ARCHITECTURAL PLANNING GUIDE REDEFINING ELEVATOR TECHNOLOGY Deliver a user experience that inspires, informs, and delights. With KONE MonoSpace DX elevators you can harness the power of digitalization to take the elevator journey far beyond the ordinary. Our goal is to create a user experience that both adds value to a building and maximizes comfort and safety for passengers. 1 Not only are our elevators now enabled with connectivity, we enhanced our elevator offering, so low, mid, and high rise buildings can take advantage of our technology. Our KONE MonoSpace 500 DX solution is enhanced to go higher and faster*. 2 KONE ECO-EFFICIENT SOLUTIONS 1 A green hoisting system The KONE EcoDisc permanent-magnet synchronous motor, together with a vector-controlled drive system and regenerative options, delivers eco-efficient operation for every KONE DX elevator. 2 Regenerative drive Regenerative drive technology recycles energy for immediate reuse within a building and can cut elevator energy consumption by up to 20%.** 3 Standby solutions Lights, signalization and ventilation can consume a considerable amount of electricity even when the elevator is not moving. KONE’s standby solutions cut energy consumption by powering down the equipment when it’s not in use. 3 4 Eco-efficient car lighting LED lighting is up to 80% more efficient and lasts up to 10 times longer than halogen lighting. 4 * Compared to KONE MonoSpace 500. Greater travel and speeds equal to or greater than 500 FPM available in select markets. ** Calculation based on the following: 3,500 lb. capacity, 350 fpm, 7 landings, 72 feet of travel and 200,000 starts per year. KONE ELEVATORS KONE MonoSpace® 300 DX ApplicationLow rise Type Machine room-less Powered by KONE EcoDisc Capacity 2000 - 3500 lbs. (907 - 1588kg) Speed 150 fpm (.75 m/s) Landings 2 to 4 The KONE MonoSpace 300 DX is a cost-effective elevator solution for low-rise buildings. It is durable, provides a wide range of cab interiors, stylish accessories, and easy to use signalization. KONE MonoSpace® 500 DX Application Low- to mid-rise; new buildings Type Machine room-less Powered by KONE EcoDisc Capacity 2000 – 5000 AIA lbs. (907 – 2268 kg) Speed 150, 200, 350, 500* fpm (.75, 1.0, 1.78, 2.54 m/s) Landings 5 to 36 The KONE MonoSpace 500 DX combines our proven eco-efficient technology with ride-comfort and design innovations. * Compared to KONE MonoSpace 500. Greater travel and speeds equal to or greater than 500 FPM available in select markets. KONE MonoSpace® 500 Flex DX Application Low- to mid-rise; existing buildings Type Machine room-less Powered by KONE EcoDisc Capacity 2000 – 5000 AIA lbs. (907 – 2268 kg) Speed 150, 200, 350 fpm (.75, 1.0, 1.78 m/s) Landings 2 to 15 Entrances Option to reuse existing entrances Flexible Platforms With accommodation of reduced overhead dimension KONE MonoSpace 500 Flex DX is a turnkey full-replacement elevator solution for existing hydraulic and traction elevator systems. KONE MonoSpace® 700 DX Application Mid- to high-rise Type Machine room-less Powered by KONE EcoDisc Capacity 2000 – 5000 AIA lbs. (907 – 2268 kg) Speed 200, 350, 500 fpm (1.00, 1.78, 2.54 m/s) Landings 6 to 36 KONE MonoSpace 700 DX is a fully customizable machine room-less solution for mid- to high-rise applications. KONE MiniSpace™ DX Application Mid- to high-rise Type Overhead machine room Powered by KONE EcoDisc Capacity 2000 – 5000 AIA lbs. (907 – 2268 kg) Speed200, 350, 400, 500, 700 fpm (1.00, 1.78, 2.00, 2.54, 3.56 m/s) Landings 6 to 63 For the latest product information and interactive design tools, visit kone.us KONE MiniSpace DX is an innovative, space efficient, mid-to high-rise solution. KONEMONOSPACE MONOSPACE300 300 KONE DX DX ® ® CONFIGURATIONS ATIONS && DIMENSIONS DIMENSIONS CONFIGUR Max Travel(8) 48 ft. (14.6 m) Speed(8) 150 fpm (.75 m/s) PASSENGER PASSENGER FRONT & REVERSE OPENING FRONT OPENING Max Landings 4 Car Height (F) 7 ft. 6 in. (2286 mm) Entrance Height (G) 7 ft. (2134 mm) (A) (A) SEISMIC (B) (B) SEISMIC (C) (D) (E) CAPACITY LBS. (kg) OPENING TYPE(10) HOISTWAY WIDTH (mm) HOISTWAY WIDTH (mm) HOISTWAY DEPTH (mm) HOISTWAY DEPTH (mm) INTERIOR WIDTH (mm) INTERIOR DEPTH (mm) DOOR WIDTH (mm) STRETCHER ACCOMMODATION(9) 2000 (907) Side Opening 7'-4" (2235) 7'-9" (2362) 5'-9" (1753) 5'-9 1/2" (1766) 5'-8 7/8" (1750) 4'-4 7/16" (1332) 3'-0" (914) NO 2500 (1134) Side Opening or Center Opening 8'-4" (2540) 8'-9" (2667) 5'-9" (1753) 5'-9 1/2" (1766) 6'-8 7/8" (2055) 4'-4 7/16" (1332) 3'-6" (1067) NO 3000 (1361) Side Opening or Center Opening 8'-4" (2540) 8'-7" (2616) 6'-3" (1905) 6'-3 1/2" (1918) 6'-5 5/8" (1971) 5'-0 7/16" (1536) 3'-6" (1067) NO 3500 (1588) Side Opening or Center Opening 8'-4" (2540) 8'-7" (2616) 6'-11" (2108) 6'-11" (2108) 6'-5 5/8" (1971) 5'-6 5/8" (1693) 3'-6" (1067) YES(9) 2000 (907) Side Opening 7'-4" (2235) 7'-9" (2362) 6'-3 3/4" (1924) 6'-3 3/4" (1924) 5'-8 7/8" (1750) 4'-4 7/16" (1332) 3'-0" (914) NO 2500 (1134) Side Opening or Center Opening 8'-4" (2540) 8'-9" (2667) 6'-3 3/4" (1924) 6'-3 3/4" (1924) 6'-8 7/8" (2055) 4'-4 7/16" (1332) 3'-6" (1067) NO 3000 (1361) Side Opening or Center Opening 8'-4" (2540) 8'-7" (2616) 6'-11 3/4" (2127) 6'-11 3/4" (2127) 6'-5 5/8" (1971) 5'-0 7/16" (1536) 3'-6" (1067) NO 3500 (1588) Side Opening or Center Opening 8'-4" (2540) 8'-7" (2616) 6'-5 5/8" (1971) 5'-6 5/8" (1693) 3'-6" (1067) NO CLEAR OVERHEAD (H) AND PIT DEPTH (I) 2000 to 3500 (907 to 1588) 7'-6" (2284) CONTROL SPACE 150 FPM (.75 m/s) CAPACITY LBS. (kg) 7'-6" (2286) (J) (K) (L) CAPACITY LBS. (kg) CONTROLLER SPACE WIDTH (mm) DEPTH (mm) DOOR WIDTH (mm) Pit Depth (mm) Clear Overhead (mm) 2000 to 3500 (907 to 1588) Remote Closet 4'-1" (1245) 1'-8" (508) 3'-6" (1067) 5'-0" (1524) 11'-8" (3556)(1) 2000 to 3500 (907 to 1588) Adjacent or Remote Room 5'-0" (1524) Dimension (B) 3'-0" (914) Visit kone.us for the latest project-specific details, CAD drawings, BIM models, CSI specifications, electrical data, reaction loads and building access requirements. Notes (1) An 8” inch tall hoist beam is required for installation (by others). Dimension (H) reflects 11’-8” clearance under hoist beam. This clearance is available with a flush or moveable hoist beam. (2) If an EBD (Emergency Battery Device) is required please contact your KONE Sales Professional for further detail regarding dimensions, (J) and (L). (3) The published hoistway (A) dimensions represent the minimum clear inside requirements. Construction efficiencies can be realized by increasing these dimensions by up to 2” (51 mm). (4) For pit depths less than 5’ (1524 mm) please contact a KONE Sales Professional. (5) The published interior width (C) and depth (D) dimensions represent the minimum clear inside requirements without raised panels. For interior width (C) and Depth (D) dimensions with raised panels please contact a KONE sales Professional. (6) A pit ladder wall pocket may be required. Please contact a KONE sales Professional. (7) Contact your local KONE Sales Professional regarding local code variations when utilizing the integrated remote closet options. (8) If IBC (International Building Code) 2018 or ASME A17.1-2019/CSA B44-19 code is applicable, contact your local sales professional for controller space configurations. (9) Stretcher accessibility based only for side opening type and International / California Building Code specified 24 inch by 84 inch stretcher with 5 inch degree radius corners. Customers in Canada, please review stretcher compliance with your local sales representatives. (10) All KONE MonoSpace 300 DX elevators utilize a single speed door. KONE MonoSpace 300 DX Plan Views Section View (3) (5) (A) (1) (C) (D) (B) (5) (H) (E) (F) (G) Integrated Control Solution (standard) (K) (L) Remote Control Closet (option 1) (2) (7) (J) TRAVEL (J) (4) (B) (G) (I) I Adjacent or Remote Control Room (option 2) (2) (7) (L) KONE kone.us Copyright © 2022 KONE Inc. This publication is for general informational purposes only. KONE Inc. reserves the right to alter the product design and specifications without prior notice. Minor differences between printed and actual colors may exist. KONE MonoSpace® DX is a registered trademark of KONE Corporation. SF3071- Rev 0322 Printed in the U.S. KONE MONOSPACE 500 DX KONE MONOSPACE 500 DX ® ® CONFIGUR ATIONS & DIMENSIONS CONFIGUR ATIONS & DIMENSIONS Travel (8) MaxMax Travel 150 ft. (45.7 m) (8) 150 ft. (45.7 m) Max Landings(8) 15 (8) Max Landings 15 Speed (8) Speed 150, 200, 350 fpm 150, 200, 350 fpm (.75, 1.0, 1.78 m/s) (.75, 1.0, 1.78 m/s) (8) PASSENGER PASSENGER SERVICE SERVICE PASSENGER PASSENGER SERVICE SERVICE Front & Reverse Opening FRONT & REVERSE OPENING Front Opening FRONT OPENING A CarHeight Height Car (F) F 8, 9 or 10 8, 9 or 10 ft.ft. (2438, 2743 or 3048 mm) (2438, 2743 or 3048 mm) (A) A SEISMIC (A) SEISMIC B (B) B SEISMIC (B) SEISMIC C (C) D (D) E (E) CAPACITY OPENING HOISTWAY INTERIOR INTERIOR DOOR WIDTH STRETCHER CAPACITY OPENING HOISTWAY HOISTWAY HOISTWAY HOISTWAY HOISTWAY HOISTWAY HOISTWAY INTERIOR INTERIOR DOOR STRETCHER (10) LBS.LBS. (kg)(kg) TYPE (mm)TYPEWIDTH (mm) WIDTH (mm) (mm)(mm) WIDTHWIDTH (mm) (mm) (mm) † WIDTH (mm) WIDTH (mm)DEPTH (mm) DEPTH (mm) DEPTH DEPTH (mm) DEPTH DEPTH (mm) WIDTH (mm) ACCOMMODATION ACCOMMODATION(10) 57 27 2000 (907) SSP 7'-6" (2286) 7'-11" (2413) 5'-9" (1753) 5'-9 1⁄ 2" (1766) 5'-8 ⁄ 64 " (1750) 4'-4 ⁄ 64 " (1332) 3'-0" (914) No 1 2000 (907) SSP 7'-6" (2286) 7'-11" (2413) 5'-9" (1753) 5'-8 7⁄8" (1750) 4'-4 7⁄ 16" (1332) 3'-0" (914) No 1 5'-9 ⁄ 2 " (1766) 27 2500 (1134) SSP-COSSP / CO 8'-6" (2591) 8'-11" (2718) (1766) 6'-8 29⁄6'-8 32" (2055) ⁄ 64" 7(1332) (1067) No 1 7 2500 (1134) 8'-6" (2591) 8'-11" (2718)5'-9" (1753) 5'-9" (1753)5'-9 1⁄ 2"5'-9 ⁄2" (1766) ⁄8" (2055)4'-4 274'-4 ⁄ 16" (1332) 3'-6"3'-6" (1067) No 47 (10) 2500 IBC (1134) (10) SSP 8'-11" (2718) 9'-5" (2870) 5'-9" (1753) 5'-9 ⁄ 2" (1766) 6'-11 ⁄ 64" (2127) 4'-4 ⁄ 64" 7(1332) 3'-6" (1067) Yes 1 3 SSP 8'-11" (2718) 9'-5" (2870) 5'-9" (1753) 5'-9 ⁄2" (1766) 196'-11 ⁄4" (2128) 4'-4 ⁄ 16" (1332) 3'-6" (1067) Yes 2500 IBC (1134) 3000 (1361) SSP-CO 8'-6" (2591) 8'-9" (2667) 6'-3" (1905) 6'-3 1⁄ 2" (1918) 6'-5 ⁄ 32" (1971) 5'-0 29⁄ 64" 7(1536) 3'-6" (1067) No 1 5 ⁄2" (1918) ⁄8" (1971) 5'-6 5'-0 ⁄ 16" (1536) 3'-6"3'-6" (1067) No 3000 (1361) 8'-6" (2591)8'-9" (2667) 8'-9" (2667)6'-11" (2108) 6'-3" (1905) 6'-11" 6'-3 5 3500 (1588) SSP-COSSP / CO 8'-6" (2591) (2108) 6'-5 19⁄6'-5 32" (1971) ⁄ 8" (1693) (1067) Yes 5 5 ⁄8" (1971) 5'-6 55'-6 ⁄8" (1693) 4'-0"3'-6" (1067) Yes 3500 (1588) 8'-6" (2591) 8'-9" (2667)6'-11" (2108) 6'-11" (2108)6'-11" (2108) 6'-11" (2108)7'-6 45⁄ 6'-5 4000 (1814) CO SSP / CO 9'-8" (2947) 9'-8" (2947) 64" (2304) ⁄ 8" (1693) (1219) Yes 11 5 4000 (1814) CO 9'-8" (2947) 9'-8" (2947) 6'-11" (2108) 6'-11" (2108) 7'-6 ⁄ 16" (2304) 5'-6 ⁄8" (1693) 4'-0" (1219) Yes 4000 (1814) 2SP 7'-8" (2337) 7'-8" (2337) 9'-2" (2794) 9'-2" (2794) 5'-7 3⁄ 32" (1704) 7'-7 29⁄ 32" 7(2335) 4'-0" (1219) Yes 4000 (1814) 2SP 7'-8" (2337) 7'-8" (2337) 9'-2" (2794) 9'-2" (2794) 5'-7 1⁄8" (1705) 7'-7 ⁄8" (2334) 4'-0" (1219) Yes 4500 (2041) 2SP 7'-8" (2337) 7'-8" (2337) 9'-8" (2946) 9'-8" (2946) 5'-7 3⁄ 32" (1704) 8'-1 13⁄ 16" 7(2485) 4'-0" (1219) Yes 1 4500 (2041) 2SP 7'-8" (2337) 7'-8" (2337) 9'-8" (2946) 9'-8" (2946) 5'-7 ⁄8" (1705) 8'-1 ⁄8" (2486) 4'-0" (1219) Yes 5000 (2268)(9) (9) 2SP 7'-10" (2388) 7’-10" (2388) 10'-2 1⁄ 2" (3112) 10'-2 1⁄ 2" (3112) 5'-7 3⁄ 32" (1704) 8'-9 21⁄ 32" 11(2684) 4'-6" (1372)(9) (9) Yes 1 1 1 (2388) 7'-10" (2388) ⁄2" (3112) 10'-2 ⁄2" (3112) ⁄8" (1705)9'-0 8'-9 ⁄ 16" (2685) 4'-6"4'-6" (1372) Yes (2268) 7 (9) 50005000 AIA (2268) 2SP 2SP 7'-10 5⁄ 16" 7'-10" (2396) 7'-11 1⁄ 2" (2426) 10'-5 1⁄ 1610'-2 " (3177) 10'-5 1⁄ 16 " (3177) 5’-9 13⁄5'-7 32" (1763) ⁄ 16" (2755) (1372) Yes 5 1 1 1 7 7 (9) 5000 AIA (2268) 2SP 7'-10 ⁄ 16" (2396) 7'-11 ⁄2" (2426) 10'-5 ⁄ 16" (3177) 10'-5 ⁄ 16" (3177) 5'-9 ⁄ 16" (1764) 9'-0 ⁄ 16" (2755) 4'-6" (1372) Yes 2000 (907) SSP 7'-6" (2286) 7'-11" (2413) 6'-3 3⁄ 4" (1924) 6'-3 3⁄ 4" (1924) 5'-8 57⁄ 64" (1750) 4'-4 27⁄ 64" 7(1332) 3'-0" (914) No 3 3 7 2000 (907) SSP 7'-6" (2286) 7'-11" (2413) 3 6'-3 ⁄4" (1924) 3 6'-3 ⁄4" (1924) 29 5'-8 ⁄8" (1750) 4'-4 ⁄ 16" (1332) 3'-0" (914) No 2500 (1134) SSP-CO 8'-6" (2591) 8'-11" (2718) 6'-3 ⁄ 4" (1924) 6'-3 ⁄ 4" (1924) 6'-8 ⁄ 32" (2055) 4'-4 27⁄ 64" 7(1332) 3'-6" (1067) No 3 3 7 2500 (1134) SSP / CO 8'-6" (2591) 8'-11" (2718) 3 6'-3 ⁄4" (1924) 3 6'-3 ⁄4" (1924) 6'-8 ⁄8" (2055) 4'-4 ⁄ 16" (1332) 3'-6" (1067) No 2500 IBC (1134)(5)(10)(5)(10) SSP 8'-11" (2718) 9'-5" (2870) 6'-3 ⁄ 4" (1924) 6'-3 ⁄ 4" (1924) 6'-11 47⁄ 64" (2127) 4'-4 27⁄ 64" 7(1332) 3'-6" (1067) Yes 3 3 3 SSP 8'-11" (2718) 9'-5" (2870) 3 6'-3 ⁄4" (1924) 3 6'-3 ⁄4" (1924) 196'-11 ⁄4" (2128) 4'-4 ⁄ 16" (1332) 3'-6" (1067) Yes 2500 IBC (1134) 3000 (1361) SSP-CO 8'-6" (2591) 8'-9" (2667) 6'-11 ⁄ 4" (2127) 6'-11 ⁄ 4" (2127) 6'-5 ⁄ 32" (1971) 5'-0 29⁄ 64" 7(1536) 3'-6" (1067) No 3 5 ⁄4" (2127) ⁄8" (1971) 5'-6 5'-0 ⁄ 16" (1536) 3'-6"3'-6" (1067) No (1361) 8'-6" (2591)8'-9" (2667) 8'-9" (2667)7'-6" (2286) 6'-11 3⁄4" (2127)7'-6" 6'-11 5 (10) 35003000 (1588) SSP-COSSP / CO 8'-6" (2591) (2286) 6'-5 19⁄6'-5 32" (1971) ⁄ 8" (1693) (1067) Yes* (10) 5 5 8'-6" (2591) 8'-9" (2667)7'-6" (2286) 7'-6" (2286) 7'-6" (2286) 7'-6" (2286)7'-6 45⁄ 6'-5 ⁄8" (1971) 5'-6 55'-6 ⁄8" (1693) 4'-0"3'-6" (1067) Yes* 3500 (1588) 4000 (1814) CO SSP / CO 9'-8" (2947) 9'-8" (2947) 64" (2304) ⁄ 8" (1693) (1219) Yes 4000 (1814) CO 9'-8" (2947) 9'-8" (2947) 7'-6" (2286) 7'-6" (2286) 7'-6 11⁄ 16" (2304) 5'-6 5⁄8" (1693) 4'-0" (1219) Yes 4000 (1814) 2SP 7'-8" (2337) 7'-8" (2337) 10'-2 1⁄ 8" (3102) 10'-2 1⁄ 8" (3102) 5'-7 3⁄ 32" (1704) 7'-7 29⁄ 32" 7(2335) 4'-0" (1219) Yes 1 1 1 4000 (1814) 7'-8" (2337) 7'-8" (2337) ⁄8" (3102) 10'-2 ⁄8" (3102) ⁄8" (1705)8'-1 137'-7 ⁄8" (2334) 4'-0"4'-0" (1219) Yes 4500 (2041) 2SP 2SP7'-8" (2337) 7'-8" (2337) 10'-8 1⁄ 1610'-2 " (3252) 10'-8 1⁄ 16 " (3252) 5'-7 3⁄ 325'-7 " (1704) ⁄ 16" 7(2485) (1219) Yes 1 1 1 4500 (2041) 2SP 7'-8" (2337) 7'-8" (2337) 7 10'-8 ⁄ 16" (3252) 710'-8 ⁄ 16" (3252) 3 5'-7 ⁄8" (1705) 4'-0" (1219) Yes 218'-1 ⁄ 8" (2486) (9) 5000 (2268)(9) (9) 2SP 7'-10" (2388) 7’-10" (2388) 11'-3 ⁄ 8" (3451) 11'-3 ⁄ 8" (3451) 5'-7 ⁄ 32" (1704) 8'-9 ⁄ 32" (2684) 4'-6" (1372) Yes 7 7 1 11 (9) 7'-10" (2388) ⁄8" (3451) 11'-3 ⁄8" (3451) ⁄8" (1705)9'-0 8'-9 ⁄ 16" (2685) 4'-6"4'-6" (1372) Yes (2268) 7 (9) 50005000 AIA (2268) 2SP 2SP 7'-10 5⁄ 16" 7'-10" (2396)(2388) 7'-11 1⁄ 2" (2426) 11'-6 11⁄ 1611'-3 " (3522) 11'-6 11⁄ 16 " (3522) 5'-9 13⁄5'-7 32" (1763) ⁄ 16" (2755) (1372) Yes 5000 AIA (2268) 2SP 7'-10 5⁄ 16" (2396) 7'-11 1⁄2" (2426) 11'-6 11⁄ 16" (3522) 11'-6 11⁄ 16" (3522) 5'-9 7⁄ 16" (1764) 9'-0 7⁄ 16" (2755) 4'-6" (1372)(9) Yes † SSP = Single Speed Side Opening / CO = Single Speed Center Opening / 2SP = Two Speed Side Opening CLEAR OVERHEAD PIT DEPTH H AND Visit kone.us for the latest project-specific details, CAD drawings, BIM models, CSI electrical data, Visitspecifications, kone.us for the latest projectreaction loads anddrawings, building BIM specific details, CAD accessCSI requirements. models, specifications, electrical data, reaction loads and building access requirements. I 150 FPM (0.75 M/S) CLEAR OVERHEAD (H) CAPACITY PIT DEPTH LBS. (kg) (mm) 2000 to 2500 CAPACITY 5'-0" (907 to 1134) LBS. (kg) (1524) 3000 to 3500 5'-0" 2000 to 2500(1524) (1361 to 1588) (907 to 1134) 4000 to 5000 AIA 5'-0" (1814 to 2268) 3000 to 3500(1524) (1361 to 1588) (11) CONTROL SPACE 4000 to 5000 AIA (1814 to 2268) CAPACITY LBS. (kg) 2000 to 5000 AIA (907 to 2268) CONTROL SPACE (11) 200 FPM (1.00 M/S) AND PIT DEPTH CLEAR (I) OVERHD (mm) 150 FPM (0.75 M/S) PIT DEPTH (mm) 5'-0" (1524) CONTROLLER SPACE 13'-8" (4166) remote closet 200 FPM (1.00 M/S) 2000 to 5000 AIA (907 to 2268) Remote Room 5'-0" (1524) PIT DEPTH (mm) 13'-4" (3988)CLEAR OVERHD (mm) 13'-4" (3988)13'-4" (4064) 13'-8" (4166)13'-4" (4064) J 5'-0" WIDTH (1524) (mm) 4'-0" (1219)(11) 350 FPM (1.78 M/S) CLEAR OVERHD (mm) 13'-0" 5'-0" PIT DEPTH(3962) CLEAR (1524) PIT DEPTH (mm) OVERHD (mm) (mm) 13'-0" 5'-0" 5'-0" (3962) 13'-0" (1524) 5'-0" (1524) (3962) (1524) 13'-8" 5'-0" 5'-0" (4166) 13'-0" (1524) 5'-0" (1524) (3962) (1524) 2000 to 5000 AIA adjacent or remote room (907CAPACITY to 2268) LBS. (kg) CONTROLLER SPACE Notes EntranceHeight Height Entrance (G)G 7, 8 or 9 ft. 7, 8 or 9 ft. (2134, 2438 or 2743 mm) (2134, 2438 or 2743 mm) 5'-6" PIT DEPTH (1676) (mm) 5'-6" 5'-6" (1676) (1676) 5'-6" (1676) 5'-6" (1676) K 13'-8" (4166) DEPTH (mm) (J) WIDTH (mm) 4'-1" (1245)(11) 1'-8" (508)(11) CLEAR OVERHD (mm) 350 FPM (1.78 M/S) 13'-6" CLEAR (4115) OVERHD (mm) 13'-6" 13'-6" (4115) (4115) 13'-8" (4166) 13'-6" (4115) L 13'-8" 5'-6" (1676) DOOR WIDTH (4166) (mm) (K) dimension (B) DEPTH (mm) 1'-8" (508)(11) 3'-6" (1067)(11) (L) 3'-0" (11) (914) DOOR WIDTH (mm) 3'-6" (1067)(11) (1) A hoist beam (by KONE) is required for installation 2000 (by others). (7) All dimensions are based on an 8'-0" (2438 mm) cab with a 7'-0" (2134 HAdjacent to 5000 Dimension AIA 5'-0" 3'-0" mm) Dimension (B) or Remote Room (907 to 2268) (1524) (914)(11) reflects clear under hoist beam. door. Alternate car and door heights are available, but will affect dimension H. Notes (2) If an Emergency Battery Device (EBD) is required, please contact your KONE Professional further detail regarding dimensions and L . H , J , Dimension (1) Sales A hoist beam (by for KONE) is required for installation (by others). (H) reflects clearAunder hoistdimension beam. represents the optimum clear inside (3) The published hoistway (8) 150 fpm (.75 m/s) only available up to 85 ft. (25 m) of travel and 10 dimensions landings. 200 (1.00 m/s) available to cab 100with ft. (30.5 m)(2134 of (7) All arefpm based on an 8'-0" (2438 up mm) a 7'-0" mm travel Alternate and 12 landings. door. car and door heights are available, but will affect dimension (H). (2) requirements If an Emergency Destination is required, andBattery maybe Device reduced(EBO) by uportoKONE 2” (51mm). However, this may pleaseincontact your KONE Sales Professional for further detail regarding result construction inefficiencies. dimensions (H), (J) and (L). (4) The published interior width C and depth D dimensions represent the (3) minimum The published hoistway dimension represents optimum clear inside clear (A) inside requirements without raised the panels. For interior requirements and maybe reduced by up to 2” (51mm). However, this may width C and depth D dimensions with raised panels please contact result in construction inefficiencies. a KONE Sales Professional. (4) The published interior width (C) and depth (D) dimensions represent the (5)2500 LB. IBC reverse must be diagonally opposed. For interior all other front minimum clear insideopening requirements without raised panels. For and reverse opening width is valid contact for directly A please width (C) and depth configurations, (D) dimensions hoistway with raised panels opposed openings only. If diagonally opposed openings are required, please a KONE Sales Professional. contact your KONE Sales Professional. (5) 2500 LB. IBC (International Building Code) reverse opening must be diagonally opposed. For all and reverseis opening configurations, (6 The published minimum pitother depthfront based upon slide I dimension hoistwayFor width (A) is valid for directly opposed openings only. If diagonally guides. minimum pit depth roller guides please contact I with openings are required, please contact your KONE Sales Professional. aopposed KONE Sales Professional. (9) 150 4'-0"fpm (1219 mm) also up available. (8) (.75 m/s)door onlywidth available to 85 ft. (25 m) of travel and 10 landings. fpm (1.00 m/s) available upinternational to 100 ft. (30.5 m) ofcode travel(IBC) and and 12 landings. (10) 200 Stretcher accessibility based on building (6) The published minimum pit depth (I) dimension is based upon slide guides. For minimum pit depth (I) with roller guides please contact a KONE Sales Professional. California Building Codewidth specified, 24 inch by 84 inch stretcher — with (9) 4’-0” (1219 mm) door also available. 5-degree radius corners. Elevator car must utilize a sidecode slide (IBC) door with (10) Stretcher accessibility based on international building and the exception Building of the 4000 LB.specified, passenger24shaped car. Canada (NBCC) 2500 LB. California Code inch by 84Ininch stretcher - with and larger elevators with single car slidemust doors meeta Canadian 5-inch radius corners. Elevator utilize side slide stretcher door withrule theof exception the 4000 LB. passenger shaped car. In Canada (NBCC) 2500 2010mm xof610mm. LB. and larger elevators with single slide doors meet Canadian stretcher (11) If IBC 2018 or ASME A17.1-2019/CSA B44-19 code is applicable, contact rule of 2010mm x 610mm. your local sales professional for controller space configurations. (11) If IBC (International Building Code) 2018 or ASME A17.1-2019/CSA B44-19 code is LB. applicable, contactelevators your localneeds sales to professional for controller *3,500 Front / reverse have diagonal opposed space doors configurations. and a wider hoistway width of 8’-9” (8’-11” if seismic) to accommodate a stretcher. KONE Sales Professional for more information. * 3,500 LB. Please Front /contact reverse aelevators needs to have diagonal opposed doors and a wider hoistway width of 8' -9" (8' -11" if seismic) to accommodate a stretcher. Please contact a KONE Sales Professional for more information. (4) E (A) Section Sectionview View A C (1) (1) (C) (E) D B (4) (2) (7) H (2) (7) F (H) G (F) (G) (D) (B) (4) (2) E Integral Control Solution (standard) (E) Integrated Control Solution (standard) (K) K L J (2) TRAVEL (K) G TRAVEL (G) (6) (11) I (6) (12) (I) I Remote Control Closet (option 1) (L) (J) (2) (2) J Remote Control Closet (option 1) (2) (12) (13) (J) B Notes, continued: Please consult a KONE Sales Professional regarding: Notes, continued: (12) Pit depths less than 5'-0" (1524 mm). (B) Adjacent or Remote Control Room (option 2) L Adjacent or Remote Control Room (option 2) (L) Please consult(13) a KONE Sales space Professional regarding: Occupied beneath the hoistway. (11) Pit depths lessLocal thancode 5'-0" variations (1524 mm). (14) when utilizing the integrated, integral andthe remote closet options. (12) Occupied space beneath hoistway. (13) Local code variations when utilizing the integrated, integral and remote closet options. For configuration guidance or more information scan this code or visit our website to get in touch with a KONE Sales Professional: kone.us/ms500dx KONE kone.us Copyright © 2022 KONE Inc. This publication is for general informational purposes only. KONE Inc. reserves the right to alter the product design and specifications without prior notice. Minor differences between printed and actual colors may exist. KONE MonoSpace® DX is a registered trademark of KONE Corporation. SF2982 - Rev 0822 Printed in the U.S. KONE MonoSpace 500 DX PlanViews views Plan (4) KONE MONOSPACE 500 FLEX DX ® KONE MonoSpace 500 Flex DX is a full replacement elevator solution for existing buildings. KONE MonoSpace 500 Flex DX advantages n Replacing your elevators Instead of replacing your aging elevators with similar technology, KONE offers you an advanced, state-of-the-art solution. Our innovative machine room-less design is the first turnkey full replacement elevator solution for existing hydraulic and traction elevator systems. Thanks to the revolutionary KONE EcoDisc® motor, KONE MonoSpace 500 Flex DX is designed to fit into existing hoistways. From the initial planning stages and site surveys through final completion, KONE works to ensure the entire process is well-planned and streamlined in order to minimize disruption to your building. F or the owner: Minimized building disruption, increased property value, accommodation of reduced overhead dimension. Building owners who purchase the Integrated Control Solution (ICS) will gain back additional space in their facility, no longer requiring a machine room. Therefor mandatory code related updates for machine room are not needed either. The new space can be used to fit the building owners needs. n n F or the tenant: Smoother, quieter ride, no hydraulic oil odor, optimum stopping accuracy, sophisticated car features F or the environment: No hydraulic oil, energy-efficient, ability to recycle existing elevator where feasible, option to retain and reuse existing entrances KONE MonoSpace 500 Flex DX 1 2 6 8 1 Space efficiency With the machine in the hoistway and the controller accessible from the top landing, the space previously needed for a dedicated machine room or control space can be allocated for more profitable uses. 2 Energy efficiency In addition to the efficient KONE EcoDisc® hoisting machine, advanced standby solutions save energy by powering down the equipment when it’s not in use. 3 Minimized disruption The compact design fits inside existing hoistways, minimizing the need for modifications. 4 Reusable entrances The ability to interface with most existing entrances reduces the need for significant structural modifications. 3 5 4 5 Modern, code-compliant Modern, simple and code-compliant operating displays. 6 High performance Passengers enjoy smooth acceleration and deceleration, accurate leveling and a quiet, comfortable ride. 7 No oil When applicable, the existing hydraulic cylinder is drained of all oil and capped, ensuring oil-free, environmentally friendly operation. 8 Integrated Control Solution (ICS) An integrated control solution is available for units up to 350 FPM and 3500 lb. capacity. Use of ICS allows KONE to return existing machine room space back to the building for ownership’s use. 9 Destination control The KONE Destination can significantly improve convenience in your building while enhancing the appearance of your lobby. Please consult your KONE Sales Professional. 7 KONE MONOSPACE 700 DX ® ® MACHINE AT REAR CONFIGUR ATION & DIMENSIONS MACHINE AT REAR CONFIGUR ATION & DIMENSIONS Available in passenger shape with front opening option Max Travel 300 ft. (91.4 m) Speed 200, 350, 500 fpm FRONT OPENING (1.0,CAPACITY 1.78, 2.54OPENING m/s) Travel MaxMax Landings 36 300 ft. (91.4 m) PASSENGER Max Landings 36 lbs. (kg) TYPE 2000 (907) 2500 (1134) 3000 (1361) 3500 (1588) 4000(A) (1814) SSP SSP-CO SSP-CO SSP-CO CO A HOISTWAY WIDTH (mm) 7'-4" (2235) 8'-4" (2540) 8'-4" (2540) 8'-4" (2540) (2845) (A) 9'-4" SEISMIC Available Speed in passenger shape with front opening option PASSENGER 200, 350, 500 fpm FRONT (1.00,OPENING 1.78, 2.54 m/s) CAPACITY F Car Height LBS. (kg) 8, 9 or 10 ft. 2000 (907) (2438, 2743 or 3048 mm) 2500 (1134) OPENING TYPE† HOISTWAY 7'-4" (2235) HOISTWAY CLEAR Entrance Height G SSP / CO CAPACITY DEPTH PIT DEPTH8'-8" 3000 (1361) 8'-4"PIT (2540) (2642) OVERHD lbs. (kg) (mm) (mm) (mm) 7, 8 or 9 ft. 3500 (1588) SSP / CO 8'-4" (2540) 8'-8" (2642) 2000 5'-3" 5'-3" 15'-6" (2134, 2438 (907) (1600) (1600) (4724) 4000mm) (1814) CO 9'-4" (2845) 9'-8" (2946) or 2743 2500 5'-3" 5'-3" 15'-0" (1134) (1600) (1600) (4572) † SSP = Single Speed Side Opening / CO = Single Speed Center Opening 3000 5'-3" 5'-3" 15'-2" (1361) (1600) (1600) (4623) 3500 5'-5" 5'-5" 14'-10" CLEAR OVERHEAD (H) AND PIT DEPTH (1588) (I) (1651) (1651) (4521) Visit kone.us for the latest 4000 5'-6" 5'-6" 15'-1" 200 FPM (1.00 M/S) project-specific details, BIM (1814) (1676) (1676) (4597) (H) (H) SEISMIC CONTROL SPACE (I) WIDTH (mm) DEPTH (mm) WIDTH (mm) 6'-8" (2032) 6'-8" (2032) 7'-2" (2184) 7'-10" (2388) 7'-10" (2388)(C) 5'-8½" (1740) 6'-8½" (2045) 6'-8½" (2045) 6'-8½" (2045) 7'-8½" (2350) 4'-3¼" (1302) 4'-3¼" (1302) 4'-9¼" (1454) 5'-5¼" (1657) 5'-5¼" (D) (1657) 3'-0" (914) 3'-6" (1067) 3'-6" (1067) 3'-6" (1067) 4'-0" (1219) (E) HOISTWAY DEPTH (mm) 200 FPM7'-8" (1.00 M/S) (2337) Entrance Height (G) 7, 8 or 9 D ft. C E (2134, 2438 or 2743 mm) INTERIOR INTERIOR DOOR DEPTH (mm) 7'-8" (2337) 8'-8" (2642) 8'-8" (2642) 8'-8" (2642) 9'-8" (2946) (B) I I SEISMIC H H SEISMIC 8'-4" (2540) 8'-8" (2642) SSP / CO DEPTH PIT DEPTH reaction loadsPITand building (mm) (mm) access requirements. WIDTH (mm) (mm) CLEARWIDTH OVERHEAD PIT(mm) DEPTH I H ANDWIDTH SSP Models, CAD drawings, CAPACITY (I) (I) SEISMIC specifications, electrical data, LBS. (kg) Car Height (F) 8,A 9SEISMIC or 10 ft. B (2438, 2743 or HOISTWAY 3048 mm) HOISTWAY INTERIOR WIDTH (mm) INTERIOR DEPTH (mm) DOOR WIDTH (mm) 350 FPM (1.78 M/S) 6'-8" (2032) 5'-8½" (1740) 500 FPM (2.54 M/S) 4'-3¼" (1302) 3'-0" (914) I SEISMIC 6'-8"I (2032) SEISMIC I4'-3¼"I (1302) H (2045) H SEISMIC 6'-8½" H H SEISMIC 3'-6" (1067) CLEAR CLEAR CLEAR CLEAR CLEAR DEPTH PIT DEPTH OVERHD DEPTH DEPTH OVERHD 7'-2" (2184) 6'-8½" (2045) 4'-9¼"PIT (1454) 3'-6"OVERHD (1067) OVERHD PIT OVERHD PIT(mm) (mm) (mm) (mm) (mm) (mm) (mm) (mm) (mm) 7'-10" (2388) 6'-8½" (2045) 5'-5¼" (1657) 3'-6" (1067) 16'-11" 5'-7" 6'-7" 16'-11" 16'-11" 5'-7" 6'-7" 16'-11" 16'-11" (5156) (1702) (2007) (5156) (5156) (1702) (2007) (5156) (5156) 7'-10" (2388) 7'-8½" (2350) 5'-5¼" (1657) 4'-0" (1219) 16'-11" 5'-5" 6'-5" 16'-7" 16'-11" 5'-5" 6'-5" 16'-7" 16'-11" (5156) (1651) (1956) (5055) (5156) (1651) (1956) (5055) (5156) 16'-11" 5'-5" 6'-5" 16'-10" 16'-11" 5'-5" 6'-5" 16'-10" 16'-11" (5156) (1651) (1956) (5131) (5156) (1651) (1956) (5131) (5156) 16'-11" 5'-5" 6'-5" 16'- 4" 16'-11" 5'-5" 6'-5" 16'- 4" 16'-11" (5156) (1651) (1956) (4978) (5156) (1651) (1956) (4978) (5156) 16'-11" 5'-6" 6'-6" 16'-7" 16'-11" 7'-5" 8'-5" 16'-11" 16'-11" 350 FPM (1.78 M/S) 500 FPM (2.54 M/S) (5156) (1676) (1981) (5055) (5156) (2261) (2565) (5156) (5156) (I) SEISMIC (H) J (H) SEISMIC (I) K (I) SEISMIC (H) L (H) SEISMIC 3000 (1361) CLEAR OVERHD CLEAR OVERHD (mm) CAPACITY(mm) lbs. (kg) 5'-3" (1600) 5'-3" (1600) 15'-6" (4724) 16'-11" 2000 to 4000 (5156) (907 to 1814) 5'-3" (1600) 5'-3" (1600) 15'-0" (4572) 16'-11" (5156) 2000 to 4000 (907 to 1814) 5'-3" (1600) 5'-3" (1600) 15'-2" (4623) 16'-11" (5156) 3500 (1588) 5'-5" (1651) 5'-5" (1651) 14'-10" (4521) 16'-11" (5156) 5'-5" (1651) 6'-5" (1956) 16'- 4" (4978) 16'-11" (5156) 5'-5" (1651) 6'-5" (1956) 16'- 4" (4978) 16'-11" (5156) 4000 (1814) Notes 5'-6" (1676) 5'-6" (1676) 15'-1" (4597) 16'-11" (5156) 5'-6" (1676) 6'-6" (1981) 16'-7" (5055) 16'-11" (5156) 7'-5" (2261) 8'-5" (2565) 16'-11" (5156) 16'-11" (5156) 2000 (907) 2500 (1134) PIT DEPTH PIT DEPTH CLEAR OVERHD CLEAR OVERHD PIT DEPTH PIT DEPTH CLEAR OVERHD CLEAR OVERHD CONTROLLER DOOR WIDTH (mm) (mm) (mm) (mm) WIDTH (mm) (mm)DEPTH (mm) (mm) SPACE (mm) (mm) (mm) 5'-7" (1702) 6'-7" (2007) 16'-11" (5156) 16'-11" (5156) 5'-7" (1702) 6'-7" (2007) 16'-11" (5156) 16'-11" (5156) integral or remote cabinet 4'-4" (1321) 1'-8" (508) 4'-0" (1219) 5'-5" (1651) 6'-5" (1956) 16'-7" (5055) 16'-11" (5156) 5'-5" (1651) 6'-5" (1956) 16'-7" (5055) 16'-11" (5156) adjacent or remote room 5'-0" (1524) dimension (B) 3'-0" (914) 5'-5" (1651) 6'-5" (1956) 16'-10" (5131) 16'-11" (5156) 5'-5" (1651) 6'-5" (1956) 16'-10" (5131) 16'-11" (5156) (1) S maller pit and overhead dimensions may be available per specific applications. Contact your KONE Sales Professional for further information. (2) Buffer serviceCONTROL platformsSPACE are required when pit depth exceeds 8'-6" (2590 mm). (10) (J) (K) (L) (3) Hoist beams (by KONE) are required for installation (by others). Dimension H reflects clear under hoist beam. Visit kone.us for the latest project-specific CONTROLLER SPACE WIDTH (mm) DEPTH (mm) DOOR WIDTH (mm) CAPACITY LBS. (kg) details, BIM Models, CAD drawings, (4) If occupied space exists below the hoistway, consult your KONE Sales Professional. 2000 to 4000 specifications, electrical data, reaction Integral or Remote Cabinet 4'-4" (1321) 1'-8"car (508) 4'-0" (1219) (5) All dimensions are(907 based on an 8'-0" (2438 mm) cab with a 7'-0" (2134 mm) door. Alternate and door heights are to 1814) loads and building access requirements.available, but may affect dimension H . 2000 to 4000 Dimension (B) Adjacent or Remote Room 5'-0" (1524) 3'-0" (914) (6) Add 8" (203 mm)(907 in non-seismic and 12" (305 mm) in seismic zones to clear overhead dimension H for front-only to 1814) passenger car if cab features glass-back wall. Notes (7) If an Emergency Battery Device (EBD) is required, please contact your KONE Sales Professional for further details regarding dimensions J and L . (1) Smaller pit and overhead dimensions (8) mayContact be available (6)regarding Add 8" (203 non-seismic and 12" (305 in seismic zones to your per localspecific KONE applications. Sales Professional localmm) codeinvariations when utilizing themm) integral and remote Contact your KONE Sales Professional forcloset further information. clear overhead dimension (H) for front-only passenger car if cab features options. glass-back wall. (2) Buffer service platforms are required when depthKONE exceeds 8'-6" (2590 (9) If pit utilizing Destination or mm). KONE Access™, contact your local KONE Sales Professional regarding control space (7) If an Emergency Battery Device (EBD) is required, please contact your size requirements. (3) Hoist beams (by KONE) are required for installation (by others). Dimension (H) KONE Sales Professional for further details regarding dimensions (J) and (L). reflects clear under hoist beam. (4) If occupied space exists below the hoistway, consult your KONE Sales Professional. (8) Contact your local KONE Sales Professional regarding local code variations when utilizing the integral and remote closet options. (5) All dimensions are based on an 8'-0" (2438 mm) cab with a 7'-0" (2134 mm) door. Alternate car and door heights are available, but may affect dimension (H). (9) If utilizing KONE destination control system or KONE Access™, contact your local KONE Sales Professional regarding control space size requirements. Plan views A C Plan Views Section View (A) (C) KONE MonoSpace 700 DX Section view (3) (3) (5) (6) H D B K (D) (B) E (5) (6) (H) F (F) G (G) L J (7) TRAVEL Integral Control Closet (standard) G (K) (E) (7) (L) (J) (1) (2) I J (7) (4) Integrated Control Closet K (standard) TRAVEL L (G) B J (7) (7) Remote Control Closet (option 1) (J) (1) (2) L (K) Adjacent or Remote Control Room (option 2) (L) (I) I (4) (B) (J) (7) Remote Control Closet (option 1) (L) Adjacent or Remote Control Room (option 2) Talk to a sales expert! Get the right specifications and connect with a KONE Sales Professional. Scan this QR code or visit the link. kone.us/700dxrear KONE kone.us Copyright © 2022 KONE Inc. This publication is for general informational purposes only. KONE Inc. reserves the right to alter the product design and specifications without prior notice. Minor differences between printed and actual colors may exist. KONE MonoSpace® DX and KONE Access™ are registered trademarks or trademarks of KONE Corporation. SF2984 - Rev 0422 Printed in the U.S. KONE MONOSPACE DX DX KONE MONOSPACE700 700 ® ® MACHINE MACHINE AT AT SIDE SIDE CONFIGUR CONFIGUR ATION ATION & & DIMENSIONS DIMENSIONS Available in passenger and service shape with front and rear opening options Max Travel 300 ft. (91.4 m) Speed 200, 350, 500 fpm (1.0, 1.78, 2.54 m/s) Max Landings 36 CAPACITY lbs. (kg) A Car Height (F) 8, 9 or 10 ft. A SEISMIC B 3048 mm) B SEISMIC (2438, 2743 or OPENING HOISTWAY HOISTWAY HOISTWAY TYPE WIDTH (mm) WIDTH (mm) DEPTH (mm) Entrance Height G 5000 (2268) 7, 8 or 9 ft. 5000 AIA (2268) (2134, 2438 or 2500 (1134) 2743 mm) SSP / CO CO 2SP 2SP 2SP 2SP SSP / CO 3000 (1361) SSP / CO 3500 (1588) SSP / CO 4000 (1814) CO SERVICE 9'-5" (2870) 9'-9" (2972) (2261) 2500 (1134) SSP-CO 9'-5" (2870) 7'-5" 9'-9" (2972) 3000 (1361) SSP-CO 9'-5" (2870) 7'-5" 9'-9" (2972) 10'-5" (3175) 10'-9" (3277) (2261) 3500 (1588) SSP-CO 9'-5" (2870) 9'-9" (2972) 8'-5" (2565) 8'-9" (2667) 9'-5" (2870) 4000 (1814) CO 10'-5" (3175) 10'-9" (3277) 8'-5" (2565) 8'-9" (2667) 9'-11" (3023) 4000 (1814) 2SP 8'-5" (2565) 8'-9" (2667) 8'-5" (2565) 8'-9" (2667) 10'-2" (3099) 4500 (2041) 2SP 8'-5" (2565) 8'-9" (2667) 8'-5" (2565) 8'-9" (2667) 10'-7¾" 5000 (2268) 2SP 8'-5" (2565) 8'-9"(3245) (2667) 5000 AIA (2268) 2SP 8'-5" (2565) 8'-9" (2667) 9'-5" (2870) 9'-9" (2972) 7'-1" (2159) PASSENGER SSP / CO HOISTWAY INTERIOR INTERIOR DOOR DEPTH (mm) WIDTH (mm) DEPTH (mm) WIDTH (mm) 7'-1" (2159) 6'-8½" (2045) 4'-3¼" (1302) 3'-6" (1067) SSP-CO 9'-5" (2870) 9'-9" (2972) 7'-1" (2159) 7'-4" (2235) 6'-8½" (2045) 4'-9¼" (1454) 3'-6" (1067) SSP-CO 9'-5" (2870) 9'-9" (2972) 7'-5" (2261) (A) SEISMIC (B) (B) SEISMIC 7'-8" (2337)(C) 6'-8½" (2045) 5'-5¼" (D) (1657) 3'-6" (1067) (E) CO 10'-5" (3175) 10'-9" (3277) 7'-5" (2261) 7'-8" (2337) 7'-8½" (2350) 5'-5¼" (1657) 4'-0" (1219) HOISTWAY HOISTWAY HOISTWAY INTERIOR INTERIOR DOOR 2SP 8'-5" (2565) DEPTH 8'-9"(mm) (2667) 9'-5" (2870) 5'-8½" (1740)DEPTH 7'-6" (2286) 4'-0" (1219) WIDTH (mm) DEPTH (mm) 9'-8" (2946) WIDTH (mm) (mm) WIDTH (mm) 2SP 8'-5" (2565) 8'-9" (2667) 9'-11" (3023) 10'-2" (3099) 5'-8½" (1740) 8'-0" (2438) 4'-0" (1219) 9'-9" (2972) (2083) 7'-1" (2159) 10'-5" 6'-8½" 4'-3¼" (1302) 3'-6" (1067) (9) 2SP 8'-5" (2565)6'-10" 8'-9" (2667) 10'-2" (3099) (3175) (2045) 5'-8½" (1740) 8'-7¾" (2635) 4'-6" (1372) (9) 2SP 8'-5" (2565) 7'-1" 8'-9" (2667) 10'-7¾" (3321)(2045) 5'-8½" (1740) 9'-0" (2743) 4'-6" (1372) 9'-9" (2972) (2159) 7'-4"(3245) (2235) 10'-10¾" 6'-8½" 4'-9¼" (1454) 3'-6" (1067) SERVICE 4500 (2041) SSP / CO Front & Reverse Opening PASSENGER SERVICE F Car Height 3500 (1588) 8, 9 or 10 ft. 4000 (1814) (2438, 2743 or 4000 (1814) 3048 mm) PASSENGER FRONT & REVERSE OPENING 3000 (1361) OPENING TYPE† 3000 (1361) 3500 (1588) (A) 4000 (1814) HOISTWAY 4000 (1814) WIDTH (mm) 4500 (2041) 9'-5" (2870) 5000 (2268) 5000(2870) AIA (2268) 9'-5" 7'-8" (2337) 7'-1" (2159) 7'-6" (2286) 7'-8" (2337) 7'-9½" (2375) 9'-8" (2946) 7'-9½" (2375) 10'-2" (3099) 10'-1" (3073) 10'-5" (3175) 10'-7" (3226) 6'-8½" (2045) 5'-5¼" (1657) 3'-6"(1067) (1067) 7'-1" (2159) 6'-8½" (2045) 4'-3¾" (1314) 3'-6" 7'-6" (2286) 6'-8½" (2045) 4'-9¾" (1467) 3'-6" 7'-8½" (2350) 5'-5¼" (1657) 4'-0"(1067) (1219) 7'-9½" (2375) 6'-8½" (2045) 5'-5¾" (1670) 3'-6" (1067) 5'-8½" (1740) 7'-6" (2286) 4'-0" (1219) 7'-9½" (2375) 7'-8½" (2350) 5'-5¾" (1670) 4'-0" (1219) 5'-8½" (1740) 8'-0" (2438) 4'-0" (1219) 10'-1" (3073) 5'-8½" (1740) 7'-6½" (2299) 4'-0" (1219) (9) 5'-8½" (1740) 8'-7¾" (2635) 4'-6" (1372) 10'-7" (3226) 5'-8½" (1740) 8'-0½" (2451) 4'-0" (1219) (9)(9) 10'-10¾" (3321) (2743) 4'-6"(1372) (1372) 11'-2¾" (3422) 11'-2¾"5'-8½" (3422)(1740) 5'-8½" (1740)9'-0" 8'-8¼" (2648) 4'-6" 11'-6¾" (3524) 11'-6¾" (3524) 5'-8½" (1740) 9'-0" (2743) 4'-6" (1372)(9) 7'-1" (2159) 6'-8½" (2045) 4'-3¾" (1314) 3'-6" (1067) 9'-5" (2870) 9'-9" (2972) 7'-6" (2286) 7'-6" (2286) 6'-8½" (2045) 4'-9¾" (1467) 3'-6" (1067) 9'-5" (2870) 9'-9" (2972) 7'-9½" (2375) 7'-9½" (2375) 6'-8½" (2045) 5'-5¾" (1670) 3'-6" (1067) 10'-5" (3175) CAPACITY lbs.(2565) (kg) 8'-5" 10'-9" (3277) PIT DEPTH (mm) 8'-9" (2667) CLEAR OVERHD (mm) 10'-1" (3073) 7'-9½" (2375) PIT DEPTH (mm)(3073) 10'-1" CLEAR OVERHD 5'-8½"(mm) (1740) 5'-5¾" (1670) PIT DEPTH (mm) (2299) 7'-6½" CLEAR OVERHD 4'-0"(mm) (1219) 5'-11" (1803) 10'-7"(4140) (3226) 13'-7" 13'-7" (4140) 11'-2¾" (3422) 13'-7" (4140) 11'-6¾" (3524) 13'-7" (4140) 14'-9" (4496) 15'-2" (4623) 10'-7" (3226) 5'-5" (1651) 5'-5" (1651) 11'-2¾" (3422) 5'-5" (1651) 11'-6¾" (3524) 5'-8" (1727) 5'-11" (1803) 5'-11" (1803) 5'-8½" (1740) 13'-11" (4242) 14'-4" (4369) 5'-8½" (1740) 14'-9" (4496) 5'-8½" (1740) 14'-11" (4547) 15'-3" (4648) 15'-11" (4551) 8'-0½" (2451) 5'-5" (1651) 5'-5" (1651) 8'-8¼" (2648) 5'-5" (1651) 9'-0" (2743) 7'-3" (2210) 7'-6" (2286) — 4'-0" (1219) 13'-11" (4242) 14'-4" (4369) 4'-6" (1372)(9) 14'-9" (4496) 4'-6" (1372)(9) 15'-8" (4775) 16'-0" (4877) — CLEAR OVERHEAD H AND PIT DEPTH I 200 FPM (1.007'-9½" M/S)(2375) Visit kone.us the latest 2SP 4000 for (1814) project-specific details, BIM 2SP 4500 (2041) 8'-5" 8'-9" (1600) (2667) 2500(2565) (1134) 5'-3" Models, CAD drawings, 3000(2565) (1361) 5'-5" 5000 (2268) 2SP 8'-5" 8'-9" (1651) (2667) specifications, electrical data, 3500 (1588) 5'-5" (1651) 5000 AIA (2268) 2SP 8'-5" (2565) 8'-9" (2667) reaction loads and building 4000 (1814) 5'-8" (1727) 4500Opening (2141)/ 2SP = Two 5'-8" (1727) requirements. †access SSP = Single Speed Side Opening / CO = Single Speed Center Speed Side Opening SERVICE FRONT OPENING Speed CAPACITY LBS. (kg) 200, 350, 500 fpm 2500 (1134) (1.00, 1.78, 2.54 m/s) Front Opening Max Landings 36 PASSENGER Max Travel Available in passenger and service2500 shape front9'-5" and rear9'-9" opening options. 300 ft. (91.4 m) (1134) with SSP-CO (2870) (2972) 6'-10" (2083) Entrance Height (G) 7, 8 or 9 ft. C (2134, 2438Dor 2743 mm)E 5000 – 5000 AIA (2268) 350 FPM (1.78 7'-8½" M/S) (2350) 500 FPM (2.54 M/S) 4'-0" (1219) CLEAR OVERHEAD (H) AND PIT DEPTH (I) CAPACITY LBS. (kg) (10) CONTROL SPACE 200 FPM (1.00 M/S) J M/S) 350 FPM (1.78 2500 (1134) CAPACITY CONTROLLER PIT DEPTH (mm) lbs. (kg) CLEAR OVERHD (mm) SPACE PIT DEPTH (mm) 2500 to 5000 AIA integral or (1134 to 2268)13'-7" (4140) remote cabinet 5'-3" (1600) 5'-5" (1651) 3000 (1361) 2500 to 5000 AIA adjacent or 5'-5" (1651) (1134 to 2268)13'-7" (4140) remote room5'-5" (1651) K WIDTH (mm) CLEAR OVERHD (mm) 4'-4" (1321)(10) 13'-11" (4242) 5'-0" (1524)14'-4" (4369) L 500 FPM (2.54 M/S) DEPTH (mm) PIT DEPTH (mm) 1'-8" (508)(10) 5'-5" (1651) dimension (B) 5'-5" (1651) DOOR WIDTH (mm)OVERHD (mm) CLEAR 4'-0" (10) (1219) 13'-11" (4242) 3'-0" (10) (4369) 14'-4" (914) 3500 (1588) 5'-5" (1651) 13'-7" (4140) 5'-5" (1651) 14'-9" (4496) 5'-5" (1651) 14'-9" (4496) 4000 (1814) 5'-8" (1727) 13'-7" (4140) 5'-8" (1727) 14'-11" (4547) 7'-3" (2210) 15'-8" (4775) 4500 (2041) further information. 5'-8" (1727) 14'-9" (4496) 5'-11" (1803) 15'-3" (4648) 7'-6" (2286) 16'-0" (4877) — — 5000 – 5000 AIA (2268) Notes (1) Smaller pit and overhead dimensions may be available per specific applications. Contact your KONE Sales Professional for (2) B uffer service platforms are required when pit depth exceeds 15'-11" 8'-6" (2590 mm). 5'-11" (1803) 15'-2" (4623) 5'-11" (1803) (4851) (3) A hoist beam (by KONE) is required for installation (by others). Dimension H reflects clear under hoist beam. (4) If occupied space exists below(10) the hoistway, consult your KONE Sales Professional. CONTROL SPACE (J) (K) (L) (5) A ll dimensions are based on an 8'-0" (2438 mm) cab with a 7'-0" (2134 mm) door. Alternate car and door heights are Visit kone.us for the latest project-specific CONTROLLER SPACE WIDTH (mm) DEPTH (mm) DOOR WIDTH (mm) CAPACITY (kg) H . available, but will affect LBS. dimension details, CAD drawings, BIM models, CSI (6) I f an Emergency Battery Device Professional for further details 2500 to 5000 AIA (EBD) is required, please contact your KONE Sales (10) (10) specifications, electrical data, reaction Integral or Remote Cabinet 4'-4" (1321) 1'-8" (508) 4'-0" (1219)(10) (1134 toJ 2268) and L . loads and building access requirements. regarding dimensions 2500 to 5000 AIAProfessional regarding local code variations when utilizing the integral and remote (7) C ontact your local KONE Sales Dimension (B) Adjacent or Remote Room 5'-0" (1524) 3'-0" (914)(10) (1134 to 2268) closet options. Notes (8) If utilizing KONE Destination or KONE Access™, contact your local KONE Sales Professional regarding control space (1) Smaller pit and overhead dimensions may berequirements. available per specific applications. (6) If an Emergency Battery Device (EBD) is required, please contact your KONE size Contact your KONE Sales Professional for further information. Sales Professional for further details regarding dimensions (J) and (L). (9) 4'-0" (1219 mm) door width also available. (2) Buffer service platforms are required when pit depth exceeds 8'-6" (2590 mm). (7) Contact your local KONE Sales Professional regarding local code variations (10) If IBC 2018 ASME A17.1-2019/CSA B44-19when code is applicable, contactand your local sales utilizing the integral remote closetprofessional options. for controller (3) A hoist beam (by KONE) is required for installation (byorothers). Dimension (H) space configurations. reflects clear under hoist beam. (8) If utilizing KONE destination control system or KONE Access™, contact your local KONE Sales Professional regarding control space size requirements. (4) If occupied space exists below the hoistway, consult your KONE Sales Professional. (9) 4’-0” (1219 mm) door width also available. (5) All dimensions are based on an 8'-0" (2438 mm) cab with a 7'-0" (2134 mm) (10) If IBC 2018 or ASME A17.1-2019/CSA B44-19 code is applicable, contact your door. Alternate car and door heights are available, but will affect dimension (H). local sales professional for controller space configurations. Plan views A C Plan Views E KONE MonoSpace 700 DX Section view (3) Section View (A) (C) (E) (1) (5) H D B K E F G (3) (D) (B) L J (1) (5) (6) Integral Control Closet (standard) (H) (F) G (1) (2) I (K) (E) (L) (J) (6) J (6) Integrated Control Closet (4) (standard) K (K) L J (L) (6) (J) (G) TRAVEL B Remote Control Closet (6) (option 1) Remote Control Closet TRAVEL (option 1) L (6) (J) (G) Adjacent or Remote Control Room (option 2) (1) (2) (I) I Adjacent or Remote Control Room (option 2) (4) (B) (L) For configuration guidance or more information scan this code or visit our website to get in touch with a KONE Sales Professional: kone.us/ms700dx KONE kone.us Copyright © 2022 KONE Inc. This publication is for general informational purposes only. KONE Inc. reserves the right to alter the product design and specifications without prior notice. Minor differences between printed and actual colors may exist. KONE MonoSpace® DX and KONE Access™ are registered trademarks or trademarks of KONE Corporation. SF2983 - Rev 0422 Printed in the U.S. KONE MINISPACE KONE MINISPACEDXDX ™ ™ CONFIGUR ATIONS & DIMENSIONS CONFIGUR ATIONS & DIMENSIONS Max Travel 63 D E Clear Overhead I 2000 (907) and Pit Depth J PASSENGER 6'-8" (2032) 6'-81⁄2 " (2045) 4'-31⁄4 " (1302) 3'-6" (1067) 3000 (1361) SSP-CO 8'-4" (2540) 8'-8" (2642) 7'-2" (2184) 6'-81⁄2 " (2045) 4'-91⁄4 " (1454) 3'-6" (1067) 3500 (1588)(A) SSP-CO 8'-4" (2540) (A) SEISMIC 8'-8" (2642) (B) 7'-10" (2388) (C)6'-8 ⁄ " (2045) 1 5'-5(D) ⁄4 " (1657) 3'-6" (1067) (E) 4000 (1814) CO OPENING HOISTWAY 4000 (1814) TYPE† WIDTH (mm) 2SP 4500 (2041) 2SP SSP 7'-4" (2235) 5000 (2268) 2SP SSP / CO 8'-4" (2540) 5000 AIA (2268) 2SP SSP / CO 8'-4" (2540) 2000 (907) SSP SSP / CO 2500 (1134) 8'-4" (2540) SSP-CO 9'-4" (2845) HOISTWAY 8'-1" WIDTH(2464) (mm) 8'-1" (2464) 7'-8" (2337) 8'-1" (2464) 8'-8" (2642) 8'-8" (2642) 8'-8" (2642) 8'-4" (2540) 8'-8" 9'-4" (2642) (2845) 9'-8" (2946) 7'-10" (2388) 7'-81⁄2 " (2350) HOISTWAY INTERIOR 8'-4" (2540) DEPTH (mm) 9'-2" (2794)WIDTH 5'-8 (mm)1⁄2 " (1740) 8'-4" (2540) 9'-8" (2946) 5'-81⁄2 " (1740) 6'-10" (2083) 5'-8½" (1740) 8'-4" (2540) 10'-2" (3099) 5'-81⁄2 " (1740) 6'-8" (2032) 6'-8½" (2045) 8'-11" (2718) 10'-73 ⁄4 " (3245) 5'-81⁄2 " (1740) 7'-2" (2184) 1 6'-8½" (2045) 8'-8" (2642) 6'-3 ⁄4 " (1911) 5'-8 1⁄2 " (1740) 1 6'-8½" 6'-8 (2045) 9'-8" 7'-10" (2946)(2388) 6'-3 1⁄4 " (1911) ⁄2 " (2045) 5'-51⁄4 " (1657) INTERIOR 7'-6"(mm) (2286) DEPTH SERVICE 8'-8" (2642) Front Opening SERVICE 5000 AIA (2268) 4 8'-4" (2540) PASSENGER 4000 (1814) Entrance Height G 4000 (1814) 7, 8 or 9 ft. 4500 (2041) (2134, 2438 or 5000 (2268) 2743 mm) 1 2 SSP-CO Front & Reverse Opening PASSENGER C 2500 (1134) 1 2 8'-0" (2438) 4'-3¼" (1302) 8'-73 ⁄4 " (2635) 4'-3¼" (1302) 9'-0" (2743) 4'-9¼"3 (1454) 4'-3 ⁄4 " (1314) 5'-5¼" 4'-33 ⁄(1657) 4 " (1314) 4'-0" (1219) DOOR 4'-0" (1219) WIDTH (mm) 4'-0" (1219) 3'-0" (914) 4'-6" (1372)(9) 3'-6" (1067) 4'-6" (1372)(9) 3'-6" (1067) 3'-0" (914) 3'-6" (1067) 3'-6" (1067) CO 9'-4" (2845) 3000 (1361) SSP-CO 9'-8" 9'-4" (2946) (2845) 1 7'-8½" 6'-8 (2350) 9'-8" 7'-10" (2946)(2388) 6'-9 1⁄4 " (2064) ⁄2 " (2045) 5'-5¼" 4'-93 ⁄(1657) 4 " (1467) 4'-0" (1219) 3'-6" (1067) 2SP 3500 (1588) SSP-CO 8'-1" (2464) 4000 (1814) CO 8'-1" (2464) 4000 (1814) 2SP 8'-1" (2464) 4500 (2041) 2SP 8'-8" (2642) 5000 (2268) 2SP (2540) 2SP 5000 AIA8'-4" (2268) 9'-4" (2540) (2845) 8'-4" 10'-4" (3150) 8'-4" (2540) 8'-1" (2464) 8'-4" (2540) 8'-1" (2464) 8'-11" (2718) 8'-1" (2464) 8'-8" (2642) (2642) 1 1 3 9'-8" (2946) ⁄2 " (2045) 7'-6" 5'-5(2286) ⁄4 " (1670) 9'-2" (2794)7'-5 ⁄4 " (2267) 5'-8½" 6'-8 (1740) 10'-8" (3251) 7'-5 1⁄4 " (2267) 7'-8 1⁄2 " (2350) 5'-53 ⁄4 " (1670) 9'-8" (2946) 5'-8½" (1740) 8'-0" (2438) 8'-4" (2540) 10'-1" (3073) 5'-8 1⁄2 " (1740) 7'-6 1⁄2 " (2299) 10'-2" (3099) 5'-8½" (1740) 8'-7¾"1 (2635) 8'-4" (2540) 10'-7" (3226) 5'-8 1⁄2 " (1740) 8'-0 ⁄2 " (2451) 10'-7¾" (3245) 3 5'-8½" (1740) 9'-0" (2743) 8'-4" (2540) 11'-2 ⁄4 " (3423) 5'-8 1⁄2 " (1740) 8'-81 ⁄4 " (2648) 1 5'-8½" 5'-8 (1740) 9'-0" 6'-3¼" (2743)(1911) 11'-63 ⁄4 " (3524) ⁄2 " (1740) 4'-3¾" 9'-0"(1314) (2743) 3'-6" (1067) 4'-0" (1219) 4'-0" (1219) 4'-0" (1219) 4'-0" (1219) (9) 4'-6" (1372) 4'-0" (1219) (9) 4'-6" (1372) 4'-6" (1372)(9) (9) (914) 4'-6"3'-0" (1372) 2SP 2SP SERVICE 2000 (907) F (1134) Car Height2500 8, 9 or 10 ft. 3000 (1361) (2438, 2743 or 3500 (1588) 3048 mm) PASSENGER B 1 Speed 200, 350, 400, 500, 700, 1000 fpm CAPACITY (1.00, 1.78, 2.00, LBS. (kg) 2.54, 3.56, 5.00 m/s) FRONT OPENING SEISMIC Speed (F) Height (G)INTERIOR ClearDOOR Overhead (I) CAPACITY OPENING HOISTWAYCar Height HOISTWAY HOISTWAY Entrance INTERIOR lbs. (kg) WIDTH (mm) WIDTH (mm) DEPTH (mm) and WIDTH (mm) (J) 200, 350, 400, 500, 700,TYPE 1000 fpm 8, 9 or 10 ft.(mm) DEPTH (mm) 7, 8WIDTH or 9 ft. Pit Depth 2000 (907) SSP 7'-4" (2235) 7'-8" (2337) 6'-10" (2083) 5'-8 ⁄ " (1740) 4'-3 ⁄ " (1302) 3'-0" (914) (1.00, 1.78, 2.00, 2.54, 3.56, 5.00 m/s) (2438, 2743 or 3048 mm) (2134, 2438 or 2743 mm) Landings MaxMax Landings 63 FRONT & REVERSE OPENING A A ft. (180 m) Max590 Travel 590 ft. (180 m) 2SP SSP 2500 (1134) SSP / CO 9'-4" (2845) 9'-8" (2946) 6'-3¼" (1911) 6'-8½" (2045) 4'-3¾" (1314) 3'-6" (1067) 3000 (1361) SSP / CO 9'-4" (2845) 9'-8" (2946) 6'-9¼" (2064) 6'-8½" (2045) 4'-9¾" (1467) 3'-6" (1067) 3500 (1588) SSP / CO 9'-4" (2845) 9'-8" (2946) 10'-4" (3150) PIT DEPTH 8'-1"(mm) (2464) 2SP 2000 8'-1" (2464) – (907) – 2SP 8'-1" (2464) 2500-3500 5'-3" 2SP 8'-8" (2642) (1134-1588) (1600) 10'-8" (3251) CLEAR PIT OVERHD DEPTH (mm) 8'-4" (2540) (mm) 8'-4" (2540) – – – – 8'-4" (2540) 14'-1" 5'-6" 9'-0" (2743) (4292) (1676) CLEAR OVERHEAD I AND PIT DEPTH J CO CAPACITY 2SP lbs. (kg) SERVICE 4000 (1814) Visit kone.us for the latest project-specific details, BIM 4000 (1814) models, CAD 4500 drawings, (2041) specifications, electrical data, 5000 (2268) reaction loads and building 5000 AIA (2268) access requirements. 200 FPM 1.00 m/s 350 FPM 400 FPM 7'-5¼" (2267) 6'-8½" (2045) 1.78 m/s 2.03 m/s 14'-1" † SSP = Single Speed Side Opening / CO = Single Speed 4000 Center Opening /5-'3" 2SP = Two Speed Side Opening 5'-6" (1814) (1600) (4292) (1676) 4500 CLEAR OVERHEAD (I) AND PIT DEPTH (J) (2041) 5000 CAPACITY LBS. (kg) 2000 (907) 2500-3500 (1134-1588) 200 FPM (1.00 M/S) (2268) PIT DEPTH (mm) — 5-'3" (1600) 14'-7" (4445) 5'-6" (1676) 5-'3" 14'-7" 5'-6" (1.78 M/S)(1676) (1600)350 FPM (4445) 5000 AIA 5'-6" 14'-9" 5'-8" CLEAR OVERHD (1676) PIT DEPTH (4496) CLEAR OVERHD (2268) (1727) (mm) (mm) (mm) — Notes — — 7'-5¼" (2267) CLEAR PIT OVERHD DEPTH 10'-1" (3073) (mm) (mm) – 10'-7" (3226) – – – 11'-2¾" (3423) 14'-7" 6'-0" 11'-6¾" (3524) (4445) (1829) 500 FPM 700 FPM (1,2,3) 5'-5¾" (1670) 3'-6" (1067) 2.54 m/s 3.56 m/s (1,2,3) 7'-8½" (2350) CLEAR PIT OVERHD DEPTH 5'-8½" (mm) (1740) (mm) 5'-8½" (1740) – – – – 5'-8½" (1740) 14'-11" 6'-10" 5'-8½" (1740) (4547) (2083) 5'-5¾" (1670) CLEAR OVERHD 7'-6½" (mm)(2299) 8'-0½" – (2451) – 8'-8¼" (2648) 15'-8" 9'-0" (2743) (4775) 4'-0" (1219) CLEAR OVERHD 4'-0"(mm) (1219) 4'-0"21'-0" (1219) 10'-6" (3200) (6401) 4'-6" (1372)(9) 10'-6" 21'-0" (9) (1372) (3200) 4'-6"(6401) PIT DEPTH (mm) 14'-7" (4445) 6'-0" (1829) 14'-11" (4547) 6'-10" (2083) 15'-8" (4775) – – – – 15'-1" (4597) 6'-0" (1829) 15'-5" (4953) 6'-10" (2083) 16'-2" (4928) – – – – 15'-1" 6'-0" 400 FPM (2.03 M/S) (4597) (1829) 15'-1" PIT(4597) DEPTH (mm) — 15'-5" 6'-10" 16'-2" (2.54 M/S) (4953) 500 FPM (2083) (4928) 7'-2" 16'-2" 7'-2" 16'-2" CLEAR OVERHD (4928) PIT DEPTH(2184) CLEAR OVERHD (2184) (4928) (mm) (mm) (mm) — — — –700 FPM (1,2,3) – – – 3.56 m/s (1,2,3) – PIT DEPTH – (mm) – CLEAR – OVERHD (mm) 10'-6" (3200) 21'-0" (6401) 5'-3" (1600)(1) 14'-1" (4292) above 5'-6"1000 (1676)fpm14'-7" (4547) 6'-10" (2083) 15'-8" Sales (4775)Professional 10'-6" (3200) 21'-0" (6401) For speeds (5.00(4445) m/s) or 6'-0" travel(1829) above 14'-11" 590' (180 m) contact your KONE for design and planning assistance. 14'-1" (4292) 5'-6" (1676) 4000 (1814) 5'-3" (1600) 4500 (2041) (2)For 700 fpm (3.56 m/s) and 1000 fpm (5.00 m/s) front front opening passenger configurations add 2" (51 mm) to the 5'-3" (1600) 14'-7" (4445) 5'-6" (1676) 15'-1" (4597) 6'-0" (1829) 15'-5" (4953) 6'-10" (2083) 16'-2" (4928) — — hoistway depth B . 5000 (2268) 5'-3" (1600)(3) 14'-7" (4445) is based 5'-6" (1676) 15'-1" (4597) 6'-0"For (1829) 15'-5" (4953) applications, 6'-10" (2083) please 16'-2" (4928) — Information upon chain compensation. rope compensation consult your KONE Sales 5000 AIA (2268) 5'-6" (1676) Professional. 14'-9" (4496) 5'-8" (1727) 14'-7" (4445) 15'-1" (4597) 6'-0" (1829) 7'-2" (2184) 14'-11" (4547) 16'-2" (4928) 6'-10" (2083) 7'-2" (2184) 15'-8" (4775) 16'-2" (4928) — — — — — (4) All dimensions are based on an 8'-0" (2,438 mm) cab with a 7'-0" (2,134 mm) door. Alternate car and door heights are available, but will affect dimension I . Visit kone.us for the latest project-specific details, BIM models, CAD drawings, (5) If occupied space exists below the hoistway, consult your KONE Sales Professional. specifications, electrical data, reaction loads and building access requirements. (6) Information is based upon structural machine room floor slabs. For machine beam applications, please consult your KONE Sales Professional. Notes (7) Machine room height of 8'-0" (2,438 mm) is measured from the machine room floor surface to underside of the lowest (1) For speeds above 1000 fpm (5.00 m/s) or travel above (180 m) contact (6) Information based uponfor structural obstruction above 590' the machine KONE SalesisProfessional details.machine room floor slabs. For machine H . Consult yourbeam your KONE Sales Professional for design and planning assistance. applications, please consult your KONE Sales Professional. For(5.00 service applications the machine room is not the hoistway requires additional 7" (178from mm)the of width. (2) For 700 fpm (3.56 m/s) and 1000(8) fpm m/s) front opening passenger (7) centered Machineonroom height ofand 8'-0" (2,438anmm) is measured machine additional 7" (178 counterweight side. Consult your Salesobstruction Professional above for details. configurations add 2" (51 mm) to theThe hoistway depth (B). mm) should be added to the room floor surface to underside of KONE the lowest the machine (H). Consult your KONE Sales Professional for details. (3) Information is based upon chain compensation. rope compensation (9) 4’-0” (1219For mm) door width also available. applications, please consult your KONE Sales Professional. (8) For service applications the machine room is not centered on the hoistway and requires an additional 7" (178 mm) of width. The additional 7" (178 (4) All dimensions are based on an 8'-0" (2,438 mm) cab with a 7'-0" (2,134 mm) mm) should be added to the counterweight side. Consult your KONE Sales door. Alternate car and door heights are available, but will affect dimension (I). Professional for details. (5) If occupied space exists below the hoistway, consult your KONE Sales (9) 4’-0” (1219 mm) door width also available. Professional. Plan Views Section view H KONE MiniSpace DX Section View E Plan views (8) (2) B (E) D (H) (8) I (4) F (2) G (B) (D) E C A (6) (G) (F) (I) (4) Machine Room (E) (C) (A) TRAVEL (6) G Machine Room B J (G) TRAVEL (B) (5) A (9) (J) (5) (A) (8) For configuration guidance or more information scan this code or visit our website to get in touch with a KONE Sales Professional: kone.us/minisdx KONE kone.us Copyright © 2022 KONE Inc. This publication is for general informational purposes only. KONE Inc. reserves the right to alter the product design and specifications without prior notice. Minor differences between printed and actual colors may exist. KONE MiniSpace™ DX is a trademark of KONE Corporation. SF2985 - Rev 0422 Printed in the U.S. AN INTRODUCTION TO ESCALATORS AND AUTOWALKS Definitions and components An escalator is a moving staircase for transporting people between floors of a building. It is generally agreed that an escalator is the most efficient means to move large numbers of people between floors. Item Component Item Component 1 Handrail 11 Transition radii 2 Skirting 12 Truss 3 Steps/pallets 13 Side cladding 4 Decking 14 Step chain 6 5 Balustrade 15 Tracks 2 6 Horizontal steps/pallets 16 Return station 4 7 Drive station 17 Access cover plate 5 8 Controller 18 Newel 9 Front plate 10 Handrail drive 1 18 9 17 7 8 13 16 14 3 11 10 15 12 A horizontal autowalk is a conveyor belt that transports people horizontally. Autowalks are generally provided in areas where people need to walk long distances with luggage, baggage carts or shopping carts. An autowalk is generally flat, but can be slightly inclined. 1 5 4 9 16 18 14 17 12 7 15 2 8 3 10 KONE ESCALATORS AND AUTOWALKS n Quiet, smooth operation n Eco-efficient and economical n Small installation dimensions n High levels of reliability n Design options to match the image of your building KONE TransitMaster™ 210 ApplicationSupermarkets, department stores, shopping centers Type Escalator Rise Up to 52' 5" (16 m) Nominal Step Width 24", 32", 40" (600, 800, 1000 mm) Balustrade Glass or solid Speed 100 fpm (.50 m/s) The KONE TransitMaster 210 is a commercial escalator targeted primarily toward the retail segment – supermarkets, department stores and shopping centers. It is designed, from both a technical and visual point of view, to fulfill customer requirements in various target segments. KONE TransitMaster™ 220 ApplicationStadiums, Arenas, Convention Centers, Airports, Light Rail Type Escalator Rise Up to 49' 2" (15 m) Nominal Step Width 24", 32", 40" (600, 800, 1000 mm) Balustrade Glass or Solid Speed 100 fpm (0.5 m/s) The KONE TransitMaster 220 is a heavy-duty escalator targeted primarily towards the Infrastructure segment, and in particular mid to high duty applications. This segment covers airports, rail and transportation systems as well as other transit centers. Airports and rail systems are the most common target buildings for this solution. KONE TransitMaster™ 180 ApplicationHeavy traffic, public transportation, metro Type Escalator Nominal Step Width 24", 32", 40" (600, 800, 1000 mm) Balustrade Glass or solid Speed 100 fpm (.50 m/s) The versatile KONE TransitMaster 180 escalator is ideal for new installations and is specifically designed to meet the demanding needs of public transportation all the way up to the demanding requirements of mass transit airport and railway systems. Our heavy-duty escalators are designed to enable the seamless flow of large numbers of passengers. KONE TransitMaster™ 165/185 ApplicationHeavy traffic, airports, public transportation, metro Type Autowalk Length Per requirements Nominal Pallet Width32", 40", 48", 56" (800, 1000, 1200, 1400 mm) Balustrade Glass or solid Speed 100 or 130 fpm (.50 or .66 m/s) The KONE Autowalk achieves the perfect balance between form and function. An attractive welcome area invites passengers to take an uncommonly smooth and quiet ride, while offering options to meet your architectural vision. KONE EcoMod® ApplicationRetail, airports, stadiums, hotels, leisure venues Type Complete escalator modernization Nominal Step Width 24", 32", 40" (600, 800, 1000 mm) Balustrade Glass or solid Speed 100 fpm (.50 m/s) For the latest product information and interactive design tools, visit kone.us The KONE EcoMod escalator modernization solution offers an innovative and systematic approach to replacing the entire workings of your escalators and delivering brand new technology without expensive, disruptive truss removal. KONE TRANSITMASTER 210 ™ Commercial Escalator Product With over 100 years of experience in the elevator and escalator industry, KONE is your trusted partner, dedicated to ensuring smooth People Flow™. KONE’s reliable escalator solutions use proven technology and is designed to meet the needs of demanding commercial environments, such as supermarkets, department stores and shopping centers. It is also suitable for hotels, offices, hospitals, leisure facilities and airports. The main benefits of the TransitMaster 210 Main Characteristics of the TransitMaster 210 Market Segment Maximum rise n n n Attractive design helps to create a pleasant ambiance in the building All visual options can be customized to fit the customers overall building design Harmonized look and feel across the product portfolio n n LED lighting solutions support increase passenger safety Serves the customers building throughout its entire lifecycle Smart Technology: KONE 24/7 Connected Services. up to 52' 2" (16 m) Inclination 30° Transition radii Lower Radius: 1.0 or 2.0 (m) Upper Radius: 1.0, 1.5, 2.7 (m) Speed 100 fpm (0.5 m/s) Step width 24", 32", 40" (600, 800, 1000 mm) Step load 192 lbs. / step Horizontal steps Handrail Type Balustrade type n Retail, Office, Medical, Small Airports Balustrade glass thickness Balustrade height 2/2 or 3/3 C-Type Glass, Solid stainless steel inclined 3/8" (10mm) and 1/2" (12mm) 40" (1000 mm) Skirt material Black teflon Front plate material Black plastic Environment Indoor / Outdoor L oad profile Overall load profile 42% 12h/day; 7 days/week: 2% time at 100% load 35% time at 50% load 63% time at 25% load KONE TransitMaster 210 Configuration & Dimensions KONE TRANSITMASTER 210 BASIC DATA Inclination Level Steps Radii Maximum Vertical Rise Nominal Step Width Balustrade Balustrade height Speed Electrification Chain Type Handrail Environment 30 degrees 2 or 3 Level Steps Lower Radius: 1.0 or 2.0 (meters) Upper Radius: 1.0, 1.5, 2.7 (meters) 52' 5" (16 m) 24", 32" and 40" (600,800, 1000 mm) Glass and solid incline 3'-3' 3⁄8" (1000 mm) 100 FPM (0.5 m/s) NFPA 70 and CSA-C22.1 Inside Chain Roller C-Type Indoor/ Outdoor DIMENSION BB/EE (UPPER HEAD) FOR NON-SEISMIC BB W1: Step Width H: Rise Level steps - up radius / low radius (m) EE 2-1.0/1.0 2-1.5/1.0 3-1.5/1.0 3-2.7/2.0 8' 2 ⁄16" - 15' 9" (2500 mm - 4800 mm) 8' ⁄8" (2455 mm) 8' 5 ⁄16" (2589 mm) 9' 8 ⁄8" (2949 mm) 10' 4 15⁄16" (3173 mm) 1' 9 1⁄16" (535 mm) 15' 9" - 31' 9 7⁄8" (4801 mm - 9700 mm) 8' 3 7⁄16" (2525 mm) 8' 8 11⁄16" (2659 mm) 9' 10 7⁄8" (3019 mm) 10' 4 15⁄16" (3243 mm) 1' 11 13⁄16" (605 mm) 31' 9 15⁄16" - 52' 5 15⁄16" (9701 mm - 16000 mm) 9' 8 5⁄16" (2955 mm) 10' 1 5⁄8" (3089 mm) 11' 3 13⁄16" (3449 mm) 12' 5⁄8" (3673 mm) 3' 4 3⁄4" (1035 mm) 32" (800 mm) 8' 2 7⁄16" - 34' 5 3⁄8" (2500 mm - 10500 mm) 8' 7 3⁄8" (2625 mm) 9' 5⁄8" (2759 mm) 10' 2 13⁄16" (3119 mm) 10' 11 5⁄8" (3343 mm) 2' 3 3⁄4" (705 mm) 24" (600 mm) 8' 2 7⁄16" - 39' 4 7⁄16" (2500 mm - 12000 mm) 9' 8 5⁄16" (2955 mm) 10' 1 5⁄8" (3089 mm) 11' 3 13⁄16" (3449 mm) 12' 5⁄8" (3673 mm) 3' 4 3⁄4" (1035 mm) 7 40" (1000 mm) 5 15 1 DIMENSION AA/DD (LOWER HEAD) FOR NON-SEISMIC AA W1: Step Width Truss/comb heating Level steps - up radius / low radius (m) DD 2-1.0/1.0 2-1.5/1.0 3-1.5/1.0 3-2.7/2.0 40" (1000 mm) Without/With 7' 3 5⁄8" (2226 mm) 7' 3 5⁄8" (2226 mm) 8' 3 3⁄4" (2534 mm) 9' 1 5⁄16" (2777 mm) 1' 9 1⁄16" (535 mm) 32"/24" (800 mm / 600 mm) Without 7' 3 5⁄8" (2226 mm) 7' 3 5⁄8" (2226 mm) 8' 3 3⁄4 " (2534 mm) 9' 1 5⁄16" (2777 mm) 1' 9 1⁄16" (535 mm) 32"/24" (800 mm / 600 mm) With 8' 5 7⁄16" (2576 mm) 8' 5 7⁄16" (2576 mm) 9' 5 9⁄16" (2884 mm) 10' 3 1⁄8" (3127 mm) 2' 10 13⁄16" (885 mm) HA HB CC FF HL HU 3' 3" (990 mm) 3’ 1” (940 mm) 1.73205 x H AA+7' 1⁄2' (AA+2139 mm) 3' 8 1⁄2" (1130 mm) 3' 8 1⁄2" (1130 mm) KONE TransitMaster 210 Configuration & Dimensions R KEY WIDTH DIMENSIONS W1: Step width 3'-3' 1⁄2" (1000 mm) 2' - 7' 1⁄2" (800 mm) 1'-11' 1⁄2" (600 mm) W2: Handrail centerline distance 4'-1' 11⁄16" (1262 mm) 3'-5 7⁄8" (1064 mm) 2'-10' 1⁄8" (866 mm) W4: Width of truss 4'-11' 7⁄16 (1510 mm) 4' - 3' 5⁄8 (1312 mm) 3' - 7' 7⁄8" (1114 mm) W5: Width of finished escalator 5'- 3' 1⁄16" (1602 mm) 4' - 7' 1⁄4" (1404 mm) 3'-11' 1⁄2" (1206 mm) W6: Width of pit 5'- 5' 1⁄16" (1650 mm) 4' - 9' 3⁄16" (1450 mm) 4' - 1' 5⁄16" (1250 mm) EXTENSION BY SEISMIC TYPE Seismic end support type Increase for AA&BB&DD&EE Type A 0' 1 3⁄4" (45 mm) Type B 0' 1 3⁄4" (45 mm) Type C 0' 3 1⁄8" (79 mm) Type D 0' 4 1⁄16" (103 mm) Type E 0' 5 5⁄8" (146 mm) Type F 0' 8 1⁄16" (205 mm) Type G 0' 10 5⁄16" (262 mm) Type H 1' 5⁄16" (313 mm) Notes (1) Details represent standard KONE escalator configurations. Please consult your sales R professional to review all possible deviations. Visit KONE.us for the latest project-specific details, electrical data, reaction loads, planner tools and building access requirements. *All drawings are for illustration purposes only. KONE TRANSITMASTER 220 ™ Public Transportation Escalator Product With over 100 years of experience in the elevator and escalator industry, KONE is your trusted partner, dedicated to ensuring smooth People Flow™. KONE’s reliable escalator solutions use proven technology and is designed to meet the needs of demanding public transportation environments, such as airports, rail and transportation systems as well as other transit centers. The main benefits of the TransitMaster 220 Main Characteristics of the TransitMaster 220 Market Segment Maximum rise n n n Extensive and flexible offering to match any need and environment Unconditional safety and reliability even under heavy People Flow Optimized total cost of ownership to meet the needs of the customer n n Optional features to offer environmentally friendly operation Elegant and modern design with numerous lighting options Smart Technology: KONE 24/7 Connected Services. up to 49' 2" (15 m) Inclination 30° Transition radii Lower Radius: 1.5/1.0 (m) Upper Radius: 2.7/2.0 (m) Speed 100 fpm (0.5 m/s) Step width 24", 32", 40" (600, 800, 1000 mm) Step load 264 lbs. / step Step chain Inside roller (75 mm x 23.5 mm) Horizontal steps Handrail Type n Stadiums, Arenas, Convention Centers, Airports, Light Rail Balustrade type Balustrade glass thickness Balustrade height Skirt material Front plate material 2/2 or 3/3 V-Type Glass, Solid inclined balustrade 3/8" (10 mm) and 1/2" (12 mm) 40" (1000 mm) Stainless Steel Stainless Steel Environment Indoor / Outdoor L oad profile Overall load profile 54% 20h/day; 7 days/week 10% time at 100% load 40% time at 50% load 50% time at 25% load KONE TransitMaster 220 Configuration & Dimensions KONE TRANSITMASTER 210 BASIC DATA Inclination Level Steps Radii Maximum Vertical Rise Nominal Step Width Balustrade Balustrade height Speed Electrification Chain Type Handrail Environment 30 degrees 2 or 3 Level Steps Lower Radius: 1.5/1.0 (meters) Upper Radius: 2.7/2.0 (meters) 49' 2" (15 m) 24", 32" and 40" (600,800, 1000 mm) Glass and solid incline 3'-3' 3⁄8" (1000 mm) 100 FPM (0.5 m/s) NFPA 70 and CSA-C22.1 Inside Chain Roller V-Type Indoor/ Outdoor DIMENSION BB/EE (UPPER HEAD) FOR NON-SEISMIC BB W1: Step Width H: Rise Level steps - up radius / low radius (m) EE 2-1.0/1.0 2-1.5/1.0 3-1.5/1.0 3-2.7/2.0 8' 2 ⁄16"- 11' 9 ⁄4" (2500 mm - 3600 mm) 5 8' ⁄8" (2455 mm) 8' 5 ⁄16" (2589 mm) 9' 8 ⁄8" (2949 mm) 10' 4 15⁄16" (3173 mm) 1' 9 1⁄16" (535 mm) 11' 9 3⁄4" - 23' 11 3⁄8" (3601 mm - 7300 mm) 8' 3 7⁄16" (2525 mm) 8' 8 11⁄16" (2659 mm) 9' 10 7⁄8" (3019 mm) 10' 7 11⁄16" (3243 mm) 1' 11 13⁄16" (605 mm) 23' 11 7⁄16" - 52' 5 15⁄16" (7301 mm - 16000 mm) 9' 8 5⁄16" (2955 mm) 10' 1 5⁄8" (3089 mm) 11' 3 13⁄16" (3449 mm) 12' 5⁄8" (3673 mm) 3' 4 3⁄4" (1035 mm) 32" (800 mm) 8' 2 7⁄16" - 27' 10 5⁄8" (2500 mm - 8500 mm) 8' 7 3⁄8" (2625 mm) 9' 5⁄8" (2759 mm) 10' 2 13⁄16" (3119 mm) 10' 11 5⁄8" (3343 mm) 2' 3 3⁄4" (705 mm) 24" (600 mm) 8' 2 7⁄16" - 34' 5 3⁄8" (2500 mm - 10500 mm) 9' 8 5⁄16" (2955 mm) 10' 1 5⁄8" (3089 mm) 11' 3 13⁄16" (3449 mm) 12' 5⁄8" (3673 mm) 3' 4 3⁄4" (1035 mm) 7 40" (1000 mm) 3 15 1 DIMENSION AA/DD (LOWER HEAD) FOR NON-SEISMIC AA W1: Step Width Truss/comb heating Level steps - up radius / low radius (m) DD 2-1.0/1.0 2-1.5/1.0 3-1.5/1.0 3-2.7/2.0 40" (1000 mm) Without/With 7' 3 5⁄8" (2226 mm) 7' 3 5⁄8" (2226 mm) 8' 3 3⁄4" (2534 mm) 9' 1 5⁄16" (2777 mm) 1' 9 1⁄16" (535 mm) 32"/24" (800 mm / 600 mm) Without 7' 3 5⁄8" (2226 mm) 7' 3 5⁄8" (2226 mm) 8' 3 3⁄4 " (2534 mm) 9' 1 5⁄16" (2777 mm) 1' 9 1⁄16" (535 mm) 32"/24" (800 mm / 600 mm) With 8' 5 7⁄16" (2576 mm) 8' 5 7⁄16" (2576 mm) 9' 5 9⁄16" (2884 mm) 10' 3 1⁄8" (3127 mm) 2' 10 13⁄16" (885 mm) HA HB CC FF HL HU 3' 3" (990 mm) 3' 1" (940 mm) 1.73205 x H AA+7' 1⁄2' (AA+2139 mm) 3' 8 1⁄2" (1130 mm) 3' 8 1⁄2" (1130 mm) KONE TransitMaster 220 Configuration & Dimensions R KEY WIDTH DIMENSIONS W1: Step width 3'-3' 1⁄2" (1000 mm) 2' - 7' 1⁄2" (800 mm) 1'-11' 1⁄2" (600 mm) W2: Handrail centerline distance 4'-1' 11⁄16" (1262 mm) 3'-5 7⁄8" (1064 mm) 2'-10' 1⁄8" (866 mm) W4: Width of truss 4'-11' 7⁄16 (1510 mm) 4' - 3' 5⁄8 (1312 mm) 3' - 7' 7⁄8" (1114 mm) W5: Width of finished escalator 5'- 3' 1⁄16" (1602 mm) 4' - 7' 1⁄4" (1404 mm) 3'-11' 1⁄2" (1206 mm) W6: Width of pit 5'- 5' 1⁄16" (1650 mm) 4' - 9' 3⁄16" (1450 mm) 4' - 1' 5⁄16" (1250 mm) EXTENSION BY SEISMIC TYPE Seismic end support type Increase for AA&BB&DD&EE Type A 0' 1 3⁄4" (45 mm) Type B 0' 1 3⁄4" (45 mm) Type C 0' 3 1⁄8" (79 mm) Type D 0' 4 1⁄16" (103 mm) Type E 0' 5 5⁄8" (146 mm) Type F 0' 8 1⁄16" (205 mm) Type G 0' 10 5⁄16" (262 mm) Type H 1' 5⁄16" (313 mm) Notes (1) Details represent standard KONE escalator configurations. Please consult your sales R professional to review all possible deviations. Visit KONE.us for the latest project-specific details, electrical data, reaction loads, planner tools and building access requirements. *All drawings are for illustration purposes only. KONE TRANSITMASTER 180 ™ KONE TransitMaster 180 escalators are available in two step widths, glass or solid balustrades and many other available options and finishes. The robust design, coupled with excellence in manufacturing and service help make KONE TransitMaster 180 a great solution for public transportation applications such as railway or metro stations. Detail 1 Detail 2 KONE TransitMaster 180 – Basic data Inclination 30 degrees Level Steps 2-4 Level Steps Radii 4'-11" or 8'-10" (1.5 or 2.7 m) Upper Radius Maximum Vertical Rise 60'-0" (18 m) Step Width 24", 32", 40" (600, 800, 1000 mm) Balustrade Glass or Solid Inclined Balustrade Height 3'-33⁄8" (1000 mm) Speed 100 fpm (0.5 m/s) Electrification NFPA 70 and CSA-C22.1 Chain Type Outside Chain Roller Handrail Environment V-type Indoor / Outdoor Notes (1) Details represent standard KONE escalator configurations. Please consult your Sales Professional to review all possible deviations. (2) For detailed options and dimensional design data, please contact a KONE Professional. *All drawings are for illustration purposes only. Visit kone.us for the latest project-specific details, electrical data, reaction loads, architectural toolbox and building access requirements. KONE TRANSITMASTER™ 165/185 AUTOWALKS Public Transportation Autowalk Product Well designed and manufactured autowalks are a must for today’s highly demanding public areas. They are key to ensuring the smooth, efficient and safe flow of people traveling in airport environments. We offer two different types of solutions for your facility. The main benefits of KONE TransitMaster 165/185 n Safety and reliability n High quality in terms of technical performance and visual appearance n Optimized total cost of ownership n Flexible offering to cover the wide range of needs of the segment n Elegant, modern and harmonized design Main Characteristics of the TransitMaster 165/185 Inclination Maximum length Speed Pallet width Balustrade type Balustrade height Handrail type Pallet chains TransitMaster 165 TransitMaster 185 Maximum 6° Maximum 6° 196.85 ft (60m) 0.4m/s with inverter, 0.5m/s, 0.65m/s, 0.75m/s 328.08 ft (100m)** 0.4m/s with inverter, 0.5m/s, 0.65m/s , 0.75m/s 3' 3 3/8" (1000 mm) 3' 3 3/8" (1000 mm) 3' 11 1/4" (1200 mm) 3' 11 1/4" (1200 mm) 4' 7 1/8"(1400 mm) 4' 7 1/8"(1400 mm) Glass, solid inclined Glass, solid inclined 3' 3 3/8" (1000 mm) 3' 3 3/8" (1000 mm) C-type C- and V-type Inside roller chains Outside roller chains Operational environment Indoor, semi-outdoor Indoor, semi-outdoor Duty cycle 20 – 24 hours/day*** 20 – 24 hours/day*** ** Longer units are available via order engineering. Please contact KONE for more information. *** 24 hours duty cycle is possible with additional maintenance. KONE ECOMOD ® New escalators the quick and easy way It’s wise to modernize KONE offers a complete escalator modernization solution without the expense and disruption of removing the existing truss. KONE EcoMod delivers brand new escalator technology without the need to demolish floors, roofs and building façades, and there’s always an escalator available for passengers. KONE EcoMod is designed to be compatible with both KONE escalators and equipment from other manufacturers. During modernization we can maintain continuous people flow through the ability to keep one escalator running while we work on the other. n n Lengthy process with extensive construction New technology = better escalators n Substantial general contractor costs for work by others KONE EcoMod installation advantages n n Quicker, cleaner and less costly than a new installation Modifying the existing truss means no major structural modifications Reuse of existing cladding and decking for significant cost-savings n One or more escalators always available to passengers n Increased building value and simplified budgeting process Traditional installation disadvantages n Additional time for removal and prep of structural and related elements n Improved equipment dependability and performance n Enhanced safety and reliability n Energy-efficient technology to help lower operating costs Complete escalator shutdown during construction n n Major disruption to people flow n Improved user experience with smoother rides n Potential to increase building value Note (1) For additional information please contact your KONE Sales Professional. Efficient installation 1 A KONE EcoMod complete escalator modernization begins with the removal of all existing mechanical and electrical components. The existing truss is then modified to accept KONE EcoMod modules, allowing quick installation of the latest technology without major disruption. 2 3 1 Upper module 2 Incline modules 3 Lower module *All drawings are for illustration purposes only. KONE provides innovative and eco-efficient solutions for elevators, escalators and the systems that integrate them with today’s intelligent buildings. We support our customers every step of the way: from design, manufacturing and installation to maintenance and modernization. KONE is a global leader in helping our customers manage the smooth flow of people and goods throughout their buildings. Our commitment to customers is present in all KONE solutions. This makes us a reliable partner throughout the life cycle of the building. We challenge the conventional wisdom of the industry. We are fast, flexible, and we have a well-deserved reputation as a technology leader, with such innovations as KONE MonoSpace® DX, KONE EcoMod® and KONE UltraRope®. KONE employs over 60,000 dedicated experts to serve you globally and locally. KONE kone.us Copyright © 2022 KONE Inc. All rights reserved. All examples and images are for illustration purposes only. Actual data, information, and results may vary. *Separate agreement and charges apply. KONE maintenance agreement required. KONE not responsible for third-party wireless service interruptions. SF2861 – Rev 0322 Printed in the U.S.