Access Control | PAC 512 Two-Door Controller Series Overview The PAC 512 and the PAC 512IP control all aspects of two secure doors, with up to two card readers installed as entry and exit readers on each door. This includes support for a door strike to lock and unlock the door and a door contact to detect the doors position. Each door also has a programmable auxiliary input that may be used for alarm system integration, and an auxiliary output that enables a buzzer or strobe when security is breached or a door is left open. A tamper input enables the monitoring of a enclosure door, and an override input that will release both doors. In the event of communication loss, the PAC 512 allows all local functionality to continue until the server connection is restored. With unprecedented scalability and flexibility, a Stanley PAC access control system can consist of just PAC 512-series access controllers, or PAC 512s managed by an Access and Alarm Server (PAC 500). When operating in conjunction with a PAC 500, the PAC 512 serves as part of an integrated solution that can include both input (PAC 520) and output (PAC 530) controllers, elevator control and sophisticated anti-passback capabilities providing a scalable solution for even the largest applications. The Readykey™ Controller Retrofit Kit enables the conversion of existing K2100/K2200 controllers installed since 1990, to the new PAC 512 series. Utilizing the existing enclosure and power supply, the kit replaces the legacy controller with new PAC512s. The kit preserves all the existing infrastructure investment and maximizes the value of existing equipment by maintaining the power supply, cabling, readers and without re-enrolling cardholders. Key Features Controls up to two doors Each door supports up to two K2000 Series/K3000-Series/Oneprox readers for entry and exit or one Wiegand reader Up to 20,000 onboard cardholder database and 16,000 event buffer 75,000 dynamic cardholder management support in conjunction PAC 500 20 system holidays with 20 start and stop dates and times 200 time profiles with up to 4,000 weekly periods 5,000 access groups, each with 2 time profiles and 2 area lists One Form-C 3-Amp lock relay lock control per door One programmable supervised or non-supervised Form-C 5-Amp auxillary relay per door* One programmable supervised or non-supervised ancillary input per door* Dedicated case tamper and door override to open all doors Request to exit programmable supervised or non-supervised input per door Door contact programmable supervised or non-supervised input per door 5V and 12V reader data PAC 512IP includes a built-in RJ-45 100Mbps Ethernet connection Local anti-passback Area anti-passback and area usage in conjunction with PAC 500 Mantrap capability in conjunction with PAC 500 One-Touch installation test mode. This installer test facility enables the functionality of each controller and its associated circuits to be tested locally at the door, by simply pressing a single button without the need for a PC or programming AC and battery status are monitored and reported Non-volatile memory storage Rechargeable lithium battery monitoring and status reporting Lock sharing across door channels Individual extended door access times (ADA compliance) Downloadable firmware updates DIN-Rail mounting for ease of installation (removable) TM TM * Can be independantly controlled in conjunction with PAC 500 Access & Alarm Server 7S-512IPB READYKEY ™ COMPATIBLE DOWNSTREAM COMMUNICATIONS: TOTAL OF 24 CONTROLLERS UPSTREAM COMMUNICATIONS: RS-232 (PAC 512), TCP/IP (PAC 512IP) or RS-485 (PAC 500) DOOR OVERRIDE INPUT AUXILLARY INPUT (1 PER DOOR CHANNEL) AUXILLARY OUTPUT (1 PER DOOR CHANNEL) PAC 512IP Mk. II CASE TAMPER INPUT DOOR CONTACT DOOR CONTACT STANLEY PAC 512IP EXIT (OUT) READER OR REX BUTTON GROUND 1 2 3 4 5 6 7 8 9 * 0 # ENTRY READER P S U INPUT: 10.5VDC TO 28VDC ENTRY (IN) READER DOOR LOCK REQUESTTO-EXIT +- DOOR LOCK LOCK POWER OUTPUT - + EXIT 12 OR 24V BATTERY INPUT ENTRY EXIT ENTRY DOOR TWO DOOR ONE CONTROLLER AND OPTIONS 7S-512 7S-512B Stanley PAC 512 - Two Door Access Controller (DIN-Rail Mount) Stanley PAC 512 - Two-Door Access Controller in a 13 x 13 in. metal cabinet with lock, prewired with a single output 3A power supply/charger,12 or 24VDC selectable. 7S-512IP 7S-512IPB Stanley PAC 512IP - Two Door Access Controller (DIN-Rail Mount) Stanley PAC 512IP - Two-Door Access Controller in a 13 x 13 in. metal cabinet with lock, prewired with a single output 3A power supply/charger,12 or 24VDC selectable. 7S-2KRETRO Readykey K2100/K2200 Controller Retrofit Kit 7S-PSU3 7S-PSU7 Stanley 3A Power Supply/Charger, 12 or 24VDC Selectable (DIN-Rail Mount) Stanley 7A Power Supply/Charger, 12 or 24VDC Selectable (DIN-Rail Mount) SPECIFICATIONS Primary Power Input Power: Event Memory and Clock Backup Communication Ports Ethernet (PAC 512IP only): Dial-Up (PAC 512 only): Downstream Ports: Inputs Tamper and Door Override: Power Fail Monitors (MSTAT): Door Configuration Inputs Per Door Door Contact, REX & Auxiliary Input: Outputs Per Door Relay outputs: Reader Power Reader Port Compatibility Status LEDs Wiring Requirements Mechanical DIN-Rail Unit Dimensions: DIN-Rail Unit Weight: Enclosure Dimensions: Environmental Temperature: Humidity: Approvals: Warranty The PAC 512 is for use in low voltage, power limited, class 2 circuits only 10.5VDC to 28VDC — 220mA maximum 3V Rechargeable Lithium Cell (Monitored and status reported) - 6 months memory retention when not powered 10/100Base-T Ethernet high-speed RJ-45 port RS-232 RS-485, 32 local devices maximum Programmable as supervised or unsupervised circuits, dedicated Unsupervised, dedicated Each door supports up to two K2000 Series/K3000-Series/Oneprox readers for entry and exit or one Wiegand reader TM Each programmable as normally open,or normally closed, supervised or unsupervised circuits One Form-C 3 A at 30VDC relay for lock control with thermal fuse and one programmable Form-C 5 A at 30VDC auxiliary relay Follows input voltage. Limited to 200 mA @ 12 VDC PAC, Wiegand Data 1/Data 0 and Magstripe Clock/Data RS-232, RS-485, Door 1, Door 2, LAN Status and System Status RS-485: CAT5 or CAT 6 up to 3000ft or 22AWG cable up to 500ft total cable. Reader Wire: 22AWG Unshielded and Stranded, up to 800 ft H: 7.3" W: 5.1" D: 5.1" 14oz. nominal H: 13" W: 13" D: 3.5" Operating: 14F to 131°F Storage: 9F to 176F 0 to 90% RHNC UL 294-listed, CE-marked and ROHS compliant 5-Year Limited Warranty © Copyright 2017, Stanley Security Solutions, Inc. All Rights Reserved. The information contained herein is subject to change without notice. Stanley shall not be liable for technical or editorial errors or omissions contained herein. Stanley, PAC, Stanley PAC, One-Touch are registered trademarks of Stanley Security Solutions, Inc. Readykey is a registered trademark of Stanley Security Solutions, Inc in the European Union, UK and Australia and of Bosch Security Inc. in the USA. All other trademarks are the property of their owners. Rev. AJM1/17 Visit us at...