Emerson Climate Technologies (India) Limited COMPRESSOR MODEL KCM475LAL-CXXXH BILL OF MATERIALS C310H, C311H Emerson Climate Technologies (India) Limited Karad Dhebewadi Road Karad - 415 110 INDIA Note – Sales compressor drawing number and compressor model name are the same. SC1 Prepared by Checked by Verified by Approved by 1 F42-1109-0876 Current EN No. A1 29.11.2009 Page No. ----Last EN No. REV. No. DATE PED-QSP-ORG-02/09 Emerson Climate Technologies (India) Limited PRODUCT SPECIFICATION MODEL – KCM475LAL-CXXXH A) MODEL DESCRIPTION Model Name Compressor Type Application Group Evaporating Temperature Range Refrigerant Rated Voltage Compressor Cooling Typical Applications Certifications & Approvals KCM475LAL-CXXXH Reciprocating ,Connecting Rod Type Low temperature (LBP) -37.2 °C to –6.7 °C ( -35°F To R-404A 230V, 1Phase, 50Hz FAN – 350 CFM Cold Room Application , Deep Freezer ---- B) PERFORMANCE SPECIFICATION @ RATED CONDITION Specification Unit Btu / h kcal / h W Nominal HP W Cooling Capacity Input Power Input Current Cooling Capacity EER = Input Power LBP 5700 1436 1670 1.7 1250 A 6.8 Btu / W-h 4.56 kcal / W-h 1.15 S P E C I F I C A T I O N W/W 1.34 Note – Above performance parameters are nominal values & subject to + 5% variation C) RATING CONDITIONS Parameter Evaporating Temperature Condensing Temperature Ambient Temperature Sub cooled Liquid Temp. Return Gas Temperature Test Voltage Unit °C ( °F ) °C ( °F ) °C ( °F ) °C ( °F ) °C ( °F ) V SC1 Prepared by Checked by Verified by Approved by LBP @ ASRE/T -23.3 (-10) 54.4 (130) 32 (90) 32 (90) 32 (90) 230 2 F42-1109-0876 Current EN No. A1 29.11.2009 Page No. ----Last EN No. REV. No. DATE PED-QSP-ORG-02/09 Emerson Climate Technologies (India) Limited PRODUCT SPECIFICATION MODEL – KCM475LAL-CXXXH D) MECHANICAL SPECIFICATION Parameter Number of Cylinders Displacement Net Weight Approximate Shipping Weight Oil Charge Oil Type IPRV ( Pressure Differential ) Crank Case Heater Unit Number (s) cm3 ( inch3 ) / rev kg Value Two ( 2 ) 51.47 (3.141) 32.5 kg 33.1 cm3 Refrigeration Grade 1300 POE kg / cm2 ( psig ) 31.65 / 38.68 (450 / 550) W/V 58 @ 220/240 E) ELECTRICAL SPECIFICATION Parameter Operating Voltage Range Motor Circuit Electrical Accessories Start Capacitor Run Capacitor Relay Over Load Protector Lock Rotor Ampere ( LRA ) Maximum Continuous Current ( MCC ) Motor Insulation High Potential Test Unit V ----F @ V AC F @ V AC ----A Value 198-264 CSR 150/200 mfd. 25 mfd AC 85004 Internal 72 A 13 --(kV/second/mA) Class B 1.85 / 1 / 5.5 o CONDENSING TEMPERATURE ( F) F) OPERATING ENVELOP @ 230 V, 50 Hz, 1 Phase 150 140 130 120 110 100 90 -40 -35 -30 -25 -20 -15 -10 -5 0 Checked by 10 15 20 25 o SC1 Prepared by 5 EVAPORATING TEMPERATURE ( F) Verified by Approved by S P E C I F I C A T I O N 3 F42-1109-0876 Current EN No. A1 29.11.2009 Page No. ----Last EN No. REV. No. DATE PED-QSP-ORG-02/09 Emerson Climate Technologies (India) Limited PRODUCT SPECIFICATION MODEL – KCM475LAL-CXXXH PERFORMANCE TABLES Return Gas Temp. Liquid Sub Cooling Ambient Temp. 32°C (90°F) 230V, 1Ph, 50Hz Voltage Compressor Cooling - 32°C (90°F) 32°C (90°F) 350 ft3 / minute - A) COOLING CAPACITY ( Btu / h ) Condensing Temperature °C 37.8 43.3 48.9 54.4 60.0 (°F) 100 110 120 130 140 Evaporating Temperature -37.2 (-35) 3583 2990 ---- -31.7 (-25) 5200 4630 4000 3320 -- -23.3 (-10) 7660 6870 6540 5700 4900 -17.7 (0) 10400 9770 9000 8800 7530 -12.2 (10) 13920 12800 12300 11550 10490 -6.7 (20) 18460 16950 16000 14970 14180 B) INPUT POWER ( W ) Condensing Temperature °C 37.8 43.3 48.9 54.4 60.0 (°F) 100 110 120 130 140 Evaporating Temperature -37.2 (-35) 760 860 ---- -31.7 (-25) 860 970 1100 1189 -- -23.3 (-10) 950 1060 1160 1250 1410 -17.7 (0) 1060 1175 1310 1470 1580 -12.2 (10) 1256 1450 1645 1760 1910 -6.7 (20) 1650 1890 2070 2180 2256 C) INPUT CURRENT ( A ) Condensing Temperature Evaporating Temperature °C -37.2 -31.7 -23.3 -17.7 -12.2 -6.7 (°F) (-35) (-25) (-10) (0) (10) (20) 4.9 5.1 5.5 5.9 6.8 8.4 37.8 100 5.1 5.4 6.0 6.5 7.4 8.7 43.3 110 -5.8 6.3 6.8 7.9 8.9 48.9 120 -6.2 6.8 7.0 8.1 9.2 54.4 130 --7.1 7.6 8.4 9.4 60.0 140 Note – 1. Nominal performance values (+ 5%) based on 24 hours running. Subject to change without notice. 2. Compressor is intended to be operated in the range of condensing & evaporating temperature where performance values are specified in above tables. SC1 Prepared by Checked by Verified by Approved by S P E C I F I C A T I O N 4 F42-1109-0876 Current EN No. A1 29.11.2009 Page No. ----Last EN No. REV. No. DATE PED-QSP-ORG-02/09 Emerson Climate Technologies (India) Limited DESIGN SPECIFICATION MODEL – KCM475LAL-CXXXH A) MECHANICAL SPECIFICATION Parameter Unit Value Cylinder Bore Diameter Crank Shaft Eccentricity Crank Shaft Stroke Approximate Internal Free Volume (Without Oil) Maximum Residual Moisture Maximum Internal Solid Residue / Impurities cm ( inch ) cm ( inch ) cm ( inch ) 4.21 (1.656 ) 0.93 ( 0.365 ) 1.85 ( 0.729 ) cm3 (inch3) 7,000 ( 427 ) mg 300 mg 40 B) ELECTRICAL SPECIFICATION Parameter Unit Value Motor Type Nominal Motor Speed Main Nominal Motor Winding Resistance ( @ 25 °C ) Aux. Nominal Motor Output Power Maximum Motor Temperature Relay Type Part Number Pick Up ( Maximum ) Drop Out ( Minimum ) Maximum Voltage Rating of Coils Over Load Protector Type --rpm 2 Pole, Induction, Single Phase 2,900 0.93 To 1.09 Part Number Ω Ω kW ° F (°C) 3.63 To 4.17 1.5 266 (130) ----V V Potential AC85004 165 To 185 65 To 95 V 430 --- Internal 15HM-1484-78 or 5DN-0484-78 239 To 257 (115 To 125) 126 To 158 (52 To 70) 53 2 To 10 ¼ “ Quick connector Hermetic Grade Round Enameled H Class Base Coat – 65-75% of Polyster Imide Top Coat – 25-35 % of Polyamide Imide --- Disc Opening Temperature Disc Closing Temperature 1st cycle trip Current 1st cycle trip On time Terminal Fused Cluster Copper Wire Material Copper Wire Enamel Designation °F (°C ) °F (°C ) A Second ------- Copper Wire Enamel Construction --- SC1 Prepared by Checked by Verified by Approved by S P E C I F I C A T I O N 5 F42-1109-0876 Current EN No. A1 29.11.2009 Page No. ----Last EN No. REV. No. DATE PED-QSP-ORG-02/09 Emerson Climate Technologies (India) Limited DESIGN SPECIFICATION MODEL – KCM475LAL-CXXXH C) PERFORMANCE SPECIFICATION Parameter Unit Bare Compressor Sound Bare Compressor Vibration Compressor Discharge Pulse dBA m psi Value 65 maximum 80 maximum 3 maximum D) TEST CONDITIONS Parameter Unit Test Voltage V Suction Pressure Discharge Pressure kg/cm2 (psig) kg/cm2 (psig) Top Shell Temperature Ambient Temp °C ( °F ) °C ( °F ) 198 230 260 230 3.18 (45) 30.7 (437) 80 (176) 43 (109) 1.62 (23) 26.4 (375) --- --- 198 8 (114) 15 (213) 70 (158) 43 (109) Equalised 198 14 (199) 14 (199) 70 (158) 43 (109) Low Voltage Run 198 3.18 (45) 30.7 (437) 80 (176) 43 (109) Overload (High Load) Blocked Fan Low Voltage Start : Unequalised Note – Above test conditions are only for reference and not for customer product qualification E) REFERENCE APPLICATION DETAILS Parameter Allowable Maximum Ambient Temperature Maximum Permissible Transient Discharge Pressure Stabilised Maximum Discharge Line Temp. Maximum Return Gas Temp. Unit Value ° C (°F) 43 (109) kg / cm2 ( psig ) 29.4 (420) 28.4 (400) 120 (248) 37.5 (99.5) ° C (°F) ° C (°F) Note – Application Details are the guidelines for safe operation of Compressor. SC1 Prepared by Checked by Verified by Approved by S P E C I F I C A T I O N 6 F42-1109-0876 Current EN No. A1 29.11.2009 Page No. ----Old EN No. REV. No. DATE PED-QSP-ORG-02/09