AFW A-11A, Saubhagya, Jeevan Vikas Kendra Road, Andheri-E, Mumbai-400 069, India, Phone:(91 22) 2682 6890/7549, FAX: (91 22) 2683 7873, E-MAIL: afwmumb@gmail.com , Website:http://www.afwcable.com Fire Survival Cables- Copper Conductor, Armoured, Zero Halogen ¾ Voltage Grade: Up to 1000 V ¾ Designed as per IEC 60502-1:2004 / BS 7846:2009 ¾ Cable Size: Up to 4 Cores, 1.5 sq. mm.- 185 sq. mm. ¾ Conductor Type: Annealed Electrolytic Bare/ Tinned Copper (Class 1/ 2) ¾ Insulation Material: Glass Mica + Ethylene Propylene Rubber ¾ Sheathing Material: Special Low Smoke Zero Halogen Compound ¾ Armour: Galvanized Steel Wire ¾ Colour Codes: As per customer’s requirement ¾ Packing: Wooden Drums ¾ Fire Resistance: BS 8491/ BS 8434-2/ BS EN 50200 + Annex. E/ IEC 331:2009 (1&2) / BS 6387 CWZ ¾ Low Smoke Emission: Light Transmittance > 60 % as per IEC 61034 ¾ Flame Retardant: As per IEC 60332 ¾ Halogen Free: Acid Gas Less than 0.5 % as per IEC 60754 ¾ Min. Bending Radius: 12 x O.D. Nom. cross sectional area (sq. mm.) Overall dia. (mm, +/-3 mm) Approx. dia. Under armour (mm,+/-3 mm) 1.5 2.5 4 6 10 16 25 35 50 70 95 120 150 185 13.6 14.5 15.6 16.7 18.5 21.5 25.3 28.1 31.8 35.9 39.8 44.0 48.7 53.9 9.3 10.2 11.3 12.4 14.2 16.7 20.5 23.1 26.6 30.5 34.2 38.2 42.5 47.3 Approx. Nom. thickness/ dia. of armour wires (mm) 2 Core 0.9 0.9 0.9 0.9 0.9 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 Approx. cable weight (kg/km) 345 401 475 561 711 976 1337 1656 2169 2790 3446 4287 5253 6328 Max. Cond. Res. at 20°C (ohms/km) 12.3 7.56 4.70 3.11 1.84 1.16 0.734 0.529 0.391 0.270 0.195 0.154 0.126 0.100 The actual dimensions shall be subject to revision at the time of final engineering and shall be as per our datasheet submitted at the time of order -1- AFW A-11A, Saubhagya, Jeevan Vikas Kendra Road, Andheri-E, Mumbai-400 069, India, Phone:(91 22) 2682 6890/7549, FAX: (91 22) 2683 7873, E-MAIL: afwmumb@gmail.com , Website:http://www.afwcable.com Nom. cross sectional area (sq. mm.) Overall dia. (mm, +/-3 mm) Approx. dia. Under armour (mm,+/-3 mm) 1.5 2.5 4 6 10 16 25 35 50 70 95 120 150 185 14.3 15.3 16.4 17.7 19.9 22.7 26.9 29.9 33.7 38.1 42.4 47.1 52.3 57.2 10.00 11.00 12.1 13.4 14.9 17.9 21.9 24.7 28.5 32.7 36.6 40.9 45.9 50.6 Nom. cross sectional area (sq. mm.) Approx. Overall dia. (mm, +/-3 mm) Approx. dia. Under armour (mm,+/-3 mm) 25 35 50 70 95 120 150 185 28.2 30.8 34.9 40.0 44.1 49.2 54.4 59.9 23.2 25.6 29.5 34.2 37.9 42.8 47.8 52.7 Nom. cross sectional area (sq. mm.) Approx. Overall dia. (mm, +/-3 mm) Approx. dia. Under armour (mm,+/-3 mm) 1.5 2.5 4 6 10 16 25 35 50 70 95 120 150 185 15.3 16.4 17.7 19.1 21.6 24.6 29.8 32.6 37.0 42.6 46.9 52.3 57.7 63.6 11.00 12.1 13.4 14.8 17.0 19.8 24.8 27.4 31.6 36.8 40.7 45.9 51.1 56.4 Approx. Nom. thickness/ dia. of armour wires (mm) 3 Core 0.9 0.9 0.9 0.9 0.9 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 Nom. thickness/ dia. of armour wires (mm) 3.5 Core 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 Nom. thickness/ dia. of armour wires (mm) 4 Core 0.9 0.9 0.9 0.9 0.9 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 Approx. cable weight (kg/km) 375 442 534 641 842 1152 1584 1989 2633 3428 4311 5350 6575 7949 Approx. cable weight (kg/km) 1731 2200 2903 3814 4782 5975 7345 8903 Approx. cable weight (kg/km) 420 503 614 745 991 1372 1878 2411 3173 4200 5253 6596 8115 9856 Max. Cond. Res. at 20°C 12.3 7.56 4.70 3.11 1.84 1.16 0.734 0.529 0.391 0.270 0.195 0.154 0.126 0.100 Max. Cond. Res. at 20°C 0.734 0.529 0.391 0.270 0.195 0.154 0.126 0.100 Max. Cond. Res. at 20°C 12.3 7.56 4.70 3.11 1.84 1.16 0.734 0.529 0.391 0.270 0.195 0.154 0.126 0.100 The actual dimensions shall be subject to revision at the time of final engineering and shall be as per our datasheet submitted at the time of order -2-