Access Control | PAC 512 Two-Door Controller Series
Overview
The PAC 512 and the PAC 512IP control all aspects of two secure doors, with up to two card readers installed as entry and exit readers on each door. This includes
support for a door strike to lock and unlock the door and a door contact to detect the doors position. Each door also has a programmable auxiliary input that may be
used for alarm system integration, and an auxiliary output that enables a buzzer or strobe when security is breached or a door is left open. A tamper input enables the
monitoring of a enclosure door, and an override input that will release both doors. In the event of communication loss, the PAC 512 allows all local functionality to
continue until the server connection is restored.
With unprecedented scalability and flexibility, a Stanley PAC access control system can consist of just PAC 512-series access controllers, or PAC 512s managed by an
Access and Alarm Server (PAC 500). When operating in conjunction with a PAC 500, the PAC 512 serves as part of an integrated solution that can include both input
(PAC 520) and output (PAC 530) controllers, elevator control and sophisticated anti-passback capabilities providing a scalable solution for even the largest applications.
The Readykey™ Controller Retrofit Kit enables the conversion of existing K2100/K2200 controllers installed since 1990, to the new PAC 512 series.
Utilizing the existing enclosure and power supply, the kit replaces the legacy controller with new PAC512s. The kit preserves all the existing infrastructure investment
and maximizes the value of existing equipment by maintaining the power supply, cabling, readers and without re-enrolling cardholders.
Key Features
Controls up to two doors
Each door supports up to two K2000 Series/K3000-Series/Oneprox readers for entry and exit
or one Wiegand reader
Up to 20,000 onboard cardholder database and 16,000 event buffer
75,000 dynamic cardholder management support in conjunction PAC 500
20 system holidays with 20 start and stop dates and times
200 time profiles with up to 4,000 weekly periods
5,000 access groups, each with 2 time profiles and 2 area lists
One Form-C 3-Amp lock relay lock control per door
One programmable supervised or non-supervised Form-C 5-Amp auxillary relay per door*
One programmable supervised or non-supervised ancillary input per door*
Dedicated case tamper and door override to open all doors
Request to exit programmable supervised or non-supervised input per door
Door contact programmable supervised or non-supervised input per door
5V and 12V reader data
PAC 512IP includes a built-in RJ-45 100Mbps Ethernet connection
Local anti-passback
Area anti-passback and area usage in conjunction with PAC 500
Mantrap capability in conjunction with PAC 500
One-Touch installation test mode. This installer test facility enables the functionality
of each controller and its associated circuits to be tested locally at the door, by simply
pressing a single button without the need for a PC or programming
AC and battery status are monitored and reported
Non-volatile memory storage
Rechargeable lithium battery monitoring and status reporting
Lock sharing across door channels
Individual extended door access times (ADA compliance)
Downloadable firmware updates
DIN-Rail mounting for ease of installation (removable)
TM
TM
*
Can be independantly controlled in conjunction with PAC 500 Access & Alarm Server
7S-512IPB
READYKEY
™
COMPATIBLE
DOWNSTREAM COMMUNICATIONS:
TOTAL OF 24 CONTROLLERS
UPSTREAM COMMUNICATIONS:
RS-232 (PAC 512), TCP/IP (PAC 512IP)
or RS-485 (PAC 500)
DOOR
OVERRIDE
INPUT
AUXILLARY INPUT
(1 PER DOOR CHANNEL)
AUXILLARY OUTPUT
(1 PER DOOR CHANNEL)
PAC 512IP Mk. II
CASE
TAMPER
INPUT
DOOR CONTACT
DOOR CONTACT
STANLEY PAC 512IP
EXIT (OUT) READER
OR REX BUTTON
GROUND
1
2
3
4
5
6
7
8
9
*
0
#
ENTRY READER
P
S
U
INPUT: 10.5VDC TO 28VDC
ENTRY (IN) READER
DOOR LOCK
REQUESTTO-EXIT
+-
DOOR LOCK
LOCK POWER OUTPUT
- +
EXIT
12 OR 24V BATTERY INPUT
ENTRY
EXIT
ENTRY
DOOR TWO
DOOR ONE
CONTROLLER AND OPTIONS
7S-512
7S-512B
Stanley PAC 512 - Two Door Access Controller (DIN-Rail Mount)
Stanley PAC 512 - Two-Door Access Controller in a 13 x 13 in. metal cabinet with lock,
prewired with a single output 3A power supply/charger,12 or 24VDC selectable.
7S-512IP
7S-512IPB
Stanley PAC 512IP - Two Door Access Controller (DIN-Rail Mount)
Stanley PAC 512IP - Two-Door Access Controller in a 13 x 13 in. metal cabinet with lock,
prewired with a single output 3A power supply/charger,12 or 24VDC selectable.
7S-2KRETRO
Readykey K2100/K2200 Controller Retrofit Kit
7S-PSU3
7S-PSU7
Stanley 3A Power Supply/Charger, 12 or 24VDC Selectable (DIN-Rail Mount)
Stanley 7A Power Supply/Charger, 12 or 24VDC Selectable (DIN-Rail Mount)
SPECIFICATIONS
Primary Power
Input Power:
Event Memory and Clock Backup
Communication Ports
Ethernet (PAC 512IP only):
Dial-Up (PAC 512 only):
Downstream Ports:
Inputs
Tamper and Door Override:
Power Fail Monitors (MSTAT):
Door Configuration
Inputs Per Door
Door Contact, REX & Auxiliary Input:
Outputs Per Door
Relay outputs:
Reader Power
Reader Port Compatibility
Status LEDs
Wiring Requirements
Mechanical
DIN-Rail Unit Dimensions:
DIN-Rail Unit Weight:
Enclosure Dimensions:
Environmental
Temperature:
Humidity:
Approvals:
Warranty
The PAC 512 is for use in low voltage, power limited, class 2 circuits only
10.5VDC to 28VDC — 220mA maximum
3V Rechargeable Lithium Cell (Monitored and status reported) - 6 months memory retention when not powered
10/100Base-T Ethernet high-speed RJ-45 port
RS-232
RS-485, 32 local devices maximum
Programmable as supervised or unsupervised circuits, dedicated
Unsupervised, dedicated
Each door supports up to two K2000 Series/K3000-Series/Oneprox readers for entry and exit or one Wiegand reader
TM
Each programmable as normally open,or normally closed, supervised or unsupervised circuits
One Form-C 3 A at 30VDC relay for lock control with thermal fuse and one programmable Form-C 5 A at 30VDC auxiliary relay
Follows input voltage. Limited to 200 mA @ 12 VDC
PAC, Wiegand Data 1/Data 0 and Magstripe Clock/Data
RS-232, RS-485, Door 1, Door 2, LAN Status and System Status
RS-485: CAT5 or CAT 6 up to 3000ft or 22AWG cable up to 500ft total cable.
Reader Wire: 22AWG Unshielded and Stranded, up to 800 ft
H: 7.3" W: 5.1" D: 5.1"
14oz. nominal
H: 13" W: 13" D: 3.5"
Operating: 14F to 131°F Storage: 9F to 176F
0 to 90% RHNC
UL 294-listed, CE-marked and ROHS compliant
5-Year Limited Warranty
© Copyright 2017, Stanley Security Solutions, Inc. All Rights Reserved. The information contained herein is subject to change without notice. Stanley shall not be liable for technical or editorial errors or omissions contained
herein. Stanley, PAC, Stanley PAC, One-Touch are registered trademarks of Stanley Security Solutions, Inc. Readykey is a registered trademark of Stanley Security Solutions, Inc in the European Union,
UK and Australia and of Bosch Security Inc. in the USA. All other trademarks are the property of their owners. Rev. AJM1/17
Visit us at...
Download