landings
36
300 ft. (91.4 m)
PASSENGER
Max Landings
36
lbs. (kg)
TYPE
2000 (907)
2500 (1134)
3000 (1361)
3500 (1588)
4000(A)
(1814)
SSP
SSP-CO
SSP-CO
SSP-CO
CO
A
HOISTWAY
WIDTH (mm)
7'-4" (2235)
8'-4" (2540)
8'-4" (2540)
8'-4" (2540)
(2845)
(A) 9'-4"
SEISMIC
Available
Speed in passenger shape with front opening option
PASSENGER
200, 350, 500 fpm
FRONT
(1.00,OPENING
1.78, 2.54 m/s)
CAPACITY F
Car Height
LBS. (kg)
8, 9 or 10 ft.
2000
(907)
(2438, 2743
or 3048
mm)
2500 (1134)
OPENING
TYPE†
HOISTWAY
7'-4" (2235)
HOISTWAY
CLEAR
Entrance
Height G SSP / CO
CAPACITY
DEPTH PIT DEPTH8'-8"
3000 (1361)
8'-4"PIT
(2540)
(2642)
OVERHD
lbs. (kg)
(mm)
(mm)
(mm)
7, 8 or 9 ft.
3500 (1588)
SSP / CO
8'-4" (2540)
8'-8" (2642)
2000
5'-3"
5'-3"
15'-6"
(2134, 2438
(907)
(1600)
(1600)
(4724)
4000mm)
(1814)
CO
9'-4" (2845)
9'-8" (2946)
or 2743
2500
5'-3"
5'-3"
15'-0"
(1134)
(1600)
(1600)
(4572)
† SSP = Single Speed Side Opening / CO = Single Speed Center Opening
3000
5'-3"
5'-3"
15'-2"
(1361)
(1600)
(1600)
(4623)
3500
5'-5"
5'-5"
14'-10"
CLEAR OVERHEAD (H) AND PIT DEPTH (1588)
(I)
(1651)
(1651)
(4521)
Visit kone.us for the latest
4000
5'-6"
5'-6"
15'-1"
200
FPM
(1.00
M/S)
project-specific details, BIM
(1814)
(1676)
(1676)
(4597)
(H)
(H) SEISMIC
CONTROL SPACE
(I)
WIDTH (mm)
DEPTH (mm)
WIDTH (mm)
6'-8" (2032)
6'-8" (2032)
7'-2" (2184)
7'-10" (2388)
7'-10" (2388)(C)
5'-8½" (1740)
6'-8½" (2045)
6'-8½" (2045)
6'-8½" (2045)
7'-8½" (2350)
4'-3¼" (1302)
4'-3¼" (1302)
4'-9¼" (1454)
5'-5¼" (1657)
5'-5¼"
(D) (1657)
3'-0" (914)
3'-6" (1067)
3'-6" (1067)
3'-6" (1067)
4'-0" (1219)
(E)
HOISTWAY
DEPTH (mm)
200 FPM7'-8"
(1.00
M/S)
(2337)
Entrance Height (G)
7, 8 or 9 D
ft.
C
E
(2134,
2438
or 2743 mm)
INTERIOR
INTERIOR
DOOR
DEPTH (mm)
7'-8" (2337)
8'-8" (2642)
8'-8" (2642)
8'-8" (2642)
9'-8" (2946)
(B)
I
I SEISMIC
H H SEISMIC
8'-4" (2540)
8'-8" (2642)
SSP / CO
DEPTH
PIT DEPTH
reaction loadsPITand
building
(mm)
(mm)
access requirements.
WIDTH (mm)
(mm)
CLEARWIDTH
OVERHEAD
PIT(mm)
DEPTH I
H ANDWIDTH
SSP
Models, CAD drawings,
CAPACITY
(I)
(I) SEISMIC
specifications,
electrical data,
LBS.
(kg)
Car Height (F)
8,A 9SEISMIC
or 10 ft.
B
(2438,
2743 or HOISTWAY
3048 mm)
HOISTWAY
INTERIOR
WIDTH (mm)
INTERIOR
DEPTH (mm)
DOOR
WIDTH (mm)
350 FPM (1.78
M/S)
6'-8" (2032)
5'-8½"
(1740)
500
FPM (2.54 M/S)
4'-3¼"
(1302)
3'-0" (914)
I SEISMIC
6'-8"I (2032)
SEISMIC
I4'-3¼"I (1302)
H (2045)
H SEISMIC
6'-8½"
H
H SEISMIC
3'-6"
(1067)
CLEAR
CLEAR
CLEAR
CLEAR
CLEAR
DEPTH
PIT DEPTH OVERHD
DEPTH
DEPTH OVERHD
7'-2"
(2184)
6'-8½" (2045)
4'-9¼"PIT
(1454)
3'-6"OVERHD
(1067)
OVERHD PIT
OVERHD PIT(mm)
(mm)
(mm)
(mm)
(mm)
(mm)
(mm)
(mm)
(mm)
7'-10" (2388)
6'-8½" (2045)
5'-5¼" (1657)
3'-6" (1067)
16'-11"
5'-7"
6'-7"
16'-11"
16'-11"
5'-7"
6'-7"
16'-11"
16'-11"
(5156)
(1702)
(2007)
(5156)
(5156)
(1702)
(2007)
(5156)
(5156)
7'-10" (2388)
7'-8½" (2350)
5'-5¼" (1657)
4'-0" (1219)
16'-11"
5'-5"
6'-5"
16'-7"
16'-11"
5'-5"
6'-5"
16'-7"
16'-11"
(5156)
(1651)
(1956)
(5055)
(5156)
(1651)
(1956)
(5055)
(5156)
16'-11"
5'-5"
6'-5"
16'-10"
16'-11"
5'-5"
6'-5"
16'-10"
16'-11"
(5156)
(1651)
(1956)
(5131)
(5156)
(1651)
(1956)
(5131)
(5156)
16'-11"
5'-5"
6'-5"
16'- 4"
16'-11"
5'-5"
6'-5"
16'- 4"
16'-11"
(5156)
(1651)
(1956)
(4978)
(5156)
(1651)
(1956)
(4978)
(5156)
16'-11"
5'-6"
6'-6"
16'-7"
16'-11"
7'-5"
8'-5"
16'-11"
16'-11"
350
FPM
(1.78
M/S)
500
FPM
(2.54
M/S)
(5156)
(1676)
(1981)
(5055)
(5156)
(2261)
(2565)
(5156)
(5156)
(I) SEISMIC
(H)
J
(H) SEISMIC
(I)
K
(I) SEISMIC
(H)
L
(H) SEISMIC
3000 (1361)
CLEAR OVERHD CLEAR OVERHD
(mm) CAPACITY(mm)
lbs. (kg)
5'-3" (1600) 5'-3" (1600) 15'-6" (4724)
16'-11"
2000 to
4000 (5156)
(907 to 1814)
5'-3" (1600) 5'-3" (1600) 15'-0" (4572) 16'-11" (5156)
2000 to 4000
(907 to 1814)
5'-3" (1600) 5'-3" (1600) 15'-2" (4623) 16'-11" (5156)
3500 (1588)
5'-5" (1651) 5'-5" (1651) 14'-10" (4521) 16'-11" (5156) 5'-5" (1651) 6'-5" (1956) 16'- 4" (4978) 16'-11" (5156) 5'-5" (1651) 6'-5" (1956) 16'- 4" (4978) 16'-11" (5156)
4000 (1814)
Notes
5'-6" (1676) 5'-6" (1676) 15'-1"
(4597) 16'-11" (5156) 5'-6" (1676) 6'-6" (1981) 16'-7" (5055) 16'-11" (5156) 7'-5" (2261) 8'-5" (2565) 16'-11" (5156) 16'-11" (5156)
2000 (907)
2500 (1134)
PIT DEPTH
PIT DEPTH
CLEAR OVERHD CLEAR OVERHD
PIT DEPTH
PIT DEPTH
CLEAR OVERHD CLEAR OVERHD
CONTROLLER
DOOR WIDTH (mm)
(mm)
(mm)
(mm) WIDTH (mm)
(mm)DEPTH (mm)
(mm)
SPACE
(mm)
(mm)
(mm)
5'-7" (1702) 6'-7" (2007) 16'-11" (5156) 16'-11" (5156) 5'-7" (1702) 6'-7" (2007) 16'-11" (5156) 16'-11" (5156)
integral or remote cabinet
4'-4" (1321)
1'-8" (508)
4'-0" (1219)
5'-5" (1651) 6'-5" (1956) 16'-7" (5055) 16'-11" (5156) 5'-5" (1651) 6'-5" (1956) 16'-7" (5055) 16'-11" (5156)
adjacent or remote room
5'-0" (1524)
dimension (B)
3'-0" (914)
5'-5" (1651) 6'-5" (1956) 16'-10" (5131) 16'-11" (5156) 5'-5" (1651) 6'-5" (1956) 16'-10" (5131) 16'-11" (5156)
(1) S
maller pit and overhead dimensions may be available per specific applications. Contact your KONE Sales Professional
for further information.
(2) Buffer serviceCONTROL
platformsSPACE
are required
when pit depth exceeds 8'-6" (2590 mm).
(10)
(J)
(K)
(L)
(3) Hoist beams (by KONE) are required for installation (by others). Dimension H reflects clear under hoist beam.
Visit kone.us for the latest project-specific
CONTROLLER SPACE
WIDTH (mm)
DEPTH (mm)
DOOR WIDTH (mm)
CAPACITY LBS. (kg)
details, BIM Models, CAD drawings, (4) If occupied space exists below the hoistway, consult your KONE Sales Professional.
2000 to 4000
specifications, electrical data, reaction
Integral
or Remote
Cabinet
4'-4"
(1321)
1'-8"car
(508)
4'-0" (1219)
(5) All dimensions are(907
based
on an 8'-0" (2438
mm)
cab with
a 7'-0" (2134
mm)
door. Alternate
and door heights
are
to 1814)
loads and building access requirements.available, but may affect dimension H .
2000 to 4000
Dimension (B)
Adjacent or Remote Room
5'-0" (1524)
3'-0" (914)
(6) Add 8" (203 mm)(907
in non-seismic
and 12"
(305 mm) in seismic zones to
clear overhead dimension
H for front-only
to 1814)
passenger car if cab features glass-back wall.
Notes
(7) If an Emergency Battery Device (EBD) is required, please contact your KONE Sales Professional for further details
regarding dimensions J and L .
(1) Smaller pit and overhead dimensions (8)
mayContact
be available
(6)regarding
Add 8" (203
non-seismic
and
12" (305
in seismic
zones to
your per
localspecific
KONE applications.
Sales Professional
localmm)
codeinvariations
when
utilizing
themm)
integral
and remote
Contact your KONE Sales Professional forcloset
further
information.
clear overhead dimension (H) for front-only passenger car if cab features
options.
glass-back wall.
(2) Buffer service platforms are required when
depthKONE
exceeds
8'-6" (2590
(9) If pit
utilizing
Destination
or mm).
KONE Access™, contact your local KONE Sales Professional regarding control space
(7) If an Emergency Battery Device (EBD) is required, please contact your
size requirements.
(3) Hoist beams (by KONE) are required for installation
(by others). Dimension (H)
KONE Sales Professional for further details regarding dimensions (J) and (L).
reflects clear under hoist beam.
(4) If occupied space exists below the hoistway, consult your KONE Sales
Professional.
(8) Contact your local KONE Sales Professional regarding local code variations
when utilizing the integral and remote closet options.
(5) All dimensions are based on an 8'-0" (2438 mm) cab with a 7'-0" (2134 mm)
door. Alternate car and door heights are available, but may affect dimension (H).
(9) If utilizing KONE destination control system or KONE Access™, contact your
local KONE Sales Professional regarding control space size requirements.
Plan views
A
C
Plan Views
Section View
(A)
(C)
KONE MonoSpace 700 DX
Section view
(3)
(3)
(5) (6) H
D B
K (D) (B)
E
(5) (6)
(H)
F
(F)
G
(G)
L
J
(7)
TRAVEL
Integral Control Closet (standard)
G
(K)
(E)
(7)
(L)
(J)
(1) (2) I
J
(7)
(4)
Integrated Control Closet
K (standard)
TRAVEL
L
(G)
B
J
(7)
(7)
Remote Control Closet
(option 1)
(J)
(1) (2)
L
(K)
Adjacent or
Remote Control Room
(option 2)
(L)
(I)
I
(4)
(B)
(J)
(7)
Remote Control Closet
(option 1)
(L)
Adjacent or Remote
Control Room
(option 2)
Talk to a sales expert! Get the right
specifications and connect with a
KONE Sales Professional. Scan
this QR code or visit the link.
kone.us/700dxrear
KONE
kone.us
Copyright © 2022 KONE Inc. This publication is for general informational purposes only. KONE Inc. reserves the right to alter the product design and specifications without prior
notice. Minor differences between printed and actual colors may exist. KONE MonoSpace® DX and KONE Access™ are registered trademarks or trademarks of KONE Corporation.
SF2984 - Rev 0422
Printed in the U.S.
KONE MONOSPACE
DX DX
KONE
MONOSPACE700
700
®
®
MACHINE
MACHINE AT
AT SIDE
SIDE CONFIGUR
CONFIGUR ATION
ATION &
& DIMENSIONS
DIMENSIONS
Available in passenger and service shape with front and rear opening options
Max Travel 300 ft. (91.4 m)
Speed
200, 350, 500 fpm
(1.0, 1.78, 2.54 m/s)
Max Landings 36
CAPACITY
lbs. (kg)
A
Car Height (F)
8, 9 or 10 ft.
A SEISMIC
B 3048 mm)
B SEISMIC
(2438, 2743 or
OPENING HOISTWAY
HOISTWAY
HOISTWAY
TYPE
WIDTH (mm) WIDTH (mm) DEPTH (mm)
Entrance Height G
5000 (2268)
7, 8 or 9 ft.
5000 AIA (2268)
(2134, 2438 or
2500 (1134)
2743 mm)
SSP / CO
CO
2SP
2SP
2SP
2SP
SSP / CO
3000 (1361)
SSP / CO
3500 (1588)
SSP / CO
4000 (1814)
CO
SERVICE
9'-5"
(2870)
9'-9" (2972)
(2261)
2500
(1134)
SSP-CO
9'-5" (2870) 7'-5"
9'-9"
(2972)
3000
(1361)
SSP-CO
9'-5" (2870) 7'-5"
9'-9"
(2972)
10'-5"
(3175)
10'-9" (3277)
(2261)
3500 (1588)
SSP-CO
9'-5" (2870) 9'-9" (2972)
8'-5" (2565)
8'-9" (2667)
9'-5" (2870)
4000 (1814)
CO
10'-5" (3175) 10'-9" (3277)
8'-5" (2565)
8'-9" (2667)
9'-11" (3023)
4000 (1814)
2SP
8'-5" (2565) 8'-9" (2667)
8'-5" (2565)
8'-9" (2667)
10'-2" (3099)
4500 (2041)
2SP
8'-5" (2565) 8'-9" (2667)
8'-5"
(2565)
8'-9" (2667)
10'-7¾"
5000
(2268)
2SP
8'-5" (2565)
8'-9"(3245)
(2667)
5000 AIA (2268)
2SP
8'-5" (2565) 8'-9" (2667)
9'-5" (2870)
9'-9" (2972)
7'-1" (2159)
PASSENGER
SSP / CO
HOISTWAY
INTERIOR
INTERIOR
DOOR
DEPTH (mm) WIDTH (mm) DEPTH (mm) WIDTH (mm)
7'-1" (2159) 6'-8½" (2045) 4'-3¼" (1302) 3'-6" (1067)
SSP-CO
9'-5" (2870) 9'-9" (2972)
7'-1" (2159)
7'-4" (2235) 6'-8½" (2045) 4'-9¼" (1454) 3'-6" (1067)
SSP-CO
9'-5" (2870) 9'-9" (2972)
7'-5" (2261)
(A) SEISMIC
(B)
(B) SEISMIC 7'-8" (2337)(C) 6'-8½" (2045) 5'-5¼"
(D) (1657) 3'-6" (1067)
(E)
CO
10'-5" (3175) 10'-9" (3277)
7'-5" (2261)
7'-8" (2337) 7'-8½" (2350) 5'-5¼" (1657) 4'-0" (1219)
HOISTWAY
HOISTWAY
HOISTWAY
INTERIOR
INTERIOR
DOOR
2SP
8'-5" (2565) DEPTH
8'-9"(mm)
(2667)
9'-5"
(2870)
5'-8½" (1740)DEPTH
7'-6"
(2286)
4'-0"
(1219)
WIDTH (mm)
DEPTH
(mm) 9'-8" (2946)
WIDTH (mm)
(mm)
WIDTH
(mm)
2SP
8'-5" (2565) 8'-9" (2667) 9'-11" (3023)
10'-2" (3099) 5'-8½" (1740) 8'-0" (2438)
4'-0" (1219)
9'-9" (2972)
(2083)
7'-1"
(2159) 10'-5" 6'-8½"
4'-3¼"
(1302)
3'-6"
(1067)
(9)
2SP
8'-5" (2565)6'-10"
8'-9"
(2667) 10'-2"
(3099)
(3175) (2045)
5'-8½" (1740)
8'-7¾"
(2635) 4'-6"
(1372)
(9)
2SP
8'-5" (2565) 7'-1"
8'-9"
(2667) 10'-7¾"
(3321)(2045)
5'-8½" (1740)
9'-0"
(2743) 4'-6"
(1372)
9'-9" (2972)
(2159)
7'-4"(3245)
(2235) 10'-10¾"
6'-8½"
4'-9¼"
(1454)
3'-6"
(1067)
SERVICE
4500 (2041)
SSP / CO
Front & Reverse Opening
PASSENGER
SERVICE
F
Car Height
3500 (1588)
8, 9 or 10
ft.
4000 (1814)
(2438, 2743 or
4000 (1814)
3048 mm)
PASSENGER
FRONT & REVERSE OPENING
3000 (1361)
OPENING
TYPE†
3000 (1361)
3500 (1588)
(A)
4000 (1814)
HOISTWAY
4000
(1814)
WIDTH
(mm)
4500 (2041)
9'-5"
(2870)
5000
(2268)
5000(2870)
AIA (2268)
9'-5"
7'-8"
(2337)
7'-1"
(2159)
7'-6"
(2286)
7'-8"
(2337)
7'-9½" (2375)
9'-8" (2946)
7'-9½" (2375)
10'-2" (3099)
10'-1" (3073)
10'-5" (3175)
10'-7" (3226)
6'-8½" (2045)
5'-5¼"
(1657)
3'-6"(1067)
(1067)
7'-1" (2159)
6'-8½" (2045)
4'-3¾"
(1314) 3'-6"
7'-6" (2286)
6'-8½" (2045)
4'-9¾"
(1467) 3'-6"
7'-8½" (2350)
5'-5¼"
(1657)
4'-0"(1067)
(1219)
7'-9½" (2375) 6'-8½" (2045) 5'-5¾" (1670) 3'-6" (1067)
5'-8½" (1740)
7'-6" (2286)
4'-0" (1219)
7'-9½" (2375) 7'-8½" (2350) 5'-5¾" (1670) 4'-0" (1219)
5'-8½" (1740)
8'-0" (2438)
4'-0" (1219)
10'-1" (3073) 5'-8½" (1740) 7'-6½" (2299) 4'-0" (1219) (9)
5'-8½" (1740)
8'-7¾" (2635)
4'-6" (1372)
10'-7" (3226) 5'-8½" (1740) 8'-0½" (2451) 4'-0" (1219)
(9)(9)
10'-10¾"
(3321)
(2743)
4'-6"(1372)
(1372)
11'-2¾"
(3422)
11'-2¾"5'-8½"
(3422)(1740)
5'-8½" (1740)9'-0"
8'-8¼"
(2648) 4'-6"
11'-6¾" (3524) 11'-6¾" (3524) 5'-8½" (1740) 9'-0" (2743) 4'-6" (1372)(9)
7'-1" (2159)
6'-8½" (2045)
4'-3¾" (1314)
3'-6" (1067)
9'-5" (2870)
9'-9" (2972)
7'-6" (2286)
7'-6" (2286)
6'-8½" (2045)
4'-9¾" (1467)
3'-6" (1067)
9'-5" (2870)
9'-9" (2972)
7'-9½" (2375)
7'-9½" (2375)
6'-8½" (2045)
5'-5¾" (1670)
3'-6" (1067)
10'-5" (3175)
CAPACITY
lbs.(2565)
(kg)
8'-5"
10'-9" (3277)
PIT DEPTH
(mm)
8'-9"
(2667)
CLEAR
OVERHD
(mm)
10'-1" (3073)
7'-9½" (2375)
PIT DEPTH
(mm)(3073)
10'-1"
CLEAR
OVERHD
5'-8½"(mm)
(1740)
5'-5¾" (1670)
PIT DEPTH
(mm) (2299)
7'-6½"
CLEAR
OVERHD
4'-0"(mm)
(1219)
5'-11" (1803)
10'-7"(4140)
(3226)
13'-7"
13'-7"
(4140)
11'-2¾"
(3422)
13'-7" (4140)
11'-6¾" (3524)
13'-7" (4140)
14'-9" (4496)
15'-2" (4623)
10'-7"
(3226)
5'-5"
(1651)
5'-5"
(1651)
11'-2¾"
(3422)
5'-5" (1651)
11'-6¾" (3524)
5'-8" (1727)
5'-11" (1803)
5'-11" (1803)
5'-8½"
(1740)
13'-11"
(4242)
14'-4"
(4369)
5'-8½"
(1740)
14'-9" (4496)
5'-8½" (1740)
14'-11" (4547)
15'-3" (4648)
15'-11" (4551)
8'-0½"
(2451)
5'-5"
(1651)
5'-5"
(1651)
8'-8¼"
(2648)
5'-5" (1651)
9'-0" (2743)
7'-3" (2210)
7'-6" (2286)
—
4'-0"
(1219)
13'-11"
(4242)
14'-4"
(4369)
4'-6"
(1372)(9)
14'-9" (4496)
4'-6" (1372)(9)
15'-8" (4775)
16'-0" (4877)
—
CLEAR OVERHEAD H AND PIT DEPTH I
200 FPM (1.007'-9½"
M/S)(2375)
Visit kone.us
the latest 2SP
4000 for
(1814)
project-specific
details, BIM 2SP
4500 (2041)
8'-5"
8'-9" (1600)
(2667)
2500(2565)
(1134)
5'-3"
Models, CAD drawings,
3000(2565)
(1361)
5'-5"
5000 (2268)
2SP
8'-5"
8'-9" (1651)
(2667)
specifications, electrical data,
3500 (1588)
5'-5" (1651)
5000
AIA
(2268)
2SP
8'-5"
(2565)
8'-9"
(2667)
reaction loads and building
4000 (1814)
5'-8" (1727)
4500Opening
(2141)/ 2SP = Two
5'-8"
(1727)
requirements.
†access
SSP = Single
Speed Side Opening / CO = Single Speed Center
Speed
Side Opening
SERVICE
FRONT OPENING
Speed CAPACITY
LBS. (kg)
200, 350, 500 fpm
2500 (1134)
(1.00, 1.78, 2.54 m/s)
Front Opening
Max Landings
36
PASSENGER
Max Travel
Available
in passenger
and service2500
shape
front9'-5"
and
rear9'-9"
opening
options.
300 ft. (91.4
m)
(1134) with
SSP-CO
(2870)
(2972)
6'-10"
(2083)
Entrance Height (G)
7, 8 or 9 ft.
C
(2134, 2438Dor 2743 mm)E
5000 – 5000 AIA
(2268)
350 FPM (1.78 7'-8½"
M/S) (2350)
500 FPM (2.54 M/S)
4'-0" (1219)
CLEAR OVERHEAD (H) AND PIT DEPTH (I)
CAPACITY LBS. (kg)
(10)
CONTROL
SPACE
200 FPM (1.00
M/S)
J M/S)
350 FPM (1.78
2500 (1134)
CAPACITY
CONTROLLER
PIT DEPTH (mm) lbs. (kg) CLEAR OVERHD (mm) SPACE PIT DEPTH (mm)
2500 to 5000 AIA
integral or
(1134 to 2268)13'-7" (4140) remote cabinet
5'-3" (1600)
5'-5" (1651)
3000 (1361)
2500 to 5000 AIA
adjacent or
5'-5" (1651)
(1134 to 2268)13'-7" (4140) remote room5'-5" (1651)
K
WIDTH
(mm)
CLEAR OVERHD (mm)
4'-4"
(1321)(10)
13'-11" (4242)
5'-0"
(1524)14'-4" (4369)
L
500 FPM (2.54 M/S)
DEPTH
(mm)
PIT DEPTH (mm)
1'-8"
(508)(10)
5'-5" (1651)
dimension
(B) 5'-5" (1651)
DOOR WIDTH
(mm)OVERHD (mm)
CLEAR
4'-0"
(10)
(1219)
13'-11"
(4242)
3'-0"
(10) (4369)
14'-4"
(914)
3500 (1588)
5'-5" (1651)
13'-7" (4140)
5'-5" (1651)
14'-9" (4496)
5'-5" (1651)
14'-9" (4496)
4000 (1814)
5'-8" (1727)
13'-7" (4140)
5'-8" (1727)
14'-11" (4547)
7'-3" (2210)
15'-8" (4775)
4500 (2041)
further information.
5'-8" (1727)
14'-9" (4496)
5'-11" (1803)
15'-3" (4648)
7'-6" (2286)
16'-0" (4877)
—
—
5000 – 5000 AIA (2268)
Notes
(1) Smaller pit and overhead dimensions may be available per specific applications. Contact your KONE Sales Professional for
(2) B
uffer service platforms
are required when
pit depth exceeds 15'-11"
8'-6" (2590
mm).
5'-11" (1803)
15'-2" (4623)
5'-11" (1803)
(4851)
(3) A
hoist beam (by KONE) is required for installation (by others). Dimension H reflects clear under hoist beam.
(4) If occupied space exists below(10)
the hoistway, consult your KONE Sales Professional.
CONTROL SPACE
(J)
(K)
(L)
(5) A
ll dimensions are based on an 8'-0" (2438 mm) cab with a 7'-0" (2134 mm) door. Alternate car and door heights are
Visit kone.us for the latest project-specific
CONTROLLER SPACE
WIDTH (mm)
DEPTH (mm)
DOOR WIDTH (mm)
CAPACITY
(kg) H .
available, but will
affect LBS.
dimension
details, CAD drawings, BIM models, CSI
(6)
I
f
an
Emergency
Battery
Device
Professional
for
further
details
2500
to 5000
AIA (EBD) is required, please contact your KONE Sales
(10)
(10)
specifications, electrical data, reaction
Integral or Remote Cabinet
4'-4" (1321)
1'-8" (508)
4'-0" (1219)(10)
(1134 toJ 2268)
and L .
loads and building access requirements. regarding dimensions
2500
to 5000
AIAProfessional regarding local code variations when utilizing the integral and remote
(7) C
ontact your local
KONE
Sales
Dimension (B)
Adjacent or Remote Room
5'-0" (1524)
3'-0" (914)(10)
(1134 to 2268)
closet options.
Notes
(8) If utilizing KONE Destination or KONE Access™, contact your local KONE Sales Professional regarding control space
(1) Smaller pit and overhead dimensions may
berequirements.
available per specific applications.
(6) If an Emergency Battery Device (EBD) is required, please contact your KONE
size
Contact your KONE Sales Professional for further information.
Sales Professional for further details regarding dimensions (J) and (L).
(9) 4'-0" (1219 mm) door width also available.
(2) Buffer service platforms are required when pit depth exceeds 8'-6" (2590 mm).
(7) Contact your local KONE Sales Professional regarding local code variations
(10)
If IBC 2018
ASME A17.1-2019/CSA
B44-19when
code is
applicable,
contactand
your
local sales
utilizing
the integral
remote
closetprofessional
options. for controller
(3) A hoist beam (by KONE) is required for
installation
(byorothers).
Dimension (H)
space configurations.
reflects clear under hoist beam.
(8) If utilizing KONE destination control system or KONE Access™, contact your
local KONE Sales Professional regarding control space size requirements.
(4) If occupied space exists below the hoistway, consult your KONE Sales
Professional.
(9) 4’-0” (1219 mm) door width also available.
(5) All dimensions are based on an 8'-0" (2438 mm) cab with a 7'-0" (2134 mm)
(10) If IBC 2018 or ASME A17.1-2019/CSA B44-19 code is applicable, contact your
door. Alternate car and door heights are available, but will affect dimension (H).
local sales professional for controller space configurations.
Plan views
A
C
Plan Views
E
KONE MonoSpace 700 DX
Section view
(3)
Section View
(A)
(C)
(E)
(1) (5) H
D B
K
E
F
G
(3)
(D) (B)
L
J
(1) (5)
(6)
Integral Control Closet (standard)
(H)
(F)
G
(1) (2)
I
(K)
(E)
(L)
(J)
(6)
J
(6) Integrated Control Closet
(4)
(standard)
K
(K)
L
J
(L)
(6)
(J)
(G)
TRAVEL
B
Remote Control Closet
(6)
(option 1) Remote Control Closet
TRAVEL
(option 1)
L
(6)
(J)
(G)
Adjacent or
Remote Control Room
(option 2)
(1) (2)
(I)
I
Adjacent or Remote
Control Room (option 2)
(4)
(B)
(L)
For configuration guidance or more information
scan this code or visit our website to get in touch
with a KONE Sales Professional:
kone.us/ms700dx
KONE
kone.us
Copyright © 2022 KONE Inc. This publication is for general informational purposes only. KONE Inc. reserves the right to alter the product design and specifications without prior
notice. Minor differences between printed and actual colors may exist. KONE MonoSpace® DX and KONE Access™ are registered trademarks or trademarks of KONE Corporation.
SF2983 - Rev 0422
Printed in the U.S.
KONE MINISPACE
KONE
MINISPACEDXDX
™
™
CONFIGUR ATIONS & DIMENSIONS
CONFIGUR ATIONS & DIMENSIONS
Max Travel
63
D
E
Clear Overhead I
2000 (907)
and Pit Depth J
PASSENGER
6'-8" (2032)
6'-81⁄2 " (2045)
4'-31⁄4 " (1302)
3'-6" (1067)
3000 (1361)
SSP-CO
8'-4" (2540)
8'-8" (2642)
7'-2" (2184)
6'-81⁄2 " (2045)
4'-91⁄4 " (1454)
3'-6" (1067)
3500 (1588)(A)
SSP-CO
8'-4"
(2540)
(A) SEISMIC
8'-8" (2642)
(B)
7'-10" (2388)
(C)6'-8 ⁄ " (2045)
1
5'-5(D)
⁄4 " (1657)
3'-6" (1067)
(E)
4000 (1814)
CO
OPENING
HOISTWAY
4000 (1814)
TYPE†
WIDTH (mm) 2SP
4500 (2041)
2SP
SSP
7'-4" (2235)
5000 (2268)
2SP
SSP / CO
8'-4" (2540)
5000 AIA (2268)
2SP
SSP / CO
8'-4" (2540)
2000 (907)
SSP
SSP / CO 2500 (1134)
8'-4" (2540)
SSP-CO
9'-4" (2845)
HOISTWAY
8'-1"
WIDTH(2464)
(mm)
8'-1" (2464)
7'-8" (2337)
8'-1" (2464)
8'-8" (2642)
8'-8" (2642)
8'-8" (2642)
8'-4" (2540)
8'-8"
9'-4" (2642)
(2845)
9'-8" (2946)
7'-10" (2388)
7'-81⁄2 " (2350)
HOISTWAY
INTERIOR
8'-4" (2540)
DEPTH (mm) 9'-2" (2794)WIDTH 5'-8
(mm)1⁄2 " (1740)
8'-4" (2540)
9'-8" (2946)
5'-81⁄2 " (1740)
6'-10" (2083)
5'-8½" (1740)
8'-4" (2540)
10'-2" (3099)
5'-81⁄2 " (1740)
6'-8" (2032)
6'-8½" (2045)
8'-11" (2718) 10'-73 ⁄4 " (3245) 5'-81⁄2 " (1740)
7'-2" (2184) 1
6'-8½" (2045)
8'-8" (2642)
6'-3 ⁄4 " (1911)
5'-8 1⁄2 " (1740)
1
6'-8½" 6'-8
(2045)
9'-8" 7'-10"
(2946)(2388)
6'-3 1⁄4 " (1911)
⁄2 " (2045)
5'-51⁄4 " (1657)
INTERIOR
7'-6"(mm)
(2286)
DEPTH
SERVICE
8'-8" (2642)
Front Opening
SERVICE
5000 AIA (2268)
4
8'-4" (2540)
PASSENGER
4000 (1814)
Entrance Height G
4000 (1814)
7, 8 or 9 ft.
4500 (2041)
(2134, 2438 or
5000 (2268)
2743 mm)
1
2
SSP-CO
Front & Reverse Opening
PASSENGER
C
2500 (1134)
1
2
8'-0" (2438)
4'-3¼" (1302)
8'-73 ⁄4 " (2635)
4'-3¼" (1302)
9'-0" (2743)
4'-9¼"3 (1454)
4'-3 ⁄4 " (1314)
5'-5¼"
4'-33 ⁄(1657)
4 " (1314)
4'-0" (1219)
DOOR
4'-0"
(1219)
WIDTH
(mm)
4'-0" (1219)
3'-0" (914)
4'-6" (1372)(9)
3'-6" (1067)
4'-6" (1372)(9)
3'-6" (1067)
3'-0" (914)
3'-6"
(1067)
3'-6"
(1067)
CO
9'-4" (2845)
3000 (1361)
SSP-CO
9'-8"
9'-4" (2946)
(2845)
1
7'-8½" 6'-8
(2350)
9'-8" 7'-10"
(2946)(2388)
6'-9 1⁄4 " (2064)
⁄2 " (2045) 5'-5¼"
4'-93 ⁄(1657)
4 " (1467)
4'-0"
(1219)
3'-6"
(1067)
2SP
3500 (1588)
SSP-CO
8'-1" (2464)
4000 (1814)
CO
8'-1" (2464)
4000 (1814)
2SP
8'-1" (2464)
4500 (2041)
2SP
8'-8" (2642)
5000 (2268)
2SP
(2540) 2SP
5000 AIA8'-4"
(2268)
9'-4" (2540)
(2845)
8'-4"
10'-4" (3150)
8'-4" (2540)
8'-1" (2464)
8'-4" (2540)
8'-1" (2464)
8'-11" (2718)
8'-1" (2464)
8'-8" (2642)
(2642)
1
1
3
9'-8" (2946)
⁄2 " (2045) 7'-6"
5'-5(2286)
⁄4 " (1670)
9'-2" (2794)7'-5 ⁄4 " (2267)
5'-8½" 6'-8
(1740)
10'-8" (3251)
7'-5 1⁄4 " (2267)
7'-8 1⁄2 " (2350)
5'-53 ⁄4 " (1670)
9'-8" (2946)
5'-8½" (1740)
8'-0" (2438)
8'-4" (2540)
10'-1" (3073)
5'-8 1⁄2 " (1740)
7'-6 1⁄2 " (2299)
10'-2" (3099)
5'-8½" (1740)
8'-7¾"1 (2635)
8'-4" (2540)
10'-7" (3226)
5'-8 1⁄2 " (1740)
8'-0 ⁄2 " (2451)
10'-7¾" (3245) 3
5'-8½" (1740)
9'-0" (2743)
8'-4" (2540)
11'-2 ⁄4 " (3423) 5'-8 1⁄2 " (1740)
8'-81 ⁄4 " (2648)
1
5'-8½" 5'-8
(1740)
9'-0" 6'-3¼"
(2743)(1911)
11'-63 ⁄4 " (3524)
⁄2 " (1740) 4'-3¾"
9'-0"(1314)
(2743)
3'-6"
(1067)
4'-0"
(1219)
4'-0" (1219)
4'-0" (1219)
4'-0" (1219) (9)
4'-6" (1372)
4'-0" (1219)
(9)
4'-6" (1372)
4'-6" (1372)(9)
(9)
(914)
4'-6"3'-0"
(1372)
2SP
2SP
SERVICE
2000 (907)
F (1134)
Car Height2500
8, 9 or 10 ft.
3000 (1361)
(2438, 2743 or
3500 (1588)
3048 mm)
PASSENGER
B
1
Speed
200, 350, 400,
500, 700, 1000 fpm
CAPACITY
(1.00, 1.78, 2.00,
LBS. (kg)
2.54, 3.56, 5.00 m/s)
FRONT OPENING
SEISMIC
Speed
(F)
Height (G)INTERIOR ClearDOOR
Overhead (I)
CAPACITY
OPENING
HOISTWAYCar Height
HOISTWAY
HOISTWAY Entrance
INTERIOR
lbs. (kg)
WIDTH (mm)
WIDTH
(mm)
DEPTH (mm) and
WIDTH
(mm) (J)
200, 350, 400,
500, 700,TYPE
1000 fpm
8, 9 or
10 ft.(mm) DEPTH (mm) 7, 8WIDTH
or 9 ft.
Pit Depth
2000
(907)
SSP
7'-4"
(2235)
7'-8"
(2337)
6'-10"
(2083)
5'-8
⁄
"
(1740)
4'-3
⁄
"
(1302)
3'-0"
(914)
(1.00, 1.78, 2.00, 2.54, 3.56, 5.00 m/s) (2438, 2743 or 3048 mm) (2134, 2438 or 2743 mm)
Landings
MaxMax
Landings
63
FRONT & REVERSE OPENING
A
A
ft. (180 m)
Max590
Travel
590 ft. (180 m)
2SP
SSP
2500 (1134)
SSP / CO
9'-4" (2845)
9'-8" (2946)
6'-3¼" (1911)
6'-8½" (2045)
4'-3¾" (1314)
3'-6" (1067)
3000 (1361)
SSP / CO
9'-4" (2845)
9'-8" (2946)
6'-9¼" (2064)
6'-8½" (2045)
4'-9¾" (1467)
3'-6" (1067)
3500 (1588)
SSP / CO
9'-4" (2845)
9'-8" (2946)
10'-4" (3150)
PIT
DEPTH
8'-1"(mm)
(2464)
2SP 2000
8'-1" (2464)
–
(907)
–
2SP
8'-1" (2464)
2500-3500
5'-3"
2SP
8'-8"
(2642)
(1134-1588)
(1600)
10'-8" (3251)
CLEAR
PIT
OVERHD
DEPTH
(mm) 8'-4" (2540)
(mm)
8'-4" (2540)
–
–
–
–
8'-4" (2540)
14'-1"
5'-6"
9'-0"
(2743)
(4292)
(1676)
CLEAR OVERHEAD I AND PIT DEPTH J
CO
CAPACITY
2SP lbs. (kg)
SERVICE
4000 (1814)
Visit kone.us for
the latest
project-specific
details,
BIM
4000
(1814)
models, CAD 4500
drawings,
(2041)
specifications, electrical data,
5000 (2268)
reaction loads and building
5000 AIA (2268)
access requirements.
200 FPM
1.00 m/s
350 FPM
400 FPM
7'-5¼" (2267)
6'-8½" (2045)
1.78 m/s
2.03 m/s
14'-1"
† SSP = Single Speed Side Opening / CO = Single Speed 4000
Center Opening /5-'3"
2SP = Two Speed
Side Opening 5'-6"
(1814)
(1600)
(4292)
(1676)
4500
CLEAR OVERHEAD (I) AND PIT DEPTH (J)
(2041)
5000
CAPACITY LBS. (kg)
2000 (907)
2500-3500 (1134-1588)
200 FPM (1.00
M/S)
(2268)
PIT DEPTH
(mm)
—
5-'3"
(1600)
14'-7"
(4445)
5'-6"
(1676)
5-'3"
14'-7"
5'-6"
(1.78 M/S)(1676)
(1600)350 FPM
(4445)
5000 AIA
5'-6"
14'-9"
5'-8"
CLEAR
OVERHD (1676)
PIT DEPTH (4496)
CLEAR OVERHD
(2268)
(1727)
(mm)
(mm)
(mm)
—
Notes
—
—
7'-5¼" (2267)
CLEAR
PIT
OVERHD
DEPTH
10'-1" (3073)
(mm)
(mm)
– 10'-7" (3226)
–
–
–
11'-2¾" (3423)
14'-7"
6'-0"
11'-6¾"
(3524)
(4445)
(1829)
500 FPM
700 FPM (1,2,3)
5'-5¾" (1670)
3'-6" (1067)
2.54 m/s
3.56 m/s (1,2,3)
7'-8½" (2350)
CLEAR
PIT
OVERHD
DEPTH
5'-8½"
(mm) (1740)
(mm)
5'-8½"
(1740) –
–
–
–
5'-8½" (1740)
14'-11"
6'-10"
5'-8½"
(1740)
(4547)
(2083)
5'-5¾" (1670)
CLEAR
OVERHD
7'-6½"
(mm)(2299)
8'-0½"
– (2451)
–
8'-8¼" (2648)
15'-8"
9'-0"
(2743)
(4775)
4'-0" (1219)
CLEAR
OVERHD
4'-0"(mm)
(1219)
4'-0"21'-0"
(1219)
10'-6"
(3200)
(6401)
4'-6" (1372)(9)
10'-6"
21'-0" (9)
(1372)
(3200) 4'-6"(6401)
PIT
DEPTH
(mm)
14'-7"
(4445)
6'-0"
(1829)
14'-11"
(4547)
6'-10"
(2083)
15'-8"
(4775)
–
–
–
–
15'-1"
(4597)
6'-0"
(1829)
15'-5"
(4953)
6'-10"
(2083)
16'-2"
(4928)
–
–
–
–
15'-1"
6'-0"
400
FPM (2.03
M/S)
(4597)
(1829)
15'-1"
PIT(4597)
DEPTH
(mm)
—
15'-5"
6'-10"
16'-2"
(2.54 M/S)
(4953) 500 FPM
(2083)
(4928)
7'-2"
16'-2"
7'-2"
16'-2"
CLEAR
OVERHD (4928)
PIT DEPTH(2184)
CLEAR OVERHD
(2184)
(4928)
(mm)
(mm)
(mm)
—
—
—
–700 FPM (1,2,3)
–
–
–
3.56
m/s (1,2,3)
–
PIT DEPTH
–
(mm)
–
CLEAR
– OVERHD
(mm)
10'-6" (3200)
21'-0" (6401)
5'-3" (1600)(1) 14'-1"
(4292) above
5'-6"1000
(1676)fpm14'-7"
(4547)
6'-10" (2083)
15'-8" Sales
(4775)Professional
10'-6" (3200)
21'-0" (6401)
For speeds
(5.00(4445)
m/s) or 6'-0"
travel(1829)
above 14'-11"
590' (180
m) contact
your KONE
for design
and planning
assistance.
14'-1"
(4292)
5'-6" (1676)
4000 (1814)
5'-3" (1600)
4500 (2041)
(2)For 700 fpm (3.56 m/s) and 1000 fpm (5.00 m/s) front front opening passenger configurations add 2" (51 mm) to the
5'-3" (1600)
14'-7" (4445)
5'-6" (1676)
15'-1" (4597)
6'-0" (1829)
15'-5" (4953) 6'-10" (2083) 16'-2" (4928)
—
—
hoistway depth B .
5000 (2268)
5'-3" (1600)(3) 14'-7"
(4445) is based
5'-6" (1676)
15'-1"
(4597)
6'-0"For
(1829)
15'-5" (4953) applications,
6'-10" (2083) please
16'-2" (4928)
—
Information
upon chain
compensation.
rope compensation
consult your KONE
Sales
5000 AIA (2268)
5'-6" (1676)
Professional.
14'-9"
(4496)
5'-8" (1727)
14'-7" (4445)
15'-1" (4597)
6'-0" (1829)
7'-2" (2184)
14'-11" (4547)
16'-2" (4928)
6'-10" (2083)
7'-2" (2184)
15'-8" (4775)
16'-2" (4928)
—
—
—
—
—
(4) All dimensions are based on an 8'-0" (2,438 mm) cab with a 7'-0" (2,134 mm) door. Alternate car and door heights are
available, but will affect dimension I .
Visit kone.us for the latest project-specific details, BIM models, CAD drawings,
(5) If occupied space exists below the hoistway, consult your KONE Sales Professional.
specifications, electrical data, reaction loads and building access requirements.
(6) Information is based upon structural machine room floor slabs. For machine beam applications, please consult your KONE
Sales Professional.
Notes
(7) Machine room height of 8'-0" (2,438 mm) is measured from the machine room floor surface to underside of the lowest
(1) For speeds above 1000 fpm (5.00 m/s)
or travel above
(180 m) contact
(6) Information
based uponfor
structural
obstruction
above 590'
the machine
KONE SalesisProfessional
details.machine room floor slabs. For machine
H . Consult yourbeam
your KONE Sales Professional for design and planning assistance.
applications, please consult your KONE Sales Professional.
For(5.00
service
applications
the machine
room is not
the hoistway
requires
additional
7" (178from
mm)the
of width.
(2) For 700 fpm (3.56 m/s) and 1000(8)
fpm
m/s)
front opening
passenger
(7) centered
Machineonroom
height ofand
8'-0"
(2,438anmm)
is measured
machine
additional
7" (178
counterweight
side.
Consult your
Salesobstruction
Professional above
for details.
configurations add 2" (51 mm) to theThe
hoistway
depth
(B). mm) should be added to the
room
floor surface
to underside
of KONE
the lowest
the
machine (H). Consult your KONE Sales Professional for details.
(3) Information is based upon chain compensation.
rope
compensation
(9) 4’-0” (1219For
mm)
door
width also available.
applications, please consult your KONE Sales Professional.
(8) For service applications the machine room is not centered on the hoistway
and requires an additional 7" (178 mm) of width. The additional 7" (178
(4) All dimensions are based on an 8'-0" (2,438 mm) cab with a 7'-0" (2,134 mm)
mm) should be added to the counterweight side. Consult your KONE Sales
door. Alternate car and door heights are available, but will affect dimension (I).
Professional for details.
(5) If occupied space exists below the hoistway, consult your KONE Sales
(9) 4’-0” (1219 mm) door width also available.
Professional.
Plan Views
Section view
H
KONE MiniSpace DX
Section View
E
Plan views
(8)
(2) B
(E)
D
(H) (8)
I
(4)
F
(2)
G
(B) (D)
E
C
A
(6)
(G) (F)
(I) (4)
Machine Room
(E)
(C)
(A)
TRAVEL
(6)
G
Machine Room
B
J
(G)
TRAVEL
(B)
(5)
A
(9)
(J)
(5)
(A)
(8)
For configuration guidance or more information
scan this code or visit our website to get in touch
with a KONE Sales Professional:
kone.us/minisdx
KONE
kone.us
Copyright © 2022 KONE Inc. This publication is for general informational purposes only. KONE Inc. reserves the right to alter the product design and specifications without prior
notice. Minor differences between printed and actual colors may exist. KONE MiniSpace™ DX is a trademark of KONE Corporation.
SF2985 - Rev 0422
Printed in the U.S.
AN INTRODUCTION TO
ESCALATORS AND AUTOWALKS
Definitions and components
An escalator is a moving staircase for transporting people between floors of a building. It is generally agreed that
an escalator is the most efficient means to move large numbers of people between floors.
Item Component
Item Component
1
Handrail
11
Transition radii
2
Skirting
12
Truss
3
Steps/pallets
13
Side cladding
4
Decking
14
Step chain
6
5
Balustrade
15
Tracks
2
6
Horizontal steps/pallets
16
Return station
4
7
Drive station
17
Access cover plate
5
8
Controller
18
Newel
9
Front plate
10
Handrail drive
1
18
9
17
7
8
13
16
14
3
11
10
15
12
A horizontal autowalk is a conveyor belt that transports people horizontally. Autowalks are generally provided in areas
where people need to walk long distances with luggage, baggage carts or shopping carts. An autowalk is generally flat,
but can be slightly inclined.
1
5
4
9
16
18
14
17
12
7
15
2
8
3
10
KONE ESCALATORS AND AUTOWALKS
n
Quiet, smooth operation
n
Eco-efficient and economical
n
Small installation dimensions
n
High levels of reliability
n
Design options to match the image
of your building
KONE TransitMaster™ 210
ApplicationSupermarkets, department stores, shopping centers
Type
Escalator
Rise
Up to 52' 5" (16 m)
Nominal Step Width 24", 32", 40" (600, 800, 1000 mm)
Balustrade
Glass or solid
Speed
100 fpm (.50 m/s)
The KONE TransitMaster 210 is a commercial escalator
targeted primarily toward the retail segment –
supermarkets, department stores and shopping
centers. It is designed, from both a technical and
visual point of view, to fulfill customer requirements
in various target segments.
KONE TransitMaster™ 220
Application​Stadiums, Arenas, Convention Centers, Airports,
Light Rail
Type
Escalator
Rise
Up to 49' 2" (15 m)
Nominal Step Width 24", 32", 40" (600, 800, 1000 mm)
Balustrade
Glass or Solid
Speed
100 fpm (0.5 m/s)
The KONE TransitMaster 220 is a heavy-duty escalator
targeted primarily towards the Infrastructure segment,
and in particular mid to high duty applications. This
segment covers airports, rail and transportation systems
as well as other transit centers. Airports and rail systems
are the most common target buildings for this solution.
KONE TransitMaster™ 180
ApplicationHeavy traffic, public transportation, metro
Type
Escalator
Nominal Step Width 24", 32", 40" (600, 800, 1000 mm)
Balustrade
Glass or solid
Speed
100 fpm (.50 m/s)
The versatile KONE TransitMaster 180 escalator is ideal for
new installations and is specifically designed to meet the
demanding needs of public transportation all the way up to
the demanding requirements of mass transit airport and
railway systems. Our heavy-duty escalators are designed to
enable the seamless flow of large numbers of passengers.
KONE TransitMaster™ 165/185
ApplicationHeavy traffic, airports, public transportation, metro
Type
Autowalk
Length
Per requirements
Nominal Pallet Width32", 40", 48", 56" (800, 1000, 1200, 1400 mm)
Balustrade
Glass or solid
Speed
100 or 130 fpm (.50 or .66 m/s)
The KONE Autowalk achieves the perfect balance
between form and function. An attractive welcome area
invites passengers to take an uncommonly smooth and
quiet ride, while offering options to meet your
architectural vision.
KONE EcoMod®
ApplicationRetail, airports, stadiums, hotels, leisure venues
Type
Complete escalator modernization
Nominal Step Width 24", 32", 40" (600, 800, 1000 mm)
Balustrade
Glass or solid
Speed
100 fpm (.50 m/s)
For the latest product information and interactive design tools, visit kone.us
The KONE EcoMod escalator modernization solution
offers an innovative and systematic approach to
replacing the entire workings of your escalators and
delivering brand new technology without expensive,
disruptive truss removal.
KONE TRANSITMASTER 210
™
Commercial Escalator Product
With over 100 years of experience in the elevator and escalator industry, KONE is your trusted partner, dedicated to
ensuring smooth People Flow™. KONE’s reliable escalator solutions use proven technology and is designed to meet the
needs of demanding commercial environments, such as supermarkets, department stores and shopping centers. It is
also suitable for hotels, offices, hospitals, leisure facilities and airports.
The main benefits of the
TransitMaster 210
Main Characteristics of the TransitMaster 210
​​Market Segment
Maximum rise
n
n
n
Attractive design helps to create a
pleasant ambiance in the building
All visual options can be customized to
fit the customers overall building design
Harmonized look and feel
across the product portfolio
n
n
LED lighting solutions support
increase passenger safety
Serves the customers building
throughout its entire lifecycle
Smart Technology: KONE 24/7
Connected Services.
up to 52' 2" (16 m)
Inclination
30°
Transition radii
Lower Radius: 1.0 or 2.0 (m) Upper Radius: 1.0, 1.5, 2.7 (m)
Speed
100 fpm (0.5 m/s)
Step width
24", 32", 40" (600, 800, 1000 mm)
​Step load
192 lbs. / step​
Horizontal steps
​Handrail Type
Balustrade type
n
Retail, Office, Medical, Small Airports
​Balustrade glass thickness
Balustrade height
2/2 or 3/3
C-Type
Glass, Solid stainless steel inclined
3/8" (10mm) and 1/2" (12mm)
40" (1000 mm)
​Skirt material
Black teflon
Front plate material
Black plastic
Environment
Indoor / Outdoor
L​ oad profile
Overall load profile 42%
12h/day; 7 days/week:
2% time at 100% load
35% time at 50% load
63% time at 25% load
KONE TransitMaster 210
Configuration & Dimensions
KONE TRANSITMASTER 210 BASIC DATA
Inclination
Level
Steps
Radii
Maximum
Vertical Rise
Nominal
Step Width
Balustrade
Balustrade
height
Speed
Electrification
Chain
Type
Handrail
Environment
30 degrees
2 or 3
Level
Steps
Lower Radius:
1.0 or 2.0
(meters)
Upper Radius:
1.0, 1.5, 2.7
(meters)
52' 5"
(16 m)
24", 32"
and 40"
(600,800,
1000 mm)
Glass and
solid
incline
3'-3' 3⁄8"
(1000 mm)
100 FPM
(0.5 m/s)
NFPA 70 and
CSA-C22.1
Inside
Chain
Roller
C-Type
Indoor/
Outdoor
DIMENSION BB/EE (UPPER HEAD) FOR NON-SEISMIC
BB
W1: Step Width
H: Rise
Level steps - up radius / low radius (m)
EE
2-1.0/1.0
2-1.5/1.0
3-1.5/1.0
3-2.7/2.0
8' 2 ⁄16" - 15' 9"
(2500 mm - 4800 mm)
8' ⁄8"
(2455 mm)
8' 5 ⁄16"
(2589 mm)
9' 8 ⁄8"
(2949 mm)
10' 4 15⁄16"
(3173 mm)
1' 9 1⁄16"
(535 mm)
15' 9" - 31' 9 7⁄8"
(4801 mm - 9700 mm)
8' 3 7⁄16"
(2525 mm)
8' 8 11⁄16"
(2659 mm)
9' 10 7⁄8"
(3019 mm)
10' 4 15⁄16"
(3243 mm)
1' 11 13⁄16"
(605 mm)
31' 9 15⁄16" - 52' 5 15⁄16"
(9701 mm - 16000 mm)
9' 8 5⁄16"
(2955 mm)
10' 1 5⁄8"
(3089 mm)
11' 3 13⁄16"
(3449 mm)
12' 5⁄8"
(3673 mm)
3' 4 3⁄4"
(1035 mm)
32"
(800 mm)
8' 2 7⁄16" - 34' 5 3⁄8"
(2500 mm - 10500 mm)
8' 7 3⁄8"
(2625 mm)
9' 5⁄8"
(2759 mm)
10' 2 13⁄16"
(3119 mm)
10' 11 5⁄8"
(3343 mm)
2' 3 3⁄4"
(705 mm)
24"
(600 mm)
8' 2 7⁄16" - 39' 4 7⁄16"
(2500 mm - 12000 mm)
9' 8 5⁄16"
(2955 mm)
10' 1 5⁄8"
(3089 mm)
11' 3 13⁄16"
(3449 mm)
12' 5⁄8"
(3673 mm)
3' 4 3⁄4"
(1035 mm)
7
40"
(1000 mm)
5
15
1
DIMENSION AA/DD (LOWER HEAD) FOR NON-SEISMIC
AA
W1: Step Width
Truss/comb
heating
Level steps - up radius / low radius (m)
DD
2-1.0/1.0
2-1.5/1.0
3-1.5/1.0
3-2.7/2.0
40"
(1000 mm)
Without/With
7' 3 5⁄8" (2226 mm)
7' 3 5⁄8" (2226 mm)
8' 3 3⁄4" (2534 mm)
9' 1 5⁄16" (2777 mm)
1' 9 1⁄16" (535 mm)
32"/24"
(800 mm / 600 mm)
Without
7' 3 5⁄8" (2226 mm)
7' 3 5⁄8" (2226 mm)
8' 3 3⁄4 " (2534 mm)
9' 1 5⁄16" (2777 mm)
1' 9 1⁄16" (535 mm)
32"/24"
(800 mm / 600 mm)
With
8' 5 7⁄16" (2576 mm)
8' 5 7⁄16" (2576 mm)
9' 5 9⁄16" (2884 mm)
10' 3 1⁄8" (3127 mm)
2' 10 13⁄16" (885 mm)
HA
HB
CC
FF
HL
HU
3' 3" (990 mm)
3’ 1” (940 mm)
1.73205 x H
AA+7' 1⁄2'
(AA+2139 mm)
3' 8 1⁄2" (1130 mm)
3' 8 1⁄2" (1130 mm)
KONE TransitMaster 210
Configuration & Dimensions
R
KEY WIDTH DIMENSIONS
W1: Step width
3'-3' 1⁄2" (1000 mm)
2' - 7' 1⁄2" (800 mm)
1'-11' 1⁄2" (600 mm)
W2: Handrail centerline distance
4'-1' 11⁄16" (1262 mm)
3'-5 7⁄8" (1064 mm)
2'-10' 1⁄8" (866 mm)
W4: Width of truss
4'-11' 7⁄16 (1510 mm)
4' - 3' 5⁄8 (1312 mm)
3' - 7' 7⁄8" (1114 mm)
W5: Width of finished escalator
5'- 3' 1⁄16" (1602 mm)
4' - 7' 1⁄4" (1404 mm)
3'-11' 1⁄2" (1206 mm)
W6: Width of pit
5'- 5' 1⁄16" (1650 mm)
4' - 9' 3⁄16" (1450 mm)
4' - 1' 5⁄16" (1250 mm)
EXTENSION BY SEISMIC TYPE
Seismic end
support type
Increase for
AA&BB&DD&EE
Type A
0' 1 3⁄4" (45 mm)
Type B
0' 1 3⁄4" (45 mm)
Type C
0' 3 1⁄8" (79 mm)
Type D
0' 4 1⁄16" (103 mm)
Type E
0' 5 5⁄8" (146 mm)
Type F
0' 8 1⁄16" (205 mm)
Type G
0' 10 5⁄16" (262 mm)
Type H
1' 5⁄16" (313 mm)
Notes
(1) Details represent standard KONE escalator
configurations. Please consult your sales
R
professional to review all possible deviations.
Visit KONE.us for the latest project-specific details,
electrical data, reaction loads, planner tools and
building access requirements.
*All drawings are for illustration purposes only.
KONE TRANSITMASTER 220
™
Public Transportation Escalator Product
With over 100 years of experience in the elevator and escalator industry, KONE is your trusted partner, dedicated to
ensuring smooth People Flow™. KONE’s reliable escalator solutions use proven technology and is designed to meet the
needs of demanding public transportation environments, such as airports, rail and transportation systems as well as
other transit centers.
The main benefits of the
TransitMaster 220
Main Characteristics of the TransitMaster 220
​​Market Segment
Maximum rise
n
n
n
Extensive and flexible offering to
match any need and environment
Unconditional safety and reliability
even under heavy People Flow
Optimized total cost of ownership
to meet the needs of the customer
n
n
Optional features to offer
environmentally friendly operation
Elegant and modern design with
numerous lighting options
Smart Technology: KONE 24/7
Connected Services.
up to 49' 2" (15 m)
Inclination
30°
Transition radii
Lower Radius: 1.5/1.0 (m) Upper Radius: 2.7/2.0 (m)
Speed
100 fpm (0.5 m/s)
Step width
24", 32", 40" (600, 800, 1000 mm)
​Step load
264 lbs. / step​
Step chain
Inside roller (75 mm x 23.5 mm)
Horizontal steps
​Handrail Type
n
Stadiums, Arenas, Convention Centers, Airports, Light Rail
Balustrade type
​Balustrade glass thickness
Balustrade height
​Skirt material
Front plate material
2/2 or 3/3
V-Type
Glass, Solid inclined balustrade
3/8" (10 mm) and 1/2" (12 mm)
40" (1000 mm)
Stainless Steel
Stainless Steel
Environment
Indoor / Outdoor
L​ oad profile
Overall load profile 54%
20h/day; 7 days/week
10% time at 100% load
40% time at 50% load
50% time at 25% load
KONE TransitMaster 220
Configuration & Dimensions
KONE TRANSITMASTER 210 BASIC DATA
Inclination
Level
Steps
Radii
Maximum
Vertical Rise
Nominal
Step Width
Balustrade
Balustrade
height
Speed
Electrification
Chain
Type
Handrail
Environment
30 degrees
2 or 3
Level
Steps
Lower Radius:
1.5/1.0
(meters)
Upper Radius:
2.7/2.0
(meters)
49' 2"
(15 m)
24", 32"
and 40"
(600,800,
1000 mm)
Glass and
solid
incline
3'-3' 3⁄8"
(1000 mm)
100 FPM
(0.5 m/s)
NFPA 70 and
CSA-C22.1
Inside
Chain
Roller
V-Type
Indoor/
Outdoor
DIMENSION BB/EE (UPPER HEAD) FOR NON-SEISMIC
BB
W1: Step Width
H: Rise
Level steps - up radius / low radius (m)
EE
2-1.0/1.0
2-1.5/1.0
3-1.5/1.0
3-2.7/2.0
8' 2 ⁄16"- 11' 9 ⁄4"
(2500 mm - 3600 mm)
5
8' ⁄8"
(2455 mm)
8' 5 ⁄16"
(2589 mm)
9' 8 ⁄8"
(2949 mm)
10' 4 15⁄16"
(3173 mm)
1' 9 1⁄16"
(535 mm)
11' 9 3⁄4" - 23' 11 3⁄8"
(3601 mm - 7300 mm)
8' 3 7⁄16"
(2525 mm)
8' 8 11⁄16"
(2659 mm)
9' 10 7⁄8"
(3019 mm)
10' 7 11⁄16"
(3243 mm)
1' 11 13⁄16"
(605 mm)
23' 11 7⁄16" - 52' 5 15⁄16"
(7301 mm - 16000 mm)
9' 8 5⁄16"
(2955 mm)
10' 1 5⁄8"
(3089 mm)
11' 3 13⁄16"
(3449 mm)
12' 5⁄8"
(3673 mm)
3' 4 3⁄4"
(1035 mm)
32"
(800 mm)
8' 2 7⁄16" - 27' 10 5⁄8"
(2500 mm - 8500 mm)
8' 7 3⁄8"
(2625 mm)
9' 5⁄8"
(2759 mm)
10' 2 13⁄16"
(3119 mm)
10' 11 5⁄8"
(3343 mm)
2' 3 3⁄4"
(705 mm)
24"
(600 mm)
8' 2 7⁄16" - 34' 5 3⁄8"
(2500 mm - 10500 mm)
9' 8 5⁄16"
(2955 mm)
10' 1 5⁄8"
(3089 mm)
11' 3 13⁄16"
(3449 mm)
12' 5⁄8"
(3673 mm)
3' 4 3⁄4"
(1035 mm)
7
40"
(1000 mm)
3
15
1
DIMENSION AA/DD (LOWER HEAD) FOR NON-SEISMIC
AA
W1: Step Width
Truss/comb
heating
Level steps - up radius / low radius (m)
DD
2-1.0/1.0
2-1.5/1.0
3-1.5/1.0
3-2.7/2.0
40"
(1000 mm)
Without/With
7' 3 5⁄8" (2226 mm)
7' 3 5⁄8" (2226 mm)
8' 3 3⁄4" (2534 mm)
9' 1 5⁄16" (2777 mm)
1' 9 1⁄16" (535 mm)
32"/24"
(800 mm / 600 mm)
Without
7' 3 5⁄8" (2226 mm)
7' 3 5⁄8" (2226 mm)
8' 3 3⁄4 " (2534 mm)
9' 1 5⁄16" (2777 mm)
1' 9 1⁄16" (535 mm)
32"/24"
(800 mm / 600 mm)
With
8' 5 7⁄16" (2576 mm)
8' 5 7⁄16" (2576 mm)
9' 5 9⁄16" (2884 mm)
10' 3 1⁄8" (3127 mm)
2' 10 13⁄16" (885 mm)
HA
HB
CC
FF
HL
HU
3' 3" (990 mm)
3' 1" (940 mm)
1.73205 x H
AA+7' 1⁄2'
(AA+2139 mm)
3' 8 1⁄2" (1130 mm)
3' 8 1⁄2" (1130 mm)
KONE TransitMaster 220
Configuration & Dimensions
R
KEY WIDTH DIMENSIONS
W1: Step width
3'-3' 1⁄2" (1000 mm)
2' - 7' 1⁄2" (800 mm)
1'-11' 1⁄2" (600 mm)
W2: Handrail centerline distance
4'-1' 11⁄16" (1262 mm)
3'-5 7⁄8" (1064 mm)
2'-10' 1⁄8" (866 mm)
W4: Width of truss
4'-11' 7⁄16 (1510 mm)
4' - 3' 5⁄8 (1312 mm)
3' - 7' 7⁄8" (1114 mm)
W5: Width of finished escalator
5'- 3' 1⁄16" (1602 mm)
4' - 7' 1⁄4" (1404 mm)
3'-11' 1⁄2" (1206 mm)
W6: Width of pit
5'- 5' 1⁄16" (1650 mm)
4' - 9' 3⁄16" (1450 mm)
4' - 1' 5⁄16" (1250 mm)
EXTENSION BY SEISMIC TYPE
Seismic end
support type
Increase for
AA&BB&DD&EE
Type A
0' 1 3⁄4" (45 mm)
Type B
0' 1 3⁄4" (45 mm)
Type C
0' 3 1⁄8" (79 mm)
Type D
0' 4 1⁄16" (103 mm)
Type E
0' 5 5⁄8" (146 mm)
Type F
0' 8 1⁄16" (205 mm)
Type G
0' 10 5⁄16" (262 mm)
Type H
1' 5⁄16" (313 mm)
Notes
(1) Details represent standard KONE escalator
configurations. Please consult your sales
R
professional to review all possible deviations.
Visit KONE.us for the latest project-specific details,
electrical data, reaction loads, planner tools and
building access requirements.
*All drawings are for illustration purposes only.
KONE TRANSITMASTER 180
™
KONE TransitMaster 180 escalators are available in two step widths, glass or solid balustrades and many other available
options and finishes. The robust design, coupled with excellence in manufacturing and service help make KONE
TransitMaster 180 a great solution for public transportation applications such as railway or metro stations.
Detail 1
Detail 2
KONE TransitMaster 180 – Basic data
Inclination
30 degrees
Level Steps
2-4 Level Steps
Radii 4'-11" or 8'-10" (1.5 or 2.7 m)
Upper Radius
Maximum Vertical Rise
60'-0" (18 m)
Step Width
24", 32", 40"
(600, 800, 1000 mm)
Balustrade
Glass or Solid Inclined
Balustrade Height
3'-33⁄8" (1000 mm)
Speed
100 fpm (0.5 m/s)
Electrification
NFPA 70 and CSA-C22.1
Chain Type
Outside Chain Roller
Handrail
Environment
V-type
Indoor / Outdoor
Notes
(1) Details represent standard KONE escalator configurations. Please consult your Sales
Professional to review all possible deviations.
(2) For detailed options and dimensional design data, please contact a KONE Professional.
*All drawings are for illustration purposes only.
Visit kone.us for the latest project-specific details, electrical data, reaction loads,
architectural toolbox and building access requirements.
KONE TRANSITMASTER™
165/185 AUTOWALKS
Public Transportation Autowalk Product
Well designed and manufactured autowalks are a must for today’s highly demanding public areas.
They are key to ensuring the smooth, efficient and safe flow of people traveling in airport environments. We offer two different
types of solutions for your facility.
The main benefits of KONE TransitMaster 165/185
n
Safety and reliability
n
High quality in terms of technical performance and visual appearance
n
Optimized total cost of ownership
n
Flexible offering to cover the wide range of needs of the segment
n
Elegant, modern and harmonized design​
Main Characteristics of the TransitMaster 165/185
Inclination
Maximum length
Speed
Pallet width
Balustrade type
Balustrade height
​Handrail type
Pallet chains
TransitMaster 165
TransitMaster 185
Maximum 6°​
Maximum 6°​
196.85 ft (60m)​​
0.4m/s with inverter, 0.5m/s, 0.65m/s, 0.75m/​s
328.08 ft (100m)**
0.4m/s with inverter, 0.5m/s, 0.65m/s , 0.75m/s
​​3' 3 3/8" (1000 mm)
3' 3 3/8" (1000 mm)
3' 11 1/4" (1200 mm)
3' 11 1/4" (1200 mm)
​4' 7 1/8"​(1400 mm)
​4' 7 1/8"​(1400 mm)​
Glass, solid inclined​
Glass, solid inclined​
3' 3 3/8" (1000 mm)
3' 3 3/8" (1000 mm)
C-type
C- and V-type​
Inside roller chains
Outside roller chains​
Operational environment​
Indoor, semi-outdoor
Indoor, semi-outdoor
Duty cycle
20 – 24 hours/day***​
20 – 24 hours/day***​
** Longer units are available via order engineering. Please contact KONE for more information. *** 24 hours duty cycle is possible with additional maintenance.​
KONE ECOMOD
®
New escalators the quick
and easy way
It’s wise to modernize
KONE offers a complete escalator modernization solution
without the expense and disruption of removing the
existing truss. KONE EcoMod delivers brand new
escalator technology without the need to demolish floors,
roofs and building façades, and there’s always an escalator
available for passengers. KONE EcoMod is designed to be
compatible with both KONE escalators and equipment
from other manufacturers. During modernization we can
maintain continuous people flow through the ability to
keep one escalator running while we work on the other.
n
n
Lengthy process with extensive construction
New technology = better escalators
n
Substantial general contractor costs for work by others
KONE EcoMod installation advantages
n
n
Quicker, cleaner and less costly than a new installation
Modifying the existing truss means no major structural
modifications
Reuse of existing cladding and decking for significant
cost-savings
n
One or more escalators always available to passengers
n
Increased building value and simplified budgeting process
Traditional installation disadvantages
n
Additional time for removal and prep of structural and
related elements
n
Improved equipment dependability and performance
n
Enhanced safety and reliability
n
Energy-efficient technology to help lower operating costs
Complete escalator shutdown during construction
n
n
Major disruption to people flow
n
Improved user experience with smoother rides
n
Potential to increase building value
Note
(1) For additional information please contact your KONE Sales Professional.
Efficient installation
1
A KONE EcoMod complete escalator modernization begins
with the removal of all existing mechanical and electrical
components. The existing truss is then modified to accept
KONE EcoMod modules, allowing quick installation of the
latest technology without major disruption.
2
3
1 Upper module
2 Incline modules
3 Lower module
*All drawings are for illustration purposes only.
KONE provides innovative and
eco-efficient solutions for elevators,
escalators and the systems that integrate
them with today’s intelligent buildings.
We support our customers every step
of the way: from design, manufacturing
and installation to maintenance and
modernization. KONE is a global leader
in helping our customers manage the
smooth flow of people and goods
throughout their buildings.
Our commitment to customers is present
in all KONE solutions. This makes us a
reliable partner throughout the life cycle of
the building. We challenge the conventional
wisdom of the industry. We are fast, flexible,
and we have a well-deserved reputation as a
technology leader, with such innovations as
KONE MonoSpace® DX, KONE EcoMod®
and KONE UltraRope®.
KONE employs over 60,000 dedicated
experts to serve you globally and locally.
KONE
kone.us
Copyright © 2022 KONE Inc. All rights reserved. All examples and images are for illustration purposes only. Actual data, information, and results may vary.
*Separate agreement and charges apply. KONE maintenance agreement required. KONE not responsible for third-party wireless service interruptions.
SF2861 – Rev 0322
Printed in the U.S.
Download