BEFORE DIGGING OR BACKFILLING - PAGE 505-283-4477(x-4GPS) FOR SNL S OFFICIAL USE ONLY X DEMO KEYED NOTES 1. REMOVAL OF EXISTING LANDSCAPE AREA. REMOVAL P.O. PROJECT NO. REV DATE DWN CKD DESCRIPTION APP US DEPARTMENT OF ENERGY ALBUQUERQUE, NEW MEXICO NNSA/SANDIA SITE OFFICE SANDIA NATIONAL LABORATORIES DEMO PLAN P.O. 218935 PROJECT NO. TA-I INFRASTRUCTURE 810 BACKUP GENERATOR 20' 10' 0 20' HORIZ SCALE 1"=20' OFFICIAL USE ONLY OLD FILENAME: CD1001.DWG FILENAME: CD1001.DWG DRAWN BY BF CHECKED BY GB SNL ENGR DISCP:C SUB-DISCP: D UTILS DATE SIZE www.bhinc.com 800.877.5332 D+ DRAWING NO. CD1001 03/19 SEQ. "Property of Sandia National Laboratories Facilities Management and Operation Center (FMOC). No alteration allowed without the expressed authorization of FMOC." 1 BEFORE DIGGING OR BACKFILLING - PAGE 505-283-4477(x-4GPS) FOR SNL S OFFICIAL USE ONLY X SITE PLAN KEYED NOTES 1. INSTALL CONCRETE PAD. BUILDING 810 FRONT ENGINE GENERATOR 1 T ALL WORK IS NEW P.O. PROJECT NO. REV DATE DWN CKD DESCRIPTION APP US DEPARTMENT OF ENERGY ALBUQUERQUE, NEW MEXICO NNSA/SANDIA SITE OFFICE SANDIA NATIONAL LABORATORIES SITE PLAN P.O. 218935 PROJECT NO. TA-I INFRASTRUCTURE 810 BACKUP GENERATOR 20' 10' 0 20' HORIZ SCALE 1"=20' OFFICIAL USE ONLY OLD FILENAME: CP1001.DWG FILENAME: CP1001.DWG DRAWN BY BF CHECKED BY GB SNL ENGR DISCP:C SUB-DISCP: P UTILS DATE SIZE www.bhinc.com 800.877.5332 D+ DRAWING NO. CP1001 03/19 SEQ. "Property of Sandia National Laboratories Facilities Management and Operation Center (FMOC). No alteration allowed without the expressed authorization of FMOC." PANEL NOTE: SURVEY OF SITE HAS NOT BEEN COMPLETED AT THIS TIME. GRADES WILL BE PROVIDED AT THE NEXT SUBMITTAL. BUILDING 810 BEFORE DIGGING OR BACKFILLING - PAGE 505-283-4477(x-4GPS) FOR SNL S OFFICIAL USE ONLY FRONT ENGINE GENERATOR T ALL WORK IS NEW P.O. PROJECT NO. REV DATE DWN CKD DESCRIPTION APP US DEPARTMENT OF ENERGY ALBUQUERQUE, NEW MEXICO NNSA/SANDIA SITE OFFICE SANDIA NATIONAL LABORATORIES GRADING PLAN P.O. 218935 PROJECT NO. TA-I INFRASTRUCTURE 810 BACKUP GENERATOR 20' 10' 0 20' HORIZ SCALE 1"=20' OFFICIAL USE ONLY OLD FILENAME: GP1001.DWG FILENAME: GP1001.DWG DRAWN BY BF CHECKED BY GB SNL ENGR DISCP:G SUB-DISCP: P UTILS DATE SIZE www.bhinc.com 800.877.5332 D+ DRAWING NO. GP1001 03/19 SEQ. "Property of Sandia National Laboratories Facilities Management and Operation Center (FMOC). No alteration allowed without the expressed authorization of FMOC." PANEL CLR. 3/4" CHAMFER, TYP. 4" 2" SEE PLAN 10" 4" #4 HOOKED REBAR @ 36" MAX. EA. WAY. DRILL AND EPOXY W/ HILTI HIT-RE 500 SD OR APPROVED EQUAL. EMB. EXISTING FOUNDATION SLAB 2" #4 @ 12" O.C.E.W. NOTE:HOUSEKEEPING PAD SHALL EXTEND A MINIMUM OF 6" BEYOND EDGE OF MECHANICAL EQUIPEMENT IN ALL DIRECTIONS 1 HOUSEKEEPING PAD DETAIL SCALE: NOT TO SCALE RMF RND GENERATOR BACKUP P.O. REV DATE DESCRIPTION DWN CKD APP PROJECT NO. U.S. DEPARTMENT OF ENERGY NNSA/SANDIA SITE OFFICE ALBUQUERQUE, NEW MEXICO SANDIA NATIONAL LABORATORIES P.O. FOUNDATION DETAILS PROJECT NO. Center for National Security Bohannan CHECKED BY Arms Control Huston of DRAWN BY SNL ENGR Courtyard I 7500 Jefferson St. NE Albuquerque, NM 87109 (505) 823-1000 OLD FILENAME: FILENAME: DISCP: S SUB-DISCP: 810 SIZE SB5002810.DGN SB5002810.DGN B A Joint Venture D+ DATE DRAWING NO SB5002810 07/09/2020 SEQ. FMOC. " of expressed authorization 07/20 al l ow ed w ithout the A 218935 al teration ALL WORK ON THIS DRAWING IS INCLUDED IN PROJECT SCOPE OF WORK No A Sandia NationalLaboratories Facil ities Managem ent and Operation Center ( FMOC) . SB5002 " Property MH4001 OFFICIAL USE ONLY MECHANICAL SYMBOLS AND ABBREVIATIONS STANDARD SYMBOLS ABBREVIATIONS DESCRIPTION HVAC PIPING SYMBOL DESCRIPTION NH AMMONIA 3 SYMBOL DESCRIPTION SYMBOL DESCRIPTION SYMBOL PROCESS OIL SUPPLY FLUORINE RO REVERSE OSMOSIS WATER BALL VALVE 30 ELBOW RETURN AIR (R. A.) SCW SOFTENED COLD WATER GATE VALVE 90 ELBOW OUTSIDE AIR (O. A.) GLOBE VALVE TEE (SHOW SIZES WHEN REDUCING TEE) PARALLEL BLADE DAMPER PLUG COCK CAP OPPOSED BLADE DAMPER SWING CHECK VALVE RUPTURE DISK SPRING CHECK VALVE SEALED AIR CHAMBER SHOCK ABSORBER HOSE BIBB FLOOR DRAIN CHILLED WATER SUPPLY F CWR CHILLED WATER RETURN PAR PROCESS ARGON HWS HEATING WATER SUPPLY PH 3 PHOSPHINE HWR HEATING WATER RETURN PN 2 PROCESS NITROGEN TWS TOWER WATER SUPPLY R12 DICHLORODIFLUOROMETHANE D.A. DIRECT ACTING TWR TOWER WATER RETURN R14 TETRAFLUOROMETHANE R.A. REVERSE ACTING LPS LOW PRESSURE STEAM Si2H6 DISILANE do. DITTO MPS MEDIUM PRESSURE STEAM SiH SILANE HPS HIGH PRESSURE STEAM C CONDENSATE, GRAVITY PC DESCRIPTION POS (TOXIC) CWS 4 SYMBOL DESCRIPTION VALVES (HIGHLY TOXIC) GENERAL NOTATION (PYROPHORIC/TOXIC) (PYROPHORIC/TOXIC) GASES S SUPPLY AIR (S. A.) 45 ELBOW FOR REFERENCE ONLY (SYMBOLS AND ABBREVIATIONS DISCONTINUED AND/OR REVISED) AIR PROPORTIONING VANE APV E.W.C. ELECTRIC WATER COOLER NEEDLE VALVE FLOOR SINK HD HAND DAMPER G.F.E. GOVERNMENT FURNISHED EQUIPMENT BUTTERFLY VALVE EXPANSION JOINT BD BALANCING DAMPER N.C. NORMALLY CLOSED MOTOR OPERATED GLOBE VALVE LINE STRAINER DCW DEMINERALIZED COLD WATER N.O. NORMALLY OPENED MOTOR OPERATED GATE VALVE CLEAN-OUT TO GRADE CMS CENTRAL MONITORING SYSTEM SOLENOID OPERATED VALVE CONDENSATE, PUMPED AR ARGON FOS FUEL OIL SUPPLY BA BREATHING AIR O.A.E. OR APPROVED EQUAL FOR FUEL OIL RETURN CA COMPRESSED AIR P.C.C. PLANT CONTROL CENTER A B COTG ~ SYMBOL PCW OPEN SIGHT DRAIN, AIR GAP SOLENOID OPERATED 3-WAY VALVE WCO SANDIA FURNISHED EQUIPMENT SELF-CONTAINED TEMP. CONTROL VALVE FCO SHEET METAL VENT THRU ROOF PROCESS COLD WATER WALL CLEANOUT (WCO) RD REFRIGERANT DISCHARGE FLOOR CLEANOUT (FCO) RL REFRIGERANT LIQUID EXTERNAL, PRESSURE REDUCING VALVE DIRECTION AND FLOW RS REFRIGERANT SUCTION INTERNAL, PRESSURE REDUCING VALVE PRESSURE GAUGE C FUEL OIL GAGE LINE CDA FOV FUEL OIL TANK VENT CH4 C 2H2 CLEAN DRY AIR S.F.E. METHANE S.M. V.T.R. ACETYLENE A CO2 PLUMBING CARBON DIOXIDE W/ AB WITH COLD WATER G RWL 3-WAY PNUEMATIC CONTROL VALVE NATURAL GAS W/O AB WITHOUT 3-WAY MOTORIZED CONTROL VALVE RAINWATER LEADER FC FLOW CONTROL VALVE AIR VENT (SPECIFY MANUAL, AUTOMATIC OR VACUUM) FT F & T TRAP DM DAMPER MOTOR T THERMOSTATIC TRAP EP ELECTRIC-PNEUMATIC RELAY B BUCKET TRAP CONTROLS B A CW ~ FOG A.V. B DIAPHRAGM VALVE AIR PROPORTIONING VANE BACKFLOW PREVENTER FS THERMODYNAMIC TRAP TD FLOW SWITCH 0-100 PSI PRESSURE GAUGE (WITH PRESSURE RANGE AND BUTTERFLY VALVE GAUGE COCK) FT LIQUID CARBON DIOXIDE F & T TRAP VOLUME DAMPER V.D. PE PNEUMATIC-ELECTRIC RELAY ST STEAM AND CONDENSATE PRESSURE SWITCH L LOUVER OPENING ORIFICE FLOW METER RELIEF T V VENT LH2 LIQUID HYDROGEN S D GRAVITY DRAIN LN2 LIQUID NITROGEN S.D. SMOKE DAMPER PD PRESSURE DRAIN LO2 LIQUID OXYGEN F.D. FIRE DAMPER AD ACID WASTE, GRAVITY LPG LIQUID PETROLEUM GAS AV ACID VENT N2 NITROGEN PS THERMOSTATIC TRAP SPLITTER DAMPER VAC. B BUCKET TRAP VACUUM RELIEF TD THERMODYNAMIC TRAP R FITTINGS SCREWED JOINT MISCELLANEOUS RELAY TS TEMPERATURE SWITCH T THERMOSTAT 40-140 F PAD ACID DRAIN, PUMPED O 2 FLANGED JOINT CENTRIFUGAL PUMP OXYGEN THERMOMETER (WITH TEMPERATURE RANGE) NOTE: IF NECESSARY TO ADD SYMBOLS AND ABBREVIATIONS THAT HAVE NOT RWL RAIN WATER LEADER PV WELDED JOINT NUMBER PROCESS VACUUM BEEN SHOWN ON THIS LEGEND THEY SHALL BE ADOPTED FROM ASME/ANSI STANDARDS AND/OR APPROVED BY SNL AND REFLECTED AS AN ADDITION. VENTURI FLOW METER 1 DETAIL BUBBLE ORWL SS OVERFLOW RAIN WATER LEADER VAC VACUUM UNION 1 STORM SEWER SPECIALTY GASES PROCESS LIQUIDS (CLASSIFICATION) 1 EQUIPMENT LIST DESIGNATION CONCENTRIC REDUCER END POINT OF REMOVAL ECCENTRIC REDUCER KEYED CONSTRUCTION NOTE E ELECTRIC HVAC C 6-1 5-01 UDS MODS B 1/00 REVISED 4-92 REVISED EG FL YMA DW ACOUSTICAL LINING (A.L.) AIR SUPPLY DIFFUSER ELBOW, TURNED DOWN PES PHS P.O. REV DATE DESCRIPTION DWN CKD APP PROJECT NO. ARSINE (HIGHLY TOXIC) DI DEIONIZED WATER MH MAN HOLE U.S. DEPARTMENT OF ENERGY RETURN AIR OR EXHAUST GRILLE ELBOW, TURNED UP NNSA/SANDIA SITE OFFICE Cl2 DMC CHLORINE DIMETHYLCADMIUM (CORROSIVE) (METAL ORGANIC) HF PCWR HYDROFLUORIC ACID PROCESS COLD WATER RETURN POINT OF CONNECTION FROM NEW TO EXISTING CONSTRUCTION TEE, TURNED UP TEE, TURNED DOWN LETTER DL DOOR LOUVER ALBUQUERQUE, NEW MEXICO SANDIA NATIONAL LABORATORIES P.O. Symbols And Abbreviations FINNED PIPE RADIATION PROJECT NO. SECTION BUBBLE DMT DIMETHYLTELLURIUM H2 Se HYDROGEN SELENIDE HCL HYDROGEN CHLORIDE (METAL ORGANIC) PCWS PROCESS COLD WATER SUPPLY VALVE IN RISER PROCESS OIL RETURN ARROW HEAD USED FOR LEADERING VALVE ON ELBOW UP BREAK VALVE ON ELBOW DOWN EXHAUST AIR (E. A.) Standards DRAWN BY of AsH3 CHECKED BY (TOXIC) POR SNL ENGR DISCP: (CORROSIVE) OLD FILENAME: OFFICIAL USE ONLY FILENAME: M SUB-DISCP: STD SIZE 150500M.01 M-0001STD.dgn - A Joint Venture D+ DATE DRAWING NO M-0001STD 06/30/2001 SEQ. FMOC. " LCO2 SANITARY SEWER of S expressed authorization A.P.V. LIQUID ARGON ACCESS DOOR al l ow ed w ithout the LAR A.D. HELIUM al teration NON POTABLE WATER RELIEF VALVE HVAC DUCTWORK No NPW HE WATER HOUSE CLEANING VACUUM Center ( FMOC) . W HCV HOT WATER CIRCULATING ANGLE VALVE HYDROGEN Sandia NationalLaboratories Facil ities Managem ent and Operation HWC H2 HOT WATER " Property HW EQUIPMENT SCHEDULE EQUIPMENT SHALL BE SIZED FOR 5,500 FT. ELEVATION DESCRIPTION SYMBOL 340 DESCRIPTION SYMBOL BLOWER COIL UNIT: 342 GENERAL HORIZONTAL FAN COIL UNIT TESTED IN ACCORDANCE WITH ARI 430 AND ARI 260. THE UNIT TO COMPLY WITH NFPA 90A AND IS UL LISTED IN THE U. S. FAN COIL TO CONSIST OF A HYDRONIC COIL, DRAIN PAN, AND CENTRIFUGAL FAN WITH MOTOR AND DRIVE MOUNTED IN A COMMON CABINET. DRIVE LOCATION AND COIL CONNECTIONS ARE INDEPENDENT FOR THE SAME OR OPPOSITE SIDE LOCATION. AIR HANDLERS ARE PROVIDED WITH KNOCKOUTS IN ALL FOUR CORNERS FOR INSTALLING THE UNIT SUSPENDED FROM THE CEILING WITH THREADED RODS. SYMBOL DESCRIPTION DESCRIPTION SYMBOL ELECTRIC HOT WATER BOILER CONTINUED: ELECTRICAL ENTRANCE SHALL BE MADE THROUGH THE TOP OF THE ELECTRICAL CONTROL PANEL. ALL FIELD ELECTRICAL WIRING CONNECTIONS TO THE BOILER SHALL BE MADE TO A MAIN TERMINAL BLOCKS. THERE SHALL BE 3 MAIN TERMINAL BLOCK(S) WITH 4 WIRES PER PHASE PER ENTRANCE. ALL INTERNAL WIRING SHALL BE MADE TO SOLDERLESS TERMINAL LUG WIRING CONNECTIONS. WIRING TO BE COLOR CODED OR NUMBERED FOR EASE OF SERVICING. ALL POWER CIRCUITS TO HEATING ELEMENTS SHALL BE FUSED WITH CARTRIDGE. ALL POWER CIRCTUITS TO HE ATING ELEMENTS SHALL BE FUSED WITH CARTRIDGE TYPE FUSES HAVING A MINIMUM 100,000 AMP INTERRUPTING CAPACITY. OPERATION OF THE HEATING ELEMENTS SHALL BE SWITCHED BY THREE POLE MAGNETIC CONTRACTORS OPERATED BY A 120 VOLT CONTROL CIRCUIT. THE CONTROL CIRCUIT SHALL USE A BUILT IN TRANSFORMER TO REDUCE LINE VOLTAGE TO 120 VOLTS FOR OPERATION OF THE CONTROL CIRCUIT COMPONENTS. THE CONTROL CIRCUIT SHALL BE FUSED ON THE PRIMARY SIDE AS WELL AS FUSED AND GROUNDED ON THE SECONDARY SIDE. CASING CASINGS IS TO BE CONSTRUCTED OF 18-GAUGE GALVANIZED STEEL, INSULATED WITH ONE-INCH, 1-1/2 LB DENSITY FIBERGLASS FIRE RESISTANT AND ODORLESS GLASS FIBER MATERIAL TO PROVIDE THERMAL AND ACOUSTICAL INSULATION. FAN HOUSING SIDES ARE TO BE DIRECTLY ATTACHED TO THE AIR HANDLER TOP AND BOTTOM PANELS. COIL ACCESS PANELS SHALL BE LOCATED ON BOTH SIDES OF THE AIR HANDLER. ADDITIONAL ACCESS PANELS SHALL BE PROVIDED ON BOTH SIDES OF THE FAN COIL UNIT FOR MOTOR AND DRIVE ACCESS. TEMPERATURE CONTROL SHALL BE WITH A PROPORTIONAL SOLID STATE STEP CONTROL TO BALANCE HEAT INPUT DEMAND. THE STEP CONTROL SHALL PROVIDE 8 STEPS OF LOAD. THE STEP CONTROL SHALL HAVE AN ADJUSTABLE WATER TEMPERATURE SET POINT AND THROTTLING RANGE. THE HOT WATER BOILER SHALL BE PROVIDED WITH AN ADJUSTABLE AUTO RESET HIGH LIMIT CONTROL AND AN ADDITIONALMANUAL RESET HIGH LIMIT CONTROL. COOLING COIL COOLING COIL SHALL BE CONSTRUCTED WITH SEAMLESS COPPER TUBING IN TWO, FOUR, OR SIX-ROW ARRANGEMENT AND FURNISHED WITH MECHANICALLY BONDED ALUMINUM FINS AT 12FPI. COILS SHALL BE FACTORY TESTED WITH 450 PSI AIR UNDER WATER. THE IMMERSION HEATING ELEMENTS SHALL BE LOW WATT DENSITY WITH AN INCOLY OUTER SHEATH MATERIAL FOR LONGER LIFE. EACH HEATING ELEMENT SHALL BE SIZED AT A MAXIMUM OF 75 WATTS PER SQUARE INCH OF HEATING SURFACE. THE HEATING ELEMENTS SHALL BE A THREE BEAM DESIGN AND MOUNT IN INDIVIDUAL TANK FLANGES. EACH HEATING ELEMENT SHALL NOT EXCEED 18 KW OF INPUT PER FLANGED CONNECTION. FAN THE FAN SHALL BE FORWARD CURVED, CENTRIFUGAL BLOWER TYPE EQUIPPED WITH HEAVY-DUTY ADJUSTABLE SPEED V-BELT DRIVE. THE FAN SHAFT IS SUPPORTED BY HEAVY-DUTY, PERMANENTLY SEALED BALL BEARINGS. FAN SHALL BE DYNAMICALLY BALANCED. THE ELECTRIC HOT WATER BOILER SHALL BE A COMPLETE FACTORY PACKAGE WITH THE FOLLOWING TRIM FURNISHED AS STANDARD: ON-OFF PILOT SWITCH WITH PILOT LIGHT TO MANUALLY OPERATE THE 120 VOLT CONTROL CIRCUIT, STATUS PILOT LIGHT FOR EACH STAGE OF OPERATION, PREHEAT SWITCH WITH PILOT LIGHT ON UNITS ABOVE 240KW PROBE TYPE ELECTRONIC LOW WATER CUT OFF, PRESSURE GAUGE WITH COCK, TEMPERATURE INDICATOR, DRAIN VALVE AND AN ASME RATED PRESSURE RELIEF VALVE(S). THE BOILER SHALL BE FACTORY ASSEMBLED, WIRED AND TESTED. THE ENTIRE HOT WATER BOILER SHALL BE U.L. LISTED AND PROVIDE A 3 YEAR LIMITED WARANTY ON THE VESSEL AND A 1 YEAR LIMITED WARANTY ON PARTS. LOCHINVAR MODEL: BWX24-480F DRAIN PAN STAINLESS STEEL DRAIN PAN TO BE DOUBLE-SLOPED TO ALLOW CONDENSATE DRAINAGE. THE DRAINPAN CONSTRUCTION SHALL BE STAINLESS STEEL WITH ¾” NPT CONNECTION. THE MAIN DRAIN CONNECTION TO BE LOCATED THE LOWEST POINT OF THE DRAIN PAN. FILTERS FURNISHED WITH TWO-INCH PLEATED MERV 8 (30% EFFICIENT) FILTERS. FLAT FILTER RACK TO BE SIZED FOR LESS THAT 500 FEET PER MINUTE AT NOMINAL AIRFLOW. SYM MOTORS FURNISH OPEN DRIP-PROOF MOTOR WITH PERMANENTLY SEALED BALL BEARINGS, INTERNAL CURRENT AND THERMAL OVERLOAD PROTECTION, WITH A MINIMUM 1.15 SERVICE FACTOR AND 56 FRAME RESILIENT BASES. MOTORS SHALL BE FACTORY INSTALLED AND WIRED TO THE JUNCTION BOX. 342 CONTROLS UNIT SHALL BE FURNISHED WITH COMPLETE FACTORY CONTROLS, INCLUDING: 2-WAY CONTROL VALVE AND PROGRAMMABLE THERMOSTAT. UNIT SHALL BE FURNISHED WITH CONTACTS CAPABLE OF INDICATING A GENERAL ALARM SIGNAL (FAN FAILURE, LOW CHILLED WATER FLOW, OR HIGH TEMPERATURE), TO BE CONNECTED TO THE A/V CONSOLE BY OTHERS. EWT (F) LWT (F) FLOW RATE (GMP) 145 180 95 DESIGN WATER PRESSURE RATING (PSIG) 160 CAPACITY (MBH) 1638 ELEC. (KW)(V) (FLA) 480 480V/3PH/60HZ 578 SAFETY RELIEF VALVE SETTING (PSIG) 100 FLOAT SWITCH FURNISH CONDENSATE OVERFLOW DRAIN PAN FLOAT SWITCH. THE SWITCH SHALL DISABLE UNIT IN THE EVENT OF CONDENSATE OVERFLOW. 343 INLINE CIRCULATION PUMP: MFR.: TRANE BCHD 3-PIECE INLINE PERMANENTLY LUBRICATED PUMPS FOR HOT WATER HEATING SYSTMS. PUMPS SHALL BE OF A HORIZONTAL, PERMANENTLY LUBRICATED TYPE, SPECIFICALLY DESIGNED FOR QUIET OPERATION. SUITABLE FOR 225° F OPERATION AT 175 PSIG WORKING PRESSURE. THE PUMP SHALL BE SINGLE STAGE, VERTICAL SPLIT CASE DESIGN, IN CAST IRON BRONZE FITTED (OR ALL BRONZE) CONSTRUCTION. THE PUMP INTERNALS SHALL BE CAPABLE OG BEING SERVICED WITHOUT DISTURBING PIPING CONNECTIONS. SUPPLY FAN CAPACITY: FANCFM SYM QTY.FAN EXT. TOT. FAN SP, IN. SP,IN. RPM 340 600 0.5 SYM OPERATING WEIGHT,LBS. 4 55 3.5 11.95 17.46 FACE AREA, SQ.FT. 2.0 CEILING GRILLE: ALUMINUM CORE OF 1/2" X 1/2" X 1/2" SQUARES IN STEEL FRAME FOR USE IN EXPOSED TEE BAR CEILING. SIZED AS SHOWN ON THE DRAWINGS. MFR.: PRICE 80 ELECTRIC HOT WATER BOILER : SANDIA FURNISHED EQUIPMENT (SFE) THE HOT WATER BOILER SHALL BE AVAILABLE WITH ELECTRIC INPUTS FROM 440KW UP TO 3600KW. THE BOILER VESSEL SHALL BE CONSTRUCTED IN ACCORDANCE WITH SECTION IV OF THE ASME BOILER AND PRESSURE VESSEL CODE REQUIREMENTS IV, “H” STAMPED AND REGISTERED WITH THE NATIONAL BOARD OF BOILER AND PRESSURE VESSELS. THE VESSEL SHALL BE EQUIPPED WITH (THREADED) (FLANGED) 4" INLET AND OUTLET CONNECTIONS, SAFETY VALVE AND DRAIN NOZZLE CONNECTIONS AS REQUIRED. ALL PLUMBING CONNECTIONS SHALL BE OF EXTRA HEAVY PIPE. THE VESSEL SHALL BE ENCLOSED IN A RECTANGULAR 16-GAUGE JACKET AND BE COMPLETELY INSULATED WITH A 3" BLANKET OF FIBERGLASS INSULATION. THE JACKET ASSEMBLY SHALL INCLUDE A FULL SIZED ELECTRICAL CONTROL PANEL SEPARATED BY AN AIR GAP. A 2" MINIMUM GAP SHALL BE PROVIDED BETWEEN THE VESSEL AND ELECTRICAL PANEL TO KEEP COMPONENTS AND CONTROLS AT A REDUCED AMBIENT TEMPERATURE FOR EXTENDED SERVICE LIFE. THE ELECTRICAL CONTROL PANEL SHALL HAVE TWO FULL-LENGTH HINGED DOORS WITH KEY LOCKS FOR ACCESS TO HEATING ELEMENTS AND CONTROLS. THE ASSEMBLED ELECTRICAL BOILER JACKET AND CONTROL PANEL SHALL HAVE AN ACRYLIC ENAMEL FINISH. THE ASSEMBLED BOILER SHALL HAVE A COMMON STRUCTURAL AND VESSEL JACKET. THE STEEL BASE ALLOWS EASE OF INSTALLATION AND PROVIDES PROPER SUPPORT AS A PERMANENT BASE. BEARING ASSEMBLY SHAFT SHALL CONNECT TO EITHER A CAST BRONZE IMPELLER. IMPELLER SHALL BE HYDRAULICALLY AND DYNAMICALLY BALANCED, KEYED TO THE SHAFT AND SECURED BY A LOCKING CAPSCREW OR NUT. A FLEXIBLE TYPE COUPLING SHALL BE EMPLOYED BETWEEN THE PUMP AND MOTOR. PUMP SHOULD BE DESIGNED TO ALLOW FOR TRUE BACK PULL-OUT ACCESS TO THE PUMP'S WORKING COMPONENTS FOR EASE OF MAINTENANCE. PUMP VOLUTE SHALL BE OF CAST IRON DESIGN FOR HEATING SYSTEMS OR CAST BRONZE FOR DOMESTIC WATER SYSTEMS. THE CONNECTION STYLE ON CAST IRON AND BRONZE PUMPS SHALL BE FLANGED. VOLUTE SHALL INCLUDE GAUGE PORTS AT NOZZLES, AND VENT AND DRAIN PORTS. TO ENSURE ALIGNMENT THE MOTOR SHALL BE MOUNTED TO THE BEARING ASSEMBLY VIA A BOLTED MOTOR BRACKET ASSEMBLY, AND A RUBBER MOTOR MOUNT SHALL BE USED TO ASSIST IN ALIGNING THE MOTOR SHAFT WITH THE PUMP SHAFT. MOTORS SHALL MEET SCHEDULED HORSEPOWER, SPEED, VOLTAGE, AND ENCLOSURE DESIGN. MOTORS THROUGH 1HP SHALL BE RESILIENT MOUNTED, MOTORS OVER 1.5HP SHALL BE RIGID MOUNTED. MOTORS SHALL HAVE PERMANENTLY LUBRICATED BALL BEARIMGS AND MUST BE COMPLETELY MAINTENANCE FREE. MOTORS SHALL BE NON-OVERLOADING AT ANY POINT ON THE PUMP CURVE AND SHALL MEET NEMA SPECIFICATIONS. PUMP SHALL BE OF A MAINTAINABLE DESIGN AND FOR EASE OF MAINTENANCE SHOULD USE MACHINE FIT PARTS AND NOT PRESS FIT COMPONENTS. PUMP MANUFACTURER SHALL BE ISO-9001 CERTIFIED AND BE OF U.S. MANUFACTURER. EACH PUMP SHALL BE FACTORY TESTED AND NAME-PLATED BEFORE SHIPMENTAND SHALL BE PROVIDED WITH A 3 YEAR WARRANTY FROM DATE OF INSTALLATION. B&G MODEL 3X3X5.25 SERIES E-60 203812 A 10/17 C117 RENOVATION - PKG 5 - AS-BUILT CAW AJB 218935 B 07/20 810 GENERATOR KMQ RTC P.O. REV DATE DESCRIPTION DWN CKD APP PROJECT NO. U.S. DEPARTMENT OF ENERGY SYM FLOWRATE HEAD (GMP) (FTHD) SHUT OFF HEAD (FTHD) NNSA/SANDIA SITE OFFICE BHP ALBUQUERQUE, NEW MEXICO SANDIA NATIONAL LABORATORIES 343 95 15 20.6 0.6 P.O. MECHANCIAL EQUIPMENT SCHEDULE EFF 60% MOTOR (HP) SPEED (RPM) ELEC. .75 1800 480/3/60 Center for National Security Arms Control ODP PROJECT NO. 203812 DRAWN BY C.WATSON CHECKED BY A.BECK SNL ENGR DISCP: B OLD FILENAME: FILENAME: SK-M6-01.DGN SK-M6-01.DGN M SUB-DISCP: - 810 SIZE D+ DATE DRAWING NO. M-6010810.DGN 7/31/2017 SEQ. FMOC. " 4.01 ROWS 45 T.H. MBH of 1.23 WATER P.D.,FT 55.0 S.H. MBH expressed authorization AIR P.D. IN.,W.G. 67 GPM al l ow ed w ithout the 80 LWT DEG.F. al teration 54.18 600 EWT DEG.F. PUMP SHALL BE EQUIPPED WITH AN INTERNALLY-FLUSHED MECHANICAL SEAL ASSEMBLY. SEAL ASSEMBLY SHALL BE THE UNITIZED TYPE WITH STAINLESS STEEL SPRING, AND BE OF A CARBON SILiCON-CARBIDE DESIGN WITH THE CARBON FACE ROTATING AGAINST A STATIONARY SILICON-CARBIDE FACE. No THE PUMPS SHALL HAVE A SOLID SAE 1144 STEEL SHAFT SUPPORTED BY TWO SEALED BALL BEARINGS. A NON-FERROUS SHAFT SLEEVE SHALL BE EMPLOYED TO COMPLETELY COVER THE WETTED AREA AROUND THE SEAL. SOUND POWER LEVEL (dB) DISCHARGE 1 2 3 4 5 6 7 8 87 89 79 74 72 69 66 61 340 Center ( FMOC) . PROJECTION ROOM Sandia NationalLaboratories Facil ities Managem ent and Operation 342 115/1/60 THE PUMPS SHALL BE COMPOSED OF THREE SEPARABLE COMPoNENTS A MOTOR, BEARING ASSEMBLY, AND PUMP END (WET END). THE MOTOR SHAFT SHALL BE CONNECTED TO THE PUMP SHAFT VIA A REPLACABLE FLEXIBLE COUPLER. WB LVG. 340 0.5 SERVICE CHILLED WATER COOLING COIL: CLG DB WB DB SYM CFM IN IN LVG. SYM 341 0.3 POWER V/PH of SYM 340 100 1353 FAN HP " Property 340 1.3 FAN BHP GENERAL NOTES FOR MECHANICAL EQUIPMENT SCHEDULE SEE SHEET M-6010810 KEYED NOTES 1 ROUTE BOILER FLUES THROUGH ROOF. OFFSET FLUES TO MAINTAIN CLEARANCE TO THE EVAPORATIVE COOLER. 2 ROUTE BOILER COMBUSTION AIR THROUGH ROOF. 3 INSTALL NEW UNIT HEATER AT APPROXIMATE LOCATION SHOWN. 5 FIRE T FIRE PANEL RISER MH4001810A HWS HWR M-HSM5001 4 ROUTE DISCHARGE DUCTWORK FROM EVAPORATIVE COOLER ON ROOF TO CUB. INSTALL 3-WAY PATTERN DIFFUSER ON DISCHARGE OF 5 NEW 12"x24" DRAINABLE BLADE LOUVER EQUAL TO RUSKIN MODEL ELF6375DX. 6 LEAVE AREA CLEAR FOR FUTURE EQUIPMENT. 7 VENT LINE SHOWN ON THIS DRAWING FOR CLARITY. 8 INSTALL NEW ELECTRIC BOILER ON NEW HOUSEKEEPING PAD. SEE STRUCTURAL DETAIL . 8" 6" 8" BYPASS 6" 8" BYPASS 242 221 6 1 213 MH4001 SB5002 222 9 5 NEW CIRCULATOR PUMP. 6 10 248 MAINTAIN CLEARANCE AROUND ELECTRIC BOILER. 214 243 8" 8" 59 2 64" 2 1 8" CA (TYP 3x)(TYP 3) 2" HWR 2" VENT HEADER HWS 6" HWS/R FUTURE 7 A 8" FLUE (TYP 3) 244 2" VENT UP HWS 223 HWR 6 215 HWR 229 6" 6 6 2" VENT UP 4 8" 9 343 HWS 7 2" VENT HEADER HWR T 230 8" 6 A 59 1 64" 342 59 1 64" 810A CUB HVAC PLAN A 218935 SCALE: 1/2" = 1'-0" 07/20 KMQ RTC 810 GENERATOR P.O. REV DATE DESCRIPTION DWN CKD APP PROJECT NO. U.S. DEPARTMENT OF ENERGY NNSA/SANDIA SITE OFFICE ALBUQUERQUE, NEW MEXICO SANDIA NATIONAL LABORATORIES P.O. ENLARGED HVAC FLOOR PLAN PROJECT NO. CUB for 810 of DRAWN BY CHECKED BY SNL ENGR DISCP: OLD FILENAME: 0 1' 2' 4' 6' FILENAME: M SUB-DISCP: 810A SIZE MH4001810A.DGN MH4001810A.DGN H A Joint Venture DATE DRAWING NO D+ MH4001810A.DGN 02/13/2008 SEQ. FMOC. " 6" HWS/R TO BLDG 810 of PANEL IBLI expressed authorization IBHI al l ow ed w ithout the 245 al teration 6 " Property 10 HWS 3 No 8 Sandia NationalLaboratories Facil ities Managem ent and Operation Center ( FMOC) . 6 HWR 1. GENERAL NOTES MODULE WIRING DETAILS 1. ALL CABLE TO BE PULLED CONTINUOUS FROM PROGRAMABLE EXPANDABLE CONTROLLER (PXC) TO FINAL TERMINATION POINT WITH NO SPLICES ALLOWED. WIRING GUTTER SWITCH WITH LOCKABLE ANALOG INPUT RESISTIVE SENSORS WIRING EXAMPLE (TYPE LAI-1) 2. ALL DO WIRE SHALL BE #14 TYPE THHN OR TFFN BLACK/PURPLE. PURPLE CONDUCTOR TO DESIGNATE NEGATIVE (COMMON). ALL DI WIRE SHALL BE #20 TWISTED STRANDED PAIR W/BLUE SHEATH. 3. ALL AO & AI WIRE SHALL BE # 20 TWISTED SHIELDED STRANDED W/ WHITE SHEATH. USE 2 OR 3 WIRE CABLE AS APPROPRIATE FOR SENSOR TYPE. BLACK WIRE SHALL DESIGNATE POSITIVE CONDUCTOR. 4. LABEL ALL WIRING IN PXC CABINET, AND AT ALL DEVICES, WITH PERMANENT BRADY COVER PLATE NI 1000 LS TEMPERATURE SENSOR 120 VAC, 60 HZ 2 1/2" CONDUIT MIN. GND H N B2 Pt 1000 385 AND Pt 1000 375 TEMPERATURE SENSOR B3 RESISTANCE-TYPE SENSOR DIGITAL INPUT WIRING EXAMPLES (TYPE LDI AND LPACI) CKT. ________ (1) (2) T B1 (NOT SANDIA FURNISHED) (3) T AS REQUIRED WHEN NECESSARY 4 4 2 T 4" 7-1/2" 5" 8 6 12 10 LATCHED OR PULSED ACCUMULATOR (NO AND NC) TYPE LABELS OR EQUAL, USING POINT DESCRIPTOR FOR EACH POINT. 4 H M B GROUND 3 3 3 4 4 4 1 5 5 5 PIP PIN GND B1 (1) (2) (3) T 1 2 (4) T 1 2 B2 5. ALL WIRING IN PXC CABINET SHALL BE NEATLY BUNDLED USING REUSABLE HOOP & LOOP TIES, TERMINATED BY CONTRACTOR AND ACCEPTED BY SANDIA INSPECTOR. 6. ALL FIELD CONDUITS SHALL BE EMT AND TERMINATE IN WIREWAY MOUNTED ABOVE OR B3 (5) T 6 1 2 BELOW PXC CABINET. MINIMUM CONDUIT SIZE BETWEEN WIREWAY AND CABINET SHALL SUPER UNIVERSAL MODULE (TXM1.8X) OR TXM1.8X-ML T LUG BE 2-1/2 INCHES. ON HINGE SIDE OF CABINET, MAKE SURE THAT CONDUIT DOES T ON 1 OFF 2 4 3 5 6 7 8 9 10 NOT INTERFERE WITH DOOR OPENING. (USE OF FLEXIBLE CONDUIT IS NOT PERMITED) ANALOG INPUT 4-20 ma 2 WIRE SENSOR WIRING EXAMPLE (TYPE LAI-2) 7 7. S5 B4 DI MODULE TXM1.16D 4-20 ma SENSOR WITH 24 VAC SUPPLY BY MODULE (6) (7) 4 2 8 6 CIRCUIT STATUS CONTACT (N/O) K2 STATUS CONTACT (N/C) K3 PULSED ACCUMULATOR (N/O) K4 PULSED ACCUMULATOR (N/C) S5 ELECTRONIC SWITCH (RATED FOR 30V) 12 10 7 CODE. (8) 8. 16 14 COIL 2' OF BUILDING LEVEL NETWORK (BLN) COMMUNICATIONS TRUNK CABLE IN LOWER RIGHT OF PXC CABINET. CONNECTION SHALL BE MADE BY FCS PERSONNEL. 11 9. T DEVICE CABLE SHIELDS TO BE TERMINATED AT GROUND TERMINATION STRIP. V TERMINATION TO BE IN PXC CABINET. SEE KEYED NOTE 2 . 8 10. B4 NOTE: TRANSFORMER SHALL BE ANALOG INPUTS, EXTERNALLY MOUNTED IN FIELD (NOT PHYSICALLY ALL DEVICES RESIDING ON THE BUILDING LEVEL NETWORK SHALL BE CONNECTED IN A DAISY CHAIN FASHION. NO STUBS OR TEES ARE PERMITTED. SUPER UNIVERSAL MODULE (TXM1.8X or TXM1.8XML) 11. MOUNTED TO FID CABINET) CABLE FOR BUILDING LEVEL NETWORK SHALL BE #24 AWG TWISTED LOW CAP SHEILDED PAIR (LESS THAN 6uf/FT.) W/ORANGE PLENUM RATED SHEATH. BLACK CONDUCTOR TO ANALOG INPUT 4-20 ma 3 WIRE SENSOR WIRING EXAMPLE (TYPE LAI-3) DESIGNATE NEGATIVE. NO OTHER WIRING SHALL BE RUN IN THE SAME CONDUIT WITH BLN WIRES. 120 V CIRCUITS 8 4-20 ma SENSOR WITH EXTERNAL 24 VAC SUPPLY (5) 4 2 8 (6) T B5 (7) T MULTIPLE TRANSFORMER OPTION 8 6 NH NH 12 10 7 12. (8) T ANALOG OUPUTS, DGITAL INPUTS 1 20 V (5) T DIGITAL OUTPUTS, 10 K1 CLASS I REMOTE CONTROL CIRCUITS SHALL NOT BE RUN IN THE SAME RACEWAY AS CLASS 2 POWER LIMITED CIRCUITS PER ARTICLE 725-52 OF THE NATIONAL ELECTRIC T K4 T K3 T K2 T K1 TXIO MODULE PLACEMENT INSTRUCTIONS PXC CABINET A. A TXIO BUS CONNECTION MODULE SHALL BE MOUNTED AT THE TOP OF EACH 16 14 DIN RAIL. SEE KEYED NOTE 6 . 11 DIGITAL OUTPUT WIRING EXAMPLES (TYPE LDO) N H T B. OUTPUT MODULE PLACEMENT SHALL START AT UPPER LEFT DIN T V RAILAND AND PROCEED IN AN DECENDING ORDER ON DIN RAIL TOWARD LATCHED CONTACTS (NO AND NC) THE BOTTOM OF THE CABINET. B5 C. INPUT MODULE PLACEMENT SHALL START AT UPPER RIGHT DIN RAIL 96VA AC / DC 24 . . .230V T3 4 AMP CIRCUIT 9 FLN TRUNK BREAKER MAX. (2) D. MAXIMUM OF 8 TXIO MODULES ALLOWED PER DIN RAIL. 4 2 3 10 8 ANALOG INPUT 0-10 VDC SENSOR WIRING EXAMPLE (TYPE LAI-4) 9 13. PROCESSOR DIGITAL OUTPUT MODULE (TXM1.6R or TXM1.6R-M) IN SEPARATE ENCLOSURE B6 0-10V SENSOR WITH EXTERNAL 24 VAC SUPPLY B7 0-10V SENSOR WITH 24 VAC SUPPLY BY MODULE Q2 TERMINAL STRIPS-LOW VOLTAGE ONLY 5 WIRING OF FLOOR LEVEL NETWORK (FLN) DEVICES : A. DEVICES RESIDING ON FLN SHALL BE CONNECTED IN A Q1 COMMUNICATION ADPATOR (1) (5) (6) T T2 (7) T 10 T1 AND PROCEED IN DECENDING ORDER TOWARD THE BOTTOM OF THE CABINET. SUPER UNIVERSAL MODULE (TXM1.8X or TXM1.8XML) 4 2 (8) T 96VA 8 6 12 10 7 DAISY CHAIN FASHION (SAME AS THE BUILDING LEVEL NETWORK). T 96VA 16 14 B. UP TO 3 FLN NETWORKS CAN BE CONNECTED TO ONE CONTROLLER. 11 C. UP TO 32 DEVICES CAN BE CONNECTED TO EACH FLN NETWORK. S RUN FLT BAT COM TX RX SIEMENS TX RX1 RX2 RX3 PXX-485-3 PXC100-PEA 2 S - + 3 S - + T RUN V V - T + T 1 T1 N T1 T2 T2 N H T3 N H D. FLN'S WITH VFC'S SHALL NOT CONTAIN OTHER TYPES OF DEVICES. T3 B6 H B7 E. FLN 24V POWER WIRING SHALL BE #14 TYPE THHN OR TFFN PINK/PURPLE. TXS1EF4 CS CD PURPLE CONDUCTOR TO DESIGNATE NEGATIVE (COMMON). A MAXIMUM OF 5 SUPER UNIVERSAL MODULE (TXM1.8X or TXM1.8X-ML) 4A TERMINAL EQUIPMENT CONTROLLERS SHALL BE ALLOWED PER POWER CIRCUIT. FLN COMMUNICATION CABLE SHALL BE THE SAME TYPE USED FOR THE BUILDING LEVEL NETWORK. SEE KEYED NOTE 11 . ANALOG OUTPUT WIRING EXAMPLES (TYPE LAOV AND LAOI) F. FLN COMMUNICATION CABLE, 24V DEVICE POWER, ACTUATOR AND SENSOR CABLE MAY BE RUN INSIDE EMT CONDUIT, OR RUN IN FREE AIR ABOVE ALL CABLE RUN IN FREE AIR SHALL BE PLENUM RATED PER THE NATIONAL ELECTRICAL CODE, AND SUSPENDED USING ARLINGTON Y2 Y3 CABLE RUNS SHALL BE LOCATED AS HIGH AS POSSIBLE IN CEILING SPACES AND RUN IN STRAIGHT LINES WHEREVER V POSSIBLE. CABLE RUNS SHALL MAINTAIN A 4INCH CLEARANCE Y1 Y4 Center ( FMOC) . 24 VAC or 24 VDC EXTERNALLY POWERED 1. 16 11 DC 24 Y4 14 T 24 VDC INTERNALLY POWERED 12 T Y3 10 T 24 VAC INTERNALLY POWERED CEILINGS AND IN WALLS, PROVIDED THE FOLLOWING CRITERIA ARE MET: (8) TL-20P CABLE SUPPORTS WITH A MAXIMUM SPACING OF 8 FEET. T Y2 8 6 7 T GENERAL POWERED DEVICE WITH CONTROL 0-10 VDC (or 4-20 mA, SUPER UNIVERSAL POINTS 5-8 ONLY) 4 (7) V NONE T Y2-Y4 SCALE: 2 (6) T TO DEVICES 3 (5) T PROGRAMMABLE EXPANDABLE CONTROLLER PXC DIAGRAM ACTUATOR WITH CONTROL INPUT ONLY, 0-10 VDC (or 4-20 mA, SUPER UNIVERSAL, POINTS 5-8 ONLY) T Y1 FROM ALL OBSTACLES. CABLE SUPPORTS SHALL BE INSTALLED PER SANDIA NATIONAL LABORATORIES ELECTRICAL STANDARDS. SUPER UNIVERSAL MODULE (TXM1.8X or TXM1.8X-ML) 2. FLN COMMUNICATION CABLE SHALL BE THE SAME TYPE SPECIFIED FOR THE BUILDING LEVEL NETWORK. 3. ONLY FLN ROOM SENSOR CABLE MAY BE RUN VERTICALLY IN WALLS PROVIDED A CABLE SUPPORT IS USED AT THE HORIZONTAL RETURN AIR HUMIDITY 1 LAI-3 11 5 PREHEAT TEMP 0860.E.CH03.TD05 2. CONFIGURE MODULE LAYOUT PER GENERAL NOTE 12 USING MODULE LABELING DETAIL TO RIGHT. 860.E.CH03.TD03 2 CHILLED WATER COIL TEMP TSM1.8X 3 3. PLACE PXC PANEL, FEED PANEL, AND CKT NUMBER IN HEADER FIELD IN UPPER MIN OSA FLOW LEFT CORNER OF SPREDSHEET. 0860.A.AH01.TD01 PLACE PXC PANEL DESIGNATION IN FOOTER FIELD AT BOTTOM CENTER OF EXPANSION CABINET. USE EXISTING KOCKOUT LOCATED AT UPPER RIGHT HAND LAI-2 SIDE OF CABINET. PXC CABINET DOES NOT PROVIDE 120V POWER FOR EXTERNAL TRANSFORMERS OR 24V DEVICE POWER. SEE KEYED NOTE 8 7 A AH01TD01 LAI-1 AI INTERFERES WITH WALL SWITCH, MOUNT THERMOSTAT BETWEEN 48"AND 60" MAXIMUM. 2 NOT USED 3 PXC ENCLOSURE AND INTERNAL COMPONENTS ARE SANDIA FURNISHED EQUIPMENT CONTROLLED DEVICE STARTER. RIB RELAYS SHALL BE MOUNTED IN A MANOR (SFE) CONTRACTOR SHALL MOUNT PXC AND TERMINATE POINTS ACCORDING TO LAYOUT. SO THE INDICATOR LIGHT IS VISIBLE AT THE DISCONNECT/STARTER DEVICE. 16. LAI-2 ALL THERMOSTATS SHALL BE MOUNTED WITHIN 4" OF THE DOOR JAMB, ON THE SIDE OPPOSITE THE DOOR HINGES, AT A HEIGHT OF 48". IF THE PLACEMENT OFTHERMOSTAT LAI-2 MODULE WIRING DETAIL: SEE DETAILS THIS SHEET SPREADSHEET PER LABELING DETAIL BELOW. MODULE TYPE AI, DI, AO, DO 15. . 8 TEMPERATURE KEEP ALL MBC CABINETS A MINIMUM OF 5' (1 .5 METERS) AWAY FROM POWER SOURCES GREATER THAN 1 00 KVA AND ANY VARIABLE FREQUENCY CONTROLLERS. TERMINAL STRIPS PIP, PIN, FUSE, AND GND FOR CONNECTION OF 24VAC POWER AIR HANDLER SUPPLY 4 4. 1 0858.A.AH01.TD01 ML LAI-4 MIXED AIR TEMPERATURE DESCRIPTION 6 RETURN AIR TEMPERATURE LAI-3 0860.A.AH01.FA01 14. LAI-1 LOCATION OF (RIB) RELAYS SHALL BE MOUNTED AS CLOSE AS POSSIBLE TO THE MODULE PART NUMBER 4 CONNECT POWER PER MANUFACTURER'S INSTRUCTIONS. 5 FLN CONNECTORS LOCATED ON LEFT SIDE OF INSTALLED PROCESSOR. 6 EXCEL SPREADSHEET MODULE LABELING DETAIL D 6/17/05 UPDATE ELG MFR TXIO BUS CONNECTION MODULE. SEE KEYED NOTE 9 FOR WIRING INSTRUCTIONS. C 2/10/05 UPDATE ELG MFR 7 POINT MODULE ADDRESS KEY (TYPICAL). E 03/17/06 UPDATE EG MFR 8 EXTERNALLY MOUNT 24 VAC UL CLASS II RATED TRANSFORMER(S) AND LINE SIDE A EG MFR DWN CKD SCALE: NONE PXC A TWO SPACES FID CABINET DESIGNATION LETTER ("A", "B", "C", ETC.) DISCONNECT TO PROVIDE POWER TO VALVES, ACTUATORS AND EQUIPMENT PXC P.O. CONTROLLERS. TRANSFORMERS SHALL BE NO LARGER THAN 96 VA. MAXIMUM LOAD PER TRANSFORMER NOT TO EXCEED 80 VA. CIRCUIT BREAKER TO BE RATED AT BUILDING NUMBER 2/28/12 UPDATE REV DATE DESCRIPTION APP PROJECT NO. 4 AMPS MAX. IF MORE THAN ONE TRANSFORMER IS NECCESSARY, BALANCE THE U.S. DEPARTMENT OF ENERGY LOADS. DEVICE 24 VOLT POWER WIRING TYPE SHALL BE #14 THHN OR TFFN PINK/PURPLE. PURPLE CONDUCTOR TO DESIGNATE NEGATIVE (COMMON). A SINGLE EXCEL FILE LABELING DETAIL NNSA/SANDIA SITE OFFICE ALBUQUERQUE, NEW MEXICO PINK/PURPLE PAIR MAY BE USED TO POWER MULTIPLE DEVICES. SANDIA NATIONAL LABORATORIES 9 TXIO POWER SUPPLY MODULE TO BE WIRED TO BUS CONNECTION MODULES. REFERENCE PXC DIAGRAM UPPER LEFT HAND CORNER THIS SHEET FOR WIRING CONNECTIONS. USE FID MODULE WIRING DETAILS & PXC CABINET DETAIL P.O. 0839422 #18 AWG 4 WIRE CABLE W/WHITE SHEATH. PROJECT NO. 10 24 VAC POWER FOR PXC PROCESSOR, COMM ADAPTORS & TXIO MODULE POWER DRAWN BY E. L. GORE CHECKED BY D. J. DOBIAS SNL ENGR C. A. EVANS DATE 1 0/1 2/99 SUPPLIES ONLY. SHALL NOT BE USED TO POWER EXTERNAL DEVICES. SEE KEYED NOTES 1 & 8. MECHANICAL SIZE OLD FILENAME: FILENAME: MI5001 STD.DGN STANDARD A Joint Venture DRAWING NO of SCALE: NONE " Property BLDG 858 SEQ. D+ MI5002STD 4-21-1999 FMOC. " ON CONSTRUCTION DRAWINGS. KEYED NOTES 0860.E.AH03.TD02 of FOR DESIGN OF FID (FIELD INTERFACE DEVICE) CABINET. THIS INFORMATION IS NOT TO BE PLACED 0860.E.AH03.HD01 expressed authorization CONTACT FACILITIES CONTROL SYSTEMS, ORG. 4844 FOR EXCEL SPREADSHEET TEMPLATE FILE al l ow ed w ithout the G. FOR TERMINATION OF TEC WIRING, CONSULT FACTORY WIRING DIAGRAMS. 1. al teration CABLE RUNS INSIDE WALLS MUST BE INSIDE EMT CONDUIT. POINT NUMBER ADDRESS KEY NUMBER No FID LAYOUT - EXCEL SPREADSHEET INSTRUCTIONS Sandia NationalLaboratories Facil ities Managem ent and Operation TRANSITION IN THE CEILING PLENUM SPACE. ALL HORIZONTAL POINT NAME AND WIRING LABEL SECTION "A" SECTION "B" INPUTS SECTION "C" LOGICAL POINT NAME IDENTIFICATION KEY SYSTEM TYPE DESIGNATORS ARE: APOGEE FID AH AIR HANDLER BG BLDG. GENERAL (CONTROL, ALARM, ETC.) BR BOILER HW SYSTEM CB CONTAINMENT BOX CH CHILLER/CHW SYSTEM CT COOLING TOWER CV STEAM CONVERTER HW SYSTEM DX DIRECT EXPANSION COOLING UNIT EF EXHAUST FAN SYSTEM ET EVAPORATIVE TANK SYSTEM HX HEAT EXCHANGER LI LIGHTING INVERTER SYSTEM MA MAKEUP AIR SYSTEM PW PROCESS WATER SYSTEM RA RECIRCULATING AIR SC SCRUBBER SF SERVICE FAN SYSTEM TU TERMINAL UNIT ALARM, MISCELLANEOUS AB ALARM, BOILER AC ALARM, CHILLER AF ALARM, FIRE FACILITY CONTROL SYSTEM BLN BUILDING LEVEL NETWORK FLN FIELD LEVEL NETWORK PNEUMATIC CONTROL SIGNAL MBC MODULAR BUILDING CONTROLLER FLN COMMUNICATION FID FIELD INTERFACE DEVICE (MBC) VFD VARIABLE FREQUENCY DRIVE BTU BRITISH THERMAL UNITS DESCRIPTION USED ON WIRE NO NORMALLY OPEN LABELS AND CONSTRUCTION NC NORMALLY CLOSED C COMMON THESE 8 CHARACTERS FORM THE ALARM, HUMIDITY AL ALARM, LEVEL AP ALARM, PRESSURE AT ALARM, TEMPERATURE AV ALARM, VIBRATION MB METER, BTU PULSE ME METER, ELECTRIC PULSE MG METER, GAS PULSE MS METER, STEAM PULSE MW METER, WATER PULSE ST EQUIPMENT STATUS ELECTRICAL POWER SIGNAL HARDWARE NON-FLN POINTS PHYSICAL AND LAN POINT ADDRESS (APOGEE) SEPARATOR AH ELECTRICAL CONTROL SIGNAL FCS DIGITAL INPUTS (DI) AA LINE LEGEND ABBREVIATIONS XX .X .XXX .XXXX DRAWINGS SEPARATOR POINT TD01 0905 .AH01. DROP NUMBER 0-225 SYMBOL LEGEND FID"A" FLN NUMBER 0-3 FID PANEL XXXX CABINET 01 -99 POINT NUMBER (00-99) MBC CONTROL POINT (SEE NOTATION X EXPLANATION BELOW) POINT TYPE SYSTEM NUMBER XX SYSTEM TYPE WT WASTE TANK SYSTEM FLN # 0 FOR CABINET HARDWARE POINT, 1 -3 FOR FLN DEVICES DROP # 0 FOR PHYSICAL POINTS, DESIGNATES MODULE ADDRESS KEY NUMBER BUILDING NAME ANALOG INPUTS (AI) (001 -255). SEE DRAWING MI5001 STD.DGN, FID MODULE WIRING DETAILS AQ AIR QUALITY AR ALARM REFRIGERANT CU CURRENT FB FEEDBACK FQ FREQUENCY FW FLOW, WATER HD HUMIDITY, DUCT HR HUMIDITY, ROOM LT LEVEL, TANK LR LEVEL, REFRIGERANT MA AIRFLOW MEASURING STATION PA PRESSURE AIR DISPLAY OUTPUT, ANALOG PB PRESSURE BUILDING STATIC ED ELECTRONIC DAMPER MOTOR OPERATOR PS PRESSURE STEAM ES ELECTRONIC SPEED CONTROL (VFC) PW PRESSURE WATER EV ELECTRONIC VALVE OPERATOR PH WATER PH ER ELECTRONIC RESET PR PRESSURE GENERAL FC FAN CAPACITY CONTROL (BLADE/VANE PITCH) SP SETPOINT, DIAL PNEUMATIC DAMPER OPERATOR TD TEMPERATURE, DUCT POINT TYPE DESCRIPTIONS OUTPUTS X CONTROL EQUIPMENT TAG X MECHANICAL EQUIPMENT TAG M GAS METER & MBC CABINET DETAIL FOR MORE INFORMATION. FOR FLN DEVICE, DESIGNATES LAN DEVICE ADDRESS (001 -099). POINT # FOR PHYSICAL POINTS, DESIGNATES THE LOCATION OF THE POINT IN THE MODULE. MODULES CAN HAVE 1 TO 4 POINTS DEPENDING ON THE TYPE. POINTS ARE ADDRESSED FROM RIGHT TO LEFT IN DIGITAL OUTPUTS (D0) INSTRUMENTATION/ CONTROL DEVICE XX VARIABLE FREQUENCY DRIVE VFD A MODULE. FOR FLN DEVICES, DESIGNATES THE FLN DEVICE POINT ADDRESS (001 -099). OC OPEN/CLOSE CONTROL SS START/STOP OR ON/OFF CONTROL HARDWARE FLN NAMES (APOGEE) SEPARATOR ANALOG OUTPUTS (AO) PANEL TYPE MBC, MEC OR TEC DESCRIPTION ASSIGNED BY APOGEE SOFTWARE DEVICE NUMBER (EX. 0065) AH12FA01 MBC FLN DEVICE TYPE X FID DESIGNATOR POINT NUMBER BUILDING NUMBER POINT TYPE PS PNEUMATIC SEQUENCING CONTROL TG TEMPERATURE, GAS PV PNEUMATIC VALVE TR TEMPERATURE ROOM SYSTEM NUMBER TT TEMPERATURE, TANK SYSTEM TYPE TW TEMPERATURE, WATER WX WEATHER STATION FLOOR LEVEL NETWORK (FLN) DEVICE TYPES FID DESIGNATION NOTE: POINT DESIGNATOR TO BE ON TOP LEFT OR RIGHT OF CONTROL POINT SYMBOL. VIRTUAL TIMERS (APGOEE) VIRTUAL POINT NAME (APOGEE) LOC LABORATORY OFFSET CONTROLLER VAV VARIABLE AIR VOLUME VFC VARIABLE FREQUENCY CONTROLLER RPM ROOM PRESSURIZATION MONITOR SLC SLAVE CONTROLLER DEM DIGITAL ENERGY MONITOR SEPARATOR 0905 .X .AH01 .SECND .S 0905 .X . AH01.S 01 1-99 TIMER NUMBER VIRTUAL POINT TYPE # 01 -99 DESIGNATES DEVICE SEE SECTION A IS A TIMER VIRTUAL POINT TYPE SEE SECTION A SYSTEM TYPE AND NUMBER. SYSTEM TYPE AND NUMBER. SEE SECTION A SEE SECTION A FOR SITE SPECIFIC SYSTEMS NOT IN THIS LIST, CONTACT SNL FCS ORG. 1 0848. FID DESIGNATOR FID DESIGNATOR BUILDING NUMBER BUILDING NUMBER VIRTUAL POINT TYPE KEY (CONT'D) G = MISC GAIN H = HOLIDAY J = SSTO VARIABLE K = ELECTRICAL USAGE (KWH) L = LEAD/LAG/STANDBY SELECTOR M = ENHANCED ALARM MODE PTS N = NIGHT VENT O = OUTSIDE AIR VALUES Q = AUTODIAL DISABLE R = (OPEN) S = SETPOINTS T = MIN/MAX/AVG TEMPS, ETC U = (OPEN) V = VIRTUAL LDO STATUS W = WEEKEND X = CALCULATED VALUES (CONT'D.) VIRTUAL POINT TYPE KEY A = ALARMS B = BLDG/SYS RUN CONTROL C = CALCULATED VALUES D = DEMAND POINTS E = ENTHALPY F = FLOW C 11/2005 REVISED ELG MFR B 10/2001 REVISED ELG MFR A 8/2001 AS BUILT ELG FCS P.O. REV DATE DESCRIPTION DWN CKD APP PROJECT NO. U.S. DEPARTMENT OF ENERGY NNSA/SANDIA SITE OFFICE ALBUQUERQUE, NEW MEXICO SANDIA NATIONAL LABORATORIES P.O. FCS Point Descriptions PROJECT NO. Standards DRAWN BY CHECKED BY SNL ENGR DISCP: OLD FILENAME: FILENAME: M SUB-DISCP: STD SIZE MI6002STD.DGN MI6002STD.dgn I A Joint Venture D+ DATE DRAWING NO MI6002STD 08/17/2001 SEQ. FMOC. " FUME HOOD CONTROLLER of FHC SEPARATOR expressed authorization FAN COIL CONTROLLER al l ow ed w ithout the FCU al teration CONSTANT VOLUME EXHAUST No (FOR PROGRAMMING USE ONLY) CVE Sandia NationalLaboratories Facil ities Managem ent and Operation Center ( FMOC) . TERMINAL EQUIPMENT CONTROL DEVICES of PD CONTROL POINT NOTATION " Property DA UP TO 1 2 0905 .X .VAV .XXXX :CHARACTERS OFFICIAL USE ONLY CONTROL EQUIPMENT SCHEDULE SYMBOL 1 DESCRIPTION SYMBOL DIFFERENTIAL PRESSURE SWITCH: COMPLETE ASSEMBLY FOR SENSING VARIATION IN AIR PRESSURE AT FANS. CONSTRUCTION EQUIVALENT TO POWERS SW141 35 DESCRIPTION LIQUID LEVEL CONTROL ASSEMBLY: COMPLETE ASSEMBLY FOR TOWER RESERVOIR LEVEL CONTROL, INCLUDING CLAYTON CF-1 FLOAT CONTROL WITH FLOAT SERIES. RANGE TO MATCH FAN BEING SERVED. THE DIFFERENTIAL PRESSURE SWITCH CONTACTS SHALL CLOSE ON A RISE IN DIFFERENTIAL PRESSURE ROD, FLOAT LINKAGE, MULTI-PORT PILOT VALVES, AND ALL ACCESSORIES FOR A COMPLETE INSTALLATION. THE FLOAT ASSEMBLY SHALL OPERATE AS (ADJUSTABLE SWITCHING POINT). PART OF THE LEVEL CONTROL SYSTEM W/A CLAYTON 100P NORMALLY-CLOSED POWER CONTROL VALVE. WHEN FLOAT DROPS, THE VALVE SHALL OPEN TO ALLOW FILL WATER INTO THE RESERVOIR. OPERATING FLUID SHALL BE CONTROL AIR PRESSURE AT 20 PSIG. THE 100P VALVE SHALL BE 2-INCH 2 DIFFERENTIAL PRESSURE SWITCH: COMPLETE ASSEMBLY FOR SENSING VARIATION IN WATER PRESSURE TO BE USED TO SENSE WATER PRESSURE AT CIRCULATION PUMPS. CONSTRUCTION EQUIVALENT TO DWYER SERIES BB-521-3-6S RANGE 3-40 PSIG, THE DIFFERENTIAL PRESSURE SWITCH CONTACTS GLOBE VALVE. THE VALVE SHALL HAVE 2 OPERATING CHAMBERS SUCH THAT PRESSURE APPLIED TO THE UPPER CHAMBER SHALL CLOSE THE VALVE, AND SHALL CLOSE ON A RISE IN DIFFERENTIAL PRESSURE TO 10 PSIG (ADJUSTABLE SWITCHING POINT). FURNISH WITH SENSING FITTINGS. ROOT VALVES PRESSURE APPLIED TO THE LOWER CHAMBER SHALL OPEN THE VALVE. 37 SENSOR - DUCT (AVERAGING ELEMENT) TEMPERATURE: POWERS ANALOG RTD. PRODUCT NO. 533-380, PLUS 20-DEGREES F TO PLUS 120-DEGREES F RANGE, 70 NOT USED 71 CONTROL VALVE: VALVE AND ACTUATOR TO BE FACTORY ASSEMBLED. ASSEMBLY PROD. NO. 274-03134 ELECTRIC LEVEL CONTROL ASSEMBLY: FOR COOLING TOWER RESERVOIR, COMPLETE ASSEMBLY INCLUDING LEVEL SENSOR AND PROBES, AS WELL AS VALVE: TWO-WAY, EQUAL PERCENTAGE FLOW, NORMALLY CLOSED, BRONZE BODY, STAINLESS STEEL TRIM, NORMAL DUTY PACKING, EPDM O-RING, DIRECT COUPLED SOLENOID CONTROL VALVES. THE SYSTEM SHALL HAVE A HIGH LEVEL SENSOR TO CLOSE MAKE-UP VALVE, A MIDDLE SENSOR TO OPEN MAKE-UP VALVE, UNIVERSAL BONNET GLOBE VALVE. FEMALE NPT CONNECTIONS. A LOW LEVEL SENSOR TO ALARM THRU THE PCC, AND A HIGH LEVEL "OVERFLOW" SENSOR ALSO FOR ALARM TO THE PCC (PLANT CONTROL CENTER). SIEMENS FLOWRITE VF 599 SERIES - 2" Cv = 40 FURNISH ALL RELAYS ELECTRODES, HOLDERS, FOR A COMPLETE LEVEL SENSING SYSTEM. UNIT SHALL BE B-W "FLOATLESS LIQUID LEVEL". THE ACTUATOR: ELECTRONIC VALVE ACTUATOR, PROPORTIONAL CONTROL, 24 VAC OPERATING, 0-10 VDC CONTROL INPUT, 0-10 VDC CONTROL OUTPUT, SPRING FLOW MEASURING STATION SIGNAL TRANSMITTER: SETRA MODEL C239, 0.14 PERCENT ACCURACY, SELECT RANGE TO MATCH ASSOC. VEL0CITY PROBE. MAKE-UP VALVE PART OF THE ASSEMBLY SHALL BE A CLAYTON 136-01, 2-INCH SIZE SOLENOID CONTROL VALVE, N.C. UNTIL SOLENOID IS ENERGIZED. RETURN TO FAIL SAFE, MANUAL OVERRIDE,4" STROKE. MOUNT IN VAV CONTROL CABINET. THIS DIFFERENTIAL PRESSURE TRANSMITTER SHALL HAVE A 4-20 maDC OUTPUT SIGNAL. THIS DEVICE MEASURES SOLENOID SHALL BE 120 VOLT, AND FURNISHED WITH VALVE. VALVE SHALL BE SCREWED, BRONZE CONSTRUCTION, 150 PSIG, W.P. CONSTRUCTION. 4-20 maDC OUTPUT SIGNAL, WITH DUCT MOUNTING FLANGE AND J-BOX FOR CONDUIT ATTACHMENT. PLATINUM ELEMENT. 4 NOT USED SIZE, SCREWED, BRONZE CONSTRUCTION, 150 PSIG W.P. DESIGN. VALVE SHALL BE DIAPHRAGM OPERATED, SINGLE SEAT, PNEUMATICALLY OPERATED FOR ISOLATION SHALL BE NUPRO BALL VALVE WITH 1/4-INCH FLARE ADAPTER. MAXIMUM WORKING PRESSURE 100 PSIG. 3 69 3 SIEMENS FLOWRITE EA 599 SERIES ORDER NO. SKD62U VELOCITY PRESSURE. 5 NOT USED - SEE 38 ELECTRIC-PNEUMATIC RELAY: POWERS 267-1002, 120V-1PH-60CY COIL, WALL-MOUNTING BRACKET, 3-PIPE, SPLICE BOX FOR ELECTRICAL CONNECTIONS. 39 PNEUMATIC ELECTRIC SWITCH: 3-13 PSIG WITH 1-DPST AND 1-SPST PRESSURE ACTUATED SWITCHES, 5A AT 120 VAC RESISTIVE RATING. CONTACTS 53 72 VALVE: BUTTERFLY VALVE, POLYESTER COATED CAST IRON BODY, FULL LUG PATTERN SUITABLE FOR BI-DIRECTIONAL DEAD END SERVICE, ANSI CLASS 125/150, MAKE ON PRESSURE RISE. ADJUSTABLE DEAD BAND 12 PSIG, MINIMUM REQUIRED. POWERS SW134, OR EQUAL. SURFACE MOUNTED. 6 THROUGH STEM DIRECT DRIVE DISC DESIGN, TONGUE AND GROOVE RESILIENT SEAT. BUBBLE TIGHT TO FULL VALVE PRESSURE RATING VALVE INSTALLED ON TEMPERATURE SENSOR - LIQUID IMMERSION: POWERS #531-453 ANALOG UNIT, PLUS 70 DEGREES F TO 220 DEGREES F RANGE, 4-20 INSULATED SERVICES SHALL BE PROVIDED WITH EXTENSIONS, AS REQUIRED, SUCH THAT OPERATOR DOES NOT INTERFERE WITH INSULATION OR INSULATION maDC OUTPUT SIGNAL. FURNISH WITH SEPARABLE SOCKET, STAINLESS STEEL WELL, ELECTRICAL CONNECTION BOX. ACCURATE TO +1 DEGREE F. 7 - 40 ANALOG SENSOR - ROOM TEMPERATURE: 4-20 maDC OUTPUT SIGNAL, PLUS 40 DEGREES F TO 90 DEGREES F RANGE, 70 DEGREES F CALIBRATION POINT. FURNISH WITH "POWERSTAR" COVER AND ALL NECESSARY INSTALLATION FITTINGS, PLUS OR MINUS 0.5 DEGREES F ACCURACY, RTD ELEMENT STATIC PRESSURE PROBE: FURNISH AND INSTALL STATIC PRESSURE TRAVERSE PROBES FOR CONTINUOUSLY MONITORING THE STATIC PRESSURE WHERE JACKETING. INSTALLED. EACH SHALL CONTAIN STATIC PRESSURE SENSORS, INTERNALLY CONNECTED TO AVERAGING MANIFOLDS. CONSTRUCTED OF EXTRUDED BRAY 8" SERIES 31 VALVE ALUMINUM OR STAINLESS STEEL WITH ALL THREADS, NUTS, MOUNTING HARDWARE, GASKETS, AND SUPPORT BRACKETS, ETC. FOR A COMPLETE ACTUATOR: 0-10 VDC MODULATING, 120 VAC POWERED, SELF LOCKING SPUR GEAR TRAIN WITH WORM GEAR, SPDT TRAVEL SWITCHES, INFINITELY ADJUSTABLE INSTALLATION. AIR MONITOR STAT-PROBE/1. CAM SWITCHES, STAINLESS STEEL TRAVEL STOPS, MANUAL OVERRIDE HAND WHEEL WITH EMERGENCY SHUTOFF, VALVE STATUS INDICATOR. ACTUATOR SHALL BE POWERS NO. 536-200 SIZED TO EXCEED THE MAX TORQUE REQUIREMENTS OF THE VALVE. 41 8 CONTROL VALVE: VALVE AND ACTUATOR TO BE FIELD ASSEMBLED IN NORMALLY OPEN OR NORMALLY CLOSED POSITION AS SHOWN ON DRAWINGS. TWO-WAY HOT WATER VALVE: HONEYWELL N.O. 125 PSIG VALVE BODY AND PNEUMATIC OPERATOR V5011A BODY, MP953C OPERATOR, 3-7 PSI SPRING RANGE, ZONE CONTROL CABINET: COMPLETELY FACTORY ASSEMBLED AIR MONITORING STATION IN A NEMA-1 ENCLOSURE. PANEL COMES COMPLETELY PIPED WITH BRAY SERIES 70 R4 ACTUATOR EXTERNAL 1/4-INCH BULKHEAD TUBE FITTINGS. INCLUDES MOUNTING, PIPING AND WIRING AS A THREE OR FIVE STATION CABINET. SEE PLANS FOR SIZES (3/4-INCH - 2-INCH SCREWED AND 2-1/2 INCH - 6-INCH FLANGED BODY), EQUAL PERCENTAGE FLOW, OPERATOR CAPACITY FOR CLOSE OFF AT 85 PERCENT OF PUMP HEAD. 42 SHIELDED STATIC AIR PROBE: AIR MONITOR SAP-1, 10 GA., WELDED ALUMINUM, SENSING CHAMBER, CAPABLE OF SENSING PLENUM PRESSURE WITHIN 1 73 VALVE: TWO-WAY, EQUAL PERCENTAGE FLOW, NORMALLY OPEN, FLANGED IRON BODY, STAINLESS STEEL TRIM, NORMAL DUTY PACKING, EPDM O-RING, PERCENT OF ACTUAL. LOCATE INSIDE BUILDING ABOVE CEILING PLENUM, OR AS NOTED ON DRAWINGS. 9 DIRECT COUPLED UNIVERSAL BONNET, ANSI CLASS 125 GLOBE VALVE. VOLUME/VELOCITY PROBE: FURNISH AND INSTALL AIR FLOW TRAVERSE PROBES FOR CONTINUOUSLY MONITORING THE FAN AIR VOLUMES AT FAN INLETS. EACH SHALL CONTAIN MULTIPLE TOTAL AND STATIC PRESSURE SENSORS, INTERNALLY CONNECTED TO AVERAGING MANIFOLDS. CONSTRUCTED OF EXTRUDED 43 SIEMENS FLOWRITE VF 599 SERIES - 4" Cv = 160 NOT USED. ALUMINUM OR STAINLESS STEEL WITH ALL THREADS, NUTS, MOUNTING HARDWARE, GASKETS, AND SUPPORT BRACKETS, ETC. FOR A COMPLETE ACTUATOR: ELECTRONIC VALVE ACTUATOR, PROPORTIONAL CONTROL, 24 VAC OPERATING, 0-10 VDC CONTROL INPUT, 0-10 VDC CONTROL OUTPUT, SPRING INSTALLATION. UNITS SHALL BE SELECTED FOR THE ACTUAL FLOW, FAN SIZE AND TYPE, AIR MONITOR VOLU-PROBE FI (NO SUBSTITUTIONS). RETURN TO FAIL SAFE, MANUAL OVERRIDE,4" STROKE. 3 44 10 CONTROL VALVE: VALVE AND ACTUATOR TO BE FACTORY ASSEMBLED. ASSEMBLY PROD. NO. 294-05962 TWO-WAY CHILLED WATER VALVE: HONEYWELL N.O. 125 PSIG VALVE BODY AND PNEUMATIC OPERATOR V5011 BODY MP953C OPERATOR, 8-13 PSIG SPRING SIEMENS FLOWRITE EA 599 SERIES ORDER NO. SKC62U VACUUM ALARM SWITCH: ADJUSTABLE RANGE AND SET POINT TO MAKE ALARM CIRCUIT ON VACUUM LOSS. MOUNT IN PIPE WELL. SET TO MAKE AT 5-INCH H.G. VACUUM. MERCOID DA-31-153-2 OR EQUAL. RANGE 0-30" HG. VAC. RANGE, SEE PLANS FOR SIZES (1/2-INCH THRU 2-INCH SCREWED 2 1/2-INCH AND LARGER FLANGED). OPERATOR CAPACITY FOR SHUT-OFF AGAINST 45 PROCESS PUMP TOTAL HEAD (APPROXIMATELY 60 PSIG). FLOW SWITCH: MCDONNEL-MILLER SPDT SWITCH. ACTUATED BY BRASS PADDLE (IN FLOW STREAM NO MORE THAN 1.5 INCHES FROM OPPOSITE WALL OF 74 11 E SIEMENS NO. 533-380 NOT USED. 46 PNEUMATIC GRAD. SWITCH: POWERS MODEL SW151-143 BLEED TYPE POSITIONING SWITCH WITH SURFACE MOUNTING KIT AND ALL HARDWARE. TO CONTROL OUTPUT PRESSURE FROM 0 TO 30 PSIG. 12 DUCT TEMPERATURE SENSOR: 100 OHM PLATINUM RTD ELEMENT, 20 TO 120 DEG. F MONITORING RANGE, +/- 0.7 DEG. F ACCURACY, ZERO AND SPAN CALIBRATION, 4-20 mA OUTPUT SIGNAL, 25 FT. AVERAGING ELEMENT. PIPE). FURNISH WITH ALL FITTINGS. MODEL FS7-4, 7.4 AMPS AT 120 VAC, WITH 20 SECOND TIME DELAY. 75 CONTROL RELAY CONTACTS SHALL BE RATED FOR 150% OF THE LOADING APPLICATION, WITH SELF-WIPING, SNAP-ACTING SILVER CADMIUM FORM C CONTACTS, ENCLOSED IN DUST PROOF ENCLOSURE. RELAYS SHALL BE EQUIPPED WITH THE NECESSARY MOUNTING BASE, DIN RAIL, LABELS, TERMINATION CLIPS, ETC. AND A COIL TRANSIENT SUPPRESSION DEVICES. ALL RELAYS FOR CONTROL BY THE FMS SHALL HAVE 24 VAC COILS. 76 CURRENT SENSOR: SOLID-STATE, ADJUSTABLE SET-POINT, SELF-INDUCED POWER, NON-POLARITY SENSITIVE OUTPUT, SPLIT-CORE MOUNTING. VERIS INDUSTRIES NO. H-608. 77 IMMERSION TEMPERATURE SENSOR: 100 OHM RTD ELEMENT, 32 TO 212 DEG.F. MONITORING RANGE, +/-1.0 DEG.F. ACCURACY, ZERO AND SPAN CALIBRATION, 4-20 MA OUTPUT SIGNAL. FURNISH WITH IMMERSION WELL. SIEMENS/ LANDIS NO. 544-562-25. 78 TWO-WAY ELECTRONIC VALVE: 1", NORMALLY OPEN, EQUAL PERCENTAGE FLOW, BRONZE TRIM, NORMAL DUTY PACKING, STAINLESS STEEL STEM, ANSI 250, CV=10, WITH 0-10 VDC ELECTRO-HYDRAULIC MODULATING ACTUATOR. SIEMENS/ LANDIS NO. 291-03167. 79 LEVEL TRANSMITTER: FLUSH DIAGPHRAGM SUBMERSIBLE TYPE, G1/2 WITH STEEL CAGE PROCESS CONNECTION, INCHES H2O PRESSURE UNITS, 25' CABLE LENGHT, 4-20 MA OUTPUT, 316 SST SENSOR, 304 SST HOUSING, & KYMAR CABLE, 0 TO 5.77 FT RANGE. AST NO. AST4520Y0002.5H41353. 80 CONTROL VALVE: 1/2", 2-WAY, 2 POSITION SPRING RETURN ACTUATOR, NORMALLY CLOSED BALL VALVE, CV= 0.4, BRASS STEM AND BODY, NICKLE PLATED BRASS BALL, GLASS FILLED POLYMER FLOW OPTIMIZER, EDPM O-RING SEALS, 24 VAC ACTUATOR. SIEMENS NO. 171H-10300. 81 CONTROL VALVE: 1/2", 2-WAY, 2 POSITION SPRING RETURN ACTUATOR, NORMALLY CLOSED BALL VALVE, CV= 2.5, BRASS STEM AND BODY, NICKLE PLATED BRASS BALL, GLASS FILLED POLYMER FLOW OPTIMIZER, EDPM O-RING SEALS, 24 VAC ACTUATOR. SIEMENS NO. 171H-10304. 82 STATUS LIGHT: MINI-SQUARE BEACON, NEMA 4/13, AMBER LED LENSE, 24 VAC POWER. UNIT SHALL INCLUDE NAMEPLATE STATING "CONDENSATE PUMP ALARM". ALLEN-BRADLEY MODEL 855B-GMS24R5. ANALOG SENSOR - ROOM RELATIVE HUMIDITY: POWERS SYSTEM INCLUDING HUMIDITY SENSOR AND HOUSING AND TRANSMITTER (SEPARATE UNIT), 0-100 PERCENT RH HUMIDITY RANGE, 4-20 maDC OUTPUT SIGNAL, PLUS OR MINUS 2 PERCENT RH ACCURACY; FURNISH WITH ALL NECESSARY INSTALLATION 47 FITTINGS, PLUS/MINUS 6 PERCENT RH FULL RANGE, PLUS/MINUS 2 PERCENT RH OPTIONAL OVERSPANS NO GREATER THAN 25 PERCENT BETWEEN 5 PERCENT STATIC PRESSURE METER: DWYER 2000 FACTORY CALIBRATED STATIC PRESSURE METER. RANGE TO MATCH RANGE OF STATIC TRANSMITTER FOR WHICH IT IS TO BE SUPPLIED AS SHOWN ON DRAWINGS. METER SHALL BE 98% ACCURATE AND FULLY FIELD ADJUSTABLE TO ALLOW FOR CALIBRATION BY OWNER. AND 95 PERCENT RH. 48 13 DUCT RELATIVE HUMIDITY SENSOR: POWERS ANALOG SENSOR, 0-100 PERCENT RH HUMIDITY RANGE, 4-20 maDC OUTPUT SIGNAL, PLUS/MINUS 2 PERCENT RH 3-WAY AIR VALVE: POWERS MODEL 656-0009, HIGH CAPACITY 3-WAY PILOT VALVE. DESIGNED FOR SWITCHING OFF COMPRESSED AIR CV=2.5, SPRING RANGE 10-15 PSIG. ACCURACY CAPABILITY, FURNISH WITH ALL NECESSARY INSTALLATION FITTINGS, PLUS/MINUS 6 PERCENT RH FULL RANGE, PLUS/MINUS 2 PERCENT RH OPTIONAL OVERSPANS NO GREATER THAN 25 PERCENT BETWEEN 5 PERCENT AND 95 PERCENT RH. 14 TEMPERATURE SENSOR - LIQUID IMMERSION: PLUS 20 DEGREES F TO 120 DEGREES F RANGE, 4-20 maDC OUTPUT SIGNAL. FURNISH WITH SEPARABLE SOCKET, STAINLESS STEEL WELL, ELECTRICAL CONNECTION BOX. ACCURATE TO 1 DEG. F. POWERS #531-452 15 49 + - PRESSURE GUAGE: STEM MOUNTED, 2 INCH DIAMETER, 0 TO 30 PSIG WITH DUAL SCALE. BARBER-COLMAN NO. AL-327. 51 LOW LEVEL SWITCH FOR AIR WASHER RESERVOIR GEMS NO. A113825 WITH RELAY, STAINLESS STEEL (316) TO OPEN AT LOW LEVEL. (BY AHU VENDOR) 52 VOLUME/VELOCITY PROBE: MULTIPLE TUBE, MULTIPLE POINT, SELF-AVERAGING AIRFLOW TRAVERSE STATION. CONSTRUCTED OF 14 GUAGE THREE-WAY HOT WATER VALVE: POWERS VF 591 WM 125 PSIG VALVE BODY AND ACTUATOR, 4-8 PSIG SPRING RANGE, SEE PLANS FOR SIZES (1/2-INCH THRU 2-INCH SCREWED, 2-1/2 INCH AND LARGER FLANGED). OPERATOR SIZED FOR SMOOTH OPERATION UNDER ALL FLOW CONDITIONS. 16 50 THREE-WAY CHILLED WATER VALVE: POWERS VF 591 WM 125 PSIG VALVE BODY AND ACTUATOR, 8-13 PSIG SPRING RANGE; SEE PLANS FOR SIZES (1/2-INCH THRU 2-INCH SCREWED, 2-1/2 INCH AND LARGER FLANGED). OPERATOR SIZED FOR SMOOTH OPERATION UNDER ALL FLOW CONDITIONS. GALVANIZED STEEL CASING WITH ALUMINUM OR STAINLESS STELL PROBES WITH ALL THREADS, MOUNTING HARDWARE, GASKETS,AND 17 SUPPORT BRACKETS ETC., FOR A COMPLETE INSTALLATION. UNITS SHALL BE SELECTED FOR THE ACTUAL AIR FLOW AND DUCT SIZE STEAM VALVE: HONEYWELL NORMALLY CLOSED SERIES 9100 125 PSIG VALVE BODY AND PNEUMATIC OPERATOR ASSEMBLY, (SPRING RANGES PER DWG. AND SHALL BE AIR MONITOR VOLU-PROBE/VS, (NO SUBSTITUTIONS). (102758/C2), STAINLESS STEEL TRIM, SEE PLANS FOR VALVE BODY SIZED (3/4-INCH - 2-INCH SCREWED BODY AND 2-1/2 INCH - 6-INCH FLANGED BODY), EQUAL PERCENTAGE FLOW, OPERATOR CAPACITY FOR CLOSE-OFF AT UP TO 50 PSIG SAT. STEAM INLET PRESSURE. 53 18 STEAM VALVE: HONEYWELL, NORMALLY OPEN, SERIES 9100 PSIG VALVE BODY AND PNEUMATIC OPERATOR, STAINLESS STEEL TRIM; SEE PLANS FOR VALVE DIFFERENTIAL PRESSURE GAUGE: 4" WHITE DIAL WITH BLACK FIGURES, POINTER ZERO ADJUSTMENT, DIAPHRAGM TYPE WITH MAGNETIC MOVEMENT, 2% FULL SCALE ACCURACY, SELECT RANGE TO MATCH ASSOCIATED VELOCITY PROBE. UNIT TO BE DWYER SERIES 2000. (NO SUBSTITUTION). BODY SIZES (3/4-INCH - 2-INCH SCREWED BODY AND 2-1/2 INCH - 6-INCH FLANGED BODY), EQUAL PERCENTAGE FLOW, OPERATOR CAPACITY FOR CLOSE-OFF AT UP TO 50 PSIG SAT. STEAM INLET PRESSURE. 54 19 PNEUMATIC RATIO RELAY: 1:1 RELAY, 3-15 PSIG INPUT, 3-15 PSIG OUTPUT, HONEYWELL RP971A. TWO-WAY HOT WATER VALVE: HONEYWELL N.C. 125 PSIG VALVE BODY AND PNEUMATIC OPERATOR, V5011 BODY, MP953C OPERATOR WITH POSITIONER, 9-13 PSI SPRING RANGE, SEE PLANS FOR SIZES (3/4-INCH - 2-INCH SCREWED, 2-1/2 INCH - 6-INCH FLANGED BODY), OPERATOR CAPACITY FOR CLOSE-OFF 55 AT 85 PERCENT OF PUMP HEAD. DIFFERENTIAL PRESSURE TRANDUCER/TRANSMITTER: COMPLETE ASSEMBLY FOR SENSING VARIATION IN WATER DIFFERENTIAL PRESSURE. 85 PERCENT OF PUMP HEAD. 57 22 CONTROL VALVE ASSEMBLY: BUTTERFLY VALVE ASSEMBLY, 125 PSIG CAST IRON, FLANGED CONNECTIONS, AND INCLUDING ACTUATORS AND LINKAGE. ZERO TRIPLE DECK MULTIZONE DAMPER, ALUMINUM AIRFOIL BLADES, KNIFE-TYPE BLADE EDGE SEALS, SINGLE 90 ROTATION ACTUATOR TO CONTROL ALL THREE DECKS SIMULTANEOUSLY, GOVERNAIR OR APPROVED EQUAL. CLOSE-OFF VALVES WITH DOUBLE ACTING HIGH PRESSURE CYLINDERS AND POSITIONERS. STAINLESS STEEL STEM, BRONZE DISC AND SEATS RATED FOR CHILLED WATER DUTY. 70 PSIG AIR REQUIRED. HONEYWELL VALVE WITH DEMCO ACTUATOR. SEE PLANS FOR SIZES. 58 CURRENT SWITCH: 0.15A FIXED TRIP SETPOINT, 0.15 TO 200A OPERATING RANGE, SELF-INDUCED POWER NON-POLARITY SENSITIVE OUTPUT, SPLIT-CORE MOUNTING. 23 VERIS HAWKEYE NO. H600 CONTROL VALVE ASSEMBLY - (ON-OFF SERVICE), BUTTERFLY VALVE ASSEMBLY, CAST IRON, CLASS 125, FLANGED CONNECTIONS; INCLUDES PNEUMATIC ACTUATOR (20 PSIG), LINKAGE, STAINLESS STEEL STEM, SEATS, AND CONVENTIONAL DISC. RATED FOR HOT WATER (200 DEGREES F) SERVICE, INSTALL SOLENOID PILOT VALVE, ASCO SERIES 8316, 3/8-INCH, 3-WAY WITH BRASS BODY AND 120 VAC COIL (IN NEMA 1 ENCLOSURE). FISHER MODEL 59 NOT USED. 60 TEMPERATURE SENSOR: 100 OHM RTD ELEMENT. 30 TO 250 DEG. F. MONITORING RANGE, +/- 1.1 DEG. F. ACCURACY, ZERO AND SPAN CALIBRATION, 7600 WITH TYPE 1052 ACTUATOR. 24 CONTROL VALVE ASSEMBLY: FISHER MODEL YS, 3-WAY VALVE WITH PORTING AS SHOWN ON THE DRAWINGS. CLASS 150 CS R.F. FLANGES, MODEL 657 4-20 mA OUTPUT SIGNAL. FURNISH WITH IMMERSION TEMPERATURE WELL. ACTUATOR WITH POSITIONER; CLASS III SHUTOFF WITH DOUBLE DISK SST SEAT GUIDE PLUG AND TFE V-RING PACKING. 25 RUSKIN CD-50, SEE SPECIFICATION SECTION 13943. SIEMENS NO. 536-767 61 1 BTU METER: BTU METER WITH TWO MATCHED TEMPERATURE SENSORS, 32 TO 200 DEG. F MONITORING RANGE, +/- 0.15 DEG F, 2" STAINLESS STEEL NPT THERMOWELLS, 24 VAC INPUT POWER, SIEMENS P1 COMPATIBLE COMMUNICATIONS, LOCAL DIGITAL DISPLAY, NEMA 13 ENCLOSURE. 26 ONICON SYSTEM-10-P1-OPT1 DAMPER OPERATOR: POWERS PNEUMATIC OPERATOR WITH MOUNTING ASSEMBLY AND LINKAGE 3-13 PSIG SPRING RANGE, PM 331 WITH POSITIONER, FURNISH MOTORIZED DISCHARGE DAMPER, SAME SIZE AS DUCT, "RUSKIN" MPDEL CDR 92, WITH NEOPRENE BLADE SEALS, FLANGED, AXLE SHAFT SEALS. 62 FLOW TRANSMITTER: ELECTROMAGNETIC INSERTION TYPE, 4-20 mA OUTPUT, +/- 1% OF READING ACCURACY FOR 2 TO 20 FT/S. +/- 0.02 FT/S BELOW 2 FT/S. 316 STAINLESS STEEL WETTED METAL COMPONENTS. WEATHERTIGHT ELECTRICAL ENCLOSURE. 24 VAC SUPPLY VOLTAGE. ONICON INCORPORATED NO. F-3500 27 NOT USED. 63 NOT USED. HSM 09-04 28 B 10/08 HSM CONSTRUCTION EEA A 12/94 REVISE CONTROLS SEC 209949 D 9/18 B064 LAB MODS SDB AJB 218935 E 7/20 810 GENERATOR SDB RTC 88153 64 NOT USED 65 CONTROL VALVE: VALVE AND ACTUATOR TO BE FACTORY ASSEMBLED. ASSEMBLY PROD. NO. 274-03150 EEA TW-0173 NOT USED. 1491-89-A6 VALVE: THREE-WAY, BRONZE BODY, STAINLESS STEEL TRIM, NORMAL DUTY PACKING, EPDM O-RING, DIRECT COUPLED UNIVERSAL BONNET GLOBE VALVE. FEMALE NPT CONNECTIONS. 29 SIEMENS FLOWRITE VF 599 SERIES - 1-1/4" Cv = 16 QUANTITY OF OPERATORS AS NECESSARY FOR EACH DAMPER SIZE TO ASSURE FULL, SMOOTH, DAMPER TRAVEL STOP-TO-STOP. ACTUATOR: ELECTRONIC VALVE ACTUATOR, PROPORTIONAL CONTROL, 24 VAC OPERATING, 0-10 VDC CONTROL INPUT, 0-10 VDC CONTROL OUTPUT, SPRING 30 RETURN TO FAIL SAFE, MANUAL NOT USED. 3 OVERRIDE, 4" STROKE. P.O. REV SIEMENS FLOWRITE EA 599 SERIES ORDER NO. SKD62U 31 PRESSURE RELIEF DAMPER: BACKDRAFT DAMPER ASSEMBLY WITH FLANGED MOUNTING ON BOTH INNER AND OUTER SIDES, FOR HORIZONTAL AIR FLOW 66 MOUNTING IN WALLS. BLADES SHALL BE AIR FOIL DESIGN, CONNECTING LINKAGE ON THE UNIT SIDE. ALUMINUM FRAME, ALUMINUM BLADES, AND EACH VALVE: THREE-WAY, BRONZE BODY, STAINLESS STEEL TRIM, NORMAL DUTY PACKING, EPDM O-RING, DIRECT COUPLED UNIVERSAL BONNET GLOBE VALVE. SHALL BE FURNISHED WITH ADJUSTABLE COUNTER WEIGHT. UNITS SHALL BE AIR BALANCE INC. FEMALE NPT CONNECTIONS. STATIC PRESSURE SIGNAL TRANSMITTER: SETRA MODEL C264, 1 PERCENT ACCURACY, SELECT RANGE TO MATCH ASSOC. PRESSURE PROBE.THIS PRESSURE NNSA/SANDIA SITE OFFICE 3 RETURN TO FAIL SAFE, MANUAL OVERRIDE, 4" STROKE. CKD ALBUQUERQUE, NEW MEXICO P.O. CONTROL EQUIPMENT SCHEDULE SIEMENS FLOWRITE EA 599 SERIES ORDER NO. SKD62U 33 DWN SANDIA NATIONAL LABORATORIES ACTUATOR: ELECTRONIC VALVE ACTUATOR, PROPORTIONAL CONTROL, 24 VAC OPERATING, 0-10 VDC CONTROL INPUT, 0-10 VDC CONTROL OUTPUT, SPRING TRANSMITTER SHALL HAVE A 4-20 maDC OUTOUT SIGNAL. DESCRIPTION U.S. DEPARTMENT OF ENERGY CONTROL VALVE: VALVE AND ACTUATOR TO BE FACTORY ASSEMBLED. ASSEMBLY PROD. NO. 274-03151 SIEMENS FLOWRITE VF 599 SERIES - 1-1/2" Cv = 25 32 DATE PROJECT NO. FREEZESTAT: HONEYWELL L480, MANUAL RE-SET, PLUS 20-DEGREES F TO PLUS 120-DEGREES F RANGE, 20 FEET CAPILLARY, WITH CAPILLARY SUPPORT PROJECT NO. CLIPS, OPENS ON DROP TO SET POINT, SET TO OPEN CONTACTS ON DROP TO 35 DEGREES F. 67 DRAWN BY RANGE, LOCAL AND REMOTE ZERO CALIBRATION. INSTALL WITH OPTIONAL LARGE BRACKET BYPASS VALVE ASSEMBLY AND ASSOCIATED ACCESSORIES. THERMOSTAT: PNEUMATIC REVERSE-ACTING WALL THERMOSTAT, HONEYWELL TP970B, TWO-PIPE, 60 TO 90- DEGREE F SCALE RANGE, REPLACEABLE CARTRIDGE VERIS NO. PW2LX04S AND AA16 FILTER, STANDARD LOCKING SET POINT COVER AND FITTINGS, 2 TO10-DEGREE F ADJUSTABLE THROTTLING RANGE. of 34 Center For National Security DIFFERENTIAL PRESSURE TRANSDUCER: 4-20 mA 24 VDC OUTPUT, 2-WIRE, +/- 1.0% FULL SCALE ACCURACY, LOCAL DIGITAL DISPLAY, 0-100 PSI PRESSURE CHECKED BY Arms Control SNL ENGR 35 COOLING THERMOSTAT: HONEYWELL T451B, 8 AMP AT 120V(AC), SPST SWITCHING 56 TO 94 DEGREES F RANGE, 2 DEGREES F FIXED DIFFERENTIAL, 68 NOT USED DISCP: "MAKES" CONTACT ON TEMPERATURE RISE. OLD FILENAME: OFFICIAL USE ONLY FILENAME: 102758C.01 MI6001810.dgn M Bohannan SUB-DISCP: Huston Courtyard I 7500 Jefferson St. NE Albuquerque, NM 87109 (505) 823-1000 I 810 SIZE D+ DATE DRAWING NO MI6001810 APP SEQ. FMOC. " KEYSTONE FIG 212 VALVE WITH FIG 790 OPERATOR (NO SUBSTITUTION). SPRING RANGE; SEE PLANS FOR SIZES (3/4-INCH - 2-INCH SCREWED, 2-1/2 INCH - 6 INCH FLANGED BODY), OPERATOR CAPACITY FOR CLOSE-OFF AT of TWO-WAY WATER VALVE: HONEYWELL N.C. 125 PSIG VALVE BODY AND PNEUMATIC OPERATOR, V5011 BODY, MP953C OPERATOR WITH POSITIONER, 9-13 PSI expressed authorization RACK AND PINION TYPE OPERATOR, NEMA 4 4-WAY SOLENOID VALVE, NEMA 4 LIMIT SWITCH WITH TWO ADJUSTABLE SPDT SWITCHES. 21 al l ow ed w ithout the CONTROL VALVE: BUTTERFLY VALVE WITH CAST IRON BODY, ALUMINUM BRONZE DISC, STAINLESS STEM, EPDM SEAT, AND DIRECT MOUNTED PNEUMATIC al teration 56 No DISCS, AND ASCO MODEL 8210 OR EQUAL. Sandia NationalLaboratories Facil ities Managem ent and Operation SOLENOID VALVE: 1-1/2 INCH N.C. BRASS BODY, CLASS B 120 VAC COIL CONTINUOUS DUTY. RATED FOR 200 DEGREE F SERVICE BUNA "N" SEALS AND " Property 20 Center ( FMOC) . RANGE = 0 TO 50 PSID. OUTPUT = 4 TO 20 MA. SETRA MODEL C228-1 120V SEQUENCE OF OPERATION BOILER CONTROL KEYED NOTES BTU01 THE BOILER SYSTEM SHALL BE CONTROLLED THROUGH THE FCS SYSTEM. BOILER START/STOP MAY BE OVERRIDDEN VIA A LOCAL HAND/OFF/AUTO SWITCH LOCATED ON THE HEATING WATER BOILER. THE FCS SHALL ROTATE LEAD/LAG STATUS OF BOILERS MONTHLY IN ORDER TO EQUALIZE RUN TIME. THE FCS SHALL MONITOR BOILER STATUS AND SEND AN ALARM 1 BTU01TW01 R IF THERE IS A FAULT WITH ANY BOILER FUNCTION. BOILERS SHALL MODULATE TO MAINTAIN A LEAVING WATER TEMPERATURE OF 180 DEG F. 2 BOILER STAGING SHALL BE CONTROLLED BY THE FCS AS FOLLOWS: - ADD A BOILER IF THE PRIMARY HWS TEMPERATURE FALLS BELOW 175 DEG F FOR 10 MINUTES. EPO RELAY EPO PUSHBUTTON - SUBTRACT A BOILER IF THE PRIMARY HWR TEMPERATURE RISES ABOVE 160 DEG F FOR 10 MINUTES. REFER TO ELECTRICAL PLANS REFER TO ELECTRICAL PLANS 3 BTU01TW02 4 BTU01FW01 5 VFD01 6 THE FCS SYSTEM SHALL MONITOR TEMPERATURE AT THE COMMON PRIMARY HWS HEADER AND GENERATE AN ALARM IF THE TEMPERATURE RISES ABOVE 190 DEG F OR FALLS VFD02 TO 170 DEG F. THE FCS SYSTEM SHALL MONITOR BOILER PERCENT LOAD. BR01EO01 MBC J PRIMARY PUMPS HEATING WATER TEMPERATURE RESET SCHEMATIC EACH BOILER SHALL CONTROL THE START/STOP OF ITS ASSOCIATED PRIMARY HEATING WATER PUMP. THE BOILER SHALL NOT FIRE UNLESS THE ASSOCIATED PUMP IS RUNNING, AS DETECTED BY THE BOILER FLOW SAFETY SWITCH. EACH BOILER SHALL CONTROL PRE- AND POST-CYCLING OF ITS ASSOCIATED CIRCULATION PUMP. SCALE: NONE BLENDING VALVE CONTROL SECONDARY DISTRIBUTION PUMP CONTROL THE HEATING WATER BLENDING VALVES SHALL MODULATE TO MAINTAIN SECONDARY HEATING WATER SUPPLY TEMPERATURE SETPOINT. THIS SETPOINT SHALL BE RESET THE FCS SYSTEM SHALL CONTROL SECONDARY HEATING WATER DISTRIBUTION PUMP START/STOP. PUMP START/STOP MAY ALSO BE OVERRIDDEN VIA A LOCAL BASED ON OUTSIDE AIR TEMPERATURE PER THE HEATING WATER RESET TEMPERATURE SCHEMATIC. HAND/OFF/AUTO SWITCH. THE PUMPS SHALL OPERATE INDEPENDENTLY OF THE BOILERS. THE BLENDING VALVES SHALL FAIL OPEN TO THE BOILER CIRCULATION LOOP, CLOSED TO THE HEATING WATER RETURN BYPASS. THE FCS SHALL MONITOR PUMP STATUS VIA A CURRENT SWITCH. IN THE CASE OF A FAILURE, AN ALARM SHALL BE GENERATED IN THE FCS. BOILER SYSTEM EPO CONTROL WIRING SCALE: NONE THE FCS SHALL MODULATE PUMP VFD SPEED IN ORDER TO MAINTAIN AN ADAPTIVE DIFFERENTIAL PRESSURE SETPOINT, BASED ON MOST OPEN VALVE POSITION, BETWEEN ELECTRIC BOILER CONTROL THE SUPPLY AND RETURN PIPING. IF THE LEAD PUMP REACHES 100% SPEED FOR GREATER THAN 5 MINUTES, THE LAG PUMP SHALL BE STARTED AND BOTH PUMPS B THE FCS SHALL OPERATE THE ELECTRIC BOILER IF THERE IS A LOSS OF GAS TO THE BUILDING THUS CAUSING ALL GAS BOILERS TO GO INTO ALARM. THE FCS SHALL MONITOR THE ALARM STATUS OF THE BOILER AND INITIATE AN ALARM IF AN ALARM CONDITION IS DETECTED. THE FCS SHALL ALSO OPERATE THE BOILER PERIODICALLY BASED ON THE RECOMMENDATIONS OF THE BOILER MANUFACTURER. BR01ST01 CONTROLLED TOGETHER TO MEET LOOP DP SETPOINT. ON DECREASING LOAD, IF THE TWO PUMPS FALL BELOW 40% SPEED FOR GREATER THAN 5 MINUTES, THE LAG PUMP MBC SHALL BE STOPPED. THE FCS SYTEM SHALL ROTATE LEAD/LAG POSITION MONTHLY TO EQUALIZE RUN TIME. IF THE LOOP DIFFERENTIAL PRESSURE FALLS 2 PSIG BELOW TO BLDG. 810 J SETPOINT FOR MORE THAN 5 MINUTES, THE FCS SHALL GENERATE AN ALARM. BR01TW01 BR01EV01 MBC TO FID-J, FLN-2 61 MBC J 2 J 5 TW VFD 01 72 NC HWS TW HWS 01 N.O. 229 68 60 TT MBC 01 J N. C. BR01TT01 HWS MBC DISTRIBUTION J PUMPS 72 242 HWR STORAGE TANK B TO BLDG. BOILER 4 61 TW 3 02 HWR TW FW 02 02 60 HWS 4 62 LOAD MS ES IS 01 01 77 BR01TW02 TT HWR HWR MBC 05 NC J POWER VFD 75 76 807 230 6 TW 03 J J BTU BR01SS03 BR01ST02 METER MBC J BOILER 3 MBC 1 J 223 BR01AB03 J TO FID-J, FLN-1 HWR MBC 215 61 HWS BR01FB03 MBC J BOILER HEATING WATER SYSTEM SCALE: NONE BR01SS02 BOILER 2 MBC J 222 BR01AB02 HWR MBC J 214 HWS BR01FB02 MBC HWS J BR01SS01 BOILER 1 MBC G J 221 BR01AB01 HWR MBC J BR01PD01 MBC 213 HWS HSM 09-04 88153 BR01FB01 A 10/22/08 HSM - CONSTRUCTION - REV. 0 B 7/20 810 GENERATOR EEA EEA MBC 218935 J 67 SDB RTC P.O. REV DATE DESCRIPTION DWN CKD APP PROJECT NO. PD 01 U.S. DEPARTMENT OF ENERGY BR01MG01 NNSA/SANDIA SITE OFFICE MBC ALBUQUERQUE, NEW MEXICO J SANDIA NATIONAL LABORATORIES INCOMING 01 GAS METER SET METER TO 0-20 PSI DIFFERENTIAL PRESSURE RANGE. DIFFERENTIAL PRESSURE P.O. HEATING WATER CONTROL DIAGRAM SENSOR TO BE LOCATED NEAR HW CONTROL VALVE IN BUILDING 810. REFER TO MI1002810. PROJECT NO. CUB for 810 M DRAWN BY of MG CHECKED BY HEATING WATER DIFFERENTIAL PRESSURE SENSOR SNL ENGR SCALE: NONE DISCP: OLD FILENAME: FILENAME: MI7001810A.DGN MI7001810A.DGN M Bohannan SUB-DISCP: Huston Courtyard I 7500 Jefferson St. NE Albuquerque, NM 87109 (505) 823-1000 I 810A SIZE D+ DATE DRAWING NO MI7001810A 02/13/2008 SEQ. SEQ. FMOC. " J of J expressed authorization J al l ow ed w ithout the J al teration J HWS FID No ST 04 FID Center ( FMOC) . SS 04 FID Sandia NationalLaboratories Facil ities Managem ent and Operation CU 01 FID " Property SP 01 FID HWR AB 04 FID HWR SS 05 FID GENERAL NOTES 1. SEQUENCE OF OPERATIONS THE CONTRACTOR SHALL PROVIDE AND INSTALL ALL CONTROL DEVICES, CONDUIT, WIRE, ECT. FOR A COMPLETE AND OPERATIONAL SYSTEM ACCORDING TO THE PROJECT DRAWINGS AND SPECIFICATIONS. GENERATOR MONITORING THE FCS SHALL MONITOR THE ALARM POINTS AND POWER OUTPUT FROM THE GENERATOR. IF AN ALARM CONDITION IS DETECTED, THE FCS SHALL INITIATE AN ALARM. GENERATOR BREAKER SWITCHGEAR PANEL CU 01 IF CHILLED WATER IS REQUIRED BY THE BUILDING SYSTEMS AND THE FREE COOLING SYSTEM CONDITION REQUIREMENTS ARE MET THEN THE FOLLOWING CHILLED WATER SYSTEM EQUIPMENT SHALL BE STARTED. 1. 2. 3. 4. 5. LEAD HEAT EXCHANGER PUMP 316 OR 317 (ONLY ONE SHALL OPERATE). LEAD TOWER WATER PUMP 313 OR 314 (ONLY ONE SHALL OPERATE). SECONDARY CHILLED WATER PUMP 310. LEAD COOLING TOWER 303 OR 304 (ONLY ONE SHALL OPERATE). LEAD PROCESS CHILLED WATER PUMP 311 OR 312 (ONLY ONE SHALL OPERATE). AA 01 AA 02 MAI NTENANCE SWI TCH STATUS BREAKER POSI TI ON GENERATOR STATUS GENERATOR LOW FUELALARM BASEMENT FAN 111 & EXHAUST FAN 66. AHU-4 OR AHU-5 (ONLY 1 SHOULD OPERATE UNDER GENERATOR POWER). AHU-1 (OPERATE AT A MAXIMUM OF 60% OF FULL FAN SPEED). AHU-2 (OPERATE AT A MAXIMUM OF 60% OF FULL FAN SPEED). AHU-3 (OPERATE AT A MAXIMUM OF 60% OF FULL FAN SPEED). AHU-21 (OPERATE AT A MAXIMUM OF 50% OF FULL FAN SPEED). GENERATOR LOW BATTERY 1. 2. 3. 4. 5. 6. GENERATOR POWER THE FCS SHALL MONITOR THE STATUS OF THE GENERATOR BREAKER AND THE MAINTENANCE SWITCH. IF THE BREAKER IS ENERGIZED AND THE MAINTENANCE SWITCH IS NOT ON, THE FCS SHALL RESTART THE FOLLOWING BUILDING MECHANICAL SYSTEMS IN THE FOLLOWING ORDER ONCE POWER IS RESTORED TO THE FID PANELS. THE FCS SHALL BE PROGRAMMED WITH A MINIMUM OF A 10 SECOND DELAY BETWEEN THE STARTING OF MAJOR MECHANICAL OR LONGER IF REQUIRED BASED THE EXISTING START UP SEQUENCE OF THE EQUIPMENT. GENERATOR CRI TI CALALARM GENERATOR POWER RESTART CONTROL AA 03 ST 01 ST 02 ST 03 FID FID FID FID FID FID FID J J J J J J J FCS GENERATOR CONTROL DIAGRAM SCALE: NONE IF CHILLED WATER IS REQUIRED BY THE BUILDING SYSTEMS AND THE FREE COOLING SYSTEM CONDITION REQUIREMENTS CANNOT BE MET THEN THE FOLLOWING CHILLED WATER SYSTEM EQUIPMENT SHALL BE STARTED. 1. 2. 3. 4. 5. 6. LEAD PRIMARY CHILLED WATER PUMP 305, 306, OR 307 (ONLY ONE SHALL OPERATE). LEAD TOWER WATER PUMP 313 OR 314 (ONLY ONE SHALL OPERATE). LEAD CHILLER 300 OR 301 (ONLY ONE SHALL OPERATE). LEAD SECONDARY CHILLED WATER PUMP 308 OR 309 (ONLY ONE SHALL OPERATE). LEAD COOLING TOWER 303 OR 304 (ONLY ONE SHALL OPERATE). LEAD PROCESS CHILLED WATER PUMP 311 OR 312 (ONLY ONE SHALL OPERATE). IF HOT WATER IS REQUIRED BY THE BUILDING SYSTEMS THEN THE FOLLOWING HOT WATER SYSTEM EQUIPMENT SHALL BE STARTED. 1. 2. LEAD BOILER AND PRIMARY PUMP. LEAD SECONDARY HOT WATER PUMP 229 OR 230 (ONLY ONE SHALL OPERATE). P.O. REV DATE DESCRIPTION DWN CKD PROJECT NO. U.S. DEPARTMENT OF ENERGY NNSA/SANDIA SITE OFFICE ALBUQUERQUE, NEW MEXICO SANDIA NATIONAL LABORATORIES P.O. FCS GENERATOR CONTROL DIAGRAM PROJECT NO. CUB for 810 of DRAWN BY CHECKED BY SNL ENGR DISCP: OLD FILENAME: FILENAME: MI7002810A.dgn M Bohannan SUB-DISCP: Huston Courtyard I 7500 Jefferson St. NE Albuquerque, NM 87109 (505) 823-1000 I 810A SIZE D+ DATE DRAWING NO MI7002810A APP SEQ. FMOC. " of expressed authorization SDB RTC 810 GENERATOR al l ow ed w ithout the 7/20 " Property A 218935 al teration ALL WORK ON THIS DRAWING IS INCLUDED IN PROJECT SCOPE OF WORK No A Sandia NationalLaboratories Facil ities Managem ent and Operation Center ( FMOC) . WHEN THE BUILDING IS OPERATING ON GENERATOR POWER, THE FCS SHALL RESET THE ZONE TEMPERATURE SETPOINTS TO THE UNOCCUPIED VALUES. KEYED NOTES 1 INSTALL NEW BOILER ON NEW EQUIPMENT PAD AT LOCATION SHOWN. 4 MP4001810A 2 M-HSM5004 INSTALL NEW HEATING WATER BUFFER TANK ON NEW EQUIPMENT PAD AT LOCATION SHOWN. ROUTE NEW HEATING WATER LINES TO BOILER(S) AND INTEGRATE INTO THE HEATING WATERSYSTEM AS SHOWN. 5 2 MP4001810A 3 M-HSM5005 MP4001810A M-HSM5001 TIE INTO UNDERGROUND PIPING OUTSIDE THE BUILDING AND ROUTE HEATING WATER SUPPLY AND RETURN LINES AS SHOWN. INSTALL ISOLATION VALVES IN VERTICAL RISERS 4'-0" AFF. FIRE 4 FIRE PANEL RISER INSTALL NEW HEATING WATER PUMPS ON A NEW INERTIA BASES. 1 8" 6" HWS MP4001810A M-HSM5001 HWR 8" BYPASS 6" 5 2 INSTALL NEW IN-LINE HEATING WATER PUMP. 8" BYPASS 9 6 INSTALL NEW EXPANSION TANK AND CONNECT TO THE NEW HEATING WATER PIPING. SUSPEND EXPANSION TANK FROM ROOF STRUCTURE. CONNECT TO MAKE-UP WATER LINE. 221 242 5 10 1 7 NEW CHEMICAL SHOT FEEDER. 213 4 5 222 MP4001810A M-HSM5001 10 1 8 INSTALL NEW UNIT HEATER AT APPROXIMATE LOCATION SHOWN. ROUTE NEW HEATING WATER SUPPLY AND RETURN LINES TO THE UNIT HEATER. 248 9 214 243 6 5 (TYP 3x) B 8" 8" 59 2 64" A 2" A.6 B.2 D C HWR MP4001810A 9 10 5 HWS LEAVE AREA CLEAR FOR FUTURE EQUIPMENT. 9 HWR 11 11 244 VALVE AND BLIND FLANGE FOR FUTURE EQUIPMENT. 223 10 6" HWS/R FUTURE HWS M-HSM5001 INSTALL FUTURE LINES AS SHOWN. PROVIDE VALVES AND BLIND FLANGES. LEAVE AREA CLEAR TO ROUTE LINES IN THE FUTURE. 10 1 8 215 7 INSTALL PIPE SLEEVES FOR PENETRATIONS THROUGH WALL. 9 229 4 HWR 12 6" 3 10 6 10 5 MP4001810A 9 9 M-HSM5001 4 B HWR 13 HWS 3 9 230 4 2 8" B 9 1 59 1 64" IBHI PANEL IBLI BLD 810 KEY PLAN 12 N.T.S. 6" HWS/R TO BLDG 810 3 REFER TO WW8001810 FOR CONTINUATION HSM 09-04 810A CUB HWS/R PIPING PLAN B 3/26/09 A 10/22/08 C 07/20 88153 SCALE:5964 HSM 09-04 88153 218935 HSM - ASI #2 - REV. 1 EEA HSM - CONSTRUCTION - REV. 0 EEA EEA KMQ RTC 810 BACKUP GENERATOR P.O. REV DATE DESCRIPTION DWN CKD APP PROJECT NO. U.S. DEPARTMENT OF ENERGY NNSA/SANDIA SITE OFFICE ALBUQUERQUE, NEW MEXICO SANDIA NATIONAL LABORATORIES P.O. ENLARGED HEATING WATER PIPING PLAN PROJECT NO. CUB for 810 of DRAWN BY CHECKED BY SNL ENGR DISCP: 0 1' 2' 4' 6' OLD FILENAME: M SUB-DISCP: P 810A SIZE MP4001810A.DGN DATE DRAWING NO This drawing is intended to be printed at the "D" size. The scale noted and represented is only valid at that size and scaled dimensions at sizes other than "D" are representative only. FILENAME: MP4001810A.DGN A Joint Venture D+ MP4001810A.DGN 02/13/2008 SEQ. FMOC. " 245 of HWS HWR 10 expressed authorization 7 8 " Property 8" al l ow ed w ithout the 10 al teration 59 1 64" No 10 Sandia NationalLaboratories Facil ities Managem ent and Operation Center ( FMOC) . 13 HWR TIE NEW HWS/R INTO EXISTING 8" HEADER PIPES. HWS 13 8" HWR HWR AHU1 HWR 237 239 HWS 233 HWR 238 AHU2 HWS HWR HWR AHU3 231 2" 232 HWS 3" 2" 3" 3" HWR 240 AHU4 HWR HWS 234 2-1/2" 3" HWR 343 2 HWR HWR AHU5 T 241 HWR 1 342 HWS 1 235 HWS 3 B 1 2 " 2 HWS 3" 4" 2-1/2" 223 HWR 215 HWS HWS TO EXISTING CONNECT TO 243 NPW MAKEUP HWR 236 214 HWS 810 EXP 248 TANK UH °F 8" HWS HWR 2" °F CUB VFD NC 1 2 " 2 HWS 8" 221 229 230 CAPPED FOR FUTURE 8" HWR HWR HEATING 213 HWS HWS WATER NO °F STORAGE PSI 8" NO 8" 242 6" VFD TANK HWS NO °F NO °F PSI VFD HWR HWR NC 8" 8" CAPPED FOR FUTURE HSM 09-04 1 12" SHOT 88153 8" FEEDER 218935 A 10/22/08 HSM - CONSTRUCTION - REV. 0 B 07/20 810 GENERATOR REV DATE DESCRIPTION DWN 12" TYP NNSA/SANDIA SITE OFFICE ALBUQUERQUE, NEW MEXICO NEW CHEMICAL SHOT FEEDER. REFER SANDIA NATIONAL LABORATORIES TO SNL STANDARD DETAIL MP5013. P.O. B INSTALL NEW INLINE CIRCULATOR PUMP. PROJECT NO. XX 3 INSTALL NEW ELECTRIC BOILER. SEE DETAIL DRAWN BY Center For National Security . CHECKED BY Arms Control XXXXX 4 INSTALL PIPE WELL FOR NEW TEMP SENSOR 77. SNL ENGR XXXXX DISCP: OLD FILENAME: FILENAME: M SUB-DISCP: SIZE MP7009810.DGN MP7009810.dgn 810 P A Joint Venture D+ DATE DRAWING NO 07/28/2005 SEQ. MP7009810.DGN APP of MP7009810 HEATING WATER PIPING DIAGRAM 2 CKD U.S. DEPARTMENT OF ENERGY 1 CONNECT NEW HWS/R TO EXISTING 8" HEADERS. KMQ RTC PROJECT NO. M-HSM5002 1 EEA P.O. 3 KEYED NOTES EEA FMOC. " 222 of °F °F 1 1 " 2 1 22" expressed authorization PSI PSI 2-1/2" al l ow ed w ithout the 6" al teration 6" " Property 8" No HWR Sandia NationalLaboratories Facil ities Managem ent and Operation Center ( FMOC) . 810 HW PIPING OFFICIAL USE ONLY ELECTRICAL STANDARD SYMBOLS DESCRIPTION SYMBOL DESCRIPTION N CONTROLS EQUIPMENT SUFFIX EXPLANATIONS. SEE NOTE 11 FOR MARKING. = SWITCH IDENTIFICATION. SEE STANDARD CONSTRUCTION SPECIFICATION 265100 FOR WHEN ATTACHED TO ANOTHER SYMBOL, INDICATES SURFACE MOUNTING. PROVIDE FLUSH-OR ADDITIONAL INFORMATION. SURFACE-MOUNTED JUNCTION BOXES AND CONDUCTORS AS REQUIRED BY N LUMINAIRE, DOWNLIGHT, SURFACE-MOUNTED N = EQUIPMENT SCHEDULE ENTRY, WHICH a N SUFFIX EXPLANATIONS. SEE NOTE 11 FOR MARKING. TR TRANSFORMER; SIZE, TYPE, AND NOMENCLATURE AS SHOWN IN THE EQUIPMENT SCHEDULE. PC PHOTOCELL, SEPARATELY MOUNTED. WHEN INTEGRAL TO THE EQUIPMENT BEING CONTROLLED, N N 265100 FOR ADDITIONAL INFORMATION. EXPLANATIONS, AND NOTE 11 FOR MARKING. N PLUG STRIP, SURFACE-MOUNTED WITH SNAP SWITCH, OVERLOAD PROTECTION, AND NEMA AND TRIM PROVISIONS. a = SWITCH IDENTIFICATION. J JUNCTION BOX M VIDEO MONITOR, AS SHOWN IN KEYED NOTES. INV LUMINAIRE, FLUORESCENT, NOMINAL 1X4 N = EQUIPMENT SCHEDULE ENTRY, WHICH SHALL 5-15R RECEPTACLES. N = EQUIPMENT SCHEDULE ENTRY WITH SPECIFIC MANUFACTURER'S NORMAL POWER AND CONTROLS, 120V TO 4160V, EXCEPT EMCS PURPLE ENERGY MANAGEMENT CONTROL SYSTEM (EMCS) ORANGE SPECIAL POWER (DC, ISOLATED, EMERGENCY, REGULATED, USER) BLACK SPECIAL NON-POWER (CLOSED-CIRCUIT TV, INTERLOCKS, USER) GREEN GROUND, WHEN RUN SEPARATELY FROM POWER CONDUCTORS BROWN FIRE AND EVACUATION ALARMS YELLOW INTRUSION ALARM AND ACCESS CONTROL DOUBLE-FACES AND BI-DIRECTIONAL ARROWS, UNIVERSAL MOUNTING, UNIVERSAL 120/277 VOLTAGE SHALL HAVE INTEGRAL ELECTRONIC SELF-TEST AND DIAGNOSTIC CIRCUIT WITH INDICATOR LED AND MANUAL TEST BUTTON ON LOWER EDGE OF BODY. EMERGENCY LIGHTS SHALL HAVE HIGH-IMPACT PLASTIC BODY WITH TWO INDIVIDUALLY-AIMED LAMPS, UNIVERSAL MOUNTING, UNIVERSAL 120/277 VOLTAGE OPERATION, AND REPLACEABLE SEALED BATTERY. UNIT SHALL HAVE INTEGRAL ELECTRONIC SELF-TEST AND DIAGNOSTIC CIRCUIT WITH INDICATOR LED AND MANUAL TEST BUTTON ON LOWER EDGE OF BODY. PROVIDE EXIT AND EMERGENCY FIXTURES AS FOLLOWS, UNLESS OTHERWISE SHOWN ON THE DRAWINGS: LIGHTING INVERTER, WITH POWER CONNECTIONS AS SHOWN ON DRAWINGS. INVERTER TO BE FURNISHED AS SFE. INCLUDE VOLTAGE, NUMBER AND TYPE OF LAMPS AND BALLAST, AND MOUNTING PROVISIONS. a DATA. SEE NOTE 11 FOR MARKING. TYPE MANUFACTURER & MODEL BATTERY SERVICE RADIATION DETECTOR STATION, WITH DATA DROP AND POWER RECEPTACLE AS SHOWN ON EXIT LIGHT DUAL-LITE LXUGB NO INVERTER CIRCUIT DRAWINGS. DETECTOR TO BE FURNISHED AS SFE. DETECTOR TYPE TO BE IDENTIFIED IN EXIT LIGHT DUAL-LITE LXUGBE-I YES LIGHTING CIRCUIT KEYED NOTES. EMERGENCY LIGHT HIGH-LITES HL-100-SX YES LIGHTING CIRCUIT a = SWITCH IDENTIFICATION. SEE STANDARD CONSTRUCTION SPECIFICATION 265100 FOR RD ADDITIONAL INFORMATION AND FOR TROFFER CABLE WHIP OPTIONS. N JUNCTION BOX, 4" SQUARE GALVANIZED STEEL BOX, STEEL CITY OR EQUIVALENT. SURFACE MOUNT-BLANK GALVANIZED STEEL COVER PLATE WITH CRUSHED OR ROLLED CORNERS LUMINAIRE, FLUORESCENT, NOMINAL 2X4 N = EQUIPMENT SCHEDULE ENTRY, WHICH SHALL FLUSH MOUNT- BLANK HEAVY-DUTY NYLON COVER PLATE, COLOR TO MATCH OTHERS IN ROOM. INCLUDE VOLTAGE, NUMBER AND TYPE OF LAMPS AND BALLAST, AND MOUNTING PROVISIONS. a PULL BOX, SQUARE PAINTED STEEL WITH COVER. N = EQUIPMENT SCHEDULE ENTRY WITH a = SWITCH IDENTIFICATION. SEE STANDARD CONSTRUCTION SPECIFICATION 265100 FOR SPECIFIC MANUFACTURER'S DATA. MOUNT AS SHOWN ON DRAWINGS. N SERVICE OF CONDUCTORS: SHALL INCLUDE VOLTAGE, WATTAGE AND TYPE OF LAMPS AND BALLAST, AND MOUNTING N 10. DRAWINGS. DETECTOR TO BE FURNISHED AS SFE. DETECTOR TYPE TO BE IDENTIFIED IN ASSIGN MULTI-POLE CIRCUITS BY THE PANELBOARD LOCATION NUMBER AS FOLLOWS, UNLESS OTHERWISE SHOWN ON THE DRAWINGS: 2-POLE CIRCUIT: USE THE FIRST PANELBOARD NUMBER 3-POLE CIRCUIT: USE THE MIDDLE PANELBOARD NUMBER 3. PROVISIONS. a = SWITCH IDENTIFICATION. SEE STANDARD CONSTRUCTION SPECIFICATION a = GROUND GAS DETECTOR STATION, WITH DATA DROP AND POWER RECEPTACLE AS SHOWN ON KEYED NOTES. LUMINAIRE, HIGH- OR LOW-BAY, METAL-HALIDE N = EQUIPMENT SCHEDULE ENTRY, WHICH = SWITCHED GD ADDITIONAL INFORMATION AND FOR TROFFER CABLE WHIP OPTIONS. CONDUIT OR RACEWAY, EXPOSED OR SURFACE-MOUNTED. SYMBOLS INDICATE NUMBER AND = NEUTRAL S VOLTAGE, NUMBER AND TYPE OF LAMPS, BALLAST OR TRANSFORMER TYPE AS APPROPRIATE, a SEE NOTE 4 FOR MOUNTING INSTRUCTIONS, NOTE 5 FOR EQUIVALENT PRODUCTS AND SUFFIX BLUE EXIT LIGHTS SHALL HAVE BLACK HIGH-IMPACT PLASTIC BODY WITH CONFIGURABLE SINGLE- OR THE PC LETTERS SHALL APPEAR WITHIN THE SYMBOL FOR THE CONTROLLED EQUIPMENT. AUDIO SPEAKER, PUBLIC ADDRESS OR AS SHOWN IN KEYED NOTES. LUMINAIRE, TRACKLIGHT N = EQUIPMENT SCHEDULE ENTRY, WHICH SHALL INCLUDE SNAP SWITCH, N = POLE TYPE, X = STYLE, a = DEVICE OR CIRCUIT BEING SWITCHED. SANDIA RESTRICTED NETWORK, INTERCOM,TELEPHONE,INSTRUMENTATION OPERATION, GREEN LETTERING AND ARROWS, AND INDIRECT-VIEW LED LAMP SYSTEM. BATTERY MODEL PROVISIONS. a = SWITCH IDENTIFICATION. SEE STANDARD CONSTRUCTION SPECIFICATION a WHITE LUMINAIRES AND LIGHTING CONTACTOR ENCLOSURES SERVED BY EMERGENCY POWER CIRCUITS. WHICH SHALL INCLUDE VOLTAGE, NUMBER AND TYPE OF LAMPS AND BALLAST, AND TRIM INSTRUCTIONS. SEE NOTE 11 FOR MARKING. SANDIA CLASSIFIED NETWORK 9. INSTALL "EMERGENCY SERVICE" LABEL (THOMAS & BETTS WAT-5033 OR EQUIV.), COLOR: BLACK ON ORANGE (NORMALLY ON) OR BLACK ON YELLOW (NORMALLY OFF),VISIBLE FROM THE FLOOR, ON ALL 265100 FOR ADDITIONAL INFORMATION. LUMINAIRE, SCONCE OR DECORATIVE, WALL-MOUNTED N = EQUIPMENT SCHEDULE ENTRY, SPECIAL RECEPTACLE, N = NEMA CONFIGURATION NUMBER. SEE NOTE 4 FOR MOUNTING WHITE/RED STRIPED SCHEDULES. SHALL INCLUDE VOLTAGE, NUMBER AND TYPE OF LAMPS AND BALLAST, AND TRIM SEE NOTE 4 FOR MOUNTING INSTRUCTIONS AND NOTE 5 FOR EQUIVALENT PRODUCTS AND = PHASE KEYED NOTES THE EQUIPMENT AND KEYED NOTES, DRAWING DETAILS, OR EQUIPMENT DOUBLE DUPLEX RECEPTACLE, TWO 125V, 20A, NEMA 5-20R RECEPTACLES IN THE SAME BOX. N ELECTRICAL EQUIPMENT N PROVISIONS. a = SWITCH IDENTIFICATION. SEE STANDARD CONSTRUCTION SPECIFICATION J N INCLUDE VOLTAGE, NUMBER AND TYPE OF LAMPS AND BALLAST, AND TRIM PROVISIONS. a SUFFIX EXPLANATIONS. SEE NOTE 11 FOR MARKING. J MECHANICAL EQUIPMENT LUMINAIRE, DOWNLIGHT, FLUSH-MOUNTED N = EQUIPMENT SCHEDULE ENTRY, WHICH SHALL SEE NOTE 4 FOR MOUNTING INSTRUCTIONS AND NOTE 5 FOR EQUIVALENT PRODUCTS AND N N SEE NOTE 4 FOR MOUNTING INSTRUCTIONS AND NOTE 5 FOR EQUIVALENT PRODUCTS AND a CONDUITS AND RACEWAYS SHALL BE COLOR -CODED BY MEANS OF 3/4" TAPE (SCOTCH #35 OR EQUIVALENT) APPLIED AT EACH JOINT AND TERMINATION AS FOLLOWS: SIMPLEX RECEPTACLE, 125V,20A,NEMA 5-20R DUPLEX RECEPTACLE, 125V, 20A, NEMA 5-20R NXa 8. THE FOLLOWING SYMBOLS ARE USED FOR THE APPLICATION SHOWN, WHERE N = EQUIPMENT SCHEDULE ENTRY: STANDARD SYMBOLS (CONTINUED) STANDARD SYMBOLS SYMBOL 2. 265100 FOR ADDITIONAL INFORMATION AND FOR CABLE WHIP OPTIONS. THE FOLLOWING SYMBOL OUTLINE STYLES SHALL BE USED TO INDICATE WHETHER THE ITEM IS TO BE PROVIDED NOTE: SWITCHBOARDS POPULATED WITH ONLY MULTI-POLE CIRCUIT BREAKERS MAY HAVE A SINGLE NEW AND INSTALLED, OR IS EXISTING TO REMAIN, OR IS EXISTING TO BE DEMOLISHED. NUMBER ASSIGNED TO EACH BREAKER POSITION, WHICH SHALL BE USED AS THE CIRCUIT NUMBER. CONDUIT OR RACEWAY, CONCEALED AND ACCESSIBLE BEHIND PANELS OR ABOVE CEILINGS. LUMINAIRE, EXTERIOR N = EQUIPMENT SCHEDULE ENTRY, WHICH SHALL INCLUDE VOLTAGE, PROVIDE NEW AND INSTALL EXISTING TO REMAIN EXISTING TO BE DEMOLISHED 11. WATTAGE AND TYPE OF LAMPS AND BALLAST, AND MOUNTING PROVISIONS. a = SWITCH CONDUIT OR RACEWAY, CONCEALED AND INACCESSIBLE UNDER FLOOR OR SLAB, OR BURIED. IDENTIFICATION, OR a = PC TO INDICATE INTEGRAL PHOTOCELL CONTROL. SEE STANDARD a N CONSTRUCTION SPECIFICATION 265100 FOR ADDITIONAL INFORMATION. EQUIPMENT, USE BROTHER P-TOUCH 3 LABEL MAKER WITH TC-10 LABEL CARTRIDGE. FOR EXTERIOR R N EQUIPMENT, USE ALUMINUM DYMO HALF-INCH TAPE LABEL WITH EMBOSSED LETTERING. ABBREVIATE LETTERING TO PROVIDE NECESSARY INFORMATION WITH MINIMUM LABEL SIZE, SUCH AS: MOTOR X = MOTOR NAMEPLATE HORSEPOWER, N = EQUIPMENT SCHEDULE ENTRY. MOTOR SHALL HAVE FINAL CONNECTION MADE USING FLEXIBLE MEANS. LABEL ALL RECEPTACLE AND SWITCH COVERS WITH PANELBOARD AND CIRCUIT NUMBER. FOR INTERIOR NOTE: WHEN WORK IS COMPLETE, RED-LINE AND AS-BUILT FINAL RECORD DRAWINGS SHALL BE PUBLISHED WITH ALL SYMBOL OUTLINE STYLES CONVERTED TO THE "EXISTING TO REMAIN" OUTLINE STYLE. EMERGENCY LIGHTING CIRCUIT, DIAGONAL GRID INDICATES NORMALLY-ON CIRCUIT AND PANELBOARD 2BL4, CIRCUIT 23 = 2BL4-23 CROSSHATCH GRID INDICATES NORMALLY-OFF CIRCUIT. APPROPRIATE GRID APPLIES TO X N EXCEPTION: FRACTIONAL-HORSEPOWER MOTORS WITH INTEGRAL CORD AND PLUG SHALL BE ENTIRE FIXTURE, OR TO MIDDLE LAMP OF MULTI-LAMP DUAL-BALLAST FIXTURE AS SHOWN. SERVED FROM A CONTROLLED RECEPTACLE MOUNTED AS CLOSE AS PRACTICAL TO THE MOTOR, SEE NOTE 9 FOR EMERGENCY LUMINAIRE MARKING. 12. NOTE: WHEN ALL WORK ON DRAWINGS IS NEW, THE "EXISTING TO REMAIN" OUTLINE STYLE SHALL BE USED. LABEL ALL SWITCHGEAR, PANELBOARDS, AND SEPARATELY-MOUNTED EQUIPMENT WITH FEEDER SOURCE AND CIRCUIT NUMBER. FOR INTERIOR EQUIPMENT, PROVIDE WHITE MICARTA PLATE WITH QUARTER-INCH WHICH SHALL SERVE AS A DISCONNECTING MEANS. DO NOT MODIFY FACTORY CORDS AND BLOCK LETTERING. FOR EXTERIOR EQUIPMENT, PROVIDE ANODIZED ALUMINUM PLATE WITH PLUGS. EXIT LIGHT. MOUNT AS SHOWN ON DRAWINGS. SEE NOTE 9 FOR TABLE OF ACCEPTABLE 4. QUARTER-INCH EMBOSSED BLOCK LETTERING. ATTACH TO EQUIPMENT USING HERMES CONTACT CEMENT IN MOUNT THE LISTED WIRING DEVICES AT THE FOLLOWING HEIGHTS AS MEASURED TO THE CENTER OF THE DEVICE, UNLESS OTHERWISE SHOWN ON THE DRAWINGS: EQUIPMENT AND CONDITIONS OF SERVICE. ALTERNATE EXCEPTION: WHEN SPECIFICALLY SHOWN ON THE DRAWINGS, THE SERVICE A CLEAR SPACE ON THE UPPER PORTION OF THE EQUIPMENT COVER APPROXIMATELY 66" AFF. ABBREVIATE LETTERING OR ADJUST LETTER SIZE TO PROVIDE NECESSARY INFORMATION WITH MINIMUM CONDUCTORS SHALL TERMINATE IN A NEMA L-SERIES TWIST-LOCK RECEPTACLE, AND THE EMERGENCY LIGHT. MOUNT AS SHOWN ON DRAWINGS. SEE NOTE 9 FOR TABLE OF INTEGRAL MOTOR CORD IN A MATING PLUG, WHICH SHALL SERVE AS A DISCONNECTING LABEL SIZE, SUCH AS: DEVICE ACCEPTABLE EQUIPMENT. MEANS. SPECIAL EQUIPMENT, SMALL N = EQUIPMENT TYPE, SEE NOTE 2 FOR EXPLANATION. MOTOR CONTROLLER, SEPARATELY-ENCLOSED N = EQUIPMENT SCHEDULE ENTRY, WHICH LOCATION OR USE 277/480V PANEL BBH14 FROM SWBD 3 CKT 6 RECEPTACLE 18" AFF OFFICES, CONFERENCE ROOMS, SIMILAR SPACES & OUTDOOR LOCATIONS RECEPTACLE 36" AFF CORRIDORS AND HALLWAYS RECEPTACLE 48" AFF LABORATORIES, RESTROOMS, AND MECHANICAL SPACES SPECIAL RECEPTACLE 48"AFF ALL SPACES, UNLESS OTHERWISE SHOWN ON DRAWINGS SNAP SWITCH 48" AFF ALL SPACES, UNLESS OTHERWISE SHOWN ON DRAWINGS DATA DROP 48" AFF ALL SPACES, WHERE CLEAR OF FURNITURE THERMOSTAT 60" AFF ALL SPACES, UNLESS OTHERWISE SHOWN ON DRAWINGS MOTOR CONTROLLER 72" AFF TO TOP ALL SPACES, EXCEPT WHERE MOUNTED ON EQUIPMENT SAFETY SWITCH 72" AFF TO TOP ALL SPACES, EXCEPT 18" AFF MAXIMUM ON ROOFS SYMBOL WITH APPENDAGE IS SURFACE-MOUNTED, OTHERWISE IS FLUSH-MOUNTED. N SHALL SHOW NEMA SIZE, ENCLOSURE TYPE, AND ACCESSORIES. CONTROLLER SHALL HAVE MOUNTING HEIGHT HHW CIRC PUMP 4 WHEN SHOWN INSIDE A LARGER SYMBOL, IS INTEGRAL TO THE LARGER EQUIPMENT. FROM MCC BH3 CKT A3 DISCONNECTING MEANS WITH LOCK-OUT PROVISIONS, MOTOR SHORT-CIRCUIT AND GROUND-FAULT PROTECTION DEVICE, MOTOR STARTER WITH RESETTABLE OVERLOADS, AND SPECIAL EQUIPMENT, MEDIUM N = EQUIPMENT TYPE, SEE NOTE 2 FOR EXPLANATION. ALL ACCESSORIES AND AUXILIARY CONTACTS AS SPECIFIED IN THE EQUIPMENT SCHEDULE. MC N ON ALL SWITCHGEAR, PANELBOARDS AND SEPARATELY-MOUNTED EQUIPMENT, INSTALL SFE ARC FLASH SYMBOL WITH APPENDAGE IS SURFACE-MOUNTED, OTHERWISE IS FLUSH-MOUNTED. SEE NOTE 4 FOR MOUNTING INSTRUCTIONS, NOTE 12 FOR MARKING, AND NOTE 13 FOR 13. N AND SHOCK WARNING LABEL IN A CLEAR SPACE ON THE COVER SO THAT IT IS PLAINLY VISIBLE. ENSURE APPROPRIATE DATA FROM ENGINEER OF RECORD IS LEGIBLY PRINTED PERMANENTLY IN BLOCK LABELING. SPECIAL EQUIPMENT, LARGE N = EQUIPMENT TYPE, SEE NOTE 2 FOR EXPLANATION. EXCEPTION: WHERE SHOWN AS PART OF A ONE-LINE DIAGRAM FOR A MOTOR CONTROL N CENTER, THIS SHALL DESCRIBE A BUCKET OR COMPARTMENT WITHIN THE MOTOR CONTROL EQUIPMENT IS FREE-STANDING AND MOUNTED ON A 4" HOUSEKEEPING PAD UNLESS OTHERWISE SHOWN ON THE DRAWINGS. CENTER. LETTERS. UNLESS SPECIFICALLY SHOWN, DO NOT REPLACE AN EXISTING LABEL WHICH APPEARS SERVICEABLE. EXCEPTION: WHERE SHOWN ON THE DRAWINGS AND EQUIPMENT SCHEDULE, THIS SHALL BE A MOTOR-RATED AND THERMALLY-PROTECTED SNAP SWITCH CONTROLLER FOR FRACTIONAL-HP LIGHTNING PROTECTION AIR TERMINAL, COPPER, SIZE AND MOUNTING PROVISIONS AS MOTORS. SHOWN ON DRAWINGS, SHOWN WITH CROSS-LEAD CONNECTION. SEE ALSO CONSTRUCTION STANDARD SPECIFICATION 264113. PHASE ROTATION CHECK: ON MULTI-PHASE EQUIPMENT, PERFORM A PHASE ROTATION CHECK PRIOR TO 14. ENERGIZING THE EQUIPMENT. USE KNOPP K-3 OR EQUIVALENT DEVICE WITH RED OR "A" LEAD CONNECTED TO PHASE A, WHITE OR "B" LEAD CONNECTED TO PHASE B, AND BLUE OR "C" LEAD 5. PROVIDE WIRING DEVICES ACCORDING TO THE FOLLOWING EQUIVALENCY TABLE: EQUIPMENT GROUNDING CONDUCTOR BOND, WHEN RUN SEPARATELY FROM POWER CONDUCTORS, LISTED AND COMPATIBLE WITH EQUIPMENT BEING GROUNDED, SHOWN WITH GROUND LEAD. CONTACTOR, SEPARATELY-ENCLOSED N = EQUIPMENT SCHEDULE ENTRY, WHICH SHALL SHOW DEVICE SUFFIX ARROW-HART HUBBELL LEVITON PASS-SEYMOUR 1221-I 1221-I 1221-2I 20AC1-I NEMA SIZE AND ENCLOSURE TYPE, COIL VOLTAGE, NUMBER OF NO AND NC CONTACTS AND C SWITCH, SPST THEIR RATINGS, AND ALL ACCESSORIES AND CONTROLS AS SPECIFIED IN THE EQUIPMENT N SCHEDULE. SEE NOTE 4 FOR MOUNTING INSTRUCTIONS, NOTE 12 FOR MARKING, AND NOTE GROUNDING ELECTRODE CONDUCTOR BOND, SHOWS NUMBER AND APPROXIMATE LOCATION OF 13 FOR LABELING. TW SHALL SHOW NEMA ENCLOSURE TYPE, NUMBER OF POLES AND BUSES, AMPERAGE AND/OR 1222-I 1222-I 1222-2I 20AC2-I SWITCH, 3-WAY 3 1223-I 1223-I 1223-2I 20AC3-I SWITCH, 4-WAY 4 1224-I 1224-I 1224-2I 20AC4-I SWITCH, MOTION DET M WATT-STOPPER WS-120/277, OR AS SPECIFIED SWITCH, DIMMING D AS SPECIFIED, COMPATIBLE WITH LAMP BALLAST AND VOLTAGE RESERVED MOTOR HORSEPOWER RATING, AND FUSE PROVISIONS AS APPROPRIATE. SEE NOTE 4 FOR N 2 DRIVEN GROUND RODS BONDED TO GROUNDING SYSTEM. TW LETTERS INDICATE TEST WELL. SAFETY SWITCH, WITH LOCK-OUT PROVISIONS. N = EQUIPMENT SCHEDULE ENTRY, WHICH SS SWITCH, DPST MOUNTING INSTRUCTIONS, NOTE 12 FOR MARKING, AND NOTE 13 FOR LABELING. CABLE TRAY, N = EQUIPMENT SCHEDULE ENTRY. BOND ALL SECTIONS OF TRAY AND SHOW RECEPT., SIMPLEX 5361V 5361-I 5361-I 5361-I RECEPT., DUPLEX 5362V 5362-I 5362-I BR20-I POINT OF CONNECTION TO BUILDING OR SYSTEM GROUND POINT. MOUNT WITH BOTTOM OF N TRAY AT 82" AFF UNLESS OTHERWISE SHOWN. RECEPT., GFCI GF VGF20V GF20IL 7899-I 2095-I RECEPT., ISO GND IG IG5362RN IG-5362 RECEPT., WX-PROOF WP PROVIDE NEMA WEATHERPROOF METALLIC "EXTRA-DUTY" IN-USE COVER BUSWAY, FEEDER TYPE WITHOUT STAB-IN PROVISIONS. N = EQUIPMENT SCHEDULE ENTRY, WHICH SHALL INCLUDE VOLTAGE, AMPERAGE, AND NEMA ENCLOSURE TYPE. MOUNT AS SHOWN 13632-IG IG6300 ON DRAWINGS. SEE NOTE 12 FOR MARKING AND NOTE 13 FOR LABELING. N NAME N BUSWAY, WITH STAB-IN PROVISIONS. N = EQUIPMENT SCHEDULE ENTRY, WHICH SHALL NOTE: PROVIDE EACH DEVICE WITH APPROPRIATE COVER PLATE. GANGED DEVICES SHALL HAVE A SINGLE, COMMON INCLUDE VOLTAGE, AMPERAGE, AND NEMA ENCLOSURE TYPE. NAME = ASSIGNED BUSWAY COVER PLATE. FLUSH-MOUNTED DEVICES SHALL HAVE A PLASTER RING AND HEAVY-DUTY NYLON COVER PLATE, SCHEDULE NAME. MOUNT AS SHOWN ON DRAWINGS. SEE NOTE 12 FOR MARKING AND NOTE COLOR TO MATCH DEVICE. SURFACE-MOUNTED DEVICES SHALL HAVE GALVANIZED STEEL COVER PLATE WITH STEEL 13 FOR LABELING. CITY SMOOTH-ROLLED OR -CRUSHED CORNERS AND EDGES. - EXCEPTION: IN AREAS BEING PARTIALLY REMODELED, MATCH COLOR OF EXISTING DEVICES. SNL 7 11-2011 UPDATED GEN. NOTE 4 NR EB EB B 09/18 UPDATED SPEC REFERENCES MIP TP TP A 04/18 SAND NO. & MASTER SPEC UPDATE MPT MIP MIP 8 2-15 UPDATED RECPT. WX-PROOF NOTE (5) JT EB EB CKD APP SWITCHBOARD OR PANELBOARD, N = EQUIPMENT SCHEDULE ENTRY, WHICH SHALL INCLUDE 6. VOLTAGE, AMPERAGE, CIRCUIT BREAKER POPULATION, DOOR AND COVER ARRANGEMENT, AND PROVIDE ALL RACEWAYS WITH CONDUCTORS ENERGIZED AT MORE THAN 50 VOLTS LINE-TO-GROUND WITH AN NEMA ENCLOSURE TYPE. NAME = ASSIGNED PANEL SCHEDULE NAME.INSTALL WALL-MOUNTED INSULATED COPPER EQUIPMENT GROUNDING CONDUCTOR. THE EQUIPMENT GROUNDING CONDUCTOR SHALL BE SIZED PANELS WITH UPPER EDGE NO HIGHER THAN 78" AFF UNLESS OTHERWISE SHOWN. SEE PER NEC TABLE 250.122, UNLESS OTHERWISE SHOWN. AN EQUIPMENT GROUNDING CONDUCTOR SHALL BE PROVIDED P.O. REV GENERAL NOTES SEE NOTE 12 FOR MARKING AND NOTE 13 FOR LABELING. INSTALL AS-BUILT PANEL SCHEDULE FROM DWN U.S. DEPARTMENT OF ENERGY CURRENT RETURN, UNLESS OTHERWISE SHOWN. ENGINEER OF RECORD. NNSA/SANDIA SITE OFFICE 1. ALBUQUERQUE, NEW MEXICO WHERE SYMBOLS ARE NOT LISTED ON THIS DRAWING, USE THE AMERICAN NATIONAL STANDARD GRAPHIC SYMBOLS FOR ELECTRICAL WIRING AND LAYOUT DIAGRAMS USED IN 7. SANDIA NATIONAL LABORATORIES POWER CONDUCTORS SHALL BE COLOR-CODED AS FOLLOWS: ARCHITECTURE AND BUILDING CONSTRUCTION, ANSI Y32.9-1972. NOT ALL SYMBOLS FLUSH-MOUNTED EQUIPMENT SHALL BE SHOWN SUBMERGED IN THE WALL IN THE PLAN VIEW DRAWINGS. DESCRIPTION BETWEEN SERVICE TRANSFORMERS AND THE BUILDING SERVICE SWITCHGEAR FOR FAULT STANDARD CONSTRUCTION SPECIFICATIONS 262412, 262413 AND 262416 FOR ADDITIONAL INFORMATION. FREE-STANDING EQUIPMENT SHALL BE MOUNTED ON A 4" HOUSEKEEPING PAD. DATE PROJECT NO. VOLTAGE SHOWN ON THESE DOCUMENTS MAY BE USED ON EVERY PROJECT. ADDITIONAL SYMBOLS MAY PHASE A PHASE B PHASE C NEUTRAL GROUND E-0007STD ONE-LINE DIAGRAM SYMBOLS E-0011STD SAMPLE ELECTRICAL EQUIPMENT SCHEDULE SURFACE-MOUNTED EQUIPMENT IN OCCUPIED SPACES SHALL HAVE SKIRTING FROM FLOOR TO FA-7001STD FIRE ALARM WIRING DIAGRAMS CEILING TO CONCEAL CONDUITS. SKIRTING TYPE AND FINISH SHALL COORDINATE WITH T-5002STD ROOM TRIM. TS-0002STD P.O. Electrical Standard Symbol List And General Notes BE FOUND ON THESE RELATED STANDARD DRAWINGS: 120/208Y BLACK RED BLUE WHITE GREEN 277/480Y BROWN ORANGE YELLOW GRAY GREEN WITH PROJECT NO. Standards YELLOW STRIPE TELECOMMUNICATIONS RED AND BLACK OUTLET DETAILS LIGHTING INVERTER OUTPUTS: NORMALLY-ON = ORANGE NOTE: SMALLER GAUGE CONDUCTORS SHALL HAVE COLOR-CODED INSULATION. LARGER CONDUCTORS WHOSE DISCP: E SUB-DISCP: - STD INSULATION IS BLACK SHALL BE COLOR-CODED BY MEANS OF TAPE APPLIED AT EACH END, SPLICE, AND OFFICIAL USE ONLY sjr CHECKED BY nc SNL ENGR nc DATE 04/17/2006 NORMALLY-OFF= PURPLE ELECTRONIC SECURITY SYMBOLS, LEGEND, AND NOTES (OUO) JUNCTION. DRAWN BY OLD FILENAME: FILENAME: SIZE 073740E.02 E-0006STD.DGN A Joint Venture D+ DRAWING NO SEQ. E-0006STD SAND2017- 13251 O FMOC. " CONSTRUCTION STANDARD SPECIFICATION 262923. of MOUNTING INSTRUCTIONS, NOTE 12 FOR MARKING, AND NOTE 13 FOR LABELING. SEE ALSO expressed authorization A DEVICE SHALL NOT BE MOUNTED BELOW A DATA DROP SUCH THAT ACCESS TO THE JACKS IS IMPEDED. ACCESSORIES AND CONTROLS AS SPECIFIED IN THE EQUIPMENT SCHEDULE. SEE NOTE 4 FOR al l ow ed w ithout the ALSO CONSTRUCTION STANDARD SPECIFICATION 264113. al teration MOTOR SHORT-CIRCUIT, OVERLOAD, AND GROUND-FAULT PROTECTION DEVICES, AND ALL ENERGIZE EQUIPMENT UNLESS OBSERVED ROTATION MATCHES THE REQUIREMENTS OF THE EQUIPMENT. THERMOSTATS SHALL BE MOUNTED ABOVE SWITCHES AND RECEPTACLES SHALL BE MOUNTED BELOW SWITCHES, No LIGHTNING PROTECTION EQUIPMENT BOND, SHOWN WITH CROSS-LEAD CONNECTION. SEE Sandia NationalLaboratories Facil ities Managem ent and Operation N CONTROLLER, PROGRAMMING AND STATUS DISPLAY VISIBLE WITH THE COVER IN PLACE, of VFC USED, MANNER CONNECTED, ROTATION OBSERVED, DATE OF TEST, AND NAME OF CRAFTSMAN. DO NOT THE DEVICE MOST OFTEN USED (SWITCH OR RECEPTACLE) SHALL BE MOUNTED AT THE LISTED HEIGHT. " Property SHALL HAVE DISCONNECTING MEANS WITH LOCK-OUT PROVISIONS, BYPASS FULL-SPEED NOTE: WHERE ARCHITECTURAL FEATURES SUCH AS MULLIONS REQUIRE VERTICAL STACKING OF THESE DEVICES, Center ( FMOC) . CONNECTED TO PHASE C. NOTE THE PHASE ROTATION AND ANNOTATE TEST DOCUMENTATION WITH DEVICE MOTOR CONTROLLER, VARIABLE-FREQUENCY N = EQUIPMENT SCHEDULE ENTRY. CONTROLLER - PAG E 5052834477(x4G PS)FO R SN L SU RVEY. GENERAL NOTES 60GPM S. E. E. S. E. E. 0. 75"G 1"G A.T.S S. E. E. 125GPM BACKFLOW D12SDMH37 1. REFER TO EP7001810 FOR ONE-LINE DIAGRAM. PREVENTOR "MS1" "MS2" CP R D S " 18 6 RUNS 4-#500 KCMIL, 1-#4/0 GND., IN 4" C. BUILDING 810 FH810WC D12DI11 1 TO PNL "MS1" 1"G 1.25"STL 1 REFER TO TN1006810 FOR CONTINUATION. 2 REFER TO EP4001810A FOR WORK IN CUB. 3 INSTALL 30KVA DRY-TYPE TRANSFORMER. 4 INSTALL 60A ENCLOSED CIRCUIT BREAKER. 5 INSTALL GPON ONT PER STANDARD DETAILS ON T-5001STD. BEFO RE DIG G IN G O R BACK FILLIN G KEYED NOTES TO PNL "LBB1" 4" W PB S.E.E. 24 "S D S.E.E. RC P 2"CA M C. " N3 I , 6GND. # 1 , 0 / 3 # 1RUN4 PB S. E. E. D12SDCO19 SW-0810-2 4 TF-0810-1 TF-0810-2 TF-0810-3 T 3 C 3" , 0 3/ # 4 N U 1R BLDG SUB PANEL DB M M "CO 4 4-1"C S. E. E. PNL-1BH1 3" STL ENGINE GENERATOR 1" W COP C. " ,2 . D N G 8 2# , 8 8# N RU 1 SWGR SD RCP 24" FRONT 44"COMM DB 3"C . 5 4" S2" C SW-0810-1 YARD HYDR. 2 4 " 6(96-101) PRE-INSULATED 1988 6 WAY 5" ELEC. DUCT 6PR CABLE SD " 4 2 TP P C R P.O. REV DATE DESCRIPTION DWN CKD APP PROJECT NO. U.S. DEPARTMENT OF ENERGY NNSA/SANDIA SITE OFFICE ALBUQUERQUE, NEW MEXICO SANDIA NATIONAL LABORATORIES P.O. ELECTRICAL SITE PLAN BUILDING 810 GENERATOR ELECTRICAL SITE PLAN PROJECT NO. 218935 DRAWN BY V.MONTOYA CHECKED BY W.HERBST SNL ENGR SCALE: 1"=10'-0" DISCP: OLD FILENAME: FILENAME: SKE WE1.1.DGN W Bohannan SUB-DISCP: Huston Courtyard I 7500 Jefferson St. NE Albuquerque, NM 87109 (505) 823-1000 P 810 SIZE D+ DATE DRAWING NO. SKE WE1.1 6/18/2020 SEQ. of P T 8"S-4"C SCALE 1"=10' C FH810SW 10' 0 FMOC. " PLTG2-3-6C CMMH-19A PLTG2-1-2A 4-4" COMM DB NGV810SW-3 5' of 10' expressed authorization CR CR CR CR CR CR C. 1" T-26 " Property 2" CR C. 1" CR CR CR HV810SW C. 1" PB al l ow ed w ithout the PLTG2-2-4B al teration U-6;6 T-101 PB No 810CUB S.E.E. Center ( FMOC) . S.E.E. Sandia NationalLaboratories Facil ities Managem ent and Operation 2" 3" SAS 6" CIP SAS 4" CIP 4" PE GENERAL NOTES 2 1. SEE DRAWING NO. 102720/E1 FOR ELECTRICAL UTILITIES PLAN. B 2. SEE DRAWING NO. 102741/E1-E3 FOR ELECTRICAL EQUIPMENT LIST. 102745/E3 ~ 12" 102745/E3 3. EXACT DIMENSIONS OF ELECTRICAL EQUIPMENT HOUSEKEEPING 21 PADS TO BE COORDINATED WITH THE MANUFACTURER OF THE EQUIPMENT. 4. SEE DRAWING NO. 102735/E1 FOR ELECTRICAL EQUIPMENT A ELEVATIONS AND ELECTRICAL CHARACTERISTICS. 13 8 21 21 8 8 3 12 5' 0" 10' 0" 21 A 26 19 14 5.SEE EP7001810 FOR ELECTRICAL ONE-LINE DIAGRAM. KEYED NOTES C 14 1 102745/E3 42'-0" 102745/E3 PADMOUNTED TRANSFORMER, 1500 KVA, 12470V-480/277V, 3%-4W OIL FILLED 495 GALLONS. 2 RGS TO PVC ADAPTER. 3 TWO 4" RGS CONDUITS WRAPPED. BOTH WITH THREE #4/0 22 3'-6" 3'-6" 3'-6" 3'-6" 3'-6" 3'-6" 3'-6" 2'-0" 3'-0" 12" 2'-0" 3'-0" XXX 3'-0" 3' 6" 3'-6" AWG COPPER, 15KV SHIELDED CABLES. TO FID "X" IN BASEMENT SEE SHEET 102720/E1 FOR CONTINUATION. 3' 6" METERING 4" ALL AROUND INCOMING INCOMING LIVE LIVE USER BLDG. 1500 1500 KVA KVA 4 5 10'-0" 1'-1" 94 4" ALL 95 23 AROUND 4 15KV SWITCHGEAR, 30-4W, 600A, 95KV BIL, NEMA 3R OUTDOOR ENCLOSURE FRONT ACCESSIBLE ONLY. 12" 2 95 480V, 2000 AMP, FUSIBLE BOLTED PRESSURE SWITCH IN NEMA 3R ENCLOSURE. 6 TRENCH FOR OIL AND RAINWATER CONTAINMENT, MIN. DEPTH 1'6". 7 STEEL GRATING OVER ENTIRE TRENCH. 8 3/4" x 10' COPPERCLAD GROUND ROD. 9 #2/0 COPPER CONDUCTOR. CADWELD TO GROUND ROD AND 4 XXX-XX 5 3" 3" 3" COUNTERPOISE. ~ ~ ~ ~ ~ ~ 24 WP,+24" 21 11 #2/0 COPPER CONDUCTOR CADWELD TO GROUND ROD AND 18 8" 15' 0" 21 10 4/0 COPPER COUNTERPOISE BURIED 2'-0" BELOW GRADE. ATTACH TO ENCLOSURE. 12 #2/0 COPPER CONDUCTOR CADWELD TO COUNTERPOISE AND 8 8 36' 0" ATTACH TO ENCLOSURE. 14 1x2 13 #2/0 COPPER CONDUCTOR FROM CONCRETE ENCASED DUCT. CADWELD TO COUNTERPOISE. 20 WP,+24" 14 #2/0 COPPER CONDUCTOR CADWELD TO COUNTERPOISE AND 7 20 21 14 2-WAY, 2 DUCT BANK DETAIL " 8 2' 0" 8 REBAR IN FOOTING. 21 15 6 RUNS, 4 EACH WITH: 4-500 MCM THW AND 1#4/0 THW E GROUND IN 4" CONDUIT. NOT TO SCALE 19 16 4" PVC CONDUIT. 17 5" PVC CONDUIT. 2'-7" 11 11 6' 6" 18 3000 PSI CONCRETE. 6 19 SPARE EMPTY 4" RGS CONDUIT, WRAPPED, CAPPED AND MARKED 3" 25 114 114 1 1 3" 3" 3" 3" WITH WOOD POST. 20 6 RUNS, 5 EACH WITH: 4-#500 COPPER THW AND 1-#4/0 16 2' 0" 3" COPPER THW GROUND IN 4" WRAPPED RGS CONDUIT. 1'-6" 10'-0" 3'-0" 10'-0" 1'-6" 12'-6" 21 CADWELD SUBSTATION COUNTERPOISE TO BUILDING COUNTERPOISE 17 10" 3'-6" 14 22 1" CONTROLS CONDUIT. SEE DRAWING SERIES 102764/CXX. 3" 3' 6" 9 WITH #4/0 COPPER CONDUCTOR. SEE DRAWING NO.102727/E1. 9 23 TWO #10 THW COPPER, ONE #10 THW COPPER GROUND 1x4 24 2" PVC CONDUIT. 26 SEE SKE WE1.1 FOR CONTINUATION. NOT TO SCALE 21 8 NORTH SUBSTATION LAYOUT SCALE: 1/4" = 1'-0" 3'-2" 1'-7" 3" 3" 3" 3" 3" 3" 1'-5" 3" 16 3" 3" 18 17 3" 3" 1' 7" 3" 1' 5" 18 3" 2' 0" 3" 3" 3" 3" 3" 3" 16 18 A 3" 3" 3" 218935 07/20 VLM WDH 810 GENERATOR P.O. REV DATE DESCRIPTION DWN CKD APP PROJECT NO. 3x5 2x2 2x2 U.S. DEPARTMENT OF ENERGY NNSA/SANDIA SITE OFFICE ALBUQUERQUE, NEW MEXICO SANDIA NATIONAL LABORATORIES " NOT TO SCALE A 4-WAY, 5 DUCT BANK DETAIL " NOT TO SCALE B 15-WAY, 4 DUCT BANK DETAIL " C P.O. SUBSTATION AND DUCT BANK DETAILS NOT TO SCALE PROJECT NO. Center For National Security DRAWN BY of 4-WAY, 4 DUCT BANK DETAIL CHECKED BY Arms Control SNL ENGR DISCP: OLD FILENAME: FILENAME: 102745E.03 WP5002810.dgn W Bohannan SUB-DISCP: Huston Courtyard I 7500 Jefferson St. NE Albuquerque, NM 87109 (505) 823-1000 P 810 SIZE D+ DATE DRAWING NO WP5002810 12/07/1994 SEQ. FMOC. " A of D expressed authorization " TYPICAL al l ow ed w ithout the 10 al teration 25 ATTACH GROUND TO THE NEUTRAL BUSHING ON THE TRANSFORMER. 4-WAY, 4 DUCT BANK DETAIL No 8 Center ( FMOC) . 8 IN 3/4" CONDUIT TO CIRCUIT INDICATED. Sandia NationalLaboratories Facil ities Managem ent and Operation 21 " Property 21 GENERAL NOTES 1. PROVIDE NEC REQUIRED WORKING SPACE IN FRONT OF ALL PANELS, STARTERS, AND SAFETY DISCONNECT SWITCHES. 2. FOR HEATING SYSTEM WIRING DIAGRAMS SEE DRAWING NO. E-HSM5001. 3 2 3. PROVIDE NEW AIR TERMINALS AND BOND NEW EQUIPMENT, PIPING, ETC. TO EXISTING LIGHTING IBL1-13 IBL1-15 C C FACP FIRE RISER MC MC MC FIRE PANEL 4.REFER TO EP7001810 FOR POWER ONE-LINE DIAGRAM. KEYED NOTES 13 5 J PANEL 1BH2 2 PROTECTION SYSTEM AS REQUIRED PER SPECIFICATION SECTION 13100, NFPA 780, AND UL 96A. IBL1-9 1 ROOFTOP EXHAUSTER. 2 2 #12 3 3 #12 THHN AND 1 #12 THHN GREEN GROUND IN ½" CONDUIT. 5 221 EP4001810A E-HSM5001 4 3 #8 5 PROVIDE EPO SWITCH, CONTROL POWER, AND RELAY WITH 12 CONTACTS FOR BOILER 1 IBHI-8 2 CONTROL. PROVIDE CONTROL WIRING TO BOILERS FOR EMERGENCY SHUTDOWN. REFER TO CONTROL PLANS FOR CONTROL WIRING TO FID PANEL. 213 IBL1-1 3 IBHI-11 222 IBHI-2 1 4 4 257 6 EVAPORATIVE COOLER ON ROOF. 7 EP4001810A MOUNT TRANSFORMER ABOVE PANEL. 8 UNIT HEATER. IBHI-5 214 E-HSM5001 IBL1-2 1 20 IBHI-14 1 IBL1-16 2 EP4001810A 244 E-HSM5001 223 9 LEAVE AREA CLEAR FOR FUTURE EQUIPMENT. 10 REFER TO SHEET EP7001810. 11 600V, 600A, 3P, HEAVY-DUTY, NON-FUSED SAFETY SWITCH. 12 COMBINATION 3/4 HP STARTER/DISCONNECT SWITCH. 13 REFER TO SKE WE1.1 FOR CONTINUATION. 1 25 260 C VFD 215 TYP. 3 IBL1-3 229 6 VFDS VFD MC 3 12 25 230 11 IBL1-14 2 8 10 5 PANEL IBLI 10 7 9 8 247 IBL1-9 256 7 IBL1-13 6 2 5 4 3 2 1 810A CUB POWER PLAN SCALE:5964 HSM 09-04 88153 HSM 09-04 88153 218935 B 5/28/09 HSM - RFI #9 - REV. 1 EEA EEA A 10/22/08 HSM - CONSTRUCTION - REV. 0 EEA EEA C 7/20 810 GENERATOR VLM WDH P.O. REV DATE DESCRIPTION DWN CKD APP PROJECT NO. U.S. DEPARTMENT OF ENERGY NNSA/SANDIA SITE OFFICE ALBUQUERQUE, NEW MEXICO SANDIA NATIONAL LABORATORIES P.O. ENLARGED ELECTRICAL PLAN BLD 810 KEY PLAN PROJECT NO. CUB for 810 DRAWN BY of N.T.S. CHECKED BY SNL ENGR DISCP: 0 1' 2' 4' This drawing is intended to be printed at the "D" size. The scale OLD FILENAME: EP4001810A.DGN noted and represented is only valid at that size and scaled dimensions at sizes other than "D" are representative only. E SUB-DISCP: P 810A 6' FILENAME: EP4001810A.DGN Bohannan Huston Courtyard I 7500 Jefferson St. NE Albuquerque, NM 87109 (505) 823-1000 SIZE D+ DATE DRAWING NO EP4001810A 02/13/2008 SEQ. FMOC. " 1 IBHI of 2 expressed authorization 245 al l ow ed w ithout the D C al teration B.2 No A.6 Sandia NationalLaboratories Facil ities Managem ent and Operation A 243 Center ( FMOC) . B 262 " Property FI DJ SS C OFFICIAL USE ONLY SPLICE ROOF LEVEL GENERAL NOTES 21 1. SEE DRAWING NO. 1 0274 1/E1 -E3 FOR EQUIPMENT LIST. BOX 2. FOR ELECTRICAL EQUIPMENT LIST, SEE DWG. NO. EP6004810. 225A 225A 225A 57 225A OF 53) 166 6 5 6 6 6 PANEL PANEL PANEL PANEL "P4A" "M4A" "P4B" "P4C" 225A 400A 225A 225A 225A 225A 100A 32 30 KVA 6 19 PANEL PANEL "L4A" "P4S" "P4D" "P4E" 100A 100A 225A 225A 75KVA TF-4PL1 100A 35 PANEL "IDR4" 100A PANEL PANEL PANEL PANEL PANEL "P4F" "P4G" "P4H" "L4B" "P4I" "M4B" 225A 225A 225A 225A 400A 250A INV-EM4B 129 (TYP. OF 13) (TYP. OF 9) INV-EM4A 49 100A 100A 100A 137 (TYP. OF 40) 1 3 #4/0 AWG, 1 5KV, COPPER, SHIELDED CABLE AND #2 GROUND IN 4" CONDUIT. 2 3 #2 AWG, 1 5KV, COPPER, SHIELDED CABLE AND #6 GROUND IN 4" CONDUIT. 3 6 RUNS, EACH WITH: 4-500KCMIL AND 1 #4/0 GROUND IN 4" CONDUIT AND 1 5 75 KVA 7 34 KEYED NOTES 166 6 6 6 PANEL 248 5 18 136 E 225A TRE4 150A 7 225A 7 247 PANEL TRW4 225A 6 6 20 75 KVA 6 225A 225A TR4S 6 75 KVA PANEL 225A PANEL 225A "4PL1" 120/208V (TYP. (TYP. OF 22) 100A TRQ4 4TH FLOOR SPLICE EMPTY 2" C. 4 4 RUNS, EACH WITH 4-#600 KCMIL AND 1 #4/0 GROUND IN 5" C. 5 3#2 AND 1 #8 GROUND IN 1 -•" CONDUIT. 6 PROVIDE AND INSTALL 4 #4/0 AND 1 #4 GROUND IN 212" CONDUIT. 7 4#2 CONDUCTORS, 1#8 GROUND IN 1.5" CONDUIT. 8 4#500 KCMIL AND 1#2 GROUND IN 4" CONDUIT. 9 TO 400 AMP BREAKER IN BLDG LOAD SWITCHGEAR. 10 TO 225 AMP BREAKER IN BLDG LOAD SWITCHGEAR. 11 4# 350KCMIL AND 1 #4 GROUND IN 3" CONDUIT. 12 3#500KCMIL AND 1 #2 GROUND IN 4" CONDUIT. BOX 13 21 225A 225A 225A 225A 225A 225A 225A 225A 225A 225A 225A BUS HAS PROVISIONS FOR FUTURE EXTENSION. 14 3#1/0 AND 1 #6 GROUND IN 2" CONDUIT. 15 2 RUNS OF 4-500KCMIL AND 1 -#1/O GROUND, 4" EMT TO SCIF POWER 225A FILTER CABINET. TR3S 6 6 6 6 6 75 KVA 75 KVA 6 30 KVA 6 6 6 6 6 6 PANEL PANEL PANEL PANEL PANEL PANEL PANEL PANEL PANEL PANEL PANEL PANEL PANEL "P3A" "P3B" "P3C" "L3A" "P3S" "P3D" "P3E" "UPS3" "P3F" "P3G" "P3H" "L3B" "P3I" 225A 225A 225A 100A 100A 225A 225A 100A 225A 225A 225A 250A 225A 5 TRW3 TRE3 100A 5 75 KVA 248 5 7 7 INV-EM3B UPS3 100A 100A 100A INV-EM3A 3% 5W BUSDUCT (TYP) SPLICE BOX 55 (TYP) 3RD FLOOR 225 AMP, 120/208 V, 3% 5W BUSDUCT 225 AMP, 120/208V, (TYP) 48 56 3%, 5W BUSDUCT 56 225A 225A 225A 225A 225A 100A 225A 6 6 225A PANEL PANEL PANEL "P2A" "P2B" "P2C" 225A 225A 225A 247 PANEL "L2A" 100A TRW2 225A 5 7 PANEL PANEL "P2S" "P2D" 100A 225A EXSTNG PANEL "P2E" 225A 35 PANEL "IDR2" 100A PANEL 2084 EXISTING 8.75KW UPS E E PANEL 25 "UPS2" 30 800 AMP, 277/480 V, 100A (TYP) 47 6 6 6 3 POLE, 3 WIRE PLUS GROUND 150A, 22kAIC CIRCUIT BREAKER PLUG-IN UNIT. 20 4#2 & 1 #8 GND CU THHN IN 1 -1/4" EMT, MAXIMUM CIRCUIT LENGTH 10 FT. 21 3#6 & 1 #1 0 GND CU THHN IN 1 " EMT. 22 4#3/0 & 1#6 GND CU THHN IN 2" EMT. 23 4#3/0 & 1#6 GND CU THHN IN EXISTING 3" CONDUIT. 24 4#3/0 & 1 #6 GND CU THHN IN 3" WRAPPED GRC 36" BFG TO TOP. 31 INSTALL PANELBOARD. RECONNECT EXISTING FEEDER AND BRANCH CIRCUITS. "P2F" PANEL PANEL PANEL PANEL 225A "P2G" "P2H" "L2B" "P2I" 225A 225A 250A 225A 32 PROVIDE AND INSTALL 225A, 10kAIC, 120/208V PANELBOARD WITH INTEGRAL SPD. REFER TO PANEL SCHEDULE AND SNL STANDARD SPECIFICATION 16269 AND 16440 FOR ADDITIONAL REQUIREMENTS. 28 29 100A 100A 19 29 INSTALL 3#6, 1#8 GROUND. 225A PANEL 248 UPS2 INV-EM2A PROVIDE AND INSTALL 75KVA TRANSFORMER. 27 4#1 & 1#8 GND CU THHN IN 2" EMT. 225A 6 7 TRE2 100A 5 3% 5W BUSDUCT 6 6 20 75 KVA 75 KVA 18 30 INSTALL 4#1, 1#6 GROUND - 1•" CONDUIT. 30 KVA 6 FOR METERING DETAILS. 26 3#4 & 1#10 GND CU THHN IN 1" EMT. (TYP.) TR2S 6 SEE SHEET 1 02735/E1 28 EXTEND EXISTING CONDUIT AS REQUIRED. INSTALL CONDUCTORS. 225A 6 17 25 4#3/0 & 1#6 GND CU THHN IN 2" EMT. 21 225A BREAKER HAS SINGLE PHASE/PHASE FAILURE PROTECTION. 100A TRQ3 225 AMP, 120/208 V, 16 20 247 40 KW-3? UPS 208Y/120V PANEL 27 27 "2UL2" 256 ROOM 2162/ PANEL 257 2164 "2UL1" 125A ROOM 2085 150A 25 30 33 PROVIDE AND INSTALL 3 POLE, 4 WIRE PLUS GROUND 225A CIRCUIT BREAKER PLUG-IN UNIT. 5 75 KVA 7 100A INV-EM2B 1 34 PROVIDE AND INSTALL 3 #1/0, 1 #6 GROUND IN 1 2" CONDUIT. 100A 84 CIRCUIT 120/208V, 3PH, 10kAIC PANELBOARD PER SNL SPECIFICATION 26 24 16. 36 INSTALL SFE ON CONCRETE PAD. 37 INSTALL 15 kV FEEDER. 3 #4/0 15 kV SHLD. 1 #2 600V GROUND. 38 INSTALL S & C OUTDOOR 15 kV STAND-UP SWITCHGEAR ASSEMBLY. 39 EXISTING SPARE CIRCUIT BREAKER. 40 2 RUNS EACH OF 3-600KCMIL, 1/0 GROUND IN 4 INCH CONDUIT. 41 INSTALL PANEL. TRQ2 2ND FLOOR SPLICE 400 AMP, 277/480V, BOX 35 48 3%, 5W BUSDUCT 26 255 21 225A 225A 225A 225A 225A 225A 225A 225A 225A 225A 33 225A 225A 100A 225A TR1S "P1A" "P1B" "P1C" "L1A" "P1S" "P1D" "P1E" "P1F" "P1G" "P1H" 225A 225A 100A 100A 225A 225A 225A 225A 225A TRW1 UPS TRE1 100A 32 PANEL "L1B" "IDR1" "P1I" 250A 100A 225A 15 BUS DUCT TERMINATION 10 80A PANEL 7 166 126 "RDP" 100A BOX 100A 100A INV-EM1 A 100A "ML1" 8 INV-EM1 B PANEL PANEL "LL1" "PL1" "PL2" 225A 400A 225A 122 400A TRL1 22 200A, ATS 20 "MCC1" 100A PANEL PANEL PANEL PANEL PANEL PANEL PANEL "PBA" "PBB" "LBA" "PBC" "PBS" "LBS" "PBD" 225A 225A 100A 225A 100A 225A 225A METER 225A TRWB 400A 1.0X 5 97 5 7 12 400A 1.0X 248 75 KVA 75 KVA TRQB2 TRQB 249 INV-EMB4 PANEL UPSB "UPSB" "SCIF" 100A PANEL "LBBI" "PBE" 225A 225A "Q" M M M 6 17 MTR (3) 163 E 80E 80E A (NORMAL) NEW FEEDERS TO FEEDER # POWER MANHOLE (STANDBY) #86 1 SWITCHGEAR "MS2" BUILDING POWER 85 85 PANEL PANEL "1BH1" "1BL1" 200A 100A 208Y/120V 39 60A 96 60A 13 2000 PANEL EG 100A 1.0X A CT'S CT'S A V PT'S PT'S V SWITCHGEAR PROCESS POWER "MS1 " BASEMENT 23 GF SUPPLIED WITH UNIT. 12.47KV EG M 36 SWGR A K 1.0X CHILLER. STARTER E G "MS2" 2500 BUILDINGKLPC POWER MAIN SWITCH 12.47KV DIESEL EG 2250KW 36 12470V PRI. 277Y/480V, SEC. 114 38 2500 KLPC "MS1 " PROCESS POWER MAIN SWITCH DISCONNECT PANEL 1BH2 800A PANEL SWGR 100A 480KW BOILER 600A E 41 810 MODIFICATIONS (HSB) JPG JOS 10/12 BLDG 810 CRAY UNIT RELOCATION - AS-BUILT MJL JOS D 11/19 PANEL AND RECEPTACLE INSTALL AS-BUILT EHV SHK E 7/20 810 GENERATOR EHV KAC 155885 B 1/12 160562 C 209629 218935 200A, 480V, 3PH, 4W GF 1500 KVA 251 ATS STANDBY POWER MAIN SWITCH P.O. REV DATE DESCRIPTION DWN CKD PROJECT NO. U.S. DEPARTMENT OF ENERGY TF-081 0-2 NNSA/SANDIA SITE OFFICE ALBUQUERQUE, NEW MEXICO TR1 (3) 163 (3) 163 2 SW-081 0-1 1 200A 1.0X 3 37 FEEDER #3701 400A 1.0X  TIBLI 200 TON 137 D 800A 1.0X 3000A 2000 PHASE RELAY PANEL PT'S 600A 250 MTR 2000 AT 3000A 8 SEC. T.D 225A B 400A 200A 1.0X 1.0X CT'S 13 131 CT'S (3) 163 400A 1.0X 16 "PBF" 600A 400A 1.0X PT'S PANEL 13 13 A 1600A 225A 400A 800A 1.0X 1.0X 1.0X 1.0X LOSS OF 5 INV-EMB3 225A 1.0X 30KVA 1.0X 6 INV-EMB1 400A 1.0X 3000A/ 480V 40 17 60Y 75 KVA BLDG. 810 CUB 60Y 6 6 8 12 "LBB" 121 ~ ~ 6 6 ~ ~ 6 PANEL TRBS ~~ 30KVA INV-EMB2 ~~ 4 225A 247 ~~ ~~ 6 225A 11 11 130 100A 225A 146 1ST FLOOR THRU POWER FILTER 225A 7 PANEL 9 254 22 TRQ1 THRU POWER FILTER 225A TO DIMMING SYSTEM 112.5 KVA PANEL 9 PANEL 225A 120/208V 5 75 KVA 248 5 7 14 1 5 KVA PANEL (3) E 84 15KV SWITCHGEAR 12470V, 3%, 3W, 600AMP, 95KV BIL SANDIA NATIONAL LABORATORIES 3 163 TF-081 0-1 94 12470V 15 KV SWITCH 253 PRI. 3000 AMP, 480V,3%, 4W 277Y/480V, SEC. A SW-081 0-2 3 1500 KVA B BOLTED PRESSURE SWITCH PROJECT NO. 95 Center For National Securit WITH 2500A TYPE KLPC LITTLE HOUSE 114 FEEDER #302 TF-081 0-3 85 SNL ENGR 1 24 252 ONE-LINE POWER RISER DIAGRAM OFFICIAL USE ONLY SCALE: NTS CHECKED BY Arms Control TR3 1 DRAWN BY FUSES AND GROUND FAULT PROTECTION POWER MANHOLE #87 85 P.O. ONE-LINE POWER RISER DIAGRAM TR2 1 247OV DISCP: PRI. E SUB-DISCP: 480Y/277V, SEC. 1 50 KVA OLD FILENAME: FILENAME: 102729E.01 EP7001810.dgn Bohannan Huston Courtyard I 7500 Jefferson St. NE Albuquerque, NM 87109 (505) 823-1000 P 810 SIZE D+ DATE DRAWING NO EP7001810 APP SEQ. FMOC. " PANEL of PANEL PANEL PANEL "PICS" expressed authorization PANEL PANEL ___ al l ow ed w ithout the PANEL 225A 8 14 6 INV-EM1C al teration PANEL 5 6 7 247 PANEL M 33 6 6 No 6 Center ( FMOC) . PANEL 6 6 Sandia NationalLaboratories Facil ities Managem ent and Operation PANEL 6 of PANEL 6 20 75 KVA 75 KVA FREIGHT ELEVATOR W.RECEIVING 30 KVA 6 " Property 6 6 6 SS 6 APP U.S. DEPARTMENT OF ENERGY NNSA/SANDIA SITE OFFICE ALBUQUERQUE, NEW MEXICO SANDIA NATIONAL LABORATORIES P.O. PARTIAL 15KV ONE-LINE DIAGARM 810 GENERATOR PROJECT NO. 218935 DRAWN BY V.MONTOYA CHECKED BY W.HERBST SNL ENGR DISCP: OLD FILENAME: FILENAME: SKE EP7.1.DGN E Bohannan SUB-DISCP: Huston Courtyard I 7500 Jefferson St. NE Albuquerque, NM 87109 (505) 823-1000 P 810 SIZE D+ DATE DRAWING NO SKE EP7.1 7/10/2020 SEQ. of expressed authorization al l ow ed w ithout the CKD al teration DWN No DESCRIPTION FMOC. " Center ( FMOC) . DATE Sandia NationalLaboratories Facil ities Managem ent and Operation REV PROJECT NO. of P.O. SCALE: 1/4" = 1'-0" " Property PARTIAL 15KV ONE-LINE DIAGRAM GENERAL NOTES TELECOMMUNICATIONS STANDARD SYMBOLS DESCRIPTION SYMBOL 1. WHERE SYMBOLS ARE NOT LISTED ON THIS DRAWING, USE THE AMERICAN NATIONAL STANDARD GRAPHIC SYMBOLS FOR TELECOMM AND LAYOUT DIAGRAMS USED IN ARCHITECTURE AND BUILDING CONSTRUCTION. NOT ALL SYMBOLS SHOWN ON THESE DOCUMENTS MAY BE USED ON EVERY PROJECT. DESCRIPTION SYMBOL ONT OUTLET J T-0001STD T-5002STD T-6001STD 24" x 24" x 8" J-BOX VOICE OUTLET TELECOMMUNICATIONS LEGEND AND GENERAL NOTES TELECOMMUNICATIONS RED AND BLACK OUTLET DETAILS COMMUNICATIONS EQUIPMENT SCHEDULES 2. REFER TO SPECIFICATION 270005 F (X) FIBER USER OUTLET FLUSH MOUNT/ GPON (RED & BLACK) (X) FIBER USER OUTLET SURFACE MOUNT (RED & BLACK) F c f (X) COPPER/FIBER USER OUTLET FLUSH MOUNT (RED & BLACK) c f (X) COPPER/FIBER USER OUTLET SURFACE MOUNT (RED & BLACK) 3. ALL BACKBONE PULLBOXES WITH 4" BACKBONE ARE TO BE A MINIMUM SIZE OF 24" x 24" x 8", NEMA 12 ENCLOSURE, CONTINUOUS HINGE WITH HASP AND STAPLE FOR PADLOCKING. 4. ONT MUST BE MOUNTED WITHIN 5' OF A 120V RECEPTACLE. FDU 5. INSTALL ONT TO SUPPORT BRACKET WITH 2 MOUNTING SCREWS. USE APPROPRIATE ANCHORS FOR WALL SUPPORT BRACKET, BRACKET IS TO BE MOUNTED LEVEL. FIBER SHELF FSB 6. USER OUTLET ID STICKERS ARE SFM. FIBER SPLITTER BOX IDENTIFICATION C COPPER USER OUTLET FLUSH MOUNT (BLACK) FDH FIBER DISTRIBUTION HUB IDENTIFICATION C COPPER USER OUTLET SURFACE MOUNT (BLACK) RDT RAPID FIBER DISTRIBUTION TERMINAL IDENTIFICATION 1 KEYED NOTE 7. FIELD VERIFY OUTLET LOCATION WITH CONSTRUCTION OBSERVER PRIOR TO FINAL INSTALLATION. OUTLET MOUNTING HEIGHT TO BE 44 TO 60 INCHES A.F.F. UNLESS OTHERWISE NOTED. 8. INSTALL MEASURED PULL TAPE BETWEEN ALL PULL BOXES AND FROM OUTLET TO FINAL J-BOX. 9. ALL CONDUIT TO BE 3/4" EMT UNLESS NOTED OTHERWISE. FB/R1S0XXX TRUNK FIBER IDENTIFICATION 10.ALL CONDUIT BEND RADIUS TO BE 6 INCHES MINMUM. 1 114 XXXXX EQUIPMENT SCHEDULE SYMBOL BLACK (OR) RED 11.SEE DRAWING T-5001STD FOR USER OUTLET DETAILS. SFM ROOM NUMBER 12.CONDUIT ROUTING IS SHOWN FOR REFERENCE ONLY. CONTRACTOR TO ROUTE CONDUITS AS REQUIRED. SANDIA FURNISHED MATERIALS 13.CONTRACTOR SHALL AS-BUILD DRAWINGS TO INDICATE CORRECT OUTLET LOCATIONS. CONDUIT ROUTING, DEVICES AND ALL NEW COMMUNICATIONS EQUIPMENT. USER OUTLET IDENTIFICATION NO. ACCESS POINT (AP) 14.CONTRACTOR SHALL SEAL & RESTORE FIRE RATING OF ALL PENETRATIONS IN PERMANENT WALL, CEILING, FLOORS PER SNL SPECIFICATION. SPECIFICATION NUMBER 078413 (PENETRATION FIRE STOPPING) SERVED FROM MDR IN BUILDING XXX - FSB - 01 - 880 NUMERICAL IDENTIFICATION FIBER SPLITTER BOX SERVED FROM MDR IN BUILDING 16.EACH PULL BOX IS TO HAVE A PERMANENT LABEL ATTACHED, CENTERED ON THE OUTSIDE OF THE COVER. SEE DETAIL LAMINATED PLASTIC WITH 1/4" HIGH ENGRAVED BLOCK LETTERING. NUMERICAL IDENTIFICATION 1 FIBER DISTRIBUTION HUB 17.CONDUIT SHALL BE LABELED PER SANDIA STANDARD WITH THE FOLLOWING TAPE COLOR: WHITE: BLACK SYSTEM RED CANDY STRIPE: RED SYSTEM CONNECTION PORTS AT FDH NUMERICAL IDENTIFICATION FIBER DISTRIBUTION TERMINAL B/R 01 F1 18.PROVIDE AND INSTALL CONDUIT, OUTLETS, PULLBOXES AND EQUIPMENT AS DETAILED IN DRAWING PACKAGE. PULLBOX LABEL: FLOOR NO. OLT 19.THE EXISTING SINGLE MODE TO DESKTOP RESIDES IN THE FOLLOWING BUILDINGS: 810, 821, 823, 836, 870, 890, 891, 895, 897, 905, 960, 962. (EVERYTHING IN 895 SHALL BE INSTALLED INSIDE THE WALL UNLESS OTHERWISE SPECIFIED) OPTICAL LINE TERMINAL BOX NO. BLACK OR RED 12" x 12" J-BOX FIBER 20.REFERENCE SNL SPECIFICATION 270005 AND T-6001STD FOR TELECOMMUNICATIONS EQUIPMENT SCHEDULE. Center ( FMOC) . J A 6-25-19 REV DATE UPDATES TO TELECOM STD DWGS. JP CH JM DWN CKD APP P.O. DESCRIPTION PROJECT NO. U.S. DEPARTMENT OF ENERGY NNSA/SANDIA SITE OFFICE ALBUQUERQUE, NEW MEXICO SANDIA NATIONAL LABORATORIES P.O. Communications Symbols & General Notes PROJECT NO. Standards DRAWN BY CHECKED BY SNL ENGR DISCP: OLD FILENAME: FILENAME: T-0001STD.DGN T-0001STD.DGN T Bohannan SUB-DISCP: Huston Courtyard I 7500 Jefferson St. NE Albuquerque, NM 87109 (505) 823-1000 - STD SIZE D+ DATE DRAWING NO T-0001STD 05/08/2017 SEQ. FMOC. " F of 3/4" FIRE RATED TELEPHONE BACKBOARD expressed authorization VOICE/OPEN DATA CABINET T-9001 al l ow ed w ithout the RDT - 01 - 1-24 T-9001 al teration POWER POLE, POWER/DATA POLE BUILDING No W.B.E. WALL MOUNTED BUILDING ENCLOSURE Sandia NationalLaboratories Facil ities Managem ent and Operation XXX- FDH - 01 - 880 of ACCESS POINT LABEL IDENTIFICATION NUMBER (SAAW) 15.ALL J-BOX/PULLBOX COVERS ABOVE CEILING TO OPEN DOWNWARD. " Property SAAWXXXXXX BUILDING MATCHLINE - FOR CONTINUATION SEE DRAWING 102724/E2//TN1002810 3 SHOWERS LOCKERS B18A B18B AIRSHAFT #7 AIRSHAFT #8 4 BASEMENT AREAWAY #3 MECHANICAL EQUIPMENT T B01 2 WOMEN B18 6 MIXER TO 1ST FLR IDR T 2 JANITOR B19 5 7 CORRIDOR ƒ" C. B16 B MAINTENANCE OFFICE MEN B17 T B20 J 2 T 3 ELEVATOR EQUIPMENT ROOM 2 B02 CORRIDOR B16 1 EWC SINK ELEVATOR ELEVATOR #1 #2 FIRE CONTROL VALVE ROOM B07A A B A B C C.5 C C.5 C.6 D BASEMENT SIGNAL & TELEPHONE SYSTEM PLAN - EAST SCALE: ‚" = 1'-0" C.6 KEYED NOTES GENERAL NOTES 1. SEE DRAWING NO. 102741/E1-E4 FOR ELECTRICAL EQUIPMENT LIST. 1 2. SEE DRAWING NO. 102729/E3 FOR VOICE AND DATA ONE-LINE. 2 D WEST JUNCTION BOX FOR CONNECTION TO ELEVATOR PHONE. 88153 EXTEND 1" CONDUIT TO TELEPHONE EQUIPMENT ROOM IN BASEMENT. STUB CONDUIT 12" 10/08 HSM CONSTRUCTION REV-0 EEA B 7/20 810 GENERATOR VLM WDH EEA WEST-CENTER ONTO PLYWOOD BACKBOARD AND INSTALL INSULATING BUSHING. 218935 3 A P.O. INSTALL A PULLWIRE IN CONDUIT FOR CONNECTION BY ELEVATOR CONTRACTOR. REV DATE DESCRIPTION DWN CKD PROJECT NO. EAST-CENTER 2-1" EMT CONDUITS WITH PULL STRING, ROUTED TIGHT TO DECK FROM NEW BOILER U.S. DEPARTMENT OF ENERGY CUB PIPE TRENCH TO 1ST FLOOR IDR. NNSA/SANDIA SITE OFFICE B 5 ROUTE 2-1" IT CONDUITS FOR BOILER CUB UP THROUGH CHASE TO 1ST FLOOR. 6 INSTALL 1F SINGLEMODE OSP CABLE IN 1" CONDUIT. 7 ROUTE CONDUIT UP TO FIRST FLOOR IDR. REFER TO TN1005810 FOR CONTINUATION. ALBUQUERQUE, NEW MEXICO SANDIA NATIONAL LABORATORIES EAST P.O. BASEMENT SIGNAL AND TELEPHONE PLAN - EA PROJECT NO. KEYED PLAN DRAWN BY Center For National Security N.T.S. of 4 CHECKED BY Arms Control SNL ENGR 0 2' 4' 8' DISCP:T 12' This drawing is intended to be printed at the "D" size. The scale noted and represented is only valid at that size and scaled OLD FILENAME: 102724E.01 dimensions at sizes other than "D" are representative only. FILENAME: TN1001810.DGN Bohannan 810 SUB-DISCP:N Huston Courtyard I 7500 Jefferson St. NE Albuquerque, NM 87109 (505) 823-1000 SIZE D+ DATE DRAWING NO SEQ. TN1001810 APP FMOC. " PASSENGER of PASSENGER expressed authorization B06 al l ow ed w ithout the FREIGHT ELEVATOR #1 al teration B07 ELEVATOR VESTIBULE No B17A Sandia NationalLaboratories Facil ities Managem ent and Operation B17B EAST STAIR VESTIBULE " Property LOCKERS T SHOWERS Center ( FMOC) . 2 MATCHLINE - FOR CONTINUATION SEE DRAWING 102724/E3 FIE B01-CB 4 1 2-4" CONDUITS. T ELECTRICAL ROOM TELEPHONE ROOM TECH CONTROL B03 B04 T B05 1 5 4. 7 D AIRSHAFT #5 MECHANICAL EQUIPMENT AIRSHAFT #6 MECHANICAL EQUIPMENT B01 4. 3 B01 7 2 3 4 3. 7 5 A B C C.5 D BASEMENT SIGNAL & TELEPHONE SYSTEM PLAN - EAST CENTER SCALE: ‚" = 1'-0" TW-0682 AW-1628 KEYED NOTES GENERAL NOTES TW-0682 WEST AW-1628 SEE DRAWING NO. 102741/E1 - E3 FOR ELECTRICAL EQUIPMENT LIST. 1 TO TELEPHONE EQUIPMENT ROOM. 1" CONDUIT STUBBED 12" BELOW TOP OF HSM 09-04 PLYWOOD BACKBOARD, WITH INSULATING BUSHING. D 88153 2. SEE DRAWING NO. 102729/E3 FOR VOICE AND DATA ONE-LINE DIAGRAM. 2 OCCUPANCY B 2/97 AS-BUILTS PER CONTRACTOR MARKUPS C 10/08 HSM CONSTRUCTION D 7/20 810 GENERATOR 3.SEE DRAWING TN7002810 FOR TELECOM ONE-LINE DRAWING. ƒ" CONDUIT WITH 1-4PR., CAT 5 UTP CABLE TO FIRST FLOOR, P.O. NON - SCIF IDR ROOM. PROJECT NO. REV EAST-CENTER 4 CL DAP EEA EEA WEST-CENTER DUAL RJ-45 OUTLET IN 4/S BOX. 218935 3 12/95 DATE VLM WDH DESCRIPTION DWN CKD U.S. DEPARTMENT OF ENERGY A SECTION OF 4" PCV CONDUIT, 6" MINIMIUM ON BOTH SIDES OF INTERFACE, IS INSTALLED TO PROVIDE ISOLATION INTO THE SCIF ON EACH 4" CONDUIT. NNSA/SANDIA SITE OFFICE ALBUQUERQUE, NEW MEXICO UP TO IDR ON SECOND FLOOR. 5 SANDIA NATIONAL LABORATORIES EAST 2-1" EMT CONDUITS WITH PULL STRING, TIGHT TO DECK FROM NEW BOILER CUB PIPE TRENCH TO 1ST FLOOR IDR. P.O. BASEMENT SIGNAL AND TELEPHONE PLAN - EA 6 STUB OUT 2-1" IT CONDUITS FROM BOILER CUB THROUGH BUILDING EXTERIOR PROJECT NO. WALL INTO PIPE TRENCH. SEAL WALL PENETRATIONS. REFER TO CIVIL PLAN D KEYED PLAN FOR CONTINUATION. 7 DRAWN BY Center For National Security N.T.S. INSTALL 1F SINGLEMODE OSP CABLE IN 1" CONDUIT. CHECKED BY Arms Control SNL ENGR DISCP:T 0 2' 4' 8' 810 SUB-DISCP:N DATE 12' This drawing is intended to be printed at the "D" size. The scale OLD FILENAME: 102724E.02 noted and represented is only valid at that size and scaled dimensions at sizes other than "D" are representative only. FILENAME: TN1002810.DGN Bohannan Huston Courtyard I 7500 Jefferson St. NE Albuquerque, NM 87109 (505) 823-1000 SIZE D+ DRAWING NO SEQ. TN1002810 APP of 1. A FMOC. " of MATCHLINE - FOR CONTINUATION SEE DRAWING 102724/E1//TN1001810 expressed authorization 3 al l ow ed w ithout the B.5 al teration A.8 No A.5 " Property A.2 Sandia NationalLaboratories Facil ities Managem ent and Operation Center ( FMOC) . 3. 3 J MATCHLINE - FOR CONTINUATION SEE DRAWING 102724/E4 25 RC,RF a RC,RF 8 RD RD a RD 12 10 c f a c f 99 a RD RD B046 BC,BF c f a VO T c f RD B107 c f SHIPS LADDER a a VO LIGHT ELECTRIC LAB c f RC, RF VO c f a RD RD 10 R 0-2 OFFICE c f a RD RD AA 35327 c f B 0-2 VO a a VO c f c f VO 14 RD RD RD B 0-5 VO VO VO VO a c fa c f a 234 c f RD a c f VO VO a VO RD OFFICE VO VO OFFICE a OFFICE c f c f RD RD c f c f 13 OFFICE VO 10 10 B076 B055 10 B054 10 a a a c f a a OFFICE C.5 B053 OFFICE B052 B049 RD B077 B079 a a c f 10 OFFICE a VO RD OFFICE B078 VO VO 10 OFFICE 10 ƒ" C. VO VO RD A.5 RD RD RD RD RD B051 RD VO a RD VO B071 B073 VO c f CORR. RD RD VO a c f c f VO CORR. c fa c fa VO VO RD R 0-1 CORR. CORR. a a c f c f B072 c f VO c f a 234 a c f a RD VO 234 VO VO VO VO B074 RD RD 14 13 RD RD B 0-1 234 RD c f VO RD CORR. R 0-5 a a VO VO RD VO VO c f a a RD a B047 VO a a a a RD RD a RC, RF VO c f 10 VO 99 RD RD a c f RD ƒ" C. BC, BF VO UP OFFICE VO RD VO VO RD B048 a c f AIRSHAFT #3 c f OFFICE VO a a 234 B083 RD B084 a c f VO OFFICE OFFICE RD 11 B075 7 234 RD a c f a c f LIGHT ELECTRIC LAB a CABINET "810BAB" BO45 RD VO RC,RF a a B085 c f RC,RF 39179 TO TELEPHONE OFFICE a 10 RECEPTION 1" C. 13 RD VO VO B087 B106 10 c f 10 RC, RF RD a c f a VO RD VO RD RD a VO c f B064 c f 10 c f RD BC, BF OFFICE VO CONFERENCE c f RD VO VO RD T 12 LIGHT ELECTRIC LAB a 11 a VO 10 a B086 a RD a CABINET "810BAB" 13 10 T 1" C. B044 B043 VO RD VO WAITING TO TELEPHONE B063 BC, BF VO 14 OFFICE BC, BF c f LAB OFFICE VO a B105 RC, RF a VO PROGRAM AREA VO RD a 12 T RC, RF RD RD VO c f a a a a c f c f a c f a 6 2-4" C. 4 4" CONDUIT WITH 101 4-1" INNER DUCT 2-4" CONDUITS. DUCT BANK AND MANHOLE 19A TO CONCRETE ENCASED DUCT BANK AND MANHOLE 21 9 2-4" C. J A } } 7 MATCHLINE - FOR CONTINUATION SEE DRAWING 102724/E2 B GENERAL NOTES 6 FIE 7 TELEPHONE BACKBOARD 5 BASEMENT SIGNAL & TELEPHONE SYSTEM PLAN - WEST CENTER SCALE: C C.5 D ‚" = 1'-0" KEYED NOTES 1. SEE DRAWING NO. 102741/E1-E3 FOR ELECTRICAL EQUIPMENT LIST. 1 INDICATES PRE-SET INSERTS, SUPPLIED WITH CELLULAR FLOOR SECTIONS. 12 TW-0682 2-1" CONDUITS. AW-1628 2. FOR COORDINATION OF SPACES ON FLOOR AND CEILING LEVELS IN UTILITY CHASE 2 13 3 3. SEE RESPECTIVE "RECEPTACLE AND UNDERFLOOR POWER PLAN" FOR EQUIPMENT ITEM 5. SEE DRAWING NO. 102745/E1 FOR UNDERFLOOR DUCT SYSTEM DETAILS. TELEPHONE OUTLETS ABANDONED IN PLACE. AW-1628 2-4" CONDUITS UP TO SECURED SIGNAL CABINETS ("Q" SIDE ONLY). SEE DRAWING NO. TW-0682 102729/E4 FOR ADDITIONAL INFORMATION. DESIGNATIONS UNLESS SPECIFICALLY NOTED OTHERWISE. 4. SEE DRAWING NO. 102729/E3 FOR VOICE AND DATA ONE-LINE DIAGRAM. TW-0682 WEST NOT USED. AREA, SEE MECHANICAL DRAWINGS. 14 4 4" CONDUIT STUBBED 3" BELOW CEILING, WITH INSULATING BUSHING. AW-1628 2-3/4" CONDUITS. ENTIRE WALL IS LINED WITH FIRE RETARDANT PLYWOOD (4'X8' SHEETS) PAINTED WITH TWO 15 INSTALL 1F SINGLEMODE OSP CABLE IN 1" CONDUIT. 7. ALL CONDUITS CONCEALED IN FLOOR ARE A MINIMUM 6" BELOW BOTTOM OF LAA DAP B 5/96 USER MODS RCG MG C 2/97 AS-BUILTS PER CONTRACTOR MARKUPS CL DAP D 7/20 810 GENERATOR VLM WDH REV DATE DESCRIPTION DWN CKD PROJECT NO. 16 6 OCCUPANCY P.O. COATS OF WHITE ENAMEL. 6. SEE DRAWING NO. 102729/E4 FOR PDS ONE-LINE DIAGRAM. 12/95 WEST-CENTER D 218935 5 A SEE SKE WE1.1 FOR CONTINUTATION. EAST-CENTER U.S. DEPARTMENT OF ENERGY 2-4" CONDUITS UP TO TELEPHONE CABINETS. SEE DRAWING NO. 102729/E3 FOR ADDITIONAL INFORMATION. NNSA/SANDIA SITE OFFICE ALBUQUERQUE, NEW MEXICO SLAB. 7 8. SEE DRAWING NO. 102720/E1 FOR ELECTRICAL UTILITIES PLAN. 4" CONDUITS STUBBED 12" BELOW TOP OF PLYWOOD BACKBOARD, WITH INSULATING BUSHINGS. SANDIA NATIONAL LABORATORIES EAST 9. ALL CONDUITS ARE ƒ" EMT UNLESS NOTED OTHERWISE. 1-4" CONDUIT UP TO SECURED SIGNAL CABINET (LOBBY/CONFERENCE BUILDING). THE BASE OF THE STRUCTURAL TEES. 9 1-4" CONDUIT UP TO TELEPHONE CABINET (LOBBY/CONFERENCE BUILDING). 10 A MINIMUM OF 18". Center For National Security 1-1" CONDUIT. N.T.S. 12. VOICE/OPEN DATA AND RED DATA OUTLET BOXES ARE SEPARATED BY D PROJECT NO. KEYED PLAN 11. ALL RED DATA SYSTEMS CONDUIT FITTINGS ARE WELDED OR EPOXYED. 11 P.O. BASEMENT SIGNAL AND TELEPHONE PLAN - WE DRAWN BY of 8 10. ALL CONDUIT RUNS AND MIXING BOXES ARE INSTALLED AT, OR NEAR, CHECKED BY Arms Control 2-3" CONDUITS. SNL ENGR DISCP: 3.SEE DRAWING TN7002810 FOR TELECOM ONE-LINE DRAWING. OLD FILENAME: FILENAME: 102724E.03 TN1003810.DGN T Bohannan SUB-DISCP: Huston Courtyard I 7500 Jefferson St. NE Albuquerque, NM 87109 (505) 823-1000 N 810 SIZE D+ DATE DRAWING NO TN1003810 APP SEQ. FMOC. " 8 of D expressed authorization TO CONCRETE ENCASED al l ow ed w ithout the 2-4" C. 4 al teration } DUCT BANK AND BUILDING 807 No 3 Sandia NationalLaboratories Facil ities Managem ent and Operation 15 B.6 Center ( FMOC) . TO CONCRETE ENCASED B.4 " Property 16 5 2 PERSON OFFICE OFFICE VO 1055 R 1-2 1146 1147 RD VO c f a B 1-2 a VO 5 a VO VO a 3 RD a c f c f VO a c f a c f c f COFFEE RD OFFICE 1036 1034 OFFICE OFFICE 4 RD c f RD c f VO RED 1145 3 6 OFFICE 1143 1144 VO OFFICE VO c f c f VO a a c f a 3 VO 1054 1033 VO c f a a c f B 1-1 a c f 3 a c f IDR a 3 9 B 1-4 a c f 3 10 CONFERENCE 11 1049 E 8 VO TELEPHONE BLACK CABINET "810BC1" 30 RD RD VO 1142 RD 1038 1141 VO R 1-3 RD RECEPT. OFFICE VO D.M. RD SECRETARY RD 234 4 BC,BF RD c f VO 1042 CABINET "810Q1" 29 RD RD RD SIGNAL RD 1049 VO VO VO 1053 a c f 3 VO BC, BF CORR. RD OFFICE 1029 BC, BF a CONFERENCE RD 234 234 2 RD R 1-1 RC,RF 4 ENTRY c f c fa a a a a c f a 7 (TYP.) VO VO D.M. OFFICE OFFICE RD BC, BF RC, RF RD RD VO RC,RF RED NETWORK RACK a 1035 RD c f a a R 1-4 RD a a c f RD RD RD R RD 1-5 2 PERSON 234 VO OFFICE B 1-5 RD 234 VO c f MATCHLINE - FOR CONTINUATION SEE DRAWING 102724/E6 RD 3 c f RD c f RD c f 1052 a a c f a LOBBY 234 VO VO VO VO VO 1028 B 1-3 CORR. 1048 RD VO CORR. 4 1034 VO a a c f 1 ALCOVE E.W.C. 1031 ELEV. VEST. PASSENGER PASSENGER ELEVATOR ELEVATOR #1 #2 D UP MATCHLINE - FOR CONTINUATION SEE DRAWING 102724/E26 A B A.6 C SCALE: 1. SEE DRAWING NO. 102741/E1-E3 FOR ELECTRICAL EQUIPMENT LIST. 1 INDICATES PRESET INSERTS, SUPPLIED WITH CELLULAR FLOOR SECTIONS. 2. FOR COORDINATION OF SPACES ON FLOOR AND CEILING LEVELS IN UTILITY CHASE 2 1" RIGID CONDUIT IN TOPPING SLAB, SEE AREA, SEE MECHANICAL DRAWINGS. ‚" = 1'-0" HSM 09-04 88153 C 102724/E5 EP 5746 102745/E1 WEST 3 3. SEE RESPECTIVE "RECEPTACLE AND UNDERFLOOR POWER PLAN" FOR EQUIPMENT ITEM D C.6 1ST FLOOR SIGNAL AND TELEPHONE SYSTEM PLAN - EAST KEYED NOTES GENERAL NOTES B.4 TW-0682 1-1" CONDUIT. AW-1628 DESIGNATIONS UNLESS SPECIFICALLY NOTED OTHERWISE. 4 2-3" CONDUITS. 4. SEE DRAWING NO. 102729/E3 FOR VOICE AND DATA ONE-LINE DIAGRAM. 218935 WEST-CENTER 5 5. SEE DRAWING NO. 102745/E1 FOR UNDERFLOOR DUCT SYSTEM DETAILS. D 10/08 HSM CONSTRUCTION REV-0 EEA EEA C 2/98 ADD VOICE DROP, ROOM 1032 RDG RB B 2/97 AS-BUILTS PER CONTRACTOR MARKUPS RCG DAP E 07/20 810 GENERATOR VLM WDH P.O. 2-3/4" CONDUITS. REV DATE DESCRIPTION DWN CKD PROJECT NO. 6 1-4" CONDUIT DOWN TO BASEMENT TELEPHONE ROOM. 7 CABLE TRAY, SEE ELECTRICAL EQUIPMENT SCHEDULE. 8. ALL CONDUITS ARE ƒ" EMT UNLESS NOTED OTHERWISE. 8 ƒ" CONDUIT WITH 1-4 PR., CAT. 5 UTP CABLE. 9. ALL RED DATA SYSTEMS CONDUIT FITTINGS ARE WELDED OR EPOXYED. 9 2-1" EMT CONDUITS WITH PULL STRING, ROUTED TIGHT TO DECK 6. SEE DRAWING NO. 102729/E4 FOR PDS ONE-LINE DIAGRAM. 7. ALL CONDUITS CONCEALED IN FLOOR ARE A MINIMUM 6" BELOW BOTTOM U.S. DEPARTMENT OF ENERGY EAST-CENTER NNSA/SANDIA SITE OFFICE ALBUQUERQUE, NEW MEXICO OF SLAB. EAST P.O. 1ST FLOOR SIGNAL AND TELEPHONE PLAN - EAST FROM NEW BOILER CUB PIPE TRENCH TO 1ST FLOOR IDR. PROJECT NO. 10. VOICE/OPEN DATA AND RED DATA OUTLET BOXES ARE SEPARATED BY A MINIMUM OF 18". 11. ALL CONDUIT RUNS AND MIXING BOXES ARE INSTALLED AT, OR NEAR, D THE BASE OF THE STRUCTURAL TEES. 3.SEE DRAWING TN7002810 FOR TELECOM ONE-LINE DRAWING. 10 INSTALL 1F SINGLEMODE OSP CABLE IN 1" CONDUIT. CENTER FOR NATIONAL SECURITY KEYED PLAN 11 TERMINATE CABLE ON WALL WITHIN EXISTING LIU WITH FUSE ON SC/APC CONNECTORS AND PATCH FIBER INTO FDH PASS THRU PORTS IN EXISTING FDH. REFER TO T-4001810 FOR LOCATION OF EXISTING EQUIPMENT. COORDINATE WITH ORG 10775. DRAWN BY CHECKED BY ARMS CONTROL N.T.S. SNL ENGR DISCP:T DISCP: OLD FILENAME: 0 2' 4' of E SANDIA NATIONAL LABORATORIES 8' 12' FILENAME: 102724E.05 TN1005810.DGN Bohannan SUB-DISCP:N SUB-DISCP: Huston Courtyard I 7500 Jefferson St. NE Albuquerque, NM 87109 (505) 823-1000 810 SIZE D+ DATE DRAWING NO TN1005810 APP SEQ. FMOC. " C111 TELEPHONE CABINET "810BD1"30 of C110 expressed authorization MECHANICAL FREIGHT ELEVATOR #1 al l ow ed w ithout the RECEIVING al teration 103 No VESTIBULE SIGNAL CABINET "810QC" 29 Sandia NationalLaboratories Facil ities Managem ent and Operation STAIR " Property 1030 Center ( FMOC) . EAST - PAG E 5304477 FO R SN L SU RVEY. GENERAL NOTES 1. ALL EQUIPMENT SHOWN IS EXISTING UNLESS NOTED OTHERWISE. 2. FOR TERMINATION CABINET DETAILS, SEE T-5001TA1/166. 3. PULL, TERMINATE, TEST, LABEL AND DOCUMENT ALL CABLES. 4. ALL PVC CONDUITS ARE CONCRETE ENCASED. 5. BUILDING REQUIRES SPECIAL ACCESS PROCEDURES. 6. FOR ACCESS CONTROL/INTRUSION ALARM RISER DIAGRAM, SEE TY7005810/60. 7. FOR TELECOMMUNICATIONS RISER DIAGRAMS, SEE TN7001810/61 AND HIRSCH MODEL 8 4-4" CONDUIT (BELOW) TO CMMH-1 9A 2 - TRUNK MM MM MM MM MM MM D MM D MM MM MM MM FAN COIL MM TJ7001810/62. C. 5 C. 5 C. 6 STARTER PANEL SINK 8. "PIDR1" FOR INTER-BUILDING TELECOMMUNICATIONS EQUIPMENT SCHEDULE, SEE T-6002TA1/169. 2 810 B2E B2D B2C B2B B2A A T-4001810 T-4001810 KEYED NOTES C 810 EWC 810 E 810 C 810 8102FC SM TOP 3, BOTTOM 2 - TRUNK 5 B. 6 18 FR1S0056 FR1S0057 MM MM MM MM MM SM 13 MM MM 6 MM MM MM MM E MM FB1S0128 18 18 SM FR1S0054 FR1S0055 MM 19 MM 810 MM 13 6 18 9 19 810 R3E TOP 3, BOTTOM A. 8 MM 1042 6 22 MM B3E 810 B3D 19 R2C R2B R2A R3C 9 ROWS - SM 10 ROWS - SM B3C MM 810 R3B B3B 810 3FA B3A IDR3 MM TRUNK A MM MM MM MM INSTALL RED 2" CONDUIT WITH FIBER CABLES (2). B 12 BOND #4/0 GROUND CONDUCTOR FROM DUCT BANK TO EXISTING #4/0 GROUND BUILDING 810 - BASEMENT 4 INSTALL CONTROL PULLBOX FOR BOTH TELECOMMUNICATIONS AND ACCESS CONTROL/INTRUSION ALARM. SCALE: TABLE 1" = 20'-0" FILE 8103FD INSTALL LIGHTGUIDE INTERFACE UNITS (LIU'S) AND TROUGHS FOR TERMINATION OF NEW FIBER TRUNK CABLES. 14 TABLE TRUNK MM INSTALL #4/0 GROUND CONDUCTOR FROM DUCT BANK IN 1" CONDUIT. 13 810 3FC MM TOP 3 - MM 11 CONDUCTOR LOCATED IN EXISTING 4" CONDUIT. 2 10 MM TRANSITION FROM CONCRETE ENCASED PVC CONDUITS TO RIGID WRAPPED OR PVC TO CMMH-21B 810 3FB 2098 TOP 3 - SM MM 9 10 4 R3A 4-4" CONDUIT 5 810 6 SM 810 7 MM MM INSTALL BLACK 2" CONDUIT WITH FIBER CABLES (2). COATED CONDUIT. 3 5' 8 SM T-4001810 8 228 14 MM T-4001810 INSTALL 5" CONDUIT WITH 1-900 PAIR OSP CABLE. A 810 9 SM MM 7 10 A MM MM INSTALL 4" CONDUIT WITH RED (2) AND BLACK (2) FIBER CABLES. 1 R2D MM 2 R2E 810 810 A. 2 810 3 810 E 810 MM 6 11 4.7 810 MM UP THROUGH FLOOR TO IDR 2, SEE THIS DRAWING. MM E R3D A. 5 810 MM MM 810 ES-FS0030 5 22 MM A. 5 2 - MM TRUNK 4.3 STARTER 8102FD INSTALL SECURITY 2" CONDUIT WITH FIBER. UP SM TRUNK MM FAN COIL 3.7 FILE FB1S0127 E 13 4 11 2 - SM TRUNK IDR2 INSTALL PULLBOX. G 15 TOP 3, BOTTOM 19 3 B 13 7 ROWS SM CONTINUATION. 20 B. 4 8 4 E FB1S0126 EWC FB1S0125 SM 7 ROWS SM 7 B EXISTING 8102FE 4-5" TO MANHOLE CMMH-227. SEE DRAWING G-0004ECIM/11 FOR 15 UP SM SM 2 2 SM EXISTING 8102FA INSTALL SECURITY COMMUNICATIONS CABINET. 3.3 8102FB 1 15 INSTALL NEW CABLES IN EXISTING CONDUITS UP THROUGH FLOOR TO IDR 3, SEE THIS DRAWING. 233 1 PANEL C 16 7 6 3 SCALE: BUILDING 810 - IDR3 - ROOM 2098 ‚" = 1'-0" SCALE: R A M U P P BUILDING 810 - IDR2 - ROOM 1042 D D 1 EXISTING SPLICE. UP BEFO RE DIG G IN G O R BACK FILLIN G TOP 3, BOTTOM (ABOVE), SECURITRON ‚" = 1'-0" T-4001810 T-4001810 T-4001810 UP T-4001810 C. 5 C. 6 P M A R P U UP 1 UP UP T-4001810 C C E. W. C. T-4001810 21 R A M P ICE MACHINE U D. W. P B. 5 5 400 PROTECTORS IDR 1 15 258 B. 2 B. 2 B. 4 8 4" CONDUIT IDR 2 4 600 PROTECTORS SPARE 4" G 12 UP 11 7 REF. B. 8 B 9 3 8 DN 3 258 17 B B 16 VOICE FRAME "IM1" A. 5 A. 6 UP UP A. 6 B03 A. 7 TELEPHONE ROOM ISDN "IM2" UP A. 2 UP A A ACU CABINET KEYED NOTES CONTINUED UP BUILDING 810 - MAIN VOICE ENTRANCE ‚" = 1'-0" T-4001810 17 INSTALL 1-900 PAIR OSP VOICE CABLE TO EXISTING SPLICE. INSTALL 710 BRIDGE TAP (PART #710-BD1-25). TERMINATE CABLE ON BRIDGE TAP. CONNECTIONS TO 1 2 3 4 5 6 7 9 8 EXISTING 710 MODULES BY SNL TELECOMMUNICATIONS GROUP. 10 SCALE: ADDITIVE ALTERNATE 2B UP 2 T-4001810 BUILDING 810 - 1ST FLOOR INSTALL NEW FIBER CABLES (2) IN EXISTING 4" CONDUIT. 19 ROUTE NEW CABLES THROUGH EXISTING CABLE TRAYS TO NEW LIU'S. 20 INSTALL LISTED FIRESTOP ASSEMBLY. 21 EXISTING VOICE CABLE CA32: 5301-5400, 6001-6600, 4201-4300, 4701-4900. 22 EXISTING PULLBOX. D 1" = 20'-0" D SCALE: 18 18 UP B B IDR 3 233 FLOOR A. 5 A. 5 MM UU'S A. 8 1 A. 2 UP 218935 7/20 A VLM WDH 810 GENERATOR P.O. REV DATE DESCRIPTION DWN CKD APP PROJECT NO. 4.3 U.S. DEPARTMENT OF ENERGY 4.7 A A 3.7 SCALE: 3.3 A BUILDING 810 - IDR2 - ROOM 1042 - WEST WALL ELEVATION NNSA/SANDIA SITE OFFICE ALBUQUERQUE, NEW MEXICO ‚" = 1'-0" SANDIA NATIONAL LABORATORIES P.O. FLOOR PLANS AND ELEVATIONS - COMMUNICAT 1 2 3 4 5 6 7 PROJECT NO. BUILDING 810 - 2ND FLOOR DRAWN BY Center For National Security SCALE: 1" = 20'-0" 4' 2' 0 CHECKED BY 4' Arms Control SNL ENGR of 8 9 T-4001810 10 T-4001810 SCALE 1"=4' 20' 10' 10' 0 DISCP:T 20' OLD FILENAME: SCALE 1"=20' FILENAME: T-4001810.DGN T-4001810.DGN 810 SUB-DISCP:SIZE E DATE DRAWING NO. 12/03/2002 SEQ. T-4001810 FMOC. " 18 expressed authorization of EWC CABLE TRAY Sandia NationalLaboratories Facil ities Managem ent and Operation Center ( FMOC) . #2 #1 T-4001810 4 al teration al l ow ed w ithout the ELEVATOR ELEVATOR SINK T-4001810 " Property PASSENGER PASSENGER 3 CEILING No C. 5 C C EWC UP SINK C. 5 C. 6 UP GROUND BUS OFFICIAL USE ONLY GENERAL NOTES B 2-6 6 1 C (B) 2038 C (B) 2045 C (B) 2041 C (B) 2047 6 3 6 5 B KEYED NOTES 1 EXISTING BLACK COMMUNICATIONS BOX, CONDUIT AND CONDUCTORS TO NEAREST WALL AND TEST. 4 C (B) 2030 C (B) 2032 C (B) 2034 C (B) 2034 1 C (B) 2034 1 C (B) 2034 C (B) 2036 C (B) 2039 C (B) 2040 C (B) 2042 4 C (B) 2043 C (B) 2044 1 C (B) 2044 C (B) 2046 C (B) 2046 C (B) 2048 C (B) 2055 C (B) 2055 C (B) 2055 1 SECOND FLOOR 2 EXISTING BLACK NETWORK RACK. 3 EXISTING PULLBOX. 4 BLACK COMMUNICATIONS BOX. 5 1-1" CONDUIT FROM BLACK COMMUNICATIONS BOX TO BLACK PULL BOX. 6 3 CAT5E, 1-4 FIBER MULTIMODE AND 1-4 FIBER SINGLE MODE FROM BLACK COMMUNICATIONS BOX TO IDR ROOM. EXISTING CONDUIT FROM BLACK PULL BOX TO IDR ROOM. 7 INSTALL 1F SINGLEMODE CABLE IN 1" CONDUIT. 8 INSTALL GPON ONT OUTLET. SEE T-5001STD FOR DETAILS. B 8 7 SUB SCALE: NTS 164145 A 9/13 218935 B 07/20 810 SECOND FLOOR MODS - AS BUILTS EKC JOS 810 GENERATOR VLM WDH P.O. REV DATE DESCRIPTION DWN CKD APP PROJECT NO. U.S. DEPARTMENT OF ENERGY NNSA/SANDIA SITE OFFICE ALBUQUERQUE, NEW MEXICO SANDIA NATIONAL LABORATORIES P.O. BLACK RISER DIAGRAM Center For National Security Arms Control PROJECT NO. 164145 DRAWN BY E.COOPER CHECKED BY J.SLATER SNL ENGR DISCP: OLD FILENAME: OFFICIAL USE ONLY FILENAME: TN7002810.DGN T Bohannan SUB-DISCP: N Huston Courtyard I 7500 Jefferson St. NE Albuquerque, NM 87109 (505) 823-1000 810 SIZE D+ DATE DRAWING NO TN7002810 9/27/2012 SEQ. FMOC. " of expressed authorization BLACK RISER DIAGRAM al l ow ed w ithout the FIRST FLOOR al teration LIU No 1042 EX of BLACK IDR " Property 2 Sandia NationalLaboratories Facil ities Managem ent and Operation Center ( FMOC) . B GENERAL NOTES ONT 10 ONT 10 9 9 7 7 6 SEE DETAIL 3/T5002STD BOX # REFER TO SPECIFICATION 270005. 2. SEE DRAWING NO. T-6001STD FOR TELECOMMUNICATIONS EQUIPMENT SCHEDULE. 3. ONT MUST BE MOUNTED WITHIN 5' OF A 120V RECEPTACLE. 4. INSTALL ONT TO SUPPORT BRACKET WITH 2 MOUNTING SCREWS. USE APPROPRIATE ANCHORS FOR WALL. SUPPORT BRACKET IS TO BE MOUNTED LEVEL. 5. USER OUTLET ID STICKERS PROVIDED BY SFM. 9 9 6 1. 21A SERIAL # BOX # 8 SERIAL # KEYED NOTES 2 1 8 18 SECURE DATA CIRCUIT 12 12 1 OUTLET ID STICKER (SFM). 2 INSTALL GPON / VOICE OUTLET AS REQUIRED. SYSTIMAX ANGLED 2 PORT FACEPLATE, PROVIDE AND INSTSALL INSERT ON DROP WITH NO VOICE CABLES 3 SC COLLAR AND SC ADAPTER 4 COIL EXCESS CABLE AND ONT POWER SUPPLY IN ONT SUPPORT BRACKET. 5 INSTALL ONT ON MOUNTING BRACKET, TABS DOWN 6 ONT SERIAL NUMBER SFM 7 DROP BOX NUMBER 8 LASER CAUTION STICKER. (SFM) 9 INDUSTRIAL STRENGTH SELF-ADHESIVE CABLE TIE MOUNT. SECURE CABLE TO MOUNT WITH ZIP TIE. 10 POWER SUPPLY 11 JUMPER (1 METER) ROUTE EXTRA FIBER ON ONT BRACKET 12 USING A MECHANICALLY GENERATED METHOD, I.E. A LABEL MAKER, PLACE A LABEL STATING THE FOLLOWING INFORMATION, "INSTALLED BY (INSTALLER'S NAME), (CONTRACTOR NAME), (dB LOSS), (DATE INSTALLED 00/00/0000.), (POWER LEVEL READING)", SEE DETAIL 7/T-5001. APPLY CONTRACTOR LABEL ON BACK OF ONT. LABEL SHALL HAVE A BLACK BACKGROUND WITH WHITE LETTERING/NUMBERS. 13 VINYL SELF-LAM XSL-103-427 BLACK ON WHITE 1" x 1.25" x .5" OR EQUIVALENT. LABEL ON EACH END OF CABLE 14 CCHD STICKER (SFM) 15 CONTRACTOR TO FURNISH AND INSTALL ALL PATCH CORDS TO COMPLETE SYSTEM. CALL 844-2216 BEFORE REMOVING BOX SNLA 31 624 ID NO. 57 LASER HAZZARD CAUTI ON LASER HAZZARD CAUTI ON CAUTION - DO NOT REMOVE THIS TAG 20 57 SECURE DATA CIRCUIT CALL 844-2216 BEFORE REMOVING BOX SNLA 1 31 624 ID NO. CAUTION - DO NOT REMOVE THIS TAG 13 CCHD 845-2243 - DO NOT REMOVE OR POWER OFF 3 13A CCHD 845-2243 - DO NOT REMOVE OR POWER OFF 14 14 5 5 3 4 57A 13 13A 4 57A 7 11 7 11 54 4 4 9 9 2 TYPICAL USER 140C ONT OUTLET TO GPON / VOICE OUTLET SCALE: NTS 9 TYP. ONT POWER SUPPLY CORD (TYP) T-5007 T-5007 10 120V DUPLEX RECEPTACLE 1 57B OLT SECURE DATA CIRCUIT LABELING DETAIL: LINE 1: SATL(MDR) - ROOM# - OLT# LINE 2: PORT - (OLT CARD#) - (CARD PORT #) LINE 3: FIBER NAME CALL 844-2216 BEFORE REMOVING BOX SNLA 31 624 ID NO. CAUTION - DO NOT REMOVE THIS TAG 22 LABELING EXAMPLE: LINE 1: SATL880-X57-1 LINE 2: PORT - PORT 1-1 LINE 3: FB1SXXXX-XX CARD PORT #3 CARD PORT #4 3 LIU TYPICAL VOICE OUTLET SCALE: NTS T-5001 NEW SM JUMPER 15 56 OLT CARD #1 SPECIAL NOTES: T-5001 #2 #3 #4 #5 #6 #7 #8 SANDIA USE ONLY #9 #10 #11#12 #13#14 #15 #16 SANDIA USE ONLY - PORTS ON OLT CARDS ARE SC/UPC ONLY BEAM - CONNECTOR TYPES VARY IN LIU & LST 1U BEAM 4 GPON CONNECTIVITY & LABELING DETAIL (OSP TO OLT) SCALE: NTS T-5001 T-5001 BEAM CLAMP LABELING DETAIL: LINE 1: BLDG - FDH (or) FSB-XX-MDR LINE 2: SPLITTER-XX LINE 3: FIBER NAME FB1SXXXX-XXX 3/8" ALL THREAD BEAM CLAMP BEAM CLAMP 3/8" ALL THREAD LABELING EXAMPLE: LINE 1: 727-FDH-01-880 LINE 2: SPLITTER-01 LINE 3: FB1SXXXX-XX FDH 3/8" ALL THREAD 44 OR 45 OR 46 OR 46A FIBER SHELF 1 5/8" CHANNEL SUPPORT 13 42 727-FDH-01-880 SATL880-X57-1 SPLITTER - 1 PORT 1-1 FB1SXXXX-XX FB1SXXXX-XX 43 LIU NEW SM JUMPER UPDATES TO TELECOM STD. DWGS. KNH TBM TLH B 11-3-16 UPDATED FIBER DWGS KSH TBM TLH A 3-5-14 UPDATES TO TELECOM STD DWGS. KLT CG KRC JM DATE DESCRIPTION DWN CKD APP U.S. DEPARTMENT OF ENERGY 55 NNSA/SANDIA SITE OFFICE SPECIAL NOTES: SIDE (OR) FSB ALBUQUERQUE, NEW MEXICO P.O. Communications Black User Outlet Details - SPLITTERS ARE SC/APC ONLY PROJECT NO. - CONNECTOR TYPES VARY IN LIU & LST 1U Standards 52 DRAWN BY of RDT LABELING DETAIL SCALE: NTS T-5001 1-8-18 CH SANDIA NATIONAL LABORATORIES RDT 5 C REV FRONT REAR UPDATES TO TELECOM STD. DWGS. PROJECT NO. 1 5/8" CHANNEL SUPPORT RDT 6-25-19 P.O. RDT LABEL RDT LABEL JP D CHECKED BY T-5001 6 RDT BEAM MOUNTING DETAIL 7 GPON CONNECTIVITY & LABELING DETAIL (OSP TO FDH/FSB) SCALE: NTS SCALE: NTS T-5001 T-5001 SNL ENGR T-5001 T-5001 DISCP: OLD FILENAME: FILENAME: T SUB-DISCP: STD SIZE T-5001STD.DGN T-5001STD.DGN - A Joint Venture D+ DATE 11/06/2013 DRAWING NO SEQ. T-5001STD SAND20XX-XXXXXXX FMOC. " FB1SXXXX-XX T-5007 of FB1SXXXX-XX CARD PORT #2 expressed authorization PORT 1-1 al l ow ed w ithout the SATL880-X57-1 PORT 1-1 al teration SATL880-X57-1 No TYPICAL USER 140C ONT OUTLET TO EXISTING SINGLEMODE FIBER DROP SCALE: NTS T-5007 CARD PORT #1 Sandia NationalLaboratories Facil ities Managem ent and Operation 1 13 " Property FIBER SHELF 21B Center ( FMOC) . 57C