WIREMOLD
CM SERIES™ COMMUNICATION MODULES
Wiremold® CM Series™ Communication Modules provide a variety of unloaded
modules to accept devices from other manufacturers. These open system modules
provide a flexible and aesthetically pleasing way to connect communication cabling
at the point-of-use.
CODE REFERENCE
cULus Listed Communication
Circuit Accessories:
File E145222 Guide DUXR.
Meets Article 800 of NEC.
Meets Article 60-308 of CEC.
CM Series Communication Modules Ordering Information
PART NUMBERS:
PART NUMBERS:
CM2-U1KEYA-WH (White)
CM2-U1KEYA-GY (Light Gray)
CM2-U1KEYA-BK (Black)
CM2-U1KEYA-G (Gray)
CM2-U1ATT-WH (White)
CM2-U1ATT-GY (Light Gray)
CM2-U1ATT-BK (Black)
CM2-U1ATT-G (Gray)
Accepts keystone jacks with a latching
area of 0.58" x 0.76" [14.7mm x 19.3 mm].
Accepts both M-series jacks and LC
fiber adapters.
2A Dual Flushmount Unloaded Keystone Module
PART NUMBERS:
COLOR OPTIONS
2A Single Systimax (Avaya) Unloaded Module
2A Single Systimax (Avaya) Unloaded Module
PART NUMBERS:
CM2-U2KEYA-WH (White)
CM2-U2KEYA-GY (Light Gray)
CM2-U2KEYA-BK (Black)
CM2-U2KEYA-G (Gray)
CM2-U2ATT-WH (White)
CM2-U2ATT-GY (Light Gray)
CM2-U2ATT-BK (Black)
CM2-U2ATT-G (Gray)
Accepts keystone jacks with a latching
area of 0.58" x 0.76" [14.7mm x 19.3 mm].
Accepts both M-series jacks and LC
fiber adapters.
CM Series™ Communication Modules standard color is ivory. For other
colors, add one of the following suffixes: “-WH” for white, “-GY” for
light gray (matches aluminum and nonmetallic products), “-BK” for
black, or “-G” for gray (matches Wiremold gray steel products).
WWW.LEGRAND.US/WIREMOLD
COMMUNICATIONS CONNECTIVITY
2A Single Flushmount Unloaded Keystone Module
19
WIREMOLD
CM SERIES™ COMMUNICATION MODULES
Ordering Information
CM Series Communication Modules Ordering Information (continued)
2A Single Flushmount NordX/CDT Unloaded Module
2A Dual Flushmount NordX/CDT Unloaded Module
PART NUMBERS:
PART NUMBERS:
CM2-U1NOR-WH (White)
CM2-U1NOR-GY (Light Gray)
CM2-U1NOR-BK (Black)
CM2-U1NOR-G (Gray)
CM2-U2NOR-WH (White)
CM2-U2NOR-GY (Light Gray)
CM2-U2NOR-BK (Black)
CM2-U2NOR-G (Gray)
Accepts MDVOFlex jacks and fiber
modules.
Accepts MDVOFlex jacks and fiber
modules.
2A Dual Unloaded ST Adapter Module
2A Unloaded Single AMP Netconnect Module
PART NUMBERS:
PART NUMBERS:
CM2-U2ST-WH (White)
CM2-U2ST-GY (Light Gray)
CM2-U2ST-BK (Black)
CM2-U2ST-G (Gray)
CM2-U2AMP-WH (White)
CM2-U2AMP-GY (Light Gray)
CM2-U2AMP-BK (Black)
CM2-U2AMP-G (Gray)
Accepts 2 ST adapters.
For mounting two AMP Netconnect
SL Series devices.
2A Unloaded Duplex SC Adapter Module
2A Blank Module
PART NUMBERS:
CM2-BL-WH (White)
CM2-BL-GY (Light Gray)
CM2-BL-BK (Black)
CM2-BL-G (Gray)
Accepts one SC adapter.
Required to fill unused openings.
2A Dual Flushmount Unloaded
Ortronics® TracJack Module
PART NUMBERS:
CM2-U2TJ-WH (White)
CM2-U2TJ-GY (Light Gray)
CM2-U2TJ-BK (Black)
CM2-U2TJ-G (Gray)
COMMUNICATIONS CONNECTIVITY
PART NUMBERS:
CM2-U2SC-WH (White)
CM2-U2SC-GY (Light Gray)
CM2-U2SC-BK (Black)
CM2-U2SC-G (Gray)
For mounting two Ortronics®
TracJack devices.
20
WWW.LEGRAND.US/WIREMOLD
2A SVGA Module
PART NUMBERS:
CM2-U2SVGA-WH (White)
CM2-U2SVGA-GY (Light Gray)
CM2-U2SVGA-BK (Black)
CM2-U2SVGA-G (Gray)
Accepts one SVGA connector.
WIREMOLD
5400 SERIES™ RACEWAY
Installation Details
Access 5400 Series Raceways Installation Details
1. Mount raceway base to wall by
using appropriate screws. Use
two screws every 18" [457mm]
using the ribs on the outermost
compartments of the raceway as
guides.
6. Snap 5450T Bracket to raceway
base, engage sidewall first then
divider side. Install Wiremold
Open System communication
modules, Ortronics® TracJack
or Series II inserts, or Pass
& Seymour® Activate Series
inserts, or 5507 Faceplates.
Snap raceway cover to base
and finish with 5450T Trim
Plate (engaging raceway
sidewall first then
divider side).
5400TB
18"
[457mm]
2. Place the 5400TWC Wire Clips
in base as shown to contain the
wires in place while installing.
5450T
5400TWC
5450T
3. Slide the 5406A and 5406T Seam
Covers on the uninstalled section
of raceway cover as shown; snap
cover to the base overlapping
the seam cover over the
installed section. 5406TB
Base Seam Clip used for
base seams.
5406TB
5400C
NONMETALLIC RACEWAY
5406A
7. End cap may be used as a blank
to cap off the raceway at the
end-of-run, or to feed wires
from a 1/2" trade size pipe;
punch out the proper KO. Mount
endcap to raceway base
using appropriate screws.
5410
8. Feeding raceway from conduit.
1. Line up base of the fitting with
the raceway base using the
5406T
tongues as guides.
5400TC
2. Fasten the base of the fitting
to the wall using screws.
4. Sequence for installing devices:
3. Remove the proper KO.
1. Snap bracket in raceway base.
4. Attach conduit using proper
2. Fasten devices to bracket.
fitting.
Communication devices snap
5. Feed the necessary cables.
onto bracket.
6. Slide the dividers (two provided)
3. Snap raceway covers to
into the mounting guides if
base, butting against
needed.
5450
bracket.
7. Snap the raceway cover on
4. Assemble trim ring.
the base.
5. Insert CM-EPLA or
8. Snap fitting cover onto the
NOTE: The 5400TB Base can
NOTE: Use blank plates to cover
S2-EPL, if required.
be rotated 90° to allow
any unused slots in bracket.
base using guiding keyslots
6. Install Wiremold
feed from back instead
in base.
Open System communication modules,
of side.
Ortronics® TracJack or Series II inserts, or Pass & Seymour®
Activate Series inserts required.
9. Mount flat elbow as shown; assemble
7. Or install 5507 Faceplates, if required.
raceway covers first, then elbow cover.
5. Install bracket to raceway base first,
mount to the wall with screws,
5450A3
and mount device. After
installing raceway cover,
snap box cover to bracket
and assemble faceplates.
Install Wiremold Open
System Communication
Modules, Ortronics® TracJack
or Series II inserts, or Pass &
Seymour® Activate Series Inserts, or 5507 Faceplates. Use
5407A3 with 5400TB to install three devices at one location.
156
WWW.LEGRAND.US/WIREMOLD
5411FO