QIBLA 1 ROOF PROJECTION LINE +0.00 GSL B STEEL HANDRAIL WITH PAINT FINISH (TYP) 2 3 CHEQUERED PLATE STEP & LANDING ON METAL SUPPORT WITH PAINT FINISH (TYP) +0.00 GSL 4 +0.00 GSL A TOILET W1 W5 W1 +0.710 FFL G23 W1 +0.710 FFL W3 W2 TOILET W1 W5 W1 +0.710 FFL G19 W4 W3 W2 TOILET W1 W5 W1 G15 W4 W3 W2 NOTES: W1 GENERAL NOTES: LIVING&PANTRY G24 LIVING&PANTRY G20 BEDROOM G21 W3 LOBBY LOBBY +0.710 FFL G22 G17 LOBBY +0.710 FFL G18 1 - ALL DIMENSIONS ARE IN MILLIMETERS, ALL DIMENSIONS SHOULD BE VERIFIED ON SITE AND APPROVED BY THE ENGINEER. BEDROOM LIVING&PANTRY G16 BEDROOM W3 G13 W3 +0.710 FFL 2 - ALL DRAWINGS SHOULD BE READ IN CONJUNCTION WITH OTHER RELEVANT ARCHITECTURAL, STRUCTURAL, MECHANICAL, ELECTRICAL, ROADS, INFRASTRUCTURE AND SPECIAL SYSTEMS DRAWINGS AND ALL ELECTRICAL AND SPECIAL SYSTEMS DRAWINGS AND ALL RELEVANT SECTIONS OF THE SPECIFICATIONS. G14 2 B BEDROOM LOBBY W4 G04 G02 W3 LIVING&PANTRY G01 W4 G06 +0.710 FFL BEDROOM LOBBY W4 LIVING&PANTRY G05 G08 W3 W4 G10 +0.710 FFL LIVING&PANTRY G09 +0.710 FFL BEDROOM LOBBY W4 G12 W3 W4 +0.710 FFL 3 - UNLESS OTHERWISE INDICATED,LEVELS ARE IN METERS (m) AND ANGLES ARE IN DEGREES. +0.710 FFL 4 - DRAWINGS ARE NOT TO BE SCALED, WRITTEN DIMENSIONS SHOULD BE FOLLOWED. PANTRY W1 +0.710 FFL W2 W3 W4 W2 W3 TOILET W1 G03 W4 W2 W3 TOILET W5 W1 W1 G07 W5 5 - THIS DRAWING SHOULD BE READ IN CONJUNCTION WITH ARICHITECTURE SCHEDULE DRAWING FOR DOOR SERIAL NUMBER. W1 TOILET W1 W1 G11 W5 W1 C ROOF PROJECTION LINE +0.00 GSL +0.00 GSL +0.00 GSL 1 PLANS SHEET NOTES: A 1 2 3 1. 2. FGL FFL FPL FCL = = = = 0.000 (FIXED GROUND LEVEL) FINISHED FLOOR LEVEL. FINISH PAVEMENT LEVEL FINISH CEILING LEVEL 3. FOR ALL EXTERNAL LEVELS, SLOPES, FINISHES, DIMENSIONS, ETC.., REFER TO LANDSCAPE & ROADS DRAWINGS. 4. FOR INTERNAL FINISHES, REFER TO FINISHING SCHEDULES. TOC = TOP OF CONCRETE TOPR = TOP OF PARAPET 4 0m 2m 6m 4m 8m 10m VISUAL SCALE 1:100 @ A1 L . EV 0 46 B . +3 A 0 R T. 7 .6 +3 2 B 1.ALL DIMENSIONS ARE IN MILLIMETER UNLESS OTHERWISE NOTED. 2.CONDUIT QTY. SHOWN IN DRAWING IS TENTATIVE, IT MAY VARY. L 0 46 . EV . +3 C A 1 EXTERNAL SIDE DRY SIDE DETAIL W1 WET SIDE WET SIDE 9+9mm X-TYPE FIRE RATED CEMENT BOARD WITH WEATHER RESISTANCE PAINT FINISH 16mm FR & MR GYPSUM BOARD WITH PAINT FINISH LGS WALL WET SIDE DRY SIDE DRY SIDE DRY SIDE EXTERNAL SIDE WET SIDE 16mm FIRE RATED GYPSUM BOARD WITH PAINT FINISH 9+9mm X-TYPE FIRE RATED CEMENT BOARD WITH WEATHER RESISTANCE PAINT FINISH LGS WALL 16mm FR & MR GYPSUM BOARD WITH PAINT FINISH +CERAMIC TILES UPTO CEILING LGS WALL LGS WALL LGS WALL 100mm FIBERGLASS INSULATION 50mm FIBERGLASS INSULATION 50mm FIBERGLASS INSULATION 50mm FIBERGLASS INSULATION 100mm FIBERGLASS INSULATION 16mm FIRE RATED GYPSUM BOARD WITH PAINT FINISH 16mm FR & MR GYPSUM BOARD WITH PAINT FINISH +CERAMIC TILES UPTO CEILING 16mm FIRE RATED GYPSUM BOARD WITH PAINT FINISH 16mm FIRE RATED GYPSUM BOARD WITH PAINT FINISH 16mm FR & MR GYPSUM BOARD WITH PAINT FINISH +CERAMIC TILES UPTO CEILING DETAIL W2 DETAIL W3 DETAIL W4 DETAIL W5 CLIENT: MONITORING COMPLIANCE CONSULTANT DESIGN CONSULTANT: CONTRACTOR: PETRORAQ Engineering Co. Ltd. PETRORAQ Engineering Co. Ltd.